51
|
Azimi P, Stephens B. A framework for estimating the US mortality burden of fine particulate matter exposure attributable to indoor and outdoor microenvironments. JOURNAL OF EXPOSURE SCIENCE & ENVIRONMENTAL EPIDEMIOLOGY 2020; 30:271-284. [PMID: 30518794 PMCID: PMC7039807 DOI: 10.1038/s41370-018-0103-4] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/23/2018] [Revised: 09/25/2018] [Accepted: 11/12/2018] [Indexed: 05/21/2023]
Abstract
Exposure to fine particulate matter (PM2.5) is associated with increased mortality. Although epidemiology studies typically use outdoor PM2.5 concentrations as surrogates for exposure, the majority of PM2.5 exposure in the US occurs in microenvironments other than outdoors. We develop a framework for estimating the total US mortality burden attributable to exposure to PM2.5 of both indoor and outdoor origin in the primary non-smoking microenvironments in which people spend most of their time. The framework utilizes an exposure-response function combined with adjusted mortality effect estimates that account for underlying exposures to PM2.5 of outdoor origin that likely occurred in the original epidemiology populations from which effect estimates are derived. We demonstrate the framework using several different scenarios to estimate the potential magnitude and bounds of the US mortality burden attributable to total PM2.5 exposure across all non-smoking environments under a variety of assumptions. Our best estimates of the US mortality burden associated with total PM2.5 exposure in the year 2012 range from ~230,000 to ~300,000 deaths. Indoor exposure to PM2.5 of outdoor origin is typically the largest total exposure, accounting for ~40-60% of total mortality, followed by residential exposure to indoor PM2.5 sources, which also drives the majority of variability in each scenario.
Collapse
Affiliation(s)
- Parham Azimi
- Department of Civil, Architectural, and Environmental Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Brent Stephens
- Department of Civil, Architectural, and Environmental Engineering, Illinois Institute of Technology, Chicago, IL, USA.
| |
Collapse
|
52
|
Vicente ED, Vicente AM, Evtyugina M, Oduber FI, Amato F, Querol X, Alves C. Impact of wood combustion on indoor air quality. THE SCIENCE OF THE TOTAL ENVIRONMENT 2020; 705:135769. [PMID: 31818582 DOI: 10.1016/j.scitotenv.2019.135769] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/19/2019] [Revised: 11/04/2019] [Accepted: 11/24/2019] [Indexed: 06/10/2023]
Abstract
The incomplete wood combustion in appliances operated in batch mode is a recognised source of both in- and outdoor airborne pollutants, especially particulate matter (PM). Data on pollutant levels and PM characteristics in households with wood burning devices in developed countries are scarce with most studies describing stove change out programmes or other intervention measures. The aim of the present study was to simultaneously evaluate indoor and outdoor concentrations of CO, CO2 and PM10 during the operation of wood burning appliances (open fireplace and woodstove) in unoccupied rural households. PM10 samples were analysed for water soluble inorganic ions, major and trace elements, organic carbon (OC), elemental carbon (EC), and detailed organic speciation. The CO 8-hour average concentrations did not exceed the protection limit despite the sharp increases observed in relation to background levels. During the open fireplace operation, PM10 levels rose up 12 times compared to background concentrations, while the airtight stove resulted in a 2-fold increase. The inhalation cancer risk of particulate bound PAHs in the room equipped with woodstove was estimated to be negligible while the long-term exposure to PAH levels measured in the fireplace room may contribute to the development of cancer. The excess lifetime cancer risk resulting from the particle-bound Cr(VI) exposure during the fireplace and woodstove operation was higher than 1.0 × 10-6 and 1.0 × 10-5, respectively. Levoglucosan was one of the most abundant individual species both indoors and outdoors. This study underlines air pollution hazards and risks arising from the operation of traditional wood burning appliances.
Collapse
Affiliation(s)
- E D Vicente
- Centre for Environmental and Marine Studies, Department of Environment and Planning, University of Aveiro, 3810-193 Aveiro, Portugal.
| | - A M Vicente
- Centre for Environmental and Marine Studies, Department of Environment and Planning, University of Aveiro, 3810-193 Aveiro, Portugal
| | - M Evtyugina
- Centre for Environmental and Marine Studies, Department of Environment and Planning, University of Aveiro, 3810-193 Aveiro, Portugal
| | - F I Oduber
- Department of Physics, IMARENAB University of León, 24071 León, Spain
| | - F Amato
- Institute of Environmental Assessment and Water Research, Spanish Research Council (IDÆA-CSIC), 08034 Barcelona, Spain
| | - X Querol
- Institute of Environmental Assessment and Water Research, Spanish Research Council (IDÆA-CSIC), 08034 Barcelona, Spain
| | - C Alves
- Centre for Environmental and Marine Studies, Department of Environment and Planning, University of Aveiro, 3810-193 Aveiro, Portugal
| |
Collapse
|
53
|
Abbatt JPD, Wang C. The atmospheric chemistry of indoor environments. ENVIRONMENTAL SCIENCE. PROCESSES & IMPACTS 2020; 22:25-48. [PMID: 31712796 DOI: 10.1039/c9em00386j] [Citation(s) in RCA: 75] [Impact Index Per Article: 18.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Through air inhalation, dust ingestion and dermal exposure, the indoor environment plays an important role in controlling human chemical exposure. Indoor emissions and chemistry can also have direct impacts on the quality of outdoor air. And so, it is important to have a strong fundamental knowledge of the chemical processes that occur in indoor environments. This review article summarizes our understanding of the indoor chemistry field. Using a molecular perspective, it addresses primarily the new advances that have occurred in the past decade or so and upon developments in our understanding of multiphase partitioning and reactions. A primary goal of the article is to contrast indoor chemistry to that which occurs outdoors, which we know to be a strongly gas-phase, oxidant-driven system in which substantial oxidative aging of gases and aerosol particles occurs. By contrast, indoor environments are dark, gas-phase oxidant concentrations are relatively low, and due to air exchange, only short times are available for reactive processing of gaseous and particle constituents. However, important gas-surface partitioning and reactive multiphase chemistry occur in the large surface reservoirs that prevail in all indoor environments. These interactions not only play a crucial role in controlling the composition of indoor surfaces but also the surrounding gases and aerosol particles, thus affecting human chemical exposure. There are rich research opportunities available if the advanced measurement and modeling tools of the outdoor atmospheric chemistry community continue to be brought indoors.
Collapse
Affiliation(s)
- Jonathan P D Abbatt
- Department of Chemistry, University of Toronto, 80 St. George St., Toronto, ON M5S 3H6, Canada.
| | - Chen Wang
- Department of Chemistry, University of Toronto, 80 St. George St., Toronto, ON M5S 3H6, Canada.
| |
Collapse
|
54
|
Johnson AL, Gao CX, Dennekamp M, Williamson GJ, Brown D, Carroll MTC, Ikin JF, Del Monaco A, Abramson MJ, Guo Y. Associations between Respiratory Health Outcomes and Coal Mine Fire PM 2.5 Smoke Exposure: A Cross-Sectional Study. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2019; 16:ijerph16214262. [PMID: 31684042 PMCID: PMC6862448 DOI: 10.3390/ijerph16214262] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/23/2019] [Revised: 10/17/2019] [Accepted: 10/31/2019] [Indexed: 12/26/2022]
Abstract
In 2014, wildfires ignited a fire in the Morwell open cut coal mine, Australia, which burned for six weeks. This study examined associations between self-reported respiratory outcomes in adults and mine fire-related PM2.5 smoke exposure. Self-reported data were collected as part of the Hazelwood Health Study Adult Survey. Eligible participants were adult residents of Morwell. Mine fire-related PM2.5 concentrations were provided by the Commonwealth Scientific and Industrial Research Organisation Oceans & Atmosphere Flagship. Personalised mean 24-h and peak 12-h mine fire-related PM2.5 exposures were estimated for each participant. Data were analysed by multivariate logistic regression. There was some evidence of an association between respiratory outcomes and mine fire PM2.5 exposure. Chronic cough was associated with an odds ratio (OR) of 1.13 (95% confidence interval 1.03 to 1.23) per 10 μg/m3 increment in mean PM2.5 and 1.07 (1.02 to 1.12) per 100 μg/m3 increment in peak PM2.5. Current wheeze was associated with peak PM2.5, OR = 1.06 (1.02 to 1.11) and chronic phlegm with mean PM2.5 OR = 1.10 (1.00 to 1.20). Coal mine PM2.5 smoke exposure was associated with increased odds of experiencing cough, phlegm and wheeze. Males, participants 18–64 years, and those residing in homes constructed from non-brick/concrete materials or homes with tin/metal roofs had higher estimated ORs. These findings contribute to the formation of public health policy responses.
Collapse
Affiliation(s)
- Amanda L Johnson
- Department of Epidemiology and Preventive Medicine, School of Public Health and Preventive Medicine, Monash University, Level 2, 553 St Kilda Road, Melbourne, VIC 3004, Australia.
| | - Caroline X Gao
- Department of Epidemiology and Preventive Medicine, School of Public Health and Preventive Medicine, Monash University, Level 2, 553 St Kilda Road, Melbourne, VIC 3004, Australia.
| | - Martine Dennekamp
- Department of Epidemiology and Preventive Medicine, School of Public Health and Preventive Medicine, Monash University, Level 2, 553 St Kilda Road, Melbourne, VIC 3004, Australia.
| | - Grant J Williamson
- School of Natural Sciences, University of Tasmania, Hobart, Tasmania 7001, Australia.
| | - David Brown
- Department of Epidemiology and Preventive Medicine, School of Public Health and Preventive Medicine, Monash University, Level 2, 553 St Kilda Road, Melbourne, VIC 3004, Australia.
| | - Matthew T C Carroll
- Monash Rural Health - Churchill, Monash University, Northways Rd, Churchill, VIC 3842, Australia.
| | - Jillian F Ikin
- Department of Epidemiology and Preventive Medicine, School of Public Health and Preventive Medicine, Monash University, Level 2, 553 St Kilda Road, Melbourne, VIC 3004, Australia.
| | - Anthony Del Monaco
- Department of Epidemiology and Preventive Medicine, School of Public Health and Preventive Medicine, Monash University, Level 2, 553 St Kilda Road, Melbourne, VIC 3004, Australia.
| | - Michael J Abramson
- Department of Epidemiology and Preventive Medicine, School of Public Health and Preventive Medicine, Monash University, Level 2, 553 St Kilda Road, Melbourne, VIC 3004, Australia.
| | - Yuming Guo
- Department of Epidemiology and Preventive Medicine, School of Public Health and Preventive Medicine, Monash University, Level 2, 553 St Kilda Road, Melbourne, VIC 3004, Australia.
| |
Collapse
|
55
|
Wallace L, Jeong SG, Rim D. Dynamic behavior of indoor ultrafine particles (2.3-64 nm) due to burning candles in a residence. INDOOR AIR 2019; 29:1018-1027. [PMID: 31378981 DOI: 10.1111/ina.12592] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/15/2019] [Revised: 07/01/2019] [Accepted: 07/28/2019] [Indexed: 05/28/2023]
Abstract
A major source of human exposure to ultrafine particles is candle use. Candles produce ultrafine particles in the size range under 10 nm, with perhaps half of the particles less than 5 nm. For these small particles at typically high concentrations, coagulation and deposition are two dominant mechanisms in aerosol size dynamics. We present an updated coagulation model capable of characterizing the relative contributions of coagulation, deposition, and air exchange rates. Size-resolved coagulation and decay rates are estimated for three types of candles. Number, area, and mass distributions are provided for 93 particle sizes from 2.33 to 64 nm. Total particle production was in the range of 1013 min-1 . Peak number, area, and mass concentrations occurred at particle sizes of <3, 20, and 40 nm, respectively. Both the number and area concentrations greatly exceeded background concentrations in the residence studied. Contributions of coagulation, deposition, and air exchange rates to particle losses were 65%, 34%, and 0.3% at high concentrations (106 cm-3 ), while they are 17%, 81%, and 1.7% at lower concentrations (3 × 104 cm-3 ), respectively. The increased particle production for the very smallest particles (2.33-2.50 nm) suggests that even smaller particles may be important to study.
Collapse
Affiliation(s)
| | - Su-Gwang Jeong
- Architectural Engineering Department, Pennsylvania State University, University Park, PA
| | - Donghyun Rim
- Architectural Engineering Department, Pennsylvania State University, University Park, PA
| |
Collapse
|
56
|
Lowther SD, Jones KC, Wang X, Whyatt JD, Wild O, Booker D. Particulate Matter Measurement Indoors: A Review of Metrics, Sensors, Needs, and Applications. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2019; 53:11644-11656. [PMID: 31512864 DOI: 10.1021/acs.est.9b03425] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Many populations spend ∼90% of their time indoors, with household particulate matter being linked to millions of premature deaths worldwide. Particulate matter is currently measured using particle mass, particle number, and particle size distribution metrics, with other metrics, such as particle surface area, likely to be of increasing importance in the future. Particulate mass is measured using gravimetric methods, tapered element oscillating microbalances, and beta attenuation instruments and is best suited to use in compliance monitoring, trend analysis, and high spatial resolution measurements. Particle number concentration is measured by condensation particle counters, optical particle counters, and diffusion chargers. Particle number measurements are best suited to source characterization, trend analysis and ultrafine particle investigations. Particle size distributions are measured by gravimetric impactors, scanning mobility particle sizers, aerodynamic particle sizers, and fast mobility particle sizers. Particle size distribution measurements are most useful in source characterization and particulate matter property investigations, but most measurement options remain expensive and intrusive. However, we are on the cusp of a revolution in indoor air quality monitoring and management. Low-cost sensors have potential to facilitate personalized information about indoor air quality (IAQ), allowing citizens to reduce exposures to PM indoors and to resolve potential dichotomies between promoting healthy IAQ and energy efficient buildings. Indeed, the low cost will put this simple technology in the hands of citizens who wish to monitor their own IAQ in the home or workplace, to inform lifestyle decisions. Low-cost sensor networks also look promising as the solution to measuring spatial distributions of PM indoors, however, there are important sensor/data quality, technological, and ethical barriers to address with this technology. An improved understanding of epidemiology is essential to identify which metrics correlate most with health effects, allowing indoor specific PM standards to be developed and to inform the future of experimental applications.
Collapse
Affiliation(s)
- Scott D Lowther
- Lancaster Environment Centre , Lancaster University , Lancaster LA1 4YQ , United Kingdom
- State Key Laboratory of Organic Geochemistry, Guangzhou Institute of Geochemistry , Chinese Academy of Sciences , 511 Kehua Rd , Tianhe, Guangzhou 510640 , China
| | - Kevin C Jones
- Lancaster Environment Centre , Lancaster University , Lancaster LA1 4YQ , United Kingdom
| | - Xinming Wang
- State Key Laboratory of Organic Geochemistry, Guangzhou Institute of Geochemistry , Chinese Academy of Sciences , 511 Kehua Rd , Tianhe, Guangzhou 510640 , China
| | - J Duncan Whyatt
- Lancaster Environment Centre , Lancaster University , Lancaster LA1 4YQ , United Kingdom
| | - Oliver Wild
- Lancaster Environment Centre , Lancaster University , Lancaster LA1 4YQ , United Kingdom
| | - Douglas Booker
- NAQTS, Lancaster Environment Centre , Lancaster University , Lancaster , LA14YQ , United Kingdom
| |
Collapse
|
57
|
Shrestha PM, Humphrey JL, Carlton EJ, Adgate JL, Barton KE, Root ED, Miller SL. Impact of Outdoor Air Pollution on Indoor Air Quality in Low-Income Homes during Wildfire Seasons. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2019; 16:E3535. [PMID: 31546585 PMCID: PMC6801919 DOI: 10.3390/ijerph16193535] [Citation(s) in RCA: 55] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/04/2019] [Revised: 09/17/2019] [Accepted: 09/18/2019] [Indexed: 01/02/2023]
Abstract
Indoor and outdoor number concentrations of fine particulate matter (PM2.5), black carbon (BC), carbon monoxide (CO), and nitrogen dioxide (NO2) were monitored continuously for two to seven days in 28 low-income homes in Denver, Colorado, during the 2016 and 2017 wildfire seasons. In the absence of indoor sources, all outdoor pollutant concentrations were higher than indoors except for CO. Results showed that long-range wildfire plumes elevated median indoor PM2.5 concentrations by up to 4.6 times higher than outdoors. BC, CO, and NO2 mass concentrations were higher indoors in homes closer to roadways compared to those further away. Four of the homes with mechanical ventilation systems had 18% higher indoor/outdoor (I/O) ratios of PM2.5 and 4% higher I/O ratios of BC compared to other homes. Homes with exhaust stove hoods had PM2.5 I/O ratios 49% less than the homes with recirculating hoods and 55% less than the homes with no stove hoods installed. Homes with windows open for more than 12 hours a day during sampling had indoor BC 2.4 times higher than homes with windows closed. This study provides evidence that long-range wildfire plumes, road proximity, and occupant behavior have a combined effect on indoor air quality in low-income homes.
Collapse
Affiliation(s)
- Prateek M Shrestha
- Department of Mechanical Engineering, University of Colorado Boulder, Boulder, CO 80309, USA.
| | - Jamie L Humphrey
- Department of Mechanical Engineering, University of Colorado Boulder, Boulder, CO 80309, USA.
| | - Elizabeth J Carlton
- Department of Environmental and Occupational Health, University of Colorado, Colorado School of Public Health, Aurora, CO 80045, USA.
| | - John L Adgate
- Department of Environmental and Occupational Health, University of Colorado, Colorado School of Public Health, Aurora, CO 80045, USA.
| | - Kelsey E Barton
- Department of Environmental and Occupational Health, University of Colorado, Colorado School of Public Health, Aurora, CO 80045, USA.
| | - Elisabeth D Root
- Department of Geography and Division of Epidemiology, The Ohio State University, 1036 Derby Hall, 154 North Oval Mall, Columbus, OH 43210, USA.
| | - Shelly L Miller
- Department of Mechanical Engineering, University of Colorado Boulder, Boulder, CO 80309, USA.
| |
Collapse
|
58
|
Rosofsky A, Levy JI, Breen MS, Zanobetti A, Fabian MP. The impact of air exchange rate on ambient air pollution exposure and inequalities across all residential parcels in Massachusetts. JOURNAL OF EXPOSURE SCIENCE & ENVIRONMENTAL EPIDEMIOLOGY 2019; 29:520-530. [PMID: 30242266 PMCID: PMC6428635 DOI: 10.1038/s41370-018-0068-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2017] [Revised: 07/20/2018] [Accepted: 08/06/2018] [Indexed: 05/17/2023]
Abstract
Individual housing characteristics can modify outdoor ambient air pollution infiltration through air exchange rate (AER). Time and labor-intensive methods needed to measure AER has hindered characterization of AER distributions across large geographic areas. Using publicly-available data and regression models associating AER with housing characteristics, we estimated AER for all Massachusetts residential parcels. We conducted an exposure disparities analysis, considering ambient PM2.5 concentrations and residential AERs. Median AERs (h-1) with closed windows for winter and summer were 0.74 (IQR: 0.47-1.09) and 0.36 (IQR: 0.23-0.57), respectively, with lower AERs for single family homes. Across residential parcels, variability of indoor PM2.5 concentrations of ambient origin was twice that of ambient PM2.5 concentrations. Housing parcels above the 90th percentile of both AER and ambient PM2.5 (i.e., the leakiest homes in areas of highest ambient PM2.5)-vs. below the 10 percentile-were located in neighborhoods with higher proportions of Hispanics (20.0% vs. 2.0%), households with an annual income of less than $20,000 (26.0% vs. 7.5%), and individuals with less than a high school degree (23.2% vs. 5.8%). Our approach can be applied in epidemiological studies to estimate exposure modifiers or to characterize exposure disparities that are not solely based on ambient concentrations.
Collapse
Affiliation(s)
- Anna Rosofsky
- Department of Environmental Health, Boston University School of Public Health, Boston, MA, USA.
| | - Jonathan I Levy
- Department of Environmental Health, Boston University School of Public Health, Boston, MA, USA
| | - Michael S Breen
- National Exposure Research Laboratory, U.S. Environmental Protection Agency, Research Triangle Park, NC, USA
| | - Antonella Zanobetti
- Department of Environmental Health, Harvard T.H. Chan School of Public Health, Boston, MA, USA
| | - M Patricia Fabian
- Department of Environmental Health, Boston University School of Public Health, Boston, MA, USA
| |
Collapse
|
59
|
McGrath JA, O'Toole C, Bennett G, Joyce M, Byrne MA, MacLoughlin R. Investigation of Fugitive Aerosols Released into the Environment during High-Flow Therapy. Pharmaceutics 2019; 11:E254. [PMID: 31159408 PMCID: PMC6630289 DOI: 10.3390/pharmaceutics11060254] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2019] [Revised: 05/24/2019] [Accepted: 05/28/2019] [Indexed: 11/16/2022] Open
Abstract
BACKGROUND Nebulised medical aerosols are designed to deliver drugs to the lungs to aid in the treatment of respiratory diseases. However, an unintended consequence is the potential for fugitive emissions during patient treatment, which may pose a risk factor in both clinical and homecare settings. METHODS The current study examined the potential for fugitive emissions, using albuterol sulphate as a tracer aerosol during high-flow therapy. A nasal cannula was connected to a head model or alternatively, a interface was connected to a tracheostomy tube in combination with a simulated adult and paediatric breathing profile. Two aerodynamic particle sizers (APS) recorded time-series aerosol concentrations and size distributions at two different distances relative to the simulated patient. RESULTS The results showed that the quantity and characteristics of the fugitive emissions were influenced by the interface type, patient type and supplemental gas-flow rate. There was a trend in the adult scenarios; as the flow rate increased, the fugitive emissions and the mass median aerodynamic diameter (MMAD) of the aerosol both decreased. The fugitive emissions were comparable when using the adult breathing profiles for the nasal cannula and tracheostomy interfaces; however, there was a noticeable distinction between the two interfaces when compared for the paediatric breathing profiles. The highest recorded aerosol concentration was 0.370 ± 0.046 mg m-3 from the tracheostomy interface during simulated paediatric breathing with a gas-flow rate of 20 L/min. The averaged MMAD across all combinations ranged from 1.248 to 1.793 µm by the APS at a distance of 0.8 m away from the patient interface. CONCLUSIONS Overall, the results highlight the potential for secondary inhalation of fugitive emissions released during simulated aerosol treatment with concurrent high-flow therapy. The findings will help in developing policy and best practice for risk mitigation from fugitive emissions.
Collapse
Affiliation(s)
- James A McGrath
- School of Physics & Centre for Climate and Air Pollution Studies, Ryan Institute, National University of Ireland Galway, H91 CF50 Galway, Ireland.
| | - Ciarraí O'Toole
- School of Physics & Centre for Climate and Air Pollution Studies, Ryan Institute, National University of Ireland Galway, H91 CF50 Galway, Ireland.
| | - Gavin Bennett
- Aerogen, IDA Business Park, Dangan, H91 HE94 Galway, Ireland.
| | - Mary Joyce
- Aerogen, IDA Business Park, Dangan, H91 HE94 Galway, Ireland.
| | - Miriam A Byrne
- School of Physics & Centre for Climate and Air Pollution Studies, Ryan Institute, National University of Ireland Galway, H91 CF50 Galway, Ireland.
| | | |
Collapse
|
60
|
Taylor J, Shrubsole C, Symonds P, Mackenzie I, Davies M. Application of an indoor air pollution metamodel to a spatially-distributed housing stock. THE SCIENCE OF THE TOTAL ENVIRONMENT 2019; 667:390-399. [PMID: 30831373 PMCID: PMC6467545 DOI: 10.1016/j.scitotenv.2019.02.341] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2018] [Revised: 02/19/2019] [Accepted: 02/21/2019] [Indexed: 05/19/2023]
Abstract
Estimates of population air pollution exposure typically rely on the outdoor component only, and rarely account for populations spending the majority of their time indoors. Housing is an important modifier of air pollution exposure due to outdoor pollution infiltrating indoors, and the removal of indoor-sourced pollution through active or passive ventilation. Here, we describe the application of an indoor air pollution modelling tool to a spatially distributed housing stock model for England and Wales, developed from Energy Performance Certificate (EPC) data and containing information for approximately 11.5 million dwellings. First, we estimate indoor/outdoor (I/O) ratios and total indoor concentrations of outdoor air pollution for PM2.5 and NO2 for all EPC dwellings in London. The potential to estimate concentration from both indoor and outdoor sources is then demonstrated by modelling indoor background CO levels for England and Wales pre- and post-energy efficient adaptation, including heating, cooking, and smoking as internal sources. In London, we predict a median I/O ratio of 0.60 (99% CIs; 0.53-0.73) for outdoor PM2.5 and 0.41 (99%CIs; 0.34-0.59) for outdoor NO2; Pearson correlation analysis indicates a greater spatial modification of PM2.5 exposure by housing (ρ = 0.81) than NO2 (ρ = 0.88). For the demonstrative CO model, concentrations ranged from 0.4-9.9 ppm (99%CIs)(median = 3.0 ppm) in kitchens and 0.3-25.6 ppm (median = 6.4 ppm) in living rooms. Clusters of elevated indoor concentration are found in urban areas due to higher outdoor concentrations and smaller dwellings with reduced ventilation potential, with an estimated 17.6% increase in the number of living rooms and 63% increase in the number of kitchens exceeding recommended exposure levels following retrofit without additional ventilation. The model has the potential to rapidly calculate indoor pollution exposure across large housing stocks and estimate changes to exposure under different pollution or housing policy scenarios.
Collapse
Affiliation(s)
- Jonathon Taylor
- UCL Institute for Environmental Design and Engineering, Central House, 14 Upper Woburn Plc, London WC1H 0NN, UK.
| | - Clive Shrubsole
- UCL Institute for Environmental Design and Engineering, Central House, 14 Upper Woburn Plc, London WC1H 0NN, UK
| | - Phil Symonds
- UCL Institute for Environmental Design and Engineering, Central House, 14 Upper Woburn Plc, London WC1H 0NN, UK
| | - Ian Mackenzie
- University of Edinburgh School of GeoSciences, Crew Building, The King's Buildings, Alexander Crum Brown Road, Edinburgh EH9 3FF, UK
| | - Mike Davies
- UCL Institute for Environmental Design and Engineering, Central House, 14 Upper Woburn Plc, London WC1H 0NN, UK
| |
Collapse
|
61
|
Huang G, Zhou W, Qian Y, Fisher B. Breathing the same air? Socioeconomic disparities in PM 2.5 exposure and the potential benefits from air filtration. THE SCIENCE OF THE TOTAL ENVIRONMENT 2019; 657:619-626. [PMID: 30677928 DOI: 10.1016/j.scitotenv.2018.11.428] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/11/2018] [Revised: 11/13/2018] [Accepted: 11/28/2018] [Indexed: 05/17/2023]
Abstract
Air pollution caused by particulate matter <2.5 μm in diameter (PM2.5) imposes a severe health burden to people worldwide. Across the globe, and even within cities, the health burden of air pollution is not equally shared by citizens. Despite being the region suffering from the most severe air pollution, studies examining the inequity of the burdens of air pollution in Asia are limited. We aim to fill in this gap by analyzing the relationship between PM2.5 pollution and residents' socioeconomic characteristics in Beijing, the icon city for PM2.5 pollution. Our results show that household income and education were negatively correlated with ambient air quality (r = -0.62; p < 0.05 and r = -0.73; p < 0.01 respectively) in 2014. We found in Beijing air quality is worse where residents have less income and lower education rates and are less capable to protect themselves from the potential health risk. To counter the effects of air pollution in Beijing, air filtration has been shown to be an effective means to reduce, at least, indoor PM2.5 levels. We illustrate through a simple scenario analysis that air filtration can reduce exposure (26-79%) to a similar extent as the structural mitigation programs (e.g. closing coal factories) achieved in recent years (53%). We argue government intervention is needed to convey the benefit of air filtration to the socioeconomically disadvantaged groups.
Collapse
Affiliation(s)
- Ganlin Huang
- Center for Human-Environment System Sustainability (CHESS), State Key Laboratory of Earth Surface Processes and Resource Ecology (ESPRE), Beijing Normal University, No 19 Xinjiekouwai Road, Beijing 100875, China; School of Natural Resources, Faculty of Geographical Science, Beijing Normal University, Beijing, 100875, China.
| | - Weiqi Zhou
- State Key Laboratory of Urban and Regional Ecology, Research Center for Eco-environmental Science, Chinese Academy of Sciences, No 18 Shuangqing Road, Beijing 100085, China
| | - Yuguo Qian
- State Key Laboratory of Urban and Regional Ecology, Research Center for Eco-environmental Science, Chinese Academy of Sciences, No 18 Shuangqing Road, Beijing 100085, China
| | - Brendan Fisher
- Gund Institute/Rubenstein School of Environment and Natural Resources, University of Vermont, Aiken Center, 81 Carrigan Drive, Burlington, VT 05405, USA
| |
Collapse
|
62
|
Designing Safe General LED Lighting that Provides the UVB Benefits of Sunlight. APPLIED SCIENCES-BASEL 2019. [DOI: 10.3390/app9050826] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
The ultraviolet (UV) rays emitted from sunlight greatly influence human health. Excessive exposure to UV rays can be harmful to eyes and skin; however, limited UVB exposure is essential for the synthesis of vitamin D. Nowadays, owing to insufficient exposure to natural light, there is increasing concerns about low vitamin D amongst individuals. To address this issue, many lighting devices that provide UVB doses have been released; however, such devices are only used for treatments or for special purposes. This study proposes a general indoor lighting system with a UVB LED light source to provide safe UVB doses to users who spend large amounts of time indoors. The optical characteristics of two UVB LEDs with output of 20 and 100 mW were analyzed based on their distances and applied currents. The light source combination of UVB LEDS that meets the UV hazard standard of IEC-62471 was derived; this is a photobiological safety evaluation standard of LED lighting devices. We then produced a lighting module in which the UVB LED light source was applied to general LED lighting and measured and analyzed the spectral irradiance of the proposed lighting according to the measurement standard for the general lighting of IEC 62471. The actinic UV hazard (AUV) and near-UV hazard (NUV) were calculated to be 0.001 and 10 W/m2, respectively. Thus, the provision of UVB dose did not pose any risks. In addition, the total EUV (Erythemal weighted UV) dose when the proposed lighting was implemented for 16 h was 187.66 J/m2, confirming that this dose did not cause erythema for the general skin types (Skin Types 1–6). Further, the design plan of general indoor lighting with a UVB LED light source is presented.
Collapse
|
63
|
McGrath JA, O'Sullivan A, Bennett G, O'Toole C, Joyce M, Byrne MA, MacLoughlin R. Investigation of the Quantity of Exhaled Aerosols Released into the Environment during Nebulisation. Pharmaceutics 2019; 11:E75. [PMID: 30759879 PMCID: PMC6409895 DOI: 10.3390/pharmaceutics11020075] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2019] [Revised: 02/05/2019] [Accepted: 02/08/2019] [Indexed: 12/29/2022] Open
Abstract
BACKGROUND Secondary inhalation of medical aerosols is a significant occupational hazard in both clinical and homecare settings. Exposure to fugitive emissions generated during aerosol therapy increases the risk of the unnecessary inhalation of medication, as well as toxic side effects. METHODS This study examines fugitively-emitted aerosol emissions when nebulising albuterol sulphate, as a tracer aerosol, using two commercially available nebulisers in combination with an open or valved facemask or using a mouthpiece with and without a filter on the exhalation port. Each combination was connected to a breathing simulator during simulated adult breathing. The inhaled dose and residual mass were quantified using UV spectrophotometry. Time-varying fugitively-emitted aerosol concentrations and size distributions during nebulisation were recorded using aerodynamic particle sizers at two distances relative to the simulated patient. Different aerosol concentrations and size distributions were observed depending on the interface. RESULTS Within each nebuliser, the facemask combination had the highest time-averaged fugitively-emitted aerosol concentration, and values up to 0.072 ± 0.001 mg m-3 were recorded. The placement of a filter on the exhalation port of the mouthpiece yielded the lowest recorded concentrations. The mass median aerodynamic diameter of the fugitively-emitted aerosol was recorded as 0.890 ± 0.044 µm, lower the initially generated medical aerosol in the range of 2⁻5 µm. CONCLUSIONS The results highlight the potential secondary inhalation of exhaled aerosols from commercially available nebuliser facemask/mouthpiece combinations. The results will aid in developing approaches to inform policy and best practices for risk mitigation from fugitive emissions.
Collapse
Affiliation(s)
- James A McGrath
- School of Physics & Centre for Climate and Air Pollution Studies, Ryan Institute, National University of Ireland Galway, Galway, H91 CF50, Ireland.
| | | | - Gavin Bennett
- Aerogen, IDA Business Park, Dangan, Galway, H91 HE94, Ireland.
| | - Ciarraí O'Toole
- School of Physics & Centre for Climate and Air Pollution Studies, Ryan Institute, National University of Ireland Galway, Galway, H91 CF50, Ireland.
| | - Mary Joyce
- Aerogen, IDA Business Park, Dangan, Galway, H91 HE94, Ireland.
| | - Miriam A Byrne
- School of Physics & Centre for Climate and Air Pollution Studies, Ryan Institute, National University of Ireland Galway, Galway, H91 CF50, Ireland.
| | | |
Collapse
|
64
|
Shao Z, Yin X, Bi J, Ma Z, Wang J. Spatiotemporal Variations of Indoor PM 2.5 Concentrations in Nanjing, China. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2019; 16:E144. [PMID: 30621102 PMCID: PMC6339030 DOI: 10.3390/ijerph16010144] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/10/2018] [Revised: 12/19/2018] [Accepted: 12/27/2018] [Indexed: 11/20/2022]
Abstract
Indoor fine particulate matter (PM2.5) is important since people spend most of their time indoors. However, knowledge of the spatiotemporal variations of indoor PM2.5 concentrations within a city is limited. In this study, the spatiotemporal distributions of indoor PM2.5 levels in Nanjing, China were modeled by the multizone airflow and contaminant transport program (CONTAM), based on the geographically distributed residences, human activities, and outdoor PM2.5 concentrations. The accuracy of the CONTAM model was verified, with a good agreement between the model simulations and measurements (r = 0.940, N = 110). Two different scenarios were considered to examine the building performance and influence of occupant behaviors. Higher PM2.5 concentrations were observed under the scenario when indoor activities were considered. Seasonal variability was observed in indoor PM2.5 levels, with the highest concentrations occurring in the winter and the lowest occurring in the summer. Building characteristics have a significant effect on the spatial distribution of indoor PM2.5 concentrations, with multistory residences being more vulnerable to outdoor PM2.5 infiltration than high-rise residences. The overall population exposure to PM2.5 in Nanjing was estimated. It would be overestimated by 16.67% if indoor exposure was not taken into account, which would lead to a bias in the health impacts assessment.
Collapse
Affiliation(s)
- Zhijuan Shao
- State Key Laboratory of Pollution Control & Resource Reuse, School of the Environment, Nanjing University, Nanjing 210023, China.
| | - Xiangjun Yin
- Nanjing Urban Planning & Research Center, Nanjing 210029, China.
| | - Jun Bi
- State Key Laboratory of Pollution Control & Resource Reuse, School of the Environment, Nanjing University, Nanjing 210023, China.
- Jiangsu Collaborative Innovation Center of Atmospheric Environment and Equipment Technology, Nanjing University of Information Science & Technology, Nanjing 210044, China.
| | - Zongwei Ma
- State Key Laboratory of Pollution Control & Resource Reuse, School of the Environment, Nanjing University, Nanjing 210023, China.
- Jiangsu Collaborative Innovation Center of Atmospheric Environment and Equipment Technology, Nanjing University of Information Science & Technology, Nanjing 210044, China.
| | - Jinnan Wang
- State Key Laboratory of Pollution Control & Resource Reuse, School of the Environment, Nanjing University, Nanjing 210023, China.
- State Environmental Protection Key Laboratory of Environmental Planning and Policy Simulation, Chinese Academy for Environmental Planning, Beijing 100012, China.
| |
Collapse
|
65
|
Cong XC, Zhao JJ, Jing Z, Wang QG, Ni PF. Indoor particle dynamics in a school office: determination of particle concentrations, deposition rates and penetration factors under naturally ventilated conditions. ENVIRONMENTAL GEOCHEMISTRY AND HEALTH 2018; 40:2511-2524. [PMID: 29744699 DOI: 10.1007/s10653-018-0116-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2017] [Accepted: 05/04/2018] [Indexed: 05/24/2023]
Abstract
Recently, the problem of indoor particulate matter pollution has received much attention. An increasing number of epidemiological studies show that the concentration of atmospheric particulate matter has a significant effect on human health, even at very low concentrations. Most of these investigations have relied upon outdoor particle concentrations as surrogates of human exposures. However, considering that the concentration distribution of the indoor particulate matter is largely dependent on the extent to which these particles penetrate the building and on the degree of suspension in the indoor air, human exposures to particles of outdoor origin may not be equal to outdoor particle concentration levels. Therefore, it is critical to understand the relationship between the particle concentrations found outdoors and those found in indoor micro-environments. In this study, experiments were conducted using a naturally ventilated office located in Qingdao, China. The indoor and outdoor particle concentrations were measured at the same time using an optical counter with four size ranges. The particle size distribution ranged from 0.3 to 2.5 μm, and the experimental period was from April to September, 2016. Based on the experimental data, the dynamic and mass balance model based on time was used to estimate the penetration rate and deposition rate at air exchange rates of 0.03-0.25 h-1. The values of the penetration rate and deposition velocity of indoor particles were determined to range from 0.45 to 0.82 h-1 and 1.71 to 2.82 m/h, respectively. In addition, the particulate pollution exposure in the indoor environment was analyzed to estimate the exposure hazard from indoor particulate matter pollution, which is important for human exposure to particles and associated health effects. The conclusions from this study can serve to provide a better understanding the dynamics and behaviors of airborne particle entering into buildings. And they will also highlight effective methods to reduce exposure to particles in office buildings.
Collapse
Affiliation(s)
- X C Cong
- Shandong Provincial Key Laboratory of Civil Engineering Disaster Prevention and Mitigation, Shandong University of Science and Technology, Qingdao, 266590, China.
| | - J J Zhao
- Shandong Provincial Key Laboratory of Civil Engineering Disaster Prevention and Mitigation, Shandong University of Science and Technology, Qingdao, 266590, China
| | - Z Jing
- Shandong Provincial Key Laboratory of Civil Engineering Disaster Prevention and Mitigation, Shandong University of Science and Technology, Qingdao, 266590, China
| | - Q G Wang
- Shandong Provincial Key Laboratory of Civil Engineering Disaster Prevention and Mitigation, Shandong University of Science and Technology, Qingdao, 266590, China
| | - P F Ni
- Shandong Provincial Key Laboratory of Civil Engineering Disaster Prevention and Mitigation, Shandong University of Science and Technology, Qingdao, 266590, China
| |
Collapse
|
66
|
Xue J, Li Y, Peppers J, Wan C, Kado NY, Green PG, Young TM, Kleeman MJ. Ultrafine Particle Emissions from Natural Gas, Biogas, and Biomethane Combustion. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2018; 52:13619-13628. [PMID: 30296061 DOI: 10.1021/acs.est.8b04170] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Biogas and biomethane (=purified biogas) are major renewable fuels that play a pivotal role in the evolving global energy economy. Here, we measure ultrafine particle (UFP; Dp (particle diameter) < 100 nm) emissions from the combustion of biomethane and biogas produced from five different representative sources: two food waste digesters, two dairy waste digesters, and one landfill. Combustion exhaust for each of these sources is measured from one or more representative sectors including electricity generation, motor vehicles, and household use. Results show that UFP emissions are similar when using biomethane and natural gas with similar sulfur and siloxane content. Approximately 70% of UFPs emitted from water heaters and cooking stoves were semivolatile, but 30% of the UFPs were nonvolatile and did not evaporate even under extremely high dilution conditions. Photochemical aging of biomethane combustion exhaust and natural gas combustion exhaust produced similar amounts of secondary organic aerosol (SOA) formation. The results of the current study suggest that widespread adoption of biogas and biomethane as a substitute for natural gas will not significantly increase ambient concentrations of primary and secondary UFPs if advanced combustion technology is used and the sulfur and siloxane content is similar for biogas/biomethane and natural gas.
Collapse
Affiliation(s)
- Jian Xue
- Department of Civil and Environmental Engineering , University of California-Davis , Davis , California 95616 , United States
| | - Yin Li
- Department of Civil and Environmental Engineering , University of California-Davis , Davis , California 95616 , United States
| | - Joshua Peppers
- Department of Civil and Environmental Engineering , University of California-Davis , Davis , California 95616 , United States
| | - Chao Wan
- Atmospheric Science Graduate Group , University of California-Davis , Davis , California 95616 , United States
| | - Norman Y Kado
- Department of Environmental Toxicology , University of California-Davis , Davis , California 95616 , United States
| | - Peter G Green
- Department of Civil and Environmental Engineering , University of California-Davis , Davis , California 95616 , United States
| | - Thomas M Young
- Department of Civil and Environmental Engineering , University of California-Davis , Davis , California 95616 , United States
| | - Michael J Kleeman
- Department of Civil and Environmental Engineering , University of California-Davis , Davis , California 95616 , United States
| |
Collapse
|
67
|
Xie Y, Zhao B. Chemical composition of outdoor and indoor PM 2.5 collected during haze events: Transformations and modified source contributions resulting from outdoor-to-indoor transport. INDOOR AIR 2018; 28:828-839. [PMID: 30156041 DOI: 10.1111/ina.12503] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/15/2018] [Revised: 08/18/2018] [Accepted: 08/21/2018] [Indexed: 06/08/2023]
Abstract
Changes in the chemical constitution and sources of ambient PM2.5 following the infiltration of air into indoor environments were investigated. We collected PM2.5 samples from air inside and outside 31 rooms in Beijing residences during hazy episodes. We calculated the indoor-to-outdoor ratios and the correction (ki ) of each infiltration factor for each chemical component of PM2.5 to determine the effects of infiltrative behavior. The outdoor and indoor mass concentrations of PM2.5 during the sampling period were 70-460 and 10-315 μg/m3 , respectively. Differences in the average indoor-to-outdoor ratios of PM2.5 mass and each component (mean value ± standard deviation: PM2.5 mass = 0.53 ± 0.26, organic matter = 0.75 ± 0.34, elemental carbon = 0.62 ± 0.31, trace elements = 0.62 ± 0.26, SO 4 2 - = 0.67 ± 0.32 , NH 4 + = 0.53 ± 0.54 , NO 3 - = 0.45 ± 0.36 , Cl- = 0.37 ± 0.35, and crustal dust = 0.30 ± 0.19) may be attributed to size distribution, chemical properties, temperature, and humidity. The positive matrix factorization model was applied to calculate the source contributions to equivalent population exposure (Indoor concentration·Indoor time fraction + Outdoor concentration·Outdoor time fraction). The contributions of fossil fuel combustion, secondary source, vehicle exhaust, and mixed dust to the equivalent PM2.5 population source exposure were 37%, 24%, 22%, and 17%, respectively.
Collapse
Affiliation(s)
- Yangyang Xie
- Department of Building Science, School of Architecture, Tsinghua University, Beijing, China
| | - Bin Zhao
- Department of Building Science, School of Architecture, Tsinghua University, Beijing, China
- Beijing Key Laboratory of Indoor Air Quality Evaluation and Control, Tsinghua University, Beijing, China
| |
Collapse
|
68
|
Rohra H, Tiwari R, Khare P, Taneja A. Indoor-outdoor association of particulate matter and bounded elemental composition within coarse, quasi-accumulation and quasi-ultrafine ranges in residential areas of northern India. THE SCIENCE OF THE TOTAL ENVIRONMENT 2018; 631-632:1383-1397. [PMID: 29727962 DOI: 10.1016/j.scitotenv.2018.03.095] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/28/2017] [Revised: 03/07/2018] [Accepted: 03/09/2018] [Indexed: 06/08/2023]
Abstract
Attempts have been made to comprehend size distribution pattern of Particulate Matter (PM) and associated elemental concentration within coarse (2.5-10μm), quasi-accumulation (q-Acc) (0.25-2.5μm) and quasi-ultrafine (q-UF) (<0.25μm) ranges at indoors and outdoors of residential homes of Agra. Overall, the average mass concentrations of PM10 and PM2.5 in indoors were found to be 263.24±59.24 and 212.01±38.06μgm-3 while in outdoors the concentrations accounted to 194.28±15.25 and 152.88±16.31μgm-3 respectively; exceeding WHO standards. In view of geographical variation, significantly higher (t=2.461; P=0.044) PM mass was found in outdoor samples of roadside location when compared to homes located far away from busy traffic; whereas indoor concentration exhibited non-significant relationship (t=1.887; P=0.095) between the two categorized homes. Findings of size partitioning trend through deployment of Sioutas Cascade Impactor evidenced presence of high proportion of PM and elemental concentrations within q-Acc and q-UF modes with their distribution pattern and probable emission sources conferred upon. Absence of modal peak in coarse range indicated predominance of anthropogenic emissions with presumed wash-out of coarse particles during frequent precipitation coincidental with sampling event. Seeming modal shifts for some elements (K, Cd, Zn) from q-Acc to q-UF were perceived during infiltration process. Presence of high traffic emission in homes near busy road stemmed the shifting of particles (Cu, K, Co, Zn) towards finer size (preferably q-UF mode) thus exposing residents to adverse health effects through their penetration (Finf=0.14) into indoor environment. Flat slopes (0.11) and poor correlation (8.4%) for metals in coarser range obtained through regression model hypothesized their high deposition velocities and low penetration efficiency. Our findings suggest enhanced resident exposure to fine particles (81%) especially q-UF range (37%) through indoor and outdoor (through infiltration) sources along with complexity of size distribution of airborne particles that prerequisites surplus consideration to achieve a healthier environment within residential area.
Collapse
Affiliation(s)
- Himanshi Rohra
- Department of Chemistry, Dr. Bhimrao Ambedkar University, Agra 282002, India.
| | - Rahul Tiwari
- Department of Chemistry, Dr. Bhimrao Ambedkar University, Agra 282002, India
| | - Puja Khare
- Central Institute of Medicinal and Aromatic Plants (CIMAP), Lucknow 226015, India
| | - Ajay Taneja
- Department of Chemistry, Dr. Bhimrao Ambedkar University, Agra 282002, India.
| |
Collapse
|
69
|
Zauli-Sajani S, Rovelli S, Trentini A, Bacco D, Marchesi S, Scotto F, Zigola C, Lauriola P, Cavallo DM, Poluzzi V, Cattaneo A, Hänninen O. Higher health effects of ambient particles during the warm season: The role of infiltration factors. THE SCIENCE OF THE TOTAL ENVIRONMENT 2018; 627:67-77. [PMID: 29426191 DOI: 10.1016/j.scitotenv.2018.01.217] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/25/2017] [Revised: 01/19/2018] [Accepted: 01/22/2018] [Indexed: 06/08/2023]
Abstract
A large number of studies have shown much higher health effects of particulate matter (PM) during the warm compared to the cold season. In this paper we present the results of an experimental study carried out in an unoccupied test apartment with the aim of understanding the reasons behind the seasonal variations of the health effects due to ambient PM2.5 exposure. Measurements included indoor and outdoor PM2.5 mass and chemical composition as well as particle size distribution of ultrafine particles. Monitoring campaigns were carried out during summer and winter following a ventilation protocol developed to replicate typical occupant behaviour according to a questionnaire-based survey. Our findings showed that seasonal variation of the relationship between ambient and indoor mass concentrations cannot entirely explain the apparent difference in PM toxicity between seasons and size distribution and chemical composition of particles were identified as other possible causes of changes in the apparent PM toxicity. A marked decrease of ultrafine particles (<100 nm) passing from outdoors to indoors was observed during winter; this resulted in higher indoor exposure to nanoparticles (<50 nm) during summer. With regards to the chemical composition, a pooled analysis showed infiltration factors of chemical species similar to that obtained for PM2.5 mass with values increasing from 0.73 during winter to 0.90 during summer and few deviations from the pooled estimates. In particular, significantly lower infiltration factors and sink effect were found for nitrates and ammonium during winter. In addition, a marked increase in the contribution of indoor and outdoor sulfates to the total mass was observed during summer.
Collapse
Affiliation(s)
- Stefano Zauli-Sajani
- Regional Centre for Environment and Health, Arpae Emilia-Romagna, Via Begarelli, 13, 41121 Modena, Italy.
| | - Sabrina Rovelli
- Department of Science and High Technology, Università degli Studi dell'Insubria, Via Valleggio 11, 22100 Como, Italy
| | - Arianna Trentini
- Regional Centre for Urban Areas, Arpae Emilia-Romagna, Largo Caduti del Lavoro, 6, 40122 Bologna, Italy
| | - Dimitri Bacco
- Regional Centre for Urban Areas, Arpae Emilia-Romagna, Largo Caduti del Lavoro, 6, 40122 Bologna, Italy
| | - Stefano Marchesi
- Regional Centre for Environment and Health, Arpae Emilia-Romagna, Via Begarelli, 13, 41121 Modena, Italy
| | - Fabiana Scotto
- Regional Centre for Urban Areas, Arpae Emilia-Romagna, Largo Caduti del Lavoro, 6, 40122 Bologna, Italy
| | - Claudia Zigola
- Provincial District of Ravenna, Arpae Emilia-Romagna, Via Alberoni, 17/19, 48121 Ravenna, Italy
| | - Paolo Lauriola
- Regional Centre for Environment and Health, Arpae Emilia-Romagna, Via Begarelli, 13, 41121 Modena, Italy
| | - Domenico Maria Cavallo
- Department of Science and High Technology, Università degli Studi dell'Insubria, Via Valleggio 11, 22100 Como, Italy
| | - Vanes Poluzzi
- Regional Centre for Urban Areas, Arpae Emilia-Romagna, Largo Caduti del Lavoro, 6, 40122 Bologna, Italy
| | - Andrea Cattaneo
- Department of Science and High Technology, Università degli Studi dell'Insubria, Via Valleggio 11, 22100 Como, Italy
| | - Otto Hänninen
- National Institute for Health and Welfare, Kuopio, Finland
| |
Collapse
|
70
|
Cui L, Duo B, Zhang F, Li C, Fu H, Chen J. Physiochemical characteristics of aerosol particles collected from the Jokhang Temple indoors and the implication to human exposure. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2018; 236:992-1003. [PMID: 29452713 DOI: 10.1016/j.envpol.2017.10.107] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2017] [Revised: 10/24/2017] [Accepted: 10/24/2017] [Indexed: 06/08/2023]
Abstract
This paper presents a detailed study on the indoor air pollution in the Jokahng Temple at Tibet Plateau, and its implication to human health. The mean concentrations of PM1.0 and PM2.5 were 435.0 ± 309.5 and 483.0 ± 284.9 μg/m3, respectively. The PM2.5 concentration exceeded the National Ambient Air Quality Standard (75 μg/m3) by 6.4 times. The size-segregated aerosols displayed a bimodal distribution. One peak was observed in the fine mode (0.4-2.1 μm) and the other peak appeared in the coarse mode (2.1-9.0 μm). The concentration of the total size-resolved PM was 794.3 ± 84.9 μg/m3. The mass fraction of coarse particles shared by 41.1%, apparently higher than that reported at low altitudes, probably due to incomplete combustion at Tibet Plateau with hypoxic atmospheric environment. The total concentration of polycyclic aromatic hydrocarbons (PAHs) was 331.2 ± 60.3 ng/m3, in which the concentration of benzo(a)pyrene (BaP) was 18.5 ± 4.3 ng/m3, over ten times higher than the maximum permissible risk value of 1 ng/m3 on account of carcinogenic potency of particulate PAHs through inhalation. PAHs exhibited a trimodal distribution, of which two peaks were observed in the fine mode and one peak in the coarse mode. With the aromatic rings increasing, the peak intensity increased in the fine mode. Na, Ca, Al, Mg and K dominated the elemental mass profiles, and metals displayed a bimodal distribution with a dominant peak in the coarse range. The total PAH deposition flux was 123.6 and 53.1 ng/h for adults and children, respectively. Coarse particles contributed most deposition flux in the head region, while fine particles contribute most deposition flux in the alveolar region. The increment lifetime cancer risk (ILCR) of PAHs ranaged at 10-5-10-4, indicating potential cancer risk to human health. The total deposition flux of metals was estimated at 1.4-13.2 ng/h. With the size increasing, deposition flux increased in the head region while decreased in the alveolar region. The highest ILCR of Cr and Ni were 4.9 × 10-5 and 1.5 × 10-6, respectively, exceeding the permissible risk of 10-6. The hazard quotient (HQ) of Fe (10-5-10-4) and Zn (10-6-10-5) were much lower than the safe level of 1.0, and thus they were not considered as a health concern.
Collapse
Affiliation(s)
- Lulu Cui
- Shanghai Key Laboratory of Atmospheric Particle Pollution and Prevention, Department of Environmental Science & Engineering, Institute of Atmospheric Sciences, Fudan University, Shanghai, 200433, China
| | - Bu Duo
- Shanghai Key Laboratory of Atmospheric Particle Pollution and Prevention, Department of Environmental Science & Engineering, Institute of Atmospheric Sciences, Fudan University, Shanghai, 200433, China; Department of Chemistry& Environmental Science, Tibet University, Lhasa 850000, China
| | - Fei Zhang
- Shanghai Key Laboratory of Atmospheric Particle Pollution and Prevention, Department of Environmental Science & Engineering, Institute of Atmospheric Sciences, Fudan University, Shanghai, 200433, China
| | - Chunlin Li
- Shanghai Key Laboratory of Atmospheric Particle Pollution and Prevention, Department of Environmental Science & Engineering, Institute of Atmospheric Sciences, Fudan University, Shanghai, 200433, China
| | - Hongbo Fu
- Shanghai Key Laboratory of Atmospheric Particle Pollution and Prevention, Department of Environmental Science & Engineering, Institute of Atmospheric Sciences, Fudan University, Shanghai, 200433, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai, 200092, China; Collaborative Innovation Center of Atmospheric Environment and Equipment Technology(CICAEET), Nanjing University of Information Science and Technology, Nanjing, 210044, China
| | - Jianmin Chen
- Shanghai Key Laboratory of Atmospheric Particle Pollution and Prevention, Department of Environmental Science & Engineering, Institute of Atmospheric Sciences, Fudan University, Shanghai, 200433, China.
| |
Collapse
|
71
|
Evaluating the Sensitivity of the Mass-Based Particle Removal Calculations for HVAC Filters in ISO 16890 to Assumptions for Aerosol Distributions. ATMOSPHERE 2018. [DOI: 10.3390/atmos9030085] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
72
|
Hudda N, Simon M, Zamore W, Durant JL. Aviation-Related Impacts on Ultrafine Particle Number Concentrations Outside and Inside Residences near an Airport. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2018; 52:1765-1772. [PMID: 29411612 PMCID: PMC5822220 DOI: 10.1021/acs.est.7b05593] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Jet engine exhaust is a significant source of ultrafine particles and aviation-related emissions can adversely impact air quality over large areas surrounding airports. We investigated outdoor and indoor ultrafine particle number concentrations (PNC) from 16 residences located in two study areas in the greater Boston metropolitan area (MA, USA) for evidence of aviation-related impacts. During winds from the direction of Logan International Airport, that is, impact-sector winds, an increase in outdoor and indoor PNC was clearly evident at all seven residences in the Chelsea study area (∼4-5 km from the airport) and three out of nine residences in the Boston study area (∼5-6 km from the airport); the median increase during impact-sector winds compared to other winds was 1.7-fold for both outdoor and indoor PNC. Across all residences during impact-sector and other winds, median outdoor PNC were 19 000 and 10 000 particles/cm3, respectively, and median indoor PNC were 7000 and 4000 particles/cm3, respectively. Overall, our results indicate that aviation-related outdoor PNC infiltrate indoors and result in significantly higher indoor PNC. Our study provides compelling evidence for the impact of aviation-related emissions on residential exposures. Further investigation is warranted because these impacts are not expected to be unique to Logan airport.
Collapse
Affiliation(s)
- N. Hudda
- Department
of Civil and Environmental Engineering, Tufts University, 200
College Ave, 204 Anderson Hall, Medford, Massachusetts 02155, United States
- Phone: 617.627.5489; fax: 617.627.3994; e-mail:
| | - M.C. Simon
- Department
of Civil and Environmental Engineering, Tufts University, 200
College Ave, 204 Anderson Hall, Medford, Massachusetts 02155, United States
- Department
of Environmental Health, Boston University, 715 Albany Street, Boston, Massachusetts 02118, United States
| | - W. Zamore
- Somerville
Transportation Equity Partnership, 13 Highland Ave, #3, Somerville, Massachusetts 02143, United States
| | - J. L. Durant
- Department
of Civil and Environmental Engineering, Tufts University, 200
College Ave, 204 Anderson Hall, Medford, Massachusetts 02155, United States
| |
Collapse
|
73
|
Zhou X, Cai J, Zhao Y, Chen R, Wang C, Zhao A, Yang C, Li H, Liu S, Cao J, Kan H, Xu H. Estimation of residential fine particulate matter infiltration in Shanghai, China. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2018; 233:494-500. [PMID: 29102879 DOI: 10.1016/j.envpol.2017.10.054] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/02/2017] [Revised: 10/11/2017] [Accepted: 10/13/2017] [Indexed: 06/07/2023]
Abstract
Ambient concentrations of fine particulate matter (PM2.5) concentration is often used as an exposure surrogate to estimate PM2.5 health effects in epidemiological studies. Ignoring the potential variations in the amount of outdoor PM2.5 infiltrating into indoor environments will cause exposure misclassification, especially when people spend most of their time indoors. As it is not feasible to measure the PM2.5 infiltration factor (Finf) for each individual residence, we aimed to build models for residential PM2.5Finf prediction and to evaluate seasonal Finf variations among residences. We repeated collected paired indoor and outdoor PM2.5 filter samples for 7 continuous days in each of the three seasons (hot, cold and transitional seasons) from 48 typical homes of Shanghai, China. PM2.5-bound sulfur on the filters was measured by X-ray fluorescence for PM2.5Finf calculation. We then used stepwise-multiple linear regression to construct season-specific models with climatic variables and questionnaire-based predictors. All models were evaluated by the coefficient of determination (R2) and root mean square error (RMSE) from a leave-one-out-cross-validation (LOOCV). The 7-day mean (±SD) of PM2.5Finf across all observations was 0.83 (±0.18). Finf was found higher and more varied in transitional season (12-25 °C) than hot (>25 °C) and cold (<12 °C) seasons. Air conditioning use and meteorological factors were the most important predictors during hot and cold seasons; Floor of residence and building age were the best transitional season predictors. The models predicted 60.0%-68.4% of the variance in 7-day averages of Finf, The LOOCV analysis showed an R2 of 0.52 and an RMSE of 0.11. Our finding of large variation in residential PM2.5Finf between seasons and across residences within season indicated the important source of outdoor-generated PM2.5 exposure heterogeneity in epidemiologic studies. Our models based on readily available data may potentially improve the accuracy of estimates of the health effects of PM2.5 exposure.
Collapse
Affiliation(s)
- Xiaodan Zhou
- School of Public Health, Key Laboratory of Public Health Safety of the Ministry of Education, Key Laboratory of Health Technology Assessment of the Ministry of Health, Fudan University, Shanghai, China; Environmental Health Department, Shanghai Municipal Center for Disease Control and Prevention, Shanghai, China
| | - Jing Cai
- School of Public Health, Key Laboratory of Public Health Safety of the Ministry of Education, Key Laboratory of Health Technology Assessment of the Ministry of Health, Fudan University, Shanghai, China; Shanghai Key Laboratory of Meteorology and Health, Shanghai, China
| | - Yan Zhao
- Shanghai First Maternity and Infant Hospital, Tongji University School of Medicine, Shanghai, China
| | - Renjie Chen
- School of Public Health, Key Laboratory of Public Health Safety of the Ministry of Education, Key Laboratory of Health Technology Assessment of the Ministry of Health, Fudan University, Shanghai, China
| | - Cuicui Wang
- School of Public Health, Key Laboratory of Public Health Safety of the Ministry of Education, Key Laboratory of Health Technology Assessment of the Ministry of Health, Fudan University, Shanghai, China
| | - Ang Zhao
- School of Public Health, Key Laboratory of Public Health Safety of the Ministry of Education, Key Laboratory of Health Technology Assessment of the Ministry of Health, Fudan University, Shanghai, China; Environmental & Occupational Health Evaluation Department, Shanghai Municipal Center for Disease Control & Prevention, Shanghai, China
| | - Changyuan Yang
- School of Public Health, Key Laboratory of Public Health Safety of the Ministry of Education, Key Laboratory of Health Technology Assessment of the Ministry of Health, Fudan University, Shanghai, China
| | - Huichu Li
- School of Public Health, Key Laboratory of Public Health Safety of the Ministry of Education, Key Laboratory of Health Technology Assessment of the Ministry of Health, Fudan University, Shanghai, China
| | - Suixin Liu
- Institute of Earth Environment, Chinese Academy of Sciences, Xian, China
| | - Junji Cao
- Institute of Earth Environment, Chinese Academy of Sciences, Xian, China
| | - Haidong Kan
- School of Public Health, Key Laboratory of Public Health Safety of the Ministry of Education, Key Laboratory of Health Technology Assessment of the Ministry of Health, Fudan University, Shanghai, China.
| | - Huihui Xu
- Environmental Health Department, Shanghai Municipal Center for Disease Control and Prevention, Shanghai, China.
| |
Collapse
|
74
|
Zhu YS, Yang WD, Li XW, Ni HG, Zeng H. Airborne particle-bound brominated flame retardants: Levels, size distribution and indoor-outdoor exchange. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2018; 233:1104-1112. [PMID: 29033174 DOI: 10.1016/j.envpol.2017.10.013] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2017] [Revised: 10/03/2017] [Accepted: 10/05/2017] [Indexed: 06/07/2023]
Abstract
The quality of indoor environments has a significant impact on public health. Usually, an indoor environment is treated as a static box, in which physicochemical reactions of indoor air contaminants are negligible. This results in conservative estimates for primary indoor air pollutant concentrations, while also ignoring secondary pollutants. Thus, understanding the relationship between indoor and outdoor particles and particle-bound pollutants is of great significance. For this reason, we collected simultaneous indoor and outdoor measurements of the size distribution of airborne brominated flame retardant (BFR) congeners. The time-dependent concentrations of indoor particles and particle-bound BFRs were then estimated with the mass balance model, accounting for the outdoor concentration, indoor source strength, infiltration, penetration, deposition and indoor resuspension. Based on qualitative observation, the size distributions of ΣPBDE and ΣHBCD were characterized by bimodal peaks. According to our results, particle-bound BDE209 and γ-HBCD underwent degradation. Regardless of the surface adsorption capability of particles and the physicochemical properties of the target compounds, the concentration of BFRs in particles of different size fractions seemed to be governed by the particle distribution. Based on our estimations, for airborne particles and particle-bound BFRs, a window-open ventilated room only takes a quarter of the time to reach an equilibrium between the concentration of pollutants inside and outside compared to a closed room. Unfortunately, indoor pollutants and outdoor pollutants always exist simultaneously, which poses a window-open-or-closed dilemma to achieve proper ventilation.
Collapse
Affiliation(s)
- Yue-Shan Zhu
- Shenzhen Key Laboratory of Circular Economy, Shenzhen Graduate School, Peking University, Shenzhen 518055, China
| | - Wan-Dong Yang
- Shenzhen Key Laboratory of Circular Economy, Shenzhen Graduate School, Peking University, Shenzhen 518055, China
| | - Xiu-Wen Li
- Shenzhen Key Laboratory of Circular Economy, Shenzhen Graduate School, Peking University, Shenzhen 518055, China
| | - Hong-Gang Ni
- Shenzhen Key Laboratory of Circular Economy, Shenzhen Graduate School, Peking University, Shenzhen 518055, China.
| | - Hui Zeng
- Shenzhen Key Laboratory of Circular Economy, Shenzhen Graduate School, Peking University, Shenzhen 518055, China
| |
Collapse
|
75
|
Bivolarova M, Ondráček J, Melikov A, Ždímal V. A comparison between tracer gas and aerosol particles distribution indoors: The impact of ventilation rate, interaction of airflows, and presence of objects. INDOOR AIR 2017; 27:1201-1212. [PMID: 28378912 DOI: 10.1111/ina.12388] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/04/2016] [Accepted: 04/02/2017] [Indexed: 05/07/2023]
Abstract
The study investigated the separate and combined effects of ventilation rate, free convection flow produced by a thermal manikin, and the presence of objects on the distribution of tracer gas and particles in indoor air. The concentration of aerosol particles and tracer gas was measured in a test room with mixing ventilation. Three layouts were arranged: an empty room, an office room with an occupant sitting in front of a table, and a single-bed hospital room. The room occupant was simulated by a thermal manikin. Monodisperse particles of three sizes (0.07, 0.7, and 3.5 μm) and nitrous oxide tracer gas were generated simultaneously at the same location in the room. The particles and gas concentrations were measured in the bulk room air, in the breathing zone of the manikin, and in the exhaust air. Within the breathing zone of the sitting occupant, the tracer gas emerged as reliable predictor for the exposure to all different-sized test particles. A change in the ventilation rate did not affect the difference in concentration distribution between tracer gas and larger particle sizes. Increasing the room surface area did not influence the similarity in the dispersion of the aerosol particles and the tracer gas.
Collapse
Affiliation(s)
- M Bivolarova
- Department of Civil Engineering, International Centre for Indoor Environment and Energy, Technical University of Denmark, Lyngby, Denmark
| | - J Ondráček
- Laboratory of Aerosol Chemistry and Physics, Institute of Chemical Process Fundamentals of the CAS, Prague, Czech Republic
| | - A Melikov
- Department of Civil Engineering, International Centre for Indoor Environment and Energy, Technical University of Denmark, Lyngby, Denmark
| | - V Ždímal
- Laboratory of Aerosol Chemistry and Physics, Institute of Chemical Process Fundamentals of the CAS, Prague, Czech Republic
| |
Collapse
|
76
|
Chen Y, Li X, Zhu T, Han Y, Lv D. PM 2.5-bound PAHs in three indoor and one outdoor air in Beijing: Concentration, source and health risk assessment. THE SCIENCE OF THE TOTAL ENVIRONMENT 2017; 586:255-264. [PMID: 28187942 DOI: 10.1016/j.scitotenv.2017.01.214] [Citation(s) in RCA: 68] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/12/2016] [Revised: 01/02/2017] [Accepted: 01/31/2017] [Indexed: 06/06/2023]
Abstract
Three indoor (residential home, dormitory, and office) and one outdoor concentrations of PM2.5-bound Polycyclic aromatic hydrocarbons (PAHs) were analyzed in Beijing across four seasons. The highest and lowest concentration of total PAHs for outdoor appeared in winter and in summer with averages of 200.1 and 9.1ng/m3 respectively. The seasonal variations of total PAHs in three indoor sites were the same as outdoor. The correlation analysis between the indoor and outdoor samples showed that the annual mean I/O ratios of total PAHs in the three sites were lower than 1. Source apportionment showed vehicle exhaust, coal combustion, and biomass burning were the major contributors of indoor and outdoor PM2.5-bound PAHs. Indoor source, such as camphor pollution, was identified in the dormitory, while camphor pollution and cooking sources were identified in the residential home. The annual averages of Benzo[a]pyrene equivalent concentration (BaPeq) were 7.6, 7.8, 7.7 and 12.7ng/m3 for the dormitory, office, residential home and outdoor samples respectively, far higher than the annual limit of 1ng/m3 regulated by European Commission. Life lung cancer risk (LLCR) in four sites across four seasons were over the acceptable cancer risk level, showing the cancer risk were at a high level in both indoor and outdoor sites in Beijing, and its level in indoor sites was much lower than in the outdoor site. The health risk assessment indicated the level of PAHs cancer risk on human for three indoor sites were similar. The results call for the development of more stringent control measures to reduce PAHs emissions.
Collapse
Affiliation(s)
- Ying Chen
- School of Space and Environment, Beihang University, Beijing 100191, China
| | - Xinghua Li
- School of Space and Environment, Beihang University, Beijing 100191, China.
| | - Tianle Zhu
- School of Space and Environment, Beihang University, Beijing 100191, China.
| | - Yingjie Han
- School of Space and Environment, Beihang University, Beijing 100191, China
| | - Dong Lv
- School of Space and Environment, Beihang University, Beijing 100191, China
| |
Collapse
|
77
|
Han B, Hu LW, Bai Z. Human Exposure Assessment for Air Pollution. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2017; 1017:27-57. [PMID: 29177958 DOI: 10.1007/978-981-10-5657-4_3] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Assessment of human exposure to air pollution is a fundamental part of the more general process of health risk assessment. The measurement methods for exposure assessment now include personal exposure monitoring, indoor-outdoor sampling, mobile monitoring, and exposure assessment modeling (such as proximity models, interpolation model, air dispersion models, and land-use regression (LUR) models). Among these methods, personal exposure measurement is considered to be the most accurate method of pollutant exposure assessment until now, since it can better quantify observed differences and better reflect exposure among smaller groups of people at ground level. And since the great differences of geographical environment, source distribution, pollution characteristics, economic conditions, and living habits, there is a wide range of differences between indoor, outdoor, and individual air pollution exposure in different regions of China. In general, the indoor particles in most Chinese families comprise infiltrated outdoor particles, particles generated indoors, and a few secondary organic aerosol particles, and in most cases, outdoor particle pollution concentrations are a major contributor to indoor concentrations in China. Furthermore, since the time, energy, and expense are limited, it is difficult to measure the concentration of pollutants for each individual. In recent years, obtaining the concentration of air pollutants by using a variety of exposure assessment models is becoming a main method which could solve the problem of the increasing number of individuals in epidemiology studies.
Collapse
Affiliation(s)
- Bin Han
- State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research Academy of Environmental Sciences, Beijing, 100012, China.,Atmospheric Chemistry & Aerosol Division, Chinese Research Academy of Environmental Sciences, Beijing, China
| | - Li-Wen Hu
- Guangzhou Key Laboratory of Environmental Pollution and Health Risk Assessment, Department of Preventive Medicine, School of Public Health, Sun Yat-sen University, 74 Zhongshan 2nd Road, Yuexiu District,, Guangzhou, 510080, Guangdong, China
| | - Zhipeng Bai
- State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research Academy of Environmental Sciences, Beijing, 100012, China. .,Atmospheric Chemistry & Aerosol Division, Chinese Research Academy of Environmental Sciences, Beijing, China.
| |
Collapse
|
78
|
Shi S, Chen C, Zhao B. Modifications of exposure to ambient particulate matter: Tackling bias in using ambient concentration as surrogate with particle infiltration factor and ambient exposure factor. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2017; 220:337-347. [PMID: 27707596 DOI: 10.1016/j.envpol.2016.09.069] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/07/2016] [Revised: 09/01/2016] [Accepted: 09/23/2016] [Indexed: 06/06/2023]
Abstract
Numerous epidemiological studies explored health risks attributed to outdoor particle pollution. However, a number of these studies routinely utilized ambient concentration as a surrogate for personal exposure to ambient particles. This simplification ignored the difference between indoor and outdoor concentrations of outdoor originated particles and may bias the estimate of particle-health associations. Intending to avoid the bias, particle infiltration factor (Finf), which describes the penetration of outdoor particles in indoor environment, and ambient exposure factor (α), which represents the fraction of outdoor particles people are truly exposed to, are utilized as modification factors to modify outdoor particle concentration. In this study, the probabilistic distributions of annually-averaged and seasonally-averaged Finf and α were assessed for residences and residents in Beijing. Finf of a single residence and α of an individual was estimated based on the mechanisms governing particle outdoor-to-indoor migration and human time-activity pattern. With this as the core deterministic model, probabilistic distributions of Finf and α were estimated via Monte Carlo Simulation. Annually-averaged Finf of PM2.5 and PM10 for residences in Beijing tended to be log-normally distributed as lnN(-0.74,0.14) and lnN(-0.94,0.15) with geometric mean value as 0.47 and 0.39, respectively. Annually-averaged α of PM2.5 and PM10 for Beijing residents also tended to be log-normally distributed as lnN(-0.59,0.12) and lnN(-0.73,0.13) with geometric mean value as 0.55 and 0.48, respectively. As for seasonally-averaged results, Finf and α of PM2.5 and PM10 were largest in summer and smallest in winter. The obvious difference between these modification factors and unity suggested that modifications of ambient particle concentration need to be considered in epidemiological studies to avoid misclassifications of personal exposure to ambient particles. Moreover, considering the inter-individual difference of Finf and α may lead to a brand new perspective of particle-health associations in further epidemiological study.
Collapse
Affiliation(s)
- Shanshan Shi
- Department of Building Science, School of Architecture, Tsinghua University, Beijing 100084, PR China
| | - Chen Chen
- Department of Building Science, School of Architecture, Tsinghua University, Beijing 100084, PR China
| | - Bin Zhao
- Department of Building Science, School of Architecture, Tsinghua University, Beijing 100084, PR China; Beijing Key Laboratory of Indoor Air Quality Evaluation and Control, Tsinghua University, Beijing, China.
| |
Collapse
|
79
|
Zhao H, Stephens B. Using portable particle sizing instrumentation to rapidly measure the penetration of fine and ultrafine particles in unoccupied residences. INDOOR AIR 2017; 27:218-229. [PMID: 26931793 DOI: 10.1111/ina.12295] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/04/2015] [Accepted: 02/25/2016] [Indexed: 06/05/2023]
Abstract
Much of human exposure to particulate matter of outdoor origin occurs inside buildings, particularly in residences. The particle penetration factor through leaks in a building's exterior enclosure assembly is a key parameter that governs the infiltration of outdoor particles. However, experimental data for size-resolved particle penetration factors in real buildings, as well as penetration factors for fine particles less than 2.5 μm (PM2.5 ) and ultrafine particles less than 100 nm (UFPs), remain limited, in part because of previous limitations in instrumentation and experimental methods. Here, we report on the development and application of a modified test method that utilizes portable particle sizing instrumentation to measure size-resolved infiltration factors and envelope penetration factors for 0.01-2.5 μm particles, which are then used to estimate penetration factors for integral measures of UFPs and PM2.5 . Eleven replicate measurements were made in an unoccupied apartment unit in Chicago, IL to evaluate the accuracy and repeatability of the test procedure and solution methods. Mean estimates of size-resolved penetration factors ranged from 0.41 ± 0.14 to 0.73 ± 0.05 across the range of measured particle sizes, while mean estimates of penetration factors for integral measures of UFPs and PM2.5 were 0.67 ± 0.05 and 0.73 ± 0.05, respectively. Average relative uncertainties for all particle sizes/classes were less than 20%.
Collapse
Affiliation(s)
- H Zhao
- Department of Civil, Architectural and Environmental Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - B Stephens
- Department of Civil, Architectural and Environmental Engineering, Illinois Institute of Technology, Chicago, IL, USA
| |
Collapse
|
80
|
Lee BH, Yee SW, Kang DH, Yeo MS, Kim KW. Multi-zone simulation of outdoor particle penetration and transport in a multi-story building. BUILDING SIMULATION 2016; 10:525-534. [PMID: 32218899 PMCID: PMC7090779 DOI: 10.1007/s12273-016-0340-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/30/2016] [Revised: 10/30/2016] [Accepted: 10/31/2016] [Indexed: 05/03/2023]
Abstract
In areas with poor ambient air quality, indoor particle concentrations can be significantly affected by particulate matter originating outdoors. The indoor environments of multi-zone and multi-story buildings are affected differently by outdoor particles compared with single-family houses, because of the buildings' more complicated airflow characteristics. The objective of this study is to analyze outdoor particle penetration and transport, and their impact on indoor air, in a multi-zone and multi-story building using a CONTAMW simulation. For the airflow and particle transport analysis, the building leakage, penetration coefficients, and deposition rates were determined by on-site experiments. The results of airflow simulations for cold winters show that outdoor air infiltrates through the lower part of building and exfiltrates from the upper part. The results of the particle simulation also indicated that the airflow characteristics, combined with deposition rates, cause the lower floors of a multi-story building to be exposed to higher fine particle concentrations compared with the upper floors of the building. The study demonstrated that the CONTAMW simulation can be useful in analyzing the impact of outdoor particles on indoor environments through the identification of key particle transport parameters and validated airflow simulations.
Collapse
Affiliation(s)
- Byung Hee Lee
- Department of Architecture and Architectural Engineering, Graduate School of Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul, 08826 Republic of Korea
| | - Su Whan Yee
- Ecoenergy Research Institute, Building of Mechanical Part & Material Testing Busan Tecno Park, 30, Gwahaksandan 1-ro 60beon-gil, Gangseo-gu, Busan, 46742 Republic of Korea
| | - Dong Hwa Kang
- Department of Architectural Engineering, College of Urban Sciences, University of Seoul, 163 Seoulsiripdae-ro, Dongdaemun-gu, Seoul, 02504 Republic of Korea
| | - Myoung Souk Yeo
- Department of Architecture and Architectural Engineering, College of Engineering, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul, 08826 Republic of Korea
| | - Kwang Woo Kim
- Department of Architecture and Architectural Engineering, College of Engineering, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul, 08826 Republic of Korea
| |
Collapse
|
81
|
Hodas N, Loh M, Shin HM, Li D, Bennett D, McKone TE, Jolliet O, Weschler CJ, Jantunen M, Lioy P, Fantke P. Indoor inhalation intake fractions of fine particulate matter: review of influencing factors. INDOOR AIR 2016; 26:836-856. [PMID: 26562829 DOI: 10.1111/ina.12268] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2015] [Accepted: 11/02/2015] [Indexed: 05/21/2023]
Abstract
Exposure to fine particulate matter (PM2.5 ) is a major contributor to the global human disease burden. The indoor environment is of particular importance when considering the health effects associated with PM2.5 exposures because people spend the majority of their time indoors and PM2.5 exposures per unit mass emitted indoors are two to three orders of magnitude larger than exposures to outdoor emissions. Variability in indoor PM2.5 intake fraction (iFin,total ), which is defined as the integrated cumulative intake of PM2.5 per unit of emission, is driven by a combination of building-specific, human-specific, and pollutant-specific factors. Due to a limited availability of data characterizing these factors, however, indoor emissions and intake of PM2.5 are not commonly considered when evaluating the environmental performance of product life cycles. With the aim of addressing this barrier, a literature review was conducted and data characterizing factors influencing iFin,total were compiled. In addition to providing data for the calculation of iFin,total in various indoor environments and for a range of geographic regions, this paper discusses remaining limitations to the incorporation of PM2.5 -derived health impacts into life cycle assessments and makes recommendations regarding future research.
Collapse
Affiliation(s)
- N Hodas
- Division of Chemical Engineering, California Institute of Technology, Pasadena, CA, USA
- Department of Environmental Science and Management, Portland State University, Portland, OR, USA
| | - M Loh
- Institute of Occupational Medicine, Edinburgh, UK
| | - H-M Shin
- Department of Public Health Sciences, University of California, Davis, CA, USA
| | - D Li
- Department of Environmental Health Sciences, University of Michigan, Ann Arbor, MI, USA
| | - D Bennett
- Department of Public Health Sciences, University of California, Davis, CA, USA
| | - T E McKone
- School of Public Health, University of California, Berkeley, CA, USA
- Lawrence Berkeley National Laboratory, Berkeley, CA, USA
| | - O Jolliet
- Department of Environmental Health Sciences, University of Michigan, Ann Arbor, MI, USA
| | - C J Weschler
- Environmental and Occupational Health Sciences Institute, Rutgers University, Piscataway, NJ, USA
- International Centre for Indoor Environment and Energy, Technical University of Denmark, Kgs. Lyngby, Denmark
| | - M Jantunen
- Department of Environmental Health, National Institute for Health and Welfare, Helsinki, Finland
| | - P Lioy
- Environmental and Occupational Health Sciences Institute, Rutgers University, Piscataway, NJ, USA
| | - P Fantke
- Department of Management Engineering, Technical University of Denmark, Kgs. Lyngby, Denmark
| |
Collapse
|
82
|
Chen A, Gall ET, Chang VWC. Indoor and outdoor particulate matter in primary school classrooms with fan-assisted natural ventilation in Singapore. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2016; 23:17613-17624. [PMID: 27234837 DOI: 10.1007/s11356-016-6826-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/12/2015] [Accepted: 05/02/2016] [Indexed: 06/05/2023]
Abstract
We conducted multiday continuous monitoring of indoor and outdoor particulate matter (PM) in classrooms with fan-assisted natural ventilation (NV) at five primary schools in Singapore. We monitored size-resolved number concentration of PM with diameter 0.3-10 μm at all schools and alveolar deposited surface area concentrations of PM with diameter 0.01-1.0 μm (SA0.01-1.0) at two schools. Results show that, during the monitoring period, schools closer to expressways and in the downtown area had 2-3 times higher outdoor PM0.3-1.0 number concentrations than schools located in suburban areas. Average indoor SA0.01-1.0 was 115-118 μm(2) cm(-3) during periods of occupancy and 72-87 μm(2) cm(-3) during unoccupied periods. There were close indoor and outdoor correlations for fine PM during both occupied and unoccupied periods (Pearson's r = 0.84-1.0) while the correlations for coarse PM were weak during the occupied periods (r = 0.13-0.74). Across all the schools, the size-resolved indoor/outdoor PM ratios (I/O ratios) were 0.81 to 1.58 and 0.61 to 0.95 during occupied and unoccupied periods, respectively, and average infiltration factors were 0.64 to 0.94. Average PM net emission rates, calculated during periods of occupancy in the classrooms, were lower than or in the lower range of emission rates reported in the literature. This study also reveals that indoor fine and submicron PM predominantly come from outdoor sources, while indoor sources associated with occupancy may be important for coarse PM even when the classrooms have high air exchange rates.
Collapse
Affiliation(s)
- Ailu Chen
- School of Civil and Environmental Engineering, Nanyang Technological University, 50 Nanyang Ave, Singapore, 639798, Singapore
- SinBerBest Program, Berkeley Education Alliance for Research in Singapore (BEARS), 1 CREATE WAY, University Town, 138602, Singapore City, Singapore
| | - Elliott T Gall
- School of Civil and Environmental Engineering, Nanyang Technological University, 50 Nanyang Ave, Singapore, 639798, Singapore
- SinBerBest Program, Berkeley Education Alliance for Research in Singapore (BEARS), 1 CREATE WAY, University Town, 138602, Singapore City, Singapore
- Department of Mechanical and Materials Engineering, Portland State University, Portland, OR, 97201, USA
| | - Victor W C Chang
- School of Civil and Environmental Engineering, Nanyang Technological University, 50 Nanyang Ave, Singapore, 639798, Singapore.
- SinBerBest Program, Berkeley Education Alliance for Research in Singapore (BEARS), 1 CREATE WAY, University Town, 138602, Singapore City, Singapore.
| |
Collapse
|
83
|
Perrino C, Tofful L, Canepari S. Chemical characterization of indoor and outdoor fine particulate matter in an occupied apartment in Rome, Italy. INDOOR AIR 2016; 26:558-570. [PMID: 26184798 DOI: 10.1111/ina.12235] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/19/2015] [Accepted: 07/08/2015] [Indexed: 06/04/2023]
Abstract
The daily concentration and chemical composition of PM2.5 was determined in indoor and outdoor 24-h samples simultaneously collected for a total of 5 weeks during a winter and a summer period in an apartment sited in Rome, Italy. The use of a specifically developed very quiet sampler (<35 dB) allowed the execution of the study while the family living in the apartment led its normal life. The indoor concentration of PM2.5 showed a small seasonal variation, while outdoor values were much higher during the winter study. Outdoor sources were found to contribute significantly to indoor PM concentration especially during the summer, when the apartment was naturally ventilated by opening the windows. During the winter the infiltration of outdoor PM components was lower and mostly regulated by the particle dimensions. Organics displayed In/Out ratios higher than unity during both periods; their indoor production increased significantly during the weekends, where the family stayed mostly at home. PM components were grouped into macrosources (soil, sea, secondary inorganics, traffic, organics). During the summer the main contributions to outdoor PM2.5 came from soil (30%), secondary inorganics (29%) and organics (22%). Organics dominated both indoor PM2.5 during the summer (60%) and outdoor and indoor PM2.5 during the winter (51% and 66%, respectively).
Collapse
Affiliation(s)
- C Perrino
- C.N.R. Institute of Atmospheric Pollution Research, Rome, Italy
| | - L Tofful
- C.N.R. Institute of Atmospheric Pollution Research, Rome, Italy
- Department of Chemistry, Sapienza University of Rome, Rome, Italy
| | - S Canepari
- C.N.R. Institute of Atmospheric Pollution Research, Rome, Italy
- Department of Chemistry, Sapienza University of Rome, Rome, Italy
| |
Collapse
|
84
|
Zhao H, Stephens B. A method to measure the ozone penetration factor in residences under infiltration conditions: application in a multifamily apartment unit. INDOOR AIR 2016; 26:571-581. [PMID: 26114258 DOI: 10.1111/ina.12228] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/04/2015] [Accepted: 06/20/2015] [Indexed: 06/04/2023]
Abstract
Recent experiments have demonstrated that outdoor ozone reacts with materials inside residential building enclosures, potentially reducing indoor exposures to ozone or altering ozone reaction byproducts. However, test methods to measure ozone penetration factors in residences (P) remain limited. We developed a method to measure ozone penetration factors in residences under infiltration conditions and applied it in an unoccupied apartment unit. Twenty-four repeated measurements were made, and results were explored to (i) evaluate the accuracy and repeatability of the new procedure using multiple solution methods, (ii) compare results from 'interference-free' and conventional UV absorbance ozone monitors, and (iii) compare results against those from a previously published test method requiring artificial depressurization. The mean (±s.d.) estimate of P was 0.54 ± 0.10 across a wide range of conditions using the new method with an interference-free monitor; the conventional monitor was unable to yield meaningful results due to relatively high limits of detection. Estimates of P were not clearly influenced by any indoor or outdoor environmental conditions or changes in indoor decay rate constants. This work represents the first known measurements of ozone penetration factors in a residential building operating under natural infiltration conditions and provides a new method for widespread application in buildings.
Collapse
Affiliation(s)
- H Zhao
- Department of Civil, Architectural and Environmental Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - B Stephens
- Department of Civil, Architectural and Environmental Engineering, Illinois Institute of Technology, Chicago, IL, USA
| |
Collapse
|
85
|
Cavaleiro Rufo J, Madureira J, Paciência I, Slezakova K, Pereira MDC, Aguiar L, Teixeira JP, Moreira A, Oliveira Fernandes E. Children exposure to indoor ultrafine particles in urban and rural school environments. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2016; 23:13877-13885. [PMID: 27040535 DOI: 10.1007/s11356-016-6555-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/16/2015] [Accepted: 03/23/2016] [Indexed: 06/05/2023]
Abstract
Extended exposure to ultrafine particles (UFPs) may lead to consequences in children due to their increased susceptibility when compared to older individuals. Since children spend in average 8 h/day in primary schools, assessing the number concentrations of UFPs in these institutions is important in order to evaluate the health risk for children in primary schools caused by indoor air pollution. Thus, the purpose of this study was to assess and determine the sources of indoor UFP number concentrations in urban and rural Portuguese primary schools. Indoor and outdoor ultrafine particle (UFP) number concentrations were measured in six urban schools (US) and two rural schools (RS) located in the north of Portugal, during the heating season. The mean number concentrations of indoor UFPs were significantly higher in urban schools than in rural ones (10.4 × 10(3) and 5.7 × 10(3) pt/cm(3), respectively). Higher UFP levels were associated with higher squared meters per student, floor levels closer to the ground, chalk boards, furniture or floor covering materials made of wood and windows with double-glazing. Indoor number concentrations of ultrafine-particles were inversely correlated with indoor CO2 levels. In the present work, indoor and outdoor concentrations of UFPs in public primary schools located in urban and rural areas were assessed, and the main sources were identified for each environment. The results not only showed that UFP pollution is present in augmented concentrations in US when compared to RS but also revealed some classroom/school characteristics that influence the concentrations of UFPs in primary schools.
Collapse
Affiliation(s)
- João Cavaleiro Rufo
- INEGI, Rua Dr. Roberto Frias, 4200-465, Porto, Portugal.
- Faculty of Medicine of the University of Porto, Al. Prof. Hernâni Monteiro, 4200-319, Porto, Portugal.
- Epidemiology Research Unit - Institute of Public Health (EPIUnit), University of Porto, Rua das Taipas n°135, Porto, 4050-600, Portugal.
| | | | - Inês Paciência
- INEGI, Rua Dr. Roberto Frias, 4200-465, Porto, Portugal
- Faculty of Medicine of the University of Porto, Al. Prof. Hernâni Monteiro, 4200-319, Porto, Portugal
- Epidemiology Research Unit - Institute of Public Health (EPIUnit), University of Porto, Rua das Taipas n°135, Porto, 4050-600, Portugal
| | - Klara Slezakova
- LEPABE, Faculty of Engineering of University of Porto, Rua Dr. Roberto Frias, 4200-465, Porto, Portugal
| | - Maria do Carmo Pereira
- LEPABE, Faculty of Engineering of University of Porto, Rua Dr. Roberto Frias, 4200-465, Porto, Portugal
| | - Lívia Aguiar
- Epidemiology Research Unit - Institute of Public Health (EPIUnit), University of Porto, Rua das Taipas n°135, Porto, 4050-600, Portugal
- National Institute of Health, Rua Alexandre Herculano, 321, 4200-055, Porto, Portugal
| | - João Paulo Teixeira
- Epidemiology Research Unit - Institute of Public Health (EPIUnit), University of Porto, Rua das Taipas n°135, Porto, 4050-600, Portugal
- National Institute of Health, Rua Alexandre Herculano, 321, 4200-055, Porto, Portugal
| | - André Moreira
- Faculty of Medicine of the University of Porto, Al. Prof. Hernâni Monteiro, 4200-319, Porto, Portugal
| | | |
Collapse
|
86
|
Licina D, Bhangar S, Brooks B, Baker R, Firek B, Tang X, Morowitz MJ, Banfield JF, Nazaroff WW. Concentrations and Sources of Airborne Particles in a Neonatal Intensive Care Unit. PLoS One 2016; 11:e0154991. [PMID: 27175913 PMCID: PMC4866781 DOI: 10.1371/journal.pone.0154991] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2016] [Accepted: 04/23/2016] [Indexed: 11/19/2022] Open
Abstract
Premature infants in neonatal intensive care units (NICUs) have underdeveloped immune systems, making them susceptible to adverse health consequences from air pollutant exposure. Little is known about the sources of indoor airborne particles that contribute to the exposure of premature infants in the NICU environment. In this study, we monitored the spatial and temporal variations of airborne particulate matter concentrations along with other indoor environmental parameters and human occupancy. The experiments were conducted over one year in a private-style NICU. The NICU was served by a central heating, ventilation and air-conditioning (HVAC) system equipped with an economizer and a high-efficiency particle filtration system. The following parameters were measured continuously during weekdays with 1-min resolution: particles larger than 0.3 μm resolved into 6 size groups, CO2 level, dry-bulb temperature and relative humidity, and presence or absence of occupants. Altogether, over sixteen periods of a few weeks each, measurements were conducted in rooms occupied with premature infants. In parallel, a second monitoring station was operated in a nearby hallway or at the local nurses' station. The monitoring data suggest a strong link between indoor particle concentrations and human occupancy. Detected particle peaks from occupancy were clearly discernible among larger particles and imperceptible for submicron (0.3-1 μm) particles. The mean indoor particle mass concentrations averaged across the size range 0.3-10 μm during occupied periods was 1.9 μg/m(3), approximately 2.5 times the concentration during unoccupied periods (0.8 μg/m(3)). Contributions of within-room emissions to total PM10 mass in the baby rooms averaged 37-81%. Near-room indoor emissions and outdoor sources contributed 18-59% and 1-5%, respectively. Airborne particle levels in the size range 1-10 μm showed strong dependence on human activities, indicating the importance of indoor-generated particles for infant's exposure to airborne particulate matter in the NICU.
Collapse
Affiliation(s)
- Dusan Licina
- Department of Civil and Environmental Engineering, University of California, Berkeley, California, United States of America
| | - Seema Bhangar
- Department of Civil and Environmental Engineering, University of California, Berkeley, California, United States of America
| | - Brandon Brooks
- Department of Earth and Planetary Sciences, University of California, Berkeley, California, United States of America
| | - Robyn Baker
- Division of Newborn Medicine, Magee-Womens Hospital of UPMC, Pittsburgh, Pennsylvania, United States of America
| | - Brian Firek
- Department of Surgery, University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania, United States of America
| | - Xiaochen Tang
- Department of Civil and Environmental Engineering, University of California, Berkeley, California, United States of America
| | - Michael J. Morowitz
- Department of Surgery, University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania, United States of America
- Division of Pediatric Surgery, Children's Hospital of Pittsburgh, Pittsburgh, Pennsylvania, United States of America
| | - Jillian F. Banfield
- Department of Earth and Planetary Sciences, University of California, Berkeley, California, United States of America
| | - William W. Nazaroff
- Department of Civil and Environmental Engineering, University of California, Berkeley, California, United States of America
| |
Collapse
|
87
|
Breen MS, Long TC, Schultz BD, Williams RW, Richmond-Bryant J, Breen M, Langstaff JE, Devlin RB, Schneider A, Burke JM, Batterman SA, Meng QY. Air Pollution Exposure Model for Individuals (EMI) in Health Studies: Evaluation for Ambient PM2.5 in Central North Carolina. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2015; 49:14184-14194. [PMID: 26561729 DOI: 10.1021/acs.est.5b02765] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
Air pollution health studies of fine particulate matter (diameter ≤2.5 μm, PM2.5) often use outdoor concentrations as exposure surrogates. Failure to account for variability of indoor infiltration of ambient PM2.5 and time indoors can induce exposure errors. We developed and evaluated an exposure model for individuals (EMI), which predicts five tiers of individual-level exposure metrics for ambient PM2.5 using outdoor concentrations, questionnaires, weather, and time-location information. We linked a mechanistic air exchange rate (AER) model to a mass-balance PM2.5 infiltration model to predict residential AER (Tier 1), infiltration factors (Tier 2), indoor concentrations (Tier 3), personal exposure factors (Tier 4), and personal exposures (Tier 5) for ambient PM2.5. Using cross-validation, individual predictions were compared to 591 daily measurements from 31 homes (Tiers 1-3) and participants (Tiers 4-5) in central North Carolina. Median absolute differences were 39% (0.17 h(-1)) for Tier 1, 18% (0.10) for Tier 2, 20% (2.0 μg/m(3)) for Tier 3, 18% (0.10) for Tier 4, and 20% (1.8 μg/m(3)) for Tier 5. The capability of EMI could help reduce the uncertainty of ambient PM2.5 exposure metrics used in health studies.
Collapse
Affiliation(s)
- Michael S Breen
- National Exposure Research Laboratory, U.S. Environmental Protection Agency, Research Triangle Park, North Carolina 27709, United States
| | - Thomas C Long
- National Center for Environmental Assessment, U.S. Environmental Protection Agency, Research Triangle Park, North Carolina 27709, United States
| | - Bradley D Schultz
- U.S. Environmental Protection Agency, Research Triangle Park, North Carolina 27709, United States
| | - Ronald W Williams
- National Exposure Research Laboratory, U.S. Environmental Protection Agency, Research Triangle Park, North Carolina 27709, United States
| | - Jennifer Richmond-Bryant
- National Center for Environmental Assessment, U.S. Environmental Protection Agency, Research Triangle Park, North Carolina 27709, United States
| | - Miyuki Breen
- Biomathematics Program, Department of Mathematics, North Carolina State University , Raleigh, North Carolina 27695, United States
| | - John E Langstaff
- Office of Air Quality Planning and Standards, U.S. Environmental Protection Agency, Research Triangle Park, North Carolina 27709, United States
| | - Robert B Devlin
- National Health and Environmental Effects Research Laboratory, U.S. Environmental Protection Agency, Research Triangle Park, North Carolina 27709, United States
| | - Alexandra Schneider
- Helmholtz Zentrum Muenchen, German Research Center for Environmental Health, Institute of Epidemiology II , Neuherberg, Germany
| | - Janet M Burke
- National Exposure Research Laboratory, U.S. Environmental Protection Agency, Research Triangle Park, North Carolina 27709, United States
| | - Stuart A Batterman
- Environmental Health Sciences, University of Michigan , Ann Arbor, Michigan 48109, United States
| | - Qing Yu Meng
- Department of Environmental Sciences, Rutgers University , New Brunswick, New Jersey 08901, United States
| |
Collapse
|
88
|
Zhao Y, Wang F, Zhao J. Size-Resolved Ultrafine Particle Deposition and Brownian Coagulation from Gasoline Vehicle Exhaust in an Environmental Test Chamber. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2015; 49:12153-12160. [PMID: 26402743 DOI: 10.1021/acs.est.5b02455] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Size-resolved deposition rates and Brownian coagulation of particles between 20 and 900 nm (mobility diameter) were estimated in a well-mixed environmental chamber from a gasoline vehicle exhaust with a total peak particle concentration of 10(5)-10(6) particles/cm(3) at 12.24-25.22 °C. A deposition theory with modified friction velocity and coagulation model was also employed to predict particle concentration decay. Initially during particle decay, approximately 85% or more of the particles had diameters of <100 nm. Particle deposition rates with standard deviations were highly dependent on particle size ranges, and varied from 0.012 ± 0.003 to 0.48 ± 0.02 h(-1). In the experiment, the friction velocity obtained was in the range 1.5-2.5 cm/s. The most explainable fractal dimension and Hamaker constant in coagulation model were 2.5-3 and 20 kT, respectively, and the contribution from coagulation dominated the total particle decay during the first 1 h of decay. It is considered that the modified friction velocity and best fitted fractal dimension and Hamaker constants could be further used to analyze gasoline vehicle exhaust particle dynamics and assess human exposure to vehicle particle pollutants in urban areas, tunnels, and underground parking lots.
Collapse
Affiliation(s)
- Yu Zhao
- School of Municipal & Environmental Engineering, Harbin Institute of Technology , Harbin 150090, China
| | - Fang Wang
- School of Municipal & Environmental Engineering, Harbin Institute of Technology , Harbin 150090, China
| | - Jianing Zhao
- School of Municipal & Environmental Engineering, Harbin Institute of Technology , Harbin 150090, China
| |
Collapse
|
89
|
Han Y, Qi M, Chen Y, Shen H, Liu J, Huang Y, Chen H, Liu W, Wang X, Liu J, Xing B, Tao S. Influences of ambient air PM₂.₅ concentration and meteorological condition on the indoor PM₂.₅ concentrations in a residential apartment in Beijing using a new approach. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2015; 205:307-14. [PMID: 26123719 DOI: 10.1016/j.envpol.2015.04.026] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/07/2015] [Revised: 04/23/2015] [Accepted: 04/24/2015] [Indexed: 05/13/2023]
Abstract
PM2.5 concentrations in a typical residential apartment in Beijing and immediately outside of the building were measured simultaneously during heating and non-heating periods. The objective was to quantitatively explore the relationship between indoor and outdoor PM2.5 concentrations. A statistical method for predicting indoor PM2.5 concentrations was proposed. Ambient PM2.5 concentrations were strongly affected by meteorological conditions, especially wind directions. A bimodal distribution was identified during the heating season due to the frequent and rapid transition between severe pollution events and clean days. Indoor PM2.5 concentrations were significantly correlated with outdoor PM2.5 concentrations but with 1-2 h delay, and the differences can be explained by ambient meteorological features, such as temperature, humidity, and wind direction. These results indicate the potential to incorporate indoor exposure features to the regional air quality model framework and to more accurately estimate the epidemiological relationship between human mortality and air pollution exposure.
Collapse
Affiliation(s)
- Yang Han
- Laboratory for Earth Surface Processes, College of Urban and Environmental Sciences, Peking University, Beijing, 100871, PR China
| | - Meng Qi
- Laboratory for Earth Surface Processes, College of Urban and Environmental Sciences, Peking University, Beijing, 100871, PR China
| | - Yilin Chen
- Laboratory for Earth Surface Processes, College of Urban and Environmental Sciences, Peking University, Beijing, 100871, PR China
| | - Huizhong Shen
- Laboratory for Earth Surface Processes, College of Urban and Environmental Sciences, Peking University, Beijing, 100871, PR China
| | - Jing Liu
- Laboratory for Earth Surface Processes, College of Urban and Environmental Sciences, Peking University, Beijing, 100871, PR China
| | - Ye Huang
- Laboratory for Earth Surface Processes, College of Urban and Environmental Sciences, Peking University, Beijing, 100871, PR China
| | - Han Chen
- Laboratory for Earth Surface Processes, College of Urban and Environmental Sciences, Peking University, Beijing, 100871, PR China
| | - Wenxin Liu
- Laboratory for Earth Surface Processes, College of Urban and Environmental Sciences, Peking University, Beijing, 100871, PR China
| | - Xilong Wang
- Laboratory for Earth Surface Processes, College of Urban and Environmental Sciences, Peking University, Beijing, 100871, PR China
| | - Junfeng Liu
- Laboratory for Earth Surface Processes, College of Urban and Environmental Sciences, Peking University, Beijing, 100871, PR China
| | - Baoshan Xing
- Stockbridge School of Agriculture, University of Massachusetts, Amherst, MA, 01003, USA
| | - Shu Tao
- Laboratory for Earth Surface Processes, College of Urban and Environmental Sciences, Peking University, Beijing, 100871, PR China.
| |
Collapse
|
90
|
Huang L, Pu Z, Li M, Sundell J. Characterizing the Indoor-Outdoor Relationship of Fine Particulate Matter in Non-Heating Season for Urban Residences in Beijing. PLoS One 2015; 10:e0138559. [PMID: 26397734 PMCID: PMC4580321 DOI: 10.1371/journal.pone.0138559] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2015] [Accepted: 09/01/2015] [Indexed: 11/19/2022] Open
Abstract
OBJECTIVE Ambient fine particulate matter (PM2.5) pollution is currently a major public health concern in Chinese urban areas. However, PM2.5 exposure primarily occurs indoors. Given such, we conducted this study to characterize the indoor-outdoor relationship of PM2.5 mass concentrations for urban residences in Beijing. METHODS In this study, 24-h real-time indoor and ambient PM2.5 mass concentrations were concurrently collected for 41 urban residences in the non-heating season. The diurnal variation of pollutant concentrations was characterized. Pearson correlation analysis was used to examine the correlation between indoor and ambient PM2.5 mass concentrations. Regression analysis with ordinary least square was employed to characterize the influences of a variety of factors on PM2.5 mass concentration. RESULTS Hourly ambient PM2.5 mass concentrations were 3-280 μg/m3 with a median of 58 μg/m3, and hourly indoor counterpart were 4-193 μg/m3 with a median of 34 μg/m3. The median indoor/ambient ratio of PM2.5 mass concentration was 0.62. The diurnal variation of residential indoor and ambient PM2.5 mass concentrations tracked with each other well. Strong correlation was found between indoor and ambient PM2.5 mass concentrations on the community basis (coefficients: r ≥ 0.90, p < 0.0001), and the ambient data explained ≥ 84% variance of the indoor data. Regression analysis suggested that the variables, such as traffic conditions, indoor smoking activities, indoor cleaning activities, indoor plants and number of occupants, had significant influences on the indoor PM2.5 mass concentrations. CONCLUSIONS PM2.5 of ambient origin made dominant contribution to residential indoor PM2.5 exposure in the non-heating season under the high ambient fine particle pollution condition. Nonetheless, the large inter-residence variability of infiltration factor of ambient PM2.5 raised the concern of exposure misclassification when using ambient PM2.5 mass concentrations as exposure surrogates. PM2.5 of indoor origin still had minor influence on indoor PM2.5 mass concentrations, particularly at 11:00-13:00 and 22:00-0:00. The predictive models suggested that particles from traffic emission, secondary aerosols, particles from indoor smoking, resuspended particles due to indoor cleaning and particles related to indoor plants contributed to indoor PM2.5 mass concentrations in this study. Real-time ventilation measurements and improvement of questionnaire design to involve more variables subject to built environment were recommended to enhance the performance of the predictive models.
Collapse
Affiliation(s)
- Lihui Huang
- Key Laboratory of Subsurface Hydrology and Ecological Effects in Arid Region, Ministry of Education, School of Environmental Science and Engineering, Chang’an University, Xi’an, 710054, China
- Institute of Built Environment, Department of Building Science, Tsinghua University, Beijing, 100084, China
| | - Zhongnan Pu
- Institute of Built Environment, Department of Building Science, Tsinghua University, Beijing, 100084, China
| | - Mu Li
- Institute of Built Environment, Department of Building Science, Tsinghua University, Beijing, 100084, China
| | - Jan Sundell
- Institute of Built Environment, Department of Building Science, Tsinghua University, Beijing, 100084, China
| |
Collapse
|
91
|
Rösch C, Wissenbach DK, von Bergen M, Franck U, Wendisch M, Schlink U. The lasting effect of limonene-induced particle formation on air quality in a genuine indoor environment. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2015; 22:14209-14219. [PMID: 25966888 DOI: 10.1007/s11356-015-4663-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/24/2014] [Accepted: 05/04/2015] [Indexed: 06/04/2023]
Abstract
Atmospheric ozone-terpene reactions, which form secondary organic aerosol (SOA) particles, can affect indoor air quality when outdoor air mixes with indoor air during ventilation. This study, conducted in Leipzig, Germany, focused on limonene-induced particle formation in a genuine indoor environment (24 m(3)). Particle number, limonene and ozone concentrations were monitored during the whole experimental period. After manual ventilation for 30 min, during which indoor ozone levels reached up to 22.7 ppb, limonene was introduced into the room at concentrations of approximately 180 to 250 μg m(-3). We observed strong particle formation and growth within a diameter range of 9 to 50 nm under real-room conditions. Larger particles with diameters above 100 nm were less affected by limonene introduction. The total particle number concentrations (TPNCs) after limonene introduction clearly exceed outdoor values by a factor of 4.5 to 41 reaching maximum concentrations of up to 267,000 particles cm(-3). The formation strength was influenced by background particles, which attenuated the formation of new SOA with increasing concentration, and by ozone levels, an increase of which by 10 ppb will result in a six times higher TPNC. This study emphasizes indoor environments to be preferred locations for particle formation and growth after ventilation events. As a consequence, SOA formation can produce significantly higher amounts of particles than transported by ventilation into the indoor air.
Collapse
Affiliation(s)
- Carolin Rösch
- Department of Urban and Environmental Sociology, Helmholtz Centre for Environmental Research - UFZ, Permoserstrasse 15, 04318, Leipzig, Germany,
| | | | | | | | | | | |
Collapse
|
92
|
You S, Wan MP. A Risk Assessment Scheme of Infection Transmission Indoors Incorporating the Impact of Resuspension. RISK ANALYSIS : AN OFFICIAL PUBLICATION OF THE SOCIETY FOR RISK ANALYSIS 2015; 35:1488-1502. [PMID: 25808677 DOI: 10.1111/risa.12350] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
A new risk assessment scheme was developed to quantify the impact of resuspension to infection transmission indoors. Airborne and surface pathogenic particle concentration models including the effect of two major resuspension scenarios (airflow-induced particle resuspension [AIPR] and walking-induced particle resuspension [WIPR]) were derived based on two-compartment mass balance models and validated against experimental data found in the literature. The inhalation exposure to pathogenic particles was estimated using the derived airborne concentration model, and subsequently incorporated into a dose-response model to assess the infection risk. Using the proposed risk assessment scheme, the influences of resuspension towards indoor infection transmission were examined by two hypothetical case studies. In the case of AIPR, the infection risk increased from 0 to 0.54 during 0-0.5 hours and from 0.54 to 0.57 during 0.5-4 hours. In the case of WIPR, the infection risk increased from 0 to 0.87 during 0-0.5 hours and from 0.87 to 1 during 0.5-4 hours. Sensitivity analysis was conducted based on the design-of-experiments method and showed that the factors that are related to the inspiratory rate of viable pathogens and pathogen virulence have the most significant effect on the infection probability under the occurrence of AIPR and WIPR. The risk assessment scheme could serve as an effective tool for the risk assessment of infection transmission indoors.
Collapse
Affiliation(s)
- Siming You
- Department of Civil & Environmental Engineering, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Man Pun Wan
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, Nanyang, Singapore
| |
Collapse
|
93
|
A Randomized Cross-over Air Filtration Intervention Trial for Reducing Cardiovascular Health Risks in Residents of Public Housing near a Highway. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2015; 12:7814-38. [PMID: 26184257 PMCID: PMC4515693 DOI: 10.3390/ijerph120707814] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/22/2015] [Revised: 06/11/2015] [Accepted: 07/02/2015] [Indexed: 11/17/2022]
Abstract
Exposure to traffic-generated ultrafine particles (UFP; particles <100 nm) is likely a risk factor for cardiovascular disease. We conducted a trial of high-efficiency particulate arrestance (HEPA) filtration in public housing near a highway. Twenty residents in 19 apartments living <200 m from the highway participated in a randomized, double-blind crossover trial. A HEPA filter unit and a particle counter (measuring particle number concentration (PNC), a proxy for UFP) were installed in living rooms. Participants were exposed to filtered air for 21 days and unfiltered air for 21 days. Blood samples were collected and blood pressure measured at days 0, 21 and 42 after a 12-hour fasting period. Plasma was analyzed for high sensitivity C-reactive protein (hsCRP), interleukin-6 (IL-6), tumor necrosis factor alpha-receptor II (TNF-RII) and fibrinogen. PNC reductions ranging from 21% to 68% were recorded in 15 of the apartments. We observed no significant differences in blood pressure or three of the four biomarkers (hsCRP, fibrinogen, and TNF-RII) measured in participants after 21-day exposure to HEPA-filtered air compared to measurements after 21-day exposure to sham-filtered air. In contrast, IL-6 concentrations were significantly higher following HEPA filtration (0.668 pg/mL; CI = 0.465-0.959) compared to sham filtration. Likewise, PNC adjusted for time activity were associated with increasing IL-6 in 14- and 21-day moving averages, and PNC was associated with decreasing blood pressure in Lags 0, 1 and 2, and in a 3-day moving average. These negative associations were unexpected and could be due to a combination of factors including exposure misclassification, unsuccessful randomization (i.e., IL-6 and use of anti-inflammatory medicines), or uncontrolled confounding. Studies with greater reduction in UFP levels and larger sample sizes are needed. There also needs to be more complete assessment of resident time activity and of outdoor vs. indoor source contributions to UFP exposure. HEPA filtration remains a promising, but not fully realized intervention.
Collapse
|
94
|
Insights into Indoor/Outdoor PM Concentration Ratios due to Dust Storms in an Arid Region. ATMOSPHERE 2015. [DOI: 10.3390/atmos6070879] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
95
|
Ji W, Zhao B. Estimating mortality derived from indoor exposure to particles of outdoor origin. PLoS One 2015; 10:e0124238. [PMID: 25860147 PMCID: PMC4393180 DOI: 10.1371/journal.pone.0124238] [Citation(s) in RCA: 53] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2014] [Accepted: 03/05/2015] [Indexed: 11/19/2022] Open
Abstract
Following an extensive review of the literature, we further analyze the published data to examine the health effects of indoor exposure to particulate matter (PM) of outdoor origin. We obtained data on all-cause, cardiovascular, and respiratory mortality per 10 μg/m3 increase in outdoor PM10 or PM2.5; the infiltration factors for buildings; and estimated time spent outdoors by individuals in the United States, Europe, China, and globally. These data were combined log-linear exposure–response model to estimate the all-cause, cardiovascular, and respiratory mortality of exposure to indoor PM pollution of outdoor origin. Indoor PM pollution of outdoor origin is a cause of considerable mortality, accounting for 81% to 89% of the total increase in mortality associated with exposure to outdoor PM pollution for the studied regions. The findings suggest that enhancing the capacity of buildings to protect occupants against exposure to outdoor PM pollution has significant potential to improve public health outcomes.
Collapse
Affiliation(s)
- Wenjing Ji
- Department of Building Science, School of Architecture, Tsinghua University, Beijing, 100084, China
| | - Bin Zhao
- Department of Building Science, School of Architecture, Tsinghua University, Beijing, 100084, China
- * E-mail:
| |
Collapse
|
96
|
Arku RE, Adamkiewicz G, Vallarino J, Spengler JD, Levy DE. Seasonal variability in environmental tobacco smoke exposure in public housing developments. INDOOR AIR 2015; 25:13-20. [PMID: 24750252 PMCID: PMC4201978 DOI: 10.1111/ina.12121] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/29/2014] [Accepted: 04/10/2014] [Indexed: 05/13/2023]
Abstract
The risk of tobacco smoking and second-hand smoke (SHS) exposure combined are the leading contributors to disease burden in high-income countries. Recent studies and policies are focusing on reducing exposure to SHS in multiunit housing (MUH), especially public housing. We examined seasonal patterns of SHS levels within indoor common areas located on Boston Housing Authority (BHA) properties. We measured weekly integrated and continuous fine particulate matter (PM2.5) and passive airborne nicotine in six buildings of varying building and occupant characteristics in summer 2012 and winter 2013. The average weekly indoor PM2.5 concentration across all six developments was 9.2 μg/m3, higher during winter monitoring period (10.3 μg/m3) compared with summer (8.0 μg/m3). Airborne nicotine concentrations ranged from no detection to about 5000 ng/m3 (mean 311 ng/m3). Nicotine levels were significantly higher in the winter compared with summer (620 vs. 85 ng/m3; 95% CI: 72-998). Smoking-related exposures within Boston public housing vary by season, building types, and resident smoking policy. Our results represent exposure disparities that may contribute to health disparities in low-income communities and highlight the potential importance of efforts to mitigate SHS exposures during winter when outdoor-indoor exchange rates are low and smokers may tend to stay indoors. Our findings support the use of smoke-free policy as an effective tool to eliminate SHS exposure and protect non-smokers, especially residents of MUH.
Collapse
Affiliation(s)
- Raphael E Arku
- Department of Environmental Health, Harvard School of Public Health, Boston, USA
| | - Gary Adamkiewicz
- Department of Environmental Health, Harvard School of Public Health, Boston, USA
| | - Jose Vallarino
- Department of Environmental Health, Harvard School of Public Health, Boston, USA
| | - John D Spengler
- Department of Environmental Health, Harvard School of Public Health, Boston, USA
| | - Douglas E Levy
- Mongan Institute for Health Policy, Massachusetts General Hospital, Boston, USA
- Department of Medicine, Harvard Medical School, Boston, USA
| |
Collapse
|
97
|
Taylor J, Shrubsole C, Davies M, Biddulph P, Das P, Hamilton I, Vardoulakis S, Mavrogianni A, Jones B, Oikonomou E. The modifying effect of the building envelope on population exposure to PM2.5 from outdoor sources. INDOOR AIR 2014; 24:639-51. [PMID: 24713025 PMCID: PMC4278446 DOI: 10.1111/ina.12116] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/17/2013] [Accepted: 04/03/2014] [Indexed: 05/12/2023]
Abstract
UNLABELLED A number of studies have estimated population exposure to PM2.5 by examining modeled or measured outdoor PM2.5 levels. However, few have taken into account the mediating effects of building characteristics on the ingress of PM2.5 from outdoor sources and its impact on population exposure in the indoor domestic environment. This study describes how building simulation can be used to determine the indoor concentration of outdoor-sourced pollution for different housing typologies and how the results can be mapped using building stock models and Geographical Information Systems software to demonstrate the modifying effect of dwellings on occupant exposure to PM2.5 across London. Building archetypes broadly representative of those in the Greater London Authority were simulated for pollution infiltration using EnergyPlus. In addition, the influence of occupant behavior on indoor levels of PM2.5 from outdoor sources was examined using a temperature-dependent window-opening scenario. Results demonstrate a range of I/O ratios of PM2.5 , with detached and semi-detached dwellings most vulnerable to high levels of infiltration. When the results are mapped, central London shows lower I/O ratios of PM2.5 compared with outer London, an apparent inversion of exposure most likely caused by the prevalence of flats rather than detached or semi-detached properties. PRACTICAL IMPLICATIONS Population exposure to air pollution is typically evaluated using the outdoor concentration of pollutants and does not account for the fact that people in London spend over 80% of their time indoors. In this article, building simulation is used to model the infiltration of outdoor PM2.5 into the domestic indoor environment for dwellings in a London building stock model, and the results mapped. The results show the variation in relative vulnerability of dwellings to pollution infiltration, as well as an estimated absolute indoor concentration across the Greater London Authority (GLA) scaled by local outdoor levels. The practical application of this work is a better understanding of the modifying effect of the building geometry and envelope design on pollution exposure, and how the London building stock may alter exposure. The results will be used to inform population exposure to PM2.5 in future environmental epidemiological studies.
Collapse
Affiliation(s)
- J Taylor
- Bartlett School of Graduate Studies, UCLLondon, UK
- J. Taylor, Bartlett School of Graduate Studies, UCL Central House 14 Upper Woburn Place, London WC1H 0NN, UK, Tel.: +44 (0)20 7679 2000, Fax: +44 (0)20 7679 7453, e-mail:
| | - C Shrubsole
- Bartlett School of Graduate Studies, UCLLondon, UK
| | - M Davies
- Bartlett School of Graduate Studies, UCLLondon, UK
| | - P Biddulph
- UCL Energy Institute, The Bartlett, UCLLondon, UK
| | - P Das
- Bartlett School of Graduate Studies, UCLLondon, UK
| | - I Hamilton
- UCL Energy Institute, The Bartlett, UCLLondon, UK
| | - S Vardoulakis
- Centre for Radiation, Chemical and Environmental Hazards, Public Health EnglandOxfordshire, UK
| | | | - B Jones
- Department of Architecture and Built Environment, University of NottinghamNottingham, UK
| | - E Oikonomou
- UCL Energy Institute, The Bartlett, UCLLondon, UK
| |
Collapse
|
98
|
Reche C, Viana M, Rivas I, Bouso L, Àlvarez-Pedrerol M, Alastuey A, Sunyer J, Querol X. Outdoor and indoor UFP in primary schools across Barcelona. THE SCIENCE OF THE TOTAL ENVIRONMENT 2014; 493:943-953. [PMID: 25003584 DOI: 10.1016/j.scitotenv.2014.06.072] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/25/2014] [Revised: 06/05/2014] [Accepted: 06/18/2014] [Indexed: 06/03/2023]
Abstract
Indoor and outdoor measurements of real-time ultrafine particles (UFP; N10-700 in this study) number concentration and average diameter were collected twice at 39 primary schools located in Barcelona (Spain), with classrooms naturally ventilated under warm weather conditions. Simultaneous outdoor N concentration measurements at schools under different traffic exposures showed the important role of this source, with higher levels by 40% on average at schools near heavy traffic, highlighting thus the increased exposure of children due to urban planning decisions. A well-defined spatial pattern of outdoor UFP levels was observed. Midday increases in outdoor N levels mainly attributed to nucleation processes have been recorded both at high and low temperatures in several of the outdoor school sites (increasing levels by 15%-70%). The variation of these increases also followed a characteristic spatial pattern, pointing at schools' location as a key variable in terms of UFP load owing to the important contribution of traffic emissions. Indoor N concentrations were to some extent explained by outdoor N concentrations during school hours, together with average temperatures, related with natural ventilation. Outdoor midday increases were generally mimicked by indoor N concentrations, especially under warm temperatures. At specific cases, indoor concentrations during midday were 30%-40% higher than outdoor. The time scale of these observations evidenced the possible role of: a) secondary particle formation enhanced by indoor precursors or conditions, maybe related with surface chemistry reactions mediated by O3, and/or b) UFP from cooking activities. Significant indoor N increases were detected after school hours, probably associated with cleaning activities, resulting in indoor N concentrations up to 3 times higher than those in outdoor. A wide variability of indoor/outdoor ratios of N concentrations and mean UFP sizes was detected among schools and measurement periods, which seems to be partly associated with climatic conditions and O3 levels, although further research is required.
Collapse
Affiliation(s)
- C Reche
- Institute for Environmental Assessment and Water Research (IDÆA-CSIC), Barcelona, Spain.
| | - M Viana
- Institute for Environmental Assessment and Water Research (IDÆA-CSIC), Barcelona, Spain
| | - I Rivas
- Institute for Environmental Assessment and Water Research (IDÆA-CSIC), Barcelona, Spain; Centre for Research in Environmental Epidemiology (CREAL), Barcelona, Spain; Universitat Pompeu Fabra (UPF), Barcelona, Spain; CIBER Epidemiología y Salud Pública (CIBERESP), Spain; Institut de Ciencia i Tecnologia Ambientals, Universitat Autonoma de Barcelona (UAB), Bellaterra, Cerdanyola, Spain
| | - L Bouso
- Centre for Research in Environmental Epidemiology (CREAL), Barcelona, Spain; Universitat Pompeu Fabra (UPF), Barcelona, Spain; CIBER Epidemiología y Salud Pública (CIBERESP), Spain
| | - M Àlvarez-Pedrerol
- Centre for Research in Environmental Epidemiology (CREAL), Barcelona, Spain; Universitat Pompeu Fabra (UPF), Barcelona, Spain; CIBER Epidemiología y Salud Pública (CIBERESP), Spain
| | - A Alastuey
- Institute for Environmental Assessment and Water Research (IDÆA-CSIC), Barcelona, Spain
| | - J Sunyer
- Centre for Research in Environmental Epidemiology (CREAL), Barcelona, Spain; Hospital del Mar Research Institute (IMIM), Barcelona, Spain; Universitat Pompeu Fabra (UPF), Barcelona, Spain; CIBER Epidemiología y Salud Pública (CIBERESP), Spain
| | - X Querol
- Institute for Environmental Assessment and Water Research (IDÆA-CSIC), Barcelona, Spain
| |
Collapse
|
99
|
Lee WC, Wolfson JM, Catalano PJ, Rudnick SN, Koutrakis P. Size-resolved deposition rates for ultrafine and submicrometer particles in a residential housing unit. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2014; 48:10282-10290. [PMID: 25126897 DOI: 10.1021/es502278k] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
We estimated the size-resolved particle deposition rates for the ultrafine and submicrometer particles using a nonlinear regression method with unknown particle background concentrations during nonsourced period following a controlled sourced period in a well-mixed residential environment. A dynamic adjustment method in conjunction with the constant injection of tracer gas was used to maintain the air exchange rate at three target levels across the range of 0.61-1.24 air change per hour (ACH). Particle deposition was found to be highly size dependent with rates ranging from 0.68 ± 0.10 to 5.03 ± 0.20 h(-1) (mean ± s.e.). Our findings also suggest that the effect of air exchange on the particle deposition under enhanced air mixing was relatively small when compared to both the strong influence of size-dependent deposition mechanisms and the effects of mechanical air mixing by fans. Nonetheless, the significant association between air exchange and particle deposition rates for a few size categories indicated potential influence of air exchange on particle deposition. In the future, the proposed approach can be used to explore the separate or composite effects between air exchange and air mixing on particle deposition rates, which will contribute to improved assessment of human exposure to ultrafine and submicrometer particles.
Collapse
Affiliation(s)
- Wan-Chen Lee
- Department of Environmental Health, Harvard School of Public Health , 401 Park Drive, Landmark Center West, Boston, Massachusetts 02215, United States
| | | | | | | | | |
Collapse
|
100
|
Hasheminassab S, Daher N, Shafer MM, Schauer JJ, Delfino RJ, Sioutas C. Chemical characterization and source apportionment of indoor and outdoor fine particulate matter (PM(2.5)) in retirement communities of the Los Angeles Basin. THE SCIENCE OF THE TOTAL ENVIRONMENT 2014; 490:528-37. [PMID: 24880542 PMCID: PMC4098872 DOI: 10.1016/j.scitotenv.2014.05.044] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2014] [Revised: 05/03/2014] [Accepted: 05/13/2014] [Indexed: 04/15/2023]
Abstract
Concurrent indoor and outdoor measurements of fine particulate matter (PM2.5) were conducted at three retirement homes in the Los Angeles Basin during two separate phases (cold and warm) between 2005 and 2006. Indoor-to-outdoor relationships of PM2.5 chemical constituents were determined and sources of indoor and outdoor PM2.5 were evaluated using a molecular marker-based chemical mass balance (MM-CMB) model. Indoor levels of elemental carbon (EC) along with metals and trace elements were found to be significantly affected by outdoor sources. EC, in particular, displayed very high indoor-to-outdoor (I/O) mass ratios accompanied by strong I/O correlations, illustrating the significant impact of outdoor sources on indoor levels of EC. Similarly, indoor levels of polycyclic aromatic hydrocarbons (PAHs), hopanes, and steranes were strongly correlated with their outdoor components and displayed I/O ratios close to unity. On the other hand, concentrations of n-alkanes and organic acids inside the retirement communities were dominated by indoor sources (e.g. food cooking and consumer products), as indicated by their I/O ratios, which exceeded unity. Source apportionment results revealed that vehicular emissions were the major contributor to both indoor and outdoor PM2.5, accounting for 39 and 46% of total mass, respectively. Moreover, the contribution of vehicular sources to indoor levels was generally comparable to its corresponding outdoor estimate. Other water-insoluble organic matter (other WIOM), which accounts for emissions from uncharacterized primary biogenic sources, displayed a wider range of contributions, varying from 2 to 73% of PM2.5, across all sites and phases of the study. Lastly, higher indoor than outdoor contribution of other water-soluble organic matter (other WSOM) was evident at some of the sites, suggesting the production of secondary aerosols as well as direct emissions from primary sources (including cleaning or other consumer products) at the indoor environments.
Collapse
Affiliation(s)
- Sina Hasheminassab
- University of Southern California, Department of Civil and Environmental Engineering, Los Angeles, CA, USA
| | - Nancy Daher
- University of Southern California, Department of Civil and Environmental Engineering, Los Angeles, CA, USA
| | - Martin M Shafer
- University of Wisconsin-Madison, Environmental Chemistry and Technology Program, Madison, WI, USA
| | - James J Schauer
- University of Wisconsin-Madison, Environmental Chemistry and Technology Program, Madison, WI, USA
| | - Ralph J Delfino
- University of California, Department of Epidemiology, School of Medicine, 224 Irvine Hall, Irvine, CA, USA
| | - Constantinos Sioutas
- University of Southern California, Department of Civil and Environmental Engineering, Los Angeles, CA, USA.
| |
Collapse
|