1
|
Melas A, Trikka M, Valentini S, Cotogno G, Giechaskiel B. Calibrations, Validations, and Checks of a Dual 23 nm and 10 nm Diffusion Charger-Based Portable Emissions Measurement System (PEMS). NANOMATERIALS (BASEL, SWITZERLAND) 2024; 14:1258. [PMID: 39120363 PMCID: PMC11314171 DOI: 10.3390/nano14151258] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/05/2024] [Revised: 07/24/2024] [Accepted: 07/25/2024] [Indexed: 08/10/2024]
Abstract
The upcoming Euro 7 vehicle exhaust emissions regulation includes particle number (PN) limits for all vehicles, not only those with direct fuel injection. It also sets the lower detection particle size of the PN methodology to 10 nm from 23 nm. Recently, a commercial diffusion charger-based PEMS added the possibility of switching the lower size between 23 nm and 10 nm. In this study, we assessed the dual PEMS in the calibration laboratory using diffusion flame soot or spark discharge graphite particles following the regulated procedures. Furthermore, we compared the dual PEMS with a laboratory grade system (LABS) using soot, graphite, and vehicle exhaust particles. To put the results into perspective, we added comparisons (validations) of two additional 23 nm PEMSs with LABSs over a three-year period. The results showed that the differences of the 23 nm PEMSs remained the same (around 35% underestimation) over the years and were similar to the dual PEMS. This difference is still well within the permissible tolerance from the regulation (50%). We argued that the reason is the calibration material used by the manufacturer (spark discharge graphite). We demonstrated that calibrating with combustion soot could reduce the differences. The 10 nm PEMS gave similar results but with much smaller differences, indicating that the calibration material is of less importance for the Euro 7 step. The results showed that the measurement uncertainty has not increased but rather decreased for the specific PEMS switching from 23 nm to 10 nm.
Collapse
Affiliation(s)
| | | | | | | | - Barouch Giechaskiel
- Joint Research Centre (JRC), European Commission, 21027 Ispra, Italy; (A.M.); (M.T.); (S.V.); (G.C.)
| |
Collapse
|
2
|
McLean P, Hanlon J, Salmatonidis A, Galea KS, Brooker F, Citterio C, Magni D, Vázquez-Campos S, Lotti D, Boyles MSP. Safe(r)-by-design principles in the thermoplastics industry: guidance on release assessment during manufacture of nano-enabled products. Front Public Health 2024; 12:1398104. [PMID: 39035186 PMCID: PMC11257848 DOI: 10.3389/fpubh.2024.1398104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2024] [Accepted: 06/18/2024] [Indexed: 07/23/2024] Open
Abstract
Background The application of nanomaterials (NMs) and nano-enabled products (NEPs) across many industries has been extensive and is still expanding decades after first being identified as an emerging technology. Additive manufacturing has been greatly impacted and has seen the benefits of integrating NMs within products. With the expansion of nanotechnology, there has been a need to develop more adaptive and responsive methods to ascertain risks and ensure technology is developed safely. The Safe(r)-by-Design (SbD) concept can be used to establish safe parameters and minimise risks during the materials' lifecycle, including the early stages of the supply chain. Exposure monitoring has advanced in recent years with the creation of standardised protocols for occupational exposure assessment of nano-objects and their aggregates and agglomerates (NOAA). Methods To aid in the development of an online SbD-supporting platform by the EU-funded project SAbyNA, we adopt a Europe Standard for monitoring release of NOAA to identify if a greater release of NOAA is associated with incorporation of NMs within NEPs compared to a polymer matrix alone. Case studies included filaments of polypropylene (PP) with nano-Ag or polycarbonate (PC) with single-walled carbon nanotubes (SWCNTs). NMs were received in masterbatch, and therefore previously modified to align with SbD interventions. Results were collected in line with European Standard recommendations: monitoring particle concentrations using direct reading instruments (DRI), sampling for offline chemical and morphological analysis, and collecting contextual information. Results and discussion Based on the criteria described in the European standard (BS EN 17058), data from both case studies identified that inhalation exposure relating to NM was "unlikely". Despite this, during the production of the SWCNT-PC filaments, some noteworthy observations were made, including several DRI activity measurements shown to be higher than background levels, and material morphologically similar to the reference SWCNT/polymeric masterbatch observed in offline analysis. The data collected during this campaign were used to discuss choices available for data interpretation and decision-making in the European Standard for monitoring release of NOAA and also to facilitate the development of SAbyNA's user-friendly industry platform for the SbD of NMs and NEPs.
Collapse
Affiliation(s)
- Polly McLean
- Institute of Occupational Medicine, Edinburgh, United Kingdom
| | - James Hanlon
- Institute of Occupational Medicine, Edinburgh, United Kingdom
- Ricardo, Glasgow, United Kingdom
| | | | - Karen S. Galea
- Institute of Occupational Medicine, Edinburgh, United Kingdom
| | - Finlay Brooker
- Institute of Occupational Medicine, Edinburgh, United Kingdom
| | | | - Daniele Magni
- LATI Industria Termoplastici S.p.A., Vedano Olona, Italy
| | | | - Davide Lotti
- LATI Industria Termoplastici S.p.A., Vedano Olona, Italy
| | - Matthew S. P. Boyles
- Institute of Occupational Medicine, Edinburgh, United Kingdom
- Centre for Biomedicine and Global Health, School of Applied Sciences, Edinburgh Napier University, Edinburgh, United Kingdom
| |
Collapse
|
3
|
Guan S, Tang M. Exposure of quantum dots in the nervous system: Central nervous system risks and the blood-brain barrier interface. J Appl Toxicol 2024; 44:936-952. [PMID: 38062852 DOI: 10.1002/jat.4568] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2023] [Revised: 11/16/2023] [Accepted: 11/16/2023] [Indexed: 07/21/2024]
Abstract
Quantum dots currently possess significant importance in the field of biomedical science. Upon introduction into the body, quantum dots exhibit a tendency to accumulate in diverse tissues including the central nervous system (CNS). Consequently, it becomes imperative to devote specific attention to their potential toxic effects. Moreover, the preservation of optimal CNS function relies heavily on blood-brain barrier (BBB) integrity, thereby necessitating its prioritization in neurotoxicological investigations. A more comprehensive understanding of the BBB and CNS characteristics, along with the underlying mechanisms that may contribute to neurotoxicity, will greatly aid researchers in the development of effective design strategies. This article offers an in-depth look at the methods used to reduce the harmful effects of quantum dots on the nervous system, alongside the progression of effective treatments for brain-related conditions. The focal point of this discussion is the BBB and its intricate association with the CNS and neurotoxicology. The discourse commences by recent advancements in the medical application of quantum dots are examined. Subsequently, elucidating the mechanisms through which quantum dots infiltrate the human body and traverse into the brain. Additionally, the discourse delves into the factors that facilitate the passage of quantum dots across the BBB, primarily encompassing the physicochemical properties of quantum dots and the BBB's inherent capacity for self-permeability alteration. Furthermore, a concluding summary is presented, emphasizing existing research deficiencies and identifying promising avenues for further investigation within this field.
Collapse
Affiliation(s)
- Shujing Guan
- Key Laboratory of Environmental Medicine and Engineering, Ministry of Education, School of Public Health, Southeast University, Nanjing, China
| | - Meng Tang
- Key Laboratory of Environmental Medicine and Engineering, Ministry of Education, School of Public Health, Southeast University, Nanjing, China
| |
Collapse
|
4
|
Rizzo M, Bordignon M, Bertoli P, Biasiol G, Crosera M, Magnano GC, Marussi G, Negro C, Larese Filon F. Exposure to gallium arsenide nanoparticles in a research facility: a case study using molecular beam epitaxy. Nanotoxicology 2024; 18:259-271. [PMID: 38647006 DOI: 10.1080/17435390.2024.2341893] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2024] [Accepted: 04/05/2024] [Indexed: 04/25/2024]
Abstract
We evaluated GaAs nanoparticle-concentrations in the air and on skin and surfaces in a research facility that produces thin films, and to monitored As in the urine of exposed worker. The survey was over a working week using a multi-level approach. Airborne personal monitoring was implemented using a miniature diffusion size classifier (DiSCMini) and IOM sampler. Environmental monitoring was conducted using the SKC Sioutas Cascade Impactor to evaluate dimensions and nature of particles collected. Surfaces contamination were assessed analyzing As and Ga in ghost wipes. Skin contamination was monitored using tape strips. As and Ga were analyzed in urines collected every day at the beginning and end of the shift. The greatest airborne exposure occurred during the cutting operations of the GaAs Sample (88883 np/cm3). The highest levels of contamination were found inside the hood (As max = 1418 ng/cm2) and on the laboratory floor (As max = 251 ng/cm2). The average concentration on the worker's skin at the end of the work shift (3.36 ng/cm2) was more than 14 times higher than before the start of the shift. In weekly urinary biomonitoring an average As concentration of 19.5 µg/L, which was above the Società Italiana Valori di Riferimento (SIVR) reference limit for the non-occupational population (2.0 - 15 µg/L), but below the ACGIH limit (30 µg/L). Overall, airborne monitoring, surface sampling, skin sampling, and biomonitoring of worker confirmed the exposure to As of workers. Systematic cleaning operations, hood implementation and correct PPE management are needed to improve worker protection.
Collapse
Affiliation(s)
- Marco Rizzo
- Inter-University Degree Course in Prevention Techniques in the Environment and Workplaces, University of Udine and Trieste, Trieste, Italy
| | - Michele Bordignon
- Inter-University Degree Course in Prevention Techniques in the Environment and Workplaces, University of Udine and Trieste, Trieste, Italy
| | - Paolo Bertoli
- Clinical Operational Unit of Occupational Medicine, University of Trieste, Trieste, Italy
| | | | - Matteo Crosera
- Department of Chemical and Pharmaceutical Sciences, University of Trieste, Trieste, Italy
| | - Greta Camilla Magnano
- Clinical Operational Unit of Occupational Medicine, University of Trieste, Trieste, Italy
| | - Giovanna Marussi
- Department of Chemical and Pharmaceutical Sciences, University of Trieste, Trieste, Italy
| | - Corrado Negro
- Clinical Operational Unit of Occupational Medicine, University of Trieste, Trieste, Italy
| | - Francesca Larese Filon
- Clinical Operational Unit of Occupational Medicine, University of Trieste, Trieste, Italy
| |
Collapse
|
5
|
Belosi F, Koivisto AJ, Furxhi I, de Ipiña JL, Nicosia A, Ravegnani F, Ortelli S, Zanoni I, Costa A. Critical aspects in occupational exposure assessment with different aerosol metrics in an industrial spray coating process. NANOIMPACT 2023; 30:100459. [PMID: 36948454 DOI: 10.1016/j.impact.2023.100459] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Revised: 03/14/2023] [Accepted: 03/15/2023] [Indexed: 06/03/2023]
Abstract
Engineered Nanomaterials (ENMs) have several uses in various industrial fields and are embedded in a myriad of consumer products. However, there is continued concern over the potential adverse health effects and environmental impacts of ENMs due to their unique physico-chemical characteristics. Currently, there are no specific international regulations for various ENMs. There are also no Occupational Exposure Limits (OEL) regulated by the European Union (EU) for nanomaterials in the form of nano-objects, their aggregates or agglomerates (NOAA). For ENMs the question of which metric to be used (i.e., mass, surface area, number concentrations) to determine the exposure is still not resolved. The aim of this work is to assess the worker exposure by inhalation in an industrial spray coating process by using all three metrics mentioned above. Two target ENMs (N-doped TiO2, TiO2N and AgNPs capped with a quaternized hydroxyethyl-cellulose, AgHEC) generated for industrial-scale spraying processes were considered. Results showed that the averaged particle number concentration (10-100 nm) was below 2.7 104 cm-3 for both materials. The Lung Deposited Surface Area (LDSA) was in the range between 73 and 98 μm2cm-3 and the particle mass concentration (obtained by means of ICP-EOS off-line analysis) resulted below 70 μg m-3 and 0.4 μg m-3 for TiO2 and Ag, respectively. Although, the airborne particles concentration compared well with the NIOSH Recommended Exposure Level (REL) limits the contribution to the background, according to EN 17058 (Annex E) was significant (particularly in the particle number and PM1 mass concentrations). We successfully evaluated the worker exposure by means of the different airborne particles' metrics (number, surface and mass concentrations). We concluded that worker exposure assessment involving ENMs is a complex procedure with requires both real time and off-line measurements and a deep investigation of the background.
Collapse
Affiliation(s)
- Franco Belosi
- CNR-ISAC, National Research Council of Italy, Institute of Atmospheric Sciences and Climate, Via Gobetti 101, 40129 Bologna, Italy
| | - Antti Joonas Koivisto
- Air Pollution Management APM, Mattilanmäki 38, 33610 Tampere, Finland; Institute for Atmospheric and Earth System Research (INAR), University of Helsinki, PL 64, FI-00014 UHEL, Helsinki, Finland; ARCHE Consulting, Liefkensstraat 35D, Wondelgem B-9032, Belgium
| | - Irini Furxhi
- Transgero Limited, Cullinagh, Newcastle West, Co. Limerick, Limerick, Ireland; Department of Accounting and Finance, Kemmy Business School, University of Limerick, Limerick V94 T9PX, Ireland
| | - Jesús Lopez de Ipiña
- TECNALIA, Basque Research and Technology Alliance (BRTA), Parque Tecnológico de Alava, Leonardo Da Vinci 11, 01510 Miñano, Spain
| | - Alessia Nicosia
- CNR-ISAC, National Research Council of Italy, Institute of Atmospheric Sciences and Climate, Via Gobetti 101, 40129 Bologna, Italy
| | - Fabrizio Ravegnani
- CNR-ISAC, National Research Council of Italy, Institute of Atmospheric Sciences and Climate, Via Gobetti 101, 40129 Bologna, Italy
| | - Simona Ortelli
- CNR-ISSMC (former ISTEC), National Research Council of Italy, Institute of Science, Technology and Sustainability for Ceramics, Via Granarolo 64, 48018 Faenza, Italy.
| | - Ilaria Zanoni
- CNR-ISSMC (former ISTEC), National Research Council of Italy, Institute of Science, Technology and Sustainability for Ceramics, Via Granarolo 64, 48018 Faenza, Italy
| | - Anna Costa
- CNR-ISSMC (former ISTEC), National Research Council of Italy, Institute of Science, Technology and Sustainability for Ceramics, Via Granarolo 64, 48018 Faenza, Italy
| |
Collapse
|
6
|
López M, López-Lilao A, Romero F, Pérez-Albaladejo E, Pinteño R, Porte C, Balasch A, Eljarrat E, Viana M, Monfort E. Size-resolved chemical composition and toxicity of particles released from refit operations in shipyards. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 880:163072. [PMID: 36990238 DOI: 10.1016/j.scitotenv.2023.163072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Revised: 03/08/2023] [Accepted: 03/22/2023] [Indexed: 04/15/2023]
Abstract
Ship refit and repair operations in shipyards generate aerosol emissions with high potential for environmental impacts. Metal-bearing nano-, fine and coarse particles are incidentally formed and can be released to indoor and ambient air and the aquatic environment. This work aimed to further the understanding of these impacts by characterising particle size-resolved chemical composition (15 nm - 10 μm), organophosphate esters (OPEs) content (e.g., plasticisers) and cytotoxic and genotoxic potential. Results showed that nanoparticle emissions (20-110 nm) took place in bursts, coinciding with the use of mechanical abraders and spray-painting guns. Tracers of these activities were Sc, V, Cr, Co, Ni, Cu, Rb, Nb, and Cs. Key components were V and Cu, probably sourcing from nanoadditives in the coatings. Abrasion of coatings also emitted OPEs, especially from old paints. Toxicity assessments consistently evidenced hazardous potential for the different endpoints assessed, for a number of samples. Exposures to spray-painting aerosols were linked with reduced cell viability (cytotoxicity), significant generation of reactive oxygen species (ROS), and increases in micronuclei frequency (genotoxicity). Even though spray-painting did not contribute significantly to aerosol mass or number concentrations, it was a major driver of potential health effects. Results suggest that aerosol chemical composition (e.g., content in nano-sized Cu or V) may have a larger impact on toxicity than aerosol concentration. While direct human exposures may be prevented using personal and collective protective equipment and environmental release can be minimised by enclosures and filtration systems, impacts on ambient air and the aquatic environment cannot be fully prevented. The continued use of good practices (exhaust, dilution, general ventilation systems, PPE, already in place) is encouraged to reduce inhalation exposures inside the tents. Understanding the size-resolved chemical and toxicological properties of aerosols is key to reducing human health and environmental impacts of ship refit operations in shipyards.
Collapse
|
7
|
Das A, Baig NA, Yawar M, Kumar A, Habib G, Perumal V. Size fraction of hazardous particulate matter governing the respiratory deposition and inhalation risk in the highly polluted city Delhi. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2023; 30:11600-11616. [PMID: 36097310 DOI: 10.1007/s11356-022-22733-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/27/2022] [Accepted: 08/22/2022] [Indexed: 06/15/2023]
Abstract
Delhi has been identified as one of the highly polluted cities in the world and recently associated with the highest population weighted PM2.5 concentration. However, the unavailability of the health risk estimations using long-term data for Indian cities has been pointed out as a hurdle in performing the correct assessment. The present work estimated deposition of particles in different regions of respiratory systems (head airway = 67% deposition for 2.5 µm particles; tracheo-bronchiolar (TB) = 73% deposition for 1.0 µm particles; alveolar (AL) = 17% deposition for 0.5 µm, 0.25 µm, and < 0.25 µm particles) using PM samples collected at a breathing height of 1.5 m near the major ring road in New Delhi (India). The calculated risk index (RI) varied considerably between winter (1.21 ± 0.26 to 1.33 ± 0.50) and pre-monsoon-southwest monsoon months (0.34 ± 0.08 to 0.96 ± 0.27). Respiratory deposition dose of nanosized particles (≤ 500 nm) in the alveoli region of the lung was found to be considerable (35%) indicating the need for understanding the role of these particles in posing health risk. Although the calculated values of risk metric for exposures of PM-associated metals indicated no risk to IIT Delhi population (hazard quotient < 1 and excess risk of getting cancer < 10-6-10-9), continuous monitoring for particles of different sizes at inhalation height are required for protecting human health.
Collapse
Affiliation(s)
- Ananya Das
- Department of Civil Engineering, Indian Institute of Technology, Delhi, India
| | - Nisar Ali Baig
- Department of Civil Engineering, Indian Institute of Technology, Delhi, India
| | - Mohammad Yawar
- Department of Mathematics, University of Houston, Houston, USA
| | - Arun Kumar
- Department of Civil Engineering, Indian Institute of Technology, Delhi, India
| | - Gazala Habib
- Department of Civil Engineering, Indian Institute of Technology, Delhi, India.
| | - Vivekanandan Perumal
- Kusuma School of Biological Sciences, Indian Institute of Technology, Delhi, India
| |
Collapse
|
8
|
Schulte PA, Iavicoli I, Fontana L, Leka S, Dollard MF, Salmen-Navarro A, Salles FJ, Olympio KPK, Lucchini R, Fingerhut M, Violante FS, Seneviratne M, Oakman J, Lo O, Alfredo CH, Bandini M, Silva-Junior JS, Martinez MC, Cotrim T, Omokhodion F, Fischer FM. Occupational Safety and Health Staging Framework for Decent Work. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph191710842. [PMID: 36078562 PMCID: PMC9518038 DOI: 10.3390/ijerph191710842] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/08/2022] [Revised: 08/24/2022] [Accepted: 08/25/2022] [Indexed: 05/05/2023]
Abstract
The 2030 United Nations Goal 8 for sustainable development focuses on decent work. There is utility in identifying the occupational safety and health aspects of Goal 8, as they pertain to the four pillars of decent work: job creation, social protection, rights of workers, and social dialogue. A workgroup of the International Commission on Occupational Health and collaborators addressed the issue of decent work and occupational safety and health (OSH) with the objective of elaborating a framework for guidance for practitioners, researchers, employers, workers, and authorities. This article presents that framework, which is based on an examination of the literature and the perspectives of the workgroup. The framework encompasses the intersection of the pillars of decent (employment creation, social protection, rights of workers, and social dialogue) work with new and emerging hazards and risks related to various selected determinants: new technologies and new forms of work; demographics (aging and gender); globalization; informal work; migration; pandemics; and OSH policies and climate change. The OSH field will need an expanded focus to address the future of decent work. This focus should incorporate the needs of workers and workforces in terms of their well-being. The framework identifies a starting point for the OSH community to begin to promote decent work.
Collapse
Affiliation(s)
- Paul A. Schulte
- Advanced Technologies and Laboratories International, Inc., Gaithersburg, MD 20878, USA
| | - Ivo Iavicoli
- Section of Occupational Medicine, Department of Public Health, University of Naples Federico II, 80131 Naples, Italy
- Correspondence: ; Tel.: +39-081-7462430
| | - Luca Fontana
- Section of Occupational Medicine, Department of Public Health, University of Naples Federico II, 80131 Naples, Italy
| | - Stavroula Leka
- Business School, University College Cork, T12 K8AF Cork, Ireland
| | - Maureen F. Dollard
- PSC Global Observatory, University of South Australia, Adelaide, SA 5000, Australia
| | - Acran Salmen-Navarro
- Department of Population Health, NYU Grossman School of Medicine, New York, NY 10016, USA
| | - Fernanda J. Salles
- Department of Environmental Health, School of Public Health, University of São Paulo, São Paulo 01246-904, Brazil
| | - Kelly P. K. Olympio
- Department of Environmental Health, School of Public Health, University of São Paulo, São Paulo 01246-904, Brazil
| | - Roberto Lucchini
- Environmental Health Sciences, School of Public Health, Florida International University, Miami, FL 33199, USA
- Occupational Medicine, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Brescia, 25121 Brescia, Italy
| | - Marilyn Fingerhut
- Advanced Technologies and Laboratories International, Inc., Gaithersburg, MD 20878, USA
| | - Francesco S. Violante
- Department of Medical and Surgical Sciences, University of Bologna, 40138 Bologna, Italy
| | | | - Jodi Oakman
- Center for Ergonomics and Human Factors, LaTrobe University, Melbourne, VIC 3086, Australia
| | - Olivier Lo
- Medical Services Division, International SOS, Singapore 486018, Singapore
| | - Camila H. Alfredo
- Department of Environmental Health, School of Public Health, University of São Paulo, São Paulo 01246-904, Brazil
| | - Marcia Bandini
- Department of Public Health, School of Medicine, University of Campinas, Campinas 13083-970, Brazil
| | | | | | - Teresa Cotrim
- Ergonomics Laboratory, CIAUD, Faculdade de Motricidade Humana, University of Lisbon, 1499-002 Lisbon, Portugal
| | - Folashade Omokhodion
- Division of Occupational Health, College of Medicine, University of Ibadan, Ibadan 200132, Nigeria
| | - Frida M. Fischer
- Department of Environmental Health, School of Public Health, University of São Paulo, São Paulo 01246-904, Brazil
| |
Collapse
|
9
|
Turner AL, Brokamp C, Wolfe C, Reponen T, Brunst KJ, Ryan PH. Mental and Physical Stress Responses to Personal Ultrafine Particle Exposure in Adolescents. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph19127509. [PMID: 35742759 PMCID: PMC9223710 DOI: 10.3390/ijerph19127509] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/14/2022] [Revised: 06/14/2022] [Accepted: 06/15/2022] [Indexed: 02/05/2023]
Abstract
Incidence rates of mental health disorders among adolescents is increasing, indicating a strong need for effective prevention efforts at a population level. The etiology of mental health disorders includes genetic, social, and environmental factors. Ultrafine particles (UFPs; particles less than 0.1 μm in diameter) have been shown to exert neurotoxic effects on the brain; however, epidemiologic evidence on the relationship between UFPs and childhood mental health outcomes is unclear. The objective of this study was to determine if exposure to UFPs was associated with symptoms of mental health in adolescents. Adolescents completed personal UFP monitoring for one week as well as a series of validated Patient-Reported Outcomes Measurement Information System (PROMIS) assessments to measure five domains of mental and physical stress symptoms. Multivariable linear regression models were used to estimate the association between PROMIS domain T-scores and median weekly personal UFP exposure with the inclusion of interactions to explore sex differences. We observed that median weekly UFP exposure was significantly associated with physical stress symptoms (β: 5.92 per 10-fold increase in UFPs, 95% CI [0.72, 11.13]) but no other measured domains. Further, we did not find effect modification by sex on any of the PROMIS outcomes. The results of this study indicate UFPs are associated with physical symptoms of stress response among adolescents, potentially contributing to mental health disorders in this population.
Collapse
Affiliation(s)
- Ashley L. Turner
- Division of Biostatistics and Epidemiology, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH 45229, USA; (C.B.); (C.W.); (P.H.R.)
- Correspondence: ; Tel.: +1-630-306-2259
| | - Cole Brokamp
- Division of Biostatistics and Epidemiology, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH 45229, USA; (C.B.); (C.W.); (P.H.R.)
- Department of Pediatrics, College of Medicine, University of Cincinnati, Cincinnati, OH 45221, USA
| | - Chris Wolfe
- Division of Biostatistics and Epidemiology, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH 45229, USA; (C.B.); (C.W.); (P.H.R.)
| | - Tiina Reponen
- Department of Environmental and Public Health Sciences, College of Medicine, University of Cincinnati, Cincinnati, OH 45221, USA; (T.R.); (K.J.B.)
| | - Kelly J. Brunst
- Department of Environmental and Public Health Sciences, College of Medicine, University of Cincinnati, Cincinnati, OH 45221, USA; (T.R.); (K.J.B.)
| | - Patrick H. Ryan
- Division of Biostatistics and Epidemiology, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH 45229, USA; (C.B.); (C.W.); (P.H.R.)
- Department of Pediatrics, College of Medicine, University of Cincinnati, Cincinnati, OH 45221, USA
| |
Collapse
|
10
|
Pétremand R, Suárez G, Besançon S, Dil JH, Guseva Canu I. A Real-Time Comparison of Four Particulate Matter Size Fractions in the Personal Breathing Zone of Paris Subway Workers: A Six-Week Prospective Study. SUSTAINABILITY 2022; 14:5999. [PMID: 35909454 PMCID: PMC9170000 DOI: 10.3390/su14105999] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/19/2022] [Accepted: 05/13/2022] [Indexed: 01/11/2023]
Abstract
We developed a Bayesian spline model for real-time mass concentrations of particulate matter (PM10, PM2.5, PM1, and PM0.3) measured simultaneously in the personal breathing zone of Parisian subway workers. The measurements were performed by GRIMM, a gravimetric method, and DiSCmini during the workers’ work shifts over two consecutive weeks. The measured PM concentrations were analyzed with respect to the working environment, the underground station, and any specific events that occurred during the work shift. Overall, PM0.3 concentrations were more than an order of magnitude lower compared to the other PM concentrations and showed the highest temporal variation. The PM2.5 levels raised the highest exposure concern: 15 stations out of 37 had higher mass concentrations compared to the reference. Station PM levels were not correlated with the annual number of passengers entering the station, the year of station opening or renovation, or the number of platforms and tracks. The correlation with the number of station entrances was consistently negative for all PM sizes, whereas the number of correspondence concourses was negatively correlated with PM0.3 and PM10 levels and positively correlated with PM1 and PM2.5 levels. The highest PM10 exposure was observed for the station platform, followed by the subway cabin and train, while ticket counters had the highest PM0.3, PM1, and PM2.5 mass concentrations. We further found that compared to gravimetric and DiSCmini measurements, GRIMM results showed some discrepancies, with an underestimation of exposure levels. Therefore, we suggest using GRIMM, calibrated by gravimetric methods, for PM sizes above 1μm, and DiSCmini for sizes below 700 nm.
Collapse
Affiliation(s)
- Rémy Pétremand
- Department of Occupational and Environmental Health, Center of Primary Care and Public Health (Unisanté), University of Lausanne, Epalinges, 1066 Lausanne, Switzerland; (R.P.); (G.S.)
| | - Guillaume Suárez
- Department of Occupational and Environmental Health, Center of Primary Care and Public Health (Unisanté), University of Lausanne, Epalinges, 1066 Lausanne, Switzerland; (R.P.); (G.S.)
| | - Sophie Besançon
- Régie Automne de Transport Parisien (RATP), 75012 Paris, France;
| | - J Hugo Dil
- Institute of Physics, Ecole Polytechnique Fédérale de Lausanne (EPFL), 1015 Lausanne, Switzerland;
| | - Irina Guseva Canu
- Department of Occupational and Environmental Health, Center of Primary Care and Public Health (Unisanté), University of Lausanne, Epalinges, 1066 Lausanne, Switzerland; (R.P.); (G.S.)
| |
Collapse
|
11
|
Kumoi J, Ikegami A, Fujitani Y, Morikawa K, Ichihara G, Yano T, Ichihara S. Factory site analysis of respirable fibers generated during the process of cutting and grinding of carbon fibers-reinforced plastics. Int Arch Occup Environ Health 2022; 95:1557-1565. [PMID: 35212801 DOI: 10.1007/s00420-022-01840-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2021] [Accepted: 02/01/2022] [Indexed: 11/26/2022]
Abstract
OBJECTIVES Carbon fibers are used in a variety of industrial applications, based on their lightweight and high stiffness properties. There is little information on the characteristics and exposure levels of debris generated during the factory processing of carbon fibers or their composites. This study revisits the general assumption that carbon fibers or their debris released during composite processing are considered safe for human health. METHODS The present interventional study was conducted at a factory located in Japan, and involved on-site collection of debris generated during the industrial processing of polyacrylonitrile (PAN)-based carbon-fiber-reinforced plastic (CFRP). The debris were collected before being exhausted locally from around different factory machines and examined morphologically and quantitatively by scanning electron microscopy. The levels of exposure to respirable carbon fibers at different areas of the factory were also quantified. RESULTS The collected debris mainly contained the original carbon fibers broken transversely at the fiber's major axis. However, carbon fiber fragments morphologically compatible with the WHO definition of respirable fibers (length: > 5 μm, width: < 3 μm, length/width ratio: > 3:1) were also found. The concentrations of respirable fibers at the six examined factory areas under standard working conditions in the same factory were below the standard limit of 10 fibers/L, specified for asbestos dust-generating facilities under the Air Pollution Control Law in Japan. CONCLUSIONS Our study identified potentially dangerous respirable fibers with high aspect ratio, which was generated during the processing of PAN-based CFRP. Regular risk assessment of carbon fiber debris is necessary to ensure work environment safety.
Collapse
Affiliation(s)
- Jun Kumoi
- Graduate School of Regional Innovation Studies, Mie University, 1577 Kurimamachiya-cho, Tsu, 514-8507, Japan
| | - Akihiko Ikegami
- Department of Environmental and Preventive Medicine, Jichi Medical University School of Medicine, 3311-1 Yakushiji, Shimotsuke, 329-0498, Japan
| | - Yuji Fujitani
- National Institute for Environmental Studies, 16-2 Onogawa, Tsukuba, 305-8506, Japan
| | - Kota Morikawa
- Department of Occupational and Environmental Health, Tokyo Univeristy of Science, 2641 Yamazaki, Noda, 278-0022, Japan
| | - Gaku Ichihara
- Department of Occupational and Environmental Health, Tokyo Univeristy of Science, 2641 Yamazaki, Noda, 278-0022, Japan
| | - Takeo Yano
- Graduate School of Regional Innovation Studies, Mie University, 1577 Kurimamachiya-cho, Tsu, 514-8507, Japan
| | - Sahoko Ichihara
- Graduate School of Regional Innovation Studies, Mie University, 1577 Kurimamachiya-cho, Tsu, 514-8507, Japan.
- Department of Environmental and Preventive Medicine, Jichi Medical University School of Medicine, 3311-1 Yakushiji, Shimotsuke, 329-0498, Japan.
| |
Collapse
|
12
|
Del Secco B, Trabucco S, Ravegnani F, Koivisto AJ, Zanoni I, Blosi M, Ortelli S, Altin M, Bartolini G, Costa AL, Belosi F. Particles Emission from an Industrial Spray Coating Process Using Nano-Materials. NANOMATERIALS 2022; 12:nano12030313. [PMID: 35159658 PMCID: PMC8838285 DOI: 10.3390/nano12030313] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/21/2021] [Revised: 12/16/2021] [Accepted: 01/13/2022] [Indexed: 01/08/2023]
Abstract
Industrial spray coating processes are known to produce excellent coatings on large surfaces and are thus often used for in-line production. However, they could be one of the most critical sources of worker exposure to ultrafine particles (UFPs). A monitoring campaign at the Witek s.r.l. (Florence, Italy) was deployed to characterize the release of TiO2 NPs doped with nitrogen (TiO2-N) and Ag capped with hydroxyethyl cellulose (AgHEC) during automatic industrial spray-coating of polymethyl methacrylate (PMMA) and polyester. Aerosol particles were characterized inside the spray chamber at near field (NF) and far field (FF) locations using on-line and off-line instruments. Results showed that TiO2-N suspension produced higher particle number concentrations than AgHEC in the size range 0.3–1 µm (on average 1.9 102 p/cm3 and 2.5 101 p/cm3, respectively) after background removing. At FF, especially at worst case scenario (4 nozzles, 800 mL/min flow rate) for TiO2-N, the spray spikes were correlated with NF, with an observed time lag of 1 minute corresponding to a diffusion speed of 0.1 m/s. The averaged ratio between particles mass concentrations in the NF position and inside the spray chamber was 1.7% and 1.5% for TiO2-N and for AgHEC suspensions, respectively. The released particles’ number concentration of TiO2-N in the size particles range 0.3–1 µm was comparable for both PMMA and polyester substrates, about 1.5 and 1.6 102 p/cm3. In the size range 0.01–30 µm, the aerosol number concentration at NF for both suspensions was lower than the nano reference values (NRVs) of 16·103 p/cm-3.
Collapse
Affiliation(s)
- Benedetta Del Secco
- CNR-ISAC, Institute of Atmospheric Sciences and Climate-National Research Council of Italy, Via Gobetti, 101, 40129 Bologna, Italy; (S.T.); (F.R.); (F.B.)
- Correspondence:
| | - Sara Trabucco
- CNR-ISAC, Institute of Atmospheric Sciences and Climate-National Research Council of Italy, Via Gobetti, 101, 40129 Bologna, Italy; (S.T.); (F.R.); (F.B.)
| | - Fabrizio Ravegnani
- CNR-ISAC, Institute of Atmospheric Sciences and Climate-National Research Council of Italy, Via Gobetti, 101, 40129 Bologna, Italy; (S.T.); (F.R.); (F.B.)
| | | | - Ilaria Zanoni
- CNR-ISTEC, Institute of Science and Technology for Ceramics-National Research Council of Italy, Via Granarolo 64, 48018 Faenza, Italy; (I.Z.); (M.B.); (S.O.); (A.L.C.)
| | - Magda Blosi
- CNR-ISTEC, Institute of Science and Technology for Ceramics-National Research Council of Italy, Via Granarolo 64, 48018 Faenza, Italy; (I.Z.); (M.B.); (S.O.); (A.L.C.)
| | - Simona Ortelli
- CNR-ISTEC, Institute of Science and Technology for Ceramics-National Research Council of Italy, Via Granarolo 64, 48018 Faenza, Italy; (I.Z.); (M.B.); (S.O.); (A.L.C.)
| | - Marko Altin
- Witek srl., Via Siena 47, 50142 Firenze, Italy; (M.A.); (G.B.)
| | | | - Anna Luisa Costa
- CNR-ISTEC, Institute of Science and Technology for Ceramics-National Research Council of Italy, Via Granarolo 64, 48018 Faenza, Italy; (I.Z.); (M.B.); (S.O.); (A.L.C.)
| | - Franco Belosi
- CNR-ISAC, Institute of Atmospheric Sciences and Climate-National Research Council of Italy, Via Gobetti, 101, 40129 Bologna, Italy; (S.T.); (F.R.); (F.B.)
| |
Collapse
|
13
|
López M, López Lilao A, Ribalta C, Martínez Y, Piña N, Ballesteros A, Fito C, Koehler K, Newton A, Monfort E, Viana M. Particle release from refit operations in shipyards: Exposure, toxicity and environmental implications. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 804:150216. [PMID: 34520930 DOI: 10.1016/j.scitotenv.2021.150216] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/29/2021] [Revised: 08/22/2021] [Accepted: 09/04/2021] [Indexed: 06/13/2023]
Abstract
European harbours are known to contribute to air quality degradation. While most of the literature focuses on emissions from stacks or logistics operations, ship refit and repair activities are also relevant aerosol sources in EU harbour areas. Main activities include abrasive removal of filler and spray painting with antifouling coatings/primers/topcoats. This work aimed to assess ultrafine particle (UFP) emissions from ship maintenance activities and their links with exposure, toxicity and health risks for humans and the aquatic environment. Aerosol emissions were monitored during mechanical abrasion of surface coatings under real-world operating conditions in two scenarios in the Mallorca harbour (Spain). Different types of UFPs were observed: (1) highly regular (triangular, hexagonal) engineered nanoparticles (Ti-, Zr-, Fe-based), embedded as nano-additives in the coatings, and (2) irregular, incidental particles emitted directly or formed during abrasion. Particle number concentrations monitored were in the range of industrial activities such as drilling or welding (up to 5 ∗ 105/cm3, mean diameters <30 nm). The chemical composition of PM4 aerosols was dominated by metallic tracers in the coatings (Ti, Al, Ba, Zn). In vitro toxicity of PM2 aerosols evidenced reduced cell viability and a moderate potential for cytotoxic effects. While best practices (exhaust ventilation, personal protective equipment, dust removal) were in place, it is unlikely that exposures and environmental release can be fully avoided at all times. Thus, it is advisable that health and safety protocols should be comprehensive to minimise exposures in all types of locations (near- and far-field) and periods (activity and non-activity). Potential release to coastal surface waters of metallic engineered and incidental nanomaterials, as well as fine and coarse particles (in the case of settled dust), should be assessed and avoided.
Collapse
Affiliation(s)
- M López
- Institute of Environmental Assessment and Water Research (IDAEA-CSIC), C/ Jordi Girona 18, 08034 Barcelona, Spain; Barcelona University, Chemistry Faculty, C/ de Martí i Franquès, 1-11, 08028 Barcelona, Spain.
| | - A López Lilao
- Institute of Ceramic Technology (ITC)- AICE - Universitat Jaume I, Campus Universitario Riu Sec, Av. Vicent Sos Baynat s/n, 12006 Castellón, Spain
| | - C Ribalta
- The National Research Center for Work Environment (NRCWE), Lersø Parkallé 105, 2100 København, Denmark
| | - Y Martínez
- Baleari Island University (UIB), Carretera de Valldemossa, km 7.5, 07122 Palma, Illes Balears, Spain
| | - N Piña
- Baleari Island University (UIB), Carretera de Valldemossa, km 7.5, 07122 Palma, Illes Balears, Spain
| | - A Ballesteros
- Technological Institute of Packaging, Transportation and Logistics (ITENE), C/ Albert Einstein, 1, 46980 Paterna, Valencia, Spain
| | - C Fito
- Technological Institute of Packaging, Transportation and Logistics (ITENE), C/ Albert Einstein, 1, 46980 Paterna, Valencia, Spain
| | - K Koehler
- Johns Hopkins University (JHU), Baltimore, MD 21218, USA
| | - A Newton
- Johns Hopkins University (JHU), Baltimore, MD 21218, USA
| | - E Monfort
- Institute of Ceramic Technology (ITC)- AICE - Universitat Jaume I, Campus Universitario Riu Sec, Av. Vicent Sos Baynat s/n, 12006 Castellón, Spain
| | - M Viana
- Institute of Environmental Assessment and Water Research (IDAEA-CSIC), C/ Jordi Girona 18, 08034 Barcelona, Spain
| |
Collapse
|
14
|
Buitrago E, Novello AM, Fink A, Riediker M, Rothen-Rutishauser B, Meyer T. NanoSafe III: A User Friendly Safety Management System for Nanomaterials in Laboratories and Small Facilities. NANOMATERIALS (BASEL, SWITZERLAND) 2021; 11:2768. [PMID: 34685208 PMCID: PMC8541324 DOI: 10.3390/nano11102768] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/18/2021] [Revised: 10/05/2021] [Accepted: 10/14/2021] [Indexed: 11/16/2022]
Abstract
Research in nanoscience continues to bring forward a steady stream of new nanomaterials and processes that are being developed and marketed. While scientific committees and expert groups deal with the harmonization of terminology and legal challenges, risk assessors in research labs continue to have to deal with the gap between regulations and rapidly developing information. The risk assessment of nanomaterial processes is currently slow and tedious because it is performed on a material-by-material basis. Safety data sheets are rarely available for (new) nanomaterials, and even when they are, they often lack nano-specific information. Exposure estimations or measurements are difficult to perform and require sophisticated and expensive equipment and personal expertise. The use of banding-based risk assessment tools for laboratory environments is an efficient way to evaluate the occupational risks associated with nanomaterials. Herein, we present an updated version of our risk assessment tool for working with nanomaterials based on a three-step control banding approach and the precautionary principle. The first step is to determine the hazard band of the nanomaterial. A decision tree allows the assignment of the material to one of three bands based on known or expected effects on human health. In the second step, the work exposure is evaluated and the processes are classified into three "nano" levels for each specific hazard band. The work exposure is estimated using a laboratory exposure model. The result of this calculation in combination with recommended occupational exposure limits (rOEL) for nanomaterials and an additional safety factor gives the final "nano" level. Finally, we update the technical, organizational, and personal protective measures to allow nanomaterial processes to be established in research environments.
Collapse
Affiliation(s)
- Elina Buitrago
- Ecole Polytechnique Fédérale de Lausanne (EPFL), Occupational Health and Safety (OHS), Station 6, CH-1015 Lausanne, Switzerland; (E.B.); (A.M.N.)
| | - Anna Maria Novello
- Ecole Polytechnique Fédérale de Lausanne (EPFL), Occupational Health and Safety (OHS), Station 6, CH-1015 Lausanne, Switzerland; (E.B.); (A.M.N.)
| | - Alke Fink
- BioNanomaterials, Adolphe Merkle Institute, University of Fribourg, Ch. des Verdiers 4, CH-1700 Fribourg, Switzerland; (A.F.); (B.R.-R.)
| | - Michael Riediker
- SCOEH: Swiss Centre for Occupational and Environmental Health, Binzhofstrasse 87, CH-8404 Winterthur, Switzerland;
| | - Barbara Rothen-Rutishauser
- BioNanomaterials, Adolphe Merkle Institute, University of Fribourg, Ch. des Verdiers 4, CH-1700 Fribourg, Switzerland; (A.F.); (B.R.-R.)
| | - Thierry Meyer
- Ecole Polytechnique Fédérale de Lausanne (EPFL), Group of Chemical and Physical Safety (ISIC-GSCP), Station 6, CH-1015 Lausanne, Switzerland
| |
Collapse
|
15
|
Viitanen AK, Kallonen K, Kukko K, Kanerva T, Saukko E, Hussein T, Hämeri K, Säämänen A. Technical control of nanoparticle emissions from desktop 3D printing. INDOOR AIR 2021; 31:1061-1071. [PMID: 33647162 DOI: 10.1111/ina.12791] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/23/2020] [Accepted: 12/24/2020] [Indexed: 05/05/2023]
Abstract
Material extrusion (ME) desktop 3D printing is known to strongly emit nanoparticles (NP), and the need for risk management has been recognized widely. Four different engineering control measures were studied in real-life office conditions by means of online NP measurements and indoor aerosol modeling. The studied engineering control measures were general ventilation, local exhaust ventilation (LEV), retrofitted enclosure, and retrofitted enclosure with LEV. Efficiency between different control measures was compared based on particle number and surface area (SA) concentrations from which SA concentration was found to be more reliable. The study found out that for regular or long-time use of ME desktop 3D printers, the general ventilation is not sufficient control measure for NP emissions. Also, the LEV with canopy hood attached above the 3D printer did not control the emission remarkably and successful position of the hood in relation to the nozzle was found challenging. Retrofitted enclosure attached to the LEV reduced the NP emissions 96% based on SA concentration. Retrofitted enclosure is nearly as efficient as enclosure attached to the LEV (reduction of 89% based on SA concentration) but may be considered more practical solution than enclosure with LEV.
Collapse
Affiliation(s)
| | - Kimmo Kallonen
- Institute for Atmospheric and Earth System Research (INAR), University of Helsinki, Helsinki, Finland
- Helsinki Institute of Physics (HIP), University of Helsinki, Helsinki, Finland
| | - Kirsi Kukko
- Department of Mechanical Engineering, Aalto University, Espoo, Finland
| | - Tomi Kanerva
- Finnish Institute of Occupational Health, Helsinki, Finland
| | | | - Tareq Hussein
- Institute for Atmospheric and Earth System Research (INAR), University of Helsinki, Helsinki, Finland
- Department of Physics, School of Science, University of Jordan, Amman, Jordan
| | - Kaarle Hämeri
- Institute for Atmospheric and Earth System Research (INAR), University of Helsinki, Helsinki, Finland
| | - Arto Säämänen
- Finnish Institute of Occupational Health, Helsinki, Finland
| |
Collapse
|
16
|
Oginawati K, Susetyo SH, Rosalyn FA, Kurniawan SB, Abdullah SRS. Risk analysis of inhaled hexavalent chromium (Cr 6+) exposure on blacksmiths from industrial area. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2021; 28:14000-14008. [PMID: 33201502 DOI: 10.1007/s11356-020-11590-6] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/10/2020] [Accepted: 11/09/2020] [Indexed: 06/11/2023]
Abstract
Chromium (Cr) is used as a mixture to improve strength and corrosion resistance. Milling and welding processes can expose workers to Cr through dermal exposure and inhalation. Cr exposure can be determined by urine testing. The purpose of this study was to analyze the concentration of Cr in urine (UCr) of workers. This study was carried out using a cross-sectional method. Sampling was conducted in the village of Mekarmaju, Bandung, Indonesia. The number of respondents included 30 blacksmiths, and the control group comprised 10 people who were not blacksmiths. Cr6+ exposure was measured using a personal sampling pump placed on the collar of the worker's shirt as a breathing zone and then analyzed using a UV-visible spectrophotometer. UCr was measured with a graphite furnace atomic absorption spectrophotometer. The measured Cr6+ concentration in the exposed working area ranged from 0.03 to 0.63 mg/m3, whereas that in non-exposed area ranged from 0.02 to 0.04 mg/m3. Results showed that 16 out of 30 blacksmiths had a UCr concentration above the biological exposure index (BEI) value, 21 had a higher value than the threshold limit value (TLV), and 22 had hazard index (HI) values > 1, which indicated that Cr has a hazardous potential in the body. The analysis of the exposed and control groups showed a significant difference with a p value of 0.000 for TLV, chronic daily intake, and UCr. These results clearly showed that Cr6+ exposure may harm the health of these workers in the future. The results obtained in this study can be used to promote workers' awareness on the potential health risk caused by Cr6+ exposure in the working environment.
Collapse
Affiliation(s)
- Katharina Oginawati
- Department of Environmental Engineering, Faculty of Civil and Environmental, Institut Teknologi Bandung, Jl. Ghanesa No 10, Bandung, West Java, Indonesia
| | - Septian Hadi Susetyo
- Department of Environmental Engineering, Faculty of Civil and Environmental, Institut Teknologi Bandung, Jl. Ghanesa No 10, Bandung, West Java, Indonesia.
| | - Fiona Aulia Rosalyn
- Department of Environmental Engineering, Faculty of Civil and Environmental, Institut Teknologi Bandung, Jl. Ghanesa No 10, Bandung, West Java, Indonesia
| | - Setyo Budi Kurniawan
- Department of Chemical and Process Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, UKM, 43600, Bangi, Selangor, Malaysia
| | - Siti Rozaimah Sheikh Abdullah
- Department of Chemical and Process Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, UKM, 43600, Bangi, Selangor, Malaysia
| |
Collapse
|
17
|
Iavicoli I, Fontana L, Leso V, Macrini MC, Pelclova D. Fractional Exhaled Nitric Oxide and Nanomaterial Exposure in Workplaces. Curr Med Chem 2020; 27:7200-7212. [DOI: 10.2174/0929867327666200320154545] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2019] [Revised: 02/07/2020] [Accepted: 02/26/2020] [Indexed: 12/20/2022]
Abstract
Background:
The widespread application of engineered nanomaterials (ENMs) and the
increasing likelihood of general and occupational exposure raised concerns on their possible human
health impact. ENMs, in fact, may induce alterations in different organ systems, and particularly in
the respiratory tract. This makes it important to identify possible biomarkers of early lung effect in
exposed workers. In this regard, the possibility to use the fractional exhaled levels of nitric oxide
(FENO) in biological monitoring has attracted considerable interest.
Objective:
To comprehensively assess the role of FENO as a possible biomarker of lung effect in
ENM exposed workers.
Methods:
A systematic search was performed on Pubmed, Scopus, and ISI Web of Knowledge
databases according to the PRISMA guidelines.
Results:
Seven studies investigated FENO in workers exposed to different kinds of metal-(i.e.
silver and gold), metal oxide- (titanium and silica dioxide), and carbon-based ENMs (carbon nanotubes).
In general, no significant alterations were detected between exposed workers and controls.
Conclusions:
Definite conclusion on the function of FENO in occupational biological monitoring
cannot be extrapolated due to the limited number of available studies and the small size of investigated
populations. Additionally, the lack of environmental monitoring data and the fragmented
knowledge on ENM modes of action prevent to establish dose-response relationships. Future research
appears necessary to deeply define the possibility to employ FENO as an early biomarker of
lung effects taking in consideration possible occupational exposure issues, i.e. differently characterized
ENMs and work tasks, as well as individual influencing factors, i.e. smoking and atopy.
Collapse
Affiliation(s)
- Ivo Iavicoli
- Department of Public Health, Section of Occupational Medicine, University of Naples Federico II, Via S. Pansini 5, 80131 Naples, Italy
| | - Luca Fontana
- Department of Public Health, Section of Occupational Medicine, University of Naples Federico II, Via S. Pansini 5, 80131 Naples, Italy
| | - Veruscka Leso
- Department of Public Health, Section of Occupational Medicine, University of Naples Federico II, Via S. Pansini 5, 80131 Naples, Italy
| | - Maria Carmela Macrini
- Department of Public Health, Section of Occupational Medicine, University of Naples Federico II, Via S. Pansini 5, 80131 Naples, Italy
| | - Daniela Pelclova
- Department of Occupational Medicine, First Faculty of Medicine, Charles University and General University Hospital, Na Bojisti 1, 120,00 Prague, Czech Republic
| |
Collapse
|
18
|
Galey L, Audignon-Durand S, Brochard P, Debia M, Lacourt A, Lambert P, Le Bihan O, Martinon L, Pasquereau P, Witschger O, Garrigou A. Vers une méthode opérationnelle d’évaluation de l’exposition aux aérosols de nanoparticules par l’intégration de l’activité de travail à la mesure. ARCH MAL PROF ENVIRO 2020. [DOI: 10.1016/j.admp.2020.03.831] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
19
|
Additively Manufactured Parametric Universal Clip-System: An Open Source Approach for Aiding Personal Exposure Measurement in the Breathing Zone. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10196671] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Abstract
Design for additive manufacturing is adopted to help solve problems inherent to attaching active personal sampler systems to workers for monitoring their breathing zone. A novel and parametric 3D printable clip system was designed with an open source Computer-aided design (CAD) system and was additively manufactured. The concept was first tested with a simple clip design, and when it was found to be functional, the ability of the innovative and open source design to be extended to other applications was demonstrated by designing another tooling system. The clip system was tested for mechanical stress test to establish a minimum lifetime of 5000 openings, a cleaning test, and a supply chain test. The designs were also tested three times in field conditions. The design cost and functionalities of the clip system were compared to commercial systems. This study presents an innovative custom-designed clip system that can aid in attaching different tools for personal exposure measurement to a worker’s harness without hindering the operation of the worker. The customizable clip system opens new possibilities for occupational health professionals since the basic design can be altered to hold different kinds of samplers and tools. The solution is shared using an open source methodology.
Collapse
|
20
|
Cheristanidis S, Grivas G, Chaloulakou A. Determination of total and lung-deposited particle surface area concentrations, in central Athens, Greece. ENVIRONMENTAL MONITORING AND ASSESSMENT 2020; 192:627. [PMID: 32901375 DOI: 10.1007/s10661-020-08569-8] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/10/2020] [Accepted: 08/24/2020] [Indexed: 06/11/2023]
Abstract
Numerous health studies have linked the exposure to particulate matter with adverse health effects, while there is an increasing scientific interest in the particle metrics of surface area (SA) and lung-deposited SA (LDSA) concentration. In the present study, two integrated SA estimation methods, both based on widely used instrumentation, were applied at an urban traffic environment in Athens for a 6-month period. The first estimation method used the size distribution by number to estimate SA (average SA1 669.3 ± 229.0 μm2 cm-3), while the second method used a simple inversion scheme that incorporates number and mass concentrations (average SA2 1627.9 ± 562.8 μm2 cm-3). In pairwise comparisons, SA2 levels were found two times greater than the corresponding SA1, but exhibited a strong correlation (r = 0.73). SA1 and SA2 concentrations correlated well with the traffic-related pollutants NOx (r = 0.64 and 0.78) and equivalent black carbon (r = 0.53 and 0.51). The diurnal variation of SA1 concentrations by size range indicated traffic as a major controlling factor. Estimated LDSA (53.9 μm2 cm-3 on average) concentrations were also clearly affected by anthropogenic emissions with more pronounced associations in the 0.01-0.4 μm range (r = 0.66 with NOx and r = 0.65 with equivalent black carbon). Validating estimated LDSA through simultaneous measurements with a reference instrument revealed that the estimation method underestimates LDSA by a factor between 2 and 3, exhibiting, however, a high correlation (r = 0.79). Overall, the performance of estimation methods appear satisfactory and indicate that a trustworthy assessment of the temporal variability of SA and LDSA concentration metrics can be provided in real time, on the basis of relatively lower-cost instrumentation, especially in view of recent advances in particle sensing technologies.
Collapse
Affiliation(s)
- Stavros Cheristanidis
- School of Chemical Engineering, National Technical University of Athens, 15780, Zografos, Athens, Greece.
| | - Georgios Grivas
- Institute for Environmental Research and Sustainable Development, National Observatory of Athens, 15236, Athens, Greece
| | - Archontoula Chaloulakou
- School of Chemical Engineering, National Technical University of Athens, 15780, Zografos, Athens, Greece
| |
Collapse
|
21
|
Galey L, Audignon S, Witschger O, Bau S, Judon N, Lacourt A, Garrigou A. What does ergonomics have to do with nanotechnologies? A case study. APPLIED ERGONOMICS 2020; 87:103116. [PMID: 32501248 DOI: 10.1016/j.apergo.2020.103116] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/31/2018] [Revised: 03/04/2020] [Accepted: 04/06/2020] [Indexed: 06/11/2023]
Abstract
Despite recent concerns for workers' health, exposure situations to nanoparticles can occur in numerous workplaces. Understanding how exposures occur considering human work in these transformations remains a crucial issue of nanotechnologies. The objective of this article is to understand exposure situations to nanoparticles, their determinants and the resources to act on them. This understanding was achieved by specific measurement of nanoparticles aerosols, combined with an analysis of work activity (actions performed and physical strain) in a rubber industry. The presentation of real time measurements, associated with the video of work situations, during confrontation interviews becomes a means of making exposing work activities visible, to analyze and transform them from the points of view formulated by the company's stakeholders. In this way, characterized "typical exposure situations" serve to trigger discussions and open up new spaces for debate highlighting how innovation affects work and gives rise to enhanced prevention projects.
Collapse
Affiliation(s)
- Louis Galey
- Univ. Bordeaux, Inserm, Bordeaux Population Health Research Center, team EPICENE, UMR 1219, 146 rue Léo Saignat, F-33000, Bordeaux, France.
| | - Sabyne Audignon
- Univ. Bordeaux, Inserm, Bordeaux Population Health Research Center, team EPICENE, UMR 1219, 146 rue Léo Saignat, F-33000, Bordeaux, France
| | - Olivier Witschger
- Institut National de Recherche et de Sécurité (INRS), Rue du Morvan, CS 60027, 54500, Vandoeuvre Les Nancy, France
| | - Sébastien Bau
- Institut National de Recherche et de Sécurité (INRS), Rue du Morvan, CS 60027, 54500, Vandoeuvre Les Nancy, France
| | - Nathalie Judon
- Institut National de Recherche et de Sécurité (INRS), Rue du Morvan, CS 60027, 54500, Vandoeuvre Les Nancy, France
| | - Aude Lacourt
- Univ. Bordeaux, Inserm, Bordeaux Population Health Research Center, team EPICENE, UMR 1219, 146 rue Léo Saignat, F-33000, Bordeaux, France
| | - Alain Garrigou
- Univ. Bordeaux, Inserm, Bordeaux Population Health Research Center, team EPICENE, UMR 1219, 146 rue Léo Saignat, F-33000, Bordeaux, France
| |
Collapse
|
22
|
Buitrago E, Novello AM, Meyer T. Third‐Generation Solar Cells: Toxicity and Risk of Exposure. Helv Chim Acta 2020. [DOI: 10.1002/hlca.202000074] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Elina Buitrago
- Ecole Polytechnique Fédérale de Lausanne (EPFL) Safety Competence Center (DSPS-SCC) Station 6 CH-1015 Lausanne Switzerland
- Ecole Polytechnique Fédérale de Lausanne (EPFL) Group of Chemical and Physical Safety (ISIC-GSCP) Station 6 CH-1015 Lausanne Switzerland
| | - Anna Maria Novello
- Ecole Polytechnique Fédérale de Lausanne (EPFL) Safety Competence Center (DSPS-SCC) Station 6 CH-1015 Lausanne Switzerland
- Ecole Polytechnique Fédérale de Lausanne (EPFL) Group of Chemical and Physical Safety (ISIC-GSCP) Station 6 CH-1015 Lausanne Switzerland
| | - Thierry Meyer
- Ecole Polytechnique Fédérale de Lausanne (EPFL) Safety Competence Center (DSPS-SCC) Station 6 CH-1015 Lausanne Switzerland
- Ecole Polytechnique Fédérale de Lausanne (EPFL) Group of Chemical and Physical Safety (ISIC-GSCP) Station 6 CH-1015 Lausanne Switzerland
| |
Collapse
|
23
|
Vimercati L, Cavone D, Caputi A, De Maria L, Tria M, Prato E, Ferri GM. Nanoparticles: An Experimental Study of Zinc Nanoparticles Toxicity on Marine Crustaceans. General Overview on the Health Implications in Humans. Front Public Health 2020; 8:192. [PMID: 32509719 PMCID: PMC7253631 DOI: 10.3389/fpubh.2020.00192] [Citation(s) in RCA: 35] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2019] [Accepted: 04/27/2020] [Indexed: 01/05/2023] Open
Abstract
The presence of products containing nanoparticles or nanofibers is rapidly growing. Nanotechnology involves a wide spectrum of industrial fields. There is a lack of information regarding the toxicity of these nanoparticles in aqueous media. The potential acute toxicity of ZnO NPs using two marine crustacean species: the copepod Tigriopus fulvus and the amphypod Corophium insidiosum was evaluated. Acute tests were conducted on adults of T. Fulvus nauplii and C. insidiosum. Both test species were exposed for 96 h to 5 increasing concentrations of ZnO NPs and ZnSO4H2O, and the endpoint was mortality. Statistical analysis revealed that the mean LC50 values of both ZnO NPs and ZnSO4H2O (ZnO NPs: F = 59.42; P < 0.0015; ZnSO4H2O: F = 25.57; P < 0.0015) were significantly lower for Tigriopus fulvus than for Corophium insidiosum. This result confirms that the toxic effect could be mainly attributed to the Zn ions, confirming that the dissolution processes play a crucial role in the toxicity of the ZnO NPs.
Collapse
Affiliation(s)
- Luigi Vimercati
- Unit of Occupational Medicine, Interdisciplinary Department of Medicine (DIM), School of Medicine, University Hospital “Policlinico”, University of Bari “A. Moro”, Bari, Italy
| | - Domenica Cavone
- Unit of Occupational Medicine, Interdisciplinary Department of Medicine (DIM), School of Medicine, University Hospital “Policlinico”, University of Bari “A. Moro”, Bari, Italy
| | - Antonio Caputi
- Unit of Occupational Medicine, Interdisciplinary Department of Medicine (DIM), School of Medicine, University Hospital “Policlinico”, University of Bari “A. Moro”, Bari, Italy
| | - Luigi De Maria
- Unit of Occupational Medicine, Interdisciplinary Department of Medicine (DIM), School of Medicine, University Hospital “Policlinico”, University of Bari “A. Moro”, Bari, Italy
| | - Michele Tria
- Marine Environment and Pollution Prevention, Department of Prevention, ASL TA Health Company, Taranto, Italy
| | - Ermelinda Prato
- Institute for the Coastal Marine Environment of the Italian National Research Council (IAMC-CNR), Taranto, Italy
| | - Giovanni Maria Ferri
- Unit of Occupational Medicine, Interdisciplinary Department of Medicine (DIM), School of Medicine, University Hospital “Policlinico”, University of Bari “A. Moro”, Bari, Italy
| |
Collapse
|
24
|
Eisazadeh H, Ehteram MA, Khazaee I. Diffusion charging measurements on exhaust solid particle number and lung deposited surface area of compressed natural gas and diesel buses. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2020; 27:16929-16939. [PMID: 32144706 DOI: 10.1007/s11356-020-08266-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/11/2019] [Accepted: 02/27/2020] [Indexed: 06/10/2023]
Abstract
Because of their direct contact with society, urban buses are prioritized targets for air quality improvement. In this study, a sample group of in-use urban old buses powered by compressed natural gas (CNG) and diesel engines was chosen for particle emission analysis. The CNG buses do not have any type of after-treatment, while diesel ones are equipped with a diesel particulate filter (DPF). To measure the lung deposited surface area (LDSA), a possible physical metric of exhaust particles' toxicity, a diffusion charger-based analyzer was utilized. The measurements were done at different engine speeds in stationary conditions. The results revealed that although the particle mass emission of CNG buses remains at a low level, the number of emitted particles for 75% of the CNG buses (depending on their maintenance conditions) is 10 to 100 times more than the retrofitted diesel ones, with the range of 106 to 107 p/cm3. The rest 25% of the CNG buses were performing the same as the retrofitted diesel ones in terms of exhaust particle number in the range of 105 p/cm3. In addition, the lowest LDSA parameter at low idle engine speed was measured to be 97.8 and 229.4 μm2/cm3 for a CNG and a DPF retrofitted diesel bus, respectively. This result indicates the same and even lower LDSA and surface area and thus the lower possible toxic potentiality of exhaust particles of CNG buses compared to diesel vehicles at DPF downstream. Investigation on the different behavior of the CNG buses in the emission of particles showed the correlation of some aging parameters such as lubricant oil aging mileage with the released particles and the importance of periodic maintenance interval. Graphical abstract.
Collapse
Affiliation(s)
- Hessam Eisazadeh
- Faculty of Mechanical and Energy Engineering, Shahid Beheshti University, Tehran, Iran
| | - Mohammad Ali Ehteram
- Faculty of Mechanical and Energy Engineering, Shahid Beheshti University, Tehran, Iran.
| | - Iman Khazaee
- Faculty of Mechanical and Energy Engineering, Shahid Beheshti University, Tehran, Iran
| |
Collapse
|
25
|
Bessa MJ, Brandão F, Viana M, Gomes JF, Monfort E, Cassee FR, Fraga S, Teixeira JP. Nanoparticle exposure and hazard in the ceramic industry: an overview of potential sources, toxicity and health effects. ENVIRONMENTAL RESEARCH 2020; 184:109297. [PMID: 32155489 DOI: 10.1016/j.envres.2020.109297] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/15/2019] [Revised: 02/22/2020] [Accepted: 02/23/2020] [Indexed: 06/10/2023]
Abstract
The ceramic industry is an industrial sector of great impact in the global economy that has been benefiting from advances in materials and processing technologies. Ceramic manufacturing has a strong potential for airborne particle formation and emission, namely of ultrafine particles (UFP) and nanoparticles (NP), meaning that workers of those industries are at risk of potential exposure to these particles. At present, little is known on the impact of engineered nanoparticles (ENP) on the environment and human health and no established Occupational Exposure Limits (OEL) or specific regulations to airborne nanoparticles (ANP) exposure exist raising concerns about the possible consequences of such exposure. In this paper, we provide an overview of the current knowledge on occupational exposure to NP in the ceramic industry and their impact on human health. Possible sources and exposure scenarios, a summary of the existing methods for evaluation and monitoring of ANP in the workplace environment and proposed Nano Reference Values (NRV) for different classes of NP are presented. Case studies on occupational exposure to ANP generated at different stages of the ceramic manufacturing process are described. Finally, the toxicological potential of intentional and unintentional ANP that have been identified in the ceramic industry workplace environment is discussed based on the existing evidence from in vitro and in vivo inhalation toxicity studies.
Collapse
Affiliation(s)
- Maria João Bessa
- Instituto Nacional de Saúde Doutor Ricardo Jorge, Departamento de Saúde Ambiental, Porto, Portugal; EPIUnit - Instituto de Saúde Pública, Universidade do Porto, Porto, Portugal; Instituto de Ciências Biomédicas Abel Salazar, Universidade do Porto, Porto, Portugal.
| | - Fátima Brandão
- Instituto Nacional de Saúde Doutor Ricardo Jorge, Departamento de Saúde Ambiental, Porto, Portugal; EPIUnit - Instituto de Saúde Pública, Universidade do Porto, Porto, Portugal.
| | - Mar Viana
- Institute of Environmental Assessment and Water Research (IDÆA-CSIC), Barcelona, Spain.
| | - João F Gomes
- CERENA, Centro de Recursos Naturais e Ambiente/Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal; ISEL - Instituto Superior de Engenharia de Lisboa, Lisboa, Portugal.
| | - Eliseo Monfort
- Institute of Ceramic Technology (ITC), Universitat Jaume I, 12006, Castellón, Spain.
| | - Flemming R Cassee
- National Institute for Public Health and the Environment, Bilthoven, the Netherlands; Institute for Risk Assessment Studies, Utrecht University, Utrecht, the Netherlands.
| | - Sónia Fraga
- Instituto Nacional de Saúde Doutor Ricardo Jorge, Departamento de Saúde Ambiental, Porto, Portugal; EPIUnit - Instituto de Saúde Pública, Universidade do Porto, Porto, Portugal.
| | - João Paulo Teixeira
- Instituto Nacional de Saúde Doutor Ricardo Jorge, Departamento de Saúde Ambiental, Porto, Portugal; EPIUnit - Instituto de Saúde Pública, Universidade do Porto, Porto, Portugal.
| |
Collapse
|
26
|
Forehead H, Barthelemy J, Arshad B, Verstaevel N, Price O, Perez P. Traffic exhaust to wildfires: PM2.5 measurements with fixed and portable, low-cost LoRaWAN-connected sensors. PLoS One 2020; 15:e0231778. [PMID: 32330173 PMCID: PMC7182254 DOI: 10.1371/journal.pone.0231778] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2019] [Accepted: 04/01/2020] [Indexed: 12/22/2022] Open
Abstract
Air pollution with PM2.5 (particulate matter smaller than 2.5 micro-metres in diameter) is a major health hazard in many cities worldwide, but since measuring instruments have traditionally been expensive, monitoring sites are rare and generally show only background concentrations. With the advent of low-cost, wirelessly connected sensors, air quality measurements are increasingly being made in places where many people spend time and pollution is much worse: on streets near traffic. In the interests of enabling members of the public to measure the air that they breathe, we took an open-source approach to designing a device for measuring PM2.5. Parts are relatively cheap, but of good quality and can be easily found in electronics or hardware stores, or on-line. Software is open source and the free LoRaWAN-based "The Things Network" the platform. A number of low-cost sensors we tested had problems, but those selected performed well when co-located with reference-quality instruments. A network of the devices was deployed in an urban centre, yielding valuable data for an extended time. Concentrations of PM2.5 at street level were often ten times worse than at air quality stations. The devices and network offer the opportunity for measurements in locations that concern the public.
Collapse
Affiliation(s)
- Hugh Forehead
- SMART Infrastructure Facility, University of Wollongong, Wollongong, Australia
- Clean Air and Urban Landscapes (CAUL) hub, Melbourne, Victoria, Australia
| | - Johan Barthelemy
- SMART Infrastructure Facility, University of Wollongong, Wollongong, Australia
| | - Bilal Arshad
- SMART Infrastructure Facility, University of Wollongong, Wollongong, Australia
| | - Nicolas Verstaevel
- SMART Infrastructure Facility, University of Wollongong, Wollongong, Australia
- Université Toulouse 1 Capitole, Institut de Recherche en Informatique de Toulouse (IRIT), Toulouse, France
| | - Owen Price
- Centre for Sustainable Ecosystem Solutions, University of Wollongong, Wollongong, Australia
| | - Pascal Perez
- SMART Infrastructure Facility, University of Wollongong, Wollongong, Australia
- Clean Air and Urban Landscapes (CAUL) hub, Melbourne, Victoria, Australia
| |
Collapse
|
27
|
Hendryx M, Wang S, Romanak KA, Salamova A, Venier M. Personal exposure to polycyclic aromatic hydrocarbons in Appalachian mining communities. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2020; 257:113501. [PMID: 31706774 PMCID: PMC6981027 DOI: 10.1016/j.envpol.2019.113501] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/30/2019] [Revised: 10/25/2019] [Accepted: 10/26/2019] [Indexed: 05/07/2023]
Abstract
Coal mining activities may increase residential exposure to polycyclic aromatic hydrocarbons (PAHs), but personal PAH exposures have not been studied in mining areas. We used silicone wristbands as passive personal samplers to estimate PAH exposures in coal mining communities in Central Appalachia in the United States. Adults (N = 101) wore wristbands for one week; 51 resided in communities within approximately three miles of surface mining sites, and 50 resided 10 or more miles from mining sites. Passive indoor polyurethane foam (PUF) sampling was conducted in residents' homes, and a sample of 16 outdoor PUF samples were also collected. Nine PAH congeners were commonly detected in wristbands (mean ± standard deviation), including phenanthrene (50.2 ± 68.7 ng/g), benz[a]anthracene (20.2 ± 58.2 ng/g), fluoranthene (19.4 ± 24.1 ng/g) and pyrene (15.2 ± 18.2 ng/g). Controlling for participant characteristics and season, participants living closer to mining sites had significantly higher levels of phenanthrene, fluorene, fluoranthene, pyrene and ∑PAHs in wristbands compared to participants living farther from mining. Indoor air showed no significant group differences except for pyrene, but outdoor air showed significant or marginally significant differences for phenanthrene, fluorene, pyrene and ∑PAHs. The results suggest that mining community residents face exposure to outdoor mining-related pollutants, and demonstrate that personal silicone wristbands can be deployed as effective passive sampling devices.
Collapse
Affiliation(s)
- Michael Hendryx
- Department of Environmental and Occupational Health, School of Public Health, Indiana University, 1025 E, 7th St., Bloomington, USA.
| | - Shaorui Wang
- O'Neill School of Public and Environmental Affairs, Indiana University, Bloomington, IN, 47405, USA
| | - Kevin A Romanak
- O'Neill School of Public and Environmental Affairs, Indiana University, Bloomington, IN, 47405, USA
| | - Amina Salamova
- O'Neill School of Public and Environmental Affairs, Indiana University, Bloomington, IN, 47405, USA
| | - Marta Venier
- O'Neill School of Public and Environmental Affairs, Indiana University, Bloomington, IN, 47405, USA
| |
Collapse
|
28
|
Afshar-Mohajer N, Foos R, Volckens J, Ramachandran G. Variability of aerosol mass and number concentrations during taconite mining operations. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2020; 17:1-14. [PMID: 31800373 DOI: 10.1080/15459624.2019.1688823] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
This study characterized concentration metrics of airborne nanoparticles and their time series across major operations of a taconite mine through monitoring respirable and ultrafine particle concentrations at four major processing departments of the mine: crushing, dry milling, wet milling, and pelletizing (United Taconite Mine, Iron Junction, MN, USA). We used three area stations of direct-reading instruments to estimate concentration metrics including PM1 (particles with an aerodynamic diameter <1 µm), respirable dust (particles sampled according to the respirable convention with a 50% sampling efficiency at an aerodynamic diameter of 4 µm), PN (total number concentration of particles), and lung-deposited surface area concentrations (LDSA) of particles smaller than 300 nm, on two different days. Results for each station were compared using bivariate correlation analysis to obtain insight into the spatial distribution, and intra-class correlation coefficients (ICCs) to evaluate the between-day repeatability between the measurements. Comparability of the LDSA concentrations measured by two different devices was also investigated using linear regression. Results revealed that the pelletizing operation produced the highest average LDSA concentration on both days (with a maximum concentration of 199 ± 48 µm2/cm3 in pelletizing, 141 ± 52 µm2/cm3 in crushing, 91 ± 9 µm2/cm3 in dry milling, and 85 ± 7 µm2/cm3 in wet milling). Concentrations in all operations showed a fair to excellent between-day repeatability but they were significantly different within stations of each operation. Measured LDSA concentrations did not show a linear correlation between different instruments, except for crushing.
Collapse
Affiliation(s)
- Nima Afshar-Mohajer
- Department of Environmental Health and Engineering, Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland, USA
| | - Rebecca Foos
- Department of Mechanical Engineering, Colorado State University, Fort Collins, Colorado, USA
| | - John Volckens
- Department of Mechanical Engineering, Colorado State University, Fort Collins, Colorado, USA
| | - Gurumurthy Ramachandran
- Department of Environmental Health and Engineering, Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland, USA
| |
Collapse
|
29
|
Giechaskiel B, Mamakos A, Woodburn J, Szczotka A, Bielaczyc P. Evaluation of a 10 nm Particle Number Portable Emissions Measurement System (PEMS). SENSORS 2019; 19:s19245531. [PMID: 31847386 PMCID: PMC6960637 DOI: 10.3390/s19245531] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/23/2019] [Revised: 12/03/2019] [Accepted: 12/12/2019] [Indexed: 01/12/2023]
Abstract
On-board portable emissions measurement systems (PEMS) are part of the type approval, in-service conformity, and market surveillance aspects of the European exhaust emissions regulation. Currently, only solid particles >23 nm are counted, but Europe will introduce a lower limit of 10 nm. In this study, we evaluated a 10-nm prototype portable system comparing it with laboratory systems measuring diesel, gasoline, and CNG (compressed natural gas) vehicles with emission levels ranging from approximately 2 × 1010 to 2 × 1012 #/km. The results showed that the on-board system differed from the laboratory 10-nm system on average for the tested driving cycles by less than approximately 10% at levels below 6 × 1011 #/km and by approximately 20% for high-emitting vehicles. The observed differences were similar to those observed in the evaluation of portable >23 nm particle counting systems, despite the relatively small size of the emitted particles (with geometric mean diameters <42 nm) and the additional challenges associated with sub-23 nm measurements. The latter included the presence of semivolatile sub-23 nm particles, the elevated concentration levels during cold start, and also the formation of sub-23 nm artefacts from the elastomers that are used to connect the tailpipe to the measurement devices. The main conclusion of the study is that >10 nm on-board systems can be ready for introduction in future regulations.
Collapse
Affiliation(s)
- Barouch Giechaskiel
- European Commission, Joint Research Centre, 21027 Ispra, Italy
- Correspondence: ; Tel.: +39-0332-78-5312
| | | | - Joseph Woodburn
- BOSMAL Automotive R&D Institute Ltd., 43300 Bielsko-Biala, Poland; (J.W.); (A.S.); (P.B.)
| | - Andrzej Szczotka
- BOSMAL Automotive R&D Institute Ltd., 43300 Bielsko-Biala, Poland; (J.W.); (A.S.); (P.B.)
| | - Piotr Bielaczyc
- BOSMAL Automotive R&D Institute Ltd., 43300 Bielsko-Biala, Poland; (J.W.); (A.S.); (P.B.)
| |
Collapse
|
30
|
Giechaskiel B, Bonnel P, Perujo A, Dilara P. Solid Particle Number (SPN) Portable Emissions Measurement Systems (PEMS) in the European Legislation: A Review. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2019; 16:ijerph16234819. [PMID: 31801216 PMCID: PMC6926649 DOI: 10.3390/ijerph16234819] [Citation(s) in RCA: 38] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/04/2019] [Revised: 11/27/2019] [Accepted: 11/29/2019] [Indexed: 11/16/2022]
Abstract
Portable emissions measurement systems (PEMS) for gaseous pollutants were firstly introduced in the United States regulation to check the in-use compliance of heavy-duty engines, avoiding the high costs of removing the engine and testing it on a dynamometer in the laboratory. In Europe, the in-service conformity of heavy-duty engines has been checked with PEMS for gaseous pollutants since 2014. To strengthen emissions regulations with a view to minimise the differences between on-road and laboratory emission levels in some cases, PEMS testing, including solid particle number (SPN), was introduced for the type-approval of light-duty vehicles in Europe in 2017 and for in-service conformity in 2019. SPN-PEMS for heavy-duty engines will be introduced in 2021. This paper gives an overview of the studies for SPN-PEMS from early 2013 with the first prototypes until the latest testing and improvements in 2019. The first prototype diffusion charger (DC) based systems had high differences from the reference laboratory systems at the first light-duty vehicles campaign. Tightening of the technical requirements and improvements from the instrument manufacturers resulted in differences of around 50%. Similar differences were found in an inter-laboratory comparison exercise with the best performing DC- and CPC- (condensation particle counter) based system. The heavy-duty evaluation phase at a single lab and later at various European laboratories revealed higher differences due to the small size of the urea generated particles and their high charge at elevated temperatures. This issue, along with robustness at low ambient temperatures, was addressed by the instrument manufacturers bringing the measurement uncertainty to the 50% levels. This measurement uncertainty needs to be considered at the on-road emission results measured with PEMS.
Collapse
Affiliation(s)
- Barouch Giechaskiel
- European Commission, Joint Research Centre, 21027 Ispra, Italy; (P.B.); (A.P.)
- Correspondence: ; Tel.: +39-0332-785312
| | - Pierre Bonnel
- European Commission, Joint Research Centre, 21027 Ispra, Italy; (P.B.); (A.P.)
| | - Adolfo Perujo
- European Commission, Joint Research Centre, 21027 Ispra, Italy; (P.B.); (A.P.)
| | | |
Collapse
|
31
|
Gonzalez-Pech NI, Stebounova LV, Ustunol IB, Park JH, Anthony TR, Peters TM, Grassian VH. Size, composition, morphology, and health implications of airborne incidental metal-containing nanoparticles. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2019; 16:387-399. [PMID: 30570411 PMCID: PMC7086472 DOI: 10.1080/15459624.2018.1559925] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
There is great concern regarding the adverse health implications of engineered nanoparticles. However, there are many circumstances where the production of incidental nanoparticles, i.e., nanoparticles unintentionally generated as a side product of some anthropogenic process, is of even greater concern. In this study, metal-based incidental nanoparticles were measured in two occupational settings: a machining center and a foundry. On-site characterization of substrate-deposited incidental nanoparticles using a field-portable X-ray fluorescence provided some insights into the chemical characteristics of these metal-containing particles. The same substrates were then used to carry out further off-site analysis including single-particle analysis using scanning electron microscopy and energy-dispersive X-ray spectroscopy. Between the two sites, there were similarities in the size and composition of the incidental nanoparticles as well as in the agglomeration and coagulation behavior of nanoparticles. In particular, incidental nanoparticles were identified in two forms: submicrometer fractal-like agglomerates from activities such as welding and supermicrometer particles with incidental nanoparticles coagulated to their surface, herein referenced as nanoparticle collectors. These agglomerates will affect deposition and transport inside the respiratory system of the respirable incidental nanoparticles and the corresponding health implications. The studies of incidental nanoparticles generated in occupational settings lay the groundwork on which occupational health and safety protocols should be built.
Collapse
Affiliation(s)
| | - Larissa V. Stebounova
- Department of Occupational and Environmental Health, The University of Iowa, Iowa City, IA
| | - Irem B. Ustunol
- Department of Nanoengineering, University of California San Diego, La Jolla, CA
| | - Jae Hong Park
- School of Health Sciences, Purdue University, West Lafayette, IN
| | - T. Renee Anthony
- Department of Occupational and Environmental Health, The University of Iowa, Iowa City, IA
| | - Thomas M. Peters
- Department of Occupational and Environmental Health, The University of Iowa, Iowa City, IA
| | - Vicki H. Grassian
- Department of Chemistry and Biochemistry, University of California San Diego, La Jolla, CA
- Department of Nanoengineering, University of California San Diego, La Jolla, CA
- Scripps Institution of Oceanography, University of California San Diego, La Jolla, CA
| |
Collapse
|
32
|
Depleted uranium induces human carcinogenesis involving the immune and chaperoning systems: Realities and working hypotheses. Med Hypotheses 2019; 124:26-30. [PMID: 30798910 DOI: 10.1016/j.mehy.2019.01.018] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2018] [Revised: 01/13/2019] [Accepted: 01/23/2019] [Indexed: 02/06/2023]
Abstract
Cancer is caused by a combination of factors, genetic, epigenetics and environmental. Among the latter, environmental pollutants absorbed by contact, inhalation, or ingestion are major proven or suspected culprits. Depleted uranium (DU) is one of them directly pertinent to the military and civilians working in militarized areas. It is considered a weak carcinogen but its implication in cancer development in exposed individuals is supported by various data. Since not all subjects exposed to DU develop cancer, it is likely that DU-dependent carcinogenesis requires cofactors, such as genetic predisposition and deficiencies of the chaperoning and immune systems. It is of the essence to adopt every possible protective measure as well as performing careful screening for early diagnosis to protect the military that work in war areas in which weapons with DU are, or have been, used. These topics are discussed here, along with a proposed working hypothesis for investigating the pathophysiology of DU-related carcinogenesis, including the possible role of the chaperoning system.
Collapse
|
33
|
Schulte P, Leso V, Niang M, Iavicoli I. Biological monitoring of workers exposed to engineered nanomaterials. Toxicol Lett 2018; 298:112-124. [PMID: 29920308 PMCID: PMC6239923 DOI: 10.1016/j.toxlet.2018.06.003] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2018] [Revised: 05/29/2018] [Accepted: 06/08/2018] [Indexed: 12/27/2022]
Abstract
As the number of nanomaterial workers increase there is need to consider whether biomonitoring of exposure should be used as a routine risk management tool. Currently, no biomonitoring of nanomaterials is mandated by authoritative or regulatory agencies. However, there is a growing knowledge base to support such biomonitoring, but further research is needed as are investigations of priorities for biomonitoring. That research should be focused on validation of biomarkers of exposure and effect. Some biomarkers of effect are generally nonspecific. These biomarkers need further interpretation before they should be used. Overall biomonitoring of nanomaterial workers may be important to supplement risk assessment and risk management efforts.
Collapse
Affiliation(s)
- P Schulte
- National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, 1090 Tusculum Avenue, MS C-14, Cincinnati, OH 45226, USA.
| | - V Leso
- Department of Public Health, University of Naples Federico II, Via S. Pansini 5, 80131 Naples, Italy
| | - M Niang
- University of Cincinnati, Cincinnati, OH, USA
| | - I Iavicoli
- Department of Public Health, University of Naples Federico II, Via S. Pansini 5, 80131 Naples, Italy
| |
Collapse
|
34
|
Assimakopoulos VD, Bekiari T, Pateraki S, Maggos T, Stamatis P, Nicolopoulou P, Assimakopoulos MN. Assessing personal exposure to PM using data from an integrated indoor-outdoor experiment in Athens-Greece. THE SCIENCE OF THE TOTAL ENVIRONMENT 2018; 636:1303-1320. [PMID: 29913592 DOI: 10.1016/j.scitotenv.2018.04.249] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/26/2017] [Revised: 04/03/2018] [Accepted: 04/18/2018] [Indexed: 06/08/2023]
Abstract
An integrated indoor-outdoor 15-day PM sampling campaign in a general area close to the centre of Athens, targeted to examine personal exposure. All microenvironments (MEs) (second and fourth floor flats, cafes, cars, restaurants, underground metro, outdoor etc.) frequented by the residents were included in the study. The instrumentation used was both stationary (low volume samplers) and portable/wearable to be able to measure continuously PM10, PM2.5, PM1 and analyze chemically PM2.5 and PM1 samples. The study showed that the residences' air quality was determined by the type and intensity of outdoor sources and their vertical distance from the street. Indoor activities such as cooking, cleaning further increased PM levels and formulated the air quality, while particulate accumulation was evident. In general, PM2.5 concentrations were higher outdoors, 11-43 μg/m3, than in the second floor flat as well as on days within different MEs, 13-33 μg/m3 and 8-35 μg/m3, respectively and finally in the fourth floor 10-18 μg/m3. PM2.5 chemical composition was typical of a Mediterranean urban area predominantly composed on average of OC/EC (33%), sulfate (13%), ammonium (9%), nitrate (5%) and crustal material (Cl-, Na+, K+, Mg2+ and Ca2+) (5%). On days when other MEs were visited crustal material increased on average to 16%. The PM levels measured with the portable instrumentation at all mEs showed that the persons were exposed to higher PM10 concentrations in the subway (avg. 218 μg/m3) due to the resuspension of crustal material, while maximum PM2.5 and PM1 were experienced in cafes where smoking was allowed (avg. 126 and 108 μg/m3, respectively). Using the car resulted to the lowest PM10, PM2.5 and PM1 exposure (58, 10 and 6 μg/m3, respectively). Total exposure to particulates depended both on the time spent in each ME and on the mixture of MEs visited in 24 h.
Collapse
Affiliation(s)
- V D Assimakopoulos
- Institute for Environmental Research and Suitable Development, National Observatory of Athens, 15236 P. Penteli, Greece.
| | - T Bekiari
- Pathology Department, University of Athens, Medical School, Athens, Greece
| | - S Pateraki
- Environmental Research Laboratory/INT-RP, National Center for Scientific Research "DEMOKRITOS", 153 10, Aghia Paraskevi Attikis, Athens, Greece
| | - Th Maggos
- Environmental Research Laboratory/INT-RP, National Center for Scientific Research "DEMOKRITOS", 153 10, Aghia Paraskevi Attikis, Athens, Greece
| | - P Stamatis
- Pathology Department, University of Athens, Medical School, Athens, Greece
| | - P Nicolopoulou
- Pathology Department, University of Athens, Medical School, Athens, Greece
| | - M N Assimakopoulos
- Department of Environmental Physics-Meteorology, Faculty of Physics, University of Athens, University Campus, 15784 Athens, Greece
| |
Collapse
|
35
|
Koivisto AJ, Kling KI, Fonseca AS, Bluhme AB, Moreman M, Yu M, Costa AL, Giovanni B, Ortelli S, Fransman W, Vogel U, Jensen KA. Dip coating of air purifier ceramic honeycombs with photocatalytic TiO 2 nanoparticles: A case study for occupational exposure. THE SCIENCE OF THE TOTAL ENVIRONMENT 2018; 630:1283-1291. [PMID: 29554749 DOI: 10.1016/j.scitotenv.2018.02.316] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/19/2018] [Revised: 02/26/2018] [Accepted: 02/26/2018] [Indexed: 06/08/2023]
Abstract
Nanoscale TiO2 (nTiO2) is manufactured in high volumes and is of potential concern in occupational health. Here, we measured workers exposure levels while ceramic honeycombs were dip coated with liquid photoactive nanoparticle suspension and dried with an air blade. The measured nTiO2 concentration levels were used to assess process specific emission rates using a convolution theorem and to calculate inhalation dose rates of deposited nTiO2 particles. Dip coating did not result in detectable release of particles but air blade drying released fine-sized TiO2 and nTiO2 particles. nTiO2 was found in pure nTiO2 agglomerates and as individual particles deposited onto background particles. Total particle emission rates were 420×109min-1, 1.33×109μm2min-1, and 3.5mgmin-1 respirable mass. During a continued repeated process, the average exposure level was 2.5×104cm-3, 30.3μm2cm-3, <116μgm-3 for particulate matter. The TiO2 average exposure level was 4.2μgm-3, which is well below the maximum recommended exposure limit of 300μgm-3 for nTiO2 proposed by the US National Institute for Occupational Safety and Health. During an 8-hour exposure, the observed concentrations would result in a lung deposited surface area of 4.3×10-3cm2g-1 of lung tissue and 13μg of TiO2 to the trachea-bronchi, and alveolar regions. The dose levels were well below the one hundredth of the no observed effect level (NOEL1/100) of 0.11cm2g-1 for granular biodurable particles and a daily no significant risk dose level of 44μgday-1. These emission rates can be used in a mass flow model to predict the impact of process emissions on personal and environmental exposure levels.
Collapse
Affiliation(s)
- Antti Joonas Koivisto
- National Research Centre for the Working Environment, Lersø Parkallé 105, Copenhagen DK-2100, Denmark.
| | - Kirsten Inga Kling
- National Research Centre for the Working Environment, Lersø Parkallé 105, Copenhagen DK-2100, Denmark
| | - Ana Sofia Fonseca
- National Research Centre for the Working Environment, Lersø Parkallé 105, Copenhagen DK-2100, Denmark
| | - Anders Brostrøm Bluhme
- National Research Centre for the Working Environment, Lersø Parkallé 105, Copenhagen DK-2100, Denmark; Technical University of Denmark, Department of Micro- and Nanotechnology, Ørsteds Plads, Building 345B, DK-2800 Kgs. Lyngby, Denmark
| | | | - Mingzhou Yu
- China Jiliang University, Hangzhou, China; Key Laboratory of Aerosol Chemistry and Physics, Chinese Academy of Science, Xi'an, China
| | | | - Baldi Giovanni
- COLOROBBIA CONSULTING S.r.L., Via Pietramarina 53, 50053, Sovigliana, Vinci, FI, Italy
| | | | | | - Ulla Vogel
- National Research Centre for the Working Environment, Lersø Parkallé 105, Copenhagen DK-2100, Denmark
| | - Keld Alstrup Jensen
- National Research Centre for the Working Environment, Lersø Parkallé 105, Copenhagen DK-2100, Denmark
| |
Collapse
|
36
|
Stebounova LV, Gonzalez-Pech NI, Park JH, Anthony TR, Grassian VH, Peters TM. Particle Concentrations in Occupational Settings Measured with a Nanoparticle Respiratory Deposition (NRD) Sampler. Ann Work Expo Health 2018; 62:699-710. [PMID: 29788211 PMCID: PMC6775226 DOI: 10.1093/annweh/wxy033] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2017] [Revised: 03/16/2018] [Accepted: 04/30/2018] [Indexed: 11/14/2022] Open
Abstract
There is an increasing need to evaluate concentrations of nanoparticles in occupational settings due to their potential negative health effects. The Nanoparticle Respiratory Deposition (NRD) personal sampler was developed to collect nanoparticles separately from larger particles in the breathing zone of workers, while simultaneously providing a measure of respirable mass concentration. This study compared concentrations measured with the NRD sampler to those measured with a nano Micro Orifice Uniform-Deposit Impactor (nanoMOUDI) and respirable samplers in three workplaces. The NRD sampler performed well at two out of three locations, where over 90% of metal particles by mass were submicrometer particle size (a heavy vehicle machining and assembly facility and a shooting range). At the heavy vehicle facility, the mean metal mass concentration of particles collected on the diffusion stage of the NRD was 42.5 ± 10.0 µg/m3, within 5% of the nanoMOUDI concentration of 44.4 ± 7.4 µg/m3. At the shooting range, the mass concentration for the diffusion stage of the NRD was 5.9 µg/m3, 28% above the nanoMOUDI concentration of 4.6 µg/m3. In contrast, less favorable results were obtained at an iron foundry, where 95% of metal particles by mass were larger than 1 µm. The accuracy of nanoparticle collection by NRD diffusion stage may have been compromised by high concentrations of coarse particles at the iron foundry, where the NRD collected almost 5-fold more nanoparticle mass compared to the nanoMOUDI on one sampling day and was more than 40% different on other sampling days. The respirable concentrations measured by NRD samplers agreed well with concentrations measured by respirable samplers at all sampling locations. Overall, the NRD sampler accurately measured concentrations of nanoparticles in industrial environments when concentrations of large, coarse mode, particles were low.
Collapse
Affiliation(s)
- Larissa V Stebounova
- Department of Occupational and Environmental Health, The University of Iowa, Iowa City, IA, USA
| | - Natalia I Gonzalez-Pech
- Department of Chemistry and Biochemistry, University of California San Diego, La Jolla, CA, USA
| | - Jae Hong Park
- School of Health Sciences, Purdue University, West Lafayette, IN, USA
| | - T Renee Anthony
- Department of Occupational and Environmental Health, The University of Iowa, Iowa City, IA, USA
| | - Vicki H Grassian
- Department of Chemistry and Biochemistry, University of California San Diego, La Jolla, CA, USA
- Department of Nanoengineering, Scripps Institution of Oceanography, University of California, La Jolla, CA, USA
| | - Thomas M Peters
- Department of Occupational and Environmental Health, The University of Iowa, Iowa City, IA, USA
| |
Collapse
|
37
|
Iavicoli I, Fontana L, Pingue P, Todea AM, Asbach C. Assessment of occupational exposure to engineered nanomaterials in research laboratories using personal monitors. THE SCIENCE OF THE TOTAL ENVIRONMENT 2018; 627:689-702. [PMID: 29426194 DOI: 10.1016/j.scitotenv.2018.01.260] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/04/2017] [Revised: 01/25/2018] [Accepted: 01/25/2018] [Indexed: 05/21/2023]
Abstract
Exposure assessment is a key stage in the risk assessment/management of engineered nanomaterials. Although different sampling strategies and instruments have been used to define the occupational exposure to nano-scale materials, currently there is no international consensus regarding measurement strategy, metrics and limit values. In fact, the assessment of individual exposure to engineered nanomaterials remains a critical issue despite recent innovative developments in personal monitors and samplers. Hence, we used several of these instruments to evaluate the workers' personal exposure in a large research laboratory where engineered nanomaterials are produced, handled, and characterized in order to provide input data for nanomaterial exposure assessment strategies and future epidemiological studies. The results obtained using personal monitors showed that the workplace concentrations of engineered nanomaterials (lung deposited surface area and particle number concentrations) were quite low in all the different workplaces monitored, with short spikes during the execution of some specific job tasks. The sampling strategy was been adopted on the basis of an Organisation for Economic Cooperation and Development (OECD) suggestion for a tiered approach and was found to be suitable for determining the individual exposure and for identifying possible sources of emission, even those with very low emission rates. The use of these instruments may lead to a significant improvement not only in the exposure assessment stage but, more generally, in the entire risk assessment and management process.
Collapse
Affiliation(s)
- Ivo Iavicoli
- Section of Occupational Medicine, Department of Public Health, University of Naples "Federico II", Via S. Pansini 5, 80131 Naples, Italy; Institute of Public Health, Catholic University of Sacred Health, Largo F. Vito 1, 00168 Rome, Italy.
| | - Luca Fontana
- Institute of Public Health, Catholic University of Sacred Health, Largo F. Vito 1, 00168 Rome, Italy
| | - Pasqualantonio Pingue
- Laboratory of National Enterprise for nanoScience and nanoTechnology (NEST), Scuola Normale Superiore, Piazza S. Silvestro 12, 56127 Pisa, Italy.
| | - Ana Maria Todea
- Institut für Energie- und Umwelttechnik e. V. (IUTA), Air Quality & Filtration, 47229 Duisburg, Germany
| | - Christof Asbach
- Institut für Energie- und Umwelttechnik e. V. (IUTA), Air Quality & Filtration, 47229 Duisburg, Germany.
| |
Collapse
|
38
|
Bau S, Payet R, Toussaint A, Witschger O, Todea AM, Monz C, Asbach C. Combining NSAM and CPC concentrations to determine airborne nanoparticle count median diameter: Application to various laboratory and workplace aerosols. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2018; 15:492-501. [PMID: 29580178 DOI: 10.1080/15459624.2018.1449953] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Because nanomaterials have been increasingly developed and used in many technology and industry sectors over the last 20 years, an increasing number of workers is likely to be exposed to airborne nanoparticles. In addition, the question of the nanomaterial characteristics that should be assessed in epidemiological studies remains open. Thus, assessing occupational exposure to airborne nanoparticles will not only rely on mass concentration and chemical composition. Rather, key parameters, such as particle size, have to be included in measurement strategies. We previously proposed a methodology to estimate the Count Median Diameter (CMD) of an aerosol based on the simultaneous size-integrated measurement of two particle concentrations, lung-deposited surface area, and number, thanks to field-portable, commercially available aerosol instruments (Nanoparticle Surface Area Monitor/Condensation Particle Counter combination). In addition to previous work, this study investigates the case of various polydisperse metal oxides, organic oil, and salt particles with CMDs ranging from 16-410 nm. Once corrected, the CMDs derived from the NSAM/CPC agree within ±20% with regard to the reference electrical mobility equivalent diameter, regardless of aerosol composition, morphology, or geometric standard deviation (GSD). Furthermore, the field-applicability of the method was tested through 6 sets of experimental data stemming from workplace measurement campaigns where different materials were produced and handled (TiO2, SiO2, Ag, Multi-Walled Carbon Nanotubes-MWCNT), covering a range of CMDs between 40 and 190 nm. All situations considered, the approach based on the combination of a NSAM and a CPC leads to a satisfying estimation of particle CMD, within ±20% compared to reference CMD.
Collapse
Affiliation(s)
- S Bau
- a Institut National de Recherche et de Sécurité, Laboratoire de Métrologie des Aérosols , Vandoeuvre , France
| | - R Payet
- a Institut National de Recherche et de Sécurité, Laboratoire de Métrologie des Aérosols , Vandoeuvre , France
| | - A Toussaint
- a Institut National de Recherche et de Sécurité, Laboratoire de Métrologie des Aérosols , Vandoeuvre , France
| | - O Witschger
- a Institut National de Recherche et de Sécurité, Laboratoire de Métrologie des Aérosols , Vandoeuvre , France
| | - A M Todea
- b Institut für Energie und Umwelttechnik e. V. (IUTA) , Duisburg , Germany
| | - C Monz
- c Institut für Gefahrstoffforschung (IGF) , Bochum , Germany
| | - C Asbach
- b Institut für Energie und Umwelttechnik e. V. (IUTA) , Duisburg , Germany
| |
Collapse
|
39
|
Valentini F, Mari E, Zicari A, Calcaterra A, Talamo M, Scioli MG, Orlandi A, Mardente S. Metal Free Graphene Oxide (GO) Nanosheets and Pristine-Single Wall Carbon Nanotubes (p-SWCNTs) Biocompatibility Investigation: A Comparative Study in Different Human Cell Lines. Int J Mol Sci 2018; 19:ijms19051316. [PMID: 29710799 PMCID: PMC5983736 DOI: 10.3390/ijms19051316] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2018] [Revised: 04/21/2018] [Accepted: 04/23/2018] [Indexed: 02/07/2023] Open
Abstract
The in vitro biocompatibility of Graphene Oxide (GO) nanosheets, which were obtained by the electrochemical exfoliation of graphite electrodes in an electrolytic bath containing salts, was compared with the pristine Single Wall Carbon Nanotubes (p-SWCNTs) under the same experimental conditions in different human cell lines. The cells were treated with different concentrations of GO and SWCNTs for up to 48 h. GO did not induce any significant morphological or functional modifications (demonstrating a high biocompatibility), while SWNCTs were toxic at any concentration used after a few hours of treatment. The cell viability or cytotoxicity were detected by the trypan blue assay and the lactate dehydrogenase LDH quantitative enzymatic test. The Confocal Laser Scanning Microscopy (CLSM) and transmission electron microscopy (TEM) analysis demonstrated the uptake and internalization of GO sheets into cells, which was localized mainly in the cytoplasm. Different results were observed in the same cell lines treated with p-SWCNTs. TEM and CLSM (Confocal Laser Scanning Microscopy) showed that the p-SWCNTs induced vacuolization in the cytoplasm, disruption of cellular architecture and damage to the nuclei. The most important result of this study is our finding of a higher GO biocompatibility compared to the p-SWCNTs in the same cell lines. This means that GO nanosheets, which are obtained by the electrochemical exfoliation of a graphite-based electrode (carried out in saline solutions or other physiological working media) could represent an eligible nanocarrier for drug delivery, gene transfection and molecular cell imaging tests.
Collapse
Affiliation(s)
- Federica Valentini
- Department of Sciences and Chemical Technologies, University of Rome Tor Vergata, via della Ricerca Scientifica 1, 00133 Rome, Italy.
- INUIT Foundation, University of Roma Tor Vergata, via dell'Archigginasio, 00133 Rome, Italy.
| | - Emanuela Mari
- Department of Experimental Medicine, University of Rome Sapienza, Viale Regina Elena 324, 00161 Rome, Italy.
| | - Alessandra Zicari
- Department of Experimental Medicine, University of Rome Sapienza, Viale Regina Elena 324, 00161 Rome, Italy.
| | - Andrea Calcaterra
- INUIT Foundation, University of Roma Tor Vergata, via dell'Archigginasio, 00133 Rome, Italy.
| | - Maurizio Talamo
- INUIT Foundation, University of Roma Tor Vergata, via dell'Archigginasio, 00133 Rome, Italy.
| | - Maria Giovanna Scioli
- Department of Medicine, Pathological Anatomy, University of Rome Tor Vergata, Viale Oxford 81, 00133 Rome, Italy.
| | - Augusto Orlandi
- Department of Medicine, Pathological Anatomy, University of Rome Tor Vergata, Viale Oxford 81, 00133 Rome, Italy.
| | - Stefania Mardente
- Department of Experimental Medicine, University of Rome Sapienza, Viale Regina Elena 324, 00161 Rome, Italy.
| |
Collapse
|
40
|
Du W, Shen G, Chen Y, Zhuo S, Xu Y, Li X, Pan X, Cheng H, Wang X, Tao S. Wintertime pollution level, size distribution and personal daily exposure to particulate matters in the northern and southern rural Chinese homes and variation in different household fuels. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2017; 231:497-508. [PMID: 28841502 DOI: 10.1016/j.envpol.2017.08.039] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/21/2017] [Revised: 08/03/2017] [Accepted: 08/11/2017] [Indexed: 06/07/2023]
Abstract
This study investigated and compared wintertime air pollution and personal exposure in the rural northern and southern Chinese homes. Daily indoor and outdoor particle samples were simultaneously collected by using stationary samplers, and personal exposure was directly measured using portable carried samplers. The daily average concentrations of indoor and outdoor PM2.5 were 521 ± 234 and 365 ± 185 μg/m3 in the northern village, that were about 2.3-2.7 times of 188 ± 104 and 150 ± 29 μg/m3 in indoor and outdoor air in the southern villages. Particle size distribution was similar between indoor and outdoor air, and had relatively smaller difference between the two sites, relative to the particle mass concentration difference. PM2.5 contributed to ∼80% of the TSP mass, and in PM2.5, near 90% were PM1.0. In homes using electricity in the southern villages, outdoor air pollution could explain 70-80% of the variation in indoor air pollution. The daily exposure to PM2.5 measured using personal carried samplers were 451 ± 301 μg/m3 in the northern villages with traditional solid fuels used for daily cooking and heating, and in the southern villages without heating, the exposure to PM2.5 were 184 ± 83 and 166 ± 45 μg/m3, respectively, for the population using wood and electricity for daily cooking. Time-weighted daily average exposure estimated from area concentration and time spent indoor and outdoor was generally correlated the directly measured exposure.
Collapse
Affiliation(s)
- Wei Du
- Laboratory of Earth Surface Processes, College of Urban and Environmental Sciences, Peking University, Beijing, 100871, China
| | - Guofeng Shen
- Laboratory of Earth Surface Processes, College of Urban and Environmental Sciences, Peking University, Beijing, 100871, China.
| | - Yuanchen Chen
- College of Environment, Research Centre of Environmental Science, Zhejiang University of Technology, Hangzhou, 310032, China
| | - Shaojie Zhuo
- Laboratory of Earth Surface Processes, College of Urban and Environmental Sciences, Peking University, Beijing, 100871, China
| | - Yang Xu
- Laboratory of Earth Surface Processes, College of Urban and Environmental Sciences, Peking University, Beijing, 100871, China
| | - Xinyue Li
- Laboratory of Earth Surface Processes, College of Urban and Environmental Sciences, Peking University, Beijing, 100871, China
| | - Xuelian Pan
- Laboratory of Earth Surface Processes, College of Urban and Environmental Sciences, Peking University, Beijing, 100871, China
| | - Hefa Cheng
- Laboratory of Earth Surface Processes, College of Urban and Environmental Sciences, Peking University, Beijing, 100871, China
| | - Xilong Wang
- Laboratory of Earth Surface Processes, College of Urban and Environmental Sciences, Peking University, Beijing, 100871, China
| | - Shu Tao
- Laboratory of Earth Surface Processes, College of Urban and Environmental Sciences, Peking University, Beijing, 100871, China.
| |
Collapse
|