1
|
Sakthivelpathi V, Li T, Qian Z, Lee C, Taylor Z, Chung JH. Advancements and Applications of Micro and Nanostructured Capacitive Sensors: A Review. SENSORS AND ACTUATORS. A, PHYSICAL 2024; 377:115701. [PMID: 39129941 PMCID: PMC11308742 DOI: 10.1016/j.sna.2024.115701] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/13/2024]
Abstract
Capacitors are essential components in modern electrical systems, functioning primarily to store electrical charges and regulate current flow. Capacitive sensors, developed in the 20th century, have become crucial in various applications, including touchscreens and smart devices, due to their ability to detect both metallic and non-metallic objects with high sensitivity and low energy consumption. The advancement of microelectromechanical systems (MEMS) and nanotechnology has significantly enhanced the capabilities of capacitive sensors, leading to unprecedented sensitivity, dynamic range, and cost-effectiveness. These sensors are integral to modern devices, enabling precise measurements of proximity, pressure, strain, and other parameters. This review provides a comprehensive overview of the development, fabrication, and integration of micro and nanostructured capacitive sensors. In terms of an electric field, the working and detection principles are discussed with analytical equations and our numerical results. The focus extends to novel fabrication methods using advanced materials to enhance sensitivities for various parameters, such as proximity, force, pressure, strain, temperature, humidity, and liquid sensing. Their applications are demonstrated in wearable devices, human-machine interfaces, biomedical sensing, health monitoring, robotics control, industrial monitoring, and molecular detection. By consolidating existing research, this review offers insights into the advancements and future directions of capacitive sensor technology.
Collapse
Affiliation(s)
| | - Tianyi Li
- Mechanical Engineering, University of Washington, Seattle, WA, USA 98195
| | - Zhongjie Qian
- Mechanical Engineering, University of Washington, Seattle, WA, USA 98195
| | - Changwoo Lee
- Mechanical Engineering, University of Washington, Seattle, WA, USA 98195
| | - Zachary Taylor
- Mechanical Engineering, University of Washington, Seattle, WA, USA 98195
| | - Jae-Hyun Chung
- Mechanical Engineering, University of Washington, Seattle, WA, USA 98195
| |
Collapse
|
2
|
Assaifan AK. Thiol-SAM Concentration Effect on the Performance of Interdigitated Electrode-Based Redox-Free Biosensors. MICROMACHINES 2024; 15:1254. [PMID: 39459128 PMCID: PMC11509288 DOI: 10.3390/mi15101254] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/18/2024] [Revised: 10/07/2024] [Accepted: 10/11/2024] [Indexed: 10/28/2024]
Abstract
Despite the direct, redox-free and simple detection non-faradaic impedimetric biosensors offer, considerable optimizations are required to enhance their performance for the detection of various biomarkers. Non-faradaic EIS sensors' performance depends on the interfacial capacitance between a polarized biosensor surface and the tested sample solution. Careful engineering and design of the interfacial capacitance is encouraged to magnify the redout signal upon bioreceptor-antigen interactions. One of the methods to achieve this goal is by optimizing the self-assembled monolayer concentration, which has not been reported for non-faradaic impedimetric sensors. Here, the impact of alkanethiolate (cysteamine) concentration on the performance of gold (Au) interdigitated electrode (Au-IDE) biosensors is reported. Six sets of biosensors were prepared, each with a different cysteamine concentration: 100 nM, 1 μM, 10 μM, 100 μM, 1 mM, and 10 mM. The biosensors were prepared for the direct detection of LDL cholesterol by attaching LDL antibodies on top of the cysteamine via a glutaraldehyde cross-linker. As the concentration of cysteamine increased from 100 nM to 100 μM, the sensitivity of the biosensor increased from 6.7 to 16.2 nF/ln (ng/mL). As the cysteamine concentration increased from 100 μM to 10 mM, the sensitivity deteriorated. The limit of detection (LoD) of the biosensor improved as the cysteamine increased from 100 nM to 100 μM (i.e., 400 ng/mL to 59 pg/mL). However, the LoD started to increase to 67 pg/mL and 16 ng/mL for 1 mM and 10 mM cysteamine concentrations, respectively. This shows that the cysteamine concentration has a detrimental effect on redox-free biosensors. The cysteamine layer has to be as thin as possible and uniformly cover the electrode surfaces to maximize positive readout signals and reduce negative signals, significantly improving both sensitivity and LoD.
Collapse
Affiliation(s)
- Abdulaziz K. Assaifan
- Department of Biomedical Technology, College of Applied Medical Sciences, King Saud University, P.O. Box 10219, Riyadh 11433, Saudi Arabia;
- Biological and Environmental Sensing Research Unit, King Abdullah Institute for Nanotechnology, King Saud University, P.O. Box 2455, Riyadh 11451, Saudi Arabia
| |
Collapse
|
3
|
Tsai PC, Chen RLC, Hsieh BC, Cheng TJ. Nitrocellulose/acrylic resin coated screen-printed carbon electrode to construct a capacitive immunosensor for anti-BSA. Biosens Bioelectron 2024; 258:116376. [PMID: 38739999 DOI: 10.1016/j.bios.2024.116376] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2024] [Revised: 05/01/2024] [Accepted: 05/08/2024] [Indexed: 05/16/2024]
Abstract
The capacitive immunosensor, known for its label-free simplicity, has great potential for point-of-care diagnostics. However, the interaction between insulation and recognition layers on the sensing electrode greatly affects its performance. This study introduces a pioneering dual-layer strategy, implementing a novel combination of acrylic resin (AR) and nitrocellulose (NC) coatings on screen-printed carbon electrodes (SPCEs). This innovative approach not only enhances the dielectric properties of the capacitive sensor but also streamlines the immobilization of recognizing elements. Particularly noteworthy is the superior reliability and insulation offered by the AR coating, surpassing the limitations of traditional self-assembled monolayer (SAM) modifications. This dual-layer methodology establishes a robust foundation for constructing capacitive sensors optimized specifically for liquid medium-based biosensing applications. The NC coating in this study represents a breakthrough in effectively immobilizing BSA, unraveling the capacitive response intricately linked to the quantity of adsorbed recognizing elements. The results underscore the prowess of the proposed immunosensor, showcasing a meticulously defined linear calibration curve for anti-BSA (ranging from 0 to 25 μg/ml). Additionally, specific interactions with anti-HAS and anti-TNF-α further validate the versatility and efficacy of the developed immunosensor. This work presents a streamlined and highly efficient protocol for developing label-free immunosensors for antibody determination and introduces a paradigm shift by utilizing readily available electrodes and sensing systems. The findings are poised to catalyze a significant acceleration in the advancement of biosensor technology, opening new avenues for innovative applications in point-of-care diagnostics.
Collapse
Affiliation(s)
- Pei-Chia Tsai
- Department of Biomechatronics Engineering, College of Bio-Resources and Agriculture, National Taiwan University, Taipei, Taiwan
| | - Richie L C Chen
- Department of Biomechatronics Engineering, College of Bio-Resources and Agriculture, National Taiwan University, Taipei, Taiwan
| | - Bo-Chuan Hsieh
- Department of Biomechatronics Engineering, College of Bio-Resources and Agriculture, National Taiwan University, Taipei, Taiwan
| | - Tzong-Jih Cheng
- Department of Biomechatronics Engineering, College of Bio-Resources and Agriculture, National Taiwan University, Taipei, Taiwan.
| |
Collapse
|
4
|
Huang L, Zhang C, Ye R, Yan B, Zhou X, Xu W, Guo J. Capacitive biosensors for label-free and ultrasensitive detection of biomarkers. Talanta 2024; 266:124951. [PMID: 37487266 DOI: 10.1016/j.talanta.2023.124951] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Revised: 07/10/2023] [Accepted: 07/14/2023] [Indexed: 07/26/2023]
Abstract
Capacitive biosensors are label-free capacitors that can detect biomarkers with the outstanding advantages of simplicity, low cost, and ultrahigh sensitivity. A typical capacitive biosensor consists of a bioreceptor and a transducer, where the bioreceptor captures the biomarker to form a bioreceptor/biomarker conjugate and the transducer generates a detectable signal. In general, antibodies, aptamers, or proteins are exploited as the bioreceptor, while various electrodes including carbon electrodes (CEs), gold electrodes (AuEs), or interdigitated electrodes (IDEs) may serve as the transducer. Because the formation of bioreceptor/biomarker conjugates often leads to a change in capacitance, the capacitive signal is then employed for biomarker detection. This review summarizes recent advances in capacitive biosensors for the detection of biomarkers over the last five years. With a focus on the three common types of bioreceptors, i.e., antibodies, aptamers, and proteins, capacitive biosensors using CEs, AuEs, and IDEs as the transducers are discussed in detail. The immobilization of bioreceptors and signal amplification strategies are described to provide a robust overview of capacitive biosensors for biomarker detection. In addition, analytical methods and future prospects are given to support the application of capacitive biosensors.
Collapse
Affiliation(s)
- Lei Huang
- Yangtze Delta Region Institute (Huzhou), University of Electronic Science and Technology of China, Huzhou, China; School of Resources and Environment, University of Electronic Science and Technology of China, Chengdu, China
| | - Cheng Zhang
- Yangtze Delta Region Institute (Huzhou), University of Electronic Science and Technology of China, Huzhou, China
| | - Run Ye
- Yangtze Delta Region Institute (Huzhou), University of Electronic Science and Technology of China, Huzhou, China
| | - Bin Yan
- Yangtze Delta Region Institute (Huzhou), University of Electronic Science and Technology of China, Huzhou, China.
| | - Xiaojia Zhou
- Yangtze Delta Region Institute (Huzhou), University of Electronic Science and Technology of China, Huzhou, China.
| | - Wenbo Xu
- School of Resources and Environment, University of Electronic Science and Technology of China, Chengdu, China
| | - Jinhong Guo
- School of Sensing Science and Engineering, Shanghai Jiao Tong University, Shanghai, China.
| |
Collapse
|
5
|
Robinson C, Juska VB, O'Riordan A. Surface chemistry applications and development of immunosensors using electrochemical impedance spectroscopy: A comprehensive review. ENVIRONMENTAL RESEARCH 2023; 237:116877. [PMID: 37579966 DOI: 10.1016/j.envres.2023.116877] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Revised: 08/04/2023] [Accepted: 08/10/2023] [Indexed: 08/16/2023]
Abstract
Immunosensors are promising alternatives as detection platforms for the current gold standards methods. Electrochemical immunosensors have already proven their capability for the sensitive, selective, detection of target biomarkers specific to COVID-19, varying cancers or Alzheimer's disease, etc. Among the electrochemical techniques, electrochemical impedance spectroscopy (EIS) is a highly sensitive technique which examines the impedance of an electrochemical cell over a range of frequencies. There are several important critical requirements for the construction of successful impedimetric immunosensor. The applied surface chemistry and immobilisation protocol have impact on the electroanalytical performance of the developed immunosensors. In this Review, we summarise the building blocks of immunosensors based on EIS, including self-assembly monolayers, nanomaterials, polymers, immobilisation protocols and antibody orientation.
Collapse
Affiliation(s)
- Caoimhe Robinson
- Tyndall National Institute, University College Cork, T12 R5CP, Cork, Ireland
| | - Vuslat B Juska
- Tyndall National Institute, University College Cork, T12 R5CP, Cork, Ireland.
| | - Alan O'Riordan
- Tyndall National Institute, University College Cork, T12 R5CP, Cork, Ireland.
| |
Collapse
|
6
|
Calabrese A, Capo A, Capaccio A, Agovino E, Varriale A, Pascale M, D'Auria S, Staiano M. An Impedance-Based Immunosensor for the Detection of Ovalbumin in White Wine. BIOSENSORS 2023; 13:669. [PMID: 37504068 PMCID: PMC10377481 DOI: 10.3390/bios13070669] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/18/2023] [Revised: 06/17/2023] [Accepted: 06/20/2023] [Indexed: 07/29/2023]
Abstract
Food allergies are an exceptional response of the immune system caused by the ingestion of specific foods. The main foods responsible for allergic reactions are milk, eggs, seafood, soy, peanuts, tree nuts, wheat, and their derived products. Chicken egg ovalbumin (OVA), a common allergen molecule, is often used for the clarification process of wine. Traces of OVA remain in the wine during the fining process, and they can cause significant allergic reactions in sensitive consumers. Consequently, the European Food Safety Authority (EFSA) and the American Food and Drug Administration (FDA) have shown the risks for allergic people to assume allergenic foods and food ingredients, including eggs. Commonly, OVA detection requires sophisticated and time-consuming analytical techniques. Intending to develop a faster assay, we designed a proof-of-concept non-Faradaic impedimetric immunosensor for monitoring the presence of OVA in wine. Polyclonal antibodies anti-OVA were covalently immobilised onto an 11-mercaptoundecanoic-acid (11-MUA)-modified gold surface. The developed immunosensor was able to detect OVA in diluted white wine without the need for an external probe or any pre-treatment step with a sensitivity of 0.20 µg/mL, complying with the limit established by the resolution OIV/COMEX 502-2012 for the quantification of allergens in wine.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Sabato D'Auria
- Department of Biology, Agriculture and Food Science, CNR, Piazzale Aldo Moro, 7, 00185 Rome, Italy
| | - Maria Staiano
- Institute of Food Science, CNR, 83100 Avellino, Italy
| |
Collapse
|
7
|
Aptamer-functionalized capacitive biosensors. Biosens Bioelectron 2023; 224:115014. [PMID: 36628826 DOI: 10.1016/j.bios.2022.115014] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2022] [Revised: 11/17/2022] [Accepted: 12/13/2022] [Indexed: 12/25/2022]
Abstract
The growing use of aptamers as target recognition elements in label-free biosensing necessitates corresponding transducers that can be used in relevant environments. While popular in many fields, capacitive sensors have seen relatively little, but growing use in conjunction with aptamers for sensing diverse targets. Few reports have shown physiologically relevant sensitivity in laboratory conditions and a cohesive picture on how target capture modifies the measured capacitance has been lacking. In this review, we assess the current state of the field in three areas: small molecule, protein, and cell sensing. We critically analyze the proposed hypotheses on how aptamer-target capture modifies the capacitance, as many mechanistic postulations appear to conflict between published works. As the field matures, we encourage future works to investigate individual aptamer-target interactions and to interrogate the physical mechanisms leading to measured changes in capacitance. To this point, we provide recommendations on best practices for developing aptasensors with a particular focus on considerations for biosensing in clinical settings.
Collapse
|
8
|
Ismail SNA, Nayan NA, Mohammad Haniff MAS, Jaafar R, May Z. Wearable Two-Dimensional Nanomaterial-Based Flexible Sensors for Blood Pressure Monitoring: A Review. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:852. [PMID: 36903730 PMCID: PMC10005058 DOI: 10.3390/nano13050852] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/02/2023] [Revised: 02/20/2023] [Accepted: 02/21/2023] [Indexed: 06/18/2023]
Abstract
Flexible sensors have been extensively employed in wearable technologies for physiological monitoring given the technological advancement in recent years. Conventional sensors made of silicon or glass substrates may be limited by their rigid structures, bulkiness, and incapability for continuous monitoring of vital signs, such as blood pressure (BP). Two-dimensional (2D) nanomaterials have received considerable attention in the fabrication of flexible sensors due to their large surface-area-to-volume ratio, high electrical conductivity, cost effectiveness, flexibility, and light weight. This review discusses the transduction mechanisms, namely, piezoelectric, capacitive, piezoresistive, and triboelectric, of flexible sensors. Several 2D nanomaterials used as sensing elements for flexible BP sensors are reviewed in terms of their mechanisms, materials, and sensing performance. Previous works on wearable BP sensors are presented, including epidermal patches, electronic tattoos, and commercialized BP patches. Finally, the challenges and future outlook of this emerging technology are addressed for non-invasive and continuous BP monitoring.
Collapse
Affiliation(s)
- Siti Nor Ashikin Ismail
- Department of Electrical, Electronic and Systems Engineering, Universiti Kebangsaan Malaysia, Bangi 43600 UKM, Selangor, Malaysia
| | - Nazrul Anuar Nayan
- Department of Electrical, Electronic and Systems Engineering, Universiti Kebangsaan Malaysia, Bangi 43600 UKM, Selangor, Malaysia
- Institute Islam Hadhari, Universiti Kebangsaan Malaysia, Bangi 43600 UKM, Selangor, Malaysia
| | | | - Rosmina Jaafar
- Department of Electrical, Electronic and Systems Engineering, Universiti Kebangsaan Malaysia, Bangi 43600 UKM, Selangor, Malaysia
| | - Zazilah May
- Electrical and Electronic Engineering Department, Universiti Teknologi Petronas, Seri Iskandar 32610, Perak, Malaysia
| |
Collapse
|
9
|
Sandoval Bojórquez D, Janićijević Ž, Palestina Romero B, Oliveros Mata ES, Laube M, Feldmann A, Kegler A, Drewitz L, Fowley C, Pietzsch J, Fassbender J, Tonn T, Bachmann M, Baraban L. Impedimetric Nanobiosensor for the Detection of SARS-CoV-2 Antigens and Antibodies. ACS Sens 2023; 8:576-586. [PMID: 36763494 PMCID: PMC9940615 DOI: 10.1021/acssensors.2c01686] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2022] [Accepted: 01/24/2023] [Indexed: 02/11/2023]
Abstract
Detection of antigens and antibodies (Abs) is of great importance in determining the infection and immunity status of the population, as they are key parameters guiding the handling of pandemics. Current point-of-care (POC) devices are a convenient option for rapid screening; however, their sensitivity requires further improvement. We present an interdigitated gold nanowire-based impedance nanobiosensor to detect COVID-19-associated antigens (receptor-binding domain of S1 protein of the SARS-CoV-2 virus) and respective Abs appearing during and after infection. The electrochemical impedance spectroscopy technique was used to assess the changes in measured impedance resulting from the binding of respective analytes to the surface of the chip. After 20 min of incubation, the sensor devices demonstrate a high sensitivity of about 57 pS·sn per concentration decade and a limit of detection (LOD) of 0.99 pg/mL for anti-SARS-CoV-2 Abs and a sensitivity of around 21 pS·sn per concentration decade and an LOD of 0.14 pg/mL for the virus antigen detection. Finally, the analysis of clinical plasma samples demonstrates the applicability of the developed platform to assist clinicians and authorities in determining the infection or immunity status of the patients.
Collapse
Affiliation(s)
| | - Željko Janićijević
- Institute
of Radiopharmaceutical Cancer Research, Helmholtz-Zentrum Dresden-Rossendorf
e.V. (HZDR), 01328 Dresden, Germany
| | - Brenda Palestina Romero
- Institute
of Radiopharmaceutical Cancer Research, Helmholtz-Zentrum Dresden-Rossendorf
e.V. (HZDR), 01328 Dresden, Germany
| | - Eduardo Sergio Oliveros Mata
- Institute
of Ion Beam Physics and Materials Research, Helmholtz-Zentrum Dresden-Rossendorf
e.V. (HZDR), 01328 Dresden, Germany
| | - Markus Laube
- Institute
of Radiopharmaceutical Cancer Research, Helmholtz-Zentrum Dresden-Rossendorf
e.V. (HZDR), 01328 Dresden, Germany
| | - Anja Feldmann
- Institute
of Radiopharmaceutical Cancer Research, Helmholtz-Zentrum Dresden-Rossendorf
e.V. (HZDR), 01328 Dresden, Germany
| | - Alexandra Kegler
- Institute
of Radiopharmaceutical Cancer Research, Helmholtz-Zentrum Dresden-Rossendorf
e.V. (HZDR), 01328 Dresden, Germany
| | - Laura Drewitz
- Institute
of Radiopharmaceutical Cancer Research, Helmholtz-Zentrum Dresden-Rossendorf
e.V. (HZDR), 01328 Dresden, Germany
| | - Ciarán Fowley
- Institute
of Ion Beam Physics and Materials Research, Helmholtz-Zentrum Dresden-Rossendorf
e.V. (HZDR), 01328 Dresden, Germany
| | - Jens Pietzsch
- Institute
of Radiopharmaceutical Cancer Research, Helmholtz-Zentrum Dresden-Rossendorf
e.V. (HZDR), 01328 Dresden, Germany
- School
of Sciences, Faculty of Chemistry and Food Chemistry, Technische Universität Dresden, 01307 Dresden, Germany
| | - Juergen Fassbender
- Institute
of Ion Beam Physics and Materials Research, Helmholtz-Zentrum Dresden-Rossendorf
e.V. (HZDR), 01328 Dresden, Germany
| | - Torsten Tonn
- Transfusion
Medicine, Med. Faculty Carl-Gustav Carus, Technische Universität Dresden, 01307 Dresden, Germany
- Institute
for Transfusion Medicine Dresden, German
Red Cross Blood Donation Service North-East, 01307 Dresden, Germany
| | - Michael Bachmann
- Institute
of Radiopharmaceutical Cancer Research, Helmholtz-Zentrum Dresden-Rossendorf
e.V. (HZDR), 01328 Dresden, Germany
- Tumor
Immunology, University Cancer Center (UCC), University Hospital Carl
Gustav Carus Dresden, Technische Universität
Dresden, 01307 Dresden, Germany
- National
Center for Tumor Diseases (NCT), Dresden, Germany. Faculty of Medicine
and University Hospital Carl Gustav Carus, Technische Universität Dresden, 01307 Dresden, Germany
- German Cancer
Research Center (DKFZ), 69120 Heidelberg, Germany
- German
Cancer Consortium (DKTK), 01309 Dresden, Germany
| | - Larysa Baraban
- Institute
of Radiopharmaceutical Cancer Research, Helmholtz-Zentrum Dresden-Rossendorf
e.V. (HZDR), 01328 Dresden, Germany
| |
Collapse
|
10
|
Neshani S, Momeni K, Chen DJ, Neihart NM. Highly Sensitive Readout Interface for Real-Time Differential Precision Measurements with Impedance Biosensors. BIOSENSORS 2023; 13:77. [PMID: 36671912 PMCID: PMC9856043 DOI: 10.3390/bios13010077] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/15/2022] [Revised: 12/27/2022] [Accepted: 12/29/2022] [Indexed: 06/17/2023]
Abstract
Field deployment is critical to developing numerous sensitive impedance transducers. Precise, cost-effective, and real-time readout units are being sought to interface these sensitive impedance transducers for various clinical or environmental applications. This paper presents a general readout method with a detailed design procedure for interfacing impedance transducers that generate small fractional changes in the impedance characteristics after detection. The emphasis of the design is obtaining a target response resolution considering the accuracy in real-time. An entire readout unit with amplification/filtering and real-time data acquisition and processing using a single microcontroller is proposed. Most important design parameters, such as the signal-to-noise ratio (SNR), common-mode-to-differential conversion, digitization configuration/speed, and the data processing method are discussed here. The studied process can be used as a general guideline to design custom readout units to interface with various developed transducers in the laboratory and verify the performance for field deployment and commercialization. A single frequency readout unit with a target 8-bit resolution to interface differentially placed transducers (e.g., bridge configuration) is designed and implemented. A single MCU is programmed for real-time data acquisition and sine fitting. The 8-bit resolution is achieved even at low SNR levels of roughly 7 dB by setting the component values and fitting algorithm parameters with the given methods.
Collapse
Affiliation(s)
- Sara Neshani
- Electrical and Computer Engineering Department, University of Alabama, Tuscaloosa, AL 35401, USA
| | - Kasra Momeni
- Mechanical Engineering Department, University of Alabama, Tuscaloosa, AL 35401, USA
| | - Degang J. Chen
- Electrical Engineering Department, Iowa State University, Ames, IA 50010, USA
| | - Nathan M. Neihart
- Electrical Engineering Department, Iowa State University, Ames, IA 50010, USA
| |
Collapse
|
11
|
Piedimonte P, Sola L, Chiari M, Ferrari G, Sampietro M. Peptide-Based Sensor and Microfluidic Platform for IgG Antibody Detection by Differential Impedance Sensing. Methods Mol Biol 2023; 2578:191-198. [PMID: 36152288 DOI: 10.1007/978-1-0716-2732-7_13] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Serological assays enable infection screening as relatively easy-to-operate approaches compared with standard methods. In addition, to be relevant for early diagnosis, specific antibody detection is important for epidemiological surveillance and quantitative detection has potential significance for evaluating the severity and prognosis of different diseases.Here, we describe the detection process based on differential impedance sensing of IgG antibodies labeled with polystyrene nanoparticles. The electrode differential configuration, the amplification with nanoparticle functionalization, the electronic reading, and the microfluidic protocol allow to reach a limit of detection below 100 pg/mL for commercial IgG antibody spiked in buffer.
Collapse
Affiliation(s)
- Paola Piedimonte
- Department of Electronics Information and Bioengineering, Politecnico di Milano, Milan, Italy.
| | - Laura Sola
- National Research Council of Italy, Istituto di Scienze e Tecnologie Chimiche (SCITEC-CNR), Milan, Italy
| | - Marcella Chiari
- National Research Council of Italy, Istituto di Scienze e Tecnologie Chimiche (SCITEC-CNR), Milan, Italy
| | - Giorgio Ferrari
- Department of Electronics Information and Bioengineering, Politecnico di Milano, Milan, Italy
| | - Marco Sampietro
- Department of Electronics Information and Bioengineering, Politecnico di Milano, Milan, Italy
| |
Collapse
|
12
|
Shoute LCT, Abdelrasoul GN, Ma Y, Duarte PA, Edwards C, Zhuo R, Zeng J, Feng Y, Charlton CL, Kanji JN, Babiuk S, Chen J. Label-free impedimetric immunosensor for point-of-care detection of COVID-19 antibodies. MICROSYSTEMS & NANOENGINEERING 2023; 9:3. [PMID: 36597510 PMCID: PMC9805445 DOI: 10.1038/s41378-022-00460-5] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/15/2022] [Revised: 09/06/2022] [Accepted: 09/25/2022] [Indexed: 05/28/2023]
Abstract
The COVID-19 pandemic has posed enormous challenges for existing diagnostic tools to detect and monitor pathogens. Therefore, there is a need to develop point-of-care (POC) devices to perform fast, accurate, and accessible diagnostic methods to detect infections and monitor immune responses. Devices most amenable to miniaturization and suitable for POC applications are biosensors based on electrochemical detection. We have developed an impedimetric immunosensor based on an interdigitated microelectrode array (IMA) to detect and monitor SARS-CoV-2 antibodies in human serum. Conjugation chemistry was applied to functionalize and covalently immobilize the spike protein (S-protein) of SARS-CoV-2 on the surface of the IMA to serve as the recognition layer and specifically bind anti-spike antibodies. Antibodies bound to the S-proteins in the recognition layer result in an increase in capacitance and a consequent change in the impedance of the system. The impedimetric immunosensor is label-free and uses non-Faradaic impedance with low nonperturbing AC voltage for detection. The sensitivity of a capacitive immunosensor can be enhanced by simply tuning the ionic strength of the sample solution. The device exhibits an LOD of 0.4 BAU/ml, as determined from the standard curve using WHO IS for anti-SARS-CoV-2 immunoglobulins; this LOD is similar to the corresponding LODs reported for all validated and established commercial assays, which range from 0.41 to 4.81 BAU/ml. The proof-of-concept biosensor has been demonstrated to detect anti-spike antibodies in sera from patients infected with COVID-19 within 1 h. Photolithographically microfabricated interdigitated microelectrode array sensor chips & label-free impedimetric detection of COVID-19 antibody.
Collapse
Affiliation(s)
- Lian C. T. Shoute
- Department of Electrical and Computer Engineering, University of Alberta, Edmonton, AB T6G 2V4 Canada
| | - Gaser N. Abdelrasoul
- Department of Electrical and Computer Engineering, University of Alberta, Edmonton, AB T6G 2V4 Canada
| | - Yuhao Ma
- Department of Electrical and Computer Engineering, University of Alberta, Edmonton, AB T6G 2V4 Canada
| | - Pedro A. Duarte
- Department of Electrical and Computer Engineering, University of Alberta, Edmonton, AB T6G 2V4 Canada
| | - Cole Edwards
- Public Health Laboratory, Alberta Precision Laboratories, Edmonton, AB Canada
| | - Ran Zhuo
- Public Health Laboratory, Alberta Precision Laboratories, Edmonton, AB Canada
| | - Jie Zeng
- Department of Electrical and Computer Engineering, University of Alberta, Edmonton, AB T6G 2V4 Canada
| | - Yiwei Feng
- Department of Electrical and Computer Engineering, University of Alberta, Edmonton, AB T6G 2V4 Canada
| | - Carmen L. Charlton
- Public Health Laboratory, Alberta Precision Laboratories, Edmonton, AB Canada
- Department of Laboratory Medicine and Pathology, University of Alberta, Edmonton, AB T6G 2B7 Canada
- Li Ka Shing Institute for Virology, University of Alberta, Edmonton, AB Canada
| | - Jamil N. Kanji
- Public Health Laboratory, Alberta Precision Laboratories, Edmonton, AB Canada
- Department of Laboratory Medicine and Pathology, University of Alberta, Edmonton, AB T6G 2B7 Canada
- Division of Infectious Diseases, Department of Medicine, Cumming School of Medicine, University of Calgary, Calgary, AB Canada
- Department of Pathology & Laboratory Medicine, Cumming School of Medicine, University of Calgary, Calgary, AB Canada
| | - Shawn Babiuk
- National Centre for Foreign Animal Disease, Canadian Food Inspection Agency, Winnipeg, MB Canada
- Department of Immunology, University of Manitoba, Winnipeg, MB Canada
| | - Jie Chen
- Department of Electrical and Computer Engineering, University of Alberta, Edmonton, AB T6G 2V4 Canada
- Department of Biomedical Engineering, University of Alberta, Edmonton, AB T6G 2R3 Canada
| |
Collapse
|
13
|
Sampaio I, Takeuti NNK, Gusson B, Machado TR, Zucolotto V. Capacitive immunosensor for COVID-19 diagnosis. MICROELECTRONIC ENGINEERING 2023; 267:111912. [PMID: 36406866 PMCID: PMC9643278 DOI: 10.1016/j.mee.2022.111912] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Accepted: 11/05/2022] [Indexed: 06/16/2023]
Abstract
COVID-19 has spread worldwide and early detection has been the key to controlling its propagation and preventing severe cases. However, diagnostic devices must be developed using different strategies to avoid a shortage of supplies needed for tests' fabrication caused by their large demand in pandemic situations. Furthermore, some tropical and subtropical countries are also facing epidemics of Dengue and Zika, viruses with similar symptoms in early stages and cross-reactivity in serological tests. Herein, we reported a qualitative immunosensor based on capacitive detection of spike proteins of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the causative agent of COVID-19. The sensor device exhibited a good signal-to-noise ratio (SNR) at 1 kHz frequency, with an absolute value of capacitance variation significantly smaller for Dengue and Zika NS1 proteins (|ΔC| = 1.5 ± 1.0 nF and 1.8 ± 1.0 nF, respectively) than for the spike protein (|ΔC| = 7.0 ± 1.8 nF). Under the optimized conditions, the established biosensor is able to indicate that the sample contains target proteins when |ΔC| > 3.8 nF, as determined by the cut-off value (CO). This immunosensor was developed using interdigitated electrodes which require a measurement system with a simple electrical circuit that can be miniaturized to enable point-of-care detection, offering an alternative for COVID-19 diagnosis, especially in areas where there is also a co-incidence of Zika and Dengue.
Collapse
Affiliation(s)
- Isabella Sampaio
- GNano - Nanomedicine and Nanotoxicology Group, São Carlos Institute of Physics, University of São Paulo CP 369, 13560-970 São Carlos, SP, Brazil
| | - Nayla Naomi Kusimoto Takeuti
- GNano - Nanomedicine and Nanotoxicology Group, São Carlos Institute of Physics, University of São Paulo CP 369, 13560-970 São Carlos, SP, Brazil
| | - Beatriz Gusson
- GNano - Nanomedicine and Nanotoxicology Group, São Carlos Institute of Physics, University of São Paulo CP 369, 13560-970 São Carlos, SP, Brazil
| | - Thales Rafael Machado
- GNano - Nanomedicine and Nanotoxicology Group, São Carlos Institute of Physics, University of São Paulo CP 369, 13560-970 São Carlos, SP, Brazil
| | - Valtencir Zucolotto
- GNano - Nanomedicine and Nanotoxicology Group, São Carlos Institute of Physics, University of São Paulo CP 369, 13560-970 São Carlos, SP, Brazil
| |
Collapse
|
14
|
Robin P, Gerber-Lemaire S. Design and Preparation of Sensing Surfaces for Capacitive Biodetection. BIOSENSORS 2022; 13:17. [PMID: 36671852 PMCID: PMC9856139 DOI: 10.3390/bios13010017] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/23/2022] [Revised: 12/15/2022] [Accepted: 12/20/2022] [Indexed: 06/17/2023]
Abstract
Despite their high sensitivity and their suitability for miniaturization, biosensors are still limited for clinical applications due to the lack of reproducibility and specificity of their detection performance. The design and preparation of sensing surfaces are suspected to be a cause of these limitations. Here, we first present an updated overview of the current state of use of capacitive biosensors in a medical context. Then, we summarize the encountered strategies for the fabrication of capacitive biosensing surfaces. Finally, we describe the characteristics which govern the performance of the sensing surfaces, along with recent developments that were suggested to overcome their main current limitations.
Collapse
|
15
|
Mwanza D, Adeniyi O, Tesfalidet S, Nyokong T, Mashazi P. Capacitive label-free ultrasensitive detection of PSA on a covalently attached monoclonal anti-PSA antibody gold surface. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.116983] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
16
|
Hu W, Wu B, Srivastava SK, Ay SU. Comparative Study and Simulation of Capacitive Sensors in Microfluidic Channels for Sensitive Red Blood Cell Detection. MICROMACHINES 2022; 13:1654. [PMID: 36296007 PMCID: PMC9610494 DOI: 10.3390/mi13101654] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/26/2022] [Revised: 09/23/2022] [Accepted: 09/28/2022] [Indexed: 05/25/2023]
Abstract
Microfluidics provides an indispensable platform for combining analytical operations such as sample preparation, mixing, separation/enrichment, and detection onto a single compact platform, defined as a lab-on-a-chip (LOC) device with applicability in biomedical and life science applications. Due to its ease of integration, 1D interdigital capacitive (IDC) sensors have been used in microfluidic platforms to detect particles of interest. This paper presents a comparative study on the use of capacitive sensors for microfluidic devices to detect bioparticles, more specifically red blood cells (RBCs). The detection sensitivities of 1D, 2D, and 3D capacitive sensors were determined by simulation using COMSOL Multiphysics® v5.5. A water-filled 25 μm × 25 μm PDMS microfluidic channel was used with different sizes (5-10 μm) of red blood cells passing across the capacitive sensor regions. The conformal mapping was used for translating the 1D IDC sensor dimensions into equivalent 2D/3D parallel plate capacitance (PPC) sensor dimensions, creating similar absolute sensor capacitance. The detection sensitivity of each capacitive sensor is determined, and a new 3D PPC sensor structure was proposed to improve the sensitivity for high-resolution RBC detection in microfluidic channels. Proposed 2D and 3D sensors provide a 3× to 20× improvement in sensitivity compared to the standard 1D IDC structures, achieving a 100 aF capacitance difference when a healthy RBC passes in the structure.
Collapse
Affiliation(s)
- Wei Hu
- Thermo Fisher Scientific, Jinke Road 2537, Pudong District, Shanghai 201206, China
| | - Bingxing Wu
- Thermo Fisher Scientific, Jinke Road 2537, Pudong District, Shanghai 201206, China
| | - Soumya K. Srivastava
- Department of Chemical and Biomedical Engineering, West Virginia University, Morgantown, WV 26506-6102, USA
| | - Suat Utku Ay
- Department of Electrical and Computer Engineering, University of Idaho, Moscow, ID 83844-1023, USA
| |
Collapse
|
17
|
Mondal J, An JM, Surwase SS, Chakraborty K, Sutradhar SC, Hwang J, Lee J, Lee YK. Carbon Nanotube and Its Derived Nanomaterials Based High Performance Biosensing Platform. BIOSENSORS 2022; 12:731. [PMID: 36140116 PMCID: PMC9496036 DOI: 10.3390/bios12090731] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/30/2022] [Revised: 08/25/2022] [Accepted: 08/30/2022] [Indexed: 11/30/2022]
Abstract
After the COVID-19 pandemic, the development of an accurate diagnosis and monitoring of diseases became a more important issue. In order to fabricate high-performance and sensitive biosensors, many researchers and scientists have used many kinds of nanomaterials such as metal nanoparticles (NPs), metal oxide NPs, quantum dots (QDs), and carbon nanomaterials including graphene and carbon nanotubes (CNTs). Among them, CNTs have been considered important biosensing channel candidates due to their excellent physical properties such as high electrical conductivity, strong mechanical properties, plasmonic properties, and so on. Thus, in this review, CNT-based biosensing systems are introduced and various sensing approaches such as electrochemical, optical, and electrical methods are reported. Moreover, such biosensing platforms showed excellent sensitivity and high selectivity against not only viruses but also virus DNA structures. So, based on the amazing potential of CNTs-based biosensing systems, healthcare and public health can be significantly improved.
Collapse
Affiliation(s)
- Jagannath Mondal
- Department of Green Bio Engineering, Korea National University of Transportation, Chungju 27469, Korea
| | - Jeong Man An
- Department of Bioengineering, College of Engineering, Hanyang University, Seoul 04763, Korea
| | - Sachin S. Surwase
- 4D Convergence Technology Institute, Korea National University of Transportation, Jungpyeong 27909, Korea
| | - Kushal Chakraborty
- Department of IT and Energy Convergence (BK21 FOUR), Korea National University of Transportation, Chungju 27469, Korea
| | - Sabuj Chandra Sutradhar
- 4D Convergence Technology Institute, Korea National University of Transportation, Jungpyeong 27909, Korea
| | - Joon Hwang
- 4D Convergence Technology Institute, Korea National University of Transportation, Jungpyeong 27909, Korea
- Department of Aeronautical & Mechanical Design Engineering, Korea National University of Transportation, Chungju 27469, Korea
| | - Jaewook Lee
- 4D Convergence Technology Institute, Korea National University of Transportation, Jungpyeong 27909, Korea
| | - Yong-Kyu Lee
- Department of Green Bio Engineering, Korea National University of Transportation, Chungju 27469, Korea
- 4D Convergence Technology Institute, Korea National University of Transportation, Jungpyeong 27909, Korea
- Department of Chemical and Biological Engineering, Korea National University of Transportation, Chungju 27469, Korea
| |
Collapse
|
18
|
Mao S, Fu L, Yin C, Liu X, Karimi-Maleh H. The role of electrochemical biosensors in SARS-CoV-2 detection: a bibliometrics-based analysis and review. RSC Adv 2022; 12:22592-22607. [PMID: 36105989 PMCID: PMC9372877 DOI: 10.1039/d2ra04162f] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Accepted: 08/03/2022] [Indexed: 12/16/2022] Open
Abstract
The global pandemic of COVID-19, which began in late 2019, has resulted in extremely high morbidity and severe mortality worldwide, with important implications for human health, international trade, and national politics. Severe acute respiratory syndrome coronavirus (SARS-CoV-2) is the primary pathogen causing COVID-19. Analytical chemistry played an important role in this global epidemic event, and detection of SARS-CoV-2 even became a part of daily life. Analytical chemists have devoted much effort and enthusiasm to this event, and different analytical techniques have shown very rapid development. Electrochemical biosensors are highly efficient, sensitive, and cost-effective and have been used to detect many highly pathogenic viruses long before this event. However, another fact is that electrochemical biosensors are not the technology of choice for most detection applications. This review describes for the first time the role played by electrochemical biosensors in SARS-CoV-2 detection from a bibliometric perspective. This paper analyzed 254 relevant research papers up to June 2022. The contributions of different countries and institutions to this topic were analyzed. Keyword analysis was used to explore different methodological attempts of electrochemical detection techniques. More importantly, we are trying to find an answer to the question: do electrochemical biosensors have the potential to become a genuinely employable detection technology in an outbreak of infectious disease?
Collapse
Affiliation(s)
- Shudan Mao
- Key Laboratory of Pollution Exposure and Health Intervention of Zhejiang Province, Interdisciplinary Research Academy, Zhejiang Shuren University Hangzhou 310021 PR China
| | - Li Fu
- Key Laboratory of Novel Materials for Sensor of Zhejiang Province, College of Materials and Environmental Engineering, Hangzhou Dianzi University Hangzhou 310018 China
| | - Chengliang Yin
- National Engineering Laboratory for Medical Big Data Application Technology, Chinese PLA General Hospital Beijing China
- Medical Big Data Research Center, Medical Innovation Research Division of PLA General Hospital Beijing China
| | - Xiaozhu Liu
- Department of Cardiology, The Second Affiliated Hospital of Chongqing Medical University Chongqing 400010 China
| | - Hassan Karimi-Maleh
- School of Resources and Environment, University of Electronic Science and Technology of China Xiyuan Ave 611731 Chengdu China
- Department of Chemical Engineering, Quchan University of Technology Quchan 9477177870 Iran
- Department of Chemical Sciences, University of Johannesburg Doornfontein Campus, 2028 Johannesburg 17011 South Africa
| |
Collapse
|
19
|
Polat EO, Cetin MM, Tabak AF, Bilget Güven E, Uysal BÖ, Arsan T, Kabbani A, Hamed H, Gül SB. Transducer Technologies for Biosensors and Their Wearable Applications. BIOSENSORS 2022; 12:385. [PMID: 35735533 PMCID: PMC9221076 DOI: 10.3390/bios12060385] [Citation(s) in RCA: 35] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Revised: 05/16/2022] [Accepted: 05/27/2022] [Indexed: 05/17/2023]
Abstract
The development of new biosensor technologies and their active use as wearable devices have offered mobility and flexibility to conventional western medicine and personal fitness tracking. In the development of biosensors, transducers stand out as the main elements converting the signals sourced from a biological event into a detectable output. Combined with the suitable bio-receptors and the miniaturization of readout electronics, the functionality and design of the transducers play a key role in the construction of wearable devices for personal health control. Ever-growing research and industrial interest in new transducer technologies for point-of-care (POC) and wearable bio-detection have gained tremendous acceleration by the pandemic-induced digital health transformation. In this article, we provide a comprehensive review of transducers for biosensors and their wearable applications that empower users for the active tracking of biomarkers and personal health parameters.
Collapse
Affiliation(s)
- Emre Ozan Polat
- Faculty of Engineering and Natural Sciences, Kadir Has University, Cibali, Istanbul 34083, Turkey; (M.M.C.); (A.F.T.); (E.B.G.); (B.Ö.U.); (T.A.); (A.K.); (H.H.); (S.B.G.)
| | | | | | | | | | | | | | | | | |
Collapse
|
20
|
Yap SHK, Pan J, Linh DV, Zhang X, Wang X, Teo WZ, Zamburg E, Tham CK, Yew WS, Poh CL, Thean AVY. Engineered Nucleotide Chemicapacitive Microsensor Array Augmented with Physics-Guided Machine Learning for High-Throughput Screening of Cannabidiol. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2022; 18:e2107659. [PMID: 35521934 DOI: 10.1002/smll.202107659] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/09/2021] [Revised: 03/03/2022] [Indexed: 06/14/2023]
Abstract
The recent legalization of cannabidiol (CBD) to treat neurological conditions such as epilepsy has sparked rising interest across global pharmaceuticals and synthetic biology industries to engineer microbes for sustainable synthetic production of medicinal CBD. Since the process involves screening large amounts of samples, the main challenge is often associated with the conventional screening platform that is time consuming, and laborious with high operating costs. Here, a portable, high-throughput Aptamer-based BioSenSing System (ABS3 ) is introduced for label-free, low-cost, fully automated, and highly accurate CBD concentrations' classification in a complex biological environment. The ABS3 comprises an array of interdigitated microelectrode sensors, each functionalized with different engineered aptamers. To further empower the functionality of the ABS3 , unique electrochemical features from each sensor are synergized using physics-guided multidimensional analysis. The capabilities of this ABS3 are demonstrated by achieving excellent CBD concentrations' classification with a high prediction accuracy of 99.98% and a fast testing time of 22 µs per testing sample using the optimized random forest (RF) model. It is foreseen that this approach will be the key to the realistic transformation from fundamental research to system miniaturization for diagnostics of disease biomarkers and drug development in the field of chemical/bioanalytics.
Collapse
Affiliation(s)
- Stephanie Hui Kit Yap
- Department of Electrical and Computer Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore, 117583, Singapore
| | - Jieming Pan
- Department of Electrical and Computer Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore, 117583, Singapore
| | - Dao Viet Linh
- Department of Biomedical Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore, 117583, Singapore
- NUS Synthetic Biology for Clinical and Technological Innovation (SynCTI), National University of Singapore, 28 Medical Drive, Singapore, 117456, Singapore
| | - Xiangyu Zhang
- Department of Electrical and Computer Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore, 117583, Singapore
| | - Xinghua Wang
- Department of Electrical and Computer Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore, 117583, Singapore
| | - Wei Zhe Teo
- NUS Synthetic Biology for Clinical and Technological Innovation (SynCTI), National University of Singapore, 28 Medical Drive, Singapore, 117456, Singapore
- Department of Biochemistry, Yong Loo Lin School of Medicine, National University of Singapore, 8 Medical Drive, Singapore, 117597, Singapore
| | - Evgeny Zamburg
- Department of Electrical and Computer Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore, 117583, Singapore
| | - Chen-Khong Tham
- Department of Electrical and Computer Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore, 117583, Singapore
| | - Wen Shan Yew
- NUS Synthetic Biology for Clinical and Technological Innovation (SynCTI), National University of Singapore, 28 Medical Drive, Singapore, 117456, Singapore
- Department of Biochemistry, Yong Loo Lin School of Medicine, National University of Singapore, 8 Medical Drive, Singapore, 117597, Singapore
| | - Chueh Loo Poh
- Department of Biomedical Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore, 117583, Singapore
- NUS Synthetic Biology for Clinical and Technological Innovation (SynCTI), National University of Singapore, 28 Medical Drive, Singapore, 117456, Singapore
| | - Aaron Voon-Yew Thean
- Department of Electrical and Computer Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore, 117583, Singapore
| |
Collapse
|
21
|
Zhang Y, Liu Y. A Digital Microfluidic Device Integrated with Electrochemical Impedance Spectroscopy for Cell-Based Immunoassay. BIOSENSORS 2022; 12:330. [PMID: 35624631 PMCID: PMC9138827 DOI: 10.3390/bios12050330] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/19/2022] [Revised: 05/06/2022] [Accepted: 05/10/2022] [Indexed: 05/31/2023]
Abstract
The dynamic immune response to various diseases and therapies has been considered a promising indicator of disease status and therapeutic effectiveness. For instance, the human peripheral blood mononuclear cell (PBMC), as a major player in the immune system, is an important index to indicate a patient's immune function. Therefore, establishing a simple yet sensitive tool that can frequently assess the immune system during the course of disease and treatment is of great importance. This study introduced an integrated system that includes an electrochemical impedance spectroscope (EIS)-based biosensor in a digital microfluidic (DMF) device, to quantify the PBMC abundance with minimally trained hands. Moreover, we exploited the unique droplet manipulation feature of the DMF platform and conducted a dynamic cell capture assay, which enhanced the detection signal by 2.4-fold. This integrated system was able to detect as few as 104 PBMCs per mL, presenting suitable sensitivity to quantify PBMCs. This integrated system is easy-to-operate and sensitive, and therefore holds great potential as a powerful tool to profile immune-mediated therapeutic responses in a timely manner, which can be further evolved as a point-of-care diagnostic device to conduct near-patient tests from blood samples.
Collapse
Affiliation(s)
- Yuqian Zhang
- Department of Surgery, Division of Surgical Research, Mayo Clinic, Rochester, MN 55905, USA;
- Microbiome Program, Center for Individualized Medicine, Mayo Clinic, Rochester, MN 55905, USA
| | - Yuguang Liu
- Department of Surgery, Division of Surgical Research, Mayo Clinic, Rochester, MN 55905, USA;
- Microbiome Program, Center for Individualized Medicine, Mayo Clinic, Rochester, MN 55905, USA
- Department of Immunology, Mayo Clinic, Rochester, MN 55905, USA
| |
Collapse
|
22
|
Singh SK, Srinivasan A, Mitra S, Gooh Pattader PS. Carbon dots and Methylene blue facilitated photometric quantification of Hemoglobin. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2022; 271:120906. [PMID: 35077978 DOI: 10.1016/j.saa.2022.120906] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Revised: 01/08/2022] [Accepted: 01/13/2022] [Indexed: 06/14/2023]
Abstract
Early detection and monitoring of any abnormality of Hemoglobin (Hb) concentration in whole blood samples are important as this may be related to anemia, leukemia, dengue, etc. To facilitate quantitative detection and to monitor the hemoglobin level in the blood, we attempt to develop a low-cost, portable point of care (POC) device based on the spectrophotometric principle. Optical sensitivities of carbon quantum dots (CDs) are found to be highly responsive, while there is a selective reaction between Hb and reduced form of Methylene Blue (MBred). The interaction of Hb, MBred, and CDs is delineated using UV-Visible (UV-Vis) spectroscopy. CDs have a characteristic UV-Vis peak at ∼ 347 nm, and it shows a gradual increase in intensity with a slight red shift (∼355 nm) on the progressive increase in Hb concentration. Simultaneously, the colorless MBred is oxidized to its blue oxidized form MBox and its characteristic peak starts reappearing at ∼ 663 nm. These responses are exploited to quantify Hb concentration with a limit of detection (LOD) as low as ∼ 2 g dL-1 in a developed POC device, and the results are validated with the clinical data obtained from a local hospital with reasonably good agreement. This photometric detection approach can be adopted for other quantitative biosensors.
Collapse
Affiliation(s)
- Sunil Kumar Singh
- Department of Chemical Engineering, Indian Institute of Technology Guwahati, Assam 781039, India
| | - Aishwarya Srinivasan
- Department of Chemical Engineering, Indian Institute of Technology Guwahati, Assam 781039, India
| | - Shirsendu Mitra
- Department of Chemical Engineering, Indian Institute of Technology Guwahati, Assam 781039, India.
| | - Partho Sarathi Gooh Pattader
- Department of Chemical Engineering, Indian Institute of Technology Guwahati, Assam 781039, India; Centre for Nanotechnology, Indian Institute of Technology Guwahati, Assam 781039, India; School of Health Science and Technology, Indian Institute of Technology Guwahati, Assam 781039, India.
| |
Collapse
|
23
|
Georgas A, Lampas E, Houhoula DP, Skoufias A, Patsilinakos S, Tsafaridis I, Patrinos GP, Adamopoulos N, Ferraro A, Hristoforou E. ACE2-based capacitance sensor for rapid native SARS-CoV-2 detection in biological fluids and its correlation with real-time PCR. Biosens Bioelectron 2022; 202:114021. [PMID: 35092924 PMCID: PMC8776344 DOI: 10.1016/j.bios.2022.114021] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2021] [Revised: 01/13/2022] [Accepted: 01/17/2022] [Indexed: 12/14/2022]
Abstract
The spread of the SARS-CoV-2 and its increasing threat to human health worldwide have necessitated the development of new technological tools to combat the virus. Particular emphasis is given to the development of diagnostic methods that monitor the spread of the virus rapidly and effectively. In this study, we report the development and testing of an antibody-free biosensor, based on the immobilization of ACE2 protein on the surface of gold interdigitated electrode. When the sensor was used in laboratory conditions for targeting the virus' structural spike protein, it showed a limit of detection [LOD] of 750 pg/μL/mm2. Thereafter, the response of the sensor to swab and saliva samples from hospitalized patients was examined. The virus presence in the samples was confirmed by electrical effective capacitance measurements executed on the biosensor, and correlated with real-time PCR results. We verified that the biosensor can distinguish samples that are positive for the virus from those that are negative in a total of 7 positive and 16 negative samples. In addition, the biosensor can be used for semi-quantitative measurement, since its measurements are divided into 3 areas, the negative samples, the weakly positive and the positive samples. Reproducibility of the experiments was demonstrated with at least 3 replicates and stability was tested by keeping the sensor standby for 7 days at 4 °C before repeating the experiment. This work presents a biosensor that can be used as a fast-screening test at point of care detection of SARS-CoV-2 since it needs less than 2 min to provide results and is of simple operation.
Collapse
Affiliation(s)
- A Georgas
- National Technical University of Athens, Zografou Campus 9, Iroon Polytechniou str Zografou, 15780, Greece.
| | - E Lampas
- Konstantopoulio General Hospital, Agias Olgas 3-5, Nea Ionia, 142 33, Greece
| | - D P Houhoula
- University of West Attica, Agiou Spyridonos 28, Egaleo, 122 43, Greece
| | - A Skoufias
- National Technical University of Athens, Zografou Campus 9, Iroon Polytechniou str Zografou, 15780, Greece
| | - S Patsilinakos
- Konstantopoulio General Hospital, Agias Olgas 3-5, Nea Ionia, 142 33, Greece
| | - I Tsafaridis
- Katharsis Technologies Inc., 1200-1075, West Georgia Street, Vancouver, BC, Canada
| | - G P Patrinos
- University of Patras, University Campus, 26504, Rio, Greece
| | | | - A Ferraro
- National Technical University of Athens, Zografou Campus 9, Iroon Polytechniou str Zografou, 15780, Greece
| | - E Hristoforou
- National Technical University of Athens, Zografou Campus 9, Iroon Polytechniou str Zografou, 15780, Greece
| |
Collapse
|
24
|
Lyu D, Wang P, Zhang S, Liu G, Ren B. Revealing protein binding affinity on metal surfaces: an electrochemical approach. Chem Commun (Camb) 2022; 58:3537-3540. [PMID: 35195625 DOI: 10.1039/d1cc07098c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Revealing the binding affinity between viruses and surfaces of environmental matrices is crucial to evaluate the bioactivity of an immobilized virus and accompanying indirect virus-related infection pathways. The understanding for SARS-CoV-2 remaining infective for even days on stainless steel but only hours on copper is still unclear. Electrochemical chronoamperometry, ultrasensitive to interfacial capacitance on surface species, was used to investigate the binding affinity of SARS-CoV-2 on metal surfaces. SRBD, the surrogate of SARS-CoV-2, shows the highest adsorption capacity on a gold surface, followed by Cu, but lowest on a stainless steel surface. The strong binding of SRBD on copper is a result of the naturally grown Cu2O under ambient conditions. Measurement of electrochemical capacitance provides a simple strategy to explore and evaluate the potential risk of an indirect virus-related infection pathway through conductive environmental matrices.
Collapse
Affiliation(s)
- Danya Lyu
- State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
| | - Pingshi Wang
- State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
| | - Shuo Zhang
- State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
| | - Guokun Liu
- State Key Laboratory of Marine Environmental Science, College of the Environment and Ecology, Xiamen University, Xiamen 361005, China. .,Fujian Provincial Key Laboratory for Coastal Ecology and Environmental Studies, Center for Marine Environmental Chemistry & Toxicology, Xiamen University, Xiamen 361102, China
| | - Bin Ren
- State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
| |
Collapse
|
25
|
Gopal A, Yan L, Kashif S, Munshi T, Roy VAL, Voelcker NH, Chen X. Biosensors and Point-of-Care Devices for Bacterial Detection: Rapid Diagnostics Informing Antibiotic Therapy. Adv Healthc Mater 2022; 11:e2101546. [PMID: 34850601 DOI: 10.1002/adhm.202101546] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2021] [Revised: 11/20/2021] [Indexed: 02/06/2023]
Abstract
With an exponential rise in antimicrobial resistance and stagnant antibiotic development pipeline, there is, more than ever, a crucial need to optimize current infection therapy approaches. One of the most important stages in this process requires rapid and effective identification of pathogenic bacteria responsible for diseases. Current gold standard techniques of bacterial detection include culture methods, polymerase chain reactions, and immunoassays. However, their use is fraught with downsides with high turnaround time and low accuracy being the most prominent. This imposes great limitations on their eventual application as point-of-care devices. Over time, innovative detection techniques have been proposed and developed to curb these drawbacks. In this review, a systematic summary of a range of biosensing platforms is provided with a strong focus on technologies conferring high detection sensitivity and specificity. A thorough analysis is performed and the benefits and drawbacks of each type of biosensor are highlighted, the factors influencing their potential as point-of-care devices are discussed, and the authors' insights for their translation from proof-of-concept systems into commercial medical devices are provided.
Collapse
Affiliation(s)
- Ashna Gopal
- School of Engineering Institute for Bioengineering The University of Edinburgh Edinburgh EH9 3JL UK
| | - Li Yan
- College of Health Science and Environmental Engineering Shenzhen Technology University Shenzhen 518118 China
| | - Saima Kashif
- School of Engineering Institute for Bioengineering The University of Edinburgh Edinburgh EH9 3JL UK
| | - Tasnim Munshi
- School of Chemistry University of Lincoln, Brayford Pool Lincoln Lincolnshire LN6 7TS UK
| | | | - Nicolas H. Voelcker
- Drug Delivery Disposition and Dynamics Monash Institute of Pharmaceutical Sciences Monash University Parkville Victoria VIC 3052 Australia
- Melbourne Centre for Nanofabrication Victorian Node of the Australian National Fabrication Facility Clayton Victoria 3168 Australia
- Commonwealth Scientific and Industrial Research Organisation (CSIRO) Clayton Victoria 3168 Australia
| | - Xianfeng Chen
- School of Engineering Institute for Bioengineering The University of Edinburgh Edinburgh EH9 3JL UK
| |
Collapse
|
26
|
3D Impedimetric Biosensor for Cyanobacteria Detection in Natural Water Sources. CHEMOSENSORS 2021. [DOI: 10.3390/chemosensors10010007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The excessive growth of cyanobacteria in freshwater sources produces the development of toxic blooms mainly due to the production of cyanotoxins. Here, a novel impedimetric biosensor based on a three-dimensional interdigitated electrode array (3D-IDEA) for detection of cyanobacteria cells is reported. The 3D-IDEA sensor surface biofunctionalization was performed by means of the layer-by-layer method using polyethyleneimine (PEI) as the anchoring layer and concanavalin A (Con A) as the bioreceptor to lipopolysaccharides of cyanobacteria cells. The developed PEI-Con A 3D-IDEA sensors show a linear response (R2 = 0.992) of the impedance changes (RS) versus the logarithm of cyanobacteria concentrations in the range of 102–105 cells·mL−1 with the detection limit of 100 cells·mL−1. Moreover, to prevent the interference from components that may be present in real water samples and minimize a possible sample matrix effect, a filtration methodology to recover cyanobacterial cells was developed. The proposed methodology allows 91.2% bacteria recovery, permitting to obtain results similar to controlled assays. The developed system can be used in aquatic environments to detect cyanobacteria and consequently to prevent the formation of blooms and the production of cyanotoxins. Con A can bind to most polysaccharides and so react with other types of bacteria. However, currently, on the market, it is not possible to find specific biorecognition elements for cyanobacteria. Taking into consideration the specificity of samples to be analyzed (natural water resources), it is difficult to expect high concentration of other bacteria. In this sense, the developed methodology may be used as an alarm system to select samples for more thorough and precise laboratory analysis.
Collapse
|
27
|
Teeparuksapun K, Hedström M, Mattiasson B. A Sensitive Capacitive Biosensor for Protein a Detection Using Human IgG Immobilized on an Electrode Using Layer-by-Layer Applied Gold Nanoparticles. SENSORS (BASEL, SWITZERLAND) 2021; 22:99. [PMID: 35009642 PMCID: PMC8747357 DOI: 10.3390/s22010099] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/24/2021] [Revised: 11/20/2021] [Accepted: 11/23/2021] [Indexed: 06/14/2023]
Abstract
A capacitive biosensor for the detection of protein A was developed. Gold electrodes were fabricated by thermal evaporation and patterned by photoresist photolithography. A layer-by-layer (LbL) assembly of thiourea (TU) and HAuCl4 and chemical reduction was utilized to prepare a probe with a different number of layers of TU and gold nanoparticles (AuNPs). The LbL-modified electrodes were used for the immobilization of human IgG. The binding interaction between human IgG and protein A was detected as a decrease in capacitance signal, and that change was used to investigate the correlation between the height of the LbL probe and the sensitivity of the capacitive measurement. The results showed that the initial increase in length of the LbL probe can enhance the amount of immobilized human IgG, leading to a more sensitive assay. However, with thicker LbL layers, a reduction of the sensitivity of the measurement was registered. The performance of the developed system under optimum set-up showed a linearity in response from 1 × 10-16 to 1 × 10-13 M, with the limit detection of 9.1 × 10-17 M, which could be interesting for the detection of trace amounts of protein A from affinity isolation of therapeutic monoclonal antibodies.
Collapse
Affiliation(s)
- Kosin Teeparuksapun
- Science Program, Department of General Education, Faculty of Liberal Arts, Rajamangala University of Technology Srivijaya, Songkhla 90000, Thailand;
- Division of Biotechnology, Lund University, P.O. Box 124, 221 00 Lund, Sweden;
| | - Martin Hedström
- Division of Biotechnology, Lund University, P.O. Box 124, 221 00 Lund, Sweden;
| | - Bo Mattiasson
- Division of Biotechnology, Lund University, P.O. Box 124, 221 00 Lund, Sweden;
| |
Collapse
|
28
|
Kim J, Noh S, Park JA, Park SC, Park SJ, Lee JH, Ahn JH, Lee T. Recent Advances in Aptasensor for Cytokine Detection: A Review. SENSORS (BASEL, SWITZERLAND) 2021; 21:8491. [PMID: 34960590 PMCID: PMC8705356 DOI: 10.3390/s21248491] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Revised: 12/03/2021] [Accepted: 12/12/2021] [Indexed: 12/14/2022]
Abstract
Cytokines are proteins secreted by immune cells. They promote cell signal transduction and are involved in cell replication, death, and recovery. Cytokines are immune modulators, but their excessive secretion causes uncontrolled inflammation that attacks normal cells. Considering the properties of cytokines, monitoring the secretion of cytokines in vivo is of great value for medical and biological research. In this review, we offer a report on recent studies for cytokine detection, especially studies on aptasensors using aptamers. Aptamers are single strand nucleic acids that form a stable three-dimensional structure and have been receiving attention due to various characteristics such as simple production methods, low molecular weight, and ease of modification while performing a physiological role similar to antibodies.
Collapse
Affiliation(s)
- Jinmyeong Kim
- Department of Chemical Engineering, Kwangwoon University, 20 Kwangwoon-Ro, Nowon-gu, Seoul 01897, Korea; (J.K.); (S.N.); (J.A.P.)
| | - Seungwoo Noh
- Department of Chemical Engineering, Kwangwoon University, 20 Kwangwoon-Ro, Nowon-gu, Seoul 01897, Korea; (J.K.); (S.N.); (J.A.P.)
| | - Jeong Ah Park
- Department of Chemical Engineering, Kwangwoon University, 20 Kwangwoon-Ro, Nowon-gu, Seoul 01897, Korea; (J.K.); (S.N.); (J.A.P.)
| | - Sang-Chan Park
- Department of Electronics Engineering, Chungnam National University, 99 Yuseong-gu, Daejeon 34134, Korea;
| | - Seong Jun Park
- Department of Electrical Engineering, Kwangwoon University, 20 Kwangwoon-Ro, Nowon-gu, Seoul 01897, Korea;
| | - Jin-Ho Lee
- School of Biomedical Convergence Engineering, Pusan National University, 49 Busandaehak-ro, Yangsan 50612, Korea;
| | - Jae-Hyuk Ahn
- Department of Electronics Engineering, Chungnam National University, 99 Yuseong-gu, Daejeon 34134, Korea;
| | - Taek Lee
- Department of Chemical Engineering, Kwangwoon University, 20 Kwangwoon-Ro, Nowon-gu, Seoul 01897, Korea; (J.K.); (S.N.); (J.A.P.)
| |
Collapse
|
29
|
Mwanza D, Phal S, Nyokong T, Tesfalidet S, Mashazi P. Electrografting of isophthalic acid monolayer and covalent attachment of antibody onto carbon surfaces: Construction of capacitive biosensor for methotrexate detection. Electrochim Acta 2021. [DOI: 10.1016/j.electacta.2021.139360] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
30
|
Santos NAV, Pulido MTR, Tumacder DVC, Taaca KLM. Effect of polyaniline on the structural, conductivity, and dielectric properties of chitosan. CARBOHYDRATE POLYMER TECHNOLOGIES AND APPLICATIONS 2021. [DOI: 10.1016/j.carpta.2021.100129] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
31
|
Özmen EN, Kartal E, Turan MB, Yazıcıoğlu A, Niazi JH, Qureshi A. Graphene and carbon nanotubes interfaced electrochemical nanobiosensors for the detection of SARS-CoV-2 (COVID-19) and other respiratory viral infections: A review. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021; 129:112356. [PMID: 34579878 PMCID: PMC8339589 DOI: 10.1016/j.msec.2021.112356] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/24/2021] [Revised: 07/24/2021] [Accepted: 08/02/2021] [Indexed: 01/15/2023]
Abstract
Recent COVID-19 pandemic has claimed millions of lives due to lack of a rapid diagnostic tool. Global scientific community is now making joint efforts on developing rapid and accurate diagnostic tools for early detection of viral infections to preventing future outbreaks. Conventional diagnostic methods for virus detection are expensive and time consuming. There is an immediate requirement for a sensitive, reliable, rapid and easy-to-use Point-of-Care (PoC) diagnostic technology. Electrochemical biosensors have the potential to fulfill these requirements, but they are less sensitive for sensing viruses/viral infections. However, sensitivity and performance of these electrochemical platforms can be improved by integrating carbon nanostructure, such as graphene and carbon nanotubes (CNTs). These nanostructures offer excellent electrical property, biocompatibility, chemical stability, mechanical strength and, large surface area that are most desired in developing PoC diagnostic tools for detecting viral infections with speed, sensitivity, and cost-effectiveness. This review summarizes recent advancements made toward integrating graphene/CNTs nanostructures and their surface modifications useful for developing new generation of electrochemical nanobiosensors for detecting viral infections. The review also provides prospects and considerations for extending the graphene/CNTs based electrochemical transducers into portable and wearable PoC tools that can be useful in preventing future outbreaks and pandemics.
Collapse
Affiliation(s)
- Emine Nur Özmen
- Department of Molecular Biology and Genetics, Boğaziçi University, Bebek, 34342 Istanbul, Turkey
| | - Enise Kartal
- Department of Mechanical Engineering, Bilkent University, Ankara, Turkey
| | - Mehmet Bora Turan
- Department of Mechanical Engineering, Bilkent University, Ankara, Turkey
| | - Alperen Yazıcıoğlu
- Faculty of Engineering and Natural Sciences, Sabanci University, Orta Mahalle 34956, Tuzla, Istanbul, Turkey
| | - Javed H Niazi
- Sabanci University, SUNUM Nanotechnology Research and Application Center, Tuzla 34956, Istanbul, Turkey.
| | - Anjum Qureshi
- Sabanci University, SUNUM Nanotechnology Research and Application Center, Tuzla 34956, Istanbul, Turkey.
| |
Collapse
|
32
|
Dizon A, You C, Orazem ME. The influence of current and potential distribution on the measurement of dielectric permittivity. Electrochim Acta 2021. [DOI: 10.1016/j.electacta.2021.138957] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
33
|
Non-enzymatic and rapid detection of glucose on PVA-CuO thin film using ARDUINO UNO based capacitance measurement unit. Biomed Microdevices 2021; 23:36. [PMID: 34259948 DOI: 10.1007/s10544-021-00568-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/08/2021] [Indexed: 10/20/2022]
Abstract
Glucose measurement is one of the essential health monitoring practices for maintaining blood sugar levels. Here, we have fabricated a highly specific capacitive nano-sensor for non-enzymatic glucose detection. Capacitance measurements were carried out on polyvinyl alcohol capped copper oxide (PVA-CuO) thin films on indium tin oxide (ITO) coated glass using ARDUINO UNO. The capacitance study shows a decrease in capacitance with an increase in glucose concentrations. The applicability in real samples was performed by studying the glucose in the presence of fetal bovine serum. Most commonly found interfering agents were used for interference studies, which confirmed the capacitive nano-sensor specificity. The system was further checked for repeatability up to six readings and reproducibility up to 5 chips. The shelf-life study showed stability for four weeks of a chip. These studies indicate that this capacitance-based measurement unit can be used for reliable, rapid, and non-enzymatic detection of glucose in real sample.
Collapse
|
34
|
Khodayari Bavil A, Sticker D, Rothbauer M, Ertl P, Kim J. A microfluidic microparticle-labeled impedance sensor array for enhancing immunoassay sensitivity. Analyst 2021; 146:3289-3298. [PMID: 33999058 DOI: 10.1039/d0an02081h] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
An impedimetric biosensor is used to measure electrical impedance changes in the presence of biomolecules from sinusoidal input voltages. In this paper, we present a new portable impedance-based biosensor platform to improve the sensitivity of immunoassays with microparticles as a label. Using a 2 × 4 interdigitated electrode array with a 10/10 μm electrode/gap and a miniaturized impedance analyzer, we performed immunoassays with microparticles by integrating a microfluidic channel to evaluate signal enhancement. First, to understand the material dependency of microparticles on the sensor array, magnetic, silica, and polystyrene microparticles were tested. Among these microparticles, magnetic microparticles presented a high signal enhancement with relevant stability from the sensor array. With the magnetic microparticles, we demonstrate a series of immunoassays to detect human tumor necrosis factor (TNF-α) and compare the level of signal enhancement by measuring the limit of detection (LOD). With the microparticles, we achieved over ten times improvement of LOD from sandwich immunoassays. By incorporating with sample preparation and flow manipulation systems, this impedance sensor array can be utilized for digital diagnostics for a real sample-in answer-out system.
Collapse
Affiliation(s)
- Ali Khodayari Bavil
- Department of Mechanical Engineering, University of Utah, Salt Lake City, UT, USA.
| | | | | | | | | |
Collapse
|
35
|
Reagentless Affimer- and antibody-based impedimetric biosensors for CEA-detection using a novel non-conducting polymer. Biosens Bioelectron 2021; 178:113013. [PMID: 33508539 DOI: 10.1016/j.bios.2021.113013] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2020] [Revised: 12/31/2020] [Accepted: 01/15/2021] [Indexed: 11/21/2022]
Abstract
Polyoctopamine (POct), an amine-functionalised non-conducting polymer, as the transducer layer in an electrochemical biosensor, is presented. This polymer offers versatile covalent coupling either through thiol linker conjugation, carboxyl or aldehyde functional groups without the requirement of pre- or post-surface activation. The colorectal cancer biomarker carcinoembryonic antigen (CEA) was selected as the target analyte, whilst an antibody and a synthetic binding protein, an Affimer, were used as distinct bioreceptors to demonstrate the versatility of polyoctopamine as a transducer polymer layer for oriented immobilisation of the bioreceptors. The electrodeposited polymer layer was characterised using cyclic voltammetry, electrochemical impedance spectroscopy, and on-sensor chemiluminescent blotting. The performance of optimised POct-based biosensors were tested in spiked human serum. Results showed that the electropolymerisation of octopamine on screen printed gold electrode generates a thin polymer film with low resistance. Close proximity of the immobilised bioreceptors to the transducer layer greatly enhanced the sensitivity detection. The sensitivity of the smaller monomeric bioreceptor (Affimer, 12.6 kDa) to detect CEA was comparable to the dimeric antibody (150 kDa) with limit of detection at 11.76 fM which is significantly lower than the basal clinical levels of 25 pM. However, the Affimer-based sensor had a narrower dynamic range compared to the immunosensor (1-100 fM vs. 1 fM - 100 nM, respectively). All electrochemical measurements were done in less than 5 min with small sample volumes (10 μl). Hence, polyoctopamine features a simple fabrication of impedimetric biosensors using amine-functionalisation technique, provides rapid response time with enhanced sensitivity and label-free detection.
Collapse
|
36
|
Ranjan P, Singhal A, Yadav S, Kumar N, Murali S, Sanghi SK, Khan R. Rapid diagnosis of SARS-CoV-2 using potential point-of-care electrochemical immunosensor: Toward the future prospects. Int Rev Immunol 2021; 40:126-142. [PMID: 33448909 DOI: 10.1080/08830185.2021.1872566] [Citation(s) in RCA: 41] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
Coronavirus disease (COVID-19) is an emerging and highly infectious disease making global public health concern and socio-economic burden. It is caused due to Severe Acute Respiratory Syndrome Coronavirus (SARS-CoV-2). It has the tendency to spread rapidly through person-to-person. Currently, several molecular diagnostic platforms such as PCR, qRT-PCR, reverse transcription loop-mediated isothermal amplification (RT-LAMP), CRISPR are utilized for the diagnosis of SARS-CoV-2. These conventional techniques are costly, time consuming and require sophisticated instrumentation facility with well trained personnel for testing. Hence, it is tough to provide testing en-masse to the people in developing countries. On the other hand, several serological biosensors such as lateral flow immunosensor, optical, electrochemical, microfluidics integrated electrochemical/fluorescence is currently utilized for the diagnosis of SARS-CoV-2. In current pandemic situation, there is an urgent need of rapid and efficient diagnosis on mass scale of SARS-CoV-2 for early stage detection. Early monitoring of viral infections can help to control and prevent the spreading of infections in large chunk of population. In this review, the SARS-CoV-2 and their biomarkers in biological samples, collection of samples and recently reported potential electrochemical immunosensors for the rapid diagnosis of SARS-CoV-2 are discussed.
Collapse
Affiliation(s)
- Pushpesh Ranjan
- Microfluidics and MEMS Centre, CSIR - Advanced Materials and Processes Research Institute (AMPRI), Bhopal, India.,Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, India
| | - Ayushi Singhal
- Microfluidics and MEMS Centre, CSIR - Advanced Materials and Processes Research Institute (AMPRI), Bhopal, India.,Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, India
| | - Shalu Yadav
- Microfluidics and MEMS Centre, CSIR - Advanced Materials and Processes Research Institute (AMPRI), Bhopal, India.,Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, India
| | - Neeraj Kumar
- Microfluidics and MEMS Centre, CSIR - Advanced Materials and Processes Research Institute (AMPRI), Bhopal, India.,Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, India
| | - S Murali
- Microfluidics and MEMS Centre, CSIR - Advanced Materials and Processes Research Institute (AMPRI), Bhopal, India
| | - Sunil K Sanghi
- Microfluidics and MEMS Centre, CSIR - Advanced Materials and Processes Research Institute (AMPRI), Bhopal, India
| | - Raju Khan
- Microfluidics and MEMS Centre, CSIR - Advanced Materials and Processes Research Institute (AMPRI), Bhopal, India.,Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, India
| |
Collapse
|
37
|
Öztürk M, Okutan M, Coşkun R, Çolak B, Yalçın O. Evaluation of the effect of dose change of Fe3O4 nanoparticles on electrochemical biosensor compatibility using hydrogels as an experimental living organism model. J Mol Liq 2021. [DOI: 10.1016/j.molliq.2020.114574] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
38
|
Rashed MZ, Kopechek JA, Priddy MC, Hamorsky KT, Palmer KE, Mittal N, Valdez J, Flynn J, Williams SJ. Rapid detection of SARS-CoV-2 antibodies using electrochemical impedance-based detector. Biosens Bioelectron 2021; 171:112709. [PMID: 33075724 PMCID: PMC7539830 DOI: 10.1016/j.bios.2020.112709] [Citation(s) in RCA: 115] [Impact Index Per Article: 28.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Revised: 10/01/2020] [Accepted: 10/06/2020] [Indexed: 01/06/2023]
Abstract
Coronavirus disease (COVID-19) caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) was classified as a pandemic by the World Health Organization and has caused over 550,000 deaths worldwide as of July 2020. Accurate and scalable point-of-care devices would increase screening, diagnosis, and monitoring of COVID-19 patients. Here, we demonstrate rapid label-free electrochemical detection of SARS-CoV-2 antibodies using a commercially available impedance sensing platform. A 16-well plate containing sensing electrodes was pre-coated with receptor binding domain (RBD) of SARS-CoV-2 spike protein, and subsequently tested with samples of anti-SARS-CoV-2 monoclonal antibody CR3022 (0.1 μg/ml, 1.0 μg/ml, 10 μg/ml). Subsequent blinded testing was performed on six serum specimens taken from COVID-19 and non-COVID-19 patients (1:100 dilution factor). The platform was able to differentiate spikes in impedance measurements from a negative control (1% milk solution) for all CR3022 samples. Further, successful differentiation and detection of all positive clinical samples from negative control was achieved. Measured impedance values were consistent when compared to standard ELISA test results showing a strong correlation between them (R2=0.9). Detection occurs in less than five minutes and the well-based platform provides a simplified and familiar testing interface that can be readily adaptable for use in clinical settings.
Collapse
Affiliation(s)
- Mohamed Z Rashed
- Department of Mechanical Engineering, University of Louisville, 200 Sackett Hall, Louisville, KY 40208, USA.
| | - Jonathan A Kopechek
- Department of Bioengineering, University of Louisville, Louisville, KY 40208, USA
| | - Mariah C Priddy
- Department of Bioengineering, University of Louisville, Louisville, KY 40208, USA
| | - Krystal T Hamorsky
- Center for Predictive Medicine for Biodefense and Emerging Infectious Diseases, University of Louisville, Louisville, KY 40208, USA
| | - Kenneth E Palmer
- Center for Predictive Medicine for Biodefense and Emerging Infectious Diseases, University of Louisville, Louisville, KY 40208, USA
| | - Nikhil Mittal
- ACEA Biosciences, Agilent Technologies Inc., San Diego, CA 92121, USA
| | - Joseph Valdez
- ACEA Biosciences, Agilent Technologies Inc., San Diego, CA 92121, USA
| | - Joseph Flynn
- Norton Healthcare, Inc, Louisville, KY 40202, USA
| | - Stuart J Williams
- Department of Mechanical Engineering, University of Louisville, 200 Sackett Hall, Louisville, KY 40208, USA.
| |
Collapse
|
39
|
Kluge N, Dacey M, Hadaya J, Shivkumar K, Chan SA, Ardell JL, Smith C. Rapid measurement of cardiac neuropeptide dynamics by capacitive immunoprobe in the porcine heart. Am J Physiol Heart Circ Physiol 2021; 320:H66-H76. [PMID: 33095651 PMCID: PMC7847069 DOI: 10.1152/ajpheart.00674.2020] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/17/2020] [Revised: 10/22/2020] [Accepted: 10/22/2020] [Indexed: 01/09/2023]
Abstract
Sympathetic control of regional cardiac function occurs through postganglionic innervation from stellate ganglia and thoracic sympathetic chain. Whereas norepinephrine (NE) is their primary neurotransmitter, neuropeptide Y (NPY) is an abundant cardiac cotransmitter. NPY plays a vital role in homeostatic processes including angiogenesis, vasoconstriction, and cardiac remodeling. Elevated sympathetic stress, resulting in increased NE and NPY release, has been implicated in the pathogenesis of several cardiovascular disorders including hypertension, myocardial infarction, heart failure, and arrhythmias, which may result in sudden cardiac death. Current methods for the detection of NPY in myocardium are limited in their spatial and temporal resolution and take days to weeks to provide results [e.g., interstitial microdialysis with subsequent analysis by enzyme-linked immunosorbent assay (ELISA), high performance liquid chromatography (HPLC), or mass spectrometry]. In this study, we report a novel approach for measurement of interstitial and intravascular NPY using a minimally invasive capacitive immunoprobe (C.I. probe). The first high-spatial and temporal resolution, multichannel measurements of NPY release in vivo are provided in both myocardium and transcardiac vascular space in a beating porcine heart. We provide NPY responses evoked by sympathetic stimulation and ectopic ventricular pacing and compare these to NE release and hemodynamic responses. We extend this approach to measure both NPY and vasoactive intestinal peptide (VIP) and show differential release profiles under sympathetic stimulation. Our data demonstrate rapid and local changes in neurotransmitter profiles in response to sympathetic cardiac stressors. Future implementations include real-time intraoperative determination of cardiac neuropeptides and deployment as a minimally invasive catheter.NEW & NOTEWORTHY The sympathetic nervous system regulates cardiac function through release of neurotransmitters and neuropeptides within the myocardium. Neuropeptide Y (NPY) acts as an acute cardiac vasoconstrictor and chronically to regulate angiogenesis and cardiac remodeling. Current methodologies for the measure of NPY are not capable of providing rapid readouts on a single-sample basis. Here we provide the first in vivo methodology to report dynamic, localized NPY levels within both myocardium and vascular compartments in a beating heart.
Collapse
Affiliation(s)
- Nicholas Kluge
- Department of Physiology and Biophysics, Case Western Reserve University, Cleveland, Ohio
| | - Michael Dacey
- UCLA Cardiac Arrhythmia Center, David Geffen School of Medicine, University of California, Los Angeles, California
- UCLA Neurocardiology Research Program of Excellence, University of California, Los Angeles, California
- Molecular, Cellular, and Integrative Physiology Program, University of California, Los Angeles, California
| | - Joseph Hadaya
- UCLA Cardiac Arrhythmia Center, David Geffen School of Medicine, University of California, Los Angeles, California
- UCLA Neurocardiology Research Program of Excellence, University of California, Los Angeles, California
- Molecular, Cellular, and Integrative Physiology Program, University of California, Los Angeles, California
| | - Kalyanam Shivkumar
- UCLA Cardiac Arrhythmia Center, David Geffen School of Medicine, University of California, Los Angeles, California
- UCLA Neurocardiology Research Program of Excellence, University of California, Los Angeles, California
| | - Shyue-An Chan
- Department of Physiology and Biophysics, Case Western Reserve University, Cleveland, Ohio
| | - Jeffrey L Ardell
- UCLA Cardiac Arrhythmia Center, David Geffen School of Medicine, University of California, Los Angeles, California
- UCLA Neurocardiology Research Program of Excellence, University of California, Los Angeles, California
| | - Corey Smith
- Department of Physiology and Biophysics, Case Western Reserve University, Cleveland, Ohio
| |
Collapse
|
40
|
Dar KK, Shao S, Tan T, Lv Y. Molecularly imprinted polymers for the selective recognition of microorganisms. Biotechnol Adv 2020; 45:107640. [DOI: 10.1016/j.biotechadv.2020.107640] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2020] [Revised: 09/18/2020] [Accepted: 10/01/2020] [Indexed: 12/20/2022]
|
41
|
Le HTN, Park J, Cho S. A Probeless Capacitive Biosensor for Direct Detection of Amyloid Beta 1-42 in Human Serum Based on an Interdigitated Chain-Shaped Electrode. MICROMACHINES 2020; 11:E791. [PMID: 32825726 PMCID: PMC7569882 DOI: 10.3390/mi11090791] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Revised: 08/19/2020] [Accepted: 08/19/2020] [Indexed: 12/16/2022]
Abstract
Amyloid beta (aβ) 1-42, a peptide that is 1-42 amino acids long, is a major component of senile plaques in the brains of patients with Alzheimer's disease. Aβ detection has become an essential antecedence to predict the declining mental abilities of patients. In this paper, a probeless capacitive biosensor for the non-Faradaic detection of aβ 1-42 peptide was developed by immobilizing a specific anti-aβ antibody onto a self-assembled monolayer functionalized interdigitated chain-shaped electrode (anti-aβ/SAM/ICE). The novelty and difference of this article from previous studies is the direct detection of aβ peptide with no redox probe ((Fe(CN)6)3-/4-), which can avoid the denaturation of the protein caused by the metallization (binding of aβ to metal ion Fe which is presented in the redox couple). The direct detection of aβ with no redox probe is performed by non-Faradaic capacitive measurement, which is greatly different from the Faradaic measurement of the charge transfer resistance of the redox probe. The detection of various aβ 1-42 peptide concentrations in human serum (HS) was performed by measuring the relative change in electrode interfacial capacitance due to the specific antibody-aβ binding. Capacitance change in the anti-aβ/SAM/ICE biosensor showed a linear detection range between 10 pg mL-1 and 104 pg mL-1, and a detection limit of 7.5 pg mL-1 in HS, which was much lower than the limit of detection for CSF aβ 1-42 (~500 pg mL-1) and other biosensors. The small dissociation constant Kd of the antibody-antigen interaction was also found to be 0.016 nM in HS, indicating the high binding affinity of the anti-aβ/SAM/ICE biosensor in the recognizing of aβ 1-42. Thus, the developed sensor can be used for label-free and direct measurement of aβ 1-42 peptide and for point-of-care diagnosis of Alzheimer's disease without redox probe.
Collapse
Affiliation(s)
- Hien T. Ngoc Le
- Department of Electronic Engineering, Gachon University, Seongnam-si, Gyeonggi-do 13120, Korea;
| | - Jinsoo Park
- Department of Health Sciences and Technology, GAIHST, Gachon University, Incheon 21999, Korea;
| | - Sungbo Cho
- Department of Electronic Engineering, Gachon University, Seongnam-si, Gyeonggi-do 13120, Korea;
- Department of Health Sciences and Technology, GAIHST, Gachon University, Incheon 21999, Korea;
| |
Collapse
|
42
|
Impedimetric Aptamer-Based Biosensors: Principles and Techniques. ADVANCES IN BIOCHEMICAL ENGINEERING/BIOTECHNOLOGY 2020; 174:17-41. [PMID: 32328684 DOI: 10.1007/10_2019_113] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Aptamers are a specific class of ligands with high affinities comparable to antibodies, which are selected and synthesized in vitro. In combination with impedance spectroscopy as sensitive measurement method, we gain a class of biosensors with high potential for handheld devices and point-of-care tests. In this review, we report on recent advances in aptamer-based impedimetric biosensors. Besides giving a short summary of electrochemical measurement techniques, the most exciting innovative developments of detection strategies in the last decades are reviewed. Finally, important criteria for the comparison of aptamer-based biosensors are discussed.
Collapse
|
43
|
Cesewski E, Johnson BN. Electrochemical biosensors for pathogen detection. Biosens Bioelectron 2020; 159:112214. [PMID: 32364936 PMCID: PMC7152911 DOI: 10.1016/j.bios.2020.112214] [Citation(s) in RCA: 385] [Impact Index Per Article: 77.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2019] [Revised: 04/09/2020] [Accepted: 04/10/2020] [Indexed: 12/19/2022]
Abstract
Recent advances in electrochemical biosensors for pathogen detection are reviewed. Electrochemical biosensors for pathogen detection are broadly reviewed in terms of transduction elements, biorecognition elements, electrochemical techniques, and biosensor performance. Transduction elements are discussed in terms of electrode material and form factor. Biorecognition elements for pathogen detection, including antibodies, aptamers, and imprinted polymers, are discussed in terms of availability, production, and immobilization approach. Emerging areas of electrochemical biosensor design are reviewed, including electrode modification and transducer integration. Measurement formats for pathogen detection are classified in terms of sample preparation and secondary binding steps. Applications of electrochemical biosensors for the detection of pathogens in food and water safety, medical diagnostics, environmental monitoring, and bio-threat applications are highlighted. Future directions and challenges of electrochemical biosensors for pathogen detection are discussed, including wearable and conformal biosensors, detection of plant pathogens, multiplexed detection, reusable biosensors for process monitoring applications, and low-cost, disposable biosensors.
Collapse
Affiliation(s)
- Ellen Cesewski
- Department of Industrial and Systems Engineering, Virginia Tech, Blacksburg, VA, 24061, USA; Department of Materials Science and Engineering, Virginia Tech, Blacksburg, VA, 24061, USA
| | - Blake N Johnson
- Department of Industrial and Systems Engineering, Virginia Tech, Blacksburg, VA, 24061, USA; Department of Materials Science and Engineering, Virginia Tech, Blacksburg, VA, 24061, USA; Department of Chemical Engineering, Virginia Tech, Blacksburg, VA, 24061, USA.
| |
Collapse
|
44
|
Kordasht HK, Hassanpour S, Baradaran B, Nosrati R, Hashemzaei M, Mokhtarzadeh A, la Guardia MD. Biosensing of microcystins in water samples; recent advances. Biosens Bioelectron 2020; 165:112403. [PMID: 32729523 DOI: 10.1016/j.bios.2020.112403] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2020] [Revised: 06/16/2020] [Accepted: 06/19/2020] [Indexed: 02/07/2023]
Abstract
Safety and quality of water are significant matters for agriculture, animals and human health. Microcystins, as secondary metabolite of cyanobacteria (blue-green algae) and cyclic heptapeptide cyanotoxin, are one of the main marine toxins in continental aquatic ecosystems. More than 100 microcystins have been identified, of which MC-LR is the most important type due to its high toxicity and common detection in the environment. Climate change is an impressive factor with effects on cyanobacterial blooms as source of microcystins. The presence of this cyanotoxin in freshwater, drinking water, water reservoir supplies and food (vegetable, fish and shellfish) has created a common phenomenon in eutrophic freshwater ecosystems worldwide. International public health organizations have categorized microcystins as a kind of neurotoxin and carcinogen. There are several conventional methods for detection of microcystins. The limitations of traditional methods have encouraged the development of innovative methods for detection of microcystins. In recent years, the developed sensor techniques, with advantages, such as accuracy, reproducibility, portability and low cost, have attracted considerable attention. This review compares the well-known of biosensor types for detection of microcystins with a summary of their analytical performance.
Collapse
Affiliation(s)
- Houman Kholafazad Kordasht
- Department of Food Hygiene and Aquatic, Faculty of Veterinary Medicine, University of Tabriz, Tabriz, Iran
| | - Soodabeh Hassanpour
- Department of Analytical Chemistry, Faculty of Science, Palacky University Olomouc, 17. Listopadu 12, 77146, Olomouc, Czech Republic
| | - Behzad Baradaran
- Immunology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Rahim Nosrati
- Department of Pharmaceutical Biotechnology, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran; Cellular and Molecular Research Center, School of Medicine, Guilan University of Medical Sciences, Rasht, Iran
| | - Mahmoud Hashemzaei
- Department of Pharmacodynamics and Toxicology, School of Pharmacy, Zabol University of Medical Sciences, Zabol, Iran
| | - Ahad Mokhtarzadeh
- Immunology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.
| | - Miguel de la Guardia
- Department of Analytical Chemistry, University of Valencia, Dr. Moliner 50, 46100, Burjassot, Valencia, Spain.
| |
Collapse
|
45
|
|
46
|
Song C, Peng Z, Lin X, Luo H, Song M, Jin L, Xiao X, Ji H. Study on Interaction Between TATA-Box Binding Protein (TBP), TATA-Box and Multiprotein Bridging Factor 1(MBF1) in Beauveria bassiana by Graphene-Based Electrochemical Biosensors. Front Chem 2020; 8:278. [PMID: 32351940 PMCID: PMC7174728 DOI: 10.3389/fchem.2020.00278] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2020] [Accepted: 03/23/2020] [Indexed: 11/13/2022] Open
Abstract
The regulation of transcription level is an important step in gene expression process. Beauveria bassiana is a broad-spectrum insecticidal fungi widely used in the biologic control of arthropod. The regulation of its transcription level is a multilevel complex process. Multiprotein bridging factor 1(MBF1) is a transcriptional co-activator that bridges sequence-specific activators and the TATA-box binding protein(TBP), Little is known about the interaction between MBF1, TBP, and TBP binding to DNA(TATA-sequences)in filamentous fungi of Beauveria bassiana, The binding of TBP to TATA-box and TBP to MBF1 was investigated via electrochemical biosensor. Graphene oxide has an electronic mobility that is unattainable for any metal, so it will be highly sensitive as a test electrode. Hence, we developed a simple, sensitive and specific sensor based on an TBP probe and graphene oxide that successfully detected the interaction of TBP and TATA-box or MBF1. From the electrochemical impedance spectroscopy (EIS), we find that the radius will increase when adding TATA-box or MBF1 buffer to the modified TBP protein electrode. When adding no TATA-box or no MBF1, the radius is relatively unchanged. The interaction between TBP and TATA-box or MBF1 was proved based on the results. These data confirmed the specificity of the interactions, (1) our developed graphene-based electrochemical biosensor can be used for monitoring the interaction between TBP and TATA-box or MBF1, (2) TBP can bind to TATA-box, (3) TBP can bind to MBF1, and (4) TBP mediates the interactions of MBF1 to DNA. Therefore, this work provided a label-free, low-cost and simple detection method for the complex process of eukaryotic gene transcription regulation.
Collapse
Affiliation(s)
- Chi Song
- Department of Life Science and Technology, Changshu Institute of Technology, Changshu, China
| | - Zhijia Peng
- Key Laboratory of Optoelectronic Technology and Systems of Ministry of Education of China, Chongqing University, Chongqing, China
| | - Xiaogang Lin
- Key Laboratory of Optoelectronic Technology and Systems of Ministry of Education of China, Chongqing University, Chongqing, China
| | - Haoyue Luo
- Key Laboratory of Optoelectronic Technology and Systems of Ministry of Education of China, Chongqing University, Chongqing, China
| | - Min Song
- Key Laboratory of Optoelectronic Technology and Systems of Ministry of Education of China, Chongqing University, Chongqing, China
| | - Lifeng Jin
- Key Laboratory of Optoelectronic Technology and Systems of Ministry of Education of China, Chongqing University, Chongqing, China
| | - Xiangyue Xiao
- Department of Life Science and Technology, Changshu Institute of Technology, Changshu, China
| | - Hong Ji
- Department of Life Science and Technology, Changshu Institute of Technology, Changshu, China
| |
Collapse
|
47
|
A capacitive immunosensor for tetracycline estimation using antibody modified polytyramine-alkanethiol ultra-thin film on gold. J Electroanal Chem (Lausanne) 2020. [DOI: 10.1016/j.jelechem.2020.114055] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
48
|
Neshani S, Nyamekye CKA, Melvin S, Smith EA, Chen DJ, Neihart NM. AC and DC Differential Bridge Structure Suitable for Electrochemical Interfacial Capacitance Biosensing Applications. BIOSENSORS 2020; 10:E28. [PMID: 32235710 PMCID: PMC7146243 DOI: 10.3390/bios10030028] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/12/2020] [Revised: 03/18/2020] [Accepted: 03/19/2020] [Indexed: 11/16/2022]
Abstract
This paper presents a capacitive differential bridge structure with both AC and DC excitation and balancing capability for low cost electrode-solution interfacial capacitance biosensing applications. The proposed series RC balancing structure offers higher sensitivity, lower susceptibility to common-mode interferences, and drift control. To evaluate the bridge performance in practice, possible effects of initial bridge imbalance due to component mismatches are investigated considering the required resolution of the balancing networks, sensitivity, and linearity. This evaluation is also a guideline to designing the balancing networks, balancing algorithm and the proceeding readout interface circuitry. The proposed series RC bridge structure is implemented along with a custom single frequency real-time amplification/filtering readout board with real-time data acquisition and sine fitting. The main specifications for the implemented structure are 8-bit detection resolution if the total expected fractional capacitance change at the interface is roughly 1%. The characterization and measurement results show the effectiveness of the proposed structure in achieving the design target. The implemented structure successfully achieves distinct detection levels for tiny total capacitance change at the electrode-solution interface, utilizing Microcystin-(Leucine-Arginine) toxin dilutions as a proof of concept.
Collapse
Affiliation(s)
- Sara Neshani
- Electrical Engineering Department, Iowa State University, Ames, IA 50010, USA
| | | | - Scott Melvin
- Electrical Engineering Department, Iowa State University, Ames, IA 50010, USA
| | - Emily A Smith
- Department of Chemistry, Iowa State University, Ames, IA 50010, USA
| | - Degang J Chen
- Electrical Engineering Department, Iowa State University, Ames, IA 50010, USA
| | - Nathan M Neihart
- Electrical Engineering Department, Iowa State University, Ames, IA 50010, USA
| |
Collapse
|
49
|
Deshmukh R, Prusty AK, Roy U, Bhand S. A capacitive DNA sensor for sensitive detection ofEscherichia coliO157:H7 in potable water based on thez3276genetic marker: fabrication and analytical performance. Analyst 2020; 145:2267-2278. [DOI: 10.1039/c9an02291k] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
We report a label-free biosensor for the detection ofEscherichia coliO157:H7 ATCC 43895 in potable water using a newly designed DNA sensing probe targeting thez3276genetic marker.
Collapse
Affiliation(s)
- Rehan Deshmukh
- Birla institute of Technology and Science
- Pilani
- Department of Biological Sciences
- India
| | - Arun Kumar Prusty
- Birla institute of Technology and Science
- Pilani
- Department of Chemistry
- India
| | - Utpal Roy
- Birla institute of Technology and Science
- Pilani
- Department of Biological Sciences
- India
| | - Sunil Bhand
- Birla institute of Technology and Science
- Pilani
- Department of Chemistry
- India
| |
Collapse
|
50
|
Kim K, Lee CH, Park CB. Chemical sensing platforms for detecting trace-level Alzheimer's core biomarkers. Chem Soc Rev 2020; 49:5446-5472. [DOI: 10.1039/d0cs00107d] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
This review provides an overview of recent advances in optical and electrical detection of Alzheimer's disease biomarkers in clinically relevant fluids.
Collapse
Affiliation(s)
- Kayoung Kim
- Department of Materials Science and Engineering
- Korea Advanced Institute of Science and Technology (KAIST)
- Daejeon 305-701
- Republic of Korea
| | - Chang Heon Lee
- Department of Materials Science and Engineering
- Korea Advanced Institute of Science and Technology (KAIST)
- Daejeon 305-701
- Republic of Korea
| | - Chan Beum Park
- Department of Materials Science and Engineering
- Korea Advanced Institute of Science and Technology (KAIST)
- Daejeon 305-701
- Republic of Korea
| |
Collapse
|