Chen WS, Abkar L, Mohseni M. Evaluating ATP testing for distribution system monitoring: comparison to HPC, impact of chlorine quenching, and hold time dependency. J Biol Eng 2024; 18:63. [PMID: 39501290 PMCID: PMC11536932 DOI: 10.1186/s13036-024-00446-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2024] [Accepted: 09/03/2024] [Indexed: 11/09/2024] Open
Abstract
Adenosine triphosphate (ATP) assays have a faster turnaround time and higher sensitivity than traditional cultivation methods for microbial monitoring. Challenges implementing ATP testing include incompatibility with chlorine quenching agents and hold time sensitivity, which are not well-studied. Chlorinated distribution system samples were collected from two Canadian utilities, Metro Vancouver (n = 40 samples) and Halifax Water (n = 283). No significant correlations were observed between heterotrophic cell count (HPC) and cellular ATP, suggesting these do not correlate well in waters with low biological activity (median HPC < 2 CFU/mL). However, interpretation of HPC and cATP results (based on the HPC guideline of 100 CFU/mL and cATP of 10 pg/mL) yielded the same conclusion for 95% of samples, suggesting a potential decision-making framework to replace HPC with cATP. Moreover, cATP correlates better with free chlorine (p < 0.04) compared with HPC for one of the studied systems. Importantly, adding chlorine quench (10% sodium thiosulfate) did not produce significantly different cATP results, nor did analyzing at various hold times of 4-, 6-, and 24-h. This study supports the integration of ATP testing into existing sampling procedures for water utilities, as a sensitive, fast, and reliable monitoring method.
Collapse
Affiliation(s)
- William S Chen
- Department of Chemical and Biological Engineering, University of British Columbia, 2360 East Mall, Vancouver, Canada
| | - Leili Abkar
- Department of Chemical and Biological Engineering, University of British Columbia, 2360 East Mall, Vancouver, Canada
| | - Madjid Mohseni
- Department of Chemical and Biological Engineering, University of British Columbia, 2360 East Mall, Vancouver, Canada.
| |
Collapse
|
2
|
van der Waals MJ, van Bel N, van Charante F, van Rijn J, van der Veen A, van der Wielen PWJJ. Alternative for HPC22 after repairs in the drinking water distribution system. WATER RESEARCH 2024; 265:122264. [PMID: 39173355 DOI: 10.1016/j.watres.2024.122264] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/04/2024] [Revised: 08/08/2024] [Accepted: 08/12/2024] [Indexed: 08/24/2024]
Abstract
There is a risk of contamination by (pathogenic) microorganisms from the outside environment into the drinking water during maintenance or pipe breaches in the drinking water distribution system (DWDS) and, consequently, the drinking water distributed to consumers may result in possible detrimental effects on public health. Traditional time-consuming microbiological testing is, therefore, performed to confirm drinking water is not microbially contaminated. This is done by culturing methods of the faecal indicators Escherichia coli, intestinal enterococci and the technical parameters coliform bacteria and heterotrophic plate counts at 22 °C (HPC22). In this study, fast methods (adenosine triphosphate (ATP), flow cytometry, enzyme activity and qPCR) were compared as an alternative for HPC22. Using dilution series and field samples, ATP (ATPtotal-lab and ATPcell-mob) and enzymatic activity (ALP-2) methods proved to be the more reliable and sensitive than flow cytometry and qPCR methods for detecting microbiological contaminations in drinking water. Significant (p < 0.05) and relatively strong correlations (R2 = 0.61-0.76) were obtained between HPC22 and both ATP methods, enzyme activity and qPCR parameters, but relations with flow cytometry were weak (R2 = 0.24 - 0.52). The samples taken after repairs or a calamity from the DWDS showed in general limited variation in the HPC22 count and were in most cases below the guidance level of 1,000 CFU/mL. We recommend that the best performing alternative methods, i.e. ATPtotal-lab and ATPcell-mob and ALP-2, should be included next to HPC22 in additional field studies to further test and compare these methods to be able to decide which fast method can replace HPC22 analysis after maintenance work in the DWDS.
Collapse
Affiliation(s)
| | - Nikki van Bel
- KWR Water Research Institute, Groningenhaven 7, Nieuwegein, 3433 PE, the Netherlands.
| | - Frits van Charante
- KWR Water Research Institute, Groningenhaven 7, Nieuwegein, 3433 PE, the Netherlands
| | - Jeroen van Rijn
- KWR Water Research Institute, Groningenhaven 7, Nieuwegein, 3433 PE, the Netherlands
| | - Anita van der Veen
- KWR Water Research Institute, Groningenhaven 7, Nieuwegein, 3433 PE, the Netherlands
| | | |
Collapse
|
3
|
Rosenqvist T, Chan S, Ahlinder J, Salomonsson EN, Suarez C, Persson KM, Rådström P, Paul CJ. Inoculation with adapted bacterial communities promotes development of full scale slow sand filters for drinking water production. WATER RESEARCH 2024; 253:121203. [PMID: 38402751 DOI: 10.1016/j.watres.2024.121203] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Revised: 01/11/2024] [Accepted: 01/24/2024] [Indexed: 02/27/2024]
Abstract
Gravity-driven filtration through slow sand filters (SSFs) is one of the oldest methods for producing drinking water. As water passes through a sand bed, undesired microorganisms and chemicals are removed by interactions with SSF biofilm and its resident microbes. Despite their importance, the processes through which these microbial communities form are largely unknown, as are the factors affecting these processes. In this study, two SSFs constructed using different sand sources were compared to an established filter and observed throughout their maturation process. One SSF was inoculated through addition of sand scraped from established filters, while the other was not inoculated. The operational and developing microbial communities of SSFs, as well as their influents and effluents, were studied by sequencing of 16S ribosomal rRNA genes. A functional microbial community resembling that of the established SSF was achieved in the inoculated SSF, but not in the non-inoculated SSF. Notably, the non-inoculated SSF had significantly (p < 0.01) higher abundances of classes Armatimonadia, Elusimicrobia, Fimbriimonadia, OM190 (phylum Planctomycetota), Parcubacteria, Vampirivibrionia and Verrucomicrobiae. Conversely, it had lower abundances of classes Anaerolineae, Bacilli, bacteriap25 (phylum Myxococcota), Blastocatellia, Entotheonellia, Gemmatimonadetes, lineage 11b (phylum Elusimicrobiota), Nitrospiria, Phycisphaerae, subgroup 22 (phylum Acidobacteriota) and subgroup 11 (phylum Acidobacteriota). Poor performance of neutral models showed that the assembly and dispersal of SSF microbial communities was mainly driven by selection. The temporal turnover of microbial species, as estimated through the scaling exponent of the species-time relationship, was twice as high in the non-inoculated filter (0.946 ± 0.164) compared to the inoculated filter (0.422 ± 0.0431). This study shows that the addition of an inoculum changed the assembly processes within SSFs. Specifically, the rate at which new microorganisms were observed in the biofilm was reduced. The reduced temporal turnover may be driven by inoculating taxa inhibiting growth, potentially via secondary metabolite production. This in turn would allow the inoculation community to persist and contribute to SSF function.
Collapse
Affiliation(s)
- Tage Rosenqvist
- Division of Applied Microbiology, Department of Chemistry, Lund University, P.O. Box 124, SE-221 00 Lund, Sweden; Sweden Water Research AB, Ideon Science Park, Scheelevägen 15, SE-223 70 Lund, Sweden
| | - Sandy Chan
- Division of Applied Microbiology, Department of Chemistry, Lund University, P.O. Box 124, SE-221 00 Lund, Sweden; Sweden Water Research AB, Ideon Science Park, Scheelevägen 15, SE-223 70 Lund, Sweden; Sydvatten AB, Hyllie Stationstorg 21, SE-215 32 Malmö, Sweden
| | - Jon Ahlinder
- FOI, Swedish Defense Research Agency, Cementvägen 20, SE-906 21 Umeå, Sweden
| | | | - Carolina Suarez
- Water Resources Engineering, Department of Building and Environmental Technology, Lund University, SE-221 00 Lund, Sweden
| | - Kenneth M Persson
- Sydvatten AB, Hyllie Stationstorg 21, SE-215 32 Malmö, Sweden; Water Resources Engineering, Department of Building and Environmental Technology, Lund University, SE-221 00 Lund, Sweden
| | - Peter Rådström
- Division of Applied Microbiology, Department of Chemistry, Lund University, P.O. Box 124, SE-221 00 Lund, Sweden
| | - Catherine J Paul
- Division of Applied Microbiology, Department of Chemistry, Lund University, P.O. Box 124, SE-221 00 Lund, Sweden; Water Resources Engineering, Department of Building and Environmental Technology, Lund University, SE-221 00 Lund, Sweden.
| |
Collapse
|
4
|
Claveau L, Hudson N, Jeffrey P, Hassard F. To gate or not to gate: Revisiting drinking water microbial assessment through flow cytometry fingerprinting. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 912:169138. [PMID: 38070556 DOI: 10.1016/j.scitotenv.2023.169138] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Revised: 11/20/2023] [Accepted: 12/04/2023] [Indexed: 01/18/2024]
Abstract
Flow cytometry has been utilized for over a decade as a rapid and reproducible approach to assessing microbial quality of drinking water. However, the need for specialized expertise in gating-a fundamental strategy for distinguishing cell populations-introduces the potential for human error and obstructs the standardization of methods. This work conducts a comprehensive analysis of various gating approaches applied to flow cytometric scatter plots, using a dataset spanning a year. A sensitivity analysis is carried out to examine the impact of different gating strategies on final cell count results. The findings show that dynamic gating, which requires user intervention, is essential for the analysis of highly variable raw waters and distributed water. In contrast, static gating proved suitable for more stable water sources, interstage sample locations, and water presenting a particularly low cell count. Our conclusions suggest that cell count analysis should be supplemented with fluorescence fingerprinting to gain a more complete understanding of the variability in microbial populations within drinking water supplies. Establishing dynamic baselines for each water type in FCM monitoring studies is essential for choosing the correct gating strategy. FCM fingerprinting offers a dynamic approach to quantify treatment processes, enabling options for much better monitoring and control. This study offers new insights into the vagaries of various flow cytometry gating strategies, thereby substantially contributing to best practices in the water industry. The findings foster more efficient and reliable water analysis, improving of standardizing methods in microbial water quality assessment using FCM.
Collapse
Affiliation(s)
- L Claveau
- Cranfield University, College Road, Cranfield, Bedfordshire MK43 0AL, UK
| | - N Hudson
- South East Water, Rocfort Road, Snodland, Kent ME6 5AH, UK
| | - P Jeffrey
- Cranfield University, College Road, Cranfield, Bedfordshire MK43 0AL, UK
| | - F Hassard
- Cranfield University, College Road, Cranfield, Bedfordshire MK43 0AL, UK.
| |
Collapse
|
5
|
Park JW, Boxall J, Maeng SK. Predicting heterotrophic plate count exceedance in tap water: A binary classification model supervised by culture-independent data. WATER RESEARCH 2023; 242:120172. [PMID: 37307683 DOI: 10.1016/j.watres.2023.120172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Revised: 06/01/2023] [Accepted: 06/02/2023] [Indexed: 06/14/2023]
Abstract
Culture-independent data can be utilized to identify heterotrophic plate count (HPC) exceedances in drinking water. Although HPC represents less than 1% of the bacterial community and exhibits time lags of several days, HPC data are widely used to assess the microbiological quality of drinking water and are incorporated into drinking water standards. The present study confirmed the nonlinear relationships between HPC, intact cell count (ICC), and adenosine triphosphate (ATP) in tap water samples (stagnant and flushed). By using a combination of ICC, ATP, and free chlorine data as inputs, we show that HPC exceedance can be classified using a 2-layer feed-forward artificial neural network (ANN). Despite the nonlinearity of HPC, the best binary classification model showed accuracies of 95%, sensitivity of 91%, and specificity of 96%. ICC and chlorine concentrations were the most important features for classifiers. The main limitations, such as sample size and class imbalance, were also discussed. The present model provides the ability to convert data from emerging measurement techniques into established and well-understood measures, overcoming culture dependence and offering near real-time data to help ensure the biostability and safety of drinking water.
Collapse
Affiliation(s)
- Ji Won Park
- Department of Civil and Environmental Engineering, Sejong University, 209 Neungdong-ro, Gwangjin-gu, Seoul 05006, Republic of Korea
| | - Joby Boxall
- Department of Civil and Structural Engineering, University of Sheffield, S13JD, United Kingdom
| | - Sung Kyu Maeng
- Department of Civil and Environmental Engineering, Sejong University, 209 Neungdong-ro, Gwangjin-gu, Seoul 05006, Republic of Korea.
| |
Collapse
|
6
|
Liu X, Pollner B, Paulitsch-Fuchs AH, Fuchs EC, Dyer NP, Loiskandl W, Lass-Flörl C. Investigation of the effect of sustainable magnetic treatment on the microbiological communities in drinking water. ENVIRONMENTAL RESEARCH 2022; 213:113638. [PMID: 35705130 DOI: 10.1016/j.envres.2022.113638] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/13/2022] [Accepted: 06/05/2022] [Indexed: 06/15/2023]
Abstract
The drinking water scarcity is posing a threat to mankind, hence better water quality management methods are required. Magnetic water treatment, which has been reported to improve aesthetic water quality and reduce scaling problems, can be an important addition to the traditional disinfectant dependent treatment. Despite the extensive market application opportunities, the effect of magnetic fields on (microbial) drinking water communities and subsequently the biostability is still largely unexplored, although the first patent was registered already 1945. Here flow cytometry was applied to assess the effect of weak magnetic fields (≤10 G) with strong gradients (≈800 G/m) on drinking water microbial communities. Drinking water was collected from the tap and placed inside the magnetic field (treated) and 5 m away from the magnet to avoid any background interferences (control) using both a static set-up and a shaking set-up. Samples were collected during a seven-day period for flow cytometry examination. Additionally, the effects of magnetic fields on the growth of Pseudomonas aeruginosa in autoclaved tap water were examined. Based on the fluorescent intensity of the stained nucleic acid content, the microbial cells were grouped into low nucleic acid content (LNA) and high nucleic acid content (HNA). Our results show that the LNA was dominant under nutrient limited condition while the HNA dominates when nutrient is more available. Such behavior of LNA and HNA matches well with the long discussed r/K selection model where r-strategists adapted to eutrophic conditions and K-strategists adapted to oligotrophic conditions. The applied magnetic fields selectively promote the growth of LNA under nutrient rich environment, which indicates a beneficial effect on biostability enhancement. Inhibition on an HNA representative Pseudomonas aeruginosa has also been observed. Based on our laboratory observations, we conclude that magnetic field treatment can be a sustainable method for microbial community management with great potential.
Collapse
Affiliation(s)
- Xiaoxia Liu
- Wetsus, European Centre of Excellence for Sustainable Water Technology, Oostergoweg 9, 8911 MA Leeuwarden, the Netherlands; Institute of Soil Physics and Rural Water Management, University of Natural Resources and Life Sciences, Vienna, Austria
| | - Bernhard Pollner
- Division of Hygiene and Medical Microbiology, Medical University of Innsbruck, Innsbruck, Austria
| | - Astrid H Paulitsch-Fuchs
- Diagnostic and Research Institute of Hygiene, Microbiology and Environmental Medicine, Medical University of Graz, Neue Stiftingtalstraße 2, 8010, Graz, Austria; Carinthia University of Applied Sciences, Biomedical Science, St. Veiterstraße 47, 9020 Klagenfurt, Austria
| | - Elmar C Fuchs
- Wetsus, European Centre of Excellence for Sustainable Water Technology, Oostergoweg 9, 8911 MA Leeuwarden, the Netherlands; Optical Sciences Group, Faculty of Science and Technology (TNW), University of Twente, Drienerlolaan 5, 7522NB Enschede, the Netherlands.
| | - Nigel P Dyer
- Wetsus, European Centre of Excellence for Sustainable Water Technology, Oostergoweg 9, 8911 MA Leeuwarden, the Netherlands; Coherent Water Systems, 2 Crich Avenue, DE23 6ES Derby, United Kingdom
| | - Willibald Loiskandl
- Institute of Soil Physics and Rural Water Management, University of Natural Resources and Life Sciences, Vienna, Austria
| | - Cornelia Lass-Flörl
- Division of Hygiene and Medical Microbiology, Medical University of Innsbruck, Innsbruck, Austria
| |
Collapse
|
7
|
Hegarty B, Dai Z, Raskin L, Pinto A, Wigginton K, Duhaime M. A snapshot of the global drinking water virome: Diversity and metabolic potential vary with residual disinfectant use. WATER RESEARCH 2022; 218:118484. [PMID: 35504157 DOI: 10.1016/j.watres.2022.118484] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/25/2022] [Revised: 04/01/2022] [Accepted: 04/19/2022] [Indexed: 05/22/2023]
Abstract
Viruses are important drivers of microbial community ecology and evolution, influencing microbial mortality, metabolism, and horizontal gene transfer. However, the effects of viruses remain largely unknown in many environments, including in drinking water systems. Drinking water metagenomic studies have offered a whole community perspective of bacterial impacts on water quality, but have not yet considered the influences of viruses. In this study, we address this gap by mining viral DNA sequences from publicly available drinking water metagenomes from distribution systems in six countries around the world. These datasets provide a snapshot of the taxonomic diversity and metabolic potential of the global drinking water virome; and provide an opportunity to investigate the effects of geography, climate, and drinking water treatment practices on viral diversity. Both environmental conditions and differences in sample processing were found to influence the viral composition. Using free chlorine as the residual disinfectant was associated with clear differences in viral taxonomic diversity and metabolic potential, with significantly fewer viral populations and less even viral community structures than observed in distribution systems without residual disinfectant. Additionally, drinking water viruses carry antibiotic resistance genes (ARGs), as well as genes to survive oxidative stress and nitrogen limitation. Through this study, we have demonstrated that viral communities are diverse across drinking water systems and vary with the use of residual disinfectant. Our findings offer directions for future research to develop a more robust understanding of how virus-bacteria interactions in drinking water distribution systems affect water quality.
Collapse
Affiliation(s)
- Bridget Hegarty
- Department of Civil and Environmental Engineering, Environmental and Water Resources Engineering Building, University of Michigan, 1351 Beal Ave. 181, Ann Arbor, MI 48109-2125, USA
| | - Zihan Dai
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing 100049, China
| | - Lutgarde Raskin
- Department of Civil and Environmental Engineering, Environmental and Water Resources Engineering Building, University of Michigan, 1351 Beal Ave. 181, Ann Arbor, MI 48109-2125, USA
| | - Ameet Pinto
- School of Civil and Environmental Engineering, Georgia Institute of Technology, Georgia
| | - Krista Wigginton
- Department of Civil and Environmental Engineering, Environmental and Water Resources Engineering Building, University of Michigan, 1351 Beal Ave. 181, Ann Arbor, MI 48109-2125, USA.
| | - Melissa Duhaime
- Department of Ecology and Evolutionary Biology, University of Michigan, 1105N University Ave., 4068 Biological Sciences Building, Ann Arbor, MI 48109-1085, USA.
| |
Collapse
|
8
|
Chen WT, Chien CC, Ho WS, Ou JH, Chen SC, Kao CM. Effects of treatment processes on AOC removal and changes of bacterial diversity in a water treatment plant. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2022; 311:114853. [PMID: 35276566 DOI: 10.1016/j.jenvman.2022.114853] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2021] [Revised: 02/27/2022] [Accepted: 03/04/2022] [Indexed: 06/14/2023]
Abstract
The effectiveness of different treatment processes on assimilable organic carbon (AOC) removal and bacterial diversity variations was evaluated in a water treatment plant. The van der Kooij technique was applied for AOC analysis and responses of bacterial communities were characterized by the metagenomics assay. Results show that the AOC concentrations were about 93, 148, 43, 51, 37, and 38 μg acetate-C/L in effluents of raw water basin, preozonation, rapid sand filtration (RSF), ozonation, biofiltration [biological activated carbon (BAC) filtration], and chlorination (clear water), respectively. Increased AOC concentrations were observed after preozonation, ozonation, and chlorination units due to the production of biodegradable organic matters after the oxidation processes. Results indicate that the oxidation processes were the main causes of AOC formation, which resulted in significant increases in AOC concentrations (18-59% increment). The AOC removal efficiencies were 47, 28, and 60% in the RSF, biofiltration, and the whole system, respectively. RSF and biofiltration were responsible for the AOC treatment and both processes played key roles in AOC removal. Thus, both RSF and biofiltration processes would contribute to AOC treatment after oxidation. Sediments from the raw water basin and filter samples from RSF and BAC units were collected and analyzed for bacterial communities. Results from scanning electron microscope analysis indicate that bacterial colonization was observed in filter materials. This indicates that the surfaces of the filter materials were beneficial to bacterial growth and AOC removal via the adsorption and biodegradation mechanisms. Next generation sequencing analyses demonstrate that water treatment processes resulted in the changes of bacterial diversity and community profiles in filters of RSF and BAC. According to the findings of bacterial composition and interactions, the dominant bacterial phyla were Proteobacteria (41% in RSF and 56% in BAC) followed by Planctomycetes and Acidobacteria in RSF and BAC systems, which might affect the AOC biodegradation efficiency. Results would be useful in developing AOC treatment and management processes in water treatment plants.
Collapse
Affiliation(s)
- W T Chen
- Institute of Environmental Engineering, National Sun Yat-Sen University, Kaohsiung, Taiwan
| | - C C Chien
- Graduate School of Biotechnology and Bioengineering, Yuan Ze University, Chung-Li City, Taoyuan, Taiwan
| | - W S Ho
- Institute of Environmental Engineering, National Sun Yat-Sen University, Kaohsiung, Taiwan
| | - J H Ou
- Institute of Environmental Engineering, National Sun Yat-Sen University, Kaohsiung, Taiwan
| | - S C Chen
- Department of Life Sciences, National Central University, Taoyuan, Taiwan.
| | - C M Kao
- Institute of Environmental Engineering, National Sun Yat-Sen University, Kaohsiung, Taiwan.
| |
Collapse
|
9
|
Zand E, Froehling A, Schoenher C, Zunabovic-Pichler M, Schlueter O, Jaeger H. Potential of Flow Cytometric Approaches for Rapid Microbial Detection and Characterization in the Food Industry-A Review. Foods 2021; 10:3112. [PMID: 34945663 PMCID: PMC8701031 DOI: 10.3390/foods10123112] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2021] [Revised: 11/14/2021] [Accepted: 11/16/2021] [Indexed: 12/11/2022] Open
Abstract
As microbial contamination is persistent within the food and bioindustries and foodborne infections are still a significant cause of death, the detection, monitoring, and characterization of pathogens and spoilage microorganisms are of great importance. However, the current methods do not meet all relevant criteria. They either show (i) inadequate sensitivity, rapidity, and effectiveness; (ii) a high workload and time requirement; or (iii) difficulties in differentiating between viable and non-viable cells. Flow cytometry (FCM) represents an approach to overcome such limitations. Thus, this comprehensive literature review focuses on the potential of FCM and fluorescence in situ hybridization (FISH) for food and bioindustry applications. First, the principles of FCM and FISH and basic staining methods are discussed, and critical areas for microbial contamination, including abiotic and biotic surfaces, water, and air, are characterized. State-of-the-art non-specific FCM and specific FISH approaches are described, and their limitations are highlighted. One such limitation is the use of toxic and mutagenic fluorochromes and probes. Alternative staining and hybridization approaches are presented, along with other strategies to overcome the current challenges. Further research needs are outlined in order to make FCM and FISH even more suitable monitoring and detection tools for food quality and safety and environmental and clinical approaches.
Collapse
Affiliation(s)
- Elena Zand
- Department of Food Science and Technology, Institute of Food Technology, University of Natural Resources and Life Sciences Vienna (BOKU), 1190 Vienna, Austria;
| | - Antje Froehling
- Leibniz Institute for Agricultural Engineering and Bioeconomy, Quality and Safety of Food and Feed, 14469 Potsdam, Germany; (A.F.); (O.S.)
| | - Christoph Schoenher
- Institute of Sanitary Engineering and Water Pollution Control, University of Natural Resources and Life Sciences, 1190 Vienna, Austria; (C.S.); (M.Z.-P.)
| | - Marija Zunabovic-Pichler
- Institute of Sanitary Engineering and Water Pollution Control, University of Natural Resources and Life Sciences, 1190 Vienna, Austria; (C.S.); (M.Z.-P.)
| | - Oliver Schlueter
- Leibniz Institute for Agricultural Engineering and Bioeconomy, Quality and Safety of Food and Feed, 14469 Potsdam, Germany; (A.F.); (O.S.)
| | - Henry Jaeger
- Department of Food Science and Technology, Institute of Food Technology, University of Natural Resources and Life Sciences Vienna (BOKU), 1190 Vienna, Austria;
| |
Collapse
|
10
|
Lin H, Wang Q, Zhou J, Wang D, Men Y, Bai Y, Qu J. Recovery trajectories and community resilience of biofilms in receiving rivers after wastewater treatment plant upgrade. ENVIRONMENTAL RESEARCH 2021; 199:111349. [PMID: 34019892 DOI: 10.1016/j.envres.2021.111349] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/08/2021] [Revised: 05/12/2021] [Accepted: 05/13/2021] [Indexed: 06/12/2023]
Abstract
Wastewater treatment plant (WWTP) upgrades can reduce both nutrient and micropollutant emissions into receiving rivers, thus modifying the composition and function of biological communities. However, how microbial communities vary and whether they can be restored to levels found in less-polluted rivers remains uncertain. Aquatic biofilms are sensitive to environmental change and respond rapidly to bottom-up pressure. Thus, we used 12 flumes configured in three experimental treatments to mimic the dynamic processes of biofilm microbial communities occurring in a wastewater-receiving river following WWTP upgrade, with rivers containing two levels of nutrients and micropollutants used as references. We compared the biofilm microbial biomass, carbon source utilization, and community composition among the three "blocks". Results showed that the metabolic patterns of the carbon sources and composition of the biofilm bacterial communities in the flumes mimicking a receiving river with WWTP upgrade recovered over time to those mimicking a less-disturbed river. The restoration of potential carboxylic acid-consuming denitrifying bacteria (i.e., Zoogloea, Comamonas, Dechloromonas, and Acinetobacter) likely played a significant role in this process. Combining quantitative analysis of the denitrification genes nirS and nosZ, we confirmed that the denitrification function of the river biofilms recovered after WWTP upgrade, consistent with our previous field investigation.
Collapse
Affiliation(s)
- Hui Lin
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China; University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Qiaojuan Wang
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China; University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Jie Zhou
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China; University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Donglin Wang
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China; University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Yujie Men
- Department of Chemical and Environmental Engineering, University of California, Riverside, CA, 92521, United States
| | - Yaohui Bai
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China.
| | - Jiuhui Qu
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China
| |
Collapse
|
11
|
Inkinen J, Siponen S, Jayaprakash B, Tiwari A, Hokajärvi AM, Pursiainen A, Ikonen J, Kauppinen A, Miettinen IT, Paananen J, Torvinen E, Kolehmainen M, Pitkänen T. Diverse and active archaea communities occur in non-disinfected drinking water systems-Less activity revealed in disinfected and hot water systems. WATER RESEARCH X 2021; 12:100101. [PMID: 34027378 PMCID: PMC8131914 DOI: 10.1016/j.wroa.2021.100101] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/21/2020] [Revised: 04/20/2021] [Accepted: 04/22/2021] [Indexed: 05/25/2023]
Abstract
The knowledge about the members of active archaea communities in DWDS is limited. The current understanding is based on high-throughput 16S ribosomal RNA gene (DNA-based) amplicon sequencing that reveals the diversity of active, dormant, and dead members of the prokaryote (bacteria, archaea) communities. The sequencing primers optimized for bacteria community analysis may underestimate the share of the archaea community. This study characterized archaea communities at five full-scale drinking water distribution systems (DWDS), representing a variety of drinking water production units (A-E); A&B use artificially recharged non-disinfected groundwater (ARG), the other DWDS's supplied water disinfected by using ultraviolet (UV) light and chlorine compounds, C&D were surface waterworks and E was a ground waterworks. For the first time for archaea community analyses, this study employed the archaea-specific high-throughput sequencing primers for 16S ribosomal RNA (rRNA) as a target (reverse-transcribed cDNA; an RNA-based approach) in addition to the previously used 16S rRNA gene target (rDNA; a DNA-based approach) to reveal the active fraction of the archaea present in DWDS. The archaea community structure in varying environmental conditions in the water and biofilm of the five DWDSs were investigated by taking into consideration the system properties (cold or hot water system) and water age (distance from the treatment plants) in samples from each season of one year. The RNA-based archaea amplicon reads were obtained mostly from cold water samples from DWDSs (A-B) distributing water without disinfection where the DNA-based and RNA-based analysis created separate clusters in a weighted beta-diversity analysis. The season and location in DWDS A further affected the diversity of these archaea communities as was seen by different clusters in beta-diversity plots. The recovery of archaea reads was not adequate for analysis in any of the disinfected samples in DWDSs C-E or non-disinfected hot water in DWDSs A-B when utilizing RNA-based template. The metabolically active archaea community of DWDSs thus seemed to be effectively controlled by disinfection of water and in the hot water systems by the temperature. All biofilms regardless of DWDS showed lower species richness values (mainly Nitrososphaeria class) than non-disinfected water from DWDSs A-B where several archaea classes occurred (e.g. Woesearchaeia, Nitrososphaeria, Micrarchaeia, Methanomicrobia, Iairchaeia, Bathyarchaeia) indicating only part of the archaea members were able to survive in biofilms. Thus, Archaea has been shown as a significant part of normal DWDS biota, and their role especially in non-disinfected DWDS may be more important than previously considered.
Collapse
Affiliation(s)
- Jenni Inkinen
- Finnish Institute for Health and Welfare, Department of Health Security, P.O. Box 95, FI-70701 Kuopio, Finland
- University of Eastern Finland, Institute of Biomedicine, P.O. Box 1627, FI-70211 Kuopio, Finland
| | - Sallamaari Siponen
- Finnish Institute for Health and Welfare, Department of Health Security, P.O. Box 95, FI-70701 Kuopio, Finland
- University of Eastern Finland, Department of Environmental and Biological Sciences, P.O. Box, 1627, FI-70211 Kuopio, Finland
| | | | - Ananda Tiwari
- Finnish Institute for Health and Welfare, Department of Health Security, P.O. Box 95, FI-70701 Kuopio, Finland
| | - Anna-Maria Hokajärvi
- Finnish Institute for Health and Welfare, Department of Health Security, P.O. Box 95, FI-70701 Kuopio, Finland
| | - Anna Pursiainen
- Finnish Institute for Health and Welfare, Department of Health Security, P.O. Box 95, FI-70701 Kuopio, Finland
| | - Jenni Ikonen
- Finnish Institute for Health and Welfare, Department of Health Security, P.O. Box 95, FI-70701 Kuopio, Finland
| | - Ari Kauppinen
- Finnish Institute for Health and Welfare, Department of Health Security, P.O. Box 95, FI-70701 Kuopio, Finland
| | - Ilkka T. Miettinen
- Finnish Institute for Health and Welfare, Department of Health Security, P.O. Box 95, FI-70701 Kuopio, Finland
| | - Jussi Paananen
- University of Eastern Finland, Institute of Biomedicine, P.O. Box 1627, FI-70211 Kuopio, Finland
| | - Eila Torvinen
- University of Eastern Finland, Department of Environmental and Biological Sciences, P.O. Box, 1627, FI-70211 Kuopio, Finland
| | - Mikko Kolehmainen
- University of Eastern Finland, Department of Environmental and Biological Sciences, P.O. Box, 1627, FI-70211 Kuopio, Finland
| | - Tarja Pitkänen
- Finnish Institute for Health and Welfare, Department of Health Security, P.O. Box 95, FI-70701 Kuopio, Finland
- University of Helsinki, Faculty of Veterinary Medicine, Dept. Food Hygiene and Environmental Health, Finland
| |
Collapse
|
12
|
Assessment of the Impact of Temperature on Biofilm Composition with a Laboratory Heat Exchanger Module. Microorganisms 2021; 9:microorganisms9061185. [PMID: 34072656 PMCID: PMC8229324 DOI: 10.3390/microorganisms9061185] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2021] [Revised: 05/24/2021] [Accepted: 05/26/2021] [Indexed: 11/17/2022] Open
Abstract
Temperature change over the length of heat exchangers might be an important factor affecting biofouling. This research aimed at assessing the impact of temperature on biofilm accumulation and composition with respect to bacterial community and extracellular polymeric substances. Two identical laboratory-scale plate heat exchanger modules were developed and tested. Tap water supplemented with nutrients was fed to the two modules to enhance biofilm formation. One “reference” module was kept at 20.0 ± 1.4 °C and one “heated” module was operated with a counter-flow hot water stream resulting in a bulk water gradient from 20 to 27 °C. Biofilms were grown during 40 days, sampled, and characterized using 16S rRNA gene amplicon sequencing, EPS extraction, FTIR, protein and polysaccharide quantifications. The experiments were performed in consecutive triplicate. Monitoring of heat transfer resistance in the heated module displayed a replicable biofilm growth profile. The module was shown suitable to study the impact of temperature on biofouling formation. Biofilm analyses revealed: (i) comparable amounts of biofilms and EPS yield in the reference and heated modules, (ii) a significantly different protein to polysaccharide ratio in the EPS of the reference (5.4 ± 1.0%) and heated modules (7.8 ± 2.1%), caused by a relatively lower extracellular sugar production at elevated temperatures, and (iii) a strong shift in bacterial community composition with increasing temperature. The outcomes of the study, therefore, suggest that heat induces a change in biofilm bacterial community members and EPS composition, which should be taken into consideration when investigating heat exchanger biofouling and cleaning strategies. Research potential and optimization of the heat exchanger modules are discussed.
Collapse
|
13
|
Gabrielli M, Turolla A, Antonelli M. Bacterial dynamics in drinking water distribution systems and flow cytometry monitoring scheme optimization. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2021; 286:112151. [PMID: 33609931 DOI: 10.1016/j.jenvman.2021.112151] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/24/2020] [Revised: 02/04/2021] [Accepted: 02/05/2021] [Indexed: 06/12/2023]
Abstract
Water biostability is desired within drinking water distribution systems (DWDSs) to limit microbiologically-related operational, aesthetic and, eventually, health-related issues. However, variations in microbiological quality can take place both spatially along DWDS pipelines and temporally at single locations due to biofilm detachment, water quality seasonality and other processes. In this study, long- and short-term trends of bacterial concentration and community structure were investigated in a secondary branch of an unchlorinated DWDS for several months using high-frequency flow cytometry (FCM) and traditional laboratory monitoring campaigns. Long-term trends of bacterial concentrations and community structures were likely caused by changes in the water physical-chemical quality (i.e. pH and conductivity). Short-term daily pattern, instead, resulted in significant variations between the bacterial concentrations and community structures at different hours, likely due to biofilm detachment and loose deposits resuspension related to changes in the local water flow. These patterns, however, showed broad variations and did not persist during the entire monitoring campaign presumably due to the stochasticity of local instantaneous demand and seasonal changes in water consumption. During periods without sensible long-term trends, the sampling hours explain a comparable or larger fraction of the bacterial community diversity compared to dates. The variations observed with FCM were poorly or not detected by traditional laboratory analyses, as the correlation between the two were rather weak, highlighting the limited information provided by traditional approaches. On the other hand, FCM data correlated with water pH and conductivity, underlining the relation between physical-chemical and microbiological water quality. Such results suggest that the advanced control of the physical-chemical water quality could minimize the microbiological water quality variations. Moreover, monitoring campaign planning should take into account the sampling time to reduce the noise caused by daily fluctuations and/or assess the overall quality variations. Finally, as monitoring costs are one of the barriers which prevent a more widespread use of FCM, a monitoring scheme optimization strategy was developed. Such strategy employs the data from an initial high-frequency sampling period to select the sampling hours which maximize the observed variations of bacterial concentration and community composition.
Collapse
Affiliation(s)
- Marco Gabrielli
- Politecnico di Milano, Department of Civil and Environmental Engineering (DICA), Piazza Leonardo da Vinci 32, Milano, 20133, Italy
| | - Andrea Turolla
- Politecnico di Milano, Department of Civil and Environmental Engineering (DICA), Piazza Leonardo da Vinci 32, Milano, 20133, Italy
| | - Manuela Antonelli
- Politecnico di Milano, Department of Civil and Environmental Engineering (DICA), Piazza Leonardo da Vinci 32, Milano, 20133, Italy.
| |
Collapse
|
14
|
Zhang C, Qin K, Struewing I, Buse H, Santo Domingo J, Lytle D, Lu J. The Bacterial Community Diversity of Bathroom Hot Tap Water Was Significantly Lower Than That of Cold Tap and Shower Water. Front Microbiol 2021; 12:625324. [PMID: 33967975 PMCID: PMC8102780 DOI: 10.3389/fmicb.2021.625324] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2020] [Accepted: 02/12/2021] [Indexed: 12/17/2022] Open
Abstract
Microbial drinking water quality in premise plumbing systems (PPSs) strongly affects public health. Bacterial community structure is the essential aspect of microbial water quality. Studies have elucidated the microbial community structure in cold tap water, while the microbial community structures in hot tap and shower water are poorly understood. We sampled cold tap, hot tap, and shower water from a simulated PPS monthly for 16 consecutive months and assessed the bacterial community structures in those samples via high-throughput sequencing of bacterial 16S rRNA genes. The total relative abundance of the top five most abundant phyla (Proteobacteria, Actinobacteria, Bacteroidetes, Cyanobacteria, and Firmicutes) was greater than 90% among the 24 identified phyla. The most abundant families were Burkholderiaceae, Sphingomonadaceae, unclassified Alphaproteobacteria, unclassified Corynebacteriales, and Mycobacteriaceae. A multiple linear regression suggests that the bacterial community diversity increased with water temperature and the age of the simulated PPS, decreased with total chlorine residual concentration, and had a limited seasonal variation. The bacterial community in hot tap water had significantly lower Shannon and Inverse Simpson diversity indices (p < 0.05) and thus a much lower diversity than those in cold tap and shower water. The paradoxical results (i.e., diversity increased with water temperature, but hot tap water bacterial community was less diverse) were presumably because (1) other environmental factors made hot tap water bacterial community less diverse, (2) the diversity of bacterial communities in all types of water samples increased with water temperature, and (3) the first draw samples of hot tap water could have a comparable or even lower temperature than shower water samples and the second draw samples of cold tap water. In both a three-dimensional Non-metric multidimensional scaling ordination plot and a phylogenetic dendrogram, the samples of cold tap and shower water cluster and are separate from hot tap water samples (p < 0.05). In summary, the bacterial community in hot tap water in the simulated PPS had a distinct structure from and a much lower diversity than those in cold tap and shower water.
Collapse
Affiliation(s)
- Chiqian Zhang
- Pegasus Technical Services, Inc., Cincinnati, OH, United States
| | - Ke Qin
- Oak Ridge Institute for Science and Education Participation Program, Office of Research and Development, United States Environmental Protection Agency, Cincinnati, OH, United States
| | - Ian Struewing
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, OH, United States
| | - Helen Buse
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, OH, United States
| | - Jorge Santo Domingo
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, OH, United States
| | - Darren Lytle
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, OH, United States
| | - Jingrang Lu
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, OH, United States
| |
Collapse
|
15
|
Bruno A, Sandionigi A, Magnani D, Bernasconi M, Pannuzzo B, Consolandi C, Camboni T, Labra M, Casiraghi M. Different Effects of Mineral Versus Vegetal Granular Activated Carbon Filters on the Microbial Community Composition of a Drinking Water Treatment Plant. Front Ecol Evol 2021. [DOI: 10.3389/fevo.2021.615513] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023] Open
Abstract
Drinking water quality and safety is strictly regulated and constantly monitored, but little is known about the microorganisms inhabiting drinking water treatment plants (DWTPs). This lack of knowledge prevents optimization of designs and operational controls. Here we investigated the drinking water microbial community harbored by a groundwater-derived DWTP, involving mineral and vegetal granular activated carbon filters (GACs). We used 16S rRNA gene sequencing to analyze water microbiome variations through the potabilization process, considering (i) different GAC materials and (ii) time from GAC regeneration. Our results revealed the predominance of Cand. Patescibacteria, uncultivable bacteria with limited metabolic capacities and small genomes, from source to downstream water. Microbial communities clustered per sampling date, with the noteworthy exception of groundwater samples. If the groundwater microbiome showed no significant variations over time, the community structure of water downstream GACs (both mineral and vegetal) seemed to be affected by time from GAC regeneration. Looking at a finer scale, different GAC material affected microbiome assembly over time with significant variation in the relative abundances of specific taxa. The significance of our research is in identifying the environmental microorganisms intrinsic of deep groundwater and the community shift after the perturbations induced by potabilization processes. Which microorganisms colonize different GACs and become abundant after GACs regeneration and over time is a first step toward advanced control of microbial communities, improving drinking water safety and management of operational costs.
Collapse
|
16
|
Sevillano M, Dai Z, Calus S, Bautista-de Los Santos QM, Eren AM, van der Wielen PWJJ, Ijaz UZ, Pinto AJ. Differential prevalence and host-association of antimicrobial resistance traits in disinfected and non-disinfected drinking water systems. THE SCIENCE OF THE TOTAL ENVIRONMENT 2020; 749:141451. [PMID: 32836121 DOI: 10.1016/j.scitotenv.2020.141451] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/12/2020] [Revised: 07/10/2020] [Accepted: 08/01/2020] [Indexed: 06/11/2023]
Abstract
Antimicrobial resistance (AMR) in drinking water has received less attention than its counterparts in the urban water cycle. While culture-based techniques or gene-centric PCR have been used to probe the impact of treatment approaches (e.g., disinfection) on AMR in drinking water, to our knowledge there is no systematic comparison of AMR trait distribution and prevalence between disinfected and disinfectant residual-free drinking water systems. We used metagenomics to assess the associations between disinfectant residuals and AMR prevalence and its host association in full-scale drinking water distribution systems (DWDSs) with and without disinfectant residuals. While the differences in AMR profiles between DWDSs were associated with the presence or absence of disinfectant, they were also associated with overall water chemistry and more importantly with microbial community structure. AMR genes and mechanisms differentially abundant in disinfected systems were primarily associated with nontuberculous mycobacteria (NTM). Finally, evaluation of metagenome assembled genomes (MAGs) also suggests that NTM possessing AMR genes conferring intrinsic resistance to key antibiotics were prevalent in disinfected systems, whereas such NTM genomes were not detected in disinfectant residual free DWDSs. Altogether, our findings provide insights into the drinking water resistome and its association with potential opportunistic pathogens, particularly in systems with disinfectant residual.
Collapse
Affiliation(s)
- Maria Sevillano
- Department of Civil and Environmental Engineering, Northeastern University, Boston, MA, USA
| | - Zihan Dai
- Infrastructure and Environmental Research Division, School of Engineering, University of Glasgow, G12 8LT Glasgow, UK
| | - Szymon Calus
- Infrastructure and Environmental Research Division, School of Engineering, University of Glasgow, G12 8LT Glasgow, UK
| | | | - A Murat Eren
- Department of Medicine, University of Chicago, Chicago, IL, USA; Bay Paul Center, Marine Biological Laboratory, Woods Hole, MA, USA
| | - Paul W J J van der Wielen
- KWR Watercycle Research Institute, Nieuwegein, Netherlands; Laboratory of Microbiology, Wageningen University, Wageningen, Netherlands
| | - Umer Z Ijaz
- Infrastructure and Environmental Research Division, School of Engineering, University of Glasgow, G12 8LT Glasgow, UK
| | - Ameet J Pinto
- Department of Civil and Environmental Engineering, Northeastern University, Boston, MA, USA.
| |
Collapse
|
17
|
Zhang C, Xu P, Wang XC, Xu L. Bacterial viability and diversity in a landscape lake replenished with reclaimed water: a case study in Xi'an, China. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2020; 27:32796-32808. [PMID: 32519106 DOI: 10.1007/s11356-020-08910-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/28/2019] [Accepted: 04/16/2020] [Indexed: 06/11/2023]
Abstract
To understand the characteristics of bacterial viability and diversity in landscape waters replenished with reclaimed water, the typical landscape lake using reclaimed water was investigated in this study. Samples were collected from a reclaimed water inlet (P1), a reclaimed water distribution outlet (P2), and a landscape lake replenished by reclaimed water (P3). By means of measuring adenosine triphosphate (ATP), flow cytometry (FCM), and 16S rRNA gene high-throughput sequencing, the bacterial viability and diversity in reclaimed water distribution system and landscape lake were illustrated. The bacterial ATP contents at P1, P2, and P3 were 3.55 ± 1.79 ng/L, 3.31 ± 1.43 ng/L, and 18.97 ± 6.39 μg/L, and the intact bacterial cell concentrations were 5.91 ± 0.52 × 104 cells/mL, 7.95 ± 2.58 × 104 cells/mL, and 5.65 ± 2.10 × 106 cells/mL, respectively. These results indicated a significant increase of bacterial viability in the landscape lake. The Shannon diversity index of 6.535, 7.05, and 6.886 at P1, P2, and P3, respectively, demonstrated no notable change of bacterial diversity from reclaimed water distribution system to landscape lake. However, the relative abundance of Pseudomonas sp. at P3 was significantly higher than that at P1. These findings indicated that viable but non-culturable (VBNC) bacteria could be revived in the landscape lake. The bacterial viability during reclaimed water reuse should deserve special attention.
Collapse
Affiliation(s)
- Chongmiao Zhang
- International Science and Technology Cooperation Center for Urban Alternative Water Resources Development, Xi'an University of Architecture and Technology, Xi'an, 710055, China.
- Key Lab of Northwest Water Resource, Environment and Ecology, Ministry of Education, Xi'an University of Architecture and Technology, Xi'an, 710055, China.
- Engineering Technology Research Center for Wastewater Treatment and Reuse, Xi'an University of Architecture and Technology, Xi'an, 710055, China.
- Shaanxi Key Laboratory of Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an, 710055, China.
| | - Pengcheng Xu
- International Science and Technology Cooperation Center for Urban Alternative Water Resources Development, Xi'an University of Architecture and Technology, Xi'an, 710055, China
- Key Lab of Northwest Water Resource, Environment and Ecology, Ministry of Education, Xi'an University of Architecture and Technology, Xi'an, 710055, China
- Engineering Technology Research Center for Wastewater Treatment and Reuse, Xi'an University of Architecture and Technology, Xi'an, 710055, China
- Shaanxi Key Laboratory of Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an, 710055, China
| | - Xiaochang C Wang
- International Science and Technology Cooperation Center for Urban Alternative Water Resources Development, Xi'an University of Architecture and Technology, Xi'an, 710055, China.
- Key Lab of Northwest Water Resource, Environment and Ecology, Ministry of Education, Xi'an University of Architecture and Technology, Xi'an, 710055, China.
- Engineering Technology Research Center for Wastewater Treatment and Reuse, Xi'an University of Architecture and Technology, Xi'an, 710055, China.
- Shaanxi Key Laboratory of Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an, 710055, China.
| | - Limei Xu
- International Science and Technology Cooperation Center for Urban Alternative Water Resources Development, Xi'an University of Architecture and Technology, Xi'an, 710055, China
- Key Lab of Northwest Water Resource, Environment and Ecology, Ministry of Education, Xi'an University of Architecture and Technology, Xi'an, 710055, China
- Engineering Technology Research Center for Wastewater Treatment and Reuse, Xi'an University of Architecture and Technology, Xi'an, 710055, China
- Shaanxi Key Laboratory of Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an, 710055, China
| |
Collapse
|
18
|
Chen X, Wang Y, Li W, Zhao X, Lu Y, Yu Y, Chen S, Ding Z. Microbial contamination in distributed drinking water purifiers induced by water stagnation. ENVIRONMENTAL RESEARCH 2020; 188:109715. [PMID: 32505883 DOI: 10.1016/j.envres.2020.109715] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/18/2020] [Revised: 05/19/2020] [Accepted: 05/19/2020] [Indexed: 06/11/2023]
Abstract
Small-scale distributed water purifiers (SSDWPs), providing better quality drinking water, are popularly used both in homes and in the public domain. Non-continuous operation leads to water stagnation and ultimately induces microbial contamination. However, information related to such contamination in these purifiers is reported scarcely. In the present study, an SSDWP, consisting of sand filtration (SF), granular activated carbon (GAC), and ultrafiltration (UF) processes, was established to explore microbial changes induced by water stagnation, based on the aspects of bacterial count, microbial size, microbiome and pathogenic communities. Our results primary showed that: first, compared with drinking water distribution system (DWDS), bacterial counts increased more rapidly in SSDWPs, growing to > 500 cfu/mL after 2.5 h stagnation. The proportion of intact cells also increased with stagnation time. Conversely, microbial size decreased with stagnation time according to changes in forward scatter detected using flow cytometry. Second, microbiome evolution followed the isolated island model, while in stagnated DWDS, microbiome evolved according to the continent island model, and the former had higher abundance of biodiversity. Furthermore, stagnation evidently caused microbiome changes in each unit, and spatial differences contributed to microbiome dissimilarity more significantly than temporal differences. Third, Mycobacterium was the dominant pathogenic genus in the SF and GAC units while Acinetobacter was the most abundant in the UF unit. Pathogenic risks increased with water stagnation time and lower nutrients level contributed to pathogenic community richness. Therefore, terminal disinfection of SSDWPs is strongly advised.
Collapse
Affiliation(s)
- Xiao Chen
- College of Defense Engineering, The Army Engineering University of PLA, Nanjing, 210007, China
| | - Yi Wang
- College of Defense Engineering, The Army Engineering University of PLA, Nanjing, 210007, China.
| | - Weiying Li
- State Key Laboratory of Pollution Control and Resource Reuse, Tongji University, Shanghai, 200092, China; College of Environmental Science and Engineering, Tongji University, Shanghai, 200092, China
| | - Xiaolan Zhao
- College of Defense Engineering, The Army Engineering University of PLA, Nanjing, 210007, China
| | - Yaofeng Lu
- College of Defense Engineering, The Army Engineering University of PLA, Nanjing, 210007, China
| | - Yingjun Yu
- College of Defense Engineering, The Army Engineering University of PLA, Nanjing, 210007, China
| | - Sheng Chen
- College of Environmental Science and Engineering, Tongji University, Shanghai, 200092, China
| | - Zhibin Ding
- College of Defense Engineering, The Army Engineering University of PLA, Nanjing, 210007, China.
| |
Collapse
|
19
|
Zhou X, Ahmad JI, van der Hoek JP, Zhang K. Thermal energy recovery from chlorinated drinking water distribution systems: Effect on chlorine and microbial water and biofilm characteristics. ENVIRONMENTAL RESEARCH 2020; 187:109655. [PMID: 32450425 DOI: 10.1016/j.envres.2020.109655] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/23/2020] [Revised: 04/09/2020] [Accepted: 05/08/2020] [Indexed: 06/11/2023]
Abstract
Thermal energy recovery from drinking water has a high potential in the application of sustainable building and industrial cooling. However, drinking water and biofilm microbial qualities should be concerned because the elevated water temperature after cold recovery may influence the microbial activities in water and biofilm phases in drinking water distribution systems (DWDSs). In this study, the effect of cold recovery on microbial qualities was investigated in a chlorinated DWDS. The chlorine decay was slight (1.1%-15.5%) due to a short contact time (~60 s) and was not affected by the cold recovery (p > 0.05). The concentrations of cellular ATP and intact cell numbers in the bulk water were partially inactivated by the residual chlorine, with the removal rates of 10.1%-16.2% and 22.4%-29.4%, respectively. The chlorine inactivation was probably promoted by heat exchangers but was not further enhanced by higher temperatures. The higher water temperature (25 °C) enhanced the growth of biofilm biomass on pipelines. Principle coordination analysis (PCoA) showed that the biofilms on the stainless steel plates of HEs and the plastic pipe inner surfaces had totally different community compositions. Elevated temperatures favored the growth of Pseudomonas spp. and Legionella spp. in the biofilm after cold recovery. The community functional predictions revealed more abundances of five human diseases (e.g. Staphylococcis aureus infection) and beta-lactam resistance pathways in the biofilms at higher temperature. Compared with a previous study with a non-chlorinated DWDS, chlorine dramatically reduced the biofilm biomass growth but raised the relative abundances of the chlorine-resistant genera (i.e. Pseudomonas and Sphingomonas) in bacterial communities.
Collapse
Affiliation(s)
- Xinyan Zhou
- College of Civil Engineering and Architecture, Zhejiang University, Hangzhou, 310058, Zhejiang, China; Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600GA, Delft, the Netherlands
| | - Jawairia Imtiaz Ahmad
- Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600GA, Delft, the Netherlands; Institute of Environmental Sciences and Engineering, School of Civil and Environmental Engineering, National University of Science and Technology, H-12 Sector, Islamabad, Pakistan
| | - Jan Peter van der Hoek
- Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600GA, Delft, the Netherlands; Waternet, Korte Ouderkerkerdijk 7, 1096 AC, Amsterdam, the Netherlands
| | - Kejia Zhang
- College of Civil Engineering and Architecture, Zhejiang University, Hangzhou, 310058, Zhejiang, China.
| |
Collapse
|
20
|
The impact of metal pipe materials, corrosion products, and corrosion inhibitors on antibiotic resistance in drinking water distribution systems. Appl Microbiol Biotechnol 2020; 104:7673-7688. [DOI: 10.1007/s00253-020-10777-8] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2020] [Revised: 06/29/2020] [Accepted: 07/05/2020] [Indexed: 02/07/2023]
|
21
|
Feeding the Building Plumbing Microbiome: The Importance of Synthetic Polymeric Materials for Biofilm Formation and Management. WATER 2020. [DOI: 10.3390/w12061774] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
The environmental conditions in building plumbing systems differ considerably from the larger distribution system and, as a consequence, uncontrolled changes in the drinking water microbiome through selective growth can occur. In this regard, synthetic polymeric plumbing materials are of particular relevance, since they leach assimilable organic carbon that can be utilized for bacterial growth. Here, we discuss the complexity of building plumbing in relation to microbial ecology, especially in the context of low-quality synthetic polymeric materials (i.e., plastics) and highlight the major knowledge gaps in the field. We furthermore show how knowledge on the interaction between material properties (e.g., carbon migration) and microbiology (e.g., growth rate) allows for the quantification of initial biofilm development in buildings. Hence, research towards a comprehensive understanding of these processes and interactions will enable the implementation of knowledge-based management strategies. We argue that the exclusive use of high-quality materials in new building plumbing systems poses a straightforward strategy towards managing the building plumbing microbiome. This can be achieved through comprehensive material testing and knowledge sharing between all stakeholders including architects, planners, plumbers, material producers, home owners, and scientists.
Collapse
|
22
|
Bastaraud A, Perthame E, Rakotondramanga JM, Mahazosaotra J, Ravaonindrina N, Jambou R. The impact of rainfall on drinking water quality in Antananarivo, Madagascar. PLoS One 2020; 15:e0218698. [PMID: 32542001 PMCID: PMC7295214 DOI: 10.1371/journal.pone.0218698] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2019] [Accepted: 04/06/2020] [Indexed: 01/23/2023] Open
Abstract
Low-income cities that are subject to high population pressure and vulnerable to climate events often have a low capacity to continuously deliver safe drinking water. Here we reported the results of a 32-year survey on the temporal dynamics of drinking water quality indicators in the city of Antananarivo. We analyzed the long-term evolution of the quality of the water supplied and characterized the interactions between climatic conditions and the full-scale water supply system. A total of 25,467 water samples were collected every week at different points in the supplied drinking water system. Samples were analyzed for total coliforms (TC), Escherichia coli (EC), intestinal Enterococci (IE), and Spores of Sulphite-Reducing Clostridia (SSRC). Nine-hundred-eighty-one samples that were identified as positive for one or more indicators were unevenly distributed over time. The breakpoint method identified four periods when the time series displayed changes in the level and profile of contamination (i) and the monthly pattern of contamination (ii), with more direct effects of rainfall on the quality of supplied drinking water. The modeling showed significantly different lags among indicators of bacteria occurrence after cumulative rainfall, which range from 4 to 8 weeks. Among the effects of low-income urbanization, a rapid demographic transition and the degradation of urban watersheds have gradually affected the quality of the water supplied and resulted in the more direct effects of rainfall events. We focused on the need to adopt an alternative perspective of drinking water and urban watersheds management.
Collapse
Affiliation(s)
- Alexandra Bastaraud
- Food Hygiene and Environment Laboratory, Institut Pasteur of Madagascar, Antananarivo, Madagascar
| | - Emeline Perthame
- The Center of Bioinformatics, Biostatistics and Integrative Biology (C3BI), Institut Pasteur Paris, Paris, France
| | | | - Jackson Mahazosaotra
- Food Hygiene and Environment Laboratory, Institut Pasteur of Madagascar, Antananarivo, Madagascar
| | - Noro Ravaonindrina
- Food Hygiene and Environment Laboratory, Institut Pasteur of Madagascar, Antananarivo, Madagascar
| | - Ronan Jambou
- Global Health Department, Institut Pasteur Paris, Paris, France
- * E-mail:
| |
Collapse
|
23
|
Potgieter SC, Dai Z, Venter SN, Sigudu M, Pinto AJ. Microbial Nitrogen Metabolism in Chloraminated Drinking Water Reservoirs. mSphere 2020; 5:e00274-20. [PMID: 32350093 PMCID: PMC7193043 DOI: 10.1128/msphere.00274-20] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2020] [Accepted: 04/09/2020] [Indexed: 01/04/2023] Open
Abstract
Ammonia availability due to chloramination can promote the growth of nitrifying organisms, which can deplete chloramine residuals and result in operational problems for drinking water utilities. In this study, we used a metagenomic approach to determine the identity and functional potential of microorganisms involved in nitrogen biotransformation within chloraminated drinking water reservoirs. Spatial changes in the nitrogen species included an increase in nitrate concentrations accompanied by a decrease in ammonium concentrations with increasing distance from the site of chloramination. This nitrifying activity was likely driven by canonical ammonia-oxidizing bacteria (i.e., Nitrosomonas) and nitrite-oxidizing bacteria (i.e., Nitrospira) as well as by complete-ammonia-oxidizing (i.e., comammox) Nitrospira-like bacteria. Functional annotation was used to evaluate genes associated with nitrogen metabolism, and the community gene catalogue contained mostly genes involved in nitrification, nitrate and nitrite reduction, and nitric oxide reduction. Furthermore, we assembled 47 high-quality metagenome-assembled genomes (MAGs) representing a highly diverse assemblage of bacteria. Of these, five MAGs showed high coverage across all samples, which included two Nitrosomonas, Nitrospira, Sphingomonas, and Rhizobiales-like MAGs. Systematic genome-level analyses of these MAGs in relation to nitrogen metabolism suggest that under ammonia-limited conditions, nitrate may be also reduced back to ammonia for assimilation. Alternatively, nitrate may be reduced to nitric oxide and may potentially play a role in regulating biofilm formation. Overall, this study provides insight into the microbial communities and their nitrogen metabolism and, together with the water chemistry data, improves our understanding of nitrogen biotransformation in chloraminated drinking water distribution systems.IMPORTANCE Chloramines are often used as a secondary disinfectant when free chlorine residuals are difficult to maintain. However, chloramination is often associated with the undesirable effect of nitrification, which results in operational problems for many drinking water utilities. The introduction of ammonia during chloramination provides a potential source of nitrogen either through the addition of excess ammonia or through chloramine decay. This promotes the growth of nitrifying microorganisms and provides a nitrogen source (i.e., nitrate) for the growth for other organisms. While the roles of canonical ammonia-oxidizing and nitrite-oxidizing bacteria in chloraminated drinking water systems have been extensively investigated, those studies have largely adopted a targeted gene-centered approach. Further, little is known about the potential long-term cooccurrence of complete-ammonia-oxidizing (i.e., comammox) bacteria and the potential metabolic synergies of nitrifying organisms with their heterotrophic counterparts that are capable of denitrification and nitrogen assimilation. This study leveraged data obtained for genome-resolved metagenomics over a time series to show that while nitrifying bacteria are dominant and likely to play a major role in nitrification, their cooccurrence with heterotrophic organisms suggests that nitric oxide production and nitrate reduction to ammonia may also occur in chloraminated drinking water systems.
Collapse
Affiliation(s)
- Sarah C Potgieter
- Department of Biochemistry, Genetics and Microbiology, University of Pretoria, Pretoria, South Africa
| | - Zihan Dai
- Infrastructure and Environment Division, School of Engineering, University of Glasgow, Glasgow, United Kingdom
| | - Stephanus N Venter
- Department of Biochemistry, Genetics and Microbiology, University of Pretoria, Pretoria, South Africa
| | | | - Ameet J Pinto
- Department of Civil and Environmental Engineering, Northeastern University, Boston, Massachusetts, USA
| |
Collapse
|
24
|
Hoogenkamp MA, Brandt BW, de Soet JJ, Crielaard W. An in-vitro dynamic flow model for translational research into dental unit water system biofilms. J Microbiol Methods 2020; 171:105879. [DOI: 10.1016/j.mimet.2020.105879] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2019] [Revised: 02/14/2020] [Accepted: 02/22/2020] [Indexed: 12/18/2022]
|
25
|
Ahmad JI, Liu G, van der Wielen PWJJ, Medema G, Peter van der Hoek J. Effects of cold recovery technology on the microbial drinking water quality in unchlorinated distribution systems. ENVIRONMENTAL RESEARCH 2020; 183:109175. [PMID: 31999996 DOI: 10.1016/j.envres.2020.109175] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2019] [Revised: 01/22/2020] [Accepted: 01/22/2020] [Indexed: 06/10/2023]
Abstract
Drinking water distribution systems (DWDSs) are used to supply hygienically safe and biologically stable water for human consumption. The potential of thermal energy recovery from drinking water has been explored recently to provide cooling for buildings. Yet, the effects of increased water temperature induced by this "cold recovery" on the water quality in DWDSs are not known. The objective of this study was to investigate the impact of cold recovery from DWDSs on the microbiological quality of drinking water. For this purpose, three pilot distribution systems were operated in parallel for 38 weeks. System 1 has an operational heat exchanger, mimicking the cold recovery system by maintaining the water temperature at 25 °C; system 2 operated with a non-operational heat exchanger and system 3 run without heat exchanger. The results showed no significant effects on drinking water quality: cell numbers and ATP concentrations remained around 3.5 × 105 cells/ml and 4 ng ATP/l, comparable observed operational taxonomic units (OTUs) (~470-490) and similar Shannon indices (7.7-8.9). In the system with cold recovery, a higher relative abundance of Pseudomonas spp. and Chryseobacterium spp. was observed in the drinking water microbial community, but only when the cold recovery induced temperature difference (ΔT) was higher than 9 °C. In the 38 weeks' old biofilm, higher ATP concentration (475 vs. 89 pg/cm2), lower diversity (observed OTUs: 88 vs. ≥200) and a different bacterial community composition (e.g. higher relative abundance of Novosphingobium spp.) were detected, which did not influence water quality. No impacts were observed for the selected opportunisitic pathogens after introducing cold recovery. It is concluded that cold recovery does not affect bacterial water quality. Further investigation for a longer period is commended to understand the dynamic responses of biofilm to the increased temperature caused by cold recovery.
Collapse
Affiliation(s)
- Jawairia Imtiaz Ahmad
- Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600GA, Delft, the Netherlands; Institute of Environmental Sciences and Engineering, School of Civil and Environmental Engineering, National University of Science and Technology, H-12 Sector, Islamabad, Pakistan
| | - Gang Liu
- Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600GA, Delft, the Netherlands; Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, PR China.
| | - Paul W J J van der Wielen
- KWR Watercycle Research Institute, P.O. Box 1072, 3430 BB, Nieuwegein, the Netherlands; Laboratory of Microbiology, Wageningen University, P.O. Box 8033, 6700, EH, Wageningen, the Netherlands
| | - Gertjan Medema
- Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600GA, Delft, the Netherlands; KWR Watercycle Research Institute, P.O. Box 1072, 3430 BB, Nieuwegein, the Netherlands; Michigan State University, 1405, S Harrison Rd East-Lansing, 48823, USA
| | - Jan Peter van der Hoek
- Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600GA, Delft, the Netherlands; Waternet, Korte Ouderkerkerdijk 7, 1096 AC, Amsterdam, the Netherlands
| |
Collapse
|
26
|
Favere J, Buysschaert B, Boon N, De Gusseme B. Online microbial fingerprinting for quality management of drinking water: Full-scale event detection. WATER RESEARCH 2020; 170:115353. [PMID: 31881501 DOI: 10.1016/j.watres.2019.115353] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/12/2019] [Revised: 11/08/2019] [Accepted: 11/27/2019] [Indexed: 06/10/2023]
Abstract
Microbial regrowth during drinking water distribution can result in a variety of problems such as a deviating taste and odor, and may even pose a risk to public health. Frequent monitoring is essential to anticipate events of biological instability, and relevant microbial parameters for operational control of biostability of drinking water should be developed. Here, online flow cytometry and derived biological metrics were used to assess the biological stability of a full-scale drinking water tower during normal and disturbed flow regime. Pronounced operational events, such as switching from drinking water source, and seasonal changes, were detected in the total cell counts, and regrowth was observed despite the short hydraulic residence time of 6-8 h. Based on the flow cytometric fingerprints, the Bray-Curtis dissimilarity was calculated and was developed as unambiguous parameter to indicate or warn for changing microbial drinking water quality during operational events. In the studied water tower, drastic microbial water quality changes were reflected in the Bray-Curtis dissimilarity, which demonstrates its use as an indicator to follow-up and detect microbial quality changes in practice. Hence, the Bray-Curtis dissimilarity can be used in an online setup as a straightforward parameter during full-scale operation of drinking water distribution, and combined with the cell concentration, it serves as an early-warning system for biological instability.
Collapse
Affiliation(s)
- Jorien Favere
- Center for Microbial Ecology and Technology (CMET), Department of Biochemical and Microbial Technology, Ghent University, Coupure Links 653, B-9000, Gent, Belgium
| | | | - Nico Boon
- Center for Microbial Ecology and Technology (CMET), Department of Biochemical and Microbial Technology, Ghent University, Coupure Links 653, B-9000, Gent, Belgium
| | - Bart De Gusseme
- Center for Microbial Ecology and Technology (CMET), Department of Biochemical and Microbial Technology, Ghent University, Coupure Links 653, B-9000, Gent, Belgium; FARYS, TMVW, Stropstraat 1, B-9000, Gent, Belgium.
| |
Collapse
|
27
|
Mapping Dynamics of Bacterial Communities in a Full-Scale Drinking Water Distribution System Using Flow Cytometry. WATER 2019. [DOI: 10.3390/w11102137] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Microbial monitoring of drinking water is required to guarantee high quality water and to mitigate health hazards. Flow cytometry (FCM) is a fast and robust method that determines bacterial concentrations in liquids. In this study, FCM was applied to monitor the dynamics of the bacterial communities over one year in a full-scale drinking water distribution system (DWDS), following implementation of ultrafiltration (UF) combined with coagulation at the drinking water treatment plant (DWTP). Correlations between the environmental conditions in the DWDS and microbial regrowth were observed, including increases in total cell counts with increasing retention time (correlation coefficient R = 0.89) and increasing water temperature (up to 5.24-fold increase in cell counts during summer). Temporal and spatial biofilm dynamics affecting the water within the DWDS were also observed, such as changes in the percentage of high nucleic acid bacteria with increasing retention time (correlation coefficient R = −0.79). FCM baselines were defined for specific areas in the DWDS to support future management strategies in this DWDS, including a gradual reduction of chloramine.
Collapse
|
28
|
Understanding the impacts of intermittent supply on the drinking water microbiome. Curr Opin Biotechnol 2019; 57:167-174. [PMID: 31100615 DOI: 10.1016/j.copbio.2019.04.003] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2018] [Revised: 04/14/2019] [Accepted: 04/15/2019] [Indexed: 11/21/2022]
Abstract
Increasing access to piped water in low-income and middle-income countries combined with the many factors that threaten our drinking water supply infrastructure mean that intermittent water supply (IWS) will remain a common practice around the world. Common features of IWS include water stagnation, pipe drainage, intrusion, backflow, first flush events, and household storage. IWS has been shown to cause degradation as measured by traditional microbial water quality indicators. In this review, we build on new insights into the microbial ecology of continuous water supply systems revealed by sequencing methods to speculate about how intermittent supply conditions may further influence the drinking water microbiome, and identify priorities for future research.
Collapse
|
29
|
Li RA, McDonald JA, Sathasivan A, Khan SJ. Disinfectant residual stability leading to disinfectant decay and by-product formation in drinking water distribution systems: A systematic review. WATER RESEARCH 2019; 153:335-348. [PMID: 30743084 DOI: 10.1016/j.watres.2019.01.020] [Citation(s) in RCA: 59] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2018] [Revised: 01/02/2019] [Accepted: 01/04/2019] [Indexed: 06/09/2023]
Abstract
Secondary disinfectants, such as chlorine and chloramine, have been widely applied to minimise microbial risks in drinking water during distribution. Key challenges have included the maintenance of stable concentrations of disinfectant residuals and the control of disinfection by-products that may form as a consequence of residual decay processes. Many factors may influence disinfectant residual stability and the consequential formation of by-products. Thus predictions of disinfectant stability and by-product formation are multifactorial problems, complete with numerous complications of parameter co-dependence and feedback amplification of some key parameters. The aim of this review was to derive an understanding of how disinfectant residual stability in drinking water distribution systems is impacted by various influencing factors such as water quality and operational parameters. Factors known to influence disinfectant stability and by-product formation were critically reviewed. A systematic review method was applied to identify 1809 journal articles published in the two decades from January 1998 to December 2017. From the initial screening, 161 papers were selected for detailed assessment. Important factors were identified to include temperature, water age, piping material, corrosion products, pH, hydraulic condition, disinfectant residual type and dosage and microbial activity. Microbial activity is a particularly complex parameter on which to base predictions since many factors are known to influence the degree and nature of such activity. These include temperature, water age, piping material, corrosion products, nutrients, natural organic matter, hydraulic condition and disinfectant residual type and dosage. Disinfectant types and dosages were found to be among the most important factors. Many knowledge gaps and research needs still remain, including the need for a more complete understanding of the factors that influence the production of nitrogenous disinfection by-products.
Collapse
Affiliation(s)
- Rebecca A Li
- UNSW Water Research Centre, School of Civil & Environmental Engineering, University of New South Wales, NSW, 2052, Australia.
| | - James A McDonald
- UNSW Water Research Centre, School of Civil & Environmental Engineering, University of New South Wales, NSW, 2052, Australia.
| | - Arumugam Sathasivan
- School of Computing Engineering and Mathematics, University of Western Sydney, Kingswood, NSW, 2747, Australia.
| | - Stuart J Khan
- UNSW Water Research Centre, School of Civil & Environmental Engineering, University of New South Wales, NSW, 2052, Australia.
| |
Collapse
|
30
|
A novel method: using an adenosine triphosphate (ATP) luminescence-based assay to rapidly assess the biological stability of drinking water. Appl Microbiol Biotechnol 2019; 103:4269-4277. [PMID: 30972459 DOI: 10.1007/s00253-019-09774-3] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2018] [Revised: 03/15/2019] [Accepted: 03/15/2019] [Indexed: 10/27/2022]
Abstract
The rapid and credible evaluations of the microbial stability of a drinking water distribution system (DWDS) are of great significance for ensuring the safety of drinking water and predicting microbial pollution. Conventional biostability assessment methods mainly focus on bacterial regrowth or evaluation of the level of nutrients that support bacterial regrowth. However, such methods are time-consuming and have many limitations. An adenosine triphosphate (ATP) assay can rapidly measure all active microorganisms and is known to be a useful method to assess the microbial activity of drinking water. The measurement of ATP has been used for more than a decade in the field of drinking water research. This article reviews the application of an ATP luminescence-based method to assess the biostability of drinking water and discusses the feasibility of ATP measurement as a parameter for quickly evaluating this criterion. ATP measurement will help researchers and water managers better monitor the biological stability of drinking water from the source to the consumer's tap. This review covers the: (1) principle and application of the ATP measurement in drinking water quality assessment; (2) comparison of the merits and demerits of several methods for evaluating the biostability of drinking water; (3) discussions on using ATP measurement in evaluating biostability; and (4) improvements in the use of ATP measurement in evaluating biostability. At the end of this review, recommendations were given for better application of the ATP measurement as a parameter for monitoring the microbial quality of drinking water.
Collapse
|
31
|
Safford HR, Bischel HN. Flow cytometry applications in water treatment, distribution, and reuse: A review. WATER RESEARCH 2019; 151:110-133. [PMID: 30594081 DOI: 10.1016/j.watres.2018.12.016] [Citation(s) in RCA: 55] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/05/2018] [Revised: 11/30/2018] [Accepted: 12/01/2018] [Indexed: 06/09/2023]
Abstract
Ensuring safe and effective water treatment, distribution, and reuse requires robust methods for characterizing and monitoring waterborne microbes. Methods widely used today can be limited by low sensitivity, high labor and time requirements, susceptibility to interference from inhibitory compounds, and difficulties in distinguishing between viable and non-viable cells. Flow cytometry (FCM) has recently gained attention as an alternative approach that can overcome many of these challenges. This article critically and systematically reviews for the first time recent literature on applications of FCM in water treatment, distribution, and reuse. In the review, we identify and examine nearly 300 studies published from 2000 to 2018 that illustrate the benefits and challenges of using FCM for assessing source-water quality and impacts of treatment-plant discharge on receiving waters, wastewater treatment, drinking water treatment, and drinking water distribution. We then discuss options for combining FCM with other indicators of water quality and address several topics that cut across nearly all applications reviewed. Finally, we identify priority areas in which more work is needed to realize the full potential of this approach. These include optimizing protocols for FCM-based analysis of waterborne viruses, optimizing protocols for specifically detecting target pathogens, automating sample handling and preparation to enable real-time FCM, developing computational tools to assist data analysis, and improving standards for instrumentation, methods, and reporting requirements. We conclude that while more work is needed to realize the full potential of FCM in water treatment, distribution, and reuse, substantial progress has been made over the past two decades. There is now a sufficiently large body of research documenting successful applications of FCM that the approach could reasonably and realistically see widespread adoption as a routine method for water quality assessment.
Collapse
Affiliation(s)
- Hannah R Safford
- Department of Civil and Environmental Engineering, University of California Davis, 2001 Ghausi Hall, 480 Bainer Hall Drive, 95616, Davis, CA, United States
| | - Heather N Bischel
- Department of Civil and Environmental Engineering, University of California Davis, 2001 Ghausi Hall, 480 Bainer Hall Drive, 95616, Davis, CA, United States.
| |
Collapse
|
32
|
Bacterial release from pipe biofilm in a full-scale drinking water distribution system. NPJ Biofilms Microbiomes 2019; 5:9. [PMID: 30820334 PMCID: PMC6385293 DOI: 10.1038/s41522-019-0082-9] [Citation(s) in RCA: 65] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2018] [Accepted: 01/28/2019] [Indexed: 11/13/2022] Open
Abstract
Safe drinking water is delivered to the consumer through kilometres of pipes. These pipes are lined with biofilm, which is thought to affect water quality by releasing bacteria into the drinking water. This study describes the number of cells released from this biofilm, their cellular characteristics, and their identity as they shaped a drinking water microbiome. Installation of ultrafiltration (UF) at full scale in Varberg, Sweden reduced the total cell count to 1.5 × 103 ± 0.5 × 103 cells mL−1 in water leaving the treatment plant. This removed a limitation of both flow cytometry and 16S rRNA amplicon sequencing, which have difficulties in resolving small changes against a high background cell count. Following installation, 58% of the bacteria in the distributed water originated from the pipe biofilm, in contrast to before, when 99.5% of the cells originated from the treatment plant, showing that UF shifts the origin of the drinking water microbiome. The number of bacteria released from the biofilm into the distributed water was 2.1 × 103 ± 1.3 × 103 cells mL−1 and the percentage of HNA (high nucleic acid) content bacteria and intact cells increased as it moved through the distribution system. DESeq2 analysis of 16S rRNA amplicon reads showed increases in 29 operational taxonomic units (OTUs), including genera identified as Sphingomonas, Nitrospira, Mycobacterium, and Hyphomicrobium. This study demonstrated that, due to the installation of UF, the bacteria entering a drinking water microbiome from a pipe biofilm could be both quantitated and described.
Collapse
|
33
|
Perrin Y, Bouchon D, Delafont V, Moulin L, Héchard Y. Microbiome of drinking water: A full-scale spatio-temporal study to monitor water quality in the Paris distribution system. WATER RESEARCH 2019; 149:375-385. [PMID: 30471533 DOI: 10.1016/j.watres.2018.11.013] [Citation(s) in RCA: 58] [Impact Index Per Article: 11.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/18/2018] [Revised: 10/25/2018] [Accepted: 11/05/2018] [Indexed: 05/22/2023]
Abstract
The microbiological water quality of drinking water distribution system (DWDS) is of primary importance for human health. High-throughput sequencing has gained more and more attention in the last decade to describe this microbial diversity in water networks. However, there are few studies describing this approach on large drinking water distribution systems and for extended periods of time. To fill this gap and observe the potential subtle variation in microbiota of a water network through time and space, we aimed to apply high-throughput sequencing of the 16S rRNA gene approach to characterize bacterial communities of the Paris' DWDS over a one-year period. In this study, the Paris network, composed of four different DWDSs, was sampled at 31 sites, each month for one year. The sampling campaign was one of the largest described so far (n = 368) and the importance of key spatio-temporal and physico-chemical parameters was investigated. Overall, 1321 taxa were identified within the Paris network, although only fifteen of them were found in high relative abundance (>1%) in all samples. Two genera, Phreatobacter and Hyphomicrobium were dominant. The whole bacterial diversity was not significantly affected between the four DWDSs (spatial parameter) and by physico-chemical parameters. However, the bacterial diversity was slightly modified over the one-year period (temporal parameter) as we were able to observe DWDS microbiome perturbations, presumably linked to a preceding flood event. Comparison of high-throughput sequencing of the 16S rRNA gene amplicons vs. cultivation-based techniques showed that only 1.8% of bacterial diversity was recovered through cultivation. High throughput sequencing has made it possible to monitor DWDS more accurately than conventional methods by describing the whole diversity and detecting slight fluctuations in bacterial communities. This method would be further used to supervise drinking water networks, to follow any perturbations due to internals events (such as treatments) or external events (such as flooding).
Collapse
Affiliation(s)
- Yoann Perrin
- Laboratoire Ecologie et Biologie des Interactions, Equipes Microbiologie de l'Eau, et., Ecologie, Evolution, Symbiose, Université de Poitiers, UMR CNRS 7267, F-86073, Poitiers, France; Eau de Paris, Direction de la Recherche et du Développement pour la Qualité de l'Eau, R&D Biologie, 33, Avenue Jean Jaurès, F-94200, Ivry sur Seine, France
| | - Didier Bouchon
- Laboratoire Ecologie et Biologie des Interactions, Equipes Microbiologie de l'Eau, et., Ecologie, Evolution, Symbiose, Université de Poitiers, UMR CNRS 7267, F-86073, Poitiers, France
| | - Vincent Delafont
- Laboratoire Ecologie et Biologie des Interactions, Equipes Microbiologie de l'Eau, et., Ecologie, Evolution, Symbiose, Université de Poitiers, UMR CNRS 7267, F-86073, Poitiers, France
| | - Laurent Moulin
- Eau de Paris, Direction de la Recherche et du Développement pour la Qualité de l'Eau, R&D Biologie, 33, Avenue Jean Jaurès, F-94200, Ivry sur Seine, France.
| | - Yann Héchard
- Laboratoire Ecologie et Biologie des Interactions, Equipes Microbiologie de l'Eau, et., Ecologie, Evolution, Symbiose, Université de Poitiers, UMR CNRS 7267, F-86073, Poitiers, France.
| |
Collapse
|
34
|
Whitton R, Fane S, Jarvis P, Tupper M, Raffin M, Coulon F, Nocker A. Flow cytometry-based evaluation of the bacterial removal efficiency of a blackwater reuse treatment plant and the microbiological changes in the associated non-potable distribution network. THE SCIENCE OF THE TOTAL ENVIRONMENT 2018; 645:1620-1629. [PMID: 30248879 DOI: 10.1016/j.scitotenv.2018.07.121] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/12/2018] [Revised: 06/10/2018] [Accepted: 07/10/2018] [Indexed: 06/08/2023]
Abstract
The study evaluated the changes in bacterial numbers across a full-scale membrane bioreactor (MBR) blackwater reuse system. Flow cytometry was used to quantify total and intact bacterial concentrations across the treatment train and during distribution of the recycled water. Membrane passage reduced bacterial numbers by up to 5-log units resulting in coliform-free permeate. A 2-log increase in bacterial cell concentration was subsequently observed after the granular activated carbon unit followed by a reduction in intact cells after chlorination, which corresponds to an overall intact bacteria removal of 3.4-log units. In the distribution network, the proportion of intact cells greatly depended on the free chlorine residual, with decreasing residual enabling regrowth. An initial target of 0.5 mg L-1 free chlorine ensured sufficient suppression of intact cells for up to 14 days (setting the time intervals for system flushes at times of low water usage). Bacterial regrowth was only observed when the free chlorine concentration was below 0.34 mg L-1. Such loss of residual chlorine mainly applied to distant points in the distribution network from the blackwater reuse treatment plant (BRTP). Flushing these network points for 5 min did not substantially reduce cell numbers. At points closer to the BRTP, on the other hand, flushing reduced cell numbers by up to 1.5-log units concomitant with a decreasing proportion of intact cells. Intact cell concentrations did not correlate with DOC, total nitrogen, or soluble reactive phosphate, but it was shown that dead biomass could be efficiently converted into new biomass within seven days.
Collapse
Affiliation(s)
- Rachel Whitton
- School of Water, Energy and Environment, Cranfield University, Cranfield, Bedfordshire MK43 0AL, United Kingdom
| | - Sarah Fane
- School of Water, Energy and Environment, Cranfield University, Cranfield, Bedfordshire MK43 0AL, United Kingdom
| | - Peter Jarvis
- School of Water, Energy and Environment, Cranfield University, Cranfield, Bedfordshire MK43 0AL, United Kingdom
| | - Martyn Tupper
- Thames Water Utilities Ltd, Clearwater Court, Vastern Road, Reading, Berkshire RG1 8DB, United Kingdom
| | - Marie Raffin
- Thames Water Utilities Ltd, Clearwater Court, Vastern Road, Reading, Berkshire RG1 8DB, United Kingdom
| | - Frédéric Coulon
- School of Water, Energy and Environment, Cranfield University, Cranfield, Bedfordshire MK43 0AL, United Kingdom
| | - Andreas Nocker
- School of Water, Energy and Environment, Cranfield University, Cranfield, Bedfordshire MK43 0AL, United Kingdom; IWW Water Centre, Moritzstraße 26, 45476 Mülheim an der Ruhr, Germany.
| |
Collapse
|
35
|
Douterelo I, Fish KE, Boxall JB. Succession of bacterial and fungal communities within biofilms of a chlorinated drinking water distribution system. WATER RESEARCH 2018; 141:74-85. [PMID: 29778067 DOI: 10.1016/j.watres.2018.04.058] [Citation(s) in RCA: 67] [Impact Index Per Article: 11.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2017] [Revised: 04/05/2018] [Accepted: 04/25/2018] [Indexed: 06/08/2023]
Abstract
Understanding the temporal dynamics of multi-species biofilms in Drinking Water Distribution Systems (DWDS) is essential to ensure safe, high quality water reaches consumers after it passes through these high surface area reactors. This research studied the succession characteristics of fungal and bacterial communities under controlled environmental conditions fully representative of operational DWDS. Microbial communities were observed to increase in complexity after one month of biofilm development but they did not reach stability after three months. Changes in cell numbers were faster at the start of biofilm formation and tended to decrease over time, despite the continuing changes in bacterial community composition. Fungal diversity was markedly less than bacterial diversity and had a lag in responding to temporal dynamics. A core-mixed community of bacteria including Pseudomonas, Massillia and Sphingomonas and the fungi Acremonium and Neocosmopora were present constantly and consistently in the biofilms over time and conditions studied. Monitoring and managing biofilms and such ubiquitous core microbial communities are key control strategies to ensuring the delivery of safe drinking water via the current ageing DWDS infrastructure.
Collapse
Affiliation(s)
- I Douterelo
- Pennine Water Group, Department of Civil and Structural Engineering, Mappin Street, University of Sheffield, Sheffield, S1 3JD, UK.
| | - K E Fish
- Pennine Water Group, Department of Civil and Structural Engineering, Mappin Street, University of Sheffield, Sheffield, S1 3JD, UK
| | - J B Boxall
- Pennine Water Group, Department of Civil and Structural Engineering, Mappin Street, University of Sheffield, Sheffield, S1 3JD, UK
| |
Collapse
|
36
|
Potgieter S, Pinto A, Sigudu M, du Preez H, Ncube E, Venter S. Long-term spatial and temporal microbial community dynamics in a large-scale drinking water distribution system with multiple disinfectant regimes. WATER RESEARCH 2018; 139:406-419. [PMID: 29673939 DOI: 10.1016/j.watres.2018.03.077] [Citation(s) in RCA: 72] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/25/2017] [Revised: 03/29/2018] [Accepted: 03/30/2018] [Indexed: 05/19/2023]
Abstract
Long-term spatial-temporal investigations of microbial dynamics in full-scale drinking water distribution systems are scarce. These investigations can reveal the process, infrastructure, and environmental factors that influence the microbial community, offering opportunities to re-think microbial management in drinking water systems. Often, these insights are missed or are unreliable in short-term studies, which are impacted by stochastic variabilities inherent to large full-scale systems. In this two-year study, we investigated the spatial and temporal dynamics of the microbial community in a large, full scale South African drinking water distribution system that uses three successive disinfection strategies (i.e. chlorination, chloramination and hypochlorination). Monthly bulk water samples were collected from the outlet of the treatment plant and from 17 points in the distribution system spanning nearly 150 km and the bacterial community composition was characterised by Illumina MiSeq sequencing of the V4 hypervariable region of the 16S rRNA gene. Like previous studies, Alpha- and Betaproteobacteria dominated the drinking water bacterial communities, with an increase in Betaproteobacteria post-chloramination. In contrast with previous reports, the observed richness, diversity, and evenness of the bacterial communities were higher in the winter months as opposed to the summer months in this study. In addition to temperature effects, the seasonal variations were also likely to be influenced by changes in average water age in the distribution system and corresponding changes in disinfectant residual concentrations. Spatial dynamics of the bacterial communities indicated distance decay, with bacterial communities becoming increasingly dissimilar with increasing distance between sampling locations. These spatial effects dampened the temporal changes in the bulk water community and were the dominant factor when considering the entire distribution system. However, temporal variations were consistently stronger as compared to spatial changes at individual sampling locations and demonstrated seasonality. This study emphasises the need for long-term studies to comprehensively understand the temporal patterns that would otherwise be missed in short-term investigations. Furthermore, systematic long-term investigations are particularly critical towards determining the impact of changes in source water quality, environmental conditions, and process operations on the changes in microbial community composition in the drinking water distribution system.
Collapse
Affiliation(s)
- Sarah Potgieter
- Department of Microbiology and Plant Pathology, University of Pretoria, Pretoria, South Africa
| | - Ameet Pinto
- Department of Civil and Environmental Engineering, Northeastern University, Boston, USA
| | | | - Hein du Preez
- Scientific Services, Rand Water, Vereeniging, South Africa
| | - Esper Ncube
- Scientific Services, Rand Water, Vereeniging, South Africa
| | - Stephanus Venter
- Department of Microbiology and Plant Pathology, University of Pretoria, Pretoria, South Africa.
| |
Collapse
|
37
|
Towhid ST. Microbial Interaction as a Determinant of the Quality of Supply Drinking Water: A Conceptual Analysis. Front Public Health 2018; 6:184. [PMID: 29998093 PMCID: PMC6028747 DOI: 10.3389/fpubh.2018.00184] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2018] [Accepted: 06/08/2018] [Indexed: 11/13/2022] Open
Abstract
This conceptual analysis elucidates the microbial interaction inside municipal distribution pipes, subsequent deterioration in the quality of the supply water, and its impacts on public health. Literature review involved a total of 21 original reports on microbiological events inside the water distribution system were studied, summarizing the current knowledge about the build-up of microbes in treated municipal water at various points of the distribution system. Next, original reports from the microbiological analysis of supply water from Bangladesh were collected to enlist the types of bacteria found growing actively. A schematic diagram of microbial interaction among the genera was constructed with respect to the physical, chemical, and microbiological quality of the supply water. Finally latest guidelines and expert opinions from public health authorities around the world are reviewed to keep up with using cutting-edge molecular technology to ensure safe and good quality drinking water for municipal supply.
Collapse
Affiliation(s)
- Syeda T Towhid
- Department of Microbiology, Jagannath University, Dhaka, Bangladesh
| |
Collapse
|
38
|
Hou L, Zhou Q, Wu Q, Gu Q, Sun M, Zhang J. Spatiotemporal changes in bacterial community and microbial activity in a full-scale drinking water treatment plant. THE SCIENCE OF THE TOTAL ENVIRONMENT 2018; 625:449-459. [PMID: 29291559 DOI: 10.1016/j.scitotenv.2017.12.301] [Citation(s) in RCA: 57] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/31/2017] [Revised: 12/23/2017] [Accepted: 12/25/2017] [Indexed: 06/07/2023]
Abstract
To gain insight into the bacterial dynamics present in drinking water treatment (DWT) systems, the microbial community and activity in a full-scale DWT plant (DWTP) in Guangzhou, South China, were investigated using Illumina Hiseq sequencing analyses combined with cultivation-based techniques during the wet and dry seasons. Illumina sequencing analysis of 16S rRNA genes revealed a large shift in the proportion of Actinobacteria, Proteobacteria and Firmicutes during the treatment process, with the proportion of Actinobacteria decreased sharply, whereas that of Proteobacteria and Firmicutes increased and predominated in treated water. Both microbial activity and bacterial diversity during the treatment process showed obvious spatial variation, with higher levels observed during the dry season and lower levels during the wet season. Clustering analysis and principal component analysis indicated dramatic shifts in the bacterial community after chlorination, suggesting that chlorination was highly effective at influencing the bacterial community. The bacterial community structure of finished water primarily comprised Pseudomonas, Citrobacter, and Acinetobacter, and interestingly showed high similarity to biofilms on granular activated carbon. Additionally, the abundance of bacterial communities was relatively stable in finished water and did not change with the season. A large number of unique operational taxonomic units were shared during treatment steps, indicating the presence of a diverse core microbiome throughout the treatment process. Opportunistic pathogens, including Pseudomonas, Acinetobacter, Citrobacter, Mycobacterium, Salmonella, Staphylococcus, Legionella, Streptococcus and Enterococcus, were detected in water including finished water, suggesting a potential threat to drinking-water safety. We also detected bacteria isolated from each treatment step using the pure-culture method. In particular, two isolates, identified as Mycobacterium sp. and Blastococcus sp., which belong to the phylum Actinobacteria, were obtained from finished water during the dry season. Together, these results provided evidence of spatial and temporal variations in DWTPs and contributed to the beneficial manipulation of the drinking water microbiome.
Collapse
Affiliation(s)
- Luanfeng Hou
- School of Environment and Energy, South China University of Technology, Guangzhou 510006, PR China; Guangdong Institute of Microbiology, State Key Laboratory of Applied Microbiology Southern China, Guangdong Provincial Key Laboratory of Microbial Culture Collection and Application, Guangdong Open Laboratory of Applied Microbiology, Guangzhou 510070, PR China
| | - Qin Zhou
- School of Environment and Energy, South China University of Technology, Guangzhou 510006, PR China
| | - Qingping Wu
- Guangdong Institute of Microbiology, State Key Laboratory of Applied Microbiology Southern China, Guangdong Provincial Key Laboratory of Microbial Culture Collection and Application, Guangdong Open Laboratory of Applied Microbiology, Guangzhou 510070, PR China
| | - Qihui Gu
- Guangdong Institute of Microbiology, State Key Laboratory of Applied Microbiology Southern China, Guangdong Provincial Key Laboratory of Microbial Culture Collection and Application, Guangdong Open Laboratory of Applied Microbiology, Guangzhou 510070, PR China
| | - Ming Sun
- Guangdong Institute of Microbiology, State Key Laboratory of Applied Microbiology Southern China, Guangdong Provincial Key Laboratory of Microbial Culture Collection and Application, Guangdong Open Laboratory of Applied Microbiology, Guangzhou 510070, PR China; Guangzhou Institute of Chemistry, Chinese Academy of Sciences, Guangzhou 510650, PR China
| | - Jumei Zhang
- Guangdong Institute of Microbiology, State Key Laboratory of Applied Microbiology Southern China, Guangdong Provincial Key Laboratory of Microbial Culture Collection and Application, Guangdong Open Laboratory of Applied Microbiology, Guangzhou 510070, PR China.
| |
Collapse
|
39
|
Nescerecka A, Juhna T, Hammes F. Identifying the underlying causes of biological instability in a full-scale drinking water supply system. WATER RESEARCH 2018; 135:11-21. [PMID: 29448079 DOI: 10.1016/j.watres.2018.02.006] [Citation(s) in RCA: 48] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/07/2017] [Revised: 02/02/2018] [Accepted: 02/05/2018] [Indexed: 06/08/2023]
Abstract
Changes in bacterial concentration and composition in drinking water during distribution are often attributed to biological (in)stability. Here we assessed temporal biological stability in a full-scale distribution network (DN) supplied with different types of source water: treated and chlorinated surface water and chlorinated groundwater produced at three water treatment plants (WTP). Monitoring was performed weekly during 12 months in two locations in the DN. Flow cytometric total and intact cell concentration (ICC) measurements showed considerable seasonal fluctuations, which were different for two locations. ICC varied between 0.1-3.75 × 105 cells mL-1 and 0.69-4.37 × 105 cells mL-1 at two locations respectively, with ICC increases attributed to temperature-dependent bacterial growth during distribution. Chlorinated water from the different WTP was further analysed with a modified growth potential method, identifying primary and secondary growth limiting compounds. It was observed that bacterial growth in the surface water sample after chlorination was primarily inhibited by phosphorus limitation and secondly by organic carbon limitation, while carbon was limiting in the chlorinated groundwater samples. However, the ratio of available nutrients changed during distribution, and together with disinfection residual decay, this resulted in higher bacterial growth potential detected in the DN than at the WTP. In this study, bacterial growth was found to be higher (i) at higher water temperatures, (ii) in samples with lower chlorine residuals and (iii) in samples with less nutrient (carbon, phosphorus, nitrogen, iron) limitation, while this was significantly different between the samples of different origin. Thus drinking water microbiological quality and biological stability could change during different seasons, and the extent of these changes depends on water temperature, the water source and treatment. Furthermore, differences in primary growth limiting nutrients in different water sources could contribute to biological instability in the network, where mixing occurs.
Collapse
Affiliation(s)
- Alina Nescerecka
- Riga Technical University, Kipsalas str. 6A, LV-1048 Riga, Latvia; Eawag, Swiss Federal Institute of Aquatic Science and Technology, Überlandstrasse 133, CH-8600 Dübendorf, Switzerland.
| | - Talis Juhna
- Riga Technical University, Kipsalas str. 6A, LV-1048 Riga, Latvia
| | - Frederik Hammes
- Eawag, Swiss Federal Institute of Aquatic Science and Technology, Überlandstrasse 133, CH-8600 Dübendorf, Switzerland
| |
Collapse
|
40
|
Zlatanović L, van der Hoek JP, Vreeburg JHG. An experimental study on the influence of water stagnation and temperature change on water quality in a full-scale domestic drinking water system. WATER RESEARCH 2017; 123:761-772. [PMID: 28732329 DOI: 10.1016/j.watres.2017.07.019] [Citation(s) in RCA: 72] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/05/2016] [Revised: 07/02/2017] [Accepted: 07/09/2017] [Indexed: 06/07/2023]
Abstract
The drinking water quality changes during the transport through distribution systems. Domestic drinking water systems (DDWSs), which include the plumbing between the water meter and consumer's taps, are the most critical points in which water quality may be affected. In distribution networks, the drinking water temperature and water residence time are regarded as indicators of the drinking water quality. This paper describes an experimental research on the influence of stagnation time and temperature change on drinking water quality in a full-scale DDWS. Two sets of stagnation experiments, during winter and summer months, with various stagnation intervals (up to 168 h of stagnation) were carried out. Water and biofilms were sampled at two different taps, a kitchen and a shower tap. Results from this study indicate that temperature and water stagnation affect both chemical and microbial quality in DDWSs, whereas microbial parameters in stagnant water appear to be driven by the temperature of fresh water. Biofilm formed in the shower pipe contained more total and intact cells than the kitchen pipe biofilm. Alphaproteobacteria were found to dominate in the shower biofilm (78% of all Proteobacteria), while in the kitchen tap biofilm Alphaproteobacteria, Betaproteobacteria and Gammaproteobacteria were evenly distributed.
Collapse
Affiliation(s)
- Lj Zlatanović
- Delft University of Technology, Department of Water Management, Delft, The Netherlands.
| | - J P van der Hoek
- Delft University of Technology, Department of Water Management, Delft, The Netherlands; Waternet, Strategic Centre, Amsterdam, The Netherlands.
| | - J H G Vreeburg
- Wageningen University, Sub- Department of Environmental Technology, Wageningen, The Netherlands; KWR Watercycle Research Institute, Nieuwegein, The Netherlands.
| |
Collapse
|
41
|
Besmer MD, Sigrist JA, Props R, Buysschaert B, Mao G, Boon N, Hammes F. Laboratory-Scale Simulation and Real-Time Tracking of a Microbial Contamination Event and Subsequent Shock-Chlorination in Drinking Water. Front Microbiol 2017; 8:1900. [PMID: 29085343 PMCID: PMC5649192 DOI: 10.3389/fmicb.2017.01900] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2017] [Accepted: 09/15/2017] [Indexed: 12/14/2022] Open
Abstract
Rapid contamination of drinking water in distribution and storage systems can occur due to pressure drop, backflow, cross-connections, accidents, and bio-terrorism. Small volumes of a concentrated contaminant (e.g., wastewater) can contaminate large volumes of water in a very short time with potentially severe negative health impacts. The technical limitations of conventional, cultivation-based microbial detection methods neither allow for timely detection of such contaminations, nor for the real-time monitoring of subsequent emergency remediation measures (e.g., shock-chlorination). Here we applied a newly developed continuous, ultra high-frequency flow cytometry approach to track a rapid pollution event and subsequent disinfection of drinking water in an 80-min laboratory scale simulation. We quantified total (TCC) and intact (ICC) cell concentrations as well as flow cytometric fingerprints in parallel in real-time with two different staining methods. The ingress of wastewater was detectable almost immediately (i.e., after 0.6% volume change), significantly changing TCC, ICC, and the flow cytometric fingerprint. Shock chlorination was rapid and detected in real time, causing membrane damage in the vast majority of bacteria (i.e., drop of ICC from more than 380 cells μl-1 to less than 30 cells μl-1 within 4 min). Both of these effects as well as the final wash-in of fresh tap water followed calculated predictions well. Detailed and highly quantitative tracking of microbial dynamics at very short time scales and for different characteristics (e.g., concentration, membrane integrity) is feasible. This opens up multiple possibilities for targeted investigation of a myriad of bacterial short-term dynamics (e.g., disinfection, growth, detachment, operational changes) both in laboratory-scale research and full-scale system investigations in practice.
Collapse
Affiliation(s)
- Michael D Besmer
- Drinking Water Microbiology Group, Department of Environmental Microbiology, Eawag, Swiss Federal Institute of Aquatic Science and Technology, Dübendorf, Switzerland.,Department of Environmental Systems Science, Institute of Biogeochemistry and Pollutant Dynamics, Zürich, Switzerland
| | - Jürg A Sigrist
- Drinking Water Microbiology Group, Department of Environmental Microbiology, Eawag, Swiss Federal Institute of Aquatic Science and Technology, Dübendorf, Switzerland
| | - Ruben Props
- Center for Microbial Ecology and Technology, Ghent University, Ghent, Belgium
| | | | - Guannan Mao
- Drinking Water Microbiology Group, Department of Environmental Microbiology, Eawag, Swiss Federal Institute of Aquatic Science and Technology, Dübendorf, Switzerland.,Key Laboratory of Pollution Processes and Environmental Criteria (Ministry of Education), Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, Tianjin, China
| | - Nico Boon
- Center for Microbial Ecology and Technology, Ghent University, Ghent, Belgium
| | - Frederik Hammes
- Drinking Water Microbiology Group, Department of Environmental Microbiology, Eawag, Swiss Federal Institute of Aquatic Science and Technology, Dübendorf, Switzerland
| |
Collapse
|
42
|
Van Nevel S, Koetzsch S, Proctor CR, Besmer MD, Prest EI, Vrouwenvelder JS, Knezev A, Boon N, Hammes F. Flow cytometric bacterial cell counts challenge conventional heterotrophic plate counts for routine microbiological drinking water monitoring. WATER RESEARCH 2017; 113:191-206. [PMID: 28214393 DOI: 10.1016/j.watres.2017.01.065] [Citation(s) in RCA: 118] [Impact Index Per Article: 16.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2016] [Revised: 01/30/2017] [Accepted: 01/31/2017] [Indexed: 06/06/2023]
Abstract
Drinking water utilities and researchers continue to rely on the century-old heterotrophic plate counts (HPC) method for routine assessment of general microbiological water quality. Bacterial cell counting with flow cytometry (FCM) is one of a number of alternative methods that challenge this status quo and provide an opportunity for improved water quality monitoring. After more than a decade of application in drinking water research, FCM methodology is optimised and established for routine application, supported by a considerable amount of data from multiple full-scale studies. Bacterial cell concentrations obtained by FCM enable quantification of the entire bacterial community instead of the minute fraction of cultivable bacteria detected with HPC (typically < 1% of all bacteria). FCM measurements are reproducible with relative standard deviations below 3% and can be available within 15 min of samples arriving in the laboratory. High throughput sample processing and complete automation are feasible and FCM analysis is arguably less expensive than HPC when measuring more than 15 water samples per day, depending on the laboratory and selected staining procedure(s). Moreover, many studies have shown FCM total (TCC) and intact (ICC) cell concentrations to be reliable and robust process variables, responsive to changes in the bacterial abundance and relevant for characterising and monitoring drinking water treatment and distribution systems. The purpose of this critical review is to initiate a constructive discussion on whether FCM could replace HPC in routine water quality monitoring. We argue that FCM provides a faster, more descriptive and more representative quantification of bacterial abundance in drinking water.
Collapse
Affiliation(s)
- S Van Nevel
- Center for Microbial Ecology and Technology (CMET), Ghent University, Coupure Links 653, B-9000, Gent, Belgium
| | - S Koetzsch
- Eawag, Swiss Federal Institute of Aquatic Science and Technology, Überlandstrasse 133, CH-8600, Dübendorf, Switzerland
| | - C R Proctor
- Eawag, Swiss Federal Institute of Aquatic Science and Technology, Überlandstrasse 133, CH-8600, Dübendorf, Switzerland; Department of Environmental Systems Science, Institute of Biogeochemistry and Pollutant Dynamics, ETH Zürich, Zürich, Switzerland
| | - M D Besmer
- Eawag, Swiss Federal Institute of Aquatic Science and Technology, Überlandstrasse 133, CH-8600, Dübendorf, Switzerland
| | - E I Prest
- Department of Biotechnology, Faculty of Applied Sciences, Delft University of Technology, Van der Maasweg 9, 2629 HZ, Delft, The Netherlands
| | - J S Vrouwenvelder
- Department of Biotechnology, Faculty of Applied Sciences, Delft University of Technology, Van der Maasweg 9, 2629 HZ, Delft, The Netherlands; Wetsus, Centre of Excellence for Sustainable Water Technology, Oostergoweg 9, 8911 MA, Leeuwarden, The Netherlands; King Abdullah University of Science and Technology (KAUST), Water Desalination and Reuse Center (WDRC), Division of Biological and Environmental Science and Engineering (BESE), Thuwal, 23955-6900, Saudi Arabia
| | - A Knezev
- Het Waterlaboratorium, J.W. Lucasweg 2, 2031 BE, Haarlem, The Netherlands
| | - N Boon
- Center for Microbial Ecology and Technology (CMET), Ghent University, Coupure Links 653, B-9000, Gent, Belgium
| | - F Hammes
- Eawag, Swiss Federal Institute of Aquatic Science and Technology, Überlandstrasse 133, CH-8600, Dübendorf, Switzerland.
| |
Collapse
|
43
|
Besmer MD, Epting J, Page RM, Sigrist JA, Huggenberger P, Hammes F. Online flow cytometry reveals microbial dynamics influenced by concurrent natural and operational events in groundwater used for drinking water treatment. Sci Rep 2016; 6:38462. [PMID: 27924920 PMCID: PMC5141442 DOI: 10.1038/srep38462] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2016] [Accepted: 11/09/2016] [Indexed: 01/21/2023] Open
Abstract
Detailed measurements of physical, chemical and biological dynamics in groundwater are key to understanding the important processes in place and their influence on water quality – particularly when used for drinking water. Measuring temporal bacterial dynamics at high frequency is challenging due to the limitations in automation of sampling and detection of the conventional, cultivation-based microbial methods. In this study, fully automated online flow cytometry was applied in a groundwater system for the first time in order to monitor microbial dynamics in a groundwater extraction well. Measurements of bacterial concentrations every 15 minutes during 14 days revealed both aperiodic and periodic dynamics that could not be detected previously, resulting in total cell concentration (TCC) fluctuations between 120 and 280 cells μL−1. The aperiodic dynamic was linked to river water contamination following precipitation events, while the (diurnal) periodic dynamic was attributed to changes in hydrological conditions as a consequence of intermittent groundwater extraction. Based on the high number of measurements, the two patterns could be disentangled and quantified separately. This study i) increases the understanding of system performance, ii) helps to optimize monitoring strategies, and iii) opens the possibility for more sophisticated (quantitative) microbial risk assessment of drinking water treatment systems.
Collapse
Affiliation(s)
- Michael D Besmer
- Department of Environmental Microbiology, Eawag, Swiss Federal Institute of Aquatic Science and Technology, Dübendorf, Switzerland.,Department of Environmental Systems Science, Institute of Biogeochemistry and Pollutant Dynamics, ETH Zürich, Zürich, Switzerland
| | - Jannis Epting
- Applied and Environmental Geology, Department of Environmental Sciences, University of Basel, Basel, Switzerland
| | - Rebecca M Page
- Applied and Environmental Geology, Department of Environmental Sciences, University of Basel, Basel, Switzerland.,Endress+Hauser (Schweiz) AG, Kägenstrasse 2, 4153 Reinach, Switzerland
| | - Jürg A Sigrist
- Department of Environmental Microbiology, Eawag, Swiss Federal Institute of Aquatic Science and Technology, Dübendorf, Switzerland
| | - Peter Huggenberger
- Applied and Environmental Geology, Department of Environmental Sciences, University of Basel, Basel, Switzerland
| | - Frederik Hammes
- Department of Environmental Microbiology, Eawag, Swiss Federal Institute of Aquatic Science and Technology, Dübendorf, Switzerland
| |
Collapse
|