1
|
Regenberg MC, Wilhelmi M, Hilfiker A, Haverich A, Aper T. Development, comparative structural analysis, and first in vivo evaluation of acellular implanted highly compacted fibrin tubes for arterial bypass grafting. J Mech Behav Biomed Mater 2023; 148:106199. [PMID: 37922760 DOI: 10.1016/j.jmbbm.2023.106199] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Revised: 10/11/2023] [Accepted: 10/16/2023] [Indexed: 11/07/2023]
Abstract
The generation of small-caliber vascular grafts remains a significant challenge within the field of tissue engineering. In pursuit of this objective, fibrin has emerged as a promising scaffold material. However, its lack of biomechanical strength has limited its utility in the construction of tissue engineered vascular grafts. We have previously reported about the implementation of centrifugal casting molding to generate compacted fibrin tubes with a highly increased biomechanical strength. In this study, we conducted a structural analysis of compacted fibrin tubes using the open-source software Fiji/BoneJ. The primary aim was to validate the hypothesis that the compaction of fibrin leads to a more complex structure characterized by increased crosslinking of fibrin fibers. Structural analysis revealed a strong correlation between fibrin's structure and its biomechanical strength. Moreover, we enhanced fibrin compaction in a subsequent dehydration process, leading to a significant increase of biomechanical strength. Thus, the presented method in combination with an adequate imaging, e.g., micro-CT, has substantial potential as a powerful tool for quality assurance in the development of fibrin-based vascular grafts. To validate this concept, acellular highly compacted fibrin tubes were implanted as substitutes of a segment of the carotid artery in a sheep model (n = 4). After 6 months explanted segments exhibited distinct remodeling, transitioning into newly formed arteries.
Collapse
Affiliation(s)
- Marie-Claire Regenberg
- Department for Cardiothoracic-, Transplantation and Vascular Surgery, Division for Vascular and Endovascular Surgery, Hannover Medical School, Hannover, Germany
| | - Mathias Wilhelmi
- Lower Saxony Centre for Biomedical Engineering, Implant Research and Development (NIFE), Hannover, Germany; Department for Vascular and Endovascular Surgery, St. Bernward Hospital, Hildesheim, Germany
| | - Andres Hilfiker
- Leibniz Research Laboratories for Biotechnology and Artificial Organs, Medical School Hannover, Hannover, Germany
| | - Axel Haverich
- Department for Cardiothoracic-, Transplantation and Vascular Surgery, Division for Vascular and Endovascular Surgery, Hannover Medical School, Hannover, Germany; Lower Saxony Centre for Biomedical Engineering, Implant Research and Development (NIFE), Hannover, Germany
| | - Thomas Aper
- Department for Cardiothoracic-, Transplantation and Vascular Surgery, Division for Vascular and Endovascular Surgery, Hannover Medical School, Hannover, Germany; Lower Saxony Centre for Biomedical Engineering, Implant Research and Development (NIFE), Hannover, Germany.
| |
Collapse
|
2
|
Bertsch C, Maréchal H, Gribova V, Lévy B, Debry C, Lavalle P, Fath L. Biomimetic Bilayered Scaffolds for Tissue Engineering: From Current Design Strategies to Medical Applications. Adv Healthc Mater 2023; 12:e2203115. [PMID: 36807830 PMCID: PMC11469754 DOI: 10.1002/adhm.202203115] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Revised: 01/17/2023] [Indexed: 02/20/2023]
Abstract
Tissue damage due to cancer, congenital anomalies, and injuries needs new efficient treatments that allow tissue regeneration. In this context, tissue engineering shows a great potential to restore the native architecture and function of damaged tissues, by combining cells with specific scaffolds. Scaffolds made of natural and/or synthetic polymers and sometimes ceramics play a key role in guiding cell growth and formation of the new tissues. Monolayered scaffolds, which consist of uniform material structure, are reported as not being sufficient to mimic complex biological environment of the tissues. Osteochondral, cutaneous, vascular, and many other tissues all have multilayered structures, therefore multilayered scaffolds seem more advantageous to regenerate these tissues. In this review, recent advances in bilayered scaffolds design applied to regeneration of vascular, bone, cartilage, skin, periodontal, urinary bladder, and tracheal tissues are focused on. After a short introduction on tissue anatomy, composition and fabrication techniques of bilayered scaffolds are explained. Then, experimental results obtained in vitro and in vivo are described, and their limitations are given. Finally, difficulties in scaling up production of bilayer scaffolds and reaching the stage of clinical studies are discussed when multiple scaffold components are used.
Collapse
Affiliation(s)
- Christelle Bertsch
- Institut National de la Santé et de la Recherche MédicaleInserm UMR_S 1121 Biomaterials and BioengineeringCentre de Recherche en Biomédecine de Strasbourg1 rue Eugène BoeckelStrasbourg67000France
| | - Hélène Maréchal
- Service d'ORL et de Chirurgie Cervico‐FacialeHôpitaux Universitaires de Strasbourg1 avenue MolièreStrasbourg67200France
| | - Varvara Gribova
- Institut National de la Santé et de la Recherche MédicaleInserm UMR_S 1121 Biomaterials and BioengineeringCentre de Recherche en Biomédecine de Strasbourg1 rue Eugène BoeckelStrasbourg67000France
| | - Benjamin Lévy
- Institut National de la Santé et de la Recherche MédicaleInserm UMR_S 1121 Biomaterials and BioengineeringCentre de Recherche en Biomédecine de Strasbourg1 rue Eugène BoeckelStrasbourg67000France
| | - Christian Debry
- Institut National de la Santé et de la Recherche MédicaleInserm UMR_S 1121 Biomaterials and BioengineeringCentre de Recherche en Biomédecine de Strasbourg1 rue Eugène BoeckelStrasbourg67000France
- Service d'ORL et de Chirurgie Cervico‐FacialeHôpitaux Universitaires de Strasbourg1 avenue MolièreStrasbourg67200France
| | - Philippe Lavalle
- Institut National de la Santé et de la Recherche MédicaleInserm UMR_S 1121 Biomaterials and BioengineeringCentre de Recherche en Biomédecine de Strasbourg1 rue Eugène BoeckelStrasbourg67000France
| | - Léa Fath
- Institut National de la Santé et de la Recherche MédicaleInserm UMR_S 1121 Biomaterials and BioengineeringCentre de Recherche en Biomédecine de Strasbourg1 rue Eugène BoeckelStrasbourg67000France
- Service d'ORL et de Chirurgie Cervico‐FacialeHôpitaux Universitaires de Strasbourg1 avenue MolièreStrasbourg67200France
| |
Collapse
|
3
|
Bao L, Li C, Tang M, Chen L, Hong FF. Potential of a Composite Conduit with Bacterial Nanocellulose and Fish Gelatin for Application as Small-Diameter Artificial Blood Vessel. Polymers (Basel) 2022; 14:polym14204367. [PMID: 36297946 PMCID: PMC9610583 DOI: 10.3390/polym14204367] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2022] [Revised: 09/29/2022] [Accepted: 10/08/2022] [Indexed: 11/16/2022] Open
Abstract
Bacterial nanocellulose (BNC) has received great attention for application as an artificial blood vessel material. However, many results showed that pristine BNC could not perfectly meet all the demands of blood vessels, especially for rapid endothelialization. In order to improve the properties of small-caliber vessels, different concentrations of fish gelatin (Gel) were deposited into the 3D network tubes and their properties were explored. The BNC/Gel composite tubes were treated with glutaraldehyde to crosslink BNC and fish gelatin. Compared with pristine BNC tubes, the BNC/Gel tubes had a certain improvement in mechanical properties. In vitro cell culture demonstrated that the human endothelial cells (HUVECs) and human smooth muscle cells (HSMCs) planted on the internal walls of BNC/Gel tubes showed better adhesion, higher proliferation and differentiation potential, and a better anticoagulation property, as compared to the cells cultured on pristine BNC tubes. Whole-blood coagulation experiments showed that the BNC/Gel tube had better properties than the BNC tube, and the hemolysis rate of all samples was less than 1.0%, satisfying the international standards for medical materials. An increase in the content of fish gelatin also increased the mechanical properties and the biocompatibility of small-caliber vessels. Considering the properties of BNC/Gel tubes, 1.0 wt/v% was selected as the most appropriate concentration of fish gelatin for a composite.
Collapse
Affiliation(s)
- Luhan Bao
- State Key Laboratory of Biobased Material and Green Papermaking, Qilu University of Technology, Shandong Academy of Sciences, Jinan 250353, China
- Group of Microbiological Engineering and Biomedical Materials, College of Biological Science and Medical Engineering, Donghua University, North Ren Min Road 2999, Shanghai 201620, China
- Scientific Research Base of Bacterial Nanofiber Manufacturing and Composite Technology, China Textile Engineering Society, Shanghai 201620, China
| | - Can Li
- State Key Laboratory of Biobased Material and Green Papermaking, Qilu University of Technology, Shandong Academy of Sciences, Jinan 250353, China
| | - Man Tang
- Group of Microbiological Engineering and Biomedical Materials, College of Biological Science and Medical Engineering, Donghua University, North Ren Min Road 2999, Shanghai 201620, China
| | - Lin Chen
- Group of Microbiological Engineering and Biomedical Materials, College of Biological Science and Medical Engineering, Donghua University, North Ren Min Road 2999, Shanghai 201620, China
- Scientific Research Base of Bacterial Nanofiber Manufacturing and Composite Technology, China Textile Engineering Society, Shanghai 201620, China
- Correspondence: (L.C.); (F.F.H.)
| | - Feng F. Hong
- State Key Laboratory of Biobased Material and Green Papermaking, Qilu University of Technology, Shandong Academy of Sciences, Jinan 250353, China
- Group of Microbiological Engineering and Biomedical Materials, College of Biological Science and Medical Engineering, Donghua University, North Ren Min Road 2999, Shanghai 201620, China
- Scientific Research Base of Bacterial Nanofiber Manufacturing and Composite Technology, China Textile Engineering Society, Shanghai 201620, China
- Correspondence: (L.C.); (F.F.H.)
| |
Collapse
|
4
|
Mohapatra SR, Rama E, Melcher C, Call T, Al Enezy-Ulbrich MA, Pich A, Apel C, Kiessling F, Jockenhoevel S. From In Vitro to Perioperative Vascular Tissue Engineering: Shortening Production Time by Traceable Textile-Reinforcement. Tissue Eng Regen Med 2022; 19:1169-1184. [PMID: 36201158 PMCID: PMC9679079 DOI: 10.1007/s13770-022-00482-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Revised: 07/18/2022] [Accepted: 07/20/2022] [Indexed: 12/01/2022] Open
Abstract
Background: The production of tissue-engineered vascular graft (TEVG) usually involves a prolonged bioreactor cultivation period of up to several weeks to achieve maturation of extracellular matrix and sufficient mechanical strength. Therefore, we aimed to substantially shorten this conditioning time by combining a TEVG textile scaffold with a recently developed copolymer reinforced fibrin gel as a cell carrier. We further implemented our grafts with magnetic resonance imaging (MRI) contrast agents to allow the in-vitro monitoring of the TEVG’s remodeling process. Methods: Biodegradable polylactic-co-glycolic acid (PLGA) was electrospun onto a non-degradable polyvinylidene fluoride scaffold and molded along with copolymer-reinforced fibrin hydrogel and human arterial cells. Mechanical tests on the TEVGs were performed both instantly after molding and 4 days of bioreactor conditioning. The non-invasive in vitro monitoring of the PLGA degradation and the novel imaging of fluorinated thermoplastic polyurethane (19F-TPU) were performed using 7T MRI. Results: After 4 days of close loop bioreactor conditioning, 617 ± 85 mmHg of burst pressure was achieved, and advanced maturation of extracellular matrix (ECM) was observed by immunohistology, especially in regards to collagen and smooth muscle actin. The suture retention strength (2.24 ± 0.3 N) and axial tensile strength (2.45 ± 0.58 MPa) of the TEVGs achieved higher values than the native arteries used as control. The contrast agents labeling of the TEVGs allowed the monitorability of the PLGA degradation and enabled the visibility of the non-degradable textile component. Conclusion: Here, we present a concept for a novel textile-reinforced TEVG, which is successfully produced in 4 days of bioreactor conditioning, characterized by increased ECM maturation and sufficient mechanical strength. Additionally, the combination of our approach with non-invasive imaging provides further insights into TEVG’s clinical application. Supplementary Information The online version contains supplementary material available at 10.1007/s13770-022-00482-0.
Collapse
Affiliation(s)
- Saurav Ranjan Mohapatra
- Department of Biohybrid and Medical Textiles (BioTex), Center for Biohybrid Medical Systems (CBMS), Institute for Applied Medical Engineering, RWTH Aachen University, Forckenbeckstr. 55, 52074, Aachen, Germany
| | - Elena Rama
- Institute for Experimental Molecular Imaging, RWTH Aachen University, Forckenbeckstr. 55, 52074, Aachen, Germany
| | - Christoph Melcher
- Institute for Textile Technology, RWTH Aachen University, Otto-Blumenthal-Str. 1, 52074, Aachen, Germany
| | - Tobias Call
- Department of Biohybrid and Medical Textiles (BioTex), Center for Biohybrid Medical Systems (CBMS), Institute for Applied Medical Engineering, RWTH Aachen University, Forckenbeckstr. 55, 52074, Aachen, Germany
| | | | - Andrij Pich
- DWI-Leibniz Institute for Interactive Materials, RWTH Aachen University, Forckenbeckstr. 50, 52074, Aachen, Germany
| | - Christian Apel
- Department of Biohybrid and Medical Textiles (BioTex), Center for Biohybrid Medical Systems (CBMS), Institute for Applied Medical Engineering, RWTH Aachen University, Forckenbeckstr. 55, 52074, Aachen, Germany
| | - Fabian Kiessling
- Institute for Experimental Molecular Imaging, RWTH Aachen University, Forckenbeckstr. 55, 52074, Aachen, Germany
| | - Stefan Jockenhoevel
- Department of Biohybrid and Medical Textiles (BioTex), Center for Biohybrid Medical Systems (CBMS), Institute for Applied Medical Engineering, RWTH Aachen University, Forckenbeckstr. 55, 52074, Aachen, Germany.
| |
Collapse
|
5
|
Ryu DS, Won DS, Kim JW, Park Y, Kim SH, Kang JM, Zeng CH, Lim D, Choi H, Park JH. Efficacy of thermoplastic polyurethane and gelatin blended nanofibers covered stent graft in the porcine iliac artery. Sci Rep 2022; 12:16524. [PMID: 36192510 PMCID: PMC9529973 DOI: 10.1038/s41598-022-20950-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2022] [Accepted: 09/21/2022] [Indexed: 11/09/2022] Open
Abstract
Stent-grafts composed of expanded polytetrafluoroethylene (e-PTFE), polyethylene terephthalate (PET) and polyurethane (PU) are characterized by poor endothelialization, high modulus, and low compliance, leading to thrombosis and intimal hyperplasia. A composite synthetic/natural matrix is considered a promising alternative to conventional synthetic stent-grafts. This study aimed to investigate the efficacy of thermoplastic polyurethane (TPU) and gelatin (GL) blended nanofibers (NFs) covered stent-graft in the porcine iliac artery. Twelve pigs were randomly sacrificed 7 days (n = 6) and 28 days (n = 6) after stent-graft placement. The thrombogenicity score at 28 days was significantly increased compared at 7 days (p < 0.001). The thickness of neointimal hyperplasia, degree of inflammatory cell infiltration, and degree of collagen deposition were significantly higher at 28 days than at 7 days (all p < 0.001). The TPU and GL blended NFs-covered stent-grafts successfully maintained the patency for 28 days in the porcine iliac artery. Although thrombosis with neointimal tissue were observed, no subsequent occlusion of the stent-graft was noted until the end of the study. Composite synthetic/natural matrix-covered stent-grafts may be promising for prolonging stent-graft patency.
Collapse
Affiliation(s)
- Dae Sung Ryu
- Biomedical Engineering Research Center, Asan Institute for Life Sciences, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, Republic of Korea
| | - Dong-Sung Won
- Biomedical Engineering Research Center, Asan Institute for Life Sciences, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, Republic of Korea
| | - Ji Won Kim
- Biomedical Engineering Research Center, Asan Institute for Life Sciences, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, Republic of Korea
| | - Yubeen Park
- Biomedical Engineering Research Center, Asan Institute for Life Sciences, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, Republic of Korea
| | - Song Hee Kim
- Biomedical Engineering Research Center, Asan Institute for Life Sciences, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, Republic of Korea
| | - Jeon Min Kang
- Biomedical Engineering Research Center, Asan Institute for Life Sciences, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, Republic of Korea
| | - Chu Hui Zeng
- Biomedical Engineering Research Center, Asan Institute for Life Sciences, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, Republic of Korea
| | - Dohyung Lim
- Department of Mechanical Engineering, Sejong University, 209, Neungdong-ro, Gwangjin-gu, Seoul, 05006, Republic of Korea
| | - Hyun Choi
- Department of Mechanical Engineering, Sejong University, 209, Neungdong-ro, Gwangjin-gu, Seoul, 05006, Republic of Korea.
| | - Jung-Hoon Park
- Biomedical Engineering Research Center, Asan Institute for Life Sciences, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, Republic of Korea.
| |
Collapse
|
6
|
A Comparative Study of an Anti-Thrombotic Small-Diameter Vascular Graft with Commercially Available e-PTFE Graft in a Porcine Carotid Model. Tissue Eng Regen Med 2022; 19:537-551. [PMID: 35167044 PMCID: PMC9130378 DOI: 10.1007/s13770-021-00422-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2021] [Revised: 12/09/2021] [Accepted: 12/13/2021] [Indexed: 12/11/2022] Open
Abstract
Background: We have designed a reinforced drug-loaded vascular graft composed of polycaprolactone (PCL) and polydioxanone (PDO) via a combination of electrospinning/3D printing approaches. To evaluate its potential for clinical application, we compared the in vivo blood compatibility and performance of PCL/PDO + 10%DY grafts doped with an antithrombotic drug (dipyridamole) with a commercial expanded polytetrafluoroethylene (e-PTFE) graft in a porcine model. Methods: A total of 10 pigs (weight: 25–35 kg) were used in this study. We made a new 5-mm graft with PCL/PDO composite nanofiber via the electrospinning technique. We simultaneously implanted a commercially available e-PTFE graft (n = 5) and our PCL/PDO + 10%DY graft (n = 5) into the carotid arteries of the pigs. No anticoagulant/antiplatelet agent was administered during the follow-up period, and ultrasonography was performed weekly to confirm the patency of the two grafts in vivo. Four weeks later, we explanted and compared the performance of the two grafts by histological analysis and scanning electron microscopy (SEM). Results: No complications, such as sweating on the graft or significant bleeding from the needle hole site, were seen in the PCL/PDO + 10%DY graft immediately after implantation. Serial ultrasonographic examination and immunohistochemical analysis demonstrated that PCL/PDO + 10%DY grafts showed normal physiological blood flow and minimal lumen reduction, and pulsed synchronously with the native artery at 4 weeks after implantation. However, all e-PTFE grafts occluded within the study period. The luminal surface of the PCL/PDO + 10%DY graft in the transitional zone was fully covered with endothelial cells as observed by SEM. Conclusion: The PCL/PDO + 10%DY graft was well tolerated, and no adverse tissue reaction was observed in porcine carotid models during the short-term follow-up. Colonization of the graft by host endothelial and smooth muscle cells coupled with substantial extracellular matrix production marked the regenerative capability. Thus, this material may be an ideal substitute for vascular reconstruction and bypass surgeries. Long-term observations will be necessary to determine the anti-thrombotic and remodeling potential of this device. Supplementary Information The online version contains supplementary material available at 10.1007/s13770-021-00422-4.
Collapse
|
7
|
Ilyas RA, Zuhri MYM, Norrrahim MNF, Misenan MSM, Jenol MA, Samsudin SA, Nurazzi NM, Asyraf MRM, Supian ABM, Bangar SP, Nadlene R, Sharma S, Omran AAB. Natural Fiber-Reinforced Polycaprolactone Green and Hybrid Biocomposites for Various Advanced Applications. Polymers (Basel) 2022; 14:182. [PMID: 35012203 PMCID: PMC8747341 DOI: 10.3390/polym14010182] [Citation(s) in RCA: 73] [Impact Index Per Article: 24.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Revised: 10/30/2021] [Accepted: 11/10/2021] [Indexed: 02/07/2023] Open
Abstract
Recent developments within the topic of biomaterials has taken hold of researchers due to the mounting concern of current environmental pollution as well as scarcity resources. Amongst all compatible biomaterials, polycaprolactone (PCL) is deemed to be a great potential biomaterial, especially to the tissue engineering sector, due to its advantages, including its biocompatibility and low bioactivity exhibition. The commercialization of PCL is deemed as infant technology despite of all its advantages. This contributed to the disadvantages of PCL, including expensive, toxic, and complex. Therefore, the shift towards the utilization of PCL as an alternative biomaterial in the development of biocomposites has been exponentially increased in recent years. PCL-based biocomposites are unique and versatile technology equipped with several importance features. In addition, the understanding on the properties of PCL and its blend is vital as it is influenced by the application of biocomposites. The superior characteristics of PCL-based green and hybrid biocomposites has expanded their applications, such as in the biomedical field, as well as in tissue engineering and medical implants. Thus, this review is aimed to critically discuss the characteristics of PCL-based biocomposites, which cover each mechanical and thermal properties and their importance towards several applications. The emergence of nanomaterials as reinforcement agent in PCL-based biocomposites was also a tackled issue within this review. On the whole, recent developments of PCL as a potential biomaterial in recent applications is reviewed.
Collapse
Affiliation(s)
- R. A. Ilyas
- School of Chemical and Energy Engineering, Faculty of Engineering, Universiti Teknologi Malaysia (UTM), Johor Bahru 81310, Johor, Malaysia;
- Centre for Advanced Composite Materials (CACM), Universiti Teknologi Malaysia (UTM), Johor Bahru 81310, Johor, Malaysia
| | - M. Y. M. Zuhri
- Institute of Tropical Forestry and Forest Products (INTROP), Universiti Putra Malaysia (UPM), Serdang 43400, Selangor Darul Ehsan, Malaysia;
- Advanced Engineering Materials and Composites Research Centre (AEMC), Department of Mechanical and Manufacturing Engineering, Universiti Putra Malaysia (UPM), Serdang 43400, Selangor, Malaysia
| | - Mohd Nor Faiz Norrrahim
- Research Center for Chemical Defence, Universiti Pertahanan Nasional Malaysia, Kem Sungai Besi, Kuala Lumpur 57000, Malaysia;
| | - Muhammad Syukri Mohamad Misenan
- Department of Chemistry, College of Arts and Science, Davutpasa Campus, Yildiz Technical University, Esenler, Istanbul 34220, Turkey;
| | - Mohd Azwan Jenol
- Department of Bioprocess Technology, Faculty of Biotechnology and Biomolecular Sciences, Universiti Putra Malaysia (UPM), Serdang 43400, Selangor, Malaysia;
| | - Sani Amril Samsudin
- School of Chemical and Energy Engineering, Faculty of Engineering, Universiti Teknologi Malaysia (UTM), Johor Bahru 81310, Johor, Malaysia;
| | - N. M. Nurazzi
- Centre for Defence Foundation Studies, Universiti Pertahanan Nasional Malaysia (UPNM), Kem Perdana Sungai Besi, Kuala Lumpur 57000, Malaysia;
| | - M. R. M. Asyraf
- Institute of Energy Infrastructure, Universiti Tenaga Nasional, Jalan IKRAM-UNITEN, Kajang 43000, Selangor, Malaysia;
| | - A. B. M. Supian
- Institute of Tropical Forestry and Forest Products (INTROP), Universiti Putra Malaysia (UPM), Serdang 43400, Selangor Darul Ehsan, Malaysia;
| | - Sneh Punia Bangar
- Department of Food, Nutrition and Packaging Sciences, Clemson University, Clemson, SC 29631, USA;
| | - R. Nadlene
- Fakulti Kejuruteraan Mekanikal, Universiti Teknikal Malaysia Melaka, Melaka 76100, Malaysia;
| | - Shubham Sharma
- Department of Mechanical Engineering, IK Gujral Punjab Technical University, Jalandhar 144001, India;
| | - Abdoulhdi A. Borhana Omran
- Department of Mechanical Engineering, College of Engineering, Universiti Tenaga Nasional, Jalan Ikram-Uniten, Kajang 43000, Selangor, Malaysia;
- Department of Mechanical Engineering, College of Engineering Science & Technology, Sebha University, Sabha 00218, Libya
| |
Collapse
|
8
|
Feng ZG, Fang Z, Xing Y, Wang H, Geng X, Ye L, Zhang A, Gu Y. Remodeling of Structurally Reinforced (TPU+PCL/PCL)-Hep Electro-spun Small Diameter Bilayer Vascular Grafts Interposed in Rat Ab-dominal Aorta. Biomater Sci 2022; 10:4257-4270. [DOI: 10.1039/d1bm01653a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
As the thermoplastic polyurethane (TPU) elastomer possesses good biocompatibility and mechanical properties similar to native vascular tissues as well, it is intended to co-electrospin with poly(ε-caprolactone) (PCL) onto the outer...
Collapse
|
9
|
Zhang X, Meng Y, Gong B, Wang T, Lu Y, Zhang L, Xue J. Electrospun Nanofibers for Manipulating the Soft Tissue Regeneration. J Mater Chem B 2022; 10:7281-7308. [DOI: 10.1039/d2tb00609j] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Soft tissue damage is a common clinical problem that affects the lives of a large number of patients all over the world. It is of great importance to develop functional...
Collapse
|
10
|
Byrne O, Coulter F, Roche ET, O'Cearbhaill ED. In silico design of additively manufacturable composite synthetic vascular conduits and grafts with tuneable compliance. Biomater Sci 2021; 9:4343-4355. [PMID: 33724267 DOI: 10.1039/d0bm02169e] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Benchtop testing of endovascular medical devices under accurately simulated physiological conditions is a critical part of device evaluation prior to clinical assessment. Currently, glass, acrylic and silicone vascular models are predominantly used as anatomical simulator test beds for in vitro testing. However, most current models lack the ability to mimic the non-linear radial compliance of native vessels and are typically limited to being compliance-matched at a single mean pressure comparison point or not at all. Hence, a degree of caution needs to be shown when analysing results from such models under simulated physiological or pathophysiological conditions. Similarly, the clinical translation of proposed biomimetic compliance-matched vascular grafts has undoubtedly been curtailed due to performance and material limitations. Here, we propose a new design for synthetic vessels where compliance can be precisely modulated across a wide physiological pressure range by customising design parameters. Building on previously demonstrated methods of 3D printing composite compliant cylindrical structures, we demonstrate proof of principle in creating composite vascular constructs designed via a finite element model. Our constructs are 3D printable and consist of a soft silicone matrix with embedded polyurethane fibres. The fibre layer consists of circumferential sinusoidal waves with an amplitude that can be altered to result in tuneable internal radial compliances of 5.2-15.9%/mmHg × 10-2 at a mean pressure of 100 mmHg. Importantly, the design presented here allows preservation of the non-linear exponentially decaying compliance curve of native arteries and veins with an increasing mean pressure. This model offers a design toolbox for 3D printable vascular models that offer biomimetic compliance. The robust nature of this model will lead to rapidly accelerating the design process for biomimetic vascular anatomical simulators, lumped parameter model flow loops, endovascular device benchtop testbeds, and compliance-matched synthetic grafts.
Collapse
Affiliation(s)
- Oisín Byrne
- School of Mechanical and Materials Engineering, UCD Centre for Biomedical Engineering, University College Dublin, Belfield, Ireland and CÚRAM, the SFI Research Centre for Medical Devices, Ireland
| | - Fergal Coulter
- School of Mechanical and Materials Engineering, UCD Centre for Biomedical Engineering, University College Dublin, Belfield, Ireland and Complex Materials, Department of Materials, ETH Zurich, Zurich, Switzerland
| | - Ellen T Roche
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA, USA and Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Eoin D O'Cearbhaill
- School of Mechanical and Materials Engineering, UCD Centre for Biomedical Engineering, University College Dublin, Belfield, Ireland and CÚRAM, the SFI Research Centre for Medical Devices, Ireland
| |
Collapse
|
11
|
Zhu J, Wang Y, Zhong L, Pan F, Wang J. Advances in tissue engineering of vasculature through three-dimensional bioprinting. Dev Dyn 2021; 250:1717-1738. [PMID: 34115420 DOI: 10.1002/dvdy.385] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2020] [Revised: 05/07/2021] [Accepted: 06/03/2021] [Indexed: 02/05/2023] Open
Abstract
BACKGROUND A significant challenge facing tissue engineering is the fabrication of vasculature constructs which contains vascularized tissue constructs to recapitulate viable, complex and functional organs or tissues, and free-standing vascular structures potentially providing clinical applications in the future. Three-dimensional (3D) bioprinting has emerged as a promising technology, possessing a number of merits that other conventional biofabrication methods do not have. Over the last decade, 3D bioprinting has contributed a variety of techniques and strategies to generate both vascularized tissue constructs and free-standing vascular structures. RESULTS This review focuses on different strategies to print two kinds of vasculature constructs, namely vascularized tissue constructs and vessel-like tubular structures, highlighting the feasibility and shortcoming of the current methods for vasculature constructs fabrication. Generally, both direct printing and indirect printing can be employed in vascularized tissue engineering. Direct printing allows for structural fabrication with synchronous cell seeding, while indirect printing is more effective in generating complex architecture. During the fabrication process, 3D bioprinting techniques including extrusion bioprinting, inkjet bioprinting and light-assisted bioprinting should be selectively implemented to exert advantages and obtain the desirable tissue structure. Also, appropriate cells and biomaterials matter a lot to match various bioprinting techniques and thus achieve successful fabrication of specific vasculature constructs. CONCLUSION The 3D bioprinting has been developed to help provide various fabrication techniques, devoting to producing structurally stable, physiologically relevant, and biologically appealing constructs. However, although the optimization of biomaterials and innovation of printing strategies may improve the fabricated vessel-like structures, 3D bioprinting is still in the infant period and has a great gap between in vitro trials and in vivo applications. The article reviews the present achievement of 3D bioprinting in generating vasculature constructs and also provides perspectives on future directions of advanced vasculature constructs fabrication.
Collapse
Affiliation(s)
- Junjin Zhu
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China.,Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Yuting Wang
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China.,Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Linna Zhong
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China.,Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Fangwei Pan
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China.,Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Jian Wang
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China.,Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| |
Collapse
|
12
|
Zhang B, Xu Y, Ma S, Wang L, Liu C, Xu W, Shi J, Qiao W, Yang H. Small-diameter polyurethane vascular graft with high strength and excellent compliance. J Mech Behav Biomed Mater 2021; 121:104614. [PMID: 34091151 DOI: 10.1016/j.jmbbm.2021.104614] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Revised: 05/23/2021] [Accepted: 05/27/2021] [Indexed: 11/30/2022]
Abstract
In this study, a polyurethane vascular graft with excellent strength and compliance for clinical application was designed and fabricated by preparing three small-diameter vascular graft layers via the textile techniques of wet spinning and knitting. The polyurethane filament that was fabricated by wet spinning formed the inner layer. The polyurethane tubular fabric was used as the middle layer. The outer layer was prepared by spraying polyurethane solution. The three layers of the polyurethane vascular graft have uniform wall thickness, high strength, excellent compliance, and good puncture resistance compared with clinical poly(ethylene terephthalate) (PET) and expanded polytetrafluoroethylene (ePTFE) vascular graft. Therefore, these layers can have potential clinical applications in the replacement of the conventional artificial vascular graft prepared from PET and ePTFE.
Collapse
Affiliation(s)
- Baocheng Zhang
- Department of Orthopaedics, General Hospital of Central Theater Command of PLA, Wuhan, 430070, PR China
| | - Yuan Xu
- Key Laboratory of Green Processing and Functional New Textile Materials of Ministry of Education, Wuhan Textile University, Wuhan, 430200, PR China
| | - Sitian Ma
- Key Laboratory of Green Processing and Functional New Textile Materials of Ministry of Education, Wuhan Textile University, Wuhan, 430200, PR China; College of Material Science and Engineering, Wuhan Textile University, Wuhan, 430200, PR China
| | - Linfeng Wang
- Key Laboratory of Green Processing and Functional New Textile Materials of Ministry of Education, Wuhan Textile University, Wuhan, 430200, PR China; College of Material Science and Engineering, Wuhan Textile University, Wuhan, 430200, PR China
| | - Changjun Liu
- Key Laboratory of Green Processing and Functional New Textile Materials of Ministry of Education, Wuhan Textile University, Wuhan, 430200, PR China; College of Material Science and Engineering, Wuhan Textile University, Wuhan, 430200, PR China
| | - Weilin Xu
- Key Laboratory of Green Processing and Functional New Textile Materials of Ministry of Education, Wuhan Textile University, Wuhan, 430200, PR China
| | - Jiawei Shi
- Department of Cardiovascular Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, PR China
| | - Weihua Qiao
- Department of Cardiovascular Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, PR China.
| | - Hongjun Yang
- Key Laboratory of Green Processing and Functional New Textile Materials of Ministry of Education, Wuhan Textile University, Wuhan, 430200, PR China; College of Material Science and Engineering, Wuhan Textile University, Wuhan, 430200, PR China.
| |
Collapse
|
13
|
Abstract
Tissue engineering is one of the most promising scientific breakthroughs of the late 20th century. Its objective is to produce in vitro tissues or organs to repair and replace damaged ones using various techniques, biomaterials, and cells. Tissue engineering emerged to substitute the use of native autologous tissues, whose quantities are sometimes insufficient to correct the most severe pathologies. Indeed, the patient’s health status, regulations, or fibrotic scars at the site of the initial biopsy limit their availability, especially to treat recurrence. This new technology relies on the use of biomaterials to create scaffolds on which the patient’s cells can be seeded. This review focuses on the reconstruction, by tissue engineering, of two types of tissue with tubular structures: vascular and urological grafts. The emphasis is on self-assembly methods which allow the production of tissue/organ substitute without the use of exogenous material, with the patient’s cells producing their own scaffold. These continuously improved techniques, which allow rapid graft integration without immune rejection in the treatment of severely burned patients, give hope that similar results will be observed in the vascular and urological fields.
Collapse
|
14
|
Sohn SH, Kim TH, Kim TS, Min TJ, Lee JH, Yoo SM, Kim JW, Lee JE, Kim CH, Park SH, Jo WM. Evaluation of 3D Templated Synthetic Vascular Graft Compared with Standard Graft in a Rat Model: Potential Use as an Artificial Vascular Graft in Cardiovascular Disease. MATERIALS 2021; 14:ma14051239. [PMID: 33807950 PMCID: PMC7962035 DOI: 10.3390/ma14051239] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/27/2021] [Revised: 02/25/2021] [Accepted: 03/01/2021] [Indexed: 12/03/2022]
Abstract
Although the number of vascular surgeries using vascular grafts is increasing, they are limited by vascular graft-related complications and size discrepancy. Current efforts to develop the ideal synthetic vascular graft for clinical application using tissue engineering or 3D printing are far from satisfactory. Therefore, we aimed to re-design the vascular graft with modified materials and 3D printing techniques and also demonstrated the improved applications of our new vascular graft clinically. We designed the 3D printed polyvinyl alcohol (PVA) templates according to the vessel size and shape, and these were dip-coated with salt-suspended thermoplastic polyurethane (TPU). Next, the core template was removed to obtain a customized porous TPU graft. The mechanical testing and cytotoxicity studies of the new synthetic 3D templated vascular grafts (3DT) were more appropriate compared with commercially available polytetrafluoroethylene (PTFE) grafts (ePTFE; standard graft, SG) for clinical use. Finally, we performed implantation of the 3DTs and SGs into the rat abdominal aorta as a patch technique. Four groups of the animal model (SG_7 days, SG_30 days, 3DT_7 days, and 3DT_30 days) were enrolled in this study. The abdominal aorta was surgically opened and sutured with SG or 3DT with 8/0 Prolene. The degree of endothelial cell activation, neovascularization, thrombus formation, calcification, inflammatory infiltrates, and fibrosis were analyzed histopathologically. There was significantly decreased thrombogenesis in the group treated with the 3DT for 30 days compared with the group treated with the SG for 7 and 30 days, and the 3DT for 7 days. In addition, the group treated with the 3DT for 30 days may also have shown increased postoperative endothelialization in the early stages. In conclusion, this study suggests the possibility of using the 3DT as an SG substitute in vascular surgery.
Collapse
Affiliation(s)
- Sung-Hwa Sohn
- Department of Thoracic & Cardiovascular Surgery, Korea University Ansan Hospital, Korea University College of Medicine, Ansan 15355, Korea; (S.-H.S.); (T.-S.K.); (S.-M.Y.)
| | - Tae-Hee Kim
- Advanced Textile R&D Department, Korea Institute of Industrial Technology, Ansan 15588, Korea; (T.-H.K.); (J.-E.L.); (C.-H.K.)
| | - Tae-Sik Kim
- Department of Thoracic & Cardiovascular Surgery, Korea University Ansan Hospital, Korea University College of Medicine, Ansan 15355, Korea; (S.-H.S.); (T.-S.K.); (S.-M.Y.)
| | - Too-Jae Min
- Department of Anesthesiology and Pain Medicine, Korea University Ansan Hospital, Korea University College of Medicine, Ansan 15355, Korea; (T.-J.M.); (J.-W.K.)
| | - Ju-Han Lee
- Department of Pathology, Korea University Ansan Hospital, Korea University College of Medicine, Ansan 15355, Korea;
| | - Sung-Mook Yoo
- Department of Thoracic & Cardiovascular Surgery, Korea University Ansan Hospital, Korea University College of Medicine, Ansan 15355, Korea; (S.-H.S.); (T.-S.K.); (S.-M.Y.)
| | - Ji-Won Kim
- Department of Anesthesiology and Pain Medicine, Korea University Ansan Hospital, Korea University College of Medicine, Ansan 15355, Korea; (T.-J.M.); (J.-W.K.)
| | - Ji-Eun Lee
- Advanced Textile R&D Department, Korea Institute of Industrial Technology, Ansan 15588, Korea; (T.-H.K.); (J.-E.L.); (C.-H.K.)
| | - Chae-Hwa Kim
- Advanced Textile R&D Department, Korea Institute of Industrial Technology, Ansan 15588, Korea; (T.-H.K.); (J.-E.L.); (C.-H.K.)
| | - Suk-Hee Park
- School of Mechanical Engineering, Pusan National University, 2 Busandaehak-ro, 63 Beon-gil, Geumjeong-gu, Busan 46241, Korea
- Correspondence: (S.-H.P.); (W.-M.J.)
| | - Won-Min Jo
- Department of Thoracic & Cardiovascular Surgery, Korea University Ansan Hospital, Korea University College of Medicine, Ansan 15355, Korea; (S.-H.S.); (T.-S.K.); (S.-M.Y.)
- Correspondence: (S.-H.P.); (W.-M.J.)
| |
Collapse
|
15
|
Khademolqorani S, Tavanai H, Chronakis IS, Boisen A, Ajalloueian F. The determinant role of fabrication technique in final characteristics of scaffolds for tissue engineering applications: A focus on silk fibroin-based scaffolds. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021; 122:111867. [PMID: 33641889 DOI: 10.1016/j.msec.2021.111867] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/11/2020] [Revised: 01/04/2021] [Accepted: 01/06/2021] [Indexed: 02/05/2023]
Abstract
3D scaffolds are in the center of attention for tissue engineering applications. Whilst many studies have focused on the biological properties of scaffolds, less attention has been paid to meeting the biomechanics of the target tissues. In this work, we show how using the same original biomaterial, but different fabrication techniques can lead to a broad range of structural, mechanical, and biological characteristics. Starting with silk fibroin filament as our base biomaterial, we employed electrospinning, film casting, and weft knitting as different scaffold fabrication techniques. Among these three, the weft knit scaffold showed outstanding cell-scaffold interaction including full 3D cell attachment, complete cell coverage around individual filaments, and in-depth cell infiltration. Post-fabrication degumming of silk filament yarns resulted in more bulky and less open pores for the silk fibroin knit scaffold. The decreased pore size after degumming of knit scaffold alleviated the need to in-advance pore filling (a requisite for increasing cell adhesion in a typical knit scaffold having big pores). From a mechanical viewpoint, the weft knit scaffold shows the highest mechanical strength alongside with far better extensibility. Interestingly, the silk filament weft knit scaffold (in the course direction) was 100 and 1000 times more compliant than silk fibroin film and electrospun web, respectively. The observed effect of material type and fabrication technique highlights the suitability of silk fibroin weft-knit scaffolds for the regeneration of load-bearing soft tissues such as urine bladder.
Collapse
Affiliation(s)
- Sanaz Khademolqorani
- Department of Textile Engineering, Isfahan University of Technology, Isfahan 84156-83111, Iran
| | - Hossein Tavanai
- Department of Textile Engineering, Isfahan University of Technology, Isfahan 84156-83111, Iran; Research Institute for Nanotechnology and Advanced Materials, Isfahan University of Technology, Isfahan 84156-83111, Iran
| | - Ioannis S Chronakis
- Nano-Bioscience Research Group, DTU-Food, Technical University of Denmark, Kemitorvet, B202, 2800 Kgs. Lyngby, Denmark
| | - Anja Boisen
- Department of Health Technology, Technical University of Denmark, Ørsted Plads, 2800 Kgs. Lyngby, Denmark; The Danish National Research Foundation and Villum Foundation's Center for Intelligent Drug Delivery and Sensing Using Microcontainers and Nanomechanics (IDUN), Department of Health Technology, Technical University of Denmark, Ørsted Plads, 2800 Kgs. Lyngby, Denmark
| | - Fatemeh Ajalloueian
- Department of Health Technology, Technical University of Denmark, Ørsted Plads, 2800 Kgs. Lyngby, Denmark; The Danish National Research Foundation and Villum Foundation's Center for Intelligent Drug Delivery and Sensing Using Microcontainers and Nanomechanics (IDUN), Department of Health Technology, Technical University of Denmark, Ørsted Plads, 2800 Kgs. Lyngby, Denmark.
| |
Collapse
|
16
|
Lee H, Jang TS, Han G, Kim HW, Jung HD. Freeform 3D printing of vascularized tissues: Challenges and strategies. J Tissue Eng 2021; 12:20417314211057236. [PMID: 34868539 PMCID: PMC8638074 DOI: 10.1177/20417314211057236] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2021] [Accepted: 10/17/2021] [Indexed: 11/26/2022] Open
Abstract
In recent years, freeform three-dimensional (3D) printing has led to significant advances in the fabrication of artificial tissues with vascularized structures. This technique utilizes a supporting matrix that holds the extruded printing ink and ensures shape maintenance of the printed 3D constructs within the prescribed spatial precision. Since the printing nozzle can be translated omnidirectionally within the supporting matrix, freeform 3D printing is potentially applicable for the fabrication of complex 3D objects, incorporating curved, and irregular shaped vascular networks. To optimize freeform 3D printing quality and performance, the rheological properties of the printing ink and supporting matrix, and the material matching between them are of paramount importance. In this review, we shall compare conventional 3D printing and freeform 3D printing technologies for the fabrication of vascular constructs, and critically discuss their working principles and their advantages and disadvantages. We also provide the detailed material information of emerging printing inks and supporting matrices in recent freeform 3D printing studies. The accompanying challenges are further discussed, aiming to guide freeform 3D printing by the effective design and selection of the most appropriate materials/processes for the development of full-scale functional vascularized artificial tissues.
Collapse
Affiliation(s)
- Hyun Lee
- Department of Biomedical and Chemical
Engineering (BMCE), The Catholic University of Korea, Bucheon, Republic of
Korea
- Department of Biotechnology, The
Catholic University of Korea, Bucheon-si, Gyeonggi-do, Republic of Korea
| | - Tae-Sik Jang
- Department of Materials Science and
Engineering, Chosun University, Gwangju, Republic of Korea
| | - Ginam Han
- Department of Biomedical and Chemical
Engineering (BMCE), The Catholic University of Korea, Bucheon, Republic of
Korea
- Department of Biotechnology, The
Catholic University of Korea, Bucheon-si, Gyeonggi-do, Republic of Korea
| | - Hae-Won Kim
- Institute of Tissue Regeneration
Engineering (ITREN), Dankook University, Cheonan, Chungcheongnam-do, Republic of
Korea
- Department of Biomaterials Science,
College of Dentistry, Dankook University, Cheonan, Chungcheongnam-do, Republic of
Korea
- Department of Nanobiomedical Science
& BK21 PLUS NBM Global Research Center for Regenerative Medicine, Dankook
University, Cheonan, Chungcheongnam-do, Republic of Korea
- Cell & Matter Institute, Dankook
University, Cheonan, Chungcheongnam-do, Republic of Korea
- Department of Regenerative Dental
Medicine, College of Dentistry, Dankook University, Cheonan, Chungcheongnam-do,
Republic of Korea
| | - Hyun-Do Jung
- Department of Biomedical and Chemical
Engineering (BMCE), The Catholic University of Korea, Bucheon, Republic of
Korea
- Department of Biotechnology, The
Catholic University of Korea, Bucheon-si, Gyeonggi-do, Republic of Korea
| |
Collapse
|
17
|
Fusaro L, Gualandi C, Antonioli D, Soccio M, Liguori A, Laus M, Lotti N, Boccafoschi F, Focarete ML. Elastomeric Electrospun Scaffolds of a Biodegradable Aliphatic Copolyester Containing PEG-Like Sequences for Dynamic Culture of Human Endothelial Cells. Biomolecules 2020; 10:E1620. [PMID: 33266333 PMCID: PMC7759847 DOI: 10.3390/biom10121620] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2020] [Revised: 11/26/2020] [Accepted: 11/27/2020] [Indexed: 01/31/2023] Open
Abstract
In the field of artificial prostheses for damaged vessel replacement, polymeric scaffolds showing the right combination of mechanical performance, biocompatibility, and biodegradability are still demanded. In the present work, poly(butylene-co-triethylene trans-1,4-cyclohexanedicarboxylate), a biodegradable random aliphatic copolyester, has been synthesized and electrospun in form of aligned and random fibers properly designed for vascular applications. The obtained materials were analyzed through tensile and dynamic-mechanical tests, the latter performed under conditions simulating the mechanical contraction of vascular tissue. Furthermore, the in vitro biological characterization, in terms of hemocompatibility and cytocompatibility in static and dynamic conditions, was also carried out. The mechanical properties of the investigated scaffolds fit within the range of physiological properties for medium- and small-caliber blood vessels, and the aligned scaffolds displayed a strain-stiffening behavior typical of the blood vessels. Furthermore, all the produced scaffolds showed constant storage and loss moduli in the investigated timeframe (24 h), demonstrating the stability of the scaffolds under the applied conditions of mechanical deformation. The biological characterization highlighted that the mats showed high hemocompatibility and low probability of thrombus formation; finally, the cytocompatibility tests demonstrated that cyclic stretch of electrospun fibers increased endothelial cell activity and proliferation, in particular on aligned scaffolds.
Collapse
Affiliation(s)
| | - Chiara Gualandi
- Department of Chemistry “Giacomo Ciamician” and INSTM UdR of Bologna, University of Bologna, 40126 Bologna, Italy; (C.G.); (A.L.)
- Interdepartmental Center for Industrial Research on Advanced Applications in Mechanical Engineering and Materials Technology, CIRI-MAM, University of Bologna, 40136 Bologna, Italy
| | - Diego Antonioli
- Department of Science and Technological Innovation and INSTM UdR Alessandria, University of Piemonte Orientale, 15121 Alessandria, Italy; (D.A.); (M.L.)
| | - Michelina Soccio
- Department of Civil, Chemical, Environmental and Materials Engineering, University of Bologna, 40131 Bologna, Italy; (M.S.); (N.L.)
| | - Anna Liguori
- Department of Chemistry “Giacomo Ciamician” and INSTM UdR of Bologna, University of Bologna, 40126 Bologna, Italy; (C.G.); (A.L.)
| | - Michele Laus
- Department of Science and Technological Innovation and INSTM UdR Alessandria, University of Piemonte Orientale, 15121 Alessandria, Italy; (D.A.); (M.L.)
| | - Nadia Lotti
- Department of Civil, Chemical, Environmental and Materials Engineering, University of Bologna, 40131 Bologna, Italy; (M.S.); (N.L.)
| | - Francesca Boccafoschi
- Department of Health Sciences, University of Piemonte Orientale, 28100 Novara, Italy
| | - Maria Letizia Focarete
- Department of Chemistry “Giacomo Ciamician” and INSTM UdR of Bologna, University of Bologna, 40126 Bologna, Italy; (C.G.); (A.L.)
- Health Sciences & Technologies (HST) CIRI, University of Bologna, 40064 Ozzano dell’Emilia, Italy
| |
Collapse
|
18
|
Obiweluozor FO, Emechebe GA, Kim DW, Cho HJ, Park CH, Kim CS, Jeong IS. Considerations in the Development of Small-Diameter Vascular Graft as an Alternative for Bypass and Reconstructive Surgeries: A Review. Cardiovasc Eng Technol 2020; 11:495-521. [PMID: 32812139 DOI: 10.1007/s13239-020-00482-y] [Citation(s) in RCA: 36] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/12/2020] [Accepted: 08/11/2020] [Indexed: 02/06/2023]
Abstract
BACKGROUND Current design strategies for small diameter vascular grafts (< 6 mm internal diameter; ID) are focused on mimicking native vascular tissue because the commercially available grafts still fail at small diameters, notably due to development of intimal hyperplasia and thrombosis. To overcome these challenges, various design approaches, material selection, and surface modification strategies have been employed to improve the patency of small-diameter grafts. REVIEW The purpose of this review is to outline various considerations in the development of small-diameter vascular grafts, including material choice, surface modifications to enhance biocompatibility/endothelialization, and mechanical properties of the graft, that are currently being implanted. Additionally, we have taken into account the general vascular physiology, tissue engineering approaches, and collective achievements of the authors in this area. We reviewed both commercially available synthetic grafts (e-PTFE and PET), elastic polymers such as polyurethane and biodegradable and bioresorbable materials. We included naturally occurring materials by focusing on their potential application in the development of future vascular alternatives. CONCLUSION Until now, there are few comprehensive reviews regarding considerations in the design of small-diameter vascular grafts in the literature. Here-in, we have discussed in-depth the various strategies employed to generate engineered vascular graft due to their high demand for vascular surgeries. While some TEVG design strategies have shown greater potential in contrast to autologous or synthetic ePTFE conduits, many are still hindered by high production cost which prevents their widespread adoption. Nonetheless, as tissue engineers continue to develop on their strategies and procedures for improved TEVGs, soon, a reliable engineered graft will be available in the market. Hence, we anticipate a viable TEVG with resorbable property, fabricated via electrospinning approach to hold a greater potential that can overcome the challenges observed in both autologous and allogenic grafts. This is because they can be mechanically tuned, incorporated/surface-functionalized with bioactive molecules and mass-manufactured in a reproducible manner. It is also found that most of the success in engineered vascular graft approaching commercialization is for large vessels rather than small-diameter grafts used as cardiovascular bypass grafts. Consequently, the field of vascular engineering is still available for future innovators that can take up the challenge to create a functional arterial substitute.
Collapse
Affiliation(s)
- Francis O Obiweluozor
- Department of Cardiac and Thoracic Surgery, Chonnam National University Hospital and Medical School, 42 Jebong-Ro Dong-gu, Gwangju, 501-757, Republic of Korea.
| | - Gladys A Emechebe
- Department of Bionanosystem Engineering Graduate School, Chonbuk National University, Jeonju City, Republic of Korea
| | - Do-Wan Kim
- Department of Cardiac and Thoracic Surgery, Chonnam National University Hospital and Medical School, 42 Jebong-Ro Dong-gu, Gwangju, 501-757, Republic of Korea
| | - Hwa-Jin Cho
- Department of Cardiac and Thoracic Surgery, Chonnam National University Hospital and Medical School, 42 Jebong-Ro Dong-gu, Gwangju, 501-757, Republic of Korea
| | - Chan Hee Park
- Department of Bionanosystem Engineering Graduate School, Chonbuk National University, Jeonju City, Republic of Korea
- Department of Mechanical Engineering Graduate School, Chonbuk National University, Jeonju City, Republic of Korea
| | - Cheol Sang Kim
- Department of Bionanosystem Engineering Graduate School, Chonbuk National University, Jeonju City, Republic of Korea
- Department of Mechanical Engineering Graduate School, Chonbuk National University, Jeonju City, Republic of Korea
| | - In Seok Jeong
- Department of Cardiac and Thoracic Surgery, Chonnam National University Hospital and Medical School, 42 Jebong-Ro Dong-gu, Gwangju, 501-757, Republic of Korea.
| |
Collapse
|
19
|
Mallis P, Sokolis DP, Makridakis M, Zoidakis J, Velentzas AD, Katsimpoulas M, Vlahou A, Kostakis A, Stavropoulos-Giokas C, Michalopoulos E. Insights into Biomechanical and Proteomic Characteristics of Small Diameter Vascular Grafts Utilizing the Human Umbilical Artery. Biomedicines 2020; 8:E280. [PMID: 32785189 PMCID: PMC7460081 DOI: 10.3390/biomedicines8080280] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2020] [Revised: 08/08/2020] [Accepted: 08/09/2020] [Indexed: 02/07/2023] Open
Abstract
The gold standard vascular substitutes, used in cardiovascular surgery, are the Dacron or expanded polytetrafluoroethylene (ePTFE)-derived grafts. However, major adverse reactions accompany their use. For this purpose, decellularized human umbilical arteries (hUAs) may be proven as a significant source for the development of small diameter conduits. The aim of this study was the evaluation of a decellularization protocol in hUAs. To study the effect of the decellularization to the hUAs, histological analysis was performed. Then, native and decellularized hUAs were biochemically and biomechanically evaluated. Finally, broad proteomic analysis was applied. Histological analysis revealed the successful decellularization of the hUAs. Furthermore, a great amount of DNA was removed from the decellularized hUAs. Biomechanical analysis revealed statistically significant differences in longitudinal direction only in maximum stress (p < 0.013) and strain (p < 0.001). On the contrary, all parameters tested for circumferential direction exhibited significant differences (p < 0.05). Proteomic analysis showed the preservation of the extracellular matrix and cytoskeletal proteins in both groups. Proteomic data are available via ProteomeXchange with identifier PXD020187. The above results indicated that hUAs were efficiently decellularized. The tissue function properties of these conduits were well retained, making them ideal candidates for the development of small diameter vascular grafts.
Collapse
Affiliation(s)
- Panagiotis Mallis
- Hellenic Cord Blood Bank, Biomedical Research Foundation Academy of Athens, 4 Soranou Ephessiou Street, 115 27 Athens, Greece; (C.S.-G.); (E.M.)
| | - Dimitrios P. Sokolis
- Laboratory of Biomechanics, Center for Experimental Surgery, Biomedical Research Foundation Academy of Athens, 4 Soranou Ephessiou Street, 115 27 Athens, Greece;
| | - Manousos Makridakis
- Biotechnology division, Biomedical Research Foundation Academy of Athens, 4 Soranou Ephessiou Street, 115 27 Athens, Greece; (M.M.); (J.Z.); (A.V.)
| | - Jerome Zoidakis
- Biotechnology division, Biomedical Research Foundation Academy of Athens, 4 Soranou Ephessiou Street, 115 27 Athens, Greece; (M.M.); (J.Z.); (A.V.)
| | - Athanasios D. Velentzas
- Department of Biology, Section of Cell Biology and Biophysics, School of Science, National and Kapodistrian University of Athens, 161 Gr. Kousidi, Zografos, Street, 115 27 Athens, Greece;
| | - Michalis Katsimpoulas
- Center of Experimental Surgery and Translational Research, Biomedical Research Foundation Academy of Athens, 4 Soranou Ephessiou Street, 115 27 Athens, Greece; (M.K.); (A.K.)
| | - Antonia Vlahou
- Biotechnology division, Biomedical Research Foundation Academy of Athens, 4 Soranou Ephessiou Street, 115 27 Athens, Greece; (M.M.); (J.Z.); (A.V.)
| | - Alkiviadis Kostakis
- Center of Experimental Surgery and Translational Research, Biomedical Research Foundation Academy of Athens, 4 Soranou Ephessiou Street, 115 27 Athens, Greece; (M.K.); (A.K.)
| | - Catherine Stavropoulos-Giokas
- Hellenic Cord Blood Bank, Biomedical Research Foundation Academy of Athens, 4 Soranou Ephessiou Street, 115 27 Athens, Greece; (C.S.-G.); (E.M.)
| | - Efstathios Michalopoulos
- Hellenic Cord Blood Bank, Biomedical Research Foundation Academy of Athens, 4 Soranou Ephessiou Street, 115 27 Athens, Greece; (C.S.-G.); (E.M.)
| |
Collapse
|
20
|
Fernández-Colino A, Wolf F, Rütten S, Schmitz-Rode T, Rodríguez-Cabello JC, Jockenhoevel S, Mela P. Small Caliber Compliant Vascular Grafts Based on Elastin-Like Recombinamers for in situ Tissue Engineering. Front Bioeng Biotechnol 2019; 7:340. [PMID: 31803735 PMCID: PMC6877483 DOI: 10.3389/fbioe.2019.00340] [Citation(s) in RCA: 47] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2019] [Accepted: 10/30/2019] [Indexed: 01/04/2023] Open
Abstract
Vascular disease is a leading cause of death worldwide, but surgical options are restricted by the limited availability of autologous vessels, and the suboptimal performance of prosthetic vascular grafts. This is especially evident for coronary artery by-pass grafts, whose small caliber is associated with a high occlusion propensity. Despite the potential of tissue-engineered grafts, compliance mismatch, dilatation, thrombus formation, and the lack of functional elastin are still major limitations leading to graft failure. This calls for advanced materials and fabrication schemes to achieve improved control on the grafts' properties and performance. Here, bioinspired materials and technical textile components are combined to create biohybrid cell-free implants for endogenous tissue regeneration. Clickable elastin-like recombinamers are processed to form an open macroporous 3D architecture to favor cell ingrowth, while being endowed with the non-thrombogenicity and the elastic behavior of the native elastin. The textile components (i.e., warp-knitted and electrospun meshes) are designed to confer suture retention, long-term structural stability, burst strength, and compliance. Notably, by controlling the electrospun layer's thickness, the compliance can be modulated over a wide range of values encompassing those of native vessels. The grafts support cell ingrowth, extracellular matrix deposition and endothelium development in vitro. Overall, the fabrication strategy results in promising off-the-shelf hemocompatible vascular implants for in situ tissue engineering by addressing the known limitations of bioartificial vessel substitutes.
Collapse
Affiliation(s)
- Alicia Fernández-Colino
- Department of Biohybrid & Medical Textiles (BioTex), AME-Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany
| | - Frederic Wolf
- Department of Biohybrid & Medical Textiles (BioTex), AME-Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany
| | - Stephan Rütten
- Electron Microscopy Facility, Uniklinik RWTH Aachen, Aachen, Germany
| | - Thomas Schmitz-Rode
- AME-Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany
| | | | - Stefan Jockenhoevel
- Department of Biohybrid & Medical Textiles (BioTex), AME-Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany.,AMIBM-Aachen-Maastricht-Institute for Biobased Materials, Maastricht University, Geleen, Netherlands
| | - Petra Mela
- Department of Biohybrid & Medical Textiles (BioTex), AME-Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany.,Medical Materials and Implants, Department of Mechanical Engineering and Munich School of BioEngineering, Technical University of Munich, Garching, Germany
| |
Collapse
|
21
|
Mitas P, Grus T, Lambert L, Mlcek M, Chlup H, Honsova E, Dohnalova M, Suchy T, Burgetova A, Lindner J, Spacek M. The influence of purification of carp collagen used in a novel composite graft with sandwich construction of the wall on its biological properties and graft patency rates. Physiol Res 2019; 68:603-610. [PMID: 31177797 DOI: 10.33549/physiolres.934117] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
We compared graft outcome between two types of a novel composite three-layer carp-collagen-coated vascular graft in low-flow conditions in a sheep model. Collagen in group A underwent more cycles of purification than in group B in order to increase the ratio between collagen and residual fat. The grafts were implanted end-to-side in both carotid arteries in sheep (14 grafts in 7 sheep in group A, 18 grafts in 9 sheep in group B) and artificially stenosed on the right side. The flow in the grafts in group A decreased from 297±118 ml/min to 158±159 ml/min (p=0.041) after placement of the artificial stenosis in group A, and from 330±164ml/min to 97±29 ml/min (p=0.0052) in group B (p=0.27 between the groups). From the five surviving animals in group A, both grafts occluded in one animal 3 and 14 days after implantation. In group B, from the six surviving animals, only one graft on the left side remained patent (p=0.0017). Histology showed degradation of the intimal layer in the center with endothelization from the periphery in group A and formation of thick fibrous intimal layer in group B. We conclude that the ratio between collagen and lipid content in the novel three-layer graft plays a critical role in its patency and structural changes in vivo.
Collapse
Affiliation(s)
- P Mitas
- Department of Radiology, First Faculty of Medicine, Charles University and General University Hospital in Prague, Prague, Czech Republic.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
22
|
Chiu YC, Shen YF, Lee AKX, Lin SH, Wu YC, Chen YW. 3D Printing of Amino Resin-based Photosensitive Materials on Multi-parameter Optimization Design for Vascular Engineering Applications. Polymers (Basel) 2019; 11:E1394. [PMID: 31450605 PMCID: PMC6780824 DOI: 10.3390/polym11091394] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2019] [Revised: 08/18/2019] [Accepted: 08/23/2019] [Indexed: 12/19/2022] Open
Abstract
Cardiovascular diseases are currently the most common cause of death globally and of which, the golden treatment method for severe cardiovascular diseases or coronary artery diseases are implantations of synthetic vascular grafts. However, such grafts often come with rejections and hypersensitivity reactions. With the emergence of regenerative medicine, researchers are now trying to explore alternative ways to produce grafts that are less likely to induce immunological reactions in patients. The main goal of such studies is to produce biocompatible artificial vascular grafts with the capability of allowing cellular adhesion and cellular proliferation for tissues regeneration. The Design of Experimental concepts is employed into the manufacturing process of digital light processing (DLP) 3D printing technology to explore near-optimal processing parameters to produce artificial vascular grafts with vascular characteristics that are close to native vessels by assessing for the cause and effect relationships between different ratios of amino resin (AR), 2-hydroxyethyl methacrylate (HEMA), dopamine, and curing durations. We found that with proper optimization of fabrication procedures and ratios of materials, we are able to successfully fabricate vascular grafts with good printing resolutions. These had similar physical properties to native vessels and were able to support cellular adhesion and proliferation. This study could support future studies in exploring near-optimal processes for fabrication of artificial vascular grafts that could be adapted into clinical applications.
Collapse
Affiliation(s)
- Yung-Cheng Chiu
- School of Medicine, China Medical University, Taichung 40447, Taiwan
- Department of Orthopedic Surgery, China Medical University Hospital, Taichung 40447, Taiwan
| | - Yu-Fang Shen
- Department of Bioinformatics and Medical Engineering, Asia University, Taichung 40447, Taiwan
- 3D Printing Medical Research Institute, Asia University, Taichung 40447, Taiwan
| | - Alvin Kai-Xing Lee
- School of Medicine, China Medical University, Taichung 40447, Taiwan
- 3D Printing Medical Research Center, China Medical University Hospital, Taichung 40447, Taiwan
| | - Shu-Hsien Lin
- 3D Printing Medical Research Center, China Medical University Hospital, Taichung 40447, Taiwan
| | - Yu-Chen Wu
- 3D Printing Medical Research Center, China Medical University Hospital, Taichung 40447, Taiwan
| | - Yi-Wen Chen
- 3D Printing Medical Research Center, China Medical University Hospital, Taichung 40447, Taiwan.
- Graduate Institute of Biomedical Sciences, China Medical University, Taichung 40447, Taiwan.
| |
Collapse
|
23
|
Schmitt PJ, Altafulla JJ, Kikuta S, Dupont G, Iwanaga J, Monteith S, Litvack Z, Dumont AS, Tubbs RS. Internal Thoracic Artery to Vertebral Artery Bypass Surgery: A Cadaveric Feasibility Study. World Neurosurg 2019; 130:e722-e725. [PMID: 31284060 DOI: 10.1016/j.wneu.2019.06.203] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2019] [Revised: 06/26/2019] [Accepted: 06/27/2019] [Indexed: 11/29/2022]
Abstract
OBJECTIVE Posterior circulation strokes account for over one quarter of all ischemic strokes. The frequency of vertebral artery origin stenosis (VAOS) in patients with vertebrobasilar insufficiency (VBI) has been estimated to be as high 26%-32%, and VAOS is the direct cause of posterior circulation strokes in 9% of patients. This association could have a significant genetic component. This study examines the feasibility of the internal thoracic artery (ITA) as a donor vessel for revascularization in patients with VAOS. METHODS Ten sides from 5 fresh-frozen white cadaveric necks derived from 3 women and 2 men were used in this study. The mean age of the cadavers at death was 77.2 years (range, 68-88 years). The subclavian artery, vertebral artery, and ITA were dissected. The length and diameter (proximal and distal) of the V1 segment and the length and diameter of the ITA were recorded. Finally, the ITA was transposed to the V1 segment of the vertebral artery (VA1). RESULTS The mean length of the VA1 and its diameter at the proximal and distal parts were 35.51 and 3.69 mm, respectively. The mean length and diameter of the ITA were 26.53 and 3.27 mm, respectively. Rerouting the ITA to the VA1 was feasible without tension on all sides. CONCLUSIONS This study indicates that the ITA is anatomically and hemodynamically an excellent option for bypass surgery in a VAOS scenario. We present convincing and reproducible data to aid neurosurgeons in choosing the procedure best suited to their patients.
Collapse
Affiliation(s)
- Paul J Schmitt
- Swedish Neuroscience Institute, Swedish Medical Center, Seattle, Washington, USA
| | - Juan J Altafulla
- Swedish Neuroscience Institute, Swedish Medical Center, Seattle, Washington, USA; Seattle Science Foundation, Seattle, Washington, USA; Department of Anatomical Sciences, St. George's University, St. George's, Grenada
| | - Shogo Kikuta
- Seattle Science Foundation, Seattle, Washington, USA
| | - Graham Dupont
- Seattle Science Foundation, Seattle, Washington, USA
| | - Joe Iwanaga
- Seattle Science Foundation, Seattle, Washington, USA; Department of Neurosurgery, Tulane University, New Orleans, Louisiana, USA.
| | - Stephen Monteith
- Swedish Neuroscience Institute, Swedish Medical Center, Seattle, Washington, USA
| | - Zachary Litvack
- Swedish Neuroscience Institute, Swedish Medical Center, Seattle, Washington, USA
| | - Aaron S Dumont
- Division of Gross and Clinical Anatomy, Department of Anatomy, Kurume University School of Medicine, Kurume, Japan
| | - R Shane Tubbs
- Seattle Science Foundation, Seattle, Washington, USA; Neurosurgery Department, Hospital Santo Tomas, Panama
| |
Collapse
|
24
|
Development of In Vitro Bioengineered Vascular Grafts for Microsurgery and Vascular Surgery Applications. PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN 2019; 7:e2264. [PMID: 31333980 PMCID: PMC6571351 DOI: 10.1097/gox.0000000000002264] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2019] [Accepted: 03/27/2019] [Indexed: 12/31/2022]
Abstract
Introduction The use of vascular grafts is continuing to rise due to the increasing prevalence of coronary artery bypass grafting and microvascular flap-based tissue reconstructions. The current options of using native vessels (saphenous vein) or the synthetic grafts (Dacron) have been unable to manage current needs. In this study, we employed an original tissue engineering approach to develop a multi-layered vascular graft that has the potential to address some of the limitations of the existing grafts. Materials and Methods Biomaterials, gelatin and fibrin, were used to develop a two-layered vascular graft. The graft was seeded with endothelial cells and imaged using confocal microscopy. The graft's architecture and its mechanical properties were also characterized using histology, Scanning Electron Microscopy and rheological studies. Results Our methodology resulted in the development of a vascular graft with precise spatial localization of the two layers. The endothelial cells fully covered the lumen of the developed vascular graft, thus providing a non-thrombogenic surface. The elastic modulus of the biomaterials employed in this graft was found to be 5.186 KPa, paralleling that of internal mammary artery. The burst pressure of this graft was also measured and was found close to that of the saphenous vein (~2000 mm Hg). Conclusions We were successfully able to employ a unique method to synthesize a multi-layered vascularized graft having adequate biological and mechanical properties. Studies are ongoing involving implantation of this developed vascular graft in the rat femoral artery and characterization of parameters such as vascular remodeling and patency.
Collapse
|
25
|
Abstract
Electrospinning is a versatile and viable technique for generating ultrathin fibers. Remarkable progress has been made with regard to the development of electrospinning methods and engineering of electrospun nanofibers to suit or enable various applications. We aim to provide a comprehensive overview of electrospinning, including the principle, methods, materials, and applications. We begin with a brief introduction to the early history of electrospinning, followed by discussion of its principle and typical apparatus. We then discuss its renaissance over the past two decades as a powerful technology for the production of nanofibers with diversified compositions, structures, and properties. Afterward, we discuss the applications of electrospun nanofibers, including their use as "smart" mats, filtration membranes, catalytic supports, energy harvesting/conversion/storage components, and photonic and electronic devices, as well as biomedical scaffolds. We highlight the most relevant and recent advances related to the applications of electrospun nanofibers by focusing on the most representative examples. We also offer perspectives on the challenges, opportunities, and new directions for future development. At the end, we discuss approaches to the scale-up production of electrospun nanofibers and briefly discuss various types of commercial products based on electrospun nanofibers that have found widespread use in our everyday life.
Collapse
Affiliation(s)
- Jiajia Xue
- The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia 30332, United States
| | - Tong Wu
- The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia 30332, United States
| | - Yunqian Dai
- School of Chemistry and Chemical Engineering, Southeast University, Nanjing, Jiangsu 211189, People’s Republic of China
| | - Younan Xia
- The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia 30332, United States
- School of Chemistry and Biochemistry, School of Chemical and Biomolecular Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332, United States
| |
Collapse
|
26
|
Asakura T, Tanaka T, Tanaka R. Advanced Silk Fibroin Biomaterials and Application to Small-Diameter Silk Vascular Grafts. ACS Biomater Sci Eng 2019; 5:5561-5577. [PMID: 33405687 DOI: 10.1021/acsbiomaterials.8b01482] [Citation(s) in RCA: 41] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
As the incidences of cardiovascular diseases have been on the rise in recent years, the need for small-diameter artificial vascular grafts is increasing globally. Although synthetic polymers such as expanded polytetrafluoroethylene or poly(ethylene terephthalate) have been successfully used for artificial vascular grafts ≥6 mm in diameter, they fail at smaller diameters (<6 mm) due to thrombus formation and intimal hyperplasia. Thus, development of vascular grafts for small diameter vessel replacement that are <6 mm in diameter remains a major clinical challenge. Silk fibroin (SF) from Bombyx mori silkworm is well-known as an excellent textile and also has been used as suture material in surgery for more than 2000 years. Many attempts to develop small-diameter SF vascular grafts with <6 mm in diameter have been reported. Here, research and development in small-diameter vascular grafts with SF are reviewed as follows: (1) the heterogeneous structure of SF fiber (Silk II), including the packing arrangements and type II β-turn structure of SF (Silk I*) before spinning; (2) SF modified by transgenic silkworm, which is more suitable for vascular grafts; (3) preparation of small-diameter SF vascular grafts; (4) characterization of SF in the hydrated state, including dynamics of water molecules by nuclear magnetic resonance; and (5) evaluation of the SF grafts by in vivo implantation experiment. According to the findings, SF is a promising material for small-diameter vascular graft development.
Collapse
Affiliation(s)
- Tetsuo Asakura
- Department of Biotechnology, Tokyo University of Agriculture and Technology, 2-24-16 Nakacho, Koganei, Tokyo 184-8588, Japan
| | - Takashi Tanaka
- Department of Biotechnology, Tokyo University of Agriculture and Technology, 2-24-16 Nakacho, Koganei, Tokyo 184-8588, Japan
| | - Ryo Tanaka
- Department of Biotechnology, Tokyo University of Agriculture and Technology, 2-24-16 Nakacho, Koganei, Tokyo 184-8588, Japan
| |
Collapse
|
27
|
Spacek M, Chlup H, Mitas P, Vesely J, Lambert L, Mlcek M, Krajicek M, Lindner J, Grus T. Three-layer collagen-based vascular graft designed for low-flow peripheral vascular reconstructions. J Appl Biomed 2019; 17:52. [PMID: 34907746 DOI: 10.32725/jab.2019.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2018] [Accepted: 01/16/2019] [Indexed: 11/05/2022] Open
Abstract
INTRODUCTION The aim of this study was to develop a prototype of an artificial blood vessel which has similar mechanical properties to a human saphenous vein graft and to experimentally verify the function of the prosthesis via ovine carotid bypass implantation. MATERIAL AND METHODS The prototype of an artificial graft prosthesis for low flow was developed and manufactured from a collagenous matrix and reinforcing polyester mesh. We compared the results of both the pressurisation and the mechanical stress evaluation tests of VSM with four types of hybrid vascular graft. The most similar graft (type II) was chosen for the first ovine model implantation. RESULTS Dominant behavior e.g. mechanical response of VSM graft in plots of circumferential and axial stress during loading is observed in circumferential direction. Average results of used VSM showed area of ideal mechanical response and the properties of artificial blood vessels were fitted into this area. Developed graft remained patent after 161 days of follow up in ovine model. CONCLUSIONS The mechanical properties of the graft were designed and adjusted to be similar to the behaviour of human saphenous veins. This approach showed promising results and enhanced the final performance of the prosthesis.
Collapse
Affiliation(s)
- Miroslav Spacek
- Charles University and General University Hospital in Prague, First Faculty of Medicine, 2nd Department of Surgery - Department of Cardiovascular Surgery, Prague, Czech Republic
| | - Hynek Chlup
- Czech Technical University in Prague, Faculty of Mechanical Engineering, Department of Mechanics, Biomechanics and Mechatronics, Prague, Czech Republic
| | - Petr Mitas
- Charles University and General University Hospital in Prague, First Faculty of Medicine, 2nd Department of Surgery - Department of Cardiovascular Surgery, Prague, Czech Republic
| | - Jan Vesely
- Czech Technical University in Prague, Faculty of Mechanical Engineering, Department of Mechanics, Biomechanics and Mechatronics, Prague, Czech Republic
| | - Lukas Lambert
- Charles University and General University Hospital in Prague, First Faculty of Medicine, Department of Radiology, Prague, Czech Republic
| | - Mikulas Mlcek
- Charles University, First Faculty of Medicine, Institute of Physiology, Prague, Czech Republic
| | - Milan Krajicek
- Charles University and General University Hospital in Prague, First Faculty of Medicine, 2nd Department of Surgery - Department of Cardiovascular Surgery, Prague, Czech Republic
| | - Jaroslav Lindner
- Charles University and General University Hospital in Prague, First Faculty of Medicine, 2nd Department of Surgery - Department of Cardiovascular Surgery, Prague, Czech Republic
| | - Tomas Grus
- Charles University and General University Hospital in Prague, First Faculty of Medicine, 2nd Department of Surgery - Department of Cardiovascular Surgery, Prague, Czech Republic
| |
Collapse
|
28
|
Lambert L, Novakova M, Lukac P, Cechova D, Sukenikova L, Hrdy J, Mlcek M, Chlup H, Suchy T, Grus T. Evaluation of the Immunogenicity of a Vascular Graft Covered with Collagen Derived from the European Carp ( Cyprinus carpio) and Bovine Collagen. BIOMED RESEARCH INTERNATIONAL 2019; 2019:5301405. [PMID: 30941365 PMCID: PMC6420978 DOI: 10.1155/2019/5301405] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/27/2018] [Accepted: 02/03/2019] [Indexed: 11/17/2022]
Abstract
AIM To assess the systemic and local immunological response to subcutaneous implants of a vascular graft covered with collagen extracted from the European carp (freshwater fish) or with collagen of bovine origin. METHODS Pieces of a vascular graft covered by pure bovine (Bos taurus, BOV, n=14) or carp (Cyprinus carpio, CYP, n=14) collagen 5 mm in size were implanted subcutaneously in the dorsum of a Balb/cOla mice. A sham operation group of 12 animals served as the control. At 7 and 14 days after the operation, one-half of each group was terminated and blood for serum, spleen, and implant with surrounding tissue were collected. Mean cytokine (TNF-α, IL-10, IL-4, IL-1β, IL-13, and IFN-γ) levels in serum were determined using ELISA. Spleen cell cultures were used for in vitro testing of lymphocyte proliferation and cytokine secretion. Local expressions of IL-6, IL-10, TNF-α, TGF-β, CCL-2, and CCL-3 were determined using PCR. RESULTS We found no significant difference among control, BOV, and CYP groups in mean cytokine serum levels at seven days. At day 14, the BOV group had higher levels of TNF-α (P=.018) and both the BOV and CYP groups had lower levels of IL-4 (P=.011 and P=.047, respectively) compared with the control group. Both tested implants showed only a minimal effect on the production of selected cytokines. Cell proliferation in the CYP group stimulated by CYP gel at 14 days was significantly lower than by BOV gel in BOV group (P=.0031) or by CYP gel in the control group (P=.041). The difference between the groups in the local RNA expression of all the tested mediators both at 7 and at 14 days was not significant apart from a lower level of TNF-α in the BOV group compared to CYP at 14 days (P=.013). CONCLUSIONS Implants covered with carp collagen induce an immunological response that is comparable to that of bovine collagen covered implants in a mouse model.
Collapse
Affiliation(s)
- Lukas Lambert
- Department of Radiology, First Faculty of Medicine, Charles University and General University Hospital in Prague, U Nemocnice 2, 128 08 Prague 2, Czech Republic
| | - Michaela Novakova
- Institute of Immunology and Microbiology, First Faculty of Medicine, Charles University and General University Hospital in Prague, Studnickova 7, 128 00 Prague 2, Czech Republic
| | - Peter Lukac
- Department of Cardiovascular Surgery, First Faculty of Medicine, Charles University and General University Hospital in Prague, U Nemocnice 2, 128 08 Prague 2, Czech Republic
| | - Dana Cechova
- Institute of Immunology and Microbiology, First Faculty of Medicine, Charles University and General University Hospital in Prague, Studnickova 7, 128 00 Prague 2, Czech Republic
| | - Lenka Sukenikova
- Institute of Immunology and Microbiology, First Faculty of Medicine, Charles University and General University Hospital in Prague, Studnickova 7, 128 00 Prague 2, Czech Republic
| | - Jiri Hrdy
- Institute of Immunology and Microbiology, First Faculty of Medicine, Charles University and General University Hospital in Prague, Studnickova 7, 128 00 Prague 2, Czech Republic
| | - Mikulas Mlcek
- Institute of Physiology, First Faculty of Medicine, Charles University in Prague, Albertov 5, 128 00, Prague 2, Czech Republic
| | - Hynek Chlup
- Department of Mechanics, Biomechanics and Mechatronics, Faculty of Mechanical Engineering, Czech Technical University in Prague, Technicka 4, 166 07 Prague 6, Czech Republic
| | - Tomas Suchy
- Institute of Rock Structure and Mechanics of the Czech Academy of Sciences, V Holesovickach 41, 182 09, Prague 8, Czech Republic
| | - Tomas Grus
- Department of Cardiovascular Surgery, First Faculty of Medicine, Charles University and General University Hospital in Prague, U Nemocnice 2, 128 08 Prague 2, Czech Republic
| |
Collapse
|
29
|
Weber C, Reinhardt S, Eghbalzadeh K, Wacker M, Guschlbauer M, Maul A, Sterner-Kock A, Wahlers T, Wippermann J, Scherner M. Patency and in vivo compatibility of bacterial nanocellulose grafts as small-diameter vascular substitute. J Vasc Surg 2018; 68:177S-187S.e1. [DOI: 10.1016/j.jvs.2017.09.038] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2017] [Accepted: 09/17/2017] [Indexed: 10/18/2022]
|
30
|
Johnson R, Ding Y, Nagiah N, Monnet E, Tan W. Coaxially-structured fibres with tailored material properties for vascular graft implant. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2018; 97:1-11. [PMID: 30678891 DOI: 10.1016/j.msec.2018.11.036] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/30/2017] [Revised: 10/18/2018] [Accepted: 11/24/2018] [Indexed: 12/21/2022]
Abstract
Readily-available small-diameter arterial grafts require a great combination of materials properties, including high strength, compliance, suturability, blood sealing and anti-thrombogenicity, as well as anti-kinking property for those used in challenging anatomical situations. We have constructed grafts composed of coaxially-structured polycaprolactone (PCL)/gelatin nanofibres, and tailored the material structures to achieve high strength, compliance and kink resistance, as well as excellent water sealing and anti-thrombogenicity. Coaxially-structured fibres in the grafts provided mechanical stability through the core, while flexibility and cell adhesion through the sheath. Results showed that graft compliance increased while strength decreased with the concentration ratio between core and sheath polymers. Compared to pure PCL fibrous surfaces, coaxial PCL/gelatin fibrous surfaces potently inhibited platelet adhesion and activation, providing excellent anti-thrombogenicity. To render sufficient burst strength and suturability, an additional layer of pure PCL was necessary to cap the layer of coaxial PCL/gelatin fibres. The two-layered grafts with the wall thickness comparable to native arteries demonstrated artery-like compliance and kink resistance, properties important to arteries under complex mechanical loading. The in vivo evaluation was performed using the interposition carotid artery graft model in rabbits for three months. Interestingly, results from ultrasonic imaging and histological analysis demonstrated that the two-layered grafts with a thinner outer PCL layer, which possessed higher compliance and kink resistance, showed increased blood flow, minimal lumen reduction and fibrosis. All vascular grafts exhibited patency and induced limited cell infiltration. Together, we presented a facile and useful approach to fabricate vascular grafts with superior graft performances, biomechanical properties, and blood compatibility. Grafts with artery-like compliance and flexibility have demonstrated improved implantation outcomes.
Collapse
Affiliation(s)
- Richard Johnson
- Department of Mechanical Engineering, University of Colorado at Boulder, Boulder, CO 80309, United States
| | - Yonghui Ding
- Department of Mechanical Engineering, University of Colorado at Boulder, Boulder, CO 80309, United States
| | - Naveen Nagiah
- Department of Mechanical Engineering, University of Colorado at Boulder, Boulder, CO 80309, United States
| | - Eric Monnet
- Department of Clinical Sciences, Colorado State University, Fort Colins, CO, United States
| | - Wei Tan
- Department of Mechanical Engineering, University of Colorado at Boulder, Boulder, CO 80309, United States.
| |
Collapse
|
31
|
MODERN METHODS OF TREATING DISEASES OF THE BULBO-MEMBRANOUS PART OF URETHRA. ACTA BIOMEDICA SCIENTIFICA 2018. [DOI: 10.29413/abs.2018-3.5.17] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Strictures of the bulbous-membranous urethra are a common cause of obstructive urination disorder. Modern trends in the development of medicine lead to a wider application of endoscopic method, a more frequent cause of iatrogenic injury of the urethra. At present, conservative, endourologic and reconstructive methods of care are used to treat urethral strictures. There are several conservative, endourological and reconstructive methods for treating patients with urethral stricture. Conservative methods include interventions that do not involve the destruction of urethral stricture or its reconstruction, such as stenting, blind dilatation, and recanalization of the urethra. Performing blind dilatation strictures of the bulbo-membranous urethra is not recommended because of the high risk of false path formation and low efficiency. Endourological operations refer to surgical methods of care and suggest the natural restoration of urethral tissues after the destruction of stricture. Because of the low effectiveness of correction of strictures of the posterior urethra (more than 90 % of relapses in five years), this method is a variant of temporary or palliative care. Currently, two approaches to the reconstruction of the bulbo-membranous urethra are used: anastomotic and replacement operations. Anastomotic surgery involves excision of the affected area and juxtaposition of healthy urethral tissues without tension. Replacement plastic allows to restore patency of the urethra by increasing the diameter of the lumen due to the implantation of various grafts. The article shows that, based on international clinical studies, the most effective method of reconstructing the bulbomembranous urethra is reconstructive surgical methods.
Collapse
|
32
|
Aper T, Wilhelmi M, Boer U, Lau S, Benecke N, Hilfiker A, Haverich A. Dehydration improves biomechanical strength of bioartificial vascular graft material and allows its long-term storage. Innov Surg Sci 2018; 3:215-224. [PMID: 31579785 PMCID: PMC6604580 DOI: 10.1515/iss-2018-0017] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2018] [Accepted: 06/18/2018] [Indexed: 02/01/2023] Open
Abstract
Introduction We have recently reported about a novel technique for the generation of bioartificial vascular grafts based on the use of a compacted fibrin matrix. In this study, we evaluated the effects of a dehydration process on the biomechanical properties of compacted fibrin tubes and whether it allows for their long-term storage. Materials and methods Fibrin was precipitated from fresh frozen plasma by means of cryoprecipitation and simultaneously with a thrombin solution applied in a high-speed rotating casting mold. Subsequent dehydration of the fibrin tubes (29/38) was performed in dry air with a dilator inside the tube to prevent the collapse of the lumen. Dehydrated fibrin tubes were stored for six (n=9) and 12 months (n=10) at room temperature. Comparative analysis was done on initially generated and dehydrated fibrin tubes before and after storage to evaluate the effects of the dehydration process and storage on the biomechanical properties and structure of the tubes. Results Thirty-eight fibrin tubes were generated by high-speed rotation-molding from 142±3 mg fibrinogen with an inner diameter of 5.8±0.1 mm and a length of 100 mm. A centrifugal force of nearly 900×g compacted applied fibrin, while fluid was pressed out of the matrix and drained from the mold via holes resulting in a 16-fold compaction of the fibrin matrix. Dehydration was characterized by shrinkage of the tubes to a diameter of 3.2±0.2 mm, while the length remained at 100 mm equivalent to a further two-fold compaction. The biomechanical strength of the dehydrated fibrin tubes significantly increased to values comparable to that of native ovine carotid arteries and maintained during the first 6 months of storage. After 12 months of storage, only five of 10 tubes were intact, and only one showed maintained biomechanical strength. Discussion Compaction of a fibrin matrix in high-speed rotation-moulding and subsequent dehydration enables for the construction of small-caliber fibrin grafts. Over and above, the dehydration process allows their storage and stockpiling as a prerequisite for clinical use.
Collapse
Affiliation(s)
- Thomas Aper
- Department of Vascular and Endovascular Surgery, Division for Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| | - Mathias Wilhelmi
- Department of Vascular and Endovascular Surgery, Division for Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| | - Ulrike Boer
- Department of Vascular and Endovascular Surgery, Division for Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| | - Skadi Lau
- Department of Vascular and Endovascular Surgery, Division for Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| | - Nils Benecke
- Department of Vascular and Endovascular Surgery, Division for Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| | - Andres Hilfiker
- Department of Vascular and Endovascular Surgery, Division for Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| | - Axel Haverich
- Department of Vascular and Endovascular Surgery, Division for Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| |
Collapse
|
33
|
Moorthi A, Tyan YC, Chung TW. Surface-modified polymers for cardiac tissue engineering. Biomater Sci 2018; 5:1976-1987. [PMID: 28832034 DOI: 10.1039/c7bm00309a] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Cardiovascular disease (CVD), leading to myocardial infarction and heart failure, is one of the major causes of death worldwide. The physiological system cannot significantly regenerate the capabilities of a damaged heart. The current treatment involves pharmacological and surgical interventions; however, less invasive and more cost-effective approaches are sought. Such new approaches are developed to induce tissue regeneration following injury. Hence, regenerative medicine plays a key role in treating CVD. Recently, the extrinsic stimulation of cardiac regeneration has involved the use of potential polymers to stimulate stem cells toward the differentiation of cardiomyocytes as a new therapeutic intervention in cardiac tissue engineering (CTE). The therapeutic potentiality of natural or synthetic polymers and cell surface interactive factors/polymer surface modifications for cardiac repair has been demonstrated in vitro and in vivo. This review will discuss the recent advances in CTE using polymers and cell surface interactive factors that interact strongly with stem cells to trigger the molecular aspects of the differentiation or formulation of cardiomyocytes for the functional repair of heart injuries or cardiac defects.
Collapse
Affiliation(s)
- Ambigapathi Moorthi
- Department of Biomedical Engineering, National Yang Ming University, Taipei 112, Taiwan.
| | | | | |
Collapse
|
34
|
Lee S, Lee S, Kim S, Yoon CH, Park HJ, Kim JY, Choi H. Fabrication and Characterization of a Magnetic Drilling Actuator for Navigation in a Three-dimensional Phantom Vascular Network. Sci Rep 2018; 8:3691. [PMID: 29487359 PMCID: PMC5829245 DOI: 10.1038/s41598-018-22110-5] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2017] [Accepted: 02/16/2018] [Indexed: 01/28/2023] Open
Abstract
Intravascular microrobots have emerged as a promising tool for vascular diseases. They can be wirelessly and precisely manipulated with a high degree of freedom. Previous studies have evaluated their drilling performance and locomotion, and showed the feasibility of using microrobots for biomedical applications in two-dimensional space. However, it is critical to validate micro-drillers in a three-dimensional (3D) environment because gravity plays an important role in a 3D environment and significantly affects the performance of the micro-drillers in vascular networks. In this work, we fabricated magnetic drilling actuators (MDAs) and characterized their locomotion and drilling performance in vascular network-mimicking fluidic channels. The MDAs were precisely manipulated in the fluidic channel network in both horizontal and vertical planes, selecting and moving through the desired path via the junctions of multiple channels. The MDAs also accurately navigated an artificial thrombosis in an artificial 3D vascular network and successfully drilled through it. The results obtained here confirmed the precise manipulation and drilling performance of the developed MDAs in 3D. We think that the MDAs presented in this paper have great potential as intravascular drillers for precise thrombus treatment.
Collapse
Affiliation(s)
- Sunkey Lee
- Department of Robotics Engineering, DGIST, Daegu, 42988, Republic of Korea
- DGIST-ETH Microrobot Research Center, DGIST, Daegu, 42988, Republic of Korea
| | - Seungmin Lee
- Department of Robotics Engineering, DGIST, Daegu, 42988, Republic of Korea
- DGIST-ETH Microrobot Research Center, DGIST, Daegu, 42988, Republic of Korea
| | - Sangwon Kim
- Institute of Robotics and Intelligent Systems, ETH Zurich, Zurich, CH-8092, Switzerland
| | - Chang-Hwan Yoon
- Cardiovascular Center & Department of Internal Medicine, Seoul National University Bundang Hospital, Seongnam, Gyeonggi, 13620, Republic of Korea
| | - Hun-Jun Park
- Cardiology Division, Department of Internal Medicine, College of Medicine, The Catholic University of Korea, Seoul, 06591, Republic of Korea
| | - Jin-Young Kim
- Department of Robotics Engineering, DGIST, Daegu, 42988, Republic of Korea.
- DGIST-ETH Microrobot Research Center, DGIST, Daegu, 42988, Republic of Korea.
| | - Hongsoo Choi
- Department of Robotics Engineering, DGIST, Daegu, 42988, Republic of Korea.
- DGIST-ETH Microrobot Research Center, DGIST, Daegu, 42988, Republic of Korea.
| |
Collapse
|
35
|
Elomaa L, Yang YP. Additive Manufacturing of Vascular Grafts and Vascularized Tissue Constructs. TISSUE ENGINEERING. PART B, REVIEWS 2017; 23:436-450. [PMID: 27981886 PMCID: PMC5652978 DOI: 10.1089/ten.teb.2016.0348] [Citation(s) in RCA: 52] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/25/2016] [Accepted: 11/28/2016] [Indexed: 12/13/2022]
Abstract
There is a great need for engineered vascular grafts among patients with cardiovascular diseases who are in need of bypass therapy and lack autologous healthy blood vessels. In addition, because of the severe worldwide shortage of organ donors, there is an increasing need for engineered vascularized tissue constructs as an alternative to organ transplants. Additive manufacturing (AM) offers great advantages and flexibility of fabrication of cell-laden, multimaterial, and anatomically shaped vascular grafts and vascularized tissue constructs. Various inkjet-, extrusion-, and photocrosslinking-based AM techniques have been applied to the fabrication of both self-standing vascular grafts and porous, vascularized tissue constructs. This review discusses the state-of-the-art research on the use of AM for vascular applications and the key criteria for biomaterials in the AM of both acellular and cellular constructs. We envision that new smart printing materials that can adapt to their environment and encourage rapid endothelialization and remodeling will be the key factor in the future for the successful AM of personalized and dynamic vascular tissue applications.
Collapse
Affiliation(s)
- Laura Elomaa
- Department of Orthopaedic Surgery, Stanford University School of Medicine, Stanford, California
| | - Yunzhi Peter Yang
- Department of Orthopaedic Surgery, Stanford University School of Medicine, Stanford, California
- Department of Materials Science and Engineering, Stanford University School of Engineering, Stanford, California
- Department of Bioengineering, Stanford University School of Engineering, Stanford, California
| |
Collapse
|
36
|
Wu Y, Qin Y, Wang Z, Wang J, Zhang C, Li C, Kong D. The regeneration of macro-porous electrospun poly(ɛ-caprolactone) vascular graft during long-termin situimplantation. J Biomed Mater Res B Appl Biomater 2017; 106:1618-1627. [DOI: 10.1002/jbm.b.33967] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2017] [Revised: 07/23/2017] [Accepted: 07/25/2017] [Indexed: 12/31/2022]
Affiliation(s)
- Yifan Wu
- Tianjin Key Laboratory of Biomaterial Research; Institute of Biomedical Engineering, Chinese Academy of Medical Sciences and Peking Union Medical College; Tianjin 300192 China
- State Key Laboratory of Medicinal Chemical Biology; Key Laboratory of Bioactive Materials, Ministry of Education, College of Life Science, Nankai University; Tianjin 300071 China
| | - Yibo Qin
- Tianjin Key Laboratory of Biomaterial Research; Institute of Biomedical Engineering, Chinese Academy of Medical Sciences and Peking Union Medical College; Tianjin 300192 China
| | - Zhihong Wang
- Tianjin Key Laboratory of Biomaterial Research; Institute of Biomedical Engineering, Chinese Academy of Medical Sciences and Peking Union Medical College; Tianjin 300192 China
| | - Jianing Wang
- State Key Laboratory of Medicinal Chemical Biology; Key Laboratory of Bioactive Materials, Ministry of Education, College of Life Science, Nankai University; Tianjin 300071 China
| | - Chuangnian Zhang
- Tianjin Key Laboratory of Biomaterial Research; Institute of Biomedical Engineering, Chinese Academy of Medical Sciences and Peking Union Medical College; Tianjin 300192 China
| | - Chen Li
- Tianjin Key Laboratory of Biomaterial Research; Institute of Biomedical Engineering, Chinese Academy of Medical Sciences and Peking Union Medical College; Tianjin 300192 China
| | - Deling Kong
- Tianjin Key Laboratory of Biomaterial Research; Institute of Biomedical Engineering, Chinese Academy of Medical Sciences and Peking Union Medical College; Tianjin 300192 China
- State Key Laboratory of Medicinal Chemical Biology; Key Laboratory of Bioactive Materials, Ministry of Education, College of Life Science, Nankai University; Tianjin 300071 China
| |
Collapse
|
37
|
O'Connor RA, McGuinness GB. Electrospun nanofibre bundles and yarns for tissue engineering applications: A review. Proc Inst Mech Eng H 2017; 230:987-998. [PMID: 28095765 DOI: 10.1177/0954411916656664] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Nanofibre membranes produced through the electrospinning process have been studied extensively over the past decade for a number of high demand applications including use as tissue engineered scaffolds. Despite possessing desirable properties including high surface area to volume ratios and enhanced mechanical properties, they ultimately suffer from a lack of cellular infiltration. Variations on the process include the production of highly aligned filaments of electrospun fibres referred to as bundles and yarns. Nanofibre bundle and yarn-based scaffolds have been shown to demonstrate superior cell infiltration rates compared to traditional electrospun nonwovens while also offering the capability to be incorporated into a wider array of post-processing technologies. In this review, fibre collection techniques currently employed within the literature for the fabrication of electrospun bundles and yarns along with their applications in the field of tissue engineering will be discussed.
Collapse
Affiliation(s)
- Richard A O'Connor
- Centre for Medical Engineering Research, School of Mechanical and Manufacturing Engineering, Dublin City University, Dublin, Ireland
| | - Garrett B McGuinness
- Centre for Medical Engineering Research, School of Mechanical and Manufacturing Engineering, Dublin City University, Dublin, Ireland
| |
Collapse
|
38
|
Shojaee M, Bashur CA. Compositions Including Synthetic and Natural Blends for Integration and Structural Integrity: Engineered for Different Vascular Graft Applications. Adv Healthc Mater 2017; 6. [PMID: 28371505 DOI: 10.1002/adhm.201700001] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2017] [Revised: 02/13/2017] [Indexed: 11/07/2022]
Abstract
Tissue engineering approaches for small-diameter arteries require a scaffold that simultaneously maintains patency by preventing thrombosis and intimal hyperplasia, maintains its structural integrity after grafting, and allows integration. While synthetic and extracellular matrix-derived materials can provide some of these properties individually, developing a scaffold that provides the balanced properties needed for vascular graft survival in the clinic has been particularly challenging. After 30 years of research, there are now several scaffolds currently in clinical trials. However, these products are either being investigated for large-diameter applications or they require pre-seeding of endothelial cells. This progress report identifies important challenges unique to engineering vascular grafts for high pressure arteries less than 4 mm in diameter (e.g., coronary artery), and discusses limitations with the current usage of the term "small-diameter." Next, the composition and processing techniques used for generating tissue engineered vascular grafts (TEVGs) are discussed, with a focus on the benefits of blended materials. Other scaffolds for non-tissue engineering approaches and stents are also briefly mentioned for comparison. Overall, this progress report discusses the importance of defining the most critical challenges for small diameter TEVGs, developing new scaffolds to provide these properties, and determining acceptable benchmarks for scaffold responses in the body.
Collapse
|
39
|
Lavery KS, Rhodes C, Mcgraw A, Eppihimer MJ. Anti-thrombotic technologies for medical devices. Adv Drug Deliv Rev 2017; 112:2-11. [PMID: 27496703 DOI: 10.1016/j.addr.2016.07.008] [Citation(s) in RCA: 55] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2016] [Revised: 06/03/2016] [Accepted: 07/26/2016] [Indexed: 01/08/2023]
Abstract
Thrombosis associated with medical devices may lead to dramatic increases in morbidity, mortality and increased health care costs. Innovative strategies are being developed to reduce this complication and provide a safe biocompatible interface between device and blood. This article aims to describe the biological phenomena underlying device-associated thrombosis, and surveys the literature describing current and developing technologies designed to overcome this challenge. To reduce thrombosis, biomaterials with varying topographical properties and incorporating anti-thrombogenic substances on their surface have demonstrated potential. Overall, there is extensive literature describing technical solutions to reduce thrombosis associated with medical devices, but clinical results are required to demonstrate significant long-term benefits.
Collapse
Affiliation(s)
- Karen S Lavery
- Preclinical Sciences, Boston Scientific Corporation, 100 Boston Scientific Way, Marlborough, MA 01752-1234, United States
| | - Candace Rhodes
- Preclinical Sciences, Boston Scientific Corporation, 100 Boston Scientific Way, Marlborough, MA 01752-1234, United States
| | - Adam Mcgraw
- Preclinical Sciences, Boston Scientific Corporation, 100 Boston Scientific Way, Marlborough, MA 01752-1234, United States
| | - Michael J Eppihimer
- Preclinical Sciences, Boston Scientific Corporation, 100 Boston Scientific Way, Marlborough, MA 01752-1234, United States
| |
Collapse
|
40
|
Wang F, Guan X, Wu T, Qiao J, Han Z, Wu J, Yu X, You Q. Acellular Endocardium as a Novel Biomaterial for the Intima of Tissue-Engineered Small-Caliber Vascular Grafts. Artif Organs 2016; 40:E253-E265. [PMID: 27911030 DOI: 10.1111/aor.12814] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2015] [Revised: 05/09/2016] [Accepted: 07/06/2016] [Indexed: 12/14/2022]
Affiliation(s)
- Feng Wang
- Department of Cardiothoracic Surgery; Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine; Shanghai
| | - Xin Guan
- Department of Cardiothoracic Surgery; Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine; Shanghai
| | - TianYi Wu
- Department of Orthopaedics & Traumatology, Faculty of Medicine; Chinese University of Hong Kong, Prince of Wales Hospital; Hong Kong
| | - JianOu Qiao
- Department of Respiratory Medicine; Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine
| | - ZhaoQing Han
- Department of Respiratory Medicine; Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine
| | - JinLong Wu
- Department of Cardiothoracic Surgery; Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine; Shanghai
| | - XiaoWei Yu
- Department of Orthopaedic Surgery; Shanghai Jiao Tong University Affiliated Sixth People's Hospital; Shanghai
| | - QingJun You
- Department of Thoracic and Cardiovascular Surgery; Affiliated Hospital of Jiangnan University; Wuxi China
| |
Collapse
|
41
|
Boire TC, Balikov DA, Lee Y, Guth CM, Cheung-Flynn J, Sung HJ. Biomaterial-Based Approaches to Address Vein Graft and Hemodialysis Access Failures. Macromol Rapid Commun 2016; 37:1860-1880. [PMID: 27673474 PMCID: PMC5156561 DOI: 10.1002/marc.201600412] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2016] [Revised: 08/15/2016] [Indexed: 12/19/2022]
Abstract
Veins used as grafts in heart bypass or as access points in hemodialysis exhibit high failure rates, thereby causing significant morbidity and mortality for patients. Interventional or revisional surgeries required to correct these failures have been met with limited success and exorbitant costs, particularly for the US Centers for Medicare & Medicaid Services. Vein stenosis or occlusion leading to failure is primarily the result of neointimal hyperplasia. Systemic therapies have achieved little long-term success, indicating the need for more localized, sustained, biomaterial-based solutions. Numerous studies have demonstrated the ability of external stents to reduce neointimal hyperplasia. However, successful results from animal models have failed to translate to the clinic thus far, and no external stent is currently approved for use in the US to prevent vein graft or hemodialysis access failures. This review discusses current progress in the field, design considerations, and future perspectives for biomaterial-based external stents. More comparative studies iteratively modulating biomaterial and biomaterial-drug approaches are critical in addressing mechanistic knowledge gaps associated with external stent application to the arteriovenous environment. Addressing these gaps will ultimately lead to more viable solutions that prevent vein graft and hemodialysis access failures.
Collapse
Affiliation(s)
- Timothy C Boire
- Department of Biomedical Engineering, Vanderbilt University, 37235, Nashville, TN, USA
| | - Daniel A Balikov
- Department of Biomedical Engineering, Vanderbilt University, 37235, Nashville, TN, USA
| | - Yunki Lee
- Department of Biomedical Engineering, Vanderbilt University, 37235, Nashville, TN, USA
| | - Christy M Guth
- Division of Vascular Surgery, Department of Surgery, Vanderbilt University Medical Center, Nashville, TN, 37235, USA
| | - Joyce Cheung-Flynn
- Division of Vascular Surgery, Department of Surgery, Vanderbilt University Medical Center, Nashville, TN, 37235, USA
| | - Hak-Joon Sung
- Department of Biomedical Engineering, Vanderbilt University, 37235, Nashville, TN, USA
- Severance Biomedical Science Institute, College of Medicine, Yonsei University, Seoul, 120-752, Republic of Korea
| |
Collapse
|
42
|
Hiob MA, She S, Muiznieks LD, Weiss AS. Biomaterials and Modifications in the Development of Small-Diameter Vascular Grafts. ACS Biomater Sci Eng 2016; 3:712-723. [DOI: 10.1021/acsbiomaterials.6b00220] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Matti A. Hiob
- School of Life and Environmental Sciences, University of Sydney, Sydney, NSW 2006, Australia
- Charles Perkins Centre, University of Sydney, Sydney, NSW 2006, Australia
| | - Shelley She
- School of Life and Environmental Sciences, University of Sydney, Sydney, NSW 2006, Australia
- Charles Perkins Centre, University of Sydney, Sydney, NSW 2006, Australia
| | - Lisa D. Muiznieks
- Molecular Structure and Function Program, Research Institute, Hospital for Sick Children, 555 University Avenue, Toronto, ON M5G1X8, Canada
| | - Anthony S. Weiss
- School of Life and Environmental Sciences, University of Sydney, Sydney, NSW 2006, Australia
- Charles Perkins Centre, University of Sydney, Sydney, NSW 2006, Australia
- Bosch Institute, University of Sydney, Sydney, NSW 2006, Australia
| |
Collapse
|
43
|
Hsia K, Yao CL, Chen WM, Chen JH, Lee H, Lu JH. Scaffolds and Cell-Based Tissue Engineering for Blood Vessel Therapy. Cells Tissues Organs 2016; 202:281-295. [PMID: 27548610 DOI: 10.1159/000448169] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/04/2016] [Indexed: 11/19/2022] Open
Abstract
The increasing morbidity of cardiovascular diseases in modern society has made it crucial to develop a small-caliber blood vessel. In the absence of appropriate autologous vascular grafts, an alternative prosthesis must be constructed for cardiovascular disease patients. The aim of this article is to describe the advances in making cell-seeded cardiovascular prostheses. It also discusses the combinations of types of scaffolds and cells, especially autologous stem cells, which are suitable for application in tissue-engineered vessels with the favorable properties of mechanical strength, antithrombogenicity, biocompliance, anti-inflammation, fatigue resistance and long-term durability. This article highlights the advancements in cellular tissue-engineered vessels in recent years.
Collapse
|
44
|
Cutiongco MFA, Kukumberg M, Peneyra JL, Yeo MS, Yao JY, Rufaihah AJ, Le Visage C, Ho JP, Yim EKF. Submillimeter Diameter Poly(Vinyl Alcohol) Vascular Graft Patency in Rabbit Model. Front Bioeng Biotechnol 2016; 4:44. [PMID: 27376059 PMCID: PMC4896917 DOI: 10.3389/fbioe.2016.00044] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2016] [Accepted: 05/17/2016] [Indexed: 11/13/2022] Open
Abstract
Microvascular surgery is becoming a prevalent surgical practice. Replantation, hand reconstruction, orthopedic, and free tissue transfer procedures all rely on microvascular surgery for the repair of venous and arterial defects at the millimeter and submillimeter levels. Often, a vascular graft is required for the procedure as a means to bridge the gap between native arteries. While autologous vessels are desired for their bioactivity and non-thrombogenicity, the tedious harvest process, lack of availability, and caliber or mechanical mismatch contribute to graft failure. Thus, there is a need for an off-the-shelf artificial vascular graft that has low thrombogenic properties and mechanical properties matching those of submillimeter vessels. Poly(vinyl alcohol) hydrogel (PVA) has excellent prospects as a vascular graft due to its bioinertness, low thrombogenicity, high water content, and tunable mechanical properties. Here, we fabricated PVA grafts with submillimeter diameter and mechanical properties that closely approximated those of the rabbit femoral artery. In vitro platelet adhesion and microparticle release assay verified the low thrombogenicity of PVA. A stringent proof-of-concept in vivo test was performed by implanting PVA grafts in rabbit femoral artery with multilevel arterial occlusion. Laser Doppler measurements indicated the improved perfusion of the distal limb after implantation with PVA grafts. Moreover, ultrasound Doppler and angiography verified that the submillimeter diameter PVA vascular grafts remained patent for 2 weeks without the aid of anticoagulant or antithrombotics. Endothelial cells were observed in the luminal surface of one patent PVA graft. The advantageous non-thrombogenic and tunable mechanical properties of PVA that are retained even in the submillimeter diameter dimensions support the application of this biomaterial for vascular replacement in microvascular surgery.
Collapse
Affiliation(s)
- Marie F A Cutiongco
- Mechanobiology Institute, National University of Singapore, Singapore; Department of Biomedical Engineering, National University of Singapore, Singapore
| | - Marek Kukumberg
- Mechanobiology Institute, National University of Singapore , Singapore
| | | | - Matthew S Yeo
- Division of Plastic, Reconstructive and Aesthetic Surgery, Department of Surgery, National University Health System, Singapore; Plastic, Reconstructive and Aesthetic Surgery Section, Department of General Surgery, Tan Tock Seng Hospital, Singapore
| | - Jia Y Yao
- Department of Biomedical Engineering, National University of Singapore , Singapore
| | - Abdul Jalil Rufaihah
- Department of Surgery, Yong Loo Lin School of Medicine, National University of Singapore , Singapore
| | - Catherine Le Visage
- INSERM, U791, Center for OsteoArticular and Dental Tissue Engineering, Université de Nantes , Nantes , France
| | - Jackie Pei Ho
- Department of Surgery, Yong Loo Lin School of Medicine, National University of Singapore, Singapore; Department of Cardiovascular and Thoracic Surgery, National University Health System, Singapore
| | - Evelyn K F Yim
- Mechanobiology Institute, National University of Singapore, Singapore; Department of Biomedical Engineering, National University of Singapore, Singapore; Department of Surgery, Yong Loo Lin School of Medicine, National University of Singapore, Singapore; Department of Chemical Engineering, University of Waterloo, Waterloo, ON, Canada
| |
Collapse
|
45
|
Aper T, Wilhelmi M, Gebhardt C, Hoeffler K, Benecke N, Hilfiker A, Haverich A. Novel method for the generation of tissue-engineered vascular grafts based on a highly compacted fibrin matrix. Acta Biomater 2016; 29:21-32. [PMID: 26472610 DOI: 10.1016/j.actbio.2015.10.012] [Citation(s) in RCA: 49] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2015] [Revised: 10/04/2015] [Accepted: 10/09/2015] [Indexed: 12/11/2022]
Abstract
The generation of tissue-engineered blood vessel substitutes remains an ongoing challenge for cardiovascular tissue engineering. Full biocompatibility and immediate availability have emerged as central issues for clinical use. To address these issues, we developed a technique that allows the generation of highly stable tubular fibrin segments. The process is based on the compaction of fibrin in a custom-made high-speed rotation mold. In an automated process, fibrin is precipitated from plasma by means of the Vivostat® system. Following application to the rotating mold, the fibrin was compacted by centrifugal force and excess fluid was pressed out. This compaction results in increasing cross-links between the fibrin fibrils and a corresponding significant increase of biomechanical stability up to a burst strength of 230mm of mercury. The molding process allows for a simultaneous seeding procedure. In a first in vivo evaluation in a sheep model, segments of the carotid artery were replaced by tissue-engineered vascular grafts, generated immediately prior to implantation (n=6). Following subjection to the body's remodeling mechanisms, the segments showed a high structural similarity to a native artery after explantation at 6months. Thus, this technique may represent a powerful tool for the generation of biomechanically stable vascular grafts immediately prior to implantation. STATEMENT OF SIGNIFICANCE Fibrin has previously been shown to be suitable as a matrix for the seeding of different celltypes and for that reason was widely used as scaffold in different fields of tissue engineering. Nevertheless, fibrin's lack of stability has strongly limited its application. Our study describes a novel moulding technique for the generation of a highly compacted fibrin matrix. Using this approach, it was possible to optimize the engineering process of tubular fibrin segments to provide bioartificial vascular grafts within one hour with sufficient stability for immediate implantation in the arterial system. Thus, this technique may represent a powerful tool to get closer to the ultimate aim of an optimal bioartificial vascular graft.
Collapse
Affiliation(s)
- Thomas Aper
- Department of Vascular and Endovascular Surgery, Division for Cardiothoracic-, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany.
| | - Mathias Wilhelmi
- Department of Vascular and Endovascular Surgery, Division for Cardiothoracic-, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| | - Christin Gebhardt
- Department of Vascular and Endovascular Surgery, Division for Cardiothoracic-, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| | - Klaus Hoeffler
- Department of Vascular and Endovascular Surgery, Division for Cardiothoracic-, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| | - Nils Benecke
- Department of Vascular and Endovascular Surgery, Division for Cardiothoracic-, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| | - Andres Hilfiker
- Department of Vascular and Endovascular Surgery, Division for Cardiothoracic-, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| | - Axel Haverich
- Department of Vascular and Endovascular Surgery, Division for Cardiothoracic-, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| |
Collapse
|
46
|
Aper T. Maßgeschneiderte autologe bioartifizielle Gefäßprothesen. ZEITSCHRIFT FUR HERZ THORAX UND GEFASSCHIRURGIE 2015. [DOI: 10.1007/s00398-015-0026-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
47
|
Sankaran KK, Subramanian A, Krishnan UM, Sethuraman S. Nanoarchitecture of scaffolds and endothelial cells in engineering small diameter vascular grafts. Biotechnol J 2015; 10:96-108. [DOI: 10.1002/biot.201400415] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2014] [Revised: 10/27/2014] [Accepted: 12/03/2014] [Indexed: 12/14/2022]
|
48
|
Yuan S, Xiong G, He F, Jiang W, Liang B, Choong C. Multifunctional REDV-conjugated zwitterionic polycarboxybetaine–polycaprolactone hybrid surfaces for enhanced antibacterial activity, anti-thrombogenicity and endothelial cell proliferation. J Mater Chem B 2015; 3:8088-8101. [DOI: 10.1039/c5tb01598g] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Multifunctional PCL hybrid surfaces are developed by grafting of REDV–zwitterionic polycarboxybetaine conjugates via surface-initiated ATRP.
Collapse
Affiliation(s)
- Shaojun Yuan
- Multiphase Mass Transfer & Reaction Engineering Lab
- College of Chemical Engineering
- Sichuan University
- Chengdu
- 610065 China
| | - Gordon Xiong
- Division of Materials Technology
- School of Materials Science and Engineering
- Nanyang Technological University
- Singapore
| | - Fei He
- Multiphase Mass Transfer & Reaction Engineering Lab
- College of Chemical Engineering
- Sichuan University
- Chengdu
- 610065 China
| | - Wei Jiang
- Multiphase Mass Transfer & Reaction Engineering Lab
- College of Chemical Engineering
- Sichuan University
- Chengdu
- 610065 China
| | - Bin Liang
- Multiphase Mass Transfer & Reaction Engineering Lab
- College of Chemical Engineering
- Sichuan University
- Chengdu
- 610065 China
| | - Cleo Choong
- Division of Materials Technology
- School of Materials Science and Engineering
- Nanyang Technological University
- Singapore
| |
Collapse
|
49
|
Wang ZY, Teoh SH, Johana NB, Khoon Chong MS, Teo EY, Hong MH, Yen Chan JK, San Thian E. Enhancing mesenchymal stem cell response using uniaxially stretched poly(ε-caprolactone) film micropatterns for vascular tissue engineering application. J Mater Chem B 2014; 2:5898-5909. [PMID: 32262034 DOI: 10.1039/c4tb00522h] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Abstract
Regeneration of tunica media with anisotropic architecture still remains a challenging issue for vascular tissue engineering (TE). Herein, we present the development of flexible poly(ε-caprolactone) (PCL) film micropatterns to regulate mesenchymal stem cells (MSCs) function for tunica media construction. Results showed that uniaxial thermal stretching of PCL films resulted in topographical micropatterns comprising of ridges/grooves, and improved mechanical properties, including yield stress, Young's modulus, and fracture stress without sacrificing film elasticity. Culturing on such PCL film micropatterns, MSCs self-aligned along the ridges with a more elongated morphology as compared to that of the un-stretched film group. Moreover, MSCs obtained a contractile SMCs-like phenotype, with ordered organization of cellular stress filaments and upregulated expression of the contractile makers, including SM-α-actin, calponin, and SM-MHC. The PCL film micropatterns could be rolled into a small-diameter 3D tubular scaffold with circumferential anisotropy of ridges/grooves, and in the incorporation of MSCs, which facilitated a hybrid sandwich-like vascular wall construction with ordered cell architecture similar to that of the tunica media. These results provide insights of how geometric cues are able to regulate stem cells with desired functions and have significant implications for the designing of a functionalized vascular TE scaffold with appropriate topographical geometries for guiding tunica media regeneration with microscale control of cell alignment and genetic expression.
Collapse
Affiliation(s)
- Zu-Yong Wang
- Department of Mechanical Engineering, National University of Singapore, 9 Engineering Drive 1, Singapore 117 576, Singapore.
| | | | | | | | | | | | | | | |
Collapse
|
50
|
Scherner M, Reutter S, Klemm D, Sterner-Kock A, Guschlbauer M, Richter T, Langebartels G, Madershahian N, Wahlers T, Wippermann J. In vivo application of tissue-engineered blood vessels of bacterial cellulose as small arterial substitutes: proof of concept? J Surg Res 2014; 189:340-7. [DOI: 10.1016/j.jss.2014.02.011] [Citation(s) in RCA: 95] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2013] [Revised: 02/07/2014] [Accepted: 02/11/2014] [Indexed: 12/27/2022]
|