1
|
Kong L, Jin W, Jiang Y, Yan F, Liu J, Leuthardt EC, Yang GZ, Feng Y. Transcranial vibration stimulation at 40 Hz induced neural activity and promoted the coupling of global brain activity and cerebrospinal fluid flow. Neuroimage 2025; 308:121074. [PMID: 39920982 DOI: 10.1016/j.neuroimage.2025.121074] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2024] [Revised: 01/23/2025] [Accepted: 02/03/2025] [Indexed: 02/10/2025] Open
Abstract
BACKGROUND Neuroscience advances have highlighted the potential of non-invasive brain stimulation in influencing cognitive and emotional processes. Conventional stimulation methods such as electrical, magnetic, and ultrasound have been studied intensively, but little is known about the mechanical stimulation. OBJECTIVE To investigate the effects of 40 Hz transcranial vibration stimulation (TVS) on human brain activity, specifically focusing on changes in the Amplitude of Low-Frequency Fluctuation (ALFF), fractional ALFF (fALFF) and Regional Homogeneity (ReHo) as measures of spontaneous brain activity. Additionally, this study investigates alterations in the global blood-oxygen-level-dependent (gBOLD) signal and cerebrospinal fluid (CSF) inflow coupling, which serve as indicators of glymphatic system function. METHODS A custom-built head actuator was used to apply 40 Hz TVS to human brain. Functional magnetic resonance imaging (fMRI) were performed before and after 5 mins TVS to explore the changes in ALFF and fALFF and the coupling of global brain activity with cerebrospinal fluid flow (CSF), which is related to the glymphatic clearance. RESULTS Significant increases were observed in both ALFF and fALFF metrics, indicating that 40 Hz TVS effectively enhanced spontaneous brain activity. Additionally, 40 Hz TVS promoted the synchronization of overall brain activity with CSF, suggesting an improvement in glymphatic clearance processes, an effect that 30 Hz or 50 Hz TVS did not replicate. CONCLUSION Non-invasive brain stimulation using TVS provided important implications for modulating brain physiology and showed prospective therapeutic benefits for neurological diseases.
Collapse
Affiliation(s)
- Linghan Kong
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200230, China; Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai 200240, China; National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy (NERC-AMRT), Shanghai Jiao Tong University, Shanghai 200240, China
| | - Wei Jin
- Department of Neurology and Institute of Neurology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China
| | - Yue Jiang
- Department of Neurosurgery, The First Affiliated Hospital of Xinxiang Medical University, Weihui, Henan 453100, China
| | - Fuhua Yan
- Department of Radiology, Ruijin Hospital, Shanghai 200025, China
| | - Jun Liu
- Department of Neurology and Institute of Neurology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China
| | - Eric C Leuthardt
- Department of Neurosurgery, Washington University School of Medicine in St. Louis, Washington MO 63110, USA
| | - Guang-Zhong Yang
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200230, China; Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai 200240, China; National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy (NERC-AMRT), Shanghai Jiao Tong University, Shanghai 200240, China.
| | - Yuan Feng
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200230, China; Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai 200240, China; National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy (NERC-AMRT), Shanghai Jiao Tong University, Shanghai 200240, China; Department of Radiology, Ruijin Hospital, Shanghai 200025, China.
| |
Collapse
|
2
|
Derosiere G, Shokur S, Vassiliadis P. Reward signals in the motor cortex: from biology to neurotechnology. Nat Commun 2025; 16:1307. [PMID: 39900901 PMCID: PMC11791067 DOI: 10.1038/s41467-024-55016-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2024] [Accepted: 11/25/2024] [Indexed: 02/05/2025] Open
Abstract
Over the past decade, research has shown that the primary motor cortex (M1), the brain's main output for movement, also responds to rewards. These reward signals may shape motor output in its final stages, influencing movement invigoration and motor learning. In this Perspective, we highlight the functional roles of M1 reward signals and propose how they could guide advances in neurotechnologies for movement restoration, specifically brain-computer interfaces and non-invasive brain stimulation. Understanding M1 reward signals may open new avenues for enhancing motor control and rehabilitation.
Collapse
Affiliation(s)
- Gerard Derosiere
- Lyon Neuroscience Research Center, Impact team, INSERM U1028 - CNRS UMR5292, Lyon 1 University, Bron, France.
| | - Solaiman Shokur
- Translational Neural Engineering Laboratory, Neuro-X Institute, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
- Sensorimotor Neurotechnology Lab (SNL), The BioRobotics Institute, Health Interdisciplinary Center and Department of Excellence in Robotics and AI, Scuola Superiore Sant'Anna, Pisa, Italy
- MySpace Lab, Department of Clinical Neurosciences, University Hospital of Lausanne, University of Lausanne, Lausanne, Switzerland
- MINE Lab, Università Vita-Salute San Raffaele, Milano, Italy
| | - Pierre Vassiliadis
- Defitech Chair of Clinical Neuroengineering, Neuro-X Institute (INX), École Polytechnique Fédérale de Lausanne (EPFL), Geneva, Switzerland.
- Defitech Chair of Clinical Neuroengineering, INX, EPFL Valais, Clinique Romande de Réadaptation, Sion, Switzerland.
| |
Collapse
|
3
|
Li Z, Wang H, Zhang X, Lu C, Yu S, Yu B, Li Y, Zeng K, Li X. Cross-species characterization of transcranial ultrasound propagation. Brain Stimul 2025; 18:164-172. [PMID: 39809411 DOI: 10.1016/j.brs.2025.01.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2024] [Revised: 01/10/2025] [Accepted: 01/10/2025] [Indexed: 01/16/2025] Open
Abstract
BACKGROUND Transcranial ultrasound stimulation (TUS) has shown promising prospects as a non-invasive neuromodulation technique for both animals and humans. However, ultrasonic propagation characteristics within the brain differ significantly from those in free space. There is currently a lack of comprehensive studies on the effects of skull thickness on focal point position, full width at half maximum (FWHM), and acoustic intensity. OBJECTIVE This study investigates the transcranial acoustic field characteristics of 500 kHz focused ultrasound, with a focus on the impact of skull thickness. METHODS The study combined finite element simulations to evaluate the effects of skull thickness on 500 kHz focused ultrasound with experimental investigations across multiple species (mouse, rat, pig, and human). RESULTS The simulation and experimental results indicate that the skull changes focal length (-4.4-4.7 mm) and axial focal region (-7.93-7.59 mm), and the skull causes significant attenuation of acoustic intensity, which increases with skull thickness. The attenuation rate of human skulls is greater than 80 %. We found that the skull thickness has little effect on focal point position (<0.9 mm) and focal region (<1.44 mm) in lateral and vertical directions. CONCLUSION Skull thickness has great influence on focal length, axial focal region and acoustic intensity, but has little effect on focal point position and focal region in lateral and vertical directions. And improving axial spatial resolution is a potential method to reduce changes of axial focal region.
Collapse
Affiliation(s)
- Zhiwei Li
- The School of Electrical Engineering, Yanshan University, Qinhuangdao, 066004, China
| | - Hanwen Wang
- The School of Information Science and Engineering, Yanshan University, Qinhuangdao, 066004, China
| | - Xiaoyu Zhang
- The School of Information Science and Engineering, Yanshan University, Qinhuangdao, 066004, China
| | - Chengbiao Lu
- Henan International Key Laboratory for Noninvasive Neuromodulation, Xinxiang Medical University, Xinxiang, 453003, China
| | - Shouyang Yu
- Key Laboratory of Anesthesia and Organ Protection of Ministry of Education (In Cultivation), Zunyi Medical University, Zunyi, 563000, China
| | - Bin Yu
- Henan International Key Laboratory for Noninvasive Neuromodulation, Xinxiang Medical University, Xinxiang, 453003, China
| | - Yingwei Li
- The School of Information Science and Engineering, Yanshan University, Qinhuangdao, 066004, China.
| | - Ke Zeng
- Department of Psychology, Faculty of Arts and Sciences, Center for Cognition and Neuroergonomics, State Key Laboratory of Cognitive Neuroscience and Learning, Beijing Normal University, Zhuhai, 519087, China; Beijing Key Laboratory of Applied Experimental Psychology, National Demonstration Center for Experimental Psychology Education (Beijing Normal University), Faculty of Psychology, Beijing Normal University, Beijing, 100875, China.
| | - Xiaoli Li
- Pazhou Lab (Guangzhou), Guangzhou, 510335, China; The School of Automation Science and Engineering, South China University of Technology, Guangzhou, 510641, China.
| |
Collapse
|
4
|
Keihani A, Sanguineti C, Chaichian O, Huston CA, Moore C, Cheng C, Janssen SA, Donati FL, Mayeli A, Moussawi K, Phillips ML, Ferrarelli F. Transcranial Focused Ultrasound Neuromodulation in Psychiatry: Main Characteristics, Current Evidence, and Future Directions. Brain Sci 2024; 14:1095. [PMID: 39595858 PMCID: PMC11592166 DOI: 10.3390/brainsci14111095] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2024] [Revised: 10/26/2024] [Accepted: 10/28/2024] [Indexed: 11/28/2024] Open
Abstract
Non-invasive brain stimulation (NIBS) techniques are designed to precisely and selectively target specific brain regions, thus enabling focused modulation of neural activity. Among NIBS technologies, low-intensity transcranial focused ultrasound (tFUS) has emerged as a promising new modality. The application of tFUS can safely and non-invasively stimulate deep brain structures with millimetric precision, offering distinct advantages in terms of accessibility to non-cortical regions over other NIBS methods. However, to date, several tFUS aspects still need to be characterized; furthermore, there are only a handful of studies that have utilized tFUS in psychiatric populations. This narrative review provides an up-to-date overview of key aspects of this NIBS technique, including the main components of a tFUS system, the neuronavigational tools used to precisely target deep brain regions, the simulations utilized to optimize the stimulation parameters and delivery of tFUS, and the experimental protocols employed to evaluate the efficacy of tFUS in psychiatric disorders. The main findings from studies in psychiatric populations are presented and discussed, and future directions are highlighted.
Collapse
Affiliation(s)
- Ahmadreza Keihani
- Department of Psychiatry, University of Pittsburgh, Pittsburgh, PA 15213, USA; (A.K.); (C.S.); (O.C.); (C.A.H.); (C.M.); (C.C.); (S.A.J.); (A.M.); (M.L.P.)
| | - Claudio Sanguineti
- Department of Psychiatry, University of Pittsburgh, Pittsburgh, PA 15213, USA; (A.K.); (C.S.); (O.C.); (C.A.H.); (C.M.); (C.C.); (S.A.J.); (A.M.); (M.L.P.)
- Department of Health Sciences, University of Milan, 20142 Milan, Italy
| | - Omeed Chaichian
- Department of Psychiatry, University of Pittsburgh, Pittsburgh, PA 15213, USA; (A.K.); (C.S.); (O.C.); (C.A.H.); (C.M.); (C.C.); (S.A.J.); (A.M.); (M.L.P.)
| | - Chloe A. Huston
- Department of Psychiatry, University of Pittsburgh, Pittsburgh, PA 15213, USA; (A.K.); (C.S.); (O.C.); (C.A.H.); (C.M.); (C.C.); (S.A.J.); (A.M.); (M.L.P.)
| | - Caitlin Moore
- Department of Psychiatry, University of Pittsburgh, Pittsburgh, PA 15213, USA; (A.K.); (C.S.); (O.C.); (C.A.H.); (C.M.); (C.C.); (S.A.J.); (A.M.); (M.L.P.)
| | - Cynthia Cheng
- Department of Psychiatry, University of Pittsburgh, Pittsburgh, PA 15213, USA; (A.K.); (C.S.); (O.C.); (C.A.H.); (C.M.); (C.C.); (S.A.J.); (A.M.); (M.L.P.)
| | - Sabine A. Janssen
- Department of Psychiatry, University of Pittsburgh, Pittsburgh, PA 15213, USA; (A.K.); (C.S.); (O.C.); (C.A.H.); (C.M.); (C.C.); (S.A.J.); (A.M.); (M.L.P.)
| | - Francesco L. Donati
- Department of Psychiatry, University of Pittsburgh, Pittsburgh, PA 15213, USA; (A.K.); (C.S.); (O.C.); (C.A.H.); (C.M.); (C.C.); (S.A.J.); (A.M.); (M.L.P.)
| | - Ahmad Mayeli
- Department of Psychiatry, University of Pittsburgh, Pittsburgh, PA 15213, USA; (A.K.); (C.S.); (O.C.); (C.A.H.); (C.M.); (C.C.); (S.A.J.); (A.M.); (M.L.P.)
| | - Khaled Moussawi
- Department of Neurology, University of California, San Francisco, CA 94143, USA;
| | - Mary L. Phillips
- Department of Psychiatry, University of Pittsburgh, Pittsburgh, PA 15213, USA; (A.K.); (C.S.); (O.C.); (C.A.H.); (C.M.); (C.C.); (S.A.J.); (A.M.); (M.L.P.)
| | - Fabio Ferrarelli
- Department of Psychiatry, University of Pittsburgh, Pittsburgh, PA 15213, USA; (A.K.); (C.S.); (O.C.); (C.A.H.); (C.M.); (C.C.); (S.A.J.); (A.M.); (M.L.P.)
| |
Collapse
|
5
|
Naftchi-Ardebili K, Menz MD, Salahshoor H, Popelka GR, Baccus SA, Butts Pauly K. Focal Volume, Acoustic Radiation Force, and Strain in Two-Transducer Regimes. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2024; 71:1199-1216. [PMID: 39240744 PMCID: PMC11584166 DOI: 10.1109/tuffc.2024.3456048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/08/2024]
Abstract
Transcranial ultrasound stimulation (TUS) holds promise for noninvasive neural modulation in treating neurological disorders. Most clinically relevant targets are deep within the brain (near or at its geometric center), surrounded by other sensitive regions that need to be spared clinical intervention. However, in TUS, increasing frequency with the goal of improving spatial resolution reduces the effective penetration depth. We show that by using a pair of 1-MHz orthogonally arranged transducers, we improve the spatial resolution afforded by each of the transducers individually, by nearly 40 folds, achieving a subcubic millimeter target volume of [Formula: see text]. We show that orthogonally placed transducers generate highly localized standing waves with acoustic radiation force (ARF) arranged into periodic regions of compression and tension near the target. We further present an extended capability of the orthogonal setup, which is to impart selective pressures-either positive or negative, but not both-on the target. Finally, we share our preliminary findings that strain can arise from both particle motion (PM) and ARF with the former reaching its maximum value at the focus and the latter remaining null at the focus and reaching its maximum around the focus. As the field is investigating the mechanism of interaction in TUS by way of elucidating the mapping between ultrasound parameters and neural response, orthogonal transducers expand our toolbox by making it possible to conduct these investigations at much finer spatial resolutions, with localized and directed (compression versus tension) ARF and the capability of applying selective pressures at the target.
Collapse
|
6
|
Kim S, Kwon N, Hossain MM, Bendig J, Konofagou EE. Displacement and functional ultrasound (fUS) imaging of displacement-guided focused ultrasound (FUS) neuromodulation in mice. Neuroimage 2024; 298:120768. [PMID: 39096984 DOI: 10.1016/j.neuroimage.2024.120768] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2024] [Revised: 07/26/2024] [Accepted: 07/31/2024] [Indexed: 08/05/2024] Open
Abstract
Focused ultrasound (FUS) stimulation is a promising neuromodulation technique with the merits of non-invasiveness, high spatial resolution, and deep penetration depth. However, simultaneous imaging of FUS-induced brain tissue displacement and the subsequent effect of FUS stimulation on brain hemodynamics has proven challenging thus far. In addition, earlier studies lack in situ confirmation of targeting except for the magnetic resonance imaging-guided FUS system-based studies. The purpose of this study is 1) to introduce a fully ultrasonic approach to in situ target, modulate neuronal activity, and monitor the resultant neuromodulation effect by respectively leveraging displacement imaging, FUS, and functional ultrasound (fUS) imaging, and 2) to investigate FUS-evoked cerebral blood volume (CBV) response and the relationship between CBV and displacement. We performed displacement imaging on craniotomized mice to confirm the in situ targeting for neuromodulation site. We recorded hemodynamic responses evoked by FUS while fUS imaging revealed an ipsilateral CBV increase that peaks at 4 s post-FUS. We report a stronger hemodynamic activation in the subcortical region than cortical, showing good agreement with a brain elasticity map that can also be obtained using a similar methodology. We observed dose-dependent CBV responses with peak CBV, activated area, and correlation coefficient increasing with the ultrasonic dose. Furthermore, by mapping displacement and hemodynamic activation, we found that displacement colocalized and linearly correlated with CBV increase. The findings presented herein demonstrated that FUS evokes ipsilateral hemodynamic activation in cortical and subcortical depths while the evoked hemodynamic responses colocalize and correlate with FUS-induced displacement. We anticipate that our findings will help consolidate accurate targeting as well as shedding light on one of the mechanisms behind FUS modulation, i.e., how FUS mechanically displaces brain tissue affecting cerebral hemodynamics and thereby its associated connectivity.
Collapse
Affiliation(s)
- Seongyeon Kim
- Department of Biomedical Engineering, Columbia University
| | - Nancy Kwon
- Department of Biomedical Engineering, Columbia University
| | | | - Jonas Bendig
- Department of Biomedical Engineering, Columbia University
| | - Elisa E Konofagou
- Department of Biomedical Engineering, Columbia University; Department of Radiology, Columbia University.
| |
Collapse
|
7
|
Patel D, Shetty S, Acha C, Pantoja IEM, Zhao A, George D, Gracias DH. Microinstrumentation for Brain Organoids. Adv Healthc Mater 2024; 13:e2302456. [PMID: 38217546 DOI: 10.1002/adhm.202302456] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2023] [Revised: 12/10/2023] [Indexed: 01/15/2024]
Abstract
Brain organoids are three-dimensional aggregates of self-organized differentiated stem cells that mimic the structure and function of human brain regions. Organoids bridge the gaps between conventional drug screening models such as planar mammalian cell culture, animal studies, and clinical trials. They can revolutionize the fields of developmental biology, neuroscience, toxicology, and computer engineering. Conventional microinstrumentation for conventional cellular engineering, such as planar microfluidic chips; microelectrode arrays (MEAs); and optical, magnetic, and acoustic techniques, has limitations when applied to three-dimensional (3D) organoids, primarily due to their limits with inherently two-dimensional geometry and interfacing. Hence, there is an urgent need to develop new instrumentation compatible with live cell culture techniques and with scalable 3D formats relevant to organoids. This review discusses conventional planar approaches and emerging 3D microinstrumentation necessary for advanced organoid-machine interfaces. Specifically, this article surveys recently developed microinstrumentation, including 3D printed and curved microfluidics, 3D and fast-scan optical techniques, buckling and self-folding MEAs, 3D interfaces for electrochemical measurements, and 3D spatially controllable magnetic and acoustic technologies relevant to two-way information transfer with brain organoids. This article highlights key challenges that must be addressed for robust organoid culture and reliable 3D spatiotemporal information transfer.
Collapse
Affiliation(s)
- Devan Patel
- Department of Chemical and Biomolecular Engineering, Johns Hopkins University, Baltimore, MD, 21218, USA
| | - Saniya Shetty
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, 21218, USA
| | - Chris Acha
- Department of Chemical and Biomolecular Engineering, Johns Hopkins University, Baltimore, MD, 21218, USA
| | - Itzy E Morales Pantoja
- Center for Alternatives to Animal Testing (CAAT), Department of Environmental Health and Engineering, Bloomberg School of Public Health, Johns Hopkins University, Baltimore, MD, 21205, USA
| | - Alice Zhao
- Department of Biology, Johns Hopkins University, Baltimore, MD, 21218, USA
| | - Derosh George
- Department of Chemical and Biomolecular Engineering, Johns Hopkins University, Baltimore, MD, 21218, USA
| | - David H Gracias
- Department of Chemical and Biomolecular Engineering, Johns Hopkins University, Baltimore, MD, 21218, USA
- Department of Chemistry, Johns Hopkins University, Baltimore, MD, 21218, USA
- Department of Materials Science and Engineering, Johns Hopkins University, Baltimore, MD, 21218, USA
- Department of Oncology, Johns Hopkins University School of Medicine, Baltimore, MD, 21205, USA
- Laboratory for Computational Sensing and Robotics (LCSR), Johns Hopkins University, Baltimore, MD, 21218, USA
- Sidney Kimmel Comprehensive Cancer Center (SKCCC), Johns Hopkins School of Medicine, Baltimore, MD, 21205, USA
- Center for MicroPhysiological Systems (MPS), Johns Hopkins School of Medicine, Baltimore, MD, 21205, USA
| |
Collapse
|
8
|
Pellow C, Pichardo S, Pike GB. A systematic review of preclinical and clinical transcranial ultrasound neuromodulation and opportunities for functional connectomics. Brain Stimul 2024; 17:734-751. [PMID: 38880207 DOI: 10.1016/j.brs.2024.06.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2024] [Revised: 05/21/2024] [Accepted: 06/05/2024] [Indexed: 06/18/2024] Open
Abstract
BACKGROUND Low-intensity transcranial ultrasound has surged forward as a non-invasive and disruptive tool for neuromodulation with applications in basic neuroscience research and the treatment of neurological and psychiatric conditions. OBJECTIVE To provide a comprehensive overview and update of preclinical and clinical transcranial low intensity ultrasound for neuromodulation and emphasize the emerging role of functional brain mapping to guide, better understand, and predict responses. METHODS A systematic review was conducted by searching the Web of Science and Scopus databases for studies on transcranial ultrasound neuromodulation, both in humans and animals. RESULTS 187 relevant studies were identified and reviewed, including 116 preclinical and 71 clinical reports with subjects belonging to diverse cohorts. Milestones of ultrasound neuromodulation are described within an overview of the broader landscape. General neural readouts and outcome measures are discussed, potential confounds are noted, and the emerging use of functional magnetic resonance imaging is highlighted. CONCLUSION Ultrasound neuromodulation has emerged as a powerful tool to study and treat a range of conditions and its combination with various neural readouts has significantly advanced this platform. In particular, the use of functional magnetic resonance imaging has yielded exciting inferences into ultrasound neuromodulation and has the potential to advance our understanding of brain function, neuromodulatory mechanisms, and ultimately clinical outcomes. It is anticipated that these preclinical and clinical trials are the first of many; that transcranial low intensity focused ultrasound, particularly in combination with functional magnetic resonance imaging, has the potential to enhance treatment for a spectrum of neurological conditions.
Collapse
Affiliation(s)
- Carly Pellow
- Department of Radiology, Cumming School of Medicine, University of Calgary, Alberta, T2N 1N4, Canada; Hotchkiss Brain Institute, University of Calgary, Alberta, T2N 4N1, Canada.
| | - Samuel Pichardo
- Department of Radiology, Cumming School of Medicine, University of Calgary, Alberta, T2N 1N4, Canada; Hotchkiss Brain Institute, University of Calgary, Alberta, T2N 4N1, Canada; Department of Clinical Neurosciences, Cumming School of Medicine, University of Calgary, Alberta, T2N 1N4, Canada
| | - G Bruce Pike
- Department of Radiology, Cumming School of Medicine, University of Calgary, Alberta, T2N 1N4, Canada; Hotchkiss Brain Institute, University of Calgary, Alberta, T2N 4N1, Canada; Department of Clinical Neurosciences, Cumming School of Medicine, University of Calgary, Alberta, T2N 1N4, Canada
| |
Collapse
|
9
|
Debbi L, Machour M, Dahis D, Shoyhet H, Shuhmaher M, Potter R, Tabory Y, Goldfracht I, Dennis I, Blechman T, Fuchs T, Azhari H, Levenberg S. Ultrasound Mediated Polymerization for Cell Delivery, Drug Delivery, and 3D Printing. SMALL METHODS 2024; 8:e2301197. [PMID: 38376006 DOI: 10.1002/smtd.202301197] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Indexed: 02/21/2024]
Abstract
Safe and accurate in situ delivery of biocompatible materials is a fundamental requirement for many biomedical applications. These include sustained and local drug release, implantation of acellular biocompatible scaffolds, and transplantation of cells and engineered tissues for functional restoration of damaged tissues and organs. The common practice today includes highly invasive operations with major risks of surgical complications including adjacent tissue damage, infections, and long healing periods. In this work, a novel non-invasive delivery method is presented for scaffold, cells, and drug delivery deep into the body to target inner tissues. This technology is based on acousto-sensitive materials which are polymerized by ultrasound induction through an external transducer in a rapid and local fashion without additional photoinitiators or precursors. The applicability of this technology is demonstrated for viable and functional cell delivery, for drug delivery with sustained release profiles, and for 3D printing. Moreover, the mechanical properties of the delivered scaffold can be tuned to the desired target tissue as well as controlling the drug release profile. This promising technology may shift the paradigm for local and non-invasive material delivery approach in many clinical applications as well as a new printing method - "acousto-printing" for 3D printing and in situ bioprinting.
Collapse
Affiliation(s)
- Lior Debbi
- Faculty of Biomedical Engineering, Technion-Israel Institute of Technology, Haifa, 3200003, Israel
| | - Majd Machour
- Faculty of Biomedical Engineering, Technion-Israel Institute of Technology, Haifa, 3200003, Israel
| | - Daniel Dahis
- Faculty of Biomedical Engineering, Technion-Israel Institute of Technology, Haifa, 3200003, Israel
| | - Hagit Shoyhet
- Faculty of Biomedical Engineering, Technion-Israel Institute of Technology, Haifa, 3200003, Israel
| | - Margarita Shuhmaher
- Faculty of Biomedical Engineering, Technion-Israel Institute of Technology, Haifa, 3200003, Israel
| | - Ruth Potter
- Faculty of Biomedical Engineering, Technion-Israel Institute of Technology, Haifa, 3200003, Israel
| | - Yael Tabory
- Faculty of Biomedical Engineering, Technion-Israel Institute of Technology, Haifa, 3200003, Israel
| | - Idit Goldfracht
- Faculty of Biomedical Engineering, Technion-Israel Institute of Technology, Haifa, 3200003, Israel
| | - Itiel Dennis
- Faculty of Biomedical Engineering, Technion-Israel Institute of Technology, Haifa, 3200003, Israel
| | - Tom Blechman
- Faculty of Biomedical Engineering, Technion-Israel Institute of Technology, Haifa, 3200003, Israel
| | - Theodor Fuchs
- Faculty of Biomedical Engineering, Technion-Israel Institute of Technology, Haifa, 3200003, Israel
| | - Haim Azhari
- Faculty of Biomedical Engineering, Technion-Israel Institute of Technology, Haifa, 3200003, Israel
| | - Shulamit Levenberg
- Faculty of Biomedical Engineering, Technion-Israel Institute of Technology, Haifa, 3200003, Israel
| |
Collapse
|
10
|
Tan R, Ma R, Chu F, Zhou X, Wang X, Yin T, Liu Z. Study on Improving the Modulatory Effect of Rhythmic Oscillations by Transcranial Magneto-Acoustic Stimulation. IEEE Trans Neural Syst Rehabil Eng 2024; 32:1796-1805. [PMID: 38691431 DOI: 10.1109/tnsre.2024.3395641] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/03/2024]
Abstract
In hippocampus, synaptic plasticity and rhythmic oscillations reflect the cytological basis and the intermediate level of cognition, respectively. Transcranial ultrasound stimulation (TUS) has demonstrated the ability to elicit changes in neural response. However, the modulatory effect of TUS on synaptic plasticity and rhythmic oscillations was insufficient in the present studies, which may be attributed to the fact that TUS acts mainly through mechanical forces. To enhance the modulatory effect on synaptic plasticity and rhythmic oscillations, transcranial magneto-acoustic stimulation (TMAS) which induced a coupled electric field together with TUS's ultrasound field was applied. The modulatory effect of TMAS and TUS with a pulse repetition frequency of 100 Hz were compared. TMAS/TUS were performed on C57 mice for 7 days at two different ultrasound intensities (3 W/cm2 and 5 W/cm [Formula: see text]. Behavioral tests, long-term potential (LTP) and local field potentials in vivo were performed to evaluate TUS/TMAS modulatory effect on cognition, synaptic plasticity and rhythmic oscillations. Protein expression based on western blotting were used to investigate the under- lying mechanisms of these beneficial effects. At 5 W/cm2, TMAS-induced LTP were 113.4% compared to the sham group and 110.5% compared to TUS. Moreover, the relative power of high gamma oscillations (50-100Hz) in the TMAS group ( 1.060±0.155 %) was markedly higher than that in the TUS group ( 0.560±0.114 %) and sham group ( 0.570±0.088 %). TMAS significantly enhanced the synchronization of theta and gamma oscillations as well as theta-gamma cross-frequency coupling. Whereas, TUS did not show relative enhancements. TMAS provides enhanced effect for modulating the synaptic plasticity and rhythmic oscillations in hippocampus.
Collapse
|
11
|
Meng W, Lin Z, Lu Y, Long X, Meng L, Su C, Wang Z, Niu L. Spatiotemporal Distributions of Acoustic Propagation in Skull During Ultrasound Neuromodulation. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2024; 71:584-595. [PMID: 38557630 DOI: 10.1109/tuffc.2024.3383027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/04/2024]
Abstract
There is widespread interest and concern about the evidence and hypothesis that the auditory system is involved in ultrasound neuromodulation. We have addressed this problem by performing acoustic shear wave simulations in mouse skull and behavioral experiments in deaf mice. The simulation results showed that shear waves propagating along the skull did not reach sufficient acoustic pressure in the auditory cortex to modulate neurons. Behavioral experiments were subsequently performed to awaken anesthetized mice with ultrasound targeting the motor cortex or ventral tegmental area (VTA). The experimental results showed that ultrasound stimulation (US) of the target areas significantly increased arousal scores even in deaf mice, whereas the loss of ultrasound gel abolished the effect. Immunofluorescence staining also showed that ultrasound can modulate neurons in the target area, whereas neurons in the auditory cortex required the involvement of the normal auditory system for activation. In summary, the shear waves propagating along the skull cannot reach the auditory cortex and induce neuronal activation. Ultrasound neuromodulation-induced arousal behavior needs direct action on functionally relevant stimulation targets in the absence of auditory system participation.
Collapse
|
12
|
Kim YH, Kang KC, Kim JN, Park KK, Firouzi K, Khuri-Yakub BT. High-spatial-resolution transcranial focused ultrasound neuromodulation using frequency-modulated pattern interference radiation force. ULTRASONICS 2024; 140:107298. [PMID: 38531115 DOI: 10.1016/j.ultras.2024.107298] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/13/2022] [Revised: 07/28/2023] [Accepted: 03/13/2024] [Indexed: 03/28/2024]
Abstract
Stimulating the brain in a precise location is crucial in ultrasound neuromodulation. However, improving the resolution proves a challenge owing to the characteristics of transcranial focused ultrasound. In this paper, we present a new neuromodulation system that overcomes the existing limitations based on an acoustic radiation force with a frequency-modulated waveform and standing waves. By using the frequency-modulated pattern interference radiation force (FM-PIRF), the axial spatial resolution can be reduced to a single wavelength level and the target location can be controlled in axial direction electronically. A linear frequency-modulated chirp waveform used in the experiment was designed based on the simulation results. The displacement of the polydimethylsiloxane (PDMS) cantilever was measured at intervals of 0.1 mm to visualize the distribution of radiation force. These results and methods experimentally show that FM-PIRF has improved spatial resolution and capability of electrical movement.
Collapse
Affiliation(s)
- Young Hun Kim
- Mechanical Convergence Engineering, Hanyang University, Seoul 04763, Republic of Korea; Edward. L. Ginzton Lab, Stanford University, Stanford, CA 94305, USA
| | - Ki Chang Kang
- Mechanical Convergence Engineering, Hanyang University, Seoul 04763, Republic of Korea
| | - Jeong Nyeon Kim
- Edward. L. Ginzton Lab, Stanford University, Stanford, CA 94305, USA
| | - Kwan Kyu Park
- Edward. L. Ginzton Lab, Stanford University, Stanford, CA 94305, USA.
| | - Kamyar Firouzi
- Edward. L. Ginzton Lab, Stanford University, Stanford, CA 94305, USA
| | - Butrus T Khuri-Yakub
- Department of Electrical Engineering, Stanford University, Stanford, CA 94305, USA.
| |
Collapse
|
13
|
Kim S, Kwon N, Hossain MM, Bendig J, Konofagou EE. Functional ultrasound (fUS) imaging of displacement-guided focused ultrasound (FUS) neuromodulation in mice. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2024:2024.03.29.587355. [PMID: 38617295 PMCID: PMC11014490 DOI: 10.1101/2024.03.29.587355] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/16/2024]
Abstract
Focused ultrasound (FUS) stimulation is a promising neuromodulation technique with the merits of non-invasiveness, high spatial resolution, and deep penetration depth. However, simultaneous imaging of FUS-induced brain tissue displacement and the subsequent effect of FUS stimulation on brain hemodynamics has proven challenging thus far. In addition, earlier studies lack in situ confirmation of targeting except for the magnetic resonance imaging-guided FUS system-based studies. The purpose of this study is 1) to introduce a fully ultrasonic approach to in situ target, modulate neuronal activity, and monitor the resultant neuromodulation effect by respectively leveraging displacement imaging, FUS, and functional ultrasound (fUS) imaging, and 2) to investigate FUS-evoked cerebral blood volume (CBV) response and the relationship between CBV and displacement. We performed displacement imaging on craniotomized mice to confirm the in targeting for neuromodulation site. We recorded hemodynamic responses evoked by FUS and fUS revealed an ipsilateral CBV increase that peaks at 4 s post-FUS. We saw a stronger hemodynamic activation in the subcortical region than cortical, showing good agreement with the brain elasticity map that can also be obtained using a similar methodology. We observed dose-dependent CBV response with peak CBV, activated area, and correlation coefficient increasing with ultrasonic dose. Furthermore, by mapping displacement and hemodynamic activation, we found that displacement colocalizes and linearly correlates with CBV increase. The findings presented herein demonstrated that FUS evokes ipsilateral hemodynamic activation in cortical and subcortical depths and the evoked hemodynamic responses colocalized and correlate with FUS-induced displacement. We anticipate that our findings will help consolidate accurate targeting as well as an understanding of how FUS displaces brain tissue and affects cerebral hemodynamics.
Collapse
Affiliation(s)
- Seongyeon Kim
- Department of Biomedical Engineering, Columbia University
| | - Nancy Kwon
- Department of Biomedical Engineering, Columbia University
| | | | - Jonas Bendig
- Department of Biomedical Engineering, Columbia University
| | - Elisa E. Konofagou
- Department of Biomedical Engineering, Columbia University
- Department of Radiology, Columbia University
| |
Collapse
|
14
|
Lin CW, Cheng MH, Fan CH, Chen HH, Yeh CK. Focused ultrasound stimulation of infralimbic cortex attenuates reinstatement of methamphetamine-induced conditioned place preference in rats. Neurotherapeutics 2024; 21:e00328. [PMID: 38355360 PMCID: PMC10937235 DOI: 10.1016/j.neurot.2024.e00328] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2023] [Revised: 01/25/2024] [Accepted: 01/26/2024] [Indexed: 02/16/2024] Open
Abstract
Methamphetamine (MA) use disorder poses significant challenges to both the affected individuals and society. Current non-drug therapies like transcranial direct-current stimulation and transcranial magnetic stimulation have limitations due to their invasive nature and limited reach to deeper brain areas. Transcranial focused ultrasound (FUS) is gaining attention as a noninvasive option with precise spatial targeting, able to affect deeper areas of the brain. This research focused on assessing the effectiveness of FUS in influencing the infralimbic cortex (IL) to prevent the recurrence of MA-seeking behavior, using the conditioned place preference (CPP) method in rats. The study involved twenty male Sprague-Dawley rats. Neuronal activation by FUS was first examined via electromyography (EMG). Rats received alternately with MA or saline, and confined to one of two distinctive compartments in a three compartment apparatus over a 4-day period. After CPP test, extinction, the first reinstatement, and extinction again, FUS was applied to IL prior to the second MA priming-induced reinstatement. Safety assessments were conducted through locomotor and histological function examinations. EMG data confirmed the effectiveness of FUS in activating neurons. Significant attenuation of reinstatement of MA CPP was found, along with successful targeting of the IL region, confirmed through acoustic field scanning, c-Fos immunohistochemistry, and Evans blue dye staining. No damage to brain tissue or impaired locomotor activity was observed. The results of the study indicate that applying FUS to the IL markedly reduced the recurrence of MA seeking behavior, without harming brain tissue or impairing motor skills. This suggests that FUS could be a promising method for treating MA use disorder, with the infralimbic cortex being an effective target for FUS in preventing MA relapse.
Collapse
Affiliation(s)
- Chia-Wei Lin
- Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu, Taiwan
| | - Min-Hsuan Cheng
- Center for Neuropsychiatric Research, National Health Research Institutes, Miaoli, Taiwan
| | - Ching-Hsiang Fan
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan; Medical Device Innovation Center, National Cheng Kung University, Tainan, Taiwan
| | - Hwei-Hsien Chen
- Center for Neuropsychiatric Research, National Health Research Institutes, Miaoli, Taiwan; Institute of Neuroscience, National Chengchi University, Taipei, Taiwan; Graduate Program for Aging, China Medical University, Taichung, Taiwan.
| | - Chih-Kuang Yeh
- Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu, Taiwan.
| |
Collapse
|
15
|
Lee J, Kim YE, Lim J, Jo Y, Lee HJ, Jo YS, Choi JS. Transcranial focused ultrasound stimulation in the infralimbic cortex facilitates extinction of conditioned fear in rats. Brain Stimul 2024; 17:405-412. [PMID: 38537689 DOI: 10.1016/j.brs.2024.03.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2023] [Revised: 03/04/2024] [Accepted: 03/15/2024] [Indexed: 05/01/2024] Open
Abstract
Transcranial focused ultrasound (tFUS) neuromodulation emerges as a promising non-invasive approach for improving neurological conditions. Extinction of conditioned fear has served as a prime model for exposure-based therapies for anxiety disorders. We investigated whether tFUS stimulation to a critical brain area, the infralimbic subdivision of the prefrontal cortex (IL), could facilitate fear extinction using rats. In a series of experiments, tFUS was delivered to the IL of a freely-moving rat and compared to sham stimulation (tFUS vs. SHAM). Initially, Fos expression in the IL was measured shortly after the stimulation. The results show that Fos expression was significantly increased in the IL but not in the neighboring regions compared to SHAM. Subsequently, two groups of rats were subjected to fear conditioning, extinction, and retention while receiving stimulation during the extinction. Rats in the tFUS group froze significantly less than SHAM during both extinction and retention tests. Importantly, the reduced freezing in the tFUS group was not attributable to non-specific effect such as auditory noise, as both groups demonstrated a similar level of locomotive activity in an open field regardless of the stimulation condition. Finally, we replicated the procedure with a shortened conditioning-to-extinction interval (15 min) to induce immediate extinction deficit. The tFUS group showed a facilitated reduction in freezing during the extinction, which persisted in the subsequent retention session compared to SHAM. In summary, the current findings suggest that tFUS stimulation in the IL facilitates fear extinction, offering a potential therapeutic regimen for fear-related psychiatric disorders.
Collapse
Affiliation(s)
- Jaeyong Lee
- School of Psychology, Korea University, Seoul, 02841, Republic of Korea
| | - Ye Eun Kim
- School of Psychology, Korea University, Seoul, 02841, Republic of Korea
| | - Jihong Lim
- School of Electrical Engineering, KAIST, Daejeon, 34141, Republic of Korea
| | - Yehhyun Jo
- School of Electrical Engineering, KAIST, Daejeon, 34141, Republic of Korea
| | - Hyunjoo Jenny Lee
- School of Electrical Engineering, KAIST, Daejeon, 34141, Republic of Korea
| | - Yong Sang Jo
- School of Psychology, Korea University, Seoul, 02841, Republic of Korea
| | - June-Seek Choi
- School of Psychology, Korea University, Seoul, 02841, Republic of Korea.
| |
Collapse
|
16
|
Riley MR, Roeder BM, Zinke W, Weisend MP, Eidum DM, Pinton GF, Biliroglu AO, Yamaner FY, Oralkan O, Hampson RE, Connolly PM. Activation of primate frontal eye fields with a CMUT phased array system. J Neurosci Methods 2024; 402:110009. [PMID: 37952832 DOI: 10.1016/j.jneumeth.2023.110009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Revised: 10/16/2023] [Accepted: 11/09/2023] [Indexed: 11/14/2023]
Abstract
BACKGROUND There are pushes toward non-invasive stimulation of neural tissues to prevent issues that arise from invasive brain recordings and stimulation. Transcranial Focused Ultrasound (TFUS) has been examined as a way to stimulate non-invasively, but previous studies have limitations in the application of TFUS. As a result, refinement is needed to improve stimulation results. NEW METHOD We utilized a custom-built capacitive micromachined ultrasonic transducer (CMUT) that would send ultrasonic waves through skin and skull to targets located in the Frontal Eye Fields (FEF) region triangulated from co-registered MRI and CT scans while a non-human primate subject was performing a discrimination behavioral task. RESULTS We observed that the stimulation immediately caused changes in the local field potential (LFP) signal that continued until stimulation ended, at which point there was higher voltage upon the cue for the animal to saccade. This co-incided with increases in activity in the alpha band during stimulation. The activity rebounded mid-way through our electrode-shank, indicating a specific point of stimulation along the shank. We observed different LFP signals for different stimulation targets, indicating the ability to"steer" the stimulation through the transducer. We also observed a bias in first saccades towards the opposite direction. CONCLUSIONS In conclusion, we provide a new approach for non-invasive stimulation during performance of a behavioral task. With the ability to steer stimulation patterns and target using a large amount of transducers, the ability to provide non-invasive stimulation will be greatly improved for future clinical and research applications.
Collapse
Affiliation(s)
| | - Brent M Roeder
- Wake Forest University School of Medicine, United States
| | | | | | | | - Gianmarco F Pinton
- University of North Carolina at Chapel Hill, North Carolina State University, United States
| | | | | | | | | | | |
Collapse
|
17
|
Shi Y, Weng W, Chen M, Huang H, Chen X, Peng Y, Hu Y. Improving DNA vaccination performance through a new microbubble design and an optimized sonoporation protocol. ULTRASONICS SONOCHEMISTRY 2023; 101:106685. [PMID: 37976565 PMCID: PMC10692915 DOI: 10.1016/j.ultsonch.2023.106685] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/20/2023] [Revised: 10/23/2023] [Accepted: 11/05/2023] [Indexed: 11/19/2023]
Abstract
As a non-viral transfection method, ultrasound and microbubble-induced sonoporation can achieve spatially targeted gene delivery with synergistic immunostimulatory effects. Here, we report for the first time the application of sonoporation for improving DNA vaccination performance. This study developed a new microbubble design with nanoscale DNA/PEI complexes loaded onto cationic microbubbles to attain significant increases in DNA-loading capacity (0.25 pg per microbubble) and in vitro transfection efficiency. Using live-cell imaging, we revealed the membrane perforation and cellular delivery characteristics of sonoporation. Using luciferase reporter gene for in vivo transfection, we showed that sonoporation increased the transfection efficiency by 40.9-fold when compared with intramuscular injection. Moreover, we comprehensively optimized the sonoporation protocol and further increased the transfection efficiency by 43.6-fold. Immunofluorescent staining results showed that sonoporation effectively activated the MHC-II+ immune cells. Using a hepatitis B DNA vaccine, sonoporation induced significantly higher serum antibody levels when compared with intramuscular injection, and the antibodies sustained for 56 weeks. In addition, we recorded the longest reported expression period (400 days) of the sonoporation-delivered gene. Whole genome resequencing confirmed that the gene with stable expression existed in an extrachromosomal state without integration. Our results demonstrated the potential of sonoporation for efficient and safe DNA vaccination.
Collapse
Affiliation(s)
- Yuanchao Shi
- School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen 518055, Guangdong, China; National-regional Key Technology Engineering Laboratory for Medical Ultrasound, Shenzhen University, Shenzhen 518055, Guangdong, China
| | - Weixiong Weng
- School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen 518055, Guangdong, China; National-regional Key Technology Engineering Laboratory for Medical Ultrasound, Shenzhen University, Shenzhen 518055, Guangdong, China
| | - Mengting Chen
- School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen 518055, Guangdong, China; National-regional Key Technology Engineering Laboratory for Medical Ultrasound, Shenzhen University, Shenzhen 518055, Guangdong, China
| | - Haoqiang Huang
- School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen 518055, Guangdong, China; National-regional Key Technology Engineering Laboratory for Medical Ultrasound, Shenzhen University, Shenzhen 518055, Guangdong, China
| | - Xin Chen
- School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen 518055, Guangdong, China; National-regional Key Technology Engineering Laboratory for Medical Ultrasound, Shenzhen University, Shenzhen 518055, Guangdong, China
| | - Yin Peng
- School of Basic Medical Sciences, Shenzhen University Medical School, Shenzhen University, Shenzhen 518055, Guangdong, China
| | - Yaxin Hu
- School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen 518055, Guangdong, China; National-regional Key Technology Engineering Laboratory for Medical Ultrasound, Shenzhen University, Shenzhen 518055, Guangdong, China.
| |
Collapse
|
18
|
Souri M, Kiani Shahvandi M, Chiani M, Moradi Kashkooli F, Farhangi A, Mehrabi MR, Rahmim A, Savage VM, Soltani M. Stimuli-sensitive nano-drug delivery with programmable size changes to enhance accumulation of therapeutic agents in tumors. Drug Deliv 2023; 30:2186312. [PMID: 36895188 PMCID: PMC10013474 DOI: 10.1080/10717544.2023.2186312] [Citation(s) in RCA: 23] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/11/2023] Open
Abstract
Nano-based drug delivery systems hold significant promise for cancer therapies. Presently, the poor accumulation of drug-carrying nanoparticles in tumors has limited their success. In this study, based on a combination of the paradigms of intravascular and extravascular drug release, an efficient nanosized drug delivery system with programmable size changes is introduced. Drug-loaded smaller nanoparticles (secondary nanoparticles), which are loaded inside larger nanoparticles (primary nanoparticles), are released within the microvascular network due to temperature field resulting from focused ultrasound. This leads to the scale of the drug delivery system decreasing by 7.5 to 150 times. Subsequently, smaller nanoparticles enter the tissue at high transvascular rates and achieve higher accumulation, leading to higher penetration depths. In response to the acidic pH of tumor microenvironment (according to the distribution of oxygen), they begin to release the drug doxorubicin at very slow rates (i.e., sustained release). To predict the performance and distribution of therapeutic agents, a semi-realistic microvascular network is first generated based on a sprouting angiogenesis model and the transport of therapeutic agents is then investigated based on a developed multi-compartment model. The results show that reducing the size of the primary and secondary nanoparticles can lead to higher cell death rate. In addition, tumor growth can be inhibited for a longer time by enhancing the bioavailability of the drug in the extracellular space. The proposed drug delivery system can be very promising in clinical applications. Furthermore, the proposed mathematical model is applicable to broader applications to predict the performance of drug delivery systems.
Collapse
Affiliation(s)
- Mohammad Souri
- Department of NanoBiotechnology, Pasteur Institute of Iran, Tehran, Iran
| | | | - Mohsen Chiani
- Department of NanoBiotechnology, Pasteur Institute of Iran, Tehran, Iran
| | | | - Ali Farhangi
- Department of NanoBiotechnology, Pasteur Institute of Iran, Tehran, Iran
| | | | - Arman Rahmim
- Departments of Radiology and Physics, University of British Columbia, Vancouver, British Columbia, Canada.,Department of Integrative Oncology, BC Cancer Research Institute, Vancouver, British Columbia, Canada
| | - Van M Savage
- Department of Ecology and Evolutionary Biology, University of California Los Angeles, Los Angeles, California, USA.,Department of Computational Medicine, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, California, USA.,Santa Fe Institute, Santa Fe, New Mexico, USA
| | - M Soltani
- Department of Mechanical Engineering, K. N. Toosi University of Technology, Tehran, Iran.,Department of Electrical and Computer Engineering, University of Waterloo, Waterloo, Canada.,Centre for Biotechnology and Bioengineering (CBB), University of Waterloo, Waterloo, Canada.,Advanced Bioengineering Initiative Center, Multidisciplinary International Complex, K. N. Toosi University of Technology, Tehran, Iran
| |
Collapse
|
19
|
Shin DH, Son S, Kim EY. Low-Energy Transcranial Navigation-Guided Focused Ultrasound for Neuropathic Pain: An Exploratory Study. Brain Sci 2023; 13:1433. [PMID: 37891801 PMCID: PMC10605299 DOI: 10.3390/brainsci13101433] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2023] [Revised: 10/01/2023] [Accepted: 10/06/2023] [Indexed: 10/29/2023] Open
Abstract
Neuromodulation using high-energy focused ultrasound (FUS) has recently been developed for various neurological disorders, including tremors, epilepsy, and neuropathic pain. We investigated the safety and efficacy of low-energy FUS for patients with chronic neuropathic pain. We conducted a prospective single-arm trial with 3-month follow-up using new transcranial, navigation-guided, focused ultrasound (tcNgFUS) technology to stimulate the anterior cingulate cortex. Eleven patients underwent FUS with a frequency of 250 kHz and spatial-peak temporal-average intensity of 0.72 W/cm2. A clinical survey based on the visual analog scale of pain and a brief pain inventory (BPI) was performed during the study period. The average age was 60.55 ± 13.18 years-old with a male-to-female ratio of 6:5. The median current pain decreased from 10.0 to 7.0 (p = 0.021), median average pain decreased from 8.5 to 6.0 (p = 0.027), and median maximum pain decreased from 10.0 to 8.0 (p = 0.008) at 4 weeks after treatment. Additionally, the sum of daily life interference based on BPI was improved from 59.00 ± 11.66 to 51.91 ± 9.18 (p = 0.021). There were no side effects such as burns, headaches, or seizures, and no significant changes in follow-up brain magnetic resonance imaging. Low-energy tcNgFUS could be a safe and noninvasive neuromodulation technique for the treatment of chronic neuropathic pain.
Collapse
Affiliation(s)
- Dong Hoon Shin
- Department of Neurology, Gachon University Gil Medical Center, Incheon 21565, Republic of Korea;
| | - Seong Son
- Department of Neurosurgery, Gachon University Gil Medical Center, Incheon 21565, Republic of Korea;
| | - Eun Young Kim
- Department of Neurosurgery, Gachon University Gil Medical Center, Incheon 21565, Republic of Korea;
| |
Collapse
|
20
|
Javid A, Ilham S, Kiani M. A Review of Ultrasound Neuromodulation Technologies. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2023; 17:1084-1096. [PMID: 37506009 DOI: 10.1109/tbcas.2023.3299750] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/30/2023]
Abstract
The invasiveness of neuromodulation technologies that require surgical implantation (e.g., electrical and optical stimulation) may limit their clinical application. Thus, alternative technologies that offer similar benefits without surgery are of paramount importance in the field of neuromodulation. Low-intensity ultrasound is an emerging modality for neural stimulation as ultrasound can be focused in deep tissues with millimeter resolution. Transcranial focused ultrasound stimulation (tFUS) has already been demonstrated in a wide range of animals and even humans at different sonication frequencies (mostly in the sub-MHz range due to the presence of the skull). This article first provides some fundamental knowledge in ultrasound, and then reviews various examples of successful tFUS experiments in animals and humans using different stimulation patterns, as well as available tFUS technologies for generating, focusing, and steering ultrasound beams in neural tissues. In particular, phased array technologies for the ultrasound stimulation application are discussed with an emphasis on the design, fabrication, and integration of ultrasound transducer arrays as well as the design and development of phased array electronics with beamformer and high-voltage driver circuitry. The challenges in tFUS, such as its underlying mechanism, indirect auditory response, and skull aberration effects, are also discussed.
Collapse
|
21
|
Carey H, Pegios M, Martin L, Saleeba C, Turner AJ, Everett NA, Bjerke IE, Puchades MA, Bjaalie JG, McMullan S. DeepSlice: rapid fully automatic registration of mouse brain imaging to a volumetric atlas. Nat Commun 2023; 14:5884. [PMID: 37735467 PMCID: PMC10514056 DOI: 10.1038/s41467-023-41645-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2023] [Accepted: 09/12/2023] [Indexed: 09/23/2023] Open
Abstract
Registration of data to a common frame of reference is an essential step in the analysis and integration of diverse neuroscientific data. To this end, volumetric brain atlases enable histological datasets to be spatially registered and analyzed, yet accurate registration remains expertise-dependent and slow. In order to address this limitation, we have trained a neural network, DeepSlice, to register mouse brain histological images to the Allen Brain Common Coordinate Framework, retaining registration accuracy while improving speed by >1000 fold.
Collapse
Affiliation(s)
- Harry Carey
- Macquarie Medical School, Faculty of Medicine, Health & Human Sciences, Macquarie University, Marsfield, NSW, Australia
- Department of Molecular Medicine, Institute of Basic Medical Sciences, University of Oslo, Oslo, Norway
| | - Michael Pegios
- Macquarie Medical School, Faculty of Medicine, Health & Human Sciences, Macquarie University, Marsfield, NSW, Australia
| | | | - Chris Saleeba
- Macquarie Medical School, Faculty of Medicine, Health & Human Sciences, Macquarie University, Marsfield, NSW, Australia
| | - Anita J Turner
- Macquarie Medical School, Faculty of Medicine, Health & Human Sciences, Macquarie University, Marsfield, NSW, Australia
| | | | - Ingvild E Bjerke
- Department of Molecular Medicine, Institute of Basic Medical Sciences, University of Oslo, Oslo, Norway
| | - Maja A Puchades
- Department of Molecular Medicine, Institute of Basic Medical Sciences, University of Oslo, Oslo, Norway
| | - Jan G Bjaalie
- Department of Molecular Medicine, Institute of Basic Medical Sciences, University of Oslo, Oslo, Norway
| | - Simon McMullan
- Macquarie Medical School, Faculty of Medicine, Health & Human Sciences, Macquarie University, Marsfield, NSW, Australia.
| |
Collapse
|
22
|
Lee K, Lee JM, Phan TT, Lee CJ, Park JM, Park J. Ultrasonocoverslip: In-vitro platform for high-throughput assay of cell type-specific neuromodulation with ultra-low-intensity ultrasound stimulation. Brain Stimul 2023; 16:1533-1548. [PMID: 37909109 DOI: 10.1016/j.brs.2023.08.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2023] [Revised: 07/28/2023] [Accepted: 08/03/2023] [Indexed: 11/02/2023] Open
Abstract
Brain stimulation with ultra-low-intensity ultrasound has rarely been investigated due to the lack of a reliable device to measure small neuronal signal changes made by the ultra-low intensity range. We propose Ultrasonocoverslip, an ultrasound-transducer-integrated-glass-coverslip that determines the minimum intensity for brain cell activation. Brain cells can be cultured directly on Ultrasonocoverslip to simultaneously deliver uniform ultrasonic pressure to hundreds of cells with real-time monitoring of cellular responses using fluorescence microscopy and single-cell electrophysiology. The sensitivity for detecting small responses to ultra-low-intensity ultrasound can be improved by averaging simultaneously obtained responses. Acoustic absorbers can be placed under Ultrasonocoverslip, and stimuli distortions are substantially reduced to precisely deliver user-intended acoustic stimulations. With the proposed device, we discover the lowest acoustic threshold to induce reliable neuronal excitation releasing glutamate. Furthermore, mechanistic studies on the device show that the ultra-low-intensity ultrasound stimulation induces cell type-specific neuromodulation by activating astrocyte-mediated neuronal excitation without direct neuronal involvement. The performance of ultra-low-intensity stimulation is validated by in vivo experiments demonstrating improved safety and specificity in motor modulation of tail movement compared to that with supra-watt-intensity.
Collapse
Affiliation(s)
- Keunhyung Lee
- Department of Intelligent Precision Healthcare Convergence, Sungkyunkwan University, Suwon, Republic of Korea
| | - Jung Moo Lee
- Center for Cognition and Sociality, Institute for Basic Science, Daejeon, Republic of Korea
| | - Tien Thuy Phan
- IBS School, University of Science and Technology (UST), Daejeon, Republic of Korea
| | - C Justin Lee
- Center for Cognition and Sociality, Institute for Basic Science, Daejeon, Republic of Korea
| | - Joo Min Park
- Center for Cognition and Sociality, Institute for Basic Science, Daejeon, Republic of Korea; IBS School, University of Science and Technology (UST), Daejeon, Republic of Korea.
| | - Jinhyoung Park
- Department of Intelligent Precision Healthcare Convergence, Sungkyunkwan University, Suwon, Republic of Korea; Department of Biomedical Engineering, Sungkyunkwan University, Suwon, Republic of Korea.
| |
Collapse
|
23
|
Fan B, Goodman W, Cho RY, Sheth SA, Bouchard RR, Aazhang B. Computational modeling and minimization of unintended neuronal excitation in a LIFU stimulation. Sci Rep 2023; 13:13403. [PMID: 37591991 PMCID: PMC10435497 DOI: 10.1038/s41598-023-40522-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2023] [Accepted: 08/11/2023] [Indexed: 08/19/2023] Open
Abstract
The neuromodulation effect of low-intensity focused ultrasound (LIFU) is highly target-specific. Unintended off-target neuronal excitation can be elicited when the beam focusing accuracy and resolution are limited, whereas the resulted side effect has not been evaluated quantitatively. There is also a lack of methods addressing the minimization of such side effects. Therefore, this work introduces a computational model of unintended neuronal excitation during LIFU neuromodulation, which evaluates the off-target activation area (OTAA) by integrating an ultrasound field model with the neuronal spiking model. In addition, a phased array beam focusing scheme called constrained optimal resolution beamforming (CORB) is proposed to minimize the off-target neuronal excitation area while ensuring effective stimulation in the target brain region. A lower bound of the OTAA is analytically approximated in a simplified homogeneous medium, which could guide the selection of transducer parameters such as aperture size and operating frequency. Simulations in a human head model using three transducer setups show that CORB markedly reduces the OTAA compared with two benchmark beam focusing methods. The high neuromodulation resolution demonstrates the capability of LIFU to effectively limit the side effects during neuromodulation, allowing future clinical applications such as treatment of neuropsychiatric disorders.
Collapse
Affiliation(s)
- Boqiang Fan
- Department of Electrical and Computer Engineering, Rice University, Houston, TX, 77005, USA.
| | - Wayne Goodman
- Department of Electrical and Computer Engineering, Rice University, Houston, TX, 77005, USA
- Department of Psychiatry and Behavioral Science, Baylor College of Medicine, Houston, TX, 77030, USA
| | - Raymond Y Cho
- Department of Psychiatry and Behavioral Science, Baylor College of Medicine, Houston, TX, 77030, USA
| | - Sameer A Sheth
- Department of Electrical and Computer Engineering, Rice University, Houston, TX, 77005, USA
- Department of Neurosurgery, Baylor College of Medicine, Houston, TX, 77030, USA
| | - Richard R Bouchard
- Department of Imaging Physics, University of Texas MD Anderson Cancer Center, Houston, TX, 77030, USA
| | - Behnaam Aazhang
- Department of Electrical and Computer Engineering, Rice University, Houston, TX, 77005, USA
| |
Collapse
|
24
|
Kim S, Jo Y, Im GH, Lee C, Oh C, Kook G, Kim SG, Lee HJ. Miniaturized MR-compatible ultrasound system for real-time monitoring of acoustic effects in mice using high-resolution MRI. Neuroimage 2023; 276:120201. [PMID: 37269955 DOI: 10.1016/j.neuroimage.2023.120201] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2023] [Revised: 05/24/2023] [Accepted: 05/26/2023] [Indexed: 06/05/2023] Open
Abstract
Visualization of focused ultrasound in high spatial and temporal resolution is crucial for accurately and precisely targeting brain regions noninvasively. Magnetic resonance imaging (MRI) is the most widely used noninvasive tool for whole-brain imaging. However, focused ultrasound studies employing high-resolution (> 9.4 T) MRI in small animals are limited by the small size of the radiofrequency (RF) volume coil and the noise sensitivity of the image to external systems such as bulky ultrasound transducers. This technical note reports a miniaturized ultrasound transducer system packaged directly above a mouse brain for monitoring ultrasound-induced effects using high-resolution 9.4 T MRI. Our miniaturized system integrates MR-compatible materials with electromagnetic (EM) noise reduction techniques to demonstrate echo-planar imaging (EPI) signal changes in the mouse brain at various ultrasound acoustic intensities. The proposed ultrasound-MRI system will enable extensive research in the expanding field of ultrasound therapeutics.
Collapse
Affiliation(s)
- Subeen Kim
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, South Korea
| | - Yehhyun Jo
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, South Korea
| | - Geun Ho Im
- Center for Neuroscience Imaging Research, Institute for Basic Science (IBS), Suwon 16419, South Korea
| | - Chanhee Lee
- Center for Neuroscience Imaging Research, Institute for Basic Science (IBS), Suwon 16419, South Korea
| | - Chaerin Oh
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, South Korea
| | - Geon Kook
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, South Korea
| | - Seong-Gi Kim
- Center for Neuroscience Imaging Research, Institute for Basic Science (IBS), Suwon 16419, South Korea; Department of Biomedical Engineering, Sungkyunkwan University, Suwon 16419, South Korea; Department of Intelligent Precision Healthcare Convergence, Sungkyunkwan University, Suwon 16419, South Korea.
| | - Hyunjoo J Lee
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, South Korea; KAIST Institute for Nano Century (KINC), Daejeon 34141, South Korea.
| |
Collapse
|
25
|
Shin EJ, Park S, Kang S, Kim J, Chang JH. Improving the quality of ultrasound images acquired using a therapeutic transducer. ULTRASONICS 2023; 134:107063. [PMID: 37300907 DOI: 10.1016/j.ultras.2023.107063] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/24/2023] [Revised: 05/01/2023] [Accepted: 05/30/2023] [Indexed: 06/12/2023]
Abstract
To enhance the effectiveness and safety of focused ultrasound (FUS) therapy, ultrasound image-based guidance and treatment monitoring are crucial. However, the use of FUS transducers for both therapy and imaging is impractical due to their low spatial resolution, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). To address this issue, we propose a new method that significantly improve the quality of images obtained by a FUS transducer. The proposed method employs coded excitation to enhance SNR and Wiener deconvolution to solve the problem of low axial resolution resulting from the narrow spectral bandwidth of FUS transducers. Specifically, the method eliminates the impulse response of a FUS transducer from received ultrasound signals using Wiener deconvolution, and pulse compression is performed using a mismatched filter. Simulation and commercial phantom experiments confirmed that the proposed method significantly improves the quality of images acquired by the FUS transducer. The -6 dB axial resolution was improved 1.27 mm to 0.37 mm that was similar to the resolution achieved by the imaging transducer, i.e., 0.33 mm. SNR and CNR also increased from 16.5 dB and 0.69 to 29.1 dB and 3.03, respectively, that were also similar to those by the imaging transducer (27.8 dB and 3.16). Based on the results, we believe that the proposed method has great potential to enhance the clinical utility of FUS transducers in ultrasound image-guided therapy.
Collapse
Affiliation(s)
- Eui-Ji Shin
- Department of Electronic Engineering, Sogang University, Seoul, Korea
| | - Sunghun Park
- Department of Electronic Engineering, Sogang University, Seoul, Korea
| | - Sungwoo Kang
- Department of Electrical Engineering and Computer Science, DGIST (Daegu Gyeongbuk Institute of Science and Technology), Daegu, Korea
| | - Jinwoo Kim
- Department of Electrical Engineering and Computer Science, DGIST (Daegu Gyeongbuk Institute of Science and Technology), Daegu, Korea
| | - Jin Ho Chang
- Department of Electrical Engineering and Computer Science, DGIST (Daegu Gyeongbuk Institute of Science and Technology), Daegu, Korea.
| |
Collapse
|
26
|
Cadoni S, Demené C, Alcala I, Provansal M, Nguyen D, Nelidova D, Labernède G, Lubetzki J, Goulet R, Burban E, Dégardin J, Simonutti M, Gauvain G, Arcizet F, Marre O, Dalkara D, Roska B, Sahel JA, Tanter M, Picaud S. Ectopic expression of a mechanosensitive channel confers spatiotemporal resolution to ultrasound stimulations of neurons for visual restoration. NATURE NANOTECHNOLOGY 2023; 18:667-676. [PMID: 37012508 DOI: 10.1038/s41565-023-01359-6] [Citation(s) in RCA: 29] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/12/2021] [Accepted: 02/13/2023] [Indexed: 06/18/2023]
Abstract
Remote and precisely controlled activation of the brain is a fundamental challenge in the development of brain-machine interfaces for neurological treatments. Low-frequency ultrasound stimulation can be used to modulate neuronal activity deep in the brain, especially after expressing ultrasound-sensitive proteins. But so far, no study has described an ultrasound-mediated activation strategy whose spatiotemporal resolution and acoustic intensity are compatible with the mandatory needs of brain-machine interfaces, particularly for visual restoration. Here we combined the expression of large-conductance mechanosensitive ion channels with uncustomary high-frequency ultrasonic stimulation to activate retinal or cortical neurons over millisecond durations at a spatiotemporal resolution and acoustic energy deposit compatible with vision restoration. The in vivo sonogenetic activation of the visual cortex generated a behaviour associated with light perception. Our findings demonstrate that sonogenetics can deliver millisecond pattern presentations via an approach less invasive than current brain-machine interfaces for visual restoration.
Collapse
Affiliation(s)
- Sara Cadoni
- Sorbonne Université, INSERM, CNRS, Institut de la Vision, Paris, France
| | - Charlie Demené
- Physics for Medicine Paris, INSERM, CNRS, École Supérieure de Physique et de Chimie Industrielles (ESPCI Paris), Paris Sciences et Lettres (PSL) Research University, Paris, France
| | - Ignacio Alcala
- Sorbonne Université, INSERM, CNRS, Institut de la Vision, Paris, France
| | | | - Diep Nguyen
- Sorbonne Université, INSERM, CNRS, Institut de la Vision, Paris, France
| | - Dasha Nelidova
- Institute of Molecular and Clinical Ophthalmology Basel, Basel, Switzerland
| | | | - Jules Lubetzki
- Sorbonne Université, INSERM, CNRS, Institut de la Vision, Paris, France
| | - Ruben Goulet
- Sorbonne Université, INSERM, CNRS, Institut de la Vision, Paris, France
| | - Emma Burban
- Sorbonne Université, INSERM, CNRS, Institut de la Vision, Paris, France
| | - Julie Dégardin
- Sorbonne Université, INSERM, CNRS, Institut de la Vision, Paris, France
| | - Manuel Simonutti
- Sorbonne Université, INSERM, CNRS, Institut de la Vision, Paris, France
| | - Gregory Gauvain
- Sorbonne Université, INSERM, CNRS, Institut de la Vision, Paris, France
| | - Fabrice Arcizet
- Sorbonne Université, INSERM, CNRS, Institut de la Vision, Paris, France
| | - Olivier Marre
- Sorbonne Université, INSERM, CNRS, Institut de la Vision, Paris, France
| | - Deniz Dalkara
- Sorbonne Université, INSERM, CNRS, Institut de la Vision, Paris, France
| | - Botond Roska
- Institute of Molecular and Clinical Ophthalmology Basel, Basel, Switzerland
| | - José Alain Sahel
- Sorbonne Université, INSERM, CNRS, Institut de la Vision, Paris, France
- Department of Ophthalmology, The University of Pittsburgh School of Medicine, Pittsburgh, PA, USA
- Department of Ophthalmology and Vitreo-Retinal Diseases, Fondation Ophtalmologique Rothschild, Paris, France
- Centre Hospitalier National d'Ophtalmologie des XV-XX, Paris, France
| | - Mickael Tanter
- Physics for Medicine Paris, INSERM, CNRS, École Supérieure de Physique et de Chimie Industrielles (ESPCI Paris), Paris Sciences et Lettres (PSL) Research University, Paris, France
| | - Serge Picaud
- Sorbonne Université, INSERM, CNRS, Institut de la Vision, Paris, France.
| |
Collapse
|
27
|
Chen X, Gong Y, Chen W. Advanced Temporally-Spatially Precise Technologies for On-Demand Neurological Disorder Intervention. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2023; 10:e2207436. [PMID: 36929323 PMCID: PMC10190591 DOI: 10.1002/advs.202207436] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Revised: 02/18/2023] [Indexed: 05/18/2023]
Abstract
Temporal-spatial precision has attracted increasing attention for the clinical intervention of neurological disorders (NDs) to mitigate adverse effects of traditional treatments and achieve point-of-care medicine. Inspiring steps forward in this field have been witnessed in recent years, giving the credit to multi-discipline efforts from neurobiology, bioengineering, chemical materials, artificial intelligence, and so on, exhibiting valuable clinical translation potential. In this review, the latest progress in advanced temporally-spatially precise clinical intervention is highlighted, including localized parenchyma drug delivery, precise neuromodulation, as well as biological signal detection to trigger closed-loop control. Their clinical potential in both central and peripheral nervous systems is illustrated meticulously related to typical diseases. The challenges relative to biosafety and scaled production as well as their future perspectives are also discussed in detail. Notably, these intelligent temporally-spatially precision intervention systems could lead the frontier in the near future, demonstrating significant clinical value to support billions of patients plagued with NDs.
Collapse
Affiliation(s)
- Xiuli Chen
- Department of Pharmacology, School of Basic MedicineTongji Medical CollegeHuazhong University of Science and Technology430030WuhanChina
- Hubei Key Laboratory of Drug Target Research and Pharmacodynamic EvaluationHuazhong University of Science and Technology430030WuhanChina
| | - Yusheng Gong
- Department of Pharmacology, School of Basic MedicineTongji Medical CollegeHuazhong University of Science and Technology430030WuhanChina
- Hubei Key Laboratory of Drug Target Research and Pharmacodynamic EvaluationHuazhong University of Science and Technology430030WuhanChina
| | - Wei Chen
- Department of Pharmacology, School of Basic MedicineTongji Medical CollegeHuazhong University of Science and Technology430030WuhanChina
- Hubei Key Laboratory of Drug Target Research and Pharmacodynamic EvaluationHuazhong University of Science and Technology430030WuhanChina
| |
Collapse
|
28
|
Kook G, Jo Y, Oh C, Liang X, Kim J, Lee SM, Kim S, Choi JW, Lee HJ. Multifocal skull-compensated transcranial focused ultrasound system for neuromodulation applications based on acoustic holography. MICROSYSTEMS & NANOENGINEERING 2023; 9:45. [PMID: 37056421 PMCID: PMC10085992 DOI: 10.1038/s41378-023-00513-3] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/09/2022] [Revised: 01/20/2023] [Accepted: 02/14/2023] [Indexed: 06/05/2023]
Abstract
Transcranial focused ultrasound stimulation is a promising therapeutic modality for human brain disorders because of its noninvasiveness, long penetration depth, and versatile spatial control capability through beamforming and beam steering. However, the skull presents a major hurdle for successful applications of ultrasound stimulation. Specifically, skull-induced focal aberration limits the capability for accurate and versatile targeting of brain subregions. In addition, there lacks a fully functional preclinical neuromodulation system suitable to conduct behavioral studies. Here, we report a miniature ultrasound system for neuromodulation applications that is capable of highly accurate multiregion targeting based on acoustic holography. Our work includes the design and implementation of an acoustic lens for targeting brain regions with compensation for skull aberration through time-reversal recording and a phase conjugation mirror. Moreover, we utilize MEMS and 3D-printing technology to implement a 0.75-g lightweight neuromodulation system and present in vivo characterization of the packaged system in freely moving mice. This preclinical system is capable of accurately targeting the desired individual or multitude of brain regions, which will enable versatile and explorative behavior studies using ultrasound neuromodulation to facilitate widespread clinical adoption.
Collapse
Affiliation(s)
- Geon Kook
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon, 34141 South Korea
| | - Yehhyun Jo
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon, 34141 South Korea
| | - Chaerin Oh
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon, 34141 South Korea
| | - Xiaojia Liang
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon, 34141 South Korea
| | - Jaewon Kim
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon, 34141 South Korea
| | - Sang-Mok Lee
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon, 34141 South Korea
| | - Subeen Kim
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon, 34141 South Korea
| | - Jung-Woo Choi
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon, 34141 South Korea
| | - Hyunjoo Jenny Lee
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon, 34141 South Korea
- KAIST Institute for NanoCentury (KINC), 291 Daehak-ro, Yuseong-gu, Daejeon, 34141 Republic of Korea
| |
Collapse
|
29
|
Hu Y, Wei J, Shen Y, Chen S, Chen X. Barrier-breaking effects of ultrasonic cavitation for drug delivery and biomarker release. ULTRASONICS SONOCHEMISTRY 2023; 94:106346. [PMID: 36870921 PMCID: PMC10040969 DOI: 10.1016/j.ultsonch.2023.106346] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/16/2023] [Revised: 02/15/2023] [Accepted: 02/23/2023] [Indexed: 05/27/2023]
Abstract
Recently, emerging evidence has demonstrated that cavitation actually creates important bidirectional channels on biological barriers for both intratumoral drug delivery and extratumoral biomarker release. To promote the barrier-breaking effects of cavitation for both therapy and diagnosis, we first reviewed recent technical advances of ultrasound and its contrast agents (microbubbles, nanodroplets, and gas-stabilizing nanoparticles) and then reported the newly-revealed cavitation physical details. In particular, we summarized five types of cellular responses of cavitation in breaking the plasma membrane (membrane retraction, sonoporation, endocytosis/exocytosis, blebbing and apoptosis) and compared the vascular cavitation effects of three different types of ultrasound contrast agents in breaking the blood-tumor barrier and tumor microenvironment. Moreover, we highlighted the current achievements of the barrier-breaking effects of cavitation in mediating drug delivery and biomarker release. We emphasized that the precise induction of a specific cavitation effect for barrier-breaking was still challenged by the complex combination of multiple acoustic and non-acoustic cavitation parameters. Therefore, we provided the cutting-edge in-situ cavitation imaging and feedback control methods and suggested the development of an international cavitation quantification standard for the clinical guidance of cavitation-mediated barrier-breaking effects.
Collapse
Affiliation(s)
- Yaxin Hu
- School of Biomedical Engineering, Medical School, Shenzhen University, Shenzhen, Guangdong, 518060, PR China; National-regional Key Technology Engineering Laboratory for Medical Ultrasound, Shenzhen University, Shenzhen, Guangdong, 518060, PR China
| | - Jianpeng Wei
- School of Biomedical Engineering, Medical School, Shenzhen University, Shenzhen, Guangdong, 518060, PR China; National-regional Key Technology Engineering Laboratory for Medical Ultrasound, Shenzhen University, Shenzhen, Guangdong, 518060, PR China
| | - Yuanyuan Shen
- School of Biomedical Engineering, Medical School, Shenzhen University, Shenzhen, Guangdong, 518060, PR China; National-regional Key Technology Engineering Laboratory for Medical Ultrasound, Shenzhen University, Shenzhen, Guangdong, 518060, PR China
| | - Siping Chen
- School of Biomedical Engineering, Medical School, Shenzhen University, Shenzhen, Guangdong, 518060, PR China; National-regional Key Technology Engineering Laboratory for Medical Ultrasound, Shenzhen University, Shenzhen, Guangdong, 518060, PR China
| | - Xin Chen
- School of Biomedical Engineering, Medical School, Shenzhen University, Shenzhen, Guangdong, 518060, PR China; National-regional Key Technology Engineering Laboratory for Medical Ultrasound, Shenzhen University, Shenzhen, Guangdong, 518060, PR China.
| |
Collapse
|
30
|
Mazzotti M, Kohtanen E, Erturk A, Ruzzene M. Optimizing transcranial ultrasound delivery at large incident angles by leveraging cranial leaky guided wave dispersion. ULTRASONICS 2023; 128:106882. [PMID: 36402116 DOI: 10.1016/j.ultras.2022.106882] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/05/2022] [Revised: 09/08/2022] [Accepted: 10/19/2022] [Indexed: 06/16/2023]
Abstract
We investigate the role of leaky guided waves in transcranial ultrasound transmission in temporal and parietal bones at large incidence angles. Our numerical and experimental results show that the dispersion characteristics of the fundamental leaky guided wave mode with longitudinal polarization can be leveraged to estimate the critical angle above which efficient shear mode conversion takes place, and below which major transmission drops can be expected. Simulations that employ a numerical propagator matrix and a Semi-Analytical approach establish the transcranial dispersion characteristics and transmission coefficients at different incident angles. Experimental transmission tests conducted at 500 kHz and radiation tests performed in the 200-800 kHz range confirm the numerical findings in terms of transmitted peak pressure and frequency-radiation angle spectra, based on which the connection between critical angles, dispersion and transmission is demonstrated. Our results support the identification of transcranial ultrasound strategies that leverage shear mode conversion, which is less sensitive to phase aberrations compared to normal incidence ultrasound. These findings can also enable higher transmission rates in cranial bones with low porosity by leveraging dispersion information extracted through signal processing, without requiring measurement of geometric and mechanical properties of the cranial bone.
Collapse
Affiliation(s)
- Matteo Mazzotti
- P.M. Rady Department of Mechanical Engineering, University of Colorado Boulder, Boulder, USA.
| | - Eetu Kohtanen
- G.W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, USA
| | - Alper Erturk
- G.W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, USA
| | - Massimo Ruzzene
- P.M. Rady Department of Mechanical Engineering, University of Colorado Boulder, Boulder, USA
| |
Collapse
|
31
|
Hu YY, Yang G, Liang XS, Ding XS, Xu DE, Li Z, Ma QH, Chen R, Sun YY. Transcranial low-intensity ultrasound stimulation for treating central nervous system disorders: A promising therapeutic application. Front Neurol 2023; 14:1117188. [PMID: 36970512 PMCID: PMC10030814 DOI: 10.3389/fneur.2023.1117188] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2022] [Accepted: 02/10/2023] [Indexed: 03/29/2023] Open
Abstract
Transcranial ultrasound stimulation is a neurostimulation technique that has gradually attracted the attention of researchers, especially as a potential therapy for neurological disorders, because of its high spatial resolution, its good penetration depth, and its non-invasiveness. Ultrasound can be categorized as high-intensity and low-intensity based on the intensity of its acoustic wave. High-intensity ultrasound can be used for thermal ablation by taking advantage of its high-energy characteristics. Low-intensity ultrasound, which produces low energy, can be used as a means to regulate the nervous system. The present review describes the current status of research on low-intensity transcranial ultrasound stimulation (LITUS) in the treatment of neurological disorders, such as epilepsy, essential tremor, depression, Parkinson's disease (PD), and Alzheimer's disease (AD). This review summarizes preclinical and clinical studies using LITUS to treat the aforementioned neurological disorders and discusses their underlying mechanisms.
Collapse
Affiliation(s)
- Yun-Yun Hu
- Department of Neurology and Clinical Research Center of Neurological Disease, The Second Affiliated Hospital of Soochow University, Suzhou, China
- Jiangsu Key Laboratory of Neuropsychiatric Diseases, Institute of Neuroscience, Soochow University, Suzhou, Jiangsu, China
| | - Gang Yang
- Lab Center, Medical College of Soochow University, Suzhou, China
| | - Xue-Song Liang
- Department of Neurology and Clinical Research Center of Neurological Disease, The Second Affiliated Hospital of Soochow University, Suzhou, China
- Jiangsu Key Laboratory of Neuropsychiatric Diseases, Institute of Neuroscience, Soochow University, Suzhou, Jiangsu, China
- Second Clinical College, Dalian Medical University, Dalian, Liaoning, China
| | - Xuan-Si Ding
- Department of Neurology and Clinical Research Center of Neurological Disease, The Second Affiliated Hospital of Soochow University, Suzhou, China
- Jiangsu Key Laboratory of Neuropsychiatric Diseases, Institute of Neuroscience, Soochow University, Suzhou, Jiangsu, China
| | - De-En Xu
- Wuxi No. 2 People's Hospital, Wuxi, Jiangsu, China
| | - Zhe Li
- Department of Neurology and Clinical Research Center of Neurological Disease, The Second Affiliated Hospital of Soochow University, Suzhou, China
- Sleep Medicine Center, Suzhou Guangji Hospital, The Affiliated Guangji Hospital of Soochow University, Suzhou, China
| | - Quan-Hong Ma
- Department of Neurology and Clinical Research Center of Neurological Disease, The Second Affiliated Hospital of Soochow University, Suzhou, China
- Jiangsu Key Laboratory of Neuropsychiatric Diseases, Institute of Neuroscience, Soochow University, Suzhou, Jiangsu, China
- Quan-Hong Ma
| | - Rui Chen
- Department of Neurology and Clinical Research Center of Neurological Disease, The Second Affiliated Hospital of Soochow University, Suzhou, China
- *Correspondence: Rui Chen
| | - Yan-Yun Sun
- Department of Neurology and Clinical Research Center of Neurological Disease, The Second Affiliated Hospital of Soochow University, Suzhou, China
- Jiangsu Key Laboratory of Neuropsychiatric Diseases, Institute of Neuroscience, Soochow University, Suzhou, Jiangsu, China
- Yan-Yun Sun
| |
Collapse
|
32
|
Multifrequency-based sharpening of focal volume. Sci Rep 2022; 12:22049. [PMID: 36543884 PMCID: PMC9772409 DOI: 10.1038/s41598-022-25886-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2022] [Accepted: 12/06/2022] [Indexed: 12/24/2022] Open
Abstract
Systems that emit electromagnetic or sonic waves for diagnostic or interventional applications often have constraints on the size of their aperture, and thus produce an elongated focus in the axial dimension. This extended depth of focus limits imaging resolution and spatial specificity of the delivered energy. Here, we have developed a method that substantially minimizes the depth of focus. The method superimposes beams of distinct frequencies in space and time to create constructive interference at target and amplify deconstructive interference everywhere else, thus sharpening the focus. The method does not require labeling of targets or other manipulations of the medium. Using simulations, we found that the method tightens the depth of focus even for systems with a narrow bandwidth. Moreover, we implemented the method in ultrasonic hardware and found that a 46.1% frequency fractional bandwidth provides an average 7.4-fold reduction in the focal volume of the resulting beams. This method can be readily applied to sharpen the focus of interventional systems and is expected to also improve the axial resolution of existing imaging systems.
Collapse
|
33
|
Jo Y, Lee S, Jung T, Park G, Lee C, Im GH, Lee S, Park JS, Oh C, Kook G, Kim H, Kim S, Lee BC, Suh GS, Kim S, Kim J, Lee HJ. General-Purpose Ultrasound Neuromodulation System for Chronic, Closed-Loop Preclinical Studies in Freely Behaving Rodents. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2022; 9:e2202345. [PMID: 36259285 PMCID: PMC9731702 DOI: 10.1002/advs.202202345] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/23/2022] [Revised: 08/20/2022] [Indexed: 05/11/2023]
Abstract
Transcranial focused ultrasound stimulation (tFUS) is an effective noninvasive treatment modality for brain disorders with high clinical potential. However, the therapeutic effects of ultrasound neuromodulation are not widely explored due to limitations in preclinical systems. The current preclinical studies are head-fixed, anesthesia-dependent, and acute, limiting clinical translatability. Here, this work reports a general-purpose ultrasound neuromodulation system for chronic, closed-loop preclinical studies in freely behaving rodents. This work uses microelectromechanical systems (MEMS) technology to design and fabricate a small and lightweight transducer capable of artifact-free stimulation and simultaneous neural recording. Using the general-purpose system, it can be observed that state-dependent ultrasound neuromodulation of the prefrontal cortex increases rapid eye movement (REM) sleep and protects spatial working memory to REM sleep deprivation. The system will allow explorative studies in brain disease therapeutics and neuromodulation using ultrasound stimulation for widespread clinical adoption.
Collapse
Affiliation(s)
- Yehhyun Jo
- School of Electrical EngineeringKorea Advanced Institute of Science and Technology (KAIST)Daejeon34141Republic of Korea
| | - Sang‐Mok Lee
- School of Electrical EngineeringKorea Advanced Institute of Science and Technology (KAIST)Daejeon34141Republic of Korea
| | - Taesub Jung
- Korea Brain Research Institute (KBRI)Daegu41068Republic of Korea
| | - Gijae Park
- Department of Electrical EngineeringKorea UniversitySeoul02841Republic of Korea
| | - Chanhee Lee
- Center for Neuroscience Imaging ResearchInstitute for Basic ScienceSuwon16419Republic of Korea
| | - Geun Ho Im
- Center for Neuroscience Imaging ResearchInstitute for Basic ScienceSuwon16419Republic of Korea
| | - Seongju Lee
- Department of Biological SciencesKorea Advanced Institute of Science and Technology (KAIST)Daejeon34141Republic of Korea
| | - Jin Soo Park
- Department of Electrical EngineeringKorea UniversitySeoul02841Republic of Korea
- Creative Research Center for Brain ScienceKorea Institute of Science and Technology (KIST)Seoul02792Republic of Korea
| | - Chaerin Oh
- School of Electrical EngineeringKorea Advanced Institute of Science and Technology (KAIST)Daejeon34141Republic of Korea
| | - Geon Kook
- School of Electrical EngineeringKorea Advanced Institute of Science and Technology (KAIST)Daejeon34141Republic of Korea
| | - Hyunggug Kim
- School of Electrical EngineeringKorea Advanced Institute of Science and Technology (KAIST)Daejeon34141Republic of Korea
| | - Seongyeon Kim
- School of Electrical EngineeringKorea Advanced Institute of Science and Technology (KAIST)Daejeon34141Republic of Korea
| | - Byung Chul Lee
- Creative Research Center for Brain ScienceKorea Institute of Science and Technology (KIST)Seoul02792Republic of Korea
| | - Greg S.B. Suh
- Department of Biological SciencesKorea Advanced Institute of Science and Technology (KAIST)Daejeon34141Republic of Korea
| | - Seong‐Gi Kim
- Center for Neuroscience Imaging ResearchInstitute for Basic ScienceSuwon16419Republic of Korea
- Department of Biomedical EngineeringSungkyunkwan UniversitySuwon16419Republic of Korea
- Department of Intelligent Precision Healthcare ConvergenceSungkyunkwan UniversitySuwon16419Republic of Korea
| | - Jeongyeon Kim
- Korea Brain Research Institute (KBRI)Daegu41068Republic of Korea
| | - Hyunjoo J. Lee
- School of Electrical EngineeringKorea Advanced Institute of Science and Technology (KAIST)Daejeon34141Republic of Korea
- KAIST Institute for Health Science and Technology (KIHST)Daejeon34141Republic of Korea
| |
Collapse
|
34
|
Li Y, Jiang Y, Lan L, Ge X, Cheng R, Zhan Y, Chen G, Shi L, Wang R, Zheng N, Yang C, Cheng JX. Optically-generated focused ultrasound for noninvasive brain stimulation with ultrahigh precision. LIGHT, SCIENCE & APPLICATIONS 2022; 11:321. [PMID: 36323662 PMCID: PMC9630534 DOI: 10.1038/s41377-022-01004-2] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Revised: 09/29/2022] [Accepted: 10/07/2022] [Indexed: 06/01/2023]
Abstract
High precision neuromodulation is a powerful tool to decipher neurocircuits and treat neurological diseases. Current non-invasive neuromodulation methods offer limited precision at the millimeter level. Here, we report optically-generated focused ultrasound (OFUS) for non-invasive brain stimulation with ultrahigh precision. OFUS is generated by a soft optoacoustic pad (SOAP) fabricated through embedding candle soot nanoparticles in a curved polydimethylsiloxane film. SOAP generates a transcranial ultrasound focus at 15 MHz with an ultrahigh lateral resolution of 83 µm, which is two orders of magnitude smaller than that of conventional transcranial-focused ultrasound (tFUS). Here, we show effective OFUS neurostimulation in vitro with a single ultrasound cycle. We demonstrate submillimeter transcranial stimulation of the mouse motor cortex in vivo. An acoustic energy of 0.6 mJ/cm2, four orders of magnitude less than that of tFUS, is sufficient for successful OFUS neurostimulation. OFUS offers new capabilities for neuroscience studies and disease treatments by delivering a focus with ultrahigh precision non-invasively.
Collapse
Affiliation(s)
- Yueming Li
- Department of Mechanical Engineering, Boston University, Boston, MA, 02215, USA
| | - Ying Jiang
- Graduate Program for Neuroscience, Boston University, Boston, MA, 02215, USA
- Department of Biological Engineering, Massachusetts Institute of Technology, Cambridge, MA, 02142, USA
| | - Lu Lan
- Department of Electrical and Computer Engineering, Boston University, Boston, MA, 02215, USA
| | - Xiaowei Ge
- Department of Electrical and Computer Engineering, Boston University, Boston, MA, 02215, USA
| | - Ran Cheng
- Department of Chemistry, Boston University, Boston, MA, 02215, USA
| | - Yuewei Zhan
- Department of Biomedical Engineering, Boston University, Boston, MA, 02215, USA
| | - Guo Chen
- Department of Electrical and Computer Engineering, Boston University, Boston, MA, 02215, USA
| | - Linli Shi
- Department of Chemistry, Boston University, Boston, MA, 02215, USA
| | - Runyu Wang
- Department of Electrical and Computer Engineering, Boston University, Boston, MA, 02215, USA
| | - Nan Zheng
- Division of Materials Science and Engineering, Boston University, Boston, MA, 02215, USA
| | - Chen Yang
- Department of Electrical and Computer Engineering, Boston University, Boston, MA, 02215, USA.
- Department of Chemistry, Boston University, Boston, MA, 02215, USA.
| | - Ji-Xin Cheng
- Department of Electrical and Computer Engineering, Boston University, Boston, MA, 02215, USA.
- Department of Biomedical Engineering, Boston University, Boston, MA, 02215, USA.
| |
Collapse
|
35
|
Kim E, Van Reet J, Kim HC, Kowsari K, Yoo SS. High Incidence of Intracerebral Hemorrhaging Associated with the Application of Low-Intensity Focused Ultrasound Following Acute Cerebrovascular Injury by Intracortical Injection. Pharmaceutics 2022; 14:2120. [PMID: 36297554 PMCID: PMC9609794 DOI: 10.3390/pharmaceutics14102120] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Revised: 09/22/2022] [Accepted: 10/04/2022] [Indexed: 11/29/2022] Open
Abstract
Low-intensity transcranial focused ultrasound (FUS) has gained momentum as a non-/minimally-invasive modality that facilitates the delivery of various pharmaceutical agents to the brain. With the additional ability to modulate regional brain tissue excitability, FUS is anticipated to confer potential neurotherapeutic applications whereby a deeper insight of its safety is warranted. We investigated the effects of FUS applied to the rat brain (Sprague-Dawley) shortly after an intracortical injection of fluorescent interstitial solutes, a widely used convection-enhanced delivery technique that directly (i.e., bypassing the blood-brain-barrier (BBB)) introduces drugs or interstitial tracers to the brain parenchyma. Texas Red ovalbumin (OA) and fluorescein isothiocyanate-dextran (FITC-d) were used as the interstitial tracers. Rats that did not receive sonication showed an expected interstitial distribution of OA and FITC-d around the injection site, with a wider volume distribution of OA (21.8 ± 4.0 µL) compared to that of FITC-d (7.8 ± 2.7 µL). Remarkably, nearly half of the rats exposed to the FUS developed intracerebral hemorrhaging (ICH), with a significantly higher volume of bleeding compared to a minor red blood cell extravasation from the animals that were not exposed to sonication. This finding suggests that the local cerebrovascular injury inflicted by the micro-injection was further exacerbated by the application of sonication, particularly during the acute stage of injury. Smaller tracer volume distributions and weaker fluorescent intensities, compared to the unsonicated animals, were observed for the sonicated rats that did not manifest hemorrhaging, which may indicate an enhanced degree of clearance of the injected tracers. Our results call for careful safety precautions when ultrasound sonication is desired among groups under elevated risks associated with a weakened or damaged vascular integrity.
Collapse
Affiliation(s)
- Evgenii Kim
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA 02115, USA or
| | - Jared Van Reet
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA 02115, USA or
| | - Hyun-Chul Kim
- Department of Artificial Intelligence, Kyungpook National University, Daegu 37224, Korea
| | - Kavin Kowsari
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA 02115, USA or
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Seung-Schik Yoo
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA 02115, USA or
| |
Collapse
|
36
|
Kim E, Kum J, Lee SH, Kim H. Development of a wireless ultrasonic brain stimulation system for concurrent bilateral neuromodulation in freely moving rodents. Front Neurosci 2022; 16:1011699. [PMID: 36213731 PMCID: PMC9539445 DOI: 10.3389/fnins.2022.1011699] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2022] [Accepted: 08/31/2022] [Indexed: 11/13/2022] Open
Abstract
Bilateral brain stimulation is an important modality used to investigate brain circuits and treat neurological conditions. Recently, low-intensity pulsed ultrasound (LIPUS) received significant attention as a novel non-invasive neurostimulation technique with high spatial specificity. Despite the growing interest, the typical ultrasound brain stimulation study, especially for small animals, is limited to a single target of sonication. The constraint is associated with the complexity and the cost of the hardware system required to achieve multi-regional sonication. This work presented the development of a low-cost LIPUS system with a pair of single-element ultrasound transducers to address the above problem. The system was built with a multicore processor with an RF amplifier circuit. In addition, LIPUS device was incorporated with a wireless module (bluetooth low energy) and powered by a single 3.7 V battery. As a result, we achieved an ultrasound transmission with a central frequency of 380 kHz and a peak-to-peak pressure of 480 kPa from each ultrasound transducer. The developed system was further applied to anesthetized rats to investigate the difference between uni- and bilateral stimulation. A significant difference in cortical power density extracted from electroencephalogram signals was observed between uni- and bilateral LIPUS stimulation. The developed device provides an affordable solution to investigate the effects of LIPUS on functional interhemispheric connection.
Collapse
Affiliation(s)
- Evgenii Kim
- Biomedical Research Division, Bionics Research Center, Korea Institute of Science and Technology, Seoul, South Korea
| | - Jeungeun Kum
- Biomedical Research Division, Bionics Research Center, Korea Institute of Science and Technology, Seoul, South Korea
- Division of Bio-Medical Science and Technology, KIST School, Korea University of Science and Technology, Seoul, South Korea
| | - Seung Hyun Lee
- Biomedical Research Division, Bionics Research Center, Korea Institute of Science and Technology, Seoul, South Korea
| | - Hyungmin Kim
- Biomedical Research Division, Bionics Research Center, Korea Institute of Science and Technology, Seoul, South Korea
- Division of Bio-Medical Science and Technology, KIST School, Korea University of Science and Technology, Seoul, South Korea
- *Correspondence: Hyungmin Kim,
| |
Collapse
|
37
|
Arsiwala TA, Sprowls SA, Blethen KE, Fladeland RA, Wolford CP, Kielkowski BN, Glass MJ, Wang P, Wilson O, Carpenter JS, Ranjan M, Finomore V, Rezai A, Lockman PR. Characterization of passive permeability after low intensity focused ultrasound mediated blood-brain barrier disruption in a preclinical model. Fluids Barriers CNS 2022; 19:72. [PMID: 36076213 PMCID: PMC9461249 DOI: 10.1186/s12987-022-00369-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2022] [Accepted: 08/29/2022] [Indexed: 11/15/2022] Open
Abstract
BACKGROUND Systemic drug delivery to the central nervous system is limited by presence of the blood-brain barrier (BBB). Low intensity focused ultrasound (LiFUS) is a non-invasive technique to disrupt the BBB, though there is a lack of understanding of the relationship between LiFUS parameters, such as cavitation dose, time of sonication, microbubble dose, and the time course and magnitude of BBB disruption. Discrepancies in these data arise from experimentation with modified, clinically untranslatable transducers and inconsistent parameters for sonication. In this report, we characterize microbubble and cavitation doses as LiFUS variables as they pertain to the time course and size of BBB opening with a clinical Insightec FUS system. METHODS Female Nu/Nu athymic mice were exposed to LiFUS using the ExAblate Neuro system (v7.4, Insightec, Haifa, Israel) following target verification with magnetic resonance imaging (MRI). Microbubble and cavitation doses ranged from 4-400 μL/kg, and 0.1-1.5 cavitation dose, respectively. The time course and magnitude of BBB opening was evaluated using fluorescent tracers, ranging in size from 105-10,000 Da, administered intravenously at different times pre- or post-LiFUS. Quantitative autoradiography and fluorescence microscopy were used to quantify tracer accumulation in brain. RESULTS We observed a microbubble and cavitation dose dependent increase in tracer uptake within brain after LiFUS. Tracer accumulation was size dependent, with 14C-AIB (100 Da) accumulating to a greater degree than larger markers (~ 625 Da-10 kDa). Our data suggest opening of the BBB via LiFUS is time dependent and biphasic. Accumulation of solutes was highest when administered prior to LiFUS mediated disruption (2-fivefold increases), but was also significantly elevated at 6 h post treatment for both 14C-AIB and Texas Red. CONCLUSION The magnitude of LiFUS mediated BBB opening correlates with concentration of microbubbles, cavitation dose as well as time of tracer administration post-sonication. These data help define the window of maximal BBB opening and applicable sonication parameters on a clinically translatable and commercially available FUS system that can be used to improve passive permeability and accumulation of therapeutics targeting the brain.
Collapse
Affiliation(s)
- Tasneem A. Arsiwala
- grid.268154.c0000 0001 2156 6140Department of Pharmaceutical Sciences, School of Pharmacy, West Virginia University, HSC, Morgantown, 1 Medical Center Dr, Morgantown, WV 26506 USA
| | - Samuel A. Sprowls
- grid.268154.c0000 0001 2156 6140Department of Pharmaceutical Sciences, School of Pharmacy, West Virginia University, HSC, Morgantown, 1 Medical Center Dr, Morgantown, WV 26506 USA ,grid.239578.20000 0001 0675 4725Department of Cardiovascular and Metabolic Sciences, Lerner Research Institute, Cleveland Clinic, Cleveland, OH 44106 USA
| | - Kathryn E. Blethen
- grid.268154.c0000 0001 2156 6140Department of Pharmaceutical Sciences, School of Pharmacy, West Virginia University, HSC, Morgantown, 1 Medical Center Dr, Morgantown, WV 26506 USA
| | - Ross A. Fladeland
- grid.268154.c0000 0001 2156 6140Department of Pharmaceutical Sciences, School of Pharmacy, West Virginia University, HSC, Morgantown, 1 Medical Center Dr, Morgantown, WV 26506 USA
| | - Cullen P. Wolford
- grid.268154.c0000 0001 2156 6140Department of Pharmaceutical Sciences, School of Pharmacy, West Virginia University, HSC, Morgantown, 1 Medical Center Dr, Morgantown, WV 26506 USA
| | - Brooke N. Kielkowski
- grid.268154.c0000 0001 2156 6140Department of Pharmaceutical Sciences, School of Pharmacy, West Virginia University, HSC, Morgantown, 1 Medical Center Dr, Morgantown, WV 26506 USA
| | - Morgan J. Glass
- grid.268154.c0000 0001 2156 6140Department of Pharmaceutical Sciences, School of Pharmacy, West Virginia University, HSC, Morgantown, 1 Medical Center Dr, Morgantown, WV 26506 USA
| | - Peng Wang
- grid.268154.c0000 0001 2156 6140Rockefeller Neuroscience Institute, West Virginia University, 1 Medical Center Dr, Morgantown, WV 26505 USA
| | - Olivia Wilson
- grid.268154.c0000 0001 2156 6140Rockefeller Neuroscience Institute, West Virginia University, 1 Medical Center Dr, Morgantown, WV 26505 USA
| | - Jeffrey S. Carpenter
- grid.268154.c0000 0001 2156 6140Rockefeller Neuroscience Institute, West Virginia University, 1 Medical Center Dr, Morgantown, WV 26505 USA ,grid.268154.c0000 0001 2156 6140Departments of Neuroscience, Neuroradiology, and Neurosurgery, West Virginia University, 1 Medical Center Dr, Morgantown, WV 26505 USA
| | - Manish Ranjan
- grid.268154.c0000 0001 2156 6140Rockefeller Neuroscience Institute, West Virginia University, 1 Medical Center Dr, Morgantown, WV 26505 USA ,grid.268154.c0000 0001 2156 6140Departments of Neuroscience, Neuroradiology, and Neurosurgery, West Virginia University, 1 Medical Center Dr, Morgantown, WV 26505 USA
| | - Victor Finomore
- grid.268154.c0000 0001 2156 6140Departments of Neuroscience, Neuroradiology, and Neurosurgery, West Virginia University, 1 Medical Center Dr, Morgantown, WV 26505 USA
| | - Ali Rezai
- grid.268154.c0000 0001 2156 6140Rockefeller Neuroscience Institute, West Virginia University, 1 Medical Center Dr, Morgantown, WV 26505 USA ,grid.268154.c0000 0001 2156 6140Departments of Neuroscience, Neuroradiology, and Neurosurgery, West Virginia University, 1 Medical Center Dr, Morgantown, WV 26505 USA
| | - Paul R. Lockman
- grid.268154.c0000 0001 2156 6140Department of Pharmaceutical Sciences, School of Pharmacy, West Virginia University, HSC, Morgantown, 1 Medical Center Dr, Morgantown, WV 26506 USA ,grid.268154.c0000 0001 2156 6140Departments of Neuroscience, Neuroradiology, and Neurosurgery, West Virginia University, 1 Medical Center Dr, Morgantown, WV 26505 USA
| |
Collapse
|
38
|
Badadhe JD, Roh H, Lee BC, Kim JH, Im M. Ultrasound stimulation for non-invasive visual prostheses. Front Cell Neurosci 2022; 16:971148. [PMID: 35990889 PMCID: PMC9382087 DOI: 10.3389/fncel.2022.971148] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Accepted: 07/18/2022] [Indexed: 12/04/2022] Open
Abstract
Globally, it is estimated there are more than 2.2 billion visually impaired people. Visual diseases such as retinitis pigmentosa, age-related macular degeneration, glaucoma, and optic neuritis can cause irreversible profound vision loss. Many groups have investigated different approaches such as microelectronic prostheses, optogenetics, stem cell therapy, and gene therapy to restore vision. However, these methods have some limitations such as invasive implantation surgery and unknown long-term risk of genetic manipulation. In addition to the safety of ultrasound as a medical imaging modality, ultrasound stimulation can be a viable non-invasive alternative approach for the sight restoration because of its ability to non-invasively control neuronal activities. Indeed, recent studies have demonstrated ultrasound stimulation can successfully modulate retinal/brain neuronal activities without causing any damage to the nerve cells. Superior penetration depth and high spatial resolution of focused ultrasound can open a new avenue in neuromodulation researches. This review summarizes the latest research results about neural responses to ultrasound stimulation. Also, this work provides an overview of technical viewpoints in the future design of a miniaturized ultrasound transducer for a non-invasive acoustic visual prosthesis for non-surgical and painless restoration of vision.
Collapse
Affiliation(s)
- Jaya Dilip Badadhe
- Brain Science Institute, Korea Institute of Science and Technology (KIST), Seoul, South Korea
- Division of Bio-Medical Science & Technology, KIST School, University of Science and Technology (UST), Seoul, South Korea
| | - Hyeonhee Roh
- Brain Science Institute, Korea Institute of Science and Technology (KIST), Seoul, South Korea
- School of Electrical Engineering, College of Engineering, Korea University, Seoul, South Korea
| | - Byung Chul Lee
- Brain Science Institute, Korea Institute of Science and Technology (KIST), Seoul, South Korea
- Division of Bio-Medical Science & Technology, KIST School, University of Science and Technology (UST), Seoul, South Korea
- KHU-KIST Department of Converging Science and Technology, Kyung Hee University, Seoul, South Korea
| | - Jae Hun Kim
- Sensor System Research Center, Korea Institute of Science and Technology (KIST), Seoul, South Korea
| | - Maesoon Im
- Brain Science Institute, Korea Institute of Science and Technology (KIST), Seoul, South Korea
- Division of Bio-Medical Science & Technology, KIST School, University of Science and Technology (UST), Seoul, South Korea
| |
Collapse
|
39
|
Hu Z, Yang Y, Xu L, Jing Y, Chen H. Airy Beam-enabled Binary Acoustic Metasurfaces for Underwater Ultrasound Beam Manipulation. PHYSICAL REVIEW APPLIED 2022; 18:024070. [PMID: 36600893 PMCID: PMC9809203 DOI: 10.1103/physrevapplied.18.024070] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Airy beams are peculiar beams that are non-diffracting, self-accelerating, and self-healing, and they have offered great opportunities for ultrasound beam manipulation. However, one critical barrier that limits the broad applications of Airy beams in ultrasound is the lack of simply built device to generate Airy beams in water. This work presents a family of Airy beam-enabled binary acoustic metasurfaces (AB-BAMs) to generate Airy beams for underwater ultrasound beam manipulation. AB-BAMs are designed and fabricated by 3D printing with two coding bits: a polylactic acid (which is the commonly used 3D printing material) unit acting as a bit "1" and a water unit acting as a bit "0". The distribution of the binary units on the metasurface is determined by the pattern of Airy beam. To showcase the wavefront engineering capability of the AB-BAMs, several examples of AB-BAMs are designed, 3D printed, and coupled with a planar single-element ultrasound transducer for experimental validation. We demonstrate the capability of AB-BAMs in flexibly tuning the focal region size and beam focusing in 3D space by changing the design of the AB-BAMs. The focal depth of AB-BAMs can be continuous and electronical tuned by adjusting the operating frequency of the planar transducer without replacing the AB-BAMs. The superimposing method is leveraged to enable the generation of complex acoustic fields, e.g., multi-foci and letter patterns (e.g., "W" and "U"). The more complex focal patterns are shown to be also continuously steerable by simply adjusting the operating frequency. Furthermore, the proposed 3D-printed AB-BAMs are simple to design, easy to fabricate, and low-cost to produce with the capabilities to achieve tunable focal size, flexible 3D beam focusing, arbitrary multipoint focusing, and continuous steerability, which creates unprecedented potential for ultrasound beam manipulation.
Collapse
Affiliation(s)
- Zhongtao Hu
- Department of Biomedical Engineering, Washington University in St. Louis, Saint Louis, MO 63130, USA
| | - Yaoheng Yang
- Department of Biomedical Engineering, Washington University in St. Louis, Saint Louis, MO 63130, USA
| | - Lu Xu
- Department of Biomedical Engineering, Washington University in St. Louis, Saint Louis, MO 63130, USA
| | - Yun Jing
- Graduate Program in Acoustics, The Pennsylvania State University, University Park, Pennsylvania 16802, USA
| | - Hong Chen
- Department of Biomedical Engineering, Washington University in St. Louis, Saint Louis, MO 63130, USA
- Department of Radiation Oncology, Washington University School of Medicine, Saint Louis, MO 63108, USA
| |
Collapse
|
40
|
Park TY, Kim HJ, Park SH, Chang WS, Kim H, Yoon K. Differential evolution method to find optimal location of a single-element transducer for transcranial focused ultrasound therapy. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2022; 219:106777. [PMID: 35397411 DOI: 10.1016/j.cmpb.2022.106777] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Revised: 03/14/2022] [Accepted: 03/24/2022] [Indexed: 06/14/2023]
Abstract
BACKGROUND AND OBJECTIVE Focused ultrasound (FUS) has been receiving growing attention as a noninvasive brain stimulation tool because of its superior spatial specificity and depth penetrability. However, the large mismatch of acoustic properties between the skull and water can disrupt and shift the acoustic focus in the brain. In this paper, we present a numerical method to find the optimal location of a single-element FUS transducer, which creates focus on the target region. METHODS The score function, representing the superposition of acoustic waves according to the relative phase difference and transmissibility, was defined based on time-reversal invariance of acoustic waves and depending on the spatial location of the transducer. The optimal location of the transducer was then determined using a differential evolution algorithm. To assess the proposed method, we conducted a forward simulation and compared the resulting focal location to the desired target point. We also performed experimental validation by measuring the acoustic pressure field through an ex vivo human skull in a water tank. RESULTS The numerical results indicated that the score function had a positive proportional relationship with the acoustic pressure at the target. Moreover, for the optimized transducer location, both the numerical and experimental results showed that the normalized acoustic pressure at the target was higher than 0.9. CONCLUSIONS In this study, we developed an optimization method to place a single-element transducer that effectively transmits acoustic energy to the targeted region in the brain. Our numerical and experimental results demonstrate that the proposed method can provide an optimal transducer location for safe and efficient FUS treatment.
Collapse
Affiliation(s)
- Tae Young Park
- Bionics Research Center, Biomedical Research Division, Korea Institute of Science and Technology, Seoul 02792, Republic of Korea; Division of Bio-Medical Science and Technology, KIST School, Korea University of Science and Technology, Seoul 02792, Republic of Korea.
| | - Hyo-Jin Kim
- Center for Healthcare Robotics, Korea Institute of Science and Technology, Seoul 02792, Republic of Korea
| | - So Hui Park
- Department of Neurosurgery, Brain Research Institute, Yonsei University College of Medicine, Seoul 04527, Republic of Korea
| | - Won Seok Chang
- Department of Neurosurgery, Brain Research Institute, Yonsei University College of Medicine, Seoul 04527, Republic of Korea
| | - Hyungmin Kim
- Bionics Research Center, Biomedical Research Division, Korea Institute of Science and Technology, Seoul 02792, Republic of Korea; Division of Bio-Medical Science and Technology, KIST School, Korea University of Science and Technology, Seoul 02792, Republic of Korea.
| | - Kyungho Yoon
- School of Mathematics and Computing (Computational Science and Engineering), Yonsei University, Seoul 03722, Republic of Korea.
| |
Collapse
|
41
|
Sarica C, Nankoo JF, Fomenko A, Grippe TC, Yamamoto K, Samuel N, Milano V, Vetkas A, Darmani G, Cizmeci MN, Lozano AM, Chen R. Human Studies of Transcranial Ultrasound neuromodulation: A systematic review of effectiveness and safety. Brain Stimul 2022; 15:737-746. [DOI: 10.1016/j.brs.2022.05.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2022] [Revised: 04/25/2022] [Accepted: 05/02/2022] [Indexed: 01/11/2023] Open
|
42
|
Xie P, Hao Y, Chen X, Jin Z, Cheng S, Li X, Liu L, Yuan Y, Li X. Enhancement of functional corticomuscular coupling after transcranial ultrasound stimulation in mice. J Neural Eng 2022; 19. [PMID: 35272276 DOI: 10.1088/1741-2552/ac5c8b] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2021] [Accepted: 03/10/2022] [Indexed: 11/11/2022]
Abstract
OBJECTIVE Transcranial ultrasound stimulation (TUS), a large penetration depth and high spatial resolution technology, has developed rapidly in recent years. This study aimed to explore and evaluate the neuromodulation effects of TUS on mouse motor neural circuits under different parameters. APPROACH Our study used functional corticomuscular coupling (FCMC) as an index to explore the modulation mechanism for movement control under different TUS parameters (intensity [Isppa] and stimulation duration [SD]). We collected local field potential (LFP) and tail electromyographic (EMG) data under TUS in healthy mice and then introduced the time-frequency coherence method to analyze the FCMC before and after TUS in the time-frequency domain. After that, we defined the relative coherence area (RCA) to quantify the coherence between LFP and EMG under TUS. MAIN RESULTS The FCMC at theta, alpha, beta, and gamma bands was enhanced after TUS, and the neuromodulation efficacy mainly occurred in the lower frequency band (theta and alpha band). After TUS with different parameters, the FCMC in all selected frequency bands showed a tendency of increasing first and then decreasing. Further analysis showed that the maximum coupling value of theta band appeared from 0.2 to 0.4 s, and that the maximum coupling value in alpha and gamma band appeared from 0 to 0.2 s. SIGNIFICANCE The aforementioned results demonstrate that FCMC in the motor cortex could be modulated by TUS. We provide a theoretical basis for further exploring the modulation mechanism of TUS parameters and clinical application.
Collapse
Affiliation(s)
- Ping Xie
- Yanshan University, Yanshan University, Qinhuangdao, Hebei, China, Qinhuangdao, 066004, CHINA
| | - Yingying Hao
- Yanshan University School of Electrical Engineering, Yanshan University, Qinhuangdao, Hebei, China, Qinhuangdao, Hebei, 066004, CHINA
| | - Xiaoling Chen
- Yanshan University, Yanshan University, Qinhuangdao, Hebei, China, Qinhuangdao, 066004, CHINA
| | - Ziqiang Jin
- Yanshan University, Yanshan University, Qinhuangdao, Hebei, China, Qinhuangdao, Hebei, 066004, CHINA
| | - Shengcui Cheng
- Yanshan University, Yanshan University, Qinhuangdao, Hebei, China, Qinhuangdao, Hebei, 066004, CHINA
| | - Xin Li
- Yanshan University, Yanshan University, Qinhuangdao, Hebei, China, Qinhuangdao, 066004, CHINA
| | - Lanxiang Liu
- People's Hospital, Qinhuangdao, People's Hospital, Qinhuangdao, Hebei, China, Qinhuangdao, 066004, CHINA
| | - Yi Yuan
- Yanshan University School of Electrical Engineering, Yanshan University, Qinhuangdao, Hebei, China, Qinhuangdao, Hebei, 066004, CHINA
| | - Xiaoli Li
- Beijing Normal University, Beijing Normal University, Beijing, China, Beijing, 100000, CHINA
| |
Collapse
|
43
|
Kang KC, Kim YH, Kim JN, Kabir M, Zhang Y, Ghanouni P, Park KK, Firouzi K, Khuri-Yakub BT. Increasing the transmission efficiency of transcranial ultrasound using a dual-mode conversion technique based on Lamb waves. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2022; 151:2159. [PMID: 35364946 PMCID: PMC8957390 DOI: 10.1121/10.0009849] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/14/2021] [Revised: 02/24/2022] [Accepted: 03/05/2022] [Indexed: 06/14/2023]
Abstract
Transcranial focused ultrasound (FUS) is a noninvasive treatment for brain tumors and neuromodulation. Based on normal incidence, conventional FUS techniques use a focused or an array of ultrasonic transducers to overcome the attenuation and absorption of ultrasound in the skull; however, this remains the main limitation of using FUS. A dual-mode conversion technique based on Lamb waves is proposed to achieve high transmission efficiency. This concept was validated using the finite element analysis (FEA) and experiments based on changes in the incident angle. Aluminum, plexiglass, and a human skull were used as materials with different attenuations. The transmission loss was calculated for each material, and the results were compared with the reflectance function of the Lamb waves. Oblique incidence based on dual-mode conversion exhibited a better transmission efficiency than that of a normal incidence for all of the specimens. The total transmission losses for the materials were 13.7, 15.46, and 3.91 dB less than those associated with the normal incidence. A wedge transducer was designed and fabricated to implement the proposed method. The results demonstrated the potential applicability of the dual-mode conversion technique for the human skull.
Collapse
Affiliation(s)
- Ki Chang Kang
- Mechanical Convergence Engineering, Hanyang University, Seoul, Republic of Korea
| | - Young Hun Kim
- Mechanical Convergence Engineering, Hanyang University, Seoul, Republic of Korea
| | - Jeong Nyeon Kim
- E. L. Ginzton Laboratory, Department of Electrical Engineering, Stanford University, Stanford, California 94305, USA
| | - Minoo Kabir
- E. L. Ginzton Laboratory, Department of Electrical Engineering, Stanford University, Stanford, California 94305, USA
| | - Yichi Zhang
- E. L. Ginzton Laboratory, Department of Electrical Engineering, Stanford University, Stanford, California 94305, USA
| | - Pejman Ghanouni
- Department of Radiology, Stanford University, Stanford, California 94305, USA
| | - Kwan Kyu Park
- Mechanical Convergence Engineering, Hanyang University, Seoul, Republic of Korea
| | - Kamyar Firouzi
- E. L. Ginzton Laboratory, Department of Electrical Engineering, Stanford University, Stanford, California 94305, USA
| | - Burtus T Khuri-Yakub
- E. L. Ginzton Laboratory, Department of Electrical Engineering, Stanford University, Stanford, California 94305, USA
| |
Collapse
|
44
|
Kim YH, Kang KC, Kim JN, Pai CN, Zhang Y, Ghanouni P, Park KK, Firouzi K, Khuri-Yakub BT. Patterned Interference Radiation Force for Transcranial Neuromodulation. ULTRASOUND IN MEDICINE & BIOLOGY 2022; 48:497-511. [PMID: 34955292 DOI: 10.1016/j.ultrasmedbio.2021.11.006] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/27/2021] [Revised: 11/06/2021] [Accepted: 11/10/2021] [Indexed: 06/14/2023]
Abstract
Compared with the conventional method of transcranial focused ultrasound stimulation using a single transducer or a focused beam, the compression and tensile forces are generated from the high-pressure gradient of a standing wave that can generate increased stimulation. We experimentally verified a neuromodulation system using patterned interference radiation force (PIRF) and propose a method for obtaining the magnitude of the radiation force, which is considered the main factor influencing ultrasound neuromodulation. The radiation forces generated using a single focused transducer and a standing wave created via two focused transducers were compared using simulations. Radiation force was calculated based on the relationship between the acoustic pressure, radiation force and time-averaged second-order pressure obtained using an acoustic streaming simulation. The presence of the radiation force was verified by measuring the time-averaged second-order pressure generated due to the radiation force, by using a glass tube.
Collapse
Affiliation(s)
- Young Hun Kim
- E. L. Ginzton Laboratory, Department of Electrical Engineering, Stanford University, Stanford, California, USA; Mechanical Convergence Engineering, Hanyang University, Seoul, Republic of Korea
| | - Ki Chang Kang
- E. L. Ginzton Laboratory, Department of Electrical Engineering, Stanford University, Stanford, California, USA; Mechanical Convergence Engineering, Hanyang University, Seoul, Republic of Korea
| | - Jeong Nyeon Kim
- E. L. Ginzton Laboratory, Department of Electrical Engineering, Stanford University, Stanford, California, USA
| | - Chi Nan Pai
- E. L. Ginzton Laboratory, Department of Electrical Engineering, Stanford University, Stanford, California, USA; Department of Mechatronics Engineering, Polytechnic School of the University of Sao Paulo, Sao Paulo, Brazil
| | - Yichi Zhang
- E. L. Ginzton Laboratory, Department of Electrical Engineering, Stanford University, Stanford, California, USA
| | - Pejman Ghanouni
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Kwan Kyu Park
- E. L. Ginzton Laboratory, Department of Electrical Engineering, Stanford University, Stanford, California, USA; Mechanical Convergence Engineering, Hanyang University, Seoul, Republic of Korea.
| | - Kamyar Firouzi
- E. L. Ginzton Laboratory, Department of Electrical Engineering, Stanford University, Stanford, California, USA
| | - Burtus T Khuri-Yakub
- E. L. Ginzton Laboratory, Department of Electrical Engineering, Stanford University, Stanford, California, USA
| |
Collapse
|
45
|
Seo H, Huh H, Lee EH, Park J. Numerical Evaluation of the Effects of Transducer Displacement on Transcranial Focused Ultrasound in the Rat Brain. Brain Sci 2022; 12:216. [PMID: 35203979 PMCID: PMC8870101 DOI: 10.3390/brainsci12020216] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Revised: 01/15/2022] [Accepted: 02/03/2022] [Indexed: 02/04/2023] Open
Abstract
Focused ultrasound is a promising therapeutic technique, as it involves the focusing of an ultrasonic beam with sufficient acoustic energy into a target brain region with high precision. Low-intensity ultrasound transmission by a single-element transducer is mostly established for neuromodulation applications and blood-brain barrier disruption for drug delivery. However, transducer positioning errors can occur without fine control over the sonication, which can affect repeatability and lead to reliability problems. The objective of this study was to determine whether the target brain region would be stable under small displacement (0.5 mm) of the transducer based on numerical simulations. Computed-tomography-derived three-dimensional models of a rat head were constructed to investigate the effects of transducer displacement in the caudate putamen (CP) and thalamus (TH). Using three different frequencies (1.1, 0.69, and 0.25 MHz), the transducer was displaced by 0.5 mm in each of the following six directions: superior, interior, anterior, posterior, left, and right. The maximum value of the intracranial pressure field was calculated, and the targeting errors were determined by the full-width-at-half-maximum (FWHM) overlap between the free water space (FWHMwater) and transcranial transmission (FWHMbase). When the transducer was positioned directly above the target region, a clear distinction between the target regions was observed, resulting in 88.3%, 81.5%, and 84.5% FWHMwater for the CP and 65.6%, 76.3%, and 64.4% FWHMwater for the TH at 1.1, 0.69, and 0.25 MHz, respectively. Small transducer displacements induced both enhancement and reduction of the peak pressure and targeting errors, compared with when the transducer was displaced in water. Small transducer displacement to the left resulted in the lowest stability, with 34.8% and 55.0% targeting accuracy (FWHMwater) at 1.1 and 0.69 MHz in the TH, respectively. In addition, the maximum pressure was reduced by up to 11% by the transducer displacement. This work provides the targeting errors induced by transducer displacements through a preclinical study and recommends that attention be paid to determining the initial sonication foci in the transverse plane in the cases of small animals.
Collapse
Affiliation(s)
- Hyeon Seo
- Medical Device Development Center, Daegu-Gyeongbuk Medical Innovation Foundation, Daegu 41061, Korea; (H.S.); (H.H.); (E.-H.L.)
| | - Hyungkyu Huh
- Medical Device Development Center, Daegu-Gyeongbuk Medical Innovation Foundation, Daegu 41061, Korea; (H.S.); (H.H.); (E.-H.L.)
| | - Eun-Hee Lee
- Medical Device Development Center, Daegu-Gyeongbuk Medical Innovation Foundation, Daegu 41061, Korea; (H.S.); (H.H.); (E.-H.L.)
| | - Juyoung Park
- Medical Device Development Center, Daegu-Gyeongbuk Medical Innovation Foundation, Daegu 41061, Korea; (H.S.); (H.H.); (E.-H.L.)
- Department of High-Tech Medical Device, College of Future Industry, Gachon University, Seongnam-si 13120, Korea
| |
Collapse
|
46
|
Cheng Z, Wang C, Wei B, Gan W, Zhou Q, Cui M. High resolution ultrasonic neural modulation observed via in vivo two-photon calcium imaging. Brain Stimul 2022; 15:190-196. [PMID: 34952226 PMCID: PMC9169577 DOI: 10.1016/j.brs.2021.12.005] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2021] [Revised: 12/16/2021] [Accepted: 12/17/2021] [Indexed: 02/09/2023] Open
Abstract
Neural modulation plays a major role in delineating the circuit mechanisms and serves as the cornerstone of neural interface technologies. Among the various modulation mechanisms, ultrasound enables noninvasive label-free deep access to mammalian brain tissue. To date, most if not all ultrasonic neural modulation implementations are based on ∼1 MHz carrier frequency. The long acoustic wavelength results in a spatially coarse modulation zone, often spanning over multiple function regions. The modulation of one function region is inevitably linked with the modulation of its neighboring regions. Moreover, the lack of in vivo cellular resolution cell-type-specific recording capabilities in most studies prevents the revealing of the genuine cellular response to ultrasound. To significantly increase the spatial resolution, we explored the application of high-frequency ultrasound. To investigate the neuronal response at cellular resolutions, we developed a dual-modality system combining in vivo two-photon calcium imaging and focused ultrasound modulation. The studies show that the ∼30 MHz ultrasound can suppress the neuronal activity in awake mice at 100-μm scale spatial resolutions, paving the way for high-resolution ultrasonic neural modulation. The dual-modality in vivo system validated through this study will serve as a general platform for studying the dynamics of various cell types in response to ultrasound.
Collapse
Affiliation(s)
- Zongyue Cheng
- School of Electrical and Computer Engineering, Purdue University, West Lafayette, IN, 47907, USA; Bindley Bioscience Center, Purdue University, West Lafayette, IN, 47907, USA
| | - Chenmao Wang
- School of Electrical and Computer Engineering, Purdue University, West Lafayette, IN, 47907, USA; Bindley Bioscience Center, Purdue University, West Lafayette, IN, 47907, USA
| | - Bowen Wei
- School of Electrical and Computer Engineering, Purdue University, West Lafayette, IN, 47907, USA; Bindley Bioscience Center, Purdue University, West Lafayette, IN, 47907, USA
| | - Wenbiao Gan
- Skirball Institute, Department of Neuroscience and Physiology, Department of Anesthesiology, New York University School of Medicine, New York, NY, 10016, USA
| | - Qifa Zhou
- Department of Biomedical Engineering and Department of Ophthalmology, University of Southern California, Los Angeles, CA, 90089, USA
| | - Meng Cui
- School of Electrical and Computer Engineering, Purdue University, West Lafayette, IN, 47907, USA; Bindley Bioscience Center, Purdue University, West Lafayette, IN, 47907, USA; Department of Biology, Purdue University, West Lafayette, IN, 47907, USA.
| |
Collapse
|
47
|
Ultra-high-field MRI studies of brain structure and function in humans and nonhuman primates: A collaborative approach to precision medicine. CURRENT OPINION IN BIOMEDICAL ENGINEERING 2021. [DOI: 10.1016/j.cobme.2021.100320] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
48
|
Lee SM, Lee T, Kim H, Jo Y, Kim MG, Kim S, Bae HM, Lee HJ. Calcium-Modified Silk Patch as a Next-Generation Ultrasound Coupling Medium. ACS APPLIED MATERIALS & INTERFACES 2021; 13:55827-55839. [PMID: 34784167 DOI: 10.1021/acsami.1c16735] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
There is an increasing interest in developing next-generation wearable ultrasound patch systems because of their wide range of applications, such as home healthcare systems and continuous monitoring systems for physiological conditions. A wearable ultrasound patch system requires a stable interface to the skin, an ultrasound coupling medium, a flexible transducer array, and miniaturized operating circuitries. In this study, we proposed a patch composed of calcium (Ca)-modified silk, which serves as both a stable interface and a coupling medium for ultrasound transducer arrays. The Ca-modified silk patch provided not only a stable and conformal interface between the epidermal ultrasound transducer and human skin with high adhesion but also offered acoustic impedance close to that of human skin. The Ca-modified silk patch was flexible and stretchable (∼400% strain) and could be attached to various materials. In addition, because the acoustic impedance of the Ca-modified silk patch was 2.15 MRayl, which was similar to that of human skin (1.99 MRayl), the ultrasound transmission loss of the proposed patch was relatively low (∼0.002 dB). We also verified the use of the Ca-modified silk patch in various ultrasound applications, including ultrasound imaging, ultrasound heating, and transcranial ultrasound stimulation for neuromodulation. The comparable performance of the Ca-modified patch to that of a commercial ultrasound gel and its durability against various environmental conditions confirmed that the Ca-modified silk patch could be a promising candidate as a coupling medium for next-generation ultrasound patch systems.
Collapse
Affiliation(s)
- Sang-Mok Lee
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea
| | - Taemin Lee
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea
| | - Hyojung Kim
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea
| | - Yehhyun Jo
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea
| | - Myeong-Gee Kim
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea
| | - Subeen Kim
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea
| | - Hyeon-Min Bae
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea
| | - Hyunjoo J Lee
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea
- KAIST Institute for Health Science and Technology (KIHST), Daejeon 34141, Republic of Korea
- KAIST Institute for NanoCentury (KINC), Daejeon 34141, Republic of Korea
| |
Collapse
|