1
|
Anand S, Lustig M. Beat Pilot Tone (BPT): Simultaneous MRI and RF motion sensing at arbitrary frequencies. Magn Reson Med 2024; 92:1768-1787. [PMID: 38872443 DOI: 10.1002/mrm.30150] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2023] [Revised: 04/13/2024] [Accepted: 04/23/2024] [Indexed: 06/15/2024]
Abstract
PURPOSE To introduce a simple system exploitation with the potential to turn MRI scanners into general-purpose radiofrequency (RF) motion monitoring systems. METHODS Inspired by Pilot Tone (PT), this work proposes Beat Pilot Tone (BPT), in which two or more RF tones at arbitrary frequencies are transmitted continuously during the scan. These tones create motion-modulated standing wave patterns that are sensed by the receiver coil array, incidentally mixed by intermodulation in the receiver chain, and digitized simultaneously with the MRI data. BPT can operate at almost any frequency as long as the intermodulation products lie within the bandwidth of the receivers. BPT's mechanism is explained in electromagnetic simulations and validated experimentally. RESULTS Phantom and volunteer experiments over a range of transmit frequencies suggest that BPT may offer frequency-dependent sensitivity to motion. Using a semi-flexible anterior receiver array, BPT appears to sense cardiac-induced body vibrations at microwave frequencies (≥ $$ \ge $$ 1.2 GHz). At lower frequencies, it exhibits a similar cardiac signal shape to PT, likely due to blood volume changes. Other volunteer experiments with respiratory, bulk, and head motion show that BPT can achieve greater sensitivity to motion than PT and greater separability between motion types. Basic multiple-input multiple-output (4 × 22 $$ 4\times 22 $$ MIMO) operation with simultaneous PT and BPT in head motion is demonstrated using two transmit antennas and a 22-channel head-neck coil. CONCLUSION BPT may offer a rich source of motion information that is frequency-dependent, simultaneous, and complementary to PT and the MRI exam.
Collapse
Affiliation(s)
- Suma Anand
- Electrical Engineering and Computer Sciences, University of California, Berkeley, California
| | - Michael Lustig
- Electrical Engineering and Computer Sciences, University of California, Berkeley, California
| |
Collapse
|
2
|
Zhao B, Zhou Y, Zong X. Effects of prospective motion correction on perivascular spaces at 7T MRI evaluated using motion artifact simulation. Magn Reson Med 2024; 92:1079-1094. [PMID: 38651650 PMCID: PMC11209793 DOI: 10.1002/mrm.30126] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2024] [Revised: 03/12/2024] [Accepted: 04/04/2024] [Indexed: 04/25/2024]
Abstract
PURPOSE The effectiveness of prospective motion correction (PMC) is often evaluated by comparing artifacts in images acquired with and without PMC (NoPMC). However, such an approach is not applicable in clinical setting due to unavailability of NoPMC images. We aim to develop a simulation approach for demonstrating the ability of fat-navigator-based PMC in improving perivascular space (PVS) visibility in T2-weighted MRI. METHODS MRI datasets from two earlier studies were used for motion artifact simulation and evaluating PMC, including T2-weighted NoPMC and PMC images. To simulate motion artifacts, k-space data at motion-perturbed positions were calculated from artifact-free images using nonuniform Fourier transform and misplaced onto the Cartesian grid before inverse Fourier transform. The simulation's ability to reproduce motion-induced blurring, ringing, and ghosting artifacts was evaluated using sharpness at lateral ventricle/white matter boundary, ringing artifact magnitude in the Fourier spectrum, and background noise, respectively. PVS volume fraction in white matter was employed to reflect its visibility. RESULTS In simulation, sharpness, PVS volume fraction, and background noise exhibited significant negative correlations with motion score. Significant correlations were found in sharpness, ringing artifact magnitude, and PVS volume fraction between simulated and real NoPMC images (p ≤ 0.006). In contrast, such correlations were reduced and nonsignificant between simulated and real PMC images (p ≥ 0.48), suggesting reduction of motion effects with PMC. CONCLUSIONS The proposed simulation approach is an effective tool to study the effects of motion and PMC on PVS visibility. PMC may reduce the systematic bias of PVS volume fraction caused by motion artifacts.
Collapse
Affiliation(s)
- Bingbing Zhao
- School of Biomedical Engineering & State Key Laboratory of Advanced Medical Materials and Devices, ShanghaiTech University, Shanghai 201210, China
| | - Yichen Zhou
- School of Biomedical Engineering & State Key Laboratory of Advanced Medical Materials and Devices, ShanghaiTech University, Shanghai 201210, China
| | - Xiaopeng Zong
- School of Biomedical Engineering & State Key Laboratory of Advanced Medical Materials and Devices, ShanghaiTech University, Shanghai 201210, China
| |
Collapse
|
3
|
Fraum TJ, An H. Invited Commentary: New Motion Mitigation Strategies for T1-weighted Abdominal MRI-Time to Breathe a Sigh of Relief? Radiographics 2024; 44:e230242. [PMID: 38990777 DOI: 10.1148/rg.230242] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/13/2024]
Affiliation(s)
- Tyler J Fraum
- From the Mallinckrodt Institute of Radiology, Washington University School of Medicine; 510 S Kingshighway Blvd, Campus Box 8131, St Louis, MO 63110
| | - Hongyu An
- From the Mallinckrodt Institute of Radiology, Washington University School of Medicine; 510 S Kingshighway Blvd, Campus Box 8131, St Louis, MO 63110
| |
Collapse
|
4
|
Levac B, Kumar S, Jalal A, Tamir JI. Accelerated motion correction with deep generative diffusion models. Magn Reson Med 2024; 92:853-868. [PMID: 38688874 DOI: 10.1002/mrm.30082] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2023] [Revised: 01/02/2024] [Accepted: 02/23/2024] [Indexed: 05/02/2024]
Abstract
PURPOSE The aim of this work is to develop a method to solve the ill-posed inverse problem of accelerated image reconstruction while correcting forward model imperfections in the context of subject motion during MRI examinations. METHODS The proposed solution uses a Bayesian framework based on deep generative diffusion models to jointly estimate a motion-free image and rigid motion estimates from subsampled and motion-corrupt two-dimensional (2D) k-space data. RESULTS We demonstrate the ability to reconstruct motion-free images from accelerated two-dimensional (2D) Cartesian and non-Cartesian scans without any external reference signal. We show that our method improves over existing correction techniques on both simulated and prospectively accelerated data. CONCLUSION We propose a flexible framework for retrospective motion correction of accelerated MRI based on deep generative diffusion models, with potential application to other forward model corruptions.
Collapse
Affiliation(s)
- Brett Levac
- Chandra Family Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, Texas, USA
| | - Sidharth Kumar
- Chandra Family Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, Texas, USA
| | - Ajil Jalal
- Electrical Engineering and Computer Sciences, University of California at Berkeley, Berkeley, California, USA
| | - Jonathan I Tamir
- Chandra Family Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, Texas, USA
| |
Collapse
|
5
|
Zhang D, Han Q, Xiong Y, Du H. Mutli-modal straight flow matching for accelerated MR imaging. Comput Biol Med 2024; 178:108668. [PMID: 38870720 DOI: 10.1016/j.compbiomed.2024.108668] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2024] [Revised: 04/05/2024] [Accepted: 05/26/2024] [Indexed: 06/15/2024]
Abstract
Diffusion models have garnered great interest lately in Magnetic Resonance (MR) image reconstruction. A key component of generating high-quality samples from noise is iterative denoising for thousands of steps. However, the complexity of inference steps has limited its applications. To solve the challenge in obtaining high-quality reconstructed images with fewer inference steps and computational complexity, we introduce a novel straight flow matching, based on a neural ordinary differential equation (ODE) generative model. Our model creates a linear path between undersampled images and reconstructed images, which can be accurately simulated with a few Euler steps. Furthermore, we propose a multi-modal straight flow matching model, which uses relatively easily available modalities as supplementary information to guide the reconstruction of target modalities. We introduce the low frequency fusion layer and the high frequency fusion layer into our multi-modal model, which has been proved to produce promising results in fusion tasks. The proposed multi-modal straight flow matching (MMSflow) achieves state-of-the-art performances in task of reconstruction in fastMRI and Brats-2020 and improves the sampling rate by an order of magnitude than other methods based on stochastic differential equations (SDE).
Collapse
Affiliation(s)
- Daikun Zhang
- University of Science and Technology of China, Hefei, Anhui 230026, China.
| | - Qiuyi Han
- University of Science and Technology of China, Hefei, Anhui 230026, China.
| | - Yuzhu Xiong
- University of Science and Technology of China, Hefei, Anhui 230026, China.
| | - Hongwei Du
- University of Science and Technology of China, Hefei, Anhui 230026, China.
| |
Collapse
|
6
|
Heckel R, Jacob M, Chaudhari A, Perlman O, Shimron E. Deep learning for accelerated and robust MRI reconstruction. MAGMA (NEW YORK, N.Y.) 2024:10.1007/s10334-024-01173-8. [PMID: 39042206 DOI: 10.1007/s10334-024-01173-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/03/2024] [Revised: 05/24/2024] [Accepted: 05/28/2024] [Indexed: 07/24/2024]
Abstract
Deep learning (DL) has recently emerged as a pivotal technology for enhancing magnetic resonance imaging (MRI), a critical tool in diagnostic radiology. This review paper provides a comprehensive overview of recent advances in DL for MRI reconstruction, and focuses on various DL approaches and architectures designed to improve image quality, accelerate scans, and address data-related challenges. It explores end-to-end neural networks, pre-trained and generative models, and self-supervised methods, and highlights their contributions to overcoming traditional MRI limitations. It also discusses the role of DL in optimizing acquisition protocols, enhancing robustness against distribution shifts, and tackling biases. Drawing on the extensive literature and practical insights, it outlines current successes, limitations, and future directions for leveraging DL in MRI reconstruction, while emphasizing the potential of DL to significantly impact clinical imaging practices.Affiliations [3 and 6] has been split into two different affiliations. Please check if action taken is appropriate and amend if necessary.looks good.
Collapse
Affiliation(s)
- Reinhard Heckel
- Department of computer engineering, Technical University of Munich, Munich, Germany
| | - Mathews Jacob
- Department of Electrical and Computer Engineering, University of Iowa, Iowa, 52242, IA, USA
| | - Akshay Chaudhari
- Department of Radiology, Stanford University, Stanford, 94305, CA, USA
- Department of Biomedical Data Science, Stanford University, Stanford, 94305, CA, USA
| | - Or Perlman
- Department of Biomedical Engineering, Tel Aviv University, Tel Aviv, Israel
- Sagol School of Neuroscience, Tel Aviv University, Tel Aviv, Israel
| | - Efrat Shimron
- Department of Electrical and Computer Engineering, Technion-Israel Institute of Technology, Haifa, 3200004, Israel.
- Department of Biomedical Engineering, Technion-Israel Institute of Technology, Haifa, 3200004, Israel.
| |
Collapse
|
7
|
Shih SF, Wu HH. Free-breathing MRI techniques for fat and R 2* quantification in the liver. MAGMA (NEW YORK, N.Y.) 2024:10.1007/s10334-024-01187-2. [PMID: 39039272 DOI: 10.1007/s10334-024-01187-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Revised: 05/18/2024] [Accepted: 07/02/2024] [Indexed: 07/24/2024]
Abstract
OBJECTIVE To review the recent advancements in free-breathing MRI techniques for proton-density fat fraction (PDFF) and R2* quantification in the liver, and discuss the current challenges and future opportunities. MATERIALS AND METHODS This work focused on recent developments of different MRI pulse sequences, motion management strategies, and reconstruction approaches that enable free-breathing liver PDFF and R2* quantification. RESULTS Different free-breathing liver PDFF and R2* quantification techniques have been evaluated in various cohorts, including healthy volunteers and patients with liver diseases, both in adults and children. Initial results demonstrate promising performance with respect to reference measurements. These techniques have a high potential impact on providing a solution to the clinical need of accurate liver fat and iron quantification in populations with limited breath-holding capacity. DISCUSSION As these free-breathing techniques progress toward clinical translation, studies of the linearity, bias, and repeatability of free-breathing PDFF and R2* quantification in a larger cohort are important. Scan acceleration and improved motion management also hold potential for further enhancement.
Collapse
Affiliation(s)
- Shu-Fu Shih
- Department of Radiological Sciences, University of California Los Angeles, Los Angeles, CA, USA
- Department of Bioengineering, University of California Los Angeles, Los Angeles, CA, USA
| | - Holden H Wu
- Department of Radiological Sciences, University of California Los Angeles, Los Angeles, CA, USA.
- Department of Bioengineering, University of California Los Angeles, Los Angeles, CA, USA.
| |
Collapse
|
8
|
Liebert A, Das BK, Kapsner LA, Eberle J, Skwierawska D, Folle L, Schreiter H, Laun FB, Ohlmeyer S, Uder M, Wenkel E, Bickelhaupt S. Smart forecasting of artifacts in contrast-enhanced breast MRI before contrast agent administration. Eur Radiol 2024; 34:4752-4763. [PMID: 38099964 PMCID: PMC11213750 DOI: 10.1007/s00330-023-10469-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2023] [Revised: 10/05/2023] [Accepted: 10/21/2023] [Indexed: 12/21/2023]
Abstract
OBJECTIVES To evaluate whether artifacts on contrast-enhanced (CE) breast MRI maximum intensity projections (MIPs) might already be forecast before gadolinium-based contrast agent (GBCA) administration during an ongoing examination by analyzing the unenhanced T1-weighted images acquired before the GBCA injection. MATERIALS AND METHODS This IRB-approved retrospective analysis consisted of n = 2884 breast CE MRI examinations after intravenous administration of GBCA, acquired with n = 4 different MRI devices at different field strengths (1.5 T/3 T) during clinical routine. CE-derived subtraction MIPs were used to conduct a multi-class multi-reader evaluation of the presence and severity of artifacts with three independent readers. An ensemble classifier (EC) of five DenseNet models was used to predict artifacts for the post-contrast subtraction MIPs, giving as the input source only the pre-contrast T1-weighted sequence. Thus, the acquisition directly preceded the GBCA injection. The area under ROC (AuROC) and diagnostics accuracy scores were used to assess the performance of the neural network in an independent holdout test set (n = 285). RESULTS After majority voting, potentially significant artifacts were detected in 53.6% (n = 1521) of all breast MRI examinations (age 49.6 ± 12.6 years). In the holdout test set (mean age 49.7 ± 11.8 years), at a specificity level of 89%, the EC could forecast around one-third of artifacts (sensitivity 31%) before GBCA administration, with an AuROC = 0.66. CONCLUSION This study demonstrates the capability of a neural network to forecast the occurrence of artifacts on CE subtraction data before the GBCA administration. If confirmed in larger studies, this might enable a workflow-blended approach to prevent breast MRI artifacts by implementing in-scan personalized predictive algorithms. CLINICAL RELEVANCE STATEMENT Some artifacts in contrast-enhanced breast MRI maximum intensity projections might be predictable before gadolinium-based contrast agent injection using a neural network. KEY POINTS • Potentially significant artifacts can be observed in a relevant proportion of breast MRI subtraction sequences after gadolinium-based contrast agent administration (GBCA). • Forecasting the occurrence of such artifacts in subtraction maximum intensity projections before GBCA administration for individual patients was feasible at 89% specificity, which allowed correctly predicting one in three future artifacts. • Further research is necessary to investigate the clinical value of such smart personalized imaging approaches.
Collapse
Affiliation(s)
- Andrzej Liebert
- Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.
| | - Badhan K Das
- Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Lorenz A Kapsner
- Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
- Medical Center for Information and Communication Technology, Universitätsklinikum Erlangen, Erlangen, Germany
| | - Jessica Eberle
- Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Dominika Skwierawska
- Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Lukas Folle
- Pattern Recognition Lab, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Hannes Schreiter
- Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Frederik B Laun
- Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Sabine Ohlmeyer
- Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Michael Uder
- Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Evelyn Wenkel
- Medizinische Fakultät, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
- Radiologie München, München, Germany
| | - Sebastian Bickelhaupt
- Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
- German Cancer Research Center (DKFZ), Heidelberg, Germany
| |
Collapse
|
9
|
Lee J, Seo H, Lee W, Park H. Unsupervised motion artifact correction of turbo spin-echo MRI using deep image prior. Magn Reson Med 2024; 92:28-42. [PMID: 38282279 DOI: 10.1002/mrm.30026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Revised: 12/13/2023] [Accepted: 01/09/2024] [Indexed: 01/30/2024]
Abstract
PURPOSE In MRI, motion artifacts can significantly degrade image quality. Motion artifact correction methods using deep neural networks usually required extensive training on large datasets, making them time-consuming and resource-intensive. In this paper, an unsupervised deep learning-based motion artifact correction method for turbo-spin echo MRI is proposed using the deep image prior framework. THEORY AND METHODS The proposed approach takes advantage of the high impedance to motion artifacts offered by the neural network parameterization to remove motion artifacts in MR images. The framework consists of parameterization of MR image, automatic spatial transformation, and motion simulation model. The proposed method synthesizes motion-corrupted images from the motion-corrected images generated by the convolutional neural network, where an optimization process minimizes the objective function between the synthesized images and the acquired images. RESULTS In the simulation study of 280 slices from 14 subjects, the proposed method showed a significant increase in the averaged structural similarity index measure by 0.2737 in individual coil images and by 0.4550 in the root-sum-of-square images. In addition, the ablation study demonstrated the effectiveness of each proposed component in correcting motion artifacts compared to the corrected images produced by the baseline method. The experiments on real motion dataset has shown its clinical potential. CONCLUSION The proposed method exhibited significant quantitative and qualitative improvements in correcting rigid and in-plane motion artifacts in MR images acquired using turbo spin-echo sequence.
Collapse
Affiliation(s)
- Jongyeon Lee
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, Republic of Korea
- Bionics Research Center, Biomedical Research Division, Korea Institute of Science and Technology (KIST), Seoul, Republic of Korea
| | - Hyunseok Seo
- Bionics Research Center, Biomedical Research Division, Korea Institute of Science and Technology (KIST), Seoul, Republic of Korea
| | - Wonil Lee
- Gordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA
- Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
| | - HyunWook Park
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, Republic of Korea
| |
Collapse
|
10
|
Yasaka K, Akai H, Kato S, Tajima T, Yoshioka N, Furuta T, Kageyama H, Toda Y, Akahane M, Ohtomo K, Abe O, Kiryu S. Iterative Motion Correction Technique with Deep Learning Reconstruction for Brain MRI: A Volunteer and Patient Study. JOURNAL OF IMAGING INFORMATICS IN MEDICINE 2024:10.1007/s10278-024-01184-w. [PMID: 38942939 DOI: 10.1007/s10278-024-01184-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/19/2024] [Revised: 06/03/2024] [Accepted: 06/18/2024] [Indexed: 06/30/2024]
Abstract
The aim of this study was to investigate the effect of iterative motion correction (IMC) on reducing artifacts in brain magnetic resonance imaging (MRI) with deep learning reconstruction (DLR). The study included 10 volunteers (between September 2023 and December 2023) and 30 patients (between June 2022 and July 2022) for quantitative and qualitative analyses, respectively. Volunteers were instructed to remain still during the first MRI with fluid-attenuated inversion recovery sequence (FLAIR) and to move during the second scan. IMCoff DLR images were reconstructed from the raw data of the former acquisition; IMCon and IMCoff DLR images were reconstructed from the latter acquisition. After registration of the motion images, the structural similarity index measure (SSIM) was calculated using motionless images as reference. For qualitative analyses, IMCon and IMCoff FLAIR DLR images of the patients were reconstructed and evaluated by three blinded readers in terms of motion artifacts, noise, and overall quality. SSIM for IMCon images was 0.952, higher than that for IMCoff images (0.949) (p < 0.001). In qualitative analyses, although noise in IMCon images was rated as increased by two of the three readers (both p < 0.001), all readers agreed that motion artifacts and overall quality were significantly better in IMCon images than in IMCoff images (all p < 0.001). In conclusion, IMC reduced motion artifacts in brain FLAIR DLR images while maintaining similarity to motionless images.
Collapse
Affiliation(s)
- Koichiro Yasaka
- Department of Radiology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan
- Department of Radiology, International University of Health and Welfare Narita Hospital, 852 Hatakeda, Narita, Chiba, 286-0124, Japan
| | - Hiroyuki Akai
- Department of Radiology, International University of Health and Welfare Narita Hospital, 852 Hatakeda, Narita, Chiba, 286-0124, Japan
- Department of Radiology, The Institute of Medical Science, The University of Tokyo, 4-6-1 Shirokanedai, Minato-ku, Tokyo, 108-8639, Japan
| | - Shimpei Kato
- Department of Radiology, The Institute of Medical Science, The University of Tokyo, 4-6-1 Shirokanedai, Minato-ku, Tokyo, 108-8639, Japan
| | - Taku Tajima
- Department of Radiology, International University of Health and Welfare Mita Hospital, 1-4-3 Mita, Minato-ku, Tokyo, 108-8329, Japan
| | - Naoki Yoshioka
- Department of Radiology, International University of Health and Welfare Narita Hospital, 852 Hatakeda, Narita, Chiba, 286-0124, Japan
| | - Toshihiro Furuta
- Department of Radiology, The Institute of Medical Science, The University of Tokyo, 4-6-1 Shirokanedai, Minato-ku, Tokyo, 108-8639, Japan
| | - Hajime Kageyama
- Department of Radiology, The Institute of Medical Science, The University of Tokyo, 4-6-1 Shirokanedai, Minato-ku, Tokyo, 108-8639, Japan
| | - Yui Toda
- Department of Radiology, International University of Health and Welfare Narita Hospital, 852 Hatakeda, Narita, Chiba, 286-0124, Japan
| | - Masaaki Akahane
- Department of Radiology, International University of Health and Welfare Narita Hospital, 852 Hatakeda, Narita, Chiba, 286-0124, Japan
| | - Kuni Ohtomo
- International University of Health and Welfare, 2600-1 Ktiakanemaru, Ohtawara, Tochigi, 324-8501, Japan
| | - Osamu Abe
- Department of Radiology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan
| | - Shigeru Kiryu
- Department of Radiology, International University of Health and Welfare Narita Hospital, 852 Hatakeda, Narita, Chiba, 286-0124, Japan.
| |
Collapse
|
11
|
Silic M, Tam F, Graham SJ. Test Platform for Developing New Optical Position Tracking Technology towards Improved Head Motion Correction in Magnetic Resonance Imaging. SENSORS (BASEL, SWITZERLAND) 2024; 24:3737. [PMID: 38931521 PMCID: PMC11207598 DOI: 10.3390/s24123737] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2024] [Revised: 06/03/2024] [Accepted: 06/06/2024] [Indexed: 06/28/2024]
Abstract
Optical tracking of head pose via fiducial markers has been proven to enable effective correction of motion artifacts in the brain during magnetic resonance imaging but remains difficult to implement in the clinic due to lengthy calibration and set up times. Advances in deep learning for markerless head pose estimation have yet to be applied to this problem because of the sub-millimetre spatial resolution required for motion correction. In the present work, two optical tracking systems are described for the development and training of a neural network: one marker-based system (a testing platform for measuring ground truth head pose) with high tracking fidelity to act as the training labels, and one markerless deep-learning-based system using images of the markerless head as input to the network. The markerless system has the potential to overcome issues of marker occlusion, insufficient rigid attachment of the marker, lengthy calibration times, and unequal performance across degrees of freedom (DOF), all of which hamper the adoption of marker-based solutions in the clinic. Detail is provided on the development of a custom moiré-enhanced fiducial marker for use as ground truth and on the calibration procedure for both optical tracking systems. Additionally, the development of a synthetic head pose dataset is described for the proof of concept and initial pre-training of a simple convolutional neural network. Results indicate that the ground truth system has been sufficiently calibrated and can track head pose with an error of <1 mm and <1°. Tracking data of a healthy, adult participant are shown. Pre-training results show that the average root-mean-squared error across the 6 DOF is 0.13 and 0.36 (mm or degrees) on a head model included and excluded from the training dataset, respectively. Overall, this work indicates excellent feasibility of the deep-learning-based approach and will enable future work in training and testing on a real dataset in the MRI environment.
Collapse
Affiliation(s)
- Marina Silic
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, ON M4N 3M5, Canada; (M.S.); (F.T.)
- Department of Medical Biophysics, University of Toronto, Toronto, ON M5G 1L7, Canada
| | - Fred Tam
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, ON M4N 3M5, Canada; (M.S.); (F.T.)
| | - Simon J. Graham
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, ON M4N 3M5, Canada; (M.S.); (F.T.)
- Department of Medical Biophysics, University of Toronto, Toronto, ON M5G 1L7, Canada
| |
Collapse
|
12
|
Tibrewala R, Brantner D, Brown R, Pancoast L, Keerthivasan M, Bruno M, Block KT, Madore B, Sodickson DK, Collins CM. Preliminary Experience with Three Alternative Motion Sensors for 0.55 Tesla MR Imaging. SENSORS (BASEL, SWITZERLAND) 2024; 24:3710. [PMID: 38931494 PMCID: PMC11207459 DOI: 10.3390/s24123710] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/09/2024] [Revised: 05/27/2024] [Accepted: 06/05/2024] [Indexed: 06/28/2024]
Abstract
Due to limitations in current motion tracking technologies and increasing interest in alternative sensors for motion tracking both inside and outside the MRI system, in this study we share our preliminary experience with three alternative sensors utilizing diverse technologies and interactions with tissue to monitor motion of the body surface, respiratory-related motion of major organs, and non-respiratory motion of deep-seated organs. These consist of (1) a Pilot-Tone RF transmitter combined with deep learning algorithms for tracking liver motion, (2) a single-channel ultrasound transducer with deep learning for monitoring bladder motion, and (3) a 3D Time-of-Flight camera for observing the motion of the anterior torso surface. Additionally, we demonstrate the capability of these sensors to simultaneously capture motion data outside the MRI environment, which is particularly relevant for procedures like radiation therapy, where motion status could be related to previously characterized cyclical anatomical data. Our findings indicate that the ultrasound sensor can track motion in deep-seated organs (bladder) as well as respiratory-related motion. The Time-of-Flight camera offers ease of interpretation and performs well in detecting surface motion (respiration). The Pilot-Tone demonstrates efficacy in tracking bulk respiratory motion and motion of major organs (liver). Simultaneous use of all three sensors could provide complementary motion information outside the MRI bore, providing potential value for motion tracking during position-sensitive treatments such as radiation therapy.
Collapse
Affiliation(s)
- Radhika Tibrewala
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY 10016, USA
- Center for Advanced Imaging Innovation and Research (CAIR), Department of Radiology, New York University Grossman School of Medicine, New York, NY 10016, USA
- Vilcek Institute of Graduate Biomedical Sciences, New York University Grossman School of Medicine, New York, NY 10016, USA
| | - Douglas Brantner
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY 10016, USA
- Center for Advanced Imaging Innovation and Research (CAIR), Department of Radiology, New York University Grossman School of Medicine, New York, NY 10016, USA
| | - Ryan Brown
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY 10016, USA
- Center for Advanced Imaging Innovation and Research (CAIR), Department of Radiology, New York University Grossman School of Medicine, New York, NY 10016, USA
- Vilcek Institute of Graduate Biomedical Sciences, New York University Grossman School of Medicine, New York, NY 10016, USA
| | - Leanna Pancoast
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY 10016, USA
- Center for Advanced Imaging Innovation and Research (CAIR), Department of Radiology, New York University Grossman School of Medicine, New York, NY 10016, USA
| | | | - Mary Bruno
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY 10016, USA
- Center for Advanced Imaging Innovation and Research (CAIR), Department of Radiology, New York University Grossman School of Medicine, New York, NY 10016, USA
| | - Kai Tobias Block
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY 10016, USA
- Center for Advanced Imaging Innovation and Research (CAIR), Department of Radiology, New York University Grossman School of Medicine, New York, NY 10016, USA
- Vilcek Institute of Graduate Biomedical Sciences, New York University Grossman School of Medicine, New York, NY 10016, USA
| | - Bruno Madore
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA 02115, USA
| | - Daniel K. Sodickson
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY 10016, USA
- Center for Advanced Imaging Innovation and Research (CAIR), Department of Radiology, New York University Grossman School of Medicine, New York, NY 10016, USA
- Vilcek Institute of Graduate Biomedical Sciences, New York University Grossman School of Medicine, New York, NY 10016, USA
| | - Christopher M. Collins
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY 10016, USA
- Center for Advanced Imaging Innovation and Research (CAIR), Department of Radiology, New York University Grossman School of Medicine, New York, NY 10016, USA
- Vilcek Institute of Graduate Biomedical Sciences, New York University Grossman School of Medicine, New York, NY 10016, USA
| |
Collapse
|
13
|
Valverde S, Coll L, Valencia L, Clèrigues A, Oliver A, Vilanova JC, Ramió-Torrentà L, Rovira À, Lladó X. Assessing the Accuracy and Reproducibility of PARIETAL: A Deep Learning Brain Extraction Algorithm. J Magn Reson Imaging 2024; 59:1991-2000. [PMID: 34137113 DOI: 10.1002/jmri.27776] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2020] [Revised: 05/31/2021] [Accepted: 06/01/2021] [Indexed: 01/18/2023] Open
Abstract
BACKGROUND Manual brain extraction from magnetic resonance (MR) images is time-consuming and prone to intra- and inter-rater variability. Several automated approaches have been developed to alleviate these constraints, including deep learning pipelines. However, these methods tend to reduce their performance in unseen magnetic resonance imaging (MRI) scanner vendors and different imaging protocols. PURPOSE To present and evaluate for clinical use PARIETAL, a pre-trained deep learning brain extraction method. We compare its reproducibility in a scan/rescan analysis and its robustness among scanners of different manufacturers. STUDY TYPE Retrospective. POPULATION Twenty-one subjects (12 women) with age range 22-48 years acquired using three different MRI scanner machines including scan/rescan in each of them. FIELD STRENGTH/SEQUENCE T1-weighted images acquired in a 3-T Siemens with magnetization prepared rapid gradient-echo sequence and two 1.5 T scanners, Philips and GE, with spin-echo and spoiled gradient-recalled (SPGR) sequences, respectively. ASSESSMENT Analysis of the intracranial cavity volumes obtained for each subject on the three different scanners and the scan/rescan acquisitions. STATISTICAL TESTS Parametric permutation tests of the differences in volumes to rank and statistically evaluate the performance of PARIETAL compared to state-of-the-art methods. RESULTS The mean absolute intracranial volume differences obtained by PARIETAL in the scan/rescan analysis were 1.88 mL, 3.91 mL, and 4.71 mL for Siemens, GE, and Philips scanners, respectively. PARIETAL was the best-ranked method on Siemens and GE scanners, while decreasing to Rank 2 on the Philips images. Intracranial differences for the same subject between scanners were 5.46 mL, 27.16 mL, and 30.44 mL for GE/Philips, Siemens/Philips, and Siemens/GE comparison, respectively. The permutation tests revealed that PARIETAL was always in Rank 1, obtaining the most similar volumetric results between scanners. DATA CONCLUSION PARIETAL accurately segments the brain and it generalizes to images acquired at different sites without the need of training or fine-tuning it again. PARIETAL is publicly available. LEVEL OF EVIDENCE 2 TECHNICAL EFFICACY STAGE: 2.
Collapse
Affiliation(s)
- Sergi Valverde
- Research Institute of Computer Vision and Robotics, University of Girona, Girona, Spain
| | - Llucia Coll
- Research Institute of Computer Vision and Robotics, University of Girona, Girona, Spain
| | - Liliana Valencia
- Research Institute of Computer Vision and Robotics, University of Girona, Girona, Spain
| | - Albert Clèrigues
- Research Institute of Computer Vision and Robotics, University of Girona, Girona, Spain
| | - Arnau Oliver
- Research Institute of Computer Vision and Robotics, University of Girona, Girona, Spain
- REEM, Red Española de Esclerosis Múltiple
| | | | - Lluís Ramió-Torrentà
- REEM, Red Española de Esclerosis Múltiple
- Multiple Sclerosis and Neuroimmunology Unit, Neurology Department, Dr. Josep Trueta University Hospital, Institut d'Investigació Biomèdica, Girona, Spain
- Medical Sciences Department, University of Girona, Girona, Spain
| | - Àlex Rovira
- Magnetic Resonance Unit, Department of Radiology, Vall d'Hebron University Hospital, Barcelona, Spain
| | - Xavier Lladó
- Research Institute of Computer Vision and Robotics, University of Girona, Girona, Spain
- REEM, Red Española de Esclerosis Múltiple
| |
Collapse
|
14
|
Safari M, Yang X, Chang CW, Qiu RLJ, Fatemi A, Archambault L. Unsupervised MRI motion artifact disentanglement: introducing MAUDGAN. Phys Med Biol 2024; 69:115057. [PMID: 38714192 DOI: 10.1088/1361-6560/ad4845] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2024] [Accepted: 05/07/2024] [Indexed: 05/09/2024]
Abstract
Objective.This study developed an unsupervised motion artifact reduction method for magnetic resonance imaging (MRI) images of patients with brain tumors. The proposed novel design uses multi-parametric multicenter contrast-enhanced T1W (ceT1W) and T2-FLAIR MRI images.Approach.The proposed framework included two generators, two discriminators, and two feature extractor networks. A 3-fold cross-validation was used to train and fine-tune the hyperparameters of the proposed model using 230 brain MRI images with tumors, which were then tested on 148 patients'in-vivodatasets. An ablation was performed to evaluate the model's compartments. Our model was compared with Pix2pix and CycleGAN. Six evaluation metrics were reported, including normalized mean squared error (NMSE), structural similarity index (SSIM), multi-scale-SSIM (MS-SSIM), peak signal-to-noise ratio (PSNR), visual information fidelity (VIF), and multi-scale gradient magnitude similarity deviation (MS-GMSD). Artifact reduction and consistency of tumor regions, image contrast, and sharpness were evaluated by three evaluators using Likert scales and compared with ANOVA and Tukey's HSD tests.Main results.On average, our method outperforms comparative models to remove heavy motion artifacts with the lowest NMSE (18.34±5.07%) and MS-GMSD (0.07 ± 0.03) for heavy motion artifact level. Additionally, our method creates motion-free images with the highest SSIM (0.93 ± 0.04), PSNR (30.63 ± 4.96), and VIF (0.45 ± 0.05) values, along with comparable MS-SSIM (0.96 ± 0.31). Similarly, our method outperformed comparative models in removingin-vivomotion artifacts for different distortion levels except for MS- SSIM and VIF, which have comparable performance with CycleGAN. Moreover, our method had a consistent performance for different artifact levels. For the heavy level of motion artifacts, our method got the highest Likert scores of 2.82 ± 0.52, 1.88 ± 0.71, and 1.02 ± 0.14 (p-values≪0.0001) for our method, CycleGAN, and Pix2pix respectively. Similar trends were also found for other motion artifact levels.Significance.Our proposed unsupervised method was demonstrated to reduce motion artifacts from the ceT1W brain images under a multi-parametric framework.
Collapse
Affiliation(s)
- Mojtaba Safari
- Département de physique, de génie physique et d'optique, et Centre de recherche sur le cancer, Université Laval, Québec, Québec, Canada
- Service de physique médicale et radioprotection, Centre Intégré de Cancérologie, CHU de Québec-Université Laval et Centre de recherche du CHU de Québec, Québec, Québec, Canada
| | - Xiaofeng Yang
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322, United States of America
| | - Chih-Wei Chang
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322, United States of America
| | - Richard L J Qiu
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322, United States of America
| | - Ali Fatemi
- Department of Physics, Jackson State University, Jackson, MS, United States of America
- Merit Health Central, Department of Radiation Oncology, Gamma Knife Center, Jackson, MS, United States of America
| | - Louis Archambault
- Département de physique, de génie physique et d'optique, et Centre de recherche sur le cancer, Université Laval, Québec, Québec, Canada
- Service de physique médicale et radioprotection, Centre Intégré de Cancérologie, CHU de Québec-Université Laval et Centre de recherche du CHU de Québec, Québec, Québec, Canada
| |
Collapse
|
15
|
Lee Y, Yoon S, Paek M, Han D, Choi MH, Park SH. Advanced MRI techniques in abdominal imaging. Abdom Radiol (NY) 2024:10.1007/s00261-024-04369-7. [PMID: 38802629 DOI: 10.1007/s00261-024-04369-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2024] [Revised: 04/30/2024] [Accepted: 05/03/2024] [Indexed: 05/29/2024]
Abstract
Magnetic resonance imaging (MRI) is a crucial modality for abdominal imaging evaluation of focal lesions and tissue properties. However, several obstacles, such as prolonged scan times, limitations in patients' breath-hold capacity, and contrast agent-associated artifacts, remain in abdominal MR images. Recent techniques, including parallel imaging, three-dimensional acquisition, compressed sensing, and deep learning, have been developed to reduce the scan time while ensuring acceptable image quality or to achieve higher resolution without extending the scan duration. Quantitative measurements using MRI techniques enable the noninvasive evaluation of specific materials. A comprehensive understanding of these advanced techniques is essential for accurate interpretation of MRI sequences. Herein, we therefore review advanced abdominal MRI techniques.
Collapse
Affiliation(s)
- Yoonhee Lee
- Department of Radiology, Gil Medical Center, Gachon University College of Medicine, 21, Namdong-daero 774beon-gil, Namdong-gu, Incheon, 21565, Republic of Korea
| | - Sungjin Yoon
- Department of Radiology, Gil Medical Center, Gachon University College of Medicine, 21, Namdong-daero 774beon-gil, Namdong-gu, Incheon, 21565, Republic of Korea
| | | | - Dongyeob Han
- Siemens Healthineers Ltd, Seoul, Republic of Korea
| | - Moon Hyung Choi
- Department of Radiology, Catholic University of Korea Eunpyeong St Mary's Hospital, Seoul, Republic of Korea
| | - So Hyun Park
- Department of Radiology, Gil Medical Center, Gachon University College of Medicine, 21, Namdong-daero 774beon-gil, Namdong-gu, Incheon, 21565, Republic of Korea.
| |
Collapse
|
16
|
Oerther B, Engel H, Nedelcu A, Strecker R, Benkert T, Nickel D, Weiland E, Mayrhofer T, Bamberg F, Benndorf M, Weiß J, Wilpert C. Performance of an ultra-fast deep-learning accelerated MRI screening protocol for prostate cancer compared to a standard multiparametric protocol. Eur Radiol 2024:10.1007/s00330-024-10776-7. [PMID: 38780766 DOI: 10.1007/s00330-024-10776-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Revised: 02/23/2024] [Accepted: 03/30/2024] [Indexed: 05/25/2024]
Abstract
OBJECTIVES To establish and evaluate an ultra-fast MRI screening protocol for prostate cancer (PCa) in comparison to the standard multiparametric (mp) protocol, reducing scan time and maintaining adequate diagnostic performance. MATERIALS AND METHODS This prospective single-center study included consecutive biopsy-naïve patients with suspected PCa between December 2022 and March 2023. A PI-RADSv2.1 conform mpMRI protocol was acquired in a 3 T scanner (scan time: 25 min 45 sec). In addition, two deep-learning (DL) accelerated sequences (T2- and diffusion-weighted) were acquired, serving as a screening protocol (scan time: 3 min 28 sec). Two readers evaluated image quality and the probability of PCa regarding PI-RADSv2.1 scores in two sessions. The diagnostic performance of the screening protocol with mpMRI serving as the reference standard was derived. Inter- and intra-reader agreements were evaluated using weighted kappa statistics. RESULTS We included 77 patients with 97 lesions (mean age: 66 years; SD: 7.7). Diagnostic performance of the screening protocol was excellent with a sensitivity and specificity of 100%/100% and 89%/98% (cut-off ≥ PI-RADS 4) for reader 1 (R1) and reader 2 (R2), respectively. Mean image quality was 3.96 (R1) and 4.35 (R2) for the standard protocol vs. 4.74 and 4.57 for the screening protocol (p < 0.05). Inter-reader agreement was moderate (κ: 0.55) for the screening protocol and substantial (κ: 0.61) for the multiparametric protocol. CONCLUSION The ultra-fast screening protocol showed similar diagnostic performance and better imaging quality compared to the mpMRI in under 15% of scan time, improving efficacy and enabling the implementation of screening protocols in clinical routine. CLINICAL RELEVANCE STATEMENT The ultra-fast protocol enables examinations without contrast administration, drastically reducing scan time to 3.5 min with similar diagnostic performance and better imaging quality. This facilitates patient-friendly, efficient examinations and addresses the conflict of increasing demand for examinations at currently exhausted capacities. KEY POINTS Time-consuming MRI protocols are in conflict with an expected increase in examinations required for prostate cancer screening. An ultra-fast MRI protocol shows similar performance and better image quality compared to the standard protocol. Deep-learning acceleration facilitates efficient and patient-friendly examinations, thus improving prostate cancer screening capacity.
Collapse
Affiliation(s)
- B Oerther
- Department of Radiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg im Breisgau, Germany.
| | - H Engel
- Department of Radiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg im Breisgau, Germany
| | - A Nedelcu
- Department of Radiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg im Breisgau, Germany
| | - R Strecker
- MR Application Predevelopment, Siemens Healthineers GmbH, Erlangen, Germany
- EMEA Scientific Partnerships, Siemens Healthineers GmbH, Erlangen, Germany
| | - T Benkert
- MR Application Predevelopment, Siemens Healthineers GmbH, Erlangen, Germany
| | - D Nickel
- MR Application Predevelopment, Siemens Healthineers GmbH, Erlangen, Germany
| | - E Weiland
- MR Application Predevelopment, Siemens Healthineers GmbH, Erlangen, Germany
| | - T Mayrhofer
- School of Business Studies, Stralsund University of Applied Sciences, Stralsund, Germany
- Cardiovascular Imaging Research Center, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| | - F Bamberg
- Department of Radiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg im Breisgau, Germany
| | - M Benndorf
- Department of Radiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg im Breisgau, Germany
| | - J Weiß
- Department of Radiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg im Breisgau, Germany
| | - C Wilpert
- Department of Radiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg im Breisgau, Germany
| |
Collapse
|
17
|
Yao H, Jia B, Pan X, Sun J. Validation and Feasibility of Ultrafast Cervical Spine MRI Using a Deep Learning-Assisted 3D Iterative Image Enhancement System. J Multidiscip Healthc 2024; 17:2499-2509. [PMID: 38799011 PMCID: PMC11128255 DOI: 10.2147/jmdh.s465002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2024] [Accepted: 05/13/2024] [Indexed: 05/29/2024] Open
Abstract
Purpose This study aimed to evaluate the feasibility of ultrafast (2 min) cervical spine MRI protocol using a deep learning-assisted 3D iterative image enhancement (DL-3DIIE) system, compared to a conventional MRI protocol (6 min 14s). Patients and Methods Fifty-one patients were recruited and underwent cervical spine MRI using conventional and ultrafast protocols. A DL-3DIIE system was applied to the ultrafast protocol to compensate for the spatial resolution and signal-to-noise ratio (SNR) of images. Two radiologists independently assessed and graded the quality of images from the dimensions of artifacts, boundary sharpness, visibility of lesions and overall image quality. We recorded the presence or absence of different pathologies. Moreover, we examined the interchangeability of the two protocols by computing the 95% confidence interval of the individual equivalence index, and also evaluated the inter-protocol intra-observer agreement using Cohen's weighted kappa. Results Ultrafast-DL-3DIIE images were significantly better than conventional ones for artifacts and equivalent for other qualitative features. The number of cases with different kinds of pathologies was indistinguishable based on the MR images from ultrafast-DL-3DIIE and conventional protocols. With the exception of disc degeneration, the 95% confidence interval for the individual equivalence index across all variables did not surpass 5%, suggesting that the two protocols are interchangeable. The kappa values of these evaluations by the two radiologists ranged from 0.65 to 0.88, indicating good-to-excellent agreement. Conclusion The DL-3DIIE system enables 67% spine MRI scan time reduction while obtaining at least equivalent image quality and diagnostic results compared to the conventional protocol, suggesting its potential for clinical utility.
Collapse
Affiliation(s)
- Hui Yao
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, 610041, People’s Republic of China
| | - Bangsheng Jia
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, 610041, People’s Republic of China
| | - Xuelin Pan
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, 610041, People’s Republic of China
| | - Jiayu Sun
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, 610041, People’s Republic of China
| |
Collapse
|
18
|
Malik MA, Weber AM, Lang D, Vanderwal T, Zwicker JG. Changes in cortical grey matter volume with Cognitive Orientation to daily Occupational Performance intervention in children with developmental coordination disorder. Front Hum Neurosci 2024; 18:1316117. [PMID: 38841123 PMCID: PMC11150831 DOI: 10.3389/fnhum.2024.1316117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2023] [Accepted: 05/03/2024] [Indexed: 06/07/2024] Open
Abstract
Introduction Cognitive Orientation to daily Occupational Performance (CO-OP) is a cognitive-based, task-specific intervention recommended for children with developmental coordination disorder (DCD). We recently showed structural and functional brain changes after CO-OP, including increased cerebellar grey matter. This study aimed to determine whether CO-OP intervention induced changes in cortical grey matter volume in children with DCD, and if these changes were associated with improvements in motor performance and movement quality. Methods This study is part of a randomized waitlist-control trial (ClinicalTrials.gov ID: NCT02597751). Children with DCD (N = 78) were randomized to either a treatment or waitlist group and underwent three MRIs over 6 months. The treatment group received intervention (once weekly for 10 weeks) between the first and second scan; the waitlist group received intervention between the second and third scan. Cortical grey matter volume was measured using voxel-based morphometry (VBM). Behavioral outcome measures included the Performance Quality Rating Scale (PQRS) and Bruininks-Oseretsky Test of Motor Proficiency-2 (BOT-2). Of the 78 children, 58 were excluded (mostly due to insufficient data quality), leaving a final N = 20 for analyses. Due to the small sample size, we combined both groups to examine treatment effects. Cortical grey matter volume differences were assessed using a repeated measures ANOVA, controlling for total intracranial volume. Regression analyses examined the relationship of grey matter volume changes to BOT-2 (motor performance) and PQRS (movement quality). Results After CO-OP, children had significantly decreased grey matter in the right superior frontal gyrus and middle/posterior cingulate gyri. We found no significant associations of grey matter volume changes with PQRS or BOT-2 scores. Conclusion Decreased cortical grey matter volume generally reflects greater brain maturity. Decreases in grey matter volume after CO-OP intervention were in regions associated with self-regulation and motor control, consistent with our other studies. Decreased grey matter volume may be due to focal increases in synaptic pruning, perhaps as a result of strengthening networks in the brain via the repeated learning and actions in therapy. Findings from this study add to the growing body of literature demonstrating positive neuroplastic changes in the brain after CO-OP intervention.
Collapse
Affiliation(s)
- Myrah Anum Malik
- Graduate Programs in Rehabilitation Science, University of British Columbia, Vancouver, BC, Canada
| | - Alexander Mark Weber
- Brain, Behaviour, and Development Theme, BC Children’s Hospital Research Institute, Vancouver, BC, Canada
- Department of Pediatrics, University of British Columbia, Vancouver, BC, Canada
| | - Donna Lang
- Brain, Behaviour, and Development Theme, BC Children’s Hospital Research Institute, Vancouver, BC, Canada
- Department of Radiology, University of British Columbia, Vancouver, BC, Canada
| | - Tamara Vanderwal
- Brain, Behaviour, and Development Theme, BC Children’s Hospital Research Institute, Vancouver, BC, Canada
- Department of Psychiatry, University of British Columbia, Vancouver, BC, Canada
| | - Jill G. Zwicker
- Brain, Behaviour, and Development Theme, BC Children’s Hospital Research Institute, Vancouver, BC, Canada
- Department of Pediatrics, University of British Columbia, Vancouver, BC, Canada
- Department of Occupational Science and Occupational Therapy, University of British Columbia, Vancouver, BC, Canada
| |
Collapse
|
19
|
Rizzuti G, Schakel T, Huttinga NRF, Dankbaar JW, van Leeuwen T, Sbrizzi A. Towards retrospective motion correction and reconstruction for clinical 3D brain MRI protocols with a reference contrast. MAGMA (NEW YORK, N.Y.) 2024:10.1007/s10334-024-01161-y. [PMID: 38758490 DOI: 10.1007/s10334-024-01161-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/10/2024] [Revised: 04/19/2024] [Accepted: 04/22/2024] [Indexed: 05/18/2024]
Abstract
OBJECT In a typical MR session, several contrasts are acquired. Due to the sequential nature of the data acquisition process, the patient may experience some discomfort at some point during the session, and start moving. Hence, it is quite common to have MR sessions where some contrasts are well-resolved, while other contrasts exhibit motion artifacts. Instead of repeating the scans that are corrupted by motion, we introduce a reference-guided retrospective motion correction scheme that takes advantage of the motion-free scans, based on a generalized rigid registration routine. MATERIALS AND METHODS We focus on various existing clinical 3D brain protocols at 1.5 Tesla MRI based on Cartesian sampling. Controlled experiments with three healthy volunteers and three levels of motion are performed. RESULTS Radiological inspection confirms that the proposed method consistently ameliorates the corrupted scans. Furthermore, for the set of specific motion tests performed in this study, the quality indexes based on PSNR and SSIM shows only a modest decrease in correction quality as a function of motion complexity. DISCUSSION While the results on controlled experiments are positive, future applications to patient data will ultimately clarify whether the proposed correction scheme satisfies the radiological requirements.
Collapse
Affiliation(s)
- Gabrio Rizzuti
- Utrecht University, Heidelberglaan 8, 3584 CS, Utrecht, The Netherlands
- Universitair Medisch Centrum Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| | - Tim Schakel
- Universitair Medisch Centrum Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| | - Niek R F Huttinga
- Universitair Medisch Centrum Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| | - Jan Willem Dankbaar
- Universitair Medisch Centrum Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| | - Tristan van Leeuwen
- Utrecht University, Heidelberglaan 8, 3584 CS, Utrecht, The Netherlands
- Centrum Wiskunde & Informatica, Science Park Amsterdam 123, 1098 XG, Amsterdam, The Netherlands
| | - Alessandro Sbrizzi
- Universitair Medisch Centrum Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands.
| |
Collapse
|
20
|
Dunn A, Wagner S, Sussman D. Scoping review of magnetic resonance motion imaging phantoms. MAGMA (NEW YORK, N.Y.) 2024:10.1007/s10334-024-01164-9. [PMID: 38739218 DOI: 10.1007/s10334-024-01164-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/31/2023] [Revised: 03/28/2024] [Accepted: 04/29/2024] [Indexed: 05/14/2024]
Abstract
To review and analyze the currently available MRI motion phantoms. Publications were collected from the Toronto Metropolitan University Library, PubMed, and IEEE Xplore. Phantoms were categorized based on the motions they generated: linear/cartesian, cardiac-dilative, lung-dilative, rotational, deformation or rolling. Metrics were extracted from each publication to assess the motion mechanisms, construction methods, as well as phantom validation. A total of 60 publications were reviewed, identifying 48 unique motion phantoms. Translational movement was the most common movement (used in 38% of phantoms), followed by cardiac-dilative (27%) movement and rotational movement (23%). The average degrees of freedom for all phantoms were determined to be 1.42. Motion phantom publications lack quantification of their impact on signal-to-noise ratio through standardized testing. At present, there is a lack of phantoms that are designed for multi-role as many currently have few degrees of freedom.
Collapse
Affiliation(s)
- Alexander Dunn
- Department of Electrical, Computer, and Biomedical Engineering, Toronto Metropolitan University, Toronto, Canada
- Institute for Biomedical Engineering, Science and Technology (iBEST) at Toronto Metropolitan University and St. Michael's Hospital, Toronto, Canada
| | - Sophie Wagner
- Department of Electrical, Computer, and Biomedical Engineering, Toronto Metropolitan University, Toronto, Canada
- Institute for Biomedical Engineering, Science and Technology (iBEST) at Toronto Metropolitan University and St. Michael's Hospital, Toronto, Canada
| | - Dafna Sussman
- Department of Electrical, Computer, and Biomedical Engineering, Toronto Metropolitan University, Toronto, Canada.
- Institute for Biomedical Engineering, Science and Technology (iBEST) at Toronto Metropolitan University and St. Michael's Hospital, Toronto, Canada.
- Department of Obstetrics and Gynecology, University of Toronto, Toronto, Canada.
| |
Collapse
|
21
|
Ming Z, Pogosyan A, Christodoulou AG, Finn JP, Ruan D, Nguyen KL. Dynamic Regularized Adaptive Cluster Optimization (DRACO) for Quantitative Cardiac Cine MRI in Complex Arrhythmias. J Magn Reson Imaging 2024. [PMID: 38708951 DOI: 10.1002/jmri.29425] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2023] [Revised: 04/17/2024] [Accepted: 04/18/2024] [Indexed: 05/07/2024] Open
Abstract
BACKGROUND Irregular cardiac motion can render conventional segmented cine MRI nondiagnostic. Clustering has been proposed for cardiac motion binning and may be optimized for complex arrhythmias. PURPOSE To develop an adaptive cluster optimization method for irregular cardiac motion, and to generate the corresponding time-resolved cine images. STUDY TYPE Prospective. SUBJECTS Thirteen with atrial fibrillation, four with premature ventricular contractions, and one patient in sinus rhythm. FIELD STRENGTH/SEQUENCE Free-running balanced steady state free precession (bSSFP) with sorted golden-step, reference real-time sequence. ASSESSMENT Each subject underwent both the sorted golden-step bSSFP and the reference Cartesian real-time imaging. Golden-step bSSFP images were reconstructed using the dynamic regularized adaptive cluster optimization (DRACO) method and k-means clustering. Image quality (4-point Likert scale), signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), edge sharpness, and ventricular function were assessed. STATISTICAL TESTS Paired t-tests, Friedman test, regression analysis, Fleiss' Kappa, Bland-Altman analysis. Significance level P < 0.05. RESULTS The DRACO method had the highest percent of images with scores ≥3 (96% for diastolic frame, 93% for systolic frame, and 93% for multiphase cine) and the percentages were significantly higher compared with both the k-means and real-time methods. Image quality scores, SNR, and CNR were significantly different between DRACO vs. k-means and between DRACO vs. real-time. Cardiac function analysis showed no significant differences between DRACO vs. the reference real-time. CONCLUSION DRACO with time-resolved reconstruction generated high quality images and has early promise for quantitative cine cardiac MRI in patients with complex arrhythmias including atrial fibrillation. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY Stage 2.
Collapse
Affiliation(s)
- Zhengyang Ming
- Physics and Biology in Medicine Graduate Program, University of California, Los Angeles, California, USA
- Department of Radiological Sciences, David Geffen School of Medicine at UCLA, Los Angeles, California, USA
| | - Arutyun Pogosyan
- Division of Cardiology, David Geffen School of Medicine at UCLA and VA Greater Los Angeles Healthcare System, Los Angeles, California, USA
| | - Anthony G Christodoulou
- Department of Radiological Sciences, David Geffen School of Medicine at UCLA, Los Angeles, California, USA
- Department of Bioengineering, University of California, Los Angeles, California, USA
| | - J Paul Finn
- Physics and Biology in Medicine Graduate Program, University of California, Los Angeles, California, USA
- Department of Radiological Sciences, David Geffen School of Medicine at UCLA, Los Angeles, California, USA
| | - Dan Ruan
- Physics and Biology in Medicine Graduate Program, University of California, Los Angeles, California, USA
- Department of Bioengineering, University of California, Los Angeles, California, USA
- Department of Radiation Oncology, David Geffen School of Medicine at UCLA, California, USA
| | - Kim-Lien Nguyen
- Physics and Biology in Medicine Graduate Program, University of California, Los Angeles, California, USA
- Department of Radiological Sciences, David Geffen School of Medicine at UCLA, Los Angeles, California, USA
- Division of Cardiology, David Geffen School of Medicine at UCLA and VA Greater Los Angeles Healthcare System, Los Angeles, California, USA
- Department of Bioengineering, University of California, Los Angeles, California, USA
| |
Collapse
|
22
|
Hossain MB, Shinde RK, Imtiaz SM, Hossain FMF, Jeon SH, Kwon KC, Kim N. Swin Transformer and the Unet Architecture to Correct Motion Artifacts in Magnetic Resonance Image Reconstruction. Int J Biomed Imaging 2024; 2024:8972980. [PMID: 38725808 PMCID: PMC11081754 DOI: 10.1155/2024/8972980] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2023] [Revised: 04/08/2024] [Accepted: 04/23/2024] [Indexed: 05/12/2024] Open
Abstract
We present a deep learning-based method that corrects motion artifacts and thus accelerates data acquisition and reconstruction of magnetic resonance images. The novel model, the Motion Artifact Correction by Swin Network (MACS-Net), uses a Swin transformer layer as the fundamental block and the Unet architecture as the neural network backbone. We employ a hierarchical transformer with shifted windows to extract multiscale contextual features during encoding. A new dual upsampling technique is employed to enhance the spatial resolutions of feature maps in the Swin transformer-based decoder layer. A raw magnetic resonance imaging dataset is used for network training and testing; the data contain various motion artifacts with ground truth images of the same subjects. The results were compared to six state-of-the-art MRI image motion correction methods using two types of motions. When motions were brief (within 5 s), the method reduced the average normalized root mean square error (NRMSE) from 45.25% to 17.51%, increased the mean structural similarity index measure (SSIM) from 79.43% to 91.72%, and increased the peak signal-to-noise ratio (PSNR) from 18.24 to 26.57 dB. Similarly, when motions were extended from 5 to 10 s, our approach decreased the average NRMSE from 60.30% to 21.04%, improved the mean SSIM from 33.86% to 90.33%, and increased the PSNR from 15.64 to 24.99 dB. The anatomical structures of the corrected images and the motion-free brain data were similar.
Collapse
Affiliation(s)
- Md. Biddut Hossain
- Department of Information and Communication Engineering, Chungbuk National University, Cheongju-si 28644, Chungcheongbuk-do, Republic of Korea
| | - Rupali Kiran Shinde
- Department of Information and Communication Engineering, Chungbuk National University, Cheongju-si 28644, Chungcheongbuk-do, Republic of Korea
| | - Shariar Md Imtiaz
- Department of Information and Communication Engineering, Chungbuk National University, Cheongju-si 28644, Chungcheongbuk-do, Republic of Korea
| | - F. M. Fahmid Hossain
- Department of Information and Communication Engineering, Chungbuk National University, Cheongju-si 28644, Chungcheongbuk-do, Republic of Korea
| | - Seok-Hee Jeon
- Department of Electronics Engineering, Incheon National University, 119 Academy-ro, Yeonsu-gu, Incheon 22012, Republic of Korea
| | - Ki-Chul Kwon
- Department of Information and Communication Engineering, Chungbuk National University, Cheongju-si 28644, Chungcheongbuk-do, Republic of Korea
| | - Nam Kim
- Department of Information and Communication Engineering, Chungbuk National University, Cheongju-si 28644, Chungcheongbuk-do, Republic of Korea
| |
Collapse
|
23
|
Beljaards L, Pezzotti N, Rao C, Doneva M, van Osch MJP, Staring M. AI-based motion artifact severity estimation in undersampled MRI allowing for selection of appropriate reconstruction models. Med Phys 2024; 51:3555-3565. [PMID: 38167996 DOI: 10.1002/mp.16918] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2023] [Revised: 11/30/2023] [Accepted: 12/04/2023] [Indexed: 01/05/2024] Open
Abstract
BACKGROUND Magnetic Resonance acquisition is a time consuming process, making it susceptible to patient motion during scanning. Even motion in the order of a millimeter can introduce severe blurring and ghosting artifacts, potentially necessitating re-acquisition. Magnetic Resonance Imaging (MRI) can be accelerated by acquiring only a fraction of k-space, combined with advanced reconstruction techniques leveraging coil sensitivity profiles and prior knowledge. Artificial intelligence (AI)-based reconstruction techniques have recently been popularized, but generally assume an ideal setting without intra-scan motion. PURPOSE To retrospectively detect and quantify the severity of motion artifacts in undersampled MRI data. This may prove valuable as a safety mechanism for AI-based approaches, provide useful information to the reconstruction method, or prompt for re-acquisition while the patient is still in the scanner. METHODS We developed a deep learning approach that detects and quantifies motion artifacts in undersampled brain MRI. We demonstrate that synthetically motion-corrupted data can be leveraged to train the convolutional neural network (CNN)-based motion artifact estimator, generalizing well to real-world data. Additionally, we leverage the motion artifact estimator by using it as a selector for a motion-robust reconstruction model in case a considerable amount of motion was detected, and a high data consistency model otherwise. RESULTS Training and validation were performed on 4387 and 1304 synthetically motion-corrupted images and their uncorrupted counterparts, respectively. Testing was performed on undersampled in vivo motion-corrupted data from 28 volunteers, where our model distinguished head motion from motion-free scans with 91% and 96% accuracy when trained on synthetic and on real data, respectively. It predicted a manually defined quality label ('Good', 'Medium' or 'Bad' quality) correctly in 76% and 85% of the time when trained on synthetic and real data, respectively. When used as a selector it selected the appropriate reconstruction network 93% of the time, achieving near optimal SSIM values. CONCLUSIONS The proposed method quantified motion artifact severity in undersampled MRI data with high accuracy, enabling real-time motion artifact detection that can help improve the safety and quality of AI-based reconstructions.
Collapse
Affiliation(s)
- Laurens Beljaards
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Nicola Pezzotti
- Cardiologs, Philips, Paris, France
- Faculty of Computer Science, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Chinmay Rao
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | | | | | - Marius Staring
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| |
Collapse
|
24
|
Xia S, Gowda P, Silva FD, Guirguis M, Ravi V, Xi Y, Chhabra A. Comparison between ZOOMit DWI and conventional DWI in the assessment of foot and ankle infection: a prospective study. Eur Radiol 2024; 34:3483-3492. [PMID: 37848770 DOI: 10.1007/s00330-023-10315-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Revised: 08/16/2023] [Accepted: 08/23/2023] [Indexed: 10/19/2023]
Abstract
OBJECTIVE The study aimed to compare ZOOMit diffusion-weighted imaging (DWI) MRI with conventional DWI MRI for visualizing small bones in the foot, soft tissue abscesses, and osteomyelitis. MATERIALS AND METHODS The cohort consisted of a consecutive series of patients with potential foot and ankle infections referred for MR imaging. Patients were imaged using both conventional and ZOOMit DWI in the same setting. Blinded reads were then conducted in separate settings and independent of known clinical diagnosis by two expert radiologists. The results from the reads were compared statistically using paired t-tests and with biopsy specimen analysis, both anatomopathological and microbiological. RESULTS There was improvement in fat suppression using ZOOMit sequence compared to conventional DWI (p = .001) with no significant difference in motion artifacts (p = .278). ZOOMit had a higher rate of concordance with pathology findings for osteomyelitis (72%, 31/43 cases) compared with conventional DWI (60%, 26/43 cases). ZOOMit also identified 46 additional small bones of the foot and ankle (405/596, 68.0%) than conventional DWI (359/596, 60.2%). Conventional DWI however exhibited a more negative contrast-to-noise ratio (CNR) than ZOOMit (p = 0.001). CONCLUSION ZOOMit DWI improves distal extremity proton diffusion assessment and helps visualize more bones in the foot, with less image distortion and improved fat saturation at the expense of reduced CNR. This makes it a viable option for assessing lower extremity infections. CLINICAL RELEVANCE STATEMENT This study highlights the novel utilization of ZOOMit diffusion-weighted imaging (DWI) for the assessment of lower extremity lesions compared to conventional DWI. KEY POINTS • Distal extremity diffusion-weighted imaging (DWI) is often limited. • ZOOMit DWI displayed improved fat suppression with less motion artifacts and better visualization of the lower extremity bones than conventional DWI. • ZOOMit shows decreased contrast-to-noise ratio than conventional DWI.
Collapse
Affiliation(s)
| | | | | | | | | | - Yin Xi
- UT Southwestern, Dallas, TX, USA
| | - Avneesh Chhabra
- UT Southwestern, Dallas, TX, USA.
- Radiology & Orthopedic Surgery, UT Southwestern, Dallas, TX, 75390-9178, USA.
- Johns Hopkins University, Baltimore, MD, USA.
- University of Dallas, Richardson, TX, USA.
- Walton Centre for Neuroscience, Liverpool, UK.
| |
Collapse
|
25
|
Motyka S, Weiser P, Bachrata B, Hingerl L, Strasser B, Hangel G, Niess E, Niess F, Zaitsev M, Robinson SD, Langs G, Trattnig S, Bogner W. Predicting dynamic, motion-related changes in B 0 field in the brain at a 7T MRI using a subject-specific fine-trained U-net. Magn Reson Med 2024; 91:2044-2056. [PMID: 38193276 DOI: 10.1002/mrm.29980] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2023] [Revised: 11/28/2023] [Accepted: 11/30/2023] [Indexed: 01/10/2024]
Abstract
PURPOSE Subject movement during the MR examination is inevitable and causes not only image artifacts but also deteriorates the homogeneity of the main magnetic field (B0 ), which is a prerequisite for high quality data. Thus, characterization of changes to B0 , for example induced by patient movement, is important for MR applications that are prone to B0 inhomogeneities. METHODS We propose a deep learning based method to predict such changes within the brain from the change of the head position to facilitate retrospective or even real-time correction. A 3D U-net was trained on in vivo gradient-echo brain 7T MRI data. The input consisted of B0 maps and anatomical images at an initial position, and anatomical images at a different head position (obtained by applying a rigid-body transformation on the initial anatomical image). The output consisted of B0 maps at the new head positions. We further fine-trained the network weights to each subject by measuring a limited number of head positions of the given subject, and trained the U-net with these data. RESULTS Our approach was compared to established dynamic B0 field mapping via interleaved navigators, which suffer from limited spatial resolution and the need for undesirable sequence modifications. Qualitative and quantitative comparison showed similar performance between an interleaved navigator-equivalent method and proposed method. CONCLUSION It is feasible to predict B0 maps from rigid subject movement and, when combined with external tracking hardware, this information could be used to improve the quality of MR acquisitions without the use of navigators.
Collapse
Affiliation(s)
- Stanislav Motyka
- High Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
- Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna, Austria
| | - Paul Weiser
- Computational Imaging Research Lab, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Beata Bachrata
- Department of Medical Engineering, Carinthia University of Applied Sciences, Klagenfurt, Austria
| | - Lukas Hingerl
- High Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Bernhard Strasser
- High Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Gilbert Hangel
- High Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
- Department of Neurosurgery, Medical University of Vienna, Vienna, Austria
| | - Eva Niess
- High Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
- Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna, Austria
| | - Fabian Niess
- High Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Maxim Zaitsev
- Department of Radiology - Medical Physics, University of Freiburg, Freiburg, Germany
- Faculty of Medicine, University of Freiburg - Medical Centre, Freiburg, Germany
| | - Simon Daniel Robinson
- High Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Georg Langs
- Computational Imaging Research Lab, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Siegfried Trattnig
- High Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Wolfgang Bogner
- High Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
- Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna, Austria
| |
Collapse
|
26
|
Brackenier Y, Wang N, Liao C, Cao X, Schauman S, Yurt M, Cordero-Grande L, Malik SJ, Kerr A, Hajnal JV, Setsompop K. Rapid and accurate navigators for motion and B 0 tracking using QUEEN: Quantitatively enhanced parameter estimation from navigators. Magn Reson Med 2024; 91:2028-2043. [PMID: 38173304 DOI: 10.1002/mrm.29976] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2023] [Revised: 11/28/2023] [Accepted: 11/29/2023] [Indexed: 01/05/2024]
Abstract
PURPOSE To develop a framework that jointly estimates rigid motion and polarizing magnetic field (B0 ) perturbations (δ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ ) for brain MRI using a single navigator of a few milliseconds in duration, and to additionally allow for navigator acquisition at arbitrary timings within any type of sequence to obtain high-temporal resolution estimates. THEORY AND METHODS Methods exist that match navigator data to a low-resolution single-contrast image (scout) to estimate either motion orδ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ . In this work, called QUEEN (QUantitatively Enhanced parameter Estimation from Navigators), we propose combined motion andδ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ estimation from a fast, tailored trajectory with arbitrary-contrast navigator data. To this end, the concept of a quantitative scout (Q-Scout) acquisition is proposed from which contrast-matched scout data is predicted for each navigator. Finally, navigator trajectories, contrast-matched scout, andδ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ are integrated into a motion-informed parallel-imaging framework. RESULTS Simulations and in vivo experiments show the need to modelδ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ to obtain accurate motion parameters estimated in the presence of strongδ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ . Simulations confirm that tailored navigator trajectories are needed to robustly estimate both motion andδ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ . Furthermore, experiments show that a contrast-matched scout is needed for parameter estimation from multicontrast navigator data. A retrospective, in vivo reconstruction experiment shows improved image quality when using the proposed Q-Scout and QUEEN estimation. CONCLUSIONS We developed a framework to jointly estimate rigid motion parameters andδ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ from navigators. Combing a contrast-matched scout with the proposed trajectory allows for navigator deployment in almost any sequence and/or timing, which allows for higher temporal-resolution motion andδ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ estimates.
Collapse
Affiliation(s)
| | - Nan Wang
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Congyu Liao
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Xiaozhi Cao
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Sophie Schauman
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Mahmut Yurt
- Department of Radiology, Stanford University, Stanford, California, USA
- Department of Electrical Engineering, Stanford University, Stanford, California, USA
| | - Lucilio Cordero-Grande
- Biomedical Image Technologies, ETSI Telecomunicación, Universidad Politécnica de Madrid and CIBER-BNN, Madrid, Spain
| | - Shaihan J Malik
- Biomedical Engineering Department, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- Center for the Developing Brain, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| | - Adam Kerr
- Department of Electrical Engineering, Stanford University, Stanford, California, USA
- Cognitive and Neurobiological Imaging, Stanford University, Stanford, California, USA
| | - Joseph V Hajnal
- Biomedical Engineering Department, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- Center for the Developing Brain, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| | - Kawin Setsompop
- Department of Radiology, Stanford University, Stanford, California, USA
- Department of Electrical Engineering, Stanford University, Stanford, California, USA
| |
Collapse
|
27
|
Olsson H, Millward JM, Starke L, Gladytz T, Klein T, Fehr J, Lai WC, Lippert C, Niendorf T, Waiczies S. Simulating rigid head motion artifacts on brain magnitude MRI data-Outcome on image quality and segmentation of the cerebral cortex. PLoS One 2024; 19:e0301132. [PMID: 38626138 PMCID: PMC11020361 DOI: 10.1371/journal.pone.0301132] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Accepted: 03/11/2024] [Indexed: 04/18/2024] Open
Abstract
Magnetic Resonance Imaging (MRI) datasets from epidemiological studies often show a lower prevalence of motion artifacts than what is encountered in clinical practice. These artifacts can be unevenly distributed between subject groups and studies which introduces a bias that needs addressing when augmenting data for machine learning purposes. Since unreconstructed multi-channel k-space data is typically not available for population-based MRI datasets, motion simulations must be performed using signal magnitude data. There is thus a need to systematically evaluate how realistic such magnitude-based simulations are. We performed magnitude-based motion simulations on a dataset (MR-ART) from 148 subjects in which real motion-corrupted reference data was also available. The similarity of real and simulated motion was assessed by using image quality metrics (IQMs) including Coefficient of Joint Variation (CJV), Signal-to-Noise-Ratio (SNR), and Contrast-to-Noise-Ratio (CNR). An additional comparison was made by investigating the decrease in the Dice-Sørensen Coefficient (DSC) of automated segmentations with increasing motion severity. Segmentation of the cerebral cortex was performed with 6 freely available tools: FreeSurfer, BrainSuite, ANTs, SAMSEG, FastSurfer, and SynthSeg+. To better mimic the real subject motion, the original motion simulation within an existing data augmentation framework (TorchIO), was modified. This allowed a non-random motion paradigm and phase encoding direction. The mean difference in CJV/SNR/CNR between the real motion-corrupted images and our modified simulations (0.004±0.054/-0.7±1.8/-0.09±0.55) was lower than that of the original simulations (0.015±0.061/0.2±2.0/-0.29±0.62). Further, the mean difference in the DSC between the real motion-corrupted images was lower for our modified simulations (0.03±0.06) compared to the original simulations (-0.15±0.09). SynthSeg+ showed the highest robustness towards all forms of motion, real and simulated. In conclusion, reasonably realistic synthetic motion artifacts can be induced on a large-scale when only magnitude MR images are available to obtain unbiased data sets for the training of machine learning based models.
Collapse
Affiliation(s)
- Hampus Olsson
- Max-Delbrück-Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin Ultrahigh Field Facility (B.U.F.F.), Berlin, Germany
| | - Jason Michael Millward
- Max-Delbrück-Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin Ultrahigh Field Facility (B.U.F.F.), Berlin, Germany
- Experimental and Clinical Research Center, A Joint Cooperation Between the Charité Medical Faculty and the Max-Delbrück-Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin, Germany
| | - Ludger Starke
- Max-Delbrück-Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin Ultrahigh Field Facility (B.U.F.F.), Berlin, Germany
| | - Thomas Gladytz
- Max-Delbrück-Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin Ultrahigh Field Facility (B.U.F.F.), Berlin, Germany
| | - Tobias Klein
- Max-Delbrück-Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin Ultrahigh Field Facility (B.U.F.F.), Berlin, Germany
| | - Jana Fehr
- Digital Health & Machine Learning Group, Hasso Plattner Institute for Digital Engineering, Potsdam, Germany
| | - Wei-Chang Lai
- Digital Health & Machine Learning Group, Hasso Plattner Institute for Digital Engineering, Potsdam, Germany
| | - Christoph Lippert
- Digital Health & Machine Learning Group, Hasso Plattner Institute for Digital Engineering, Potsdam, Germany
- Hasso Plattner Institute for Digital Health at Mount Sinai, Icahn School of Medicine at Mount Sinai, New York, NY, United States of America
| | - Thoralf Niendorf
- Max-Delbrück-Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin Ultrahigh Field Facility (B.U.F.F.), Berlin, Germany
- Experimental and Clinical Research Center, A Joint Cooperation Between the Charité Medical Faculty and the Max-Delbrück-Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin, Germany
| | - Sonia Waiczies
- Max-Delbrück-Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin Ultrahigh Field Facility (B.U.F.F.), Berlin, Germany
- Experimental and Clinical Research Center, A Joint Cooperation Between the Charité Medical Faculty and the Max-Delbrück-Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin, Germany
| |
Collapse
|
28
|
Safari M, Yang X, Fatemi A, Archambault L. MRI motion artifact reduction using a conditional diffusion probabilistic model (MAR-CDPM). Med Phys 2024; 51:2598-2610. [PMID: 38009583 DOI: 10.1002/mp.16844] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2023] [Revised: 11/09/2023] [Accepted: 11/09/2023] [Indexed: 11/29/2023] Open
Abstract
BACKGROUND High-resolution magnetic resonance imaging (MRI) with excellent soft-tissue contrast is a valuable tool utilized for diagnosis and prognosis. However, MRI sequences with long acquisition time are susceptible to motion artifacts, which can adversely affect the accuracy of post-processing algorithms. PURPOSE This study proposes a novel retrospective motion correction method named "motion artifact reduction using conditional diffusion probabilistic model" (MAR-CDPM). The MAR-CDPM aimed to remove motion artifacts from multicenter three-dimensional contrast-enhanced T1 magnetization-prepared rapid acquisition gradient echo (3D ceT1 MPRAGE) brain dataset with different brain tumor types. MATERIALS AND METHODS This study employed two publicly accessible MRI datasets: one containing 3D ceT1 MPRAGE and 2D T2-fluid attenuated inversion recovery (FLAIR) images from 230 patients with diverse brain tumors, and the other comprising 3D T1-weighted (T1W) MRI images of 148 healthy volunteers, which included real motion artifacts. The former was used to train and evaluate the model using the in silico data, and the latter was used to evaluate the model performance to remove real motion artifacts. A motion simulation was performed in k-space domain to generate an in silico dataset with minor, moderate, and heavy distortion levels. The diffusion process of the MAR-CDPM was then implemented in k-space to convert structure data into Gaussian noise by gradually increasing motion artifact levels. A conditional network with a Unet backbone was trained to reverse the diffusion process to convert the distorted images to structured data. The MAR-CDPM was trained in two scenarios: one conditioning on the time step t $t$ of the diffusion process, and the other conditioning on both t $t$ and T2-FLAIR images. The MAR-CDPM was quantitatively and qualitatively compared with supervised Unet, Unet conditioned on T2-FLAIR, CycleGAN, Pix2pix, and Pix2pix conditioned on T2-FLAIR models. To quantify the spatial distortions and the level of remaining motion artifacts after applying the models, quantitative metrics were reported including normalized mean squared error (NMSE), structural similarity index (SSIM), multiscale structural similarity index (MS-SSIM), peak signal-to-noise ratio (PSNR), visual information fidelity (VIF), and multiscale gradient magnitude similarity deviation (MS-GMSD). Tukey's Honestly Significant Difference multiple comparison test was employed to quantify the difference between the models where p-value < 0.05 $ < 0.05$ was considered statistically significant. RESULTS Qualitatively, MAR-CDPM outperformed these methods in preserving soft-tissue contrast and different brain regions. It also successfully preserved tumor boundaries for heavy motion artifacts, like the supervised method. Our MAR-CDPM recovered motion-free in silico images with the highest PSNR and VIF for all distortion levels where the differences were statistically significant (p-values< 0.05 $< 0.05$ ). In addition, our method conditioned on t and T2-FLAIR outperformed (p-values< 0.05 $< 0.05$ ) other methods to remove motion artifacts from the in silico dataset in terms of NMSE, MS-SSIM, SSIM, and MS-GMSD. Moreover, our method conditioned on only t outperformed generative models (p-values< 0.05 $< 0.05$ ) and had comparable performances compared with the supervised model (p-values> 0.05 $> 0.05$ ) to remove real motion artifacts. CONCLUSIONS The MAR-CDPM could successfully remove motion artifacts from 3D ceT1 MPRAGE. It is particularly beneficial for elderly who may experience involuntary movements during high-resolution MRI imaging with long acquisition times.
Collapse
Affiliation(s)
- Mojtaba Safari
- Département de physique, de génie physique et d'optique, et Centre de recherche sur le cancer, Université Laval, Quebec, Quebec, Canada
- Service de physique médicale et radioprotection, Centre Intégré de Cancérologie, CHU de Québec-Université Laval et Centre de recherche du CHU de Québec, Quebec, Quebec, Canada
| | - Xiaofeng Yang
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA
| | - Ali Fatemi
- Department of Physics, Jackson State University, Jackson, Mississippi, USA
- Merit Health Central, Department of Radiation Oncology, Gamma Knife Center, Jackson, Mississippi, USA
| | - Louis Archambault
- Département de physique, de génie physique et d'optique, et Centre de recherche sur le cancer, Université Laval, Quebec, Quebec, Canada
- Service de physique médicale et radioprotection, Centre Intégré de Cancérologie, CHU de Québec-Université Laval et Centre de recherche du CHU de Québec, Quebec, Quebec, Canada
| |
Collapse
|
29
|
Kara D, Koenig K, Lowe M, Nguyen C, Sakaie K. Facilitating diffusion tensor imaging of the brain during continuous gross head motion with first and second order motion compensating diffusion gradients. Magn Reson Med 2024; 91:1556-1566. [PMID: 38073070 PMCID: PMC10872734 DOI: 10.1002/mrm.29924] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Revised: 10/19/2023] [Accepted: 10/24/2023] [Indexed: 01/26/2024]
Abstract
PURPOSE To demonstrate the feasibility of motion compensating diffusion gradient schemes in the acquisition of quality diffusion tensor images (DTI) of the brain during continuous gross head motion. METHODS Five healthy subjects were scanned using a clinical 3 T MRI with and without continuous head motion. For one volunteer, DTI data was acquired using standard (M0) diffusion-weighted (DW) gradients, and first (M1) and second (M2) order gradient schemes that were previously developed for use in cardiac DTI. In four additional volunteers, DTI data was acquired with M0 and M2 gradients. DTI parameters were calculated and compared with established retrospective motion corrections. RESULTS In the absence of motion, DTI parameters calculated from M0, M1, and M2 data were consistent. In the presence of motion, up to 44% of DW images acquired with M0 gradients were corrupted by signal dropout, compared to 0% of the M2 images. In voxelwise comparisons, DTI parameters calculated using motion-M0 data were elevated compared to reference data. Retrospective corrections for extreme motion applied to motion-M0 data did not improve consistency with reference data in cases where motion corrupted >15% of DW images. In contrast, DTI parameters calculated with motion-M2 data were consistent with reference data. CONCLUSION This proof-of-principle study demonstrates that motion compensating diffusion gradients can mitigate artifacts because of continuous motion in DTI of the brain and offers promise for improved DTI accessibility. Further study will be necessary to determine the robustness of the approach in patient populations with high susceptibility to head motion.
Collapse
Affiliation(s)
- Danielle Kara
- Cardiovascular Innovation Research Center, Heart, Vascular, and Thoracic Institute, Cleveland Clinic
| | | | - Mark Lowe
- Imaging Sciences, Imaging Institute, Cleveland Clinic
| | - Christopher Nguyen
- Cardiovascular Innovation Research Center, Heart, Vascular, and Thoracic Institute, Cleveland Clinic
- Imaging Sciences, Imaging Institute, Cleveland Clinic
- Biomedical Engineering, Lerner Research Institute, Cleveland Clinic and Case Western Reserve University
| | - Ken Sakaie
- Imaging Sciences, Imaging Institute, Cleveland Clinic
| |
Collapse
|
30
|
Ganesh VKSV, Kamepalli HK, Sharma DP, Thomas B, Kesavadas C. Multi-contrast echo-planar imaging sequence (Echo-planar imaging mix) in clinical situations demanding faster MRI-brain scans. J Neurosci Rural Pract 2024; 15:341-348. [PMID: 38746507 PMCID: PMC11090545 DOI: 10.25259/jnrp_508_2023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2023] [Accepted: 03/10/2024] [Indexed: 05/16/2024] Open
Abstract
Objectives The excellent resolution offered by magnetic resonance imaging (MRI) has a trade-off in the form of scan duration. The purpose of the present study was to assess the clinical utility of echo-planar imaging mix (EPIMix), an echo-planar imaging-based MRI sequence for the brain with a short acquisition time. Materials and Methods This was a retrospective observational study of 50 patients, who could benefit from faster MRI brain scans. The T1, T2, fluid attenuated inversion recovery, diffusion-weighted imaging (DWI), and T2*/susceptibility-weighted imaging sequences were acquired, conventionally and with EPIMix. Conventional and EPIMix images were assessed by two radiologists for overall quality, motion, and susceptibility artifacts and scored on a Likert scale. The scores given for conventional and EPIMix images were compared. The diagnostic performance of EPIMix was also assessed by the ability to detect clinically relevant findings. Results The acquisition time for conventional MRI was 11 min and 45 s and for EPIMix 1 min and 15 s. All EPIMix images were sufficient for diagnostic use. On assessment of the diagnostic performance, it was excellent for ischemic and hemorrhagic strokes. Smaller lesions, lesions adjacent to bone, and post-operative tumors were difficult to identify. Moderate to perfect agreement (Kappa values 0.41-1) was seen between radiologists for all categories except skull base, calvarial, and orbital lesions. Image quality, artifact assessment showed excellent interobserver agreement (>90%) for the scores. All EPIMix images showed reduced motion artifacts. The EPIMix-DWI was comparable to conventional-DWI in terms of quality and artifacts. The remaining sequences showed reduced quality and increased susceptibility. Conclusion The EPIMix has a significantly reduced acquisition time than conventional MRI and could be used instead of conventional MRI in situations demanding faster scans such as suspected acute ischemic or hemorrhagic stroke. In other clinical scenarios, it could help tailor the MRI examination for each patient.
Collapse
Affiliation(s)
- Viswanadh Kalaparti Sri Venkata Ganesh
- Department of Imaging Sciences and Interventional Radiology, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Thiruvananthapuram, Kerala, India
| | - Hari Kishore Kamepalli
- Department of Imaging Sciences and Interventional Radiology, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Thiruvananthapuram, Kerala, India
| | | | - Bejoy Thomas
- Department of Imaging Sciences and Interventional Radiology, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Thiruvananthapuram, Kerala, India
| | - Chandrasekharan Kesavadas
- Department of Imaging Sciences and Interventional Radiology, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Thiruvananthapuram, Kerala, India
| |
Collapse
|
31
|
Haast RAM, Kashyap S, Ivanov D, Yousif MD, DeKraker J, Poser BA, Khan AR. Insights into hippocampal perfusion using high-resolution, multi-modal 7T MRI. Proc Natl Acad Sci U S A 2024; 121:e2310044121. [PMID: 38446857 PMCID: PMC10945835 DOI: 10.1073/pnas.2310044121] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Accepted: 12/26/2023] [Indexed: 03/08/2024] Open
Abstract
We present a comprehensive study on the non-invasive measurement of hippocampal perfusion. Using high-resolution 7 tesla arterial spin labeling (ASL) data, we generated robust perfusion maps and observed significant variations in perfusion among hippocampal subfields, with CA1 exhibiting the lowest perfusion levels. Notably, these perfusion differences were robust and already detectable with 50 perfusion-weighted images per subject, acquired in 5 min. To understand the underlying factors, we examined the influence of image quality metrics, various tissue microstructure and morphometric properties, macrovasculature, and cytoarchitecture. We observed higher perfusion in regions located closer to arteries, demonstrating the influence of vascular proximity on hippocampal perfusion. Moreover, ex vivo cytoarchitectonic features based on neuronal density differences appeared to correlate stronger with hippocampal perfusion than morphometric measures like gray matter thickness. These findings emphasize the interplay between microvasculature, macrovasculature, and metabolic demand in shaping hippocampal perfusion. Our study expands the current understanding of hippocampal physiology and its relevance to neurological disorders. By providing in vivo evidence of perfusion differences between hippocampal subfields, our findings have implications for diagnosis and potential therapeutic interventions. In conclusion, our study provides a valuable resource for extensively characterizing hippocampal perfusion.
Collapse
Affiliation(s)
- Roy A. M. Haast
- Centre of Functional and Metabolic Mapping, Robarts Research Institute, Western University, London, ONN6A 3K7, Canada
| | - Sriranga Kashyap
- Department of Cognitive Neuroscience, Faculty of Psychology and Neuroscience, Maastricht University, Maastricht6200, The Netherlands
- Krembil Brain Institute, University Health Network, Toronto, ONM5G 2C4, Canada
| | - Dimo Ivanov
- Department of Cognitive Neuroscience, Faculty of Psychology and Neuroscience, Maastricht University, Maastricht6200, The Netherlands
| | - Mohamed D. Yousif
- Centre of Functional and Metabolic Mapping, Robarts Research Institute, Western University, London, ONN6A 3K7, Canada
| | - Jordan DeKraker
- Montreal Neurological Institute and Hospital, McGill University, Montreal, QCH3A 0G4, Canada
| | - Benedikt A. Poser
- Department of Cognitive Neuroscience, Faculty of Psychology and Neuroscience, Maastricht University, Maastricht6200, The Netherlands
| | - Ali R. Khan
- Centre of Functional and Metabolic Mapping, Robarts Research Institute, Western University, London, ONN6A 3K7, Canada
| |
Collapse
|
32
|
Ghaderi S, Mohammadi S, Ghaderi K, Kiasat F, Mohammadi M. Marker-controlled watershed algorithm and fuzzy C-means clustering machine learning: automated segmentation of glioblastoma from MRI images in a case series. Ann Med Surg (Lond) 2024; 86:1460-1475. [PMID: 38463066 PMCID: PMC10923355 DOI: 10.1097/ms9.0000000000001756] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2023] [Accepted: 01/16/2024] [Indexed: 03/12/2024] Open
Abstract
Introduction and importance Automated segmentation of glioblastoma multiforme (GBM) from MRI images is crucial for accurate diagnosis and treatment planning. This paper presents a new and innovative approach for automating the segmentation of GBM from MRI images using the marker-controlled watershed segmentation (MCWS) algorithm. Case presentation and methods The technique involves several image processing techniques, including adaptive thresholding, morphological filtering, gradient magnitude calculation, and regional maxima identification. The MCWS algorithm efficiently segments images based on local intensity structures using the watershed transform, and fuzzy c-means (FCM) clustering improves segmentation accuracy. The presented approach achieved improved segmentation accuracy in detecting and segmenting GBM tumours from axial T2-weighted (T2-w) MRI images, as demonstrated by the mean characteristics performance metrics for GBM segmentation (sensitivity: 0.9905, specificity: 0.9483, accuracy: 0.9508, precision: 0.5481, F_measure: 0.7052, and jaccard: 0.9340). Clinical discussion The results of this study underline the importance of reliable and accurate image segmentation for effective diagnosis and treatment planning of GBM tumours. Conclusion The MCWS technique provides an effective and efficient approach for the segmentation of challenging medical images.
Collapse
Affiliation(s)
- Sadegh Ghaderi
- Department of Neuroscience and Addiction Studies, School of Advanced Technologies in Medicine, Tehran University of Medical Sciences, Tehran
| | - Sana Mohammadi
- Department of Medical Sciences, School of Medicine, Iran University of Medical Sciences, Tehran
| | - Kayvan Ghaderi
- Department of Information Technology and Computer Engineering, Faculty of Engineering, University of Kurdistan, Sanandaj
| | - Fereshteh Kiasat
- Department of Information Technology and Computer Engineering, Faculty of Engineering, University of Kurdistan, Sanandaj
| | - Mahdi Mohammadi
- Department of Medical Physics and Biomedical Engineering, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
33
|
Sui Z, Palaniappan P, Brenner J, Paganelli C, Kurz C, Landry G, Riboldi M. Intra-frame motion deterioration effects and deep-learning-based compensation in MR-guided radiotherapy. Med Phys 2024; 51:1899-1917. [PMID: 37665948 DOI: 10.1002/mp.16702] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2023] [Revised: 07/07/2023] [Accepted: 07/31/2023] [Indexed: 09/06/2023] Open
Abstract
BACKGROUND Current commercially available hybrid magnetic resonance linear accelerators (MR-Linac) use 2D+t cine MR imaging to provide intra-fractional motion monitoring. However, given the limited temporal resolution of cine MR imaging, target intra-frame motion deterioration effects, resulting in effective time latency and motion artifacts in the image domain, can be appreciable, especially in the case of fast breathing. PURPOSE The aim of this work is to investigate intra-frame motion deterioration effects in MR-guided radiotherapy (MRgRT) by simulating the motion-corrupted image acquisition, and to explore the feasibility of deep-learning-based compensation approaches, relying on the intra-frame motion information which is spatially and temporally encoded in the raw data (k-space). METHODS An intra-frame motion model was defined to simulate motion-corrupted MR images, with 4D anthropomorphic digital phantoms being exploited to provide ground truth 2D+t cine MR sequences. A total number of 10 digital phantoms were generated for lung cancer patients, with randomly selected eight patients for training or validation and the remaining two for testing. The simulation code served as the data generator, and a dedicated motion pattern perturbation scheme was proposed to build the intra-frame motion database, where three degrees of freedom were designed to guarantee the diversity of intra-frame motion trajectories, enabling a thorough exploration in the domain of the potential anatomical structure positions. U-Nets with three types of loss functions: L1 or L2 loss defined in image or Fourier domain, referred to as NNImgLoss-L1 , NNFloss-L1 and NNL2-Loss were trained to extract information from the motion-corrupted image and used to estimate the ground truth final-position image, corresponding to the end of the acquisition. Images before and after compensation were evaluated in terms of (i) image mean-squared error (MSE) and mean absolute error (MAE), and (ii) accuracy of gross tumor volume (GTV) contouring, based on optical-flow image registration. RESULTS Image degradation caused by intra-frame motion was observed: for a linearly and fully acquired Cartesian readout k-space trajectory, intra-frame motion resulted in an imaging latency of approximately 50% of the acquisition time; in comparison, the motion artifacts exhibited only a negligible contribution to the overall geometric errors. All three compensation models led to a decrease in image MSE/MAE and GTV position offset compared to the motion-corrupted image. In the investigated testing dataset for GTV contouring, the average dice similarity coefficients (DSC) improved from 88% to 96%, and the 95th percentile Hausdorff distance (HD95 ) dropped from 4.8 mm to 2.1 mm. Different models showed slight performance variations across different intra-frame motion amplitude categories: NNImgLoss-L1 excelled for small/medium amplitudes, whereas NNFloss-L1 demonstrated higher DSC median values at larger amplitudes. The saliency maps of the motion-corrupted image highlighted the major contribution of the later acquired k-space data, as well as the edges of the moving anatomical structures at their final positions, during the model inference stage. CONCLUSIONS Our results demonstrate the deep-learning-based approaches have the potential to compensate for intra-frame motion by utilizing the later acquired data to drive the convergence of the earlier acquired k-space components.
Collapse
Affiliation(s)
- Zhuojie Sui
- Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München, Garching, Germany
| | - Prasannakumar Palaniappan
- Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München, Garching, Germany
| | - Jakob Brenner
- Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München, Garching, Germany
| | - Chiara Paganelli
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milano, Italy
| | - Christopher Kurz
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| | - Guillaume Landry
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| | - Marco Riboldi
- Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München, Garching, Germany
| |
Collapse
|
34
|
Yun SD, Küppers F, Shah NJ. Submillimeter fMRI Acquisition Techniques for Detection of Laminar and Columnar Level Brain Activation. J Magn Reson Imaging 2024; 59:747-766. [PMID: 37589385 DOI: 10.1002/jmri.28911] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2023] [Revised: 07/07/2023] [Accepted: 07/07/2023] [Indexed: 08/18/2023] Open
Abstract
Since the first demonstration in the early 1990s, functional MRI (fMRI) has emerged as one of the most powerful, noninvasive neuroimaging tools to probe brain functions. Subsequently, fMRI techniques have advanced remarkably, enabling the acquisition of functional signals with a submillimeter voxel size. This innovation has opened the possibility of investigating subcortical neural activities with respect to the cortical depths or cortical columns. For this purpose, numerous previous works have endeavored to design suitable functional contrast mechanisms and dedicated imaging techniques. Depending on the choice of the functional contrast, functional signals can be detected with high sensitivity or with improved spatial specificity to the actual activation site, and the pertaining issues have been discussed in a number of earlier works. This review paper primarily aims to provide an overview of the subcortical fMRI techniques that allow the acquisition of functional signals with a submillimeter resolution. Here, the advantages and disadvantages of the imaging techniques will be described and compared. We also summarize supplementary imaging techniques that assist in the analysis of the subcortical brain activation for more accurate mapping with reduced geometric deformation. This review suggests that there is no single universally accepted method as the gold standard for subcortical fMRI. Instead, the functional contrast and the corresponding readout imaging technique should be carefully determined depending on the purpose of the study. Due to the technical limitations of current fMRI techniques, most subcortical fMRI studies have only targeted partial brain regions. As a future prospect, the spatiotemporal resolution of fMRI will be pushed to satisfy the community's need for a deeper understanding of whole-brain functions and the underlying connectivity in order to achieve the ultimate goal of a time-resolved and layer-specific spatial scale. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 1.
Collapse
Affiliation(s)
- Seong Dae Yun
- Institute of Neuroscience and Medicine 4, INM-4, Forschungszentrum Jülich, Jülich, Germany
| | - Fabian Küppers
- Institute of Neuroscience and Medicine 4, INM-4, Forschungszentrum Jülich, Jülich, Germany
- RWTH Aachen University, Aachen, Germany
- Institute of Neuroscience and Medicine 11, INM-11, JARA, Forschungszentrum Jülich, Jülich, Germany
| | - N Jon Shah
- Institute of Neuroscience and Medicine 4, INM-4, Forschungszentrum Jülich, Jülich, Germany
- Institute of Neuroscience and Medicine 11, INM-11, JARA, Forschungszentrum Jülich, Jülich, Germany
- JARA - BRAIN - Translational Medicine, Aachen, Germany
- Department of Neurology, RWTH Aachen University, Aachen, Germany
| |
Collapse
|
35
|
Valdés Hernández MDC, Duarte Coello R, Xu W, Bernal J, Cheng Y, Ballerini L, Wiseman SJ, Chappell FM, Clancy U, Jaime García D, Arteaga Reyes C, Zhang JF, Liu X, Hewins W, Stringer M, Doubal F, Thrippleton MJ, Jochems A, Brown R, Wardlaw JM. Influence of threshold selection and image sequence in in-vivo segmentation of enlarged perivascular spaces. J Neurosci Methods 2024; 403:110037. [PMID: 38154663 DOI: 10.1016/j.jneumeth.2023.110037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2023] [Revised: 12/06/2023] [Accepted: 12/17/2023] [Indexed: 12/30/2023]
Abstract
BACKGROUND Growing interest surrounds perivascular spaces (PVS) as a clinical biomarker of brain dysfunction given their association with cerebrovascular risk factors and disease. Neuroimaging techniques allowing quick and reliable quantification are being developed, but, in practice, they require optimisation as their limits of validity are usually unspecified. NEW METHOD We evaluate modifications and alternatives to a state-of-the-art (SOTA) PVS segmentation method that uses a vesselness filter to enhance PVS discrimination, followed by thresholding of its response, applied to brain magnetic resonance images (MRI) from patients with sporadic small vessel disease acquired at 3 T. RESULTS The method is robust against inter-observer differences in threshold selection, but separate thresholds for each region of interest (i.e., basal ganglia, centrum semiovale, and midbrain) are required. Noise needs to be assessed prior to selecting these thresholds, as effect of noise and imaging artefacts can be mitigated with a careful optimisation of these thresholds. PVS segmentation from T1-weighted images alone, misses small PVS, therefore, underestimates PVS count, may overestimate individual PVS volume especially in the basal ganglia, and is susceptible to the inclusion of calcified vessels and mineral deposits. Visual analyses indicated the incomplete and fragmented detection of long and thin PVS as the primary cause of errors, with the Frangi filter coping better than the Jerman filter. COMPARISON WITH EXISTING METHODS Limits of validity to a SOTA PVS segmentation method applied to 3 T MRI with confounding pathology are given. CONCLUSIONS Evidence presented reinforces the STRIVE-2 recommendation of using T2-weighted images for PVS assessment wherever possible. The Frangi filter is recommended for PVS segmentation from MRI, offering robust output against variations in threshold selection and pathology presentation.
Collapse
Affiliation(s)
- Maria Del C Valdés Hernández
- Centre for Clinical Brain Sciences, Department of Neuroimaging Sciences, University of Edinburgh, Edinburgh, UK.
| | - Roberto Duarte Coello
- Centre for Clinical Brain Sciences, Department of Neuroimaging Sciences, University of Edinburgh, Edinburgh, UK
| | - William Xu
- College of Medicine and Veterinary Medicine, University of Edinburgh, Edinburgh, UK
| | - José Bernal
- Centre for Clinical Brain Sciences, Department of Neuroimaging Sciences, University of Edinburgh, Edinburgh, UK; German Centre for Neurodegenerative Diseases (DZNE), Magdeburg, Germany; Institute of Cognitive Neurology and Dementia Research, Otto-von-Guericke University Magdeburg, Magdeburg, Germany
| | - Yajun Cheng
- Department of Neurology, West China Hospital of Sichuan University, Chengdu, China
| | - Lucia Ballerini
- Centre for Clinical Brain Sciences, Department of Neuroimaging Sciences, University of Edinburgh, Edinburgh, UK; University for Foreigner of Perugia, Perugia, Italy
| | - Stewart J Wiseman
- Centre for Clinical Brain Sciences, Department of Neuroimaging Sciences, University of Edinburgh, Edinburgh, UK
| | - Francesca M Chappell
- Centre for Clinical Brain Sciences, Department of Neuroimaging Sciences, University of Edinburgh, Edinburgh, UK
| | - Una Clancy
- Centre for Clinical Brain Sciences, Department of Neuroimaging Sciences, University of Edinburgh, Edinburgh, UK
| | - Daniela Jaime García
- Centre for Clinical Brain Sciences, Department of Neuroimaging Sciences, University of Edinburgh, Edinburgh, UK
| | - Carmen Arteaga Reyes
- Centre for Clinical Brain Sciences, Department of Neuroimaging Sciences, University of Edinburgh, Edinburgh, UK
| | - Jun-Fang Zhang
- Centre for Clinical Brain Sciences, Department of Neuroimaging Sciences, University of Edinburgh, Edinburgh, UK; Department of Neurology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Xiaodi Liu
- Division of Neurology, Department of Medicine, The University of Hong Kong, Hong Kong
| | - Will Hewins
- Centre for Clinical Brain Sciences, Department of Neuroimaging Sciences, University of Edinburgh, Edinburgh, UK
| | - Michael Stringer
- Centre for Clinical Brain Sciences, Department of Neuroimaging Sciences, University of Edinburgh, Edinburgh, UK
| | - Fergus Doubal
- Centre for Clinical Brain Sciences, Department of Neuroimaging Sciences, University of Edinburgh, Edinburgh, UK
| | - Michael J Thrippleton
- Centre for Clinical Brain Sciences, Department of Neuroimaging Sciences, University of Edinburgh, Edinburgh, UK
| | - Angela Jochems
- Centre for Clinical Brain Sciences, Department of Neuroimaging Sciences, University of Edinburgh, Edinburgh, UK
| | - Rosalind Brown
- Centre for Clinical Brain Sciences, Department of Neuroimaging Sciences, University of Edinburgh, Edinburgh, UK
| | - Joanna M Wardlaw
- Centre for Clinical Brain Sciences, Department of Neuroimaging Sciences, University of Edinburgh, Edinburgh, UK
| |
Collapse
|
36
|
Zhou Z, Hu P, Qi H. Stop moving: MR motion correction as an opportunity for artificial intelligence. MAGMA (NEW YORK, N.Y.) 2024:10.1007/s10334-023-01144-5. [PMID: 38386151 DOI: 10.1007/s10334-023-01144-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Revised: 12/09/2023] [Accepted: 12/19/2023] [Indexed: 02/23/2024]
Abstract
Subject motion is a long-standing problem of magnetic resonance imaging (MRI), which can seriously deteriorate the image quality. Various prospective and retrospective methods have been proposed for MRI motion correction, among which deep learning approaches have achieved state-of-the-art motion correction performance. This survey paper aims to provide a comprehensive review of deep learning-based MRI motion correction methods. Neural networks used for motion artifacts reduction and motion estimation in the image domain or frequency domain are detailed. Furthermore, besides motion-corrected MRI reconstruction, how estimated motion is applied in other downstream tasks is briefly introduced, aiming to strengthen the interaction between different research areas. Finally, we identify current limitations and point out future directions of deep learning-based MRI motion correction.
Collapse
Affiliation(s)
- Zijian Zhou
- School of Biomedical Engineering, ShanghaiTech University, 4th Floor, BME Building, 393 Middle Huaxia Road, Pudong District, Shanghai, 201210, China
- Shanghai Clinical Research and Trial Center, ShanghaiTech University, Shanghai, China
| | - Peng Hu
- School of Biomedical Engineering, ShanghaiTech University, 4th Floor, BME Building, 393 Middle Huaxia Road, Pudong District, Shanghai, 201210, China.
- Shanghai Clinical Research and Trial Center, ShanghaiTech University, Shanghai, China.
| | - Haikun Qi
- School of Biomedical Engineering, ShanghaiTech University, 4th Floor, BME Building, 393 Middle Huaxia Road, Pudong District, Shanghai, 201210, China.
- Shanghai Clinical Research and Trial Center, ShanghaiTech University, Shanghai, China.
| |
Collapse
|
37
|
Wulms N, Kugel H, Cnyrim C, Tenberge A, Schwindt W, Dannlowski U, Berger K, Sundermann B, Minnerup H. Cerebral MRI in a prospective cohort study on depression and atherosclerosis: the BiDirect sample, processing pipelines, and analysis tools. Eur Radiol Exp 2024; 8:16. [PMID: 38332362 PMCID: PMC10853141 DOI: 10.1186/s41747-023-00415-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Accepted: 11/23/2023] [Indexed: 02/10/2024] Open
Abstract
BACKGROUND The use of cerebral magnetic resonance imaging (MRI) in observational studies has increased exponentially in recent years, making it critical to provide details about the study sample, image processing, and extracted imaging markers to validate and replicate study results. This article reviews the cerebral MRI dataset from the now-completed BiDirect cohort study, as an update and extension of the feasibility report published after the first two examination time points. METHODS We report the sample and flow of participants spanning four study sessions and twelve years. In addition, we provide details on the acquisition protocol; the processing pipelines, including standardization and quality control methods; and the analytical tools used and markers available. RESULTS All data were collected from 2010 to 2021 at a single site in Münster, Germany, starting with a population of 2,257 participants at baseline in 3 different cohorts: a population-based cohort (n = 911 at baseline, 672 with MRI data), patients diagnosed with depression (n = 999, 736 with MRI data), and patients with manifest cardiovascular disease (n = 347, 52 with MRI data). During the study period, a total of 4,315 MRI sessions were performed, and over 535 participants underwent MRI at all 4 time points. CONCLUSIONS Images were converted to Brain Imaging Data Structure (a standard for organizing and describing neuroimaging data) and analyzed using common tools, such as CAT12, FSL, Freesurfer, and BIANCA to extract imaging biomarkers. The BiDirect study comprises a thoroughly phenotyped study population with structural and functional MRI data. RELEVANCE STATEMENT The BiDirect Study includes a population-based sample and two patient-based samples whose MRI data can help answer numerous neuropsychiatric and cardiovascular research questions. KEY POINTS • The BiDirect study included characterized patient- and population-based cohorts with MRI data. • Data were standardized to Brain Imaging Data Structure and processed with commonly available software. • MRI data and markers are available upon request.
Collapse
Affiliation(s)
- Niklas Wulms
- Institute of Epidemiology and Social Medicine, University of Münster, Münster, Germany.
| | - Harald Kugel
- Clinic of Radiology Radiology, University Hospital Muenster, Münster, Germany
| | - Christian Cnyrim
- Department of Clinical Radiology, Klinikum Ibbenbueren, Ibbenbueren, Germany
| | - Anja Tenberge
- Institute of Epidemiology and Social Medicine, University of Münster, Münster, Germany
| | - Wolfram Schwindt
- Clinic of Radiology Radiology, University Hospital Muenster, Münster, Germany
| | - Udo Dannlowski
- Institute for Translational Psychiatry, University of Münster, Münster, Germany
| | - Klaus Berger
- Institute of Epidemiology and Social Medicine, University of Münster, Münster, Germany
| | - Benedikt Sundermann
- Clinic of Radiology Radiology, University Hospital Muenster, Münster, Germany
- Institute of Radiology and Neuroradiology, Evangelisches Krankenhaus, Medical Campus, University of Oldenburg, Oldenburg, Germany
- Research Center Neurosensory Science, University of Oldenburg, Oldenburg, Germany
| | - Heike Minnerup
- Institute of Epidemiology and Social Medicine, University of Münster, Münster, Germany
| |
Collapse
|
38
|
Voineskos AN, Hawco C, Neufeld NH, Turner JA, Ameis SH, Anticevic A, Buchanan RW, Cadenhead K, Dazzan P, Dickie EW, Gallucci J, Lahti AC, Malhotra AK, Öngür D, Lencz T, Sarpal DK, Oliver LD. Functional magnetic resonance imaging in schizophrenia: current evidence, methodological advances, limitations and future directions. World Psychiatry 2024; 23:26-51. [PMID: 38214624 PMCID: PMC10786022 DOI: 10.1002/wps.21159] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/13/2024] Open
Abstract
Functional neuroimaging emerged with great promise and has provided fundamental insights into the neurobiology of schizophrenia. However, it has faced challenges and criticisms, most notably a lack of clinical translation. This paper provides a comprehensive review and critical summary of the literature on functional neuroimaging, in particular functional magnetic resonance imaging (fMRI), in schizophrenia. We begin by reviewing research on fMRI biomarkers in schizophrenia and the clinical high risk phase through a historical lens, moving from case-control regional brain activation to global connectivity and advanced analytical approaches, and more recent machine learning algorithms to identify predictive neuroimaging features. Findings from fMRI studies of negative symptoms as well as of neurocognitive and social cognitive deficits are then reviewed. Functional neural markers of these symptoms and deficits may represent promising treatment targets in schizophrenia. Next, we summarize fMRI research related to antipsychotic medication, psychotherapy and psychosocial interventions, and neurostimulation, including treatment response and resistance, therapeutic mechanisms, and treatment targeting. We also review the utility of fMRI and data-driven approaches to dissect the heterogeneity of schizophrenia, moving beyond case-control comparisons, as well as methodological considerations and advances, including consortia and precision fMRI. Lastly, limitations and future directions of research in the field are discussed. Our comprehensive review suggests that, in order for fMRI to be clinically useful in the care of patients with schizophrenia, research should address potentially actionable clinical decisions that are routine in schizophrenia treatment, such as which antipsychotic should be prescribed or whether a given patient is likely to have persistent functional impairment. The potential clinical utility of fMRI is influenced by and must be weighed against cost and accessibility factors. Future evaluations of the utility of fMRI in prognostic and treatment response studies may consider including a health economics analysis.
Collapse
Affiliation(s)
- Aristotle N Voineskos
- Campbell Family Mental Health Research Institute and Brain Health Imaging Centre, Centre for Addiction and Mental Health, Toronto, ON, Canada
- Department of Psychiatry, Temerty Faculty of Medicine, University of Toronto, Toronto, ON, Canada
| | - Colin Hawco
- Campbell Family Mental Health Research Institute and Brain Health Imaging Centre, Centre for Addiction and Mental Health, Toronto, ON, Canada
- Department of Psychiatry, Temerty Faculty of Medicine, University of Toronto, Toronto, ON, Canada
| | - Nicholas H Neufeld
- Campbell Family Mental Health Research Institute and Brain Health Imaging Centre, Centre for Addiction and Mental Health, Toronto, ON, Canada
- Department of Psychiatry, Temerty Faculty of Medicine, University of Toronto, Toronto, ON, Canada
| | - Jessica A Turner
- Department of Psychiatry and Behavioral Health, Wexner Medical Center, Ohio State University, Columbus, OH, USA
| | - Stephanie H Ameis
- Campbell Family Mental Health Research Institute and Brain Health Imaging Centre, Centre for Addiction and Mental Health, Toronto, ON, Canada
- Department of Psychiatry, Temerty Faculty of Medicine, University of Toronto, Toronto, ON, Canada
- Cundill Centre for Child and Youth Depression and McCain Centre for Child, Youth and Family Mental Health, Centre for Addiction and Mental Health, Toronto, ON, Canada
| | - Alan Anticevic
- Interdepartmental Neuroscience Program, Yale University, New Haven, CT, USA
- Department of Psychiatry, Yale University, New Haven, CT, USA
| | - Robert W Buchanan
- Maryland Psychiatric Research Center, Department of Psychiatry, University of Maryland School of Medicine, Baltimore, MD, USA
| | - Kristin Cadenhead
- Department of Psychiatry, University of California San Diego, La Jolla, CA, USA
| | - Paola Dazzan
- Department of Psychological Medicine, Institute of Psychiatry, Psychology and Neuroscience, King's College London, London, UK
| | - Erin W Dickie
- Campbell Family Mental Health Research Institute and Brain Health Imaging Centre, Centre for Addiction and Mental Health, Toronto, ON, Canada
- Department of Psychiatry, Temerty Faculty of Medicine, University of Toronto, Toronto, ON, Canada
| | - Julia Gallucci
- Campbell Family Mental Health Research Institute and Brain Health Imaging Centre, Centre for Addiction and Mental Health, Toronto, ON, Canada
- Institute of Medical Science, University of Toronto, Toronto, ON, Canada
| | - Adrienne C Lahti
- Department of Psychiatry and Behavioral Neurobiology, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Anil K Malhotra
- Institute for Behavioral Science, Feinstein Institutes for Medical Research, Manhasset, NY, USA
- Department of Psychiatry, Zucker School of Medicine at Hofstra/Northwell, Hempstead, NY, USA
- Department of Molecular Medicine, Zucker School of Medicine at Hofstra/Northwell, Hempstead, NY, USA
- Department of Psychiatry, Zucker Hillside Hospital Division of Northwell Health, Glen Oaks, NY, USA
| | - Dost Öngür
- McLean Hospital/Harvard Medical School, Belmont, MA, USA
| | - Todd Lencz
- Institute for Behavioral Science, Feinstein Institutes for Medical Research, Manhasset, NY, USA
- Department of Psychiatry, Zucker School of Medicine at Hofstra/Northwell, Hempstead, NY, USA
- Department of Molecular Medicine, Zucker School of Medicine at Hofstra/Northwell, Hempstead, NY, USA
- Department of Psychiatry, Zucker Hillside Hospital Division of Northwell Health, Glen Oaks, NY, USA
| | - Deepak K Sarpal
- Department of Psychiatry, School of Medicine, University of Pittsburgh, Pittsburgh, PA, USA
| | - Lindsay D Oliver
- Campbell Family Mental Health Research Institute and Brain Health Imaging Centre, Centre for Addiction and Mental Health, Toronto, ON, Canada
| |
Collapse
|
39
|
Liu H, van der Heide O, Versteeg E, Froeling M, Fuderer M, Xu F, van den Berg CAT, Sbrizzi A. A three-dimensional Magnetic Resonance Spin Tomography in Time-domain protocol for high-resolution multiparametric quantitative magnetic resonance imaging. NMR IN BIOMEDICINE 2024; 37:e5050. [PMID: 37857335 DOI: 10.1002/nbm.5050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/10/2023] [Revised: 08/04/2023] [Accepted: 09/11/2023] [Indexed: 10/21/2023]
Abstract
Magnetic Resonance Spin TomogrAphy in Time-domain (MR-STAT) is a multiparametric quantitative MR framework, which allows for simultaneously acquiring quantitative tissue parameters such as T1, T2, and proton density from one single short scan. A typical two-dimensional (2D) MR-STAT acquisition uses a gradient-spoiled, gradient-echo sequence with a slowly varying RF flip-angle train and Cartesian readouts, and the quantitative tissue maps are reconstructed by an iterative, model-based optimization algorithm. In this work, we design a three-dimensional (3D) MR-STAT framework based on previous 2D work, in order to achieve better image signal-to-noise ratio, higher though-plane resolution, and better tissue characterization. Specifically, we design a 7-min, high-resolution 3D MR-STAT sequence, and the corresponding two-step reconstruction algorithm for the large-scale dataset. To reduce the long acquisition time, Cartesian undersampling strategies such as SENSE are adopted in our transient-state quantitative framework. To reduce the computational burden, a data-splitting scheme is designed for decoupling the 3D reconstruction problem into independent 2D reconstructions. The proposed 3D framework is validated by numerical simulations, phantom experiments, and in vivo experiments. High-quality knee quantitative maps with 0.8 × 0.8 × 1.5 mm3 resolution and bilateral lower leg maps with 1.6 mm isotropic resolution can be acquired using the proposed 7-min acquisition sequence and the 3-min-per-slice decoupled reconstruction algorithm. The proposed 3D MR-STAT framework could have wide clinical applications in the future.
Collapse
Affiliation(s)
- Hongyan Liu
- Computational Imaging Group for MRI Therapy & Diagnostics, Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Oscar van der Heide
- Computational Imaging Group for MRI Therapy & Diagnostics, Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Edwin Versteeg
- Computational Imaging Group for MRI Therapy & Diagnostics, Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Martijn Froeling
- Department of Radiology, Imaging Division, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Miha Fuderer
- Computational Imaging Group for MRI Therapy & Diagnostics, Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Fei Xu
- Computational Imaging Group for MRI Therapy & Diagnostics, Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Cornelis A T van den Berg
- Computational Imaging Group for MRI Therapy & Diagnostics, Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Alessandro Sbrizzi
- Computational Imaging Group for MRI Therapy & Diagnostics, Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
| |
Collapse
|
40
|
Colaço D. When remediating one artifact results in another: control, confounders, and correction. HISTORY AND PHILOSOPHY OF THE LIFE SCIENCES 2024; 46:5. [PMID: 38206408 PMCID: PMC10784372 DOI: 10.1007/s40656-023-00606-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/08/2023] [Accepted: 12/21/2023] [Indexed: 01/12/2024]
Abstract
Scientists aim to remediate artifacts in their experimental datasets. However, the remediation of one artifact can result in another. Why might this happen, and what does this consequence tell us about how we should account for artifacts and their control? In this paper, I explore a case in functional neuroimaging where remediation appears to have caused this problem. I argue that remediation amounts to a change to an experimental arrangement. These changes need not be surgical, and the arrangement need not satisfy the criterion of causal modularity. Thus, remediation can affect more than just the factor responsible for the artifact. However, if researchers can determine the consequences of their remediation, they can make adjustments that control for the present artifact as well as for previously controlled ones. Current philosophical accounts of artifacts and the factors responsible for them cannot adequately address this issue, as they do not account for what is needed for artifact remediation (and specifically correction). I support my argument by paralleling it with ongoing concerns regarding the transparency of complex computational systems, as near future remediation across the experimental life sciences will likely make greater use of AI tools to correct for artifacts.
Collapse
Affiliation(s)
- David Colaço
- Munich Center for Mathematical Philosophy, LMU Munich, Munich, Germany.
| |
Collapse
|
41
|
Li Y, Joaquim MR, Pickup S, Song HK, Zhou R, Fan Y. Learning ADC maps from accelerated radial k-space diffusion-weighted MRI in mice using a deep CNN-transformer model. Magn Reson Med 2024; 91:105-117. [PMID: 37598398 PMCID: PMC10691280 DOI: 10.1002/mrm.29833] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2023] [Revised: 07/26/2023] [Accepted: 07/31/2023] [Indexed: 08/22/2023]
Abstract
PURPOSE To accelerate radially sampled diffusion weighted spin-echo (Rad-DW-SE) acquisition method for generating high quality ADC maps. METHODS A deep learning method was developed to generate accurate ADC maps from accelerated DWI data acquired with the Rad-DW-SE method. The deep learning method integrates convolutional neural networks (CNNs) with vision transformers to generate high quality ADC maps from accelerated DWI data, regularized by a monoexponential ADC model fitting term. A model was trained on DWI data of 147 mice and evaluated on DWI data of 36 mice, with acceleration factors of 4× and 8× compared to the original acquisition parameters. RESULTS Ablation studies and experimental results have demonstrated that the proposed deep learning model generates higher quality ADC maps from accelerated DWI data than alternative deep learning methods under comparison when their performance is quantified in whole images as well as in regions of interest, including tumors, kidneys, and muscles. CONCLUSIONS The deep learning method with integrated CNNs and transformers provides an effective means to accurately compute ADC maps from accelerated DWI data acquired with the Rad-DW-SE method.
Collapse
Affiliation(s)
- Yuemeng Li
- Center for Biomedical Image Computing and Analytics (CBICA), Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Miguel Romanello Joaquim
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Stephen Pickup
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Hee Kwon Song
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Rong Zhou
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA
- Abramson Cancer Center, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Yong Fan
- Center for Biomedical Image Computing and Analytics (CBICA), Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA
| |
Collapse
|
42
|
Ohira S, Suzuki Y, Washio H, Yamamoto Y, Tateishi S, Inui S, Kanayama N, Kawamata M, Miyazaki M, Nishio T, Koizumi M, Nakanishi K, Konishi K. Impact of magnetic resonance imaging-related geometric distortion of dose distribution in fractionated stereotactic radiotherapy in patients with brain metastases. Strahlenther Onkol 2024; 200:39-48. [PMID: 37591978 DOI: 10.1007/s00066-023-02120-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2023] [Accepted: 07/10/2023] [Indexed: 08/19/2023]
Abstract
PURPOSE The geometric distortion related to magnetic resonance (MR) imaging in a diagnostic radiology (MRDR) and radiotherapy (MRRT) setup is evaluated, and the dosimetric impact of MR distortion on fractionated stereotactic radiotherapy (FSRT) in patients with brain metastases is simulated. MATERIALS AND METHODS An anthropomorphic skull phantom was scanned using a 1.5‑T MR scanner, and the magnitude of MR distortion was calculated with (MRDR-DC and MRRT-DC) and without (MRDR-nDC and MRRT-nDC) distortion-correction algorithms. Automated noncoplanar volumetric modulated arc therapy (HyperArc, HA; Varian Medical Systems, Palo Alto, CA, USA) plans were generated for 53 patients with 186 brain metastases. The MR distortion at each gross tumor volume (GTV) was calculated using the distance between the center of the GTV and the MR image isocenter (MIC) and the quadratic regression curve derived from the phantom study (MRRT-DC and MRRT-nDC). Subsequently, the radiation isocenter of the HA plans was shifted according to the MR distortion at each GTV (HADC and HAnDC). RESULTS The median MR distortions were approximately 0.1 mm when the distance from the MIC was < 30 mm, whereas the median distortion varied widely when the distance was > 60 mm (0.23, 0.47, 0.37, and 0.57 mm in MRDR-DC, MRDR-nDC, MRRT-DC, and MRRT-nDC, respectively). The dose to the 98% of the GTV volume (D98%) decreased as the distance from the MIC increased. In the HADC plans, the relative dose difference of D98% was less than 5% when the GTV was located within 70 mm from the MIC, whereas the underdose of GTV exceeded 5% when it was 48 mm (-26.5% at maximum) away from the MIC in the HAnDC plans. CONCLUSION Use of a distortion-correction algorithm in the studied MR diagnoses is essential, and the dosimetric impact of MR distortion is not negligible, particularly for tumors located far away from the MIC.
Collapse
Affiliation(s)
- Shingo Ohira
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan.
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita, Japan.
| | - Yuta Suzuki
- Department of Diagnostic and Interventional Radiology, Osaka International Cancer Institute, Osaka, Japan
| | - Hayate Washio
- Department of Diagnostic and Interventional Radiology, Osaka International Cancer Institute, Osaka, Japan
| | - Yuki Yamamoto
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita, Japan
| | - Soichiro Tateishi
- Department of Diagnostic and Interventional Radiology, Osaka International Cancer Institute, Osaka, Japan
| | - Shoki Inui
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Naoyuki Kanayama
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Minoru Kawamata
- Department of Diagnostic and Interventional Radiology, Osaka International Cancer Institute, Osaka, Japan
| | - Masayoshi Miyazaki
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Teiji Nishio
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita, Japan
| | - Masahiko Koizumi
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita, Japan
| | - Katsuyuki Nakanishi
- Department of Diagnostic and Interventional Radiology, Osaka International Cancer Institute, Osaka, Japan
| | - Koji Konishi
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| |
Collapse
|
43
|
Barrett T, Lee KL, de Rooij M, Giganti F. Update on Optimization of Prostate MR Imaging Technique and Image Quality. Radiol Clin North Am 2024; 62:1-15. [PMID: 37973236 DOI: 10.1016/j.rcl.2023.06.006] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2023]
Abstract
Prostate MR imaging quality has improved dramatically over recent times, driven by advances in hardware, software, and improved functional imaging techniques. MRI now plays a key role in prostate cancer diagnostic work-up, but outcomes of the MRI-directed pathway are heavily dependent on image quality and optimization. MR sequences can be affected by patient-related degradations relating to motion and susceptibility artifacts which may enable only partial mitigation. In this Review, we explore issues relating to prostate MRI acquisition and interpretation, mitigation strategies at a patient and scanner level, PI-QUAL reporting, and future directions in image quality, including artificial intelligence solutions.
Collapse
Affiliation(s)
- Tristan Barrett
- Department of Radiology, Addenbrooke's Hospital and University of Cambridge, Cambridge, UK.
| | - Kang-Lung Lee
- Department of Radiology, Addenbrooke's Hospital and University of Cambridge, Cambridge, UK; Department of Radiology, Taipei Veterans General Hospital, Taipei, Taiwan; School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Maarten de Rooij
- Department of Medical Imaging, Radboud University Medical Center, Nijmegen, Netherlands
| | - Francesco Giganti
- Department of Radiology, University College London Hospital NHS Foundation Trust, London, UK; Division of Surgery and Interventional Science, University College London, London, UK
| |
Collapse
|
44
|
Kompel A, Guermazi A. Imaging of MSK infections in the ER. Skeletal Radiol 2023:10.1007/s00256-023-04554-7. [PMID: 38147081 DOI: 10.1007/s00256-023-04554-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/06/2023] [Revised: 12/10/2023] [Accepted: 12/17/2023] [Indexed: 12/27/2023]
Abstract
Musculoskeletal infections in the ER are not an uncommon presentation. The clinical context is critical in determining the suspicion for infection and degree of tissue involvement which can involve all layers from the skin to bones. The location, extent, and severity of clinically suspected infection directly relate to the type of imaging performed. Uncomplicated cellulitis typically does not require any imaging. Localized and superficial infections can mostly be evaluated with ultrasound. If there is a diffuse site (an entire extremity) or suspected deeper involvement (muscle/deep fascia), then CT is accurate in diagnosing, widely available, and performed quickly. With potential osseous involvement, MRI is the gold standard for diagnosing acute osteomyelitis; however, it has the drawbacks of longer scan times, artifacts including patient motion, and limited availability.
Collapse
Affiliation(s)
- Andrew Kompel
- Boston University School of Medicine, Boston, MA, USA.
| | - Ali Guermazi
- Boston University School of Medicine, Boston, MA, USA
- Boston VA Healthcare System, West Roxbury, MA, USA
| |
Collapse
|
45
|
Wang L, Li T, Cai J, Chang HC. Motion-resolved four-dimensional abdominal diffusion-weighted imaging using PROPELLER EPI (4D-DW-PROPELLER-EPI). Magn Reson Med 2023; 90:2454-2471. [PMID: 37486854 DOI: 10.1002/mrm.29802] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2023] [Revised: 06/22/2023] [Accepted: 07/03/2023] [Indexed: 07/26/2023]
Abstract
PURPOSE To develop a distortion-free motion-resolved four-dimensional diffusion-weighted PROPELLER EPI (4D-DW-PROPELLER-EPI) technique for benefiting clinical abdominal radiotherapy (RT). METHODS An improved abdominal 4D-DWI technique based on 2D diffusion-weighted PROPELLER-EPI (2D-DW-PROPELLER-EPI), termed 4D-DW-PROPELLER-EPI, was proposed to improve the frame rate of repeated data acquisition and produce distortion-free 4D-DWI images. Since the radial or PROPELLER sampling with golden-angle rotation can achieve an efficient k-space coverage with a flexible time-resolved acquisition, the golden-angle multi-blade acquisition was used in the proposed 4D-DW-PROPELLER-EPI to improve the performance of data sorting. A new k-space and blade (K-B) amplitude binning method was developed for the proposed 4D-DW-PROPELLER-EPI to optimize the number of blades and the k-space uniformity before performing conventional PROPELLER-EPI reconstruction, by using two metrics to evaluate the adequacy of the acquired data. The proposed 4D-DW-PROPELLER-EPI was preliminarily evaluated in both simulation experiments and in vivo experiments with varying frame rates and different numbers of repeated acquisition. RESULTS The feasibility of achieving distortion-free 4D-DWI images by using the proposed 4D-DW-PROPELLER-EPI technique was demonstrated in both digital phantom and healthy subjects. Evaluation of the 4D completeness metrics shows that the K-B amplitude binning method could simultaneously improve the acquisition efficiency and data reconstruction performance for 4D-DW-PROPELLER-EPI. CONCLUSION 4D-DW-PROPELLER-EPI with K-B amplitude binning is an advanced technique that can provide distortion-free 4D-DWI images for resolving respiratory motion, and may benefit the application of image-guided abdominal RT.
Collapse
Affiliation(s)
- Lu Wang
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, Hong Kong
- Department of Diagnostic Radiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong, Hong Kong
| | - Tian Li
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, Hong Kong
| | - Jing Cai
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, Hong Kong
| | - Hing-Chiu Chang
- Department of Biomedical Engineering, The Chinese University of Hong Kong, Hong Kong, Hong Kong
- Multi-Scale Medical Robotics Center, The Chinese University of Hong Kong, Hong Kong, Hong Kong
| |
Collapse
|
46
|
Shafique M, Qazi SA, Omer H. Compressed SVD-based L + S model to reconstruct undersampled dynamic MRI data using parallel architecture. MAGMA (NEW YORK, N.Y.) 2023:10.1007/s10334-023-01128-5. [PMID: 37978992 DOI: 10.1007/s10334-023-01128-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Revised: 09/27/2023] [Accepted: 10/20/2023] [Indexed: 11/19/2023]
Abstract
BACKGROUND Magnetic Resonance Imaging (MRI) is a highly demanded medical imaging system due to high resolution, large volumetric coverage, and ability to capture the dynamic and functional information of body organs e.g. cardiac MRI is employed to assess cardiac structure and evaluate blood flow dynamics through the cardiac valves. Long scan time is the main drawback of MRI, which makes it difficult for the patients to remain still during the scanning process. OBJECTIVE By collecting fewer measurements, MRI scan time can be shortened, but this undersampling causes aliasing artifacts in the reconstructed images. Advanced image reconstruction algorithms have been used in literature to overcome these undersampling artifacts. These algorithms are computationally expensive and require a long time for reconstruction which makes them infeasible for real-time clinical applications e.g. cardiac MRI. However, exploiting the inherent parallelism in these algorithms can help to reduce their computation time. METHODS Low-rank plus sparse (L+S) matrix decomposition model is a technique used in literature to reconstruct the highly undersampled dynamic MRI (dMRI) data at the expense of long reconstruction time. In this paper, Compressed Singular Value Decomposition (cSVD) model is used in L+S decomposition model (instead of conventional SVD) to reduce the reconstruction time. The results provide improved quality of the reconstructed images. Furthermore, it has been observed that cSVD and other parts of the L+S model possess highly parallel operations; therefore, a customized GPU based parallel architecture of the modified L+S model has been presented to further reduce the reconstruction time. RESULTS Four cardiac MRI datasets (three different cardiac perfusion acquired from different patients and one cardiac cine data), each with different acceleration factors of 2, 6 and 8 are used for experiments in this paper. Experimental results demonstrate that using the proposed parallel architecture for the reconstruction of cardiac perfusion data provides a speed-up factor up to 19.15× (with memory latency) and 70.55× (without memory latency) in comparison to the conventional CPU reconstruction with no compromise on image quality. CONCLUSION The proposed method is well-suited for real-time clinical applications, offering a substantial reduction in reconstruction time.
Collapse
Affiliation(s)
- Muhammad Shafique
- Medical Image Processing Research Group (MIPRG), Department of Electrical and Computer Engineering, COMSATS University Islamabad, Islamabad, Pakistan.
- Department of Electrical Engineering, University of Poonch Rawalakot, Rawalakot, AJ&K, Pakistan.
| | - Sohaib Ayaz Qazi
- Cardiovascular Sciences, Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | - Hammad Omer
- Medical Image Processing Research Group (MIPRG), Department of Electrical and Computer Engineering, COMSATS University Islamabad, Islamabad, Pakistan
| |
Collapse
|
47
|
Lee MS, Moon MH, Kim TM, Jang S, Oh S, Cho JY. Contrast-Enhanced MRI in Women with Endometrial Cancer: Dynamic Versus Single-Phase Acquisitions. Clin Med Insights Oncol 2023; 17:11795549231207833. [PMID: 38023285 PMCID: PMC10644739 DOI: 10.1177/11795549231207833] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Accepted: 09/28/2023] [Indexed: 12/01/2023] Open
Abstract
Background The 2019 European Society of Urogenital Radiology (ESUR) guidelines for endometrial cancer recommend performing either dynamic contrast-enhanced magnetic resonance imaging (CE MRI) or single-phase CE MRI. However, no study has directly compared these options. Therefore, this study compared dynamic versus single-phase CE MRI for the evaluation of myometrial invasion in women with endometrial cancer. Methods This retrospective, single-institution comparative study was conducted among women with surgically proven endometrial cancer, including 30 consecutive women with single-phase CE MRI and 30 age- and pathologic stage-matched women with dynamic CE MRI. Three readers independently compared dynamic and single-phase CE MRI in terms of the tumor-myometrium signal intensity (SI) difference ratio, depth of myometrial invasion, image quality, and image number. Pathologic findings served as a reference standard for the depth of myometrial invasion. Results The estimated mean SI difference ratios of dynamic CE MRI and single-phase CE MRI fell within an equivalence margin of 0.05 (90% confidence intervals [CIs] = [-0.0497 to -0.0165], [-0.0226 to -0.0403], and [-0.0429 to -0.0433], respectively, for readers A, B, and C). The area under the receiver operating characteristic curve for the detection of deep myometrial invasion was not significantly different between the acquisitions (P = .3315, P = .3345, and P = .8593, respectively). Single-phase CE MRI showed significantly better image quality than dynamic CE MRI (P = .0143, P = .0042, and P = .0066, respectively), while the median number of images for dynamic CE MRI was 2.4 times higher than that for single-phase CE MRI. Conclusion Single-phase acquisition may be a better option for CE MRI in women with endometrial cancer than dynamic acquisition.
Collapse
Affiliation(s)
- Myoung Seok Lee
- Department of Radiology, Seoul National University Seoul Metropolitan Government Boramae Medical Center, Seoul, South Korea
| | - Min Hoan Moon
- Department of Radiology, Seoul National University Seoul Metropolitan Government Boramae Medical Center, Seoul, South Korea
| | - Taek Min Kim
- Department of Radiology, Seoul National University Hospital, Seoul, South Korea
| | - Siwon Jang
- Department of Radiology, Seoul National University Seoul Metropolitan Government Boramae Medical Center, Seoul, South Korea
| | - Sohee Oh
- Medical Research Collaborating Center, Seoul National University Seoul Metropolitan Government Boramae Medical Center, Seoul, South Korea
| | - Jeong Yeon Cho
- Department of Radiology, Seoul National University Hospital, Seoul, South Korea
| |
Collapse
|
48
|
Heij J, Raimondo L, Siero JCW, Dumoulin SO, van der Zwaag W, Knapen T. A selection and targeting framework of cortical locations for line-scanning fMRI. Hum Brain Mapp 2023; 44:5471-5484. [PMID: 37608563 PMCID: PMC10543358 DOI: 10.1002/hbm.26459] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2023] [Revised: 07/15/2023] [Accepted: 08/02/2023] [Indexed: 08/24/2023] Open
Abstract
Depth-resolved functional magnetic resonance imaging (fMRI) is an emerging field growing in popularity given the potential of separating signals from different computational processes in cerebral cortex. Conventional acquisition schemes suffer from low spatial and temporal resolutions. Line-scanning methods allow depth-resolved fMRI by sacrificing spatial coverage to sample blood oxygenated level-dependent (BOLD) responses at ultra-high temporal and spatial resolution. For neuroscience applications, it is critical to be able to place the line accurately to (1) sample the right neural population and (2) target that neural population with tailored stimuli or tasks. To this end, we devised a multi-session framework where a target cortical location is selected based on anatomical and functional properties. The line is then positioned according to this information in a separate second session, and we tailor the experiment to focus on the target location. Anatomically, the precision of the line placement was confirmed by projecting a nominal representation of the acquired line back onto the surface. Functional estimates of neural selectivities in the line, as quantified by a visual population-receptive field model, resembled the target selectivities well for most subjects. This functional precision was quantified in detail by estimating the distance between the visual field location of the targeted vertex and the location in visual cortex (V1) that most closely resembled the line-scanning estimates; this distance was on average ~5.5 mm. Given the dimensions of the line, differences in acquisition, session, and stimulus design, this validates that line-scanning can be used to probe local neural sensitivities across sessions. In summary, we present an accurate framework for line-scanning MRI; we believe such a framework is required to harness the full potential of line-scanning and maximize its utility. Furthermore, this approach bridges canonical fMRI experiments with electrophysiological experiments, which in turn allows novel avenues for studying human physiology non-invasively.
Collapse
Affiliation(s)
- Jurjen Heij
- Spinoza Centre for NeuroimagingAmsterdamNetherlands
- Department of Computational Cognitive Neuroscience and NeuroimagingNetherlands Institute for NeuroscienceAmsterdamNetherlands
- Department of Experimental and Applied PsychologyVU UniversityAmsterdamNetherlands
| | - Luisa Raimondo
- Spinoza Centre for NeuroimagingAmsterdamNetherlands
- Department of Computational Cognitive Neuroscience and NeuroimagingNetherlands Institute for NeuroscienceAmsterdamNetherlands
- Department of Experimental and Applied PsychologyVU UniversityAmsterdamNetherlands
| | - Jeroen C. W. Siero
- Spinoza Centre for NeuroimagingAmsterdamNetherlands
- Department of Computational Cognitive Neuroscience and NeuroimagingNetherlands Institute for NeuroscienceAmsterdamNetherlands
- Department of RadiologyUniversity Medical Center UtrechtUtrechtthe Netherlands
| | - Serge O. Dumoulin
- Spinoza Centre for NeuroimagingAmsterdamNetherlands
- Department of Computational Cognitive Neuroscience and NeuroimagingNetherlands Institute for NeuroscienceAmsterdamNetherlands
- Department of Experimental and Applied PsychologyVU UniversityAmsterdamNetherlands
- Department of Experimental PsychologyUtrecht UniversityUtrechtNetherlands
| | - Wietske van der Zwaag
- Spinoza Centre for NeuroimagingAmsterdamNetherlands
- Department of Computational Cognitive Neuroscience and NeuroimagingNetherlands Institute for NeuroscienceAmsterdamNetherlands
| | - Tomas Knapen
- Spinoza Centre for NeuroimagingAmsterdamNetherlands
- Department of Computational Cognitive Neuroscience and NeuroimagingNetherlands Institute for NeuroscienceAmsterdamNetherlands
- Department of Experimental and Applied PsychologyVU UniversityAmsterdamNetherlands
| |
Collapse
|
49
|
Schmidt T, Vannesjo SJ, Sommer S, Nagy Z. fMRI with whole-brain coverage, 75-ms temporal resolution and high SNR by combining HiHi reshuffling and multiband imaging. Magn Reson Imaging 2023; 103:48-53. [PMID: 37385353 DOI: 10.1016/j.mri.2023.06.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2023] [Revised: 06/26/2023] [Accepted: 06/26/2023] [Indexed: 07/01/2023]
Abstract
Increasing the temporal resolution of the blood‑oxygen level-dependent (BOLD) response is usually accompanied by a decrease in repetition time and therefore also a reduction of the magnetic resonance (MR) signal due to incomplete T1 relaxation and thus a loss of signal-to-noise ratio (SNR). A previous data reordering method can achieve higher temporal sampling rate without the loss of SNR but at the cost of increased scan time. In this proof-of-principle work, we show that combining HiHi reshuffling with multiband acceleration allows us to measure the in vivo BOLD response with a 75-ms sampling rate that is decoupled from the acquisition repetition time (here 1.5 s and hence higher SNR) while covering the entire forebrain with 60 2-mm slices in a ~ 35-min scan. We provide single-voxel time-courses of the BOLD responses in the primary visual and primary motor cortices in three fMRI experiments on a 7 T scanner - 1 male (scanned twice on different days for test-retest reproducibility) and 1 female participant.
Collapse
Affiliation(s)
- Tim Schmidt
- Laboratory for Social and Neural Systems Research, University of Zurich, Zurich, Switzerland; Institute for Biomedical Engineering, ETH Zurich and University of Zurich, Zurich, Switzerland.
| | - S Johanna Vannesjo
- Department of Physics, Norwegian University of Science and Technology, Trondheim, Norway
| | - Stefan Sommer
- Siemens Healthineers International AG, Zurich, Switzerland; Swiss Center for Musculoskeletal Imaging (SCMI), Balgrist Campus, Zurich, Switzerland; Advanced Clinical Imaging Technology (ACIT), Siemens Healthineers International AG, Lausanne, Switzerland
| | - Zoltán Nagy
- Laboratory for Social and Neural Systems Research, University of Zurich, Zurich, Switzerland
| |
Collapse
|
50
|
Kim H. Decoding force production of skeletal muscle from the female brain using functional near-infrared spectroscopy. BMC Res Notes 2023; 16:304. [PMID: 37915005 PMCID: PMC10619293 DOI: 10.1186/s13104-023-06588-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Accepted: 10/23/2023] [Indexed: 11/03/2023] Open
Abstract
OBJECTIVE Noninvasive neural decoding enables predicting motor output from neural activities without physically damaging the human body. A recent study demonstrated the applicability of functional near-infrared spectroscopy (fNIRS) to decode muscle force production from hemodynamic signals measured in the male brain. However, given the sex differences in cerebral blood flow and muscle physiology, whether the fNIRS approach can also be applied to the female brain remains elusive. Therefore, this study aimed to evaluate whether fNIRS can be used to identify the optimal cortical region and hemodynamic predictor to decode muscle force output in females. RESULTS Statistical group analysis for eight healthy female adults showed that the cortical region for wrist control was topologically dorsal to that for finger control over the primary sensorimotor cortex. This cortical area was maximally activated while the wrist flexor muscles were contracted to hold a load on the subject's palm, as was the case for males. However, the dynamics of oxyhemoglobin concentration measured from the most activated cortical area differed between females and males. The signal intensity during 100% maximal voluntary contraction and the signal increase rate at 50% maximal voluntary contraction was lower and faster in females. Eight predictors were used to characterize hemodynamic signals' amplitude and temporal variation in the female cortex. Unlike the case for males, only the trajectory predictors for the amplitude of oxyhemoglobin concentration change were strongly correlated with the strengths of force produced by the wrist flexor muscles, showing a linear relationship. These results suggest gender-specific hemodynamics must be considered for decoding low-level motor control with fNIRS in females.
Collapse
Affiliation(s)
- Hojeong Kim
- Division of Biotechnology, Institute of Convergence Research, DGIST, Daegu, Republic of Korea.
- Department of Interdisciplinary Studies, DGIST, Daegu, Republic of Korea.
| |
Collapse
|