1
|
Chiang JCB, Tajbakhsh Z, Wolffsohn JS. The clinical impact of contact lens wear on neural structure and function of the cornea. Clin Exp Optom 2024:1-11. [PMID: 39250904 DOI: 10.1080/08164622.2024.2401511] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2024] [Revised: 08/13/2024] [Accepted: 09/01/2024] [Indexed: 09/11/2024] Open
Abstract
Contact lens (CL) use is growing rapidly, with a current estimate of over 100 million wearers worldwide. Vast improvements in materials and designs have occurred over the past decades with advancements in the understanding of ocular surface health with CL wear. However, the potential impact of CL on neural structures and function of the ocular surface, particularly in relation to the richly innervated cornea, remain poorly understood. Problems with sensation such as CL discomfort and conditions that may be associated with lens wear including dry eye disease also remain pervasive. This narrative review discusses the findings from studies involving soft or rigid CL wearers, assessed with c linical techniques designed for examining the neural integrity of the cornea, namely in vivo confocal microscopy and esthesiometry. While the collective findings remain equivocal in terms of the changes in corneal nerve morphology and function with conventional CL wear, more specialised CLs, namely orthokeratology lenses, which mechanically manipulates the structure of the cornea seem to produce more prominent changes in nerve distribution and sensitivity reduction. Given the intricate relationship between neural and immune mechanisms in maintaining balanced ocular surface health, the potential links between these structural and functional findings with parainflammation and neuroinflammation, as well as clinical issues including CL discomfort and dry eye disease, are also explored.
Collapse
Affiliation(s)
| | - Zahra Tajbakhsh
- Department of Optometry, University of Western Australia, Crawley, Australia
| | | |
Collapse
|
2
|
Situ P, Begley C, Simpson T. The roles of neural adaptation and sensitization in contact lens discomfort. Ocul Surf 2024; 34:132-139. [PMID: 39047906 DOI: 10.1016/j.jtos.2024.07.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2024] [Revised: 07/03/2024] [Accepted: 07/11/2024] [Indexed: 07/27/2024]
Abstract
PURPOSE To investigate the roles of neural adaptation and sensitization in contact lens discomfort (CLD). METHODS Cooling stimuli (20 °C) were applied to the cornea in a group comprising 24 symptomatic and 25 asymptomatic contact lens (CL) wearers as well as 15 non-CL wearing controls, using a computerized Belmonte esthesiometer. The adaptation paradigm consisted of 20 repetitive stimuli at threshold, sub- and supra-threshold levels. The sensitization paradigm involved five levels of suprathreshold stimuli ranging between 1x to 2x threshold. Following each stimulus, participants rated the sensation magnitude regarding intensity, coolness and irritation. Measurements were taken with habitual CL (BL_CL), after 2 weeks of no-CL (No_CL) and after restarting habitual CL wear (ReSt_CL). RESULTS The symptomatic subjects exhibited a lower threshold but reported enhanced sensations during the adaptation and sensitization paradigm, compared to the asymptomatic and control groups (all p ≤ 0.021). At the BL_CL and ReSt_CL visits, they showed increased ratings to repeated subthreshold stimuli (p = 0.025) and greater irritation during the sensitization paradigm (p ≤ 0.032). Ratings in asymptomatic and control groups were relatively unchanged over time (p ≥ 0.181). Logistic regression revealed a link between the augmented sensory responses and increased likelihood with CLD. CONCLUSION The maladaptive sensory responses seen in CLD subjects, with reduced adaptation and heightened sensitization to ocular surface stimulation, suggest an imbalance between sensitization and adaptation in CLD. As CLD may represent a reversible subcategory of dry eye, it can serve as a human dry eye model for studying the neurosensory effect of ocular surface stimulation.
Collapse
Affiliation(s)
- Ping Situ
- School of Optometry, Indiana University, Bloomington, IN, USA.
| | - Carolyn Begley
- School of Optometry, Indiana University, Bloomington, IN, USA
| | - Trefford Simpson
- School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| |
Collapse
|
3
|
Nosch DS, Käser E, Bracher T, Joos RE. Clinical application of the Swiss Liquid Jet Aesthesiometer for corneal sensitivity measurement. Clin Exp Optom 2024; 107:14-22. [PMID: 37019837 DOI: 10.1080/08164622.2023.2191782] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Accepted: 03/10/2023] [Indexed: 04/07/2023] Open
Abstract
CLINICAL RELEVANCE Corneal sensitivity represents an important indicator for corneal health, its innervation and hence also for ocular disease. It is therefore of great interest from a clinical and research perspective to quantify ocular surface sensation. BACKGROUND The aim of this prospective cross-sectional cohort study was to clinically test the within-day and day-to-day repeatability of the new Swiss Liquid Jet Aesthesiometer, employing small droplets of isotonic saline solution for repeatability, and correlate with the Cochet-Bonnet aesthesiometer in a cohort of participants of two different age groups, based on participant feedback (psychophysical method). METHODS Participants were recruited from two equally, large age groups: group A (18-30 years) and group B (50-70 years). The inclusion criteria were healthy eyes, Ocular Surface Disease Index (OSDI) ≤ 13, and no contact lens wear. Mechanical corneal sensitivity threshold measurements with means of liquid jet and Cochet-Bonnet methods were carried out twice during two visits (a total of four measurements), with a stimulus temperature equal to or slightly above the ocular surface temperature. RESULTS Ninety participants completed the study (n = 45 per age group, average age in group A: 24.2 ± 2.94 years, group B: 58.5 ± 5.71 years). The coefficient of repeatability for the liquid jet method was 2.56 dB within visits and 3.61 between visits. For the Cochet-Bonnet method, it was 2.27 dB within visits and 4.42 dB between visits (Bland Altman with bootstrap analysis). Moderate correlation was observed between the liquid jet and the Cochet-Bonnet method (r = 0.540, p < .001, robust linear regression). CONCLUSIONS Swiss liquid jet aesthesiometry offers a new examiner independent method for corneal sensitivity measurement with acceptable repeatability and moderate correlation with the Cochet-Bonnet aesthesiometer. It offers a large stimulus pressure range of 100-1500 mbar and a precision of 1 mbar. Stimulus intensity can be tuned more precisely and much smaller sensitivity fluctuations may be potentially detected.
Collapse
Affiliation(s)
- Daniela S Nosch
- Institute of Optometry, University of Applied Sciences and Arts Northwestern Switzerland (FHNW), Olten, Switzerland
| | | | - Tobias Bracher
- Institute of Optometry, University of Applied Sciences and Arts Northwestern Switzerland (FHNW), Olten, Switzerland
| | - Roland E Joos
- Institute of Optometry, University of Applied Sciences and Arts Northwestern Switzerland (FHNW), Olten, Switzerland
| |
Collapse
|
4
|
Pastor-Zaplana JÁ, Gallar J, Acosta MC. Functional Changes of the Ocular Surface Sensory Nerves Due to Contact Lens Use in Young Symptomatic and Asymptomatic Users. Invest Ophthalmol Vis Sci 2023; 64:12. [PMID: 37938935 PMCID: PMC10637199 DOI: 10.1167/iovs.64.14.12] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2023] [Accepted: 10/18/2023] [Indexed: 11/10/2023] Open
Abstract
Purpose The purpose of this study was to analyze the differences in corneal sensory nerve functionality in young asymptomatic (CL-A) and symptomatic (CL-S) contact lens (CL) users. Methods CL wearers (23.8 ± 1.0 years, n = 31) were classified as CL-S with an Ocular Surface Disease Index (OSDI) ≥ 13 (n = 14) or CL-A. Users of eye glasses (EG; 24.5 ± 0.8 years, n = 29) with OSDI < 13 participated as controls. The sensations evoked by mechanical, chemical (gas esthesiometer), and cold (4°C saline drops) stimuli were measured using the Visual Analogue Scales (VASs). Moreover, tear volume, tear break up time (TBUT), blinking frequency (BF), and ocular surface temperature (OST; IR thermography) were also measured. Results Mechanical and chemical stimuli produced similar scores in the CL-A and EG participants, although the CL-A subjects referred to stronger irritation (p < 0.05). Likewise, the VAS intensity in response to cold stimuli did not differ between CL-A and EG subjects, while the ability to detect cold was significantly worse in CL-S users (p < 0.05). CL-A users had a similar tear volume, a higher BF (p < 0.01) and shorter TBUT (p < 0.001) to EG wearers, and blinking and TBUT were also altered significantly in CL-S users (p < 0.01). Interestingly, the OST was significantly lower in CL-A users (p < 0.05) than in EG wearers, but not in CL-S users. Conclusions Using CLs modifies corneal sensitivity, blinking and tearing in young volunteers. Even if they have yet to develop clinical signs of inflammation, they display changes in corneal sensitivity consistent with the sensitization of corneal nociceptors and the inhibition cold thermoreceptors, phenomena that occur under inflammatory conditions. The differences in corneal sensitivity and OST between CL-A and CL-S users could reflect the extent of nerve damage and inflammation at the ocular surface.
Collapse
Affiliation(s)
- José Ángel Pastor-Zaplana
- Instituto de Neurociencias, Universidad Miguel Hernández-CSIC, Sant Joan d'Alacant, Spain
- Departamento de Patología y Cirugía, Universidad Miguel Hernández de Elche, Sant Joan d'Alacant, Spain
| | - Juana Gallar
- Instituto de Neurociencias, Universidad Miguel Hernández-CSIC, Sant Joan d'Alacant, Spain
- Instituto de Investigación Biomédica y Sanitaria de Alicante, Alicante, Spain
| | - M. Carmen Acosta
- Instituto de Neurociencias, Universidad Miguel Hernández-CSIC, Sant Joan d'Alacant, Spain
| |
Collapse
|
5
|
Kim YH, Graham AD, Li W, Dursch TJ, Peng CC, Radke CJ, Lin MC. Tear-film evaporation flux and its relationship to tear properties in symptomatic and asymptomatic soft-contact-lens wearers. Cont Lens Anterior Eye 2023; 46:101850. [PMID: 37137757 DOI: 10.1016/j.clae.2023.101850] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2022] [Revised: 02/18/2023] [Accepted: 04/17/2023] [Indexed: 05/05/2023]
Abstract
PURPOSE With soft-contact-lens wear, evaporation of the pre-lens tear film affects the osmolarity of the post-lens tear film and this can introduce a hyperosmotic environment at the corneal epithelium, leading to discomfort. The purposes of the study are to ascertain whether there are differences in evaporation flux (i.e., the evaporation rate per unit area) between symptomatic and asymptomatic soft-contact-lens wearers, to assess the repeatability of a flow evaporimeter, and to assess the relationship between evaporation fluxes, tear properties, and environmental conditions. METHODS Closed-chamber evaporimeters commonly used in ocular-surface research do not control relative humidity and airflow, and, therefore, misestimate the actual tear-evaporation flux. A recently developed flow evaporimeter overcomes these limitations and was used to measure accurate in-vivo tear-evaporation fluxes with and without soft-contact-lens wear for symptomatic and asymptomatic habitual contact-lens wearers. Concomitantly, lipid-layer thickness, ocular-surface-temperature decline rate (i.e., °C/s), non-invasive tear break-up time, tear-meniscus height, Schirmer tear test, and environmental conditions were measured in a 5 visit study. RESULTS Twenty-one symptomatic and 21 asymptomatic soft-contact-lens wearers completed the study. A thicker lipid layer was associated with slower evaporation flux (p < 0.001); higher evaporation flux was associated with faster tear breakup irrespective of lens wear (p = 0.006). Higher evaporation flux was also associated with faster ocular-surface-temperature decline rate (p < 0.001). Symptomatic lens wearers exhibited higher evaporation flux than did asymptomatic lens wearers, however, the results did not reach statistical significance (p = 0.053). Evaporation flux with lens wear was higher than without lens wear but was also not statistically significant (p = 0.110). CONCLUSIONS The repeatability of the Berkeley flow evaporimeter, associations between tear characteristics and evaporation flux, sample-size estimates, and near statistical significance in tear-evaporation flux between symptomatic and asymptomatic lens wearers all suggest that with sufficient sample sizes, the flow evaporimeter is a viable research tool to understand soft-contact-lens wear comfort.
Collapse
Affiliation(s)
- Young Hyun Kim
- Herbert Wertheim School of Optometry & Vision Science, University of California, Berkeley, CA 94720, United States; Clinical Research Center, Herbert Wertheim School of Optometry & Vision Science, University of California, Berkeley, CA 94720, United States; Chemical and Biomolecular Engineering Department, University of California, Berkeley, CA 94720, United States
| | - Andrew D Graham
- Clinical Research Center, Herbert Wertheim School of Optometry & Vision Science, University of California, Berkeley, CA 94720, United States
| | - Wing Li
- Herbert Wertheim School of Optometry & Vision Science, University of California, Berkeley, CA 94720, United States; Clinical Research Center, Herbert Wertheim School of Optometry & Vision Science, University of California, Berkeley, CA 94720, United States
| | - Thomas J Dursch
- Clinical Research Center, Herbert Wertheim School of Optometry & Vision Science, University of California, Berkeley, CA 94720, United States; Chemical and Biomolecular Engineering Department, University of California, Berkeley, CA 94720, United States
| | - Cheng-Chun Peng
- Clinical Research Center, Herbert Wertheim School of Optometry & Vision Science, University of California, Berkeley, CA 94720, United States; Chemical and Biomolecular Engineering Department, University of California, Berkeley, CA 94720, United States; CooperVision Inc., Pleasanton, CA 94588, United States
| | - Clayton J Radke
- Herbert Wertheim School of Optometry & Vision Science, University of California, Berkeley, CA 94720, United States; Chemical and Biomolecular Engineering Department, University of California, Berkeley, CA 94720, United States
| | - Meng C Lin
- Herbert Wertheim School of Optometry & Vision Science, University of California, Berkeley, CA 94720, United States; Clinical Research Center, Herbert Wertheim School of Optometry & Vision Science, University of California, Berkeley, CA 94720, United States.
| |
Collapse
|
6
|
Ghalibafan S, Osei K, Amescua G, Sabater A. Efficacy of Plasma Rich in Growth Factors (PRGF) in Stage 1 Neurotrophic Keratitis. RESEARCH SQUARE 2023:rs.3.rs-3040369. [PMID: 37461454 PMCID: PMC10350222 DOI: 10.21203/rs.3.rs-3040369/v1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/24/2023]
Abstract
Background/Aims Neurotrophic keratitis (NK) is a neurodegenerative disease that can lead to corneal hypoesthesia, decreased tear production, and epitheliopathy. Based on the severity of ocular surface damage, NK is classified into 3 stages. Stage 1 NK is characterized by superficial punctate keratopathy, tear film instability, and reduced corneal sensation. The therapeutic efficacy of PRGF eye drops for NK stages 2 and 3 has been previously reported. In this study, we evaluated the efficacy and safety of autologous PRGF eye drops in improving corneal sensitivity and other ocular surface clinical signs in patients with stage 1 NK. Methods Retrospective chart review. Results 26 eyes of 15 stage 1 NK patients (seven males, eight females), aged 76.3 ± 12.1 years, were included in the study. The mean treatment duration was 2 ± 1.8 months. With PRGF treatment, corneal sensitivity increased from 2.8 to 4.5 cm in 53.8% (14/26) (p < 0.01), TBUT increased from 3.6 to 5.0 s in 69.2% (18/26) (p < 0.01), and Schirmer score increased from 13.7 to 16.8 mm in 80.7% (21/26) of treated eyes (p < 0.01). Similarly, an improvement in corneal staining (punctate epithelial erosions) and MMP-9 levels was seen in 80.7% (n = 21) and 65.4% (n = 17) of treated eyes, respectively. BCVA improvement was seen in 26.9% of treated eyes (n = 7). Conclusions This study demonstrates the effective role of PRGF therapy in recovering corneal sensation and tear film function and in the healing of corneal erosions in stage 1 NK patients.
Collapse
Affiliation(s)
| | - Kwaku Osei
- University of Miami Miller School of Medicine
| | - Guillermo Amescua
- Bascom Palmer Eye institute, University of Miami, Miller School of Medicine
| | | |
Collapse
|
7
|
Kang Y, Hu Q, Li X, Guo Z, Wu Q, Zhang H. Role of tear vasoactive intestinal peptide on dry eyes after laser keratorefractive surgery. BMC Ophthalmol 2023; 23:167. [PMID: 37081425 PMCID: PMC10116093 DOI: 10.1186/s12886-023-02857-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2022] [Accepted: 03/13/2023] [Indexed: 04/22/2023] Open
Abstract
BACKGROUND To explore the changes in vasoactive intestinal peptide (VIP) concentration in tears post laser-assisted sub-epithelial keratomileusis (LASEK) and femtosecond laser-assisted in situ keratomileusis (FS-LASIK) surgeries and related factors, possible association between postoperative dry eye symptoms and VIP concentration in tears, and factors influencing dry eye symptoms after different periods post LASEK and FS-LASIK surgeries. METHODS In this prospective, non-randomized, longitudinal cohort study, 23 and 22 subjects were recruited and underwent LASEK and FS-LASIK, respectively. After conducting an intact ophthalmic examination and collecting relevant surgical data, all subjects were examined for VIP concentration in their tears using ELISAs, tear-film breakup time, ocular staining and ocular surface disease index questionnaire before surgery and 1 day, 1 week, and 1 month post-surgery. RESULTS Tear VIP concentration increased significantly after both LASEK and FS-LASIK, with the highest concentration observed 1 week post-surgery (P ≤ 0.05). Tear VIP concentration correlated negatively with corneal ablation depth (AD). The extent of dry eyes was related to the operation method employed and postoperative recovery period. In FS-LASIK and LASEK subjects, dry eyes were mainly affected by the basic ocular surface status before surgery, and VIP concentration. Furthermore, in LASEK subjects, dry eyes were negatively correlated with AD. CONCLUSION VIP was stimulated and mobilized as an emergency protection post-refractive surgery and a trauma model affected by AD. It can indirectly indicate the inevitable relationship between postoperative dry eye and nerve injury. Elevated post-surgery tear VIP relieves dry eye symptoms, showing its neuroimmune role in regulating adverse injury stimulation. The present study provides a solution to the pathogenesis of postoperative dry eyes. TRIAL REGISTRATION The trial registration number: 2021JS22. Date of registration: 10 May 2021.
Collapse
Affiliation(s)
- Yang Kang
- Eye Hospital, The First Affiliated Hospital of Harbin Medical University, No. 143, Yiman Street, 150001, Harbin, Heilongjiang Province, People's Republic of China
| | - Qi Hu
- Eye Hospital, The First Affiliated Hospital of Harbin Medical University, No. 143, Yiman Street, 150001, Harbin, Heilongjiang Province, People's Republic of China
| | - Xue Li
- Eye Hospital, The First Affiliated Hospital of Harbin Medical University, No. 143, Yiman Street, 150001, Harbin, Heilongjiang Province, People's Republic of China
| | - Zidan Guo
- Outpatient department of Harbin Medical University, Harbin Medical University, Harbin, Heilongjiang Province, People's Republic of China
| | - Qiong Wu
- Eye Hospital, The First Affiliated Hospital of Harbin Medical University, No. 143, Yiman Street, 150001, Harbin, Heilongjiang Province, People's Republic of China
| | - Hong Zhang
- Eye Hospital, The First Affiliated Hospital of Harbin Medical University, No. 143, Yiman Street, 150001, Harbin, Heilongjiang Province, People's Republic of China.
| |
Collapse
|
8
|
Capote-Puente R, Sánchez-González JM, Sánchez-González MC, Bautista-Llamas MJ. Evaluation of Celligent® Biomimetic Water Gradient Contact Lens Effects on Ocular Surface and Subjective Symptoms. Diagnostics (Basel) 2023; 13:diagnostics13071258. [PMID: 37046476 PMCID: PMC10093668 DOI: 10.3390/diagnostics13071258] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Revised: 03/20/2023] [Accepted: 03/26/2023] [Indexed: 03/30/2023] Open
Abstract
This study aimed to evaluate the non-invasive and subjective symptoms associated with Lehfilcon A water gradient silicone hydrogel contact lenses with bacterial and lipid resistance technology. A prospective, longitudinal, single-centre, self-controlled study was conducted among silicone hydrogel contact lens wearers. Non-invasive analysis of the pre-lens tear film was performed using the Integrated Clinical Platform (ICP) Ocular Surface Analyzer (OSA), and the meibomian glands were evaluated with the Cobra® HD infrared meibographer. After 30 days of contact lens wear, the subjects were re-evaluated to determine the changes in conjunctival redness, subjective dry eye disease, tear meniscus height, lipid pattern, and non-invasive break-up time. Results showed that the lipid layer thickness decreased significantly from 2.05 ± 1.53 to 0.92 ± 1.09 Guillon patterns, and the tear meniscus height decreased from 0.21 ± 0.04 to 0.14 ± 0.03. The mean pre-lens non-invasive break-up time (NIBUT) significantly increased from 15.19 ± 9.54 to 25.31 ± 15.81 s. The standard Patient Evaluation of Eye Disease (SPEED) score also decreased from 7.39 ± 4.39 to 5.53 ± 4.83. The results suggest that Lehfilcon A significantly reduced lipid and aqueous tear film volume but improved break-up time and subjective dry eye symptoms.
Collapse
Affiliation(s)
- Raúl Capote-Puente
- Optica Area, Vision Research Group (CIVIUS), Department of Physics of Condensed Matter, Faculty of Pharmacy, University of Seville, 41012 Seville, Spain
| | - José-María Sánchez-González
- Optica Area, Vision Research Group (CIVIUS), Department of Physics of Condensed Matter, Faculty of Pharmacy, University of Seville, 41012 Seville, Spain
| | - María Carmen Sánchez-González
- Optica Area, Vision Research Group (CIVIUS), Department of Physics of Condensed Matter, Faculty of Pharmacy, University of Seville, 41012 Seville, Spain
| | - María-José Bautista-Llamas
- Optica Area, Vision Research Group (CIVIUS), Department of Physics of Condensed Matter, Faculty of Pharmacy, University of Seville, 41012 Seville, Spain
| |
Collapse
|
9
|
Guo R, Jiang J, Zhang Y, Liang Q, Chen T, Hu K. Evaluation of corneal dendritic cell density and subbasal nerve density in contact lens wearers using IVCM: A systematic review and meta-analysis. Front Med (Lausanne) 2023; 10:1149803. [PMID: 36993811 PMCID: PMC10040792 DOI: 10.3389/fmed.2023.1149803] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2023] [Accepted: 02/27/2023] [Indexed: 03/14/2023] Open
Abstract
PurposeTo evaluate the subclinical changes in corneal dendritic cell density (CDCD) and corneal subbasal nerve density (CSND) in asymptomatic contact lens (CL) wearers.MethodsDatabases including PubMed, Scopus, Web of Science, and Cochrane Central Register of Controlled Trials were searched for trials and studies reporting the changes of corneal CDCD and CSND in contact lens wearers published until 25 June 2022. PRISMA guidelines as well as recommended meta-analysis practices were followed. Meta-analysis was conducted using RevMan V.5.3 software.ResultsAfter the screening, 10 studies with 587 eyes of 459 participants were included. Seven studies reported the data of CDCD. Compared with the control group, CDCD in the CL wearers was higher (18.19, 95% CI 18.8–27.57, p = 0.0001). Type of in vivo confocal microscopy (IVCM), wear duration, and frequency of lens change were sources of heterogeneity. The difference in CSND between CL wearers and the control group was insignificant, and subgroup analysis did not reveal a source of heterogeneity.ConclusionOverall, CDCD increased in CL wears, while CSND did not show significant differences. IVCM is a feasible tool to assess subclinical changes in CL wearers.
Collapse
|
10
|
Zhang Z, Lu S, Jiang Y, Sun S. Assessing the corneal sub-basal nerve plexus by in vivo confocal microscopy in patients with blepharoptosis. Ann Med 2022; 54:227-234. [PMID: 35014936 PMCID: PMC8757600 DOI: 10.1080/07853890.2021.2024246] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/01/2022] Open
Abstract
BACKGROUND To assess in vivo confocal microscopy features of corneal sub-basal nerve plexus in patients with congenital or aponeurogenic blepharoptosis using a fully automated software (ACCMetrics). PATIENTS AND METHODS This prospective study included 33 patients with blepharoptosis and 17 normal controls. The corneal sub-basal nerve plexus was assessed using in vivo confocal microscopy, and the ocular surface status was evaluated by tear break-up times. RESULTS The mean age of 33 patients with blepharoptosis and 17 normal controls were 38.77 ± 22.81 years and 48.35 ± 17.15 years, respectively. The mean duration of blepharoptosis was 16.42 ± 15.60 years. In 13 patients with unilateral blepharoptosis, there was no significant difference between affected eyes and contralateral eyes (all ps > .05), except for wider corneal nerve fibre width (CNFW) in affected eyes (0.024 ± 0.001 versus 0.023 ± 0.001 mm/mm2, p = .021). In 20 patients with bilateral blepharoptosis, there was no significant difference between the eyes. No significant difference was detected between 19 cases with congenital blepharoptosis and 14 cases with aponeurogenic blepharoptosis. When compared with normal controls, eyes with both unilateral and bilateral blepharoptosis had significantly wider CNFW. But from the point of aetiology, only eyes with congenital blepharoptosis presented with wider CNFW (p = .001), rather than the eyes with aponeurogenic blepharoptosis (p = .093). Besides, four young patients with congenital blepharoptosis revealed very sparse sub-basal nerve plexus. CONCLUSIONS These data suggested that corneal confocal microscopy demonstrated no significant changes in patients with blepharoptosis as compared with normal controls, except for relatively wider CNFW in congenital affected eyes. However, in some children and young adults with congenital blepharoptosis, the density of corneal sub-basal nerve plexus was evidently decreased, which needs to be cautioned when ones with congenital blepharoptosis want to take corneal surgeries or wear contact lens.Key messagesWhen compared with normal controls, no significant effect was found in the influence of blepharoptosis on the most of corneal nerve parameters, except for corneal nerve fibre width (CNFW) in the group of congenital blepharoptosis.The age of onset of blepharoptosis may influence corneal nerve fibres, so timely surgical treatment of congenital blepharoptosis is not only conducive to the development of normal vision, but also beneficial to the reduction of corneal nerve lesions to some extent.We noted that some young blepharoptosis patients revealed sparse corneal nerve, which should be taken precaution when ones with congenital blepharoptosis who want to take corneal surgeries or wear contact lens.
Collapse
Affiliation(s)
- Zhengwei Zhang
- Department of Ophthalmology, Affiliated Wuxi Clinical College of Nantong University, Wuxi, People's Republic of China.,Department of Ophthalmology, The Affiliated Wuxi No. 2 People's Hospital of Nanjing Medical University, Wuxi, People's Republic of China
| | - Shui Lu
- Department of Ophthalmology, Affiliated Wuxi Clinical College of Nantong University, Wuxi, People's Republic of China.,Department of Ophthalmology, The Affiliated Wuxi No. 2 People's Hospital of Nanjing Medical University, Wuxi, People's Republic of China
| | - Yunjia Jiang
- Department of Ophthalmology, Affiliated Wuxi Clinical College of Nantong University, Wuxi, People's Republic of China.,Department of Ophthalmology, The Affiliated Wuxi No. 2 People's Hospital of Nanjing Medical University, Wuxi, People's Republic of China
| | - Song Sun
- Department of Ophthalmology, Affiliated Wuxi Clinical College of Nantong University, Wuxi, People's Republic of China.,Department of Ophthalmology, The Affiliated Wuxi No. 2 People's Hospital of Nanjing Medical University, Wuxi, People's Republic of China
| |
Collapse
|
11
|
Chao C, Tajbakhsh Z, Stapleton F, Mobeen R, Madigan MC, Jalbert I, Briggs N, Golebiowski B. Corneal epithelial dendritic cells, tear neuropeptides and corneal nerves continue to be affected more than 12 months after LASIK. Acta Ophthalmol 2022; 101:e302-e314. [PMID: 36250753 DOI: 10.1111/aos.15270] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2022] [Revised: 09/21/2022] [Accepted: 09/24/2022] [Indexed: 11/30/2022]
Abstract
PURPOSE LASIK causes corneal nerve damage and may affect the neuro-immune crosstalk. This study examined the effects of LASIK on corneal epithelial dendritic cells (CEDC) density and morphology and explored their relationships with corneal nerves and tear neuropeptides. A grading system was developed to assess CEDC morphology. METHODS Intra- and inter-observer repeatability of the CEDC morphology grading system was established using kappa (κ). In vivo confocal microscope images of the central cornea were captured from 20 participants who had undergone LASIK 12-16 months earlier and 20 controls (age 18-32 years, 55%F). CEDC density was counted manually, and CEDC morphology was assessed using a new grading system. CEDC sub-types (contacting nerves [CEDCc] and not contacting nerves [CEDCnc]) were also assessed. Differences in CEDC density and morphology were examined using mixed models and chi-squared test. Relationships between CEDC and corneal nerve parameters and tear substance P were explored using Spearman's correlation. RESULTS Excellent intra- and inter-observer repeatability was demonstrated for the grading system (κ = 0.82-0.97). In post-LASIK participants, CEDC density was lower compared with controls (5 [0-34] vs. 21 [7-77] cells/mm2 ; p = 0.01), and the proportion of CEDC with thick dendrites was higher (55%-73% vs. 11%-21%, p < 0.003). Higher tear substance P levels were associated with higher CEDC density (rho = 0.48, p = 0.003). Fewer nerve interconnections were observed in participants in whom CEDC had dendrites (p = 0.03). CEDC sub-types followed a similar pattern to CEDC. CONCLUSIONS The findings suggest that CEDC may remain altered more than 12 months post-LASIK. The association with substance P suggests a role for CEDC in corneal neurogenic inflammation.
Collapse
Affiliation(s)
- Cecilia Chao
- School of Optometry and Vision Science, UNSW Sydney, Sydney, Australia
| | - Zahra Tajbakhsh
- School of Optometry and Vision Science, UNSW Sydney, Sydney, Australia
| | - Fiona Stapleton
- School of Optometry and Vision Science, UNSW Sydney, Sydney, Australia
| | - Rabia Mobeen
- School of Optometry and Vision Science, UNSW Sydney, Sydney, Australia
| | - Michele C Madigan
- School of Optometry and Vision Science, UNSW Sydney, Sydney, Australia.,Save Sight Institute, University of Sydney, Sydney, Australia
| | - Isabelle Jalbert
- School of Optometry and Vision Science, UNSW Sydney, Sydney, Australia
| | - Nancy Briggs
- Stats Central, Mark Wainwright Analytical Centre, UNSW Sydney, Sydney, Australia
| | | |
Collapse
|
12
|
Ren X, Chou Y, Wang Y, Jing D, Chen Y, Li X. The Utility of Oral Vitamin B1 and Mecobalamin to Improve Corneal Nerves in Dry Eye Disease: An In Vivo Confocal Microscopy Study. Nutrients 2022; 14:nu14183750. [PMID: 36145126 PMCID: PMC9504679 DOI: 10.3390/nu14183750] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2022] [Revised: 09/03/2022] [Accepted: 09/08/2022] [Indexed: 11/24/2022] Open
Abstract
Our purpose is to demonstrate the changes in cornea nerve parameters and symptoms and signs in dry eye disease (DED) patients after oral vitamin B1 and mecobalamin treatment. In this randomized double-blind controlled trial, DED patients were randomly assigned to either the treatment group (oral vitamin B1 and mecobalamin, artificial tears) or the control group (artificial tears). Corneal nerve parameters via in vivo confocal microscopy (IVCM), DED symptoms, and signs were assessed at baseline and 1 and 3 months post-treatment. In total, 398 eyes from 199 patients were included. In the treatment group, there were significant improvements in corneal nerve length, width, and neuromas, the sign of conjunctival congestion score (CCS), symptoms of dryness, pain, photophobia, blurred vision, total symptom score, and OSDI (OSDI) at 1/3 months post-treatment (all p < 0.05). Patients who received vitamin B1 and mecobalamin showed greater improvement in CCS, dryness scores at 1 month (p < 0.05), corneal fluorescein staining (CFS) (p = 0.012), photophobia (p = 0.032), total symptom scores (p = 0.041), and OSDI (p = 0.029) at 3 months. Greater continuous improvement in CFS (p = 0.045), dryness (p = 0.033), blurred vision (p = 0.031) and total symptom scores (p = 0.023) was demonstrated at 3 months than at 1 month post-treatment in the treatment group. We found that oral vitamin B1 and mecobalamin can improve corneal nerve length, width, reflectivity and the number of neuromas in IVCM, thereby repairing epithelial cells and alleviating some ocular symptoms. Thus, vitamin B1 and mecobalamin are potential treatment options for patients with DED.
Collapse
Affiliation(s)
- Xiaotong Ren
- Department of Ophthalmology, Peking University Third Hospital, Beijing 100191, China
| | - Yilin Chou
- Department of Ophthalmology, BenQ Medical Center, The Affiliated BenQ Hospital of Nanjing Medical University, Nanjing 210000, China
| | - Yuexin Wang
- Department of Ophthalmology, Peking University Third Hospital, Beijing 100191, China
| | - Dalan Jing
- Department of Ophthalmology, Peking University Third Hospital, Beijing 100191, China
| | - Yanyan Chen
- Department of Ophthalmology, Daqing Oilfield General Hospital, Daqing 163311, China
| | - Xuemin Li
- Department of Ophthalmology, Peking University Third Hospital, Beijing 100191, China
- Correspondence: ; Tel.: +86-15611908409
| |
Collapse
|
13
|
Kamm K. CGRP and Migraine: What Have We Learned From Measuring CGRP in Migraine Patients So Far? Front Neurol 2022; 13:930383. [PMID: 35968305 PMCID: PMC9363780 DOI: 10.3389/fneur.2022.930383] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2022] [Accepted: 06/21/2022] [Indexed: 11/13/2022] Open
Abstract
The multi-functional neuropeptide calcitonin gene-related peptide (CGRP) plays a major role in the pathophysiology of migraine. The detection of elevated CGRP levels during acute migraine headache was the first evidence of the importance of the peptide. Since then, elevated CGRP levels have been detected not only during spontaneous and experimentally induced migraine attacks but also interictally. However, the detection of CGRP in peripheral blood shows conflicting results. In this respect, alternative detection methods are needed and have been already proposed. This article summarizes what we have learned from studies investigating CGRP in jugular and peripheral blood and reviews the latest state of research concerning the detection of CGRP in saliva and tear fluid as well as their contribution to our understanding of migraine pathophysiology.
Collapse
|
14
|
Clinical Report: Midday Removal and Reinsertion of Soft Contact Lens Cannot Prevent Post-lens Tear-film Hyperosmolarity. Optom Vis Sci 2022; 99:652-654. [PMID: 35849056 DOI: 10.1097/opx.0000000000001923] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
SIGNIFICANCE Our analysis shows that post-lens tear-film hyperosmolarity is not preventable with midday removal and reinsertion of soft contact lenses. However, low lens-salt diffusivity can prevent the post-lens tear film from becoming hyperosmotic. Lens-salt diffusivity should be lowered to minimize post-lens tear-film osmolarity while also avoiding lens adhesion. PURPOSE Soft contact lenses with high lens-salt diffusivity result in hyperosmotic post-lens tear films (PoLTF). If the time it takes for PoLTF osmolarity to reach periodic steady state is multiple hours, simple midday lens removal and reinsertion can prevent the PoLTF from becoming hyperosmotic. We investigate whether midday removal and reinsertion of a soft contact lens can prevent the PoLTF from becoming hyperosmotic. METHODS Time to periodic steady state for PoLTF osmolarity upon soft-contact-lens wear is determined with a previously developed transient tear-dynamics continuum model. Interblink period, lens-salt diffusivity, and lens thickness were varied to assess their effects on time to periodic steady state for PoLTF osmolarity. Time to periodic steady states were assessed for both normal and dry eyes. RESULTS Within the physically realistic ranges of lens-salt diffusivity, lens thickness, and interblink period, PoLTF osmolarity reaches the periodic steady state well within the first hour of lens wear for both normal and dry eyes. Time to periodic steady state for PoLTF osmolarity is predominately dictated by the salt transport across the contact lens between the PoLTF and the pre-lens tear film and water transport from the ocular surface to the PoLTF. CONCLUSIONS Since the time to periodic steady state is less than one hour for physically realistic ranges of lens-salt diffusivity, interblink period, and lens thickness, midday lens removal and reinsertion cannot prevent PoLTF hyperosmolarity. Instead, focus should be on using soft contact lenses with low salt diffusivity to prevent PoLTF hyperosmolarity.
Collapse
|
15
|
Evaluation of Ocular Surface Characteristics in Dry Eye Disease With and Without Soft Contact Lens Wear: A Comparative Study. Eye Contact Lens 2022; 48:377-383. [PMID: 35583308 DOI: 10.1097/icl.0000000000000904] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/21/2022] [Indexed: 11/25/2022]
Abstract
OBJECTIVES To investigate ocular surface alterations and in vivo confocal microscopic characteristics of the cornea in dry eye disease (DED) with contact lens wear (CLW). METHODS Sixty participants were divided into three groups: DED with CLW (n=20), DED without CLW (n=20), and normal control (n=20). Ocular surface parameters were evaluated. Basal tears and in vivo confocal microscopy images of the cornea were collected. Multiplex bead analysis was used to assess interleukin (IL)-6, IL-1β, tumor necrosis factor (TNF)-α, nerve growth factor (NGF), and substance P (SP) in tears. Nerve morphology and dendritic cell density in corneal subbasal nerve images were calculated. RESULTS The DED with CLW group showed significantly higher ocular surface staining scores (P=0.022) and higher levels of IL-1β, NGF, and SP in tears (P=0.014, P=0.004 and P=0.025) than the DED without CLW group. Corneal dendritic cell density in the DED with CLW group was significantly higher than that in the normal controls (P=0.001) and DED without CLW group (P=0.043). Tear cytokine levels of IL-1β, NGF, and SP were correlated with ocular surface parameters in the DED with CLW group. Moreover, the years of CLW were positively correlated with corneal dendritic cell density (r=0.527, P=0.017) and negatively correlated with corneal nerve density (r=-0.511, P=0.021). CONCLUSIONS Patients with DED with CLW showed greater epithelial damage, elevated inflammatory cytokines and neuromediators in tears, and higher corneal dendritic cell density than patients with DED without CLW. The immune and nervous systems may be involved in contact lens-related DED.
Collapse
|
16
|
Soifer M, Tovar A, Wang M, Mousa HM, Yennam S, Sabater AL, Pflugfelder S, Perez VL. A multicenter report of the use of plasma rich in growth factors (PRGF) for the treatment of patients with ocular surface diseases in North America. Ocul Surf 2022; 25:40-48. [PMID: 35489588 DOI: 10.1016/j.jtos.2022.04.007] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2022] [Revised: 04/22/2022] [Accepted: 04/23/2022] [Indexed: 12/31/2022]
Abstract
PURPOSE To investigate the efficacy and safety of plasma rich in growth factors (PRGF) eyedrops in the management of patients with ocular surface diseases in North America. METHODS Multicenter interventional case series of patients using PRGF eyedrops for the first time. A cohort of patients was analyzed for corneal staining score at initial visit and at 3 months of therapy with PRGF. Another cohort responded to a 10-item questionnaire that evaluated patients' satisfaction and safety, which included the symptom assessment questionnaire in dry eye (SANDE) score, after 6 months of PRGF treatment. RESULTS A total of 153 patients were analyzed. Of these, 102 were reviewed for corneal epitheliopathy and 99 patients responded to the questionnaire. The mean (±SD) age of the population was 63.7 ± 17 years and 72.5% were female. The clinical indications for PRGF usage were dry eye (60%), neurotrophic keratopathy (15%), dormant corneal ulcers (12%), limbal stem cell deficiency (10%), and cicatrizing conjunctivitis (4%). At the final visit, 74.3% of patients showed an improvement of their corneal staining. Those who had punctate epithelial erosions or epithelial defects were reduced from 76.5% to 47% and 23.5%-7.8% respectively (p < 0.0001). Symptoms, measured via SANDE score, significantly decreased from a median of 90 to 34.6 out of 100 points on follow-up (p < 0.0001). Only one patient (0.98%) complained of ocular burning sensation as a side effect. CONCLUSIONS This multicentric study demonstrates the safety and efficacy of the use of PRGF for treating signs and symptoms in patients with significant ocular surface diseases.
Collapse
Affiliation(s)
- Matias Soifer
- Department of Ophthalmology, Duke Eye Center, Duke University School of Medicine, Durham, NC, USA
| | - Arianna Tovar
- Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Margaret Wang
- Department of Ophthalmology, Baylor College of Medicine, Houston, TX, USA
| | - Hazem M Mousa
- Department of Ophthalmology, Duke Eye Center, Duke University School of Medicine, Durham, NC, USA
| | - Sowmya Yennam
- Department of Ophthalmology, Baylor College of Medicine, Houston, TX, USA
| | - Alfonso L Sabater
- Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA
| | | | - Victor L Perez
- Department of Ophthalmology, Duke Eye Center, Duke University School of Medicine, Durham, NC, USA.
| |
Collapse
|
17
|
Osae EA, Jones L, Nichols JJ. The impact of contact lenses on meibomian gland morphology. Ocul Surf 2022; 24:148-155. [PMID: 35395385 DOI: 10.1016/j.jtos.2022.04.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2021] [Revised: 02/22/2022] [Accepted: 04/02/2022] [Indexed: 11/28/2022]
Abstract
Despite years of experience with contact lenses, controversy remains as to whether contact lenses adversely impact the meibomian glands (MG). This review summarizes the present body of evidence, showing that contact lens wear is associated with alterations in MG morphology (up to 80% higher gland atrophy compared to non-wearers) and qualitative changes in MG secretion. Key factors such as duration of contact lens wear, contact lens type (e.g., soft vs. rigid), edge design, and material modulus of elasticity are discussed in relation to the extent of MG morphological changes, the quality of MG secretion and other ocular surface parameters. Longitudinal studies of sufficient statistical power are needed to better understand how contact lens wear affects the MG, risk factors, and the clinical sequelae of these changes.
Collapse
Affiliation(s)
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, Ontario, Canada; Centre for Eye and Vision Research (CEVR), 17W Hong Kong Science Park, Hong Kong
| | - Jason J Nichols
- The University of Alabama at Birmingham, School of Optometry, Birmingham, AL, 35233, USA.
| |
Collapse
|
18
|
Insua Pereira E, Sampaio AP, Lira M. Effects of contact lens wear on tear inflammatory biomarkers. Cont Lens Anterior Eye 2022; 45:101600. [DOI: 10.1016/j.clae.2022.101600] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Revised: 04/13/2022] [Accepted: 04/15/2022] [Indexed: 11/25/2022]
|
19
|
Tear film and ocular surface neuropeptides: Characteristics, synthesis, signaling and implications for ocular surface and systemic diseases. Exp Eye Res 2022; 218:108973. [PMID: 35149082 DOI: 10.1016/j.exer.2022.108973] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2021] [Revised: 12/14/2021] [Accepted: 02/01/2022] [Indexed: 01/13/2023]
Abstract
Ocular surface neuropeptides are vital molecules primarily involved in maintaining ocular surface integrity and homeostasis. They also serve as communication channels between the nervous system and the immune system, maintaining the homeostasis of the ocular surface. Tear film and ocular surface neuropeptides have a role in disease often due to abnormalities in their synthesis (either high or low production), signaling through defective receptors, or both. This creates imbalances in otherwise normal physiological processes. They have been observed to be altered in many ocular surface and systemic diseases including dry eye disease, ocular allergy, keratoconus, LASIK-induced dry eye, pterygium, neurotrophic keratitis, corneal graft rejection, microbial keratitis, headaches and diabetes. This review examines the characteristics of neuropeptides, their synthesis and their signaling through G-protein coupled receptors. The review also explores the types of neuropeptides within the tears and ocular surface, and how they change in ocular and systemic diseases.
Collapse
|
20
|
Zhan X, Li J, Guo Y, Golubnitschaja O. Mass spectrometry analysis of human tear fluid biomarkers specific for ocular and systemic diseases in the context of 3P medicine. EPMA J 2021; 12:449-475. [PMID: 34876936 PMCID: PMC8639411 DOI: 10.1007/s13167-021-00265-y] [Citation(s) in RCA: 46] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2021] [Accepted: 11/03/2021] [Indexed: 12/23/2022]
Abstract
Over the last two decades, a large number of non-communicable/chronic disorders reached an epidemic level on a global scale such as diabetes mellitus type 2, cardio-vascular disease, several types of malignancies, neurological and eye pathologies-all exerted system's enormous socio-economic burden to primary, secondary, and tertiary healthcare. The paradigm change from reactive to predictive, preventive, and personalized medicine (3PM/PPPM) has been declared as an essential transformation of the overall healthcare approach to benefit the patient and society at large. To this end, specific biomarker panels are instrumental for a cost-effective predictive approach of individualized prevention and treatments tailored to the person. The source of biomarkers is crucial for specificity and reliability of diagnostic tests and treatment targets. Furthermore, any diagnostic approach preferentially should be noninvasive to increase availability of the biomaterial, and to decrease risks of potential complications as well as concomitant costs. These requirements are clearly fulfilled by tear fluid, which represents a precious source of biomarker panels. The well-justified principle of a "sick eye in a sick body" makes comprehensive tear fluid biomarker profiling highly relevant not only for diagnostics of eye pathologies but also for prediction, prognosis, and treatment monitoring of systemic diseases. One prominent example is the Sicca syndrome linked to a cascade of severe complications that include dry eye, neurologic, and oncologic diseases. In this review, protein profiles in tear fluid are highlighted and corresponding biomarkers are exemplified for several relevant pathologies, including dry eye disease, diabetic retinopathy, cancers, and neurological disorders. Corresponding analytical approaches such as sample pre-processing, differential proteomics, electrophoretic techniques, high-performance liquid chromatography (HPLC), enzyme-linked immuno-sorbent assay (ELISA), microarrays, and mass spectrometry (MS) methodology are detailed. Consequently, we proposed the overall strategies based on the tear fluid biomarkers application for 3P medicine practice. In the context of 3P medicine, tear fluid analytical pathways are considered to predict disease development, to target preventive measures, and to create treatment algorithms tailored to individual patient profiles.
Collapse
Affiliation(s)
- Xianquan Zhan
- Shandong Key Laboratory of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University, 440 Jiyan Road, Jinan, 250117 Shandong China
- Medical Science and Technology Innovation Center, Shandong First Medical University, 6699 Qingdao Road, Jinan, 250117 Shandong China
- Gastroenterology Research Institute and Clinical Center, Shandong First Medical University, 38 Wuying Shan Road, Jinan, Shandong 250031 People’s Republic of China
| | - Jiajia Li
- Medical Science and Technology Innovation Center, Shandong First Medical University, 6699 Qingdao Road, Jinan, 250117 Shandong China
- Key Laboratory of Cancer Proteomics of Chinese Ministry of Health, Xiangya Hospital, Central South University, 87 Xiangya Road, Changsha, 410008 Hunan China
| | - Yuna Guo
- Medical Science and Technology Innovation Center, Shandong First Medical University, 6699 Qingdao Road, Jinan, 250117 Shandong China
| | - Olga Golubnitschaja
- Predictive, Preventive and Personalised (3P) Medicine, Department of Radiation Oncology, University Hospital Bonn, Rheinische Friedrich-Wilhelms-University of Bonn, Sigmund-Freud-Str 25, 53105 Bonn, Germany
| |
Collapse
|
21
|
Yang LWY, Mehta JS, Liu YC. Corneal neuromediator profiles following laser refractive surgery. Neural Regen Res 2021; 16:2177-2183. [PMID: 33818490 PMCID: PMC8354117 DOI: 10.4103/1673-5374.308666] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2020] [Revised: 11/02/2020] [Accepted: 01/22/2021] [Indexed: 01/07/2023] Open
Abstract
Laser refractive surgery is one of the most commonly performed procedures worldwide. In laser refractive surgery, Femtosecond Laser in Situ Keratomileusis and Refractive Lenticule Extraction have emerged as promising alternatives to microkeratome Laser in Situ Keratomileusis and Photorefractive Keratectomy. Following laser refractive surgery, the corneal nerves, epithelial and stromal cells release neuromediators, including neurotrophins, neuropeptides and neurotransmitters. Notably, nerve growth factor, substance P, calcitonin gene-related peptide and various cytokines are important mediators of neurogenic inflammation and corneal nerve regeneration. Alterations in neuromediator profiles and ocular surface parameters following laser refractive surgery are attributed to the surgical techniques and the severity of tissue insult induced. In this review, we will discuss the (1) Functions of neuromediators and their physiological and clinical significance; (2) Changes in the neuromediators following various laser refractive surgeries; (3) Correlation between neuromediators, ocular surface health and corneal nerve status; and (4) Future directions, including the use of neuromediators as potential biomarkers for ocular surface health following laser refractive surgery, and as adjuncts to aid in corneal regeneration after laser refractive surgery.
Collapse
Affiliation(s)
- Lily Wei Yun Yang
- Yong Loo Lin School of Medicine, National University of Singapore, Singapore
- Tissue Engineering and Cell Therapy Group, Singapore Eye Research Institute, Singapore
| | - Jodhbir S. Mehta
- Tissue Engineering and Cell Therapy Group, Singapore Eye Research Institute, Singapore
- Department of Cornea and External Eye Disease, Singapore National Eye Centre, Singapore
- Ophthalmology and Visual Sciences Academic Clinical Program, Duke-NUS Medical School, Singapore
| | - Yu-Chi Liu
- Tissue Engineering and Cell Therapy Group, Singapore Eye Research Institute, Singapore
- Department of Cornea and External Eye Disease, Singapore National Eye Centre, Singapore
- Ophthalmology and Visual Sciences Academic Clinical Program, Duke-NUS Medical School, Singapore
| |
Collapse
|
22
|
Protection against corneal hyperosmolarity with soft-contact-lens wear. Prog Retin Eye Res 2021; 87:101012. [PMID: 34597771 DOI: 10.1016/j.preteyeres.2021.101012] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2021] [Revised: 09/18/2021] [Accepted: 09/21/2021] [Indexed: 01/03/2023]
Abstract
Hyperosmotic tear stimulates human corneal nerve endings, activates ocular immune response, and elicits dry-eye symptoms. A soft contact lens (SCL) covers the cornea preventing it from experiencing direct tear evaporation and the resulting blink-periodic salinity increases. For the cornea to experience hyperosmolarity due to tear evaporation, salt must transport across the SCL to the post-lens tear film (PoLTF) bathing the cornea. Consequently, limited salt transport across a SCL potentially protects the ocular surface from hyperosmotic tear. In addition, despite lens-wear discomfort sharing common sensations to dry eye, no correlation is available between measured tear hyperosmolarity and SCL-wear discomfort. Lack of documentation is likely because clinical measurements of tear osmolarity during lens wear do not interrogate the tear osmolarity of the PoLTF that actually overlays the cornea. Rather, tear osmolarity is clinically measured in the tear meniscus. For the first time, we mathematically quantify tear osmolarity in the PoLTF and show that it differs significantly from the clinically measured tear-meniscus osmolarity. We show further that aqueous-deficient dry eye and evaporative dry eye both exacerbate the hyperosmolarity of the PoLTF. Nevertheless, depending on lens salt-transport properties (i.e., diffusivity, partition coefficient, and thickness), a SCL can indeed protect against corneal hyperosmolarity by reducing PoLTF salinity to below that of the ocular surface during no-lens wear. Importantly, PoLTF osmolarity for dry-eye patients can be reduced to that of normal eyes with no-lens wear provided that the lens exhibits a low lens-salt diffusivity. Infrequent blinking increases PoLTF osmolarity consistent with lens-wear discomfort. Judicious design of SCL material salt-transport properties can ameliorate corneal hyperosmolarity. Our results confirm the importance of PoLTF osmolarity during SCL wear and indicate a possible relation between PoLTF osmolarity and contact-lens discomfort.
Collapse
|
23
|
Hwang DDJ, Lee SJ, Kim JH, Lee SM. The Role of Neuropeptides in Pathogenesis of Dry Dye. J Clin Med 2021; 10:4248. [PMID: 34575359 PMCID: PMC8471988 DOI: 10.3390/jcm10184248] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2021] [Revised: 09/07/2021] [Accepted: 09/14/2021] [Indexed: 12/29/2022] Open
Abstract
Neuropeptides are known as important mediators between the nervous and immune systems. Recently, the role of the corneal nerve in the pathogenesis of various ocular surface diseases, including dry eye disease, has been highlighted. Neuropeptides are thought to be important factors in the pathogenesis of dry eye disease, as suggested by the well-known role between the nervous and immune systems, and several recently published studies have elucidated the previously unknown pathogenic mechanisms involved in the role of the neuropeptides secreted from the corneal nerves in dry eye disease. Here, we reviewed the emerging concept of neurogenic inflammation as one of the pathogenic mechanisms of dry eye disease, the recent results of related studies, and the direction of future research.
Collapse
Affiliation(s)
- Daniel Duck-Jin Hwang
- Department of Ophthalmology, HanGil Eye Hospital, Incheon 21388, Korea;
- Department of Ophthalmology, College of Medicine, Catholic Kwandong University, Incheon 21388, Korea
| | - Seok-Jae Lee
- Fight against Angiogenesis-Related Blindness (FARB) Laboratory, Clinical Research Institute, Seoul National University Hospital, Seoul 03080, Korea; (S.-J.L.); (J.-H.K.)
- Department of Biomedical Sciences, College of Medicine, Seoul National University, Seoul 03080, Korea
| | - Jeong-Hun Kim
- Fight against Angiogenesis-Related Blindness (FARB) Laboratory, Clinical Research Institute, Seoul National University Hospital, Seoul 03080, Korea; (S.-J.L.); (J.-H.K.)
- Department of Biomedical Sciences, College of Medicine, Seoul National University, Seoul 03080, Korea
- Department of Ophthalmology, College of Medicine, Seoul National University, Seoul 03080, Korea
- Advanced Biomedical Research Center, Korea Research Institute of Bioscience & Biotechnology, Daejeon 34141, Korea
| | - Sang-Mok Lee
- Department of Ophthalmology, HanGil Eye Hospital, Incheon 21388, Korea;
- Department of Ophthalmology, College of Medicine, Catholic Kwandong University, Incheon 21388, Korea
| |
Collapse
|
24
|
Chao C, Zhou S, Stapleton F, Chen S, Zhou X, Golebiowski B. The structural and functional corneal reinnervation mechanism at different regions after LASIK-an in vivo confocal microscopy study. Graefes Arch Clin Exp Ophthalmol 2021; 260:163-172. [PMID: 34453607 DOI: 10.1007/s00417-021-05381-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2021] [Revised: 07/27/2021] [Accepted: 08/09/2021] [Indexed: 11/25/2022] Open
Abstract
PURPOSE To determine the recovery of structural and functional corneal sensory nerves within the LASIK flap in order to provide insight to more proximal corneal reinnervation and symptoms post-LASIK. METHODS Twenty participants underwent femtosecond LASIK with a superior flap hinge. Ocular Comfort Index in Chinese (OCI-C), Cochet-Bonnet esthesiometry, and in vivo confocal microscopy were conducted before surgery and 1 week, 1-, 3-, and 6-months post-LASIK to measure symptoms, corneal sensitivity, nerve fiber density, width, and the number of interconnections within the flap (central and mid-temporal regions), and next to the superior flap hinge. Linear mixed models were used to compare differences between corneal regions at each time point post-LASIK and changes over time post-LASIK. Spearman's correlation tests were used to examine the associations between variables post-LASIK. RESULTS The least reduction in sensitivity (P < 0.03) and in nerve fiber density (P < 0.02) was found near the flap hinge compared to other regions, but no regional differences were found in nerve fiber width and interconnections. Nerve fiber density and the number of interconnections at all regions within the flap recovered over time (P < 0.02). The recovery of corneal sensitivity and nerve fiber width was only seen at the central and temporal regions (P < 0.04). No association was found between sensitivity and nerve parameters, but a higher OCI-C score was associated with a lower nerve fiber density near the hinge (r = - 0.43, P = 0.003) over time post-LASIK. CONCLUSION Corneal sensitivity and density are preserved in the hinge, but this preservation of the corneal nerve damage does not affect the nerve morphology.
Collapse
Affiliation(s)
- Cecilia Chao
- The School of Optometry and Vision Science, University of New South Wales, Sydney, Australia.
- University of Houston College of Optometry, 4901 Calhoun Rd., Houston, TX, 77204-2020, USA.
| | - S Zhou
- Wenzhou Medical University, Wenzhou, China
| | - F Stapleton
- The School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| | - S Chen
- Wenzhou Medical University, Wenzhou, China
| | - X Zhou
- Wenzhou Medical University, Wenzhou, China
| | - B Golebiowski
- The School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| |
Collapse
|
25
|
Chiang JCB, Goldstein D, Park SB, Krishnan AV, Markoulli M. Corneal nerve changes following treatment with neurotoxic anticancer drugs. Ocul Surf 2021; 21:221-237. [PMID: 34144206 DOI: 10.1016/j.jtos.2021.06.007] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2021] [Revised: 05/20/2021] [Accepted: 06/09/2021] [Indexed: 12/13/2022]
Abstract
Survival rates of cancer has improved with the development of anticancer drugs including systemic chemotherapeutic agents. However, long-lasting side effects could impact treated patients. Neurotoxic anticancer drugs are specific agents which cause chemotherapy-induced peripheral neuropathy (CIPN), a debilitating condition that severely deteriorates quality of life of cancer patients and survivors. The ocular surface is also prone to neurotoxicity but investigation into the effects of neurotoxic chemotherapy on the ocular surface has been more limited compared to other systemic etiologies such as diabetes. There is also no standardized protocol for CIPN diagnosis with an absence of a reliable, objective method of observing nerve damage structurally. As the cornea is the most densely innervated region of the body, researchers have started to focus on corneal neuropathic changes that are associated with neurotoxic chemotherapy treatment. In-vivo corneal confocal microscopy enables rapid and objective structural imaging of ocular surface microscopic structures such as corneal nerves, while esthesiometers provide means of functional assessment by examining corneal sensitivity. The current article explores the current guidelines and gaps in our knowledge of CIPN diagnosis and the potential role of in-vivo corneal confocal microscopy as a diagnostic or prognostic tool. Corneal neuropathic changes with neurotoxic anticancer drugs from animal research progressing through to human clinical studies are also discussed, with a focus on how these data inform our understanding of CIPN.
Collapse
Affiliation(s)
- Jeremy Chung Bo Chiang
- School of Optometry & Vision Science, Faculty of Medicine and Health, University of New South Wales, Sydney, Australia.
| | - David Goldstein
- Prince of Wales Clinical School, University of New South Wales, Sydney, Australia; Department of Medical Oncology, Prince of Wales Hospital, Sydney, Australia
| | - Susanna B Park
- Brain and Mind Centre, Faculty of Medicine and Health, University of Sydney, Sydney, Australia
| | - Arun V Krishnan
- Prince of Wales Clinical School, University of New South Wales, Sydney, Australia
| | - Maria Markoulli
- School of Optometry & Vision Science, Faculty of Medicine and Health, University of New South Wales, Sydney, Australia
| |
Collapse
|
26
|
CLEAR - Contact lens wettability, cleaning, disinfection and interactions with tears. Cont Lens Anterior Eye 2021; 44:157-191. [DOI: 10.1016/j.clae.2021.02.004] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Accepted: 02/01/2021] [Indexed: 12/15/2022]
|
27
|
CLEAR - Contact lens complications. Cont Lens Anterior Eye 2021; 44:330-367. [DOI: 10.1016/j.clae.2021.02.010] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2021] [Accepted: 02/01/2021] [Indexed: 12/20/2022]
|
28
|
Morgan PB, Murphy PJ, Gifford KL, Gifford P, Golebiowski B, Johnson L, Makrynioti D, Moezzi AM, Moody K, Navascues-Cornago M, Schweizer H, Swiderska K, Young G, Willcox M. CLEAR - Effect of contact lens materials and designs on the anatomy and physiology of the eye. Cont Lens Anterior Eye 2021; 44:192-219. [PMID: 33775377 DOI: 10.1016/j.clae.2021.02.006] [Citation(s) in RCA: 32] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Accepted: 02/01/2021] [Indexed: 12/19/2022]
Abstract
This paper outlines changes to the ocular surface caused by contact lenses and their degree of clinical significance. Substantial research and development to improve oxygen permeability of rigid and soft contact lenses has meant that in many countries the issues caused by hypoxia to the ocular surface have largely been negated. The ability of contact lenses to change the axial growth characteristics of the globe is being utilised to help reduce the myopia pandemic and several studies and meta-analyses have shown that wearing orthokeratology lenses or soft multifocal contact lenses can reduce axial length growth (and hence myopia). However, effects on blinking, ptosis, the function of Meibomian glands, fluorescein and lissamine green staining of the conjunctiva and cornea, production of lid-parallel conjunctival folds and lid wiper epitheliopathy have received less research attention. Contact lens wear produces a subclinical inflammatory response manifested by increases in the number of dendritiform cells in the conjunctiva, cornea and limbus. Papillary conjunctivitis is also a complication of all types of contact lenses. Changes to wear schedule (daily disposable from overnight wear) or lens materials (hydrogel from SiHy) can reduce papillary conjunctivitis, but the effect of such changes on dendritic cell migration needs further study. These changes may be associated with decreased comfort but confirmatory studies are needed. Contact lenses can affect the sensitivity of the ocular surface to mechanical stimulation, but whether these changes affect comfort requires further investigation. In conclusion, there have been changes to lens materials, design and wear schedules over the past 20+ years that have improved their safety and seen the development of lenses that can reduce the myopia development. However, several changes to the ocular surface still occur and warrant further research effort in order to optimise the lens wearing experience.
Collapse
Affiliation(s)
- Philip B Morgan
- Eurolens Research, Division of Pharmacy and Optometry, University of Manchester, UK.
| | - Paul J Murphy
- University of Waterloo, School of Optometry and Vision Science, Waterloo, Canada
| | - Kate L Gifford
- School of Optometry and Vision Science, Queensland University of Technology, Brisbane, Australia
| | - Paul Gifford
- School of Optometry and Vision Science, UNSW Sydney, Australia
| | | | - Leah Johnson
- CooperVision Specialty EyeCare, Gilbert, AZ, United States
| | - Dimitra Makrynioti
- School of Health Rehabilitation Sciences, University of Patras (Aigio), Greece
| | - Amir M Moezzi
- Centre for Ocular Research and Education, University of Waterloo, Canada
| | - Kurt Moody
- Johnson & Johnson Vision Care, Jacksonville, FL, United States
| | | | | | - Kasandra Swiderska
- Eurolens Research, Division of Pharmacy and Optometry, University of Manchester, UK
| | | | - Mark Willcox
- School of Optometry and Vision Science, UNSW Sydney, Australia
| |
Collapse
|
29
|
The Relationship between Corneal Nerve Morphology and Inflammatory Mediators and Neuropeptides in Healthy Individuals. Optom Vis Sci 2021; 97:145-153. [PMID: 32168236 DOI: 10.1097/opx.0000000000001484] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023] Open
Abstract
SIGNIFICANCE This study set out to explore the relationship between the ocular surface immune and nervous systems by exploring corneal nerve structure and the presence of inflammatory mediators and neuropeptides in the tear film. PURPOSE The purpose of this study was to determine the association between corneal nerve morphology and tear film inflammatory mediators and a neuropeptide in healthy individuals. METHODS Flush tears were collected from both eyes of 21 healthy participants aged 39.7 ± 9.9 years (10 females, 11 males) and analyzed for substance P, matrix metalloproteinase-9, tissue inhibitor of matrix metalloproteinase-1 (TIMP-1), tumor necrosis factor α, and interleukin 6. In vivo central corneal confocal microscopy was performed on the right eye, and eight images were captured. Variables measured were corneal nerve fiber length (CNFL), corneal nerve density (CNFD), corneal nerve branch density, fiber total branch density, corneal nerve fiber area, corneal nerve fiber width (CNFW), and corneal nerve fractal dimension (CNFrac). For each eye, the average across the images and the maximum and minimum values were determined for each variable. Pearson correlation analysis was performed to test for associations. RESULTS Substance P correlated with CNFrac (max) (r = -0.48, P = .03) and CNFW (min) (r = -0.52, P = .02). TIMP-1 correlated with CNFD (average) (r = -0.53, P = .03), CNFL (average) (r = -0.49, P = .05), CNFrac (max) (r = -0.49, P = .05), and CNFD (min) (r = -0.55, P = .02). Interleukin 6 correlated with CNFW (average) (r = -0.49, P = .05), the standard deviation of CNFL (r = -0.51, P = .04), CNFL (max) (r = -0.50, P = .04), CNFrac (max) (r = -0.50, P = .04), and CNFW (min) (r = -0.55, P = .02). Tumor necrosis factor α, matrix metalloproteinase-9, and its ratio with TIMP-1 did not correlate with any corneal nerve parameters. CONCLUSIONS Both inflammatory mediators and neuropeptides correlated with measures of corneal nerve morphology, supporting the link between the inflammatory and nervous systems.
Collapse
|
30
|
Therapeutic Hydrogel Lenses and the Antibacterial and Antibiotic Drugs Release. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app11041931] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The aim of this research was to evaluate the effects of different lens types on the availability and efficacy of anti-inflammatory and antibiotic drugs. Three lens types were examined: (1) nonionic hydrogel lenses; (2) ionic hydrogel lenses; and (3) silicone hydrogel lenses. The lenses were incubated with (a) dexamethasone; (b) betamethasone; (c) bromophenacyl bromide; and (d) chloramphenicol. Drug availability was quantified by gradient HPLC, and chloramphenicol antibacterial activity was quantified by testing the inhibition of Salmonella typhimurium growth on agar. The lens allowing the most abundant passage of betamethasone was the ionic hydrogel lens, followed by the silicone hydrogel lens and nonionic hydrogel lens. The lens allowing the most abundant passage of dexamethasone was the ionic hydrogel lens, but only at 0.5 h and 1 h. Regarding chloramphenicol, the ionic hydrogel lens and silicone hydrogel lens allowed more abundant passage than the nonionic hydrogel lens. These results highlight the relevance of adapting lenses to anti-inflammatory therapy, thus allowing a personalized medical approach.
Collapse
|
31
|
Ruiz-Lozano RE, Hernandez-Camarena JC, Loya-Garcia D, Merayo-Lloves J, Rodriguez-Garcia A. The molecular basis of neurotrophic keratopathy: Diagnostic and therapeutic implications. A review. Ocul Surf 2021; 19:224-240. [DOI: 10.1016/j.jtos.2020.09.007] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2020] [Revised: 09/13/2020] [Accepted: 09/22/2020] [Indexed: 12/11/2022]
|
32
|
Kamm K, Straube A, Ruscheweyh R. Baseline tear fluid CGRP is elevated in active cluster headache patients as long as they have not taken attack abortive medication. Cephalalgia 2020; 41:69-77. [PMID: 32847402 DOI: 10.1177/0333102420949858] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Calcitonin gene-related peptide plays a key role in cluster headache pathophysiology. It is released from the trigeminal nerve, which also innervates the eye. In this study, we tested if tear fluid calcitonin gene-related peptide measurement detects elevated calcitonin gene-related peptide levels in cluster headache patients compared to controls. METHODS Calcitonin gene-related peptide concentration in tear fluid and plasma of 16 active episodic and 11 chronic cluster headache patients (all outside acute attacks) and 60 controls were assessed using ELISA. RESULTS Cluster headache patients without use of attack abortive medication in the last 48 h showed significantly elevated tear fluid calcitonin gene-related peptide levels (1.78 ± 1.57 ng/ml, n = 17) compared to healthy controls (0.79 ± 0.74 ng/ml, p = 0.003) and compared to cluster headache patients who had used attack abortive medication in the last 48 h (0.84 ± 1.40 ng/ml, n = 10, p = 0.022). High calcitonin gene-related peptide levels in cluster headache patients were independent of the occurrence of a cluster headache attack in the last 48 hours (no attack: 1.95 ± 1.65 ng/ml, n = 8; attack: 1.63 ± 1.59 ng/ml, n = 9, p = 0.82) as long as no acute medication was used. No significant difference in tear fluid calcitonin gene-related peptide levels between episodic (1.48 ± 1.34 ng/ml) and chronic cluster headache patients (2.21 ± 1.88 ng/ml, p = 0.364) was detected. In contrast to these results in tear fluid, there were no significant group differences in plasma calcitonin gene-related peptide levels. CONCLUSION This study shows that active cluster headache patients have increased calcitonin gene-related peptide levels in tear fluid compared to healthy subjects, which are reduced to control levels after intake of attack abortive medication. Calcitonin gene-related peptide measurement in tear fluid is non-invasive, and has the advantage of allowing direct access to calcitonin gene-related peptide released from the trigeminal nerve.
Collapse
Affiliation(s)
- Katharina Kamm
- Department of Neurology, Ludwig-Maximilians-University Hospital, Munich, Germany
| | - Andreas Straube
- Department of Neurology, Ludwig-Maximilians-University Hospital, Munich, Germany
| | - Ruth Ruscheweyh
- Department of Neurology, Ludwig-Maximilians-University Hospital, Munich, Germany
| |
Collapse
|
33
|
Effects of Soft Toric, Rigid Gas-Permeable, and Mini-Scleral Lenses on Corneal Microstructure Using Confocal Microscopy. Eye Contact Lens 2020; 46:74-81. [DOI: 10.1097/icl.0000000000000612] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
34
|
González-García MJ, Murillo GM, Pinto-Fraga J, García N, Fernández I, Maldonado MJ, Calonge M, Enríquez-de-Salamanca A. Clinical and tear cytokine profiles after advanced surface ablation refractive surgery: A six-month follow-up. Exp Eye Res 2020; 193:107976. [PMID: 32081669 DOI: 10.1016/j.exer.2020.107976] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2019] [Revised: 02/07/2020] [Accepted: 02/14/2020] [Indexed: 12/14/2022]
Abstract
Neuropathic dry eye is one of the most frequently seen complications after corneal refractive surgery, however, its incidence decreases in a significant manner along the first six months postoperative, reaching between 10 and 45% incidence. However, little is known on the inflammatory status of the ocular surface during this recovery process. We aim to analyze the clinical and tear molecule concentration changes along six months after advanced surface ablation for myopia correction, in a prospective study including 18 eyes of 18 subjects who bilaterally underwent advanced surface ablation corneal refractive surgery. Clinical variables (uncorrected distance visual acuity, symptoms, conjunctival hyperemia, tear osmolarity, tear stability, corneal fluorescein staining, conjunctival lissamine staining, Schirmer test, and corneal esthesiometry) and a panel of 23 pro and anti-inflammatory cytokines/chemokines concentration in tears preoperatively and at 1, 3 and 6 months postoperatively were evaluated. We found that uncorrected distance visual acuity improved significantly from baseline at 1-month visit, symptoms improved and tear osmolarity decreased significantly from baseline at 3-month visit and there was a decrease in mechanical corneal threshold between 1-month and 3- and 6-month visits. Regarding tear molecules, IL-4, IL-5, IL-6, IL-13, IL-17A, and IFN-γ tear levels were significantly increased at all the three visits, compared to preoperative levels at V0; IL-2 and VEGF were also significantly increased at 1-month and 6-month visits, but not at 3-month visit, whereas IL-9 IL-10 and IL-12 were only significantly increased at 6-month visit. Although we found that there is a recovery in clinical variables at 6 months postoperatively (i.e. neuropathic dry eye was not developed in the sample), ocular surface homeostasis is not completely restored, as it can be seen by the changes in concentration of some pro and anti-inflammatory molecules measured in tears.
Collapse
Affiliation(s)
- María J González-García
- IOBA (Institute of Applied Ophthalmobiology), University of Valladolid, Campus Miguel Delibes, Paseo de Belén 17, 47011, Valladolid, Spain; CIBER-BBN (Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine), Valladolid, Spain.
| | - Giovanna M Murillo
- IOBA (Institute of Applied Ophthalmobiology), University of Valladolid, Campus Miguel Delibes, Paseo de Belén 17, 47011, Valladolid, Spain
| | - José Pinto-Fraga
- IOBA (Institute of Applied Ophthalmobiology), University of Valladolid, Campus Miguel Delibes, Paseo de Belén 17, 47011, Valladolid, Spain
| | - Noelia García
- IOBA (Institute of Applied Ophthalmobiology), University of Valladolid, Campus Miguel Delibes, Paseo de Belén 17, 47011, Valladolid, Spain
| | - Itziar Fernández
- IOBA (Institute of Applied Ophthalmobiology), University of Valladolid, Campus Miguel Delibes, Paseo de Belén 17, 47011, Valladolid, Spain; CIBER-BBN (Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine), Valladolid, Spain
| | - Miguel J Maldonado
- IOBA (Institute of Applied Ophthalmobiology), University of Valladolid, Campus Miguel Delibes, Paseo de Belén 17, 47011, Valladolid, Spain
| | - Margarita Calonge
- IOBA (Institute of Applied Ophthalmobiology), University of Valladolid, Campus Miguel Delibes, Paseo de Belén 17, 47011, Valladolid, Spain; CIBER-BBN (Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine), Valladolid, Spain
| | - Amalia Enríquez-de-Salamanca
- IOBA (Institute of Applied Ophthalmobiology), University of Valladolid, Campus Miguel Delibes, Paseo de Belén 17, 47011, Valladolid, Spain; CIBER-BBN (Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine), Valladolid, Spain
| |
Collapse
|
35
|
López-de la Rosa A, García-Vázquez C, Fernández I, Arroyo-Del Arroyo C, Enríquez-de-Salamanca A, González-García MJ. Substance P Level in Tears as a Potential Biomarker for Contact Lens Discomfort. Ocul Immunol Inflamm 2019; 29:43-56. [PMID: 31600092 DOI: 10.1080/09273948.2019.1668024] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Purpose: To analyze the effects of contact lens (CL) wear, time of the day, and CL discomfort (CLD) on clinical signs, tear inflammatory mediators and substance P.Methods: Thirty symptomatic and 30 asymptomatic CL wearers attended two visits (morning and afternoon) on two days (non-CL and CL wearing days). Comfort, meniscus area, noninvasive breakup time (NIBUT), tear collection, hyperemia, lid parallel conjunctival folds, fluorescein staining, and sensitivity were performed. The tear levels of 23 inflammatory mediators and substance P were measured.Results: Comfort, meniscus area, NIBUT, and MMP-9 were lower while conjunctival staining and EGF higher (p ≤ 0.015) on the CL wearing day. Comfort, IL-8/CXCL8, and VEGF were lower while EGF, IP-10/CXCL10, and MCP-1/CCL2 higher (p ≤ 0.047) in the afternoon. Comfort was lower and substance P higher (p ≤ 0.006) in symptomatic wearers.Conclusion: Substance P may be implicated in CLD etiology; its role and potential application as a biomarker should be further studied.
Collapse
Affiliation(s)
- Alberto López-de la Rosa
- Institute of Applied Ophthalmobiology (IOBA), University of Valladolid, Valladolid, Spain.,Department of Theoretical Physics, Atomic and Optics, University of Valladolid, Valladolid, Spain
| | - Carmen García-Vázquez
- Institute of Applied Ophthalmobiology (IOBA), University of Valladolid, Valladolid, Spain
| | - Itziar Fernández
- Institute of Applied Ophthalmobiology (IOBA), University of Valladolid, Valladolid, Spain.,Networking Research Center on Bioengineering Biomaterials and Nanomedicine (CIBER-BBN), Valladolid, Spain
| | - Cristina Arroyo-Del Arroyo
- Institute of Applied Ophthalmobiology (IOBA), University of Valladolid, Valladolid, Spain.,Department of Theoretical Physics, Atomic and Optics, University of Valladolid, Valladolid, Spain
| | - Amalia Enríquez-de-Salamanca
- Institute of Applied Ophthalmobiology (IOBA), University of Valladolid, Valladolid, Spain.,Networking Research Center on Bioengineering Biomaterials and Nanomedicine (CIBER-BBN), Valladolid, Spain
| | - María J González-García
- Institute of Applied Ophthalmobiology (IOBA), University of Valladolid, Valladolid, Spain.,Department of Theoretical Physics, Atomic and Optics, University of Valladolid, Valladolid, Spain.,Networking Research Center on Bioengineering Biomaterials and Nanomedicine (CIBER-BBN), Valladolid, Spain
| |
Collapse
|
36
|
Golebiowski B, Long J, Harrison K, Lee A, Chidi-Egboka N, Asper L. Smartphone Use and Effects on Tear Film, Blinking and Binocular Vision. Curr Eye Res 2019; 45:428-434. [DOI: 10.1080/02713683.2019.1663542] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Affiliation(s)
| | - Jennifer Long
- School of Optometry and Vision Science, UNSW Sydney, Australia
| | | | - Abigail Lee
- School of Optometry and Vision Science, UNSW Sydney, Australia
| | | | - Lisa Asper
- School of Optometry and Vision Science, UNSW Sydney, Australia
| |
Collapse
|
37
|
Topical Review: Effects of Contact Lens Wear on Corneal, Conjunctival, and Lid Margin Sensitivity. Optom Vis Sci 2019; 96:790-801. [DOI: 10.1097/opx.0000000000001429] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
38
|
Tummanapalli SS, Willcox MDP, Issar T, Kwai N, Poynten AM, Krishnan AV, Pisarcikova J, Markoulli M. The Effect of Age, Gender and Body Mass Index on Tear Film Neuromediators and Corneal Nerves. Curr Eye Res 2019; 45:411-418. [DOI: 10.1080/02713683.2019.1666998] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Affiliation(s)
| | - Mark D. P. Willcox
- School of Optometry & Vision Science, University of New South Wales, Sydney, Australia
| | - Tushar Issar
- Prince of Wales Clinical School, University of New South Wales, Sydney, Australia
| | - Natalie Kwai
- Prince of Wales Clinical School, University of New South Wales, Sydney, Australia
| | - Ann M. Poynten
- Department of Endocrinology, Prince of Wales Hospital, Sydney, Australia
| | - Arun V. Krishnan
- Prince of Wales Clinical School, University of New South Wales, Sydney, Australia
| | - Jana Pisarcikova
- School of Optometry & Vision Science, University of New South Wales, Sydney, Australia
| | - Maria Markoulli
- School of Optometry & Vision Science, University of New South Wales, Sydney, Australia
| |
Collapse
|
39
|
Sensory Adaptation to Silicone Hydrogel Contact Lens Wear Is Not Associated With Alterations in the Corneal Subbasal Nerve Plexus. Cornea 2019; 38:1142-1146. [PMID: 31232743 DOI: 10.1097/ico.0000000000002031] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
PURPOSE To evaluate corneal subbasal nerve alterations in contact lens (CL)-naive silicone hydrogel CL wearers and to investigate the relationship between structural subbasal nerve changes with corneal sensitivity. METHODS Twenty eyes of 20 neophyte daily silicone hydrogel CL wearers and 20 eyes of age-matched control subjects were recruited for this prospective longitudinal study. Corneal subbasal nerve densities were evaluated using in vivo confocal microscopy. Central corneal tactile sensitivity was measured using Cochet-Bonnet esthesiometers. In vivo confocal microscopy and Cochet-Bonnet esthesiometry were performed before and at the 6-month time point after the initiation of CL wear. Two-way repeated measures analysis of variance, χ, and Wilcoxon signed-rank tests were used for statistical analyses. RESULTS The mean ages of CL users and control subjects were 21.8 ± 1.8 years (range = 19-24 years) and 21.5 ± 2.3 years (range = 20-24 years), respectively (P = 0.579). Compared with their baseline values, there were no significant changes at the 6-month follow-up period in the mean total subbasal nerve fiber length (2266.6 ± 414.6 vs. 2277.9 ± 405.0 μm/frame; P = 0.432), mean total subbasal nerve branch density (10.4 ± 1.5 vs. 10.5 ± 1.3 nerves/frame; P = 0.655), or the mean long nerve fiber density (4.7 ± 0.7 vs. 4.8 ± 0.7 nerves/frame; P = 0.564) of CL users. Mechanical corneal sensitivity remained unaltered during the 6-month period in CL users (11.2 ± 0.5 vs. 11.2 ± 0.5; P = 1.000). No significant changes were observed in the subbasal nerve plexus or corneal tactile sensitivity of the control subjects during the study interval. CONCLUSIONS Sensory adaptation to CL wear is not mediated through attenuation of the subbasal nerve or reduction of corneal tactile sensitivity in CL-naive users.
Collapse
|
40
|
Murugesan V, Dwivedi R, Saini M, Gupta V, Dada T, Vivekanandhan S. Tear neuromediators in eyes on chronic topical antiglaucoma therapy with and without BAK preservatives. Br J Ophthalmol 2019; 105:141-148. [PMID: 31383648 DOI: 10.1136/bjophthalmol-2019-314234] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2019] [Revised: 06/18/2019] [Accepted: 07/19/2019] [Indexed: 11/03/2022]
Abstract
PURPOSE To evaluate tear neuropeptides (NPs) (vasoactive intestinal peptide (VIP), neuropeptide Y (NPY), calcitonin gene-related peptide (CGRP), substance P (SP), nerve growth factor (NGF)) in chronic ocular topical hypotensive therapy with and without benzalkonium chloride (BAK) preservative. METHODS A comparative, open label, cross-sectional study of patients using antiglaucoma medications for >6 months with BAK (group I), without BAK (group II) and controls was done. Tear NPs (ELISA), ocular surface evaluation tests (tear breakup time (TBUT), Schirmer's test, corneal and conjunctival staining score) and confocal central corneal subbasal nerve fibre layer (SBNFL) imaging was done. RESULTS Of 153 eyes evaluated, group 1 (82 eyes (41 patients; mean age 48±14.5 years)) and group 2 (71 eyes (36 patients; mean age 43.11±15 years)) were on therapy for a mean duration of 10.05±2.0 and 9.67±2.3 months, respectively. Tear analysis showed elevated SP and NGF (p<0.01); decreased CGRP (p=0.03), VIP and NPY (p<0.01) compared with controls (n=30, mean age 29.33±5.7 years). Tear NP levels (SP (p=0.1), NGF (p=0.33), CGRP (p=1), VIP (p=0.87), NPY (p=0.83)) and SBNFL (p=0.09) were comparable in both groups. There was no correlation seen between tear NP levels and clinical tests and SBNFL. CONCLUSION Our study analysis points towards altered tear NP levels in eyes on chronic topical hypotensive therapy in comparison with controls with no significant difference in tear NP levels and central corneal SBNFL density between the BAK preservative and BAK-free antiglaucoma therapy.
Collapse
Affiliation(s)
- Vanathi Murugesan
- Dr R P Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, Delhi, India
| | - Roopa Dwivedi
- Dr R P Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, Delhi, India
| | - Manu Saini
- Dr R P Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, Delhi, India
| | - Viney Gupta
- Dr R P Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, Delhi, India
| | - Tanuj Dada
- Dr R P Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, Delhi, India
| | - S Vivekanandhan
- Neurobiochemistry Lab, C N Centre, All India Institute of Medical Sciences, New Delhi, India
| |
Collapse
|
41
|
Kamm K, Straube A, Ruscheweyh R. Calcitonin gene-related peptide levels in tear fluid are elevated in migraine patients compared to healthy controls. Cephalalgia 2019; 39:1535-1543. [PMID: 31603037 DOI: 10.1177/0333102419856640] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Calcitonin gene-related peptide (CGRP) released from trigeminal nerve fibres indicates trigeminal activation and has a key role in migraine pathophysiology. The trigeminal nerve directly innervates the eye. Therefore, in this study, we compared Calcitonin gene-related peptide in tear fluid of migraine patients and healthy controls. METHODS Calcitonin gene-related peptide concentrations in tear fluid and plasma of 48 episodic and 45 chronic migraine patients and 48 controls were assessed using ELISA. RESULTS Calcitonin gene-related peptide levels in tear fluid (0.94 ± 1.11 ng/ml) were ∼140 times higher than plasma concentrations (6.81 ± 4.12 pg/ml). Tear fluid CGRP concentrations were elevated in interictal migraine patients (1.10 ± 1.27 ng/ml, n = 49) compared to controls (0.75 ± 0.80 ng/ml, p = 0.022). There was no difference in tear fluid CGRP levels between interictal episodic and chronic migraine patients (episodic: 1.09 ± 1.47 ng/ml, n = 30 and chronic: 1.10 ± 0.89 ng/ml, n = 19) and no correlation of tear fluid CGRP levels with headache frequency in interictal patients (rho = 0.062, p = 0.674). Unmedicated ictal migraine patients had even more elevated tear fluid CGRP levels than interictal migraine patients (1.92 ± 1.84 ng/ml, n = 13, p = 0.102), while medicated ictal migraine patients had lower levels (0.56 ± 0.47 ng/ml, n = 25, p = 0.011 compared to interictal patients), which were undistinguishable from controls (p = 0.609). In contrast to tear fluid, no significant group differences were found in plasma CGRP levels. CONCLUSION To the best of our knowledge, this study shows, for the first time, increased CGRP tear fluid levels in migraine patients compared to healthy subjects. Detection of calcitonin gene-related peptide in tear fluid is non-invasive, and likely allows a more direct access to CGRP released from the trigeminal nerve than plasma sampling.
Collapse
Affiliation(s)
- Katharina Kamm
- Department of Neurology, Ludwig-Maximilians-University Hospital, Munich, Germany
| | - Andreas Straube
- Department of Neurology, Ludwig-Maximilians-University Hospital, Munich, Germany
| | - Ruth Ruscheweyh
- Department of Neurology, Ludwig-Maximilians-University Hospital, Munich, Germany
| |
Collapse
|
42
|
Colorado LH, Markoulli M, Edwards K. The Relationship Between Corneal Dendritic Cells, Corneal Nerve Morphology and Tear Inflammatory Mediators and Neuropeptides in Healthy Individuals. Curr Eye Res 2019; 44:840-848. [PMID: 30909745 DOI: 10.1080/02713683.2019.1600196] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Purpose: To determine the association between corneal dendritic cell (DC) density and corneal nerve morphology and tear film inflammatory mediators and neuromediators in healthy individuals. Methods: Flush tears were collected from 21 healthy participants aged 39.7 ± 9.9 years and analyzed for total protein content (TPC), substance P, matrix-metalloproteinase-9 (MMP-9), tissue inhibitor of MMPs-1 (TIMP-1), tumor necrosis factor-a (TNF-α) and interleukin-6 (IL-6). In vivo confocal microscopy was used to assess DC density and corneal nerve morphology. Corneal nerve variables measured were corneal nerve fiber length (CNFL), fiber density (CNFD), branch density (CNBD), fiber total branch density (CTBD), fiber area (CNFA), fiber width (CNFW) and fractal dimension (CNFrac). Results: Participants with DC density over 50 cells/mm2 correlated with CNBD-average (r = 0.7, p = 0.02), CNBD-high (r = 0.6, p = 0.02), CNBD-low (r = 0.6, p = 0.02) CTBD-average (r = 0.7, p = 0.01), CTBD-high (r = 0.6, p = 0.03), CTBD-low (r = 0.7, p = 0.01), CNFA-average (r = 0.7, p = 0.00), CNFA-high (r = 0.7, p = 0.01), CNFA-low (r = 0.8, p < 0.001), CNFrac-SD (r = -0.6, p = 0.04), CNFrac-low (r = 0.6, p = 0.04) and CNFL-low (r = 0.7, p = 0.02). The percentage of MMP-9 correlated with DC density in the entire cohort (r = 0.47, p = 0.03). Conclusions: Corneal nerve measures showed a strong correlation with higher DC density, suggesting that the number of cells maybe be modulated by the corneal nerves in the central cornea. MMP-9 also showed a moderate correlation with DC, supporting an inflammatory role.
Collapse
Affiliation(s)
- Luisa H Colorado
- a Institute of Health and Biomedical Innovation, School of Optometry and Vision Science, Queensland University of Technology , Brisbane , Australia
| | - Maria Markoulli
- b School of Optometry & Vision Science, University of New South Wales , Sydney , Australia
| | - Katie Edwards
- a Institute of Health and Biomedical Innovation, School of Optometry and Vision Science, Queensland University of Technology , Brisbane , Australia
| |
Collapse
|
43
|
Review of Biomarkers in Ocular Matrices: Challenges and Opportunities. Pharm Res 2019; 36:40. [PMID: 30673862 PMCID: PMC6344398 DOI: 10.1007/s11095-019-2569-8] [Citation(s) in RCA: 90] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2018] [Accepted: 01/07/2019] [Indexed: 02/05/2023]
Abstract
Biomarkers provide a powerful and dynamic approach to improve our understanding of the mechanisms underlying ocular diseases with applications in diagnosis, disease modulation or for predicting and monitoring of clinical response to treatment. Defined as measurable indicator of normal or pathological processes, biomarker evaluation has been used extensively in drug development within clinical settings to better comprehend effectiveness of treatment in ocular diseases. Biomarkers in the eye have the advantage of access to multiple ocular matrices via minimally invasive methods. Repeat sampling for biomarker assessment has enabled reproducible objective measures of disease process or biological responses to a drug treatment. This review describes the usage of biomarkers with respect to four commonly sampled ocular matrices in clinic: tears, conjunctiva, aqueous humor and vitreous. Issues that affect the evaluation of biomarkers are discussed along with opportunities to leverage biomarkers such that ultimately, they can be used for customized targeted therapy.
Collapse
|
44
|
Bussan KA, Robertson DM. Contact lens wear and the diabetic corneal epithelium: A happy or disastrous marriage? J Diabetes Complications 2019; 33:75-83. [PMID: 30391097 PMCID: PMC7364814 DOI: 10.1016/j.jdiacomp.2018.09.015] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/25/2018] [Revised: 09/10/2018] [Accepted: 09/23/2018] [Indexed: 12/11/2022]
Abstract
Diabetes mellitus is an epidemic in the US and abroad. With the advent of new contact lens technology, the use of contact lenses as glucose sensors in lieu of the traditional finger stick is quickly becoming realized. This has the potential to rapidly expand the contact lens market into this growing patient population. The independent cellular and physiological effects of contact lens wear and diabetes on the corneal epithelium have been described. However, little evidence exists to date to support whether there is increased risk associated with contact lens wear in diabetes. The focus of this review is to discuss what is known about the cellular effects of contact lenses on the corneal epithelium, the pathophysiological changes in the corneal epithelium that occur in diabetes, and whether an increased risk for corneal epithelial damage and/or infection may negatively impact safety in diabetic contact lens wearers. Available data indicates that there are inherent risks associated with contact lens wear in diabetics. Importantly, eye care practitioners fitting contact lenses in the diabetic patient need to carefully consider the duration of disease, the level of glycemic control, the presence of retinopathy, and the patient's overall health.
Collapse
Affiliation(s)
- Katherine A Bussan
- The Department of Ophthalmology, The University of Texas Southwestern Medical Center, United States of America
| | - Danielle M Robertson
- The Department of Ophthalmology, The University of Texas Southwestern Medical Center, United States of America.
| |
Collapse
|
45
|
Effects of ambient humidity on the Cochet-Bonnet aesthesiometer. Eye (Lond) 2018; 32:1644-1651. [PMID: 29921953 DOI: 10.1038/s41433-018-0150-z] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2017] [Revised: 01/11/2018] [Accepted: 05/16/2018] [Indexed: 11/08/2022] Open
Abstract
PURPOSE The Cochet-Bonnet (COBO) aesthesiometer is the current standard in corneal sensitivity assessment. This study investigates the influence of ambient room humidity levels on the stimulus force exerted by the instrument. METHODS A COBO instrument (Luneau Opthalmologie) with 0.12 mm nominal nylon filament diameter was placed in an environment chamber (Electro-tech systems Inc. PA, USA) at 25 °C and relative humidity (%RH) set to either 20-80%, in 10% steps. After 12 h in the chamber at a chosen %RH level, the instrument was removed and exerted force measured by pressing the nylon filament onto the plate of an analytical microbalance (Mettler-Toledo AB265; precision ±0.0001 g) at a perpendicular angle, by a predetermined amount. Exerted force onto the microbalance was recorded in grams for a specified filament length. Procedure was repeated for filament lengths 10-60 mm, in 5 mm steps. The instrument was returned to the chamber and procedure repeated 5 times, before repeating at the next %RH setting (random order). Measurements at each filament lengths were compared using one-way ANOVA and post-hoc Tukey's range test. A p-value < 0.05 denoted statistical significance. RESULTS Significant differences in exerted force were observed with alteration in %RH levels for each filament length (all p < 0.001). Exerted force decreased significantly with an increase in %RH for all filament lengths, with the average force decreasing by 15% with each 10% rise in %RH. CONCLUSIONS This study confirms previous suggestions that the rigidity of the COBO nylon filament is affected by ambient room humidity levels, with implications on the stimulus force delivered by the instrument. A conversion table is provided for converting filament lengths to pressure for a range of relative humidity levels.
Collapse
|
46
|
Tong L, Teng LS. Review of Literature on Measurements of Non-invasive Break Up Times, Lipid Morphology and Tear Meniscal Height Using Commercially Available Hand-held Instruments. Curr Eye Res 2018; 43:567-575. [PMID: 29452004 DOI: 10.1080/02713683.2018.1437454] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
Purpose/aims: Dry eye is a common multi-factorial disease characterized by tearfilm dysfunction. Diagnosis of dry eye requires documentation of tear status with non-invasive tear break up times (NIBUT), tear meniscal height (TMH), and tearfilm lipid layer. These parameters objectively assess tear stability and indirectly, the functional impact of meibomian gland dysfunction. While it is obvious that portable instrumentation gives broader access than fixed instrumentation, its value would be limited if it is unreliable and its precision and accuracy substantially worse than fixed instruments. MATERIALS/METHODS Because of the lack of systematic reviews concerning the Tearscope, we performed a scoping review of the literature to determine 1. the ranges of the tear parameters as measured by the device, 2. relationship between these measurements and other clinical variables, 3. Information about intra or inter-observer agreement, and comparison with another technique, where available. RESULTS We found 22 reports related to NIBUT, 18 reports concerning tearfilm lipid morphology (LM) based on classification of interference patterns, and 8 reports on TMH. While publication of these reports indicates an acceptance of the reliability of portable instruments, we interrogated these studies further to evaluate the results obtained from portable devices and found that there was no equivalent measurements in fixed devices (LM) or measurements differ considerably from fixed devices (NIBUT). In the case of TMH, portable measurements were similar to those by traditional slit-lamp microscopy. There were relatively few studies on TMH measured using handheld devices, but it was found to be correlated to NIBUT but not the Schirmer test values. CONCLUSIONS Imaging algorithms in portable tearfilm instruments should be further standardized to facilitate wider adoption and evaluation. In the next few years, new emerging technologies will employ a strategy of non-invasive tear testing that is portable and relatively inexpensive, and these will enhance adoption of such tools in the clinic.
Collapse
Affiliation(s)
- Louis Tong
- a Singapore National Eye Centre , Singapore.,b Singapore Eye Research Institute , Singapore.,c Duke-NUS Medical School , Singapore.,d Yong Loo Lin School of Medicine , National University of Singapore , Singapore
| | | |
Collapse
|
47
|
Preinflammatory Signs in Established Reusable and Disposable Contact Lens Wearers. Optom Vis Sci 2017; 94:1003-1008. [DOI: 10.1097/opx.0000000000001129] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
|
48
|
Chao C, Richdale K, Jalbert I, Doung K, Gokhale M. Non-invasive objective and contemporary methods for measuring ocular surface inflammation in soft contact lens wearers - A review. Cont Lens Anterior Eye 2017; 40:273-282. [PMID: 28602547 DOI: 10.1016/j.clae.2017.05.008] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2016] [Revised: 05/25/2017] [Accepted: 05/29/2017] [Indexed: 10/19/2022]
Abstract
Contact lens wear is one of the primary risk factors for the development of ocular surface inflammatory events. The purpose of this review is to examine and summarize existing knowledge on the mechanisms of contact lens related ocular surface inflammation and the evidence for the effectiveness of current objective methods to measure ocular surface inflammation. Contact lens wear is postulated to trigger an inflammatory response on the ocular surface due to mechanical, chemical, hypoxic stress, or by the introduction of microbes and their toxins. Apart from the traditional signs of inflammation, such as swelling, oedema, redness and heat, on the ocular surface, other methods to measure ocular surface inflammation in sub-clinical levels include tear inflammatory mediator concentrations, conjunctival cell morphology, and corneal epithelial dendritic cell density and morphology. Tear inflammatory mediator concentrations are up- or down-regulated during contact lens wear, with or without the presence of associated inflammatory events. There is higher conjunctival cell metaplasia observed with contact lens wear, but changes in goblet cell density are inconclusive. Dendritic cell density is seen to increase soon after initiating soft contact lens wear. The long term effects of contact lens wear on dendritic cell migration in the cornea and conjunctiva, including the lid wiper area, require further investigation. Currently patient factors, such as age, smoking, systemic diseases and genetic profile are being studied. A better understanding of these mechanisms may facilitate the development of new management options and strategies to minimize ocular surface inflammation related to contact lens wear.
Collapse
Affiliation(s)
- Cecilia Chao
- College of Optometry, State University of New York, New York, USA; School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| | - Kathryn Richdale
- College of Optometry, State University of New York, New York, USA
| | - Isabelle Jalbert
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| | - Kim Doung
- College of Optometry, State University of New York, New York, USA
| | - Moneisha Gokhale
- Deakin Optometry, Deakin University, 75 Pigdons Road, Waurn Ponds, Victoria, 3216, Australia.
| |
Collapse
|
49
|
Lum E, Golebiowski B, Swarbrick HA. Changes in corneal subbasal nerve morphology and sensitivity during orthokeratology: Recovery of change. Ocul Surf 2017; 15:236-241. [DOI: 10.1016/j.jtos.2017.01.009] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2016] [Revised: 01/20/2017] [Accepted: 01/21/2017] [Indexed: 11/29/2022]
|