1
|
Mapping estimates of vascular permeability with a clinical indocyanine green fluorescence imaging system in experimental pancreatic adenocarcinoma tumors. JOURNAL OF BIOMEDICAL OPTICS 2023; 28:076001. [PMID: 37457627 PMCID: PMC10344470 DOI: 10.1117/1.jbo.28.7.076001] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Revised: 06/18/2023] [Accepted: 06/22/2023] [Indexed: 07/18/2023]
Abstract
Significance Pancreatic cancer tumors are known to be avascular, but their neovascular capillaries are still chaotic leaky vessels. Capillary permeability could have significant value for therapy assessment, and its quantification might be possible with macroscopic imaging of indocyanine green (ICG) kinetics in tissue. Aim The capacity of using standard fluorescence surgical systems for ICG kinetic imaging as a probe for capillary leakage was evaluated using a clinical surgical fluorescence imaging system, as interpreted through vascular permeability modeling. Approach Xenograft pancreatic adenocarcinoma models were imaged in mice during bolus injection of ICG to capture the kinetics of uptake. Image analysis included ratiometric data, normalization, and match to theoretical modeling. Kinetic data were converted into the extraction fraction of the capillary leakage. Results Pancreatic tumors were usually less fluorescent than the surrounding healthy tissues, but still the rate of tumor perfusion could be assessed to quantify capillary extraction. Model simulations showed that flow kinetics stabilized after about 1 min beyond the initial bolus injection and that the relative extraction fraction model estimates matched the experimental data of normalized uptake within the tissue. The kinetics in the time period of 1 to 2 min post-injection provided optimal differential data between AsPC1 and BxPC3 tumors, although high individual variation exists between tumors. Conclusions ICG kinetic imaging during the initial leakage phase was diagnostic for quantitative vascular permeability within pancreatic tumors. Methods for autogain correction and normalized model-based interpretation allowed for quantification of extraction fraction and difference identification between tumor types in early timepoints.
Collapse
|
2
|
Simulation Analysis of a Wavefront Reconstruction of a Large Aperture Laser Beam. SENSORS (BASEL, SWITZERLAND) 2023; 23:623. [PMID: 36679420 PMCID: PMC9866099 DOI: 10.3390/s23020623] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/09/2022] [Revised: 01/02/2023] [Accepted: 01/04/2023] [Indexed: 06/17/2023]
Abstract
In order to solve the problem of atmospheric influence on the far-field measurement of the quality of a laser beam, we proposed a direct wavefront measurement system based on the Hartmann detection principle, which can measure large apertures and high-power laser beams. The measuring system was composed of a lens array and a detector. The wavefront detection of a large aperture laser beam could be realized by controlling the distance between the lenses and the size of the lens. The influence of different duty cycle factors on the accuracy of the wavefront reconstruction under the same arrangement and different arrangement conditions was simulated and analyzed. The simulation results showed that when the sub-lenses of the system were not in close contact, the reconstruction accuracy of the duty factor of 0.8 was close to that of the case of the duty factor of 1. Within a certain detection range, the hexagonal arrangement of 19 lenses and the arrangement of 8 × 8 lens arrays had a high wavefront restoration accuracy; both were lower than 0.10 λ. The system proposed in this paper was suitable for measuring a large aperture laser beam, providing a new idea for measuring and analyzing the quality of large aperture laser beams. It also has an important significance for improving the measurement accuracy of the beam quality.
Collapse
|
3
|
Editorial: Optical Molecular Imaging in Cancer Research. Front Oncol 2022; 12:870583. [PMID: 35419283 PMCID: PMC8995548 DOI: 10.3389/fonc.2022.870583] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2022] [Accepted: 02/24/2022] [Indexed: 11/13/2022] Open
|
4
|
Comparison of RetCam and Smartphone-Based Photography for Retinopathy of Prematurity Screening. Diagnostics (Basel) 2022; 12:diagnostics12040945. [PMID: 35453993 PMCID: PMC9029155 DOI: 10.3390/diagnostics12040945] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Revised: 04/01/2022] [Accepted: 04/09/2022] [Indexed: 11/16/2022] Open
Abstract
This study aimed to compare the clinical performance between a smartphone-based fundus photography device and a contact imaging device for retinopathy of prematurity (ROP) screening. All patients were first examined with binocular indirect ophthalmoscopy (BIO), which served as the reference standard. The patients were then assessed by two devices. Imaging quality, ability to judge the zone and stage of ROP, agreement with the BIO results, vital signs, and pain scores were compared between these two devices. In total, 142 eyes of 71 infants were included. For the smartphone-based fundus photography, image quality was graded excellent or acceptable in 91.4% of examinations, although it was still significantly inferior to that of the contact imaging device (p < 0.001). The smartphone-based fundus photography images had moderate agreement with the BIO results regarding the presence or absence of plus disease (Cohen’s κ = 0.619), but evaluating the zone (p < 0.001) and stage (p < 0.001) of ROP was difficult. Systemic parameters, except for heart rate, were similar between the two imaging devices (all p > 0.05). In conclusion, although the smartphone-based fundus photography showed moderate agreement for determining the presence or absence of plus disease, it failed to identify the zone and stage of ROP.
Collapse
|
5
|
The false positive rates for detecting keratoconus and potential ectatic corneal conditions when evaluating astigmatic eyes with Scheimpflug Technology. Eur J Ophthalmol 2022; 32:2532-2546. [PMID: 35313744 DOI: 10.1177/11206721221081467] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
PURPOSE To quantify the false positive rates for keratoconus (KC) and potential ectatic corneal conditions in highly astigmatism eyes when using published parameters/indices obtained from the Pentacam and Galilei units. SETTING Oftalmosalud Instituto de Ojos, Lima, Peru. DESIGN Prospective cohort study. METHODS 67 consecutive eyes with corneal astigmatism > 1.5 D, with a minimum follow ups of 36 months after an uneventful LASIK procedure were included. Indices for KC and other potential ectatic corneal conditions (subclinical KC, forme fruste KC, suspect KC) were obtained using the Pentacam and Galilei Scheimpflug cameras. MAIN OUTCOME MEASURES The false positive rates for KC and potential ectatic corneal conditions were measured. Cut off values provided by previous studies and company-based parameters were used to assess the rate of false positivity. RESULTS The range of false positive rates for a KC diagnosis depending on the lowest and highest cutoff values were: index of height decentration (61% - 1%), index of surface variance (76% - 0%), Posterior elevation (55% - 0%), maximum Ambrosio Relational thickness (100% - 13%), Belin Ambrosio enhanced ectasia display total deviation value (100% - 4%), Average pachymetric progression index (69% - 3%), Pachymetry at the thinnest point (58% - 1%), CSI Center Surround Index (100%), Differential sector index (51%). CONCLUSION The false positive rates for KC and ectatic corneal conditions vary dramatically depending on the cut-off values used. Some indexes used for diagnosis of potential ectatic corneal conditions are inaccurate in normal, highly astigmatic eyes.
Collapse
|
6
|
Optical coherence tomography of small intestine allograft biopsies using a handheld surgical probe. JOURNAL OF BIOMEDICAL OPTICS 2021; 26:JBO-210108R. [PMID: 34561973 PMCID: PMC8461564 DOI: 10.1117/1.jbo.26.9.096008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/05/2021] [Accepted: 09/08/2021] [Indexed: 06/13/2023]
Abstract
SIGNIFICANCE The current gold standard for monitoring small intestinal transplant (IT) rejection is endoscopic visual assessment and biopsy of suspicious lesions; however, these lesions are only superficially visualized by endoscopy. Invasive biopsies provide a coarse sampling of tissue health without depicting the true presence and extent of any pathology. Optical coherence tomography (OCT) presents a potential alternative approach with significant advantages over traditional white-light endoscopy. AIM The aim of our investigation was to evaluate OCT performance in distinguishing clinically relevant morphological features associated with IT graft failure. APPROACH OCT was applied to evaluate the small bowel tissues of two rhesus macaques that had undergone IT of the ileum. The traditional assessment from routine histological observation was compared with OCT captured using a handheld surgical probe during the days post-transplant and subsequently was compared with histophaology. RESULTS The reported OCT system was capable of identifying major biological landmarks in healthy intestinal tissue. Following IT, one nonhuman primate (NHP) model suffered a severe graft ischemia, and the second NHP graft failed due to acute cellular rejection. OCT images show visual evidence of correspondence with histological signs of IT rejection. CONCLUSIONS Results suggest that OCT imaging has significant potential to reveal morphological changes associated with IT rejection and to improve patient outcomes overall.
Collapse
|
7
|
Corneal immune cell morphometry as an indicator of local and systemic pathology: A review. Clin Exp Ophthalmol 2021; 49:729-740. [PMID: 34240800 DOI: 10.1111/ceo.13972] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Accepted: 07/03/2021] [Indexed: 11/26/2022]
Abstract
The corneal epithelium contains a population of resident immune cells commonly referred to as dendritic cells (DCs), or Langerhans cells. A unique advantage of the transparent cornea being situated at the surface of the eye is that these cells can be readily visualised using in vivo confocal microscopy. Over the past decade, interest in the involvement of corneal DCs in a range of ocular and systemic diseases has surged. For most studies, the number of corneal DCs has been the main outcome of interest. However, more recently attention has shifted towards understanding how DC morphology may provide insights into the inflammatory status of the cornea, and in some cases, the health of the peripheral nervous system. In this review, we provide examples of recent methodologies that have been used to classify and measure corneal DC morphology and discuss how this relates to local and systemic inflammatory conditions in humans and rodents.
Collapse
|
8
|
Handheld macroscopic Raman spectroscopy imaging instrument for machine-learning-based molecular tissue margins characterization. JOURNAL OF BIOMEDICAL OPTICS 2021; 26:JBO-200306SSR. [PMID: 33580641 PMCID: PMC7880244 DOI: 10.1117/1.jbo.26.2.022911] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/18/2020] [Accepted: 01/19/2021] [Indexed: 05/08/2023]
Abstract
SIGNIFICANCE Raman spectroscopy has been developed for surgical guidance applications interrogating live tissue during tumor resection procedures to detect molecular contrast consistent with cancer pathophysiological changes. To date, the vibrational spectroscopy systems developed for medical applications include single-point measurement probes and intraoperative microscopes. There is a need to develop systems with larger fields of view (FOVs) for rapid intraoperative cancer margin detection during surgery. AIM We design a handheld macroscopic Raman imaging system for in vivo tissue margin characterization and test its performance in a model system. APPROACH The system is made of a sterilizable line scanner employing a coherent fiber bundle for relaying excitation light from a 785-nm laser to the tissue. A second coherent fiber bundle is used for hyperspectral detection of the fingerprint Raman signal over an area of 1 cm2. Machine learning classifiers were trained and validated on porcine adipose and muscle tissue. RESULTS Porcine adipose versus muscle margin detection was validated ex vivo with an accuracy of 99% over the FOV of 95 mm2 in ∼3 min using a support vector machine. CONCLUSIONS This system is the first large FOV Raman imaging system designed to be integrated in the workflow of surgical cancer resection. It will be further improved with the aim of discriminating brain cancer in a clinically acceptable timeframe during glioma surgery.
Collapse
|
9
|
Tools and tutorial on practical ray tracing for microscopy. NEUROPHOTONICS 2021; 8:010801. [PMID: 36278783 PMCID: PMC7818000 DOI: 10.1117/1.nph.8.1.010801] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/06/2020] [Accepted: 12/18/2020] [Indexed: 06/16/2023]
Abstract
Significance: An advanced understanding of optical design is necessary to create optimal systems but this is rarely taught as part of general curriculum. Compounded by the fact that professional optical design software tools have a prohibitive learning curve, this means that neither knowledge nor tools are easily accessible. Aim: In this tutorial, we introduce a raytracing module for Python, originally developed for teaching optics with ray matrices, to simplify the design and optimization of optical systems. Approach: This module is developed for ray matrix calculations in Python. Many important concepts of optical design that are often poorly understood such as apertures, aperture stops, and field stops are illustrated. Results: The module is explained with examples in real systems with collection efficiency, vignetting, and intensity profiles. Also, the optical invariant, an important benchmark property for optical systems, is used to characterize an optical system. Conclusions: This raytracing Python module will help improve the reader's understanding of optics and also help them design optimal systems.
Collapse
|
10
|
Mapping fluorescence resonance energy transfer parameters of a bifunctional agent using time-domain fluorescence diffuse optical tomography. JOURNAL OF BIOPHOTONICS 2021; 14:e202000291. [PMID: 33025728 DOI: 10.1002/jbio.202000291] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2020] [Revised: 09/22/2020] [Accepted: 09/25/2020] [Indexed: 06/11/2023]
Abstract
We present a method to map fluorescence resonance energy transfer (FRET) parameters of a bifunctional photodynamic therapy agent, (2-[1-hexyloxyethyl]-2-devinyl pyropheophorbide-a)-cyanine dye (HPPH-CD) conjugate, which consists of a photosensitizer (HPPH) and a fluorescent agent CD. We utilized time-domain fluorescence diffuse optical tomography, the normalized Born ratio model in the Fourier-domain, and an iterative algorithm to map depth-resolved spatial heterogeneities of FRET parameters. Our results exhibited depth-resolved changes of fluorophore's lifetime and the distance maps due to FRET between HPPH and CD. Our model suggests a potential approach of using FRET parameters to monitor efficacies of multifunctional photodynamic therapy agents in deep tissue.
Collapse
|
11
|
Abstract
AIM To present a case of double anterior chamber after DALK and its surgical management. CASE DESCRIPTION A 67-year-old healthy woman underwent deep anterior lamellar keratoplasty (DALK) in her right eye for keratoconus with the big-bubble technique. About 7 days after surgery a partial detachment of the Descemet membrane from the posterior corneal stroma was revealed using AS-OCT (double anterior chamber appearance). In spite of two injections in the anterior chamber of air and gas on the 7th and 9th post-operative days respectively, the double anterior chamber still persisted. Furthermore, both air and gas passed through the little perforation of the host Descemet membrane-endothelium complex and enlarged the space between the stroma and Descemet membrane. About 10 weeks after DALK, a spontaneous resolution of the double anterior chamber was observed. CONCLUSION This case suggests that an injection of air or gas into the anterior chamber, to deal with a Descemet membrane detachment following perforation during DALK procedure, can enlarge the double anterior chamber by increasing the space between stroma and Descemet membrane. These cases can be managed with a "wait and see" strategy for a spontaneous resolution to Descemet membrane detachment.
Collapse
|
12
|
Two-photon fluorescence imaging of subsurface tissue structures with volume holographic microscopy. JOURNAL OF BIOMEDICAL OPTICS 2020; 25:JBO-200226SSR. [PMID: 33231017 PMCID: PMC7682785 DOI: 10.1117/1.jbo.25.12.123705] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/16/2020] [Accepted: 11/06/2020] [Indexed: 06/11/2023]
Abstract
SIGNIFICANCE Two-photon (2P) fluorescence imaging can provide background-free high-contrast images from the scattering tissues. However, obtaining a multiplane image is not straightforward. We present a two-photon volume holographic imaging (2P-VHI) system for multiplane imaging. AIM Our goal was to design and implement a 2P-VHI system that can provide the high-contrast optically sectioned images at multiple planes. APPROACH A 2P-VHI system is presented that incorporates angularly multiplexed volume holographic gratings and a femtosecond laser source for fluorescence excitation for multiplane imaging. A volume hologram with multiplexed gratings provides multifocal observation, whereas nonlinear excitation using a femtosecond laser helps in significantly enhancing both depth resolution and contrast of images. RESULTS Standard fluorescent beads are used to demonstrate the imaging performance of the 2P-VHI system. Two-depth resolved optical-sectioning images of fluorescently labeled thick mice intestine samples were obtained. In addition, the optical sectioning capability of our system is measured and compared with that of a conventional VHI system. CONCLUSIONS Results demonstrated that 2P excitation in VHI systems provided the optical sectioning ability that helps in reducing background noise in the images. Integration of nonlinear fluorescence excitation in the VHI provides some unique advantages to the system and has potential to design multidepth optical sectioned spatial-spectral imaging systems.
Collapse
|
13
|
A rapid white blood cell classification system based on multimode imaging technology. JOURNAL OF BIOPHOTONICS 2020; 13:e202000197. [PMID: 32696577 DOI: 10.1002/jbio.202000197] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/24/2020] [Revised: 07/10/2020] [Accepted: 07/16/2020] [Indexed: 06/11/2023]
Abstract
In order to simplify the complexity of white blood cell classification in existing point-of-care testing (POCT) testing equipment, a white blood cell classification detection system based on microfluidic and multimode imaging was constructed. Microfluidic chip was used in the system. A multimodal optical imaging system based on the characteristics of blood samples was designed to obtain eigenvalue extraction of cells. Afterward, a BP neural network model was constructed to realize automatic classification of white blood cells. Finally, 80 human blood samples were classified and detected by this system and compared with the results of Sysmex XE-5000. The consistency correlation coefficients of white blood cells, lymphocytes, monocytes, neutrophils and eosinophils are 1.038, 0.907, 0.549, 0.922 and 1.028, respectively, and the CV values of the four types of white blood cells in the stability test were all below 10%. In this study, a white blood cell classification and detection system with small size, simple operation, fast single-sample detection, high accuracy, and no maintenance is required. It will provide a solid technical support for the further development of POCT blood cell analysis equipment.
Collapse
|
14
|
Multiplane differential phase contrast imaging using asymmetric illumination in volume holographic microscopy. JOURNAL OF BIOMEDICAL OPTICS 2020; 25:JBO-200221SSR. [PMID: 33247561 PMCID: PMC7691765 DOI: 10.1117/1.jbo.25.12.123704] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/16/2020] [Accepted: 10/26/2020] [Indexed: 05/30/2023]
Abstract
SIGNIFICANCE Differential phase contrast (DPC) is a well-known imaging technique for phase imaging. However, simultaneously acquiring multidepth DPC images is a non-trivial task. We propose simultaneous multiplane DPC imaging using volume holographic microscopy (VHM). AIM To design and implement a new configuration of DPC-VHM for multiplane imaging. APPROACH The angularly multiplexed volume holographic gratings (AMVHGs) and the wavelength-coded volume holographic gratings (WC-VHGs) are used for this purpose. To obtain asymmetric illumination for DPC images, a dynamic illumination system is designed by modifying the regular Köhler illumination using a thin film transistor panel (TFT-panel). RESULTS Multidepth DPC images of standard resolution chart and biosamples were used to compare imaging performance with the corresponding bright-field images. An average contrast enhancement of around three times is observed for target resolution chart by DPC-VHM. Imaging performance of our system is studied by modulation transfer function analysis, which suggests that DPC-VHM not only suppresses the DC component but also enhances high-frequency information. CONCLUSIONS Proposed DPC-VHM can acquire multidepth-resolved DPC images without axial scanning. The illumination part of the system is adjustable so that the system can be adapted to bright-field mode, phase contrast mode, and DPC mode by controlling the pattern on the TFT-panel.
Collapse
|
15
|
Reduced fluence corneal cross-linking in mild to moderate keratoconus: One year-follow-up. Eur J Ophthalmol 2020; 31:2206-2212. [PMID: 33092399 DOI: 10.1177/1120672120966560] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
PURPOSE To evaluate the safety and efficacy of reduced fluence CXL (lower dose of UV-A irradiation) in mild to moderate keratoconus. SETTING Farabi Eye Hospital, Tehran, Iran. DESIGN Non-randomized prospective comparative interventional case series. Every eligible patient included in the study (mild to moderate progressive keratoconus) was randomly allocated to case (reduced fluence) and control (standard) groups, except for bilateral patients. In these patients the eye with more advanced disease was allocated to control group and the other eye was randomly assigned in either case or control group. Operators performing refraction and images and the data analyst were masked, but patients and physicians were not. METHODS Forty-six eyes of 38 patients were recruited. Group 1 received 7 min (fluence of 3.8 J/cm2), while group 2 received 10 min of 9 mW/cm2 UV-A (fluence of 5.4 J/cm2). Visual, keratometric and biomechanical outcomes were compared between groups. RESULTS At last follow-up (mean12 months, range 6-24 months), there were no statistically significant differences in changes in uncorrected visual acuity, best corrected distance visual acuity, Kmax, Kmean, corneal hysteresis, corneal resistance factor, endothelial cell counts, demarcation line depth, and intraoperative pain scores between groups (all p-values < 0.05). CONCLUSION The results of this study show comparable one-year outcomes between 3.8 and 5.4 J/cm2 accelerated CXL in mild to moderate keratoconus. Should the results of this study be confirmed in longer follow-ups, using a reduced fluence setting could be considered as an alternative to standard treatment in these patients.
Collapse
|
16
|
Photoacoustic topography through an ergodic relay for functional imaging and biometric application in vivo. JOURNAL OF BIOMEDICAL OPTICS 2020; 25:1-8. [PMID: 32648387 PMCID: PMC7347463 DOI: 10.1117/1.jbo.25.7.070501] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2020] [Accepted: 06/26/2020] [Indexed: 05/19/2023]
Abstract
SIGNIFICANCE Photoacoustic (PA) tomography has demonstrated versatile biomedical applications. However, an array-based PA computed tomography (PACT) system is complex and expensive, whereas a single-element detector-based scanning PA system is too slow to detect some fast biological dynamics in vivo. New PA imaging methods are sought after. AIM To overcome these limitations, we developed photoacoustic topography through an ergodic relay (PATER), a novel high-speed imaging system with a single-element detector. APPROACH PATER images widefield PA signals encoded by the acoustic ergodic relay with a single-laser shot. RESULTS We applied PATER in vivo to monitor changes in oxygen saturation in a mouse brain and also to demonstrate high-speed matching of vascular patterns for biometric authentication. CONCLUSIONS PATER has achieved a high-speed temporal resolution over a large field of view. Our results suggest that PATER is a promising and economical alternative to PACT for fast imaging.
Collapse
|
17
|
Non-invasive monitoring of pharmacodynamics during the skin wound healing process using multimodal optical microscopy. BMJ Open Diabetes Res Care 2020; 8:8/1/e000974. [PMID: 32327442 PMCID: PMC7202789 DOI: 10.1136/bmjdrc-2019-000974] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/10/2019] [Revised: 01/13/2020] [Accepted: 02/22/2020] [Indexed: 12/12/2022] Open
Abstract
OBJECTIVE Impaired diabetic wound healing is one of the serious complications associated with diabetes. In patients with diabetes, this impairment is characterized by several physiological abnormalities such as metabolic changes, reduced collagen production, and diminished angiogenesis. We designed and developed a multimodal optical imaging system that can longitudinally monitor formation of new blood vessels, metabolic changes, and collagen deposition in a non-invasive, label-free manner. RESEARCH DESIGN AND METHODS The closure of a skin wound in (db/db) mice, which presents delayed wound healing pathologically similar to conditions in human type 2 diabetes mellitus, was non-invasively followed using the custom-built multimodal microscope. In this microscope, optical coherence tomography angiography was used for studying neovascularization, fluorescence lifetime imaging microscopy for nicotinamide adenine dinucleotide (phosphate) (NAD(P)H) assessment, fluorescence intensity changes of NAD(P)H and flavin adenine dinucleotide (FAD) cofactors for evaluating metabolic changes, and second harmonic generation microscopy for analyzing collagen deposition and organization. The animals were separated into four groups: control, placebo, low concentration (LC), and high concentration (HC) treatment. Images of the wound and surrounding areas were acquired at different time points during a 28-day period. RESULTS Various physiological changes measured using the optical imaging modalities at different phases of wound healing were compared. A statistically significant improvement in the functional relationship between angiogenesis, metabolism, and structural integrity was observed in the HC group. CONCLUSIONS This study demonstrated the capability of multimodal optical imaging to non-invasively monitor various physiological aspects of the wound healing process, and thus become a promising tool in the development of better diagnostic, treatment, and monitoring strategies for diabetic wound care.
Collapse
|
18
|
Design and Fabrication of Microscale, Thin-Film Silicon Solid Immersion Lenses for Mid-Infrared Application. MICROMACHINES 2020; 11:mi11030250. [PMID: 32120857 PMCID: PMC7143082 DOI: 10.3390/mi11030250] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/30/2019] [Revised: 02/24/2020] [Accepted: 02/26/2020] [Indexed: 11/30/2022]
Abstract
Lens-based optical microscopes cannot resolve the sub-wavelength objects overpass diffraction limit. Recently, research on super-resolution imaging has been conducted to overcome this limitation in visible wavelength using solid immersion lenses. However, IR imaging, which is useful for chemical imaging, bio-imaging, and thermal imaging, has not been studied much in optical super-resolution by solid immersion lens owing to material limitations. Herein, we present the design and fabrication schemes of microscale silicon solid immersion lenses (µ-SIL) based on thin-film geometry for mid-infrared (MIR) applications. Compared with geometrical optics, a rigorous finite-difference time-domain (FDTD) calculation of proposed silicon microlenses at MIR wavelengths shows that the outstanding short focal lengths result in enhanced magnification, which allows resolving objects beyond the diffraction limit. In addition, the theoretical analyses evaluate the influences of various structural parameters, such as radius of curvature (RoC), refractive index, and substrate thickness, in µ-SIL. In particular, the high refractive index of µ-SIL is beneficial to implement the outstanding near-field focusing, which corresponds to a high numerical aperture. On the basis of this theoretical background, novel methods are developed for the fabrication of a printable, thin-film silicon microlens array and its integration with a specimen substrate. From the result, we provide a physical understanding of near-field focusing phenomena and offer a promising tool for super-resolution far-field imaging in the MIR range.
Collapse
|
19
|
Propagating-path uniformly scanned light sheet excitation microscopy for isotropic volumetric imaging of large specimens. JOURNAL OF BIOMEDICAL OPTICS 2019; 24:1-5. [PMID: 31385482 PMCID: PMC6983483 DOI: 10.1117/1.jbo.24.8.086501] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/04/2019] [Accepted: 07/15/2019] [Indexed: 05/26/2023]
Abstract
We demonstrate a propagating-path uniformly scanned light sheet excitation (PULSE) microscopy based on the oscillation of voice coil motor that can rapidly drive a thin light sheet along its propagation direction. By synchronizing the rolling shutter of a camera with the motion of laser sheet, we can obtain a uniform plane-illuminated image far beyond the confocal range of Gaussian beam. A stable 1.7-μm optical sectioning under a 3.3 mm × 3.3 mm wide field of view (FOV) has been achieved for up to 20 Hz volumetric imaging of large biological specimens. PULSE method transforms the extent of plane illumination from one intrinsically limited by the short confocal range (μm scale) to one defined by the motor oscillation range (mm scale). Compared to the conventional Gaussian light sheet imaging, our method greatly mitigates the compromise of axial resolution and successfully extends the FOV over 100 times. We demonstrate the applications of PULSE method by rapidly imaging cleared mouse spinal cord and live zebrafish larva at isotropic subcellular resolution.
Collapse
|
20
|
Combined ultrasound and photoacoustic imaging of blood clot during microbubble-assisted sonothrombolysis. JOURNAL OF BIOMEDICAL OPTICS 2019; 24:1-8. [PMID: 31342692 PMCID: PMC7005573 DOI: 10.1117/1.jbo.24.12.121902] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/10/2019] [Accepted: 06/12/2019] [Indexed: 05/06/2023]
Abstract
Blockage of healthy blood vessels by blood clots can lead to serious or even life-threatening complications. The use of a combined ultrasound (US) and photoacoustic (PA) imaging was explored for blood clot monitoring during microbubble-assisted sonothrombolysis. PA imaging is an emerging hybrid imaging modality that has garnered the attention of the biomedical imaging community in recent years. It enables the study of the composition of a blood clot due to its sensitivity toward optical absorption. Here, in vitro imaging of the side of a blood clot facing the microbubbles was done over time. The US and PA signal-to-noise (SNR) ratio value changes during microbubble-assisted sonothrombolysis were studied for two different local environments: blood clot in deionized water and blood clot in blood. In the first case, US and PA SNR values increased by 4.6% and reduced by 20.8%, respectively after 30 min of sonothrombolysis treatment. After 10 min of sonothrombolysis treatment of the blood clot in blood, the US and PA SNR values increased by 7.7% and 38.3%, respectively. The US and PA SNR value changes were recorded in response to its local environment. This technique can be used to determine the final composition of the blood clot which may, in turn, help in the administration of clot-dissolving drugs.
Collapse
|
21
|
Extracting individual neural activity recorded through splayed optical microfibers. NEUROPHOTONICS 2018; 5:045009. [PMID: 30627593 PMCID: PMC6311456 DOI: 10.1117/1.nph.5.4.045009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/02/2018] [Accepted: 11/28/2018] [Indexed: 06/01/2023]
Abstract
Previously introduced bundles of hundreds or thousands of microfibers have the potential to extend optical access to deep brain regions, sampling fluorescence activity throughout a three-dimensional volume. Each fiber has a small diameter ( 8 μ m ) and follows a path of least resistance, splaying during insertion. By superimposing the fiber sensitivity profile for each fiber, we model the interface properties for a simulated neural population. Our modeling results suggest that for small ( < 200 ) bundles of fibers, each fiber will collect fluorescence from a small number of nonoverlapping neurons near the fiber apertures. As the number of fibers increases, the bundle delivers more uniform excitation power to the region, moving to a regime where fibers collect fluorescence from more neurons and there is greater overlap between neighboring fibers. Under these conditions, it becomes feasible to apply source separation to extract individual neural contributions. In addition, we demonstrate a source separation technique particularly suited to the interface. Our modeling helps establish performance expectations for this interface and provides a framework for estimating neural contributions under a range of conditions.
Collapse
|
22
|
Adaptation of microscopy with ultraviolet surface excitation for enhancing STEM and undergraduate education. JOURNAL OF BIOMEDICAL OPTICS 2018; 23:1-8. [PMID: 30054996 DOI: 10.1117/1.jbo.23.12.121603] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/17/2018] [Accepted: 06/08/2018] [Indexed: 06/08/2023]
Abstract
Microscopy with ultraviolet surface excitation (MUSE) is investigated as a means to enhance curricula and education in the life sciences based on simplicity of use, the incorporation of inexpensive hardware, and the simplest methods of tissue preparation. Ultraviolet excitation in effect replaces tissue sectioning because it penetrates only a few micrometers below the tissue surface at the single cell level, preventing the generation of out-of-focus light. Although tissue autofluorescence may be used, image quality and content can be enhanced by a brief immersion in a solution of nontoxic fluorescent dyes that selectively highlight different cellular compartments. Safe mixed-dye powder combinations have been developed to provide students who have minimal lab proficiencies with a one-step tissue staining process for rapid tissue preparation.
Collapse
|
23
|
Advances in Carbon Nanotubes-Hydrogel Hybrids in Nanomedicine for Therapeutics. Adv Healthc Mater 2018; 7:e1701213. [PMID: 29388356 PMCID: PMC6248342 DOI: 10.1002/adhm.201701213] [Citation(s) in RCA: 87] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2017] [Revised: 11/21/2017] [Indexed: 12/21/2022]
Abstract
In spite of significant advancement in hydrogel technology, low mechanical strength and lack of electrical conductivity have limited their next-level biomedical applications for skeletal muscles, cardiac and neural cells. Host-guest chemistry based hybrid nanocomposites systems have gained attention as they completely overcome these pitfalls and generate bioscaffolds with tunable electrical and mechanical characteristics. In recent years, carbon nanotube (CNT)-based hybrid hydrogels have emerged as innovative candidates with diverse applications in regenerative medicines, tissue engineering, drug delivery devices, implantable devices, biosensing, and biorobotics. This article is an attempt to recapitulate the advancement in synthesis and characterization of hybrid hydrogels and provide deep insights toward their functioning and success as biomedical devices. The improved comparative performance and biocompatibility of CNT-hydrogels hybrids systems developed for targeted biomedical applications are addressed here. Recent updates toward diverse applications and limitations of CNT hybrid hydrogels is the strength of the review. This will provide a holistic approach toward understanding of CNT-based hydrogels and their applications in nanotheranostics.
Collapse
|
24
|
Spectrally encoded coherence tomography and reflectometry: Simultaneous en face and cross-sectional imaging at 2 gigapixels per second. JOURNAL OF BIOPHOTONICS 2018; 11:e201700268. [PMID: 29149542 PMCID: PMC5903931 DOI: 10.1002/jbio.201700268] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/19/2017] [Accepted: 11/10/2017] [Indexed: 05/18/2023]
Abstract
Non-invasive biological imaging is crucial for understanding in vivo structure and function. Optical coherence tomography (OCT) and reflectance confocal microscopy are two of the most widely used optical modalities for exogenous contrast-free, high-resolution, three-dimensional imaging in non-fluorescent scattering tissues. However, sample motion remains a critical barrier to raster-scanned acquisition and reconstruction of wide-field anatomically accurate volumetric datasets. We introduce spectrally encoded coherence tomography and reflectometry (SECTR), a high-speed, multimodality system for simultaneous OCT and spectrally encoded reflectance (SER) imaging. SECTR utilizes a robust system design consisting of shared optical relays, scanning mirrors, swept laser and digitizer to achieve the fastest reported in vivo multimodal imaging rate of 2 gigapixels per second. Our optical design and acquisition scheme enable spatiotemporally co-registered acquisition of OCT cross-sections simultaneously with en face SER images for multivolumetric mosaicking. Complementary axial and lateral translation and rotation are extracted from OCT and SER data, respectively, for full volumetric estimation of sample motion with micron spatial and millisecond temporal resolution.
Collapse
|
25
|
Spectrally encoded coherence tomography and reflectometry: Simultaneous en face and cross-sectional imaging at 2 gigapixels per second. JOURNAL OF BIOPHOTONICS 2018; 11:e201700268. [PMID: 29149542 DOI: 10.1002/jbio.2018.11.issue-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/19/2017] [Accepted: 11/10/2017] [Indexed: 05/22/2023]
Abstract
Non-invasive biological imaging is crucial for understanding in vivo structure and function. Optical coherence tomography (OCT) and reflectance confocal microscopy are two of the most widely used optical modalities for exogenous contrast-free, high-resolution, three-dimensional imaging in non-fluorescent scattering tissues. However, sample motion remains a critical barrier to raster-scanned acquisition and reconstruction of wide-field anatomically accurate volumetric datasets. We introduce spectrally encoded coherence tomography and reflectometry (SECTR), a high-speed, multimodality system for simultaneous OCT and spectrally encoded reflectance (SER) imaging. SECTR utilizes a robust system design consisting of shared optical relays, scanning mirrors, swept laser and digitizer to achieve the fastest reported in vivo multimodal imaging rate of 2 gigapixels per second. Our optical design and acquisition scheme enable spatiotemporally co-registered acquisition of OCT cross-sections simultaneously with en face SER images for multivolumetric mosaicking. Complementary axial and lateral translation and rotation are extracted from OCT and SER data, respectively, for full volumetric estimation of sample motion with micron spatial and millisecond temporal resolution.
Collapse
|
26
|
Multicontrast endomyocardial imaging by single-channel high-resolution cross-polarization optical coherence tomography. JOURNAL OF BIOPHOTONICS 2018; 11:e201700204. [PMID: 29165902 PMCID: PMC6186148 DOI: 10.1002/jbio.201700204] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/02/2017] [Revised: 11/19/2017] [Accepted: 11/20/2017] [Indexed: 05/10/2023]
Abstract
A single-channel high-resolution cross-polarization (CP) optical coherence tomography (OCT) system is presented for multicontrast imaging of human myocardium in one-shot measurement. The intensity and functional contrasts, including the ratio between the cross- and co-polarization channels as well as the cumulative retardation, are reconstructed from the CP-OCT readout. By comparing the CP-OCT results with histological analysis, it is shown that the system can successfully delineate microstructures in the myocardium and differentiate the fibrotic myocardium from normal or ablated myocardium based on the functional contrasts provided by the CP-OCT system. The feasibility of using A-line profiles from the 2 orthogonal polarization channels to identify fibrotic myocardium, normal myocardium and ablated lesion is also discussed.
Collapse
|
27
|
Flexible wide-field optical micro-angiography based on Fourier-domain multiplexed dual-beam swept source optical coherence tomography. JOURNAL OF BIOPHOTONICS 2018; 11:10.1002/jbio.201700203. [PMID: 28941235 PMCID: PMC5839934 DOI: 10.1002/jbio.201700203] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2017] [Revised: 09/13/2017] [Accepted: 09/14/2017] [Indexed: 05/19/2023]
Abstract
Wide-field optical coherence tomography angiography (OCTA) is gaining interest in clinical imaging applications. In this pursuit, it is challenging to maintain the imaging resolution and sensitivity throughout the wide field of view (FoV). Here, we propose a novel method/system of dual-beam arrangement and Fourier-domain multiplexing to achieve wide-field OCTA when imaging the uneven surface samples. The proposed system provides 2 separate FoVs, with flexibility that the imaging area, focus of the imaging beam and imaging depth range can be individually adjusted for each FoV, leading to either (1) increased system imaging FoV or (2) capability of targeting 2 regions of interests that locate at depths with large difference between each other. We demonstrate this novel method by employing 100 kHz laser source in a swept source OCTA to achieve an effective 200 kHz sweeping rate, covering a 22 × 22 mm FoV. The results are verified by a SS-OCTA system employing a 200 kHz laser source, together with the experimental demonstrations when imaging whole brain vasculature in rodent models and skin blood perfusion in human fingers, show-casing the capability of proposed system to image live large samples with complex surface topography.
Collapse
|
28
|
Long ranging swept-source optical coherence tomography-based angiography outperforms its spectral-domain counterpart in imaging human skin microcirculations. JOURNAL OF BIOMEDICAL OPTICS 2017; 22:1-11. [PMID: 29185292 PMCID: PMC5712670 DOI: 10.1117/1.jbo.22.11.116007] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/14/2017] [Accepted: 11/08/2017] [Indexed: 05/07/2023]
Abstract
There is an increasing demand for imaging tools in clinical dermatology that can perform in vivo wide-field morphological and functional examination from surface to deep tissue regions at various skin sites of the human body. The conventional spectral-domain optical coherence tomography-based angiography (SD-OCTA) system is difficult to meet these requirements due to its fundamental limitations of the sensitivity roll-off, imaging range as well as imaging speed. To mitigate these issues, we demonstrate a swept-source OCTA (SS-OCTA) system by employing a swept source based on a vertical cavity surface-emitting laser. A series of comparisons between SS-OCTA and SD-OCTA are conducted. Benefiting from the high system sensitivity, long imaging range, and superior roll-off performance, the SS-OCTA system is demonstrated with better performance in imaging human skin than the SD-OCTA system. We show that the SS-OCTA permits remarkable deep visualization of both structure and vasculature (up to ∼2 mm penetration) with wide field of view capability (up to 18×18 mm2), enabling a more comprehensive assessment of the morphological features as well as functional blood vessel networks from the superficial epidermal to deep dermal layers. It is expected that the advantages of the SS-OCTA system will provide a ground for clinical translation, benefiting the existing dermatological practice.
Collapse
|
29
|
Structural and functional imaging of aqueous humour outflow: a review. Clin Exp Ophthalmol 2017; 46:158-168. [PMID: 28898516 DOI: 10.1111/ceo.13064] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2017] [Accepted: 09/06/2017] [Indexed: 01/15/2023]
Abstract
Maintaining healthy aqueous humour outflow (AHO) is important for intraocular cellular health and stable vision. Impairment of AHO can lead to increased intraocular pressure, optic nerve damage and concomitant glaucoma. An improved understanding of AHO will lead to improved glaucoma surgeries that enhance native AHO as well as facilitate the development of AHO-targeted pharmaceuticals. Recent AHO imaging has evolved to live human assessment and has focused on the structural evaluation of AHO pathways and the functional documentation of fluid flow. Structural AHO evaluation is predominantly driven by optical coherence tomography, and functional evaluation of flow is performed using various methods, including aqueous angiography. Advances in structural and functional evaluation of AHO are reviewed with discussion of strengths, weaknesses and potential future directions.
Collapse
|
30
|
Photoacoustic imaging of lymphatic pumping. JOURNAL OF BIOMEDICAL OPTICS 2017; 22:1-6. [PMID: 29022300 DOI: 10.1117/1.jbo.22.10.106003] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2017] [Accepted: 08/15/2017] [Indexed: 05/21/2023]
Abstract
The lymphatic system is responsible for fluid homeostasis and immune cell trafficking and has been implicated in several diseases, including obesity, diabetes, and cancer metastasis. Despite its importance, the lack of suitable in vivo imaging techniques has hampered our understanding of the lymphatic system. This is, in part, due to the limited contrast of lymphatic fluids and structures. Photoacoustic imaging, in combination with optically absorbing dyes or nanoparticles, has great potential for noninvasively visualizing the lymphatic vessels deep in tissues. Multispectral photoacoustic imaging is capable of separating the components; however, the slow wavelength switching speed of most laser systems is inadequate for imaging lymphatic pumping without motion artifacts being introduced into the processed images. We investigate two approaches for visualizing lymphatic processes in vivo. First, single-wavelength differential photoacoustic imaging is used to visualize lymphatic pumping in the hindlimb of a mouse in real time. Second, a fast-switching multiwavelength photoacoustic imaging system was used to assess the propulsion profile of dyes through the lymphatics in real time. These approaches may have profound impacts in noninvasively characterizing and investigating the lymphatic system.
Collapse
|
31
|
Preclinical imaging of iridocorneal angle and fundus using a modified integrated flexible handheld probe. J Med Imaging (Bellingham) 2017; 4:026001. [PMID: 28413809 DOI: 10.1117/1.jmi.4.2.026001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2017] [Accepted: 03/21/2017] [Indexed: 11/14/2022] Open
Abstract
A flexible handheld imaging probe consisting of a [Formula: see text] charge-coupled device camera, light-emitting diode light sources, and near-infrared laser source is designed and developed. The imaging probe is designed with specifications to capture the iridocorneal angle images and posterior segment images. Light propagation from the anterior chamber of the eye to the exterior is considered analytically using Snell's law. Imaging of the iridocorneal angle region and fundus is performed on ex vivo porcine samples and subsequently on small laboratory animals, such as the New Zealand white rabbit and nonhuman primate, in vivo. The integrated flexible handheld probe demonstrates high repeatability in iridocorneal angle and fundus documentation. The proposed concept and methodology are expected to find potential application in the diagnosis, prognosis, and management of glaucoma.
Collapse
|
32
|
Astigmatism corrected common path probe for optical coherence tomography. Lasers Surg Med 2016; 49:312-318. [PMID: 27490964 DOI: 10.1002/lsm.22554] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/16/2016] [Indexed: 02/03/2023]
Abstract
BACKGROUND AND OBJECTIVES Optical coherence tomography (OCT) catheters for intraluminal imaging are subject to various artifacts due to reference-sample arm dispersion imbalances and sample arm beam astigmatism. The goal of this work was to develop a probe that minimizes such artifacts. MATERIALS AND METHODS Our probe was fabricated using a single mode fiber at the tip of which a glass spacer and graded index objective lens were spliced to achieve the desired focal distance. The signal was reflected using a curved reflector to correct for astigmatism caused by the thin, protective, transparent sheath that surrounds the optics. The probe design was optimized using Zemax, a commercially available optical design software. Common path interferometric operation was achieved using Fresnel reflection from the tip of the focusing graded index objective lens. The performance of the probe was tested using a custom designed spectrometer-based OCT system. RESULTS The probe achieved an axial resolution of 15.6 μm in air, a lateral resolution 33 μm, and a sensitivity of 103 dB. A scattering tissue phantom was imaged to test the performance of the probe for astigmatism correction. Images of the phantom confirmed that this common-path, astigmatism-corrected OCT imaging probe had minimal artifacts in the axial, and lateral dimensions. CONCLUSIONS In this work, we developed an astigmatism-corrected, common path probe that minimizes artifacts associated with standard OCT probes. This design may be useful for OCT applications that require high axial and lateral resolutions. Lasers Surg. Med. 49:312-318, 2017. © 2016 Wiley Periodicals, Inc.
Collapse
|
33
|
The engineered eyeball, a tunable imaging system using soft-matter micro-optics. LIGHT, SCIENCE & APPLICATIONS 2016; 5:e16068. [PMID: 30167172 PMCID: PMC6059944 DOI: 10.1038/lsa.2016.68] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/15/2015] [Revised: 01/05/2016] [Accepted: 01/06/2016] [Indexed: 06/08/2023]
Abstract
We demonstrate a tunable imaging system based on the functionality of the mammalian eye using soft-matter micro-optical components. Inspired by the structure of the eye, as well as by the means through which nature tunes its optical behavior, we show that the technologies of microsystems engineering and micro-optics may be used to realize a technical imaging system whose biomimetic functionality is entirely distinct from that of conventional optics. The engineered eyeball integrates a deformable elastomeric refractive structure whose shape is mechanically controlled through application of strain using liquid crystal elastomer (LCE) actuators; two forms of tunable iris, one based on optofluidics and the other on LCEs with embedded heaters; a fixed lens arrangement; and a commercial imaging sensor chip. The complete microsystem, optimized to yield optical characteristics close to those of the human eye, represents the first fully functional, soft-matter-based tunable single-aperture eye-like imager.
Collapse
|
34
|
Coregistered photoacoustic and ultrasound imaging and classification of ovarian cancer: ex vivo and in vivo studies. JOURNAL OF BIOMEDICAL OPTICS 2016; 21:46006. [PMID: 27086690 PMCID: PMC4833884 DOI: 10.1117/1.jbo.21.4.046006] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/05/2015] [Accepted: 03/24/2016] [Indexed: 05/20/2023]
Abstract
Most ovarian cancers are diagnosed at advanced stages due to the lack of efficacious screening techniques. Photoacoustic tomography (PAT) has a potential to image tumor angiogenesis and detect early neovascular changes of the ovary. We have developed a coregistered PAT and ultrasound (US) prototype system for real-time assessment of ovarian masses. Features extracted from PAT and US angular beams, envelopes, and images were input to a logistic classifier and a support vector machine (SVM) classifier to diagnose ovaries as benign or malignant. A total of 25 excised ovaries of 15 patients were studied and the logistic and SVM classifiers achieved sensitivities of 70.4 and 87.7%, and specificities of 95.6 and 97.9%, respectively. Furthermore, the ovaries of two patients were noninvasively imaged using the PAT/US system before surgical excision. By using five significant features and the logistic classifier, 12 out of 14 images (86% sensitivity) from a malignant ovarian mass and all 17 images (100% specificity) from a benign mass were accurately classified; the SVM correctly classified 10 out of 14 malignant images (71% sensitivity) and all 17 benign images (100% specificity). These initial results demonstrate the clinical potential of the PAT/US technique for ovarian cancer diagnosis.
Collapse
|
35
|
Live Imaging of Cellular Internalization of Single Colloidal Particle by Combined Label-Free and Fluorescence Total Internal Reflection Microscopy. Mol Pharm 2015; 12:3862-70. [PMID: 26402436 DOI: 10.1021/acs.molpharmaceut.5b00215] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
In this work we utilize the combination of label-free total internal reflection microscopy and total internal reflectance fluorescence (TIRM/TIRF) microscopy to achieve a simultaneous, live imaging of single, label-free colloidal particle endocytosis by individual cells. The TIRM arm of the microscope enables label free imaging of the colloid and cell membrane features, while the TIRF arm images the dynamics of fluorescent-labeled clathrin (protein involved in endocytosis via clathrin pathway), expressed in transfected 3T3 fibroblasts cells. Using a model polymeric colloid and cells with a fluorescently tagged clathrin endocytosis pathway, we demonstrate that wide field TIRM/TIRF coimaging enables live visualization of the process of colloidal particle interaction with the labeled cell structure, which is valuable for discerning the membrane events and route of colloid internalization by the cell. We further show that 500 nm in diameter model polystyrene colloid associates with clathrin, prior to and during its cellular internalization. This association is not apparent with larger, 1 μm in diameter colloids, indicating an upper particle size limit for clathrin-mediated endocytosis.
Collapse
|
36
|
Compact wearable dual-mode imaging system for real-time fluorescence image-guided surgery. JOURNAL OF BIOMEDICAL OPTICS 2015; 20:096010. [PMID: 26358823 PMCID: PMC4689107 DOI: 10.1117/1.jbo.20.9.096010] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/10/2015] [Accepted: 08/10/2015] [Indexed: 06/05/2023]
Abstract
A wearable all-plastic imaging system for real-time fluorescence image-guided surgery is presented. The compact size of the system is especially suitable for applications in the operating room. The system consists of a dual-mode imaging system, see-through goggle, autofocusing, and auto-contrast tuning modules. The paper will discuss the system design and demonstrate the system performance.
Collapse
|
37
|
GLO-Roots: an imaging platform enabling multidimensional characterization of soil-grown root systems. eLife 2015; 4:e07597. [PMID: 26287479 PMCID: PMC4589753 DOI: 10.7554/elife.07597] [Citation(s) in RCA: 144] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2015] [Accepted: 08/18/2015] [Indexed: 12/16/2022] Open
Abstract
Root systems develop different root types that individually sense cues from their local environment and integrate this information with systemic signals. This complex multi-dimensional amalgam of inputs enables continuous adjustment of root growth rates, direction, and metabolic activity that define a dynamic physical network. Current methods for analyzing root biology balance physiological relevance with imaging capability. To bridge this divide, we developed an integrated-imaging system called Growth and Luminescence Observatory for Roots (GLO-Roots) that uses luminescence-based reporters to enable studies of root architecture and gene expression patterns in soil-grown, light-shielded roots. We have developed image analysis algorithms that allow the spatial integration of soil properties, gene expression, and root system architecture traits. We propose GLO-Roots as a system that has great utility in presenting environmental stimuli to roots in ways that evoke natural adaptive responses and in providing tools for studying the multi-dimensional nature of such processes.
Collapse
|
38
|
In vivo volumetric depth-resolved vasculature imaging of human limbus and sclera with 1 μm swept source phase-variance optical coherence angiography. JOURNAL OF OPTICS (2010) 2015; 17:065301. [PMID: 25984290 PMCID: PMC4429254 DOI: 10.1088/2040-8978/17/6/065301] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
We present nnnnnin vivo volumetric depth-resolved vasculature images of the anterior segment of the human eye acquired with phase-variance based motion contrast using a high-speed (100 kHz, 105 A-scans/s) swept source optical coherence tomography system (SSOCT). High phase stability SSOCT imaging was achieved by using a computationally efficient phase stabilization approach. The human corneo-scleral junction and sclera were imaged with swept source phase-variance optical coherence angiography and compared with slit lamp images from the same eyes of normal subjects. Different features of the rich vascular system in the conjunctiva and episclera were visualized and described. This system can be used as a potential tool for ophthalmological research to determine changes in the outflow system, which may be helpful for identification of abnormalities that lead to glaucoma.
Collapse
|
39
|
Simultaneous dual-color fluorescence microscope: a characterization study. ANALYTICAL CELLULAR PATHOLOGY (AMSTERDAM) 2014; 36:163-72. [PMID: 24844533 PMCID: PMC4605718 DOI: 10.3233/acp-140089] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Background: High spatial resolution and geometric accuracy is crucial for chromosomal analysis of clinical cytogenetic applications. High resolution and rapid simultaneous acquisition of multiple fluorescent wavelengths can be achieved by utilizing concurrent imaging with multiple detectors. However, such class of microscopic systems functions differently from traditional fluorescence microscopes. Objective: To develop a practical characterization framework to assess and optimize the performance of a high resolution and dual-color fluorescence microscope designed for clinical chromosomal analysis. Methods: A dual-band microscopic imaging system utilizes a dichroic mirror, two sets of specially selected optical filters, and two detectors to simultaneously acquire two fluorescent wavelengths. The system’s geometric distortion, linearity, the modulation transfer function, and the dual detectors’ alignment were characterized. Results: Experiment results show that the geometric distortion at lens periphery is less than 1%. Both fluorescent channels show linear signal responses, but there exists discrepancy between the two due to the detectors’ non-uniform response ratio to different wavelengths. In terms of the spatial resolution, the two contrast transfer function curves trend agreeably with the spatial frequency. The alignment measurement allows quantitatively assessing the cameras' alignment. A result image of adjusted alignment is demonstrated to show the reduced discrepancy by using the alignment measurement method. Conclusions: In this paper, we present a system characterization study and its methods for a specially designed imaging system for clinical cytogenetic applications. The presented characterization methods are not only unique to this dual-color imaging system but also applicable to evaluation and optimization of other similar multi-color microscopic image systems for improving their clinical utilities for future cytogenetic applications.
Collapse
|
40
|
A fast color image enhancement algorithm based on Max Intensity Channel. JOURNAL OF MODERN OPTICS 2014; 61:466-477. [PMID: 25110395 PMCID: PMC4125365 DOI: 10.1080/09500340.2014.897387] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
In this paper, we extend image enhancement techniques based on the retinex theory imitating human visual perception of scenes containing high illumination variations. This extension achieves simultaneous dynamic range modification, color consistency, and lightness rendition without multi-scale Gaussian filtering which has a certain halo effect. The reflection component is analyzed based on the illumination and reflection imaging model. A new prior named Max Intensity Channel (MIC) is implemented assuming that the reflections of some points in the scene are very high in at least one color channel. Using this prior, the illumination of the scene is obtained directly by performing a gray-scale closing operation and a fast cross-bilateral filtering on the MIC of the input color image. Consequently, the reflection component of each RGB color channel can be determined from the illumination and reflection imaging model. The proposed algorithm estimates the illumination component which is relatively smooth and maintains the edge details in different regions. A satisfactory color rendition is achieved for a class of images that do not satisfy the gray-world assumption implicit to the theoretical foundation of the retinex. Experiments are carried out to compare the new method with several spatial and transform domain methods. Our results indicate that the new method is superior in enhancement applications, improves computation speed, and performs well for images with high illumination variations than other methods. Further comparisons of images from National Aeronautics and Space Administration and a wearable camera eButton have shown a high performance of the new method with better color restoration and preservation of image details.
Collapse
|
41
|
Hybrid photomultiplier tube and photodiode parallel detection array for wideband optical spectroscopy of the breast guided by magnetic resonance imaging. JOURNAL OF BIOMEDICAL OPTICS 2014; 19:011010. [PMID: 23979460 PMCID: PMC3909491 DOI: 10.1117/1.jbo.19.1.011010] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/26/2013] [Revised: 06/25/2013] [Accepted: 07/22/2013] [Indexed: 05/18/2023]
Abstract
A new optical parallel detection system of hybrid frequency and continuous-wave domains was developed to improve the data quality and accuracy in recovery of all breast optical properties. This new system was deployed in a previously existing system for magnetic resonance imaging (MRI)-guided spectroscopy, and allows incorporation of additional near-infrared wavelengths beyond 850 nm, with interlaced channels of photomultiplier tubes (PMTs) and silicon photodiodes (PDs). The acquisition time for obtaining frequency-domain data at six wavelengths (660, 735, 785, 808, 826, and 849 nm) and continuous-wave data at three wavelengths (903, 912, and 948 nm) is 12 min. The dynamic ranges of the detected signal are 105 and 106 for PMT and PD detectors, respectively. Compared to the previous detection system, the SNR ratio of frequency-domain detection was improved by nearly 103 through the addition of an RF amplifier and the utilization of programmable gain. The current system is being utilized in a clinical trial imaging suspected breast cancer tumors as detected by contrast MRI scans.
Collapse
|
42
|
Lateral and axial measurement differences between spectral-domain optical coherence tomography systems. JOURNAL OF BIOMEDICAL OPTICS 2014; 19:16014. [PMID: 24441877 PMCID: PMC3894429 DOI: 10.1117/1.jbo.19.1.016014] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/22/2013] [Revised: 12/12/2013] [Accepted: 12/16/2013] [Indexed: 06/03/2023]
Abstract
We assessed the reproducibility of lateral and axial measurements performed with spectral-domain optical coherence tomography (SDOCT) instruments from a single manufacturer and across several manufacturers. One human retina phantom was imaged on two instruments each from four SDOCT platforms: Zeiss Cirrus, Heidelberg Spectralis, Bioptigen SDOIS, and hand-held Bioptigen Envisu. Built-in software calipers were used to perform manual measurements of a fixed lateral width (LW), central foveal thickness (CFT), and parafoveal thickness (PFT) 1 mm from foveal center. Inter- and intraplatform reproducibilities were assessed with analysis of variance and Tukey-Kramer tests. The range of measurements between platforms was 5171 to 5290 μm for mean LW (p<0.001), 162 to 196 μm for mean CFT (p<0.001), and 267 to 316 μm for mean PFT (p<0.001). All SDOCT platforms had significant differences between each other for all measurements, except LW between Bioptigen SDOIS and Envisu (p=0.27). Intraplatform differences were significantly smaller than interplatform differences for LW (p=0.020), CFT (p=0.045), and PFT (p=0.004). Conversion factors were generated for lateral and axial scaling between SDOCT platforms. Lateral and axial manual measurements have greater variance across different SDOCT platforms than between instruments from the same platform. Conversion factors for measurements from different platforms can produce normalized values for patient care and clinical studies.
Collapse
|
43
|
Assessing near infrared optical properties of ceramic orthodontic brackets using cross-polarization optical coherence tomography. J Biomed Mater Res B Appl Biomater 2013; 102:516-23. [PMID: 24106170 DOI: 10.1002/jbm.b.33029] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2013] [Revised: 07/24/2013] [Accepted: 08/18/2013] [Indexed: 11/05/2022]
Abstract
Secondary decay (caries) under ceramic orthodontic brackets remains a significant dental problem and near infrared cross-polarization optical coherence tomography (CP-OCT) has the potential to detect underlying demineralization. The purpose of this study was to determine the effect of crystalline structure and chemical composition of ceramic brackets on CP-OCT imaging. Four ceramic brackets types, which were divided into monocrystalline and polycrystalline, were examined using CP-OCT. The results of this study demonstrated that the crystallinity of the ceramic brackets affected the 1310 nm CP-OCT imaging with the greatest attenuation seen in polycrystalline alumina brackets. The alumina polycrystalline bracket materials had significantly higher attenuation and scattering than alumina monocrystalline brackets (p < 0.05, ANOVA, Bonferroni). Additionally, bracket base morphology and composition affected NIR light attenuation. There was considerable attenuation in bracket bases that contained additive zirconium spheres (∼30 µm) and this alteration was significantly greater than the jagged alumina crystallographic alterations found in the other bracket systems (p < 0.05, ANOVA, Bonferroni). Noninvasive, near infrared (NIR) cross-polarization optical coherence tomography (CP-OCT) has potential to effectively image through portions of ceramic brackets; however, further investigation into the optical effects of resin integration in the base portion of the brackets is warranted.
Collapse
|
44
|
A Multi-Camera System for Bioluminescence Tomography in Preclinical Oncology Research. Diagnostics (Basel) 2013; 3:325-43. [PMID: 26824926 PMCID: PMC4665465 DOI: 10.3390/diagnostics3030325] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2013] [Revised: 06/13/2013] [Accepted: 06/26/2013] [Indexed: 01/11/2023] Open
Abstract
Bioluminescent imaging (BLI) of cells expressing luciferase is a valuable noninvasive technique for investigating molecular events and tumor dynamics in the living animal. Current usage is often limited to planar imaging, but tomographic imaging can enhance the usefulness of this technique in quantitative biomedical studies by allowing accurate determination of tumor size and attribution of the emitted light to a specific organ or tissue. Bioluminescence tomography based on a single camera with source rotation or mirrors to provide additional views has previously been reported. We report here in vivo studies using a novel approach with multiple rotating cameras that, when combined with image reconstruction software, provides the desired representation of point source metastases and other small lesions. Comparison with MRI validated the ability to detect lung tumor colonization in mouse lung.
Collapse
|
45
|
Diffuse optical tomography in the presence of a chest wall. JOURNAL OF BIOMEDICAL OPTICS 2013; 18:26016. [PMID: 23392384 PMCID: PMC3566530 DOI: 10.1117/1.jbo.18.2.026016] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/08/2012] [Revised: 12/07/2012] [Accepted: 01/14/2013] [Indexed: 06/01/2023]
Abstract
Diffuse optical tomography (DOT) has been employed to derive spatial maps of physiologically important chromophores in the human breast, but the fidelity of these images is often compromised by boundary effects such as those due to the chest wall. We explore the image quality in fast, data-intensive analytic and algebraic linear DOT reconstructions of phantoms with subcentimeter target features and large absorptive regions mimicking the chest wall. Experiments demonstrate that the chest wall phantom can introduce severe image artifacts. We then show how these artifacts can be mitigated by exclusion of data affected by the chest wall. We also introduce and demonstrate a linear algebraic reconstruction method well suited for very large data sets in the presence of a chest wall.
Collapse
|
46
|
Three-dimensional imaging of normal skin and nonmelanoma skin cancer with cellular resolution using Gabor domain optical coherence microscopy. JOURNAL OF BIOMEDICAL OPTICS 2012; 17:126006. [PMID: 23208217 PMCID: PMC3512165 DOI: 10.1117/1.jbo.17.12.126006] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/30/2012] [Revised: 10/20/2012] [Accepted: 10/31/2012] [Indexed: 05/22/2023]
Abstract
We investigate morphological differences in three-dimensional (3-D) images with cellular resolution between nonmelanoma skin cancer and normal skin using Gabor domain optical coherence microscopy. As a result, we show for the first time cellular optical coherence images of 3-D features differentiating cancerous skin from normal skin. In addition, in vivo volumetric images of normal skin from different anatomic locations are shown and compared.
Collapse
|
47
|
Complex conjugate artifact-free adaptive optics optical coherence tomography of in vivo human optic nerve head. JOURNAL OF BIOMEDICAL OPTICS 2012. [PMID: 23208216 PMCID: PMC3512164 DOI: 10.1117/1.jbo.17.12.126005] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
We acquired in vivo images of the human optic nerve head (ONH) using an adaptive optics-optical coherence tomography (AO-OCT) system. In order to improve imaging of the lamina cribrosa in the ONH with high lateral resolution and sensitivity, we implemented a complex conjugate artifact-free Fourier domain OCT (Fd-OCT) acquisition scheme with a reference arm-based phase shifting method. This allowed positioning of the lamina cribrosa structures near the zero path length difference where AO-OCT imaging achieves highest sensitivity. Implementation of our complex conjugate artifact removal (CCR) method required constant phase shifts between consecutive axial scans (A-scans), generated by continuous beam path-length changes from offsetting the pivot point of the scanning mirror placed in the reference arm. Fourier transform along the transverse axis and a filtering algorithm allowed reconstruction of CCR AO-OCT images. The suppression ratio of the mirror artifact was approximately 22 dB (at 18,000 A-scans per second acquisition speed) with a paperboard test target and an optimum phase-shift value. Finally, we reconstructed the three-dimensional structure of human ONH with enhanced depth range and sensitivity using CCR AO-OCT.
Collapse
|
48
|
Abstract
Conventional approaches to optical small animal molecular imaging suffer from poor resolution, limited sensitivity, and unreliable quantitation, often reducing their utility in practice. We previously demonstrated that the in vivo dynamics of an injected contrast agent could be exploited to provide high-contrast anatomical registration, owing to the temporal differences in each organ's response to the circulating fluorophore. This study extends this approach to explore whether dynamic contrast-enhanced optical imaging (DyCE) can allow noninvasive, in vivo assessment of organ function by quantifying the differing cellular uptake or wash-out dynamics of an agent in healthy and damaged organs. Specifically, we used DyCE to visualize and measure the organ-specific uptake dynamics of indocyanine green before and after induction of transient liver damage. DyCE imaging was performed longitudinally over nine days, and blood samples collected at each imaging session were analyzed for alanine aminotransferase (ALT), a liver enzyme assessed clinically as a measure of liver damage. We show that changes in DyCE-derived dynamics of liver and kidney dye uptake caused by liver damage correlate linearly with ALT concentrations, with an r2 value of 0.91. Our results demonstrate that DyCE can provide quantitative, in vivo, longitudinal measures of organ function with inexpensive and simple data acquisition.
Collapse
|
49
|
Follow up of intraocular lens subluxation with a combined topographer/aberrometer. JOURNAL OF OPTOMETRY 2012; 5:147-149. [PMCID: PMC3861158 DOI: 10.1016/j.optom.2012.06.007] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2012] [Accepted: 06/22/2012] [Indexed: 06/10/2023]
Abstract
Purpose To report a 36-year-old patient with intraocular lens (IOL) subluxation that was followed for IOL stability with evaluation of images captured with the iTrace combined aberrometer/topographer. Methods The patient had undergone phacoemulsification with IOL implantation for congenital cataract 15 years before. He presented with bilateral IOL subluxation, more severe in his right eye. Right eye was operated for IOL exchange and left eye was followed with the iTrace images. The images were captured with an infrared camera, and the pupil, the pupil center and the corneal vertex could be detected. The subluxated IOLs edge was visible through infrared light retroillumination. IOL position was evaluated with respect to the pupil, the pupil center and the corneal vertex. Results The patient's left eye was followed for 7 months, and IOL position was noted to be stable. Thus no intervention was planned. Conclusion Evaluation of iTrace images is a reliable method to follow eyes with IOL subluxation.
Collapse
|
50
|
Frequency-domain analysis of photoacoustic imaging data from prostate adenocarcinoma tumors in a murine model. ULTRASOUND IN MEDICINE & BIOLOGY 2011; 37:834-9. [PMID: 21376447 PMCID: PMC3060609 DOI: 10.1016/j.ultrasmedbio.2011.01.012] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/27/2010] [Revised: 01/17/2011] [Accepted: 01/20/2011] [Indexed: 05/05/2023]
Abstract
Photoacoustic imaging is an emerging technique for anatomical and functional sub-surface imaging but previous studies have predominantly focused on time-domain analysis. In this study, frequency-domain analysis of the radio-frequency signals from photoacoustic imaging was performed to generate quantitative parameters for tissue characterization. To account for the response of the imaging system, the photoacoustic spectra were calibrated by dividing the photoacoustic spectra (radio-frequency ultrasound spectra resulting from laser excitation) from tissue by the photoacoustic spectrum of a point absorber excited under the same conditions. The resulting quasi-linear photoacoustic spectra were fit by linear regression and midband fit, slope and intercept were computed from the best-fit line. These photoacoustic spectral parameters were compared between the region-of-interests (ROIs) representing prostate adenocarcinoma tumors and adjacent normal flank tissue in a murine model. The mean midband fit and intercept in the ROIs showed significant differences between cancerous and noncancerous regions. These initial results suggest that such frequency-domain analysis can provide a quantitative method for tumor tissue characterization using photoacoustic imaging in vivo.
Collapse
|