1
|
Feigel ED, Bird MB, Koltun KJ, Lovalekar M, Forse JN, Gage CR, Steele EJ, Kargl CK, Martin BJ, Bannister A, Cruz AV, Doyle TLA, Friedl KE, Nindl BC. Allostatic Load Is Associated with Overuse Musculoskeletal Injury during US Marine Corps Officer Candidates School. Med Sci Sports Exerc 2024; 56:2220-2229. [PMID: 38934495 DOI: 10.1249/mss.0000000000003507] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/28/2024]
Abstract
INTRODUCTION Overuse musculoskeletal injuries (MSKI) remain a significant medical challenge in military personnel undergoing military training courses; further understanding of the biological process leading to overuse MSKI development and biological signatures for injury risk are warranted. The purpose of this study was to determine the association between overuse MSKI occurrence and physiological characteristics of allostatic load characterized as maladaptive biological responses to chronic stress measured by wearable devices in US Marine Corps officer candidates during a 10-wk training course. METHODS Devices recorded energy expenditure (EE), daytime heart rate (HR), sleeping HR, and sleep architecture (time and percentage of deep, light, rapid eye movement sleep, awake time, total sleep). Flux was calculated as the raw or absolute difference in the average value for that day or night and the day or night beforehand. Linear mixed-effect model analysis accounting for cardiorespiratory fitness assessed the association between overuse MSKI occurrence and device metrics ( α = 0.05). RESULTS Sixty-nine participants (23 females) were included. Twenty-one participants (eight females) sustained overuse MSKI. Overuse MSKI occurrence in male participants was positively associated with daytime HR ( β = 5.316, P = 0.008), sleeping HR ( β = 2.708, P = 0.032), relative EE ( β = 8.968, P = 0.001), absolute flux in relative EE ( β = 2.994, P = 0.002), absolute EE ( β = 626.830, P = 0.001), and absolute flux in absolute EE ( β = 204.062, P = 0.004). Overuse MSKI occurrence in female participants was positively associated with relative EE ( β = 5.955, P = 0.026), deep sleep time ( β = 0.664, P < 0.001), and percent deep sleep ( β = 12.564, P < 0.001) and negatively associated with absolute flux in sleeping HR ( β = -0.660, P = 0.009). CONCLUSIONS Overuse MSKI occurrences were associated with physiological characteristics of allostatic load, including chronically elevated HR and EE and greater time in restorative sleep stages, which may serve as biological signatures for overuse MSKI risk.
Collapse
Affiliation(s)
- Evan D Feigel
- Neuromuscular Research Laboratory/Warrior Human Performance Research Center, University of Pittsburgh, Pittsburgh, PA
| | - Matthew B Bird
- Neuromuscular Research Laboratory/Warrior Human Performance Research Center, University of Pittsburgh, Pittsburgh, PA
| | - Kristen J Koltun
- Neuromuscular Research Laboratory/Warrior Human Performance Research Center, University of Pittsburgh, Pittsburgh, PA
| | - Mita Lovalekar
- Neuromuscular Research Laboratory/Warrior Human Performance Research Center, University of Pittsburgh, Pittsburgh, PA
| | - Jennifer N Forse
- Neuromuscular Research Laboratory/Warrior Human Performance Research Center, University of Pittsburgh, Pittsburgh, PA
| | - Catherine R Gage
- Neuromuscular Research Laboratory/Warrior Human Performance Research Center, University of Pittsburgh, Pittsburgh, PA
| | - Elizabeth J Steele
- Neuromuscular Research Laboratory/Warrior Human Performance Research Center, University of Pittsburgh, Pittsburgh, PA
| | - Christopher K Kargl
- Neuromuscular Research Laboratory/Warrior Human Performance Research Center, University of Pittsburgh, Pittsburgh, PA
| | - Brian J Martin
- Neuromuscular Research Laboratory/Warrior Human Performance Research Center, University of Pittsburgh, Pittsburgh, PA
| | | | | | | | - Karl E Friedl
- US Army Research Institute of Environmental Medicine, Natick, MA
| | - Bradley C Nindl
- Neuromuscular Research Laboratory/Warrior Human Performance Research Center, University of Pittsburgh, Pittsburgh, PA
| |
Collapse
|
2
|
Chen CH, Lai F, Huang LY, Guo YLL. Short- and medium-term cumulative effects of traffic-related air pollution on resting heart rate in the elderly: A wearable device study. ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY 2024; 285:117140. [PMID: 39368154 DOI: 10.1016/j.ecoenv.2024.117140] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2024] [Revised: 09/28/2024] [Accepted: 09/28/2024] [Indexed: 10/07/2024]
Abstract
BACKGROUND Epidemiological evidence regarding the association between air pollution and resting heart rate (RHR), a predictor of cardiovascular disease and mortality, is limited and inconsistent. OBJECTIVES We used wearable devices and time-series analysis to assess the exposure-response relationship over an extended lag period. METHODS Ninety-seven elderly individuals (>65 years) from the Taipei Basin participated from May to November 2020 and wore Garmin® smartwatches continuously until the end of 2021 for heart rate monitoring. RHR was defined as the daily average of the lowest 30-min heart rate. Air pollution exposure data, covering lag periods from 0 to 60 days, were obtained from nearby monitoring stations. We used distributed lag non-linear models and linear mixed-effect models to assess cumulative effects of air pollution. Principal component analysis was utilized to explore underlying patterns in air pollution exposure, and subgroup analyses with interaction terms were conducted to explore the modification effects of individual factors. RESULTS After adjusting for co-pollutants in the models, an interquartile range increase of 0.18 ppm in carbon monoxide (CO) was consistently associated with increased RHR across lag periods of 0-1 day (0.31, 95 % confidence interval [CI]: 0.24-0.38), 0-7 days (0.68, 95 % CI: 0.57-0.79), and 0-50 days (1.02, 95 % CI: 0.82-1.21). Principal component analysis identified two factors, one primarily influenced by CO and nitrogen dioxide (NO2), indicative of traffic sources. Increases in the varimax-rotated traffic-related score were correlated with higher RHR over 0-1 day (0.36, 95 % CI: 0.25-0.47), 0-7 days (0.62, 95 % CI: 0.46-0.77), and 0-50 days (1.27, 95 % CI: 0.87-1.67) lag periods. Over a 0-7 day lag, RHR responses to traffic pollution were intensified by higher temperatures (β = 0.80 vs. 0.29; interaction p-value [P_int] = 0.011). Males (β = 0.66 vs. 0.60; P_int < 0.0001), hypertensive individuals (β = 0.85 vs. 0.45; P_int = 0.028), diabetics (β = 0.96 vs. 0.52; P_int = 0.042), and those with lower physical activity (β = 0.70 vs. 0.54; P_int < 0.0001) also exhibited stronger responses. Over a 0-50 day lag, males (β = 0.99 vs. 0.96; P_int < 0.0001), diabetics (β = 1.66 vs. 0.69; P_int < 0.0001), individuals with lower physical activity (β = 1.49 vs. 0.47; P_int = 0.0006), and those with fewer steps on lag day 1 (β = 1.17 vs. 0.71; P_int = 0.029) showed amplified responses. CONCLUSIONS Prolonged exposure to traffic-related air pollution results in cumulative cardiovascular risks, persisting for up to 50 days. These effects are more pronounced on warmer days and in individuals with chronic conditions or inactive lifestyles.
Collapse
Affiliation(s)
- Chi-Hsien Chen
- Department of Environmental and Occupational Medicine, National Taiwan University (NTU) College of medicine and NTU Hospital, Taipei, Taiwan
| | - Feipei Lai
- Department of Computer Science and Information Engineering, National Taiwan University, Taipei, Taiwan
| | - Li-Ying Huang
- School of Medicine, College of Medicine, Fu Jen Catholic University, New Taipei City, Taiwan; Division of Endocrinology and Metabolism, Department of Internal Medicine, and Department of Medical Education, Fu Jen Catholic University Hospital, New Taipei City, Taiwan
| | - Yue-Liang Leon Guo
- Department of Environmental and Occupational Medicine, National Taiwan University (NTU) College of medicine and NTU Hospital, Taipei, Taiwan; Institute of Environmental and Occupational Health Sciences, National Taiwan University, Taipei 100, Taiwan; National Institute of Environmental Sciences, National Health Research Institutes, No. 35, Keyan Rd., Zhunan Township, Miaoli County, Taiwan.
| |
Collapse
|
3
|
Singh S, Bennett MR, Chen C, Shin S, Ghanbari H, Nelson BW. Impact of Skin Pigmentation on Pulse Oximetry Blood Oxygenation and Wearable Pulse Rate Accuracy: Systematic Review and Meta-Analysis. J Med Internet Res 2024; 26:e62769. [PMID: 39388258 PMCID: PMC11502980 DOI: 10.2196/62769] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2024] [Revised: 07/25/2024] [Accepted: 08/16/2024] [Indexed: 10/12/2024] Open
Abstract
BACKGROUND Photoplethysmography (PPG) is a technology routinely used in clinical practice to assess blood oxygenation (SpO2) and pulse rate (PR). Skin pigmentation may influence accuracy, leading to health outcomes disparities. OBJECTIVE This systematic review and meta-analysis primarily aimed to evaluate the accuracy of PPG-derived SpO2 and PR by skin pigmentation. Secondarily, we aimed to evaluate statistical biases and the clinical relevance of PPG-derived SpO2 and PR according to skin pigmentation. METHODS We identified 23 pulse oximetry studies (n=59,684; 197,353 paired SpO2-arterial blood observations) and 4 wearable PR studies (n=176; 140,771 paired PPG-electrocardiography observations). We evaluated accuracy according to skin pigmentation group by comparing SpO2 accuracy root-mean-square values to the regulatory threshold of 3% and PR 95% limits of agreement values to +5 or -5 beats per minute (bpm), according to the standards of the American National Standards Institute, Association for the Advancement of Medical Instrumentation, and the International Electrotechnical Commission. We evaluated biases and clinical relevance using mean bias and 95% CI. RESULTS For SpO2, accuracy root-mean-square values were 3.96%, 4.71%, and 4.15%, and pooled mean biases were 0.70% (95% CI 0.17%-1.22%), 0.27% (95% CI -0.64% to 1.19%), and 1.27% (95% CI 0.58%-1.95%) for light, medium, and dark pigmentation, respectively. For PR, 95% limits of agreement values were from -16.02 to 13.54, from -18.62 to 16.84, and from -33.69 to 32.54, and pooled mean biases were -1.24 (95% CI -5.31 to 2.83) bpm, -0.89 (95% CI -3.70 to 1.93) bpm, and -0.57 (95% CI -9.44 to 8.29) bpm for light, medium, and dark pigmentation, respectively. CONCLUSIONS SpO2 and PR measurements may be inaccurate across all skin pigmentation groups, breaching U.S. Food and Drug Administration guidance and industry standard thresholds. Pulse oximeters significantly overestimate SpO2 for both light and dark skin pigmentation, but this overestimation may not be clinically relevant. PRs obtained from wearables exhibit no statistically or clinically significant bias based on skin pigmentation.
Collapse
Affiliation(s)
- Sanidhya Singh
- University of Michigan Medical School, Ann Arbor, MI, United States
| | | | - Chen Chen
- Verily Life Sciences LLC, South San Francisco, CA, United States
| | - Sooyoon Shin
- Verily Life Sciences LLC, South San Francisco, CA, United States
| | - Hamid Ghanbari
- University of Michigan Medical School, Ann Arbor, MI, United States
| | - Benjamin W Nelson
- Verily Life Sciences LLC, South San Francisco, CA, United States
- Division of Digital Psychiatry, Department of Psychiatry, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, United States
| |
Collapse
|
4
|
Hu X, Sgherza TR, Nothrup JB, Fresco DM, Naragon-Gainey K, Bylsma LM. From lab to life: Evaluating the reliability and validity of psychophysiological data from wearable devices in laboratory and ambulatory settings. Behav Res Methods 2024; 56:1-20. [PMID: 38528248 DOI: 10.3758/s13428-024-02387-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/02/2024] [Indexed: 03/27/2024]
Abstract
Despite the increasing popularity of ambulatory assessment, the reliability and validity of psychophysiological signals from wearable devices is unproven in daily life settings. We evaluated the reliability and validity of physiological signals (electrocardiogram, ECG; photoplethysmography, PPG; electrodermal activity, EDA) collected from two wearable devices (Movisens EcgMove4 and Empatica E4) in the lab (N = 67) and daily life (N = 20) among adults aged 18-64 with Mindware as the laboratory gold standard. Results revealed that both wearable devices' valid data rates in daily life were lower than in the laboratory (Movisens ECG 82.94 vs. 93.10%, Empatica PPG 8.79 vs. 26.14%, and Empatica EDA 41.16 vs. 42.67%, respectively). The poor valid data rates of Empatica PPG signals in the laboratory could be partially attributed to participants' hand movements (r = - .27, p = .03). In laboratory settings, heart rate (HR) derived from both wearable devices exhibited higher concurrent validity than heart rate variability (HRV) metrics (ICCs 0.98-1.00 vs. 0.75-0.97). The number of skin conductance responses (SCRs) derived from Empatica showed higher concurrent validity than skin conductance level (SCL, ICCs 0.38 vs. 0.09). Movisens EcgMove4 provided more reliable and valid HRV measurements than Empatica E4 in both laboratory (split-half reliability: 0.95-0.99 vs. 0.85-0.98; concurrent validity: 0.95-1.00 vs. 0.75-0.98; valid data rate: 93.10 vs. 26.14%) and ambulatory settings (split-half reliability: 0.99-1.00 vs. 0.89-0.98; valid data rate: 82.94 vs. 8.79%). Although the reliability and validity of wearable devices are improving, findings suggest researchers should select devices that yield consistently robust and valid data for their measures of interest.
Collapse
Affiliation(s)
- Xin Hu
- Department of Psychiatry, University of Pittsburgh School of Medicine, Pittsburgh, PA, USA
| | - Tanika R Sgherza
- School of Psychological Science, University of Western Australia, Perth, Australia
| | - Jessie B Nothrup
- Department of Psychiatry, University of Pittsburgh School of Medicine, Pittsburgh, PA, USA
| | - David M Fresco
- Department of Psychiatry, University of Michigan, Ann Arbor, MI, USA
| | | | - Lauren M Bylsma
- Department of Psychiatry, University of Pittsburgh School of Medicine, Pittsburgh, PA, USA.
- Department of Psychology, University of Pittsburgh, Pittsburgh, PA, USA.
| |
Collapse
|
5
|
Jacko T, Bartsch J, von Diecken C, Ueberschär O. Validity of Current Smartwatches for Triathlon Training: How Accurate Are Heart Rate, Distance, and Swimming Readings? SENSORS (BASEL, SWITZERLAND) 2024; 24:4675. [PMID: 39066072 PMCID: PMC11281193 DOI: 10.3390/s24144675] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2024] [Revised: 07/11/2024] [Accepted: 07/16/2024] [Indexed: 07/28/2024]
Abstract
Smartwatches are one of the most relevant fitness trends of the past two decades, and they collect increasing amounts of health and movement data. The accuracy of these data may be questionable and requires further investigation. Therefore, the aim of the present study is to validate smartwatches for use in triathlon training. Ten different smartwatches were tested for accuracy in measuring heart rates, distances (via global navigation satellite systems, GNSSs), swim stroke rates and the number of swim laps in a 50 m Olympic-size pool. The optical heart rate measurement function of each smartwatch was compared to that of a chest strap. Thirty participants (15 females, 15 males) ran five 3 min intervals on a motorised treadmill to evaluate the accuracy of the heart rate measurements. Moreover, for each smartwatch, running and cycling distance tracking was tested over six runs of 4000 m on a 400 m tartan stadium track, six hilly outdoor runs over 3.4 km, and four repetitions of a 36.8 km road bike course, respectively. Three swimming protocols ranging from 200 m to 400 m were performed in triplicate in a 50 m Olympic-size pool, evaluating the tracked distance and the detected number of strokes. The mean absolute percentage errors (MAPEs) for the average heart rate measurements varied between 3.1% and 8.3%, with the coefficient of determination ranging from 0.22 to 0.79. MAPE results ranged from 0.8% to 12.1% for the 4000 m run on the 400 m track, from 0.2% to 7.5% for the 3.4 km outdoor run, and from 0.0% to 4.2% for the 36.8 km bike ride. For the swimming tests, in contrast, the deviations from the true distance varied greatly, starting at a 0.0% MAPE for the 400 m freestyle and reaching 91.7% for the 200 m medley with style changes every 25 m. In summary, for some of the smartwatches, the measurement results deviated substantially from the true values. Measurements taken while road cycling over longer distances with only a few curves were in relative terms more accurate than those taken during outdoor runs and even more accurate than those taken on the 400 m track. In the swimming exercises, the accuracy of the measured distances was severely deteriorated by the medley changes among the majority of the smartwatches. Altogether, the results of this study should help in assessing the accuracy and thus the suitability of smartwatches for general triathlon training.
Collapse
Affiliation(s)
- Tobias Jacko
- Department for Health Sciences, Medicine and Research, Faculty of Health and Medicine, Danube University Krems, 3500 Krems an der Donau, Austria;
| | - Julia Bartsch
- Department of Engineering and Industrial Design, Magdeburg-Stendal University of Applied Sciences, 39114 Magdeburg, Germany; (J.B.)
| | - Carlo von Diecken
- Department of Engineering and Industrial Design, Magdeburg-Stendal University of Applied Sciences, 39114 Magdeburg, Germany; (J.B.)
| | - Olaf Ueberschär
- Department of Engineering and Industrial Design, Magdeburg-Stendal University of Applied Sciences, 39114 Magdeburg, Germany; (J.B.)
- Department of Biomechanics and Sports Technology, Institute for Applied Training Science, 04109 Leipzig, Germany
| |
Collapse
|
6
|
Khoa BT, Huynh TT. Why do generation X customers use wearable fitness technology equipment after recovering from coronavirus? The role of perceived health risks. Heliyon 2024; 10:e32978. [PMID: 38984314 PMCID: PMC11231551 DOI: 10.1016/j.heliyon.2024.e32978] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2023] [Revised: 05/25/2024] [Accepted: 06/12/2024] [Indexed: 07/11/2024] Open
Abstract
The health sector has prioritized the physical health of vulnerable Generation X individuals at high Coronavirus risk. Despite vaccination efforts, both infected and healthy people continue facing health threats. Unlike other industries devastated by COVID-19, wearable fitness technology equipment (WFTE) is essential for health-focused individuals. This research examined customers' intention to use WFTE using an adapted Technology Acceptance Model (TAM) framework. A key contribution is the inclusion of perceived health risk and its impact on WFTE value perceptions and usage attitudes post-pandemic. The study gathered qualitative data from coronavirus patients and survey data from 513 participants. Structural equation modeling analysis supported the theoretical model. While the standard TAM evaluated intent to use WFTE, this study uniquely examined how WFTE's functional, hedonic, and symbolic value shapes its perceived value. Perceived health risk was found to significantly impact perceived WFTE value and usage attitudes after the pandemic recovery. Findings offer managerial implications to boost WFTE adoption among the vulnerable Generation X demographic.
Collapse
Affiliation(s)
- Bui Thanh Khoa
- Faculty of Commerce and Tourism, Industrial University of Ho Chi Minh City, Ho Chi Minh City, Viet Nam
| | | |
Collapse
|
7
|
Komarzynski S, Adams L, Davies EH. Case example of a female solo sailor competing in the Vendée Globe reveals extraordinary biological demands. J Sports Sci 2024; 42:793-802. [PMID: 38861588 DOI: 10.1080/02640414.2024.2365011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Accepted: 05/30/2024] [Indexed: 06/13/2024]
Abstract
The Vendée Globe is a non-stop, unassisted, single-handed round the world sailing race. It is regarded as the toughest sailing race, requiring high cognitive functioning and constant alertness. Little is known about the amount of sleep restriction and nutritional deficit experienced at sea and effects that fatigue have on sailors' performance. This report aimed to investigate these aspects by monitoring one of the female participants of the latest Vendée Globe. Sleep, food intake and stress were self-reported daily using specific app. Cognitive assessments were digitally completed. Heart rate and activity intensity were measured using a wrist-worn wearable device. Mean self-report sleep duration per 24 h was 3 hours 40 minutes. By the end of the 95 race days, the sailor reached a caloric deficit of 27,900 kcal. On average, the sailor spent 50 minutes per day in moderate-to-vigorous activity. Cognitive assessments did not show any effect of fatigue or stress on completion time or performance. Recent technological and communication advancement for offshore sailors, enabled continuous data to be monitored in near real time, even from the Southern Ocean. Moving forward this will enable greater understanding of when sailors will be at risk of poor decision making, illness or injury.
Collapse
Affiliation(s)
| | - L Adams
- Operations, Pip Hare Ocean Racing, Poole, UK
| | | |
Collapse
|
8
|
McGibbon CA, Sexton A, Gryfe P. Exercising with a robotic exoskeleton can improve memory and gait in people with Parkinson's disease by facilitating progressive exercise intensity. Sci Rep 2024; 14:4417. [PMID: 38388571 PMCID: PMC10883950 DOI: 10.1038/s41598-024-54200-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2023] [Accepted: 02/09/2024] [Indexed: 02/24/2024] Open
Abstract
People with Parkinson's disease (PwPD) can benefit from progressive high-intensity exercise facilitated with a lower-extremity exoskeleton, but the mechanisms explaining these benefits are unknown. We explored the relationship between exercise intensity progression and memory and gait outcomes in PwPD who performed 8 weeks (2 × per week) of progressive exercise with and without a lower-extremity powered exoskeleton, as the planned exploratory endpoint analysis of an open-label, parallel, pilot randomized controlled trial. Adults 50-85 years old with a confirmed diagnosis of PD participated. Twenty-seven participants randomized to exercise with (Exo = 13) or without (Nxo = 14) the exoskeleton were included in this exploratory endpoint analysis. Detailed exercise logs were kept and actigraphy was used to measure activity count*min-1 (ACPM) during all exercise sessions. Only the Exo group were able to progressively increase their ACPM over the entire 8-week intervention, whereas the Nxo group plateaued after 4 weeks. Exercise intensity progression correlated with change in the memory sub-scale of the SCOPA-COG and change in gait endurance from the 6MWT, consistent with the prevailing hypotheses linking high-intensity interval exercise to improved muscle and brain function via angiogenic and neurotrophic mechanisms. Facilitating high-intensity exercise with advanced rehabilitation technology is warranted for improving memory and gait endurance in PwPD.Registration: ClinicalTrials.gov, NCT03583879 (7/10/2018).
Collapse
Affiliation(s)
- Chris A McGibbon
- Institute of Biomedical Engineering, University of New Brunswick, 25 Dineen Dr, Fredericton, NB, E3B 5A3, Canada.
- Faculty of Kinesiology, University of New Brunswick, Fredericton, NB, Canada.
| | - Andrew Sexton
- Institute of Biomedical Engineering, University of New Brunswick, 25 Dineen Dr, Fredericton, NB, E3B 5A3, Canada
| | - Pearl Gryfe
- Assistive Technology Clinic, 107 Grenadier Cres, Thornhill, ON, L4J 7V7, Canada
| |
Collapse
|
9
|
Ibrahim NS, Rampal S, Lee WL, Pek EW, Suhaimi A. Evaluation of Wrist-Worn Photoplethysmography Trackers with an Electrocardiogram in Patients with Ischemic Heart Disease: A Validation Study. Cardiovasc Eng Technol 2024; 15:12-21. [PMID: 37973701 DOI: 10.1007/s13239-023-00693-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Accepted: 10/18/2023] [Indexed: 11/19/2023]
Abstract
PURPOSE Photoplethysmography measurement of heart rate with wrist-worn trackers has been introduced in healthy individuals. However, additional consideration is necessary for patients with ischemic heart disease, and the available evidence is limited. The study aims to evaluate the validity and reliability of heart rate measures by a wrist-worn photoplethysmography (PPG) tracker compared to an electrocardiogram (ECG) during incremental treadmill exercise among patients with ischemic heart disease. METHODS Fifty-one participants performed the standard incremental treadmill exercise in a controlled laboratory setting with 12-lead ECG attached to the patient's body and wearing wrist-worn PPG trackers. RESULTS At each stage, the absolute percentage error of the PPG was within 10% of the standard acceptable range. Further analysis using a linear mixed model, which accounts for individual variations, revealed that PPG yielded the best performance at the baseline low-intensity exercise. As the stages progressed, heart rate validity decreased but was regained during recovery. The reliability was moderate to excellent. CONCLUSIONS Low-cost trackers AMAZFIT Cor and Bip validity and reliability were within acceptable ranges, especially during low-intensity exercise among patients with ischemic heart disease recovering from cardiac procedures. Though using the tracker as part of the diagnosis tool still requires more supporting studies, it can potentially be used as a self-monitoring tool with precautions.
Collapse
Affiliation(s)
- Nur Syazwani Ibrahim
- Department of Rehabilitation Medicine, Faculty of Medicine, Universiti Malaya, 50603, Kuala Lumpur, Malaysia
| | - Sanjay Rampal
- Centre for Epidemiology and Evidence-based Practice, Department of Social and Preventive Medicine, Faculty of Medicine, Universiti Malaya, 50603, Kuala Lumpur, Malaysia.
| | - Wan Ling Lee
- Department of Nursing Science, Faculty of Medicine, Universiti Malaya, 50603, Kuala Lumpur, Malaysia
| | - Eu Way Pek
- Department of Rehabilitation Medicine, Faculty of Medicine, Universiti Malaya, 50603, Kuala Lumpur, Malaysia
| | - Anwar Suhaimi
- Department of Rehabilitation Medicine, Faculty of Medicine, Universiti Malaya, 50603, Kuala Lumpur, Malaysia.
| |
Collapse
|
10
|
Gajda R, Gajda J, Czuba M, Knechtle B, Drygas W. Sports Heart Monitors as Reliable Diagnostic Tools for Training Control and Detecting Arrhythmias in Professional and Leisure-Time Endurance Athletes: An Expert Consensus Statement. Sports Med 2024; 54:1-21. [PMID: 37906426 PMCID: PMC10799155 DOI: 10.1007/s40279-023-01948-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/02/2023] [Indexed: 11/02/2023]
Abstract
There are countless types of portable heart rate monitoring medical devices used variously by leisure-time exercisers, professional athletes, and chronically ill patients. Almost all the currently used heart rate monitors are capable of detecting arrhythmias, but this feature is not widely known or used among their millions of consumers. The aims of this paper were as follows: (1) to analyze the currently available sports heart rate monitors and assess their advantages and disadvantage in terms of heart rate and rhythm monitoring in endurance athletes; (2) to discuss what types of currently available commercial heart rate monitors are most convenient/adjustable to the needs of different consumers (including occasionally physically active adults and cardiac patients), bearing in mind the potential health risks, especially heart rhythm disturbances connected with endurance training; (3) to suggest a set of "optimal" design features for next-generation smart wearable devices based on the consensus opinion of an expert panel of athletes, coaches, and sports medicine doctors. Ninety-two experts aged 20 years and over, involved in endurance sports on a daily basis, were invited to participate in consensus-building discussions, including 56 long-distance runners, 18 cyclists, nine coaches, and nine physicians (sports medicine specialists, cardiologists, and family medicine doctors). The overall consensus endorsed by these experts indicates that the "optimal" sports heart rate monitor should be a one-piece device of the smartwatch type (with two or more electrodes), with integrated smartphone features, and able to collect and continually transmit data without exhibiting artifacts. It should continuously record at least a single-lead electrocardiography, send an alert after an unexpected fall, be of reasonable weight, come at an affordable price, and be user friendly.
Collapse
Affiliation(s)
- Robert Gajda
- Center for Sports Cardiology at the Gajda-Med Medical Center in Pułtusk, 06-100, Pułtusk, Poland.
- Department of Kinesiology and Health Prevention, Jan Dlugosz University, Czestochowa, Poland.
| | - Jacek Gajda
- Center for Sports Cardiology at the Gajda-Med Medical Center in Pułtusk, 06-100, Pułtusk, Poland
| | - Miłosz Czuba
- Faculty of Rehabilitation, Józef Piłsudski University of Physical Education in Warsaw, Warsaw, Poland
| | - Beat Knechtle
- Institute of Primary Care, University of Zurich, Zurich, Switzerland
- Medbase St. Gallen am Vadianplatz, St. Gallen, Switzerland
| | - Wojciech Drygas
- Department of Epidemiology, Cardiovascular Disease Prevention, and Health Promotion, The Cardinal Stefan Wyszynski National Institute of Cardiology, Warsaw, Poland
- Lazarski University, Warsaw, Poland
| |
Collapse
|
11
|
Novak R, Robinson JA, Kanduč T, Sarigiannis D, Džeroski S, Kocman D. Empowering Participatory Research in Urban Health: Wearable Biometric and Environmental Sensors for Activity Recognition. SENSORS (BASEL, SWITZERLAND) 2023; 23:9890. [PMID: 38139735 PMCID: PMC10747712 DOI: 10.3390/s23249890] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/19/2023] [Revised: 11/20/2023] [Accepted: 12/15/2023] [Indexed: 12/24/2023]
Abstract
Participatory exposure research, which tracks behaviour and assesses exposure to stressors like air pollution, traditionally relies on time-activity diaries. This study introduces a novel approach, employing machine learning (ML) to empower laypersons in human activity recognition (HAR), aiming to reduce dependence on manual recording by leveraging data from wearable sensors. Recognising complex activities such as smoking and cooking presents unique challenges due to specific environmental conditions. In this research, we combined wearable environment/ambient and wrist-worn activity/biometric sensors for complex activity recognition in an urban stressor exposure study, measuring parameters like particulate matter concentrations, temperature, and humidity. Two groups, Group H (88 individuals) and Group M (18 individuals), wore the devices and manually logged their activities hourly and minutely, respectively. Prioritising accessibility and inclusivity, we selected three classification algorithms: k-nearest neighbours (IBk), decision trees (J48), and random forests (RF), based on: (1) proven efficacy in existing literature, (2) understandability and transparency for laypersons, (3) availability on user-friendly platforms like WEKA, and (4) efficiency on basic devices such as office laptops or smartphones. Accuracy improved with finer temporal resolution and detailed activity categories. However, when compared to other published human activity recognition research, our accuracy rates, particularly for less complex activities, were not as competitive. Misclassifications were higher for vague activities (resting, playing), while well-defined activities (smoking, cooking, running) had few errors. Including environmental sensor data increased accuracy for all activities, especially playing, smoking, and running. Future work should consider exploring other explainable algorithms available on diverse tools and platforms. Our findings underscore ML's potential in exposure studies, emphasising its adaptability and significance for laypersons while also highlighting areas for improvement.
Collapse
Affiliation(s)
- Rok Novak
- Department of Environmental Sciences, Jožef Stefan Institute, 1000 Ljubljana, Slovenia; (J.A.R.); (T.K.); (D.K.)
- Ecotechnologies Programme, Jožef Stefan International Postgraduate School, 1000 Ljubljana, Slovenia;
| | - Johanna Amalia Robinson
- Department of Environmental Sciences, Jožef Stefan Institute, 1000 Ljubljana, Slovenia; (J.A.R.); (T.K.); (D.K.)
- Ecotechnologies Programme, Jožef Stefan International Postgraduate School, 1000 Ljubljana, Slovenia;
- Centre for Research and Development, Slovenian Institute for Adult Education, 1000 Ljubljana, Slovenia
| | - Tjaša Kanduč
- Department of Environmental Sciences, Jožef Stefan Institute, 1000 Ljubljana, Slovenia; (J.A.R.); (T.K.); (D.K.)
| | - Dimosthenis Sarigiannis
- Environmental Engineering Laboratory, Department of Chemical Engineering, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece;
- HERACLES Research Centre on the Exposome and Health, Centre for Interdisciplinary Research and Innovation, 57001 Thessaloniki, Greece
- Environmental Health Engineering, Department of Science, Technology and Society, University School of Advanced Study IUSS, 27100 Pavia, Italy
| | - Sašo Džeroski
- Ecotechnologies Programme, Jožef Stefan International Postgraduate School, 1000 Ljubljana, Slovenia;
- Department of Knowledge Technologies, Jožef Stefan Institute, 1000 Ljubljana, Slovenia
| | - David Kocman
- Department of Environmental Sciences, Jožef Stefan Institute, 1000 Ljubljana, Slovenia; (J.A.R.); (T.K.); (D.K.)
| |
Collapse
|
12
|
Wang TL, Wu HY, Wang WY, Chen CW, Chien WC, Chu CM, Wu YS. Assessment of Heart Rate Monitoring During Exercise With Smart Wristbands and a Heart Rhythm Patch: Validation and Comparison Study. JMIR Form Res 2023; 7:e52519. [PMID: 38096010 PMCID: PMC10755651 DOI: 10.2196/52519] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Revised: 11/10/2023] [Accepted: 11/24/2023] [Indexed: 12/31/2023] Open
Abstract
BACKGROUND The integration of wearable devices into fitness routines, particularly in military settings, necessitates a rigorous assessment of their accuracy. This study evaluates the precision of heart rate measurements by locally manufactured wristbands, increasingly used in military academies, to inform future device selection for military training activities. OBJECTIVE This research aims to assess the reliability of heart rate monitoring in chest straps versus wearable wristbands. METHODS Data on heart rate and acceleration were collected using the Q-Band Q-69 smart wristband (Mobile Action Technology Inc) and compared against the Zephyr Bioharness standard measuring device. The Lin concordance correlation coefficient, Pearson product moment correlation coefficient, and intraclass correlation coefficient were used for reliability analysis. RESULTS Participants from a Northern Taiwanese medical school were enrolled (January 1-June 31, 2021). The Q-Band Q-69 demonstrated that the mean absolute percentage error (MAPE) of women was observed to be 13.35 (SD 13.47). Comparatively, men exhibited a lower MAPE of 8.54 (SD 10.49). The walking state MAPE was 7.79 for women and 10.65 for men. The wristband's accuracy generally remained below 10% MAPE in other activities. Pearson product moment correlation coefficient analysis indicated gender-based performance differences, with overall coefficients of 0.625 for women and 0.808 for men, varying across walking, running, and cooldown phases. CONCLUSIONS This study highlights significant gender and activity-dependent variations in the accuracy of the MobileAction Q-Band Q-69 smart wristband. Reduced accuracy was notably observed during running. Occasional extreme errors point to the necessity of caution in relying on such devices for exercise monitoring. The findings emphasize the limitations and potential inaccuracies of wearable technology, especially in high-intensity physical activities.
Collapse
Affiliation(s)
- Tse-Lun Wang
- Division of Trauma and Surgical Critical Care, Department of Surgery, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung City, Taiwan
- Graduate Institute of Medicine, College of Medicine, Kaohsiung Medical University, Kaohsiung City, Taiwan
| | - Hao-Yi Wu
- Department of Nursing, Tri-Service General Hospital, Taipei City, Taiwan
| | - Wei-Yun Wang
- National Defense Medical Center and Department of Nursing, School of Nursing, Tri-Service General Hospital, Taipei City, Taiwan
| | - Chao-Wen Chen
- Division of Trauma and Surgical Critical Care, Department of Surgery, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung City, Taiwan
- Department of Emergency Medicine, Faculty of Medicine, College of Medicine, Kaohsiung Medical University, Kaohsiung City, Taiwan
| | - Wu-Chien Chien
- Department of Medical Research, Tri-Service General Hospital National Defense Medical Center, Taipei City, Taiwan
- School of Public Health, National Defense Medical Center, Taipei, Taiwan
- Graduate Institute of Life Sciences, National Defense Medical Center, Taipei, Taiwan
- Graduate Institute of Medical Sciences, National Defense Medical Center, Taipei, Taiwan
- Big Data Research Center, College of Medicine, Fu-Jen Catholic University, New Taipei City, Taiwan
| | - Chi-Ming Chu
- School of Public Health, National Defense Medical Center, Taipei, Taiwan
- Graduate Institute of Life Sciences, National Defense Medical Center, Taipei, Taiwan
- Graduate Institute of Medical Sciences, National Defense Medical Center, Taipei, Taiwan
- Big Data Research Center, College of Medicine, Fu-Jen Catholic University, New Taipei City, Taiwan
- Department of Public Health, Kaohsiung Medical University, Kaohsiung City, Taiwan
- Department of Public Health, China Medical University, Taichung City, Taiwan
| | - Yi-Syuan Wu
- Division of Trauma and Surgical Critical Care, Department of Surgery, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung City, Taiwan
| |
Collapse
|
13
|
Johnson NE, Venturo-Conerly KE, Rusch T. Using wearable activity trackers for research in the global south: Lessons learned from adolescent psychotherapy research in Kenya. Glob Ment Health (Camb) 2023; 10:e86. [PMID: 38161741 PMCID: PMC10755372 DOI: 10.1017/gmh.2023.85] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Revised: 10/13/2023] [Accepted: 11/23/2023] [Indexed: 01/03/2024] Open
Abstract
Wearable activity trackers have emerged as valuable tools for health research, providing high-resolution data on measures such as physical activity. While most research on these devices has been conducted in high-income countries, there is growing interest in their use in the global south. This perspective discusses the challenges faced and strategies employed when using wearable activity trackers to test the effects of a school-based intervention for depression and anxiety among Kenyan youth. Lessons learned include the importance of validating data output, establishing an internal procedure for international procurement, providing on-site support for participants, designating a full-time team member for wearable activity tracker operation, and issuing a paper-based information sheet to participants. The insights shared in this perspective serve as guidance for researchers undertaking studies with wearables in similar settings, contributing to the evidence base for mental health interventions targeting youth in the global south. Despite the challenges to set up, deploy and extract data from wearable activity trackers, we believe that wearables are a relatively economical approach to provide insight into the daily lives of research participants, and recommend their use to other researchers.
Collapse
Affiliation(s)
- Natalie E. Johnson
- Department of Research and Evidence, Shamiri Institute, Nairobi, Kenya
- Division of Clinical Epidemiology, Department of Clinical Research, University Hospital Basel, Basel, Switzerland
- Faculty of Medicine, University of Basel, Basel, Switzerland
| | - Katherine E. Venturo-Conerly
- Department of Research and Evidence, Shamiri Institute, Nairobi, Kenya
- Department of Psychology, Harvard University, Cambridge, MA, USA
| | - Thomas Rusch
- Competence Center for Empirical Research Methods, WU Vienna University of Economics and Business, Vienna, Austria
| |
Collapse
|
14
|
Carrier B, Salatto RW, Davis DW, Sertic JVL, Barrios B, McGinnis GR, Girouard TJ, Burroughs B, Navalta JW. Assessing the Validity of Several Heart Rate Monitors in Wearable Technology While Mountain Biking. INTERNATIONAL JOURNAL OF EXERCISE SCIENCE 2023; 16:1440-1450. [PMID: 38287935 PMCID: PMC10824301] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Subscribe] [Scholar Register] [Indexed: 01/31/2024]
Abstract
Purpose This study sought to assess the validity of several heart rate (HR) monitors in wearable technology during mountain biking (MTB), compared to the Polar H7® HR monitor, used as the criterion device. Methods A total of 20 participants completed two MTB trials while wearing six HR monitors (5 test devices, 1 criterion). HR was recorded on a second-by-second basis for all devices analyzed. After data processing, validity measures were calculated, including 1. error analysis: mean absolute percentage errors (MAPE), mean absolute error (MAE), and mean error (ME), and 2. Correlation analysis: Lin's concordance correlation coefficient (CCC) and Pearson's correlation coefficient (r). Thresholds for validity were set at MAPE < 10% and CCC > 0.7. Results The only device that was found to be valid during mountain biking was the Suunto Spartan Sport watch with accompanying HR monitor, with a MAPE of 0.66% and a CCC of 0.99 for the overall, combined data. Conclusion If a person would like to track their HR during mountain biking, for pacing, training, or other reasons, the devices best able to produce valid results are chest-based, wireless electrocardiogram (ECG) monitors, secured by elastic straps to minimize the movement of the device, such as the Suunto chest-based HR monitor.
Collapse
Affiliation(s)
- Bryson Carrier
- University of Nevada, Las Vegas; Department of Kinesiology and Nutrition Sciences
| | - R W Salatto
- Vanguard University; Department of Kinesiology
| | - Dustin W Davis
- University of Nevada, Las Vegas; Department of Kinesiology and Nutrition Sciences
| | | | - Brenna Barrios
- University of Nevada, Las Vegas; Department of Kinesiology and Nutrition Sciences
| | - Graham R McGinnis
- University of Nevada, Las Vegas; Department of Kinesiology and Nutrition Sciences
| | - Tedd J Girouard
- University of Nevada, Las Vegas; Department of Kinesiology and Nutrition Sciences
| | - Benjamin Burroughs
- University of Nevada, Las Vegas; Department of Journalism and Media Studies
| | - James W Navalta
- University of Nevada, Las Vegas; Department of Kinesiology and Nutrition Sciences
| |
Collapse
|
15
|
Loro FL, Martins R, de Araújo CLP, Prade LR, do Rosário DL, da Rocha Seruffo MC, de Freitas IAM, Nobre J, Both CB, Dal Lago P. Innovative and disruptive technologies to prescribe, encourage, and evaluate physical exercise in healthy adults: a protocol of exploratory study followed by a noninferiority, investigator-blinded randomized clinical trial. Trials 2023; 24:700. [PMID: 37904188 PMCID: PMC10614353 DOI: 10.1186/s13063-023-07747-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Accepted: 10/24/2023] [Indexed: 11/01/2023] Open
Abstract
BACKGROUND Cardiovascular diseases are a leading cause of mortality worldwide. A significant contributing factor to this mortality is the lack of engagement in preventive activities. Consequently, strategies for enhancing adherence to and duration of physical activity (PA) have become pivotal. This project aims to create and validate innovative, disruptive, and secure technologies that ensure appropriate exercise intensity, bolster adherence to PA, and monitor health biomarker responses pre-, during, and post-physical activity. METHODS This exploratory study, followed by a noninferiority, investigator-blinded randomized clinical trial, will be divided into three phases: (1) development and validation of a sensor for real-time biofeedback during a functional assessment test; (2) integration of biofeedback and gamification into an app for the structured prescription of physical training within a controlled setting; and (3) implementation of biofeedback and gamification into an app for the prescription and monitoring of physical training in an uncontrolled setting. Phase 1 entails a validation test of a biosensor-monitoring heart rate (HR) and steps-during a modified shuttle walk test. In phase 2, the biosensor interfaces with a gamified smartphone application. The training regimen spans 6 weeks, 5 days weekly, with each session lasting 60 min: a five-min warm-up involving stationary gait, followed by 50 min of training at the target HR on the step and concluding with a five-min cool-down at a stationary pace. After 6 weeks of training, a new functional capacity test is conducted. Phase 3 involves an investigator-blinded, randomized clinical trial to demonstrate noninferiority. Participants are randomly assigned to either the intervention group (IG) or the control group (CG). IG participants practice exercise using the gamified application in an uncontrolled environment according to the prescribed method outlined in phase 2. CG participants receive PA practice guidelines exclusively. DISCUSSION Anticipated outcomes include improved exercise adherence through the gamified application, better maintenance of prescribed exercise intensity, and enhanced health biomarkers. The results of this study will inform health-related decision-making. TRIAL REGISTRATION The study protocol received approval from the Ethics Committee of Universidade Federal de Ciências da Saúde de Porto Alegre (54,492,221.80000.5345) and has been registered with the Brazilian Registry of Clinical Trials (ReBEC, RBR-359p69v).
Collapse
Affiliation(s)
- Fernanda Laís Loro
- Universidade Federal de Ciências da Saúde de Porto Alegre, Sarmento Leite Street, 245, Porto Alegre, RS, CEP: 90050-170, Brazil
| | - Riane Martins
- Universidade Federal de Ciências da Saúde de Porto Alegre, Sarmento Leite Street, 245, Porto Alegre, RS, CEP: 90050-170, Brazil
| | - Cintia Laura Pereira de Araújo
- Universidade Federal de Ciências da Saúde de Porto Alegre, Sarmento Leite Street, 245, Porto Alegre, RS, CEP: 90050-170, Brazil
| | - Lucio Rene Prade
- Universidade do Vale do Rio dos Sinos, Unisinos Avenue, 950, São Leopoldo, RS, CEP: 93022-750, Brazil
| | - Denis Lima do Rosário
- Universidade Federal do Pará, Augusto Correa Street, 01, Belém, PA, CEP 66075110, Brazil
| | | | | | - Jéferson Nobre
- Universidade Federal do Rio Grande do Sul, Bento Gonçalves Avenue, 95000, Porto Alegre, RS, CEP 91501970, Brazil
| | - Cristiano Bonato Both
- Universidade do Vale do Rio dos Sinos, Unisinos Avenue, 950, São Leopoldo, RS, CEP: 93022-750, Brazil
| | - Pedro Dal Lago
- Universidade Federal de Ciências da Saúde de Porto Alegre, Sarmento Leite Street, 245, Porto Alegre, RS, CEP: 90050-170, Brazil.
| |
Collapse
|
16
|
Jørgensen A, Toftager M, Eghøj M, Ried-Larsen M, Bjørk Petersen C. Heart rate responses, agreement and accuracy among persons with severe disabilities participating in the indirect movement program: Team Twin-an observational study. Front Sports Act Living 2023; 5:1213655. [PMID: 37941848 PMCID: PMC10627970 DOI: 10.3389/fspor.2023.1213655] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Accepted: 09/22/2023] [Indexed: 11/10/2023] Open
Abstract
Introduction Heart rate (HR) monitors are rarely used by people living with disabilities (PLWD), and their accuracy is undocumented. Thus, this study aims to describe the HR response during the Team Twin co-running program and, secondly, to assess the agreement and accuracy of using HR monitors among PLWD. Methods This 16-week single-arm observational study included 18 people with various disabilities. During the study, the subjects wore a Garmin Vivosmart 4 watch (wrist). To evaluate the agreement and accuracy we applied Garmin's HRM-DUAL™ chest-worn HR monitors for comparison with the Vivosmart 4. The HR response analysis was performed descriptively and with a mixed regression model. The HR agreement and accuracy procedure was conducted on a subsample of five subjects and analyzed using Lin's concordance analysis, Bland and Altman's limits of agreement, and Cohen's kappa analysis of intensity zone agreement. This study was prospectively registered at Clinical Trials.gov (NCT04536779). Results The subjects had a mean age of 35 (±12.6), 61% were male, 72% had cerebral palsy were 85% had GMFCS V-IV. HR was monitored for 202:10:33 (HH:MM:SS), with a mean HR of 90 ± 17 bpm during training and race. A total of 19% of the time was spent in intensity zones between light and moderate (30%-59% HR reserve) and 1% in vigorous (60%-84% HR reserve). The remaining 80% were in the very light intensity zone (<29% HR reserve). HR was highest at the start of race and training and steadily decreased. Inter-rater agreement was high (k = 0.75), limits of agreement were between -16 and 13 bpm, and accuracy was acceptable (Rc = 0.86). Conclusion Disability type, individual, and contextual factors will likely affect HR responses and the agreement and accuracy for PLWD. The Vivosmart 4, while overall accurate, had low precision due to high variability in the estimation. These findings implicate the methodical and practical difficulties of utilizing HR monitors to measure HR and thus physical activity in adapted sports activities for severely disabled individuals.
Collapse
Affiliation(s)
- Andreas Jørgensen
- National Institute of Public Health, University of Southern Denmark, Copenhagen, Denmark
| | - Mette Toftager
- Department of Sports Science and Clinical Biomechanics, University of Southern Denmark, Odense, Denmark
| | - Martin Eghøj
- National Institute of Public Health, University of Southern Denmark, Copenhagen, Denmark
| | - Mathias Ried-Larsen
- Department of Sports Science and Clinical Biomechanics, University of Southern Denmark, Odense, Denmark
- Centre for Physical Activity Research, Copenhagen University Hospital—Rigshospitalet, Copenhagen, Denmark
| | | |
Collapse
|
17
|
Joshi J, Wang K, Cho Y. PhysioKit: An Open-Source, Low-Cost Physiological Computing Toolkit for Single- and Multi-User Studies. SENSORS (BASEL, SWITZERLAND) 2023; 23:8244. [PMID: 37837074 PMCID: PMC10575364 DOI: 10.3390/s23198244] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/03/2023] [Revised: 09/12/2023] [Accepted: 09/29/2023] [Indexed: 10/15/2023]
Abstract
The proliferation of physiological sensors opens new opportunities to explore interactions, conduct experiments and evaluate the user experience with continuous monitoring of bodily functions. Commercial devices, however, can be costly or limit access to raw waveform data, while low-cost sensors are efforts-intensive to setup. To address these challenges, we introduce PhysioKit, an open-source, low-cost physiological computing toolkit. PhysioKit provides a one-stop pipeline consisting of (i) a sensing and data acquisition layer that can be configured in a modular manner per research needs, and (ii) a software application layer that enables data acquisition, real-time visualization and machine learning (ML)-enabled signal quality assessment. This also supports basic visual biofeedback configurations and synchronized acquisition for co-located or remote multi-user settings. In a validation study with 16 participants, PhysioKit shows strong agreement with research-grade sensors on measuring heart rate and heart rate variability metrics data. Furthermore, we report usability survey results from 10 small-project teams (44 individual members in total) who used PhysioKit for 4-6 weeks, providing insights into its use cases and research benefits. Lastly, we discuss the extensibility and potential impact of the toolkit on the research community.
Collapse
|
18
|
Ruyak S, Roberts MH, Chambers S, Ma X, DiDomenico J, De La Garza R, Bakhireva LN. The effect of the COVID-19 pandemic on substance use patterns and physiological dysregulation in pregnant and postpartum women. ALCOHOL, CLINICAL & EXPERIMENTAL RESEARCH 2023; 47:1088-1099. [PMID: 37526587 PMCID: PMC10394275 DOI: 10.1111/acer.15077] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Revised: 02/19/2023] [Accepted: 03/25/2023] [Indexed: 08/02/2023]
Abstract
BACKGROUND The SARS-CoV-2/COVID-19 pandemic has been associated with increased stress levels and higher alcohol use, including in pregnant and postpartum women. In the general population, alcohol use is associated with dysregulation in the autonomic nervous system (ANS), which is indexed by heart rate variability (HRV). The objectives of this study were to: (1) characterize changes in substance use during the SARS-CoV-2/COVID-19 pandemic via a baseline self-report survey followed by mobile ecological momentary assessment (mEMA) of substance use; and (2) examine the associations between momentary substance use and ambulatory HRV measures in pregnant and postpartum women. METHODS Pregnant and postpartum women were identified from the ENRICH-2 prospective cohort study. Participants were administered a baseline structured phone interview that included the Coronavirus Perinatal Experiences (COPE) survey and ascertained the prevalence of substance use. Over a 14-day period, momentary substance use was assessed three times daily, and HRV measurements were captured via wearable electronics. Associations between momentary substance use and HRV measures (root mean square of successive differences [RMSSD] and low frequency/high frequency [LF/HF] ratio) were examined using a mixed effects model that included within-subject (WS) and between-subject (BS) effects and adjusted for pregnancy status and participant age. RESULTS The sample included 49 pregnant and 22 postpartum women. From a combination of a baseline and 14-day mEMA surveys, 21.2% reported alcohol use, 16.9% reported marijuana use, and 8.5% reported nicotine use. WS effects for momentary alcohol use were associated with the RMSSD (β = -0.14; p = 0.005) and LF/HF ratio (β = 0.14; p = 0.01) when controlling for pregnancy status and maternal age. No significant associations were observed between HRV measures and instances of marijuana or nicotine use. CONCLUSIONS These findings highlight the negative effect of the SARS-CoV-2/COVID-19 pandemic on the psychological health of pregnant and postpartum women associated with substance use, and in turn, ANS dysregulation, which potentially puts some women at risk of developing a substance use disorder.
Collapse
Affiliation(s)
- Sharon Ruyak
- College of Nursing, University of New Mexico, Albuquerque, New Mexico, USA
| | - Melissa H Roberts
- Substance Use Research and Education (SURE) Center, College of Pharmacy, University of New Mexico, Albuquerque, New Mexico, USA
| | - Stephanie Chambers
- Department of Family and Community Medicine, University of New Mexico, Albuquerque, New Mexico, USA
| | - Xingya Ma
- Substance Use Research and Education (SURE) Center, College of Pharmacy, University of New Mexico, Albuquerque, New Mexico, USA
| | - Jared DiDomenico
- Substance Use Research and Education (SURE) Center, College of Pharmacy, University of New Mexico, Albuquerque, New Mexico, USA
| | - Richard De La Garza
- Department of Psychiatry and Biobehavioral Sciences, David Geffen School of Medicine, University of California, Los Angeles, California, USA
| | - Ludmila N Bakhireva
- Substance Use Research and Education (SURE) Center, College of Pharmacy, University of New Mexico, Albuquerque, New Mexico, USA
| |
Collapse
|
19
|
Pardini S, Gabrielli S, Olivetto S, Fusina F, Dianti M, Forti S, Lancini C, Novara C. Personalized, Naturalistic Virtual Reality Scenarios Coupled With Web-Based Progressive Muscle Relaxation Training for the General Population: Protocol for a Proof-of-Principle Randomized Controlled Trial. JMIR Res Protoc 2023; 12:e44183. [PMID: 37067881 PMCID: PMC10152380 DOI: 10.2196/44183] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2022] [Revised: 02/15/2023] [Accepted: 02/28/2023] [Indexed: 04/18/2023] Open
Abstract
BACKGROUND Virtual reality (VR) is an innovative tool that can facilitate exposure to either stressful or relaxing stimuli and enables individuals who have difficulties visualizing scenes to be involved in a more realistic sensorimotor experience. It also facilitates multisensory stimulation, a sense of presence, and achievement of relaxation. VR scenarios representing visual and auditory elements of natural relaxing environments can facilitate the learning of relaxation techniques such as the progressive muscle relaxation technique (PMRT). A complementary standardized technique deployed to reduce anxiety symptoms is the integration of PMRT and guided imagery (GI). Exposure to a pleasant imaginary environment helps the establishment of an association between a relaxing scenario and the relaxation technique, consequently promoting relaxation. Empirical evidence has shown that VR scenarios can increase the effects of relaxation techniques by enabling people to experience emotional conditions in more vivid settings. OBJECTIVE The main aim of this pilot study protocol is to investigate the impact on state anxiety of PMRT, associated with a personalized relaxing scenario in VR, and the role of VR scenarios in facilitating the recall of relaxing images and a sense of presence. A secondary aim is to understand if relaxing sessions administered via Zoom are more effective for managing anxiety and stress than a procedural setting based on audio-track guidance. METHODS Based on a longitudinal, between-subject design, 108 university students will be randomly exposed to one of three experimental conditions: (1) PMRT via Zoom and GI exposure, (2) PMRT via Zoom and personalized VR exposure, and (3) PMRT based on audio-track guidance and personalized VR exposure. Individuals are assessed before and after 7 training sessions based on self-report questionnaires investigating anxiety, depression, quality of life, coping strategies, sense of presence, engagement, and side effects related to VR exposure. Heart rate data are also detected by an Mi Band 2 sensor. RESULTS The experimental procedure is ongoing. In this paper, preliminary data from a sample of 40 participants will be illustrated. The experimental phase is expected to conclude in May 2023, and the final results of the research will be presented in June 2023. CONCLUSIONS The results of this study will help shape the experimental design to apply it on a subsequent randomized controlled trial, also considering clinical samples. This work is expected to measure whether VR is a more engaging and helpful technique in promoting relaxation and decreasing anxiety levels than GI, by making the visualization process easier and by helping people to face more realistic sensory experiences. Assessing the efficacy of the PMRT in alternative delivery modes may extend its applications, especially in situations where the standard procedure is more challenging to be administered. To our knowledge, no equivalent study has been published so far on this matter. TRIAL REGISTRATION ClinicalTrials.gov NCT05478941; https://clinicaltrials.gov/ct2/show/NCT05478941. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID) DERR1-10.2196/44183.
Collapse
Affiliation(s)
- Susanna Pardini
- Department of General Psychology, University of Padova, Padova, Italy
- Digital Health Lab, Centre for Health and Wellbeing, Fondazione Bruno Kessler, Trento, Italy
- Human Inspired Technology Research Centre, University of Padova, Padova, Italy
| | - Silvia Gabrielli
- Digital Health Lab, Centre for Health and Wellbeing, Fondazione Bruno Kessler, Trento, Italy
| | - Silvia Olivetto
- Department of General Psychology, University of Padova, Padova, Italy
| | - Francesca Fusina
- Department of General Psychology, University of Padova, Padova, Italy
- Padova Neuroscience Center, University of Padova, Padova, Italy
| | - Marco Dianti
- Digital Health Lab, Centre for Health and Wellbeing, Fondazione Bruno Kessler, Trento, Italy
| | - Stefano Forti
- Digital Health Lab, Centre for Health and Wellbeing, Fondazione Bruno Kessler, Trento, Italy
| | - Cristina Lancini
- Department of General Psychology, University of Padova, Padova, Italy
| | - Caterina Novara
- Department of General Psychology, University of Padova, Padova, Italy
| |
Collapse
|
20
|
Speed C, Arneil T, Harle R, Wilson A, Karthikesalingam A, McConnell M, Phillips J. Measure by measure: Resting heart rate across the 24-hour cycle. PLOS DIGITAL HEALTH 2023; 2:e0000236. [PMID: 37115739 PMCID: PMC10146540 DOI: 10.1371/journal.pdig.0000236] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2022] [Accepted: 03/20/2023] [Indexed: 04/29/2023]
Abstract
BACKGROUND Photoplethysmography (PPG) sensors, typically found in wrist-worn devices, can continuously monitor heart rate (HR) in large populations in real-world settings. Resting heart rate (RHR) is an important biomarker of morbidities and mortality, but no universally accepted definition nor measurement criteria exist. In this study, we provide a working definition of RHR and describe a method for accurate measurement of this biomarker, recorded using PPG derived from wristband measurement across the 24-hour cycle. METHODS 433 healthy subjects wore a wrist device that measured activity and HR for up to 3 months. HR during inactivity was recorded and the duration of inactivity needed for HR to stabilise was ascertained. We identified the lowest HR during each 24-hour cycle (true RHR) and examined the time of day or night this occurred. The variation of HR during inactivity through the 24-hour cycle was also assessed. The sample was also subdivided according to daily activity levels for subset analysis. FINDINGS Adequate data was obtained for 19,242 days and 18,520 nights. HR stabilised in most subjects after 4 minutes of inactivity. Mean (SD) RHR for the sample was 54.5 (8.0) bpm (day) and 50.5 (7.6) bpm (night). RHR values were highest in the least active group (lowest MET quartile). A circadian variation of HR during inactivity was confirmed, with the lowest values being between 0300 and 0700 hours for most subjects. INTERPRETATION RHR measured using a PPG-based wrist-worn device is significantly lower at night than in the day, and a circadian rhythm of HR during inactivity was confirmed. Since RHR is such an important health metric, clarity on the definition and measurement methodology used is important. For most subjects, a minimum rest time of 4 minutes provides a reliable measurement of HR during inactivity and true RHR in a 24-hour cycle is best measured between 0300 and 0700 hours. Funding: This study was funded by Google.
Collapse
Affiliation(s)
- Cathy Speed
- Google, Mountain View, California, United States of America
- Cambridge Health & Performance, Cambridge, United Kingdom
- Cardiff Metropolitan University, Cardiff, United Kingdom
| | - Thomas Arneil
- Google, Mountain View, California, United States of America
| | - Robert Harle
- Google, Mountain View, California, United States of America
- Computer Laboratory, University of Cambridge, Cambridge, United Kingdom
| | - Alex Wilson
- Google, Mountain View, California, United States of America
| | | | - Michael McConnell
- Google, Mountain View, California, United States of America
- Division of Cardiovascular Medicine, Stanford University School of Medicine, Stanford, California, United States of America
| | | |
Collapse
|
21
|
Caldirola D, Daccò S, Grassi M, Alciati A, Sbabo WM, De Donatis D, Martinotti G, De Berardis D, Perna G. Cardiorespiratory Assessments in Panic Disorder Facilitated by Wearable Devices: A Systematic Review and Brief Comparison of the Wearable Zephyr BioPatch with the Quark-b2 Stationary Testing System. Brain Sci 2023; 13:brainsci13030502. [PMID: 36979312 PMCID: PMC10046237 DOI: 10.3390/brainsci13030502] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2023] [Revised: 03/06/2023] [Accepted: 03/10/2023] [Indexed: 03/19/2023] Open
Abstract
Abnormalities in cardiorespiratory measurements have repeatedly been found in patients with panic disorder (PD) during laboratory-based assessments. However, recordings performed outside laboratory settings are required to test the ecological validity of these findings. Wearable devices, such as sensor-imbedded garments, biopatches, and smartwatches, are promising tools for this purpose. We systematically reviewed the evidence for wearables-based cardiorespiratory assessments in PD by searching for publications on the PubMed, PsycINFO, and Embase databases, from inception to 30 July 2022. After the screening of two-hundred and twenty records, eight studies were included. The limited number of available studies and critical aspects related to the uncertain reliability of wearables-based assessments, especially concerning respiration, prevented us from drawing conclusions about the cardiorespiratory function of patients with PD in daily life. We also present preliminary data on a pilot study conducted on volunteers at the Villa San Benedetto Menni Hospital for evaluating the accuracy of heart rate (HR) and breathing rate (BR) measurements by the wearable Zephyr BioPatch compared with the Quark-b2 stationary testing system. Our exploratory results suggested possible BR and HR misestimation by the wearable Zephyr BioPatch compared with the Quark-b2 system. Challenges of wearables-based cardiorespiratory assessment and possible solutions to improve their reliability and optimize their significant potential for the study of PD pathophysiology are presented.
Collapse
Affiliation(s)
- Daniela Caldirola
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, 20090 Pieve Emanuele, Italy
- Department of Clinical Neurosciences, Villa San Benedetto Menni Hospital, Hermanas Hospitalarias, Via Roma 16, 22032 Albese con Cassano, Italy
- Humanitas San Pio X, Personalized Medicine Center for Anxiety and Panic Disorders, Via Francesco Nava 31, 20159 Milan, Italy
| | - Silvia Daccò
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, 20090 Pieve Emanuele, Italy
- Department of Clinical Neurosciences, Villa San Benedetto Menni Hospital, Hermanas Hospitalarias, Via Roma 16, 22032 Albese con Cassano, Italy
| | - Massimiliano Grassi
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, 20090 Pieve Emanuele, Italy
| | - Alessandra Alciati
- Department of Clinical Neurosciences, Villa San Benedetto Menni Hospital, Hermanas Hospitalarias, Via Roma 16, 22032 Albese con Cassano, Italy
- Humanitas Clinical and Research Center, IRCCS, Via Manzoni 56, 20089 Rozzano, Italy
| | - William M. Sbabo
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, 20090 Pieve Emanuele, Italy
| | - Domenico De Donatis
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, 20090 Pieve Emanuele, Italy
- Humanitas San Pio X, Personalized Medicine Center for Anxiety and Panic Disorders, Via Francesco Nava 31, 20159 Milan, Italy
| | - Giovanni Martinotti
- Department of Neuroscience, Imaging and Clinical Sciences, University “G. d’Annunzio”, 66100 Chieti, Italy
| | - Domenico De Berardis
- Department of Mental Health, NHS, ASL 4 Teramo, Contrada Casalena, 64100 Teramo, Italy
- Correspondence:
| | - Giampaolo Perna
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, 20090 Pieve Emanuele, Italy
- Department of Clinical Neurosciences, Villa San Benedetto Menni Hospital, Hermanas Hospitalarias, Via Roma 16, 22032 Albese con Cassano, Italy
- Humanitas San Pio X, Personalized Medicine Center for Anxiety and Panic Disorders, Via Francesco Nava 31, 20159 Milan, Italy
| |
Collapse
|
22
|
ter Harmsel JF, Noordzij ML, van der Pol TM, Swinkels LTA, Goudriaan AE, Popma A. Exploring the effects of a wearable biocueing app (Sense-IT) as an addition to aggression regulation therapy in forensic psychiatric outpatients. Front Psychol 2023; 14:983286. [PMID: 36968738 PMCID: PMC10036768 DOI: 10.3389/fpsyg.2023.983286] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Accepted: 01/18/2023] [Indexed: 03/12/2023] Open
Abstract
ObjectivePreventing and reducing violence is of high importance for both individuals and society. However, the overall efficacy of current treatment interventions aimed at reducing aggressive behavior is limited. New technological-based interventions may enhance treatment outcomes, for instance by facilitating out-of-session practice and providing just-in-time support. Therefore, the aim of this study was to assess the effects of the Sense-IT biocueing app as an addition to aggression regulation therapy (ART) on interoceptive awareness, emotion regulation, and aggressive behavior among forensic outpatients.MethodsA combination of methods was used. Quantitatively, a pretest-posttest design was applied to explore group changes in aggression, emotion regulation, and anger bodily sensations associated with the combination of biocueing intervention and ART. Measures were assessed at pretest, after 4 weeks posttest, and after one-month follow-up. During the 4 weeks, a single-case experimental ABA design was applied for each participant. Biocueing was added in the intervention phase. During all phases anger, aggressive thoughts, aggressive behavior, behavioral control, and physical tension were assessed twice a day, and heart rate was measured continuously. Qualitative information regarding interoceptive awareness, coping, and aggression was collected at posttest. 25 forensic outpatients participated.ResultsA significant decrease in self-reported aggression was found between pre- and posttest. Furthermore, three-quarters of participants reported increased interoceptive awareness associated with the biocueing intervention. However, the repeated ambulatory measurements of the single-case experimental designs (SCEDs) did not indicate a clear effect favoring the addition of biocueing. On group level, no significant effects were found. On the individual level, effects favoring the intervention were only found for two participants. Overall, effect sizes were small.ConclusionBiocueing seems a helpful addition to increase interoceptive awareness among forensic outpatients. However, not all patients benefit from the current intervention and, more specifically, from its behavioral support component aimed at enhancing emotion regulation. Future studies should therefore focus on increasing usability, tailoring the intervention to individual needs, and on integration into therapy. Individual characteristics associated with effective support by a biocueing intervention should be further investigated, as the use of personalized and technological-based treatment interventions is expected to increase in the coming years.
Collapse
Affiliation(s)
- Janna F. ter Harmsel
- Forensic Mental Healthcare, Inforsa, Amsterdam, Netherlands
- Department of Child and Adolescent Psychiatry and Psychology, Amsterdam Public Health Research Institute, Amsterdam UMC, Vrije Universiteit Amsterdam, Amsterdam, Netherlands
- *Correspondence: Janna F. ter Harmsel,
| | - Matthijs L. Noordzij
- Department of Psychology, Health and Technology, University of Twente, Enschede, Netherlands
| | - Thimo M. van der Pol
- Forensic Mental Healthcare, Inforsa, Amsterdam, Netherlands
- Department of Child and Adolescent Psychiatry and Psychology, Amsterdam Public Health Research Institute, Amsterdam UMC, Vrije Universiteit Amsterdam, Amsterdam, Netherlands
- Department of Research and Quality of Care, Arkin Mental Health Institute, Amsterdam, Netherlands
| | - Lise T. A. Swinkels
- Forensic Mental Healthcare, Inforsa, Amsterdam, Netherlands
- Department of Child and Adolescent Psychiatry and Psychology, Amsterdam Public Health Research Institute, Amsterdam UMC, Vrije Universiteit Amsterdam, Amsterdam, Netherlands
| | - Anna E. Goudriaan
- Department of Research and Quality of Care, Arkin Mental Health Institute, Amsterdam, Netherlands
- Department of Psychiatry, Amsterdam Public Health Research Institute, Amsterdam UMC, University of Amsterdam, Amsterdam, Netherlands
- Amsterdam Institute for Addiction Research, Amsterdam, Netherlands
| | - Arne Popma
- Department of Child and Adolescent Psychiatry and Psychology, Amsterdam Public Health Research Institute, Amsterdam UMC, Vrije Universiteit Amsterdam, Amsterdam, Netherlands
| |
Collapse
|
23
|
Kim C, Kim SH, Suh MR. Accuracy and Validity of Commercial Smart Bands for Heart Rate Measurements During Cardiopulmonary Exercise Test. Ann Rehabil Med 2022; 46:209-218. [PMID: 36071003 PMCID: PMC9452288 DOI: 10.5535/arm.22050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2022] [Accepted: 07/01/2022] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE To assess the accuracies and validities of popular smart bands for heart rate (HR) measurement in cardiovascular disease (CVD) patients during a graded exercise test (GXT). METHODS Seventy-eight patients were randomly assigned to wear two different smart bands out of three possible choices: Samsung Galaxy Fit 2, Xiaomi Mi Band 5, or Partron PWB-250 on each wrist. A 12-lead exercise electrocardiogram (ECG) and patch-type single-lead ECG were used to assess the comparative HR accuracy of the smart bands. The HR was recorded during the GXT using the modified Bruce protocol. RESULTS The concordance correlation coefficients (rc) were calculated to provide a measure of agreement between each device and the ECG. In all conditions, the Mi Band 5 and Galaxy Fit 2' correlations were rc>0.90, while the PWB-250 correlation was rc=0.58 at rest. When evaluating the accuracy according to the magnitude of HR, all smart bands performed well (rc>0.90) when the HR was below 100 but accuracy tended to decrease with higher HR values. CONCLUSION This study showed that the three smart bands had a high level of accuracy for HR measurements during low-intensity exercise. However, during moderate-intensity and high-intensity exercise, all the three smart bands performed less accurately. Further studies are needed to find a more optimal smart band for HR measurement that can be used for precise HR monitoring during formal cardiac rehabilitation exercise training, including at high and maximal intensity (Clinical Trial Registration No. cris.nih.go.kr/KCT0007036).
Collapse
Affiliation(s)
- Chul Kim
- Department of Rehabilitation Medicine, Sanggye Paik Hospital, Inje University College of Medicine, Seoul, Korea
| | - Seung Hyoun Kim
- Department of Rehabilitation Medicine, Sanggye Paik Hospital, Seoul, Korea
| | - Mi Rim Suh
- Department of Rehabilitation Medicine, Sanggye Paik Hospital, Inje University College of Medicine, Seoul, Korea
| |
Collapse
|
24
|
Presseller EK, Patarinski AGG, Fan SC, Lampe EW, Juarascio AS. Sensor technology in eating disorders research: A systematic review. Int J Eat Disord 2022; 55:573-624. [PMID: 35489036 DOI: 10.1002/eat.23715] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/20/2021] [Revised: 04/02/2022] [Accepted: 04/03/2022] [Indexed: 12/14/2022]
Abstract
OBJECTIVE Sensor technologies offer exciting potential to objectively measure psychopathological correlates of eating pathology and eating disorder (ED) research utilizing sensors has rapidly proliferated in the past several years. The aims of the present review are: (1) characterize the types of sensors that have been utilized in ED research, (2) identify the psychopathological factors relevant to EDs that have been assessed using sensors, (3) describe the data supporting the validity and reliability of these sensors, (4) discuss limitations associated with these sensors, and (5) identify gaps that persist within the ED literature with regard to use of sensor technologies. METHOD A systematic search was conducted of PubMed, PsycINFO, Web of Science, ProQuest, and "gray" literature sources. Eligible publications were empirical studies that utilized sensors to measure at least one psychological variable among clinical ED populations. RESULTS Sensors have been utilized with ED samples to measure eating behaviors, physical activity, sleep, autonomic nervous system activity, eyeblink startle response, visual attention, and visual-haptic object integration. The reliability and validity of these sensors varies widely and there are a number of significant gaps that remain in the literature with regard to the types of sensors utilized, context in which sensors have been used, and populations studied. DISCUSSION The existing literature utilizing sensors within ED research largely support the feasibility and acceptability of these tools. Sensors should continue to be utilized within the field, with a specific focus on examining the reliability and validity of these tools within ED samples and increasing the diversity of samples studied. PUBLIC SIGNIFICANCE STATEMENT Sensor technologies, such as those included in modern smartwatches, offer new opportunities to measure factors that may maintain or contribute to symptoms of eating disorders. This article describes the types of sensors that have been used in eating disorders research, challenges that may arise in using these sensors, and discusses new applications of these sensors that may be pursued in future research.
Collapse
Affiliation(s)
- Emily K Presseller
- Department of Psychological and Brain Sciences, Drexel University, Philadelphia, Pennsylvania, USA.,Center for Weight, Eating, and Lifestyle Science, Drexel University, Philadelphia, Pennsylvania, USA
| | | | - Stephanie C Fan
- Department of Psychological and Brain Sciences, Drexel University, Philadelphia, Pennsylvania, USA
| | - Elizabeth W Lampe
- Department of Psychological and Brain Sciences, Drexel University, Philadelphia, Pennsylvania, USA.,Center for Weight, Eating, and Lifestyle Science, Drexel University, Philadelphia, Pennsylvania, USA
| | - Adrienne S Juarascio
- Department of Psychological and Brain Sciences, Drexel University, Philadelphia, Pennsylvania, USA.,Center for Weight, Eating, and Lifestyle Science, Drexel University, Philadelphia, Pennsylvania, USA
| |
Collapse
|
25
|
Shei RJ, Holder IG, Oumsang AS, Paris BA, Paris HL. Wearable activity trackers-advanced technology or advanced marketing? Eur J Appl Physiol 2022; 122:1975-1990. [PMID: 35445837 PMCID: PMC9022022 DOI: 10.1007/s00421-022-04951-1] [Citation(s) in RCA: 34] [Impact Index Per Article: 17.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2021] [Accepted: 04/04/2022] [Indexed: 11/26/2022]
Abstract
Wearable devices represent one of the most popular trends in health and fitness. Rapid advances in wearable technology present a dizzying display of possible functions: from thermometers and barometers, magnetometers and accelerometers, to oximeters and calorimeters. Consumers and practitioners utilize wearable devices to track outcomes, such as energy expenditure, training load, step count, and heart rate. While some rely on these devices in tandem with more established tools, others lean on wearable technology for health-related outcomes, such as heart rhythm analysis, peripheral oxygen saturation, sleep quality, and caloric expenditure. Given the increasing popularity of wearable devices for both recreation and health initiatives, understanding the strengths and limitations of these technologies is increasingly relevant. Need exists for continued evaluation of the efficacy of wearable devices to accurately and reliably measure purported outcomes. The purposes of this review are (1) to assess the current state of wearable devices using recent research on validity and reliability, (2) to describe existing gaps between physiology and technology, and (3) to offer expert interpretation for the lay and professional audience on how best to approach wearable technology and employ it in the pursuit of health and fitness. Current literature demonstrates inconsistent validity and reliability for various metrics, with algorithms not publicly available or lacking high-quality validation studies. Advancements in wearable technology should consider standardizing validation metrics, providing transparency in used algorithms, and improving how technology can be tailored to individuals. Until then, it is prudent to exercise caution when interpreting metrics reported from consumer-wearable devices.
Collapse
Affiliation(s)
- Ren-Jay Shei
- Indiana University Alumni Association, Indiana University, 1000 E 17th Street, Bloomington, IN, 47408, USA.
| | - Ian G Holder
- Department of Sports Medicine, Pepperdine University, Malibu, CA, USA
| | - Alicia S Oumsang
- Department of Sports Medicine, Pepperdine University, Malibu, CA, USA
| | - Brittni A Paris
- Department of Sports Medicine, Pepperdine University, Malibu, CA, USA
| | - Hunter L Paris
- Department of Sports Medicine, Pepperdine University, Malibu, CA, USA
| |
Collapse
|
26
|
Marutani Y, Konda S, Ogasawara I, Yamasaki K, Yokoyama T, Maeshima E, Nakata K. An Experimental Feasibility Study Evaluating the Adequacy of a Sportswear-Type Wearable for Recording Exercise Intensity. SENSORS (BASEL, SWITZERLAND) 2022; 22:2577. [PMID: 35408192 PMCID: PMC9003462 DOI: 10.3390/s22072577] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/28/2021] [Revised: 02/07/2022] [Accepted: 03/25/2022] [Indexed: 11/16/2022]
Abstract
Sportswear-type wearables with integrated inertial sensors and electrocardiogram (ECG) electrodes have been commercially developed. We evaluated the feasibility of using a sportswear-type wearable with integrated inertial sensors and electrocardiogram (ECG) electrodes for evaluating exercise intensity within a controlled laboratory setting. Six male college athletes were asked to wear a sportswear-type wearable while performing a treadmill test that reached up to 20 km/h. The magnitude of the filtered tri-axial acceleration signal, recorded by the inertial sensor, was used to calculate the acceleration index. The R-R intervals of the ECG were used to determine heart rate; the external validity of the heart rate was then evaluated according to oxygen uptake, which is the gold standard for physiological exercise intensity. Single regression analysis between treadmill speed and the acceleration index in each participant showed that the slope of the regression line was significantly greater than zero with a high coefficient of determination (walking, 0.95; jogging, 0.96; running, 0.90). Another single regression analysis between heart rate and oxygen uptake showed that the slope of the regression line was significantly greater than zero, with a high coefficient of determination (0.96). Together, these results indicate that the sportswear-type wearable evaluated in this study is a feasible technology for evaluating physical and physiological exercise intensity across a wide range of physical activities and sport performances.
Collapse
Affiliation(s)
- Yoshihiro Marutani
- Graduate School of Sport and Exercise Sciences, Osaka University of Health and Sport Sciences, Kumatori 590-0496, Osaka, Japan; (Y.M.); (E.M.)
- Department of Health and Sport Sciences, Osaka University Graduate School of Medicine, Toyonaka 560-0043, Osaka, Japan; (S.K.); (I.O.); (K.Y.); (T.Y.)
| | - Shoji Konda
- Department of Health and Sport Sciences, Osaka University Graduate School of Medicine, Toyonaka 560-0043, Osaka, Japan; (S.K.); (I.O.); (K.Y.); (T.Y.)
- Department of Sports Medical Biomechanics, Osaka University Graduate School of Medicine, Suita 565-0871, Osaka, Japan
| | - Issei Ogasawara
- Department of Health and Sport Sciences, Osaka University Graduate School of Medicine, Toyonaka 560-0043, Osaka, Japan; (S.K.); (I.O.); (K.Y.); (T.Y.)
- Department of Sports Medical Biomechanics, Osaka University Graduate School of Medicine, Suita 565-0871, Osaka, Japan
| | - Keita Yamasaki
- Department of Health and Sport Sciences, Osaka University Graduate School of Medicine, Toyonaka 560-0043, Osaka, Japan; (S.K.); (I.O.); (K.Y.); (T.Y.)
| | - Teruki Yokoyama
- Department of Health and Sport Sciences, Osaka University Graduate School of Medicine, Toyonaka 560-0043, Osaka, Japan; (S.K.); (I.O.); (K.Y.); (T.Y.)
| | - Etsuko Maeshima
- Graduate School of Sport and Exercise Sciences, Osaka University of Health and Sport Sciences, Kumatori 590-0496, Osaka, Japan; (Y.M.); (E.M.)
| | - Ken Nakata
- Department of Health and Sport Sciences, Osaka University Graduate School of Medicine, Toyonaka 560-0043, Osaka, Japan; (S.K.); (I.O.); (K.Y.); (T.Y.)
| |
Collapse
|
27
|
Is the Xiaomi Mi Band 4 an Accuracy Tool for Measuring Health-Related Parameters in Adults and Older People? An Original Validation Study. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph19031593. [PMID: 35162615 PMCID: PMC8834826 DOI: 10.3390/ijerph19031593] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/22/2021] [Revised: 01/26/2022] [Accepted: 01/27/2022] [Indexed: 12/04/2022]
Abstract
Background: The aim of this study was to analyse the validity and accuracy of the low-cost Xiaomi Mi Band 4 (MB4) fitness tracker in relation to step count and heart rate in free-living conditions. Methods: 46 participants join in this study (38.65 ± 14.36 years old). The MB4 was compared with a video recording in laboratory conditions, also with the Sense Wear and Firstbeat monitors in free-living conditions. Results: No significant differences were found in the number of steps in the laboratory protocol between devices, in both, at low and high walking speed. For the free-living conditions, the MB4 showed high values of convergent validity in relation to the Firstbeat monitor during recording in both rest and walking situations. Moreover, the MB4 showed adequate values of convergent validity with the Sense Wear monitor during the 24 h recording, at medium speeds, and climbing stairs. Conclusion: The accuracy and precision of the MB4 is reasonable and can be used to monitor the average of step count and heart rate in free-living conditions.
Collapse
|
28
|
Recent Advances in Wearable Optical Sensor Automation Powered by Battery versus Skin-like Battery-Free Devices for Personal Healthcare-A Review. NANOMATERIALS 2022; 12:nano12030334. [PMID: 35159679 PMCID: PMC8838083 DOI: 10.3390/nano12030334] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/09/2021] [Revised: 01/15/2022] [Accepted: 01/19/2022] [Indexed: 12/11/2022]
Abstract
Currently, old-style personal Medicare techniques rely mostly on traditional methods, such as cumbersome tools and complicated processes, which can be time consuming and inconvenient in some circumstances. Furthermore, such old methods need the use of heavy equipment, blood draws, and traditional bench-top testing procedures. Invasive ways of acquiring test samples can potentially cause patient discomfort and anguish. Wearable sensors, on the other hand, may be attached to numerous body areas to capture diverse biochemical and physiological characteristics as a developing analytical tool. Physical, chemical, and biological data transferred via the skin are used to monitor health in various circumstances. Wearable sensors can assess the aberrant conditions of the physical or chemical components of the human body in real time, exposing the body state in time, thanks to unintrusive sampling and high accuracy. Most commercially available wearable gadgets are mechanically hard components attached to bands and worn on the wrist, with form factors ultimately constrained by the size and weight of the batteries required for the power supply. Basic physiological signals comprise a lot of health-related data. The estimation of critical physiological characteristics, such as pulse inconstancy or variability using photoplethysmography (PPG) and oxygen saturation in arterial blood using pulse oximetry, is possible by utilizing an analysis of the pulsatile component of the bloodstream. Wearable gadgets with “skin-like” qualities are a new type of automation that is only starting to make its way out of research labs and into pre-commercial prototypes. Flexible skin-like sensing devices have accomplished several functionalities previously inaccessible for typical sensing devices due to their deformability, lightness, portability, and flexibility. In this paper, we studied the recent advancement in battery-powered wearable sensors established on optical phenomena and skin-like battery-free sensors, which brings a breakthrough in wearable sensing automation.
Collapse
|
29
|
Anomaly Detection Framework for Wearables Data: A Perspective Review on Data Concepts, Data Analysis Algorithms and Prospects. SENSORS 2022; 22:s22030756. [PMID: 35161502 PMCID: PMC8840097 DOI: 10.3390/s22030756] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/16/2021] [Revised: 01/11/2022] [Accepted: 01/15/2022] [Indexed: 12/23/2022]
Abstract
Wearable devices use sensors to evaluate physiological parameters, such as the heart rate, pulse rate, number of steps taken, body fat and diet. The continuous monitoring of physiological parameters offers a potential solution to assess personal healthcare. Identifying outliers or anomalies in heart rates and other features can help identify patterns that can play a significant role in understanding the underlying cause of disease states. Since anomalies are present within the vast amount of data generated by wearable device sensors, identifying anomalies requires accurate automated techniques. Given the clinical significance of anomalies and their impact on diagnosis and treatment, a wide range of detection methods have been proposed to detect anomalies. Much of what is reported herein is based on previously published literature. Clinical studies employing wearable devices are also increasing. In this article, we review the nature of the wearables-associated data and the downstream processing methods for detecting anomalies. In addition, we also review supervised and un-supervised techniques as well as semi-supervised methods that overcome the challenges of missing and un-annotated healthcare data.
Collapse
|
30
|
Budig M, Keiner M, Stoohs R, Hoffmeister M, Höltke V. Heart Rate and Distance Measurement of Two Multisport Activity Trackers and a Cellphone App in Different Sports: A Cross-Sectional Validation and Comparison Field Study. SENSORS (BASEL, SWITZERLAND) 2021; 22:180. [PMID: 35009723 PMCID: PMC8749603 DOI: 10.3390/s22010180] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/19/2021] [Revised: 12/24/2021] [Accepted: 12/26/2021] [Indexed: 11/16/2022]
Abstract
Options for monitoring sports have been continuously developed by using activity trackers to determine almost all vital and movement parameters. The aim of this study was to validate heart rate and distance measurements of two activity trackers (Polar Ignite; Garmin Forerunner 945) and a cellphone app (Polar Beat app using iPhone 7 as a hardware platform) in a cross-sectional field study. Thirty-six moderate endurance-trained adults (20 males/16 females) completed a test battery consisting of walking and running 3 km, a 1.6 km interval run (standard 400 m outdoor stadium), 3 km forest run (outdoor), 500/1000 m swim and 4.3/31.5 km cycling tests. Heart rate was recorded via a Polar H10 chest strap and distance was controlled via a map, 400 m stadium or 50 m pool. For all tests except swimming, strong correlation values of r > 0.90 were calculated with moderate exercise intensity and a mean absolute percentage error of 2.85%. During the interval run, several significant deviations (p < 0.049) were observed. The swim disciplines showed significant differences (p < 0.001), with the 500 m test having a mean absolute percentage error of 8.61%, and the 1000 m test of 55.32%. In most tests, significant deviations (p < 0.001) were calculated for distance measurement. However, a maximum mean absolute percentage error of 4.74% and small mean absolute error based on the total route lengths were calculated. This study showed that the accuracy of heart rate measurements could be rated as good, except for rapid changing heart rate during interval training and swimming. Distance measurement differences were rated as non-relevant in practice for use in sports.
Collapse
Affiliation(s)
- Mario Budig
- Department of Sports Science, German University of Health & Sport, 85737 Ismaning, Germany; (M.B.); (M.H.); (V.H.)
| | - Michael Keiner
- Department of Sports Science, German University of Health & Sport, 85737 Ismaning, Germany; (M.B.); (M.H.); (V.H.)
| | | | - Meike Hoffmeister
- Department of Sports Science, German University of Health & Sport, 85737 Ismaning, Germany; (M.B.); (M.H.); (V.H.)
| | - Volker Höltke
- Department of Sports Science, German University of Health & Sport, 85737 Ismaning, Germany; (M.B.); (M.H.); (V.H.)
| |
Collapse
|
31
|
Jachymek M, Jachymek MT, Kiedrowicz RM, Kaźmierczak J, Płońska-Gościniak E, Peregud-Pogorzelska M. Wristbands in Home-Based Rehabilitation-Validation of Heart Rate Measurement. SENSORS 2021; 22:s22010060. [PMID: 35009603 PMCID: PMC8747642 DOI: 10.3390/s22010060] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/27/2021] [Revised: 12/17/2021] [Accepted: 12/20/2021] [Indexed: 11/29/2022]
Abstract
The possibility of using a smartwatch as a rehabilitation tool to monitor patients’ heart rates during exercise has gained the attention of many researchers. This study aimed to evaluate the accuracy and precision of the HR measurement performed by two wrist monitors: the Fitbit Charge 4 and the Xiaomi Mi Band 5. Thirty-one healthy volunteers were asked to perform a stress test on a treadmill. Their heart rates were recorded simultaneously by the wristbands and an electrocardiogram (ECG) at 1 min intervals. The mean absolute error percentage (MAPE), Lin’s concordance correlation coefficient (LCCC), and Bland–Altman analysis were calculated to compare the precision and accuracy of heart rate measurements. The estimated validation criteria were MAPE < 10% and LCCC < 0.8. The overall MAPE and LCCC of the Fitbit were 10.19% (±11.79%) and 0.753 (95% CI: 0.717–0.785), respectively. The MAPE and LCCC of the Xiaomi were 6.89% (±9.75) and 0.903 (0.886–0.917), respectively. The precision and accuracy of both devices decreased with the increased exercise intensity. The accuracy of wearable wrist-worn heart rate monitors varies and depends on the intensity of training. Therefore, the decision to use such a device as a heart rate monitor during in-home rehabilitation should be made with caution.
Collapse
Affiliation(s)
- Magdalena Jachymek
- Cardiology Clinic, Pomeranian Medical University, ul Powstańców Wielkopolskich 72, 70-111 Szczecin, Poland; (R.M.K.); (J.K.); (E.P.-G.); (M.P.-P.)
- Correspondence: ; Tel.: +48-914661378
| | - Michał T. Jachymek
- Physiotherapy Department, University of Social Sciences, ul. Sienkiewicza 9, 90-113 Lodz, Poland;
| | - Radosław M. Kiedrowicz
- Cardiology Clinic, Pomeranian Medical University, ul Powstańców Wielkopolskich 72, 70-111 Szczecin, Poland; (R.M.K.); (J.K.); (E.P.-G.); (M.P.-P.)
| | - Jarosław Kaźmierczak
- Cardiology Clinic, Pomeranian Medical University, ul Powstańców Wielkopolskich 72, 70-111 Szczecin, Poland; (R.M.K.); (J.K.); (E.P.-G.); (M.P.-P.)
| | - Edyta Płońska-Gościniak
- Cardiology Clinic, Pomeranian Medical University, ul Powstańców Wielkopolskich 72, 70-111 Szczecin, Poland; (R.M.K.); (J.K.); (E.P.-G.); (M.P.-P.)
| | - Małgorzata Peregud-Pogorzelska
- Cardiology Clinic, Pomeranian Medical University, ul Powstańców Wielkopolskich 72, 70-111 Szczecin, Poland; (R.M.K.); (J.K.); (E.P.-G.); (M.P.-P.)
| |
Collapse
|
32
|
Santamaria-Granados L, Mendoza-Moreno JF, Chantre-Astaiza A, Munoz-Organero M, Ramirez-Gonzalez G. Tourist Experiences Recommender System Based on Emotion Recognition with Wearable Data. SENSORS (BASEL, SWITZERLAND) 2021; 21:7854. [PMID: 34883853 PMCID: PMC8659453 DOI: 10.3390/s21237854] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/01/2021] [Revised: 11/18/2021] [Accepted: 11/22/2021] [Indexed: 01/01/2023]
Abstract
The collection of physiological data from people has been facilitated due to the mass use of cheap wearable devices. Although the accuracy is low compared to specialized healthcare devices, these can be widely applied in other contexts. This study proposes the architecture for a tourist experiences recommender system (TERS) based on the user's emotional states who wear these devices. The issue lies in detecting emotion from Heart Rate (HR) measurements obtained from these wearables. Unlike most state-of-the-art studies, which have elicited emotions in controlled experiments and with high-accuracy sensors, this research's challenge consisted of emotion recognition (ER) in the daily life context of users based on the gathering of HR data. Furthermore, an objective was to generate the tourist recommendation considering the emotional state of the device wearer. The method used comprises three main phases: The first was the collection of HR measurements and labeling emotions through mobile applications. The second was emotional detection using deep learning algorithms. The final phase was the design and validation of the TERS-ER. In this way, a dataset of HR measurements labeled with emotions was obtained as results. Among the different algorithms tested for ER, the hybrid model of Convolutional Neural Networks (CNN) and Long Short-Term Memory (LSTM) networks had promising results. Moreover, concerning TERS, Collaborative Filtering (CF) using CNN showed better performance.
Collapse
Affiliation(s)
- Luz Santamaria-Granados
- GIDINT, Faculty of Systems Engineering, Universidad Santo Tomás Seccional Tunja, Calle 19, No. 11-64, Tunja 150001, Colombia;
| | - Juan Francisco Mendoza-Moreno
- GIDINT, Faculty of Systems Engineering, Universidad Santo Tomás Seccional Tunja, Calle 19, No. 11-64, Tunja 150001, Colombia;
| | - Angela Chantre-Astaiza
- SysTémico Research Group, Department of Tourism Sciences, Universidad del Cauca, Calle 5, No. 4-70, Popayán 190002, Colombia;
| | - Mario Munoz-Organero
- GAST, Telematics Engineering Department, Universidad Carlos III de Madrid, Av. de la Universidad, 30, 28911 Madrid, Spain;
| | | |
Collapse
|
33
|
Zhang Y, Trace CB. The quality of health and wellness self‐tracking data: A consumer perspective. J Assoc Inf Sci Technol 2021. [DOI: 10.1002/asi.24591] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- Yan Zhang
- School of Information The University of Texas at Austin Austin Texas USA
| | - Ciaran B. Trace
- School of Information The University of Texas at Austin Austin Texas USA
| |
Collapse
|
34
|
Teixeira E, Fonseca H, Diniz-Sousa F, Veras L, Boppre G, Oliveira J, Pinto D, Alves AJ, Barbosa A, Mendes R, Marques-Aleixo I. Wearable Devices for Physical Activity and Healthcare Monitoring in Elderly People: A Critical Review. Geriatrics (Basel) 2021; 6:38. [PMID: 33917104 PMCID: PMC8167657 DOI: 10.3390/geriatrics6020038] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2021] [Revised: 03/25/2021] [Accepted: 04/02/2021] [Indexed: 01/22/2023] Open
Abstract
The availability of wearable devices (WDs) to collect biometric information and their use during activities of daily living is significantly increasing in the general population. These small electronic devices, which record fitness and health-related outcomes, have been broadly utilized in industries such as medicine, healthcare, and fitness. Since they are simple to use and progressively cheaper, they have also been used for numerous research purposes. However, despite their increasing popularity, most of these WDs do not accurately measure the proclaimed outcomes. In fact, research is equivocal about whether they are valid and reliable methods to specifically evaluate physical activity and health-related outcomes in older adults, since they are mostly designed and produced considering younger subjects' physical and mental characteristics. Additionally, their constant evolution through continuous upgrades and redesigned versions, suggests the need for constant up-to-date reviews and research. Accordingly, this article aims to scrutinize the state-of-the-art scientific evidence about the usefulness of WDs, specifically on older adults, to monitor physical activity and health-related outcomes. This critical review not only aims to inform older consumers but also aid researchers in study design when selecting physical activity and healthcare monitoring devices for elderly people.
Collapse
Affiliation(s)
- Eduardo Teixeira
- Research Centre in Physical Activity, Health, and Leisure (CIAFEL), Faculty of Sport, University of Porto, 4200-450 Porto, Portugal
- Faculty of Psychology, Education and Sports, Lusófona University of Porto, 4000-098 Porto, Portugal
- Escola Superior Desporto e Lazer, Instituto Politécnico de Viana do Castelo, 4900-347 Viana do Castelo, Portugal
- Laboratory for Integrative and Translational Research in Population Health (ITR), 4050-600 Porto, Portugal
| | - Hélder Fonseca
- Research Centre in Physical Activity, Health, and Leisure (CIAFEL), Faculty of Sport, University of Porto, 4200-450 Porto, Portugal
- Laboratory for Integrative and Translational Research in Population Health (ITR), 4050-600 Porto, Portugal
| | - Florêncio Diniz-Sousa
- Research Centre in Physical Activity, Health, and Leisure (CIAFEL), Faculty of Sport, University of Porto, 4200-450 Porto, Portugal
- Laboratory for Integrative and Translational Research in Population Health (ITR), 4050-600 Porto, Portugal
| | - Lucas Veras
- Research Centre in Physical Activity, Health, and Leisure (CIAFEL), Faculty of Sport, University of Porto, 4200-450 Porto, Portugal
- Laboratory for Integrative and Translational Research in Population Health (ITR), 4050-600 Porto, Portugal
| | - Giorjines Boppre
- Research Centre in Physical Activity, Health, and Leisure (CIAFEL), Faculty of Sport, University of Porto, 4200-450 Porto, Portugal
- Laboratory for Integrative and Translational Research in Population Health (ITR), 4050-600 Porto, Portugal
| | - José Oliveira
- Research Centre in Physical Activity, Health, and Leisure (CIAFEL), Faculty of Sport, University of Porto, 4200-450 Porto, Portugal
- Laboratory for Integrative and Translational Research in Population Health (ITR), 4050-600 Porto, Portugal
| | - Diogo Pinto
- Research Center in Sports Sciences, Health Sciences and Human Development (CIDESD), University Institute of Maia, 4475-690 Maia, Portugal
| | - Alberto Jorge Alves
- Research Center in Sports Sciences, Health Sciences and Human Development (CIDESD), University Institute of Maia, 4475-690 Maia, Portugal
| | - Ana Barbosa
- Laboratory for Integrative and Translational Research in Population Health (ITR), 4050-600 Porto, Portugal
- EPIUnit-Instituto de Saúde Pública, Universidade do Porto, 4050-091 Porto, Portugal
| | - Romeu Mendes
- Laboratory for Integrative and Translational Research in Population Health (ITR), 4050-600 Porto, Portugal
- EPIUnit-Instituto de Saúde Pública, Universidade do Porto, 4050-091 Porto, Portugal
- Northern Region Health Administration, 4000-477 Porto, Portugal
| | - Inês Marques-Aleixo
- Research Centre in Physical Activity, Health, and Leisure (CIAFEL), Faculty of Sport, University of Porto, 4200-450 Porto, Portugal
- Faculty of Psychology, Education and Sports, Lusófona University of Porto, 4000-098 Porto, Portugal
- Laboratory for Integrative and Translational Research in Population Health (ITR), 4050-600 Porto, Portugal
| |
Collapse
|
35
|
Remote Monitoring of Critically-Ill Post-Surgical Patients: Lessons from a Biosensor Implementation Trial. Healthcare (Basel) 2021; 9:healthcare9030343. [PMID: 33803575 PMCID: PMC8002865 DOI: 10.3390/healthcare9030343] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2021] [Revised: 03/01/2021] [Accepted: 03/06/2021] [Indexed: 12/14/2022] Open
Abstract
Biosensors represent one of the numerous promising technologies envisioned to extend healthcare delivery. In perioperative care, the healthcare delivery system can use biosensors to remotely supervise patients who would otherwise be admitted to a hospital. This novel technology has gained a foothold in healthcare with significant acceleration due to the COVID-19 pandemic. However, few studies have attempted to narrate, or systematically analyze, the process of their implementation. We performed an observational study of biosensor implementation. The data accuracy provided by the commercially available biosensors was compared to those offered by standard clinical monitoring on patients admitted to the intensive care unit/perioperative unit. Surveys were also conducted to examine the acceptance of technology by patients and medical staff. We demonstrated a significant difference in vital signs between sensors and standard monitoring which was very dependent on the measured variables. Sensors seemed to integrate into the workflow relatively quickly, with almost no reported problems. The acceptance of the biosensors was high by patients and slightly less by nurses directly involved in the patients’ care. The staff forecast a broad implementation of biosensors in approximately three to five years, yet are eager to learn more about them. Reliability considerations proved particularly troublesome in our implementation trial. Careful evaluation of sensor readiness is most likely necessary prior to system-wide implementation by each hospital to assess for data accuracy and acceptance by the staff.
Collapse
|
36
|
Komarzynski S, Wreglesworth NI, Griffiths D, Pecchia L, Subbe CP, Hughes SF, Davies EH, Innominato PF. Embracing Change: Learnings From Implementing Multidimensional Digital Remote Monitoring in Oncology Patients at a District General Hospital During the COVID-19 Pandemic. JCO Clin Cancer Inform 2021; 5:216-220. [PMID: 33606562 DOI: 10.1200/cci.20.00136] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Affiliation(s)
| | - Nicholas I Wreglesworth
- Oncology Department, Ysbyty Gwynedd, Betsi Cadwaladr University Health Board, Bangor, UK.,School of Medical Sciences, Bangor University, Bangor, UK
| | - Dawn Griffiths
- Oncology Department, Ysbyty Gwynedd, Betsi Cadwaladr University Health Board, Bangor, UK
| | | | - Christian P Subbe
- School of Medical Sciences, Bangor University, Bangor, UK.,Acute and Critical Care Medicine, Ysbyty Gwynedd, Betsi Cadwaladr University Health Board, Bangor, UK
| | - Stephen F Hughes
- North Wales Clinical Research Centre, Betsi Cadwaladr University Health Board, Wrexham, UK
| | | | - Pasquale F Innominato
- Oncology Department, Ysbyty Gwynedd, Betsi Cadwaladr University Health Board, Bangor, UK.,Cancer Chronotherapy Team, Warwick Medical School, University of Warwick, Coventry, UK.,European Laboratory U935, Institut National de la Santé et de la Recherche Médicale (INSERM), Paris-Saclay University, Villejuif, France
| |
Collapse
|
37
|
Mühlen JM, Stang J, Lykke Skovgaard E, Judice PB, Molina-Garcia P, Johnston W, Sardinha LB, Ortega FB, Caulfield B, Bloch W, Cheng S, Ekelund U, Brønd JC, Grøntved A, Schumann M. Recommendations for determining the validity of consumer wearable heart rate devices: expert statement and checklist of the INTERLIVE Network. Br J Sports Med 2021; 55:767-779. [PMID: 33397674 PMCID: PMC8273688 DOI: 10.1136/bjsports-2020-103148] [Citation(s) in RCA: 36] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/24/2020] [Indexed: 01/06/2023]
Abstract
Assessing vital signs such as heart rate (HR) by wearable devices in a lifestyle-related environment provides widespread opportunities for public health related research and applications. Commonly, consumer wearable devices assessing HR are based on photoplethysmography (PPG), where HR is determined by absorption and reflection of emitted light by the blood. However, methodological differences and shortcomings in the validation process hamper the comparability of the validity of various wearable devices assessing HR. Towards Intelligent Health and Well-Being: Network of Physical Activity Assessment (INTERLIVE) is a joint European initiative of six universities and one industrial partner. The consortium was founded in 2019 and strives towards developing best-practice recommendations for evaluating the validity of consumer wearables and smartphones. This expert statement presents a best-practice validation protocol for consumer wearables assessing HR by PPG. The recommendations were developed through the following multi-stage process: (1) a systematic literature review based on the Preferred Reporting Items for Systematic Reviews and Meta-Analyses, (2) an unstructured review of the wider literature pertaining to factors that may introduce bias during the validation of these devices and (3) evidence-informed expert opinions of the INTERLIVE Network. A total of 44 articles were deemed eligible and retrieved through our systematic literature review. Based on these studies, a wider literature review and our evidence-informed expert opinions, we propose a validation framework with standardised recommendations using six domains: considerations for the target population, criterion measure, index measure, testing conditions, data processing and the statistical analysis. As such, this paper presents recommendations to standardise the validity testing and reporting of PPG-based HR wearables used by consumers. Moreover, checklists are provided to guide the validation protocol development and reporting. This will ensure that manufacturers, consumers, healthcare providers and researchers use wearables safely and to its full potential.
Collapse
Affiliation(s)
- Jan M Mühlen
- Institute of Cardiovascular Research and Sports Medicine, Department of Molecular and Cellular Sports Medicine, German Sport University Cologne, Cologne, Germany
| | - Julie Stang
- Department of Sports Medicine, Norwegian School of Sport Sciences, Oslo, Norway
| | - Esben Lykke Skovgaard
- Department of Sports Science and Clinical Biomechanics, Research Unit for Exercise Epidemiology, Centre of Research in Childhood Health, University of Southern Denmark, Odense, Denmark
| | - Pedro B Judice
- Exercise and Health Laboratory, CIPER, Faculdade de Motricidade Humana, Universidade de Lisboa, Lisboa, Portugal.,CIDEFES - Centro de Investigação em Desporto, Educação Física e Exercício e Saúde, Universidade Lusófona, Lisboa, Portugal
| | - Pablo Molina-Garcia
- PROFITH "PROmoting FITness and Health through physical activity" Research Group, Sport and Health University Research Institute (iMUDS), Department of Physical and Sports Education, Faculty of Sport Sciences, University of Granada, Granada, Spain
| | - William Johnston
- SFI Insight Centre for Data Analytics, University College Dublin, Dublin, Ireland.,School of Public Health, Physiotherapy and Sports Science, University College Dublin, Dublin, Ireland
| | - Luís B Sardinha
- Exercise and Health Laboratory, CIPER, Faculdade de Motricidade Humana, Universidade de Lisboa, Lisboa, Cruz-Quebrada Dafundo, Portugal
| | - Francisco B Ortega
- PROFITH "PROmoting FITness and Health through physical activity" Research Group, Sport and Health University Research Institute (iMUDS), Department of Physical and Sports Education, Faculty of Sport Sciences, University of Granada, Granada, Spain.,Department of Biosciences and Nutrition, Karolinska Institute, Stockholm, Sweden
| | - Brian Caulfield
- SFI Insight Centre for Data Analytics, University College Dublin, Dublin, Ireland.,School of Public Health, Physiotherapy and Sports Science, University College Dublin, Dublin, Ireland
| | - Wilhelm Bloch
- Institute of Cardiovascular Research and Sports Medicine, Department of Molecular and Cellular Sports Medicine, German Sport University Cologne, Cologne, Germany
| | - Sulin Cheng
- Institute of Cardiovascular Research and Sports Medicine, Department of Molecular and Cellular Sports Medicine, German Sport University Cologne, Cologne, Germany.,Exercise Translational Medicine Centre, the Key Laboratory of Systems Biomedicine, Ministry of Education, and Exercise, Health and Technology Centre, Department of Physical Education, Shanghai Jiao Tong University, Shanghai, China
| | - Ulf Ekelund
- Department of Sports Medicine, Norwegian School of Sport Sciences, Oslo, Norway
| | - Jan Christian Brønd
- Department of Sports Science and Clinical Biomechanics, Research Unit for Exercise Epidemiology, Centre of Research in Childhood Health, University of Southern Denmark, Odense, Denmark
| | - Anders Grøntved
- Department of Sports Science and Clinical Biomechanics, Research Unit for Exercise Epidemiology, Centre of Research in Childhood Health, University of Southern Denmark, Odense, Denmark
| | - Moritz Schumann
- Institute of Cardiovascular Research and Sports Medicine, Department of Molecular and Cellular Sports Medicine, German Sport University Cologne, Cologne, Germany .,Exercise Translational Medicine Centre, the Key Laboratory of Systems Biomedicine, Ministry of Education, and Exercise, Health and Technology Centre, Department of Physical Education, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
38
|
Shedding Light on Nocturnal Movements in Parkinson's Disease: Evidence from Wearable Technologies. SENSORS 2020; 20:s20185171. [PMID: 32927816 PMCID: PMC7571235 DOI: 10.3390/s20185171] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/06/2020] [Revised: 09/04/2020] [Accepted: 09/09/2020] [Indexed: 12/13/2022]
Abstract
In Parkinson’s disease (PD), abnormal movements consisting of hypokinetic and hyperkinetic manifestations commonly lead to nocturnal distress and sleep impairment, which significantly impact quality of life. In PD patients, these nocturnal disturbances can reflect disease-related complications (e.g., nocturnal akinesia), primary sleep disorders (e.g., rapid eye movement behaviour disorder), or both, thus requiring different therapeutic approaches. Wearable technologies based on actigraphy and innovative sensors have been proposed as feasible solutions to identify and monitor the various types of abnormal nocturnal movements in PD. This narrative review addresses the topic of abnormal nocturnal movements in PD and discusses how wearable technologies could help identify and assess these disturbances. We first examine the pathophysiology of abnormal nocturnal movements and the main clinical and instrumental tools for the evaluation of these disturbances in PD. We then report and discuss findings from previous studies assessing nocturnal movements in PD using actigraphy and innovative wearable sensors. Finally, we discuss clinical and technical prospects supporting the use of wearable technologies for the evaluation of nocturnal movements.
Collapse
|
39
|
Ahmad Tarar A, Mohammad U, K. Srivastava S. Wearable Skin Sensors and Their Challenges: A Review of Transdermal, Optical, and Mechanical Sensors. BIOSENSORS 2020; 10:E56. [PMID: 32481598 PMCID: PMC7345448 DOI: 10.3390/bios10060056] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/22/2020] [Revised: 05/15/2020] [Accepted: 05/25/2020] [Indexed: 12/21/2022]
Abstract
Wearable technology and mobile healthcare systems are both increasingly popular solutions to traditional healthcare due to their ease of implementation and cost-effectiveness for remote health monitoring. Recent advances in research, especially the miniaturization of sensors, have significantly contributed to commercializing the wearable technology. Most of the traditional commercially available sensors are either mechanical or optical, but nowadays transdermal microneedles are also being used for micro-sensing such as continuous glucose monitoring. However, there remain certain challenges that need to be addressed before the possibility of large-scale deployment. The biggest challenge faced by all these wearable sensors is our skin, which has an inherent property to resist and protect the body from the outside world. On the other hand, biosensing is not possible without overcoming this resistance. Consequently, understanding the skin structure and its response to different types of sensing is necessary to remove the scientific barriers that are hindering our ability to design more efficient and robust skin sensors. In this article, we review research reports related to three different biosensing modalities that are commonly used along with the challenges faced in their implementation for detection. We believe this review will be of significant use to researchers looking to solve existing problems within the ongoing research in wearable sensors.
Collapse
Affiliation(s)
- Ammar Ahmad Tarar
- Department of Biological Engineering, University of Idaho, Moscow, ID 83844, USA;
| | - Umair Mohammad
- Department of Electrical & Computer Engineering, University of Idaho, Moscow, ID 83844, USA;
| | - Soumya K. Srivastava
- Department of Chemical & Materials Engineering, University of Idaho, Moscow, ID 83844, USA
| |
Collapse
|