1
|
Dias M, Gomes B, Pena P, Cervantes R, Beswick A, Duchaine C, Kolk A, Madsen AM, Oppliger A, Pogner C, Duquenne P, Wouters IM, Crook B, Viegas C. Filling the knowledge gap: Scoping review regarding sampling methods, assays, and further requirements to assess airborne viruses. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 946:174016. [PMID: 38908595 DOI: 10.1016/j.scitotenv.2024.174016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/12/2024] [Revised: 06/12/2024] [Accepted: 06/13/2024] [Indexed: 06/24/2024]
Abstract
Assessment of occupational exposure to viruses is crucial to identify virus reservoirs and sources of dissemination at an early stage and to help prevent spread between employees and to the general population. Measuring workers' exposure can facilitate assessment of the effectiveness of protective and mitigation measures in place. The aim of this scoping review is to give an overview of available methods and those already implemented for airborne virus' exposure assessment in different occupational and indoor environments. The results retrieved from the different studies may contribute to the setting of future standards and guidelines to ensure a reliable risk characterization in the occupational environments crucial for the implementation of effective control measures. The search aimed at selecting studies between January 1st 2010 and June 30th 2023 in the selected databases. Fifty papers on virus exposure assessment fitted the eligibility criteria and were selected for data extraction. Overall, this study identified gaps in knowledge regarding virus assessment and pinpointed the needs for further research. Several discrepancies were found (transport temperatures, elution steps, …), as well as a lack of publication of important data related to the exposure conditions (contextual information). With the available information, it is impossible to compare results between studies employing different methods, and even if the same methods are used, different conclusions/recommendations based on the expert judgment have been reported due to the lack of consensus in the contextual information retrieved and/or data interpretation. Future research on the field targeting sampling methods and in the laboratory regarding the assays to employ should be developed bearing in mind the different goals of the assessment.
Collapse
Affiliation(s)
- Marta Dias
- H&TRC - Health & Technology Research Center, ESTeSL - Escola Superior de Tecnologia e Saúde, Instituto Politécnico de Lisboa, Portugal; NOVA National School of Public Health, Public Health Research Centre, Comprehensive Health Research Center, CHRC, REAL, CCAL, NOVA University Lisbon, Lisbon, Portugal
| | - Bianca Gomes
- H&TRC - Health & Technology Research Center, ESTeSL - Escola Superior de Tecnologia e Saúde, Instituto Politécnico de Lisboa, Portugal; CE3C-Center for Ecology, Evolution and Environmental Change, Faculdade de Ciências, Universidade de Lisboa, 1749-016 Lisbon, Portugal
| | - Pedro Pena
- H&TRC - Health & Technology Research Center, ESTeSL - Escola Superior de Tecnologia e Saúde, Instituto Politécnico de Lisboa, Portugal; NOVA National School of Public Health, Public Health Research Centre, Comprehensive Health Research Center, CHRC, REAL, CCAL, NOVA University Lisbon, Lisbon, Portugal
| | - Renata Cervantes
- H&TRC - Health & Technology Research Center, ESTeSL - Escola Superior de Tecnologia e Saúde, Instituto Politécnico de Lisboa, Portugal; NOVA National School of Public Health, Public Health Research Centre, Comprehensive Health Research Center, CHRC, REAL, CCAL, NOVA University Lisbon, Lisbon, Portugal
| | - Alan Beswick
- Health and Safety Executive Science and Research Centre, Buxton SK17 9JN, UK
| | - Caroline Duchaine
- Département de biochimie, microbiologie et bio-informatique, Université Laval, Québec, Canada
| | - Annette Kolk
- Institute for Occupational Safety and Health of the German Social Accident Insurance, Alte Heerstraße 111, 53757 Sankt Augustin, Germany
| | - Anne Mette Madsen
- National Research Centre for the Working Environment, Lersø Parkallé 105, 2100 Copenhagen Ø, Denmark
| | | | | | | | - Inge M Wouters
- Institute for Risk Assessment Sciences (IRAS), Utrecht University, Utrecht, the Netherlands
| | - Brian Crook
- Health and Safety Executive Science and Research Centre, Buxton SK17 9JN, UK
| | - Carla Viegas
- H&TRC - Health & Technology Research Center, ESTeSL - Escola Superior de Tecnologia e Saúde, Instituto Politécnico de Lisboa, Portugal; NOVA National School of Public Health, Public Health Research Centre, Comprehensive Health Research Center, CHRC, REAL, CCAL, NOVA University Lisbon, Lisbon, Portugal.
| |
Collapse
|
2
|
Eren ZB, Vatansever C, Kabadayı B, Haykar B, Kuloğlu ZE, Ay S, Nurlybayeva K, Eyikudamacı G, Barlas T, Palaoğlu E, Beşli Y, Kuşkucu MA, Ergönül Ö, Can F. Surveillance of respiratory viruses by aerosol screening in indoor air as an early warning system for epidemics. ENVIRONMENTAL MICROBIOLOGY REPORTS 2024; 16:e13303. [PMID: 38982659 PMCID: PMC11233404 DOI: 10.1111/1758-2229.13303] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/23/2023] [Accepted: 05/15/2024] [Indexed: 07/11/2024]
Abstract
The development of effective methods for the surveillance of seasonal respiratory viruses is required for the timely management of outbreaks. We aimed to survey Influenza-A, Influenza-B, RSV-A, Rhinovirus and SARS-CoV-2 surveillance in a tertiary hospital and a campus over 5 months. The effectiveness of air screening as an early warning system for respiratory viruses was evaluated in correlation with respiratory tract panel test results. The overall viral positivity was higher on the campus than in the hospital (55.0% vs. 38.0%). Influenza A was the most prevalent pathogen in both locations. There were two influenza peaks (42nd and 49th weeks) in the hospital air, and a delayed peak was detected on campus in the 1st-week of January. Panel tests indicated a high rate of Influenza A in late December. RSV-A-positivity was higher on the campus than the hospital (21.6% vs. 7.4%). Moreover, we detected two RSV-A peaks in the campus air (48th and 51st weeks) but only one peak in the hospital and panel tests (week 49). Although rhinovirus was the most common pathogen in panel tests, rhinovirus positivity was low in air samples. The air screening for Influenza-B and SARS-Cov-2 revealed comparable positivity rates with panel tests. Air screening can be integrated into surveillance programs to support infection control programs for potential epidemics of respiratory virus infections except for rhinoviruses.
Collapse
Affiliation(s)
| | - Cansel Vatansever
- Koç University İşBank Center for Infectious Diseases (KUISCID)IstanbulTurkey
| | | | | | - Zeynep Ece Kuloğlu
- Koç University İşBank Center for Infectious Diseases (KUISCID)IstanbulTurkey
- Koç UniversityGraduate School of Health SciencesIstanbulTurkey
| | - Sedat Ay
- Koç University School of MedicineIstanbulTurkey
| | | | - Gül Eyikudamacı
- Koç University İşBank Center for Infectious Diseases (KUISCID)IstanbulTurkey
- Koç UniversityGraduate School of Health SciencesIstanbulTurkey
| | - Tayfun Barlas
- Koç University İşBank Center for Infectious Diseases (KUISCID)IstanbulTurkey
| | - Erhan Palaoğlu
- Department of Clinical LaboratoryAmerican HospitalIstanbulTurkey
| | - Yeşim Beşli
- Department of Clinical LaboratoryAmerican HospitalIstanbulTurkey
| | - Mert Ahmet Kuşkucu
- Koç University İşBank Center for Infectious Diseases (KUISCID)IstanbulTurkey
- Department of Medical MicrobiologyKoç University School of MedicineIstanbulTurkey
| | - Önder Ergönül
- Koç University İşBank Center for Infectious Diseases (KUISCID)IstanbulTurkey
- Department of Infectious Disease and Clinical MicrobiologyKoç University School of MedicineIstanbulTurkey
| | - Fusun Can
- Koç University İşBank Center for Infectious Diseases (KUISCID)IstanbulTurkey
- Department of Medical MicrobiologyKoç University School of MedicineIstanbulTurkey
| |
Collapse
|
3
|
Li X, Liu C, Wang D, Deng J, Guo Y, Shen Y, Yang S, Ji JS, Luo H, Bai J, Jiang J. Persistent pollution of genetic materials in a typical laboratory environment. JOURNAL OF HAZARDOUS MATERIALS 2024; 470:134201. [PMID: 38579585 DOI: 10.1016/j.jhazmat.2024.134201] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/26/2023] [Revised: 03/20/2024] [Accepted: 04/01/2024] [Indexed: 04/07/2024]
Abstract
From the onset of coronavirus disease (COVID-19) pandemic, there are concerns regarding the disease spread and environmental pollution of biohazard since studies on genetic engineering flourish and numerous genetic materials were used such as the nucleic acid test of the severe acute respiratory syndrome coronavirus (SARS-CoV-2). In this work, we studied genetic material pollution in an institute during a development cycle of plasmid, one of typical genetic materials, with typical laboratory settings. The pollution source, transmission routes, and pollution levels in laboratory environment were examined. The Real-Time quantitative- Polymerase Chain Reaction results of all environmental mediums (surface, aerosol, and liquid) showed that a targeted DNA segment occurred along with routine experimental operations. Among the 79 surface and air samples collected in the genetic material operation, half of the environment samples (38 of 79) are positive for nucleic acid pollution. Persistent nucleic acid contaminations were observed in all tested laboratories and spread in the public area (hallway). The highest concentration for liquid and surface samples were 1.92 × 108 copies/uL and 5.22 × 107 copies/cm2, respectively. Significant amounts of the targeted gene (with a mean value of 74 copies/L) were detected in the indoor air of laboratories utilizing centrifuge devices, shaking tables, and cell homogenizers. Spills and improper disposal of plasmid products were primary sources of pollution. The importance of establishing designated experimental zones, employing advanced biosafety cabinets, and implementing highly efficient cleaning systems in laboratories with lower biosafety levels is underscored. SYNOPSIS: STATEMENT. Persistent environmental pollutions of genetic materials are introduced by typical experiments in laboratories with low biosafety level.
Collapse
Affiliation(s)
- Xue Li
- School of Environment, Tsinghua University, Beijing, China
| | - Ce Liu
- School of Pharmaceutical Sciences, Tsinghua University, Beijing, China
| | - Dongbin Wang
- School of Environment, Tsinghua University, Beijing, China
| | - Jianguo Deng
- School of Environment, Tsinghua University, Beijing, China
| | - Yuntao Guo
- Department of Electrical Engineering, Tsinghua University, Beijing, China
| | - Yicheng Shen
- School of Environment, Tsinghua University, Beijing, China
| | - Shuwen Yang
- School of Environment, Tsinghua University, Beijing, China
| | - John S Ji
- Vanke School of Public Health, Tsinghua University, Beijing, China
| | - Haiyun Luo
- Department of Electrical Engineering, Tsinghua University, Beijing, China
| | - Jingwei Bai
- School of Pharmaceutical Sciences, Tsinghua University, Beijing, China
| | - Jingkun Jiang
- School of Environment, Tsinghua University, Beijing, China.
| |
Collapse
|
4
|
Marr LC, Samet JM. Reducing Transmission of Airborne Respiratory Pathogens: A New Beginning as the COVID-19 Emergency Ends. ENVIRONMENTAL HEALTH PERSPECTIVES 2024; 132:55001. [PMID: 38728219 PMCID: PMC11086747 DOI: 10.1289/ehp13878] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Revised: 04/10/2024] [Accepted: 04/17/2024] [Indexed: 05/12/2024]
Abstract
BACKGROUND In response to the COVID-19 pandemic, new evidence-based strategies have emerged for reducing transmission of respiratory infections through management of indoor air. OBJECTIVES This paper reviews critical advances that could reduce the burden of disease from inhaled pathogens and describes challenges in their implementation. DISCUSSION Proven strategies include assuring sufficient ventilation, air cleaning by filtration, and air disinfection by germicidal ultraviolet (UV) light. Layered intervention strategies are needed to maximize risk reduction. Case studies demonstrate how to implement these tools while also revealing barriers to implementation. Future needs include standards designed with infection resilience and equity in mind, buildings optimized for infection resilience among other drivers, new approaches and technologies to improve ventilation, scientific consensus on the amount of ventilation needed to achieve a desired level of risk, methods for evaluating new air-cleaning technologies, studies of their long-term health effects, workforce training on ventilation systems, easier access to federal funds, demonstration projects in schools, and communication with the public about the importance of indoor air quality and actions people can take to improve it. https://doi.org/10.1289/EHP13878.
Collapse
Affiliation(s)
- Linsey C. Marr
- The Charles E. Via, Jr. Department of Civil & Environmental Engineering, Virginia Polytechnic Institute and State University, Blacksburg, Virginia, USA
| | - Jonathan M. Samet
- Departments of Epidemiology and Environmental and Occupational Health, Colorado School of Public Health, Aurora, Colorado, USA
| |
Collapse
|
5
|
Anupong S, Chadsuthi S, Hongsing P, Hurst C, Phattharapornjaroen P, Rad S.M. AH, Fernandez S, Huang AT, Vatanaprasan P, Saethang T, Luk-in S, Storer RJ, Ounjai P, Devanga Ragupathi NK, Kanthawee P, Ngamwongsatit N, Badavath VN, Thuptimdang W, Leelahavanichkul A, Kanjanabuch T, Miyanaga K, Cui L, Nanbo A, Shibuya K, Kupwiwat R, Sano D, Furukawa T, Sei K, Higgins PG, Kicic A, Singer AC, Chatsuwan T, Trowsdale S, Abe S, Ishikawa H, Amarasiri M, Modchang C, Wannigama DL. Exploring indoor and outdoor dust as a potential tool for detection and monitoring of COVID-19 transmission. iScience 2024; 27:109043. [PMID: 38375225 PMCID: PMC10875567 DOI: 10.1016/j.isci.2024.109043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Revised: 11/09/2023] [Accepted: 01/23/2024] [Indexed: 02/21/2024] Open
Abstract
This study investigated the potential of using SARS-CoV-2 viral concentrations in dust as an additional surveillance tool for early detection and monitoring of COVID-19 transmission. Dust samples were collected from 8 public locations in 16 districts of Bangkok, Thailand, from June to August 2021. SARS-CoV-2 RNA concentrations in dust were quantified, and their correlation with community case incidence was assessed. Our findings revealed a positive correlation between viral concentrations detected in dust and the relative risk of COVID-19. The highest risk was observed with no delay (0-day lag), and this risk gradually decreased as the lag time increased. We observed an overall decline in viral concentrations in public places during lockdown, closely associated with reduced human mobility. The effective reproduction number for COVID-19 transmission remained above one throughout the study period, suggesting that transmission may persist in locations beyond public areas even after the lockdown measures were in place.
Collapse
Affiliation(s)
- Suparinthon Anupong
- Biophysics Group, Department of Physics, Faculty of Science, Mahidol University, Bangkok 10400, Thailand
| | - Sudarat Chadsuthi
- Department of Physics, Faculty of Science, Naresuan University, Phitsanulok 65000, Thailand
| | - Parichart Hongsing
- Mae Fah Luang University Hospital, Chiang Rai, Thailand
- School of Integrative Medicine, Mae Fah Luang University, Chiang Rai, Thailand
| | - Cameron Hurst
- Molly Wardaguga Research Centre, Charles Darwin University, Brisbane, QLD, Australia
- Statistics, QIMR Berghofer Medical Research Institute, Brisbane, QLD, Australia
| | - Phatthranit Phattharapornjaroen
- Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand
- Institute of Clinical Sciences, Department of Surgery, Sahlgrenska Academy, Gothenburg University, 40530 Gothenburg, Sweden
| | - Ali Hosseini Rad S.M.
- Department of Microbiology and Immunology, University of Otago, Dunedin, Otago 9010, New Zealand
- Center of Excellence in Immunology and Immune-Mediated Diseases, Chulalongkorn University, Bangkok 10330, Thailand
| | - Stefan Fernandez
- Department of Virology, U.S. Army Medical Directorate, Armed Forces Research Institute of Medical Sciences, Bangkok, Thailand
| | - Angkana T. Huang
- Department of Virology, U.S. Army Medical Directorate, Armed Forces Research Institute of Medical Sciences, Bangkok, Thailand
- Department of Genetics, University of Cambridge, Cambridge, UK
| | | | - Thammakorn Saethang
- Department of Computer Science, Faculty of Science, Kasetsart University, Bangkok, Thailand
| | - Sirirat Luk-in
- Department of Clinical Microbiology and Applied Technology, Faculty of Medical Technology, Mahidol University, Bangkok, Thailand
| | - Robin James Storer
- Office of Research Affairs, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
| | - Puey Ounjai
- Department of Biology, Faculty of Science, Mahidol University, Bangkok, Thailand
| | - Naveen Kumar Devanga Ragupathi
- Department of Chemical and Biological Engineering, The University of Sheffield, Sheffield, UK
- Biofilms and Antimicrobial Resistance Consortium of ODA Receiving Countries, The University of Sheffield, Sheffield, UK
- Division of Microbial Interactions, Department of Research and Development, Bioberrys Healthcare and Research Centre, Vellore 632009, India
| | - Phitsanuruk Kanthawee
- Public Health Major, School of Health Science, Mae Fah Luang University, Chiang Rai 57100, Thailand
| | - Natharin Ngamwongsatit
- Department of Clinical Sciences and Public Health, Faculty of Veterinary Science, Mahidol University, Nakhon Pathom, Thailand
| | - Vishnu Nayak Badavath
- School of Pharmacy & Technology Management, SVKM’s Narsee Monjee Institute of Management Studies (NMIMS), Hyderabad 509301, India
| | - Wanwara Thuptimdang
- Institute of Biomedical Engineering, Department of Biomedical Sciences and Biomedical Engineering, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla, Thailand
| | - Asada Leelahavanichkul
- Department of Microbiology, Faculty of Medicine, Chulalongkorn University, King Chulalongkorn Memorial Hospital, Thai Red Cross Society, Bangkok, Thailand
- Translational Research in Inflammation and Immunology Research Unit (TRIRU), Department of Microbiology, Chulalongkorn University, Bangkok, Thailand
| | - Talerngsak Kanjanabuch
- Division of Nephrology, Department of Medicine, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
- Center of Excellence in Kidney Metabolic Disorders, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
- Dialysis Policy and Practice Program (DiP3), School of Global Health, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
- Peritoneal Dialysis Excellence Center, King Chulalongkorn Memorial Hospital, Bangkok, Thailand
| | - Kazuhiko Miyanaga
- Division of Bacteriology, School of Medicine, Jichi Medical University, Tochigi, Japan
| | - Longzhu Cui
- Division of Bacteriology, School of Medicine, Jichi Medical University, Tochigi, Japan
| | - Asuka Nanbo
- The National Research Center for the Control and Prevention of Infectious Diseases, Nagasaki University, Nagasaki, Japan
| | - Kenji Shibuya
- Tokyo Foundation for Policy Research, Minato-ku, Tokyo, Japan
| | - Rosalyn Kupwiwat
- Department of Dermatology. Faculty of Medicine Siriraj Hospital. Mahidol University, Bangkok, Thailand
| | - Daisuke Sano
- Department of Frontier Sciences for Advanced Environment, Graduate School of Environmental Studies, Tohoku University, Sendai, Miyagi, Japan
- Department of Civil and Environmental Engineering, Graduate School of Engineering, Tohoku University, Sendai, Miyagi, Japan
| | - Takashi Furukawa
- Laboratory of Environmental Hygiene, Department of Health Science, School of Allied Health Sciences, Graduate School of Medical Sciences, Kitasato University, Minato City, Tokyo 108-8641, Japan
| | - Kazunari Sei
- Laboratory of Environmental Hygiene, Department of Health Science, School of Allied Health Sciences, Graduate School of Medical Sciences, Kitasato University, Minato City, Tokyo 108-8641, Japan
| | - Paul G. Higgins
- Institute for Medical Microbiology, Immunology and Hygiene, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
- German Centre for Infection Research, Partner Site Bonn-Cologne, Cologne, Germany
| | - Anthony Kicic
- Wal-Yan Respiratory Research Centre, Telethon Kids Institute, University of Western Australia, Nedlands WA 6009, Australia
- Centre for Cell Therapy and Regenerative Medicine, Medical School, The University of Western Australia, Nedlands, WA 6009, Australia
- Department of Respiratory and Sleep Medicine, Perth Children’s Hospital, Nedlands WA 6009, Australia
- School of Population Health, Curtin University, Bentley WA 6102, Australia
| | | | - Tanittha Chatsuwan
- Department of Microbiology, Faculty of Medicine, Chulalongkorn University, King Chulalongkorn Memorial Hospital, Thai Red Cross Society, Bangkok, Thailand
- Center of Excellence in Antimicrobial Resistance and Stewardship, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
| | - Sam Trowsdale
- Department of Environmental Science, University of Auckland, Auckland 1010, New Zealand
| | - Shuichi Abe
- Department of Infectious Diseases and Infection Control, Yamagata Prefectural Central Hospital, Yamagata, Japan
| | - Hitoshi Ishikawa
- Yamagata Prefectural University of Health Sciences, Kamiyanagi, Yamagata 990-2212, Japan
| | - Mohan Amarasiri
- Laboratory of Environmental Hygiene, Department of Health Science, School of Allied Health Sciences, Graduate School of Medical Sciences, Kitasato University, Minato City, Tokyo 108-8641, Japan
| | - Charin Modchang
- Biophysics Group, Department of Physics, Faculty of Science, Mahidol University, Bangkok 10400, Thailand
- Centre of Excellence in Mathematics, MHESI, Bangkok 10400, Thailand
- Thailand Center of Excellence in Physics, Ministry of Higher Education, Science, Research and Innovation, 328 Si Ayutthaya Road, Bangkok 10400, Thailand
| | - Dhammika Leshan Wannigama
- Biofilms and Antimicrobial Resistance Consortium of ODA Receiving Countries, The University of Sheffield, Sheffield, UK
- Department of Microbiology, Faculty of Medicine, Chulalongkorn University, King Chulalongkorn Memorial Hospital, Thai Red Cross Society, Bangkok, Thailand
- Center of Excellence in Antimicrobial Resistance and Stewardship, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
- Department of Infectious Diseases and Infection Control, Yamagata Prefectural Central Hospital, Yamagata, Japan
- Yamagata Prefectural University of Health Sciences, Kamiyanagi, Yamagata 990-2212, Japan
- School of Medicine, Faculty of Health and Medical Sciences, The University of Western Australia, Nedlands, WA, Australia
- Pathogen Hunter’s Research Collaborative Team, Department of Infectious Diseases and Infection Control, Yamagata Prefectural Central Hospital, Yamagata, Japan
| |
Collapse
|
6
|
Raphe P, Fellouah H, Poncet S, Ameur M. "Parametric study on the age of air in a full-scale office room using perforated duct diffusers.". Heliyon 2024; 10:e26667. [PMID: 38463864 PMCID: PMC10923659 DOI: 10.1016/j.heliyon.2024.e26667] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2022] [Revised: 03/28/2023] [Accepted: 02/16/2024] [Indexed: 03/12/2024] Open
Abstract
Following the recent pandemic of COVID-19, scientists have made many efforts to devise a workable solution for it, worldwide. However, it was shown that the protective effect of a well-conditioning system is as high as five times in comparison to the face-covering and other proposed procedures. In this context, the age of air and the type of filtration systems in closed spaces became the critical criteria for comparing the capability of ventilation systems. In this paper, a validated numerical model for the perforated duct diffusers is used to study the behaviour of the local age of air at the full-scale office with 8 feet (2.44 [m]) height, under various initial conditions like initial velocity and air change per hour. Also, different geometries for the ducts have been investigated under the same initial condition, as well as the effect of direction, ventilation effectiveness, and flow pattern. Finally, the volume average of the age of air at different zones has been nominated to perform the sensitivity analysis of each variable based on the variation of the airflow. The results show that diffusers with vertical perforations would be more effective during the pandemic than the other types in airborne mitigation. Moreover, the highest available airflow shall be set until such time there is no windy area in the breathing zone. Within these modifications, the residence time of the infectious nuclei in the breathing zone may decrease by up to 30%.
Collapse
Affiliation(s)
- Peyman Raphe
- Department of Mechanical Engineering, Université de Sherbrooke, Sherbrooke, QC, Canada
| | - Hachimi Fellouah
- Department of Mechanical Engineering, Université de Sherbrooke, Sherbrooke, QC, Canada
| | - Sébastien Poncet
- Department of Mechanical Engineering, Université de Sherbrooke, Sherbrooke, QC, Canada
| | | |
Collapse
|
7
|
Srikrishna D. Pentagon Found Daily, Metagenomic Detection of Novel Bioaerosol Threats to Be Cost-Prohibitive: Can Virtualization and AI Make It Cost-Effective? Health Secur 2024; 22:108-129. [PMID: 38625036 DOI: 10.1089/hs.2023.0048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/17/2024] Open
Abstract
In 2022, the Pentagon Force Protection Agency found threat agnostic detection of novel bioaerosol threats to be "not feasible for daily operations" due to the cost of reagents used for metagenomics, cost of sequencing instruments, and cost of labor for subject matter experts to analyze bioinformatics. Similar operational difficulties might extend to many of the 280,000 buildings (totaling 2.3 billion square feet) at 5,000 secure US Department of Defense military sites, 250 Navy ships, as well as many civilian buildings. These economic barriers can still be addressed in a threat agnostic manner by dynamically pooling samples from dry filter units, called spike-triggered virtualization, whereby pooling and sequencing depth are automatically modulated based on novel biothreats in the sequencing output. By running at a high average pooling factor, the daily and annual cost per dry filter unit can be reduced by 10 to 100 times depending on the chosen trigger thresholds. Artificial intelligence can further enhance the sensitivity of spike-triggered virtualization. The risk of infection during the 12- to 24-hour window between a bioaerosol incident and its detection remains, but in some cases it can be reduced by 80% or more with high-speed indoor air cleaning exceeding 12 air changes per hour, which is similar to the rate of air cleaning in passenger airplanes in flight. That level of air changes per hour or higher is likely to be cost-prohibitive using central heating ventilation and air conditioning systems, but it can be achieved economically by using portable air filtration in rooms with typical ceiling heights (less than 10 feet) for a cost of approximately $0.50 to $1 per square foot for do-it-yourself units and $2 to $5 per square foot for high-efficiency particulate air filters.
Collapse
|
8
|
Haowei Y, Mahyuddin N, Bin Nik Ghazali NN, Wang Z, Liu Y, Pan S, Badruddin IA. A critical review of research methodologies for COVID-19 transmission in indoor built environment. INTERNATIONAL JOURNAL OF ENVIRONMENTAL HEALTH RESEARCH 2024:1-65. [PMID: 38385569 DOI: 10.1080/09603123.2024.2308731] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2023] [Accepted: 01/17/2024] [Indexed: 02/23/2024]
Abstract
The Coronavirus Disease 2019 (COVID-19) has caused massive losses for the global economy. Scholars have used different methods to study the transmission mode and influencing factors of the virus to find effective methods to provide people with a healthy built environment. However, these studies arrived at different or even contradictory conclusions. This review presents the main research methodologies utilized in this field, summarizes the main investigation methods, and critically discusses their related conclusions. Data statistical analysis, sample collection, simulation models, and replication transmission scenarios are the main research methods. The summarized conclusion for prevention from all reviewed papers are: adequate ventilation and proper location of return air vents, proper use of personal protective equipment, as well as the reasonable and strict enforcement of policies are the main methods for reducing the transmission. Recommendations including standardized databases, causation clarification, rigorous experiment design, improved simulation accuracy and verification are provided.
Collapse
Affiliation(s)
- Yu Haowei
- Centre for Building, Construction & Tropical Architecture (BuCTA), Faculty of Built Environment, University of Malaya, Kuala Lumpur, Malaysia
| | - Norhayati Mahyuddin
- Centre for Building, Construction & Tropical Architecture (BuCTA), Faculty of Built Environment, University of Malaya, Kuala Lumpur, Malaysia
| | - Nik Nazri Bin Nik Ghazali
- Department of Mechanical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
| | - Zeyu Wang
- China Nuclear Power Engineering Co. Ltd, Beijing Institute of Nuclear Engineering, Beijing, China
| | - Yiqiao Liu
- Department of Mechanical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
| | - Song Pan
- Beijing Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing, China
- Key Laboratory for Comprehensive Energy Saving of Cold Regions Architecture of Ministry of Education, Jilin Jianzhu University, Changchun, PR China
| | - Irfan Anjum Badruddin
- Mechanical Engineering Department, College of Engineering, King Khalid University, Abha, Saudi Arabia
| |
Collapse
|
9
|
Zhang Y, Shankar SN, Vass WB, Lednicky JA, Fan ZH, Agdas D, Makuch R, Wu CY. Air Change Rate and SARS-CoV-2 Exposure in Hospitals and Residences: A Meta-Analysis. AEROSOL SCIENCE AND TECHNOLOGY : THE JOURNAL OF THE AMERICAN ASSOCIATION FOR AEROSOL RESEARCH 2024; 58:217-243. [PMID: 38764553 PMCID: PMC11101186 DOI: 10.1080/02786826.2024.2312178] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/23/2023] [Accepted: 01/16/2024] [Indexed: 05/21/2024]
Abstract
As SARS-CoV-2 swept across the globe, increased ventilation and implementation of air cleaning were emphasized by the US CDC and WHO as important strategies to reduce the risk of inhalation exposure to the virus. To assess whether higher ventilation and air cleaning rates lead to lower exposure risk to SARS-CoV-2, 1274 manuscripts published between April 2020 and September 2022 were screened using key words "airborne SARS-CoV-2 or "SARS-CoV-2 aerosol". Ninety-three studies involved air sampling at locations with known sources (hospitals and residences) were selected and associated data were compiled. Two metrics were used to assess exposure risk: SARS-CoV-2 concentration and SARS-CoV-2 detection rate in air samples. Locations were categorized by type (hospital or residence) and proximity to the sampling location housing the isolated/quarantined patient (primary or secondary). The results showed that hospital wards had lower airborne virus concentrations than residential isolation rooms. A negative correlation was found between airborne virus concentrations in primary-occupancy areas and air changes per hour (ACH). In hospital settings, sample positivity rates were significantly reduced in secondary-occupancy areas compared to primary-occupancy areas, but they were similar across sampling locations in residential settings. ACH and sample positivity rates were negatively correlated, though the effect was diminished when ACH values exceeded 8. While limitations associated with diverse sampling protocols exist, data considered by this meta-analysis support the notion that higher ACH may reduce exposure risks to the virus in ambient air.
Collapse
Affiliation(s)
- Yuetong Zhang
- Department of Environmental Engineering Sciences, University of Florida, Gainesville, Florida, USA
- Department of Mechanical Engineering, University of British Columbia, Vancouver, British Columnia, Canada
| | - Sripriya Nannu Shankar
- Department of Environmental Engineering Sciences, University of Florida, Gainesville, Florida, USA
- Department of Environmental & Public Health Sciences, University of Cincinnati, Cincinnati, Ohio, USA
| | - William B. Vass
- Department of Environmental Engineering Sciences, University of Florida, Gainesville, Florida, USA
| | - John A. Lednicky
- Department of Environmental and Global Health, University of Florida, Gainesville, Florida, USA
- Emerging Pathogens Institute, University of Florida, Gainesville, Florida, USA
| | - Z. Hugh Fan
- Mechanical and Aerospace Engineering, University of Florida, Gainesville, Florida, USA
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, Florida, USA
| | - Duzgun Agdas
- Engineering School of Sustainable Infrastructure & Environment, University of Florida, Gainesville, Florida, USA
| | - Robert Makuch
- Department of Biostatistics, Yale University School of Public Health, New Haven, Connecticut, USA
| | - Chang-Yu Wu
- Department of Environmental Engineering Sciences, University of Florida, Gainesville, Florida, USA
- Department of Chemical, Environmental, and Materials Engineering, University of Miami, Coral Gables, Florida, USA
| |
Collapse
|
10
|
Ijaz MK, Sattar SA, Nims RW, Boone SA, McKinney J, Gerba CP. Environmental dissemination of respiratory viruses: dynamic interdependencies of respiratory droplets, aerosols, aerial particulates, environmental surfaces, and contribution of viral re-aerosolization. PeerJ 2023; 11:e16420. [PMID: 38025703 PMCID: PMC10680453 DOI: 10.7717/peerj.16420] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2023] [Accepted: 10/17/2023] [Indexed: 12/01/2023] Open
Abstract
During the recent pandemic of COVID-19 (SARS-CoV-2), influential public health agencies such as the World Health Organization (WHO) and the U.S. Centers for Disease Control and Prevention (CDC) have favored the view that SARS CoV-2 spreads predominantly via droplets. Many experts in aerobiology have openly opposed that stance, forcing a vigorous debate on the topic. In this review, we discuss the various proposed modes of viral transmission, stressing the interdependencies between droplet, aerosol, and fomite spread. Relative humidity and temperature prevailing determine the rates at which respiratory aerosols and droplets emitted from an expiratory event (sneezing, coughing, etc.) evaporate to form smaller droplets or aerosols, or experience hygroscopic growth. Gravitational settling of droplets may result in contamination of environmental surfaces (fomites). Depending upon human, animal and mechanical activities in the occupied space indoors, viruses deposited on environmental surfaces may be re-aerosolized (re-suspended) to contribute to aerosols, and can be conveyed on aerial particulate matter such as dust and allergens. The transmission of respiratory viruses may then best be viewed as resulting from dynamic virus spread from infected individuals to susceptible individuals by various physical states of active respiratory emissions, instead of the current paradigm that emphasizes separate dissemination by respiratory droplets, aerosols or by contaminated fomites. To achieve the optimum outcome in terms of risk mitigation and infection prevention and control (IPAC) during seasonal infection peaks, outbreaks, and pandemics, this holistic view emphasizes the importance of dealing with all interdependent transmission modalities, rather than focusing on one modality.
Collapse
Affiliation(s)
- M. Khalid Ijaz
- Global Research & Development for Lysol and Dettol, Reckitt Benckiser LLC, Montvale, NJ, United States of America
| | - Syed A. Sattar
- Department of Biochemistry, Microbiology & Immunology, Faculty of Medicine, University of Ottawa, Ottawa, Ontario, Canada
| | | | - Stephanie A. Boone
- Water & Energy Sustainable Technology Center, University of Arizona, Tucson, AZ, United States of America
| | - Julie McKinney
- Global Research & Development for Lysol and Dettol, Reckitt Benckiser LLC, Montvale, NJ, United States of America
| | - Charles P. Gerba
- Water & Energy Sustainable Technology Center, University of Arizona, Tucson, AZ, United States of America
| |
Collapse
|
11
|
Acharya A, Surbaugh K, Thurman M, Wickramaratne C, Myers P, Mittal R, Pandey K, Klug E, Stein SJ, Ravnholdt AR, Herrera VL, Rivera DN, Williams P, Santarpia JL, Kaushik A, Dhau JS, Byrareddy SN. Efficient trapping and destruction of SARS-CoV-2 using PECO-assisted Molekule air purifiers in the laboratory and real-world settings. ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY 2023; 264:115487. [PMID: 37729804 DOI: 10.1016/j.ecoenv.2023.115487] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/28/2023] [Revised: 09/04/2023] [Accepted: 09/13/2023] [Indexed: 09/22/2023]
Abstract
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is transmitted human-to-human via aerosols and air-borne droplets. Therefore, capturing and destroying viruses from indoor premises are essential to reduce the probability of human exposure and virus transmission. While the heating, ventilation, and air conditioning (HVAC) systems help in reducing the indoor viral load, a targeted approach is required to effectively remove SARS-CoV-2 from indoor air to address human exposure concerns. The present study demonstrates efficient trapping and destruction of SARS-CoV-2 via nano-enabled filter technology using the UV-A-stimulated photoelectrochemical oxidation (PECO) process. Aerosols containing SARS-CoV-2 were generated by nebulization inside an air-controlled test chamber where an air purifier (Air Mini+) was placed. The study demonstrated the efficient removal of SARS-CoV-2 (99.98 %) from the test chamber in less than two minutes and PECO-assisted destruction (over 99%) on the filtration media in 1 h. Furthermore, in a real-world scenario, the Molekule Air-Pro air purifier removed SARS-CoV-2 (a negative RT-qPCR result post-running the filter device) from the circulating air in a COVID-19 testing facility. Overall, the ability of two FDA-approved class II medical devices, Molekule Air-Mini+ and Air-Pro air purifiers, to remove and destroy SARS-CoV-2 in indoor settings was successfully demonstrated. The study indicates that as the "tripledemic" of COVID-19, influenza, and respiratory syncytial virus (RSV) overwhelm the healthcare facilities in the USA, the use of a portable air filtration device will help contain the spread of the viruses in close door facilities, such as in schools and daycare facilities.
Collapse
Affiliation(s)
- Arpan Acharya
- Department of Pharmacology and Experimental Neuroscience, University of Nebraska Medical Center, Omaha, NE 68131, USA
| | - Kerri Surbaugh
- Research and Development, Molekule, Inc., 3802 Spectrum Blvd, Tampa, FL 33612, USA
| | - Michellie Thurman
- Department of Pharmacology and Experimental Neuroscience, University of Nebraska Medical Center, Omaha, NE 68131, USA
| | | | - Philip Myers
- Research and Development, Molekule, Inc., 3802 Spectrum Blvd, Tampa, FL 33612, USA
| | - Rajat Mittal
- Clean Energy Research Center, University of South Florida, Tampa, FL 33612, USA
| | - Kabita Pandey
- Department of Pharmacology and Experimental Neuroscience, University of Nebraska Medical Center, Omaha, NE 68131, USA
| | - Elizabeth Klug
- Department of Pharmacology and Experimental Neuroscience, University of Nebraska Medical Center, Omaha, NE 68131, USA
| | - Sarah J Stein
- Department of Pathology and Microbiology, University of Nebraska Medical Center, Omaha, NE, USA
| | - Ashley R Ravnholdt
- Department of Pathology and Microbiology, University of Nebraska Medical Center, Omaha, NE, USA
| | - Vicki L Herrera
- Department of Pathology and Microbiology, University of Nebraska Medical Center, Omaha, NE, USA
| | - Danielle N Rivera
- Department of Pathology and Microbiology, University of Nebraska Medical Center, Omaha, NE, USA
| | - Paul Williams
- Department of Pathology and Microbiology, University of Nebraska Medical Center, Omaha, NE, USA
| | - Joshua L Santarpia
- Department of Pathology and Microbiology, University of Nebraska Medical Center, Omaha, NE, USA
| | - Ajeet Kaushik
- Department of Environmental Engineering, Florida Polytechnic University, 4700 Research Way, Lakeland, FL 33805, USA; Department of Genetics, Cell Biology, and Anatomy, University of Nebraska Medical Center, Omaha, NE 68131, USA
| | - Jaspreet S Dhau
- Research and Development, Molekule, Inc., 3802 Spectrum Blvd, Tampa, FL 33612, USA.
| | - Siddappa N Byrareddy
- Department of Pharmacology and Experimental Neuroscience, University of Nebraska Medical Center, Omaha, NE 68131, USA; Department of Environmental Engineering, Florida Polytechnic University, 4700 Research Way, Lakeland, FL 33805, USA; Department of Genetics, Cell Biology, and Anatomy, University of Nebraska Medical Center, Omaha, NE 68131, USA; Department of Biochemistry and Molecular Biology, University of Nebraska Medical Center, Omaha, NE 68131, USA.
| |
Collapse
|
12
|
Chen R, Bao J, Huang X, Chen Q, Huang M, Gao M, Yu F, Chen J, Zou W, Shi L, Chen X, Feng B, Wang R, Feng B, Zheng S, Yu F. Comparison of "hock-a-loogie" saliva versus nasopharyngeal and oropharyngeal swabs for detecting common respiratory pathogens. Heliyon 2023; 9:e20965. [PMID: 37867842 PMCID: PMC10587520 DOI: 10.1016/j.heliyon.2023.e20965] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2023] [Revised: 10/10/2023] [Accepted: 10/12/2023] [Indexed: 10/24/2023] Open
Abstract
Self-collection of saliva samples has attracted considerable attention in recent years, particularly during the coronavirus disease 2019 pandemic. However, studies investigating the detection of other common respiratory pathogens in saliva samples are limited. In this study, nasopharyngeal swabs (NPS), oropharyngeal swabs (OPS), and "hock-a-loogie" saliva (HLS) were collected from 469 patients to detect 13 common respiratory pathogens. Overall positivity rates for NPS (66.1 %), HLS (63.5 %), and OPS (57.8 %) were statistically different (P = 0.028), with an overall concordance of 72.7 %. Additionally, detection rates for NPS (85.9 %) and HLS (83.2 %) for all pathogens were much higher than for OPS (73.3 %). Coronavirus and human rhinovirus were most frequently detected pathogens in NPS (P < 0.001). Mycoplasma pneumoniae was significantly more prevalent in the HLS group (P = 0.008). In conclusion, NPS was a reliable sample type for detecting common respiratory pathogens. HLS was more easily collected and can be used in emergencies or specific conditions. Mixed NPS/OPS and NPS/HLS specimens have the potential to improve detection rates, although OPS testing alone has a relatively high risk for missed detection.
Collapse
Affiliation(s)
- Renke Chen
- The First Clinical Medical College, Zhejiang Chinese Medical University, Hangzhou, China
| | - Jiaqi Bao
- Department of Laboratory Medicine, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
- Key Laboratory of Clinical In Vitro Diagnostic Techniques of Zhejiang Province, Hangzhou, China
- Institute of Laboratory Medicine, Zhejiang University, Hangzhou, China
| | - Xiaojuan Huang
- Department of Laboratory Medicine, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Qianna Chen
- Department of Laboratory Medicine, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Maowen Huang
- Center of Clinical Laboratory, Ningbo Beilun People's Hospital, Ningbo, China
| | - Min Gao
- Department of Clinical Laboratory, Huzhou Central Hospital, Affiliated Central Hospital Huzhou University, Huzhou, China
| | - Fanghao Yu
- Department of Clinical Laboratory, Yiwu Central Hospital, Yiwu, China
| | - Jiayao Chen
- Department of Clinical Laboratory, Zhoushan Hospital of Zhejiang Province, Zhoushan, China
| | - Weihua Zou
- Department of Clinical Laboratory, Huzhou Central Hospital, Affiliated Central Hospital Huzhou University, Huzhou, China
| | - Lumei Shi
- Center of Clinical Laboratory, Ningbo Beilun People's Hospital, Ningbo, China
| | - Xiao Chen
- Department of Laboratory Medicine, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
- Key Laboratory of Clinical In Vitro Diagnostic Techniques of Zhejiang Province, Hangzhou, China
- Institute of Laboratory Medicine, Zhejiang University, Hangzhou, China
| | - Bo Feng
- Department of Nephrology, Jiaxing Hospital of Traditional Chinese Medicine, Jiaxing, China
| | - Ruonan Wang
- Department of Laboratory Medicine, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
- Key Laboratory of Clinical In Vitro Diagnostic Techniques of Zhejiang Province, Hangzhou, China
- Institute of Laboratory Medicine, Zhejiang University, Hangzhou, China
| | - Baihuan Feng
- Department of Laboratory Medicine, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
- Key Laboratory of Clinical In Vitro Diagnostic Techniques of Zhejiang Province, Hangzhou, China
- Institute of Laboratory Medicine, Zhejiang University, Hangzhou, China
| | - Shufa Zheng
- Department of Laboratory Medicine, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
- Key Laboratory of Clinical In Vitro Diagnostic Techniques of Zhejiang Province, Hangzhou, China
- Institute of Laboratory Medicine, Zhejiang University, Hangzhou, China
| | - Fei Yu
- Department of Laboratory Medicine, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
- Key Laboratory of Clinical In Vitro Diagnostic Techniques of Zhejiang Province, Hangzhou, China
- Institute of Laboratory Medicine, Zhejiang University, Hangzhou, China
| |
Collapse
|
13
|
Martínez-Espinosa E, Carvajal-Mariscal I. Virus-laden droplet nuclei in vortical structures associated with recirculation zones in indoor environments: A possible airborne transmission of SARS-CoV-2. ENVIRONMENTAL ADVANCES 2023; 12:100376. [PMID: 37193349 PMCID: PMC10163794 DOI: 10.1016/j.envadv.2023.100376] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Accepted: 05/03/2023] [Indexed: 05/18/2023]
Abstract
Droplet nuclei dispersion patterns in indoor environments are reviewed from a physics view to explore the possibility of airborne transmission of SARS-CoV-2. This review analyzes works on particle dispersion patterns and their concentration in vortical structures in different indoor environments. Numerical simulations and experiments reveal the formation of the buildings' recirculation zones and vortex flow regions by flow separation, airflow interaction around objects, internal dispersion of airflow, or thermal plume. These vortical structures showed high particle concentration because particles are trapped for long periods. Then a hypothesis is proposed to explain why some medical studies detect the presence of SARS-CoV-2 and others do not detect the virus. The hypothesis proposes that airborne transmission is possible if virus-laden droplet nuclei are trapped in vortical structures associated with recirculation zones. This hypothesis is reinforced by a numerical study in a restaurant that presented possible evidence of airborne transmission by a large recirculating air zone. Furthermore, a medical study in a hospital is discussed from a physical view for identifying the formation of recirculation zones and their relation with positive tests for viruses. The observations show air sampling site located in this vortical structure is positive for the SARS-CoV-2 RNA. Therefore, the formation of vortical structures associated with recirculation zones should be avoided to minimize the possibility of airborne transmission. This work tries to understand the complex phenomenon of airborne transmission as a way in the prevention of transmission of infectious diseases.
Collapse
Affiliation(s)
- E Martínez-Espinosa
- Industrial and Environmental Processes Department, Instituto de Ingeniería, UNAM, Ciudad Universitaria, Mexico City 04510, México
| | | |
Collapse
|
14
|
Abubakar-Waziri H, Kalaiarasan G, Wawman R, Hobbs F, Adcock I, Dilliway C, Fang F, Pain C, Porter A, Bhavsar PK, Ransome E, Savolainen V, Kumar P, Chung KF. SARS-CoV2 in public spaces in West London, UK during COVID-19 pandemic. BMJ Open Respir Res 2023; 10:10/1/e001574. [PMID: 37202121 DOI: 10.1136/bmjresp-2022-001574] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Accepted: 04/28/2023] [Indexed: 05/20/2023] Open
Abstract
BACKGROUND Spread of SARS-CoV2 by aerosol is considered an important mode of transmission over distances >2 m, particularly indoors. OBJECTIVES We determined whether SARS-CoV2 could be detected in the air of enclosed/semi-enclosed public spaces. METHODS AND ANALYSIS Between March 2021 and December 2021 during the easing of COVID-19 pandemic restrictions after a period of lockdown, we used total suspended and size-segregated particulate matter (PM) samplers for the detection of SARS-CoV2 in hospitals wards and waiting areas, on public transport, in a university campus and in a primary school in West London. RESULTS We collected 207 samples, of which 20 (9.7%) were positive for SARS-CoV2 using quantitative PCR. Positive samples were collected from hospital patient waiting areas, from hospital wards treating patients with COVID-19 using stationary samplers and from train carriages in London underground using personal samplers. Mean virus concentrations varied between 429 500 copies/m3 in the hospital emergency waiting area and the more frequent 164 000 copies/m3 found in other areas. There were more frequent positive samples from PM samplers in the PM2.5 fractions compared with PM10 and PM1. Culture on Vero cells of all collected samples gave negative results. CONCLUSION During a period of partial opening during the COVID-19 pandemic in London, we detected SARS-CoV2 RNA in the air of hospital waiting areas and wards and of London Underground train carriage. More research is needed to determine the transmission potential of SARS-CoV2 detected in the air.
Collapse
Affiliation(s)
| | - Gopinath Kalaiarasan
- Department of Civil and Environmental Engineering, Global Centre for Clean Air Research, Surrey, UK
| | - Rebecca Wawman
- Airway Disease, National Heart & Lung Institute, Imperial College London, London, UK
| | - Faye Hobbs
- Airway Disease, National Heart & Lung Institute, Imperial College London, London, UK
| | - Ian Adcock
- Airway Disease, National Heart & Lung Institute, Imperial College London, London, UK
| | - Claire Dilliway
- Airway Disease, National Heart & Lung Institute, Imperial College London, London, UK
| | - Fangxin Fang
- Airway Disease, National Heart & Lung Institute, Imperial College London, London, UK
| | - Christopher Pain
- Airway Disease, National Heart & Lung Institute, Imperial College London, London, UK
| | - Alexandra Porter
- Airway Disease, National Heart & Lung Institute, Imperial College London, London, UK
| | - Pankaj K Bhavsar
- Airway Disease, National Heart & Lung Institute, Imperial College London, London, UK
| | - Emma Ransome
- Airway Disease, National Heart & Lung Institute, Imperial College London, London, UK
| | - Vincent Savolainen
- Airway Disease, National Heart & Lung Institute, Imperial College London, London, UK
| | - Prashant Kumar
- Department of Civil and Environmental Engineering, Global Centre for Clean Air Research, Surrey, UK
| | - Kian Fan Chung
- Airway Disease, National Heart & Lung Institute, Imperial College London, London, UK
| |
Collapse
|
15
|
Lin SC, Yeh HT, Lee YH, Hsu SM. mHealth and eHealth Applications for a Medicalized Quarantine Hotel during the COVID-19 Pandemic. Appl Clin Inform 2023; 14:575-584. [PMID: 37494971 PMCID: PMC10371401 DOI: 10.1055/s-0043-1769912] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Accepted: 05/01/2023] [Indexed: 07/28/2023] Open
Abstract
BACKGROUND In Taiwan, the number of confirmed cases of coronavirus disease 2019 (COVID-19) has risen significantly in May 2021. The second wave of the epidemic occurred in May 2022. mHealth (mobile health, social media communities) and eHealth (electronic health, Hospital Information System) can play an important role in this pandemic by minimizing the spread of the virus, leveraging health care providers' time, and alleviating the challenges of medical education. OBJECTIVES This study aimed to describe the process of using mHealth and eHealth to build a medicalized quarantine hotel (MQH) and understand the physical and mental impact of COVID-19 on patients admitted to the MQH. METHODS In this retrospective observational study, data from 357 patients who stayed at the MQH were collected and their psychological symptoms were assessed using an online Brief Symptom Rating Scale (BSRS). Descriptive statistics, independent sample t-test, univariate analysis of variance, and multiple linear regression analysis were performed. RESULTS The patients' mean age was 35.5 ± 17.6 years, and 52.1% (n = 186) of them were males. Altogether, 25.2% (n = 90) of the patients had virtual visits. The average duration of the hotel stay was 6.8 ± 1.4 days, and five patients (0.01%) were transferred to the hospital. The three most common symptoms reported were cough (39%), followed by the sore throat (22.8%), and stuffy/runny nose (18.9%). Most patients achieved a total BSRS score of 0 to 5 points (3,569/91.0%), with trouble falling asleep (0.65 ± 0.65), feeling tense or high-strung (0.31 ± 0.66), and feeling down or depressed (0.27 ± 0.62) scoring highest. The BSRS score was the highest on the first day. The sex of the patients was significantly related to the BSRS score (p < 0.001). CONCLUSION mHealth and eHealth can be used to further monitor an individual's physiological and psychological states. Early intervention measures are needed to improve health care quality.
Collapse
Affiliation(s)
- Shu-Chuan Lin
- Nursing Department, MacKay Memorial Hospital, Taipei, Taiwan
- Department of Nursing, Mackay Medical College, Taipei, Taiwan
| | - Hui-Tzu Yeh
- Nursing Department, MacKay Memorial Hospital, Taipei, Taiwan
- Department of Nursing, Mackay Medical College, Taipei, Taiwan
| | - Yu-Hsia Lee
- Nursing Department, MacKay Memorial Hospital, Taipei, Taiwan
- Nursing Department, Mackay Junior College of Medicine, Taipei, Taiwan
| | - Suh-Meei Hsu
- Nursing Department, MacKay Memorial Hospital, Taipei, Taiwan
- Nursing Department, Mackay Junior College of Medicine, Taipei, Taiwan
- Department of Nursing, College of Nursing, National Taipei University of Nursing and Health Sciences, Taipei, Taiwan
| |
Collapse
|
16
|
Zoran MA, Savastru RS, Savastru DM, Tautan MN. Peculiar weather patterns effects on air pollution and COVID-19 spread in Tokyo metropolis. ENVIRONMENTAL RESEARCH 2023; 228:115907. [PMID: 37080275 PMCID: PMC10111861 DOI: 10.1016/j.envres.2023.115907] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/08/2023] [Revised: 04/11/2023] [Accepted: 04/12/2023] [Indexed: 05/03/2023]
Abstract
As a pandemic hotspot in Japan, between March 1, 2020-October 1, 2022, Tokyo metropolis experienced seven COVID-19 waves. Motivated by the high rate of COVID-19 incidence and mortality during the seventh wave, and environmental/health challenges we conducted a time-series analysis to investigate the long-term interaction of air quality and climate variability with viral pandemic in Tokyo. Through daily time series geospatial and observational air pollution/climate data, and COVID-19 incidence and death cases, this study compared the environmental conditions during COVID-19 multiwaves. In spite of five State of Emergency (SOEs) restrictions associated with COVID-19 pandemic, during (2020-2022) period air quality recorded low improvements relative to (2015-2019) average annual values, namely: Aerosol Optical Depth increased by 9.13% in 2020 year, and declined by 6.64% in 2021, and 12.03% in 2022; particulate matter PM2.5 and PM10 decreased during 2020, 2021, and 2022 years by 10.22%, 62.26%, 0.39%, and respectively by 4.42%, 3.95%, 5.76%. For (2021-2022) period the average ratio of PM2.5/PM10 was (0.319 ± 0.1640), showing a higher contribution to aerosol loading of traffic-related coarse particles in comparison with fine particles. The highest rates of the daily recorded COVID-19 incidence and death cases in Tokyo during the seventh COVID-19 wave (1 July 2022-1 October 2022) may be attributed to accumulation near the ground of high levels of air pollutants and viral pathogens due to: 1) peculiar persistent atmospheric anticyclonic circulation with strong positive anomalies of geopotential height at 500 hPa; 2) lower levels of Planetary Boundary Layer (PBL) heights; 3) high daily maximum air temperature and land surface temperature due to the prolonged heat waves (HWs) in summer 2022; 4) no imposed restrictions. Such findings can guide public decision-makers to design proper strategies to curb pandemics under persistent stable anticyclonic weather conditions and summer HWs in large metropolitan areas.
Collapse
Affiliation(s)
- Maria A Zoran
- IT Department, National Institute of R&D for Optoelectronics, Atomistilor Street 409, MG5, Magurele-Bucharest, 077125, Romania.
| | - Roxana S Savastru
- IT Department, National Institute of R&D for Optoelectronics, Atomistilor Street 409, MG5, Magurele-Bucharest, 077125, Romania
| | - Dan M Savastru
- IT Department, National Institute of R&D for Optoelectronics, Atomistilor Street 409, MG5, Magurele-Bucharest, 077125, Romania
| | - Marina N Tautan
- IT Department, National Institute of R&D for Optoelectronics, Atomistilor Street 409, MG5, Magurele-Bucharest, 077125, Romania
| |
Collapse
|
17
|
Fukuda K, Baba H, Yoshida M, Kitabayashi K, Katsushima S, Sonehara H, Mizuno K, Kanamori H, Tokuda K, Nakagawa A, Mizuno A. Novel Virus Air Sampler Based on Electrostatic Precipitation and Air Sampling of SARS-CoV-2. Microorganisms 2023; 11:microorganisms11040944. [PMID: 37110367 PMCID: PMC10143856 DOI: 10.3390/microorganisms11040944] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Revised: 03/23/2023] [Accepted: 03/31/2023] [Indexed: 04/29/2023] Open
Abstract
The assessment of airborne viruses in air is a critical step in the design of appropriate prevention and control measures. Hence, herein, we developed a novel wet-type electrostatic air sampler using a viral dissolution buffer containing a radical scavenging agent, and verified the concentration of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) RNA in the air of hospital rooms inhabiting coronavirus disease 2019 (COVID-19) patients and public areas. RNA damage caused by corona discharge was negligible when Buffer AVL was used as the collecting electrode. The viral RNA concentration in the air of the room varied by patient: 3.9 × 103 copy/m3 on the 10th day after onset in a mild case and 1.3 × 103 copy/m3 on the 18th day in a severe case. Viral RNA levels were 7.8 × 102 and 1.9 × 102 copy/m3 in the air of the office and food court, respectively, where people removed their masks when eating and talking, but it remained undetected in the station corridor where all the people were wearing masks. The assessment of airborne SARS-CoV-2 RNA using the proposed sampler can serve as a basis for the safe discontinuation of COVID-19 isolation precautions to identify exposure hotspots and alert individuals at increased infection risks.
Collapse
Affiliation(s)
- Kyohei Fukuda
- AMANO Co., Ltd., 275 Mamedocho, Kohoku-ku, Yokohama 222-8558, Japan
| | - Hiroaki Baba
- Department of Infectious Diseases, Internal Medicine, Tohoku University Graduate School of Medicine, 2-1 Seiryo-machi, Aoba-ku, Sendai 980-8574, Japan
| | - Mie Yoshida
- AMANO Co., Ltd., 275 Mamedocho, Kohoku-ku, Yokohama 222-8558, Japan
| | | | | | - Hiroki Sonehara
- Genome Clinic Co., Ltd., 2-5-1 Chuo, Chuo-ku, Chiba 260-0013, Japan
| | - Kazue Mizuno
- MRC LLC, 5-29-12, Hongo, Bunkyo-ku, Tokyo 113-0033, Japan
- Preferred Networks, Inc., 1-6-1 Otemachi Building, Otemachi, Chiyoda-ku, Tokyo 100-0004, Japan
| | - Hajime Kanamori
- Department of Infectious Diseases, Internal Medicine, Tohoku University Graduate School of Medicine, 2-1 Seiryo-machi, Aoba-ku, Sendai 980-8574, Japan
| | - Koichi Tokuda
- Department of Infectious Diseases, Internal Medicine, Tohoku University Graduate School of Medicine, 2-1 Seiryo-machi, Aoba-ku, Sendai 980-8574, Japan
| | - Atsuhiro Nakagawa
- Department of Neurosurgery, Tohoku University Graduate School of Medicine, 2-1 Seiryo-machi, Aoba-ku, Sendai 980-8574, Japan
| | - Akira Mizuno
- AMANO Co., Ltd., 275 Mamedocho, Kohoku-ku, Yokohama 222-8558, Japan
- MRC LLC, 5-29-12, Hongo, Bunkyo-ku, Tokyo 113-0033, Japan
| |
Collapse
|
18
|
de Rooij MM, Sikkema RS, Bouwknegt M, de Geus Y, Stanoeva KR, Nieuwenweg S, van Dam AS, Raben C, Dohmen W, Heederik D, Reusken C, Meijer A, Koopmans MP, Franz E, Smit LA. A Comprehensive Sampling Study on SARS-CoV-2 Contamination of Air and Surfaces in a Large Meat Processing Plant Experiencing COVID-19 Clusters in June 2020. J Occup Environ Med 2023; 65:e227-e233. [PMID: 36640441 PMCID: PMC10090283 DOI: 10.1097/jom.0000000000002785] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Abstract
OBJECTIVE We aimed to assess SARS-CoV-2 contamination of air and surfaces to gain insight into potential occupational exposure in a large meat processing plant experiencing COVID-19 clusters. Methods: Oro-nasopharyngeal SARS-CoV-2 screening was performed in 76 workers. Environmental samples ( n = 275) including air, ventilation systems, sewage, and swabs of high-touch surfaces and workers' hands were tested for SARS-CoV-2 RNA by real-time quantitative polymerase chain reaction. Results: Twenty-seven (35.5%) of the (predominantly asymptomatic) workers tested positive with modest to low viral loads (cycle threshold ≥ 29.7). Six of 203 surface swabs, 1 of 12 personal air samples, and one of four sewage samples tested positive; other samples tested negative. Conclusions: Although one third of workers tested positive, environmental contamination was limited. Widespread SARS-CoV-2 transmission via air and surfaces was considered unlikely within this plant at the time of investigation while strict COVID-19 control measures were already implemented.
Collapse
|
19
|
Desai G, Ramachandran G, Goldman E, Esposito W, Galione A, Lal A, Choueiri TK, Fay A, Jordan W, Schaffner DW, Caravanos J, Grignard E, Mainelis G. Efficacy of Grignard Pure to Inactivate Airborne Phage MS2, a Common SARS-CoV-2 Surrogate. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2023; 57:4231-4240. [PMID: 36853925 PMCID: PMC10001433 DOI: 10.1021/acs.est.2c08632] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Revised: 02/07/2023] [Accepted: 02/07/2023] [Indexed: 06/18/2023]
Abstract
Grignard Pure (GP) is a unique and proprietary blend of triethylene glycol (TEG) and inert ingredients designed for continuous antimicrobial treatment of air. TEG has been designated as a ″Safer Chemical" by the US EPA. GP has already received approval from the US EPA under its Section 18 Public Health Emergency Exemption program for use in seven states. This study characterizes the efficacy of GP for inactivating MS2 bacteriophage─a nonenveloped virus widely used as a surrogate for SARS-CoV-2. Experiments measured the decrease in airborne viable MS2 concentration in the presence of different concentrations of GP from 60 to 90 min, accounting for both natural die-off and settling of MS2. Experiments were conducted both by introducing GP aerosol into air containing MS2 and by introducing airborne MS2 into air containing GP aerosol. GP is consistently able to rapidly reduce viable MS2 bacteriophage concentration by 2-3 logs at GP concentrations of 0.04-0.5 mg/m3 (corresponding to TEG concentrations of 0.025 to 0.287 mg/m3). Related GP efficacy experiments by the US EPA, as well as GP (TEG) safety and toxicology, are also discussed.
Collapse
Affiliation(s)
- Grishma Desai
- Grignard
Company, LLC, Rahway, New Jersey 07065, United States
| | - Gurumurthy Ramachandran
- Department
of Environmental Health and Engineering, Johns Hopkins Education and
Research Center for Occupational Safety and Health, Bloomberg School
of Public Health, Whiting School of Engineering, The Johns Hopkins University, Baltimore, Maryland 21218, United States
| | - Emanuel Goldman
- Department
of Microbiology, Biochemistry, and Molecular Genetics, Rutgers-New Jersey Medical School, Newark, New Jersey 07103, United States
| | - William Esposito
- Founder, Ambient Group, Inc., New York, New York 10018, United States
| | - Antony Galione
- Department
of Pharmacology, University of Oxford, Oxford OX1 3QT, United Kingdom
| | - Altaf Lal
- Former Chief,
Molecular Vaccine Section, CDC. Former Health Attaché and HHS
Regional Representative for South Asia, Former US FDA Country Director
- India, Atlanta, Georgia 30345, United States
| | - Toni K. Choueiri
- Dana-Farber
Cancer Institute, Harvard Medical School, Boston, Massachusetts 02215, United States
| | - Andre Fay
- Pontifícia
Universidade Católica do Rio Grande do Sul, School of Medicine, Porto Alegre, Rio Grande
do Sul 90619-900, Brazil
| | - William Jordan
- Former Deputy
Director, Office of Pesticide Programs, Environmental Protection Agency, William Jordan Consulting, Washington, District of
Columbia 20016, United States
| | - Donald W. Schaffner
- Department
of Food Science, School of Environmental and Biological Sciences,
Rutgers, The State University of NJ, New Brunswick, New Jersey 08902, United States
| | - Jack Caravanos
- Clinical
Professor
of Environmental Public Health Services, New York University, New York, New York 10012, United States
| | - Etienne Grignard
- Founder, CEO, Grignard
Pure, LLC, Rahway, New Jersey 07065, United States
| | - Gediminas Mainelis
- Department
of Environmental Sciences, School of Environmental and Biological
Sciences, Rutgers, The State University
of NJ, New Brunswick, New Jersey 08901, United States
| |
Collapse
|
20
|
Raymenants J, Geenen C, Budts L, Thibaut J, Thijssen M, De Mulder H, Gorissen S, Craessaerts B, Laenen L, Beuselinck K, Ombelet S, Keyaerts E, André E. Indoor air surveillance and factors associated with respiratory pathogen detection in community settings in Belgium. Nat Commun 2023; 14:1332. [PMID: 36898982 PMCID: PMC10005919 DOI: 10.1038/s41467-023-36986-z] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2022] [Accepted: 02/27/2023] [Indexed: 03/12/2023] Open
Abstract
Currently, the real-life impact of indoor climate, human behaviour, ventilation and air filtration on respiratory pathogen detection and concentration are poorly understood. This hinders the interpretability of bioaerosol quantification in indoor air to surveil respiratory pathogens and transmission risk. We tested 341 indoor air samples from 21 community settings in Belgium for 29 respiratory pathogens using qPCR. On average, 3.9 pathogens were positive per sample and 85.3% of samples tested positive for at least one. Pathogen detection and concentration varied significantly by pathogen, month, and age group in generalised linear (mixed) models and generalised estimating equations. High CO2 and low natural ventilation were independent risk factors for detection. The odds ratio for detection was 1.09 (95% CI 1.03-1.15) per 100 parts per million (ppm) increase in CO2, and 0.88 (95% CI 0.80-0.97) per stepwise increase in natural ventilation (on a Likert scale). CO2 concentration and portable air filtration were independently associated with pathogen concentration. Each 100ppm increase in CO2 was associated with a qPCR Ct value decrease of 0.08 (95% CI -0.12 to -0.04), and portable air filtration with a 0.58 (95% CI 0.25-0.91) increase. The effects of occupancy, sampling duration, mask wearing, vocalisation, temperature, humidity and mechanical ventilation were not significant. Our results support the importance of ventilation and air filtration to reduce transmission.
Collapse
Affiliation(s)
- Joren Raymenants
- Laboratory of Clinical Microbiology, KU Leuven, Herestraat 49, 3000, Leuven, Belgium.
- Department of General Internal Medicine, University Hospitals Leuven, Herestraat 49, 3000, Leuven, Belgium.
| | - Caspar Geenen
- Laboratory of Clinical Microbiology, KU Leuven, Herestraat 49, 3000, Leuven, Belgium
| | - Lore Budts
- Department of Laboratory Medicine, National Reference Center of Respiratory Pathogens, University Hospitals Leuven, Herestraat 49, 3000, Leuven, Belgium
| | - Jonathan Thibaut
- Laboratory of Clinical Microbiology, KU Leuven, Herestraat 49, 3000, Leuven, Belgium
| | - Marijn Thijssen
- Laboratory of Clinical and Epidemiological Virology (Rega Institute), KU Leuven, Herestraat 49, 3000, Leuven, Belgium
| | - Hannelore De Mulder
- Laboratory of Clinical Microbiology, KU Leuven, Herestraat 49, 3000, Leuven, Belgium
| | - Sarah Gorissen
- Laboratory of Clinical Microbiology, KU Leuven, Herestraat 49, 3000, Leuven, Belgium
| | - Bastiaan Craessaerts
- Department of Laboratory Medicine, National Reference Center of Respiratory Pathogens, University Hospitals Leuven, Herestraat 49, 3000, Leuven, Belgium
| | - Lies Laenen
- Laboratory of Clinical Microbiology, KU Leuven, Herestraat 49, 3000, Leuven, Belgium
- Department of Laboratory Medicine, National Reference Center of Respiratory Pathogens, University Hospitals Leuven, Herestraat 49, 3000, Leuven, Belgium
| | - Kurt Beuselinck
- Department of Laboratory Medicine, National Reference Center of Respiratory Pathogens, University Hospitals Leuven, Herestraat 49, 3000, Leuven, Belgium
| | - Sien Ombelet
- Department of Laboratory Medicine, National Reference Center of Respiratory Pathogens, University Hospitals Leuven, Herestraat 49, 3000, Leuven, Belgium
| | - Els Keyaerts
- Department of Laboratory Medicine, National Reference Center of Respiratory Pathogens, University Hospitals Leuven, Herestraat 49, 3000, Leuven, Belgium
| | - Emmanuel André
- Laboratory of Clinical Microbiology, KU Leuven, Herestraat 49, 3000, Leuven, Belgium
- Department of Laboratory Medicine, National Reference Center of Respiratory Pathogens, University Hospitals Leuven, Herestraat 49, 3000, Leuven, Belgium
| |
Collapse
|
21
|
Groma V, Kugler S, Farkas Á, Füri P, Madas B, Nagy A, Erdélyi T, Horváth A, Müller V, Szántó-Egész R, Micsinai A, Gálffy G, Osán J. Size distribution and relationship of airborne SARS-CoV-2 RNA to indoor aerosol in hospital ward environments. Sci Rep 2023; 13:3566. [PMID: 36864124 PMCID: PMC9980870 DOI: 10.1038/s41598-023-30702-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Accepted: 02/28/2023] [Indexed: 03/04/2023] Open
Abstract
Aerosol particles proved to play a key role in airborne transmission of SARS-CoV-2 viruses. Therefore, their size-fractionated collection and analysis is invaluable. However, aerosol sampling in COVID departments is not straightforward, especially in the sub-500-nm size range. In this study, particle number concentrations were measured with high temporal resolution using an optical particle counter, and several 8 h daytime sample sets were collected simultaneously on gelatin filters with cascade impactors in two different hospital wards during both alpha and delta variants of concern periods. Due to the large number (152) of size-fractionated samples, SARS-CoV-2 RNA copies could be statistically analyzed over a wide range of aerosol particle diameters (70-10 µm). Our results revealed that SARS-CoV-2 RNA is most likely to exist in particles with 0.5-4 µm aerodynamic diameter, but also in ultrafine particles. Correlation analysis of particulate matter (PM) and RNA copies highlighted the importance of indoor medical activity. It was found that the daily maximum increment of PM mass concentration correlated the most with the number concentration of SARS-CoV-2 RNA in the corresponding size fractions. Our results suggest that particle resuspension from surrounding surfaces is an important source of SARS-CoV-2 RNA present in the air of hospital rooms.
Collapse
Affiliation(s)
- V Groma
- Environmental Physics Department, Centre for Energy Research, Budapest, 1121, Hungary
| | - Sz Kugler
- Environmental Physics Department, Centre for Energy Research, Budapest, 1121, Hungary
| | - Á Farkas
- Environmental Physics Department, Centre for Energy Research, Budapest, 1121, Hungary
| | - P Füri
- Environmental Physics Department, Centre for Energy Research, Budapest, 1121, Hungary
| | - B Madas
- Environmental Physics Department, Centre for Energy Research, Budapest, 1121, Hungary
| | - A Nagy
- Department of Applied and Nonlinear Optics, Wigner Research Centre for Physics, Budapest, 1121, Hungary
| | - T Erdélyi
- Department of Pulmonology, Semmelweis University, Budapest, 1085, Hungary
| | - A Horváth
- Department of Pulmonology, Semmelweis University, Budapest, 1085, Hungary
- Pest County Pulmonology Hospital, Törökbálint, 2045, Hungary
| | - V Müller
- Department of Pulmonology, Semmelweis University, Budapest, 1085, Hungary
| | | | | | - G Gálffy
- Pest County Pulmonology Hospital, Törökbálint, 2045, Hungary
| | - J Osán
- Environmental Physics Department, Centre for Energy Research, Budapest, 1121, Hungary.
| |
Collapse
|
22
|
Derk RC, Coyle JP, Lindsley WG, Blachere FM, Lemons AR, Service SK, Martin SB, Mead KR, Fotta SA, Reynolds JS, McKinney WG, Sinsel EW, Beezhold DH, Noti JD. Efficacy of Do-It-Yourself air filtration units in reducing exposure to simulated respiratory aerosols. BUILDING AND ENVIRONMENT 2023; 229:109920. [PMID: 36569517 PMCID: PMC9759459 DOI: 10.1016/j.buildenv.2022.109920] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/03/2022] [Revised: 12/03/2022] [Accepted: 12/12/2022] [Indexed: 05/20/2023]
Abstract
Many respiratory diseases, including COVID-19, can be spread by aerosols expelled by infected people when they cough, talk, sing, or exhale. Exposure to these aerosols indoors can be reduced by portable air filtration units (air cleaners). Homemade or Do-It-Yourself (DIY) air filtration units are a popular alternative to commercially produced devices, but performance data is limited. Our study used a speaker-audience model to examine the efficacy of two popular types of DIY air filtration units, the Corsi-Rosenthal cube and a modified Ford air filtration unit, in reducing exposure to simulated respiratory aerosols within a mock classroom. Experiments were conducted using four breathing simulators at different locations in the room, one acting as the respiratory aerosol source and three as recipients. Optical particle spectrometers monitored simulated respiratory aerosol particles (0.3-3 μm) as they dispersed throughout the room. Using two DIY cubes (in the front and back of the room) increased the air change rate as much as 12.4 over room ventilation, depending on filter thickness and fan airflow. Using multiple linear regression, each unit increase of air change reduced exposure by 10%. Increasing the number of filters, filter thickness, and fan airflow significantly enhanced the air change rate, which resulted in exposure reductions of up to 73%. Our results show DIY air filtration units can be an effective means of reducing aerosol exposure. However, they also show performance of DIY units can vary considerably depending upon their design, construction, and positioning, and users should be mindful of these limitations.
Collapse
Affiliation(s)
- Raymond C Derk
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, 1000 Fredrick Lane, Morgantown, WV, 26508, USA
| | - Jayme P Coyle
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, 1000 Fredrick Lane, Morgantown, WV, 26508, USA
| | - William G Lindsley
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, 1000 Fredrick Lane, Morgantown, WV, 26508, USA
| | - Francoise M Blachere
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, 1000 Fredrick Lane, Morgantown, WV, 26508, USA
| | - Angela R Lemons
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, 1000 Fredrick Lane, Morgantown, WV, 26508, USA
| | - Samantha K Service
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, 1000 Fredrick Lane, Morgantown, WV, 26508, USA
| | - Stephen B Martin
- Respiratory Health Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, 1000 Fredrick Lane, Morgantown, WV, 26505, USA
| | - Kenneth R Mead
- Division of Field Studies and Engineering, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Cincinnati, OH, 45226, USA
| | - Steven A Fotta
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, 1000 Fredrick Lane, Morgantown, WV, 26508, USA
| | - Jeffrey S Reynolds
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, 1000 Fredrick Lane, Morgantown, WV, 26508, USA
| | - Walter G McKinney
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, 1000 Fredrick Lane, Morgantown, WV, 26508, USA
| | - Erik W Sinsel
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, 1000 Fredrick Lane, Morgantown, WV, 26508, USA
| | - Donald H Beezhold
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, 1000 Fredrick Lane, Morgantown, WV, 26508, USA
| | - John D Noti
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, 1000 Fredrick Lane, Morgantown, WV, 26508, USA
| |
Collapse
|
23
|
Wiryasaputra R, Huang CY, Kristiani E, Liu PY, Yeh TK, Yang CT. Review of an intelligent indoor environment monitoring and management system for COVID-19 risk mitigation. Front Public Health 2023; 10:1022055. [PMID: 36703846 PMCID: PMC9871550 DOI: 10.3389/fpubh.2022.1022055] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2022] [Accepted: 12/23/2022] [Indexed: 01/12/2023] Open
Abstract
The coronavirus disease (COVID-19) outbreak has turned the world upside down bringing about a massive impact on society due to enforced measures such as the curtailment of personal travel and limitations on economic activities. The global pandemic resulted in numerous people spending their time at home, working, and learning from home hence exposing them to air contaminants of outdoor and indoor origins. COVID-19 is caused by the Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2), which spreads by airborne transmission. The viruses found indoors are linked to the building's ventilation system quality. The ventilation flow in an indoor environment controls the movement and advection of any aerosols, pollutants, and Carbon Dioxide (CO2) created by indoor sources/occupants; the quantity of CO2 can be measured by sensors. Indoor CO2 monitoring is a technique used to track a person's COVID-19 risk, but high or low CO2 levels do not necessarily mean that the COVID-19 virus is present in the air. CO2 monitors, in short, can help inform an individual whether they are breathing in clean air. In terms of COVID-19 risk mitigation strategies, intelligent indoor monitoring systems use various sensors that are available in the marketplace. This work presents a review of scientific articles that influence intelligent monitoring development and indoor environmental quality management system. The paper underlines that the non-dispersive infrared (NDIR) sensor and ESP8266 microcontroller support the development of low-cost indoor air monitoring at learning facilities.
Collapse
Affiliation(s)
- Rita Wiryasaputra
- Department of Industrial Engineering and Enterprise Information, Tunghai University, Taichung, Taiwan
- Department of Informatics, Krida Wacana Christian University, Jakarta, Indonesia
| | - Chin-Yin Huang
- Department of Industrial Engineering and Enterprise Information, Tunghai University, Taichung, Taiwan
| | - Endah Kristiani
- Department of Informatics, Krida Wacana Christian University, Jakarta, Indonesia
- Department of Computer Science, Tunghai University, Taichung, Taiwan
| | - Po-Yu Liu
- Division of Infection, Department of Internal Medicine, Taichung Veterans General Hospital, Taichung, Taiwan
- Ph.D. Program in Translational Medicine, National Chung Hsing University, Taichung, Taiwan
- Rong Hsing Research Center for Translational Medicine, National Chung Hsing University, Taichung, Taiwan
- Department of Post-Baccalaureate Medicine, College of Medicine, National Chung Hsing University, Taichung, Taiwan
- Genomic Center for Infectious Diseases, Taichung Veterans General Hospital, Taichung, Taiwan
| | - Ting-Kuang Yeh
- Division of Infection, Department of Internal Medicine, Taichung Veterans General Hospital, Taichung, Taiwan
- Genomic Center for Infectious Diseases, Taichung Veterans General Hospital, Taichung, Taiwan
| | - Chao-Tung Yang
- Department of Computer Science, Tunghai University, Taichung, Taiwan
- Research Center for Smart Sustainable Circular Economy, Tunghai University, Taichung, Taiwan
| |
Collapse
|
24
|
Singh T, Sharma N, Satakshi, Kumar M. Analysis and forecasting of air quality index based on satellite data. Inhal Toxicol 2023; 35:24-39. [PMID: 36602767 DOI: 10.1080/08958378.2022.2164388] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
OBJECTIVE The air quality index (AQI) forecasts are one of the most important aspects of improving urban public health and enabling society to remain sustainable despite the effects of air pollution. Pollution control organizations deploy ground stations to collect information about air pollutants. Establishing a ground station all-around is not feasible due to the cost involved. As an alternative, satellite-captured data can be utilized for AQI assessment. This study explores the changes in AQI during various COVID-19 lockdowns in India utilizing satellite data. Furthermore, it addresses the effectiveness of state-of-the-art deep learning and statistical approaches for forecasting short-term AQI. MATERIALS AND METHODS Google Earth Engine (GEE) has been utilized to capture the data for the study. The satellite data has been authenticated against ground station data utilizing the beta distribution test before being incorporated into the study. The AQI forecasting has been explored using state-of-the-art statistical and deep learning approaches like VAR, Holt-Winter, and LSTM variants (stacked, bi-directional, and vanilla). RESULTS AQI ranged from 100 to 300, from moderately polluted to very poor during the study period. The maximum reduction was recorded during the complete lockdown period in the year 2020. Short-term AQI forecasting with Holt-Winter was more accurate than other models with the lowest MAPE scores. CONCLUSIONS Based on our findings, air pollution is clearly a threat in the studied locations, and it is important for all stakeholders to work together to reduce it. The level of air pollutants dropped substantially during the different lockdowns.
Collapse
Affiliation(s)
- Tinku Singh
- Indian Institute of Information Technology Allahabad, Prayagraj, India
| | - Nikhil Sharma
- Indian Institute of Information Technology Allahabad, Prayagraj, India
| | | | - Manish Kumar
- Indian Institute of Information Technology Allahabad, Prayagraj, India
| |
Collapse
|
25
|
Kitagawa H, Nomura T, Kaiki Y, Kakimoto M, Nazmul T, Omori K, Shigemoto N, Sakaguchi T, Ohge H. Viable SARS-CoV-2 detected in the air of hospital rooms of patients with COVID-19 with an early infection. Int J Infect Dis 2023; 126:73-78. [PMID: 36356797 PMCID: PMC9640214 DOI: 10.1016/j.ijid.2022.11.003] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2022] [Revised: 10/31/2022] [Accepted: 11/03/2022] [Indexed: 11/09/2022] Open
Abstract
OBJECTIVES This study assessed the concentration of SARS-CoV-2 in the air of hospital rooms occupied by patients with COVID-19 who had viable SARS-CoV-2 in nasopharyngeal (NP) samples in early infection. METHODS Between July and October 2021, NP swabs were collected from 20 patients with early SARS-CoV-2 infection admitted to a tertiary hospital in Japan. Air samples were collected from their rooms, tested for SARS-CoV-2 RNA, and cultured to determine potential infectivity. RESULTS The NP swab samples of 18 patients were positive for viable SARS-CoV-2 (median concentration: 4.0 × 105 tissue culture infectious dose 50/ml). In the air samples, viral RNA (median concentration: 1.1 × 105 copies/m3) was detected in 12/18 (67%) patients, and viable virus (median concentration: 8.9 × 102 tissue culture infectious dose 50/m3) was detected in 5/18 (28%) patients. The median time between illness onset and sampling was 3 days. The RNA concentration was significantly higher in samples wherein viable SARS-CoV-2 was detected than in samples in which viable virus was not detected (P-value = 0.027). CONCLUSION Viable SARS-CoV-2 can be detected in the air surrounding patients with early SARS-CoV-2 infection. Health care workers should pay attention to infection control when caring for patients with early SARS-CoV-2 infection.
Collapse
Affiliation(s)
- Hiroki Kitagawa
- Department of Infectious Diseases, Hiroshima University Hospital, Hiroshima, Japan,Department of Surgery, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan,Corresponding author: Hiroki Kitagawa, Department of Infectious Diseases, Hiroshima University Hospital, Department of Surgery, Graduate School of Biomedical and Health Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan
| | - Toshihito Nomura
- Department of Infectious Diseases, Hiroshima University Hospital, Hiroshima, Japan,Department of Virology, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan
| | - Yuki Kaiki
- Department of Surgery, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan
| | - Masaki Kakimoto
- Department of General Internal Medicine, Hiroshima University Hospital, Hiroshima, Japan
| | - Tanuza Nazmul
- Department of Virology, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan
| | - Keitaro Omori
- Department of Infectious Diseases, Hiroshima University Hospital, Hiroshima, Japan
| | - Norifumi Shigemoto
- Department of Infectious Diseases, Hiroshima University Hospital, Hiroshima, Japan,Department of Surgery, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan,Translational Research Center, Hiroshima University, Hiroshima, Japan
| | - Takemasa Sakaguchi
- Department of Virology, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan
| | - Hiroki Ohge
- Department of Infectious Diseases, Hiroshima University Hospital, Hiroshima, Japan
| |
Collapse
|
26
|
Knobloch JK, Pfefferle S, Lütgehetmann M, Nörz D, Klupp EM, Belmar Campos CE, Kluge S, Aepfelbacher M, Knobling B, Franke G. Infectivity of SARS-CoV-2 on Inanimate Surfaces: Don't Trust Ct Value. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:17074. [PMID: 36554950 PMCID: PMC9779331 DOI: 10.3390/ijerph192417074] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/03/2022] [Revised: 12/08/2022] [Accepted: 12/16/2022] [Indexed: 06/17/2023]
Abstract
SARS-CoV-2 RNA is frequently identified in patient rooms and it was speculated that the viral load quantified by PCR might correlate with infectivity of surfaces. To evaluate Ct values for the prediction of infectivity, we investigated contaminated surfaces and Ct-value changes after disinfection. Viral RNA was detected on 37 of 143 investigated surfaces of an ICU. However, virus isolation failed for surfaces with a high viral RNA load. Also, SARS-CoV-2 could not be cultivated from surfaces artificially contaminated with patient specimens. In order to evaluate the significance of Ct values more precisely, we used surrogate enveloped bacteriophage Φ6. A strong reduction in Φ6 was achieved by three different disinfection methods. Despite a strong reduction in viability almost no change in the Ct values was observed for UV-C and alcoholic surface disinfectant. Disinfection using ozone resulted in a lack of Φ6 recovery as well as a detectable shift in Ct values indicating strong degradation of the viral RNA. The observed lack of significant effects on the detectable viral RNA after effective disinfection suggest that quantitative PCR is not suitable for predicting the infectivity of SARS-CoV-2 on inanimate surfaces. Ct values should therefore not be considered as markers for infectivity in this context.
Collapse
Affiliation(s)
- Johannes K. Knobloch
- Institute for Medical Microbiology, Virology and Hygiene, Department for Infection Prevention and Control, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246 Hamburg, Germany
| | - Susanne Pfefferle
- Institute for Medical Microbiology, Virology and Hygiene, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246 Hamburg, Germany
| | - Marc Lütgehetmann
- Institute for Medical Microbiology, Virology and Hygiene, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246 Hamburg, Germany
| | - Dominik Nörz
- Institute for Medical Microbiology, Virology and Hygiene, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246 Hamburg, Germany
| | - Eva M. Klupp
- Institute for Medical Microbiology, Virology and Hygiene, Department for Infection Prevention and Control, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246 Hamburg, Germany
| | - Cristina E. Belmar Campos
- Institute for Medical Microbiology, Virology and Hygiene, Department for Infection Prevention and Control, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246 Hamburg, Germany
| | - Stefan Kluge
- Department of Intensive Care Medicine, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246 Hamburg, Germany
| | - Martin Aepfelbacher
- Institute for Medical Microbiology, Virology and Hygiene, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246 Hamburg, Germany
| | - Birte Knobling
- Institute for Medical Microbiology, Virology and Hygiene, Department for Infection Prevention and Control, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246 Hamburg, Germany
| | - Gefion Franke
- Institute for Medical Microbiology, Virology and Hygiene, Department for Infection Prevention and Control, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246 Hamburg, Germany
| |
Collapse
|
27
|
Chaussade S, Pellat A, Corre F, Hallit R, Abou Ali E, Belle A, Barret M, Chaussade P, Coriat R. A new system to prevent SARS-CoV-2 and microorganism air transmission through the air circulation system of endoscopes. Endosc Int Open 2022; 10:E1589-E1594. [PMID: 36531679 PMCID: PMC9754862 DOI: 10.1055/a-1907-3939] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Accepted: 07/18/2022] [Indexed: 12/23/2022] Open
Abstract
Background and study aims Evidence for the modes of transmission of SARS-CoV-2 remains controversial. Recently, the potential for airborne spread of SARS-CoV-2 has been stressed. Air circulation in gastrointestinal light source boxes and endoscopes could be implicated in airborne transmission of microorganisms. Methods The ENDOBOX SC is a 600 × 600 mm cube designed to contain any type of machine used during gastrointestinal endoscopy. It allows for a 100-mm space between a machine and the walls of the ENDOBOX SC. To use the ENDOBOX SC, it is connected to the medical air system and it provides positive flow from the box to the endoscopy room. The ENDOBOX SC uses medical air to inflate the digestive tract and to decrease the temperature induced by the microprocessors or by the lamp. ENDOBOX SC has been investigated in different environments. Results An endoscopic procedure performed without ventilation was interrupted after 40 minutes to prevent computer damage. During the first 30 minutes, the temperature increased from 18 °C to 31 °C with a LED system. The procedure with fans identified variations in temperature inside the ENDOBOX SC from 21 to 26 °C (± 5 °C) 1 hour after the start of the procedure. The temperature was stable for the next 3 hours. Conclusions ENDOBOX SC prevents the increase in temperature induced by lamps and processors, allows access to all necessary connections into the endoscopic columns, and creates a sterile and positive pressure volume, which prevents potential contamination from microorganisms.
Collapse
Affiliation(s)
- Stanislas Chaussade
- Gastroenterology and Digestive Endoscopy Unit, Cochin University Hospital, Assistance Publique-Hôpitaux de Paris, Université de Paris, Paris, France
| | - Anna Pellat
- Gastroenterology and Digestive Endoscopy Unit, Cochin University Hospital, Assistance Publique-Hôpitaux de Paris, Université de Paris, Paris, France
| | - Felix Corre
- Gastroenterology and Digestive Endoscopy Unit, Cochin University Hospital, Assistance Publique-Hôpitaux de Paris, Université de Paris, Paris, France
| | - Rachel Hallit
- Gastroenterology and Digestive Endoscopy Unit, Cochin University Hospital, Assistance Publique-Hôpitaux de Paris, Université de Paris, Paris, France
| | - Einas Abou Ali
- Gastroenterology and Digestive Endoscopy Unit, Cochin University Hospital, Assistance Publique-Hôpitaux de Paris, Université de Paris, Paris, France
| | - Arthur Belle
- Gastroenterology and Digestive Endoscopy Unit, Cochin University Hospital, Assistance Publique-Hôpitaux de Paris, Université de Paris, Paris, France
| | - Maximilien Barret
- Gastroenterology and Digestive Endoscopy Unit, Cochin University Hospital, Assistance Publique-Hôpitaux de Paris, Université de Paris, Paris, France
| | - Paul Chaussade
- Gastroenterology and Digestive Endoscopy Unit, Cochin University Hospital, Assistance Publique-Hôpitaux de Paris, Université de Paris, Paris, France
| | - Romain Coriat
- Gastroenterology and Digestive Endoscopy Unit, Cochin University Hospital, Assistance Publique-Hôpitaux de Paris, Université de Paris, Paris, France
| |
Collapse
|
28
|
Chen YY, Shen X, Wang YJ, Xie JW, Fang ZX, Lin LR, Yang TC. Evaluation of the cycle threshold values of RT-PCR for SARS-CoV-2 in COVID-19 patients in predicting epidemic dynamics and monitoring surface contamination. J Infect Public Health 2022; 15:1494-1496. [PMID: 36413872 PMCID: PMC9671601 DOI: 10.1016/j.jiph.2022.11.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2022] [Revised: 10/20/2022] [Accepted: 11/10/2022] [Indexed: 11/18/2022] Open
Abstract
To evaluate the application of cycle threshold (Ct) values of coronavirus disease 2019 (COVID-19) patients in predicting epidemic dynamics and monitoring surface contamination. The Ct value of reverse transcriptase-polymerase chain reaction for SARS‑CoV-2 from COVID-19 patients inbound overseas in Xiamen, China was collected from October 2020 to December 2021, and the correlation of patients' Ct values with epidemic dynamics and surface contamination was evaluated. The results showed that there was an extreme inverse correlation of positivity rate in the current calendar month (ORF1ab, r = -0.692, P = 0.004; N,r = -0.629, P = 0.012) and the following calendar month (ORF1ab,r = -0.801, P = 0.001; N,r = -0.620, P = 0.018) with the median Ct values. Ct value showed better performance for monitoring surface contamination, with the area under the curve value 0.808(95 %CI: 0.748-0.869) for ORF1ab and 0.807(95 %CI:0.746-0.868) for the N gene. The patients' ORF1ab Ct value< 29.09 or N Ct value< 28.03 were 11.25 times and 10.48 times more likely to result in surface contamination than those with ORF1ab Ct value ≥ 29.09 or N Ct value≥ 28.03 (OR:11.25,95 % CI: 5.52-22.35; OR:10.48,95 % CI:5.29-20.70). Ct values were associated with the positivity rate in the current or following calendar month and predicted the epidemic dynamics. The Ct values can be used as a predictor for monitoring surface contamination to develop public health responses to COVID-19.
Collapse
Affiliation(s)
- Yu-Yan Chen
- Center of Clinical Laboratory, Zhongshan Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, China,Institute of Infectious Disease, School of Medicine, Xiamen University, Xiamen, China
| | - Xu Shen
- Center of Clinical Laboratory, Zhongshan Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, China,Institute of Infectious Disease, School of Medicine, Xiamen University, Xiamen, China,Department of Hospital Infection Management, Zhongshan Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, China
| | - Yong-Jing Wang
- Center of Clinical Laboratory, Zhongshan Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, China,Institute of Infectious Disease, School of Medicine, Xiamen University, Xiamen, China
| | - Jia-Wen Xie
- Center of Clinical Laboratory, Zhongshan Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, China,Institute of Infectious Disease, School of Medicine, Xiamen University, Xiamen, China,Xiamen Medical College, Xiamen, China
| | - Zan-Xi Fang
- Center of Clinical Laboratory, Zhongshan Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, China,Institute of Infectious Disease, School of Medicine, Xiamen University, Xiamen, China,Xiamen Medical College, Xiamen, China
| | - Li-Rong Lin
- Center of Clinical Laboratory, Zhongshan Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, China,Institute of Infectious Disease, School of Medicine, Xiamen University, Xiamen, China,Xiamen Medical College, Xiamen, China,Corresponding authors at: Center of Clinical Laboratory, Zhongshan Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, China
| | - Tian-Ci Yang
- Center of Clinical Laboratory, Zhongshan Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, China,Institute of Infectious Disease, School of Medicine, Xiamen University, Xiamen, China,Corresponding authors at: Center of Clinical Laboratory, Zhongshan Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, China
| |
Collapse
|
29
|
Qi Y, Chen Y, Yan X, Liu W, Ma L, Liu Y, Ma Q, Liu S. Co-Exposure of Ambient Particulate Matter and Airborne Transmission Pathogens: The Impairment of the Upper Respiratory Systems. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2022; 56:15892-15901. [PMID: 36240448 PMCID: PMC9670849 DOI: 10.1021/acs.est.2c03856] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/30/2022] [Revised: 10/04/2022] [Accepted: 10/04/2022] [Indexed: 06/16/2023]
Abstract
Recent evidence has pinpointed the positive relevance between air particulate matter (PM) pollution and epidemic spread. However, there are still significant knowledge gaps in understanding the transmission and infection of pathogens loaded on PMs, for example, the interactions between pathogens and pre-existing atmospheric PM and the health effects of co-exposure on the inhalation systems. Here, we unraveled the interactions between fine particulate matter (FPM) and Pseudomonas aeruginosa (P. aeruginosa) and evaluated the infection and detrimental effects of co-exposure on the upper respiratory systems in both in vitro and in vivo models. We uncovered the higher accessibility and invasive ability of pathogens to epithelial cells after loading on FPMs, compared with the single exposure. Furthermore, we designed a novel laboratory exposure model to simulate a real co-exposure scenario. Intriguingly, the co-exposure induced more serious functional damage and longer inflammatory reactions to the upper respiratory tract, including the nasal cavity and trachea. Collectively, our results provide a new point of view on the transmission and infection of pathogens loaded on FPMs and uncover the in vivo systematic impairments of the inhalation tract under co-exposure through a novel laboratory exposure model. Hence, this study sheds light on further investigations of the detrimental effects of air pollution and epidemic spread.
Collapse
Affiliation(s)
- Yu Qi
- State
Key Laboratory of Environmental Chemistry and Ecotoxicology, Research
Center for Eco-Environmental Sciences, Chinese
Academy of Sciences, 18 Shuangqing Road, Haidian District, Beijing 100085, China
- College
of Resources and Environment, University
of Chinese Academy of Sciences, Beijing 100049, China
| | - Yucai Chen
- State
Key Laboratory of Environmental Chemistry and Ecotoxicology, Research
Center for Eco-Environmental Sciences, Chinese
Academy of Sciences, 18 Shuangqing Road, Haidian District, Beijing 100085, China
- College
of Resources and Environment, University
of Chinese Academy of Sciences, Beijing 100049, China
| | - Xu Yan
- State
Key Laboratory of Environmental Chemistry and Ecotoxicology, Research
Center for Eco-Environmental Sciences, Chinese
Academy of Sciences, 18 Shuangqing Road, Haidian District, Beijing 100085, China
- College
of Resources and Environment, University
of Chinese Academy of Sciences, Beijing 100049, China
| | - Wei Liu
- State
Key Laboratory of Environmental Chemistry and Ecotoxicology, Research
Center for Eco-Environmental Sciences, Chinese
Academy of Sciences, 18 Shuangqing Road, Haidian District, Beijing 100085, China
- College
of Resources and Environment, University
of Chinese Academy of Sciences, Beijing 100049, China
| | - Li Ma
- Aerosol
and Haze Laboratory, Advanced Innovation Center for Soft Matter Science
and Engineering, Beijing University of Chemical
Technology, Beijing 100029, China
| | - Yongchun Liu
- Aerosol
and Haze Laboratory, Advanced Innovation Center for Soft Matter Science
and Engineering, Beijing University of Chemical
Technology, Beijing 100029, China
| | - Qingxin Ma
- State
Key Laboratory of Environmental Chemistry and Ecotoxicology, Research
Center for Eco-Environmental Sciences, Chinese
Academy of Sciences, 18 Shuangqing Road, Haidian District, Beijing 100085, China
- College
of Resources and Environment, University
of Chinese Academy of Sciences, Beijing 100049, China
| | - Sijin Liu
- State
Key Laboratory of Environmental Chemistry and Ecotoxicology, Research
Center for Eco-Environmental Sciences, Chinese
Academy of Sciences, 18 Shuangqing Road, Haidian District, Beijing 100085, China
- College
of Resources and Environment, University
of Chinese Academy of Sciences, Beijing 100049, China
| |
Collapse
|
30
|
Oksanen L, Auvinen M, Kuula J, Malmgren R, Romantschuk M, Hyvärinen A, Laitinen S, Maunula L, Sanmark E, Geneid A, Sofieva S, Salokas J, Veskiväli H, Sironen T, Grönholm T, Hellsten A, Atanasova N. Combining Phi6 as a surrogate virus and computational large-eddy simulations to study airborne transmission of SARS-CoV-2 in a restaurant. INDOOR AIR 2022; 32:e13165. [PMID: 36437671 PMCID: PMC10100099 DOI: 10.1111/ina.13165] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/17/2022] [Revised: 09/30/2022] [Accepted: 10/08/2022] [Indexed: 05/18/2023]
Abstract
COVID-19 has highlighted the need for indoor risk-reduction strategies. Our aim is to provide information about the virus dispersion and attempts to reduce the infection risk. Indoor transmission was studied simulating a dining situation in a restaurant. Aerosolized Phi6 viruses were detected with several methods. The aerosol dispersion was modeled by using the Large-Eddy Simulation (LES) technique. Three risk-reduction strategies were studied: (1) augmenting ventilation with air purifiers, (2) spatial partitioning with dividers, and (3) combination of 1 and 2. In all simulations infectious viruses were detected throughout the space proving the existence long-distance aerosol transmission indoors. Experimental cumulative virus numbers and LES dispersion results were qualitatively similar. The LES results were further utilized to derive the evolution of infection probability. Air purifiers augmenting the effective ventilation rate by 65% reduced the spatially averaged infection probability by 30%-32%. This relative reduction manifests with approximately 15 min lag as aerosol dispersion only gradually reaches the purifier units. Both viral findings and LES results confirm that spatial partitioning has a negligible effect on the mean infection-probability indoors, but may affect the local levels adversely. Exploitation of high-resolution LES jointly with microbiological measurements enables an informative interpretation of the experimental results and facilitates a more complete risk assessment.
Collapse
Affiliation(s)
- Lotta Oksanen
- Department of Otorhinolaryngology and Phoniatrics – Head and Neck SurgeryHelsinki University HospitalHelsinkiFinland
- Faculty of MedicineUniversity of HelsinkiHelsinkiFinland
| | | | - Joel Kuula
- Finnish Meteorological InstituteHelsinkiFinland
| | - Rasmus Malmgren
- Faculty of Biological and Environmental SciencesUniversity of HelsinkiHelsinkiFinland
| | - Martin Romantschuk
- Faculty of Biological and Environmental SciencesUniversity of HelsinkiHelsinkiFinland
- Faculty of Biological and Environmental SciencesUniversity of HelsinkiLahtiFinland
| | | | | | - Leena Maunula
- Faculty of Veterinary Medicine, Food Hygiene and Environmental HealthUniversity of HelsinkiHelsinkiFinland
| | - Enni Sanmark
- Department of Otorhinolaryngology and Phoniatrics – Head and Neck SurgeryHelsinki University HospitalHelsinkiFinland
- Faculty of MedicineUniversity of HelsinkiHelsinkiFinland
| | - Ahmed Geneid
- Department of Otorhinolaryngology and Phoniatrics – Head and Neck SurgeryHelsinki University HospitalHelsinkiFinland
- Faculty of MedicineUniversity of HelsinkiHelsinkiFinland
| | - Svetlana Sofieva
- Finnish Meteorological InstituteHelsinkiFinland
- Faculty of Biological and Environmental SciencesUniversity of HelsinkiHelsinkiFinland
| | - Julija Salokas
- Faculty of Biological and Environmental SciencesUniversity of HelsinkiHelsinkiFinland
| | - Helin Veskiväli
- Faculty of Biological and Environmental SciencesUniversity of HelsinkiHelsinkiFinland
| | - Tarja Sironen
- Department of Virology, Faculty of MedicineUniversity of HelsinkiHelsinkiFinland
- Department of Veterinary Biosciences, Faculty of Veterinary MedicineUniversity of HelsinkiHelsinkiFinland
| | | | | | - Nina Atanasova
- Finnish Meteorological InstituteHelsinkiFinland
- Faculty of Biological and Environmental SciencesUniversity of HelsinkiHelsinkiFinland
| |
Collapse
|
31
|
Zeng G, Chen L, Yuan H, Yamamoto A, Chen H, Maruyama S. Analysis of airborne sputum droplets flow dynamic behaviors under different ambient conditions and aerosol size effects. CHEMOSPHERE 2022; 307:135708. [PMID: 35850221 PMCID: PMC9283082 DOI: 10.1016/j.chemosphere.2022.135708] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/05/2022] [Revised: 07/04/2022] [Accepted: 07/11/2022] [Indexed: 06/15/2023]
Abstract
The coronavirus (COVID-19) is becoming more threatening with the emergence of new mutations. New virus transmission and infection processes remain challenging and re-examinations of proper protection methods are urgently needed. From fluid dynamic viewpoint, the transmission of virus-carrying droplets and aerosols is one key to understanding the virus-transmission mechanisms. This study shows virus transmission by incorporating flow-evaporation model into the Navier-Stokes equation to describe the group of airborne sputum droplets exhaled under Rosin-Rammler distribution. Solid components and humidity field evolution are incorporated in describing droplet and ambient conditions. The numerical model is solved by an inhouse code using advection-diffusion equation for the temperature field and the humidity field, discretized by applying the total-variation diminishing Runge-Kutta method. The results of this study are presented in detail to show the different trends under various ambient conditions and to reveal the major viral-transmission routes as a function of droplet size.
Collapse
Affiliation(s)
- Gang Zeng
- Institute of Engineering Thermophysics, Chinese Academy of Sciences, Beijing, 100190, China; School of Mathematics and Computational Science, Xiangtan University, Xiangtan, 411105, China
| | - Lin Chen
- Institute of Engineering Thermophysics, Chinese Academy of Sciences, Beijing, 100190, China; University of Chinese Academy of Sciences, Beijing, 100049, China; Innovation Academy for Light-duty Gas Turbine, Chinese Academy of Sciences, Beijing, 100190, China.
| | - Haizhuan Yuan
- School of Mathematics and Computational Science, Xiangtan University, Xiangtan, 411105, China
| | - Ayumi Yamamoto
- National Institute of Technology, Hachinohe College, Hachinohe, Aomori, 039-1192, Japan
| | - Haisheng Chen
- Institute of Engineering Thermophysics, Chinese Academy of Sciences, Beijing, 100190, China; University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Shigenao Maruyama
- National Institute of Technology, Hachinohe College, Hachinohe, Aomori, 039-1192, Japan
| |
Collapse
|
32
|
SARS-CoV-2 in the Air Surrounding Patients during Nebulizer Therapy. CANADIAN JOURNAL OF INFECTIOUS DISEASES AND MEDICAL MICROBIOLOGY 2022; 2022:9297974. [PMID: 36213437 PMCID: PMC9536972 DOI: 10.1155/2022/9297974] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Revised: 08/05/2022] [Accepted: 08/29/2022] [Indexed: 11/19/2022]
Abstract
Nebulizer therapy is commonly used for patients with obstructive pulmonary disease or acute pulmonary infections with signs of obstruction. It is considered a “potential aerosol-generating procedure,” and the risk of disease transmission to health care workers is uncertain. The aim of this pilot study was to assess whether nebulizer therapy in hospitalized COVID-19 patients is associated with increased dispersion of SARS-CoV-2. Air samples collected prior to and during nebulizer therapy were analyzed by RT-PCR and cell culture. Total aerosol particle concentrations were also quantified. Of 13 patients, seven had quantifiable virus in oropharynx samples, and only two had RT-PCR positive air samples. For both these patients, air samples collected during nebulizer therapy had higher SARS-CoV-2 RNA concentrations compared to control air samples. Also, for particle sizes 0.3–5 µm, particle concentrations were significantly higher during nebulizer therapy than in controls. We were unable to cultivate virus from any of the RT-PCR positive air samples, and it is therefore unknown if the detected virus were replication-competent; however, the significant increase in smaller particles, which can remain airborne for extended periods of time, and increased viral RNA concentrations during treatment may indicate that nebulizer therapy is associated with increased risk of SARS-CoV-2 transmission.
Collapse
|
33
|
Wong YJ, Shiu HY, Chang JHH, Ooi MCG, Li HH, Homma R, Shimizu Y, Chiueh PT, Maneechot L, Nik Sulaiman NM. Spatiotemporal impact of COVID-19 on Taiwan air quality in the absence of a lockdown: Influence of urban public transportation use and meteorological conditions. JOURNAL OF CLEANER PRODUCTION 2022; 365:132893. [PMID: 35781986 PMCID: PMC9234473 DOI: 10.1016/j.jclepro.2022.132893] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/19/2021] [Revised: 06/01/2022] [Accepted: 06/24/2022] [Indexed: 05/19/2023]
Abstract
The unprecedented outbreak of COVID-19 significantly improved the atmospheric environment for lockdown-imposed regions; however, scant evidence exists on its impacts on regions without lockdown. A novel research framework is proposed to evaluate the long-term monthly spatiotemporal impact of COVID-19 on Taiwan air quality through different statistical analyses, including geostatistical analysis, change detection analysis and identification of nonattainment pollutant occurrence between the average mean air pollutant concentrations from 2018-2019 and 2020, considering both meteorological and public transportation impacts. Contrary to lockdown-imposed regions, insignificant or worsened air quality conditions were observed at the beginning of COVID-19, but a delayed improvement occurred after April in Taiwan. The annual mean concentrations of PM10, PM2.5, SO2, NO2, CO and O3 in 2020 were reduced by 24%, 18%, 15%, 9.6%, 7.4% and 1.3%, respectively (relative to 2018-2019), and the overall occurrence frequency of nonattainment air pollutants declined by over 30%. Backward stepwise regression models for each air pollutant were successfully constructed utilizing 12 meteorological parameters (R2 > 0.8 except for SO2) to simulate the meteorological normalized business-as-usual concentration. The hybrid single-particle Lagrangian integrated trajectory (HYSPLIT) model simulated the fate of air pollutants (e.g., local emissions or transboundary pollution) for anomalous months. The changes in different public transportation usage volumes (e.g., roadway, railway, air, and waterway) moderately reduced air pollution, particularly CO and NO2. Reduced public transportation use had a more significant impact than meteorology on air quality improvement in Taiwan, highlighting the importance of proper public transportation management for air pollution control and paving a new path for sustainable air quality management even in the absence of a lockdown.
Collapse
Affiliation(s)
- Yong Jie Wong
- Research Center for Environmental Quality Management, Graduate School of Engineering, Kyoto University, 520-0811, Japan
| | - Huan-Yu Shiu
- Graduate Institute of Environmental Engineering, National Taiwan University, 10617, Taiwan
| | - Jackson Hian-Hui Chang
- Department of Atmospheric Sciences, National Central University, 32001, Taiwan
- Preparatory Center for Science and Technology (PPST), Universiti Malaysia Sabah, 88400, Malaysia
| | - Maggie Chel Gee Ooi
- Institute of Climate Change, National University of Malaysia (UKM), Bangi, 43600, Malaysia
| | - Hsueh-Hsun Li
- Graduate Institute of Environmental Engineering, National Taiwan University, 10617, Taiwan
| | - Ryosuke Homma
- Research Center for Environmental Quality Management, Graduate School of Engineering, Kyoto University, 520-0811, Japan
| | - Yoshihisa Shimizu
- Research Center for Environmental Quality Management, Graduate School of Engineering, Kyoto University, 520-0811, Japan
| | - Pei-Te Chiueh
- Graduate Institute of Environmental Engineering, National Taiwan University, 10617, Taiwan
| | - Luksanaree Maneechot
- Environmental Engineering and Disaster Management Program, School of Interdisciplinary Studies, Mahidol University Kanchanaburi Campus (MUKA), Kanchanaburi, 71150, Thailand
| | - Nik Meriam Nik Sulaiman
- Department of Chemical Engineering, Faculty of Engineering, University of Malaya, 50603, Kuala Lumpur, Malaysia
| |
Collapse
|
34
|
Joan TV, Kristiyan SA, Ernest SL, Nuria TP, Herme GB, Josep MB. Efficiency and sensitivity optimization of a protocol to quantify indoor airborne SARS-CoV-2 levels. J Hosp Infect 2022; 130:44-51. [PMID: 36100140 PMCID: PMC9465472 DOI: 10.1016/j.jhin.2022.08.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2022] [Revised: 08/24/2022] [Accepted: 08/26/2022] [Indexed: 11/29/2022]
Abstract
Background Development of methodologies to quantify airborne micro-organisms is needed for the prevention and control of infections. It is difficult to conclude which is the most efficient and sensitive strategy to assess airborne SARS-CoV-2 RNA levels due to the disparity of results reported in clinical settings. Aim To improve our previously reported protocol of measuring SARS-CoV-2 RNA levels, which was based on bioaerosol collection with a liquid impinger and RNA quantification with droplet digital polymerase chain reaction (ddPCR). Methods Air samples were collected in COVID-19 patient rooms to assess efficiency and/or sensitivity of different air samplers, liquid collection media, and reverse transcriptases (RT). Findings Mineral oil retains airborne RNA better than does hydrophilic media without impairing integrity. SARS-CoV-2 ORF1ab target was detected in 80% of the air samples using BioSampler with mineral oil. No significant differences in effectiveness were obtained with MD8 sampler equipped with gelatine membrane filters, but the SARS-CoV-2 copies/m3 air obtained with the latter were lower (28.4 ± 6.1 vs 9 ± 1.7). SuperScript II RT allows the detection of a single SARS-CoV-2 genome RNA molecule by ddPCR with high efficiency. This was the only RT that allowed the detection of SARS-CoV-2 N1 target in air samples. Conclusion The collection efficiency and detection sensivity of a protocol to quantify SARS-CoV-2 RNA levels in indoor air has been improved in the present study. Such optimization is important to improve our understanding of the microbiological safety of indoor air.
Collapse
Affiliation(s)
- Truyols-Vives Joan
- Molecular Biology and One Health Research Group (MolONE), Universitat de Les Illes Balears (UIB), Palma, Spain
| | | | - Sala-Llinàs Ernest
- Molecular Biology and One Health Research Group (MolONE), Universitat de Les Illes Balears (UIB), Palma, Spain; Health Research Institute of the Balearic Islands (IdISBa), Balearic Islands, Spain; Department of Pulmonary Medicine, Hospital Universitari Son Espases (HUSE), Balearic Islands, Spain; Biomedical Research Networking Center on Respiratory Diseases (CIBERES), Madrid, Spain
| | - Toledo-Pons Nuria
- Health Research Institute of the Balearic Islands (IdISBa), Balearic Islands, Spain; Department of Pulmonary Medicine, Hospital Universitari Son Espases (HUSE), Balearic Islands, Spain
| | - G Baldoví Herme
- Department of Chemistry, Universitat Politècnica de València (UPV)
| | - Mercader-Barceló Josep
- Molecular Biology and One Health Research Group (MolONE), Universitat de Les Illes Balears (UIB), Palma, Spain; Health Research Institute of the Balearic Islands (IdISBa), Balearic Islands, Spain.
| |
Collapse
|
35
|
Siebler L, Calandri M, Rathje T, Stergiaropoulos K. Experimental Methods of Investigating Airborne Indoor Virus-Transmissions Adapted to Several Ventilation Measures. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:11300. [PMID: 36141572 PMCID: PMC9517214 DOI: 10.3390/ijerph191811300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Revised: 08/31/2022] [Accepted: 09/03/2022] [Indexed: 06/16/2023]
Abstract
This study introduces a principle that unifies two experimental methods for evaluating airborne indoor virus-transmissions adapted to several ventilation measures. A first-time comparison of mechanical/natural ventilation and air purification with regard to infection risks is enabled. Effortful computational fluid dynamics demand detailed boundary conditions for accurate calculations of indoor airflows, which are often unknown. Hence, a suitable, simple and generalized experimental set up for identifying the spatial and temporal infection risk for different ventilation measures is more qualified even with unknown boundary conditions. A trace gas method is suitable for mechanical and natural ventilation with outdoor air exchange. For an accurate assessment of air purifiers based on filtration, a surrogate particle method is appropriate. The release of a controlled rate of either trace gas or particles simulates an infectious person releasing virus material. Surrounding substance concentration measurements identify the neighborhood exposure. One key aspect of the study is to prove that the requirement of concordant results of both methods is fulfilled. This is the only way to ensure that the comparison of different ventilation measures described above is reliable. Two examples (a two-person office and a classroom) show how practical both methods are and how the principle is applicable for different types and sizes of rooms.
Collapse
|
36
|
Del Real Á, Expósito A, Ruiz-Azcona L, Santibáñez M, Fernández-Olmo I. SARS-CoV-2 surveillance in indoor and outdoor size-segregated aerosol samples. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2022; 29:62973-62983. [PMID: 35449331 PMCID: PMC9023038 DOI: 10.1007/s11356-022-20237-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/09/2022] [Accepted: 04/09/2022] [Indexed: 05/13/2023]
Abstract
We aimed to determine the presence of SARS-CoV-2 RNA in indoor and outdoor size-segregated aerosol samples (PM10-2.5, PM2.5). Five outdoor daily samples were collected between November and December 2020 in an urban/industrial area with relatively high PM10 levels (Maliaño, Santander, Spain) by using a PM impactor (air flowrate of 30 L/min). In a non-hospital indoor sampling surveillance context, 8 samples in classrooms and 6 samples in the central library-Paraninfo of the University of Cantabria (UC) were collected between April and June 2021 by using personal PM samplers (air flowrate of 3 L/min). Lastly, 8 samples in the pediatric nasopharyngeal testing room at Liencres Hospital, 6 samples from different single occupancy rooms of positive patients, and 2 samples in clinical areas of the COVID plant of the University Hospital Marqués de Valdecilla (HUMV) were collected between January and May 2021. N1, N2 genes were used to test the presence of SARS-CoV-2 RNA by RT-qPCR. SARS-CoV-2 positive detection was only obtained from one fine fraction (PM2.5) sample, corresponding to one occupancy room, where a patient with positive PCR and cough was present. Negative results found in other sampling areas such as the pediatric nasopharyngeal testing rooms should be interpreted in terms of air sampling volume limitation and good ventilation.
Collapse
Affiliation(s)
- Álvaro Del Real
- Medicine and Psychiatry Department, Universidad de Cantabria, Av. Cardenal Herrera Oria, s/n, 39011, Santander, Cantabria, Spain
| | - Andrea Expósito
- Departamento de Ingenierías Química y Biomolecular, Universidad de Cantabria, Avda. Los Castros S/N, 39005, Santander, Cantabria, Spain
| | - Laura Ruiz-Azcona
- Global Health Research Group. Dpto Enfermería, Universidad de Cantabria, Avda. Valdecilla, s/n, 39008, Santander, Cantabria, Spain
| | - Miguel Santibáñez
- Global Health Research Group. Dpto Enfermería, Universidad de Cantabria, Avda. Valdecilla, s/n, 39008, Santander, Cantabria, Spain
- Nursing Research Group, IDIVAL, Calle Cardenal Herrera Oria s/n, 39011, Santander, Cantabria, Spain
| | - Ignacio Fernández-Olmo
- Departamento de Ingenierías Química y Biomolecular, Universidad de Cantabria, Avda. Los Castros S/N, 39005, Santander, Cantabria, Spain.
| |
Collapse
|
37
|
Huang W, Wang K, Hung CT, Chow KM, Tsang D, Lai RWM, Xu RH, Yeoh EK, Ho KF, Chen C. Evaluation of SARS-CoV-2 transmission in COVID-19 isolation wards: On-site sampling and numerical analysis. JOURNAL OF HAZARDOUS MATERIALS 2022; 436:129152. [PMID: 35739698 PMCID: PMC9106403 DOI: 10.1016/j.jhazmat.2022.129152] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Revised: 05/06/2022] [Accepted: 05/11/2022] [Indexed: 05/29/2023]
Abstract
Although airborne transmission has been considered as a possible route for the spread of SARS-CoV-2, the role that aerosols play in SARS-CoV-2 transmission is still controversial. This study evaluated the airborne transmission of SARS-CoV-2 in COVID-19 isolation wards at Prince of Wales Hospital in Hong Kong by both on-site sampling and numerical analysis. A total of 838 air samples and 1176 surface samples were collected, and SARS-CoV-2 RNA was detected using the RT-PCR method. Testing revealed that 2.3% of the air samples and 9.3% of the surface samples were positive, indicating that the isolation wards were contaminated with the virus. The dispersion and deposition of exhaled particles in the wards were calculated by computational fluid dynamics (CFD) simulations. The calculated accumulated number of particles collected at the air sampling points was closely correlated with the SARS-CoV-2 positive rates from the field sampling, which confirmed the possibility of airborne transmission. Furthermore, three potential intervention strategies, i.e., the use of curtains, ceiling-mounted air cleaners, and periodic ventilation, were numerically investigated to explore effective control measures in isolation wards. According to the results, the use of ceiling-mounted air cleaners is effective in reducing the airborne transmission of SARS-CoV-2 in such wards.
Collapse
Affiliation(s)
- Wenjie Huang
- Department of Mechanical and Automation Engineering, The Chinese University of Hong Kong, Shatin, N.T. 999077, Hong Kong, China
| | - Kailu Wang
- The Jockey Club School of Public Health and Primary Care, The Chinese University of Hong Kong, Shatin, N.T. 999077, Hong Kong, China; Centre for Health Systems and Policy Research, JCSPHPC, The Chinese University of Hong Kong, Shatin, N.T. 999077, Hong Kong, China
| | - Chi-Tim Hung
- The Jockey Club School of Public Health and Primary Care, The Chinese University of Hong Kong, Shatin, N.T. 999077, Hong Kong, China; Centre for Health Systems and Policy Research, JCSPHPC, The Chinese University of Hong Kong, Shatin, N.T. 999077, Hong Kong, China
| | - Kai-Ming Chow
- Department of Medicine and Therapeutics, Prince of Wales Hospital, Shatin, N.T. 999077, Hong Kong, China
| | - Dominic Tsang
- Public Health Laboratory Centre, Centre for Health Protection, Kowloon 999077, Hong Kong, China
| | - Raymond Wai-Man Lai
- Department of Microbiology, Prince of Wales Hospital, Shatin, N.T. 999077, Hong Kong, China
| | - Richard Huan Xu
- Department of Rehabilitation Science, Faculty of Health and Social Science, The Hong Kong Polytechnic University, Kowloon 999077, Hong Kong, China
| | - Eng-Kiong Yeoh
- The Jockey Club School of Public Health and Primary Care, The Chinese University of Hong Kong, Shatin, N.T. 999077, Hong Kong, China; Centre for Health Systems and Policy Research, JCSPHPC, The Chinese University of Hong Kong, Shatin, N.T. 999077, Hong Kong, China
| | - Kin-Fai Ho
- The Jockey Club School of Public Health and Primary Care, The Chinese University of Hong Kong, Shatin, N.T. 999077, Hong Kong, China.
| | - Chun Chen
- Department of Mechanical and Automation Engineering, The Chinese University of Hong Kong, Shatin, N.T. 999077, Hong Kong, China; Shenzhen Research Institute, The Chinese University of Hong Kong, Shenzhen 518057, China.
| |
Collapse
|
38
|
Park J, Lee KS, Park H. Optimized mechanism for fast removal of infectious pathogen-laden aerosols in the negative-pressure unit. JOURNAL OF HAZARDOUS MATERIALS 2022; 435:128978. [PMID: 35472540 PMCID: PMC9020843 DOI: 10.1016/j.jhazmat.2022.128978] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/26/2022] [Revised: 04/09/2022] [Accepted: 04/18/2022] [Indexed: 05/07/2023]
Abstract
It has been frequently emphasized that highly contagious respiratory disease pathogens (such as SARS-CoV-2) are transmitted to the other hosts in the form of micro-sized aerosols (< 5 μm) in the air without physical contacts. Hospital environments such as negative-pressure unit are considered being consistently exposed to pathogens, so it is essential to quickly discharge them through the effective ventilation system. To achieve that, in the present study, we propose the optimized ventilation mechanism and design for the fastest removal of pathogen-laden aerosol using numerical simulations. We quantitatively evaluated the aerosol removal performance of various ventilation configurations (combinations of air exhaust and supply ducts), and found that the key mechanism is to form the coherent (preferentially upward) airflow structure to surround the respiratory flow containing the aerosol cluster. We believe that the present findings will play a critical role in developing the high-efficiency negative-pressure facility irrespective of its size and environments.
Collapse
Affiliation(s)
- Jooyeon Park
- Department of Mechanical Engineering, Seoul National University, Seoul 08826, South Korea
| | - Kwang Suk Lee
- Department of Urology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul 06273, South Korea
| | - Hyungmin Park
- Department of Mechanical Engineering, Seoul National University, Seoul 08826, South Korea; Institute of Advanced Machines and Design, Seoul National University, Seoul 08826, South Korea.
| |
Collapse
|
39
|
Silva PG, Branco PTBS, Soares RRG, Mesquita JR, Sousa SIV. SARS-CoV-2 air sampling: A systematic review on the methodologies for detection and infectivity. INDOOR AIR 2022; 32:e13083. [PMID: 36040285 PMCID: PMC9538005 DOI: 10.1111/ina.13083] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/23/2022] [Revised: 07/06/2022] [Accepted: 07/08/2022] [Indexed: 06/15/2023]
Abstract
This systematic review aims to present an overview of the current aerosol sampling methods (and equipment) being used to investigate the presence of SARS-CoV-2 in the air, along with the main parameters reported in the studies that are essential to analyze the advantages and disadvantages of each method and perspectives for future research regarding this mode of transmission. A systematic literature review was performed on PubMed/MEDLINE, Web of Science, and Scopus to assess the current air sampling methodologies being applied to SARS-CoV-2. Most of the studies took place in indoor environments and healthcare settings and included air and environmental sampling. The collection mechanisms used were impinger, cyclone, impactor, filters, water-based condensation, and passive sampling. Most of the reviewed studies used RT-PCR to test the presence of SARS-CoV-2 RNA in the collected samples. SARS-CoV-2 RNA was detected with all collection mechanisms. From the studies detecting the presence of SARS-CoV-2 RNA, fourteen assessed infectivity. Five studies detected viable viruses using impactor, water-based condensation, and cyclone collection mechanisms. There is a need for a standardized protocol for sampling SARS-CoV-2 in air, which should also account for other influencing parameters, including air exchange ratio in the room sampled, relative humidity, temperature, and lighting conditions.
Collapse
Affiliation(s)
- Priscilla G Silva
- Laboratory for Integrative and Translational Research in Population Health (ITR), Porto, Portugal
- School of Medicine and Biomedical Sciences (ICBAS), University of Porto, Porto, Portugal
- LEPABE - Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Porto, Portugal
- ALiCE - Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, Porto, Portugal
- Epidemiology Research Unit (EPI Unit), Institute of Public Health, University of Porto, Porto, Portugal
| | - Pedro T B S Branco
- LEPABE - Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Porto, Portugal
- ALiCE - Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, Porto, Portugal
| | - Ruben R G Soares
- Department of Biochemistry and Biophysics, Science for Life Laboratory, Stockholm University, Solna, Sweden
- Division of Nanobiotechnology, Department of Protein Science, Science for Life Laboratory, KTH Royal Institute of Technology, Solna, Sweden
| | - João R Mesquita
- Laboratory for Integrative and Translational Research in Population Health (ITR), Porto, Portugal
- Epidemiology Research Unit (EPI Unit), Institute of Public Health, University of Porto, Porto, Portugal
| | - Sofia I V Sousa
- LEPABE - Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Porto, Portugal
- ALiCE - Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, Porto, Portugal
| |
Collapse
|
40
|
Moharir SC, Thota SC, Goel A, Thakur B, Tandel D, Reddy SM, Vodapalli A, Singh Bhalla G, Kumar D, Singh Naruka D, Kumar A, Tuli A, Suravaram S, Chander Bingi T, Srinivas M, Mesipogu R, Reddy K, Khosla S, Harshan KH, Bharadwaj Tallapaka K, Mishra RK. Detection of SARS-CoV-2 in the air in Indian hospitals and houses of COVID-19 patients. JOURNAL OF AEROSOL SCIENCE 2022; 164:106002. [PMID: 35495416 PMCID: PMC9040488 DOI: 10.1016/j.jaerosci.2022.106002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/19/2022] [Revised: 04/14/2022] [Accepted: 04/17/2022] [Indexed: 05/05/2023]
Abstract
To understand the transmission characteristics of severe acute respiratory syndrome corona virus-2 (SARS-CoV-2) through air, samples from different locations occupied by coronavirus disease (COVID-19) patients were analyzed. Three sampling strategies were used to understand the presence of virus in the air in different environmental conditions. In the first strategy, which involved hospital settings, air samples were collected from several areas of hospitals like COVID-intensive-care units (ICUs), nurse-stations, COVID-wards, corridors, non-COVID-wards, personal protective equipment (PPE) doffing areas, COVID rooms, out-patient (OP) corridors, mortuary, COVID casualty areas, non-COVID ICUs and doctors' rooms. Out of the 80 air samples collected from 6 hospitals from two Indian cities- Hyderabad and Mohali, 30 samples showed the presence of SARS-CoV-2 nucleic acids. In the second sampling strategy, that involved indoor settings, one or more COVID-19 patients were asked to spend a short duration of time in a closed room. Out of 17 samples, 5 samples, including 4 samples collected after the departure of three symptomatic patients from the room, showed the presence of SARS-CoV-2 nucleic acids. In the third strategy, involving indoor settings, air samples were collected from rooms of houses of home-quarantined COVID-19 patients and it was observed that SARS-CoV-2 RNA could be detected in the air in the rooms occupied by COVID-19 patients but not in the other rooms of the houses. Taken together, we observed that the air around COVID-19 patients frequently showed the presence of SARS-CoV-2 RNA in both hospital and indoor residential settings and the positivity rate was higher when 2 or more COVID-19 patients occupied the room. In hospitals, SARS-CoV-2 RNA could be detected in ICUs as well as in non-ICUs, suggesting that the viral shedding happened irrespective of the severity of the infection. This study provides evidence for the viability of SARS-CoV-2 and its long-range transport through the air. Thus, airborne transmission could be a major mode of transmission for SARS-CoV-2 and appropriate precautions need to be followed to prevent the spread of infection through the air.
Collapse
Affiliation(s)
- Shivranjani C Moharir
- CSIR- Centre for Cellular and Molecular Biology (CSIR-CCMB), Hyderabad, 500007, India
- The Tata Institute for Genetics and Society, Bangalore, 560065, India
| | - Sharath Chandra Thota
- CSIR- Centre for Cellular and Molecular Biology (CSIR-CCMB), Hyderabad, 500007, India
| | - Arushi Goel
- CSIR- Institute of Microbial Technology (CSIR-IMTech), Chandigarh, 160036, India
| | - Bhuwaneshwar Thakur
- CSIR- Institute of Microbial Technology (CSIR-IMTech), Chandigarh, 160036, India
| | - Dixit Tandel
- CSIR- Centre for Cellular and Molecular Biology (CSIR-CCMB), Hyderabad, 500007, India
| | - S Mahesh Reddy
- CSIR- Centre for Cellular and Molecular Biology (CSIR-CCMB), Hyderabad, 500007, India
| | - Amareshwar Vodapalli
- CSIR- Centre for Cellular and Molecular Biology (CSIR-CCMB), Hyderabad, 500007, India
| | | | - Dinesh Kumar
- CSIR- Institute of Microbial Technology (CSIR-IMTech), Chandigarh, 160036, India
| | | | - Ashwani Kumar
- CSIR- Institute of Microbial Technology (CSIR-IMTech), Chandigarh, 160036, India
| | - Amit Tuli
- CSIR- Institute of Microbial Technology (CSIR-IMTech), Chandigarh, 160036, India
| | | | | | - M Srinivas
- ESI Hospital and Medical College, Hyderabad, 500018, India
| | | | - Krishna Reddy
- Durgabai Deshmukh Hospital, Hyderabad, 500044, India
| | - Sanjeev Khosla
- CSIR- Institute of Microbial Technology (CSIR-IMTech), Chandigarh, 160036, India
| | - Krishnan H Harshan
- CSIR- Centre for Cellular and Molecular Biology (CSIR-CCMB), Hyderabad, 500007, India
| | | | - Rakesh K Mishra
- CSIR- Centre for Cellular and Molecular Biology (CSIR-CCMB), Hyderabad, 500007, India
- The Tata Institute for Genetics and Society, Bangalore, 560065, India
| |
Collapse
|
41
|
Azizi Jalilian F, Poormohammadi A, Teimoori A, Ansari N, Tarin Z, Ghorbani Shahna F, Azarian G, Leili M, Samarghandi M, Motaghed M, Nili Ahmadabadi A, Hassanvand MS. Evaluation of SARS-CoV-2 in Indoor Air of Sina and Shahid Beheshti Hospitals and Patients' Houses. FOOD AND ENVIRONMENTAL VIROLOGY 2022; 14:190-198. [PMID: 35212948 PMCID: PMC8872858 DOI: 10.1007/s12560-022-09515-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/19/2021] [Accepted: 02/09/2022] [Indexed: 06/14/2023]
Abstract
Side by side air sampling was conducted using a PTFE filter membrane as dry sampler and an impinger containing a suitable culture medium as a wet sampler. Most of the samples were collected from two hospitals and few air samples were collected from private houses of non-hospitalized confirmed COVID-19 patients. The collected air samples were analyzed using RT-PCR. The results indicated that all air samples collected from the hospitals were PCR negative for SARS-CoV-2. While two of four air samples collected from the house of non-hospitalized patients were PCR positive. In this study, most of the hospitalized patients had oxygen mask and face mask, and hence this may be a reason for our negative results regarding the presence of SARS-CoV-2 in indoor air of the hospitals, while non-hospitalized patients did not wear oxygen and protective face masks in their houses. Moreover, a very high concentration of particles in the size range of droplet nuclei (< 5 µm) was identified compared to particles in the size range of respiratory droplets (> 5-10 µm) in the areas where patients were hospitalized. It can be concluded that using face mask by patients can prevent the release of viruses into the indoor air, even in hospitals with a high density of patients.
Collapse
Affiliation(s)
- Farid Azizi Jalilian
- Department of Virology, Faculty of Medicine, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Ali Poormohammadi
- Department of Occupational Health Engineering, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran
- Center of Excellence for Occupational Health, Occupational Health and Safety Research Center, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Ali Teimoori
- Department of Virology, Faculty of Medicine, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Nastaran Ansari
- Department of Virology, Faculty of Medicine, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Zahra Tarin
- Department of Occupational Health Engineering, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Farshid Ghorbani Shahna
- Center of Excellence for Occupational Health, Occupational Health and Safety Research Center, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Ghasem Azarian
- Department of Environmental Health Engineering, School of Public Health and Research Center for Health Sciences, Hamadan University of Medical Sciences, Shaheed Fahmideh Ave., 6517838695, Hamadan, Iran
| | - Mostafa Leili
- Department of Environmental Health Engineering, School of Public Health and Research Center for Health Sciences, Hamadan University of Medical Sciences, Shaheed Fahmideh Ave., 6517838695, Hamadan, Iran.
| | - Mohammadreza Samarghandi
- Department of Environmental Health Engineering, School of Public Health and Research Center for Health Sciences, Hamadan University of Medical Sciences, Shaheed Fahmideh Ave., 6517838695, Hamadan, Iran
| | - Mahyar Motaghed
- Department of Neurology, Faculty of Medicine, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Amir Nili Ahmadabadi
- Department of Pharmacology and Toxicology, School of Pharmacy, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Mohammad Sadegh Hassanvand
- Centre for Air Pollution Research (CAPR), Institute for Environmental Research (IER), Tehran University of Medical Sciences, Tehran, Iran
- Department of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
42
|
Cheng VCC, Lung DC, Wong SC, Au AKW, Wang Q, Chen H, Xin L, Chu AWH, Ip JD, Chan WM, Tsoi HW, Tse H, Ng KHL, Kwan MYW, Chuang SK, To KKW, Li Y, Yuen KY. Outbreak investigation of airborne transmission of Omicron (B.1.1.529) - SARS-CoV-2 variant of concern in a restaurant: Implication for enhancement of indoor air dilution. JOURNAL OF HAZARDOUS MATERIALS 2022; 430:128504. [PMID: 35739650 PMCID: PMC8848576 DOI: 10.1016/j.jhazmat.2022.128504] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/17/2022] [Revised: 02/06/2022] [Accepted: 02/13/2022] [Indexed: 05/06/2023]
Abstract
Airborne transmission of SARS-CoV-2 has been increasingly recognized in the outbreak of COVID-19, especially with the Omicron variant. We investigated an outbreak due to Omicron variant in a restaurant. Besides epidemiological and phylogenetic analyses, the secondary attack rates of customers of restaurant-related COVID-19 outbreak before (Outbreak R1) and after enhancement of indoor air dilution (Outbreak R2) were compared. On 27th December 2021, an index case stayed in restaurant R2 for 98 min. Except for 1 sitting in the same table, six other secondary cases sat in 3 corners at 3 different zones, which were served by different staff. The median exposure time was 34 min (range: 19-98 min). All 7 secondary cases were phylogenetically related to the index. Smoke test demonstrated that the airflow direction may explain the distribution of secondary cases. Compared with an earlier COVID-19 outbreak in another restaurant R1 (19th February 2021), which occurred prior to the mandatory enhancement of indoor air dilution, the secondary attack rate among customers in R2 was significantly lower than that in R1 (3.4%, 7/207 vs 28.9%, 22/76, p<0.001). Enhancement of indoor air dilution through ventilation and installation of air purifier could minimize the risk of SARS-CoV-2 transmission in the restaurants.
Collapse
Affiliation(s)
- Vincent Chi-Chung Cheng
- Infection Control Team, Queen Mary Hospital, Hong Kong West Cluster, Hong Kong Special Administrative Region, China; Department of Microbiology, Queen Mary Hospital, Hong Kong Special Administrative Region, China
| | - David Christopher Lung
- Department of Pathology, Queen Elizabeth Hospital, Hong Kong Special Administrative Region, China
| | - Shuk-Ching Wong
- Infection Control Team, Queen Mary Hospital, Hong Kong West Cluster, Hong Kong Special Administrative Region, China
| | - Albert Ka-Wing Au
- Centre for Health Protection, Department of Health, Hong Kong Special Administrative Region, China
| | - Qun Wang
- Department of Mechanical Engineering, The University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Hong Chen
- Centre for Health Protection, Department of Health, Hong Kong Special Administrative Region, China
| | - Li Xin
- Department of Microbiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Allen Wing-Ho Chu
- Department of Microbiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Jonathan Daniel Ip
- Department of Microbiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Wan-Mui Chan
- Department of Microbiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Hoi-Wah Tsoi
- Department of Microbiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Herman Tse
- Department of Pathology, Hong Kong Children's Hospital, Hong Kong Special Administrative Region, China
| | - Ken Ho-Leung Ng
- Centre for Health Protection, Department of Health, Hong Kong Special Administrative Region, China
| | - Mike Yat-Wah Kwan
- Department of Paediatrics and Adolescent Medicine, Princess Margaret Hospital, Hong Kong Special Administrative Region, China
| | - Shuk-Kwan Chuang
- Centre for Health Protection, Department of Health, Hong Kong Special Administrative Region, China
| | - Kelvin Kai-Wang To
- Department of Microbiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Yuguo Li
- Department of Mechanical Engineering, The University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Kwok-Yung Yuen
- Department of Microbiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong Special Administrative Region, China.
| |
Collapse
|
43
|
Li F, Liu S, Huang H, Tan B. Impact of Occupational Risks of Medical Staff on Willingness to Occupational Mobility in COVID-19 Pandemic. Risk Manag Healthc Policy 2022; 15:685-702. [PMID: 35465135 PMCID: PMC9022743 DOI: 10.2147/rmhp.s360892] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Accepted: 04/11/2022] [Indexed: 11/23/2022] Open
Abstract
Purpose Medical staff are a crucial resource in the battle against the COVID-19 pandemic but are vulnerable to both SARS-CoV-2 infection and negative psychological outcomes. This study evaluated medical staff’s occupational risks, professional identity, and occupational mobility intention during the pandemic. Patients and Methods The questionnaire was anonymous. All respondents were Chinese medical personnel. Results Our findings suggest that the professional risks faced by medical professionals can enhance their professional mobility willingness and weaken their professional identity. They cannot only directly enhance their professional mobility willingness but also indirectly strengthen their professional mobility willingness through professional identity. The objective support and subjective support obtained by medical professionals cannot only alleviate the negative impact of occupational risk on professional identity alone but also jointly, and in the process of their joint mitigation, the former has been internalized and absorbed, while the latter has a stronger mitigation effect. The objective support and subjective support obtained by medical professionals can neither alone nor jointly alleviate the direct and positive impact of occupational risk on the willingness of occupational mobility. Conclusion The occupational risks faced by medical personnel can improve their willingness to move professionally and weaken their occupational identity. Early screening of high-risk groups for turnover intention among health care workers and more psychosocial health care and physical protection are needed during the COVID-19 pandemic in China.
Collapse
Affiliation(s)
- Fuda Li
- Business School, Hunan Normal University, Changsha, People’s Republic of China
| | - Shuang Liu
- Business School, Hunan Normal University, Changsha, People’s Republic of China
| | - Huaqian Huang
- Guangdong Polytechnic of Industry and Commerce, Guangzhou, People’s Republic of China
- Correspondence: Huaqian Huang, Guangdong Polytechnic of Industry and Commerce, Guangzhou, Guangdong Province, 510510, People’s Republic of China, Tel +86 18022122203, Email
| | - Bangzhe Tan
- Business School, Hunan Normal University, Changsha, People’s Republic of China
| |
Collapse
|
44
|
Myers NT, Laumbach RJ, Black KG, Ohman‐Strickland P, Alimokhtari S, Legard A, De Resende A, Calderón L, Lu FT, Mainelis G, Kipen HM. Portable air cleaners and residential exposure to SARS-CoV-2 aerosols: A real-world study. INDOOR AIR 2022; 32:e13029. [PMID: 35481935 PMCID: PMC9111720 DOI: 10.1111/ina.13029] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/09/2022] [Revised: 03/22/2022] [Accepted: 04/02/2022] [Indexed: 05/04/2023]
Abstract
Individuals with COVID-19 who do not require hospitalization are instructed to self-isolate in their residences. Due to high secondary infection rates in household members, there is a need to understand airborne transmission of SARS-CoV-2 within residences. We report the first naturalistic intervention study suggesting a reduction of such transmission risk using portable air cleaners (PACs) with HEPA filters. Seventeen individuals with newly diagnosed COVID-19 infection completed this single-blind, crossover, randomized study. Total and size-fractionated aerosol samples were collected simultaneously in the self-isolation room with the PAC (primary) and another room (secondary) for two consecutive 24-h periods, one period with HEPA filtration and the other with the filter removed (sham). Seven out of sixteen (44%) air samples in primary rooms were positive for SARS-CoV-2 RNA during the sham period. With the PAC operated at its lowest setting (clean air delivery rate [CADR] = 263 cfm) to minimize noise, positive aerosol samples decreased to four out of sixteen residences (25%; p = 0.229). A slight decrease in positive aerosol samples was also observed in the secondary room. As the world confronts both new variants and limited vaccination rates, our study supports this practical intervention to reduce the presence of viral aerosols in a real-world setting.
Collapse
Affiliation(s)
- Nirmala T. Myers
- Department of Environmental SciencesRutgers UniversityNew BrunswickNew JerseyUSA
- Rutgers Environmental and Occupational Health Sciences InstituteRutgers UniversityPiscatawayNew JerseyUSA
| | - Robert J. Laumbach
- Rutgers Environmental and Occupational Health Sciences InstituteRutgers UniversityPiscatawayNew JerseyUSA
- Department of Environmental and Occupational Health and JusticeRutgers UniversityPiscatawayNew JerseyUSA
| | - Kathleen G. Black
- Rutgers Environmental and Occupational Health Sciences InstituteRutgers UniversityPiscatawayNew JerseyUSA
| | - Pamela Ohman‐Strickland
- Rutgers Environmental and Occupational Health Sciences InstituteRutgers UniversityPiscatawayNew JerseyUSA
- Department of Biostatistics and EpidemiologyRutgers School of Public HealthRutgers UniversityPiscatawayNew JerseyUSA
| | - Shahnaz Alimokhtari
- Rutgers Environmental and Occupational Health Sciences InstituteRutgers UniversityPiscatawayNew JerseyUSA
| | - Alicia Legard
- Rutgers Environmental and Occupational Health Sciences InstituteRutgers UniversityPiscatawayNew JerseyUSA
| | - Adriana De Resende
- Rutgers Environmental and Occupational Health Sciences InstituteRutgers UniversityPiscatawayNew JerseyUSA
| | - Leonardo Calderón
- Department of Environmental SciencesRutgers UniversityNew BrunswickNew JerseyUSA
- Rutgers Environmental and Occupational Health Sciences InstituteRutgers UniversityPiscatawayNew JerseyUSA
| | - Frederic T. Lu
- Rutgers Environmental and Occupational Health Sciences InstituteRutgers UniversityPiscatawayNew JerseyUSA
| | - Gediminas Mainelis
- Department of Environmental SciencesRutgers UniversityNew BrunswickNew JerseyUSA
- Rutgers Environmental and Occupational Health Sciences InstituteRutgers UniversityPiscatawayNew JerseyUSA
| | - Howard M. Kipen
- Rutgers Environmental and Occupational Health Sciences InstituteRutgers UniversityPiscatawayNew JerseyUSA
- Department of Environmental and Occupational Health and JusticeRutgers UniversityPiscatawayNew JerseyUSA
| |
Collapse
|
45
|
Thylefors J, Thuresson S, Alsved M, Widell A, Fraenkel CJ, Löndahl J, Medstrand P, Senneby E. Detection of SARS-CoV-2 RNA on surfaces in a COVID-19 hospital ward indicates airborne viral spread. J Hosp Infect 2022; 124:121-122. [PMID: 35283226 PMCID: PMC8912984 DOI: 10.1016/j.jhin.2022.02.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Revised: 02/24/2022] [Accepted: 02/28/2022] [Indexed: 11/28/2022]
|
46
|
Thuresson S, Fraenkel CJ, Sasinovich S, Soldemyr J, Widell A, Medstrand P, Alsved M, Löndahl J. Airborne SARS-CoV-2 in hospitals - effects of aerosol-generating procedures, HEPA-filtration units, patient viral load and physical distance. Clin Infect Dis 2022; 75:e89-e96. [PMID: 35226740 PMCID: PMC9383519 DOI: 10.1093/cid/ciac161] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2021] [Indexed: 12/20/2022] Open
Abstract
BACKGROUND Transmission of covid-19 can occur through inhalation of fine droplets or aerosols containing infectious virus. The objective of this study was to identify situations, patient characteristics, environmental parameters and aerosol-generating procedures (AGPs) associated with airborne SARS-CoV-2 virus. METHODS Air samples were collected near hospitalised covid-19 patients and analysed by RT-qPCR. Results were related to distance to the patient, most recent patient diagnostic PCR Ct-value, room ventilation and ongoing potential AGP. RESULTS In total 310 air samples were collected, and of these 26 (8%) were positive. Of the 231 samples from patient rooms, 22 (10%) were positive for SARS-CoV-2. Positive air samples were associated with a low patient Ct-value (OR 5.0 for a Ct-value <25 vs >25, p=0.01, 95% confidence interval 1.18 to 29.5) and a shorter physical distance to the patient (OR 2.0 for every meter closer to the patient, p=0.05, CI 1.0 to 3.8). A mobile HEPA-filtration unit in the room decreased the proportion of positive samples (OR 0.3, p=0.02, CI 0.12 to 0.98). No association was observed between SARS-CoV-2 positive air samples and mechanical ventilation, high flow nasal cannula, nebulizer treatment or non-invasive ventilation. An association was found with positive expiratory pressure (PEP) training (p<0.01) and a trend towards association for airway manipulation, including bronchoscopies and in- and extubations. CONCLUSIONS Our results show that major risk factors for airborne SARS-CoV-2 include short physical distance, high patient viral load and poor room ventilation. AGPs, as traditionally defined, seem to be of secondary importance.
Collapse
Affiliation(s)
- Sara Thuresson
- Division of Ergonomics and Aerosol Technology, Department of Design Sciences, Lund University, Lund, Sweden
| | - Carl-Johan Fraenkel
- Department of Infection Control, Region Skåne, Lund, Sweden.,Division of Infection Medicine, Department of Clinical Sciences, Lund University, Lund, Sweden
| | | | - Jonathan Soldemyr
- Division of Ergonomics and Aerosol Technology, Department of Design Sciences, Lund University, Lund, Sweden
| | - Anders Widell
- Department of Translational Medicine, Lund University, Lund, Sweden
| | - Patrik Medstrand
- Department of Translational Medicine, Lund University, Lund, Sweden
| | - Malin Alsved
- Division of Ergonomics and Aerosol Technology, Department of Design Sciences, Lund University, Lund, Sweden
| | - Jakob Löndahl
- Division of Ergonomics and Aerosol Technology, Department of Design Sciences, Lund University, Lund, Sweden
| |
Collapse
|
47
|
SARS-CoV-2 RNA Recovery from Air Sampled on Quartz Fiber Filters: A Matter of Sample Preservation? ATMOSPHERE 2022. [DOI: 10.3390/atmos13020340] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/10/2022]
Abstract
The airborne route of transmission of SARS-CoV-2 was confirmed by the World Health Organization in April 2021. There is an urge to establish standardized protocols for assessing the concentration of SARS-CoV-2 RNA in air samples to support risk assessment, especially in indoor environments. Debates on the airborne transmission route of SARS-CoV-2 have been complicated because, among the studies testing the presence of the virus in the air, the percentage of positive samples has often been very low. In the present study, we report preliminary results on a study for the evaluation of parameters that can influence SARS-CoV-2 RNA recovery from quartz fiber filters spotted either by standard single-stranded SARS-CoV-2 RNA or by inactivated SARS-CoV-2 virions. The analytes were spiked on filters and underwent an active or passive sampling; then, they were preserved at −80 °C for different numbers of days (0 to 54) before extraction and analysis. We found a mean recovery of 2.43%, except for the sample not preserved (0 days) that showed a recovery of 13.51%. We found a relationship between the number of days and the recovery percentage. The results presented show a possible issue that relates to the quartz matrix and SARS-CoV-2 RNA recovery. The results are in accordance with the already published studies that described similar methods for SARS-CoV-2 RNA field sampling and that reported non-detectable concentrations of RNA. These outcomes could be false negatives due to sample preservation conditions. Thus, until further investigation, we suggest, as possible alternatives, to keep the filters: (i) in a sealed container for preservation at 4 °C; and (ii) in a viral transport medium for preservation at a temperature below 0 °C.
Collapse
|
48
|
Gohli J, Anderson AM, Brantsæter AB, Bøifot KO, Grub C, Hadley CL, Lind A, Pettersen ES, Søraas AVL, Dybwad M. Dispersion of SARS-CoV-2 in air surrounding COVID-19-infected individuals with mild symptoms. INDOOR AIR 2022; 32:e13001. [PMID: 35225394 PMCID: PMC9111593 DOI: 10.1111/ina.13001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/14/2021] [Revised: 01/21/2022] [Accepted: 01/29/2022] [Indexed: 06/14/2023]
Abstract
Since the beginning of the pandemic, the transmission modes of SARS-CoV-2-particularly the role of aerosol transmission-have been much debated. Accumulating evidence suggests that SARS-CoV-2 can be transmitted by aerosols, and not only via larger respiratory droplets. In this study, we quantified SARS-CoV-2 in air surrounding 14 test subjects in a controlled setting. All subjects had SARS-CoV-2 infection confirmed by a recent positive PCR test and had mild symptoms when included in the study. RT-PCR and cell culture analyses were performed on air samples collected at distances of one, two, and four meters from test subjects. Oronasopharyngeal samples were taken from consenting test subjects and analyzed by RT-PCR. Additionally, total aerosol particles were quantified during air sampling trials. Air viral concentrations at one-meter distance were significantly correlated with both viral loads in the upper airways, mild coughing, and fever. One sample collected at four-meter distance was RT-PCR positive. No samples were successfully cultured. The results reported here have potential application for SARS-CoV-2 detection and monitoring schemes, and for increasing our understanding of SARS-CoV-2 transmission dynamics. Practical implications. In this study, quantification of SARS-CoV-2 in air was performed around infected persons with mild symptoms. Such persons may go longer before they are diagnosed and may thus be a disproportionately important epidemiological group. By correlating viral concentrations in air with behavior and symptoms, we identify potential risk factors for viral dissemination in indoor environments. We also show that quantification of total aerosol particles is not a useful strategy for monitoring SARS-CoV-2 in indoor environments.
Collapse
Affiliation(s)
- Jostein Gohli
- Norwegian Defence Research EstablishmentKjellerNorway
| | | | - Arne Broch Brantsæter
- Department of Infectious DiseasesNorwegian National Unit for CBRNE MedicineOslo University HospitalNydalenNorway
| | - Kari Oline Bøifot
- Norwegian Defence Research EstablishmentKjellerNorway
- Department of AnalyticsEnvironmental & Forensic SciencesKing’s College LondonLondonUK
| | - Carola Grub
- Institute of microbiologyNorwegian Armed Forces Joint Medical ServicesKjellerNorway
| | | | | | | | | | - Marius Dybwad
- Norwegian Defence Research EstablishmentKjellerNorway
- Department of AnalyticsEnvironmental & Forensic SciencesKing’s College LondonLondonUK
| |
Collapse
|
49
|
Wong SC, Au AKW, Chen H, Yuen LLH, Li X, Lung DC, Chu AWH, Ip JD, Chan WM, Tsoi HW, To KKW, Yuen KY, Cheng VCC. Transmission of Omicron (B.1.1.529) - SARS-CoV-2 Variant of Concern in a designated quarantine hotel for travelers: a challenge of elimination strategy of COVID-19. THE LANCET REGIONAL HEALTH. WESTERN PACIFIC 2021; 18:100360. [PMID: 34961854 PMCID: PMC8696199 DOI: 10.1016/j.lanwpc.2021.100360] [Citation(s) in RCA: 43] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
Affiliation(s)
- Shuk-Ching Wong
- Infection Control Team, Queen Mary Hospital, Hong Kong West Cluster, Hong Kong Special Administrative Region, China
| | - Albert Ka-Wing Au
- Centre for Health Protection, Department of Health, Hong Kong Special Administrative Region, China
| | - Hong Chen
- Centre for Health Protection, Department of Health, Hong Kong Special Administrative Region, China
| | - Lithia Lai-Ha Yuen
- Infection Control Team, Queen Mary Hospital, Hong Kong West Cluster, Hong Kong Special Administrative Region, China
| | - Xin Li
- Department of Microbiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong Special Administrative Region, China
| | - David Christopher Lung
- Department of Pathology, Hong Kong Children's Hospital / Queen Elizabeth Hospital, Hong Kong Special Administrative Region, China
| | - Allen Wing-Ho Chu
- Department of Microbiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Jonathan Daniel Ip
- Department of Microbiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Wan-Mui Chan
- Department of Microbiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Hoi-Wah Tsoi
- Department of Microbiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Kelvin Kai-Wang To
- Department of Microbiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Kwok-Yung Yuen
- Department of Microbiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Vincent Chi-Chung Cheng
- Infection Control Team, Queen Mary Hospital, Hong Kong West Cluster, Hong Kong Special Administrative Region, China.,Department of Microbiology, Queen Mary Hospital, Hong Kong Special Administrative Region, China
| |
Collapse
|
50
|
Coyle JP, Derk RC, Lindsley WG, Blachere FM, Boots T, Lemons AR, Martin SB, Mead KR, Fotta SA, Reynolds JS, McKinney WG, Sinsel EW, Beezhold DH, Noti JD. Efficacy of Ventilation, HEPA Air Cleaners, Universal Masking, and Physical Distancing for Reducing Exposure to Simulated Exhaled Aerosols in a Meeting Room. Viruses 2021; 13:2536. [PMID: 34960804 PMCID: PMC8707272 DOI: 10.3390/v13122536] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 12/07/2021] [Accepted: 12/14/2021] [Indexed: 12/12/2022] Open
Abstract
There is strong evidence associating the indoor environment with transmission of SARS-CoV-2, the virus that causes COVID-19. SARS-CoV-2 can spread by exposure to droplets and very fine aerosol particles from respiratory fluids that are released by infected persons. Layered mitigation strategies, including but not limited to maintaining physical distancing, adequate ventilation, universal masking, avoiding overcrowding, and vaccination, have shown to be effective in reducing the spread of SARS-CoV-2 within the indoor environment. Here, we examine the effect of mitigation strategies on reducing the risk of exposure to simulated respiratory aerosol particles within a classroom-style meeting room. To quantify exposure of uninfected individuals (Recipients), surrogate respiratory aerosol particles were generated by a breathing simulator with a headform (Source) that mimicked breath exhalations. Recipients, represented by three breathing simulators with manikin headforms, were placed in a meeting room and affixed with optical particle counters to measure 0.3-3 µm aerosol particles. Universal masking of all breathing simulators with a 3-ply cotton mask reduced aerosol exposure by 50% or more compared to scenarios with simulators unmasked. While evaluating the effect of Source placement, Recipients had the highest exposure at 0.9 m in a face-to-face orientation. Ventilation reduced exposure by approximately 5% per unit increase in air change per hour (ACH), irrespective of whether increases in ACH were by the HVAC system or portable HEPA air cleaners. The results demonstrate that mitigation strategies, such as universal masking and increasing ventilation, reduce personal exposure to respiratory aerosols within a meeting room. While universal masking remains a key component of a layered mitigation strategy of exposure reduction, increasing ventilation via system HVAC or portable HEPA air cleaners further reduces exposure.
Collapse
Affiliation(s)
- Jayme P. Coyle
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV 26505, USA; (J.P.C.); (R.C.D.); (F.M.B.); (T.B.); (A.R.L.); (J.S.R.); (W.G.M.); (E.W.S.); (D.H.B.); (J.D.N.)
| | - Raymond C. Derk
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV 26505, USA; (J.P.C.); (R.C.D.); (F.M.B.); (T.B.); (A.R.L.); (J.S.R.); (W.G.M.); (E.W.S.); (D.H.B.); (J.D.N.)
| | - William G. Lindsley
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV 26505, USA; (J.P.C.); (R.C.D.); (F.M.B.); (T.B.); (A.R.L.); (J.S.R.); (W.G.M.); (E.W.S.); (D.H.B.); (J.D.N.)
| | - Francoise M. Blachere
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV 26505, USA; (J.P.C.); (R.C.D.); (F.M.B.); (T.B.); (A.R.L.); (J.S.R.); (W.G.M.); (E.W.S.); (D.H.B.); (J.D.N.)
| | - Theresa Boots
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV 26505, USA; (J.P.C.); (R.C.D.); (F.M.B.); (T.B.); (A.R.L.); (J.S.R.); (W.G.M.); (E.W.S.); (D.H.B.); (J.D.N.)
| | - Angela R. Lemons
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV 26505, USA; (J.P.C.); (R.C.D.); (F.M.B.); (T.B.); (A.R.L.); (J.S.R.); (W.G.M.); (E.W.S.); (D.H.B.); (J.D.N.)
| | - Stephen B. Martin
- Respiratory Health Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV 26505, USA;
| | - Kenneth R. Mead
- Division of Field Studies and Engineering, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Cincinnati, OH 45226, USA;
| | - Steven A. Fotta
- Facilities Management Office, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV 26505, USA;
| | - Jeffrey S. Reynolds
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV 26505, USA; (J.P.C.); (R.C.D.); (F.M.B.); (T.B.); (A.R.L.); (J.S.R.); (W.G.M.); (E.W.S.); (D.H.B.); (J.D.N.)
| | - Walter G. McKinney
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV 26505, USA; (J.P.C.); (R.C.D.); (F.M.B.); (T.B.); (A.R.L.); (J.S.R.); (W.G.M.); (E.W.S.); (D.H.B.); (J.D.N.)
| | - Erik W. Sinsel
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV 26505, USA; (J.P.C.); (R.C.D.); (F.M.B.); (T.B.); (A.R.L.); (J.S.R.); (W.G.M.); (E.W.S.); (D.H.B.); (J.D.N.)
| | - Donald H. Beezhold
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV 26505, USA; (J.P.C.); (R.C.D.); (F.M.B.); (T.B.); (A.R.L.); (J.S.R.); (W.G.M.); (E.W.S.); (D.H.B.); (J.D.N.)
| | - John D. Noti
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV 26505, USA; (J.P.C.); (R.C.D.); (F.M.B.); (T.B.); (A.R.L.); (J.S.R.); (W.G.M.); (E.W.S.); (D.H.B.); (J.D.N.)
| |
Collapse
|