1
|
Electrophysiological properties of dorsal root ganglion neurons cultured on 3D silicon micro-pillar substrates. J Neurosci Methods 2024; 407:110143. [PMID: 38670536 DOI: 10.1016/j.jneumeth.2024.110143] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Revised: 02/27/2024] [Accepted: 04/20/2024] [Indexed: 04/28/2024]
Abstract
BACKGROUND Silicon-based micro-pillar substrates (MPS), as three-dimensional cell culture platforms with vertically aligned micro-patterned scaffolding structures, are known to facilitate high-quality growth and morphology of dorsal root ganglion (DRG) sensory neurons, promote neurite outgrowth and enhance neurite alignment. However, the electrophysiological aspects of DRG neurons cultured on silicon MPSs have not been thoroughly investigated, which is of greatest importance to ensure that such substrates do not disrupt neuronal homeostasis and function before their widespread adoption in diverse biomedical applications. NEW METHOD We conducted whole-cell patch-clamp recordings to explore the electrophysiological properties of DRG neurons cultured on MPS arrays, utilizing a custom-made upright patch-clamp setup. RESULTS Our findings revealed that DRG neurons exhibited similar electrophysiological responses on patterned MPS samples when compared to the control planar glass surfaces. Notably, there were no significant differences observed in the action potential parameters or firing patterns of action potentials between neurons grown on either substrate. COMPARISON WITH EXISTING METHODS In the current study we for the first time confirmed that successful electrophysiological recordings can be obtained from the cells grown on MPS. CONCLUSION Our results imply that, despite the potential alterations caused by the cumulative trauma of tissue harvest and cell dissociation, essential functional cell properties of DRG neurons appear to be relatively maintained on MPS surfaces. Therefore, vertically aligned silicon MPSs could be considered as a potentially effective three-dimensional system for supporting a controlled cellular environment in culture.
Collapse
|
2
|
Abstract
The automated patch clamp (APC) technology is used for increasing the data throughput of electrophysiological measurements, especially in safety pharmacology and drug discovery. Typically, electrical access to the cells are obtained using standard whole-cell formation by rupturing the membrane, thereby causing a rapid washout of cytosolic components. In contrast the perforated whole-cell configuration provides electrical access to the cell interior while limiting intracellular wash-out. This method allows for recordings of ion channels that are gated by intracellular modulators (e.g., ATP, cyclic nucleotides, or Ca2+), prevents channel current "run down," and maintains a physiological membrane potential for action potential recordings. Here we present some practical approaches to the use of perforated patch clamp for APC recordings. Our findings from these high-throughput, data-rich measurements (e.g., defining optimized concentrations and practical recommendations for four different perforating agents) can be more broadly applied to perforated patch clamp experiments in general (automated and manual), improving success rates, experimental conditions, and applications.
Collapse
|
3
|
Abstract
To understand how the brain functions we need to understand the properties of its constituent cells. Whole-cell patch-clamp recordings of neurons have enabled studies of their intrinsic electrical properties as well as their synaptic connectivity within neural circuits. Recent technological advances have now made it possible to combine this with a sampling of their transcriptional profile. Here we provide a detailed description how to combine whole-cell patch-clamp recordings of neurons in brain slices followed by extraction of their cytoplasm suitable for single-cell RNA sequencing and analysis.
Collapse
|
4
|
In vivo patch-clamp recordings reveal distinct subthreshold signatures and threshold dynamics of midbrain dopamine neurons. Nat Commun 2020; 11:6286. [PMID: 33293613 PMCID: PMC7722714 DOI: 10.1038/s41467-020-20041-2] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2020] [Accepted: 11/06/2020] [Indexed: 01/19/2023] Open
Abstract
The in vivo firing patterns of ventral midbrain dopamine neurons are controlled by afferent and intrinsic activity to generate sensory cue and prediction error signals that are essential for reward-based learning. Given the absence of in vivo intracellular recordings during the last three decades, the subthreshold membrane potential events that cause changes in dopamine neuron firing patterns remain unknown. To address this, we established in vivo whole-cell recordings and obtained over 100 spontaneously active, immunocytochemically-defined midbrain dopamine neurons in isoflurane-anaesthetized adult mice. We identified a repertoire of subthreshold membrane potential signatures associated with distinct in vivo firing patterns. Dopamine neuron activity in vivo deviated from single-spike pacemaking by phasic increases in firing rate via two qualitatively distinct biophysical mechanisms: 1) a prolonged hyperpolarization preceding rebound bursts, accompanied by a hyperpolarizing shift in action potential threshold; and 2) a transient depolarization leading to high-frequency plateau bursts, associated with a depolarizing shift in action potential threshold. Our findings define a mechanistic framework for the biophysical implementation of dopamine neuron firing patterns in the intact brain.
Collapse
|
5
|
Abstract
The P2X7 receptor [P2X7R or P2RX7 in National Center for Biotechnology Information (NCBI) gene nomenclature] is a member of the P2X receptor (P2XR) subfamily of P2 receptors (P2Rs). The P2X7R is an extracellular ATP-gated ion channel with peculiar permeability properties expressed by most cell types, mainly in the immune system, where it has a leading role in cytokine release, oxygen radical generation, T lymphocyte differentiation and proliferation. A role in cancer cell growth and tumor progression has also been demonstrated. These features make the P2X7R an appealing target for drug development in inflammation and cancer. The functional P2X7R, recently (partially) crystallized and 3-D solved, is formed by the assembly of three identical subunits (homotrimer). The P2X7R is preferentially permeable to small cations (Ca2+, Na+, K+), and in most (but not all) cell types also to large positively charged molecules of molecular mass up to 900Da. Permeability to negatively charged species of comparable molecular mass (e.g., Lucifer yellow) is debated. Several highly selective P2X7R pharmacological blockers have been developed over the years, thus providing powerful tools for P2X7R studies. Biophysical properties and coupling to several different physiological responses make the P2X7R amenable to investigation by electrophysiology and cell biology techniques, which allow its identification and characterization in many different cell types and tissues. A careful description of the physiological features of the P2X7R is a prerequisite for an effective therapeutic development. Here we describe the most common techniques to asses P2X7R functions, including patch-clamp, intracellular calcium measurements, and membrane permeabilization to large fluorescent dyes in a selection of different cell types. In addition, we also describe common toxicity assays used to verify the effects of P2X7R stimulation on cell viability.
Collapse
|
6
|
Methods for single-cell recording and labeling in vivo. J Neurosci Methods 2019; 325:108354. [PMID: 31302156 DOI: 10.1016/j.jneumeth.2019.108354] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2019] [Revised: 07/07/2019] [Accepted: 07/07/2019] [Indexed: 01/29/2023]
Abstract
Targeting individual neurons in vivo is a key method to study the role of single cell types within local and brain-wide microcircuits. While novel technological developments now permit assessing activity from large number of cells simultaneously, there is currently no better solution than glass micropipettes to relate the physiology and morphology of single-cells. Sharp intracellular, juxtacellular, loose-patch and whole-cell approaches are some of the configurations used to record and label individual neurons. Here, we review procedures to establish successful electrophysiological recordings in vivo followed by appropriate labeling for post hoc morphological analysis. We provide operational recommendations for optimizing each configuration and a generic framework for functional, neurochemical and morphological identification of the different cell-types in a given region. Finally, we highlight emerging approaches that are challenging our current paradigms for single-cell recording and labeling in the living brain.
Collapse
|
7
|
Red Fluorescent Genetically Encoded Voltage Indicators with Millisecond Responsiveness. SENSORS (BASEL, SWITZERLAND) 2019; 19:E2982. [PMID: 31284557 PMCID: PMC6651345 DOI: 10.3390/s19132982] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/17/2019] [Revised: 07/02/2019] [Accepted: 07/04/2019] [Indexed: 01/09/2023]
Abstract
Genetically encoded fluorescent indicators typically consist of the sensitive and reporter protein domains connected with the amino acid linkers. The final performance of a particular indicator may depend on the linker length and composition as strong as it depends on the both domains nature. Here we aimed to optimize interdomain linkers in VSD-FR189-188-a recently described red fluorescent protein-based voltage indicator. We have tested 13 shortened linker versions and monitored the dynamic range, response speed and polarity of the corresponding voltage indicator variants. While the new indicators didn't show a contrast enhancement, some of them carrying very short interdomain linkers responded 25-fold faster than the parental VSD-FR189-188. Also we found the critical linker length at which fluorescence response to voltage shift changes its polarity from negative to positive slope. Our observations thus make an important contribution to the designing principles of the fluorescent protein-derived voltage indicators.
Collapse
|
8
|
From Bernstein's rheotome to Neher-Sakmann's patch electrode. The action potential. Physiol Rep 2019; 7:e13861. [PMID: 30604910 PMCID: PMC6316177 DOI: 10.14814/phy2.13861] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2018] [Revised: 07/10/2018] [Accepted: 07/28/2018] [Indexed: 01/08/2023] Open
Abstract
The aim of this review was to provide an overview of the most important stages in the development of cellular electrophysiology. The period covered starts with Bernstein's formulation of the membrane hypothesis and the measurement of the nerve and muscle action potential. Technical innovations make discoveries possible. This was the case with the use of the squid giant axon, allowing the insertion of "large" intracellular electrodes and derivation of transmembrane potentials. Application of the newly developed voltage clamp method for measuring ionic currents, resulted in the formulation of the ionic theory. At the same time transmembrane measurements were made possible in smaller cells by the introduction of the microelectrode. An improvement of this electrode was the next major (r)evolution. The patch electrode made it possible to descend to the molecular level and record single ionic channel activity. The patch technique has been proven to be exceptionally versatile. In its whole-cell configuration it was the solution to measure voltage clamp currents in small cells. See also: https://doi.org/10.14814/phy2.13860 & https://doi.org/10.14814/phy2.13862.
Collapse
|
9
|
Automatic spike sorting for high-density microelectrode arrays. J Neurophysiol 2018; 120:3155-3171. [PMID: 30207864 PMCID: PMC6314465 DOI: 10.1152/jn.00803.2017] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2017] [Revised: 09/07/2018] [Accepted: 09/07/2018] [Indexed: 11/22/2022] Open
Abstract
High-density microelectrode arrays can be used to record extracellular action potentials from hundreds to thousands of neurons simultaneously. Efficient spike sorters must be developed to cope with such large data volumes. Most existing spike sorting methods for single electrodes or small multielectrodes, however, suffer from the "curse of dimensionality" and cannot be directly applied to recordings with hundreds of electrodes. This holds particularly true for the standard reference spike sorting algorithm, principal component analysis-based feature extraction, followed by k-means or expectation maximization clustering, against which most spike sorters are evaluated. We present a spike sorting algorithm that circumvents the dimensionality problem by sorting local groups of electrodes independently with classical spike sorting approaches. It is scalable to any number of recording electrodes and well suited for parallel computing. The combination of data prewhitening before the principal component analysis-based extraction and a parameter-free clustering algorithm obviated the need for parameter adjustments. We evaluated its performance using surrogate data in which we systematically varied spike amplitudes and spike rates and that were generated by inserting template spikes into the voltage traces of real recordings. In a direct comparison, our algorithm could compete with existing state-of-the-art spike sorters in terms of sensitivity and precision, while parameter adjustment or manual cluster curation was not required. NEW & NOTEWORTHY We present an automatic spike sorting algorithm that combines three strategies to scale classical spike sorting techniques for high-density microelectrode arrays: 1) splitting the recording electrodes into small groups and sorting them independently; 2) clustering a subset of spikes and classifying the rest to limit computation time; and 3) prewhitening the spike waveforms to enable the use of parameter-free clustering. Finally, we combined these strategies into an automatic spike sorter that is competitive with state-of-the-art spike sorters.
Collapse
|
10
|
Abstract
Investigating mechanisms of general anesthesia requires access to multiple levels of neuronal function, from effects at individual synapses to responses in behaving animals. Drosophila melanogaster provides an excellent model to test different theories for general anesthesia because it offers robust methods for testing local as well as global target processes, in an animal that is similarly impacted by these diverse drugs as humans. Here, we outline methods to quantify two such endpoints, neurotransmission and behavioral responsiveness, focusing on the intravenous drug propofol.
Collapse
|
11
|
Abstract
Retinal first-order neurons, photoreceptors, receive visual inputs and convert them to neural signals. The second-order neurons, bipolar cells then sort out the visual signals and encode them through multiple neural streams. Approximately 15 morphological types of bipolar cells have been identified, which are thought to encode different aspects of visual signals such as motion and color (Ichinose et al. J Neurosci 34(26):8761-8771, 2014; Euler et al. Nat Rev Neurosci 15(8):507-519, 2014). To investigate functional aspects of OFF bipolar cells, single cell recordings are preferred; however, bipolar cells in the mouse retina are small and hard to distinguish from other types of cells. Here, we describe our methodology and tips for immunohistochemistry and patch clamp recordings for analyzing light-evoked responses in each type of OFF bipolar cell.
Collapse
|
12
|
Abstract
Melanopsin-expressing, intrinsically photosensitive retinal ganglion cells (ipRGCs) are a relatively recently discovered class of photoreceptor. ipRGCs can be subdivided into at least five subtypes (M1-M5), each of which has a distinct complement of morphological and physiological properties. ipRGC subtypes can be identified morphologically based on a combination of dendritic morphology and immunostaining for a cell-type specific marker. In this chapter, we describe methods for conclusively identifying each of the five ipRGC subtypes through a combination of patch clamp electrophysiology, Neurobiotin filling, visualization of ipRGC dendrites, and immunostaining for the marker SMI-32.
Collapse
|
13
|
High-throughput electrophysiological assays for voltage gated ion channels using SyncroPatch 768PE. PLoS One 2017; 12:e0180154. [PMID: 28683073 PMCID: PMC5500279 DOI: 10.1371/journal.pone.0180154] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2017] [Accepted: 06/09/2017] [Indexed: 01/08/2023] Open
Abstract
Ion channels regulate a variety of physiological processes and represent an important class of drug target. Among the many methods of studying ion channel function, patch clamp electrophysiology is considered the gold standard by providing the ultimate precision and flexibility. However, its utility in ion channel drug discovery is impeded by low throughput. Additionally, characterization of endogenous ion channels in primary cells remains technical challenging. In recent years, many automated patch clamp (APC) platforms have been developed to overcome these challenges, albeit with varying throughput, data quality and success rate. In this study, we utilized SyncroPatch 768PE, one of the latest generation APC platforms which conducts parallel recording from two-384 modules with giga-seal data quality, to push these 2 boundaries. By optimizing various cell patching parameters and a two-step voltage protocol, we developed a high throughput APC assay for the voltage-gated sodium channel Nav1.7. By testing a group of Nav1.7 reference compounds’ IC50, this assay was proved to be highly consistent with manual patch clamp (R > 0.9). In a pilot screening of 10,000 compounds, the success rate, defined by > 500 MΩ seal resistance and >500 pA peak current, was 79%. The assay was robust with daily throughput ~ 6,000 data points and Z’ factor 0.72. Using the same platform, we also successfully recorded endogenous voltage-gated potassium channel Kv1.3 in primary T cells. Together, our data suggest that SyncroPatch 768PE provides a powerful platform for ion channel research and drug discovery.
Collapse
|
14
|
Abstract
Soon after the glass micropipette was invented as a micro-tool for manipulation of single bacteria and the microinjection and microsurgery of living cells, it was seen to hold promise as a microelectrode to stimulate individual cells electrically and to study electrical potentials in them. Initial successes and accurate mechanistic explanations of the results were achieved in giant plant cells in the 1920s. Long known surface electrical activity in nerves and muscles was only resolved at a similar cellular level in the 1930s and 1940s after the discovery of giant nerve fibers and the development of finer tipped microelectrodes for normal-sized cells.
Collapse
|
15
|
Angular Approach Scanning Ion Conductance Microscopy. Biophys J 2016; 110:2252-65. [PMID: 27224490 PMCID: PMC4880884 DOI: 10.1016/j.bpj.2016.04.017] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2015] [Revised: 04/14/2016] [Accepted: 04/15/2016] [Indexed: 11/16/2022] Open
Abstract
Scanning ion conductance microscopy (SICM) is a super-resolution live imaging technique that uses a glass nanopipette as an imaging probe to produce three-dimensional (3D) images of cell surface. SICM can be used to analyze cell morphology at nanoscale, follow membrane dynamics, precisely position an imaging nanopipette close to a structure of interest, and use it to obtain ion channel recordings or locally apply stimuli or drugs. Practical implementations of these SICM advantages, however, are often complicated due to the limitations of currently available SICM systems that inherited their design from other scanning probe microscopes in which the scan assembly is placed right above the specimen. Such arrangement makes the setting of optimal illumination necessary for phase contrast or the use of high magnification upright optics difficult. Here, we describe the designs that allow mounting SICM scan head on a standard patch-clamp micromanipulator and imaging the sample at an adjustable approach angle. This angle could be as shallow as the approach angle of a patch-clamp pipette between a water immersion objective and the specimen. Using this angular approach SICM, we obtained topographical images of cells grown on nontransparent nanoneedle arrays, of islets of Langerhans, and of hippocampal neurons under upright optical microscope. We also imaged previously inaccessible areas of cells such as the side surfaces of the hair cell stereocilia and the intercalated disks of isolated cardiac myocytes, and performed targeted patch-clamp recordings from the latter. Thus, our new, to our knowledge, angular approach SICM allows imaging of living cells on nontransparent substrates and a seamless integration with most patch-clamp setups on either inverted or upright microscopes, which would facilitate research in cell biophysics and physiology.
Collapse
|
16
|
Enhanced Monitoring of Nanosecond Electric Pulse-Evoked Membrane Conductance Changes in Whole-Cell Patch Clamp Experiments. J Membr Biol 2016; 249:633-644. [PMID: 27075358 DOI: 10.1007/s00232-016-9902-5] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2016] [Accepted: 04/06/2016] [Indexed: 01/23/2023]
Abstract
Patch clamp electrophysiology serves as a powerful method for studying changes in plasma membrane ion conductance induced by externally applied high-intensity nanosecond electric pulses (NEPs). This paper describes an enhanced monitoring technique that minimizes the length of time between pulse exposure and data recording in a patch-clamped excitable cell. Whole-cell membrane currents were continuously recorded up to 11 ms before and resumed 8 ms after delivery of a 5-ns, 6 MV/m pulse by a pair of tungsten rod electrodes to a patched adrenal chromaffin cell maintained at a holding potential of -70 mV. This timing was achieved by two sets of relay switches. One set was used to disconnect the patch pipette electrode from the pre-amplifier and connect it to a battery to maintain membrane potential at -70 mV, and also to disconnect the reference electrode from the amplifier. The other set was used to disconnect the electrodes from the pulse generator until the time of NEP/sham exposure. The sequence and timing of both sets of relays were computer-controlled. Using this procedure, we observed that a 5-ns pulse induced an instantaneous inward current that decayed exponentially over the course of several minutes, that a second pulse induced a similar response, and that the current was carried, at least in part, by Na+. This approach for characterizing ion conductance changes in an excitable cell in response to NEPs will yield information essential for assessing the potential use of NEP stimulation for therapeutic applications.
Collapse
|
17
|
Abstract
Hair cells are designed to sense mechanical stimuli of sound using their apical stereocilia hair bundles. Mechanical deflection of this hair bundle is converted into an electrical signal through gating of mechano-electric transduction channels. Stiff probe stimulation of hair bundles is an invaluable tool for studying the transduction channel and its associated processes because of the speed and ability to precisely control hair bundle position. Proper construction of these devices is critical to their ultimate performance as is appropriate placement of the probe onto the hair bundle. Here we describe the construction and use of a glass probe coupled to a piezo-electric actuator for stimulating hair bundles, including the basic technique for positioning of the stimulating probe onto the hair bundle. These piezo-electric stimulators can be adapted to other mechanically sensitive systems.
Collapse
|
18
|
Establishment of the Dual Whole Cell Recording Patch Clamp Configuration for the Measurement of Gap Junction Conductance. Methods Mol Biol 2016; 1437:213-231. [PMID: 27207298 DOI: 10.1007/978-1-4939-3664-9_16] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
The development of the patch clamp technique has enabled investigators to directly measure gap junction conductance between isolated pairs of small cells with resolution to the single channel level. The dual patch clamp recording technique requires specialized equipment and the acquired skill to reliably establish gigaohm seals and the whole cell recording configuration with high efficiency. This chapter describes the equipment needed and methods required to achieve accurate measurement of macroscopic and single gap junction channel conductances. Inherent limitations with the dual whole cell recording technique and methods to correct for series access resistance errors are defined as well as basic procedures to determine the essential electrical parameters necessary to evaluate the accuracy of gap junction conductance measurements using this approach.
Collapse
|
19
|
MATLAB-based automated patch-clamp system for awake behaving mice. J Neurophysiol 2015; 114:1331-45. [PMID: 26084901 PMCID: PMC4725114 DOI: 10.1152/jn.00025.2015] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2015] [Accepted: 06/14/2015] [Indexed: 11/22/2022] Open
Abstract
Automation has been an important part of biomedical research for decades, and the use of automated and robotic systems is now standard for such tasks as DNA sequencing, microfluidics, and high-throughput screening. Recently, Kodandaramaiah and colleagues (Nat Methods 9: 585-587, 2012) demonstrated, using anesthetized animals, the feasibility of automating blind patch-clamp recordings in vivo. Blind patch is a good target for automation because it is a complex yet highly stereotyped process that revolves around analysis of a single signal (electrode impedance) and movement along a single axis. Here, we introduce an automated system for blind patch-clamp recordings from awake, head-fixed mice running on a wheel. In its design, we were guided by 3 requirements: easy-to-use and easy-to-modify software; seamless integration of behavioral equipment; and efficient use of time. The resulting system employs equipment that is standard for patch recording rigs, moderately priced, or simple to make. It is written entirely in MATLAB, a programming environment that has an enormous user base in the neuroscience community and many available resources for analysis and instrument control. Using this system, we obtained 19 whole cell patch recordings from neurons in the prefrontal cortex of awake mice, aged 8-9 wk. Successful recordings had series resistances that averaged 52 ± 4 MΩ and required 5.7 ± 0.6 attempts to obtain. These numbers are comparable with those of experienced electrophysiologists working manually, and this system, written in a simple and familiar language, will be useful to many cellular electrophysiologists who wish to study awake behaving mice.
Collapse
|
20
|
Dynamics of T-Junction Solution Switching Aimed at Patch Clamp Experiments. PLoS One 2015; 10:e0133187. [PMID: 26177538 PMCID: PMC4503516 DOI: 10.1371/journal.pone.0133187] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2014] [Accepted: 06/23/2015] [Indexed: 11/29/2022] Open
Abstract
Solutions exchange systems are responsible for the timing of drug application on patch clamp experiments. There are two basic strategies for generating a solution exchange. When slow exchanges are bearable, it is easier to perform the exchange inside the tubing system upstream of the exit port. On the other hand, fast, reproducible, exchanges are usually performed downstream of the exit port. As both strategies are combinable, increasing the performance of upstream exchanges is desirable. We designed a simple method for manufacturing T-junctions (300 μm I.D.) and we measured the time profile of exchange of two saline solutions using a patch pipette with an open tip. Three factors were found to determine the timing of the solution switching: pressure, travelled distance and off-center distance. A linear relationship between the time delay and the travelled distance was found for each tested pressure, showing its dependence to the fluid velocity, which increased with pressure. The exchange time was found to increase quadratically with the delay, although a sizeable variability remains unexplained by this relationship. The delay and exchange times increased as the recording pipette moved away from the center of the stream. Those increases became dramatic as the pipette was moved close to the stream borders. Mass transport along the travelled distance between the slow fluid at the border and the fast fluid at the center seems to contribute to the time course of the solution exchange. This effect would be present in all tubing based devices. Present results might be of fundamental importance for the adequate design of serial compound exchangers which would be instrumental in the discovery of drugs that modulate the action of the physiological agonists of ion channels with the purpose of fine tuning their physiology.
Collapse
|
21
|
Abstract
From its invention in the 1970s, the patch clamp technique is the gold standard in electrophysiology research and drug screening because it is the only tool enabling accurate investigation of voltage-gated ion channels, which are responsible for action potentials. Because of its key role in drug screening, innovation efforts are being made to reduce its complexity toward more automated systems. While some of these new approaches are being adopted in pharmaceutical companies, conventional patch-clamp remains unmatched in fundamental research due to its versatility. Here, we merged the patch clamp and atomic force microscope (AFM) techniques, thus equipping the patch-clamp with the sensitive AFM force control. This was possible using the FluidFM, a force-controlled nanopipette based on microchanneled AFM cantilevers. First, the compatibility of the system with patch-clamp electronics and its ability to record the activity of voltage-gated ion channels in whole-cell configuration was demonstrated with sodium (NaV1.5) channels. Second, we showed the feasibility of simultaneous recording of membrane current and force development during contraction of isolated cardiomyocytes. Force feedback allowed for a gentle and stable contact between AFM tip and cell membrane enabling serial patch clamping and injection without apparent cell damage.
Collapse
|
22
|
Quantum dot-based multiphoton fluorescent pipettes for targeted neuronal electrophysiology. Nat Methods 2014; 11:1237-1241. [PMID: 25326662 PMCID: PMC4245189 DOI: 10.1038/nmeth.3146] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2014] [Accepted: 08/22/2014] [Indexed: 11/09/2022]
Abstract
Targeting visually identified neurons for electrophysiological recording is a fundamental neuroscience technique; however, its potential is hampered by poor visualization of pipette tips in deep brain tissue. We describe quantum dot-coated glass pipettes that provide strong two-photon contrast at deeper penetration depths than those achievable with current methods. We demonstrated the pipettes' utility in targeted patch-clamp recording experiments and single-cell electroporation of identified rat and mouse neurons in vitro and in vivo.
Collapse
|
23
|
Gigaseal mechanics: creep of the gigaseal under the action of pressure, adhesion, and voltage. J Phys Chem B 2014; 118:12660-72. [PMID: 25295693 PMCID: PMC4226309 DOI: 10.1021/jp506965v] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2014] [Revised: 10/06/2014] [Indexed: 11/28/2022]
Abstract
Patch clamping depends on a tight seal between the cell membrane and the glass of the pipet. Why does the seal have such high electric resistance? Why does the patch adhere so strongly to the glass? Even under the action of strong hydrostatic, adhesion, and electrical forces, it creeps at a very low velocity. To explore possible explanations, we examined two physical models for the structure of the seal zone and the adhesion forces and two respective mechanisms of patch creep and electric conductivity. There is saline between the membrane and glass in the seal, and the flow of this solution under hydrostatic pressure or electroosmosis should drag a patch. There is a second possibility: the lipid core of the membrane is liquid and should be able to flow, with the inner monolayer slipping over the outer one. Both mechanisms predict the creep velocity as a function of the properties of the seal and the membrane, the pipet geometry, and the driving force. These model predictions are compared with experimental data for azolectin liposomes with added cholesterol or proteins. It turns out that to obtain experimentally observed creep velocities, a simple viscous flow in the seal zone requires ~10 Pa·s viscosity; it is unclear what structure might provide that because that viscosity alone severely constrains the electric resistance of the gigaseal. Possibly, it is the fluid bilayer that allows the motion. The two models provide an estimate of the adhesion energy of the membrane to the glass and membrane's electric characteristics through the comparison between the velocities of pressure-, adhesion-, and voltage-driven creep.
Collapse
|
24
|
The use of three-dimensional printing to produce in vitro slice chambers. J Neurosci Methods 2014; 238:82-7. [PMID: 25251556 DOI: 10.1016/j.jneumeth.2014.09.012] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2014] [Revised: 09/02/2014] [Accepted: 09/12/2014] [Indexed: 11/30/2022]
Abstract
BACKGROUND In recent years, 3D printing technology has become inexpensive and simple enough that any lab can own and use one of these printers. NEW METHOD We explored the potential use of 3D printers for quickly and easily producing in vitro slice chambers for patch clamp electrophysiology. Slice chambers were produced using five available plastics: ABS, PLA, Nylon 618, Nylon 680, and T-glase. These "lab-made" chambers were also made using stereolithography through a professional printing service (Shapeways). This study measured intrinsic membrane properties of neurons in the brain stem pedunculopontine nucleus (PPN) and layer V pyramidal neurons in retrosplenial cortex. RESULTS Nylon 680 and T-glase significantly hyperpolarized PPN neurons. ABS increased input resistance, decreased action potential amplitude, and increased firing frequency in pyramidal cortical neurons. To test long term exposure to each plastic, human neuroblastoma SHSY5Y cell cultures were exposed to each plastic for 1 week. ABS decreased cell counts while Nylon 618 and Shapeways plastics eliminated cells. Primary mouse pituitary cultures were also tested for 24-h exposure. ABS decreased cell counts while Nylon 618 and Shapeways plastics dramatically decreased cell counts. COMPARISON TO EXISTING METHODS Chambers can be quickly and inexpensively printed in the lab. ABS, PLA, Nylon 680, and T-glase plastics would suffice for many experiments instead of commercially produced slice chambers. CONCLUSIONS While these technologies are still in their infancy, they represent a powerful addition to the lab environment. With careful selection of print material, slice chambers can be quickly and inexpensively manufactured in the lab.
Collapse
|
25
|
Abstract
While high-throughput planar patch-clamp instruments are now established to perform whole-cell recordings for drug screening, the conventional micropipette-based approach remains the gold standard for performing cell-attached single-channel recordings. Generally, planar platforms are not well-suited for such studies due to excess noise resulting from low seal resistances and the use of substrates with poor dielectric properties. Since these platforms tend to use the same pore to position a cell by suction and establish a seal, biological debris from the cell suspension can contaminate the pore surface prior to seal formation, reducing the seal resistance. Here, femtosecond laser ablation was used to fabricate dual-pore glass chips optimized for use in cell-attached single-channel recordings that circumvent this problem by using different pores to position a cell and to establish a seal. This dual-pore design also permitted the use of a relatively small patch aperture (D ~ 150 to 300 nm) that is better-suited for establishing high-resistance seals than the micropores used typically in planar patch-clamp setups (D ~ 1 to 2 μm) without compromising the ability of the device to position a cell. Taking advantage of the high seal resistances and low capacitive and dielectric noise realized using glass substrates, patch-clamp experiments with these dual-pore chips consistently achieved high seal resistances (rate of gigaseal formation = 61%, mean seal resistance = 53 GΩ), maintained gigaseals for prolonged durations (up to 6 hours), achieved RMS noise values as low as 0.46 pA at 5 kHz bandwidth, and enabled single-channel recordings in the cell-attached configuration that are comparable to those obtained by conventional patch-clamp.
Collapse
|
26
|
Abstract
Control of membrane voltage and membrane current measurements are of critical importance for the study of numerous aspects of skeletal muscle physiology and pathophysiology. The silicone-clamp technique makes use of a conventional patch-clamp apparatus to achieve whole-cell voltage clamp of a restricted portion of a fully differentiated adult skeletal muscle fiber. The major part of an isolated muscle fiber is insulated from the extracellular medium with silicone grease and the tip of a single microelectrode connected to the amplifier is then inserted within the fiber through the silicone layer. The method is extremely easy to implement. It represents an alternative to the traditional vaseline-gap isolation and two or three microelectrodes voltage-clamp techniques. The present chapter reviews the benefits of the silicone-clamp technique and provides updated detailed insights into its practical implementation.
Collapse
|
27
|
Abstract
Today, the patch-clamp technique is the main technique in electrophysiology to record action potentials or membrane current from isolated cells, using a patch pipette to gain electrical access to the cell. The common recording modes of the patch-clamp technique are current clamp and voltage clamp. In the current clamp mode, the current injected through the patch pipette is under control while the free-running membrane potential of the cell is recorded. Current clamp allows for measurements of action potentials that may either occur spontaneously or in response to an injected stimulus current. In voltage clamp mode, the membrane potential is held at a set level through a feedback circuit, which allows for the recording of the net membrane current at a given membrane potential.A less common configuration of the patch-clamp technique is the dynamic clamp. In this configuration, a specific non-predetermined membrane current can be added to or removed from the cell while it is in free-running current clamp mode. This current may be computed in real time, based on the recorded action potential of the cell, and injected into the cell. Instead of being computed, this current may also be recorded from a heterologous expression system such as a HEK-293 cell that is voltage-clamped by the free-running action potential of the cell ("dynamic action potential clamp"). Thus, one may directly test the effects of an additional or mutated membrane current, a synaptic current or a gap junctional current on the action potential of a patch-clamped cell. In the present chapter, we describe the dynamic clamp on the basis of its application in cardiac cellular electrophysiology.
Collapse
|
28
|
Abstract
As the main input nucleus to the basal ganglia, the striatum is responsible for receiving and integrating highly convergent afferents to ultimately guide action selection and movement initiation. Although the majority of this synaptic integration occurs in the dendrites of striatal projection neurons (SPNs), their thin diameter makes them inaccessible with traditional recording electrodes. Recent advances in optical imaging technologies have allowed us and others to start lifting the veil on the mechanisms governing synaptic integration in the striatum by enabling direct dendritic measurements and manipulations. Here we describe how our lab has approached combining 2-photon imaging and photolysis with electrophysiological recordings to study dendritic excitability and synaptic integration in the striatum.
Collapse
|
29
|
Abstract
The patch-clamp technique and the whole-cell measurements derived from it have greatly advanced our understanding of the coding properties of individual neurons by allowing for a detailed analysis of their excitatory/inhibitory synaptic inputs, intrinsic electrical properties, and morphology. Because such measurements require a high level of mechanical stability they have for a long time been limited to in vitro and anesthetized preparations. Recently, however, a considerable amount of effort has been devoted to extending these techniques to awake restrained/head-fixed preparations allowing for the study of the input-output functions of neurons during behavior. In this chapter we describe a technique extending patch-clamp recordings to awake animals free to explore their environments.
Collapse
|
30
|
Abstract
We provide a historic outlook on the development of the concept of bioelectricity, with emphasis on the neuromuscular junction as a model that revolutionized our thinking of the nerve, nervous, and muscle tissue excitability. We abridge some crucial experiments in defining the electrical excitability of biological cells. We also provide an insight into developments of tools and methods, which gradually yielded a contemporary "palette" of electrophysiology approaches, including the patch clamp. Pioneering steps in this journey, ranging from Galvani's experiments using the Leyden jar to those of Neher and Sakmann using a gigaseal patch-clamp approach, are pictorially illustrated. This chapter is meant to be a perspective to the following sections in this volume dedicated to patch-clamp methods and protocols.
Collapse
|
31
|
State-of-the-art automated patch clamp: heat activation, action potentials, and high throughput in ion channel screening. Methods Mol Biol 2014; 1183:65-80. [PMID: 25023302 DOI: 10.1007/978-1-4939-1096-0_4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
A successful robotic approach of the patch clamp technique is based on planar patch clamp chips where a glass pipette, as used in conventional patch clamping, is replaced by a thin planar glass sheet with a small hole in the middle. Automated patch clamp (APC) systems utilizing this chip design offer higher throughput capabilities and ease of use and thus have become common in basic research, drug development, and safety screening. Further development of existing devices and introduction of new systems widen the range of possible experiments and increase throughput. Here, two features with different areas of applications that meet the needs of drug discovery researchers and basic researchers alike are described. The utilized system is a medium throughput APC device capable of recording up to eight cells simultaneously. The temperature control capability and the possibility to perform recordings not only in the voltage clamp but also in the current clamp mode are described in detail. Since eight recordings can be generated in parallel without compromising data quality, reliable and cost-effective and time-effective screening of compounds against ion channels using voltage clamp and current clamp electrophysiology can be performed.
Collapse
|
32
|
Abstract
The patch-clamp technique is generally accepted as the gold standard for studying ion channel activity allowing investigators to either "clamp" membrane voltage and directly measure transmembrane currents through ion channels, or to passively monitor spontaneously occurring intracellular voltage oscillations. However, this resulting high information content comes at a price. The technique is labor-intensive and requires highly trained personnel and expensive equipment. This seriously limits its application as an interrogation tool for drug development. Patch-clamp chips have been developed in the last decade to overcome the tedious manipulations associated with the use of glass pipettes in conventional patch-clamp experiments. In this chapter, we describe some of the main materials and fabrication protocols that have been developed to date for the production of patch-clamp chips. We also present the concept of a patch-clamp chip array providing high resolution patch-clamp recordings from individual cells at multiple sites in a network of communicating neurons. On this chip, the neurons are aligned with the aperture-probes using chemical patterning. In the discussion we review the potential use of this technology for pharmaceutical assays, neuronal physiology and synaptic plasticity studies.
Collapse
|
33
|
A patch-clamp ASIC for nanopore-based DNA analysis. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2013; 7:285-295. [PMID: 23853328 DOI: 10.1109/tbcas.2012.2200893] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
In this paper, a fully integrated high-sensitivity patch-clamp system is proposed for single-molecule deoxyribonucleic acid (DNA) analysis using a nanopore sensor. This system is composed of two main blocks for amplification and compensation. The amplification block is composed of three stages: 1) a headstage, 2) a voltage-gain difference amplifier, and 3) a track-and-hold circuit, that amplify a minute ionic current variation sensed by the nanopore while the compensation block avoids the headstage saturation caused by the input parasitic capacitances during sensing. By employing design techniques novel for this application, such as an instrumentation--amplifier topology and a compensation switch, we minimize the deleterious effects of the input-offset voltage and the input parasitic capacitances while attaining hardware simplicity. This system is fabricated in a 0.35 μm 4M2P CMOS process and is demonstrated using an α-hemolysin protein nanopore for detection of individual molecules of single-stranded DNA that pass through the 1.5 nm-diameter pore. In future work, the refined system will functionalize single and multiple solid-state nanopores formed in integrated microfluidic devices for advanced DNA analysis, in scientific and diagnostic applications.
Collapse
|
34
|
Abstract
Mechanotransduction, the conversion of a mechanical stimulus into a biological response, constitutes the basis of a variety of physiological functions such as the senses of touch, balance, proprioception, blood pressure, and hearing. In vertebrates, mechanosensation is mediated by mechanosensory neurons, whose cell bodies are located in trigeminal and dorsal root ganglia. Here, we describe an in vitro model of mechanotransduction that provides an opportunity to explore the properties of mechanosensitive channels in mammalian sensory neurons. The mechano-clamp method allows applying local force on plasma membrane of whole-cell patch-clamped sensory neurons. This technique uses a mechanical probe driven by a computer-assisted piezoelectric microstage to repeatedly stimulate sensory neurons with accurate control of stimulus strength, duration, and speed.
Collapse
|
35
|
Abstract
Ion channels are integral membrane proteins that regulate the flow of ions across the plasma membrane and the membranes of intracellular organelles of both excitable and non-excitable cells. Ion channels are vital to a wide variety of biological processes and are prominent components of the nervous system and cardiovascular system, as well as controlling many metabolic functions. Furthermore, ion channels are known to be involved in many disease states and as such have become popular therapeutic targets. For many years now manual patch-clamping has been regarded as one of the best approaches for assaying ion channel function, through direct measurement of ion flow across these membrane proteins. Over the last decade there have been many remarkable breakthroughs in the development of technologies enabling the study of ion channels. One of these breakthroughs is the development of automated planar patch-clamp technology. Automated platforms have demonstrated the ability to generate high-quality data with high throughput capabilities, at great efficiency and reliability. Additional features such as simultaneous intracellular and extracellular perfusion of the cell membrane, current clamp operation, fast compound application, an increasing rate of parallelization, and more recently temperature control have been introduced. Furthermore, in addition to the well-established studies of over-expressed ion channel proteins in cell lines, new generations of planar patch-clamp systems have enabled successful studies of native and primary mammalian cells. This technology is becoming increasingly popular and extensively used both within areas of drug discovery as well as academic research. Many platforms have been developed including NPC-16 Patchliner(®) and SyncroPatch(®) 96 (Nanion Technologies GmbH, Munich), CytoPatch™ (Cytocentrics AG, Rostock), PatchXpress(®) 7000A, IonWorks(®) Quattro and IonWorks Barracuda™, (Molecular Devices, LLC); Dynaflow(®) HT (Cellectricon AB, Mölndal), QPatch HT (Sophion A/S, Copenhagen), IonFlux HT (Fluxion Bioscience Inc, USA), which have demonstrated the capability to generate recordings similar in quality to that of conventional patch clamping. Here we describe features of Nanion's NPC-16 Patchliner(®) and processes and protocols suited for this particularly flexible and successful high-throughput automated platform, which is based on planar patch-clamp technology. However, many of the protocols and notes given in this chapter can be applied to other automated patch-clamp platforms, similarly.
Collapse
|
36
|
Recording dendritic ion channel properties and function from cortical neurons. Methods Mol Biol 2013; 998:303-309. [PMID: 23529440 DOI: 10.1007/978-1-62703-351-0_24] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
Dendrites emerging from the cell bodies of neurons receive the majority of synaptic inputs. They possess a plethora of ion channels that are essential for the processing of these synaptic signals. To fully understand how dendritic ion channels influence neuronal information processing, various patch-clamp techniques that allow electrophysiological recordings to be made directly from dendrites have been developed. In this chapter, I describe one such method that is suitable for making electrophysiological recordings from the apical dendrites of hippocampal and cortical pyramidal neurons.
Collapse
|
37
|
Abstract
Two-electrode voltage clamp (TEVC) is a conventional electrophysiological technique used to artificially control the membrane potential (V m) of large cells to study the properties of electrogenic membrane proteins, especially ion channels. It makes use of two intracellular electrodes-a voltage electrode as V m sensor and a current electrode for current injection to adjust the V m, thus setting the membrane potential at desired values and recording the membrane current to analyze ion channel activities. Here we describe the use of TEVC in combination with exogenous mRNA expression in Xenopus oocytes for ion channel recording.
Collapse
|
38
|
Evaluation of diel patterns of relative changes in cell turgor of tomato plants using leaf patch clamp pressure probes. PHYSIOLOGIA PLANTARUM 2012; 146:439-447. [PMID: 22540231 DOI: 10.1111/j.1399-3054.2012.01637.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Relative changes in cell turgor of leaves of well-watered tomato plants were evaluated using the leaf patch clamp pressure probe (LPCP) under dynamic greenhouse climate conditions. LPCP changes, a measure for relative changes in cell turgor, were monitored at three different heights of transpiring and non-transpiring leaves of tomato plants on sunny and cloudy days simultaneously with whole plant water uptake. Clear diel patterns were observed for relative changes of cell turgor of both transpiring and non-transpiring leaves, which were stronger on sunny days than on cloudy days. A clear effect of canopy height was also observed. Non-transpiring leaves showed relative changes in cell turgor that closely followed plant water uptake throughout the day. However, in the afternoon the relative changes of cell turgor of the transpiring leaves displayed a delayed response in comparison to plant water uptake. Subsequent recovery of cell turgor loss of transpiring leaves during the following night appeared insufficient, as the pre-dawn turgescent state similar to the previous night was not attained.
Collapse
|
39
|
Voltage-sensitive dye recording from axons, dendrites and dendritic spines of individual neurons in brain slices. J Vis Exp 2012:e4261. [PMID: 23222505 PMCID: PMC3565854 DOI: 10.3791/4261] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022] Open
Abstract
Understanding the biophysical properties and functional organization of single neurons and how they process information is fundamental for understanding how the brain works. The primary function of any nerve cell is to process electrical signals, usually from multiple sources. Electrical properties of neuronal processes are extraordinarily complex, dynamic, and, in the general case, impossible to predict in the absence of detailed measurements. To obtain such a measurement one would, ideally, like to be able to monitor, at multiple sites, subthreshold events as they travel from the sites of origin on neuronal processes and summate at particular locations to influence action potential initiation. This goal has not been achieved in any neuron due to technical limitations of measurements that employ electrodes. To overcome this drawback, it is highly desirable to complement the patch-electrode approach with imaging techniques that permit extensive parallel recordings from all parts of a neuron. Here, we describe such a technique - optical recording of membrane potential transients with organic voltage-sensitive dyes (V(m)-imaging) - characterized by sub-millisecond and sub-micrometer resolution. Our method is based on pioneering work on voltage-sensitive molecular probes (2). Many aspects of the initial technology have been continuously improved over several decades (3, 5, 11). Additionally, previous work documented two essential characteristics of V(m)-imaging. Firstly, fluorescence signals are linearly proportional to membrane potential over the entire physiological range (-100 mV to +100 mV; (10, 14, 16)). Secondly, loading neurons with the voltage-sensitive dye used here (JPW 3028) does not have detectable pharmacological effects. The recorded broadening of the spike during dye loading is completely reversible (4, 7). Additionally, experimental evidence shows that it is possible to obtain a significant number (up to hundreds) of recordings prior to any detectable phototoxic effects (4, 6, 12, 13). At present, we take advantage of the superb brightness and stability of a laser light source at near-optimal wavelength to maximize the sensitivity of the V(m)-imaging technique. The current sensitivity permits multiple site optical recordings of V(m) transients from all parts of a neuron, including axons and axon collaterals, terminal dendritic branches, and individual dendritic spines. The acquired information on signal interactions can be analyzed quantitatively as well as directly visualized in the form of a movie.
Collapse
|
40
|
An integrated field-effect microdevice for monitoring membrane transport in Xenopus laevis oocytes via lateral proton diffusion. PLoS One 2012; 7:e39238. [PMID: 22792166 PMCID: PMC3390327 DOI: 10.1371/journal.pone.0039238] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2012] [Accepted: 05/17/2012] [Indexed: 11/18/2022] Open
Abstract
An integrated microdevice for measuring proton-dependent membrane activity at the surface of Xenopus laevis oocytes is presented. By establishing a stable contact between the oocyte vitelline membrane and an ion-sensitive field-effect (ISFET) sensor inside a microperfusion channel, changes in surface pH that are hypothesized to result from facilitated proton lateral diffusion along the membrane were detected. The solute diffusion barrier created between the sensor and the active membrane area allowed detection of surface proton concentration free from interference of solutes in bulk solution. The proposed sensor mechanism was verified by heterologously expressing membrane transport proteins and recording changes in surface pH during application of the specific substrates. Experiments conducted on two families of phosphate-sodium cotransporters (SLC20 & SLC34) demonstrated that it is possible to detect phosphate transport for both electrogenic and electroneutral isoforms and distinguish between transport of different phosphate species. Furthermore, the transport activity of the proton/amino acid cotransporter PAT1 assayed using conventional whole cell electrophysiology correlated well with changes in surface pH, confirming the ability of the system to detect activity proportional to expression level.
Collapse
|
41
|
Action potentials recorded from bundles of very thin, gray matter axons in rat cerebellar slices using a grease-gap method. J Neurosci Methods 2012; 208:119-27. [PMID: 22579878 DOI: 10.1016/j.jneumeth.2012.05.005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2012] [Revised: 04/30/2012] [Accepted: 05/01/2012] [Indexed: 11/18/2022]
Abstract
We investigated the ability of a grease-gap method to record fast and slow changes of the membrane potential from bundles of gray matter axons. Their membrane potentials are of particular interest because these axons are different from most axons that have been investigated using intra-axonal or gap techniques. One of the main differences is that gray matter axons typically have closely spaced presynaptic specializations, called boutons or varicosities, distributed along their entire paths. In response to electrical activation of bundles of parallel fiber axons we were able to record small (128-416μV) but stable signals that we show most likely represented a fraction of the trans-membrane action potentials. A less-than 100% fraction prevents measurements of absolute values for membrane potentials, but the good signal-to-noise ratio (typically 10-16) allows detection of changes in resting membrane potential, action potentials and their after-potentials. Because very little is known about the shape of action potentials and after-potentials in these axons we used several independent methods to make it likely that the grease-gap signal was of intra-axonal origin. We demonstrate the utility of the method by showing that the action potentials in cerebellar parallel fibers and hippocampal Schaffer collaterals had a slowly decaying, depolarized after-potential. The method is ideal for pharmacological tests, which we demonstrate by showing that the slow after-potential was sensitive to 4-AP, and that the membrane potential was reduced by 200μM Ba(2+).
Collapse
|
42
|
Vertical nanowire electrode arrays as a scalable platform for intracellular interfacing to neuronal circuits. NATURE NANOTECHNOLOGY 2012; 7:180-4. [PMID: 22231664 PMCID: PMC4209482 DOI: 10.1038/nnano.2011.249] [Citation(s) in RCA: 357] [Impact Index Per Article: 29.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/09/2011] [Accepted: 12/07/2011] [Indexed: 05/18/2023]
Abstract
Deciphering the neuronal code--the rules by which neuronal circuits store and process information--is a major scientific challenge. Currently, these efforts are impeded by a lack of experimental tools that are sensitive enough to quantify the strength of individual synaptic connections and also scalable enough to simultaneously measure and control a large number of mammalian neurons with single-cell resolution. Here, we report a scalable intracellular electrode platform based on vertical nanowires that allows parallel electrical interfacing to multiple mammalian neurons. Specifically, we show that our vertical nanowire electrode arrays can intracellularly record and stimulate neuronal activity in dissociated cultures of rat cortical neurons and can also be used to map multiple individual synaptic connections. The scalability of this platform, combined with its compatibility with silicon nanofabrication techniques, provides a clear path towards simultaneous, high-fidelity interfacing with hundreds of individual neurons.
Collapse
|
43
|
Mechanical actuation of ion channels using a piezoelectric planar patch clamp system. LAB ON A CHIP 2012; 12:80-87. [PMID: 22015778 DOI: 10.1039/c1lc20636b] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
High-throughput screening of ion channels is now possible with the advent of the planar patch clamp system. This system drastically increases the number of ion channels that can be studied, as multiple ion channel experiments can now be conducted in parallel. However, due to tedious, usually pressure-driven mechanotransduction techniques, there has been a slow integration of this technology into the field of mechanosensitive ion channels. By implementing a piezoelectric quartz substrate into a planar patch clamp system, we show that the patch clamp substrate itself can be used to mechanically actuate ion channels. The piezoelectric substrate transduces an external, applied electric field into a mechanical tension, so precise actuation of the membrane can be accomplished. By applying this electric field only to the outer edges of the substrate, no ulterior electric field is created in the vicinity of the membrane during actuation. Further, with resonant frequencies ranging from 1 kHz to 200 MHz, quartz substrates can be used to apply a wide range of time-varying tensions to cell membranes. This will allow for new and instructive investigations into the dynamic mechanotransductive properties of ion channels.
Collapse
|
44
|
A pressure-polishing set-up to fabricate patch pipettes that seal on virtually any membrane, yielding low access resistance and efficient intracellular perfusion. EUROPEAN BIOPHYSICS JOURNAL: EBJ 2011; 40:1215-23. [PMID: 21761372 DOI: 10.1007/s00249-011-0727-y] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/27/2011] [Revised: 06/15/2011] [Accepted: 06/22/2011] [Indexed: 11/26/2022]
Abstract
When performing whole-cell configuration recordings, it is important to minimize series resistance to reduce the time constant of charging the cell membrane capacitance and to reduce error in membrane potential control. To this end, an existing method was improved by widening the patch pipette shank through the calibrated combination of heat and air pressure. The heat was produced by passing current through a filament that was shaped appropriately to ensure a homogeneous heating of the pipette shank. Pressurized air was applied to the lumen of a pipette, pulled from a borosilicate glass microcap, via the pressure port of a modified commercial holder. The pipette reshaping was viewed on an LCD monitor connected to a contrast-intensified CCD camera and coupled to a modified bright-field stereomicroscope. By appropriately regulating the timing of air pressure and the application of heating, the pipette shank and, independently, the tip opening diameter were widened as desired. The methods illustrated here to fabricate and use the patch pipettes, using just one glass type, allowed the sealing of a wide variety of cell types isolated from different amphibian, reptilian, fish, and mammalian tissues as well as a variety of artificial membranes made with many different lipid mixtures. The access resistance yielded by pressure-polished pipettes was approximately one-fourth the size of the one attained with conventional pipettes; besides improving the electrical recordings, this minimized intracellular ion accumulation or depletion as well. Enlarged shank geometry allowed for fast intracellular perfusion as shown by fluorescence imaging, also via pulled quartz or plastic tubes, which could be inserted very close to the pipette tip.
Collapse
|
45
|
Imperfect space clamp permits electrotonic interactions between inhibitory and excitatory synaptic conductances, distorting voltage clamp recordings. PLoS One 2011; 6:e19463. [PMID: 21559357 PMCID: PMC3085473 DOI: 10.1371/journal.pone.0019463] [Citation(s) in RCA: 57] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2011] [Accepted: 03/30/2011] [Indexed: 11/18/2022] Open
Abstract
The voltage clamp technique is frequently used to examine the strength and composition of synaptic input to neurons. Even accounting for imperfect voltage control of the entire cell membrane ("space clamp"), it is often assumed that currents measured at the soma are a proportional indicator of the postsynaptic conductance. Here, using NEURON simulation software to model somatic recordings from morphologically realistic neurons, we show that excitatory conductances recorded in voltage clamp mode are distorted significantly by neighboring inhibitory conductances, even when the postsynaptic membrane potential starts at the reversal potential of the inhibitory conductance. Analogous effects are observed when inhibitory postsynaptic currents are recorded at the reversal potential of the excitatory conductance. Escape potentials in poorly clamped dendrites reduce the amplitude of excitatory or inhibitory postsynaptic currents recorded at the reversal potential of the other conductance. In addition, unclamped postsynaptic inhibitory conductances linearize the recorded current-voltage relationship of excitatory inputs comprising AMPAR and NMDAR-mediated components, leading to significant underestimation of the relative contribution by NMDARs, which are particularly sensitive to small perturbations in membrane potential. Voltage clamp accuracy varies substantially between neurons and dendritic arbors of different morphology; as expected, more reliable recordings are obtained from dendrites near the soma, but up to 80% of the synaptic signal on thin, distant dendrites may be lost when postsynaptic interactions are present. These limitations of the voltage clamp technique may explain how postsynaptic effects on synaptic transmission could, in some cases, be attributed incorrectly to presynaptic mechanisms.
Collapse
|
46
|
Abstract
With a conventional patch-clamp electrode, an Ag/AgCl wire sits stationary inside the pipette. To move from the gigaseal cell-attached configuration to whole-cell recording, suction is applied inside the pipette. We have designed and developed a novel Pushpen patch-clamp electrode, in which a W wire insulated and wound with Ag/AgCl wire can move linearly inside the pipette. The W wire has a conical tip, which can protrude from the pipette tip like a push pen, a procedure we call the Pushpen Operation. We use the Pushpen operation to impale the cell membrane in cell-attached configuration to go whole-cell without disruption of the gigaseal. We successfully recorded whole-cell currents from chinese hamster ovarian cells expressing influenza A virus protein A/M2, after obtaining whole-cell configuration with the Pushpen operation. This novel method of achieving whole-cell configuration may have a higher success rate than is the case with the conventional patch clamp technique.
Collapse
|
47
|
Oocyte triplet pairing for electrophysiological investigation of gap junctional coupling. J Neurosci Methods 2010; 188:280-6. [PMID: 20230857 PMCID: PMC2859429 DOI: 10.1016/j.jneumeth.2010.03.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2010] [Revised: 03/04/2010] [Accepted: 03/05/2010] [Indexed: 11/19/2022]
Abstract
Gap junctions formed by expressing connexin subunits in Xenopus oocytes provide a valuable tool for revealing the gating properties of intercellular gap junctions in electrically coupled cells. We describe a new method that consists of simultaneous triple recordings from 3 apposed oocytes expressing exogenous connexins. The advantages of this method are that in one single experiment, 1 oocyte serves as control while a pair of oocytes, which have been manipulated differently, may be tested for different gap junctional properties. Moreover, we can study simultaneously the gap junctional coupling of 3 different pairs of oocytes in the same preparation. If the experiment consists of testing the effect of a single drug, this approach will reduce the time required, as background coupling in control pairs of oocytes does not need to be measured separately as with the conventional 2 oocyte pairing. The triplet approach also increases confidence that any changes seen in junctional communication are due to the experimental treatment and not variation in the preparation of oocytes or execution of the experiment. In this study, we show the example of testing the gap junctional properties among 3 oocytes, 2 of which are expressing rat connexin36.
Collapse
|
48
|
Abstract
Lateral patch-clamping has emerged as a chip-based platform for automation of the conventional patch-clamp technique, the 'gold' standard for studying cellular ion channels. The conventional technique, as it relies on skilled-maneuver of glass micropipettes to patch cells, is extremely delicate, low in throughput, and thus cannot be used for primary screening of compounds against ion channels. Direct integration of glass capillaries on silicon provides lateral junctions for automated trapping and patching of cells. We demonstrate here a method of scaling up the lateral junctions to a standard 1536-well microtiter plate format. A single unit of 1536-well plate has been formed here on a 9 mm by 9 mm microstructured silicon with the inclusive of 16 wells molded in a capping layer made of polydimethylsiloxane (PDMS). The silicon substrate provides integrated glass capillaries (total 12) and their associated microfluidic network. Each glass capillary has an independent access through a dedicated well in PDMS and leads to a centralized channel in which cell suspension can be delivered through one of the remaining 4 wells. The unit has been tested on RBL-1 cells by recording whole-cell activity from inwardly rectifying endogenous potassium channels. A revised test protocol has been prescribed to avoid inaccurate readings due to altered ionic composition of the recording buffer when a typical suction is applied to capture cells.
Collapse
|
49
|
Automated sampling and data processing derived from biomimetic membranes. BIOINSPIRATION & BIOMIMETICS 2009; 4:044001. [PMID: 19901449 DOI: 10.1088/1748-3182/4/4/044001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Recent advances in biomimetic membrane systems have resulted in an increase in membrane lifetimes from hours to days and months. Long-lived membrane systems demand the development of both new automated monitoring equipment capable of measuring electrophysiological membrane characteristics and new data processing software to analyze and organize the large amounts of data generated. In this work, we developed an automated instrumental voltage clamp solution based on a custom-designed software controller application (the WaveManager), which enables automated on-line voltage clamp data acquisition applicable to long-time series experiments. We designed another software program for off-line data processing. The automation of the on-line voltage clamp data acquisition and off-line processing was furthermore integrated with a searchable database (DiscoverySheet) for efficient data management. The combined solution provides a cost efficient and fast way to acquire, process and administrate large amounts of voltage clamp data that may be too laborious and time consuming to handle manually.
Collapse
|
50
|
Patch clamping on plane glass-fabrication of hourglass aperture and high-yield ion channel recording. LAB ON A CHIP 2009; 9:2370-2380. [PMID: 19636469 DOI: 10.1039/b901025d] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Planar patch-clamp has revolutionized ion-channel measurement by eliminating laborious manipulation from the traditional micropipette approach and enabling high throughput. However, low yield in gigaseal formation and/or relatively high cost due to microfabricated processes are two main drawbacks. This paper presents patch clamping on glass substrate-an economical solution without sacrificing gigaseal yield rate. Two-stage CO(2) laser drilling methodology was used to generate an hourglass, funnel-like aperture of a specified diameter with smooth and debris-free surfaces on 150 microm borosilicate cover glass. For 1-3 microm apertures as patch-clamp chips, seal resistance was tested on human embryonic kidney, Chinese hamster ovary, and Jurkat T lymphoma cells with a gigaseal success rate of 62.5%, 43.6% and 66.7% respectively. Results also demonstrated both whole-cell and single channel recording on endogenously expressed ion channels to confirm the capability of different patch configurations.
Collapse
|