1
|
Zimmermann M, Abbas Z, Sommer Y, Lewin A, Ramkiran S, Felder J, Worthoff WA, Oros-Peusquens AM, Yun SD, Shah NJ. QRAGE-Simultaneous multiparametric quantitative MRI of water content, T 1, T 2*, and magnetic susceptibility at ultrahigh field strength. Magn Reson Med 2025; 93:228-244. [PMID: 39219160 DOI: 10.1002/mrm.30272] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2024] [Revised: 07/26/2024] [Accepted: 08/10/2024] [Indexed: 09/04/2024]
Abstract
PURPOSE To introduce quantitative rapid gradient-echo (QRAGE), a novel approach for the simultaneous mapping of multiple quantitative MRI parameters, including water content, T1, T2*, and magnetic susceptibility at ultrahigh field strength. METHODS QRAGE leverages a newly developed multi-echo MPnRAGE sequence, facilitating the acquisition of 171 distinct contrast images across a range of TI and TE points. To maintain a short acquisition time, we introduce MIRAGE2, a novel model-based reconstruction method that exploits prior knowledge of temporal signal evolution, represented as damped complex exponentials. MIRAGE2 minimizes local Block-Hankel and Casorati matrices. Parameter maps are derived from the reconstructed contrast images through postprocessing steps. We validate QRAGE through extensive simulations, phantom studies, and in vivo experiments, demonstrating its capability for high-precision imaging. RESULTS In vivo brain measurements show the promising performance of QRAGE, with test-retest SDs and deviations from reference methods of < 0.8% for water content, < 17 ms for T1, and < 0.7 ms for T2*. QRAGE achieves whole-brain coverage at a 1-mm isotropic resolution in just 7 min and 15 s, comparable to the acquisition time of an MP2RAGE scan. In addition, QRAGE generates a contrast image akin to the UNI image produced by MP2RAGE. CONCLUSION QRAGE is a new, successful approach for simultaneously mapping multiple MR parameters at ultrahigh field.
Collapse
Affiliation(s)
- Markus Zimmermann
- Forschungszentrum Jülich, Institute of Neuroscience and Medicine-4, Jülich, Germany
| | - Zaheer Abbas
- Forschungszentrum Jülich, Institute of Neuroscience and Medicine-4, Jülich, Germany
| | - Yannic Sommer
- Forschungszentrum Jülich, Institute of Neuroscience and Medicine-4, Jülich, Germany
| | - Alexander Lewin
- Forschungszentrum Jülich, Institute of Neuroscience and Medicine-11, Jülich, Germany
| | - Shukti Ramkiran
- Forschungszentrum Jülich, Institute of Neuroscience and Medicine-4, Jülich, Germany
- Department of Psychiatry, Psychotherapy and Psychosomatics, RWTH Aachen University, Aachen, Germany
| | - Jörg Felder
- Forschungszentrum Jülich, Institute of Neuroscience and Medicine-4, Jülich, Germany
- RWTH Aachen University, Aachen, Germany
| | - Wieland A Worthoff
- Forschungszentrum Jülich, Institute of Neuroscience and Medicine-4, Jülich, Germany
| | | | - Seong Dae Yun
- Forschungszentrum Jülich, Institute of Neuroscience and Medicine-4, Jülich, Germany
| | - N Jon Shah
- Forschungszentrum Jülich, Institute of Neuroscience and Medicine-4, Jülich, Germany
- Forschungszentrum Jülich, Institute of Neuroscience and Medicine-11, Jülich, Germany
- JARA-BRAIN-Translational Medicine, Aachen, Germany
- Department of Neurology, RWTH Aachen University, Aachen, Germany
| |
Collapse
|
2
|
Zhou X, Daniel BL, Hargreaves BA, Lee PK. Distortion-free water-fat separated diffusion-weighted imaging using spatiotemporal joint reconstruction. Magn Reson Med 2024; 92:2343-2357. [PMID: 39051729 DOI: 10.1002/mrm.30221] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2024] [Revised: 06/03/2024] [Accepted: 06/25/2024] [Indexed: 07/27/2024]
Abstract
PURPOSE Diffusion-weighted imaging (DWI) suffers from geometric distortion and chemical shift artifacts due to the commonly used Echo Planar Imaging (EPI) trajectory. Even with fat suppression in DWI, severe B0 and B1 variations can result in residual fat, which becomes both a source of image artifacts and a confounding factor in diffusion-weighted contrast in distinguishing benign and malignant tissues. This work presents a method for acquiring distortion-free diffusion-weighted images using spatiotemporal acquisition and joint reconstruction. Water-fat separation is performed by chemical-shift encoding. METHODS Spatiotemporal acquisition is employed to obtain distortion-free images at a series of echo times. Chemical-shift encoding is used for water-fat separation. Reconstruction and separation are performed jointly in the spat-spectral domain. To address the shot-to-shot motion-induced phase in DWI, an Fast Spin Echo (FSE)-based phase navigator is incorporated into the sequence to obtain distortion-free phase information. The proposed method was validated in phantoms and in vivo for the brain, head and neck, and breast. RESULTS The proposed method enables the acquisition of distortion-free diffusion-weighted images in the presence of B0 field inhomogenieties commonly observed in the body. Water and fat components are separated with no obvious spectral leakage artifacts. The estimated Apparent Diffusion Coefficient (ADC) is comparable to that of multishot DW-EPI. CONCLUSION Distortion-free, water-fat separated diffusion-weighted images in body can be obtained through the utilization of spatiotemporal acquisition and joint reconstruction methods.
Collapse
Affiliation(s)
- Xuetong Zhou
- Department of Radiology, Stanford University, Stanford, California, USA
- Department of Bioengineering, Stanford University, Stanford, California, USA
| | - Bruce L Daniel
- Department of Radiology, Stanford University, Stanford, California, USA
- Department of Bioengineering, Stanford University, Stanford, California, USA
| | - Brian A Hargreaves
- Department of Radiology, Stanford University, Stanford, California, USA
- Department of Bioengineering, Stanford University, Stanford, California, USA
- Department of Electrical Engineering, Stanford University, Stanford, California, USA
| | - Philip K Lee
- Department of Radiology, Stanford University, Stanford, California, USA
| |
Collapse
|
3
|
Gao J, Gong Y, Tang X, Chen H, Chen Z, Shen Y, Zhou Z, Emu Y, Aburas A, Jin W, Hua S, Hu C. Accelerated Cartesian cardiac T2 mapping based on a calibrationless locally low-rank tensor constraint. Quant Imaging Med Surg 2024; 14:7654-7670. [PMID: 39429619 PMCID: PMC11485370 DOI: 10.21037/qims-24-740] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2024] [Accepted: 08/12/2024] [Indexed: 10/22/2024]
Abstract
Background Cardiac T2 mapping is a valuable tool for diagnosing myocardial edema, inflammation, and infiltration, yet its spatial resolution is limited by the single-shot balanced steady-state free precession acquisition and duration of the cardiac quiescent period, which may reduce sensitivity in detecting focal lesions in the myocardium. To improve spatial resolution without extending the acquisition window, this study examined a novel accelerated Cartesian cardiac T2 mapping technique. Methods We introduce a novel improved-resolution cardiac T2 mapping approach leveraging a calibrationless space-contrast-coil locally low-rank tensor (SCC-LLRT)-constrained reconstruction algorithm in conjunction with Cartesian undersampling trajectory. The method was validated with phantom imaging and in vivo imaging that involved 13 healthy participants and 20 patients. The SCC-LLRT algorithm was compared with a conventional locally low-rank (LLR)-constrained algorithm and a nonlinear inversion (NLINV) reconstruction algorithm. The improved-resolution T2 mapping (1.4 mm × 1.4 mm) was compared globally and regionally with the regular-resolution T2 mapping (2.3 mm × 1.9 mm) according to the 16-segment model of the American Heart Association. The agreement between the improved-resolution and regular-resolution T2 mappings was evaluated by linear regression and Bland-Altman analyses. Image quality was scored by two experienced reviewers on a five-point scale (1, worst; 5, best). Results In healthy participants, SCC-LLRT significantly reduced artifacts (4.50±0.39) compared with LLR (2.31±0.60; P<0.001) and NLINV (3.65±0.56; P<0.01), suppressed noise (4.12±0.35) compared with NLINV (2.65±0.50; P<0.001), and improved the overall image quality (4.38±0.40) compared with LLR (2.54±0.41; P<0.001) and NLINV (3.04±0.50; P<0.001). Compared with the regular-resolution T2 mapping, the proposed method significantly improved the sharpness of myocardial boundaries (4.46±0.60 vs. 3.04±0.50; P<0.001) and the conspicuity of papillary muscles and fine structures (4.46±0.63 vs. 2.65±0.30; P<0.001). Myocardial T2 values obtained with the proposed method correlated significantly with those from regular-resolution T2 mapping in both healthy participants (r=0.79; P<0.01) and patients (r=0.94; P<0.001). Conclusions The proposed SCC-LLRT-constrained reconstruction algorithm in conjunction with Cartesian undersampling pattern achieved improved-resolution cardiac T2 mapping of comparable accuracy, precision, and scan-rescan reproducibility compared with the regular-resolution T2 mapping. The higher resolution improved the sharpness of myocardial borders and the conspicuity of image fine details, which may increase diagnostic confidence in cardiac T2 mapping for detecting small lesions.
Collapse
Affiliation(s)
- Juan Gao
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Yiwen Gong
- Department of Cardiovascular Medicine, Heart Failure Center, Ruijin Hospital Lu Wan Branch, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Xin Tang
- Shanghai United Imaging Healthcare Co., Ltd., Shanghai, China
| | - Haiyang Chen
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Zhuo Chen
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Yiwen Shen
- Department of Cardiovascular Medicine, Heart Failure Center, Ruijin Hospital Lu Wan Branch, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Zhongjie Zhou
- Department of Cardiovascular Medicine, Heart Failure Center, Ruijin Hospital Lu Wan Branch, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Yixin Emu
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Ahmed Aburas
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Wei Jin
- Department of Cardiovascular Medicine, Heart Failure Center, Ruijin Hospital Lu Wan Branch, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Sha Hua
- Department of Cardiovascular Medicine, Heart Failure Center, Ruijin Hospital Lu Wan Branch, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Chenxi Hu
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
4
|
Rowley CD, Nelson MC, Campbell JSW, Leppert IR, Pike GB, Tardif CL. Fast magnetization transfer saturation imaging of the brain using MP2RAGE T 1 mapping. Magn Reson Med 2024; 92:1540-1555. [PMID: 38703017 DOI: 10.1002/mrm.30143] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2023] [Revised: 03/26/2024] [Accepted: 04/17/2024] [Indexed: 05/06/2024]
Abstract
PURPOSE Magnetization transfer saturation (MTsat) mapping is commonly used to examine the macromolecular content of brain tissue. This study compared variable flip angle (VFA) T1 mapping against compressed-sensing MP2RAGE (csMP2RAGE) T1 mapping for accelerating MTsat imaging. METHODS VFA, MP2RAGE, and csMP2RAGE were compared against inversion-recovery T1 in an aqueous phantom at 3 T. The same 1-mm VFA, MP2RAGE, and csMP2RAGE protocols were acquired in 4 healthy subjects to compare T1 and MTsat. Bloch-McConnell simulations were used to investigate differences between the phantom and in vivo T1 results. Ten healthy controls were imaged twice with the csMP2RAGE MTsat protocol to quantify repeatability. RESULTS The MP2RAGE and csMP2RAGE protocols were 13.7% and 32.4% faster than the VFA protocol, respectively. At these scan times, all approaches provided strong repeatability and accurate T1 times (< 5% difference) in the phantom, but T1 accuracy was more impacted by T2 for VFA than for MP2RAGE. In vivo, VFA estimated longer T1 times than MP2RAGE and csMP2RAGE. Simulations suggest that the differences in the T1 measured using VFA, MP2RAGE, and inversion recovery could be explained by the magnetization-transfer effects. In the test-retest experiment, we found that the csMP2RAGE has a minimum detectable change of 2.3% for T1 mapping and 7.8% for MTsat imaging. CONCLUSIONS We demonstrated that MP2RAGE can be used in place of VFA T1 mapping in an MTsat protocol. Furthermore, a shorter scan time and high repeatability can be achieved using the csMP2RAGE sequence.
Collapse
Affiliation(s)
- Christopher D Rowley
- McConnell Brain Imaging Center, Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada
- Department of Neurology and Neurosurgery, McGill University, Montreal, Quebec, Canada
- Department of Physics and Astronomy, McMaster University, Hamilton, Ontario, Canada
| | - Mark C Nelson
- McConnell Brain Imaging Center, Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada
| | - Jennifer S W Campbell
- McConnell Brain Imaging Center, Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada
| | - Ilana R Leppert
- McConnell Brain Imaging Center, Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada
| | - G Bruce Pike
- Department of Radiology and Clinical Neuroscience, Hotchkiss Brain Institute, University of Calgary, Calgary, Alberta, Canada
| | - Christine L Tardif
- McConnell Brain Imaging Center, Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada
- Department of Neurology and Neurosurgery, McGill University, Montreal, Quebec, Canada
- Department of Biomedical Engineering, McGill University, Montreal, Quebec, Canada
| |
Collapse
|
5
|
Mao A, Flassbeck S, Assländer J. Bias-reduced neural networks for parameter estimation in quantitative MRI. Magn Reson Med 2024; 92:1638-1648. [PMID: 38703042 DOI: 10.1002/mrm.30135] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Revised: 04/09/2024] [Accepted: 04/11/2024] [Indexed: 05/06/2024]
Abstract
PURPOSE To develop neural network (NN)-based quantitative MRI parameter estimators with minimal bias and a variance close to the Cramér-Rao bound. THEORY AND METHODS We generalize the mean squared error loss to control the bias and variance of the NN's estimates, which involves averaging over multiple noise realizations of the same measurements during training. Bias and variance properties of the resulting NNs are studied for two neuroimaging applications. RESULTS In simulations, the proposed strategy reduces the estimates' bias throughout parameter space and achieves a variance close to the Cramér-Rao bound. In vivo, we observe good concordance between parameter maps estimated with the proposed NNs and traditional estimators, such as nonlinear least-squares fitting, while state-of-the-art NNs show larger deviations. CONCLUSION The proposed NNs have greatly reduced bias compared to those trained using the mean squared error and offer significantly improved computational efficiency over traditional estimators with comparable or better accuracy.
Collapse
Affiliation(s)
- Andrew Mao
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA
- Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA
- Vilcek Institute of Graduate Biomedical Sciences, New York University Grossman School of Medicine, New York, New York, USA
| | - Sebastian Flassbeck
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA
- Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA
| | - Jakob Assländer
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA
- Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA
| |
Collapse
|
6
|
Li H, Priest AN, Horvat-Menih I, Huang Y, Li S, Stewart GD, Mendichovszky IA, Francis ST, Gallagher FA. Fast and High-Resolution T 2 Mapping Based on Echo Merging Plus k-t Undersampling with Reduced Refocusing Flip Angles (TEMPURA) as Methods for Human Renal MRI. Magn Reson Med 2024; 92:1138-1148. [PMID: 38730565 DOI: 10.1002/mrm.30115] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2023] [Revised: 03/05/2024] [Accepted: 03/29/2024] [Indexed: 05/13/2024]
Abstract
PURPOSE To develop a highly accelerated multi-echo spin-echo method, TEMPURA, for reducing the acquisition time and/or increasing spatial resolution for kidney T2 mapping. METHODS TEMPURA merges several adjacent echoes into one k-space by either combining independent echoes or sharing one echo between k-spaces. The combined k-space is reconstructed based on compressed sensing theory. Reduced flip angles are used for the refocusing pulses, and the extended phase graph algorithm is used to correct the effects of indirect echoes. Two sequences were developed: a fast breath-hold sequence; and a high-resolution sequence. The performance was evaluated prospectively on a phantom, 16 healthy subjects, and two patients with different types of renal tumors. RESULTS The fast TEMPURA method reduced the acquisition time from 3-5 min to one breath-hold (18 s). Phantom measurements showed that fast TEMPURA had a mean absolute percentage error (MAPE) of 8.2%, which was comparable to a standardized respiratory-triggered sequence (7.4%), but much lower than a sequence accelerated by purely k-t undersampling (21.8%). High-resolution TEMPURA reduced the in-plane voxel size from 3 × 3 to 1 × 1 mm2, resulting in improved visualization of the detailed anatomical structure. In vivo T2 measurements demonstrated good agreement (fast: MAPE = 1.3%-2.5%; high-resolution: MAPE = 2.8%-3.3%) and high correlation coefficients (fast: R = 0.85-0.98; high-resolution: 0.82-0.96) with the standardized method, outperforming k-t undersampling alone (MAPE = 3.3-4.5%, R = 0.57-0.59). CONCLUSION TEMPURA provides fast and high-resolution renal T2 measurements. It has the potential to improve clinical throughput and delineate intratumoral heterogeneity and tissue habitats at unprecedented spatial resolution.
Collapse
Affiliation(s)
- Hao Li
- Institute of Science and Technology for Brain-Inspired Intelligence, Fudan University, Shanghai, China
- Department of Radiology, University of Cambridge, Cambridge, UK
| | - Andrew N Priest
- Department of Radiology, University of Cambridge, Cambridge, UK
- Department of Radiology, Cambridge University Hospitals NHS Foundation Trust, Addenbrooke's Hospital, Cambridge, UK
| | | | - Yuan Huang
- Department of Radiology, University of Cambridge, Cambridge, UK
- EPSRC Cambridge Mathematics of Information in Healthcare Hub, University of Cambridge, Cambridge, UK
| | - Shaohang Li
- Institute of Science and Technology for Brain-Inspired Intelligence, Fudan University, Shanghai, China
| | - Grant D Stewart
- Department of Surgery, Cambridge University Hospitals NHS Foundation Trust, Addenbrooke's Hospital, Cambridge, UK
| | - Iosif A Mendichovszky
- Department of Radiology, University of Cambridge, Cambridge, UK
- Department of Radiology, Cambridge University Hospitals NHS Foundation Trust, Addenbrooke's Hospital, Cambridge, UK
| | - Susan T Francis
- Sir Peter Mansfield Imaging Centre, University of Nottingham, Nottingham, UK
| | - Ferdia A Gallagher
- Department of Radiology, University of Cambridge, Cambridge, UK
- Department of Radiology, Cambridge University Hospitals NHS Foundation Trust, Addenbrooke's Hospital, Cambridge, UK
| |
Collapse
|
7
|
Chen J, Xia D, Huang C, Shanbhogue K, Chandarana H, Feng L. Free-breathing time-resolved 4D MRI with improved T1-weighting contrast. NMR IN BIOMEDICINE 2024:e5247. [PMID: 39183645 DOI: 10.1002/nbm.5247] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/21/2024] [Revised: 08/06/2024] [Accepted: 08/08/2024] [Indexed: 08/27/2024]
Abstract
This work proposes MP-Grasp4D (magnetization-prepared golden-angle radial sparse parallel 4D) MRI, a free-breathing, inversion recovery (IR)-prepared, time-resolved 4D MRI technique with improved T1-weighted contrast. MP-Grasp4D MRI acquisition incorporates IR preparation into a radial gradient echo sequence. MP-Grasp4D employs a golden-angle navi-stack-of-stars sampling scheme, where imaging data of rotating radial stacks and navigator stacks (acquired at a consistent rotation angle) are alternately acquired. The navigator stacks are used to estimate a temporal basis for low-rank subspace-constrained reconstruction. This allows for the simultaneous capture of both IR-induced contrast changes and respiratory motion. One temporal frame of the imaging volume in MP-Grasp4D MRI is reconstructed from a single stack and an adjacent navigator stack on average, resulting in a nominal temporal resolution of 0.16 seconds per volume. Images corresponding to the optimal inversion time (TI) can be retrospectively selected for providing the best image contrast. Reader studies were conducted to assess the performance of MP-Grasp4D MRI in liver imaging across 30 subjects in comparison with standard Grasp4D MRI without IR preparation. MP-Grasp4D MRI received significantly higher scores (P < 0.05) than Grasp4D in all assessment categories. There was a moderate to almost perfect agreement (kappa coefficient from 0.42 to 0.9) between the two readers for image quality assessment. When the scan time is reduced, MP-Grasp4D MRI preserves image contrast and quality, demonstrating additional acceleration capability. MP-Grasp4D MRI improves T1-weighted contrast for free-breathing time-resolved 4D MRI and eliminates the need for explicit motion compensation. This method is expected to be valuable in different MRI applications such as MR-guided radiotherapy.
Collapse
Affiliation(s)
- Jingjia Chen
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA
- Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA
| | - Ding Xia
- Icahn School of Medicine at Mount Sinai, Biomedical Engineering and Imaging Institute, New York, New York, USA
| | - Chenchan Huang
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA
- Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA
| | - Krishna Shanbhogue
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA
- Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA
| | - Hersh Chandarana
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA
- Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA
| | - Li Feng
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA
- Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA
| |
Collapse
|
8
|
Feng W, Ding Z, Chen Q, She H, Du YP. Whole brain multiparametric mapping in two minutes using a dual-flip-angle stack-of-stars blipped multi-gradient-echo acquisition. Neuroimage 2024; 297:120689. [PMID: 38880311 DOI: 10.1016/j.neuroimage.2024.120689] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2023] [Revised: 06/11/2024] [Accepted: 06/14/2024] [Indexed: 06/18/2024] Open
Abstract
A new MRI technique is presented for three-dimensional fast simultaneous whole brain mapping of myelin water fraction (MWF), T1, proton density (PD), R2*, magnetic susceptibility (QSM), and B1 transmit field (B1+). Phantom and human (N = 9) datasets were acquired using a dual-flip-angle blipped multi-gradient-echo (DFA-mGRE) sequence with a stack-of-stars (SOS) trajectory. Images were reconstructed using a subspace-based algorithm with a locally low-rank constraint. A novel joint-sparsity-constrained multicomponent T2*-T1 spectrum estimation (JMSE) algorithm is proposed to correct for the T1 saturation effect and B1+/B1- inhomogeneities in the quantification of MWF. A tissue-prior-based B1+ estimation algorithm was adapted for B1 correction in the mapping of T1 and PD. In the phantom study, measurements obtained at an acceleration factor (R) of 12 using prospectively under-sampled SOS showed good consistency (R2 > 0.997) with Cartesian reference for R2*/T1app/M0app. In the in vivo study, results of retrospectively under-sampled SOS with R = 6, 12, 18, showed good quality (structure similarity index measure > 0.95) compared with those of fully-sampled SOS. Besides, results of prospectively under-sampled SOS with R = 12 showed good consistency (intraclass correlation coefficient > 0.91) with Cartesian reference for T1/PD/B1+/MWF/QSM/R2*, and good reproducibility (coefficient of variation < 7.0 %) in the test-retest analysis for T1/PD/B1+/MWF/R2*. This study has demonstrated the feasibility of simultaneous whole brain multiparametric mapping with a two-minute scan using the DFA-mGRE SOS sequence, which may overcome a major obstacle for neurological applications of multiparametric MRI.
Collapse
Affiliation(s)
- Wenlong Feng
- National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Zekang Ding
- National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Quan Chen
- National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Huajun She
- National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.
| | - Yiping P Du
- National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.
| |
Collapse
|
9
|
Gao J, Gong Y, Emu Y, Chen Z, Chen H, Yang F, Ding Z, Hua S, Jin W, Hu C. High Spatial-Resolution and Acquisition-Efficiency Cardiac MR T1 Mapping Based on Radial bSSFP and a Low-Rank Tensor Constraint. J Magn Reson Imaging 2024. [PMID: 39143028 DOI: 10.1002/jmri.29564] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2024] [Revised: 07/29/2024] [Accepted: 07/29/2024] [Indexed: 08/16/2024] Open
Abstract
BACKGROUND Cardiac T1 mapping is valuable for evaluating myocardial fibrosis, yet its resolution and acquisition efficiency are limited, potentially obscuring visualization of small pathologies. PURPOSE To develop a technique for high-resolution cardiac T1 mapping with a less-than-100-millisecond acquisition window based on radial MOdified Look-Locker Inversion recovery (MOLLI) and a calibrationless space-contrast-coil locally low-rank tensor (SCC-LLRT) constrained reconstruction. STUDY TYPE Prospective. SUBJECTS/PHANTOM Sixteen healthy subjects (age 25 ± 3 years, 44% females) and 12 patients with suspected cardiomyopathy (age 57 ± 15 years, 42% females), NiCl2-agar phantom. FIELD STRENGTH/SEQUENCE 3-T, standard MOLLI, radial MOLLI, inversion-recovery spin-echo, late gadolinium enhancement. ASSESSMENT SCC-LLRT was compared to a conventional locally low-rank (LLR) method through simulations using Normalized Root-Mean-Square Error (NRMSE) and Structural Similarity Index Measure (SSIM). Radial MOLLI was compared to standard MOLLI across phantom, healthy subjects, and patients. Three independent readers subjectively evaluated the quality of T1 maps using a 5-point scale (5 = best). STATISTICAL TESTS Paired t-test, Wilcoxon signed-rank test, intraclass correlation coefficient analysis, linear regression, Bland-Altman analysis. P < 0.05 was considered statistically significant. RESULTS In simulations, SCC-LLRT demonstrated a significant improvement in NRMSE and SSIM compared to LLR. In phantom, both radial MOLLI and standard MOLLI provided consistent T1 estimates across different heart rates. In healthy subjects, radial MOLLI exhibited a significantly lower mean T1 (1115 ± 39 msec vs. 1155 ± 36 msec), similar T1 SD (74 ± 14 msec vs. 67 ± 23 msec, P = 0.20), and similar T1 reproducibility (28 ± 18 msec vs. 22 ± 15 msec, P = 0.34) compared to standard MOLLI. In patients, the proposed method significantly improved the sharpness of myocardial boundaries (4.50 ± 0.65 vs. 3.25 ± 0.43), the conspicuity of papillary muscles and fine structures (4.33 ± 0.74 vs. 3.33 ± 0.47), and artifacts (4.75 ± 0.43 vs. 3.83 ± 0.55). The reconstruction time for a single slice was 5.2 hours. DATA CONCLUSION The proposed method enables high-resolution cardiac T1 mapping with a short acquisition window and improved image quality. EVIDENCE LEVEL 1 TECHNICAL EFFICACY: Stage 1.
Collapse
Affiliation(s)
- Juan Gao
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Yiwen Gong
- Department of Cardiovascular Medicine, Heart Failure Center, Ruijin Hospital and Ruijin Hospital Lu Wan Branch, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Yixin Emu
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Zhuo Chen
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Haiyang Chen
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Fan Yang
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Zekang Ding
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Sha Hua
- Department of Cardiovascular Medicine, Heart Failure Center, Ruijin Hospital and Ruijin Hospital Lu Wan Branch, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Wei Jin
- Department of Cardiovascular Medicine, Heart Failure Center, Ruijin Hospital and Ruijin Hospital Lu Wan Branch, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Chenxi Hu
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
10
|
Heydari A, Ahmadi A, Kim TH, Bilgic B. Fast Whole-Brain MR Multi-Parametric Mapping with Scan-Specific Self-Supervised Networks. ARXIV 2024:arXiv:2408.02988v1. [PMID: 39148933 PMCID: PMC11326419] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Download PDF] [Subscribe] [Scholar Register] [Indexed: 08/17/2024]
Abstract
Quantification of tissue parameters using MRI is emerging as a powerful tool in clinical diagnosis and research studies. The need for multiple long scans with different acquisition parameters prohibits quantitative MRI from reaching widespread adoption in routine clinical and research exams. Accelerated parameter mapping techniques leverage parallel imaging, signal modelling and deep learning to offer more practical quantitative MRI acquisitions. However, the achievable acceleration and the quality of maps are often limited. Joint MAPLE is a recent state-of-the-art multi-parametric and scan-specific parameter mapping technique with promising performance at high acceleration rates. It synergistically combines parallel imaging, model-based and machine learning approaches for joint mapping ofT 1 , T 2 * , proton density and the field inhomogeneity. However, Joint MAPLE suffers from prohibitively long reconstruction time to estimate the maps from a multi-echo, multi-flip angle (MEMFA) dataset at high resolution in a scan-specific manner. In this work, we propose a faster version of Joint MAPLE which retains the mapping performance of the original version. Coil compression, random slice selection, parameter-specific learning rates and transfer learning are synergistically combined in the proposed framework. It speeds-up the reconstruction time up to 700 times than the original version and processes a whole-brain MEMFA dataset in 21 minutes on average, which originally requires ~260 hours for Joint MAPLE. The mapping performance of the proposed framework is ~2-fold better than the standard and the state-of-the-art evaluated reconstruction techniques on average in terms of the root mean squared error.
Collapse
Affiliation(s)
- Amir Heydari
- Department of Industrial Engineering and Management Systems, Amirkabir University of Technology, Tehran, Iran
| | - Abbas Ahmadi
- Department of Industrial Engineering and Management Systems, Amirkabir University of Technology, Tehran, Iran
| | - Tae Hyung Kim
- Department of Computer Engineering, Hongik University, Seoul, Korea
| | - Berkin Bilgic
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, United States
- Radiology, Harvard Medical School, Boston, MA, United States
| |
Collapse
|
11
|
Tang X, Gao J, Aburas A, Wu D, Chen Z, Chen H, Hu C. Accelerated multi-b-value multi-shot diffusion-weighted imaging based on EPI with keyhole and a low-rank tensor constraint. Magn Reson Imaging 2024; 110:138-148. [PMID: 38641211 DOI: 10.1016/j.mri.2024.04.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2024] [Revised: 04/08/2024] [Accepted: 04/10/2024] [Indexed: 04/21/2024]
Abstract
PURPOSE Multi-Shot (MS) Echo-Planar Imaging (EPI) may improve the in-plane resolution of multi-b-value DWI, yet it also considerably increases the scan time. Here we explored the combination of EPI with Keyhole (EPIK) and a calibrationless reconstruction algorithm for acceleration of multi-b-value MS-DWI. METHODS We firstly analyzed the impact of nonuniform phase accrual in EPIK on the reconstructed image. Based on insights gained from the analysis, we developed a calibrationless reconstruction algorithm based on a Space-Contrast-Coil Locally Low-Rank Tensor (SCC-LLRT) constraint for reconstruction of EPIK-acquired data. We compared the algorithm with a modified SPatial-Angular Locally Low-Rank (SPA-LLR) algorithm through simulations, phantoms, and in vivo study. We then compared EPIK with uniformly undersampled EPI for accelerating multi-b-value DWI in 6 healthy subjects. RESULTS Through theoretical derivations, we found that the reconstruction of EPIK with a SENSE-encoding-based algorithm, such as SPA-LLR, may cause additional aliasing artifacts due to the frequency-dependent distortion of the coil sensitivity. Results from simulations, phantoms, and in vivo study verified the theoretical finding by showing that the calibrationless SCC-LLRT algorithm reduced aliasing artifacts compared with SPA-LLR. Finally, EPIK with SCC-LLRT substantially reduced the ghosting artifacts compared with uniform undersampled multi-b-value DWI, decreasing the fitting errors in ADC (0.05 ± 0.01 vs 0.10 ± 0.01, P < 0.001) and IVIM mapping (0.026 ± 0.004 vs 0.06 ± 0.006, P < 0.001). CONCLUSION The SCC-LLRT algorithm reduced the aliasing artifacts of EPIK by using a calibrationless modeling of the multi-coil data. The dense sampling of k-space center offers EPIK a potential to improve image quality for acceleration of multi-b-value MS-DWI.
Collapse
Affiliation(s)
- Xin Tang
- National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China; United Imaging Healthcare Co. Ltd, Shanghai, China
| | - Juan Gao
- National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Ahmed Aburas
- National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Dan Wu
- Department of Biomedical Engineering, College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, Zhejiang, China
| | - Zhuo Chen
- National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Hao Chen
- National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Chenxi Hu
- National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.
| |
Collapse
|
12
|
Bian W, Jang A, Liu F. Improving quantitative MRI using self-supervised deep learning with model reinforcement: Demonstration for rapid T1 mapping. Magn Reson Med 2024; 92:98-111. [PMID: 38342980 PMCID: PMC11055673 DOI: 10.1002/mrm.30045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2023] [Revised: 12/21/2023] [Accepted: 01/23/2024] [Indexed: 02/13/2024]
Abstract
PURPOSE This paper proposes a novel self-supervised learning framework that uses model reinforcement, REference-free LAtent map eXtraction with MOdel REinforcement (RELAX-MORE), for accelerated quantitative MRI (qMRI) reconstruction. The proposed method uses an optimization algorithm to unroll an iterative model-based qMRI reconstruction into a deep learning framework, enabling accelerated MR parameter maps that are highly accurate and robust. METHODS Unlike conventional deep learning methods which require large amounts of training data, RELAX-MORE is a subject-specific method that can be trained on single-subject data through self-supervised learning, making it accessible and practically applicable to many qMRI studies. Using quantitativeT 1 $$ {\mathrm{T}}_1 $$ mapping as an example, the proposed method was applied to the brain, knee and phantom data. RESULTS The proposed method generates high-quality MR parameter maps that correct for image artifacts, removes noise, and recovers image features in regions of imperfect image conditions. Compared with other state-of-the-art conventional and deep learning methods, RELAX-MORE significantly improves efficiency, accuracy, robustness, and generalizability for rapid MR parameter mapping. CONCLUSION This work demonstrates the feasibility of a new self-supervised learning method for rapid MR parameter mapping, that is readily adaptable to the clinical translation of qMRI.
Collapse
Affiliation(s)
- Wanyu Bian
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
| | - Albert Jang
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
| | - Fang Liu
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|
13
|
Guan Y, Li Y, Ke Z, Peng X, Liu R, Li Y, Du YP, Liang ZP. Learning-Assisted Fast Determination of Regularization Parameter in Constrained Image Reconstruction. IEEE Trans Biomed Eng 2024; 71:2253-2264. [PMID: 38376982 DOI: 10.1109/tbme.2024.3367762] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/22/2024]
Abstract
OBJECTIVE To leverage machine learning (ML) for fast selection of optimal regularization parameter in constrained image reconstruction. METHODS Constrained image reconstruction is often formulated as a regularization problem and selecting a good regularization parameter value is an essential step. We solved this problem using an ML-based approach by leveraging the finding that for a specific constrained reconstruction problem defined for a fixed class of image functions, the optimal regularization parameter value is weakly subject-dependent and the dependence can be captured using few experimental data. The proposed method has four key steps: a) solution of a given constrained reconstruction problem for a few (say, 3) pre-selected regularization parameter values, b) extraction of multiple approximated quality metrics from the initial reconstructions, c) predicting the true quality metrics values from the approximated values using pre-trained neural networks, and d) determination of the optimal regularization parameter by fusing the predicted quality metrics. RESULTS The effectiveness of the proposed method was demonstrated in two constrained reconstruction problems. Compared with L-curve-based method, the proposed method determined the regularization parameters much faster and produced substantially improved reconstructions. Our method also outperformed state-of-the-art learning-based methods when trained with limited experimental data. CONCLUSION This paper demonstrates the feasibility and improved reconstruction quality by using machine learning to determine the regularization parameter in constrained reconstruction. SIGNIFICANCE The proposed method substantially reduces the computational burden of the traditional methods (e.g., L-curve) or relaxes the requirement of large training data by modern learning-based methods, thus enhancing the practical utility of constrained reconstruction.
Collapse
|
14
|
Elsaid NMH, Dispenza NL, Hu C, Peters DC, Constable RT, Tagare HD, Galiana G. Constrained alternating minimization for parameter mapping (CAMP). Magn Reson Imaging 2024; 110:176-183. [PMID: 38657714 PMCID: PMC11193090 DOI: 10.1016/j.mri.2024.04.029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2024] [Revised: 04/03/2024] [Accepted: 04/22/2024] [Indexed: 04/26/2024]
Abstract
OBJECTIVE To improve image quality in highly accelerated parameter mapping by incorporating a linear constraint that relates consecutive images. APPROACH In multi-echo T1 or T2 mapping, scan time is often shortened by acquiring undersampled but complementary measures of k-space at each TE or TI. However, residual undersampling artifacts from the individual images can then degrade the quality of the final parameter maps. In this work, a new reconstruction method, dubbed Constrained Alternating Minimization for Parameter mapping (CAMP), is introduced. This method simultaneously extracts T2 or T1* maps in addition to an image for each TE or TI from accelerated datasets, leveraging the constraints of the decay to improve the reconstructed image quality. The model enforces exponential decay through a linear constraint, resulting in a biconvex objective function that lends itself to alternating minimization. The method was tested in four in vivo volunteer experiments and validated in phantom studies and healthy subjects, using T2 and T1 mapping, with accelerations of up to 12. MAIN RESULTS CAMP is demonstrated for accelerated radial and Cartesian acquisitions in T2 and T1 mapping. The method is even applied to generate an entire T2 weighted image series from a single TSE dataset, despite the blockwise k-space sampling at each echo time. Experimental undersampled phantom and in vivo results processed with CAMP exhibit reduced artifacts without introducing bias. SIGNIFICANCE For a wide array of applications, CAMP linearizes the model cost function without sacrificing model accuracy so that the well-conditioned and highly efficient reconstruction algorithm improves the image quality of accelerated parameter maps.
Collapse
Affiliation(s)
- Nahla M H Elsaid
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, USA
| | - Nadine L Dispenza
- Siemens Healthcare GmbH Allee am Röthelheimpark, 91052 Erlangen, Deutschland
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
| | - Chenxi Hu
- The Institute of Medical Imaging Technology, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Dana C Peters
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, USA
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
| | - R Todd Constable
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, USA
- Department of Neurosurgery, Yale University, New Haven, CT, 06520, USA
| | - Hemant D Tagare
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, USA
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
| | - Gigi Galiana
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, USA
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
| |
Collapse
|
15
|
Zhao R, Peng X, Kelkar VA, Anastasio MA, Lam F. High-Dimensional MR Reconstruction Integrating Subspace and Adaptive Generative Models. IEEE Trans Biomed Eng 2024; 71:1969-1979. [PMID: 38265912 PMCID: PMC11105985 DOI: 10.1109/tbme.2024.3358223] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2024]
Abstract
OBJECTIVE To develop a new method that integrates subspace and generative image models for high-dimensional MR image reconstruction. METHODS We proposed a formulation that synergizes a low-dimensional subspace model of high-dimensional images, an adaptive generative image prior serving as spatial constraints on the sequence of "contrast-weighted" images or spatial coefficients of the subspace model, and a conventional sparsity regularization. A special pretraining plus subject-specific network adaptation strategy was proposed to construct an accurate generative-network-based representation for images with varying contrasts. An iterative algorithm was introduced to jointly update the subspace coefficients and the multi-resolution latent space of the generative image model that leveraged an recently proposed intermediate layer optimization technique for network inversion. RESULTS We evaluated the utility of the proposed method for two high-dimensional imaging applications: accelerated MR parameter mapping and high-resolution MR spectroscopic imaging. Improved performance over state-of-the-art subspace-based methods was demonstrated in both cases. CONCLUSION The proposed method provided a new way to address high-dimensional MR image reconstruction problems by incorporating an adaptive generative model as a data-driven spatial prior for constraining subspace reconstruction. SIGNIFICANCE Our work demonstrated the potential of integrating data-driven and adaptive generative priors with canonical low-dimensional modeling for high-dimensional imaging problems.
Collapse
|
16
|
Jun Y, Arefeen Y, Cho J, Fujita S, Wang X, Ellen Grant P, Gagoski B, Jaimes C, Gee MS, Bilgic B. Zero-DeepSub: Zero-shot deep subspace reconstruction for rapid multiparametric quantitative MRI using 3D-QALAS. Magn Reson Med 2024; 91:2459-2482. [PMID: 38282270 PMCID: PMC11005062 DOI: 10.1002/mrm.30018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Revised: 12/15/2023] [Accepted: 01/06/2024] [Indexed: 01/30/2024]
Abstract
PURPOSE To develop and evaluate methods for (1) reconstructing 3D-quantification using an interleaved Look-Locker acquisition sequence with T2 preparation pulse (3D-QALAS) time-series images using a low-rank subspace method, which enables accurate and rapid T1 and T2 mapping, and (2) improving the fidelity of subspace QALAS by combining scan-specific deep-learning-based reconstruction and subspace modeling. THEORY AND METHODS A low-rank subspace method for 3D-QALAS (i.e., subspace QALAS) and zero-shot deep-learning subspace method (i.e., Zero-DeepSub) were proposed for rapid and high fidelity T1 and T2 mapping and time-resolved imaging using 3D-QALAS. Using an ISMRM/NIST system phantom, the accuracy and reproducibility of the T1 and T2 maps estimated using the proposed methods were evaluated by comparing them with reference techniques. The reconstruction performance of the proposed subspace QALAS using Zero-DeepSub was evaluated in vivo and compared with conventional QALAS at high reduction factors of up to nine-fold. RESULTS Phantom experiments showed that subspace QALAS had good linearity with respect to the reference methods while reducing biases and improving precision compared to conventional QALAS, especially for T2 maps. Moreover, in vivo results demonstrated that subspace QALAS had better g-factor maps and could reduce voxel blurring, noise, and artifacts compared to conventional QALAS and showed robust performance at up to nine-fold acceleration with Zero-DeepSub, which enabled whole-brain T1, T2, and PD mapping at 1 mm isotropic resolution within 2 min of scan time. CONCLUSION The proposed subspace QALAS along with Zero-DeepSub enabled high fidelity and rapid whole-brain multiparametric quantification and time-resolved imaging.
Collapse
Affiliation(s)
- Yohan Jun
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, MA, United States
- Department of Radiology, Harvard Medical School, Boston, MA, United States
| | - Yamin Arefeen
- Chandra Family Department of Electrical and Computer Engineering, The University of Texas, Austin, TX, United States
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, United States
| | - Jaejin Cho
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, MA, United States
- Department of Radiology, Harvard Medical School, Boston, MA, United States
| | - Shohei Fujita
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, MA, United States
- Department of Radiology, Harvard Medical School, Boston, MA, United States
| | - Xiaoqing Wang
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, MA, United States
- Department of Radiology, Harvard Medical School, Boston, MA, United States
| | - P. Ellen Grant
- Department of Radiology, Harvard Medical School, Boston, MA, United States
- Fetal-Neonatal Neuroimaging & Developmental Science Center, Boston Children’s Hospital, Boston, MA, United States
| | - Borjan Gagoski
- Department of Radiology, Harvard Medical School, Boston, MA, United States
- Fetal-Neonatal Neuroimaging & Developmental Science Center, Boston Children’s Hospital, Boston, MA, United States
| | - Camilo Jaimes
- Department of Radiology, Harvard Medical School, Boston, MA, United States
- Department of Radiology, Massachusetts General Hospital, Boston, MA, United States
| | - Michael S. Gee
- Department of Radiology, Harvard Medical School, Boston, MA, United States
- Department of Radiology, Massachusetts General Hospital, Boston, MA, United States
| | - Berkin Bilgic
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, MA, United States
- Department of Radiology, Harvard Medical School, Boston, MA, United States
- Harvard/MIT Health Sciences and Technology, Cambridge, MA, United States
| |
Collapse
|
17
|
Heydari A, Ahmadi A, Kim TH, Bilgic B. Joint MAPLE: Accelerated joint T 1 and T 2 * $$ {{\mathrm{T}}_2}^{\ast } $$ mapping with scan-specific self-supervised networks. Magn Reson Med 2024; 91:2294-2309. [PMID: 38181183 PMCID: PMC11007829 DOI: 10.1002/mrm.29989] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Revised: 10/30/2023] [Accepted: 12/11/2023] [Indexed: 01/07/2024]
Abstract
PURPOSE Quantitative MRI finds important applications in clinical and research studies. However, it is encoding intensive and may suffer from prohibitively long scan times. Accelerated MR parameter mapping techniques have been developed to help address these challenges. Here, an accelerated joint T1,T 2 * $$ {{\mathrm{T}}_2}^{\ast } $$ , frequency and proton density mapping technique with scan-specific self-supervised network reconstruction is proposed to synergistically combine parallel imaging, model-based, and deep learning approaches to speed up parameter mapping. METHODS Proposed framework, Joint MAPLE, includes parallel imaging, signal modeling, and data consistency blocks which are optimized jointly in a combined loss function. A scan-specific self-supervised reconstruction is embedded into the framework, which takes advantage of multi-contrast data from a multi-echo, multi-flip angle, gradient echo acquisition. RESULTS In comparison with parallel reconstruction techniques powered by low-rank methods, emerging scan specific networks, and model-basedT 2 * $$ {{\mathrm{T}}_2}^{\ast } $$ estimation approaches, the proposed framework reduces the reconstruction error in parameter maps by approximately two-fold on average at acceleration rates as high as R = 16 with uniform sampling. It can outperform evaluated parallel reconstruction techniques up to four-fold on average in the presence of challenging sub-sampling masks. It is observed that Joint MAPLE performs well at extreme acceleration rates of R = 25 and R = 36 with error values less than 20%. CONCLUSION Joint MAPLE enables higher fidelity parameter estimation at high acceleration rates by synergistically combining parallel imaging and model-based parameter mapping and exploiting multi-echo, multi-flip angle datasets. Utilizing a scan-specific self-supervised reconstruction obviates the need for large data sets for training while improving the parameter estimation ability.
Collapse
Affiliation(s)
- Amir Heydari
- Department of Industrial Engineering and Management Systems, Amirkabir University of Technology, Tehran, Iran
| | - Abbas Ahmadi
- Department of Industrial Engineering and Management Systems, Amirkabir University of Technology, Tehran, Iran
| | - Tae Hyung Kim
- Department of Computer Engineering, Hongik University, Seoul, Korea
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, United States
- Radiology, Harvard Medical School, Boston, MA, United States
| | - Berkin Bilgic
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, United States
- Radiology, Harvard Medical School, Boston, MA, United States
- Harvard/MIT Health Sciences and Technology, Cambridge, MA, United States
| |
Collapse
|
18
|
Qiu Z, Hu S, Zhao W, Sakaie K, Sun JE, Griswold MA, Jones DK, Ma D. Self-calibrated subspace reconstruction for multidimensional MR fingerprinting for simultaneous relaxation and diffusion quantification. Magn Reson Med 2024; 91:1978-1993. [PMID: 38102776 PMCID: PMC10950540 DOI: 10.1002/mrm.29969] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2023] [Revised: 11/22/2023] [Accepted: 11/27/2023] [Indexed: 12/17/2023]
Abstract
PURPOSE To propose a new reconstruction method for multidimensional MR fingerprinting (mdMRF) to address shading artifacts caused by physiological motion-induced measurement errors without navigating or gating. METHODS The proposed method comprises two procedures: self-calibration and subspace reconstruction. The first procedure (self-calibration) applies temporally local matrix completion to reconstruct low-resolution images from a subset of under-sampled data extracted from the k-space center. The second procedure (subspace reconstruction) utilizes temporally global subspace reconstruction with pre-estimated temporal subspace from low-resolution images to reconstruct aliasing-free, high-resolution, and time-resolved images. After reconstruction, a customized outlier detection algorithm was employed to automatically detect and remove images corrupted by measurement errors. Feasibility, robustness, and scan efficiency were evaluated through in vivo human brain imaging experiments. RESULTS The proposed method successfully reconstructed aliasing-free, high-resolution, and time-resolved images, where the measurement errors were accurately represented. The corrupted images were automatically and robustly detected and removed. Artifact-free T1, T2, and ADC maps were generated simultaneously. The proposed reconstruction method demonstrated robustness across different scanners, parameter settings, and subjects. A high scan efficiency of less than 20 s per slice has been achieved. CONCLUSION The proposed reconstruction method can effectively alleviate shading artifacts caused by physiological motion-induced measurement errors. It enables simultaneous and artifact-free quantification of T1, T2, and ADC using mdMRF scans without prospective gating, with robustness and high scan efficiency.
Collapse
Affiliation(s)
- Zhilang Qiu
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, United States
| | - Siyuan Hu
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, United States
| | - Walter Zhao
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, United States
| | - Ken Sakaie
- Imaging Institute, Cleveland Clinic, Cleveland, Ohio, United States
| | - Jessie E.P. Sun
- Department of Radiology, Case Western Reserve University, Cleveland, Ohio, United States
| | - Mark A. Griswold
- Department of Radiology, Case Western Reserve University, Cleveland, Ohio, United States
| | - Derek K. Jones
- Cardiff University Brain Research Imaging Centre (CUBRIC), School of Psychology, Cardiff University, Cardiff, United Kingdom
| | - Dan Ma
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, United States
| |
Collapse
|
19
|
Mao A, Flassbeck S, Assländer J. Bias-Reduced Neural Networks for Parameter Estimation in Quantitative MRI. ARXIV 2024:arXiv:2312.11468v3. [PMID: 38463512 PMCID: PMC10925387] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Subscribe] [Scholar Register] [Indexed: 03/12/2024]
Abstract
Purpose To develop neural network (NN)-based quantitative MRI parameter estimators with minimal bias and a variance close to the Cramér-Rao bound. Theory and Methods We generalize the mean squared error loss to control the bias and variance of the NN's estimates, which involves averaging over multiple noise realizations of the same measurements during training. Bias and variance properties of the resulting NNs are studied for two neuroimaging applications. Results In simulations, the proposed strategy reduces the estimates' bias throughout parameter space and achieves a variance close to the Cramér-Rao bound. In vivo, we observe good concordance between parameter maps estimated with the proposed NNs and traditional estimators, such as non-linear least-squares fitting, while state-of-the-art NNs show larger deviations. Conclusion The proposed NNs have greatly reduced bias compared to those trained using the mean squared error and offer significantly improved computational efficiency over traditional estimators with comparable or better accuracy.
Collapse
Affiliation(s)
- Andrew Mao
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York
- Center for Advanced Imaging Innovation and Research (CAIR), Department of Radiology, New York University Grossman School of Medicine, New York, New York
- Vilcek Institute of Graduate Biomedical Sciences, New York University Grossman School of Medicine, New York, New York
| | - Sebastian Flassbeck
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York
- Center for Advanced Imaging Innovation and Research (CAIR), Department of Radiology, New York University Grossman School of Medicine, New York, New York
| | - Jakob Assländer
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York
- Center for Advanced Imaging Innovation and Research (CAIR), Department of Radiology, New York University Grossman School of Medicine, New York, New York
| |
Collapse
|
20
|
Yarach U, Chatnuntawech I, Setsompop K, Suwannasak A, Angkurawaranon S, Madla C, Hanprasertpong C, Sangpin P. Improved reconstruction for highly accelerated propeller diffusion 1.5 T clinical MRI. MAGMA (NEW YORK, N.Y.) 2024; 37:283-294. [PMID: 38386154 DOI: 10.1007/s10334-023-01142-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/11/2023] [Revised: 12/11/2023] [Accepted: 12/13/2023] [Indexed: 02/23/2024]
Abstract
PURPOSE Propeller fast-spin-echo diffusion magnetic resonance imaging (FSE-dMRI) is essential for the diagnosis of Cholesteatoma. However, at clinical 1.5 T MRI, its signal-to-noise ratio (SNR) remains relatively low. To gain sufficient SNR, signal averaging (number of excitations, NEX) is usually used with the cost of prolonged scan time. In this work, we leveraged the benefits of Locally Low Rank (LLR) constrained reconstruction to enhance the SNR. Furthermore, we enhanced both the speed and SNR by employing Convolutional Neural Networks (CNNs) for the accelerated PROPELLER FSE-dMRI on a 1.5 T clinical scanner. METHODS Residual U-Net (RU-Net) was found to be efficient for propeller FSE-dMRI data. It was trained to predict 2-NEX images obtained by Locally Low Rank (LLR) constrained reconstruction and used 1-NEX images obtained via simplified reconstruction as the inputs. The brain scans from healthy volunteers and patients with cholesteatoma were performed for model training and testing. The performance of trained networks was evaluated with normalized root-mean-square-error (NRMSE), structural similarity index measure (SSIM), and peak SNR (PSNR). RESULTS For 4 × under-sampled with 7 blades data, online reconstruction appears to provide suboptimal images-some small details are missing due to high noise interferences. Offline LLR enables suppression of noises and discovering some small structures. RU-Net demonstrated further improvement compared to LLR by increasing 18.87% of PSNR, 2.11% of SSIM, and reducing 53.84% of NRMSE. Moreover, RU-Net is about 1500 × faster than LLR (0.03 vs. 47.59 s/slice). CONCLUSION The LLR remarkably enhances the SNR compared to online reconstruction. Moreover, RU-Net improves propeller FSE-dMRI as reflected in PSNR, SSIM, and NRMSE. It requires only 1-NEX data, which allows a 2 × scan time reduction. In addition, its speed is approximately 1500 times faster than that of LLR-constrained reconstruction.
Collapse
Affiliation(s)
- Uten Yarach
- Department of Radiologic Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai, Thailand.
| | - Itthi Chatnuntawech
- National Nanotechnology Center, National Science and Technology Development Agency, Pathum Thani, Thailand
| | - Kawin Setsompop
- Department of Radiology, Stanford University, Stanford, CA, USA
| | - Atita Suwannasak
- Department of Radiologic Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai, Thailand
| | - Salita Angkurawaranon
- Department of Radiology, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand
| | - Chakri Madla
- Department of Radiology, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand
| | - Charuk Hanprasertpong
- Department of Otolaryngology, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand
| | | |
Collapse
|
21
|
Feng R, Wu Q, Feng J, She H, Liu C, Zhang Y, Wei H. IMJENSE: Scan-Specific Implicit Representation for Joint Coil Sensitivity and Image Estimation in Parallel MRI. IEEE TRANSACTIONS ON MEDICAL IMAGING 2024; 43:1539-1553. [PMID: 38090839 DOI: 10.1109/tmi.2023.3342156] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/19/2023]
Abstract
Parallel imaging is a commonly used technique to accelerate magnetic resonance imaging (MRI) data acquisition. Mathematically, parallel MRI reconstruction can be formulated as an inverse problem relating the sparsely sampled k-space measurements to the desired MRI image. Despite the success of many existing reconstruction algorithms, it remains a challenge to reliably reconstruct a high-quality image from highly reduced k-space measurements. Recently, implicit neural representation has emerged as a powerful paradigm to exploit the internal information and the physics of partially acquired data to generate the desired object. In this study, we introduced IMJENSE, a scan-specific implicit neural representation-based method for improving parallel MRI reconstruction. Specifically, the underlying MRI image and coil sensitivities were modeled as continuous functions of spatial coordinates, parameterized by neural networks and polynomials, respectively. The weights in the networks and coefficients in the polynomials were simultaneously learned directly from sparsely acquired k-space measurements, without fully sampled ground truth data for training. Benefiting from the powerful continuous representation and joint estimation of the MRI image and coil sensitivities, IMJENSE outperforms conventional image or k-space domain reconstruction algorithms. With extremely limited calibration data, IMJENSE is more stable than supervised calibrationless and calibration-based deep-learning methods. Results show that IMJENSE robustly reconstructs the images acquired at 5× and 6× accelerations with only 4 or 8 calibration lines in 2D Cartesian acquisitions, corresponding to 22.0% and 19.5% undersampling rates. The high-quality results and scanning specificity make the proposed method hold the potential for further accelerating the data acquisition of parallel MRI.
Collapse
|
22
|
Assländer J, Gultekin C, Mao A, Zhang X, Duchemin Q, Liu K, Charlson RW, Shepherd TM, Fernandez-Granda C, Flassbeck S. Rapid quantitative magnetization transfer imaging: Utilizing the hybrid state and the generalized Bloch model. Magn Reson Med 2024; 91:1478-1497. [PMID: 38073093 DOI: 10.1002/mrm.29951] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2023] [Revised: 10/30/2023] [Accepted: 11/14/2023] [Indexed: 02/03/2024]
Abstract
PURPOSE To explore efficient encoding schemes for quantitative magnetization transfer (qMT) imaging with few constraints on model parameters. THEORY AND METHODS We combine two recently proposed models in a Bloch-McConnell equation: the dynamics of the free spin pool are confined to the hybrid state, and the dynamics of the semi-solid spin pool are described by the generalized Bloch model. We numerically optimize the flip angles and durations of a train of radio frequency pulses to enhance the encoding of three qMT parameters while accounting for all eight parameters of the two-pool model. We sparsely sample each time frame along this spin dynamics with a three-dimensional radial koosh-ball trajectory, reconstruct the data with subspace modeling, and fit the qMT model with a neural network for computational efficiency. RESULTS We extracted qMT parameter maps of the whole brain with an effective resolution of 1.24 mm from a 12.6-min scan. In lesions of multiple sclerosis subjects, we observe a decreased size of the semi-solid spin pool and longer relaxation times, consistent with previous reports. CONCLUSION The encoding power of the hybrid state, combined with regularized image reconstruction, and the accuracy of the generalized Bloch model provide an excellent basis for efficient quantitative magnetization transfer imaging with few constraints on model parameters.
Collapse
Affiliation(s)
- Jakob Assländer
- Center for Biomedical Imaging, Department of Radiology, NYU School of Medicine, New York, New York, USA
- Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, NYU School of Medicine, New York, New York, USA
| | - Cem Gultekin
- Courant Institute of Mathematical Sciences, New York University, New York, New York, USA
| | - Andrew Mao
- Center for Biomedical Imaging, Department of Radiology, NYU School of Medicine, New York, New York, USA
- Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, NYU School of Medicine, New York, New York, USA
- Vilcek Institute of Graduate Biomedical Sciences, NYU School of Medicine, New York, New York, USA
| | - Xiaoxia Zhang
- Center for Biomedical Imaging, Department of Radiology, NYU School of Medicine, New York, New York, USA
- Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, NYU School of Medicine, New York, New York, USA
| | - Quentin Duchemin
- Laboratoire d'analyse et de mathématiques appliquées, Université Gustave Eiffel, Champs-sur-Marne, France
| | - Kangning Liu
- Center for Data Science, New York University, New York, New York, USA
| | - Robert W Charlson
- Department of Neurology, NYU School of Medicine, New York, New York, USA
| | - Timothy M Shepherd
- Center for Biomedical Imaging, Department of Radiology, NYU School of Medicine, New York, New York, USA
| | - Carlos Fernandez-Granda
- Courant Institute of Mathematical Sciences, New York University, New York, New York, USA
- Center for Data Science, New York University, New York, New York, USA
| | - Sebastian Flassbeck
- Center for Biomedical Imaging, Department of Radiology, NYU School of Medicine, New York, New York, USA
- Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, NYU School of Medicine, New York, New York, USA
| |
Collapse
|
23
|
Assländer J, Mao A, Marchetto E, Beck ES, La Rosa F, Charlson RW, Shepherd TM, Flassbeck S. Unconstrained quantitative magnetization transfer imaging: disentangling T1 of the free and semi-solid spin pools. ARXIV 2024:arXiv:2301.08394v3. [PMID: 36713253 PMCID: PMC9882584] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Figures] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Since the inception of magnetization transfer (MT) imaging, it has been widely assumed that Henkelman's two spin pools have similar longitudinal relaxation times, which motivated many researchers to constrain them to each other. However, several recent publications reported a T 1 s of the semi-solid spin pool that is much shorter than T 1 f of the free pool. While these studies tailored experiments for robust proofs-of-concept, we here aim to quantify the disentangled relaxation processes on a voxel-by-voxel basis in a clinical imaging setting, i.e., with an effective resolution of 1.24mm isotropic and full brain coverage in 12min. To this end, we optimized a hybrid-state pulse sequence for mapping the parameters of an unconstrained MT model. We scanned four people with relapsing-remitting multiple sclerosis (MS) and four healthy controls with this pulse sequence and estimated T 1 f ≈ 1.84 s and T 1 s ≈ 0.34 s in healthy white matter. Our results confirm the reports that T 1 s ≪ T 1 f and we argue that this finding identifies MT as an inherent driver of longitudinal relaxation in brain tissue. Moreover, we estimated a fractional size of the semi-solid spin pool of m 0 s ≈ 0.212 , which is larger than previously assumed. An analysis of T 1 f in normal-appearing white matter revealed statistically significant differences between individuals with MS and controls.
Collapse
Affiliation(s)
- Jakob Assländer
- Center for Biomedical Imaging, Dept. of Radiology, New York University School of Medicine, 650 1st Avenue, New York, 10016, NY, USA
- Center for Advanced Imaging Innovation and Research (CAI R), Dept. of Radiology, New York University School of Medicine, 650 1st Avenue, New York, 10016, NY, USA
| | - Andrew Mao
- Center for Biomedical Imaging, Dept. of Radiology, New York University School of Medicine, 650 1st Avenue, New York, 10016, NY, USA
- Center for Advanced Imaging Innovation and Research (CAI R), Dept. of Radiology, New York University School of Medicine, 650 1st Avenue, New York, 10016, NY, USA
- Vilcek Institute of Graduate Biomedical Sciences, New York University School of Medicine, 550 1st Avenue, New York, 10016, NY, USA
| | - Elisa Marchetto
- Center for Biomedical Imaging, Dept. of Radiology, New York University School of Medicine, 650 1st Avenue, New York, 10016, NY, USA
- Center for Advanced Imaging Innovation and Research (CAI R), Dept. of Radiology, New York University School of Medicine, 650 1st Avenue, New York, 10016, NY, USA
| | - Erin S Beck
- Corinne Goldsmith Dickinson Center for Multiple Sclerosis, Department of Neurology, Icahn School of Medicine at Mount Sinai, 5 East 98th Street, New York, 10029, NY, USA
| | - Francesco La Rosa
- Corinne Goldsmith Dickinson Center for Multiple Sclerosis, Department of Neurology, Icahn School of Medicine at Mount Sinai, 5 East 98th Street, New York, 10029, NY, USA
| | - Robert W Charlson
- Department of Neurology, New York University School of Medicine, 240 E 38th Street, New York, 10016, NY, USA
| | - Timothy M Shepherd
- Center for Biomedical Imaging, Dept. of Radiology, New York University School of Medicine, 650 1st Avenue, New York, 10016, NY, USA
| | - Sebastian Flassbeck
- Center for Biomedical Imaging, Dept. of Radiology, New York University School of Medicine, 650 1st Avenue, New York, 10016, NY, USA
- Center for Advanced Imaging Innovation and Research (CAI R), Dept. of Radiology, New York University School of Medicine, 650 1st Avenue, New York, 10016, NY, USA
| |
Collapse
|
24
|
Cao X, Liao C, Zhou Z, Zhong Z, Li Z, Dai E, Iyer SS, Hannum AJ, Yurt M, Schauman S, Chen Q, Wang N, Wei J, Yan Y, He H, Skare S, Zhong J, Kerr A, Setsompop K. DTI-MR fingerprinting for rapid high-resolution whole-brain T 1 , T 2 , proton density, ADC, and fractional anisotropy mapping. Magn Reson Med 2024; 91:987-1001. [PMID: 37936313 PMCID: PMC11068310 DOI: 10.1002/mrm.29916] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2023] [Revised: 10/17/2023] [Accepted: 10/18/2023] [Indexed: 11/09/2023]
Abstract
PURPOSE This study aims to develop a high-efficiency and high-resolution 3D imaging approach for simultaneous mapping of multiple key tissue parameters for routine brain imaging, including T1 , T2 , proton density (PD), ADC, and fractional anisotropy (FA). The proposed method is intended for pushing routine clinical brain imaging from weighted imaging to quantitative imaging and can also be particularly useful for diffusion-relaxometry studies, which typically suffer from lengthy acquisition time. METHODS To address challenges associated with diffusion weighting, such as shot-to-shot phase variation and low SNR, we integrated several innovative data acquisition and reconstruction techniques. Specifically, we used M1-compensated diffusion gradients, cardiac gating, and navigators to mitigate phase variations caused by cardiac motion. We also introduced a data-driven pre-pulse gradient to cancel out eddy currents induced by diffusion gradients. Additionally, to enhance image quality within a limited acquisition time, we proposed a data-sharing joint reconstruction approach coupled with a corresponding sequence design. RESULTS The phantom and in vivo studies indicated that the T1 and T2 values measured by the proposed method are consistent with a conventional MR fingerprinting sequence and the diffusion results (including diffusivity, ADC, and FA) are consistent with the spin-echo EPI DWI sequence. CONCLUSION The proposed method can achieve whole-brain T1 , T2 , diffusivity, ADC, and FA maps at 1-mm isotropic resolution within 10 min, providing a powerful tool for investigating the microstructural properties of brain tissue, with potential applications in clinical and research settings.
Collapse
Affiliation(s)
- Xiaozhi Cao
- Department of Radiology, Stanford University, Stanford, CA, USA
- Department of Electrical Engineering, Stanford University, Stanford, CA, USA
| | - Congyu Liao
- Department of Radiology, Stanford University, Stanford, CA, USA
- Department of Electrical Engineering, Stanford University, Stanford, CA, USA
| | - Zihan Zhou
- Department of Radiology, Stanford University, Stanford, CA, USA
| | - Zheng Zhong
- Department of Radiology, Stanford University, Stanford, CA, USA
| | - Zhitao Li
- Department of Radiology, Stanford University, Stanford, CA, USA
| | - Erpeng Dai
- Department of Radiology, Stanford University, Stanford, CA, USA
| | - Siddharth Srinivasan Iyer
- Department of Radiology, Stanford University, Stanford, CA, USA
- Department of Electrical Engineering and Computer Science, MIT, Cambridge, Massachusetts, USA
| | - Ariel J Hannum
- Department of Radiology, Stanford University, Stanford, CA, USA
- Department of Bioengineering, Stanford University, Stanford, CA, USA
| | - Mahmut Yurt
- Department of Radiology, Stanford University, Stanford, CA, USA
- Department of Electrical Engineering, Stanford University, Stanford, CA, USA
| | - Sophie Schauman
- Department of Radiology, Stanford University, Stanford, CA, USA
- Department of Electrical Engineering, Stanford University, Stanford, CA, USA
| | - Quan Chen
- Department of Radiology, Stanford University, Stanford, CA, USA
- Department of Electrical Engineering, Stanford University, Stanford, CA, USA
| | - Nan Wang
- Department of Radiology, Stanford University, Stanford, CA, USA
- Department of Electrical Engineering, Stanford University, Stanford, CA, USA
| | - Jintao Wei
- Center for Brain Imaging Science and Technology, Zhejiang University, Hangzhou, Zhejiang, China
| | - Yifan Yan
- School of Public Health and the Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China
| | - Hongjian He
- Center for Brain Imaging Science and Technology, Zhejiang University, Hangzhou, Zhejiang, China
- School of Physics, Zhejiang University, Hangzhou, Zhejiang, China
| | - Stefan Skare
- Department of Clinical Neuroscience, Karolinska Institute, Stockholm, Sweden
| | - Jianhui Zhong
- Department of Imaging Sciences, University of Rochester, NY, USA
| | - Adam Kerr
- Department of Electrical Engineering, Stanford University, Stanford, CA, USA
| | - Kawin Setsompop
- Department of Radiology, Stanford University, Stanford, CA, USA
- Department of Electrical Engineering, Stanford University, Stanford, CA, USA
| |
Collapse
|
25
|
Xiang J, Lamy J, Qiu M, Galiana G, Peters DC. K-t PCA accelerated in-plane balanced steady-state free precession phase-contrast (PC-SSFP) for all-in-one diastolic function evaluation. Magn Reson Med 2024; 91:911-925. [PMID: 37927206 PMCID: PMC10803002 DOI: 10.1002/mrm.29897] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Revised: 10/04/2023] [Accepted: 10/05/2023] [Indexed: 11/07/2023]
Abstract
PURPOSE Diastolic function evaluation requires estimates of early and late diastolic mitral filling velocities (E and A) and of mitral annulus tissue velocity (e'). We aimed to develop an MRI method for simultaneous all-in-one diastolic function evaluation in a single scan by generating a 2D phase-contrast (PC) sequence with balanced steady-state free precession (bSSFP) contrast (PC-SSFP). E and A could then be measured with PC, and e' estimated by valve tracking on the magnitude images, using an established deep learning framework. METHODS Our PC-SSFP used in-plane flow-encoding, with zeroth and first moment nulling over each TR. For further acceleration, different k-t principal component analysis (PCA) methods were investigated with both retrospective and prospective undersampling. PC-SSFP was compared to separate balanced SSFP cine and PC-gradient echo acquisitions in phantoms and in 10 healthy subjects. RESULTS Phantom experiments showed that PC-SSFP measured accurate velocities compared to PC-gradient echo (r = 0.98 for a range of pixel-wise velocities -80 cm/s to 80 cm/s). In subjects, PC-SSFP generated high SNR and myocardium-blood contrast, and excellent agreement for E (limits of agreement [LOA] 0.8 ± 2.4 cm/s, r = 0.98), A (LOA 2.5 ± 4.1 cm/s, r = 0.97), and e' (LOA 0.3 ± 2.6 cm/s, r = 1.00), versus the standard methods. The best k-t PCA approach processed the complex difference data and substituted in raw k-space data. With prospective k-t PCA acceleration, higher frame rates were achieved (50 vs. 25 frames per second without k-t PCA), yielding a 13% higher e'. CONCLUSION The proposed PC-SSFP method achieved all-in-one diastolic function evaluation.
Collapse
Affiliation(s)
- Jie Xiang
- Department of Biomedical Engineering, Yale University, New Haven, CT, United States
| | - Jerome Lamy
- Université de Paris, Cardiovascular Research Center, INSERM, 75015 Paris, France
| | - Maolin Qiu
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, United States
| | - Gigi Galiana
- Department of Biomedical Engineering, Yale University, New Haven, CT, United States
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, United States
| | - Dana C. Peters
- Department of Biomedical Engineering, Yale University, New Haven, CT, United States
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, United States
| |
Collapse
|
26
|
Douest Y, Forrest RM, Ter-Ovanessian B, Courtois N, Tancret F, Greer AL, Chevalier J, Fabrègue D. Machine learning-guided exploration and experimental assessment of unreported compositions in the quaternary Ti-Zr-Cu-Pd biocompatible metallic glass system. Acta Biomater 2024; 175:411-421. [PMID: 38135205 DOI: 10.1016/j.actbio.2023.12.028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Revised: 11/21/2023] [Accepted: 12/17/2023] [Indexed: 12/24/2023]
Abstract
Due to their outstanding elastic limit, biocompatible Ti-based bulk metallic glasses (BMGs) are candidate materials to decrease the size of medical implants and therefore reduce their invasiveness. However, the practical use of classical Ti-BMGs in medical applications is in part hindered by their high copper content: more effort is thus required to design low-copper Ti-BMGs. In this work, in line with current rise in AI-driven tools, machine learning (ML) approaches, a neural-network ML model is used to explore the glass-forming ability (GFA) of unreported low-copper compositions within the biocompatible Ti-Zr-Cu-Pd system. Two types of models are trained and compared: one based on the alloy composition only, and a second based on various features derived from the alloying elements. Contrary to expectation, the predictive power of both models in evaluating GFA is similar. The compositional space identified by ML as promising is experimentally assessed, finding unfortunately low GFA. These results indicate that the ML approach may be premature for specific composition tuning of amorphous metallic materials. We emphasise that the development of ML tools in GFA prediction requires an improvement of the dataset, in terms of homogeneity, size and GFA descriptors, which must be supported by increased reporting of high-quality experimental GFA measurements, both positive and negative. STATEMENT OF SIGNIFICANCE: Biocompatible Ti-based bulk metallic glasses (BMGs) are candidate materials for use in the next generation of minimally invasive dental implants where improved mechanical properties, such as high strength are required. Despite promising in vitro/vivo evaluations, implementation of alloys for practical applications is partly hindered by the presence of copper as the main alloying element. Recent studies have presented AI-guided and machine learning strategies as appealing approaches to understand and describe the glass forming ability (GFA) of BMG-forming compositions. In this work, we employ and evaluate the capacity of a machine-learning model to explore low-copper compositional spaces in the biocompatible Ti-Zr-Cu-Pd system. Our results highlight the limits of such a computational approach and suggest improvements for future designing routes.
Collapse
Affiliation(s)
- Yohan Douest
- Anthogyr SAS, 2237 Avenue André Lasquin, 74700 Sallanches, France; INSA-Lyon, Université de Lyon, UMR CNRS 5510 MATEIS, 20 Avenue Albert Einstein, 69621 Villeurbanne CEDEX, France.
| | - Robert M Forrest
- Department of Materials Science and Metallurgy, University of Cambridge, 27 Charles Babbage Road, Cambridge CB3 0FS, UK
| | - Benoit Ter-Ovanessian
- INSA-Lyon, Université de Lyon, UMR CNRS 5510 MATEIS, 20 Avenue Albert Einstein, 69621 Villeurbanne CEDEX, France
| | - Nicolas Courtois
- Anthogyr SAS, 2237 Avenue André Lasquin, 74700 Sallanches, France
| | - Franck Tancret
- Université de Nantes, Institut des Matériaux Jean Rouxel (IMN), UMR CNRS 6502, Polytech Nantes, Rue Christian Pauc, BP 50609, 44306 Nantes CEDEX 3, France
| | - A Lindsay Greer
- Department of Materials Science and Metallurgy, University of Cambridge, 27 Charles Babbage Road, Cambridge CB3 0FS, UK
| | - Jérôme Chevalier
- INSA-Lyon, Université de Lyon, UMR CNRS 5510 MATEIS, 20 Avenue Albert Einstein, 69621 Villeurbanne CEDEX, France
| | - Damien Fabrègue
- INSA-Lyon, Université de Lyon, UMR CNRS 5510 MATEIS, 20 Avenue Albert Einstein, 69621 Villeurbanne CEDEX, France
| |
Collapse
|
27
|
Xu J, Zu T, Hsu YC, Wang X, Chan KWY, Zhang Y. Accelerating CEST imaging using a model-based deep neural network with synthetic training data. Magn Reson Med 2024; 91:583-599. [PMID: 37867413 DOI: 10.1002/mrm.29889] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2023] [Revised: 08/31/2023] [Accepted: 09/25/2023] [Indexed: 10/24/2023]
Abstract
PURPOSE To develop a model-based deep neural network for high-quality image reconstruction of undersampled multi-coil CEST data. THEORY AND METHODS Inspired by the variational network (VN), the CEST image reconstruction equation is unrolled into a deep neural network (CEST-VN) with a k-space data-sharing block that takes advantage of the inherent redundancy in adjacent CEST frames and 3D spatial-frequential convolution kernels that exploit correlations in the x-ω domain. Additionally, a new pipeline based on multiple-pool Bloch-McConnell simulations is devised to synthesize multi-coil CEST data from publicly available anatomical MRI data. The proposed network is trained on simulated data with a CEST-specific loss function that jointly measures the structural and CEST contrast. The performance of CEST-VN was evaluated on four healthy volunteers and five brain tumor patients using retrospectively or prospectively undersampled data with various acceleration factors, and then compared with other conventional and state-of-the-art reconstruction methods. RESULTS The proposed CEST-VN method generated high-quality CEST source images and amide proton transfer-weighted maps in healthy and brain tumor subjects, consistently outperforming GRAPPA, blind compressed sensing, and the original VN. With the acceleration factors increasing from 3 to 6, CEST-VN with the same hyperparameters yielded similar and accurate reconstruction without apparent loss of details or increase of artifacts. The ablation studies confirmed the effectiveness of the CEST-specific loss function and data-sharing block used. CONCLUSIONS The proposed CEST-VN method can offer high-quality CEST source images and amide proton transfer-weighted maps from highly undersampled multi-coil data by integrating the deep learning prior and multi-coil sensitivity encoding model.
Collapse
Affiliation(s)
- Jianping Xu
- Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, People's Republic of China
| | - Tao Zu
- Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, People's Republic of China
| | - Yi-Cheng Hsu
- MR Collaboration, Siemens Healthcare Ltd., Shanghai, People's Republic of China
| | - Xiaoli Wang
- School of Medical Imaging, Weifang Medical University, Weifang, People's Republic of China
| | - Kannie W Y Chan
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, People's Republic of China
| | - Yi Zhang
- Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, People's Republic of China
| |
Collapse
|
28
|
Jin R, Li Y, Shosted RK, Xing F, Gilbert I, Perry JL, Woo J, Liang ZP, Sutton BP. Optimization of 3D dynamic speech MRI: Poisson-disc undersampling and locally higher-rank reconstruction through partial separability model with regional optimized temporal basis. Magn Reson Med 2024; 91:61-74. [PMID: 37677043 PMCID: PMC10847962 DOI: 10.1002/mrm.29812] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2023] [Revised: 07/09/2023] [Accepted: 07/12/2023] [Indexed: 09/09/2023]
Abstract
PURPOSE To improve the spatiotemporal qualities of images and dynamics of speech MRI through an improved data sampling and image reconstruction approach. METHODS For data acquisition, we used a Poisson-disc random under sampling scheme that reduced the undersampling coherence. For image reconstruction, we proposed a novel locally higher-rank partial separability model. This reconstruction model represented the oral and static regions using separate low-rank subspaces, therefore, preserving their distinct temporal signal characteristics. Regional optimized temporal basis was determined from the regional-optimized virtual coil approach. Overall, we achieved a better spatiotemporal image reconstruction quality with the potential of reducing total acquisition time by 50%. RESULTS The proposed method was demonstrated through several 2-mm isotropic, 64 mm total thickness, dynamic acquisitions with 40 frames per second and compared to the previous approach using a global subspace model along with other k-space sampling patterns. Individual timeframe images and temporal profiles of speech samples were shown to illustrate the ability of the Poisson-disc under sampling pattern in reducing total acquisition time. Temporal information of sagittal and coronal directions was also shown to illustrate the effectiveness of the locally higher-rank operator and regional optimized temporal basis. To compare the reconstruction qualities of different regions, voxel-wise temporal SNR analysis were performed. CONCLUSION Poisson-disc sampling combined with a locally higher-rank model and a regional-optimized temporal basis can drastically improve the spatiotemporal image quality and provide a 50% reduction in overall acquisition time.
Collapse
Affiliation(s)
- Riwei Jin
- Department of Bioengineering, University of Illinois Urbana-Champaign, Urbana, Illinois, USA
- Beckman Institute for Advanced Science and Technology, University of Illinois Urbana-Champaign, Urbana, Illinois, USA
| | - Yudu Li
- Beckman Institute for Advanced Science and Technology, University of Illinois Urbana-Champaign, Urbana, Illinois, USA
- National Center for Supercomputing Applications, University of Illinois Urbana-Champaign, Urbana, Illinois, USA
| | - Ryan K Shosted
- Department of Linguistics, University of Illinois Urbana-Champaign, Urbana, Illinois, USA
| | - Fangxu Xing
- Gordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital/Harvard Medical School, Boston, Massachusetts, USA
| | - Imani Gilbert
- Department of Communication Sciences and Disorders, East Carolina University, Greenville, North Carolina, USA
| | - Jamie L Perry
- Department of Communication Sciences and Disorders, East Carolina University, Greenville, North Carolina, USA
| | - Jonghye Woo
- Gordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital/Harvard Medical School, Boston, Massachusetts, USA
| | - Zhi-Pei Liang
- Beckman Institute for Advanced Science and Technology, University of Illinois Urbana-Champaign, Urbana, Illinois, USA
- National Center for Supercomputing Applications, University of Illinois Urbana-Champaign, Urbana, Illinois, USA
- Department of Electrical and Computer Engineering, University of Illinois Urbana-Champaign, Urbana, Illinois, USA
| | - Bradley P Sutton
- Department of Bioengineering, University of Illinois Urbana-Champaign, Urbana, Illinois, USA
- Beckman Institute for Advanced Science and Technology, University of Illinois Urbana-Champaign, Urbana, Illinois, USA
- National Center for Supercomputing Applications, University of Illinois Urbana-Champaign, Urbana, Illinois, USA
- Carle Illinois College of Medicine, University of Illinois Urbana-Champaign, Urbana, Illinois, USA
| |
Collapse
|
29
|
Guan Y, Li Y, Liu R, Meng Z, Li Y, Ying L, Du YP, Liang ZP. Subspace Model-Assisted Deep Learning for Improved Image Reconstruction. IEEE TRANSACTIONS ON MEDICAL IMAGING 2023; 42:3833-3846. [PMID: 37682643 DOI: 10.1109/tmi.2023.3313421] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/10/2023]
Abstract
Image reconstruction from limited and/or sparse data is known to be an ill-posed problem and a priori information/constraints have played an important role in solving the problem. Early constrained image reconstruction methods utilize image priors based on general image properties such as sparsity, low-rank structures, spatial support bound, etc. Recent deep learning-based reconstruction methods promise to produce even higher quality reconstructions by utilizing more specific image priors learned from training data. However, learning high-dimensional image priors requires huge amounts of training data that are currently not available in medical imaging applications. As a result, deep learning-based reconstructions often suffer from two known practical issues: a) sensitivity to data perturbations (e.g., changes in data sampling scheme), and b) limited generalization capability (e.g., biased reconstruction of lesions). This paper proposes a new method to address these issues. The proposed method synergistically integrates model-based and data-driven learning in three key components. The first component uses the linear vector space framework to capture global dependence of image features; the second exploits a deep network to learn the mapping from a linear vector space to a nonlinear manifold; the third is an unrolling-based deep network that captures local residual features with the aid of a sparsity model. The proposed method has been evaluated with magnetic resonance imaging data, demonstrating improved reconstruction in the presence of data perturbation and/or novel image features. The method may enhance the practical utility of deep learning-based image reconstruction.
Collapse
|
30
|
Liu X, He J, Mi C, Zhang X. Low-rank plus sparse joint smoothing model based on tensor singular value decomposition for dynamic MRI reconstruction. Magn Reson Imaging 2023; 104:52-60. [PMID: 37741515 DOI: 10.1016/j.mri.2023.09.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2022] [Revised: 08/15/2023] [Accepted: 09/17/2023] [Indexed: 09/25/2023]
Abstract
Dynamic magnetic resonance imaging (DMRI) is an important medical imaging modality, but the long imaging time limits its practical applications. This paper proposes a low-rank plus sparse joint smoothing model based on tensor singular value decomposition (T-SVD) to reconstruct DMR images from highly under-sampled k-t space data. The low-rank plus sparse tensor (ℒ+S) model decomposes the DMR data into a low-rank and sparse tensor, which naturally fits the dynamic MR images characteristics and exploits the spatiotemporal correlation of DMRI data to improve reconstruction effect. T-SVD is utilized in the ℒ+S model to maintain the intrinsic structure of the low-rank tensor and further enhance the low-rank property. In addition, considering the global multi-dimensional smoothness of the DMR images, the proposed method joint tensor total variation (TTV) constraints to utilize the smoothness of DMR images to obtain more reconstruction details while protecting the global structure. We conducted experiments on the dynamic cardiac datasets, and the experiment results show that the proposed method has superior performance to several state-of-the-art imaging methods.
Collapse
Affiliation(s)
- Xiaotong Liu
- Tianjin Key Laboratory of Electronic Materials and Devices, School of Electronics and Information Engineering, Hebei University of Technology, 340 Xiping Road, Beichen District, Tianjin 300401, PR China
| | - Jingfei He
- Tianjin Key Laboratory of Electronic Materials and Devices, School of Electronics and Information Engineering, Hebei University of Technology, 340 Xiping Road, Beichen District, Tianjin 300401, PR China.
| | - Chenghu Mi
- Tianjin Key Laboratory of Electronic Materials and Devices, School of Electronics and Information Engineering, Hebei University of Technology, 340 Xiping Road, Beichen District, Tianjin 300401, PR China
| | - Xiaoyue Zhang
- Tianjin Key Laboratory of Electronic Materials and Devices, School of Electronics and Information Engineering, Hebei University of Technology, 340 Xiping Road, Beichen District, Tianjin 300401, PR China
| |
Collapse
|
31
|
Mao A, Flassbeck S, Gultekin C, Assländer J. Cramér-Rao Bound Optimized Subspace Reconstruction in Quantitative MRI. ARXIV 2023:arXiv:2305.00326v2. [PMID: 37961734 PMCID: PMC10635289] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Subscribe] [Scholar Register] [Indexed: 11/15/2023]
Abstract
We extend the traditional framework for estimating subspace bases that maximize the preserved signal energy to additionally preserve the Cramér-Rao bound (CRB) of the biophysical parameters and, ultimately, improve accuracy and precision in the quantitative maps. To this end, we introduce an approximate compressed CRB based on orthogonalized versions of the signal's derivatives with respect to the model parameters. This approximation permits singular value decomposition (SVD)-based minimization of both the CRB and signal losses during compression. Compared to the traditional SVD approach, the proposed method better preserves the CRB across all biophysical parameters with negligible cost to the preserved signal energy, leading to reduced bias and variance of the parameter estimates in simulation. In vivo, improved accuracy and precision are observed in two quantitative neuroimaging applications, permitting the use of smaller basis sizes in subspace reconstruction and offering significant computational savings.
Collapse
Affiliation(s)
- Andrew Mao
- Center for Biomedical Imaging, NYU School of Medicine, New York, NY 10016
| | | | - Cem Gultekin
- Courant Institute of Mathematical Sciences, New York University, New York, NY 10012
| | - Jakob Assländer
- Center for Biomedical Imaging, NYU School of Medicine, New York, NY 10016
| |
Collapse
|
32
|
Meyer NK, Kang D, Ahmed Z, In MH, Shu Y, Huston J, Bernstein MA, Trzasko JD. Locally Low-Rank Denoising of Multi-Echo Functional MRI Data With Application in Resting-State Analysis. Top Magn Reson Imaging 2023; 32:37-49. [PMID: 37796647 PMCID: PMC10549890 DOI: 10.1097/rmr.0000000000000307] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2023] [Revised: 07/28/2023] [Accepted: 08/06/2023] [Indexed: 09/29/2023]
Abstract
OBJECTIVES Locally low-rank (LLR) denoising of functional magnetic resonance imaging (fMRI) time series image data is extended to multi-echo (ME) data. The proposed method extends the capabilities of non-physiologic noise suppression beyond single-echo applications with a dedicated ME algorithm. MATERIALS AND METHODS Following an institutional review board (IRB) approved protocol, resting-state fMRI data were acquired in 7 healthy subjects. A compact 3T scanner enabled whole-brain acquisition of multiband ME fMRI data at high spatial resolution (1.4 × 1.4 × 2.8 mm 3 ) with a 1810 ms repetition time (TR). Image data were denoised with ME-LLR preceding functional processing. The results of connectivity maps generated from denoised data were compared with maps generated with equivalent processing of non-denoised images. To assess ME-LLR as a method to reduce scan time, comparisons were made between maps computed from image data with full and retrospectively truncated durations. Assessments were completed with seed-based connectivity analyses using echo-combined image data. In a feasibility assessment, nondenoised and denoised full-duration echo-combined data were equivalently processed with independent component analysis (ICA) and compared. RESULTS ME-LLR denoising yielded strengthened resting-state network connectivity maps after nuisance regression and seed-based connectivity analysis. In assessing ME-LLR as a scan reduction mechanism, maps generated from denoised data at half scan time showed comparable quality with maps generated from full-duration, non-denoised data, at both single subject and group levels. ME-LLR substantially increased temporal signal-to-noise ratio (tSNR) for image data respective to each individual echo and for image data after nuisance regression. Among echo-specific image volumes, increases in tSNR yielded by ME-LLR were most pronounced for image data with the longest echo time and thereby lowest SNR. ICA showed resting-state networks consistently identified between non-denoised and denoised data, with clearer demarcation of networks for ME-LLR. CONCLUSIONS ME-LLR is demonstrated to suppress non-physiologic noise, enhance functional connectivity map quality, and could potentially facilitate scan time reduction in ME-fMRI.
Collapse
Affiliation(s)
| | - Daehun Kang
- Department of Radiology, Mayo Clinic, Rochester, MN
| | - Zaki Ahmed
- Department of Radiology, Mayo Clinic, Rochester, MN
- Radiology, Corewell Health William Beaumont University Hospital, Royal Oak, MI
| | - Myung-Ho In
- Department of Radiology, Mayo Clinic, Rochester, MN
| | - Yunhong Shu
- Department of Radiology, Mayo Clinic, Rochester, MN
| | - John Huston
- Department of Radiology, Mayo Clinic, Rochester, MN
| | | | | |
Collapse
|
33
|
Arefeen Y, Xu J, Zhang M, Dong Z, Wang F, White J, Bilgic B, Adalsteinsson E. Latent signal models: Learning compact representations of signal evolution for improved time-resolved, multi-contrast MRI. Magn Reson Med 2023; 90:483-501. [PMID: 37093775 DOI: 10.1002/mrm.29657] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Revised: 03/09/2023] [Accepted: 03/16/2023] [Indexed: 04/25/2023]
Abstract
PURPOSE To improve time-resolved reconstructions by training auto-encoders to learn compact representations of Bloch-simulated signal evolution and inserting the decoder into the forward model. METHODS Building on model-based nonlinear and linear subspace techniques, we train auto-encoders on dictionaries of simulated signal evolution to learn compact, nonlinear, latent representations. The proposed latent signal model framework inserts the decoder portion of the auto-encoder into the forward model and directly reconstructs the latent representation. Latent signal models essentially serve as a proxy for fast and feasible differentiation through the Bloch equations used to simulate signal. This work performs experiments in the context of T2 -shuffling, gradient echo EPTI, and MPRAGE-shuffling. We compare how efficiently auto-encoders represent signal evolution in comparison to linear subspaces. Simulation and in vivo experiments then evaluate if reducing degrees of freedom by incorporating our proxy for the Bloch equations, the decoder portion of the auto-encoder, into the forward model improves reconstructions in comparison to subspace constraints. RESULTS An auto-encoder with 1 real latent variable represents single-tissue fast spin echo, EPTI, and MPRAGE signal evolution to within 0.15% normalized RMS error, enabling reconstruction problems with 3 degrees of freedom per voxel (real latent variable + complex scaling) in comparison to linear models with 4-8 degrees of freedom per voxel. In simulated/in vivo T2 -shuffling and in vivo EPTI experiments, the proposed framework achieves consistent quantitative normalized RMS error improvement over linear approaches. From qualitative evaluation, the proposed approach yields images with reduced blurring and noise amplification in MPRAGE-shuffling experiments. CONCLUSION Directly solving for nonlinear latent representations of signal evolution improves time-resolved MRI reconstructions.
Collapse
Affiliation(s)
- Yamin Arefeen
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| | - Junshen Xu
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| | - Molin Zhang
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| | - Zijing Dong
- Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, Massachusetts, USA
| | - Fuyixue Wang
- Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, Massachusetts, USA
| | - Jacob White
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| | - Berkin Bilgic
- Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, Massachusetts, USA
- Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
| | - Elfar Adalsteinsson
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
- Harvard-MIT Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
- Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| |
Collapse
|
34
|
Paajanen A, Hanhela M, Hänninen N, Nykänen O, Kolehmainen V, Nissi MJ. Fast Compressed Sensing of 3D Radial T 1 Mapping with Different Sparse and Low-Rank Models. J Imaging 2023; 9:151. [PMID: 37623683 PMCID: PMC10455972 DOI: 10.3390/jimaging9080151] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2023] [Revised: 07/14/2023] [Accepted: 07/21/2023] [Indexed: 08/26/2023] Open
Abstract
Knowledge of the relative performance of the well-known sparse and low-rank compressed sensing models with 3D radial quantitative magnetic resonance imaging acquisitions is limited. We use 3D radial T1 relaxation time mapping data to compare the total variation, low-rank, and Huber penalty function approaches to regularization to provide insights into the relative performance of these image reconstruction models. Simulation and ex vivo specimen data were used to determine the best compressed sensing model as measured by normalized root mean squared error and structural similarity index. The large-scale compressed sensing models were solved by combining a GPU implementation of a preconditioned primal-dual proximal splitting algorithm to provide high-quality T1 maps within a feasible computation time. The model combining spatial total variation and locally low-rank regularization yielded the best performance, followed closely by the model combining spatial and contrast dimension total variation. Computation times ranged from 2 to 113 min, with the low-rank approaches taking the most time. The differences between the compressed sensing models are not necessarily large, but the overall performance is heavily dependent on the imaged object.
Collapse
Affiliation(s)
| | | | | | | | | | - Mikko J. Nissi
- Department of Technical Physics, University of Eastern Finland, 70211 Kuopio, Finland; (A.P.); (M.H.); (N.H.); (O.N.); (V.K.)
| |
Collapse
|
35
|
Bian W, Jang A, Liu F. Magnetic Resonance Parameter Mapping using Self-supervised Deep Learning with Model Reinforcement. ARXIV 2023:arXiv:2307.13211v1. [PMID: 37547657 PMCID: PMC10402181] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Subscribe] [Scholar Register] [Indexed: 08/08/2023]
Abstract
This paper proposes a novel self-supervised learning method, RELAX-MORE, for quantitative MRI (qMRI) reconstruction. The proposed method uses an optimization algorithm to unroll a model-based qMRI reconstruction into a deep learning framework, enabling the generation of highly accurate and robust MR parameter maps at imaging acceleration. Unlike conventional deep learning methods requiring a large amount of training data, RELAX-MORE is a subject-specific method that can be trained on single-subject data through self-supervised learning, making it accessible and practically applicable to many qMRI studies. Using the quantitative T 1 mapping as an example at different brain, knee and phantom experiments, the proposed method demonstrates excellent performance in reconstructing MR parameters, correcting imaging artifacts, removing noises, and recovering image features at imperfect imaging conditions. Compared with other state-of-the-art conventional and deep learning methods, RELAX-MORE significantly improves efficiency, accuracy, robustness, and generalizability for rapid MR parameter mapping. This work demonstrates the feasibility of a new self-supervised learning method for rapid MR parameter mapping, with great potential to enhance the clinical translation of qMRI.
Collapse
Affiliation(s)
- Wanyu Bian
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA 02129 USA
| | - Albert Jang
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA 02129 USA
| | - Fang Liu
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA 02129 USA
| |
Collapse
|
36
|
Demirel ÖB, Weingärtner S, Moeller S, Akçakaya M. Improved Simultaneous Multi-slice imaging with Composition of k-space Interpolations (SMS-COOKIE) for myocardial T1 mapping. PLoS One 2023; 18:e0283972. [PMID: 37478080 PMCID: PMC10361528 DOI: 10.1371/journal.pone.0283972] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2022] [Accepted: 03/21/2023] [Indexed: 07/23/2023] Open
Abstract
The aim of this study is to develop and evaluate a regularized Simultaneous Multi-Slice (SMS) reconstruction method for improved Cardiac Magnetic Resonance Imaging (CMR). The proposed reconstruction method, SMS with COmpOsition of k-space IntErpolations (SMS-COOKIE) combines the advantages of Iterative Self-consistent Parallel Imaging Reconstruction (SPIRiT) and split slice-Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA), while allowing regularization for further noise reduction. The proposed SMS-COOKIE was implemented with and without regularization, and validated using a Saturation Pulse-Prepared Heart rate Independent inversion REcovery (SAPPHIRE) myocardial T1 mapping sequence. The performance of the proposed reconstruction method was compared to ReadOut (RO)-SENSE-GRAPPA and split slice-GRAPPA, on both retrospectively and prospectively three-fold SMS-accelerated data with an additional two-fold in-plane acceleration. All SMS reconstruction methods yielded similar T1 values compared to single band imaging. SMS-COOKIE showed lower spatial variability in myocardial T1 with significant improvement over RO-SENSE-GRAPPA and split slice-GRAPPA (P < 10-4). The proposed method with additional locally low rank (LLR) regularization reduced the spatial variability, again with significant improvement over RO-SENSE-GRAPPA and split slice-GRAPPA (P < 10-4). In conclusion, improved reconstruction quality was achieved with the proposed SMS-COOKIE, which also provided lower spatial variability with significant improvement over split slice-GRAPPA.
Collapse
Affiliation(s)
- Ömer Burak Demirel
- Electrical and Computer Engineering, University of Minnesota, Minneapolis, Minnesota, United States of America
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, United States of America
| | - Sebastian Weingärtner
- Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands
| | - Steen Moeller
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, United States of America
| | - Mehmet Akçakaya
- Electrical and Computer Engineering, University of Minnesota, Minneapolis, Minnesota, United States of America
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, United States of America
| |
Collapse
|
37
|
Liu Y, Hamilton J, Jiang Y, Seiberlich N. Assessment of MRF for simultaneous T 1 and T 2 quantification and water-fat separation in the liver at 0.55 T. MAGMA (NEW YORK, N.Y.) 2023; 36:513-523. [PMID: 36574163 PMCID: PMC10293475 DOI: 10.1007/s10334-022-01057-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/19/2022] [Revised: 11/10/2022] [Accepted: 12/13/2022] [Indexed: 12/28/2022]
Abstract
OBJECTIVE The goal of this work was to assess the feasibility of performing MRF in the liver on a 0.55 T scanner and to examine the feasibility of water-fat separation using rosette MRF at 0.55 T. MATERIALS AND METHODS Spiral and rosette MRF sequences were implemented on a commercial 0.55 T scanner. The accuracy of both sequences in T1 and T2 quantification was validated in the ISMRM/NIST system phantom. The efficacy of rosette MRF in water-fat separation was evaluated in simulations and water/oil phantoms. Both spiral and rosette MRF were performed in the liver of healthy subjects. RESULTS In the ISMRM/NIST phantom, both spiral and rosette MRF achieved good agreement with reference values in T1 and T2 measurements. In addition, rosette MRF enables water-fat separation and can generate water- and fat- specific T1 maps, T2 maps, and proton density images from the same dataset for a spatial resolution of 1.56 × 1.56 × 5mm3 within the acquisition time of 15 s. CONCLUSION It is feasible to measure T1 and T2 simultaneously in the liver using MRF on a 0.55 T system with lower performance gradients compared to state-of-the-art 1.5 T and 3 T systems within an acquisition time of 15 s. In addition, rosette MRF enables water-fat separation along with T1 and T2 quantification with no time penalty.
Collapse
Affiliation(s)
- Yuchi Liu
- Department of Radiology, University of Michigan, 1150 West Medical Center Drive, Ann Arbor, MI, 48109, USA.
| | - Jesse Hamilton
- Department of Radiology, University of Michigan, 1150 West Medical Center Drive, Ann Arbor, MI, 48109, USA
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
| | - Yun Jiang
- Department of Radiology, University of Michigan, 1150 West Medical Center Drive, Ann Arbor, MI, 48109, USA
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
| | - Nicole Seiberlich
- Department of Radiology, University of Michigan, 1150 West Medical Center Drive, Ann Arbor, MI, 48109, USA
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
| |
Collapse
|
38
|
Meyer NK, Kang D, Black DF, Campeau NG, Welker KM, Gray EM, In MH, Shu Y, Huston III J, Bernstein MA, Trzasko JD. Enhanced clinical task-based fMRI metrics through locally low-rank denoising of complex-valued data. Neuroradiol J 2023; 36:273-288. [PMID: 36063799 PMCID: PMC10268095 DOI: 10.1177/19714009221122171] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
OBJECTIVE This study investigates a locally low-rank (LLR) denoising algorithm applied to source images from a clinical task-based functional MRI (fMRI) exam before post-processing for improving statistical confidence of task-based activation maps. METHODS Task-based motor and language fMRI was obtained in eleven healthy volunteers under an IRB approved protocol. LLR denoising was then applied to raw complex-valued image data before fMRI processing. Activation maps generated from conventional non-denoised (control) data were compared with maps derived from LLR-denoised image data. Four board-certified neuroradiologists completed consensus assessment of activation maps; region-specific and aggregate motor and language consensus thresholds were then compared with nonparametric statistical tests. Additional evaluation included retrospective truncation of exam data without and with LLR denoising; a ROI-based analysis tracked t-statistics and temporal SNR (tSNR) as scan durations decreased. A test-retest assessment was performed; retest data were matched with initial test data and compared for one subject. RESULTS fMRI activation maps generated from LLR-denoised data predominantly exhibited statistically significant (p = 4.88×10-4 to p = 0.042; one p = 0.062) increases in consensus t-statistic thresholds for motor and language activation maps. Following data truncation, LLR data showed task-specific increases in t-statistics and tSNR respectively exceeding 20 and 50% compared to control. LLR denoising enabled truncation of exam durations while preserving cluster volumes at fixed thresholds. Test-retest showed variable activation with LLR data thresholded higher in matching initial test data. CONCLUSION LLR denoising affords robust increases in t-statistics on fMRI activation maps compared to routine processing, and offers potential for reduced scan duration while preserving map quality.
Collapse
Affiliation(s)
- Nolan K Meyer
- Mayo Clinic Graduate School of Biomedical Sciences, Rochester, MN, USA
| | - Daehun Kang
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | - David F Black
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | | | - Kirk M Welker
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | - Erin M Gray
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | - Myung-Ho In
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | - Yunhong Shu
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | | | | | | |
Collapse
|
39
|
Daniel G, Meirav G, Noam O, Tamar BK, Dvir R, Ricardo O, Noam BE. Fast and accurate T 2 mapping using Bloch simulations and low-rank plus sparse matrix decomposition. Magn Reson Imaging 2023; 98:66-75. [PMID: 36649808 DOI: 10.1016/j.mri.2023.01.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Accepted: 01/08/2023] [Indexed: 01/15/2023]
Abstract
PURPOSE MRI's T2 relaxation time is one of the key contrast mechanisms for clinical diagnosis and prognosis of pathologies. Mapping this relaxation time, however, involves extensive scan times, which are needed to collect quantitative data, thereby impeding its integration into clinical routine. This study employs a low-rank plus sparse (L + S) signal decomposition approach in order to reconstruct accurate T2-maps from highly undersampled multi-echo spin-echo (MESE) MRI data. METHODS Two new algorithms are presented: the first uses standard L + S approach, where both L and S are iteratively updated. The second technique, dubbed SPArse and fixed RanK (SPARK), uses a fixed-rank L, under the assumption that most MESE information is found in the L component and that this rank can be pre-calculated. The utility of these new techniques is demonstrated on in vivo brain and calf data at x2 to x6 acceleration factors. RESULTS Accelerated T2 maps showed improved accuracy compared to fully sampled ground truth maps, when using L + S and SPARK techniques vis-à-vis standard GRAPPA acceleration. CONCLUSION SPARK provides accurate T2 maps with increased robustness to the selection of reconstruction parameters making it suitable to a wide range of applications and facilitating the use of quantitative T2 information in clinical settings.
Collapse
Affiliation(s)
- Grzeda Daniel
- Department of Biomedical Engineering, Tel-Aviv University, Tel Aviv, Israel
| | - Galun Meirav
- Department of Computer Science and Applied Mathematics, Weitzman Institute of Science, Rehovot, Israel
| | - Omer Noam
- Department of Biomedical Engineering, Tel-Aviv University, Tel Aviv, Israel
| | | | - Radunsky Dvir
- Department of Biomedical Engineering, Tel-Aviv University, Tel Aviv, Israel
| | - Otazo Ricardo
- Departments of Medical Physics and Radiology, Memorial Sloan Kettering Cancer Center, New York, NY 10016, USA
| | - Ben-Eliezer Noam
- Department of Biomedical Engineering, Tel-Aviv University, Tel Aviv, Israel; Sagol School of Neuroscience, Tel-Aviv University, Tel-Aviv, Israel; Center for Advanced Imaging Innovation and Research (CAI2R), New-York University Langone Medical Center, New York, NY 10016, USA.
| |
Collapse
|
40
|
Slavkova KP, DiCarlo JC, Wadhwa V, Kumar S, Wu C, Virostko J, Yankeelov TE, Tamir JI. An untrained deep learning method for reconstructing dynamic MR images from accelerated model-based data. Magn Reson Med 2023; 89:1617-1633. [PMID: 36468624 PMCID: PMC9892348 DOI: 10.1002/mrm.29547] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2022] [Revised: 11/09/2022] [Accepted: 11/15/2022] [Indexed: 12/09/2022]
Abstract
PURPOSE To implement physics-based regularization as a stopping condition in tuning an untrained deep neural network for reconstructing MR images from accelerated data. METHODS The ConvDecoder (CD) neural network was trained with a physics-based regularization term incorporating the spoiled gradient echo equation that describes variable-flip angle data. Fully-sampled variable-flip angle k-space data were retrospectively accelerated by factors of R = {8, 12, 18, 36} and reconstructed with CD, CD with the proposed regularization (CD + r), locally low-rank (LR) reconstruction, and compressed sensing with L1-wavelet regularization (L1). Final images from CD + r training were evaluated at the "argmin" of the regularization loss; whereas the CD, LR, and L1 reconstructions were chosen optimally based on ground truth data. The performance measures used were the normalized RMS error, the concordance correlation coefficient, and the structural similarity index. RESULTS The CD + r reconstructions, chosen using the stopping condition, yielded structural similarity indexs that were similar to the CD (p = 0.47) and LR structural similarity indexs (p = 0.95) across R and that were significantly higher than the L1 structural similarity indexs (p = 0.04). The concordance correlation coefficient values for the CD + r T1 maps across all R and subjects were greater than those corresponding to the L1 (p = 0.15) and LR (p = 0.13) T1 maps, respectively. For R ≥ 12 (≤4.2 min scan time), L1 and LR T1 maps exhibit a loss of spatially refined details compared to CD + r. CONCLUSION The use of an untrained neural network together with a physics-based regularization loss shows promise as a measure for determining the optimal stopping point in training without relying on fully-sampled ground truth data.
Collapse
Affiliation(s)
| | - Julie C. DiCarlo
- The Oden Institute for Computational Engineering and Sciences, The University of Texas at Austin, Austin, USA
- Livestrong Cancer Institutes, Dell Medical School, The University of Texas at Austin, Austin, TX USA
| | - Viraj Wadhwa
- Chandra Family Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, TX USA
| | - Sidharth Kumar
- Chandra Family Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, TX USA
| | - Chengyue Wu
- The Oden Institute for Computational Engineering and Sciences, The University of Texas at Austin, Austin, USA
| | - John Virostko
- The Oden Institute for Computational Engineering and Sciences, The University of Texas at Austin, Austin, USA
- Livestrong Cancer Institutes, Dell Medical School, The University of Texas at Austin, Austin, TX USA
- Department of Diagnostic Medicine, Dell Medical School, The University of Texas at Austin, Austin, TX USA
- Department of Oncology, Dell Medical School, The University of Texas at Austin, Austin, TX USA
| | - Thomas E. Yankeelov
- The Oden Institute for Computational Engineering and Sciences, The University of Texas at Austin, Austin, USA
- Livestrong Cancer Institutes, Dell Medical School, The University of Texas at Austin, Austin, TX USA
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, USA
- Department of Diagnostic Medicine, Dell Medical School, The University of Texas at Austin, Austin, TX USA
- Department of Oncology, Dell Medical School, The University of Texas at Austin, Austin, TX USA
| | - Jonathan I. Tamir
- The Oden Institute for Computational Engineering and Sciences, The University of Texas at Austin, Austin, USA
- Chandra Family Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, TX USA
- Department of Diagnostic Medicine, Dell Medical School, The University of Texas at Austin, Austin, TX USA
| |
Collapse
|
41
|
Oscanoa JA, Middione MJ, Alkan C, Yurt M, Loecher M, Vasanawala SS, Ennis DB. Deep Learning-Based Reconstruction for Cardiac MRI: A Review. Bioengineering (Basel) 2023; 10:334. [PMID: 36978725 PMCID: PMC10044915 DOI: 10.3390/bioengineering10030334] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2023] [Revised: 03/03/2023] [Accepted: 03/03/2023] [Indexed: 03/09/2023] Open
Abstract
Cardiac magnetic resonance (CMR) is an essential clinical tool for the assessment of cardiovascular disease. Deep learning (DL) has recently revolutionized the field through image reconstruction techniques that allow unprecedented data undersampling rates. These fast acquisitions have the potential to considerably impact the diagnosis and treatment of cardiovascular disease. Herein, we provide a comprehensive review of DL-based reconstruction methods for CMR. We place special emphasis on state-of-the-art unrolled networks, which are heavily based on a conventional image reconstruction framework. We review the main DL-based methods and connect them to the relevant conventional reconstruction theory. Next, we review several methods developed to tackle specific challenges that arise from the characteristics of CMR data. Then, we focus on DL-based methods developed for specific CMR applications, including flow imaging, late gadolinium enhancement, and quantitative tissue characterization. Finally, we discuss the pitfalls and future outlook of DL-based reconstructions in CMR, focusing on the robustness, interpretability, clinical deployment, and potential for new methods.
Collapse
Affiliation(s)
- Julio A. Oscanoa
- Department of Bioengineering, Stanford University, Stanford, CA 94305, USA
- Department of Radiology, Stanford University, Stanford, CA 94305, USA
| | | | - Cagan Alkan
- Department of Electrical Engineering, Stanford University, Stanford, CA 94305, USA
| | - Mahmut Yurt
- Department of Electrical Engineering, Stanford University, Stanford, CA 94305, USA
| | - Michael Loecher
- Department of Radiology, Stanford University, Stanford, CA 94305, USA
| | | | - Daniel B. Ennis
- Department of Radiology, Stanford University, Stanford, CA 94305, USA
| |
Collapse
|
42
|
Zhang J, Spincemaille P, Zhang H, Nguyen TD, Li C, Li J, Kovanlikaya I, Sabuncu MR, Wang Y. LARO: Learned acquisition and reconstruction optimization to accelerate quantitative susceptibility mapping. Neuroimage 2023; 268:119886. [PMID: 36669747 PMCID: PMC10021353 DOI: 10.1016/j.neuroimage.2023.119886] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 12/12/2022] [Accepted: 01/16/2023] [Indexed: 01/19/2023] Open
Abstract
Quantitative susceptibility mapping (QSM) involves acquisition and reconstruction of a series of images at multi-echo time points to estimate tissue field, which prolongs scan time and requires specific reconstruction technique. In this paper, we present our new framework, called Learned Acquisition and Reconstruction Optimization (LARO), which aims to accelerate the multi-echo gradient echo (mGRE) pulse sequence for QSM. Our approach involves optimizing a Cartesian multi-echo k-space sampling pattern with a deep reconstruction network. Next, this optimized sampling pattern was implemented in an mGRE sequence using Cartesian fan-beam k-space segmenting and ordering for prospective scans. Furthermore, we propose to insert a recurrent temporal feature fusion module into the reconstruction network to capture signal redundancies along echo time. Our ablation studies show that both the optimized sampling pattern and proposed reconstruction strategy help improve the quality of the multi-echo image reconstructions. Generalization experiments show that LARO is robust on the test data with new pathologies and different sequence parameters. Our code is available at https://github.com/Jinwei1209/LARO-QSM.git.
Collapse
Affiliation(s)
- Jinwei Zhang
- Department of Biomedical Engineering, Cornell University, Ithaca, NY, USA; Department of Radiology, Weill Medical College of Cornell University, New York, NY, USA
| | - Pascal Spincemaille
- Department of Radiology, Weill Medical College of Cornell University, New York, NY, USA
| | - Hang Zhang
- Department of Radiology, Weill Medical College of Cornell University, New York, NY, USA; Department of Electrical and Computer Engineering, Cornell University, Ithaca, NY, USA
| | - Thanh D Nguyen
- Department of Radiology, Weill Medical College of Cornell University, New York, NY, USA
| | - Chao Li
- Department of Radiology, Weill Medical College of Cornell University, New York, NY, USA; Department of Applied Physics, Cornell University, Ithaca, NY, USA
| | - Jiahao Li
- Department of Biomedical Engineering, Cornell University, Ithaca, NY, USA; Department of Radiology, Weill Medical College of Cornell University, New York, NY, USA
| | - Ilhami Kovanlikaya
- Department of Radiology, Weill Medical College of Cornell University, New York, NY, USA
| | - Mert R Sabuncu
- Department of Radiology, Weill Medical College of Cornell University, New York, NY, USA; Department of Electrical and Computer Engineering, Cornell University, Ithaca, NY, USA
| | - Yi Wang
- Department of Biomedical Engineering, Cornell University, Ithaca, NY, USA; Department of Radiology, Weill Medical College of Cornell University, New York, NY, USA.
| |
Collapse
|
43
|
Lam F, Peng X, Liang ZP. High-Dimensional MR Spatiospectral Imaging by Integrating Physics-Based Modeling and Data-Driven Machine Learning: Current progress and future directions. IEEE SIGNAL PROCESSING MAGAZINE 2023; 40:101-115. [PMID: 37538148 PMCID: PMC10398845 DOI: 10.1109/msp.2022.3203867] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/05/2023]
Abstract
Magnetic resonance spectroscopic imaging (MRSI) offers a unique molecular window into the physiological and pathological processes in the human body. However, the applications of MRSI have been limited by a number of long-standing technical challenges due to high dimensionality and low signal-to-noise ratio (SNR). Recent technological developments integrating physics-based modeling and data-driven machine learning that exploit unique physical and mathematical properties of MRSI signals have demonstrated impressive performance in addressing these challenges for rapid, high-resolution, quantitative MRSI. This paper provides a systematic review of these progresses in the context of MRSI physics and offers perspectives on promising future directions.
Collapse
Affiliation(s)
- Fan Lam
- Department of Bioengineering, University of Illinois Urbana-Champaign, Urbana, IL, 61801 USA
- Beckman Institute for Advanced Science and Technology, Department of Electrical and Computer Engineering and Cancer Center at Illinois, University of Illinois Urbana-Champaign
| | - Xi Peng
- Department of Radiology, Mayo Clinic, Rochester, MN, 55905, USA
| | - Zhi-Pei Liang
- Beckman Institute for Advanced Science and Technology, Department of Electrical and Computer Engineering and Cancer Center at Illinois, University of Illinois Urbana-Champaign
| |
Collapse
|
44
|
Munoz C, Fotaki A, Botnar RM, Prieto C. Latest Advances in Image Acceleration: All Dimensions are Fair Game. J Magn Reson Imaging 2023; 57:387-402. [PMID: 36205716 PMCID: PMC10092100 DOI: 10.1002/jmri.28462] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Revised: 09/20/2022] [Accepted: 09/22/2022] [Indexed: 01/20/2023] Open
Abstract
Magnetic resonance imaging (MRI) is a versatile modality that can generate high-resolution images with a variety of tissue contrasts. However, MRI is a slow technique and requires long acquisition times, which increase with higher temporal and spatial resolution and/or when multiple contrasts and large volumetric coverage is required. In order to speedup MR data acquisition, several approaches have been introduced in the literature. Most of these techniques acquire less data than required and exploit intrinsic redundancies in the MR images to recover the information that was not sampled. This article presents a review of MR acquisition and reconstruction methods that have exploited redundancies in the temporal, spatial, and contrast/parametric dimensions to accelerate image data acquisition, focusing on cardiac and abdominal MR imaging applications. The review describes how each of these dimensions has been separately exploited for speeding up MR acquisition to then discuss more advanced techniques where multiple dimensions are exploited together for further reducing scan times. Finally, future directions for multidimensional image acceleration and remaining technical challenges are discussed. EVIDENCE LEVEL: 5 TECHNICAL EFFICACY: 1.
Collapse
Affiliation(s)
- Camila Munoz
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| | - Anastasia Fotaki
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| | - René M Botnar
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.,Escuela de Ingeniería, Pontificia Universidad Católica de Chile, Santiago, Chile.,Millenium Institute for Intelligent Healthcare Engineering iHEALTH, Santiago, Chile
| | - Claudia Prieto
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.,Escuela de Ingeniería, Pontificia Universidad Católica de Chile, Santiago, Chile.,Millenium Institute for Intelligent Healthcare Engineering iHEALTH, Santiago, Chile
| |
Collapse
|
45
|
Li H, Yang M, Kim JH, Zhang C, Liu R, Huang P, Liang D, Zhang X, Li X, Ying L. SuperMAP: Deep ultrafast MR relaxometry with joint spatiotemporal undersampling. Magn Reson Med 2023; 89:64-76. [PMID: 36128884 PMCID: PMC9617769 DOI: 10.1002/mrm.29411] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2022] [Revised: 07/19/2022] [Accepted: 07/25/2022] [Indexed: 11/09/2022]
Abstract
PURPOSE To develop an ultrafast and robust MR parameter mapping network using deep learning. THEORY AND METHODS We design a deep learning framework called SuperMAP that directly converts a series of undersampled (both in k-space and parameter-space) parameter-weighted images into several quantitative maps, bypassing the conventional exponential fitting procedure. We also present a novel technique to simultaneously reconstruct T1rho and T2 relaxation maps within a single scan. Full data were acquired and retrospectively undersampled for training and testing using traditional and state-of-the-art techniques for comparison. Prospective data were also collected to evaluate the trained network. The performance of all methods is evaluated using the parameter qualification errors and other metrics in the segmented regions of interest. RESULTS SuperMAP achieved accurate T1rho and T2 mapping with high acceleration factors (R = 24 and R = 32). It exploited both spatial and temporal information and yielded low error (normalized mean square error of 2.7% at R = 24 and 2.8% at R = 32) and high resemblance (structural similarity of 97% at R = 24 and 96% at R = 32) to the gold standard. The network trained with retrospectively undersampled data also works well for the prospective data (with a slightly lower acceleration factor). SuperMAP is also superior to conventional methods. CONCLUSION Our results demonstrate the feasibility of generating superfast MR parameter maps through very few undersampled parameter-weighted images. SuperMAP can simultaneously generate T1rho and T2 relaxation maps in a short scan time.
Collapse
Affiliation(s)
- Hongyu Li
- Electrical Engineering, University at Buffalo, State University of New York, Buffalo, NY, USA
| | - Mingrui Yang
- Program of Advanced Musculoskeletal Imaging (PAMI), Cleveland Clinic, Cleveland, Ohio, USA
| | - Jee Hun Kim
- Program of Advanced Musculoskeletal Imaging (PAMI), Cleveland Clinic, Cleveland, Ohio, USA
| | - Chaoyi Zhang
- Electrical Engineering, University at Buffalo, State University of New York, Buffalo, NY, USA
| | - Ruiying Liu
- Electrical Engineering, University at Buffalo, State University of New York, Buffalo, NY, USA
| | - Peizhou Huang
- Electrical Engineering, University at Buffalo, State University of New York, Buffalo, NY, USA
| | - Dong Liang
- Paul C. Lauterbur Research Center for Biomedical Imaging, Medical AI research center, SIAT, CAS, Shenzhen, China
| | - Xiaoliang Zhang
- Biomedical Engineering, University at Buffalo, State University at New York, Buffalo, NY, USA
| | - Xiaojuan Li
- Program of Advanced Musculoskeletal Imaging (PAMI), Cleveland Clinic, Cleveland, Ohio, USA
| | - Leslie Ying
- Electrical Engineering, University at Buffalo, State University of New York, Buffalo, NY, USA
- Biomedical Engineering, University at Buffalo, State University at New York, Buffalo, NY, USA
| |
Collapse
|
46
|
Demirel OB, Yaman B, Shenoy C, Moeller S, Weingärtner S, Akçakaya M. Signal intensity informed multi-coil encoding operator for physics-guided deep learning reconstruction of highly accelerated myocardial perfusion CMR. Magn Reson Med 2023; 89:308-321. [PMID: 36128896 PMCID: PMC9617789 DOI: 10.1002/mrm.29453] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2022] [Revised: 07/21/2022] [Accepted: 08/21/2022] [Indexed: 01/11/2023]
Abstract
PURPOSE To develop a physics-guided deep learning (PG-DL) reconstruction strategy based on a signal intensity informed multi-coil (SIIM) encoding operator for highly-accelerated simultaneous multislice (SMS) myocardial perfusion cardiac MRI (CMR). METHODS First-pass perfusion CMR acquires highly-accelerated images with dynamically varying signal intensity/SNR following the administration of a gadolinium-based contrast agent. Thus, using PG-DL reconstruction with a conventional multi-coil encoding operator leads to analogous signal intensity variations across different time-frames at the network output, creating difficulties in generalization for varying SNR levels. We propose to use a SIIM encoding operator to capture the signal intensity/SNR variations across time-frames in a reformulated encoding operator. This leads to a more uniform/flat contrast at the output of the PG-DL network, facilitating generalizability across time-frames. PG-DL reconstruction with the proposed SIIM encoding operator is compared to PG-DL with conventional encoding operator, split slice-GRAPPA, locally low-rank (LLR) regularized reconstruction, low-rank plus sparse (L + S) reconstruction, and regularized ROCK-SPIRiT. RESULTS Results on highly accelerated free-breathing first pass myocardial perfusion CMR at three-fold SMS and four-fold in-plane acceleration show that the proposed method improves upon the reconstruction methods use for comparison. Substantial noise reduction is achieved compared to split slice-GRAPPA, and aliasing artifacts reduction compared to LLR regularized reconstruction, L + S reconstruction and PG-DL with conventional encoding. Furthermore, a qualitative reader study indicated that proposed method outperformed all methods. CONCLUSION PG-DL reconstruction with the proposed SIIM encoding operator improves generalization across different time-frames /SNRs in highly accelerated perfusion CMR.
Collapse
Affiliation(s)
- Omer Burak Demirel
- Department of Electrical and Computer EngineeringUniversity of MinnesotaMinneapolisMinnesotaUSA,Center for Magnetic Resonance ResearchUniversity of MinnesotaMinneapolisMinnesotaUSA
| | - Burhaneddin Yaman
- Department of Electrical and Computer EngineeringUniversity of MinnesotaMinneapolisMinnesotaUSA,Center for Magnetic Resonance ResearchUniversity of MinnesotaMinneapolisMinnesotaUSA
| | - Chetan Shenoy
- Department of Medicine (Cardiology)University of MinnesotaMinneapolisMinnesotaUSA
| | - Steen Moeller
- Center for Magnetic Resonance ResearchUniversity of MinnesotaMinneapolisMinnesotaUSA
| | | | - Mehmet Akçakaya
- Department of Electrical and Computer EngineeringUniversity of MinnesotaMinneapolisMinnesotaUSA,Center for Magnetic Resonance ResearchUniversity of MinnesotaMinneapolisMinnesotaUSA
| |
Collapse
|
47
|
Menon RG, Zibetti MVW, Regatte RR. Data-driven optimization of sampling patterns for MR brain T 1ρ mapping. Magn Reson Med 2023; 89:205-216. [PMID: 36129110 PMCID: PMC10022748 DOI: 10.1002/mrm.29445] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Revised: 08/09/2022] [Accepted: 08/17/2022] [Indexed: 02/05/2023]
Abstract
PURPOSE The goal of this study was to apply a fast data-driven optimization algorithm, called bias-accelerated subset selection, for MR brain T1ρ mapping to generate optimized sampling patterns (SPs) for compressed sensing reconstruction of brain 3D-T1ρ MRI. METHODS Five healthy volunteers were recruited, and fully sampled Cartesian 3D-T1ρ MRIs were obtained. Variable density (VD) and Poisson disc (PD) undersampling was used as the input to SP optimization process. The reconstruction used 3 compressed sensing methods: spatiotemporal finite differences, low-rank plus sparse with spatial finite differences, and low rank. The performance of images and T1ρ maps using PD-SP and VD-SP and their optimized sampling patterns (PD-OSP and VD-OSP) were compared to the fully sampled reference using normalized root mean square error (NRMSE). RESULTS The VD-OSP with spatiotemporal finite differences reconstruction (NRMSE = 0.078) and the PD-OSP with spatiotemporal finite differences reconstruction (NRMSE = 0.079) at the highest acceleration factors (AF = 30) showed the largest improvement compared to the respective nonoptimized SPs (VD NRMSE = 0.087 and PD NRMSE = 0.149). Prospective undersampling was tested at AF = 4, with VD-OSP NRMSE = 0.057 versus PD-OSP NRMSE = 0.060, with optimized sampling performing better that input PD or VD sampling. For brain T1ρ mapping, the VD-OSP with low rank reconstruction for AFs <10 and VD-OSP with spatiotemporal finite differences for AFs >10 perform better. CONCLUSIONS The study demonstrated that the appropriate use of data-driven optimized sampling and suitable compressed sensing reconstruction technique can be employed to potentially accelerate 3D T1ρ mapping for brain imaging applications.
Collapse
Affiliation(s)
- Rajiv G Menon
- Center for Biomedical Imaging, New York University School of Medicine, New York, NY, USA
| | - Marcelo V W Zibetti
- Center for Biomedical Imaging, New York University School of Medicine, New York, NY, USA
| | - Ravinder R Regatte
- Center for Biomedical Imaging, New York University School of Medicine, New York, NY, USA
| |
Collapse
|
48
|
Otikovs M, Basak A, Frydman L. Spatiotemporal encoding MRI using subspace-constrained sampling and locally-low-rank regularization: Applications to diffusion weighted and diffusion kurtosis imaging of human brain and prostate. Magn Reson Imaging 2022; 94:151-160. [PMID: 36216145 DOI: 10.1016/j.mri.2022.09.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2022] [Revised: 09/21/2022] [Accepted: 09/28/2022] [Indexed: 06/16/2023]
Abstract
The benefits of performing locally low-rank (LLR) reconstructions on subsampled diffusion weighted and diffusion kurtosis imaging data employing spatiotemporal encoding (SPEN) methods, is investigated. SPEN allows for self-referenced correction of motion-induced phase errors in case of interleaved diffusion-oriented acquisitions, and allows one to overcome distortions otherwise observed along EPI's phase-encoded dimension. In combination with LLR-based reconstructions of the pooled imaging data and with a joint subsampling of b-weighted and interleaved images, additional improvements in terms of sensitivity as well as shortened acquisition times are demonstrated, without noticeable penalties. Details on how the LLR-regularized, subspace-constrained image reconstructions were adapted to SPEN are given; the improvements introduced by adopting these reconstruction frameworks for the accelerated acquisition of diffusivity and of kurtosis imaging data in both relatively homogeneous regions like the human brain and in more challenging regions like the human prostate, are presented and discussed within the context of similar efforts in the field.
Collapse
Affiliation(s)
- Martins Otikovs
- Department of Chemical and Biological Physics and Azrieli National Center for Brain Imaging, Weizmann Institute of Science, Rehovot, Israel
| | - Ankit Basak
- Department of Chemical and Biological Physics and Azrieli National Center for Brain Imaging, Weizmann Institute of Science, Rehovot, Israel
| | - Lucio Frydman
- Department of Chemical and Biological Physics and Azrieli National Center for Brain Imaging, Weizmann Institute of Science, Rehovot, Israel.
| |
Collapse
|
49
|
Eyre K, Lindsay K, Razzaq S, Chetrit M, Friedrich M. Simultaneous multi-parametric acquisition and reconstruction techniques in cardiac magnetic resonance imaging: Basic concepts and status of clinical development. Front Cardiovasc Med 2022; 9:953823. [PMID: 36277755 PMCID: PMC9582154 DOI: 10.3389/fcvm.2022.953823] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2022] [Accepted: 09/22/2022] [Indexed: 11/13/2022] Open
Abstract
Simultaneous multi-parametric acquisition and reconstruction techniques (SMART) are gaining attention for their potential to overcome some of cardiovascular magnetic resonance imaging's (CMR) clinical limitations. The major advantages of SMART lie within their ability to simultaneously capture multiple "features" such as cardiac motion, respiratory motion, T1/T2 relaxation. This review aims to summarize the overarching theory of SMART, describing key concepts that many of these techniques share to produce co-registered, high quality CMR images in less time and with less requirements for specialized personnel. Further, this review provides an overview of the recent developments in the field of SMART by describing how they work, the parameters they can acquire, their status of clinical testing and validation, and by providing examples for how their use can improve the current state of clinical CMR workflows. Many of the SMART are in early phases of development and testing, thus larger scale, controlled trials are needed to evaluate their use in clinical setting and with different cardiac pathologies.
Collapse
Affiliation(s)
- Katerina Eyre
- McGill University Health Centre, Montreal, QC, Canada,Department of Experimental Medicine, McGill University, Montreal, QC, Canada,*Correspondence: Katerina Eyre,
| | - Katherine Lindsay
- McGill University Health Centre, Montreal, QC, Canada,Department of Experimental Medicine, McGill University, Montreal, QC, Canada
| | - Saad Razzaq
- Department of Experimental Medicine, McGill University, Montreal, QC, Canada
| | - Michael Chetrit
- McGill University Health Centre, Montreal, QC, Canada,Department of Experimental Medicine, McGill University, Montreal, QC, Canada
| | - Matthias Friedrich
- McGill University Health Centre, Montreal, QC, Canada,Department of Experimental Medicine, McGill University, Montreal, QC, Canada
| |
Collapse
|
50
|
Hoh T, Vishnevskiy V, Polacin M, Manka R, Fuetterer M, Kozerke S. Free-breathing motion-informed locally low-rank quantitative 3D myocardial perfusion imaging. Magn Reson Med 2022; 88:1575-1591. [PMID: 35713206 PMCID: PMC9544898 DOI: 10.1002/mrm.29295] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2021] [Revised: 03/30/2022] [Accepted: 04/19/2022] [Indexed: 12/30/2022]
Abstract
PURPOSE To propose respiratory motion-informed locally low-rank reconstruction (MI-LLR) for robust free-breathing single-bolus quantitative 3D myocardial perfusion CMR imaging. Simulation and in-vivo results are compared to locally low-rank (LLR) and compressed sensing reconstructions (CS) for reference. METHODS Data were acquired using a 3D Cartesian pseudo-spiral in-out k-t undersampling scheme (R = 10) and reconstructed using MI-LLR, which encompasses two stages. In the first stage, approximate displacement fields are derived from an initial LLR reconstruction to feed a motion-compensated reference system to a second reconstruction stage, which reduces the rank of the inverse problem. For comparison, data were also reconstructed with LLR and frame-by-frame CS using wavelets as sparsifying transform ( ℓ 1 $$ {\ell}_1 $$ -wavelet). Reconstruction accuracy relative to ground truth was assessed using synthetic data for realistic ranges of breathing motion, heart rates, and SNRs. In-vivo experiments were conducted in healthy subjects at rest and during adenosine stress. Myocardial blood flow (MBF) maps were derived using a Fermi model. RESULTS Improved uniformity of MBF maps with reduced local variations was achieved with MI-LLR. For rest and stress, intra-volunteer variation of absolute and relative MBF was lower in MI-LLR (±0.17 mL/g/min [26%] and ±1.07 mL/g/min [33%]) versus LLR (±0.19 mL/g/min [28%] and ±1.22 mL/g/min [36%]) and versus ℓ 1 $$ {\ell}_1 $$ -wavelet (±1.17 mL/g/min [113%] and ±6.87 mL/g/min [115%]). At rest, intra-subject MBF variation was reduced significantly with MI-LLR. CONCLUSION The combination of pseudo-spiral Cartesian undersampling and dual-stage MI-LLR reconstruction improves free-breathing quantitative 3D myocardial perfusion CMR imaging under rest and stress condition.
Collapse
Affiliation(s)
- Tobias Hoh
- Institute for Biomedical EngineeringUniversity and ETH ZurichZurichSwitzerland
| | - Valery Vishnevskiy
- Institute for Biomedical EngineeringUniversity and ETH ZurichZurichSwitzerland
| | - Malgorzata Polacin
- Institute for Biomedical EngineeringUniversity and ETH ZurichZurichSwitzerland
- Institute of Diagnostic and Interventional RadiologyUniversity Hospital Zurich, University of ZurichZurichSwitzerland
| | - Robert Manka
- Institute for Biomedical EngineeringUniversity and ETH ZurichZurichSwitzerland
- Institute of Diagnostic and Interventional RadiologyUniversity Hospital Zurich, University of ZurichZurichSwitzerland
- Department of CardiologyUniversity Heart Center, University Hospital Zurich, University of ZurichZurichSwitzerland
| | | | - Sebastian Kozerke
- Institute for Biomedical EngineeringUniversity and ETH ZurichZurichSwitzerland
| |
Collapse
|