1
|
Kataoka H, Ishizaki A, Saito K, Ehara K. Developments and Applications of Molecularly Imprinted Polymer-Based In-Tube Solid Phase Microextraction Technique for Efficient Sample Preparation. Molecules 2024; 29:4472. [PMID: 39339467 PMCID: PMC11433927 DOI: 10.3390/molecules29184472] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2024] [Revised: 09/15/2024] [Accepted: 09/18/2024] [Indexed: 09/30/2024] Open
Abstract
Despite advancements in the sensitivity and performance of analytical instruments, sample preparation remains a bottleneck in the analytical process. Currently, solid-phase extraction is more widely used than traditional organic solvent extraction due to its ease of use and lower solvent requirements. Moreover, various microextraction techniques such as micro solid-phase extraction, dispersive micro solid-phase extraction, solid-phase microextraction, stir bar sorptive extraction, liquid-phase microextraction, and magnetic bead extraction have been developed to minimize sample size, reduce solvent usage, and enable automation. Among these, in-tube solid-phase microextraction (IT-SPME) using capillaries as extraction devices has gained attention as an advanced "green extraction technique" that combines miniaturization, on-line automation, and reduced solvent consumption. Capillary tubes in IT-SPME are categorized into configurations: inner-wall-coated, particle-packed, fiber-packed, and rod monolith, operating either in a draw/eject system or a flow-through system. Additionally, the developments of novel adsorbents such as monoliths, ionic liquids, restricted-access materials, molecularly imprinted polymers (MIPs), graphene, carbon nanotubes, inorganic nanoparticles, and organometallic frameworks have improved extraction efficiency and selectivity. MIPs, in particular, are stable, custom-made polymers with molecular recognition capabilities formed during synthesis, making them exceptional "smart adsorbents" for selective sample preparation. The MIP fabrication process involves three main stages: pre-arrangement for recognition capability, polymerization, and template removal. After forming the template-monomer complex, polymerization creates a polymer network where the template molecules are anchored, and the final step involves removing the template to produce an MIP with cavities complementary to the template molecules. This review is the first paper to focus on advanced MIP-based IT-SPME, which integrates the selectivity of MIPs into efficient IT-SPME, and summarizes its recent developments and applications.
Collapse
Affiliation(s)
- Hiroyuki Kataoka
- School of Pharmacy, Shujitsu University, Nishigawara, Okayama 703-8516, Japan
| | - Atsushi Ishizaki
- School of Pharmacy, Shujitsu University, Nishigawara, Okayama 703-8516, Japan
| | - Keita Saito
- School of Pharmacy, Shujitsu University, Nishigawara, Okayama 703-8516, Japan
| | - Kentaro Ehara
- School of Pharmacy, Shujitsu University, Nishigawara, Okayama 703-8516, Japan
| |
Collapse
|
2
|
Xiong J, Zhao S, Zhang X, Tian Y, Ma L, Zhou Y, Huang C. Investigation of biodistribution by liquid-phase microextraction: Using a fatal diphenidol poisoning case. J Chromatogr A 2024; 1732:465221. [PMID: 39106662 DOI: 10.1016/j.chroma.2024.465221] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2024] [Revised: 07/21/2024] [Accepted: 07/31/2024] [Indexed: 08/09/2024]
Abstract
Liquid-phase microextraction (LPME) possesses a high potential to isolate organic substances from different sample matrices. In this work, LPME was applied for the first time to investigate the biodistribution of diphenidol in different biofluids, organs, and brain regions using a fatal poisoning case. Since the LPME of diphenidol hasn't been reported, the effect of supported liquid membrane (SLM), acceptor and donor phases, and extraction time on LPME performance was investigated first. The solvents of 2-nonanone and 2-nitrophenyl octyl ether (NPOE) were found to be stable and efficient SLMs for LPME of diphenidol from biofluids and tissue samples, respectively. At steady state, the LPME recoveries for different sample matrices were in the range of 87 %-91 %. Due to the clean-up capability of LPME and the relatively high concentration of diphenidol in the fatal poisoning case, the proposed LPME systems were validated with related sample matrices using HPLC-UV for the determination. The methods displayed good linearity (R² ≥ 0.9943), and the limits of detection were 0.30 mg L-1, 0.28 mg L-1, and 2.7 μg g-1 for blood, urine, and liver samples, respectively. Meanwhile, the precision (≤13%), accuracy (90-110%), and matrices effect (±15%) were satisfactory at low, medium, and high concentrations. In addition, the stability, carryover, and dilution integrity met the requirements of ASB Standard 036. Finally, the proposed method was successfully applied to evaluate the biodistribution of diphenidol in five different biofluids, five organs, and six brain regions from a fatal poisoning case. Generally, the distribution of diphenidol in biofluids was lower than that in the organs and brain regions, and the highest concentration of diphenidol was observed in the liver, which is very important for the selection of inspection samples in forensic toxicological analysis. Therefore, LPME was proved to be a powerful tool for the investigation of biodistribution and postmortem redistribution in the fields of forensics.
Collapse
Affiliation(s)
- Jianhua Xiong
- Department of Forensic Medicine, Huazhong University of Science and Technology, Wuhan 430030, China
| | - Shuquan Zhao
- Faculty of Forensic Medicine, Guangdong Province Translational Forensic Medicine Engineering Technology Research Center, Zhongshan School of Medicine, Sun Yat-Sen University, Guangzhou 510080, China
| | - Xinwei Zhang
- Department of Forensic Medicine, Huazhong University of Science and Technology, Wuhan 430030, China
| | - Yu Tian
- Department of Forensic Medicine, Huazhong University of Science and Technology, Wuhan 430030, China
| | - Longda Ma
- Department of Forensic Medicine, Huazhong University of Science and Technology, Wuhan 430030, China
| | - Yiwu Zhou
- Department of Forensic Medicine, Huazhong University of Science and Technology, Wuhan 430030, China.
| | - Chuixiu Huang
- Department of Forensic Medicine, Huazhong University of Science and Technology, Wuhan 430030, China.
| |
Collapse
|
3
|
Alqarni AM. Analytical Methods for the Determination of Pharmaceuticals and Personal Care Products in Solid and Liquid Environmental Matrices: A Review. Molecules 2024; 29:3900. [PMID: 39202981 PMCID: PMC11357415 DOI: 10.3390/molecules29163900] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2024] [Revised: 08/07/2024] [Accepted: 08/16/2024] [Indexed: 09/03/2024] Open
Abstract
Among the various compounds regarded as emerging contaminants (ECs), pharmaceuticals and personal care products (PPCPs) are of particular concern. Their continuous release into the environment has a negative global impact on human life. This review summarizes the sources, occurrence, persistence, consequences of exposure, and toxicity of PPCPs, and evaluates the various analytical methods used in the identification and quantification of PPCPs in a variety of solid and liquid environmental matrices. The current techniques of choice for the analysis of PPCPs are state-of-the-art liquid chromatography coupled to mass spectrometry (LC-MS) or tandem mass spectrometry (LC-MS2). However, the complexity of the environmental matrices and the trace levels of micropollutants necessitate the use of advanced sample treatments before these instrumental analyses. Solid-phase extraction (SPE) with different sorbents is now the predominant method used for the extraction of PPCPs from environmental samples. This review also addresses the ongoing analytical method challenges, including sample clean-up and matrix effects, focusing on the occurrence, sample preparation, and analytical methods presently available for the determination of environmental residues of PPCPs. Continuous development of innovative analytical methods is essential for overcoming existing limitations and ensuring the consistency and diversity of analytical methods used in investigations of environmental multi-class compounds.
Collapse
Affiliation(s)
- Abdulmalik M Alqarni
- Department of Pharmaceutical Chemistry, College of Clinical Pharmacy, Imam Abdulrahman Bin Faisal University, King Faisal Road, P.O. Box 1982, Dammam 31441, Saudi Arabia
| |
Collapse
|
4
|
Nourani N, Taghvimi A, Bavili-Tabrizi A, Javadzadeh Y, Dastmalchi S. Microextraction Techniques for Sample Preparation of Amphetamines in Urine: A Comprehensive Review. Crit Rev Anal Chem 2024; 54:1304-1319. [PMID: 36093632 DOI: 10.1080/10408347.2022.2113028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
Abstract
Psychological disorders and dramatic social problems are serious concerns regarding the abuse of amphetamine and its stimulant derivatives worldwide. Consumers of such drugs experience great euphoria along with serious health problems. Determination and quantification of amphetamine-type stimulants are indispensable skills for clinical and forensic laboratories. Analysis of low drug doses in bio-matrices necessitates applications of simple and also effective preparation steps. The preparation procedures not only eliminate adverse matrix effects, but also provide reasonable clean-up and pre-concentration benefits. The current review presents different methods used for sample preparation of amphetamines from urine as the most frequently used biological matrix. The advantages and limitations of various sample preparation methods were discussed focusing on the miniaturized methods.
Collapse
Affiliation(s)
- Nasim Nourani
- Student Research Committee, Tabriz University of Medical Sciences, Tabriz, Iran
- Biotechnology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
- Department of Medicinal Chemistry, Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Arezou Taghvimi
- Biotechnology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Ahad Bavili-Tabrizi
- Department of Medicinal Chemistry, Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran
- Pharmaceutical Analysis Research Center and Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Yousef Javadzadeh
- Biotechnology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
- Department of Pharmaceutics, Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Siavoush Dastmalchi
- Biotechnology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
- Department of Medicinal Chemistry, Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran
- Faculty of Pharmacy, Near East University, North Cyprus, Turkey
| |
Collapse
|
5
|
Martínez-Pérez-Cejuela H, Gionfriddo E. Evolution of Green Sample Preparation: Fostering a Sustainable Tomorrow in Analytical Sciences. Anal Chem 2024; 96:7840-7863. [PMID: 38687329 DOI: 10.1021/acs.analchem.4c01328] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/02/2024]
Affiliation(s)
- H Martínez-Pérez-Cejuela
- Department of Chemistry, University at Buffalo, The State University of New York, Buffalo, New York 14260-3000, United States
| | - E Gionfriddo
- Department of Chemistry, University at Buffalo, The State University of New York, Buffalo, New York 14260-3000, United States
| |
Collapse
|
6
|
Bintanel-Cenis J, Fernández MA, Gómara B, Ramos L. Critical overview on the use of hydrophobic (deep) eutectic solvents for the extraction of organic pollutants in complex matrices. Talanta 2024; 270:125599. [PMID: 38199124 DOI: 10.1016/j.talanta.2023.125599] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Revised: 12/21/2023] [Accepted: 12/23/2023] [Indexed: 01/12/2024]
Abstract
During the last decades, many efforts have been devoted to the adaptation of sample preparation techniques and methods to the principles of Green Analytical Chemistry. Among them, this article review focusses on those aimed to green the solvents involved in sample treatment. Research in this field started in the late 1990s with the synthesis of room temperature ionic liquids, which were later replaced by the deep eutectic solvents (DESs). During the last years, a subclass of DESs, the so-called hydrophobic deep eutectic solvents (HDESs) have attracted attention. HDESs have contributed to circumventing some of the limitations of early-synthesised hydrophilic DESs regarding the cost of raw materials, the simplicity of synthesis, and the biocompatibility and, apparently, the biodegradability of the mixtures. In addition, these mixtures allowed the treatment of aqueous samples and the extraction of non-polar analytes. This article discusses fundamental aspects regarding the nomenclature used concerning HDESs, summarises the main physicochemical properties of these mixtures, and through discussion of key application studies, describes current progress in the use of these green solvents for the extraction of trace organic contaminants from a variety of matrices. Remaining gaps and possible lines of future development in this emerging, active and attractive research area are also identified and critically discussed.
Collapse
Affiliation(s)
- J Bintanel-Cenis
- Department of Instrumental Analysis and Environmental Chemistry, IQOG-CSIC, Juan de la Cierva 3, 28006, Madrid, Spain
| | - M A Fernández
- Department of Instrumental Analysis and Environmental Chemistry, IQOG-CSIC, Juan de la Cierva 3, 28006, Madrid, Spain
| | - B Gómara
- Department of Instrumental Analysis and Environmental Chemistry, IQOG-CSIC, Juan de la Cierva 3, 28006, Madrid, Spain
| | - L Ramos
- Department of Instrumental Analysis and Environmental Chemistry, IQOG-CSIC, Juan de la Cierva 3, 28006, Madrid, Spain.
| |
Collapse
|
7
|
Pour PH, Suzaei FM, Daryanavard SM. Greenness assessment of microextraction techniques in therapeutic drug monitoring. Bioanalysis 2024; 16:249-278. [PMID: 38466891 PMCID: PMC11216521 DOI: 10.4155/bio-2023-0266] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Accepted: 02/08/2024] [Indexed: 03/13/2024] Open
Abstract
Aim: In this study, we evaluated the greenness and whiteness scores for microextraction techniques used in therapeutic drug monitoring. Additionally, the cons and pros of each evaluated method and their impacts on the provided scores are also discussed. Materials & methods: The Analytical Greenness Sample Preparation metric tool and white analytical chemistry principles are used for related published works (2007-2023). Results & conclusion: This study provided valuable insights for developing methods based on microextraction techniques with a balance in greenness and whiteness areas. Some methods based on a specific technique recorded higher scores, making them suitable candidates as green analytical approaches, and some others achieved high scores both in green and white areas with a satisfactory balance between principles.
Collapse
Affiliation(s)
- Parastoo Hosseini Pour
- Department of Chemistry, Faculty of Science, University of Hormozgan, Bandar-Abbas, 79177, Iran
| | - Foad Mashayekhi Suzaei
- Toxicology Laboratories, Monitoring the Human Hygiene Condition and Standard of Qeshm (MHCS Company), Qeshm Island, 79511, Iran
| | | |
Collapse
|
8
|
Isabella Cestaro B, Cavalcanti Machado K, Batista M, José Gonçalves da Silva B. Hollow-fiber liquid phase microextraction for determination of fluoxetine in human serum by nano-liquid chromatography coupled to high resolution mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci 2024; 1234:124018. [PMID: 38286102 DOI: 10.1016/j.jchromb.2024.124018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Revised: 01/03/2024] [Accepted: 01/15/2024] [Indexed: 01/31/2024]
Abstract
Therapeutic drug monitoring (TDM) is a personalized care tool based on the determination of a target drug concentration in human serum. An antidepressant drug of interest for such investigations is fluoxetine (FXT), due to a severe impact of genetic polymorphisms on its metabolism. A bioanalytical method employed for TDM purposes must exhibit satisfactory selectivity and detectability, which becomes more difficult due to highly complex biological matrices. In this study, a highly selective bioanalytical method for the determination of FXT in human serum is proposed, which provides excellent clean-up efficiency based on a low cost hollow fiber liquid-phase microextraction (HF-LPME) sample preparation step and nano-liquid chromatography coupled to high-resolution mass spectrometry (nano-LC-HRMS). HF-LPME was performed using a two-phase "U" configuration, with 6 cm fiber, 20 µL of 1-octanol acting as supported liquid membrane, and ammonium hydroxide (pH 10) as the donor phase with NaCl (10 % m/v) and methanol (5 % v/v) as additives, requiring only 250 µL of the sample. The procedure was conducted for 30 min under a 750 rpm stirring rate. Gradient elution was carried out employing an acetonitrile-water as mobile phase, the composition of 30:70 to 100:00 (v/v) for 15 min, using formic acid 0.1 % (v/v) as an additive. MS1 was acquired in an Orbitrap mass analyzer, while MS2 was acquired in a linear trap quadrupole. Satisfactory linearity (Pearson's r = 0.99709) was obtained for a concentration range of 0.02 to 2.5 µg mL-1, which is compatible with the therapeutic and toxic range for FXT. The developed method presents adequate precision (1.61 to 7.45 %) and accuracy (95 to 114 %) and allows the dilution of high concentration samples in a 1:4 ratio (v/v), enabling its application for forensic serum samples. To our knowledge, this is the first study reporting a method based on HF-LPME and nano-LC-HRMS with any analytical purpose, especially with a TDM focus.
Collapse
Affiliation(s)
| | | | - Michel Batista
- Mass Spectrometry Facility RPT02H, Carlos Chagas Institute, Fiocruz, Curitiba 81350-010, Brazil
| | | |
Collapse
|
9
|
Grazina L, Mafra I, Monaci L, Amaral JS. Mass spectrometry-based approaches to assess the botanical authenticity of dietary supplements. Compr Rev Food Sci Food Saf 2023; 22:3870-3909. [PMID: 37548598 DOI: 10.1111/1541-4337.13222] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Revised: 07/05/2023] [Accepted: 07/18/2023] [Indexed: 08/08/2023]
Abstract
Dietary supplements are legally considered foods despite frequently including medicinal plants as ingredients. Currently, the consumption of herbal dietary supplements, also known as plant food supplements (PFS), is increasing worldwide and some raw botanicals, highly demanded due to their popularity, extensive use, and/or well-established pharmacological effects, have been attaining high prices in the international markets. Therefore, botanical adulteration for profit increase can occur along the whole PFS industry chain, from raw botanicals to plant extracts, until final PFS. Besides the substitution of high-value species, unintentional mislabeling can happen in morphologically similar species. Both cases represent a health risk for consumers, prompting the development of numerous works to access botanical adulterations in PFS. Among different approaches proposed for this purpose, mass spectrometry (MS)-based techniques have often been reported as the most promising, particularly when hyphenated with chromatographic techniques. Thus, this review aims at describing an overview of the developments in this field, focusing on the applications of MS-based techniques to targeted and untargeted analysis to detect botanical adulterations in plant materials, extracts, and PFS.
Collapse
Affiliation(s)
- Liliana Grazina
- REQUIMTE-LAQV, Faculdade de Farmácia, Universidade do Porto, Porto, Portugal
| | - Isabel Mafra
- REQUIMTE-LAQV, Faculdade de Farmácia, Universidade do Porto, Porto, Portugal
| | - Linda Monaci
- ISPA-CNR, Institute of Sciences of Food Production of National Research Council of Italy, Bari, Italy
| | - Joana S Amaral
- Centro de Investigação de Montanha (CIMO), Instituto Politécnico de Bragança, Bragança, Portugal
- Laboratório Associado para a Sustentabilidade e Tecnologia em Regiões de Montanha (SusTEC), Instituto Politécnico de Bragança, Bragança, Portugal
| |
Collapse
|
10
|
Ni B, Ye J, Xuan Z, Li L, Wen X, Li Z, Liu H, Wang S. Automatic Pretreatment of Dispersive Liquid Liquid Microextraction Based on Immunomagnetic Beads Coupled with UPLC-FLD for the Determination of Zearalenone in Corn Oils. Toxins (Basel) 2023; 15:toxins15050337. [PMID: 37235371 DOI: 10.3390/toxins15050337] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Revised: 05/09/2023] [Accepted: 05/11/2023] [Indexed: 05/28/2023] Open
Abstract
Sample pretreatment is a vital step in the detection of mycotoxins, and traditional pretreatment methods are time-consuming, labor-intensive and generate much organic waste liquid. In this work, an automatic, high-throughput and environmentally friendly pretreatment method is proposed. Immunomagnetic beads technology and dispersive liquid-liquid microextraction technology are combined, and the zearalenone in corn oils is directly purified and concentrated under the solubilization effects of surfactant. The proposed pretreatment method allows for the batch pretreatment of samples without pre-extraction using organic reagents, and almost no organic waste liquid is produced. Coupled with UPLC-FLD, an effective and accurate quantitative detection method for zearalenone is established. The recovery of spiked zearalenone in corn oils at different concentrations ranges from 85.7 to 89.0%, and the relative standard deviation is below 2.9%. The proposed pretreatment method overcomes the shortcomings of traditional pretreatment methods and has broad application prospects.
Collapse
Affiliation(s)
- Baoxia Ni
- Academy of National Food and Strategic Reserves Administration, No. 11 Baiwanzhuang Street, Beijing 100037, China
| | - Jin Ye
- Academy of National Food and Strategic Reserves Administration, No. 11 Baiwanzhuang Street, Beijing 100037, China
| | - Zhihong Xuan
- Academy of National Food and Strategic Reserves Administration, No. 11 Baiwanzhuang Street, Beijing 100037, China
| | - Li Li
- Academy of National Food and Strategic Reserves Administration, No. 11 Baiwanzhuang Street, Beijing 100037, China
| | - Xiangrui Wen
- Academy of National Food and Strategic Reserves Administration, No. 11 Baiwanzhuang Street, Beijing 100037, China
- College of Food Science and Engineering, Central South University of Forestry and Technology, Changsha 410004, China
| | - Zongwang Li
- Academy of National Food and Strategic Reserves Administration, No. 11 Baiwanzhuang Street, Beijing 100037, China
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Hongmei Liu
- Academy of National Food and Strategic Reserves Administration, No. 11 Baiwanzhuang Street, Beijing 100037, China
| | - Songxue Wang
- Academy of National Food and Strategic Reserves Administration, No. 11 Baiwanzhuang Street, Beijing 100037, China
| |
Collapse
|
11
|
Xu XL, Wang B, Liu YW, Li WX, Wu JY, Yuan H, Xu X, Chen D. In-pipette-tip natural-feather-supported liquid microextraction for conveniently extracting hydrophobic compounds in aqueous samples: A proof-of-concept study. Microchem J 2023. [DOI: 10.1016/j.microc.2022.108274] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
12
|
Switchable hydrophilicity solvent-based microextraction coupled with fluorescent detection of dichlorvos. J Food Compost Anal 2023. [DOI: 10.1016/j.jfca.2023.105165] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
|
13
|
Chaves RS, Rodrigues JE, Santos MM, Benoliel MJ, Cardoso VV. Development of multi-residue gas chromatography coupled with mass spectrometry methodologies for the measurement of 15 chemically different disinfection by-products (DBPs) of emerging concern in drinking water from two different Portuguese water treatment plants. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:4967-4976. [PMID: 36441195 DOI: 10.1039/d2ay01401g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
In water treatment plants (WTPs), chemical agents, such as chlorine and ozone, might react with organic matter and anthropogenic contaminants, forming a high diversity of disinfection by-products (DBPs). Due to the potential toxicological effects, the identification of unregulated DBPs (UR-DBPs) is critical to help water managers in the selection of effective water treatment processes, contributing to improving water safety plans. Given the limited validated analytical methods to detect UR-DBPs, here we developed new multi-residue gas chromatography coupled with mass spectrometry methodologies for the detection and quantification of 15 UR-DBPs, including aldehydes, haloketones (HKs), nitrosamines and alcohols, in drinking water matrices. Solid-phase extraction (SPE), for the nitrosamine group, and solid-phase micro extraction (SPME), for the remaining DBPs, were used as sample preparation methods. The developed methodologies allowed the quantification of target UR-DBPs at trace concentration levels (ng L-1), with method quantification limits (MQLs) ranging from 14.4 ng L-1 to 26.0 ng L-1 (SPE-GC-MS) and 2.3 ng L-1 and 1596 ng L-1 (SPME-GC-MS). The methods were applied to different drinking water matrices, considering distinct delivery points of EPAL - Empresa Portuguesa das Águas Livres WTPs. Overall, the aldehyde group, represented by decanal, nonanal and 2-ethylheaxanal, showed the highest occurrence, followed by HKs and nitrosamines. The results of this study suggested that the formation of these UR-DBPs should be further monitored in WTPs.
Collapse
Affiliation(s)
- Raquel S Chaves
- Institute of Environmental Health, Faculty of Medicine, University of Lisbon, Portugal
- Empresa Portuguesa das Águas Livres, S. A., Direção Laboratórios e de Controlo da Qualidade da Água, Lisbon, Portugal
- CIIMAR, LA-Interdisciplinary Centre of Marine and Environmental Research, University of Porto, Portugal.
| | - Joao E Rodrigues
- Empresa Portuguesa das Águas Livres, S. A., Direção Laboratórios e de Controlo da Qualidade da Água, Lisbon, Portugal
| | - Miguel M Santos
- CIIMAR, LA-Interdisciplinary Centre of Marine and Environmental Research, University of Porto, Portugal.
- FCUP-Department of Biology, Faculty of Sciences, University of Porto, Portugal
| | - Maria J Benoliel
- Empresa Portuguesa das Águas Livres, S. A., Direção Laboratórios e de Controlo da Qualidade da Água, Lisbon, Portugal
| | - Vitor V Cardoso
- Empresa Portuguesa das Águas Livres, S. A., Direção Laboratórios e de Controlo da Qualidade da Água, Lisbon, Portugal
| |
Collapse
|
14
|
Flower-like mesoporous Fe3O4@SiO2@F/NiO composites for magnetic solid-phase extraction of imidazole fungicides in tap water, milk and green tea. Microchem J 2022. [DOI: 10.1016/j.microc.2022.108292] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
15
|
Crucello J, de Oliveira AM, Sampaio NMFM, Hantao LW. Miniaturized systems for gas chromatography: Developments in sample preparation and instrumentation. J Chromatogr A 2022; 1685:463603. [DOI: 10.1016/j.chroma.2022.463603] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 10/07/2022] [Accepted: 10/23/2022] [Indexed: 11/07/2022]
|
16
|
Hoseinpour Kouhestany R, Tamaddon A, Ahmad Panahi H, Afshar Ebrahimi A, Amiri R. Hyper-branched nanodendrimer as a novel solid-phase extraction sorbent followed by three phase hollow fiber microextraction for trace separation of exemestane. J Mol Liq 2022. [DOI: 10.1016/j.molliq.2022.121142] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
17
|
Wei R, Hu L, Wang L, Yan P, Lin T, Wang N, Sun H, Zheng B, Guo C. High-voltage pulse-assisted extraction of flavonoids from kapok using deep eutectic solvent aqueous solutions. RSC Adv 2022; 12:25025-25034. [PMID: 36199877 PMCID: PMC9437896 DOI: 10.1039/d2ra03969a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Accepted: 08/24/2022] [Indexed: 11/21/2022] Open
Abstract
In this study, deep eutectic solvents coupled with a pulsed electric field (PEF-DES) were first applied to the extraction of traditional Chinese medicine plants. This study uses the PEF-DES extraction technique to extract TG-KF (Kapok flavonoid solution extracted with DES-TG). PEF-DES is a simple, effective and environmentally-friendly technology and can be used in industrial-scale production. For the optimal extraction conditions of TG-KF, DES-TG was used as a solvent, the DES-TG concentration was 50%, the solid-liquid ratio was 1 : 30, the electric field intensity was 0.55 kV cm-1, the number of pulses was 100, and the yield of flavonoids was 14.36 ± 0.35%. TG-KF has very good stability and there is no precipitation or discoloration within 6 months. The results of chicken embryo experiments and human patch tests show that 10% TG-KF aqueous solution has no irritation. DPPH experiments show that TG-KF has excellent efficacy as an antioxidant. Overall, TG-KF is expected to become a potential antioxidant raw material.
Collapse
Affiliation(s)
- Ruijing Wei
- Research and Development Center, Guangdong Marubi Biotechnology Co., Ltd. 510530 Guangdong China
- School of Food Science and Engineering, South China University of Technology 381 Wushan Road Guangzhou 510640 Guangdong China
| | - Lu Hu
- Research and Development Center, Guangdong Marubi Biotechnology Co., Ltd. 510530 Guangdong China
| | - Lihua Wang
- Research and Development Center, Guangdong Marubi Biotechnology Co., Ltd. 510530 Guangdong China
| | - Peng Yan
- Research and Development Center, Guangdong Marubi Biotechnology Co., Ltd. 510530 Guangdong China
| | - Tao Lin
- Research and Development Center, Guangdong Marubi Biotechnology Co., Ltd. 510530 Guangdong China
| | - Ning Wang
- Research and Development Center, Guangdong Marubi Biotechnology Co., Ltd. 510530 Guangdong China
| | - Huaiqing Sun
- Research and Development Center, Guangdong Marubi Biotechnology Co., Ltd. 510530 Guangdong China
| | - Bisheng Zheng
- School of Food Science and Engineering, South China University of Technology 381 Wushan Road Guangzhou 510640 Guangdong China
| | - Chaowan Guo
- Research and Development Center, Guangdong Marubi Biotechnology Co., Ltd. 510530 Guangdong China
| |
Collapse
|
18
|
Green bioanalysis: an innovative and eco-friendly approach for analyzing drugs in biological matrices. Bioanalysis 2022; 14:881-909. [PMID: 35946313 DOI: 10.4155/bio-2022-0095] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Green bioanalytical techniques aim to reduce or eliminate the hazardous waste produced by bioanalytical technologies. A well-organized and practical approach towards bioanalytical method development has an enormous contribution to the green analysis. The selection of the appropriate sample extraction process, organic mobile phase components and separation technique makes the bioanalytical method green. UHPLC-MS is the best option, whereas supercritical fluid chromatography is one of the most effective green bioanalytical procedures. Nevertheless, there remains excellent scope for further research on green bioanalytical methods. This review details the various sample preparation techniques that follow green analytical chemistry principles. Furthermore, it presents green solvents as a replacement for conventional organic solvents and highlights the strategies to convert modern analytical techniques to green methods.
Collapse
|
19
|
Jalili V, Ghanbari Kakavandi M, Ghiasvand A, Barkhordari A. Microextraction techniques for sampling and determination of polychlorinated biphenyls: A comprehensive review. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107442] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
20
|
Agrawal A, Yıldız ÜY, Hussain CG, Kailasa SK, Keçili R, Hussain CM. Greenness of lab-on-a-chip devices for analytical processes: Advances & future prospects. J Pharm Biomed Anal 2022; 219:114914. [PMID: 35843186 DOI: 10.1016/j.jpba.2022.114914] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2022] [Revised: 06/22/2022] [Accepted: 06/25/2022] [Indexed: 11/25/2022]
Abstract
Lab-on-a-chip devices have now-a-days become an important aspect of analytical/bioanalytical chemistry having wide range of applications including clinical diagnosis, drug screening, cell biology, environmental monitoring, food safety analysis etc. Conventional lab-on-a-chip devices generally employ chemicals that are not environmentally friendly and were commonly fabricated on hard plastic platform which are non-degradable and hence ignore the importance of green analytical chemistry. In today's scenario, it is highly imperative to protect our environment by using less toxic and environmentally friendly chemicals/solvents and biocompatible platforms. Accordingly, the present article comprehensively reviews on the various green aspects of lab-on-a-chip devices for analytical processes which aim at fabricating environmentally friendly and cost-effective downsized devices so that the risk factor at the user's end upon longer exposure as well as to the environment can be reduced. The decisive factors for the accomplishment of green aspects of lab-on-a-chip devices including sample preparation using lab-on-a-chip systems to minimize the amount of sample/solvents to few microliters only, substitution of harmful solvents with green alternatives, minimal waste generation or proper treatment of waste and biodegradable and biocompatible platforms for fabricating lab-on-a-chip devices have been discussed in details. Additionally, the challenges that may hinder their commercialization are also critically discussed.
Collapse
Affiliation(s)
- Arpana Agrawal
- Department of Physics, Shri Neelkantheshwar Government Post-Graduate College, Khandwa 450001, India
| | - Ümit Yılmaz Yıldız
- Department of Medical Services and Techniques, Yunus Emre Vocational School of Health Services, Anadolu University, 26470 Eskişehir, Turkey
| | | | - Suresh Kumar Kailasa
- Department of Chemistry, Sardar Vallabhbhai National Institute of Technology, Surat, 395 007, Gujarat, India
| | - Rüstem Keçili
- Department of Medical Services and Techniques, Yunus Emre Vocational School of Health Services, Anadolu University, 26470 Eskişehir, Turkey
| | - Chaudhery Mustansar Hussain
- Department of Chemistry and Environmental Science, New Jersey Institute of Technology, Newark, NJ 07102, USA.
| |
Collapse
|
21
|
Determination of Ochratoxin A and Its Metabolite Ochratoxin Alpha in Different Food Matrices After Enzymatic Biotransformation. FOOD ANAL METHOD 2022. [DOI: 10.1007/s12161-022-02349-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
22
|
Olasupo A, Suah FBM. Trends in hollow fibre liquid phase microextraction for the preconcentration of pharmaceutically active compounds in aqueous solution: A case for polymer inclusion membrane. JOURNAL OF HAZARDOUS MATERIALS 2022; 431:128573. [PMID: 35278960 DOI: 10.1016/j.jhazmat.2022.128573] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/18/2021] [Revised: 02/06/2022] [Accepted: 02/23/2022] [Indexed: 06/14/2023]
Abstract
Low concentrations of pharmaceutically active compounds have been reported in samples from highly complex aqueous environments. Due to their low concentrations, efficient sample pretreatment methods are needed to clean samples and concentrate the compounds of interest prior to instrumental analysis. Hollow fibre liquid-phase microextraction (HF-LPME) is an effective alternative to conventional techniques such as liquid-liquid extraction (LLE) and solid phase extraction (SPE) because it consumes less organic solvent and is less labour intensive with a short extraction time. HF-LPME involves the preconcentration and mass transfer of target analytes from an aqueous sample into an acceptor solution in the lumen of the fibre using a supported liquid membrane (SLM) impregnated in the hollow fibre pores. However, despite the high contaminant selectivity, reproducibility, and enrichment that HF-LPME offers, this technique is limited by membrane instability. Although several advances have been made to address membrane instability, they are either too costly or not feasible for industrial application. Hence, hollow fibre polymer inclusion membrane liquid-phase microextraction (HF-PIM-LPME) was introduced to ameliorate membrane instability. This new approach uses ionic liquids (ILs) as a green solvent, and has demonstrated high membrane stability, good contaminant enrichment, and similar selectivity and reproducibility to HF-SLM-LPME. Hence, this review aims to raise awareness of HF-PIM-LPME as a viable alternative for the selectivity and preconcentration of pharmaceuticals and other contaminants in aquatic environments.
Collapse
Affiliation(s)
- Ayo Olasupo
- Green Analytical Chemistry Laboratory, School of Chemical Sciences, Universiti Sains Malaysia, 11800 Minden, Pulau Pinang, Malaysia
| | - Faiz Bukhari Mohd Suah
- Green Analytical Chemistry Laboratory, School of Chemical Sciences, Universiti Sains Malaysia, 11800 Minden, Pulau Pinang, Malaysia.
| |
Collapse
|
23
|
Gu YX, Yan TC, Yue ZX, Liu FM, Cao J, Ye LH. Recent developments and applications in the microextraction and separation technology of harmful substances in a complex matrix. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107241] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
24
|
Zhong M, Lao Z, Tan J, Yu G, Liu Y, Liang Y. Synthesis of CoNi-layered double hydroxide on graphene oxide as adsorbent and construction of detection method for taste and odor compounds in smelling water. JOURNAL OF HAZARDOUS MATERIALS 2022; 428:128227. [PMID: 35030483 DOI: 10.1016/j.jhazmat.2022.128227] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/05/2021] [Revised: 01/02/2022] [Accepted: 01/04/2022] [Indexed: 06/14/2023]
Abstract
Taste and odor (T&O) compounds are important water pollutant, some of which are toxic. The relevant studies are all expand upon the well-known T&O compounds but for the unknown odors in smelling water. In this work, a method combining purge and trap with gas chromatograph-mass spectrometer (PT-GC/MS) and disperse solid-phase extraction with gas chromatograph (GC) was first proposed to detect T&O compounds in unknown odorous water accurately. Firstly, PT-GC/MS was used for a qualitative test on unknown odors in smelling water and determine the analytes. The hollow CoNi-layered double hydroxide (LDH) on graphene oxide (GO) was then used as a composite adsorbent to pretreat the water, in which the GO provided large specific surface, and the LDH worked as a confinement cavity to enhance capture and retention capacity for volatile organic compounds (VOCs). According to the properties of T&O compounds determined by PT-GC/MS in water, a corresponding GC method was established for accurately quantitative analysis. In this paper, five T&O compounds were detected simultaneously, including dimethyl sulfide, meistylene, N, N-dimethylbenzylamine, 2, 4-dimethylbenzaldehyde and 2, 4-di-tert-butylphenol. Extraction parameters were optimized, including ratio of desorption solvent, amount of adsorbent, pH value, etc. Under the optimal conditions, the detection limits for analysis were 1.14 μg/L to 3.07 mg/L. The satisfactory recoveries were 94-98%. Furthermore, two optimal determination outcomes of odor waters from different places support the practicability of the method, which is expected to be widely used in the detection of unknown odors in smelling water.
Collapse
Affiliation(s)
- Mingmin Zhong
- School of Chemistry, South China Normal University, Guangzhou 510631, PR China
| | - Zhixiong Lao
- Gaoming Water Supply Co., Ltd. of Foshan Water Industry Group, Foshan 528000, PR China
| | - Jianrong Tan
- Gaoming Water Supply Co., Ltd. of Foshan Water Industry Group, Foshan 528000, PR China
| | - Guangzhou Yu
- Gaoming Water Supply Co., Ltd. of Foshan Water Industry Group, Foshan 528000, PR China
| | - Yan Liu
- Guangdong Centre for Agricultural Products Quality and Safety, Guangzhou 510631, PR China.
| | - Yong Liang
- School of Chemistry, South China Normal University, Guangzhou 510631, PR China.
| |
Collapse
|
25
|
Yıldırım S, Cocovi-Solberg DJ, Uslu B, Solich P, Horstkotte B. Lab-In-Syringe automation of deep eutectic solvent-based direct immersion single drop microextraction coupled online to high-performance liquid chromatography for the determination of fluoroquinolones. Talanta 2022; 246:123476. [PMID: 35461115 DOI: 10.1016/j.talanta.2022.123476] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2022] [Revised: 04/08/2022] [Accepted: 04/09/2022] [Indexed: 01/23/2023]
Abstract
Lab-In-Syringe direct immersion single drop microextraction is proposed as an automated sample pretreatment methodology and coupled online to HPLC with fluorescence detection for the determination of fluoroquinolones in environmental waters. For the first time, a drop of a natural deep eutectic solvent (NADES), synthesized from hexanoic acid and thymol, has been used as an extractant in automated single-drop microextraction. The extraction procedure was carried out within the 5 mL void of an automatic syringe pump. A 9-position head valve served the aspiration of all required solutions, air, waste disposal, and hyphenation with the HPLC instrument. Sample mixing during extraction was done by a magnetic stirring bar placed inside the syringe. Only 60 μL of NADES were required omitting toxic classical solvents and improving the greenness of the proposed methodology. By direct injection, linear working ranges between 0.1 and 5 μg L-1 were achieved for all fluoroquinolones. The limit of quantification values and enrichment factors ranged from 20 ng L-1 to 30 ng L-1 and 35 to 45, respectively. Accuracies obtained from the analysis of spiked surface water and wastewater treatment plant effluent analysis at two concentration levels (0.5 and 4 μg L-1) ranged from 84.6% to 119.7%, with RSD values typically <3%.
Collapse
Affiliation(s)
- Sercan Yıldırım
- Karadeniz Technical University, Faculty of Pharmacy, Department of Analytical Chemistry, Farabi Street, 61080, Trabzon, Turkey; Charles University, Faculty of Pharmacy, Department of Analytical Chemistry, Akademika Heyrovského 1203, 50005, Hradec Králové, Czech Republic
| | - David J Cocovi-Solberg
- University of Natural Resources and Life Sciences, Vienna, Department of Chemistry, Institute of Analytical Chemistry, Muthgasse 18, 1190, Vienna, Austria
| | - Bengi Uslu
- Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry, Yenimahalle, 06560, Ankara, Turkey
| | - Petr Solich
- Charles University, Faculty of Pharmacy, Department of Analytical Chemistry, Akademika Heyrovského 1203, 50005, Hradec Králové, Czech Republic
| | - Burkhard Horstkotte
- Charles University, Faculty of Pharmacy, Department of Analytical Chemistry, Akademika Heyrovského 1203, 50005, Hradec Králové, Czech Republic.
| |
Collapse
|
26
|
Dowlatshah S, Saraji M, Ramos-Payán M. A green microfluidic method based liquid phase microextraction for the determination of parabens in human urine samples. J Chromatogr A 2022; 1673:463084. [DOI: 10.1016/j.chroma.2022.463084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2022] [Revised: 04/06/2022] [Accepted: 04/20/2022] [Indexed: 10/18/2022]
|
27
|
Hsu CJ, Ding WH. Determination of benzotriazole and benzothiazole derivatives in tea beverages by deep eutectic solvent-based ultrasound-assisted liquid-phase microextraction and ultrahigh-performance liquid chromatography-high resolution mass spectrometry. Food Chem 2022; 368:130798. [PMID: 34411854 DOI: 10.1016/j.foodchem.2021.130798] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2021] [Revised: 07/02/2021] [Accepted: 08/04/2021] [Indexed: 11/27/2022]
Abstract
Benzotriazole (BTRs) and benzothiazole (BTHs) derivatives are a group of high production volume chemicals with emerging health concern, which found in tea beverages raising potential risks for food safety and human health. The present work describes a simple method using a "green" deep eutectic solvent (DES) based-ultrasound-assisted liquid-phase microextraction (UALPME) to rapidly extract BTRs and BTHs from tea beverages, and then applying UHPLC-electrospray ionization (+)-quadrupole time-of-flight mass spectrometry for detection and quantification. To overcome the challenges related to different experimental conditions, a Factorial Multilevel Categoric Design and a Face Centered Central Composite Design were applied to screen and optimize the parameters for the DES-UALPME procedure, respectively. After optimization, the method was validated and shown to possess low limits of quantification (LOQs; 1.5-12 ng mL-1), high precision (3-13%), and satisfactory accuracy (65-107%). The developed method was then successfully applied for the analysis of some selected BTRs and BTHs in tea beverages.
Collapse
Affiliation(s)
- Che-Jui Hsu
- Department of Chemistry, National Central University, Chung-Li 320, Taiwan
| | - Wang-Hsien Ding
- Department of Chemistry, National Central University, Chung-Li 320, Taiwan.
| |
Collapse
|
28
|
Topal S, Şaylan M, Zaman BT, Bakırdere S. Determination of trace cadmium in saliva samples using spray assisted droplet formation-liquid phase microextraction prior to the measurement by slotted quartz tube-flame atomic absorption spectrophotometry. J Trace Elem Med Biol 2021; 68:126859. [PMID: 34564028 DOI: 10.1016/j.jtemb.2021.126859] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/30/2021] [Revised: 08/05/2021] [Accepted: 09/10/2021] [Indexed: 11/18/2022]
Abstract
BACKGROUND An effective, green and rapid analytical strategy namely the simultaneous spray assisted droplet formation-liquid phase microextraction (S-SADF-LPME) method was developed for the determination of trace quantity of cadmium in saliva samples by using the slotted quartz tube-flame atomic absorption spectrophotometry (SQT-FAAS). By the developed method, external dispersive solvent usage for droplet formation was reduced to obtain a more environmental-friendly method. METHODS Method consists of a simultaneous complexing and extraction step, which was based on spraying an extraction solvent containing a solid ligand into the aqueous sample solution, forming fine droplets without the use of dispersive solvent. The procedure was implemented using a customized, cost effective and portable spray apparatus to minimize the consumption of reagent, analysis time and operation steps. Thus, this methodology ensures better repeatability and accuracy while minimizing the relative errors caused by the experimental steps. Parameters including the buffer amount, extractant/ligand concentration, extraction solvent type, extraction/ligand solution volume, spraying number and vortex period were systemically optimized to lower the detection limit. RESULTS Under the optimal extraction conditions, 96.9-folds enhancement in the detection power of the traditional FAAS was achieved. The limit of detection and limit of quantification values of presented method were calculated to be 0.65 and 2.17 ng mL-1, respectively. Accuracy and applicability of the optimized method was investigated by collecting saliva samples from smokers. Satisfactory percent recovery values wereachieved for cadmium with a low standard deviation in the acceptable range of 84.9-109.6 %. CONCLUSION The developed dispersive solvent-free S-SADF-LPME technique presents a fast, simple, cost-effective and eco-friendly microextraction method based on the use of an easily accessible and functional spray apparatus.
Collapse
Affiliation(s)
- Serkan Topal
- Istanbul University, TEBİP Programme, Chemistry Department, 34220, İstanbul, Turkey
| | - Meltem Şaylan
- Yıldız Technical University, Chemistry Department, 34220, İstanbul, Turkey
| | - Buse Tuğba Zaman
- Yıldız Technical University, Chemistry Department, 34220, İstanbul, Turkey
| | - Sezgin Bakırdere
- Yıldız Technical University, Chemistry Department, 34220, İstanbul, Turkey; Turkish Academy of Sciences (TÜBA), Vedat Dalokay Street, No:112, 06670, Çankaya, Ankara, Turkey.
| |
Collapse
|
29
|
A dispersive liquid–liquid microextraction method based on solidification of floating organic droplet for determination of antiviral agents in environmental water using HPLC/UV. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106790] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
30
|
Rosado T, Barroso M, Vieira DN, Gallardo E. Trends in microextraction approaches for handling human hair extracts - A review. Anal Chim Acta 2021; 1185:338792. [PMID: 34711317 DOI: 10.1016/j.aca.2021.338792] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2021] [Revised: 06/20/2021] [Accepted: 06/21/2021] [Indexed: 11/20/2022]
Abstract
The complementary role of hair in testing scenarios has expanded across the spectrum of toxicological and clinical monitoring investigations and, over the last 20 years, hair analysis has gained increasing attention and recognition. Moreover, a great deal of attention has been paid to the miniaturisation of extraction procedures, minimising/eliminating toxic organic solvents consumption, making them user-friendly and rapid, in addition to maximising extraction efficiency. The aim of this work is to provide a critical review of the advances observed over the last 5 years in the use of miniaturised approaches for sample clean-up and drug pre-concentration in hair analysis. There have been major improvements in some well-established microextraction approaches, such as liquid phase microextraction, mainly through the use of supramolecular and ionic liquids. In addition, new developments have also been reported in solid phase microextraction, driven by d-SPE applications. In the last 5 years, a total of 69 articles have been published using some type of microextraction technique for hair specimens, thus justifying the relevance of a critical review of innovations, improvements and trends related to these miniaturised approaches for sample preparation.
Collapse
Affiliation(s)
- Tiago Rosado
- Centro de Investigação em Ciências da Saúde (CICS-UBI), Universidade da Beira Interior, Covilhã, Portugal; Laboratório de Fármaco-Toxicologia - UBIMedical, Universidade da Beira Interior, Covilhã, Portugal; C4 - Cloud Computing Competence Centre, Universidade da Beira Interior, Covilhã, Portugal
| | - Mário Barroso
- Serviço de Química e Toxicologia Forenses, Instituto Nacional de Medicina Legal e Ciências Forenses, Delegação do Sul, Lisboa, Portugal
| | | | - Eugenia Gallardo
- Centro de Investigação em Ciências da Saúde (CICS-UBI), Universidade da Beira Interior, Covilhã, Portugal; Laboratório de Fármaco-Toxicologia - UBIMedical, Universidade da Beira Interior, Covilhã, Portugal.
| |
Collapse
|
31
|
Xue J, Yang L, Chen X, Bai XH, Hu S. Vortex-assisted dispersive liquid-phase microextraction for the analysis of main active compounds from Zi-Cao-Cheng-Qi decoction based on a hydrophobic deep eutectic solvent. J Sep Sci 2021; 44:4376-4383. [PMID: 34693642 DOI: 10.1002/jssc.202100270] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2021] [Revised: 10/18/2021] [Accepted: 10/19/2021] [Indexed: 01/25/2023]
Abstract
In this study, a vortex-assisted hydrophobic deep eutectic solvent dispersive liquid-phase microextraction was developed and used for the extraction and preconcentration of six main active compounds in Zi-Cao-Cheng-Qi decoction. The deep eutectic solvent, prepared by mixing tetrabutylammonium chloride and hexanoic acid at a molar ratio of 1:1, was added to the sample solution containing the analytes. In the absence of disperser, the extractant was rapidly dispersed into fine droplets by the aid of vortex and adequately contacted with the analytes. Some key parameters affecting the approach including extraction solvent type and volume, sample phase pH, extraction time, centrifugation time, and salt concentration were investigated and optimized. Under the optimum conditions, enrichment factors of the target analytes were in the range of 3-330. The calibration graphs were linear with a correlation coefficient (r) ≥ 0.9929. The detection limits were 0.3-0.9 ng/mL, and the satisfactory precisions (relative standard deviations, 0.5-8.9%) and accuracies (relative recoveries, 91.1-102.2%) were also obtained. The developed method was rapid (only 2 min), eco-friendly, effective, and easy to operate. And it has been successfully applied to simultaneous extraction, enrichment, and determination of the main active compounds in a traditional Chinese medicinal formula coupled with high-performance liquid chromatography.
Collapse
Affiliation(s)
- Jiao Xue
- School of Pharmacy, Shanxi Medical University, Taiyuan, P. R. China.,Cancer Institute, the Affiliated Hospital of Qingdao University, Qingdao University, Qingdao, P. R. China.,Qingdao Cancer Institute, Qingdao University, Qingdao, P. R. China
| | - Li Yang
- School of Pharmacy, Shanxi Medical University, Taiyuan, P. R. China
| | - Xuan Chen
- School of Pharmacy, Shanxi Medical University, Taiyuan, P. R. China
| | - Xiao-Hong Bai
- School of Pharmacy, Shanxi Medical University, Taiyuan, P. R. China
| | - Shuang Hu
- School of Pharmacy, Shanxi Medical University, Taiyuan, P. R. China
| |
Collapse
|
32
|
Agrawal A, Keçili R, Ghorbani-Bidkorbeh F, Hussain CM. Green miniaturized technologies in analytical and bioanalytical chemistry. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116383] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
33
|
Fischer C, Göen T. Determination of UV-327 and its metabolites in human urine using dispersive liquid-liquid microextraction and gas chromatography-tandem mass spectrometry. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:3978-3986. [PMID: 34528941 DOI: 10.1039/d1ay00932j] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
The benzotriazole UV stabilizer (BUVS) 2-(5-chloro-benzotriazol-2-yl)-4,6-di-(tert-butyl)phenol (UV-327) is added to plastic materials for UV protection. The compound is known to be ubiquitously distributed in the environment. We developed the first analytical method for the determination of UV-327 and seven metabolites, which were identified in vitro, in urine to be able to investigate the in vivo metabolism of UV-327 and to assess potential human exposure to the compound. Enzymatic hydrolysis of phase II conjugates is followed by sample purification with dispersive liquid-liquid microextraction (DLLME). The analytes are extracted from the urine samples after acidification with hydrochloric acid solution and addition of sodium chloride solution. Isopropyl alcohol and chloroform are used as disperser solvent and extraction solvent, respectively. After derivatization, the trimethylsilylated analytes are chromatographically separated and detected by gas chromatography coupled with tandem mass spectrometry (GC-MS/MS). To achieve maximum extraction of the analytes from the sample solution, the DLLME procedure was optimized with respect to the type and volume of disperser and extraction solvent, the pH value of the sample solution, the addition of salt, and the duration of vortex-mixing. Subsequent method validation demonstrated high sensitivity and reliability, with limits of detection (LODs) between 0.05 and 0.1 μg l-1 and mean relative recovery rates ranging from 88 to 112%. Precision and repeatability were proven by relative standard deviations ranging from 1 to 13% and from 5 to 14%, respectively.
Collapse
Affiliation(s)
- Corinna Fischer
- Institute and Outpatient Clinic of Occupational, Social and Environmental Medicine, Friedrich-Alexander-Universität Erlangen-Nürnberg, Henkestraße 9-11, 91054 Erlangen, Germany.
| | - Thomas Göen
- Institute and Outpatient Clinic of Occupational, Social and Environmental Medicine, Friedrich-Alexander-Universität Erlangen-Nürnberg, Henkestraße 9-11, 91054 Erlangen, Germany.
| |
Collapse
|
34
|
Li YJ, Ding WH. Determination of benzotriazole and benzothiazole derivatives in human urine by eco-friendly deep eutectic solvent-based ultrasound-assisted liquid-liquid microextraction followed by ultrahigh performance liquid chromatography quadrupole-time-of-flight mass spectrometry. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2021; 284:117530. [PMID: 34261225 DOI: 10.1016/j.envpol.2021.117530] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/03/2021] [Revised: 05/28/2021] [Accepted: 06/01/2021] [Indexed: 06/13/2023]
Abstract
Benzotriazole (BTRs) and benzothiazole (BTHs) derivatives have been classified as high production volume pollutants of emerging concern. The present work describes a rapid and simple process using an eco-friendly deep eutectic solvent (DES) based-ultrasound-assisted liquid-liquid microextraction (DES-UALLME) technique to effectively extract five BTRs and four BTHs in human urine samples, and then applying ultrahigh-performance liquid chromatography and electrospray ionization (+)-quadrupole time-of-flight mass spectrometry (UHPLC-ESI(+)-QTOF-MS) for their detection and quantification. DESs are a group of novel "green" solvents, and their applications in sample pretreatment are appropriate for the requirements for green chemistry, environmental protection and sustainable development. Furthermore, to overcome the challenges related to different experimental conditions, multivariate experimental design approaches conducted by means of a multilevel categorical design and a Box-Behnken Design were applied to screen and optimize parameters that have significant influences on the extraction efficiency of DES-UALLME. After optimization, the method was validated and shown to possess low limits of quantitation (LOQs; 0.4 - 9 ng mL-1), high precision (3-12%), and high accuracy (mean spiked recoveries; 80-101%). The developed method was then successfully applied for the analysis of BTRs and BTHs in human urine samples. Interestingly, 5,6-dimethyl-1H-benzotriazole (XTR) was detected in almost all of the urine samples, which correlates with its high production and widely applications in industry processes and consumer products in Taiwan. These target analytes could potentially be used as biomarkers to assess exposure of BTRs and BTHs in biomonitoring programs and studies.
Collapse
Affiliation(s)
- Yen-Jou Li
- Department of Chemistry, National Central University, Chung-Li, 320, Taiwan
| | - Wang-Hsien Ding
- Department of Chemistry, National Central University, Chung-Li, 320, Taiwan.
| |
Collapse
|
35
|
Recent Advances in Sample Preparation for Cosmetics and Personal Care Products Analysis. Molecules 2021; 26:molecules26164900. [PMID: 34443488 PMCID: PMC8399500 DOI: 10.3390/molecules26164900] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2021] [Revised: 08/10/2021] [Accepted: 08/11/2021] [Indexed: 11/19/2022] Open
Abstract
The use of cosmetics and personal care products is increasing worldwide. Their high matrix complexity, together with the wide range of products currently marketed under different forms imply a challenge for their analysis, most of them requiring a sample pre-treatment step before analysis. Classical sample preparation methodologies involve large amounts of organic solvents as well as multiple steps resulting in large time consumption. Therefore, in recent years, the trends have been moved towards the development of simple, sustainable, and environmentally friendly methodologies in two ways: (i) the miniaturization of conventional procedures allowing a reduction in the consumption of solvents and reagents; and (ii) the development and application of sorbent- and liquid-based microextraction technologies to obtain a high analyte enrichment, avoiding or significantly reducing the use of organic solvents. This review provides an overview of analytical methodology during the last ten years, placing special emphasis on sample preparation to analyse cosmetics and personal care products. The use of liquid–liquid and solid–liquid extraction (LLE, SLE), ultrasound-assisted extraction (UAE), solid-phase extraction (SPE), pressurized liquid extraction (PLE), matrix solid-phase extraction (MSPD), and liquid- and sorbent-based microextraction techniques will be reviewed. The most recent advances and future trends including the development of new materials and green solvents will be also addressed.
Collapse
|
36
|
Bai J, Xie LY, Yang L, Wang RQ, Chen X, Hu S. Reversed lipid micellar hollow-fiber liquid-phase microextraction of rotigotine in rat plasma. J Chromatogr B Analyt Technol Biomed Life Sci 2021; 1178:122583. [PMID: 34224964 DOI: 10.1016/j.jchromb.2021.122583] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2020] [Revised: 01/28/2021] [Accepted: 02/01/2021] [Indexed: 11/28/2022]
Abstract
A hollow fiber liquid phase microextraction (HF-LPME) based on a reversed lipid micelle as the extraction phase was proposed and combined with high performance liquid chromatography (HPLC) for the determination of rotigotine in biological matrix. In the proposed procedure, pieces of hollow fibers were fastened on a magnetic stir bar using a thread to provide better precision. Rotigotine was extracted from 5 mL of diluted plasma sample phase with pH 6 into reversed lipid micelle (5 mmol/L of dipalmitoyl phosphatidyl choline in n-octanol/water) impregnated in both the wall pores and the lumen of the hollow fiber. After the extraction at 900 rpm and room temperature for 30 min, the acceptor phase of reversed lipid micelle was collected for HPLC analysis. Various parameters affecting the extraction efficiency, such as type of surfactant and organic solvent, surfactant concentration, sample phase pH, salt amount, extraction time, stirring rate, and dilution factor of the plasma sample, were investigated and optimized. Furthermore, the formed reversed lipid micelle was characterized by fluorescence method. Under the optimal conditions, the linear range of rotigotine was between 2 ng/mL and 100 ng/mL with determination coefficient (r2) ≥ 0.9913. It is shown from results of method validation that the satisfactory accuracy (the relative errors between -8.5% and 3.3%), precision (the relative standard deviations from 3.8% to 8.9%), stability and matrix effect were obtained. The enrichment factor (EF) of the reversed lipid micelle-based HF-LPME for rotigotine reached 126. And the feasibility of the proposed method was confirmed by the application to the pharmacokinetic study of rotigotine in rat plasma.
Collapse
Affiliation(s)
- Jie Bai
- School of Pharmacy, Shanxi Medical University, Taiyuan 030001, PR China
| | - Li-Yuan Xie
- School of Pharmacy, Shanxi Medical University, Taiyuan 030001, PR China
| | - Li Yang
- School of Pharmacy, Shanxi Medical University, Taiyuan 030001, PR China
| | - Run-Qin Wang
- School of Pharmacy, Shanxi Medical University, Taiyuan 030001, PR China
| | - Xuan Chen
- School of Pharmacy, Shanxi Medical University, Taiyuan 030001, PR China
| | - Shuang Hu
- School of Pharmacy, Shanxi Medical University, Taiyuan 030001, PR China.
| |
Collapse
|
37
|
Determination of the Synthetic Antioxidants Butylated Hydroxyanisole (BHA) and Butylated Hydroxytoluene (BHT) by Matrix Acidity-Induced Switchable Hydrophilicity Solvent-Based Homogeneous Liquid-Liquid Microextraction (MAI-SHS-HLLME) and High-Performance Liquid Chromatography with Ultraviolet Detection (HPLC-UV). ANAL LETT 2021. [DOI: 10.1080/00032719.2021.1941072] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
38
|
Ammen EW, Al-Salihi S, Al-Salhi R. Gas Chromatography–Mass Spectrometry Combined with Successive Dilution for the Determination of Preservatives in Pharmaceuticals. JOURNAL OF ANALYTICAL CHEMISTRY 2021. [DOI: 10.1134/s1061934821050051] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
39
|
Kotowska U, Struk-Sokołowska J, Piekutin J. Simultaneous determination of low molecule benzotriazoles and benzotriazole UV stabilizers in wastewater by ultrasound-assisted emulsification microextraction followed by GC-MS detection. Sci Rep 2021; 11:10098. [PMID: 33980908 PMCID: PMC8114919 DOI: 10.1038/s41598-021-89529-1] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2021] [Accepted: 04/23/2021] [Indexed: 11/08/2022] Open
Abstract
A rapid, sensitive, economically and ecologically friendly method based on one-step ultrasound-assisted emulsification microextraction and in situ derivatization followed by gas chromatography-mass spectrometry for simultaneous determination of low molecular benzotriazoles and benzotriazole-based ultraviolet filters was developed. The optimized method allows quantification of benzotriazole, 4-methylbenzotriazole, 5-methylbenzotriazole; 5-chlorobenzotriazole, 2-(2'-hydroxy-3'-tert-butyl-5'-methylphenyl)-5-chlorobenzortriazole and 2-(2'-hydroxy-5'-(1,1,3,3-tetramethylbutyl)phenyl)benzotriazole in municipal and industrial (dairy) wastewater. The method was validated using real influent and effluent wastewater and samples at various stages of the purification process. Relative recoveries obtained using wastewater as sample matrix were between 77 and 137%, method limits of detection from 0.001 to 0.035 µg/L, method limits of quantification from 0.003 to 0.116 µg/L, the repeatability expressed by the coefficient of variation did not exceed 12%. The use of the method for the determination of tested compounds in municipal and industrial wastewater showed their presence in most of the tested samples, in concentrations from LoD to 6.110 µg/L. The conducted studies of samples from municipal wastewater treatment plant located in north-east Poland showed that the effectiveness of benzotriazole removal by this plant wasfrom 29 to 84%. The load of tested compounds released into the environment by this facility ranges from 2 to 269 mg/day/1000 inhabitants.
Collapse
Affiliation(s)
- Urszula Kotowska
- Department of Analytical and Inorganic Chemistry, Faculty of Chemistry, University of Bialystok, Ciołkowskiego 1K Street, 15-245, Białystok, Poland.
| | - Joanna Struk-Sokołowska
- Department of Environmental Engineering Technology, Faculty of Civil Engineering and Environmental Sciences, Bialystok University of Technology, Wiejska 45E, 15-351, Białystok, Poland
| | - Janina Piekutin
- Department of Environmental Engineering Technology, Faculty of Civil Engineering and Environmental Sciences, Bialystok University of Technology, Wiejska 45E, 15-351, Białystok, Poland
| |
Collapse
|
40
|
Ahmad SM, Gonçalves OC, Oliveira MN, Neng NR, Nogueira JMF. Application of Microextraction-Based Techniques for Screening-Controlled Drugs in Forensic Context-A Review. Molecules 2021; 26:2168. [PMID: 33918766 PMCID: PMC8070059 DOI: 10.3390/molecules26082168] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2021] [Revised: 04/03/2021] [Accepted: 04/06/2021] [Indexed: 01/12/2023] Open
Abstract
The analysis of controlled drugs in forensic matrices, i.e., urine, blood, plasma, saliva, and hair, is one of the current hot topics in the clinical and toxicological context. The use of microextraction-based approaches has gained considerable notoriety, mainly due to the great simplicity, cost-benefit, and environmental sustainability. For this reason, the application of these innovative techniques has become more relevant than ever in programs for monitoring priority substances such as the main illicit drugs, e.g., opioids, stimulants, cannabinoids, hallucinogens, dissociative drugs, and related compounds. The present contribution aims to make a comprehensive review on the state-of-the art advantages and future trends on the application of microextraction-based techniques for screening-controlled drugs in the forensic context.
Collapse
Affiliation(s)
- Samir M. Ahmad
- Centro de Química Estrutural, Faculdade de Ciências, Universidade de Lisboa, 1749-016 Lisboa, Portugal; (O.C.G.); (M.N.O.)
- Molecular Pathology and Forensic Biochemistry Laboratory, CiiEM, Campus Universitário—Quinta da Granja, Monte da Caparica, 2829-511 Caparica, Portugal
- Forensic and Psychological Sciences Laboratory Egas Moniz, Campus Universitário—Quinta da Granja, Monte da Caparica, 2829-511 Caparica, Portugal
| | - Oriana C. Gonçalves
- Centro de Química Estrutural, Faculdade de Ciências, Universidade de Lisboa, 1749-016 Lisboa, Portugal; (O.C.G.); (M.N.O.)
| | - Mariana N. Oliveira
- Centro de Química Estrutural, Faculdade de Ciências, Universidade de Lisboa, 1749-016 Lisboa, Portugal; (O.C.G.); (M.N.O.)
| | - Nuno R. Neng
- Centro de Química Estrutural, Faculdade de Ciências, Universidade de Lisboa, 1749-016 Lisboa, Portugal; (O.C.G.); (M.N.O.)
- Departamento de Química e Bioquímica, Faculdade de Ciências, Universidade de Lisboa, 1749-016 Lisboa, Portugal
| | - José M. F. Nogueira
- Centro de Química Estrutural, Faculdade de Ciências, Universidade de Lisboa, 1749-016 Lisboa, Portugal; (O.C.G.); (M.N.O.)
- Departamento de Química e Bioquímica, Faculdade de Ciências, Universidade de Lisboa, 1749-016 Lisboa, Portugal
| |
Collapse
|
41
|
Silveira GDO, Lourenço FR, Fonseca Pego AM, Guimarães Dos Santos R, Rossi GN, Hallak JEC, Yonamine M. Essential oil-based dispersive liquid-liquid microextraction for the determination of N,N-dimethyltryptamine and β-carbolines in human plasma: A novel solvent-free alternative. Talanta 2021; 225:121976. [PMID: 33592724 DOI: 10.1016/j.talanta.2020.121976] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2020] [Revised: 12/03/2020] [Accepted: 12/04/2020] [Indexed: 12/30/2022]
Abstract
The present study describes the development of a novel solvent-free vortex-assisted dispersive liquid-liquid microextraction alternative based on a natural essential oil as extracting solvent (VA-EO-DLLME) for the determination of N,N-dimethyltryptamine (DMT), harmine (HRM), harmaline (HRL) and tetrahydroarmine (THH) (compounds found in the ayahuasca tea, a psychedelic plant preparation) in human plasma. After optimization through full factorial and Box-Behnken experimental designs, this VA-EO-DLLME followed by ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) was completely validated and applied to authentic plasma specimens. Sample preparation consisted in the addition of 60 mg of NaCl, 100 μL of borate buffer and 100 μL of Eucalyptus globulus essential oil to a 200 μL aliquot of human plasma. After 30 s of vortex agitation followed by 5 min of centrifugation (10,000 rpm), 80 μL of the oil supernatant was dried and resuspended in mobile phase prior to injection into the UHPLC-MS/MS system. Once optimized, the validated method yielded LoDs ≤1.0 ng mL-1 for all analytes. LoQ was 1.0 ng mL-1 for DMT, HRL and HRM and 2.0 ng mL-1 for THH. The method has shown to be linear over the range of LoQ up to 150 ng mL-1 (r2 ≥ 0.9926). Intra/inter-day precision and accuracy met the acceptance criteria at three quality control (QC) levels. An additional intermediate precision study demonstrated that, except for THH and HRL at low and medium QCs, the overall method performance was similar for the three different oil sources. Matrix effect evaluation showed predominant ion suppression, ranging from 56% to 83%. Recovery varied from 33 up to 101% with an average of 50 ± 15.8%. Selectivity studies showed no interferences. Analysis of 13 authentic samples proved method feasibility. Finally, we believe that our novel VA-EO-DLLME approach offers a very simple, fast, cost-effective and eco-friendly alternative based on the use of an easily accessible and entirely green material as an extracting solvent. This may represent an incentive for researchers to investigate novel and creative alternatives, such as essential oils, as substitutes of organic solvents for microextraction methods in forensic and clinical contexts.
Collapse
Affiliation(s)
- Gabriela de Oliveira Silveira
- Department of Clinical and Toxicological Analyses, School of Pharmaceutical Sciences, University of São Paulo, São Paulo, 05508-000, Brazil.
| | - Felipe Rebello Lourenço
- Department of Pharmacy, School of Pharmaceutical Sciences, University of São Paulo, São Paulo, 05508-000, Brazil
| | | | - Rafael Guimarães Dos Santos
- Department of Neurosciences and Behaviour, University of São Paulo, Ribeirão Preto, 14049-900, Brazil; National Institute of Science and Technology-Translational Medicine, Ribeirão Preto, 14049-900, Brazil
| | - Giordano Novak Rossi
- Department of Neurosciences and Behaviour, University of São Paulo, Ribeirão Preto, 14049-900, Brazil
| | - Jaime E C Hallak
- Department of Neurosciences and Behaviour, University of São Paulo, Ribeirão Preto, 14049-900, Brazil; National Institute of Science and Technology-Translational Medicine, Ribeirão Preto, 14049-900, Brazil
| | - Mauricio Yonamine
- Department of Clinical and Toxicological Analyses, School of Pharmaceutical Sciences, University of São Paulo, São Paulo, 05508-000, Brazil.
| |
Collapse
|
42
|
He Y, Miggiels P, Wouters B, Drouin N, Guled F, Hankemeier T, Lindenburg PW. A high-throughput, ultrafast, and online three-phase electro-extraction method for analysis of trace level pharmaceuticals. Anal Chim Acta 2021; 1149:338204. [DOI: 10.1016/j.aca.2021.338204] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2020] [Revised: 12/29/2020] [Accepted: 01/04/2021] [Indexed: 12/24/2022]
|
43
|
Jagirani MS, Ozalp O, Soylak M. New Trend in the Extraction of Pesticides from the Environmental and Food Samples Applying Microextraction Based Green Chemistry Scenario: A Review. Crit Rev Anal Chem 2021; 52:1343-1369. [PMID: 33560139 DOI: 10.1080/10408347.2021.1874867] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
This review focused on the green microextraction methods used for the extraction of pesticides from the environmental and food samples. Microextraction techniques have been explored and applied in various fields of analytical chemistry since its beginning, as evinced by the numerous reviews published. The success of any technique in science and technology is measured by the simplicity, environmentally friendly, and its applications; and the microextraction technique is highly successive. Deliberations were attentive to studies where efforts have been made to validate the methods through the inter-laboratory comparison study to assess the analytical performance of microextraction techniques against conventional methods. Succinctly, developed microextraction methods are shown to impart significant benefits over conventional techniques. Provided that the analytical community continues to put forward attention and resources into the growth and validation of the microextraction technique, a promising future for microextraction is forecasted.
Collapse
Affiliation(s)
- Muhammad Saqaf Jagirani
- Faculty of Sciences, Department of Chemistry, Erciyes University, Kayseri, Turkey.,National Center of Excellence in Analytical Chemistry, University of Sindh, Sindh, Pakistan
| | - Ozgur Ozalp
- Faculty of Sciences, Department of Chemistry, Erciyes University, Kayseri, Turkey.,Technology Research and Application Center (TAUM), Erciyes University, Kayseri, Turkey
| | - Mustafa Soylak
- Faculty of Sciences, Department of Chemistry, Erciyes University, Kayseri, Turkey.,Technology Research and Application Center (TAUM), Erciyes University, Kayseri, Turkey
| |
Collapse
|
44
|
Silva LK, Rangel JHG, Brito NM, Sousa ER, Sousa ÉML, Lima DLD, Esteves VI, Freitas AS, Silva GS. Solidified floating organic drop microextraction (SFODME) for the simultaneous analysis of three non-steroidal anti-inflammatory drugs in aqueous samples by HPLC. Anal Bioanal Chem 2021; 413:1851-1859. [PMID: 33469709 DOI: 10.1007/s00216-021-03153-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2020] [Revised: 12/09/2020] [Accepted: 01/04/2021] [Indexed: 02/08/2023]
Abstract
In this work, a liquid-liquid microextraction methodology using solidified floating organic drop (SFODME) was combined with liquid chromatography and UV/Vis detection to determine non-steroidal anti-inflammatory drugs (NSAIDs) naproxen (NPX), diclofenac (DCF), and mefenamic acid (MFN) in tap water, surface water, and seawater samples. Parameters that can influence the efficiency of the process were evaluated, such as the type and volume of the extractor and dispersive solvents, effect of pH, agitation type, and ionic strength. The optimized method showed low detection limits (0.09 to 0.25 μg L-1), satisfactory recovery rates (90 to 116%), and enrichment factors in the range between 149 and 199. SFODME showed simplicity, low cost, speed, and high concentration capacity of the analytes under study. Its use in real samples did not demonstrate a matrix effect that would compromise the effectiveness of the method, being possible to apply it successfully in water samples with different characteristics.
Collapse
Affiliation(s)
- Lanna K Silva
- Department of Chemistry, Federal Institute of Education, Science and Technology of Maranhão, Monte Castelo Campus, Getúlio Vargas Avenue, São Luis, 65030-005, Brazil.
| | - José H G Rangel
- Department of Chemistry, Federal Institute of Education, Science and Technology of Maranhão, Monte Castelo Campus, Getúlio Vargas Avenue, São Luis, 65030-005, Brazil
| | - Natilene M Brito
- Department of Chemistry, Federal Institute of Education, Science and Technology of Maranhão, Monte Castelo Campus, Getúlio Vargas Avenue, São Luis, 65030-005, Brazil
| | - Eliane R Sousa
- Department of Chemistry, Federal Institute of Education, Science and Technology of Maranhao, Maracanã Campus, Av. dos Curiós, Vila Esperança, São Luis, 65095-460, Brazil
| | - Érika M L Sousa
- CESAM, Department of Chemistry, University of Aveiro, Campus Universitario de Santiago, 3810-193, Aveiro, Portugal
| | - Diana L D Lima
- CESAM, Department of Chemistry, University of Aveiro, Campus Universitario de Santiago, 3810-193, Aveiro, Portugal
| | - Valdemar I Esteves
- CESAM, Department of Chemistry, University of Aveiro, Campus Universitario de Santiago, 3810-193, Aveiro, Portugal
| | - Arlan S Freitas
- Department of Chemistry, Federal Institute of Education, Science and Technology of Maranhão, Monte Castelo Campus, Getúlio Vargas Avenue, São Luis, 65030-005, Brazil
| | - Gilmar S Silva
- Department of Chemistry, Federal Institute of Education, Science and Technology of Maranhão, Monte Castelo Campus, Getúlio Vargas Avenue, São Luis, 65030-005, Brazil
| |
Collapse
|
45
|
Dias RA, Sousa ER, Silva GS, Silva LK, Freitas AS, Lima DL, Sousa ÉM. Ultrasound-assisted dispersive liquid-liquid microextraction for determination of enrofloxacin in surface waters. Microchem J 2021. [DOI: 10.1016/j.microc.2020.105633] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
46
|
Suliman MA, Olarewaju TA, Basheer C, Lee HK. Microextraction and its application for petroleum and crude oil samples. J Chromatogr A 2020; 1636:461795. [PMID: 33340743 DOI: 10.1016/j.chroma.2020.461795] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2020] [Revised: 12/05/2020] [Accepted: 12/08/2020] [Indexed: 11/24/2022]
Abstract
Petroleum is an extremely heterogeneous material. It consists of a wide range of aliphatic, aromatic, and compounds containing heteroatoms such as metals, sulfur, and nitrogen. The American Society for Testing and Materials (ASTM) methods are used globally as accepted analytical methods for petroleum, petrochemicals, and fuels. A major drawback of ASTM methods is that they require multistep sample preparation that consumes substantial volumes of samples. Thus, the challenge in the petrochemical analysis is to develop rapid and simpler sample preparation procedures that can be automated. An assessment based on the current literature, specifically on the sample preparation of petroleum samples, leads to the authors' conclusion that microextraction provides an excellent complement to current methods. In this review, solvent and sorbent-based microextraction techniques in the context of the consideration of petroleum and crude oil, and samples related to the petrochemical industry, are discussed.
Collapse
Affiliation(s)
- Mohammed Altahir Suliman
- Department of Chemistry, King Fahd University of Petroleum and Minerals, Dhahran 31261, Saudi Arabia
| | | | - Chanbasha Basheer
- Department of Chemistry, King Fahd University of Petroleum and Minerals, Dhahran 31261, Saudi Arabia.
| | - Hian Kee Lee
- Department of Chemistry, National University of Singapore, 3 Science Drive 3, Singapore 117543, Singapore
| |
Collapse
|
47
|
Gissawong N, Mukdasai S, Boonchiangma S, Sansuk S, Srijaranai S. A rapid and simple method for the removal of dyes and organophosphorus pesticides from water and soil samples using deep eutectic solvent embedded sponge. CHEMOSPHERE 2020; 260:127590. [PMID: 32679376 DOI: 10.1016/j.chemosphere.2020.127590] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/06/2020] [Revised: 06/28/2020] [Accepted: 07/01/2020] [Indexed: 06/11/2023]
Abstract
A new treatment method using a deep eutectic solvent embedded melamine sponge (DES-MS) was studied for the removal of organic pollutants from water and soil samples. Five organophosphorus pesticides (OPPs) consisting of azinphos-methyl (AZP), parathion-methyl (PRT), fenitrothion (FNT), diazinon (DIZ) and chlorpyrifos (CPF), and two dyes including acid blue 29 (AB29) and malachite green (MG) were used as the model pollutants. DESs were easily prepared from tetrabutylammonium bromide (TBABr) and various fatty acids. The synthesised DESs were loaded into the sponge before being utilized for the removal of the studied pollutants. After the removal, the residual OPPs or dyes in the supernatant was quantified by high performance liquid chromatography or derivative spectrophotometry, respectively. The proposed method was simple, rapid, environmentally friendly and effective with the removal efficiency higher than 70% for various samples. Moreover, the removal of various dyes was successfully achieved with the efficiency greater than 65% under the optimum condition.
Collapse
Affiliation(s)
- Netsirin Gissawong
- Materials Chemistry Research Center, Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Khon Kaen University, Khon Kaen, 40002, Thailand
| | - Siriboon Mukdasai
- Materials Chemistry Research Center, Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Khon Kaen University, Khon Kaen, 40002, Thailand
| | - Suthasinee Boonchiangma
- Materials Chemistry Research Center, Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Khon Kaen University, Khon Kaen, 40002, Thailand
| | - Sira Sansuk
- Materials Chemistry Research Center, Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Khon Kaen University, Khon Kaen, 40002, Thailand
| | - Supalax Srijaranai
- Materials Chemistry Research Center, Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Khon Kaen University, Khon Kaen, 40002, Thailand.
| |
Collapse
|
48
|
Silveira GDO, Lourenço FR, Bruno V, Yonamine M. Fast Hollow Fiber Liquid-Phase Microextraction as a Greener Alternative for the Determination of N,N-Dimethyltryptamine and Harmala Alkaloids in Human Urine. Front Chem 2020; 8:558501. [PMID: 33134270 PMCID: PMC7575737 DOI: 10.3389/fchem.2020.558501] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2020] [Accepted: 09/08/2020] [Indexed: 01/16/2023] Open
Abstract
Ayahuasca tea is an entheogen hallucinogenic beverage used for shamanic and spiritual purposes, prepared by the decoction of different Amazonian plants containing N,N-dimethyltryptamine (DMT) and harmala alkaloids. Since the therapeutic potential of this tea has been broadly studied in recent years, mainly for the treatment of psychiatric disorders, the determination of the ayahuasca tea components in human and animal matrices is of utmost importance. In order to avoid the use of large amounts of toxic solvents, typically employed in traditional sample preparation methods, hollow fiber liquid-phase microextraction (HF-LPME) presents a greener and time-saving alternative. The present study aims to fully develop and apply an HF-LPME method for the determination of DMT, harmine (HRM), harmaline (HRL), and tetrahydroharmine (THH) in human urine samples using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Fractional factorial and Box–Behnken designs were used to identify and optimize significant method variables. Once optimized, validation has shown a limit of detection (LoD) of 1.0 ng/ml for DMT and 2.0 ng/ml for the harmala alkaloid. The limit of quantification (LoQ) was of 5.0 ng/ml for all analytes. The method has shown to be linear over a concentration range of 5–200 ng/ml (r2 ≥ 0.99). Intra/inter-day precision and accuracy met the acceptance criteria at the three quality control (QC) levels studied (15.0, 90.0, and 170.0 ng/ml, n = 6, each). Matrix effect evaluation showed predominant ion enhancement and recovery values were above 80%. Dilution factors of 10- and 20-fold have shown acceptable values of accuracy. Selectivity studies showed no interferences. Analysis of eight authentic samples collected from four subjects proved method feasibility. A simple, time-saving and green alternative for the analysis of DMT and harmala alkaloids in human urine samples was developed, optimized using design of experiments, fully validated and applied to authentic samples.
Collapse
Affiliation(s)
- Gabriela de Oliveira Silveira
- Department of Clinical and Toxicological Analyses, School of Pharmaceutical Sciences, University of São Paulo, São Paulo, Brazil
| | - Felipe Rebello Lourenço
- Department of Pharmacy, School of Pharmaceutical Sciences, University of São Paulo, São Paulo, Brazil
| | - Vitor Bruno
- Department of Clinical and Toxicological Analyses, School of Pharmaceutical Sciences, University of São Paulo, São Paulo, Brazil
| | - Mauricio Yonamine
- Department of Clinical and Toxicological Analyses, School of Pharmaceutical Sciences, University of São Paulo, São Paulo, Brazil
| |
Collapse
|
49
|
Yu C, Zhang A, Wang G, Wang T, Shan J. Gastropylor complex capsules vs. micro ecological preparation in children with diarrhea. Minerva Med 2020; 111:517-519. [DOI: 10.23736/s0026-4806.19.06140-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
50
|
Application of Hollow Fibre-Liquid Phase Microextraction Technique for Isolation and Pre-Concentration of Pharmaceuticals in Water. MEMBRANES 2020; 10:membranes10110311. [PMID: 33137884 PMCID: PMC7693864 DOI: 10.3390/membranes10110311] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Revised: 09/14/2020] [Accepted: 09/17/2020] [Indexed: 12/12/2022]
Abstract
In this article, a comprehensive review of applications of the hollow fibre-liquid phase microextraction (HF-LPME) for the isolation and pre-concentration of pharmaceuticals in water samples is presented. HF-LPME is simple, affordable, selective, and sensitive with high enrichment factors of up to 27,000-fold reported for pharmaceutical analysis. Both configurations (two- and three-phase extraction systems) of HF-LPME have been applied in the extraction of pharmaceuticals from water, with the three-phase system being more prominent. When compared to most common sample preparation techniques such as solid phase extraction, HF-LPME is a greener analytical chemistry process due to reduced solvent consumption, miniaturization, and the ability to automate. However, the automation comes at an added cost related to instrumental set-up, but a reduced cost is associated with lower reagent consumption as well as shortened overall workload and time. Currently, many researchers are investigating ionic liquids and deep eutectic solvents as environmentally friendly chemicals that could lead to full classification of HF-LPME as a green analytical procedure.
Collapse
|