101
|
Coyle JP, Derk RC, Lindsley WG, Boots T, Blachere FM, Reynolds JS, McKinney WG, Sinsel EW, Lemons AR, Beezhold DH, Noti JD. Reduction of exposure to simulated respiratory aerosols using ventilation, physical distancing, and universal masking. INDOOR AIR 2022; 32:e12987. [PMID: 35225389 PMCID: PMC8988470 DOI: 10.1111/ina.12987] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Revised: 12/23/2021] [Accepted: 12/24/2021] [Indexed: 06/14/2023]
Abstract
To limit community spread of SARS-CoV-2, CDC recommends universal masking indoors, maintaining 1.8 m of physical distancing, adequate ventilation, and avoiding crowded indoor spaces. Several studies have examined the independent influence of each control strategy in mitigating transmission in isolation, yet controls are often implemented concomitantly within an indoor environment. To address the influence of physical distancing, universal masking, and ventilation on very fine respiratory droplets and aerosol particle exposure, a simulator that coughed and exhaled aerosols (the source) and a second breathing simulator (the recipient) were placed in an exposure chamber. When controlling for the other two mitigation strategies, universal masking with 3-ply cotton masks reduced exposure to 0.3-3 µm coughed and exhaled aerosol particles by >77% compared to unmasked tests, whereas physical distancing (0.9 or 1.8 m) significantly changed exposure to cough but not exhaled aerosols. The effectiveness of ventilation depended upon the respiratory activity, that is, coughing or breathing, as well as the duration of exposure time. Our results demonstrate that a layered mitigation strategy approach of administrative and engineering controls can reduce personal inhalation exposure to potentially infectious very fine respiratory droplets and aerosol particles within an indoor environment.
Collapse
Affiliation(s)
- Jayme P. Coyle
- Health Effects Laboratory DivisionCenters for Disease Control and PreventionNational Institute for Occupational Safety and HealthMorgantownWest VirginiaUSA
| | - Raymond C. Derk
- Health Effects Laboratory DivisionCenters for Disease Control and PreventionNational Institute for Occupational Safety and HealthMorgantownWest VirginiaUSA
| | - William G. Lindsley
- Health Effects Laboratory DivisionCenters for Disease Control and PreventionNational Institute for Occupational Safety and HealthMorgantownWest VirginiaUSA
| | - Theresa Boots
- Health Effects Laboratory DivisionCenters for Disease Control and PreventionNational Institute for Occupational Safety and HealthMorgantownWest VirginiaUSA
| | - Francoise M. Blachere
- Health Effects Laboratory DivisionCenters for Disease Control and PreventionNational Institute for Occupational Safety and HealthMorgantownWest VirginiaUSA
| | - Jeffrey S. Reynolds
- Health Effects Laboratory DivisionCenters for Disease Control and PreventionNational Institute for Occupational Safety and HealthMorgantownWest VirginiaUSA
| | - Walter G. McKinney
- Health Effects Laboratory DivisionCenters for Disease Control and PreventionNational Institute for Occupational Safety and HealthMorgantownWest VirginiaUSA
| | - Erik W. Sinsel
- Health Effects Laboratory DivisionCenters for Disease Control and PreventionNational Institute for Occupational Safety and HealthMorgantownWest VirginiaUSA
| | - Angela R. Lemons
- Health Effects Laboratory DivisionCenters for Disease Control and PreventionNational Institute for Occupational Safety and HealthMorgantownWest VirginiaUSA
| | - Donald H. Beezhold
- Health Effects Laboratory DivisionCenters for Disease Control and PreventionNational Institute for Occupational Safety and HealthMorgantownWest VirginiaUSA
| | - John D. Noti
- Health Effects Laboratory DivisionCenters for Disease Control and PreventionNational Institute for Occupational Safety and HealthMorgantownWest VirginiaUSA
| |
Collapse
|
102
|
Rehman I, Ali S, O’Brien C, Goodall C. Assessing the impact of FFP3 masks to oxygen saturation and pulse rate in the Oral Surgery department at the Glasgow Dental Hospital during the COVID-19 pandemic: an observational study. ORAL SURGERY 2022; 15:30-35. [PMID: 34548881 PMCID: PMC8447064 DOI: 10.1111/ors.12648] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/20/2021] [Revised: 05/06/2021] [Accepted: 06/23/2021] [Indexed: 12/01/2022]
Abstract
Aim The impact on physiological parameters and well-being from potential respiratory distress caused by FFP3 masks, particularly during extensive clinical sessions, has been widely speculated during the COVID-19 pandemic. This study aims to investigate the effect of FFP3 mask wear on clinicians' pulse rate and oxygen saturation. Material & Methods Clinical staff within the Oral Surgery department recorded their oxygen saturation (SpO2) and pulse rate prior to donning an FFP3 mask, prior to doffing FFP3 mask and after doffing FFP3 mask using a finger pulse oximeter for a two-week period in May-June 2020. The duration of wear, the session (AM/PM), the brand of mask and the presence of previous COVID-19 symptoms were also recorded. Results Twenty-eight data sets were collected from twelve participants (1M:11F). Of the FFP3 masks worn, nineteen (67.86%) were ARCOTM, eight (28.57%) were 3MTM masks and one (3.57%) was 3M+TM. At baseline, the mean SpO2 was 98.39% and the mean pulse rate was 72.11. Prior to mask removal, the mean SpO2 was 97.82% and the mean pulse rate was 70.04. At the end of the session, the mean SpO2 was 98.14% and the mean pulse rate was 69.54. The mean duration of wear was 150.34 min. Data sets were collected evenly across AM (14) and PM (14) sessions. Five participants (17.86%) reported previous COVID-19 symptoms. Conclusion The data demonstrated a mean reduction of 0.25% in oxygen saturation and 3.56% in pulse rate, following the use of an FFP3 mask. These changes in physiological parameters are not clinically significant and sessional use appears to be safe.
Collapse
Affiliation(s)
- Ilyaas Rehman
- Department of Oral SurgerySchool of Medicine Dentistry and NursingCollege of MVLSUniversity of GlasgowScotlandUK
| | - Sarah Ali
- Department of Oral SurgerySchool of Medicine Dentistry and NursingCollege of MVLSUniversity of GlasgowScotlandUK
| | - Conor O’Brien
- Department of Oral SurgerySchool of Medicine Dentistry and NursingCollege of MVLSUniversity of GlasgowScotlandUK
| | - Christine Goodall
- Department of Oral SurgerySchool of Medicine Dentistry and NursingCollege of MVLSUniversity of GlasgowScotlandUK
| |
Collapse
|
103
|
Parvez MK, Parveen S. Airborne transmission of SARS-CoV-2 disease (COVID-19). Future Virol 2022; 17:10.2217/fvl-2021-0324. [PMID: 35251292 PMCID: PMC8889901 DOI: 10.2217/fvl-2021-0324] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2021] [Accepted: 02/10/2022] [Indexed: 11/22/2022]
Affiliation(s)
- Mohammad K Parvez
- Department of Pharmacognosy, King Saud University College of Pharmacy, Riyadh, 11451, Saudi Arabia
| | - Shama Parveen
- Centre for Interdisciplinary Research in Basic Sciences, Jamia Millia Islamia Central University, New Delhi, 110025, India
| |
Collapse
|
104
|
Nguyen TT, Johnson GR, Bell SC, Knibbs LD. A Systematic Literature Review of Indoor Air Disinfection Techniques for Airborne Bacterial Respiratory Pathogens. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph19031197. [PMID: 35162224 PMCID: PMC8834760 DOI: 10.3390/ijerph19031197] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/05/2021] [Revised: 01/18/2022] [Accepted: 01/19/2022] [Indexed: 02/06/2023]
Abstract
Interrupting the transmission of airborne (<≈5 µm) respiratory pathogens indoors is not a new challenge, but it has attracted unprecedented interest due to the COVID-19 pandemic during 2020–2021. However, bacterial respiratory pathogens with known or potential airborne transmission account for an appreciable proportion of the communicable disease burden globally. We aimed to systematically review quantitative, laboratory-based studies of air disinfection techniques for airborne respiratory bacteria. Three databases (PubMed, Web of Science, Scopus) were searched, following PRISMA guidelines. A total of 9596 articles were identified, of which 517 were assessed in detail and of which 26 met the inclusion and quality assessment criteria. Seven air disinfection techniques, including UV-C light, filtration, and face masks, among others, were applied to 13 different bacterial pathogens. More than 80% of studies suggested that air disinfection techniques were more effective at inactivating or killing bacteria than the comparator or baseline condition. However, it was not possible to compare these techniques because of methodological heterogeneity and the relatively small number of the studies. Laboratory studies are useful for demonstrating proof-of-concept and performance under controlled conditions. However, the generalisability of their findings to person-to-person transmission in real-world settings is unclear for most of the pathogens and techniques we assessed.
Collapse
Affiliation(s)
- Thi Tham Nguyen
- School of Public Health, The University of Queensland, Herston, QLD 4006, Australia;
- Correspondence:
| | - Graham R. Johnson
- School of Earth and Atmospheric Sciences, Queensland University of Technology, Brisbane, QLD 4000, Australia;
| | - Scott C. Bell
- Children’s Health Research Centre, Faculty of Medicine, The University of Queensland, Brisbane, QLD 4101, Australia;
- Adult Cystic Fibrosis Centre, The Prince Charles Hospital, Chermside, QLD 4032, Australia
- Translational Research Institute, Brisbane, QLD 4102, Australia
| | - Luke D. Knibbs
- School of Public Health, The University of Queensland, Herston, QLD 4006, Australia;
- Faculty of Medicine and Health, School of Public Health, The University of Sydney, Sydney, NSW 2006, Australia
| |
Collapse
|
105
|
Wu J, Weng W, Shen L, Fu M. Transient and continuous effects of indoor human movement on nanoparticle concentrations in a sitting person's breathing zone. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 805:149970. [PMID: 34543798 DOI: 10.1016/j.scitotenv.2021.149970] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Revised: 08/19/2021] [Accepted: 08/24/2021] [Indexed: 06/13/2023]
Abstract
Particle concentration in a sitting person's breathing zone can be influenced by human movement around the person, and the transient and continuous effects may differ. In this study, a set of full-scale experiments was conducted to sample the nanoparticle concentration in the breathing zone of a sitting thermal breathing manikin (STBM). The transient fluctuation of the nanoparticle concentration was recorded continuously and analyzed. The results showed that when a manikin moved (at 1 m/s) past the STBM, the nanoparticle concentration in the STBM's breathing zone decreased and reached its lowest after the standing manikin had passed, decreasing 37.6 (±5.7) % compared with the peak value. The average concentration in the STBM's breathing zone during influence periods was 5.18 (±0.99) % less than that during non-influence Periods (NP). This finding reflected the fact that the transient inhalation (over several seconds) of the STBM may be reduced by manikin movement. On the other hand, the exposure of the STBM increased 2.88 (±1.24) % when there was a continuously moving manikin compared with the stable state in a 10-min observation. This finding may be explained by the fuller mix of indoor air and nanoparticles caused by manikin movement, as well as the increase of nanoparticle suspension time. The difference in the transient and continuous effects of the manikin movement on the STBM's exposure shows the importance of considering these effects separately in different scenarios.
Collapse
Affiliation(s)
- Jialin Wu
- Institute of Public Safety Research, Department of Engineering Physics, Tsinghua University, Beijing 100084, PR China; Beijing Key Laboratory of City Integrated Emergency Response Science, Tsinghua University, Beijing 100084, PR China
| | - Wenguo Weng
- Institute of Public Safety Research, Department of Engineering Physics, Tsinghua University, Beijing 100084, PR China; Beijing Key Laboratory of City Integrated Emergency Response Science, Tsinghua University, Beijing 100084, PR China.
| | - Liangchang Shen
- Institute of Public Safety Research, Department of Engineering Physics, Tsinghua University, Beijing 100084, PR China; Beijing Key Laboratory of City Integrated Emergency Response Science, Tsinghua University, Beijing 100084, PR China
| | - Ming Fu
- Anhui Province Key Laboratory of Human Safety, Hefei, Anhui Province 230601, PR China
| |
Collapse
|
106
|
Mohamadi F, Fazeli A. A Review on Applications of CFD Modeling in COVID-19 Pandemic. ARCHIVES OF COMPUTATIONAL METHODS IN ENGINEERING : STATE OF THE ART REVIEWS 2022; 29:3567-3586. [PMID: 35079217 PMCID: PMC8773396 DOI: 10.1007/s11831-021-09706-3] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/25/2021] [Accepted: 12/28/2021] [Indexed: 05/25/2023]
Abstract
COVID-19 pandemic has started a big challenge to the world health and economy during recent years. Many efforts were made to use the computation fluid dynamic (CFD) approach in this pandemic. CFD was used to understanding the airborne dispersion and transmission of this virus in different situations and buildings. The effect of the different conditions of the ventilation was studied by the CFD modeling to discuss preventing the COVID-19 transmission. Social distancing and using the facial masks were also modeled by the CFD approach to study the effect on reducing dispersion of the microdroplets containing the virus. Most of these recent applications of the CFD were reviewed for COVID-19 in this article. Special applications of the CFD modeling such as COVID-19 microfluidic biosensors, and COVID-19 inactivation using UV radiation were also reviewed in this research. The main findings of each research were also summarized in a table to answer critical questions about the effectiveness levels of applying the COVID-19 health protocols. CFD applications for modeling of COVID-19 dispersion in an airplane cabin, an elevator, a small classroom, a supermarket, an operating room of a hospital, a restaurant, a hospital waiting room, and a children's recovery room in a hospital were discussed briefly in different scenarios. CFD modeling for studying the effect of social distancing with different spaces, using and not using facial masks, difference of sneezing and coughing, different inlet/outlet ventilation layouts, combining air-conditioning and sanitizing machine, and using general or local air-conditioning systems were reviewed.
Collapse
Affiliation(s)
- Fateme Mohamadi
- Department of Chemical Engineering, Caspian Faculty of Engineering, College of Engineering, University of Tehran, Tehran, Iran
| | - Ali Fazeli
- Department of Chemical Engineering, Caspian Faculty of Engineering, College of Engineering, University of Tehran, Tehran, Iran
| |
Collapse
|
107
|
Peng Z, Pineda Rojas A, Kropff E, Bahnfleth W, Buonanno G, Dancer S, Kurnitski J, Li Y, Loomans M, Marr L, Morawska L, Nazaroff W, Noakes C, Querol X, Sekhar C, Tellier R, Greenhalgh T, Bourouiba L, Boerstra A, Tang J, Miller S, Jimenez J. Practical Indicators for Risk of Airborne Transmission in Shared Indoor Environments and Their Application to COVID-19 Outbreaks. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2022; 56:1125-1137. [PMID: 34985868 PMCID: PMC7617205 DOI: 10.1021/acs.est.1c06531] [Citation(s) in RCA: 77] [Impact Index Per Article: 25.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
Some infectious diseases, including COVID-19, can undergo airborne transmission. This may happen at close proximity, but as time indoors increases, infections can occur in shared room air despite distancing. We propose two indicators of infection risk for this situation, that is, relative risk parameter (Hr) and risk parameter (H). They combine the key factors that control airborne disease transmission indoors: virus-containing aerosol generation rate, breathing flow rate, masking and its quality, ventilation and aerosol-removal rates, number of occupants, and duration of exposure. COVID-19 outbreaks show a clear trend that is consistent with airborne infection and enable recommendations to minimize transmission risk. Transmission in typical prepandemic indoor spaces is highly sensitive to mitigation efforts. Previous outbreaks of measles, influenza, and tuberculosis were also assessed. Measles outbreaks occur at much lower risk parameter values than COVID-19, while tuberculosis outbreaks are observed at higher risk parameter values. Because both diseases are accepted as airborne, the fact that COVID-19 is less contagious than measles does not rule out airborne transmission. It is important that future outbreak reports include information on masking, ventilation and aerosol-removal rates, number of occupants, and duration of exposure, to investigate airborne transmission.
Collapse
Affiliation(s)
- Z. Peng
- Dept. of Chemistry and CIRES, University of Colorado, Boulder, Colorado 80309, United States
| | - A.L. Pineda Rojas
- CIMA, UMI-IFAECI/CNRS, FCEyN, Universidad de Buenos Aires—YUBA/CONICET, Buenos Aires C1428EGA, Argentina
| | - E. Kropff
- Leloir Institute—IIBBA/CONICET, CBA, Buenos Aires C1405BWE, Argentina
| | - W. Bahnfleth
- Dept. of Architectural Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
| | - G. Buonanno
- Dept. of Civil and Mechanical Engineering, University of Cassino and Southern Lazio, Cassino 03043, Italy
| | - S.J. Dancer
- Dept. of Microbiology, NHS Lanarkshire, Glasgow, Scotland G75 8RG, U.K.; School of Applied Sciences, Edinburgh Napier University, Edinburgh, Scotland EH11 4BN, U.K
| | - J. Kurnitski
- REHVA Technology and Research Committee, Tallinn University of Technology, Tallinn 19086, Estonia
| | - Y. Li
- Dept. of Mechanical Engineering, The University of Hong Kong, Hong Kong 999077, China
| | - M.G.L.C. Loomans
- Dept. of the Built Environment, Eindhoven University of Technology, Eindhoven 5612 AZ, The Netherlands
| | - L.C. Marr
- Dept. of Civil and Environmental Engineering, Virginia Tech, Blacksburg, Virginia 24061, United States
| | - L. Morawska
- International Laboratory for Air Quality and Health, Queensland University of Technology, Brisbane, Queensland 4001, Australia
| | - W. Nazaroff
- Dept. of Civil and Environmental Engineering, University of California, Berkeley, California 94720, United States
| | - C. Noakes
- School of Civil Engineering, University of Leeds, Leeds LS2 9JT, U.K
| | - X. Querol
- Institute of Environmental Assessment and Water Research, IDAEA, Spanish Research Council, CSIC, Barcelona 08034, Spain
| | - C. Sekhar
- Dept. of the Built Environment, National University of Singapore, 117566, Singapore
| | - R. Tellier
- Dept. of Medicine, McGill University and McGill University Health Centre, Montreal, Québec H4A 3J1, Canada
| | - T. Greenhalgh
- Nuffield Dept. of Primary Care Health Sciences, University of Oxford, Oxford OX2 6GG, U.K
| | - L. Bourouiba
- The Fluid Dynamics of Disease Transmission Laboratory, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
| | - A. Boerstra
- REHVA (Federation of European Heating, Ventilation and Air Conditioning Associations), BBA Binnenmilieu, The Hague 2501 CJ, The Netherlands
| | - J.W. Tang
- Dept. of Respiratory Sciences, University of Leicester, Leicester LE1 7RH, U.K
| | - S.L. Miller
- Dept. of Mechanical Engineering, University of Colorado, Boulder, Colorado 80309, United States
| | - J.L. Jimenez
- Corresponding Author J.L. Jimenez - Dept. of Chemistry and CIRES, University of Colorado, Boulder, Colorado 80309, United States;
| |
Collapse
|
108
|
Chen W, Qian H, Zhang N, Liu F, Liu L, Li Y. Extended short-range airborne transmission of respiratory infections. JOURNAL OF HAZARDOUS MATERIALS 2022; 422:126837. [PMID: 34399209 PMCID: PMC8342890 DOI: 10.1016/j.jhazmat.2021.126837] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/17/2021] [Revised: 08/03/2021] [Accepted: 08/04/2021] [Indexed: 05/09/2023]
Abstract
Debate and scientific inquiries regarding airborne transmission of respiratory infections such as COVID-19 and influenza continue. Health authorities including the WHO and the US CDC have recognized the airborne transmission of COVID-19 in specific settings, although the ventilation requirements remain to be determined. In this work we consider the long-range airborne transmission as an extended short-range airborne route, which reconciles the link between short- and long-range airborne routes. The effective short-range distance is defined as the distance in short range at which long-range route has the same volumetric exposure value as that due to short-range route. Our data show that a decrease in ventilation rate or room volume per person, or an increase in the ratio of the number of infected to susceptible people reduces the effective short-range distance. In a normal breathing scenario with one out of five people infected and a room volume of 12 m3 per person to ensure an effective short-range distance of 1.5 m, a ventilation rate of 10 L/s per person is needed for a duration of 2 h. Our results suggest that effective environmental prevention strategies for respiratory infections require appropriate increases in the ventilation rate while maintaining a sufficiently low occupancy. PRACTICAL IMPLICATIONS: Demonstration of the long-range airborne route as an extended short-range airborne route suggests the significant role played by building ventilation in respiratory infection exposure. The reconciliation of short- and long-range airborne transmission suggests that the commonly observed dominance of close-contact transmission is a probable evidence of short-range airborne transmission, following a separate earlier study that revealed the relative insignificance of large droplet transmission in comparison with the short-range airborne-route. Existing ventilation standards do not account for respiratory infection control, and this study presents a possible approach to account for infection under new ventilation standards.
Collapse
Affiliation(s)
- Wenzhao Chen
- Department of Mechanical Engineering, The University of Hong Kong, Pokfulam Road, Hong Kong, China
| | - Hua Qian
- School of Energy and Environment, Southeast University, Nanjing, China
| | - Nan Zhang
- Beijing Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing, China
| | - Fan Liu
- School of Energy and Environment, Southeast University, Nanjing, China
| | - Li Liu
- School of Architecture, Tsinghua University, Beijing, China
| | - Yuguo Li
- Department of Mechanical Engineering, The University of Hong Kong, Pokfulam Road, Hong Kong, China.
| |
Collapse
|
109
|
Parhizkar H, Dietz L, Olsen-Martinez A, Horve PF, Barnatan L, Northcutt D, Van Den Wymelenberg KG. Quantifying environmental mitigation of aerosol viral load in a controlled chamber with participants diagnosed with COVID-19. Clin Infect Dis 2022; 75:e174-e184. [PMID: 34996097 PMCID: PMC8755398 DOI: 10.1093/cid/ciac006] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2021] [Indexed: 12/16/2022] Open
Abstract
Background Several studies indicate that COVID-19 is primarily transmitted within indoor spaces. Therefore, environmental characterization of SARS-CoV-2 viral load with respect to human activity, building parameters, and environmental mitigation strategies is critical to combat disease transmission. Methods We recruited 11 participants diagnosed with COVID-19 to individually occupy a controlled chamber and conduct specified physical activities under a range of environmental conditions; we collected human and environmental samples over a period of three days for each participant. Results Here we show that increased viral load, measured by lower RNA cycle threshold (CT) values, in nasal samples is associated with higher viral loads in environmental aerosols and on surfaces captured in both the near field (1.2 m) and far field (3.5 m). We also found that aerosol viral load in far field is correlated with the number of particles within the range of 1 µm -2.5 µm. Furthermore, we found that increased ventilation and filtration significantly reduced aerosol and surface viral loads, while higher relative humidity resulted in lower aerosol and higher surface viral load, consistent with an increased rate of particle deposition at higher relative humidity. Data from near field aerosol trials with high expiratory activities suggest that respiratory particles of smaller sizes (0.3 µm -1 µm) best characterize the variance of near field aerosol viral load. Conclusions Our findings indicate that building operation practices such as ventilation, filtration, and humidification substantially reduce the environmental aerosol viral load, and therefore inhalation dose, and should be prioritized to improve building health and safety.
Collapse
Affiliation(s)
- Hooman Parhizkar
- Institute for Health and the Built Environment, University of Oregon, Portland, OR, United States
- Energy Studies in Buildings Laboratory, University of Oregon, Eugene, OR, United States
| | - Leslie Dietz
- Institute for Health and the Built Environment, University of Oregon, Portland, OR, United States
- Biology and the Built Environment Center, University of Oregon, Eugene, OR, United States
| | - Andreas Olsen-Martinez
- Institute for Health and the Built Environment, University of Oregon, Portland, OR, United States
- Biology and the Built Environment Center, University of Oregon, Eugene, OR, United States
| | - Patrick F Horve
- Institute for Health and the Built Environment, University of Oregon, Portland, OR, United States
- Biology and the Built Environment Center, University of Oregon, Eugene, OR, United States
- Institute of Molecular Biology, University of Oregon, Eugene, OR, United States
| | - Liliana Barnatan
- Biology and the Built Environment Center, University of Oregon, Eugene, OR, United States
| | - Dale Northcutt
- Institute for Health and the Built Environment, University of Oregon, Portland, OR, United States
- Energy Studies in Buildings Laboratory, University of Oregon, Eugene, OR, United States
| | - Kevin G Van Den Wymelenberg
- Institute for Health and the Built Environment, University of Oregon, Portland, OR, United States
- Energy Studies in Buildings Laboratory, University of Oregon, Eugene, OR, United States
- Biology and the Built Environment Center, University of Oregon, Eugene, OR, United States
- Corresponding Author: Kevin G. Van Den Wymelenberg, , Biology and the Built Environment Center, University of Oregon, Eugene, OR, United States, 97403, Energy Studies in Buildings Laboratory, University of Oregon, Eugene, OR, United States, 97403, Institute for Health and the Built Environment, University of Oregon, Portland, OR, United States, 97209
| |
Collapse
|
110
|
Berry G, Parsons A, Morgan M, Rickert J, Cho H. A review of methods to reduce the probability of the airborne spread of COVID-19 in ventilation systems and enclosed spaces. ENVIRONMENTAL RESEARCH 2022; 203:111765. [PMID: 34331921 PMCID: PMC8317458 DOI: 10.1016/j.envres.2021.111765] [Citation(s) in RCA: 45] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/24/2021] [Revised: 07/22/2021] [Accepted: 07/23/2021] [Indexed: 05/19/2023]
Abstract
COVID-19 forced the human population to rethink its way of living. The threat posed by the potential spread of the virus via an airborne transmission mode through ventilation systems in buildings and enclosed spaces has been recognized as a major concern. To mitigate this threat, researchers have explored different technologies and methods that can remove or decrease the concentration of the virus in ventilation systems and enclosed spaces. Although many technologies and methods have already been researched, some are currently available on the market, but their effectiveness and safety concerns have not been fully investigated. To acquire a broader view and collective perspective of the current research and development status, this paper discusses a comprehensive review of various workable technologies and methods to combat airborne viruses, e.g., COVID-19, in ventilation systems and enclosed spaces. These technologies and methods include an increase in ventilation, high-efficiency air filtration, ionization of the air, environmental condition control, ultraviolet germicidal irradiation, non-thermal plasma and reactive oxygen species, filter coatings, chemical disinfectants, and heat inactivation. Research gaps have been identified and discussed, and recommendations for applying such technologies and methods have also been provided in this article.
Collapse
Affiliation(s)
- Gentry Berry
- Institute for Clean Energy Technology, Mississippi State University, 205 Research Blvd, Starkville, MS, 39759, USA
| | - Adam Parsons
- Institute for Clean Energy Technology, Mississippi State University, 205 Research Blvd, Starkville, MS, 39759, USA
| | - Matthew Morgan
- Institute for Clean Energy Technology, Mississippi State University, 205 Research Blvd, Starkville, MS, 39759, USA
| | - Jaime Rickert
- Institute for Clean Energy Technology, Mississippi State University, 205 Research Blvd, Starkville, MS, 39759, USA
| | - Heejin Cho
- Institute for Clean Energy Technology, Mississippi State University, 205 Research Blvd, Starkville, MS, 39759, USA.
| |
Collapse
|
111
|
Beaussier M, Vanoli E, Zadegan F, Peray H, Bezian E, Jilesen J, Gandveau G, Gayraud JM. Aerodynamic analysis of hospital ventilation according to seasonal variations. A simulation approach to prevent airborne viral transmission pathway during Covid-19 pandemic. ENVIRONMENT INTERNATIONAL 2022; 158:106872. [PMID: 34547639 PMCID: PMC8443368 DOI: 10.1016/j.envint.2021.106872] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Revised: 09/07/2021] [Accepted: 09/07/2021] [Indexed: 06/13/2023]
Abstract
During the Covid-19 pandemic, location of the SARS-CoV-2 infected patients inside the hospital is a major issue to prevent viral cross-transmission. The objective of this study was to evaluate the risk of contamination through aerosol by using a global approach of the multiple environmental parameters to simulate, including seasonal context. A computational fluid dynamic (CFD) simulation based on the Lattice Boltzmann Method approach was used to predict airflow on the entire floor of a private hospital in Paris. The risk of contamination outside the rooms was evaluated by using a water vapor mass fraction tracker. Finally, the air contamination was estimated by a "cough model" producing several punctual emissions of contaminated air from potentially infected patients. In a winter configuration, the simulation showed a well-balanced ventilation on the floor and especially inside the rooms. After cough emissions from COVID-positive rooms, no significant contamination was observed in the circulation area, public waiting space and nurse office. On the contrary, in a summer configuration, the temperature difference due to the impact of the sun radiation between both sides of the building created additional air transport increasing the contamination risk in neighboring rooms and public spaces. Airborne spread was limited to rooms during winter conditions. On the contrary, during summer conditions, market airflow with potentially contaminated air coming from rooms located on the side of the building exposed to solar radiation was evidenced. These observations have implications to locate infected patients inside the building and for the conception of future health care structures.
Collapse
Affiliation(s)
- Marc Beaussier
- Institut Mutualiste Montsouris, 42 Bd Jourdan, 75014 Paris, France.
| | - Emmanuel Vanoli
- Institut Mutualiste Montsouris, 42 Bd Jourdan, 75014 Paris, France
| | - Frédéric Zadegan
- Institut Mutualiste Montsouris, 42 Bd Jourdan, 75014 Paris, France
| | - Herve Peray
- Institut Mutualiste Montsouris, 42 Bd Jourdan, 75014 Paris, France
| | - Elodie Bezian
- Institut Mutualiste Montsouris, 42 Bd Jourdan, 75014 Paris, France
| | - Jonathan Jilesen
- Institut Mutualiste Montsouris, 42 Bd Jourdan, 75014 Paris, France
| | | | | |
Collapse
|
112
|
Mckeen P, Liao Z. The influence of airtightness on contaminant spread in MURBs in cold climates. BUILDING SIMULATION 2022; 15:249-264. [PMID: 34025908 PMCID: PMC8121637 DOI: 10.1007/s12273-021-0787-6] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/12/2020] [Revised: 01/27/2021] [Accepted: 02/18/2021] [Indexed: 05/05/2023]
Abstract
Tall buildings in cold climates have unique challenges in maintaining indoor air quality due to stack effect. During the heating season, interior air buoyancy creates large pressure differentials in vertical shafts that can drive airflow from lower floors into upper floors. This pressure differential can result in the spread of contaminants throughout a building. Most recently, concern over COVID-19 has increased attention to the potential spread of airborne diseases in densely populated buildings. For many multi-unit residential buildings, suite ventilation has traditionally relied upon fresh air supplied through a mechanically pressurized corridor. In cold climates, large pressure differentials created by stack-effect can reduce the effectiveness of this approach. Multizone and CFD simulations are employed to analyze airflow and contaminant spread due to stack effect. Simulations are conducted on an idealized model of a 10-storey building using a range of experimentally derived airtightness parameters. Simulations demonstrate stack effect can reduce corridor ventilation to suites and even reverse the airflow for leakier buildings. Reduced airflow to suites can result in the accumulation of contaminants. Reversal of the airflow can allow contaminants from a suite to spread throughout the building. Contaminant spread is illustrated as a function of mechanical ventilation, building airtightness, and ambient temperatures. Strategies to reduce the influence of stack effect on mechanically pressurized corridors are discussed.
Collapse
Affiliation(s)
- Philip Mckeen
- Department of Architectural Science, Ryerson University, Toronto, M5B 2K3 Canada
| | - Zaiyi Liao
- Department of Architectural Science, Ryerson University, Toronto, M5B 2K3 Canada
| |
Collapse
|
113
|
McNeill VF, Corsi R, Huffman JA, King C, Klein R, Lamore M, Maeng DY, Miller SL, Lee Ng N, Olsiewski P, Godri Pollitt KJ, Segalman R, Sessions A, Squires T, Westgate S. Room-level ventilation in schools and universities. ATMOSPHERIC ENVIRONMENT: X 2022; 13:100152. [PMID: 35098105 PMCID: PMC8789458 DOI: 10.1016/j.aeaoa.2022.100152] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/10/2021] [Revised: 01/13/2022] [Accepted: 01/16/2022] [Indexed: 05/09/2023]
Abstract
Ventilation is of primary concern for maintaining healthy indoor air quality and reducing the spread of airborne infectious disease, including COVID-19. In addition to building-level guidelines, increased attention is being placed on room-level ventilation. However, for many universities and schools, ventilation data on a room-by-room basis are not available for classrooms and other key spaces. We present an overview of approaches for measuring ventilation along with their advantages and disadvantages. We also present data from recent case studies for a variety of institutions across the United States, with various building ages, types, locations, and climates, highlighting their commonalities and differences, and examples of the use of this data to support decision making.
Collapse
Affiliation(s)
- V Faye McNeill
- Department of Chemical Engineering, Columbia University, New York, NY, 10027, USA
- Department of Earth and Environmental Sciences, Columbia University, New York, NY, 10027, USA
| | - Richard Corsi
- College of Engineering, University of California, Davis, CA, 95616, USA
| | - J Alex Huffman
- Department of Chemistry and Biochemistry, University of Denver, Denver, CO, 80208, USA
| | - Cathleen King
- Environmental Health and Safety, Yale University, New Haven, CT, 06520, USA
| | - Robert Klein
- Occupational Health & Environmental Medicine, Yale School of Medicine, New Haven, CT, 06520, USA
- Coastal Safety, LLC, Clinton, CT, 06413, USA
| | - Michael Lamore
- Facilities Utilities and Engineering, Yale University, New Haven, CT, 06520, USA
| | - Do Young Maeng
- Department of Chemical Engineering, Columbia University, New York, NY, 10027, USA
| | - Shelly L Miller
- Department of Mechanical Engineering, University of Colorado, Boulder, Boulder, CO, 80309, USA
| | - Nga Lee Ng
- School of Chemical and Biomolecular Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA
- School of Earth and Atmospheric Sciences, Georgia Institute of Technology, Atlanta, GA, 30332, USA
- School of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA
| | - Paula Olsiewski
- Center for Health Security, Johns Hopkins University, Baltimore, MD, 21202, USA
| | - Krystal J Godri Pollitt
- Department of Environmental Health Sciences, Yale School of Public Health, New Haven, CT, 06520, USA
- Department of Chemical and Environmental Engineering, Yale School of Engineering and Applied Science, New Haven, CT, 06511, USA
| | - Rachel Segalman
- Department of Chemical Engineering, University of California, Santa Barbara, Santa Barbara, CA, 93106, USA
- Department of Materials, University of California, Santa Barbara, Santa Barbara, CA, 93106, USA
| | - Alex Sessions
- Department of Geology and Planetary Sciences, California Institute of Technology, Pasadena, CA, 91125, USA
| | - Todd Squires
- Department of Chemical Engineering, University of California, Santa Barbara, Santa Barbara, CA, 93106, USA
| | - Sabrina Westgate
- School of Chemical and Biomolecular Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA
| |
Collapse
|
114
|
Nazaroff WW. Indoor aerosol science aspects of SARS-CoV-2 transmission. INDOOR AIR 2022; 32:e12970. [PMID: 34873752 DOI: 10.1111/ina.12970] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/02/2021] [Revised: 11/17/2021] [Accepted: 11/26/2021] [Indexed: 05/04/2023]
Abstract
Knowledge about person-to-person transmission of SARS-CoV-2 is reviewed, emphasizing three components: emission of virus-containing particles and drops from infectious persons; transport and fate of such emissions indoors; and inhalation of viral particles by susceptible persons. Emissions are usefully clustered into three groups: small particles (diameter 0.1-5 µm), large particles (5-100 µm), and ballistic drops (>100 µm). Speaking generates particles and drops across the size spectrum. Small particles are removed from indoor air at room scale by ventilation, filtration, and deposition; large particles mainly deposit onto indoor surfaces. Proximate exposure enhancements are associated with large particles with contributions from ballistic drops. Masking and social distancing are effective in mitigating transmission from proximate exposures. At room scale, masking, ventilation, and filtration can contribute to limit exposures. Important information gaps prevent a quantitative reconciliation of the high overall global spread of COVID-19 with known transmission pathways. Available information supports several findings with moderate-to-high confidence: transmission occurs predominantly indoors; inhalation of airborne particles (up to 50 µm in diameter) contributes substantially to viral spread; transmission occurs in near proximity and at room scale; speaking is a major source of airborne SARS-CoV-2 virus; and emissions can occur without strong illness symptoms.
Collapse
Affiliation(s)
- William W Nazaroff
- Department of Civil and Environmental Engineering, University of California, Berkeley, California, USA
| |
Collapse
|
115
|
Tang JW, Tellier R, Li Y. Hypothesis: All respiratory viruses (including SARS-CoV-2) are aerosol-transmitted. INDOOR AIR 2022; 32:e12937. [PMID: 35104003 DOI: 10.1111/ina.12937] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2021] [Accepted: 09/22/2021] [Indexed: 06/14/2023]
Abstract
The potential role of aerosol transmission for seasonal respiratory viruses has been dramatically highlighted during the ongoing COVID-19 pandemic. It is now evident that short-range (conversational) and long-range aerosol transmission plays at least some part in how all these respiratory viruses are transmitted between people. This article highlights and discusses various studies that form the basis for this hypothesis.
Collapse
Affiliation(s)
- Julian W Tang
- Clinical Microbiology, Leicester Royal Infirmary, Leicester, UK
- Respiratory Sciences, University of Leicester, Leicester, UK
| | - Raymond Tellier
- Department of Medicine, McGill University, Montreal, Quebec, Canada
| | - Yuguo Li
- Department of Mechanical Engineering, The University of Hong Kong, Pokfulam, Hong Kong, China
| |
Collapse
|
116
|
Xu C, Liu W, Luo X, Huang X, Nielsen PV. Prediction and control of aerosol transmission of SARS-CoV-2 in ventilated context: from source to receptor. SUSTAINABLE CITIES AND SOCIETY 2022; 76:103416. [PMID: 34611508 PMCID: PMC8484231 DOI: 10.1016/j.scs.2021.103416] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Revised: 09/27/2021] [Accepted: 09/28/2021] [Indexed: 05/24/2023]
Abstract
Global spread of COVID-19 has seriously threatened human life and health. The aerosol transmission route of SARS-CoV-2 is observed often associated with infection clusters under poorly ventilated environment. In the context of COVID-19 pandemic, significant transformation and optimization of traditional ventilation systems are needed. This paper is aimed to offer better understanding and insights into effective ventilation design to maximize its ability in airborne risk control, for particularly the COVID-19. Comprehensive reviews of each phase of aerosol transmission of SARS-CoV-2 from source to receptor are conducted, so as to provide a theoretical basis for risk prediction and control. Infection risk models and their key parameters for risk assessment of SARS-CoV-2 are analyzed. Special focus is given on the efficacy of different ventilation strategies in mitigating airborne transmission. Ventilation interventions are found mainly impacting on the dispersion and inhalation phases of aerosol transmission. The airflow patterns become a key factor in controlling the aerosol diffusion and distribution. Novel and personalized ventilation design, effective integration with other environmental control techniques and resilient HVAC system design to adapt both common and epidemic conditions are still remaining challenging, which need to be solved with the aid of multidisciplinary research and intelligent technologies.
Collapse
Affiliation(s)
- Chunwen Xu
- College of Pipeline and Civil Engineering, China University of Petroleum, Qingdao 266580, China
| | - Wenbing Liu
- College of Pipeline and Civil Engineering, China University of Petroleum, Qingdao 266580, China
| | - Xilian Luo
- School of Human Settlements and Civil Engineering, Xi'an Jiaotong University, Xi'an 710049, China
| | - Xingyu Huang
- School of Human Settlements and Civil Engineering, Xi'an Jiaotong University, Xi'an 710049, China
| | - Peter V Nielsen
- Division of Sustainability, Energy and Indoor Environment, Aalborg University, Aalborg 9000, Denmark
| |
Collapse
|
117
|
Thornton GM, Fleck BA, Kroeker E, Dandnayak D, Fleck N, Zhong L, Hartling L. The impact of heating, ventilation, and air conditioning design features on the transmission of viruses, including the 2019 novel coronavirus: A systematic review of ventilation and coronavirus. PLOS GLOBAL PUBLIC HEALTH 2022; 2:e0000552. [PMID: 36962357 PMCID: PMC10021902 DOI: 10.1371/journal.pgph.0000552] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Accepted: 05/09/2022] [Indexed: 11/18/2022]
Abstract
Aerosol transmission has been a pathway for the spread of many viruses. Similarly, emerging evidence has determined aerosol transmission for Severe Acute Respiratory Syndrome coronavirus 2 (SARS-CoV-2) and the resulting COVID-19 pandemic to be significant. As such, data regarding the effect of Heating, Ventilation, and Air Conditioning (HVAC) features to control and mitigate virus transmission is essential. A systematic review was conducted to identify and comprehensively synthesize research examining the effectiveness of ventilation for mitigating transmission of coronaviruses. A comprehensive search was conducted in Ovid MEDLINE, Compendex, Web of Science Core to January 2021. Study selection, data extraction, and risk of bias assessments were performed by two authors. Evidence tables were developed and results were described narratively. Results from 32 relevant studies showed that: increased ventilation rate was associated with decreased transmission, transmission probability/risk, infection probability/risk, droplet persistence, virus concentration, and increased virus removal and virus particle removal efficiency; increased ventilation rate decreased risk at longer exposure times; some ventilation was better than no ventilation; airflow patterns affected transmission; ventilation feature (e.g., supply/exhaust, fans) placement influenced particle distribution. Few studies provided specific quantitative ventilation parameters suggesting a significant gap in current research. Adapting HVAC ventilation systems to mitigate virus transmission is not a one-solution-fits-all approach. Changing ventilation rate or using mixing ventilation is not always the only way to mitigate and control viruses. Practitioners need to consider occupancy, ventilation feature (supply/exhaust and fans) placement, and exposure time in conjunction with both ventilation rates and airflow patterns. Some recommendations based on quantitative data were made for specific scenarios (e.g., using air change rate of 9 h-1 for a hospital ward). Other recommendations included using or increasing ventilation, introducing fresh air, using maximum supply rates, avoiding poorly ventilated spaces, assessing fan placement and potentially increasing ventilation locations, and employing ventilation testing and air balancing checks. Trial registration: PROSPERO 2020 CRD42020193968.
Collapse
Affiliation(s)
- Gail M Thornton
- Faculty of Engineering, Department of Mechanical Engineering, University of Alberta, Edmonton, Canada
| | - Brian A Fleck
- Faculty of Engineering, Department of Mechanical Engineering, University of Alberta, Edmonton, Canada
| | - Emily Kroeker
- Faculty of Engineering, Department of Mechanical Engineering, University of Alberta, Edmonton, Canada
| | - Dhyey Dandnayak
- Faculty of Engineering, Department of Mechanical Engineering, University of Alberta, Edmonton, Canada
| | - Natalie Fleck
- Faculty of Engineering, Department of Mechanical Engineering, University of Alberta, Edmonton, Canada
| | - Lexuan Zhong
- Faculty of Engineering, Department of Mechanical Engineering, University of Alberta, Edmonton, Canada
| | - Lisa Hartling
- Faculty of Medicine & Dentistry, Department of Pediatrics, University of Alberta, Edmonton, Canada
| |
Collapse
|
118
|
Bueno de Mesquita PJ, Delp WW, Chan WR, Bahnfleth WP, Singer BC. Control of airborne infectious disease in buildings: Evidence and research priorities. INDOOR AIR 2022; 32:e12965. [PMID: 34816493 DOI: 10.1111/ina.12965] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/18/2021] [Revised: 10/07/2021] [Accepted: 11/11/2021] [Indexed: 06/13/2023]
Abstract
The evolution of SARS-CoV-2 virus has resulted in variants likely to be more readily transmitted through respiratory aerosols, underscoring the increased potential for indoor environmental controls to mitigate risk. Use of tight-fitting face masks to trap infectious aerosol in exhaled breath and reduce inhalation exposure to contaminated air is of critical importance for disease control. Administrative controls including the regulation of occupancy and interpersonal spacing are also important, while presenting social and economic challenges. Indoor engineering controls including ventilation, exhaust, air flow control, filtration, and disinfection by germicidal ultraviolet irradiation can reduce reliance on stringent occupancy restrictions. However, the effects of controls-individually and in combination-on reducing infectious aerosol transfer indoors remain to be clearly characterized to the extent needed to support widespread implementation by building operators. We review aerobiologic and epidemiologic evidence of indoor environmental controls against transmission and present a quantitative aerosol transfer scenario illustrating relative differences in exposure at close-interactive, room, and building scales. We identify an overarching need for investment to implement building controls and evaluate their effectiveness on infection in well-characterized and real-world settings, supported by specific, methodological advances. Improved understanding of engineering control effectiveness guides implementation at scale while considering occupant comfort, operational challenges, and energy costs.
Collapse
Affiliation(s)
| | - William W Delp
- Indoor Environment Group, Lawrence Berkeley National Laboratory, Berkeley, California, USA
| | - Wanyu R Chan
- Indoor Environment Group, Lawrence Berkeley National Laboratory, Berkeley, California, USA
| | - William P Bahnfleth
- Department of Architectural Engineering, Pennsylvania State University, State College, Pennsylvania, USA
| | - Brett C Singer
- Indoor Environment Group, Lawrence Berkeley National Laboratory, Berkeley, California, USA
| |
Collapse
|
119
|
Singer BC, Zhao H, Preble CV, Delp WW, Pantelic J, Sohn MD, Kirchstetter TW. Measured influence of overhead HVAC on exposure to airborne contaminants from simulated speaking in a meeting and a classroom. INDOOR AIR 2022; 32:e12917. [PMID: 34477251 DOI: 10.1111/ina.12917] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/19/2021] [Revised: 07/08/2021] [Accepted: 07/11/2021] [Indexed: 06/13/2023]
Abstract
Tracer gas experiments were conducted in a 158 m3 room with overhead supply diffusers to study dispersion of contaminants from simulated speaking in physically distanced meeting and classroom configurations. The room was contained within a 237 m3 cell with open plenum return to the HVAC system. Heated manikins at desks and a researcher operating the tracer release apparatus presented 8-9 thermal plumes. Experiments were conducted under conditions of no forced air and neutral, cooled, or heated air supplied at 980-1100 cmh, and with/out 20% outdoor air. CO2 was released at the head of one manikin in each experiment to simulate small (<5 µm diameter) respiratory aerosols. The metric of exposure relative to perfectly mixed (ERM) is introduced to quantify impacts, based on measurements at manikin heads and at three heights in the center and corners of the room. Chilled or neutral supply air provided good mixing with ERMs close to one. Thermal stratification during heating produced higher ERMs at most manikins: 25% were ≥2.5 and the highest were >5× perfectly mixed conditions. Operation of two within-zone air cleaners together moving ≥400 cmh vertically in the room provided enough mixing to mitigate elevated exposure variations.
Collapse
Affiliation(s)
- Brett C Singer
- Indoor Environment Group, Energy Analysis and Environmental Impacts Division, Building Technologies and Urban Systems Division, Energy Technologies Area, Lawrence Berkeley National Laboratory, Berkeley, California, USA
| | - Haoran Zhao
- Indoor Environment Group, Energy Analysis and Environmental Impacts Division, Building Technologies and Urban Systems Division, Energy Technologies Area, Lawrence Berkeley National Laboratory, Berkeley, California, USA
| | - Chelsea V Preble
- Indoor Environment Group, Energy Analysis and Environmental Impacts Division, Building Technologies and Urban Systems Division, Energy Technologies Area, Lawrence Berkeley National Laboratory, Berkeley, California, USA
- Department of Civil & Environmental Engineering, University of California, Berkeley, California, USA
| | - William W Delp
- Indoor Environment Group, Energy Analysis and Environmental Impacts Division, Building Technologies and Urban Systems Division, Energy Technologies Area, Lawrence Berkeley National Laboratory, Berkeley, California, USA
| | - Jovan Pantelic
- Indoor Environment Group, Energy Analysis and Environmental Impacts Division, Building Technologies and Urban Systems Division, Energy Technologies Area, Lawrence Berkeley National Laboratory, Berkeley, California, USA
- Center for the Built Environment, University of California, Berkeley, California, USA
| | - Michael D Sohn
- Indoor Environment Group, Energy Analysis and Environmental Impacts Division, Building Technologies and Urban Systems Division, Energy Technologies Area, Lawrence Berkeley National Laboratory, Berkeley, California, USA
| | - Thomas W Kirchstetter
- Indoor Environment Group, Energy Analysis and Environmental Impacts Division, Building Technologies and Urban Systems Division, Energy Technologies Area, Lawrence Berkeley National Laboratory, Berkeley, California, USA
- Department of Civil & Environmental Engineering, University of California, Berkeley, California, USA
| |
Collapse
|
120
|
Impact of Indoor-Outdoor Temperature Difference on Building Ventilation and Pollutant Dispersion within Urban Communities. ATMOSPHERE 2021. [DOI: 10.3390/atmos13010028] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Mechanical ventilation consumes a huge amount of global energy. Natural ventilation is a crucial solution for reducing energy consumption and enhancing the capacity of atmospheric self-purification. This paper evaluates the impacts of indoor-outdoor temperature differences on building ventilation and indoor-outdoor air pollutant dispersion in urban areas. The Computational Fluid Dynamics (CFD) method is employed to simulate the flow fields in the street canyon and indoor environment. Ventilation conditions of single-side ventilation mode and cross-ventilation mode are investigated. Air change rate, normalized concentration of traffic-related air pollutant (CO), intake fraction and exposure concentration are calculated to for ventilation efficiency investigation and exposure assessment. The results show that cross ventilation increases the air change rate for residential buildings under isothermal conditions. With the indoor-outdoor temperature difference, heating could increase the air change rate of the single-side ventilation mode but restrain the capability of the cross-ventilation mode in part of the floors. Heavier polluted areas appear in the upstream areas of single-side ventilation modes, and the pollutant can diffuse to middle-upper floors in cross-ventilation modes. Cross ventilation mitigates the environmental health stress for the indoor environment when indoor-outdoor temperature difference exits and the personal intake fraction is decreased by about 66% compared to the single-side ventilation. Moreover, the existence of indoor-outdoor temperature differences can clearly decrease the risk of indoor personal exposure under both two natural ventilation modes. The study numerically investigates the building ventilation and pollutant dispersion in the urban community with natural ventilation. The method and the results are helpful references for optimizing the building ventilation plan and improving indoor air quality.
Collapse
|
121
|
Effectiveness of barrier devices, high-volume evacuators, and extraoral suction devices on reducing dental aerosols for the dental operator: A pilot study. J Am Dent Assoc 2021; 153:309-318.e1. [PMID: 34952682 PMCID: PMC8885443 DOI: 10.1016/j.adaj.2021.08.011] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2020] [Revised: 07/30/2021] [Accepted: 08/29/2021] [Indexed: 11/23/2022]
Abstract
BACKGROUND The COVID-19 pandemic has increased the importance of minimizing exposure to aerosols generated during dental procedures. The authors' objective was to measure the aerosolized particles in the breathing zone of operators using several facial protection and filtration methods. METHODS Twenty-one dentists performed maxillary anterior incisor veneer preparations using a microscope and drape and loupes with or without a face shield. In each test condition, the following 3 levels of filtration were tested: no filtration, a high-volume evacuator [HVE], and an HVE with an extraoral suction device. Measurements were made using a mass monitor attached to the operator's chest with inlet within 10 inches of the operator's face. RESULTS The authors found that the microscope and drape provided the lowest levels of aerosolized particles compared with loupes with or without a face shield (P < .001). There was no detectable difference in the concentration of particles between operators wearing a face shield and wearing loupes alone (P = .47). The particles in each test condition were lowered when an HVE was used (P < .001) and further lowered with an extraoral suction device. CONCLUSIONS The findings of this study suggest that the use of a surgical microscope and bag barrier drape, HVE, and extraoral suction device result in the lowest concentration of aerosolized particles. The face shield did not appear to offer any protection from aerosolized particles. HVE and extraoral suction were effective in decreasing aerosols regardless of the type of facial protection used. PRACTICAL IMPLICATIONS Dentists can reduce exposure to aerosols with a drape, HVE, and extraoral suction.
Collapse
|
122
|
Coyle JP, Derk RC, Lindsley WG, Blachere FM, Boots T, Lemons AR, Martin SB, Mead KR, Fotta SA, Reynolds JS, McKinney WG, Sinsel EW, Beezhold DH, Noti JD. Efficacy of Ventilation, HEPA Air Cleaners, Universal Masking, and Physical Distancing for Reducing Exposure to Simulated Exhaled Aerosols in a Meeting Room. Viruses 2021; 13:2536. [PMID: 34960804 PMCID: PMC8707272 DOI: 10.3390/v13122536] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 12/07/2021] [Accepted: 12/14/2021] [Indexed: 12/12/2022] Open
Abstract
There is strong evidence associating the indoor environment with transmission of SARS-CoV-2, the virus that causes COVID-19. SARS-CoV-2 can spread by exposure to droplets and very fine aerosol particles from respiratory fluids that are released by infected persons. Layered mitigation strategies, including but not limited to maintaining physical distancing, adequate ventilation, universal masking, avoiding overcrowding, and vaccination, have shown to be effective in reducing the spread of SARS-CoV-2 within the indoor environment. Here, we examine the effect of mitigation strategies on reducing the risk of exposure to simulated respiratory aerosol particles within a classroom-style meeting room. To quantify exposure of uninfected individuals (Recipients), surrogate respiratory aerosol particles were generated by a breathing simulator with a headform (Source) that mimicked breath exhalations. Recipients, represented by three breathing simulators with manikin headforms, were placed in a meeting room and affixed with optical particle counters to measure 0.3-3 µm aerosol particles. Universal masking of all breathing simulators with a 3-ply cotton mask reduced aerosol exposure by 50% or more compared to scenarios with simulators unmasked. While evaluating the effect of Source placement, Recipients had the highest exposure at 0.9 m in a face-to-face orientation. Ventilation reduced exposure by approximately 5% per unit increase in air change per hour (ACH), irrespective of whether increases in ACH were by the HVAC system or portable HEPA air cleaners. The results demonstrate that mitigation strategies, such as universal masking and increasing ventilation, reduce personal exposure to respiratory aerosols within a meeting room. While universal masking remains a key component of a layered mitigation strategy of exposure reduction, increasing ventilation via system HVAC or portable HEPA air cleaners further reduces exposure.
Collapse
Affiliation(s)
- Jayme P. Coyle
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV 26505, USA; (J.P.C.); (R.C.D.); (F.M.B.); (T.B.); (A.R.L.); (J.S.R.); (W.G.M.); (E.W.S.); (D.H.B.); (J.D.N.)
| | - Raymond C. Derk
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV 26505, USA; (J.P.C.); (R.C.D.); (F.M.B.); (T.B.); (A.R.L.); (J.S.R.); (W.G.M.); (E.W.S.); (D.H.B.); (J.D.N.)
| | - William G. Lindsley
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV 26505, USA; (J.P.C.); (R.C.D.); (F.M.B.); (T.B.); (A.R.L.); (J.S.R.); (W.G.M.); (E.W.S.); (D.H.B.); (J.D.N.)
| | - Francoise M. Blachere
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV 26505, USA; (J.P.C.); (R.C.D.); (F.M.B.); (T.B.); (A.R.L.); (J.S.R.); (W.G.M.); (E.W.S.); (D.H.B.); (J.D.N.)
| | - Theresa Boots
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV 26505, USA; (J.P.C.); (R.C.D.); (F.M.B.); (T.B.); (A.R.L.); (J.S.R.); (W.G.M.); (E.W.S.); (D.H.B.); (J.D.N.)
| | - Angela R. Lemons
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV 26505, USA; (J.P.C.); (R.C.D.); (F.M.B.); (T.B.); (A.R.L.); (J.S.R.); (W.G.M.); (E.W.S.); (D.H.B.); (J.D.N.)
| | - Stephen B. Martin
- Respiratory Health Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV 26505, USA;
| | - Kenneth R. Mead
- Division of Field Studies and Engineering, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Cincinnati, OH 45226, USA;
| | - Steven A. Fotta
- Facilities Management Office, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV 26505, USA;
| | - Jeffrey S. Reynolds
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV 26505, USA; (J.P.C.); (R.C.D.); (F.M.B.); (T.B.); (A.R.L.); (J.S.R.); (W.G.M.); (E.W.S.); (D.H.B.); (J.D.N.)
| | - Walter G. McKinney
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV 26505, USA; (J.P.C.); (R.C.D.); (F.M.B.); (T.B.); (A.R.L.); (J.S.R.); (W.G.M.); (E.W.S.); (D.H.B.); (J.D.N.)
| | - Erik W. Sinsel
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV 26505, USA; (J.P.C.); (R.C.D.); (F.M.B.); (T.B.); (A.R.L.); (J.S.R.); (W.G.M.); (E.W.S.); (D.H.B.); (J.D.N.)
| | - Donald H. Beezhold
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV 26505, USA; (J.P.C.); (R.C.D.); (F.M.B.); (T.B.); (A.R.L.); (J.S.R.); (W.G.M.); (E.W.S.); (D.H.B.); (J.D.N.)
| | - John D. Noti
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV 26505, USA; (J.P.C.); (R.C.D.); (F.M.B.); (T.B.); (A.R.L.); (J.S.R.); (W.G.M.); (E.W.S.); (D.H.B.); (J.D.N.)
| |
Collapse
|
123
|
Srivastava S, Zhao X, Manay A, Chen Q. Effective ventilation and air disinfection system for reducing coronavirus disease 2019 (COVID-19) infection risk in office buildings. SUSTAINABLE CITIES AND SOCIETY 2021; 75:103408. [PMID: 34603942 PMCID: PMC8479514 DOI: 10.1016/j.scs.2021.103408] [Citation(s) in RCA: 41] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2021] [Revised: 09/24/2021] [Accepted: 09/25/2021] [Indexed: 05/09/2023]
Abstract
During the COVID-19 pandemic, an increasing amount of evidence has suggested that the virus can be transmitted through the air inside buildings. The ventilation system used to create the indoor environment would facilitate the transmission of the airborne infectious diseases. However, the existing ventilation systems in most buildings cannot supply sufficient clean outdoor air for diluting the virus concentration. To reduce the airborne infection risk and minimize energy consumption, especially in existing buildings with well-mixed ventilation systems, this investigation used an ultraviolet-C (UV-C) air disinfection device (Rheem's third generation products, RM3) with 99.9% disinfection efficiency to clean air carrying the COVID-19 virus (severe acute respiratory syndrome coronavirus 2, SARS-CoV-2) which could help promote environmental sustainability and create healthy cities. This investigation assessed the impact of the RM3 UV-C units on the infection risk, the number of RM3 UV-C units required, and the strategy for decreasing the infection risk, with the use of computational-fluid-dynamics (CFD) numerical simulations. An actual office building with a combination of individual offices and workstations was selected as an example for the research. According to the numerical results, the best strategy would be to use a combination of 100% outside air and UV-C in heating, ventilation and air-conditioning (HVAC) ducts with air disinfected by the RM3 UV-C units. The infection risk in the office building could thus be reduced to a negligible level. These findings could provide theoretical basis and engineering application basis for COVID-19 epidemic prevention and control.
Collapse
Affiliation(s)
- Shubham Srivastava
- Water Heater Division, Rheem Manufacturing Company Inc, Atlanta, GA 30328, USA
| | - Xingwang Zhao
- School of Energy and Environment, Southeast University, Nanjing 210096, China
| | - Ati Manay
- Water Heater Division, Rheem Manufacturing Company Inc, Atlanta, GA 30328, USA
| | - Qingyan Chen
- School of Mechanical Engineering, Purdue University, West Lafayette, IN 47907, USA
| |
Collapse
|
124
|
The effect of door opening on air-mixing in a positively pressurized room: Implications for operating room air management during the COVID outbreak. JOURNAL OF BUILDING ENGINEERING 2021; 44:102900. [PMCID: PMC8214326 DOI: 10.1016/j.jobe.2021.102900] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/07/2020] [Revised: 05/19/2021] [Accepted: 06/15/2021] [Indexed: 05/31/2023]
Abstract
The effect of the built environment on the predominant indoor airflow patterns is significant. To protect the healthcare workers at the front line from the outbreak of COVID − 19, it is necessary to understand the transmission dynamics of the virus, which has been shown to depend on indoor airflow patterns. In hospital operating rooms (ORs), design requirements pose a unique challenge as the positive pressure in the OR can facilitate virus spread into adjacent spaces, shall a COVID-positive patient require a surgical procedure. Moreover, the turbulent vortexes from door motions could independently increase the probability of virus escape from the OR to the adjacent corridors. Therefore, to obtain critical knowledge about the alteration of flow fields due to door movement in a positively pressurized room and quantify the air mixing across the door, a series of experiments were conducted in a controlled chamber. The results demonstrate significant impacts of the door opening on the airflow patterns. Increased alterations near the door and vortexes penetrating far into the chamber with multiple doors openings warrant further study of the indoor airflow dynamic under door motion. This experimental study proposes an algorithm to quantify the air exchange due to a standard door opening and quantifies this exfiltration of contaminated air up to 2 air changes per hour, that is 10% of the chamber supply airflow rate. The algorithm to quantify the dissipated air quantity and the analyses of interaction between initial conditions and door openings contribute to the originality of this paper.
Collapse
|
125
|
Interaction between Thermal Comfort, Indoor Air Quality and Ventilation Energy Consumption of Educational Buildings: A Comprehensive Review. BUILDINGS 2021. [DOI: 10.3390/buildings11120591] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Thermal comfort and indoor air quality (IAQ) of educational buildings can affect students’ academic performance and well-being and are closely related to ventilation energy consumption. Demands of the indoor environmental quality within the classroom generally vary with the education levels and result in ventilation energy consumption accounting for a considerable proportion of the total energy use in bulk educational buildings. Its huge energy-saving potential is attracting worldwide attention from scholars and governments. Therefore, appropriate operation strategies of ventilation systems should be adopted to effectively reduce energy consumption without sacrificing thermal comfort and IAQ. However, the absence of relevant standards and guidelines for designing a quality classroom environment considering the special features of educational buildings remains an important research question. This study conducts a comprehensive review to determine research gaps and identify future directions for the interaction between thermal comfort, IAQ and ventilation energy consumption for educational buildings. The review results show that: (1) The thermal comfort prediction model should consider the influences of genders, ages and socioeconomic backgrounds; (2) The mixed-mode ventilation coupling the natural and mechanical approaches is preferred given its advantage of lower energy consumption and improved thermal comfort, but its control strategies need further exploration; (3) Optimizing passive design parameters of buildings (e.g., window to wall ratios, window orientations and sun shading installations) can significantly reduce the ventilation demands while maintaining indoor thermal comfort; (4) More studies are required for investigating thermal comfort in educational buildings during the heating period; and (5) IAQ of university buildings clearly requires further studies, especially on bacterial and fungal aerosol pollutants, for a more comprehensive assessment of the built environment.
Collapse
|
126
|
Lebreil AL, Greux V, Glenet M, Huguenin A, N'Guyen Y, Berri F, Bajolet O, Mourvillier B, Andreoletti L. Surfaces and Air contamination by SARS-CoV-2 using High-flow Nasal Oxygenation or Assisted Mechanical Ventilation System in ICU rooms of COVID-19 Patients. J Infect Dis 2021; 225:385-391. [PMID: 34788831 DOI: 10.1093/infdis/jiab564] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2021] [Accepted: 11/08/2021] [Indexed: 11/14/2022] Open
Abstract
BACKGROUND Understanding patterns of environmental contamination by SARS-CoV-2 is essential for infection prevention policies. METHODS We screened surfaces and air samples from single bed ICU rooms of COVID-19 adult patients for SARS-CoV-2 RNA and viable viruses. RESULTS AND DISCUSSION We evidenced viral RNA environmental contamination in 76% of 100 surfaces samples and in 30% of 40 air samples without any viable virus detection by cell culture assays. No significant differences of viral RNA levels on surfaces and in ambient air were observed between rooms of patients with assisted mechanical ventilation and those of patients with high-flow nasal cannula system. Using an original experimental SARS-CoV-2 infection model of surfaces, we assessed that infectious viruses might have been present on benches within 15 hours before the time of sampling in patient rooms. CONCLUSIONS We observed that SARS-CoV-2 environmental contamination around COVID-19 patients hospitalized in single ICU rooms was extensive and that a high-flow nasal cannula system did not generate more viral aerosolization than a mechanical ventilation system in COVID-19 patients. Despite an absence of SARS-CoV-2 viable particles in study samples, our experimental model confirmed the need to apply strict environmental disinfection procedures and classical standard and droplet precautions in ICU wards.
Collapse
Affiliation(s)
| | - Vincent Greux
- CHU Reims, Hôpital Robert Debré, Intensive Care Unit (UMIRP), Reims, France
| | - Marie Glenet
- Université de Reims Champagne Ardenne, Cardiovir EA-4684, Reims, France
| | - Antoine Huguenin
- CHU Reims, Hôpital Robert Debré, Parasitology Department, Reims, France.,Université de Reims Champagne Ardenne, ESCAPE EA7510, 51097 Reims, France
| | - Yohan N'Guyen
- Université de Reims Champagne Ardenne, Cardiovir EA-4684, Reims, France.,CHU Reims, Hôpital Robert Debré, Infectious diseases and internal medicine Department, Reims, France
| | - Fatma Berri
- Université de Reims Champagne Ardenne, Cardiovir EA-4684, Reims, France
| | - Odile Bajolet
- CHU Reims, Hôpital Robert Debré, Hygiene Department, Reims, France
| | - Bruno Mourvillier
- Université de Reims Champagne Ardenne, Cardiovir EA-4684, Reims, France.,CHU Reims, Hôpital Robert Debré, Intensive Care Unit (UMIRP), Reims, France
| | - Laurent Andreoletti
- Université de Reims Champagne Ardenne, Cardiovir EA-4684, Reims, France.,CHU Reims, Hôpital Robert Debré, Virology Department, Reims, France
| |
Collapse
|
127
|
Gregorio PHP, Mariani AW, Brito JMLT, Santos BJM, Pêgo-Fernandes PM. Indoor Air Quality and Environmental Sampling as Support Tools to Detect SARS-CoV-2 in the Healthcare Setting. J Occup Environ Med 2021; 63:956-962. [PMID: 34739441 PMCID: PMC8562924 DOI: 10.1097/jom.0000000000002284] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
OBJECTIVES To evaluate severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spread inside the healthcare setting using environmental sampling and indoor air quality (IAQ) parameters. METHODS Ward/ICU rooms had IAQ parameters monitored in real-time, including volatile organic compounds and particulate matter. Surface and three air samples with different exposure times were collected in each room and tested for SARS-CoV-2 using quantitative Rt-PCR. Environmental sampling and IAQ data were compared to provide information about viral spread. RESULTS SARS-CoV-2 RNA was detected in 6/10 rooms and 9/30 air samples, which is proportionally higher than previous studies. Sampling time confirmed to be crucial to viral detection. No correlations between IAQ parameters could be associated with positive/negative samples even when aerosol-generating procedures were performed. CONCLUSION Environmental sampling of SARS-CoV-2 RNA may be used as an indicator of occupational safety. IAQ is also a potential tool but requires further research.
Collapse
Affiliation(s)
- Paulo Henrique Peitl Gregorio
- Thoracic Surgery Department, Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo - São Paulo, São Paulo, Brazil (Drs Gregorio, Mariani, Brito, Santos, and Fernandes)
| | | | | | | | | |
Collapse
|
128
|
Locke L, Dada O, Shedd JS. Aerosol Transmission of Infectious Disease and the Efficacy of Personal Protective Equipment (PPE): A Systematic Review. J Occup Environ Med 2021; 63:e783-e791. [PMID: 34419986 PMCID: PMC8562920 DOI: 10.1097/jom.0000000000002366] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
OBJECTIVE Health care professionals and governmental agencies are in consensus regarding contact and droplet transmission of infectious diseases. However, personal protective equipment (PPE) efficacy is not considered for aerosol or airborne transmission of infectious diseases. This review discusses the inhalation of virus-laden aerosols as a viable mechanism of transmission of various respiratory infectious diseases and PPE efficacy. METHODS The Preferred Reporting Items for Systematic reviews, and Meta-Analysis (PRISMA) guidelines was used. RESULTS The transmission of infectious disease is of concern for all respirable diseases discussed (SARS-CoV-1, SARS-CoV-2, MERS, influenza, and tuberculosis), and the effectiveness of facemasks is dependent on the efficiency of the filter, fit, and proper use. CONCLUSION PPE should be the last resort in preventing the spread of infectious disease and should only be used for protection and not to control the transmission.
Collapse
Affiliation(s)
- Laramie Locke
- Department of Occupational Safety and Health, Murray State University, Kentucky (Mr Locke, Dr Dada); Eastman Chemical Company, Tennessee (Mr Locke); and Department of Environmental Health Sciences, University of Alabama at Birmingham, Birmingham, Alabama (Mr Shedd)
| | | | | |
Collapse
|
129
|
A novel U-shaped acoustic-manipulated design to enhance the performance of low-efficiency filters for sub-micron particles. POWDER TECHNOL 2021. [DOI: 10.1016/j.powtec.2021.07.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
130
|
Elsaid AM, Mohamed HA, Abdelaziz GB, Ahmed MS. A critical review of heating, ventilation, and air conditioning (HVAC) systems within the context of a global SARS-CoV-2 epidemic. PROCESS SAFETY AND ENVIRONMENTAL PROTECTION : TRANSACTIONS OF THE INSTITUTION OF CHEMICAL ENGINEERS, PART B 2021; 155:230-261. [PMID: 34566275 PMCID: PMC8450051 DOI: 10.1016/j.psep.2021.09.021] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/27/2020] [Revised: 09/12/2021] [Accepted: 09/13/2021] [Indexed: 05/06/2023]
Abstract
The Coronavirus disease (COVID-19) has spread over the world, resulting in more than 225 million patients, and 4.7 million deaths in September 2021. It also caused panic and terror, halted numerous activities, and resulted in the world economy deteriorates. It altered human behavior and compelled people to alter their lifestyles to avoid infection. Air conditioning systems are one of the most important sectors that must be considered because of the pandemic SARS-CoV-2 all over the world. Air is used as a heat transfer medium in heating, ventilation, and air conditioning (HVAC) systems. The air contains a variety of pollutants, viruses, and bacteria, all of which have an impact on and destroy human life. Significantly in summer, people spend more time in air conditioners which results in lower levels of vitamin D and melatonin which may affect the functioning of their immune system and are susceptible to receiving SARS-CoV-2 from other individuals. As an important component of air conditioning and ventilation systems, the air filter plays a significant role. As a result, researchers must work harder to improve its design to prevent the ultra-small particles loaded with COVID-19. This paper contributes to the design of existing HVAC systems in terms of their suitability and impact on the spread of the hybrid SARS-CoV-2 epidemic, as well as efforts to obtain a highly efficient air filter to remove super-sized particles for protection against epidemic infection. In addition, important guideline recommendations have been extracted to limit the spread of the SARS-CoV-2 throughout the world and to get the highest quality indoor air in air-conditioned places.
Collapse
Affiliation(s)
- Ashraf Mimi Elsaid
- Department of Refrigeration and Air Conditioning Technology, Faculty of Technology and Education, Helwan University, Cairo 11282, Egypt
| | - Hany A Mohamed
- Department of Mechanical Engineering, Faculty of Engineering, Assiut University, Asyut 71516, Egypt
- Mechanical Engineering Department, Higher Technological Institute, 10th Ramadan, Ramadan City 44634, Egypt
| | - Gamal B Abdelaziz
- Mechanical Department, Faculty of Technology and Education, Suez University, Suez, Egypt
| | - M Salem Ahmed
- Mechanical Department, Faculty of Technology and Education, Sohag University, Sohag, Egypt
| |
Collapse
|
131
|
Sanglier-Contreras G, López-Fernández EJ, González-Lezcano RA. Poor Ventilation Habits in Nursing Homes Have Favoured a High Number of COVID-19 Infections. SUSTAINABILITY 2021; 13:11898. [DOI: 10.3390/su132111898] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Residents of nursing homes have been significantly affected by COVID-19 in Spain. The factors that have contributed to the vulnerability of this population are very diverse. In this study, physical agents, chemical pollutants, population density and different capacities of residences were analysed to understand their influence on the number of elderly people who have died in geriatric centres in different autonomous communities (AACCs) of Spain. A statistical analysis was carried out on the variables observed. The results show that many residences with a larger number of deaths were private, with some exceptions. Physical agents and pollutants were found to be determining factors, especially for the communities of Extremadura and Castilla–La Mancha, although the large number of factors involved makes this study complicated. The compromise between air quality and energy efficiency is of great importance, especially when human health is at stake.
Collapse
Affiliation(s)
- Gastón Sanglier-Contreras
- Architecture and Design Department, Escuela Politécnica Superior, Campus Montepríncipe, Universidad San Pablo CEU, CEU Universities, Boadilla del Monte, 28668 Madrid, Spain
| | - Eduardo J. López-Fernández
- Architecture and Design Department, Escuela Politécnica Superior, Campus Montepríncipe, Universidad San Pablo CEU, CEU Universities, Boadilla del Monte, 28668 Madrid, Spain
| | - Roberto Alonso González-Lezcano
- Architecture and Design Department, Escuela Politécnica Superior, Campus Montepríncipe, Universidad San Pablo CEU, CEU Universities, Boadilla del Monte, 28668 Madrid, Spain
| |
Collapse
|
132
|
Dengiz E, Özcan Ç, Güven Yİ, Uçar S, Ener BK, Sözen S, Yağcı B, Güzel İA, Yiğit B, Andaç A, Güneş B, Bor E, Karabudak U, Kaya A. Ozone gas applied through nebulization as adjuvant treatment for lung respiratory diseases due to COVID-19 infections: a prospective randomized trial. Med Gas Res 2021; 12:55-59. [PMID: 34677153 PMCID: PMC8562398 DOI: 10.4103/2045-9912.326001] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023] Open
Abstract
The objective of this study was to provide lung disinfection by nebulizing ozone gas with distilled water and olive oil for patients who have clinical symptoms due to coronavirus disease 2019 (COVID-19). The study attempted to reduce the viral load of COVID-19 in the lungs of patients, to provide a faster response to medical treatment. Between August 2020 and September 2020, 30 patients who met the study criteria were prospectively evaluated. There were 2 groups with 15 patients in each group: patients in control group were not treated with ozone and only received standard COVID-19 treatment; patients in ozone group received lung disinfection technique with ozone and standard COVID-19 treatment. A statistically significant difference was found in the length of stay in hospital, change in C-reactive protein, polymerase chain reaction results after 5 days, and computed tomography scores between two groups. There was no statistically significant difference in D-dimer, urea, lactate dehydrogenase, lymphocyte, leukocyte, and platelet between two groups. According to the data, we think that the lung disinfection technique applied with ozone inhalation reduces the rate of pneumonia in COVID-19 patients and makes the patients respond faster to the treatment and become negative according to the polymerase chain reaction tests. The study was approved by the Ethical Committee of the İstanbul Medipol University Clinical Trials (approval No. 0011) on July 2, 2020.
Collapse
Affiliation(s)
- Erhan Dengiz
- Edis Pharma Pharmaceutical Industry, Istanbul, Turkey
| | - Çağrı Özcan
- Health Science Univercity, Umraniye Training and Research Hospital, Istanbul, Turkey
| | | | - Selcen Uçar
- Dr. Feriha Öz Emergency Hospital, İstanbul, Turkey
| | - Behçet Kemal Ener
- Health Science Univercity, Umraniye Training and Research Hospital, Istanbul, Turkey
| | | | - Buket Yağcı
- Health Science Univercity, Haydarpasa Training and Research Hospital, İstanbul, Turkey
| | | | - Betül Yiğit
- Dr. Feriha Öz Emergency Hospital, İstanbul, Turkey
| | | | | | - Emire Bor
- Edis Pharma Pharmaceutical Industry, Istanbul, Turkey
| | | | - Ali Kaya
- Edis Pharma Pharmaceutical Industry, Istanbul, Turkey
| |
Collapse
|
133
|
Low-Invasive CO2-Based Visual Alerting Systems to Manage Natural Ventilation and Improve IAQ in Historic School Buildings. HERITAGE 2021. [DOI: 10.3390/heritage4040191] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Children spend a large part of their growing years in schools, and as they are more sensitive to some pollutants than adults, it is essential to monitor and maximize the indoor air quality (IAQ) in classrooms. Many schools are located in historic and heritage buildings, and improving the IAQ, preserving the architectural features, poses a great challenge. The aim of the study is to evaluate the effectiveness of a low-invasiveness, low-cost, smart CO2-based visual alerting systems to manage natural ventilation and improve IAQ in historic school buildings. Indoor and outdoor parameters were monitored for three weeks in four schools with different levels of education (two classrooms per school; device installed in one only). Based on indoor CO2 concentration, air temperature and relative humidity, the device suggests when windows should be opened to ventilate. The comparison between the two classrooms show that the effectiveness of the device is highly dependent on the occupants: (i) reduction in the average CO2 concentrations of up to 42% in classrooms with frontal lesson and full occupancy, (ii) the device is not the most ideal solution for kindergarten due to the young age of the pupils, and (iii) it is more used during mild outdoor temperatures.
Collapse
|
134
|
Termansen MB, Christiansen AV, Frische S. SARS-CoV-2 prevalence and transmission in swimming activities: Results from a retrospective cohort study. Scand J Med Sci Sports 2021; 32:242-254. [PMID: 34606662 PMCID: PMC8662273 DOI: 10.1111/sms.14071] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2021] [Revised: 09/28/2021] [Accepted: 10/01/2021] [Indexed: 12/20/2022]
Abstract
There is an urgent need for research on the epidemiology of severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) causing coronavirus disease 2019 (COVID‐19), as the transmissibility differs between settings and populations. Here we report on a questionnaire‐based retrospective cohort study of the prevalence and transmission of SARS‐CoV‐2 among participants in swimming activities in Denmark in the last 5 months of 2020 during the COVID‐19 pandemic. Eight of 162 swimming activities with a SARS‐CoV‐2 positive participant led to transmission to 23 other participants. Overall, the percentage of episodes leading to transmission was 4.9% (competitive swimming 8.9%; recreational swimming 1.3%). Overall, the incidence rate of transmission was 19.5 participants per 100 000 pool activity hours (corresponding values: 43.5 and 4.7 for competitive and recreational swimming, respectively). Compliance with precautionary restrictions was highest regarding hand hygiene (98.1%) and lowest in distancing personal sports bags (69.9%). As a result of low statistical power, the study showed no significant effect of restrictions. Insight into the risk of transmission of SARS‐CoV‐2 during indoor swimming is needed to estimate the efficiency of restrictive measures on this and other sports and leisure activities. Only when we know how the virus spreads through various settings, optimal strategies to handle the COVID‐19 pandemic can be developed.
Collapse
|
135
|
Saw LH, Leo BF, Nor NSM, Yip CW, Ibrahim N, Hamid HHA, Latif MT, Lin CY, Nadzir MSM. Modeling aerosol transmission of SARS-CoV-2 from human-exhaled particles in a hospital ward. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2021; 28:53478-53492. [PMID: 34036501 PMCID: PMC8148403 DOI: 10.1007/s11356-021-14519-9] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/07/2021] [Accepted: 05/17/2021] [Indexed: 06/04/2023]
Abstract
The COVID-19 pandemic has plunged the world into uncharted territory, leaving people feeling helpless in the face of an invisible threat of unknown duration that could adversely impact the national economic growths. According to the World Health Organization (WHO), the SARS-CoV-2 spreads primarily through droplets of saliva or discharge from the mouth or nose when an infected person coughs or sneezes. However, the transmission of the SARS-CoV-2 through aerosols remains unclear. In this study, computational fluid dynamic (CFD) is used to complement the investigation of the SARS-CoV-2 transmission through aerosol. The Lagrangian particle tracking method was used to analyze the dispersion of the exhaled particles from a SARS-CoV-2-positive patient under different exhale activities and different flow rates of chilled (cooling) air supply. Air sampling of the SARS-CoV-2 patient ward was conducted for 48-h measurement intervals to collect the indoor air sample for particulate with diameter less than 2.5 μm. Then, the reverse transcription quantitative real-time polymerase chain reaction (RT-qPCR) was conducted to analyze the collected air sample. The simulation demonstrated that the aerosol transmission of the SARS-CoV-2 virus in an enclosed room (such as a hospital ward) is highly possible.
Collapse
Affiliation(s)
- Lip Huat Saw
- Lee Kong Chian, Faculty of Engineering and Science, Universiti Tunku Abdul Rahman, 43000, Kajang, Selangor, Malaysia
| | - Bey Fen Leo
- Faculty of Medicine, Universiti Malaya, 50603, Kuala Lumpur, Malaysia.
| | - Norefrina Shafinaz Md Nor
- Department of Biological Sciences and Biotechnology, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43600, Bangi, Selangor, Malaysia
| | - Chee Wai Yip
- Department of Biological Sciences and Biotechnology, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43600, Bangi, Selangor, Malaysia
| | - Nazlina Ibrahim
- Department of Biological Sciences and Biotechnology, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43600, Bangi, Selangor, Malaysia
| | - Haris Hafizal Abd Hamid
- Department of Earth Sciences and Environment, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43600, Bangi, Selangor, Malaysia
| | - Mohd Talib Latif
- Department of Earth Sciences and Environment, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43600, Bangi, Selangor, Malaysia
| | - Chin Yik Lin
- Department of Geology, Faculty of Science, Universiti Malaya, 50603, Kuala Lumpur, Malaysia
| | - Mohd Shahrul Mohd Nadzir
- Department of Earth Sciences and Environment, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43600, Bangi, Selangor, Malaysia.
| |
Collapse
|
136
|
Park S, Choi Y, Song D, Kim EK. Natural ventilation strategy and related issues to prevent coronavirus disease 2019 (COVID-19) airborne transmission in a school building. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 789:147764. [PMID: 34051507 PMCID: PMC8123370 DOI: 10.1016/j.scitotenv.2021.147764] [Citation(s) in RCA: 55] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Revised: 05/02/2021] [Accepted: 05/10/2021] [Indexed: 05/18/2023]
Abstract
The World Health Organization (WHO) announced that severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) may spread through aerosols, so-called airborne transmission, especially in a poorly ventilated indoor environment. Ventilation protects the occupants against airborne transmission. Various studies have been performed on the importance of sufficient ventilation for diluting the concentration of virus and lowering any subsequent dose inhaled by the occupants. However, the ventilation situation can be problematic in public buildings and other shared spaces, such as shops, offices, schools, and restaurants. If ventilation is provided by opening windows, the outdoor airflow rate depends strongly on the specific local conditions (opening sizes, relative positions, climatic and weather conditions). This study uses field measurements to analyze the natural ventilation performance in a school building according to the window opening rates, positions, and weather conditions. The ventilation rates were calculated by the tracer gas decay method, and the infection risk was assessed using the Wells-Riley equation. Under cross-ventilation conditions, the average ventilation rates were measured at 6.51 h-1 for 15% window opening, and 11.20 h-1 for 30% window opening. For single-sided ventilation, the ventilation rates were reduced to about 30% of the values from the cross-ventilation cases. The infection probability is less than 1% in all cases when a mask is worn and more than 15% of the windows are open with cross-ventilation. With single-sided ventilation, if the exposure time is less than 1 h, the infection probability can be kept less than 1% with a mask. However, the infection probability exceeds 1% in all cases where exposure time is greater than 2 h, regardless of whether or not a mask is worn. Also, when the air conditioner was operated with a window opening ratio of 15%, power consumption increased by 10.2%.
Collapse
Affiliation(s)
- Sowoo Park
- School of Civil, Architectural and Environmental System Eng., Graduate School of Sungkyunkwan University, 2066 Seobu-ro, Suwon 16419, South Korea
| | - Younhee Choi
- Faculty of Human-Environment Studies, Kyushu University, 744 Motooka Nishi-ku, Fukuoka 819-0395, Japan
| | - Doosam Song
- School of Civil, Architectural Eng., and Landscape Architecture, Sungkyunkwan University, 2066 Seobu-ro, Suwon 16419, South Korea.
| | - Eun Kyung Kim
- Department of Allergy, Pulmonary and Critical Care Medicine, CHA Bundang Medical Center, CHA University, Seongnam, South Korea.
| |
Collapse
|
137
|
Pourfattah F, Wang LP, Deng W, Ma YF, Hu L, Yang B. Challenges in simulating and modeling the airborne virus transmission: A state-of-the-art review. PHYSICS OF FLUIDS (WOODBURY, N.Y. : 1994) 2021; 33:101302. [PMID: 34803360 PMCID: PMC8597718 DOI: 10.1063/5.0061469] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/26/2021] [Accepted: 10/04/2021] [Indexed: 06/09/2023]
Abstract
Recently, the COVID-19 virus pandemic has led to many studies on the airborne transmission of expiratory droplets. While limited experiments and on-site measurements offer qualitative indication of potential virus spread rates and the level of transmission risk, the quantitative understanding and mechanistic insights also indispensably come from careful theoretical modeling and numerical simulation efforts around which a surge of research papers has emerged. However, due to the highly interdisciplinary nature of the topic, numerical simulations of the airborne spread of expiratory droplets face serious challenges. It is essential to examine the assumptions and simplifications made in the existing modeling and simulations, which will be reviewed carefully here to better advance the fidelity of numerical results when compared to the reality. So far, existing review papers have focused on discussing the simulation results without questioning or comparing the model assumptions. This review paper focuses instead on the details of the model simplifications used in the numerical methods and how to properly incorporate important processes associated with respiratory droplet transmission. Specifically, the critical issues reviewed here include modeling of the respiratory droplet evaporation, droplet size distribution, and time-dependent velocity profile of air exhaled from coughing and sneezing. According to the literature review, another problem in numerical simulations is that the virus decay rate and suspended viable viral dose are often not incorporated; therefore here, empirical relationships for the bioactivity of coronavirus are presented. It is hoped that this paper can assist researchers to significantly improve their model fidelity when simulating respiratory droplet transmission.
Collapse
Affiliation(s)
- Farzad Pourfattah
- Guangdong Provincial Key Laboratory of Turbulence Research and Applications, Center for Complex Flows and Soft Matter Research and Department of Mechanics and Aerospace Engineering, Southern University of Science and Technology, Shenzhen 518055, People's Republic of China
| | | | - Weiwei Deng
- Guangdong Provincial Key Laboratory of Turbulence Research and Applications, Center for Complex Flows and Soft Matter Research and Department of Mechanics and Aerospace Engineering, Southern University of Science and Technology, Shenzhen 518055, People's Republic of China
| | - Yong-Feng Ma
- Guangdong Provincial Key Laboratory of Turbulence Research and Applications, Center for Complex Flows and Soft Matter Research and Department of Mechanics and Aerospace Engineering, Southern University of Science and Technology, Shenzhen 518055, People's Republic of China
| | - Liangquan Hu
- Guangdong Provincial Key Laboratory of Turbulence Research and Applications, Center for Complex Flows and Soft Matter Research and Department of Mechanics and Aerospace Engineering, Southern University of Science and Technology, Shenzhen 518055, People's Republic of China
| | - Bo Yang
- Guangdong Provincial Key Laboratory of Turbulence Research and Applications, Center for Complex Flows and Soft Matter Research and Department of Mechanics and Aerospace Engineering, Southern University of Science and Technology, Shenzhen 518055, People's Republic of China
| |
Collapse
|
138
|
Deng X, Gong G, He X, Shi X, Mo L. Control of exhaled SARS-CoV-2-laden aerosols in the interpersonal breathing microenvironment in a ventilated room with limited space air stability. J Environ Sci (China) 2021; 108:175-187. [PMID: 34465431 PMCID: PMC7835081 DOI: 10.1016/j.jes.2021.01.025] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2020] [Revised: 01/20/2021] [Accepted: 01/21/2021] [Indexed: 05/31/2023]
Abstract
The Coronavirus Disease 2019 (COVID-19) highlights the importance of understanding and controlling the spread of the coronavirus between persons. We experimentally and numerically investigated an advanced engineering and environmental method on controlling the transmission of airborne SARS-CoV-2-laden aerosols in the breathing microenvironment between two persons during interactive breathing process by combining the limited space air stability and a ventilation method. Experiments were carried out in a full-scale ventilated room with different limited space air stability conditions, i.e., stable condition, neutral condition and unstable condition. Two real humans were involved to conducted normal breathing process in the room and the exhaled carbon dioxide was used as the surrogate of infectious airborne SARS-CoV-2-laden aerosols from respiratory activities. A correspondent numerical model was established to visualize the temperature field and contaminated field in the test room. Results show that the performance of a ventilation system on removing infectious airborne SARS-CoV-2-laden aerosols from the interpersonal breathing microenvironment is dependent on the limited space air stability conditions. Appropriate ventilation method should be implemented based on an evaluation of the air condition. It is recommended that total volume ventilation methods are suitable for unstable and neutral conditions and local ventilation methods are preferable for stable conditions. This study provides an insight into the transmission of airborne SARS-CoV-2-laden aerosols between persons in ventilated rooms with different limited space air stability conditions. Useful guidance has been provided to cope with COVID-19 in limited spaces.
Collapse
Affiliation(s)
- Xiaorui Deng
- College of Civil Engineering, Hunan University, Changsha 410082, China; Key Laboratory of Building Safety and Energy Efficiency, Ministry of Education, Hunan University, Changsha 410082, China
| | - Guangcai Gong
- College of Civil Engineering, Hunan University, Changsha 410082, China; Key Laboratory of Building Safety and Energy Efficiency, Ministry of Education, Hunan University, Changsha 410082, China.
| | - Xizhi He
- College of Civil Engineering, Hunan University, Changsha 410082, China; Key Laboratory of Building Safety and Energy Efficiency, Ministry of Education, Hunan University, Changsha 410082, China
| | - Xing Shi
- College of Civil Engineering, Hunan University, Changsha 410082, China; Key Laboratory of Building Safety and Energy Efficiency, Ministry of Education, Hunan University, Changsha 410082, China
| | - Lan Mo
- Yiyang Engineering Co., Ltd., Yiyang 413000, China
| |
Collapse
|
139
|
Spang RP, Pieper K. The tiny effects of respiratory masks on physiological, subjective, and behavioral measures under mental load in a randomized controlled trial. Sci Rep 2021; 11:19601. [PMID: 34599253 PMCID: PMC8486780 DOI: 10.1038/s41598-021-99100-7] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2020] [Accepted: 09/20/2021] [Indexed: 02/08/2023] Open
Abstract
Since the outbreak of the coronavirus disease (COVID-19), face coverings are recommended to diminish person-to-person transmission of the SARS-CoV-2 virus. Some public debates concern claims regarding risks caused by wearing face masks, like, e.g., decreased blood oxygen levels and impaired cognitive capabilities. The present, pre-registered study aims to contribute clarity by delivering a direct comparison of wearing an N95 respirator and wearing no face covering. We focused on a demanding situation to show that cognitive efficacy and individual states are equivalent in both conditions. We conducted a randomized-controlled crossover trial with 44 participants. Participants performed the task while wearing an N95 FFR versus wearing none. We measured physiological (blood oxygen saturation and heart rate variability), behavioral (parameters of performance in the task), and subjective (perceived mental load) data to substantiate our assumption as broadly as possible. We analyzed data regarding both statistical equivalence and differences. All of the investigated dimensions showed statistical equivalence given our pre-registered equivalence boundaries. None of the dimensions showed a significant difference between wearing an FFR and not wearing an FFR.Trial Registration: Preregistered with the Open Science Framework: https://osf.io/c2xp5 (15/11/2020). Retrospectively registered with German Clinical Trials Register: DRKS00024806 (18/03/2021).
Collapse
Affiliation(s)
- Robert P Spang
- Quality and Usability Lab, Institute of Software Engineering and Theoretical Computer Science, Electrical Engineering and Computer Science, Technical University of Berlin, Berlin, Germany.
| | - Kerstin Pieper
- Quality and Usability Lab, Institute of Software Engineering and Theoretical Computer Science, Electrical Engineering and Computer Science, Technical University of Berlin, Berlin, Germany
| |
Collapse
|
140
|
Abstract
Limiting exposure to severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) virus has been the major principle guiding public health measures. Masking, social distancing, as well as frequent hand hygiene have been the chief nonpharmaceutical interventions as preventive strategies for all age groups. Advancement in vaccine development and vaccination of large populations offer a glimmer of hope for containing and ending this pandemic. However, until immunization is widespread in the community, masking, social distancing, and frequent handwashing, as well as early detection and isolation of infected persons, should be continued to curb the spread of illness.
Collapse
Affiliation(s)
- Shipra Gupta
- West Virginia University School of Medicine, One Medical Center Drive, HSC 9214, Morgantown, WV 26506, USA.
| | - Layne Smith
- West Virginia University School of Pharmacy, One Medical Center Drive, Morgantown, WV 26506, USA
| | - Adriana Diakiw
- West Virginia University School of Medicine, One Medical Center Drive, HSC 9214, Morgantown, WV 26506, USA
| |
Collapse
|
141
|
Nix E, Taylor J, Das P, Ucci M, Chalabi Z, Shrubsole C, Davies M, Mavrogianni A, Milner J, Wilkinson P. Housing, health and energy: a characterisation of risks and priorities across Delhi's diverse settlements. CITIES & HEALTH 2021; 5:298-319. [PMID: 39411509 PMCID: PMC7616699 DOI: 10.1080/23748834.2020.1800161] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/01/2019] [Accepted: 07/16/2020] [Indexed: 10/19/2024]
Abstract
Improved housing has the potential to advance health and contribute to the Sustainable Development Goals. Research examining housing, health and energy use in low-income countries is limited; understanding these connections is vital to inform interventions for healthy sustainable human settlements. This paper investigates the low-income setting of Delhi, where rapid urbanisation, a varied climate, high pollution levels, and a wide variation in housing quality could result in significant energy use and health risks. Drawing on approaches from health and the built environment and existing data and literature, a characterisation of energy use and health risks for Delhi's housing stock is completed. Four broad settlement types were used to classify Delhi housing and energy use calculations and health risk assessment were performed for each variant. Energy use is estimated to be nearly two times higher per household among planned housing compared with other settlement types. Health risks, however, are found to be largest within informal slum settlements, with important contributions from heat and particulate matter across all settlements. This paper highlights intervention priorities and outlines the need for extensive further research, particularly through data gathering, to establish evidence to accelerate achieving healthy, sustainable and equitable housing in Delhi.
Collapse
Affiliation(s)
- Emily Nix
- UCL Institute for Environmental Design and Engineering, University College London, London, UK
| | - Jonathon Taylor
- UCL Institute for Environmental Design and Engineering, University College London, London, UK
- Department of Civil Engineering, Tampere University, Tampere, Finland
| | - Payel Das
- UCL Institute for Environmental Design and Engineering, University College London, London, UK
- Department of Physics, University of Surrey, Guildford, UK
| | - Marcella Ucci
- UCL Institute for Environmental Design and Engineering, University College London, London, UK
| | - Zaid Chalabi
- UCL Institute for Environmental Design and Engineering, University College London, London, UK
- Department of Public Health, Environments and Society, London School of Hygiene and Tropical Medicine, London, UK
| | - Clive Shrubsole
- UCL Institute for Environmental Design and Engineering, University College London, London, UK
- Air Quality & Public Health Group, Environmental Hazards and Emergencies Dept, Centre for Radiation, Chemical and Environmental Hazards, Public Health England, Chilton, UK
| | - Michael Davies
- UCL Institute for Environmental Design and Engineering, University College London, London, UK
| | - Anna Mavrogianni
- UCL Institute for Environmental Design and Engineering, University College London, London, UK
| | - James Milner
- Department of Public Health, Environments and Society, London School of Hygiene and Tropical Medicine, London, UK
- Centre on Climate Change and Planetary Health, London School of Hygiene & Tropical Medicine, London, UK
| | - Paul Wilkinson
- Department of Public Health, Environments and Society, London School of Hygiene and Tropical Medicine, London, UK
- Centre on Climate Change and Planetary Health, London School of Hygiene & Tropical Medicine, London, UK
| |
Collapse
|
142
|
Naunheim MR, Bock J, Doucette PA, Hoch M, Howell I, Johns MM, Johnson AM, Krishna P, Meyer D, Milstein CF, Nix J, Pitman MJ, Robinson-Martin T, Rubin AD, Sataloff RT, Sims HS, Titze IR, Carroll TL. Safer Singing During the SARS-CoV-2 Pandemic: What We Know and What We Don't. J Voice 2021; 35:765-771. [PMID: 32753296 PMCID: PMC7330568 DOI: 10.1016/j.jvoice.2020.06.028] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2020] [Revised: 06/28/2020] [Accepted: 06/29/2020] [Indexed: 01/12/2023]
Affiliation(s)
| | | | | | | | | | | | | | | | | | | | - John Nix
- University of Texas at San Antonio, San Antonio, TX
| | | | | | | | | | | | | | | |
Collapse
|
143
|
Alkalamouni H, Hitti E, Zaraket H. Adopting fresh air ventilation may reduce the risk of airborne transmission of SARS-CoV-2 in COVID-19 unit. J Infect 2021; 83:e4-e5. [PMID: 34480889 PMCID: PMC8409050 DOI: 10.1016/j.jinf.2021.08.046] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2021] [Accepted: 08/31/2021] [Indexed: 11/07/2022]
Affiliation(s)
- Habib Alkalamouni
- Department of Experiment Pathology, Immunology, and Microbiology, Faculty of Medicine, American University of Beirut, Beirut, Lebanon; Center for Infectious Diseases Research (CIDR), Faculty of Medicine, American University of Beirut, Beirut, Lebanon
| | - Eveline Hitti
- Department of Emergency Medicine, Faculty of Medicine, American University of Beirut, Beirut, Lebanon
| | - Hassan Zaraket
- Department of Experiment Pathology, Immunology, and Microbiology, Faculty of Medicine, American University of Beirut, Beirut, Lebanon; Center for Infectious Diseases Research (CIDR), Faculty of Medicine, American University of Beirut, Beirut, Lebanon.
| |
Collapse
|
144
|
Stabile L, Pacitto A, Mikszewski A, Morawska L, Buonanno G. Ventilation procedures to minimize the airborne transmission of viruses in classrooms. BUILDING AND ENVIRONMENT 2021; 202:108042. [PMID: 34127877 PMCID: PMC8189751 DOI: 10.1016/j.buildenv.2021.108042] [Citation(s) in RCA: 43] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Revised: 05/04/2021] [Accepted: 06/05/2021] [Indexed: 05/13/2023]
Abstract
Reducing the transmission of SARS-CoV-2 through indoor air is the key challenge of the COVID-19 pandemic. Crowded indoor environments, such as schools, represent possible hotspots for virus transmission since the basic non-pharmaceutical mitigation measures applied so far (e.g. social distancing) do not eliminate the airborne transmission mode. There is widespread consensus that improved ventilation is needed to minimize the transmission potential of airborne viruses in schools, whether through mechanical systems or ad-hoc manual airing procedures in naturally ventilated buildings. However, there remains significant uncertainty surrounding exactly what ventilation rates are required, and how to best achieve these targets with limited time and resources. This paper uses a mass balance approach to quantify the ability of both mechanical ventilation and ad-hoc airing procedures to mitigate airborne transmission risk in the classroom environment. For naturally-ventilated classrooms, we propose a novel feedback control strategy using CO2 concentrations to continuously monitor and adjust the airing procedure. Our case studies show how such procedures can be applied in the real world to support the reopening of schools during the pandemic. Our results also show the inadequacy of relying on absolute CO2 concentration thresholds as the sole indicator of airborne transmission risk.
Collapse
Affiliation(s)
- L Stabile
- Department of Civil and Mechanical Engineering, University of Cassino and Southern Lazio, Cassino, FR, Italy
| | - A Pacitto
- Department of Civil and Mechanical Engineering, University of Cassino and Southern Lazio, Cassino, FR, Italy
| | - A Mikszewski
- International Laboratory for Air Quality and Health, Queensland University of Technology, Brisbane, Qld, Australia
| | - L Morawska
- International Laboratory for Air Quality and Health, Queensland University of Technology, Brisbane, Qld, Australia
| | - G Buonanno
- Department of Civil and Mechanical Engineering, University of Cassino and Southern Lazio, Cassino, FR, Italy
- International Laboratory for Air Quality and Health, Queensland University of Technology, Brisbane, Qld, Australia
| |
Collapse
|
145
|
Wang CC, Prather KA, Sznitman J, Jimenez JL, Lakdawala SS, Tufekci Z, Marr LC. Airborne transmission of respiratory viruses. Science 2021; 373:eabd9149. [PMID: 34446582 PMCID: PMC8721651 DOI: 10.1126/science.abd9149] [Citation(s) in RCA: 634] [Impact Index Per Article: 158.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
The COVID-19 pandemic has revealed critical knowledge gaps in our understanding of and a need to update the traditional view of transmission pathways for respiratory viruses. The long-standing definitions of droplet and airborne transmission do not account for the mechanisms by which virus-laden respiratory droplets and aerosols travel through the air and lead to infection. In this Review, we discuss current evidence regarding the transmission of respiratory viruses by aerosols-how they are generated, transported, and deposited, as well as the factors affecting the relative contributions of droplet-spray deposition versus aerosol inhalation as modes of transmission. Improved understanding of aerosol transmission brought about by studies of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection requires a reevaluation of the major transmission pathways for other respiratory viruses, which will allow better-informed controls to reduce airborne transmission.
Collapse
Affiliation(s)
- Chia C Wang
- Department of Chemistry, National Sun Yat-sen University, Kaohsiung, Taiwan 804, Republic of China.
- Scripps Institution of Oceanography, University of California San Diego, La Jolla, CA 92037, USA
- Aerosol Science Research Center, National Sun Yat-sen University, Kaohsiung, Taiwan 804, Republic of China
- Department of Chemistry, National Sun Yat-sen University, Kaohsiung, Taiwan 804, Republic of China
| | - Kimberly A Prather
- Scripps Institution of Oceanography, University of California San Diego, La Jolla, CA 92037, USA.
| | - Josué Sznitman
- Department of Biomedical Engineering, Israel Institute of Technology, Haifa 32000, Israel
| | - Jose L Jimenez
- Department of Biomedical Engineering, Israel Institute of Technology, Haifa 32000, Israel
- Department of Chemistry and CIRES, University of Colorado, Boulder, CO 80309, USA
| | - Seema S Lakdawala
- Department of Microbiology and Molecular Genetics, University of Pittsburgh School of Medicine, Pittsburgh, PA 15219, USA
| | - Zeynep Tufekci
- School of Information and Department of Sociology, University of North Carolina, Chapel Hill, NC 27599, USA
| | - Linsey C Marr
- Aerosol Science Research Center, National Sun Yat-sen University, Kaohsiung, Taiwan 804, Republic of China
- Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, VA 24061, USA
| |
Collapse
|
146
|
Wang CC, Prather KA, Sznitman J, Jimenez JL, Lakdawala SS, Tufekci Z, Marr LC. Airborne transmission of respiratory viruses. Science 2021. [PMID: 34446582 DOI: 10.1126/science:abd9149] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/28/2023]
Abstract
The COVID-19 pandemic has revealed critical knowledge gaps in our understanding of and a need to update the traditional view of transmission pathways for respiratory viruses. The long-standing definitions of droplet and airborne transmission do not account for the mechanisms by which virus-laden respiratory droplets and aerosols travel through the air and lead to infection. In this Review, we discuss current evidence regarding the transmission of respiratory viruses by aerosols-how they are generated, transported, and deposited, as well as the factors affecting the relative contributions of droplet-spray deposition versus aerosol inhalation as modes of transmission. Improved understanding of aerosol transmission brought about by studies of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection requires a reevaluation of the major transmission pathways for other respiratory viruses, which will allow better-informed controls to reduce airborne transmission.
Collapse
Affiliation(s)
- Chia C Wang
- Department of Chemistry, National Sun Yat-sen University, Kaohsiung, Taiwan 804, Republic of China.
- Scripps Institution of Oceanography, University of California San Diego, La Jolla, CA 92037, USA
- Aerosol Science Research Center, National Sun Yat-sen University, Kaohsiung, Taiwan 804, Republic of China
- Department of Chemistry, National Sun Yat-sen University, Kaohsiung, Taiwan 804, Republic of China
| | - Kimberly A Prather
- Scripps Institution of Oceanography, University of California San Diego, La Jolla, CA 92037, USA.
| | - Josué Sznitman
- Department of Biomedical Engineering, Israel Institute of Technology, Haifa 32000, Israel
| | - Jose L Jimenez
- Department of Biomedical Engineering, Israel Institute of Technology, Haifa 32000, Israel
- Department of Chemistry and CIRES, University of Colorado, Boulder, CO 80309, USA
| | - Seema S Lakdawala
- Department of Microbiology and Molecular Genetics, University of Pittsburgh School of Medicine, Pittsburgh, PA 15219, USA
| | - Zeynep Tufekci
- School of Information and Department of Sociology, University of North Carolina, Chapel Hill, NC 27599, USA
| | - Linsey C Marr
- Aerosol Science Research Center, National Sun Yat-sen University, Kaohsiung, Taiwan 804, Republic of China
- Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, VA 24061, USA
| |
Collapse
|
147
|
COVID-19 Impact on Operation and Energy Consumption of Heating, Ventilation and Air-Conditioning (HVAC) Systems. ADVANCES IN APPLIED ENERGY 2021; 3. [PMCID: PMC8166037 DOI: 10.1016/j.adapen.2021.100040] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Heating, ventilation and air-conditioning (HVAC) system is favourable for regulating indoor temperature, relative humidity, airflow pattern and air quality. However, HVAC systems may turn out to be the culprit of microbial contamination in enclosed spaces and deteriorate the environment due to inappropriate design and operation. In the context of COVID-19, significant transformations and new requirements are occurring in HVAC systems. Recently, several updated operational guidelines for HVAC systems have been issued by various institutions to control the airborne transmission and mitigate infection risks in enclosed environments. Challenges and innovations emerge in response to operational variations of HVAC systems. To efficiently prevent the spread of the pandemic and reduce infection risks, it is essential to have an overall understanding of impacts caused by COVID-19 on HVAC systems. Therefore, the objectives of this article are to: (a) provide a comprehensive review of the airborne transmission characteristics of SARS-CoV-2 in enclosed spaces and a theoretical basis for HVAC operation guideline revision; (b) investigate HVAC-related guidelines to clarify the operational variations of HVAC systems during the pandemic; (c) analyse how operational variations of HVAC systems affect energy consumption; and (d) identify the innovations and research trends concerning future HVAC systems. Furthermore, this paper compares the energy consumption of HVAC system operation during the normal times versus pandemic period, based on a case study in China, providing a reference for other countries around the world. Results of this paper offer comprehensive insights into how to keep indoor environments safe while maintaining energy-efficient operation of HVAC systems.
Collapse
Key Words
- energy impacts of hvac systems
- covid-19 pandemic
- airborne transmission
- hvac operation guidelines
- challenges and innovations
- ahu, air handing unit
- asc, architectural society of china
- ashrae, american society of heating refrigerating and air-conditioning engineers
- car, chinese association of refrigeration
- cciaq, canadian committee on indoor air quality
- cop, coefficient of performance
- dcv, demand-controlled ventilation
- ecdc, european centre for disease prevention and control
- eeaf, electrostatic enhanced air filter
- eepf, electrostatic enhanced pleated air filters
- hepa, high efficiency particulate air
- hphe, heat pipe heat exchanger
- epa, environmental protection agency
- hvac, heating, ventilation and air-conditioning
- ishrae, indian society of heating refrigerating and air conditioning engineers
- merv, minimum efficiency reporting value
- mohurd, ministry of housing and urban-rural development of the people's republic of china
- nhc, national health commission of china
- pho, public health ontario
- rehva, federation of european heating ventilation and air conditioning associations
- sac, standardization administration of the people's republic of china
- sbs, sick building syndrome
- shase, society of heating air-conditioning and sanitary engineers in japan
- uv, ultraviolet
- uvgi, ultraviolet germicidal irradiation
- who, world health organization
Collapse
|
148
|
Performance Improvement of a Negative-Pressurized Isolation Room for Infection Control. Healthcare (Basel) 2021; 9:healthcare9081081. [PMID: 34442218 PMCID: PMC8391957 DOI: 10.3390/healthcare9081081] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2021] [Revised: 08/18/2021] [Accepted: 08/20/2021] [Indexed: 02/06/2023] Open
Abstract
Negative-pressurized isolation rooms have been approved effectively and applied widely for infectious patients. However, the outbreak of COVID-19 has led to a huge demand for negative-pressurized isolation rooms. It is critical and essential to ensure infection control performance through best practice of ventilation systems and optimum airflow distribution within isolation rooms. This study investigates a retrofitting project of an isolation room to accommodate COVID-19 patients. The field measurement has been conducted to ensure the compliance with the design specification from the CDC of Taiwan. The pressure differentials between negative-pressurized isolation rooms and corridor areas should be at least 8 Pa, while the air change rate per hour (ACH) should be 8–12 times. Computational fluid dynamics (CFD) is applied to evaluate the ventilation performance and contamination control. Different layout arrangements of exhaust air have been proposed to enhance the ventilation performance for infection control. A simple projected air-jet curtain has been proposed in the simulation model to enhance extra protection of medical staff. The resulting ventilation control revealed that the contamination control can be improved through the minor adjustment of exhaust air arrangement and the application of an air-jet curtain.
Collapse
|
149
|
CFD Analyses: The Effect of Pressure Suction and Airflow Velocity on Coronavirus Dispersal. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app11167450] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Hospital emergency departments (EDs) are hubs for highly transmissible infectious diseases, posing the highest risk of viral infection transmission. With the current COVID-19 outbreak, it has become clear that the ED design needs to be altered in order to be successful in containing the pandemic. The purpose of this study is to use a computational fluid dynamics (CFD) simulation to evaluate the ventilation system design for an emergency department at a university hospital. The kinetic energy and velocity patterns of turbulence were analyzed to determine which areas of the ED were most susceptible to viral transmission. Additionally, the impact of pressure suction on COVID-19 dispersion has been investigated. Three critical areas of the ED, overnight patient beds, surgical rooms, and resuscitation rooms, all had much higher air velocity, dispersion, and mixing levels than the rest of the department’s spaces, according to the simulation findings. Air transmission from these sites to adjacent regions is a possibility in the scenario studied, increasing the likelihood of the virus spreading from these locations and infecting people in the surrounding areas. The results of these simulations may be utilized to provide recommendations to the hospital administration about the placement of inlets and outlets, the separation of areas, and the interior design of the spaces and corridors.
Collapse
|
150
|
Wessling EG, Randolph AH, Neill LA, Gandhi KR, Conrardy M, Chodakowski JD, Kippenhan M, Loftus TM, Malik S. Rapid Emergency Department Physical Space Modifications for COVID-19: Keeping Patients and Health Care Workers Safe. Disaster Med Public Health Prep 2021; 16:1-4. [PMID: 34346305 PMCID: PMC8446594 DOI: 10.1017/dmp.2021.248] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2020] [Revised: 06/15/2021] [Accepted: 07/24/2021] [Indexed: 12/15/2022]
Abstract
The COVID-19 pandemic has placed significant strain on emergency departments (EDs) that were not designed to care for many patients who may be highly contagious. This report outlines how a busy urban ED was adapted to prepare for COVID-19 via 3 primary interventions: (1) creating an open-air care space in the ambulance bay to cohort, triage, and rapidly test patients with suspected COVID-19, (2) quickly constructing temporary doors on all open treatment rooms, and (3) adapting and expanding the waiting room. This description serves as a model by which other EDs can repurpose their own care spaces to help ensure safety of their patients and health care workers.
Collapse
Affiliation(s)
- Emily G Wessling
- Department of Emergency Medicine, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| | - Amanda H Randolph
- Department of Emergency Medicine, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| | - Luke A Neill
- Department of Emergency Medicine, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| | - Kumar R Gandhi
- Department of Emergency Medicine, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| | - Michael Conrardy
- Department of Emergency Medicine, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| | - Jason D Chodakowski
- Department of Emergency Medicine, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| | - Matthew Kippenhan
- Department of Emergency Medicine, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| | - Timothy M Loftus
- Department of Emergency Medicine, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| | - Sanjeev Malik
- Department of Emergency Medicine, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| |
Collapse
|