1
|
Zhou Z, He X, Xiao J, Pan J, Li M, Xu T, Zhang X. Machine learning-powered wearable interface for distinguishable and predictable sweat sensing. Biosens Bioelectron 2024; 265:116712. [PMID: 39208509 DOI: 10.1016/j.bios.2024.116712] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2024] [Revised: 05/29/2024] [Accepted: 08/26/2024] [Indexed: 09/04/2024]
Abstract
The constrained resources on wearable devices pose a challenge in meeting the demands for comprehensive sensing information, and current wearable non-enzymatic sensors face difficulties in achieving specific detection in biofluids. To address this issue, we have developed a highly selective non-enzymatic sweat sensor that seamlessly integrates with machine learning, ensuring reliable sensing and physiological monitoring of sweat biomarkers during exercise. The sensor consists of two electrodes supported by a microsystem that incorporates signal processing and wireless communication. The device generates four explainable features that can be used to accurately predict tyrosine and tryptophan concentrations, as well as sweat pH. The reliability of this device has been validated through rigorous statistical analysis, and its performance has been tested in subjects with and without supplemental amino acid intake during cycling trials. Notably, a robust linear relationship has been identified between tryptophan and tyrosine concentrations in the collected samples, irrespective of the pH dimension. This innovative sensing platform is highly portable and has significant potential to advance the biomedical applications of non-enzymatic sensors. It can markedly improve accuracy while decreasing costs.
Collapse
Affiliation(s)
- Zhongzeng Zhou
- College of Chemistry and Environmental Engineering, School of Biomedical Engineering of Health Science Center, The Institute for Advanced Study (IAS), Shenzhen University, Shenzhen, Guangdong, 518060, China
| | - Xuecheng He
- College of Chemistry and Environmental Engineering, School of Biomedical Engineering of Health Science Center, The Institute for Advanced Study (IAS), Shenzhen University, Shenzhen, Guangdong, 518060, China
| | - Jingyu Xiao
- College of Chemistry and Environmental Engineering, School of Biomedical Engineering of Health Science Center, The Institute for Advanced Study (IAS), Shenzhen University, Shenzhen, Guangdong, 518060, China
| | - Jiuxiang Pan
- College of Materials Science and Engineering, Shenzhen University, Shenzhen, Guangdong, 518060, China
| | - Mengmeng Li
- College of Chemistry and Environmental Engineering, School of Biomedical Engineering of Health Science Center, The Institute for Advanced Study (IAS), Shenzhen University, Shenzhen, Guangdong, 518060, China
| | - Tailin Xu
- College of Chemistry and Environmental Engineering, School of Biomedical Engineering of Health Science Center, The Institute for Advanced Study (IAS), Shenzhen University, Shenzhen, Guangdong, 518060, China.
| | - Xueji Zhang
- College of Chemistry and Environmental Engineering, School of Biomedical Engineering of Health Science Center, The Institute for Advanced Study (IAS), Shenzhen University, Shenzhen, Guangdong, 518060, China
| |
Collapse
|
2
|
Niu Z, Goto T. Effects of individual characteristics and local body functions on sweating response: A review. INTERNATIONAL JOURNAL OF BIOMETEOROLOGY 2024; 68:2185-2204. [PMID: 39141136 PMCID: PMC11519300 DOI: 10.1007/s00484-024-02758-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/02/2024] [Revised: 05/29/2024] [Accepted: 08/07/2024] [Indexed: 08/15/2024]
Abstract
In this study, we conducted a literature review to deepen our understanding of the sweating response of the thermoregulatory system, focusing on the influence of individual characteristics and local body functions. Among the factors related to individual characteristics, improvement in aerobic fitness had a positive effect on the sweating response, whereas aging exerted an inhibitory effect. Short-term artificial acclimation and seasonal heat acclimatization promoted sweating, whereas long-term geographical acclimatization suppressed sweating. Male exhibited higher sweat rates than female when the metabolic heat production was high. Individuals with smaller surface area-to-mass ratios tended to have higher sweat rates than those with larger ratios. Regarding local body functions, sweat distribution in the resting state showed high regional sweat rates in the lower limbs and torso, with higher values in the lower limbs when in the supine position and higher values in the torso when in the seated position. During exercise, the regional sweat rates was high in the torso, whereas the limbs exhibited relatively low sweat rates. These differences in sweat distribution stem from the thermoregulatory potential of each body region, which aims to efficiently regulate body temperature. Local effects have only been examined in the thigh and forearm, with temperature coefficient Q10 ranging from 2 to 5. Only the forehead showed significantly high thermosensitivity among all body regions.
Collapse
Affiliation(s)
- Zhuoxi Niu
- Department of Architecture and Building Science, Tohoku University, Sendai, Japan.
| | - Tomonobu Goto
- Department of Architecture and Building Science, Tohoku University, Sendai, Japan
| |
Collapse
|
3
|
Min S, Xu Z, Huang Y, Wu X, Zhan T, Yu X, Wang H, Xu B. 3D Wetting Gradient Janus Sports Bras for Efficient Sweat Removal: A Strategy to Improve Women's Sports Comfort and Health. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024; 20:e2404137. [PMID: 38990076 DOI: 10.1002/smll.202404137] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/22/2024] [Revised: 06/20/2024] [Indexed: 07/12/2024]
Abstract
Developing Janus fabrics with excellent one-way sweat transport capacity is an attractive way for providing comfort sensation and protecting the health during exercise. In this work, a 3D wetting gradient Janus fabric (3DWGJF) is first proposed to address the issue of excessive sweat accumulation in women's breasts, followed by integration with a sponge pad to form a 3D wetting gradient Janus sports bra (3DWGJSB). The 3D wetting gradient enables the prepared fabric to control the horizontal migration of sweat in one-way mode (x/y directions) and then unidirectionally penetrate downward (z direction), finally keeping the water content on the inner side of 3DWGJF (skin side) at ≈0%. In addition, the prepared 3DWGJF has good water vapor transmittance rate (WVTR: 0.0409 g cm-2 h-1) and an excellent water evaporation rate (0.4704 g h-1). Due to the high adhesion of transfer prints to the fabrics and their excellent mechanical properties, the 3DWGJF is remarkably durable and capable of withstanding over 500 laundering cycles and 400 abrasion cycles. This work may inspire the design and fabrication of next-generation moisture management fabrics with an effective sweat-removal function for women's health.
Collapse
Affiliation(s)
- Shuqiang Min
- School of Mechanical Engineering, Suzhou University of Science and Technology, Suzhou, 215009, China
| | - Zixuan Xu
- School of Mechanical Engineering, Suzhou University of Science and Technology, Suzhou, 215009, China
| | - Yange Huang
- School of Mechanical Engineering, Suzhou University of Science and Technology, Suzhou, 215009, China
| | - Xianchang Wu
- School of Mechanical Engineering, Suzhou University of Science and Technology, Suzhou, 215009, China
| | - Tonghuan Zhan
- School of Mechanical Engineering, Suzhou University of Science and Technology, Suzhou, 215009, China
| | - Xiaohua Yu
- School of Mechanical Engineering, Suzhou University of Science and Technology, Suzhou, 215009, China
| | - He Wang
- School of Mechanical Engineering, Suzhou University of Science and Technology, Suzhou, 215009, China
| | - Bing Xu
- School of Mechanical Engineering, Suzhou University of Science and Technology, Suzhou, 215009, China
| |
Collapse
|
4
|
Lin F, Vera Anaya D, Gong S, Yap LW, Lu Y, Yong Z, Cheng W. Gold Nanowire Sponge Electrochemistry for Permeable Wearable Sweat Analysis Comfortably and Wirelessly. ACS Sens 2024; 9:5414-5424. [PMID: 39298751 DOI: 10.1021/acssensors.4c01635] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/22/2024]
Abstract
Electrochemistry-based wearable and wireless sweat analysis is emerging as a promising noninvasive method for real-time health monitoring by tracking chemical and biological markers without the need for invasive blood sampling. It offers the potential to remotely monitor human sweat conditions in relation to metabolic health, stress, and electrolyte balance, which have implications for athletes, patients with chronic conditions, and individuals for the early detection and management of health issues. The state-of-the-art mainstream technology is dominated by the concept of a wearable microfluidic chip, typically based on elastomeric PDMS. While outstanding sensing performance can be realized, the design suffers from the poor permeability of PDMS, which could cause skin redness or irritation. Here, we introduce an omnidirectionally permeable, deformable, and wearable sweat analysis system based on gold nanowire sponges. We demonstrate the concept of all-in-one soft sponge electrochemistry, where the working, reference, and counter electrodes and electrolytes are all integrated within the sponge matrix. The intrinsic porosity of sponge in conjunction with vertically aligned gold nanowire electrodes gives rise to a high electrochemically active surface area of ∼67 cm2. Remarkably, this all-in-one sponge-based electrochemical system exhibited stable performance under a pressure of 10 kPa and 300% omnidirectional strain. The gold sponge biosensing electrodes could be sandwiched between two biocompatible sweat pads, which can serve as natural sweat collection and outflow layers. This naturally biocompatible and permeable platform can be integrated with wireless communication circuits, leading to a wireless sweat analysis system for the real-time monitoring of glucose, lactate, and pH during exercise.
Collapse
Affiliation(s)
- Fenge Lin
- Department of Chemical & Biological Engineering, Faculty of Engineering, Monash University, Clayton 3800, VIC, Australia
| | - David Vera Anaya
- Department of Chemical & Biological Engineering, Faculty of Engineering, Monash University, Clayton 3800, VIC, Australia
| | - Shu Gong
- Department of Chemical & Biological Engineering, Faculty of Engineering, Monash University, Clayton 3800, VIC, Australia
| | - Lim Wei Yap
- Department of Chemical & Biological Engineering, Faculty of Engineering, Monash University, Clayton 3800, VIC, Australia
| | - Yan Lu
- Department of Chemical & Biological Engineering, Faculty of Engineering, Monash University, Clayton 3800, VIC, Australia
| | - Zijun Yong
- Department of Chemical & Biological Engineering, Faculty of Engineering, Monash University, Clayton 3800, VIC, Australia
| | - Wenlong Cheng
- Department of Chemical & Biological Engineering, Faculty of Engineering, Monash University, Clayton 3800, VIC, Australia
- School of Biomedical Engineering, University of Sydney, Darlington 2008, NSW, Australia
| |
Collapse
|
5
|
Cinca-Morros S, Garcia-Rey S, Álvarez-Herms J, Basabe-Desmonts L, Benito-Lopez F. A physiological perspective of the relevance of sweat biomarkers and their detection by wearable microfluidic technology: A review. Anal Chim Acta 2024; 1327:342988. [PMID: 39266058 DOI: 10.1016/j.aca.2024.342988] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2024] [Revised: 07/15/2024] [Accepted: 07/17/2024] [Indexed: 09/14/2024]
Abstract
The great majority of published microfluidic wearable platforms for sweat sensing focus on the development of the technology to fabricate the device, the integration of sensing materials and actuators and the fluidics of sweat within the device. However, very few papers have discussed the physiological relevance of the metabolites measured using these novel approaches. In fact, some of the analytes present in sweat, which serve as biomarkers in blood, do not show a correlation with blood levels. This discrepancy can be attributed to factors such as contamination during measurements, the metabolism of sweat glands, or challenges in obtaining significant samples. The objective of this review is to present a critical and meaningful insight into the real applicability and potential use of wearable technology for improving health and sport performance. It also discusses the current limitations and future challenges of microfluidics, aiming to provide accurate information about the actual needs in this field. This work is expected to contribute to the future development of more suitable wearable microfluidic technology for health and sports science monitoring, using sweat as the biofluid for analysis.
Collapse
Affiliation(s)
- Sergi Cinca-Morros
- Microfluidics Cluster UPV/EHU, Analytical Microsystems & Materials for Lab-on-a-Chip (AMMa-LOAC) Group, Analytical Chemistry Department, University of the Basque Country UPV/EHU, Spain; Microfluidics Cluster UPV/EHU, BIOMICs Microfluidics Group, Lascaray Research Center, University of the Basque Country UPV/EHU, Vitoria-Gasteiz, Spain.
| | - Sandra Garcia-Rey
- Microfluidics Cluster UPV/EHU, Analytical Microsystems & Materials for Lab-on-a-Chip (AMMa-LOAC) Group, Analytical Chemistry Department, University of the Basque Country UPV/EHU, Spain; Microfluidics Cluster UPV/EHU, BIOMICs Microfluidics Group, Lascaray Research Center, University of the Basque Country UPV/EHU, Vitoria-Gasteiz, Spain
| | - Jesús Álvarez-Herms
- Research Group in Sports Genomics, Department of Genetics, Physical Anthropology and Animal Physiology, Faculty of Science and Technology, University of the Basque Country UPV/EHU, Leioa, Spain; PHYMOlab Research & Exercise Performance, Segovia, Spain
| | - Lourdes Basabe-Desmonts
- Microfluidics Cluster UPV/EHU, BIOMICs Microfluidics Group, Lascaray Research Center, University of the Basque Country UPV/EHU, Vitoria-Gasteiz, Spain; Basque Foundation of Science, IKERBASQUE, María Díaz Haroko Kalea, 3, 48013 Bilbao, Spain.
| | - Fernando Benito-Lopez
- Microfluidics Cluster UPV/EHU, Analytical Microsystems & Materials for Lab-on-a-Chip (AMMa-LOAC) Group, Analytical Chemistry Department, University of the Basque Country UPV/EHU, Spain.
| |
Collapse
|
6
|
Molly Subhash H, Ofoegbuna T, H Oliveira A, Pierce MC, Pillai S. Infrared thermal imaging for assessing human perspiration and evaluating antiperspirant product efficacy. Sci Rep 2024; 14:24994. [PMID: 39443511 PMCID: PMC11499672 DOI: 10.1038/s41598-024-73878-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2024] [Accepted: 09/23/2024] [Indexed: 10/25/2024] Open
Abstract
In humans, perspiration regulates core body temperature. Therefore, objectively evaluating it is essential for studying sweat gland function and mechanisms, particularly in antiperspirant efficacy studies. Various approaches have been developed for measuring human perspiration and evaluating antiperspirant efficacy, but are unsuitable for robust and routine clinical testing applications. This paper shows how infrared thermography, utilizing both high- and low-resolution modes, functions as a multiscale imaging modality. The high-resolution mode extracts physiological parameters (respiratory ~ 0.3 Hz and heart rate ~ 1.0 Hz) and visualizes the reduction of the sweat pore radii (from 359 ± 155 μm to 161 ± 47 μm) after antiperspirant application, consistent with known mechanisms of pore plugging and constriction induced by aluminum salts. The low-resolution mode quantitatively maps sweat retention in underarm clothing. All study participants in a clinical trial showed reduced sweat retention on their T-shirts due to antiperspirants, with reductions ranging from approximately 37-97% and an average reduction of 77.7 ± 22.1% using the developed methodology and tested antiperspirant. Overall, this non-invasive technique presents significant potential for clinical and personal care product evaluations, particularly in the early stages of product development.
Collapse
Affiliation(s)
| | | | - Abmael H Oliveira
- Colgate-Palmolive Company, Piscataway, NJ, 08854, USA
- Department of Biomedical Engineering, Rutgers, The State University of New Jersey, Piscataway, NJ, 08854, USA
| | - Mark C Pierce
- Department of Biomedical Engineering, Rutgers, The State University of New Jersey, Piscataway, NJ, 08854, USA
| | | |
Collapse
|
7
|
Nastase F, Busila C, Nicolescu AC, Marin CM, Tatu AL. Iontophoresis Improves the Impact on the Quality of Life of Children with Primary Hyperhidrosis-A Prospective Study and a Short Review. CHILDREN (BASEL, SWITZERLAND) 2024; 11:1253. [PMID: 39457218 PMCID: PMC11506013 DOI: 10.3390/children11101253] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2024] [Revised: 10/01/2024] [Accepted: 10/14/2024] [Indexed: 10/28/2024]
Abstract
BACKGROUND Primary hyperhidrosis (PH) is a somatic and idiopathic pediatric skin disease. The eccrine glands are tiny and very numerous, with approximately 3 million distributed throughout the skin. There is no commonly accepted amount of sweating to define hyperhidrosis, but people with this disease suffer real limitations integrating into society, which can be quantified through quality of life measurement scales. We want to draw attention to this disease and its impact on children's quality of life because it is significant and there are no studies conducted on groups consisting solely of children. METHODS There are various quality of life evaluation questionnaires for hyperhidrosis. We studied 103 children with hyperhidrosis by monitoring their sweat severity and its impact on quality of life, using the Hyperhidrosis Disease Severity Scale. We compared the scale results before and after 10 days of iontophoresis. This study includes only children under 18 years old, treated with iontophoresis. RESULTS The average age of the group is 11.84 ± 2.89 years. Treatment success is recorded in 68 (66.02%) children, but a change in the score is recorded in 74 (71.84%) children. The average HDSS score at T0 is 2.95 ± 0.70, compared to the HDSS score at T1 of 1.92 ± 0.86. CONCLUSIONS Hyperhidrosis has a negative impact on daily life, especially self-esteem, occupational productivity, emotional well-being, and interpersonal relationships. Iontophoresis is a safe and effective treatment method that reduces the severity of hyperhidrosis and increases the quality of life.
Collapse
Affiliation(s)
- Florentina Nastase
- Neuropsychomotor Rehabilitation Department, “Sf. Ioan” Emergency Clinical Hospital for Children, 800487 Galati, Romania;
| | - Camelia Busila
- Clinical Medical Department, Faculty of Medicine and Pharmacy, “Dunarea de Jos” University, 800008 Galati, Romania; (C.M.M.); (A.L.T.)
- Pediatrics Department, “Sf. Ioan” Emergency Clinical Hospital for Children, 800487 Galati, Romania
| | | | - Cristina Mihaela Marin
- Clinical Medical Department, Faculty of Medicine and Pharmacy, “Dunarea de Jos” University, 800008 Galati, Romania; (C.M.M.); (A.L.T.)
- Pediatrics Department, “Sf. Ioan” Emergency Clinical Hospital for Children, 800487 Galati, Romania
| | - Alin Laurentiu Tatu
- Clinical Medical Department, Faculty of Medicine and Pharmacy, “Dunarea de Jos” University, 800008 Galati, Romania; (C.M.M.); (A.L.T.)
- Multidisciplinary Integrated Center of Dermatological Interface Research MIC-DIR, “Dunărea de Jos” University, 800201 Galati, Romania
- Dermatology Department, “Sfanta Cuvioasa Parascheva” Hospital of Infectious Diseases, 800179 Galati, Romania
| |
Collapse
|
8
|
Cai J, Cao M, Bai J, Sun M, Ma C, Emran MY, Kotb A, Bo X, Zhou M. Flexible epidermal wearable sensor for Athlete's sweat biomarkers monitoring. Talanta 2024; 282:126986. [PMID: 39383716 DOI: 10.1016/j.talanta.2024.126986] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2024] [Revised: 09/26/2024] [Accepted: 10/03/2024] [Indexed: 10/11/2024]
Abstract
Wearable sweat sensors hold great promise for the monitoring of athletic sweat biomarkers that are reflective of physical status and the inimitable feature of wearable sensors to conduct dynamic sweat analysis in situ. However, the preparative methods of wearable patches for monitoring athlete's biomarkers are often complicated. Here, we demonstrate the first example of "sports lab-on-skin" as a fully integrated epidermal sweat sensor through simple laser engraving and laser cutting methods, which enables on-body and wirelessly measuring sweat Na+, sweat K+, sweat lactate, and initial sweat rate for physical status assessment. We test the performance of the "sports lab-on-skin" in both physically trained and un-trained groups under the same exercise intensity. We also validate the influence of different scenarios (water intake, breakfast, and exercise intensity) on dehydration time, sweat K+ level, sweat lactate level, and initial sweat rate.
Collapse
Affiliation(s)
- Jian Cai
- Key Laboratory of Polyoxometalate and Reticular Material Chemistry of Ministry of Education, Key Laboratory of Nanobiosensing and Nanobioanalysis at Universities of Jilin Province, Analysis and Testing Center, Department of Chemistry, Northeast Normal University, Changchun, Jilin Province, 130024, China
| | - Mengzhu Cao
- Key Laboratory of Polyoxometalate and Reticular Material Chemistry of Ministry of Education, Key Laboratory of Nanobiosensing and Nanobioanalysis at Universities of Jilin Province, Analysis and Testing Center, Department of Chemistry, Northeast Normal University, Changchun, Jilin Province, 130024, China
| | - Jing Bai
- Key Laboratory of Polyoxometalate and Reticular Material Chemistry of Ministry of Education, Key Laboratory of Nanobiosensing and Nanobioanalysis at Universities of Jilin Province, Analysis and Testing Center, Department of Chemistry, Northeast Normal University, Changchun, Jilin Province, 130024, China
| | - Mimi Sun
- Key Laboratory of Polyoxometalate and Reticular Material Chemistry of Ministry of Education, Key Laboratory of Nanobiosensing and Nanobioanalysis at Universities of Jilin Province, Analysis and Testing Center, Department of Chemistry, Northeast Normal University, Changchun, Jilin Province, 130024, China
| | - Chongbo Ma
- Key Laboratory of Polyoxometalate and Reticular Material Chemistry of Ministry of Education, Key Laboratory of Nanobiosensing and Nanobioanalysis at Universities of Jilin Province, Analysis and Testing Center, Department of Chemistry, Northeast Normal University, Changchun, Jilin Province, 130024, China
| | - Mohammed Y Emran
- Chemistry Department, Faculty of Science, Al-Azhar University, Assiut, 71524, Egypt
| | - Ahmed Kotb
- Chemistry Department, Faculty of Science, Al-Azhar University, Assiut, 71524, Egypt
| | - Xiangjie Bo
- Key Laboratory of Polyoxometalate and Reticular Material Chemistry of Ministry of Education, Key Laboratory of Nanobiosensing and Nanobioanalysis at Universities of Jilin Province, Analysis and Testing Center, Department of Chemistry, Northeast Normal University, Changchun, Jilin Province, 130024, China.
| | - Ming Zhou
- Key Laboratory of Polyoxometalate and Reticular Material Chemistry of Ministry of Education, Key Laboratory of Nanobiosensing and Nanobioanalysis at Universities of Jilin Province, Analysis and Testing Center, Department of Chemistry, Northeast Normal University, Changchun, Jilin Province, 130024, China.
| |
Collapse
|
9
|
Holland-Winkler AM, Hamil BK. Hydration Considerations to Improve the Physical Performance and Health of Firefighters. J Funct Morphol Kinesiol 2024; 9:182. [PMID: 39449476 PMCID: PMC11503342 DOI: 10.3390/jfmk9040182] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/15/2024] [Revised: 09/19/2024] [Accepted: 09/27/2024] [Indexed: 10/26/2024] Open
Abstract
Background/Objectives: Firefighters are exposed to a high level of stress as they often perform physically challenging work in hazardous environments while responsible for rescuing and keeping those around them safe. To add to this stress, they are also required to work in heavy, unbreathable personal protective equipment which promotes dehydration. These occupational demands paired with dehydration may lead to increased core temperatures, cardiac strain, and overall risk for sudden cardiac events. Thus, it is important to include hydration assessments and determine fluid needs when firefighters are on shift to ensure their personal safety as well as the safety of those around them by optimizing physical performance by maintaining adequate hydration. Therefore, the purpose of this review is to identify markers of hydration, classifications of hydration status, current hydration recommendations, and hydration interventions that may contribute to the overall clarity of hydration protocols that may optimize performance and health of firefighters. In addition, the impact of common medications, exercise training, and health conditions on hydration status related to firefighters will be discussed. Methods: A comprehensive literature search was conducted to discuss the purpose statements. Results: Hydration recommendations for firefighters include (1) assessing hydration status with multiple measurements including body mass, urine specific gravity and thirst sensation, and (2) following general hydration recommendations on rest days and exercise hydration protocols during firefighting activities which may be altered according to hydration status measurements. Conclusion: Randomized controlled trials in firefighters are needed to determine the impact of maintaining adequate hydration on health markers.
Collapse
Affiliation(s)
| | - Blake K. Hamil
- Department of Medicine, Augusta University, 1120 15th Street, Augusta, GA 30912, USA;
| |
Collapse
|
10
|
Ma R, Li D, Xu C, Yang J, Huang J, Guo Z. Fabricated advanced textile for personal thermal management, intelligent health monitoring and energy harvesting. Adv Colloid Interface Sci 2024; 332:103252. [PMID: 39053159 DOI: 10.1016/j.cis.2024.103252] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2024] [Revised: 05/15/2024] [Accepted: 07/16/2024] [Indexed: 07/27/2024]
Abstract
Fabrics are soft against the skin, flexible, easily accessible and able to wick away perspiration, to some extent for local private thermal management. In this review, we classify smart fabrics as passive thermal management fabrics and active thermal management fabrics based on the availability of outside energy consumption in the manipulation of heat generation and dissipation from the human body. The mechanism and research status of various thermal management fabrics are introduced in detail, and the article also analyses the advantages and disadvantages of various smart thermal management fabrics, achieving a better and more comprehensive comprehension of the current state of research on smart thermal management fabrics, which is quite an important reference guide for our future research. In addition, with the progress of science and technology, the social demand for fabrics has shifted from keeping warm to improving health and quality of life. E-textiles have potential value in areas such as remote health monitoring and life signal detection. New e-textiles are designed to mimic the skin, sense biological data and transmit information. At the same time, the ultra-moisturizing properties of the fabric's thermal management allow for applications beyond just the human body to energy. E-textiles hold great promise for energy harvesting and storage. The article also introduces the application of smart fabrics in life forms and energy harvesting. By combining electronic technology with textiles, e-textiles can be manufactured to promote human well-being and quality of life. Although smart textiles are equipped with more intelligent features, wearing comfort must be the first thing to be ensured in the multi-directional application of textiles. Eventually, we discuss the dares and prospects of smart thermal management fabric research.
Collapse
Affiliation(s)
- Rong Ma
- School of Materials Science and Engineering, Jiangsu University, Zhenjiang 212013, People's Republic of China
| | - Deke Li
- School of materials engineering, Lanzhou Institute of Technology, Lanzhou 730050, People's Republic of China; State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, People's Republic of China.
| | - Chenggong Xu
- State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, People's Republic of China; University of Chinese Academy of Sciences, Beijing 100049, People's Republic of China
| | - Juan Yang
- School of Materials Science and Engineering, Jiangsu University, Zhenjiang 212013, People's Republic of China.
| | - Jinxia Huang
- State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, People's Republic of China
| | - Zhiguang Guo
- Hubei Collaborative Innovation Centre for Advanced Organic Chemical Materials and Ministry of Education Key Laboratory for the Green Preparation and Application of Functional Materials, Hubei University, Wuhan 430062, People's Republic of China; State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, People's Republic of China
| |
Collapse
|
11
|
Loureiro MDP, Novais PM, Coelho RM, Paulin JAN. Sexual effects and long-term outcomes of endoscopic lumbar sympathectomy for plantar hyperhidrosis in men: a cross-sectional study. J Vasc Bras 2024; 23:e20240014. [PMID: 39421693 PMCID: PMC11486464 DOI: 10.1590/1677-5449.202400142] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2024] [Accepted: 05/13/2024] [Indexed: 10/19/2024] Open
Abstract
Background Plantar hyperhidrosis (PHH) is a disease with high psychosocial impact, and endoscopic lumbar sympathectomy (ELS) has been shown to be the best choice for treatment, but with some concerns such as compensatory sweating (CS) and sexual effects (SE), particularly in men. Objectives The aim of this study is to evaluate the long-term effectiveness of ELS for controlling PHH in men, its side effects, and perceived sexual modifications. Methods A cross-sectional study including only male patients operated for PHH with ELS between 2014-2022 at a private practice. During remote interviews, patients were asked about symptoms before and after ELS and about the postoperative effects on PHH. They were also objectively asked about any SE during the postoperative period. Validated quality of life for hyperhidrosis and erectile function questionnaires were also administered. Results 10 male patients averaging 4.26±2.86 years post-ELS were interviewed. Eight of them (80%) achieved complete response (≥80% of sweat reduction) in the first month after surgery and this response was maintained up to the interview date. Two patients had partial response. In six patients, CS occurred, with 5 reporting it as non-troublesome. Six patients reported some type of SE, but none reported erectile dysfunction. Regarding the functional results, all patients rated ELS from good (10%) to very good (30%) or excellent (60%). Conclusions Endoscopic lumbar sympathectomy was effective for treatment of plantar hyperhidrosis in these patients, improving their quality of life and providing lasting PHH control, with some transient sexual dysfunctions that did not impair their sexual life.
Collapse
|
12
|
Watanabe D, Muraki I, Yatsuya H, Tamakoshi A. Association between predicted level of water turnover deficit and all-cause and cause-specific mortalities among Japanese adults: The Japan Collaborative Cohort Study. Am J Clin Nutr 2024:S0002-9165(24)00753-6. [PMID: 39322034 DOI: 10.1016/j.ajcnut.2024.09.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2024] [Revised: 09/11/2024] [Accepted: 09/17/2024] [Indexed: 09/27/2024] Open
Abstract
BACKGROUND Although water is essential for maintaining health and life, the association between water turnover as an indicator of daily water requirement and water deficit and mortality is unclear. OBJECTIVES We aimed to investigate this association in Japanese adults. METHODS A total of 63,488 (36,739 females and 26,749 males) Japanese aged 40-79 y in the Japan Collaborative Cohort Study in 1988-1990 were followed up their mortality through 2009. Water turnover was calculated considering lifestyle and environmental factors using an equation previously developed by the International Doubly Labeled Water Database Group. Participants were classified into sex-specific quintiles based on their water turnover. Water deficit levels were calculated from water turnover and dietary water consumption, which were estimated using a validated questionnaire. RESULTS The mean daily water turnovers were 2950 and 3466 mL in females and males, respectively. During 19.4 years of median follow-up (1,039,914 person-years), 12,551 deaths were recorded. After adjusting for lifestyle and medical history, the bottom quintile was associated with higher hazard ratios (HRs) of mortality from all causes (females-HR: 1.26; 95% CI: 1.12, 1.41; males-HR: 1.18; 95% CI: 1.07, 1.29) and cardiovascular disease (CVD). In spline analyses, the water turnover range with the lowest HR for all-cause mortality was 3000-3300 mL/d in females and the water turnover at which the HR for all-cause mortality plateaued was ∼3500-3700 mL/d in males. Water deficiency levels were associated with all-cause and CVD-related mortality in both sexes. CONCLUSIONS The association between water turnover and deficit and all-cause and CVD-related mortalities (especially coronary artery disease and ischemic stroke) in adults is L-shaped. These findings may be useful for setting the target values of water requirement, and differences between dietary requirements and actual intake may bridge the knowledge gap in water-mortality associations.
Collapse
Affiliation(s)
- Daiki Watanabe
- Faculty of Sport Sciences, Waseda University, Tokorozawa-city, Saitama, Japan; National Institute of Health and Nutrition, National Institutes of Biomedical Innovation, Health and Nutrition, Settsu-city, Osaka, Japan
| | - Isao Muraki
- Division of Public Health, Department of Social and Environmental Medicine, Graduate School of Medicine, Osaka University, Suita-city, Osaka, Japan
| | - Hiroshi Yatsuya
- Department of Public Health and Health Systems, Nagoya University, Graduate School of Medicine, Showa-ku, Nagoya, Japan.
| | - Akiko Tamakoshi
- Department of Public Health, Graduate School of Medicine, Hokkaido University, Sapporo-city, Hokkaido, Japan
| |
Collapse
|
13
|
Howe CM, Coull BA, Papatheodorou S, Luttmann-Gibson H, Rifas-Shiman SL, Wilson A, Kloog I, Di Q, Zanobetti A, Koutrakis P, Schwartz JD, Oken E, Gold DR. Relative humidity, temperature, and hypertensive disorders of pregnancy: Findings from the Project Viva cohort. ENVIRONMENTAL RESEARCH 2024; 257:119211. [PMID: 38782342 PMCID: PMC11304542 DOI: 10.1016/j.envres.2024.119211] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/19/2024] [Revised: 04/24/2024] [Accepted: 05/20/2024] [Indexed: 05/25/2024]
Abstract
BACKGROUND Preeclampsia is a multi-system hypertensive disorder of pregnancy that is a leading cause of maternal and fetal morbidity and mortality. Prior studies disagree on the cause and even the presence of seasonal patterns in its incidence. Using unsuitable time windows for seasonal exposures can bias model results, potentially explaining these inconsistencies. OBJECTIVES We aimed to investigate humidity and temperature as possible causes for seasonal trends in preeclampsia in Project Viva, a prebirth cohort in Boston, Massachusetts, considering only exposure windows that precede disease onset. METHODS Using the Parameter-elevation Relationships on Independent Slopes Model (PRISM) Climate Dataset, we estimated daily residential temperature and relative humidity (RH) exposures during pregnancy. Our primary multinomial regression adjusted for person-level covariates and season. Secondary analyses included distributed lag models (DLMs) and adjusted for ambient air pollutants including fine particulates (PM2.5). We used Generalized Additive Mixed Models (GAMMs) for systolic blood pressure (SBP) trajectories across hypertensive disorder statuses to confirm exposure timing. RESULTS While preeclampsia is typically diagnosed late in pregnancy, GAMM-fitted SBP trajectories for preeclamptic and non-preeclamptic women began to diverge at around 20 weeks' gestation, confirming the need to only consider early exposures. In the primary analysis with 1776 women, RH in the early second trimester, weeks 14-20, was associated with significantly higher odds of preeclampsia (OR per IQR increase: 1.81, 95% CI: 1.10, 2.97). The DLM corroborated this window, finding a positive association from weeks 12-20. There were no other significant associations between RH or temperature and preeclampsia or gestational hypertension in any other time period. DISCUSSION The association between preeclampsia and RH in the early second trimester was robust to model choice, suggesting that RH may contribute to seasonal trends in preeclampsia incidence. Differences between these results and those of prior studies could be attributable to exposure timing differences.
Collapse
Affiliation(s)
- Christina M Howe
- Department of Biostatistics, Harvard TH Chan School of Public Health, Boston, MA, USA.
| | - Brent A Coull
- Department of Biostatistics, Harvard TH Chan School of Public Health, Boston, MA, USA; Department of Environmental Health, Harvard TH Chan School of Public Health, Boston, MA, USA
| | - Stefania Papatheodorou
- Department of Biostatistics and Epidemiology, Rutgers School of Public Health, Piscataway, NJ, USA; Department of Epidemiology, Harvard TH Chan School of Public Health, Boston, MA, USA
| | - Heike Luttmann-Gibson
- Department of Environmental Health, Harvard TH Chan School of Public Health, Boston, MA, USA
| | - Sheryl L Rifas-Shiman
- Division of Chronic Disease Research Across the Lifecourse, Department of Population Medicine, Harvard Medical School and Harvard Pilgrim Health Care Institute, Boston, MA, USA
| | - Ander Wilson
- Department of Statistics, Colorado State University, Fort Collins, CO, USA
| | - Itai Kloog
- Department of Environmental Medicine and Public Health at the Icahn School of Medicine at Mount Sinai, New York, NY, USA; Department of Geography at Ben Gurion University of the Negev, Beersheba, Israel
| | - Qian Di
- Vanke School of Public Health, Tsinghua University, Beijing, China
| | - Antonella Zanobetti
- Department of Environmental Health, Harvard TH Chan School of Public Health, Boston, MA, USA
| | - Petros Koutrakis
- Department of Environmental Health, Harvard TH Chan School of Public Health, Boston, MA, USA
| | - Joel D Schwartz
- Department of Environmental Health, Harvard TH Chan School of Public Health, Boston, MA, USA
| | - Emily Oken
- Division of Chronic Disease Research Across the Lifecourse, Department of Population Medicine, Harvard Medical School and Harvard Pilgrim Health Care Institute, Boston, MA, USA; Department of Nutrition, Harvard TH Chan School of Public Health, Boston, MA, USA
| | - Diane R Gold
- Department of Environmental Health, Harvard TH Chan School of Public Health, Boston, MA, USA; Channing Laboratory, Brigham and Women's Hospital, Boston, MA, USA
| |
Collapse
|
14
|
Saha T, Khan MI, Sandhu SS, Yin L, Earney S, Zhang C, Djassemi O, Wang Z, Han J, Abdal A, Srivatsa S, Ding S, Wang J. A Passive Perspiration Inspired Wearable Platform for Continuous Glucose Monitoring. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024:e2405518. [PMID: 39264314 DOI: 10.1002/advs.202405518] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/20/2024] [Revised: 08/30/2024] [Indexed: 09/13/2024]
Abstract
The demand for glucose monitoring devices has witnessed continuous growth from the rising diabetic population. The traditional approach of blood glucose (BG) sensor strip testing generates only intermittent glucose readings. Interstitial fluid-based devices measure glucose dynamically, but their sensing approaches remain either minimally invasive or prone to skin irritation. Here, a sweat glucose monitoring system is presented, which completely operates under rest with no sweat stimulation and can generate real-time BG dynamics. Osmotically driven hydrogels, capillary action with paper microfluidics, and self-powered enzymatic biochemical sensor are used for simultaneous sweat extraction, transport, and glucose monitoring, respectively. The osmotic forces facilitate greater flux inflow and minimize sweat rate fluctuations compared to natural perspiration-based sampling. The epidermal platform is tested on fingertip and forearm under varying physiological conditions. Personalized calibration models are developed and validated to obtain real-time BG information from sweat. The estimated BG concentration showed a good correlation with measured BG concentration, with all values lying in the A+B region of consensus error grid (MARD = 10.56% (fingertip) and 13.17% (forearm)). Overall, the successful execution of such osmotically driven continuous BG monitoring system from passive sweat can be a useful addition to the next-generation continuous sweat glucose monitors.
Collapse
Affiliation(s)
- Tamoghna Saha
- Aiiso Yufeng Li Family Department of Chemical and Nanoengineering, University of California San Diego, La Jolla, CA, 92093, USA
| | - Muhammad Inam Khan
- Aiiso Yufeng Li Family Department of Chemical and Nanoengineering, University of California San Diego, La Jolla, CA, 92093, USA
| | - Samar Singh Sandhu
- Aiiso Yufeng Li Family Department of Chemical and Nanoengineering, University of California San Diego, La Jolla, CA, 92093, USA
| | - Lu Yin
- Aiiso Yufeng Li Family Department of Chemical and Nanoengineering, University of California San Diego, La Jolla, CA, 92093, USA
| | - Sara Earney
- Aiiso Yufeng Li Family Department of Chemical and Nanoengineering, University of California San Diego, La Jolla, CA, 92093, USA
| | - Chenyang Zhang
- Aiiso Yufeng Li Family Department of Chemical and Nanoengineering, University of California San Diego, La Jolla, CA, 92093, USA
| | - Omeed Djassemi
- Aiiso Yufeng Li Family Department of Chemical and Nanoengineering, University of California San Diego, La Jolla, CA, 92093, USA
- Department of Bioengineering, University of California San Diego, La Jolla, CA, 92093, USA
| | - Zongnan Wang
- Department of Mechanical Engineering, University of California San Diego, La Jolla, CA, 92093, USA
| | - Jintong Han
- Department of Mechanical Engineering, University of California San Diego, La Jolla, CA, 92093, USA
| | - Abdulhameed Abdal
- Department of Mechanical Engineering, University of California San Diego, La Jolla, CA, 92093, USA
| | - Samarth Srivatsa
- Department of Bioengineering, University of California San Diego, La Jolla, CA, 92093, USA
| | - Shichao Ding
- Aiiso Yufeng Li Family Department of Chemical and Nanoengineering, University of California San Diego, La Jolla, CA, 92093, USA
| | - Joseph Wang
- Aiiso Yufeng Li Family Department of Chemical and Nanoengineering, University of California San Diego, La Jolla, CA, 92093, USA
| |
Collapse
|
15
|
Childs A, Mayol B, Lasalde-Ramírez JA, Song Y, Sempionatto JR, Gao W. Diving into Sweat: Advances, Challenges, and Future Directions in Wearable Sweat Sensing. ACS NANO 2024; 18:24605-24616. [PMID: 39185844 DOI: 10.1021/acsnano.4c10344] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/27/2024]
Abstract
Sweat analysis has advanced from diagnosing cystic fibrosis and testing for illicit drugs to noninvasive monitoring of health biomarkers. This article introduces the rapid development of wearable and flexible sweat sensors, highlighting key milestones and various sensing strategies for real-time monitoring of analytes. We discuss challenges such as developing high-performance nanomaterial-based biosensors, ensuring continuous sweat production and sampling, achieving high sweat/blood correlation, and biocompatibility. The potential of machine learning to enhance these sensors for personalized healthcare is presented, enabling real-time tracking and prediction of physiological changes and disease onset. Leveraging advancements in flexible electronics, nanomaterials, biosensing, and data analytics, wearable sweat biosensors promise to revolutionize disease management, prevention, and prediction, promoting healthier lifestyles and transforming medical practices globally.
Collapse
Affiliation(s)
- Andre Childs
- Department of Electrical and Computer Engineering, Rice University, Houston, Texas 77005, United States
| | - Beatriz Mayol
- Department of Electrical and Computer Engineering, Rice University, Houston, Texas 77005, United States
| | - José A Lasalde-Ramírez
- Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, Pasadena, California 91125, United States
| | - Yu Song
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, 999077, China
| | - Juliane R Sempionatto
- Department of Electrical and Computer Engineering, Rice University, Houston, Texas 77005, United States
| | - Wei Gao
- Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, Pasadena, California 91125, United States
| |
Collapse
|
16
|
Wu Y, Li X, Madsen KE, Zhang H, Cho S, Song R, Nuxoll RF, Xiong Y, Liu J, Feng J, Yang T, Zhang K, Aranyosi AJ, Wright DE, Ghaffari R, Huang Y, Nuzzo RG, Rogers JA. Skin-interfaced microfluidic biosensors for colorimetric measurements of the concentrations of ketones in sweat. LAB ON A CHIP 2024; 24:4288-4295. [PMID: 39193649 DOI: 10.1039/d4lc00588k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/29/2024]
Abstract
Ketones, such as beta-hydroxybutyrate (BHB), are important metabolites that can be used to monitor for conditions such as diabetic ketoacidosis (DKA) and ketosis. Compared to conventional approaches that rely on samples of urine or blood evaluated using laboratory techniques, processes for monitoring of ketones in sweat using on-body sensors offer significant advantages. Here, we report a class of soft, skin-interfaced microfluidic devices that can quantify the concentrations of BHB in sweat based on simple and low-cost colorimetric schemes. These devices combine microfluidic structures and enzymatic colorimetric BHB assays for selective and accurate analysis. Human trials demonstrate the broad applicability of this technology in practical scenarios, and they also establish quantitative correlations between the concentration of BHB in sweat and in blood. The results represent a convenient means for managing DKA and aspects of personal nutrition/wellness.
Collapse
Affiliation(s)
- Yunyun Wu
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA.
- Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL 60208, USA
| | - Xinming Li
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA.
- Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL 60208, USA
- Department of Biomedical Engineering, Northwestern University, Evanston, IL 60208, USA
| | - Kenneth E Madsen
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA.
- Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL 60208, USA
- Department of Chemistry, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA.
| | - Haohui Zhang
- Department of Civil and Environmental Engineering, Northwestern University, Evanston, IL 60208, USA
| | - Soongwon Cho
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA.
- Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL 60208, USA
| | - Ruihao Song
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA.
- Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL 60208, USA
| | - Ravi F Nuxoll
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA.
- Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL 60208, USA
- Department of Materials Science and Engineering, Northwestern University, Evanston, IL 60208, USA
- Department of Physics and Astronomy, Northwestern University, Evanston, IL 60208, USA
| | - Yirui Xiong
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA.
- Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL 60208, USA
| | - Jiaqi Liu
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA.
- Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL 60208, USA
| | - Jingyuan Feng
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA.
- Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL 60208, USA
- Department of Materials Science and Engineering, Northwestern University, Evanston, IL 60208, USA
| | - Tianyu Yang
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA.
- Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL 60208, USA
| | - Kaiqing Zhang
- Department of Civil and Environmental Engineering, Northwestern University, Evanston, IL 60208, USA
- State Key Laboratory of Structural Analysis, Optimization and CAE Software for Industrial Equipment, Department of Engineering Mechanics, Dalian University of Technology, Dalian, 116024, Liaoning, China
| | - Alexander J Aranyosi
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA.
- Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL 60208, USA
- Epicore Biosystems, Inc., Cambridge, MA 02139, USA
| | | | - Roozbeh Ghaffari
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA.
- Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL 60208, USA
- Department of Biomedical Engineering, Northwestern University, Evanston, IL 60208, USA
- Epicore Biosystems, Inc., Cambridge, MA 02139, USA
| | - Yonggang Huang
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA.
- Department of Civil and Environmental Engineering, Northwestern University, Evanston, IL 60208, USA
- Department of Materials Science and Engineering, Northwestern University, Evanston, IL 60208, USA
- Department of Mechanical Engineering, Northwestern University, Evanston, IL 60208, USA
| | - Ralph G Nuzzo
- Department of Chemistry, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA.
| | - John A Rogers
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA.
- Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL 60208, USA
- Department of Biomedical Engineering, Northwestern University, Evanston, IL 60208, USA
- Department of Materials Science and Engineering, Northwestern University, Evanston, IL 60208, USA
- Department of Neurological Surgery, Northwestern University, Evanston, IL 60208, USA
| |
Collapse
|
17
|
Tungkijanansin N, Sirinara P, Tunvirachaisakul C, Srikam S, Kittiban K, Thongthip S, Kerdcharoen T, Maes M, Kulsing C. Sweat-based stress screening with gas chromatography-ion mobility spectrometry and electronic nose. Anal Chim Acta 2024; 1320:343029. [PMID: 39142792 DOI: 10.1016/j.aca.2024.343029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2024] [Revised: 07/22/2024] [Accepted: 07/24/2024] [Indexed: 08/16/2024]
Abstract
BACKGROUND Diagnosis of stress generally involves uses of questionnaires which can provide biased results. The more reliable approach relies on observation of individual symptoms by psychiatrists which is time consuming and could not be applicable for massive scale screening tests. This research established alternative approaches with gas chromatography-ion mobility spectrometry (GC-IMS) and electronic nose (e-nose) to perform fast stress screening based on fingerprinting of highly volatile compounds in headspaces of sweat. The investigated samples were obtained from 154 female nurse volunteers who also provided the data of questionnaire-based mental health scores with the high stress cases confirmed by psychiatrists. RESULTS The interviews by psychiatrists revealed 14 volunteers with high stress. Their axillary sweat samples and that from 32 nurses with low/moderate stress (controls) were collected onto cotton rods and analysed with GC-IMS. The possible marker peaks were selected based on the accuracy data. They were tentatively identified as ammonia, diethyl ether, methanol, octane, pentane, acetone and dimethylamine which could involve different endogenous mechanisms or the relationships with the local microbiomes. The data were further analysed using partial least squares discriminant analysis with the receiver operating characteristic curves showing the optimum accuracy, sensitivity and selectivity of 87%, 86% and 88%, respectively. Providing that the samples were obtained from the nurses without deodorant uses, the high stress cases could be screened using e-nose sensors with the accuracy of 89%. The sensor responses could be correlated with the marker peak area data in GC-IMS with the coefficients ranging from -0.70 to 0.80. SIGNIFICANCE This represents the first investigation of highly volatile compound markers in sweat for high stress screening. The established methods were simple, reliable, rapid and non-invasive, which could be further adapted into the portable platform of e-nose sensors with the practical application to perform the screening tests for nurses in Phra Nakorn Si Ayutthaya hospital, Thailand.
Collapse
Affiliation(s)
- Nuttanee Tungkijanansin
- Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand
| | - Patthrarawalai Sirinara
- Department of Preventive and Social Medicine, Faculty of Medicine, Chulalongkorn University, Bangkok, 10330, Thailand
| | - Chavit Tunvirachaisakul
- Department of Psychiatry, Faculty of Medicine, Chulalongkorn University, Bangkok, 10330, Thailand; Center of Excellence in Cognitive Impairment and Dementia, Faculty of Medicine, Chulalongkorn University, Bangkok, 10330, Thailand
| | - Saran Srikam
- Department of Occupational Medicine, Phra Nakhon Si Ayutthaya Hospital, Phra Nakhon Si Ayutthaya, 13000, Thailand
| | - Kasinee Kittiban
- Department of Occupational Medicine, Phra Nakhon Si Ayutthaya Hospital, Phra Nakhon Si Ayutthaya, 13000, Thailand
| | - Siriwan Thongthip
- Maha Chakri Sirindhorn Clinical Research Center Under the Royal Patronage, Research Affairs, Faculty of Medicine, Chulalongkorn University, Bangkok, 10330, Thailand
| | - Teerakiat Kerdcharoen
- Department of Physics, Faculty of Science, and Research Network of NANOTEC at Mahidol University National Nanotechnology Center, Bangkok, 10400, Thailand
| | - Michael Maes
- Department of Psychiatry, Faculty of Medicine, Chulalongkorn University, Bangkok, 10330, Thailand; Center of Excellence in Cognitive Impairment and Dementia, Faculty of Medicine, Chulalongkorn University, Bangkok, 10330, Thailand
| | - Chadin Kulsing
- Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand; Electrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand.
| |
Collapse
|
18
|
Peel JS, McNarry MA, Heffernan SM, Nevola VR, Kilduff LP, Coates K, Dudley E, Waldron M. The effect of 8-day oral taurine supplementation on thermoregulation during low-intensity exercise at fixed heat production in hot conditions of incremental humidity. Eur J Appl Physiol 2024; 124:2561-2576. [PMID: 38582816 PMCID: PMC11365861 DOI: 10.1007/s00421-024-05478-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2023] [Accepted: 03/22/2024] [Indexed: 04/08/2024]
Abstract
PURPOSE To determine the effect of taurine supplementation on sweating and core temperature responses, including the transition from compensable to uncompensable heat stress, during prolonged low-intensity exercise of a fixed-heat production (~ 200W/m2) in hot conditions (37.5 °C), at both fixed and incremental vapour-pressure. METHODS Fifteen females (n = 3) and males (n = 12; 27 ± 5 years, 78 ± 9 kg, V ˙ O2max 50.3 ± 7.8 mL/kg/min), completed a treadmill walking protocol (~ 200W/m2 heat production [Ḣprod]) in the heat (37.5 ± 0.1 °C) at fixed-(16-mmHg) and ramped-humidity (∆1.5-mmHg/5-min) following 1 week of oral taurine supplementation (50 mg/kg/bm) or placebo, in a double-blind, randomised, cross-over design. Participants were assessed for whole-body sweat loss (WBSL), local sweat rate (LSR), sweat gland activation (SGA), core temperature (Tcore), breakpoint of compensability (Pcrit) and calorimetric heat transfer components. Plasma volume and plasma taurine concentrations were established through pre- and post-trial blood samples. RESULTS Taurine supplementation increased WBSL by 26.6% and 5.1% (p = 0.035), LSR by 15.5% and 7.8% (p = 0.013), SGA (1 × 1 cm) by 32.2% and 29.9% (p < 0.001) and SGA (3 × 3 cm) by 22.1% and 17.1% (p = 0.015) during the fixed- and ramped-humidity exercise periods, respectively. Evaporative heat loss was enhanced by 27% (p = 0.010), heat-storage reduced by 72% (p = 0.024) and Pcrit was greater in taurine vs placebo (25.0-mmHg vs 21.7-mmHg; p = 0.002). CONCLUSION Taurine supplementation increased sweating responses during fixed Ḣprod in hot conditions, prior to substantial heat strain and before the breakpoint of compensability, demonstrating improved thermoregulatory capacity. The enhanced evaporative cooling and reduced heat-storage delayed the subsequent upward inflection in Tcore-represented by a greater Pcrit-and offers a potential dietary supplementation strategy to support thermoregulation.
Collapse
Affiliation(s)
- Jennifer S Peel
- A-STEM Centre, Faculty of Science and Engineering, Swansea University, Swansea, UK.
| | - Melitta A McNarry
- A-STEM Centre, Faculty of Science and Engineering, Swansea University, Swansea, UK
| | - Shane M Heffernan
- A-STEM Centre, Faculty of Science and Engineering, Swansea University, Swansea, UK
| | - Venturino R Nevola
- A-STEM Centre, Faculty of Science and Engineering, Swansea University, Swansea, UK
- Defence Science and Technology Laboratory (Dstl), Fareham, Hampshire, UK
| | - Liam P Kilduff
- A-STEM Centre, Faculty of Science and Engineering, Swansea University, Swansea, UK
- Welsh Institute of Performance Science, Swansea University, Swansea, UK
| | - Kathryn Coates
- Swansea University Medical School, Faculty of Medicine, Health and Life Science, Swansea University, Swansea, UK
| | - Ed Dudley
- Swansea University Medical School, Faculty of Medicine, Health and Life Science, Swansea University, Swansea, UK
| | - Mark Waldron
- A-STEM Centre, Faculty of Science and Engineering, Swansea University, Swansea, UK
- Welsh Institute of Performance Science, Swansea University, Swansea, UK
- School of Health and Behavioural Sciences, University of the Sunshine Coast, Sippy Downs, QLD, Australia
| |
Collapse
|
19
|
Okawara H, Sawada T, Nakashima D, Fujitsuka H, Muramoto Y, Hinokuma D, Oshikiri Y, Ishizaki K, Miki J, Hara R, Sano M, Sato K, Nakamura M, Nagura T, Katsumata Y. Lactate threshold evaluation in swimming using a sweat lactate sensor: A prospective study. Eur J Sport Sci 2024; 24:1302-1312. [PMID: 39126367 PMCID: PMC11369350 DOI: 10.1002/ejsc.12179] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2024] [Revised: 07/04/2024] [Accepted: 07/25/2024] [Indexed: 08/12/2024]
Abstract
Since assessing aerobic capacity is key to enhancing swimming performance, a simple and widely applicable technology should be developed. Therefore, we aimed to noninvasively visualize real-time changes in sweat lactate (sLA) levels during swimming and investigate the relationship between lactate thresholds in sweat (sLT) and blood (bLT). This prospective study included 24 university swimmers (age: 20.7 s ± 1.8 years, 58% male) who underwent exercise tests at incremental speeds with or without breaks in a swimming flume to measure heart rate (HR), bLT, and sLT based on sLA levels using a waterproof wearable lactate sensor attached to the dorsal upper arm on two different days. The correlation coefficient and Bland-Altman methods were used to verify the similarities of the sLT with bLT and personal performance. In all tests, dynamic changes in sLA levels were continuously measured and projected onto the wearable device without delay, artifacts, or contamination. Following an initial minimal current response, with increasing speed the sLA levels increased substantially, coinciding with a continuous rise in HR. The speed at sLT strongly correlated with that at bLT (p < 0.01 and r = 0.824). The Bland-Altman plot showed a strong agreement (mean difference: 0.08 ± 0.1 m/s). This prospective study achieved real-time sLA monitoring during swimming, even with vigorous movement. The sLT closely approximated bLT; both were subsequently validated for their relevance to performance.
Collapse
Affiliation(s)
- Hiroki Okawara
- Department of Orthopaedic SurgeryKeio University School of MedicineTokyoJapan
| | - Tomonori Sawada
- Department of Orthopaedic SurgeryKeio University School of MedicineTokyoJapan
| | - Daisuke Nakashima
- Department of Orthopaedic SurgeryKeio University School of MedicineTokyoJapan
| | - Haruki Fujitsuka
- Department of Orthopaedic SurgeryKeio University School of MedicineTokyoJapan
| | - Yuki Muramoto
- Institute for Integrated Sports MedicineKeio University School of MedicineTokyoJapan
| | - Daigo Hinokuma
- Department of Orthopaedic SurgeryKeio University School of MedicineTokyoJapan
| | - Yuta Oshikiri
- School of Sport Sciences Waseda UniversityTokyoJapan
| | | | - Jiro Miki
- College of Science and Technology Department of Liberal Arts and ScienceNihon UniversityTokyoJapan
| | - Reira Hara
- College of Sports Sciences Department of Competitive SportsNihon UniversityTokyoJapan
| | - Motoaki Sano
- Department of CardiologyKeio University School of MedicineTokyoJapan
| | - Kazuki Sato
- Institute for Integrated Sports MedicineKeio University School of MedicineTokyoJapan
| | - Masaya Nakamura
- Department of Orthopaedic SurgeryKeio University School of MedicineTokyoJapan
| | - Takeo Nagura
- Department of Orthopaedic SurgeryKeio University School of MedicineTokyoJapan
- Department of Clinical BiomechanicsKeio University School of MedicineTokyoJapan
| | - Yoshinori Katsumata
- Institute for Integrated Sports MedicineKeio University School of MedicineTokyoJapan
- Department of CardiologyKeio University School of MedicineTokyoJapan
| |
Collapse
|
20
|
Huang Y, Zhong H, Yang R, Pan Y, Lin J, Lee CKW, Chen S, Tan M, Lu X, Poon WY, Yuan Q, Li MG. Multifunctional laser-induced graphene circuits and laser-printed nanomaterials toward non-invasive human kidney function monitoring. Biosens Bioelectron 2024; 259:116386. [PMID: 38749285 DOI: 10.1016/j.bios.2024.116386] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2024] [Revised: 04/29/2024] [Accepted: 05/12/2024] [Indexed: 06/03/2024]
Abstract
Faced with the increasing prevalence of chronic kidney disease (CKD), portable monitoring of CKD-related biomarkers such as potassium ion (K+), creatinine (Cre), and lactic acid (Lac) levels in sweat has shown tremendous potential for early diagnosis. However, a rapidly manufacturable portable device integrating multiple CKD-related biomarker sensors for ease of sweat testing use has yet to be reported. Here, a portable electrochemical sensor integrated with multifunctional laser-induced graphene (LIG) circuits and laser-printed nanomaterials based working electrodes fabricated by fully automatic laser manufacturing is proposed for non-invasive human kidney function monitoring. The sensor comprises a two-electrode LIG circuit for K+ sensing, a three-electrode LIG circuit with a Kelvin compensating connection for Cre and Lac sensing, and a printed circuit board based portable electrochemical workstation. The working electrodes containing Cu and Cu2O nanoparticles fabricated by two-step laser printing show good sensitivity and selectivity toward Cre and Lac sensing. The sensor circuits are fabricated by generating a hydrophilic-hydrophobic interface on a patterned LIG through laser. This sensor recruited rapid laser manufacturing and integrated with multifunctional LIG circuits and laser-printed nanomaterials based working electrodes, which is a potential kidney function monitoring solution for healthy people and kidney disease patients.
Collapse
Affiliation(s)
- Yangyi Huang
- Center for Smart Manufacturing, Division of Integrative Systems and Design, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, 999077, China
| | - Haosong Zhong
- Center for Smart Manufacturing, Division of Integrative Systems and Design, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, 999077, China
| | - Rongliang Yang
- Center for Smart Manufacturing, Division of Integrative Systems and Design, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, 999077, China
| | - Yexin Pan
- Center for Smart Manufacturing, Division of Integrative Systems and Design, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, 999077, China; Hong Kong Branch of Chinese National Engineering Research Center for Tissue Restoration and Reconstruction, Clear Water Bay, Kowloon, Hong Kong SAR, 999077, China
| | - Jing Lin
- Center for Smart Manufacturing, Division of Integrative Systems and Design, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, 999077, China
| | - Connie Kong Wai Lee
- Center for Smart Manufacturing, Division of Integrative Systems and Design, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, 999077, China
| | - Siyu Chen
- Center for Smart Manufacturing, Division of Integrative Systems and Design, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, 999077, China
| | - Min Tan
- Center for Smart Manufacturing, Division of Integrative Systems and Design, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, 999077, China
| | - Xupeng Lu
- Center for Smart Manufacturing, Division of Integrative Systems and Design, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, 999077, China
| | - Wing Yan Poon
- Center for Smart Manufacturing, Division of Integrative Systems and Design, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, 999077, China
| | - Qiaoyaxiao Yuan
- Center for Smart Manufacturing, Division of Integrative Systems and Design, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, 999077, China
| | - Mitch Guijun Li
- Center for Smart Manufacturing, Division of Integrative Systems and Design, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, 999077, China; Hong Kong Branch of Chinese National Engineering Research Center for Tissue Restoration and Reconstruction, Clear Water Bay, Kowloon, Hong Kong SAR, 999077, China.
| |
Collapse
|
21
|
Aleksandrova M, Mateev V, Iliev I. Behavior of Polymer Electrode PEDOT:PSS/Graphene on Flexible Substrate for Wearable Biosensor at Different Loading Modes. NANOMATERIALS (BASEL, SWITZERLAND) 2024; 14:1357. [PMID: 39195395 DOI: 10.3390/nano14161357] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/22/2024] [Revised: 08/14/2024] [Accepted: 08/16/2024] [Indexed: 08/29/2024]
Abstract
In recent years, flexible and wearable biosensor technologies have gained significant attention due to their potential to revolutionize healthcare monitoring. Among the various components involved in these biosensors, the electrode material plays a crucial role in ensuring accurate and reliable detection. In this regard, polymer electrodes, such as Poly(3,4 ethylenedioxythiophene): poly(styrenesulfonate), combined with graphene (PEDOT:PSS/graphene), have emerged as promising candidates due to their unique mechanical properties and excellent electrical conductivity. Understanding the mechanical behavior of these polymer electrodes on flexible substrates is essential to ensure the stability and durability of wearable biosensors. In this paper, PEDOT:PSS/graphene composite was spray-coated on flexible substrates at different growth conditions to explore the effect of the deposition parameters and mode of mechanical loading (longitudinal or transversal) on the electrical and mechanical behavior of the fabricated samples. It was found that the coating grown at lower temperatures and higher spraying pressure exhibited stable behavior no matter the applied stress type.
Collapse
Affiliation(s)
- Mariya Aleksandrova
- Department of Microelectronics, Technical University of Sofia, 1000 Sofia, Bulgaria
| | - Valentin Mateev
- Department of Electrical Apparatus, Technical University of Sofia, 1000 Sofia, Bulgaria
| | - Ivo Iliev
- Department of Electronics, Technical University of Sofia, 1000 Sofia, Bulgaria
| |
Collapse
|
22
|
Rajendran K, Krishnan UM. Biomarkers in Alzheimer's disease. Clin Chim Acta 2024; 562:119857. [PMID: 38986861 DOI: 10.1016/j.cca.2024.119857] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2024] [Revised: 07/05/2024] [Accepted: 07/06/2024] [Indexed: 07/12/2024]
Abstract
Alzheimer's disease (AD) is among the most common neurodegenerative disorders. AD is characterized by deposition of neurofibrillary tangles and amyloid plaques, leading to associated secondary pathologies, progressive neurodegeneration, and eventually death. Currently used diagnostics are largely image-based, lack accuracy and do not detect early disease, ie, prior to onset of symptoms, thus limiting treatment options and outcomes. Although biomarkers such as amyloid-β and tau protein in cerebrospinal fluid have gained much attention, these are generally limited to disease progression. Unfortunately, identification of biomarkers for early and accurate diagnosis remains a challenge. As such, body fluids such as sweat, serum, saliva, mucosa, tears, and urine are under investigation as alternative sources for biomarkers that can aid in early disease detection. This review focuses on biomarkers identified through proteomics in various biofluids and their potential for early and accurate diagnosis of AD.
Collapse
Affiliation(s)
- Kayalvizhi Rajendran
- Centre for Nanotechnology & Advanced Biomaterials, SASTRA Deemed University, Thanjavur, India; School of Chemical & Biotechnology, SASTRA Deemed University, Thanjavur, India
| | - Uma Maheswari Krishnan
- Centre for Nanotechnology & Advanced Biomaterials, SASTRA Deemed University, Thanjavur, India; School of Arts, Sciences, Humanities, & Education, SASTRA Deemed University, Thanjavur, India.
| |
Collapse
|
23
|
Fan B, Wu Y, Guo H, Yu F, Liu LE, Yu S, Wang J, Wang Y. Self-assembly of cascade nanoenzyme glucose oxidase encapsulated in copper benzenedicarboxylate for wearable sweat-glucose colorimetric sensors with smartphone readout. Anal Chim Acta 2024; 1316:342852. [PMID: 38969409 DOI: 10.1016/j.aca.2024.342852] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2023] [Revised: 06/06/2024] [Accepted: 06/07/2024] [Indexed: 07/07/2024]
Abstract
BACKGROUND With the advent of personalized medical approaches, precise and tailored treatments are expected to become widely accepted for the prevention and treatment of diabetes. Paper-based colorimetric sensors that function in combination with smartphones have been rapidly developed in recent years because it does not require additional equipment and is inexpensive and easy to perform. In this study, we developed a portable, low-cost, and wearable sweat-glucose detection device for in situ detection. RESULTS The sensor adopted an integrated biomimetic nanoenzyme of glucose oxidase (GOx) encapsulated in copper 1, 4-benzenedicarboxylate (CuBDC) (GOx@CuBDC) through a biomimetic mineralization process. CuBDC exhibited a peroxide-like effect, cascade catalytic effect with the encapsulated GOx, and increased the enzyme stability. GOx@CuBDC and 3,3,5,5-tetramethylbenzidine were combined to form a hybrid membrane that achieved single-step paper-based glucose detection. SIGNIFICANCE AND NOVELTY This GOx@CuBDC-based colorimetric glucose sensor was used to quantitatively analyze the sweat-glucose concentration with smartphone readings. The sensor exhibited a good linear relationship over the concentration range of 40-900 μM and a limit of detection of 20.7 μM (S/N = 3). Moreover, the sensor performed well in situ monitoring and in evaluating variations based on the consumption of foods with different glycemic indices. Therefore, the fabricated wearable sweat-glucose sensors exhibited optimal practical application performance.
Collapse
Affiliation(s)
- Binghua Fan
- College of Public Health, Zhengzhou University, Zhengzhou, Henan, 450001, China
| | - Yongjun Wu
- College of Public Health, Zhengzhou University, Zhengzhou, Henan, 450001, China; The Key Laboratory of Nanomedicine and Health Inspection of Zhengzhou, Zhengzhou, Henan, 450001, China
| | - Hongchao Guo
- College of Public Health, Zhengzhou University, Zhengzhou, Henan, 450001, China
| | - Fei Yu
- College of Public Health, Zhengzhou University, Zhengzhou, Henan, 450001, China
| | - Li-E Liu
- College of Public Health, Zhengzhou University, Zhengzhou, Henan, 450001, China
| | - Songcheng Yu
- College of Public Health, Zhengzhou University, Zhengzhou, Henan, 450001, China
| | - Jia Wang
- College of Public Health, Zhengzhou University, Zhengzhou, Henan, 450001, China
| | - Yilin Wang
- College of Public Health, Zhengzhou University, Zhengzhou, Henan, 450001, China.
| |
Collapse
|
24
|
Weller RB. Sunlight: Time for a Rethink? J Invest Dermatol 2024; 144:1724-1732. [PMID: 38661623 DOI: 10.1016/j.jid.2023.12.027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2023] [Revised: 12/20/2023] [Accepted: 12/22/2023] [Indexed: 04/26/2024]
Abstract
UVR is a skin carcinogen, yet no studies link sun exposure to increased all-cause mortality. Epidemiological studies from the United Kingdom and Sweden link sun exposure with reduced all-cause, cardiovascular, and cancer mortality. Vitamin D synthesis is dependent on UVB exposure. Individuals with higher serum levels of vitamin D are healthier in many ways, yet multiple trials of oral vitamin D supplementation show little benefit. Growing evidence shows that sunlight has health benefits through vitamin D-independent pathways, such as photomobilization of nitric oxide from cutaneous stores with reduction in cardiovascular morbidity. Sunlight has important systemic health benefit as well as risks.
Collapse
Affiliation(s)
- Richard B Weller
- Centre for Inflammation Research, Institute for Regeneration and Repair, The University of Edinburgh, Edinburgh, United Kingdom; Department of Dermatology, The University of Edinburgh, Edinburgh, United Kingdom.
| |
Collapse
|
25
|
Singaram S, Ramakrishnan K, Selvam J, Senthil M, Narayanamurthy V. Sweat gland morphology and physiology in diabetes, neuropathy, and nephropathy: a review. Arch Physiol Biochem 2024; 130:437-451. [PMID: 36063413 DOI: 10.1080/13813455.2022.2114499] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/16/2022] [Accepted: 08/02/2022] [Indexed: 11/02/2022]
Abstract
Context: Sweat glands (SGs) play a vital role in thermal regulation. The function and structure are altered during the different pathological conditions.Objective: These alterations are studied through three techniques: biopsy, sweat analytes and electrical activity of SG.Methods: The morphological study of SG through biopsy and various techniques involved in quantifying sweat analytes is focussed on here. Electrical activities of SG in diabetes, neuropathy and nephropathy cases are also discussed, highlighting their limitations and future scope.Results and Conclusion: The result of this review identified three areas of the knowledge gap. The first is wearable sensors to correlate pathological conditions. Secondly, there is no device to look for its structure and quantify its associated function. Finally, therapeutic applications of SG are explored, especially for renal failure. With these aspects, this paper provides information collection and correlates SG with pathologies related to diabetes. Hence this could help researchers develop suitable technologies for the gaps identified.
Collapse
Affiliation(s)
- Sudha Singaram
- Department of Biomedical Engineering, Rajalakshmi Engineering College, Chennai, Tamil Nadu, India
| | - Kalpana Ramakrishnan
- Department of Biomedical Engineering, Rajalakshmi Engineering College, Chennai, Tamil Nadu, India
| | - Jayashree Selvam
- Department of Biomedical Engineering, Rajalakshmi Engineering College, Chennai, Tamil Nadu, India
| | - Mallika Senthil
- Department of Biomedical Engineering, Rajalakshmi Engineering College, Chennai, Tamil Nadu, India
| | - Vigneswaran Narayanamurthy
- Faculty of Electrical and Electronic Engineering Technology, Universiti Teknikal Malaysia Melaka, Melaka, Malaysia
| |
Collapse
|
26
|
John K, Kathuria S, Peel J, Page J, Aitkenhead R, Felstead A, Heffernan SM, Jeffries O, Tallent J, Waldron M. Caffeine ingestion compromises thermoregulation and does not improve cycling time to exhaustion in the heat amongst males. Eur J Appl Physiol 2024; 124:2489-2502. [PMID: 38568259 PMCID: PMC11322244 DOI: 10.1007/s00421-024-05460-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Accepted: 03/04/2024] [Indexed: 08/16/2024]
Abstract
PURPOSE Caffeine is a commonly used ergogenic aid for endurance events; however, its efficacy and safety have been questioned in hot environmental conditions. The aim of this study was to investigate the effects of acute caffeine supplementation on cycling time to exhaustion and thermoregulation in the heat. METHODS In a double-blind, randomised, cross-over trial, 12 healthy caffeine-habituated and unacclimatised males cycled to exhaustion in the heat (35 °C, 40% RH) at an intensity associated with the thermoneutral gas exchange threshold, on two separate occasions, 60 min after ingesting caffeine (5 mg/kg) or placebo (5 mg/kg). RESULTS There was no effect of caffeine supplementation on cycling time to exhaustion (TTE) (caffeine; 28.5 ± 8.3 min vs. placebo; 29.9 ± 8.8 min, P = 0.251). Caffeine increased pulmonary oxygen uptake by 7.4% (P = 0.003), heat production by 7.9% (P = 0.004), whole-body sweat rate (WBSR) by 21% (P = 0.008), evaporative heat transfer by 16.5% (P = 0.006) and decreased estimated skin blood flow by 14.1% (P < 0.001) compared to placebo. Core temperature was higher by 0.6% (P = 0.013) but thermal comfort decreased by - 18.3% (P = 0.040), in the caffeine condition, with no changes in rate of perceived exertion (P > 0.05). CONCLUSION The greater heat production and storage, as indicated by a sustained increase in core temperature, corroborate previous research showing a thermogenic effect of caffeine ingestion. When exercising at the pre-determined gas exchange threshold in the heat, 5 mg/kg of caffeine did not provide a performance benefit and increased the thermal strain of participants.
Collapse
Affiliation(s)
- Kevin John
- Research Institute for Sport and Exercise, University of Canberra, Canberra, Australia
- Applied Sports Science Technology and Medicine Research Centre (A-STEM), Faculty of Science and Engineering, Bay Campus, Swansea University, Swansea, Wales, SA1 8EN, UK
| | - Sayyam Kathuria
- Applied Sports Science Technology and Medicine Research Centre (A-STEM), Faculty of Science and Engineering, Bay Campus, Swansea University, Swansea, Wales, SA1 8EN, UK
| | - Jenny Peel
- Applied Sports Science Technology and Medicine Research Centre (A-STEM), Faculty of Science and Engineering, Bay Campus, Swansea University, Swansea, Wales, SA1 8EN, UK
| | - Joe Page
- Applied Sports Science Technology and Medicine Research Centre (A-STEM), Faculty of Science and Engineering, Bay Campus, Swansea University, Swansea, Wales, SA1 8EN, UK
| | - Robyn Aitkenhead
- Applied Sports Science Technology and Medicine Research Centre (A-STEM), Faculty of Science and Engineering, Bay Campus, Swansea University, Swansea, Wales, SA1 8EN, UK
| | - Aimee Felstead
- Applied Sports Science Technology and Medicine Research Centre (A-STEM), Faculty of Science and Engineering, Bay Campus, Swansea University, Swansea, Wales, SA1 8EN, UK
| | - Shane M Heffernan
- Applied Sports Science Technology and Medicine Research Centre (A-STEM), Faculty of Science and Engineering, Bay Campus, Swansea University, Swansea, Wales, SA1 8EN, UK
| | - Owen Jeffries
- School of Biomedical, Nutritional and Sport Sciences, Newcastle University, Newcastle Upon Tyne, UK
| | - Jamie Tallent
- School of Sport, Rehabilitation, and Exercise Sciences, University of Essex, Colchester, UK
- Department of Physiotherapy, Faculty of Medicine, Nursing and Health Sciences, School of Primary and Allied Health Care, Monash University, Clayton, Australia
| | - Mark Waldron
- Applied Sports Science Technology and Medicine Research Centre (A-STEM), Faculty of Science and Engineering, Bay Campus, Swansea University, Swansea, Wales, SA1 8EN, UK.
- Welsh Institute of Performance Science, Swansea University, Swansea, UK.
- School of Health and Behavioural Sciences, University of the Sunshine Coast, Sippy Down, QLD, Australia.
| |
Collapse
|
27
|
Takei N, Inaba T, Morita Y, Kakinoki K, Hatta H, Kitaoka Y. Differential patterns of sweat and blood lactate concentration response during incremental exercise in varied ambient temperatures: A pilot study. Temperature (Austin) 2024; 11:247-253. [PMID: 39193045 PMCID: PMC11346536 DOI: 10.1080/23328940.2024.2375693] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2024] [Revised: 06/26/2024] [Accepted: 06/28/2024] [Indexed: 08/29/2024] Open
Abstract
Blood lactate concentration during exercise is a reliable indicator of energy metabolism and endurance performance. Lactate is also present in sweat, and sweating plays an important role in thermoregulation, especially in hot conditions. Recently, wearable sensors have enabled the real-time and noninvasive measurement of sweat lactate concentration, potentially serving as an alternative indicator of blood lactate response. However, the evidence regarding the relationship between sweat and blood lactate responses during incremental exercise in hot conditions is lacking. In a randomized cross-over design, six highly trained male runners completed two incremental treadmill tests under normal (20°C/50%RH) or hot (30°C/50%RH) conditions. The tests include 3-min running stages and 1-min recovery, starting at 12 km/h and increasing by 1 km/h at each stage. Blood and sweat lactate concentrations were measured at each stage to determine blood and sweat lactate thresholds (LT). Blood lactate concentrations were higher under hot conditions (p < 0.01), but there was no difference in the response pattern or velocity at blood LT between conditions. Significant early increase (p < 0.01) in sweat lactate and low velocity at sweat LT (p < 0.05) were observed under hot conditions. A significant correlation between blood and sweat lactate concentrations was found under normal conditions (p < 0.001) but not under hot conditions, and no significant correlations were observed between the velocity at blood and sweat LT. In conclusion, sweat lactate concentration does not consistently reflect blood lactate concentration during incremental exercise.
Collapse
Affiliation(s)
- Naoya Takei
- Research Institute of Physical Fitness, Japan Women's College of Physical Education, Tokyo, Japan
- Department of Sports Sciences, The University of Tokyo, Tokyo, Japan
| | - Takeru Inaba
- Department of Sports Sciences, The University of Tokyo, Tokyo, Japan
| | - Yuki Morita
- Department of Sports Sciences, The University of Tokyo, Tokyo, Japan
| | | | - Hideo Hatta
- Department of Sports Sciences, The University of Tokyo, Tokyo, Japan
| | - Yu Kitaoka
- Department of Human Sciences, Kanagawa University, Yokohama, Kanagawa, Japan
| |
Collapse
|
28
|
Jaiswal AK, Jose CT, Ramesh R, Nanani VK, Sadeghi K, Joshi A, Kompally K, Pathikonda G, Emady HN, Bheda B, Kavouras SA, Rykaczewski K. Simultaneous imaging of multi-pore sweat dynamics and evaporation rate measurement using wind tunnel ventilated capsule with infrared window. iScience 2024; 27:110304. [PMID: 39040057 PMCID: PMC11261446 DOI: 10.1016/j.isci.2024.110304] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2024] [Revised: 05/20/2024] [Accepted: 06/16/2024] [Indexed: 07/24/2024] Open
Abstract
Sweat evaporation is critical to human thermoregulation, but current understanding of the process on 20 μm to 2 cm scale is limited. To this end, we introduce a wind-tunnel-shaped ventilated capsule with an infrared window for simultaneous infrared sweat imaging and evaporation rate measurement. Implementing the capsule in pilot human subject tests suggests that the common assumption of sweat being an isothermal film is only valid when the evaporation rate is low and sweat forms puddles on the skin. Before transitioning to this filmwise mode, sweating occurs in cyclic dropwise mode, displaying a 3x higher mass transfer coefficient in the same conditions. Imaging highlighted distinct phenomena occurring during and between these modes including out-of-duct evaporation, pulsating droplets, temporary and eventually lasting crevice filling, and individual drop-to-film spreading. In all, sweat evaporation is an impactful area that our results show is ripe for exploration, which can be achieved quantitatively using the introduced platform.
Collapse
Affiliation(s)
- Ankush K. Jaiswal
- School for Engineering of Matter, Transport and Energy, Arizona State University, Tempe, AZ, USA
- Julie Ann Wrigley Global Futures Laboratory, Arizona State University, Tempe, AZ 85287, USA
| | - Cibin T. Jose
- School for Engineering of Matter, Transport and Energy, Arizona State University, Tempe, AZ, USA
| | - Rajesh Ramesh
- School for Engineering of Matter, Transport and Energy, Arizona State University, Tempe, AZ, USA
| | - Vinay K. Nanani
- School for Engineering of Matter, Transport and Energy, Arizona State University, Tempe, AZ, USA
| | - Kambiz Sadeghi
- School for Engineering of Matter, Transport and Energy, Arizona State University, Tempe, AZ, USA
- Julie Ann Wrigley Global Futures Laboratory, Arizona State University, Tempe, AZ 85287, USA
| | - Ankit Joshi
- School for Engineering of Matter, Transport and Energy, Arizona State University, Tempe, AZ, USA
- Julie Ann Wrigley Global Futures Laboratory, Arizona State University, Tempe, AZ 85287, USA
| | - Krishna Kompally
- School for Engineering of Matter, Transport and Energy, Arizona State University, Tempe, AZ, USA
| | - Gokul Pathikonda
- School for Engineering of Matter, Transport and Energy, Arizona State University, Tempe, AZ, USA
| | - Heather N. Emady
- School for Engineering of Matter, Transport and Energy, Arizona State University, Tempe, AZ, USA
| | - Bhaumik Bheda
- School for Engineering of Matter, Transport and Energy, Arizona State University, Tempe, AZ, USA
| | - Stavros A. Kavouras
- College of Health Solutions, Arizona State University, Phoenix, AZ 85004, USA
| | - Konrad Rykaczewski
- School for Engineering of Matter, Transport and Energy, Arizona State University, Tempe, AZ, USA
- Julie Ann Wrigley Global Futures Laboratory, Arizona State University, Tempe, AZ 85287, USA
| |
Collapse
|
29
|
Jeong JH, Park C. Comparative Study of 1444 nm Laser Monotherapy versus Integrated Liposuction in the Treatment of Axillary Osmidrosis. MEDICINA (KAUNAS, LITHUANIA) 2024; 60:1151. [PMID: 39064579 PMCID: PMC11278600 DOI: 10.3390/medicina60071151] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/21/2024] [Revised: 07/05/2024] [Accepted: 07/16/2024] [Indexed: 07/28/2024]
Abstract
Background and Objectives: The 1444 nm wavelength Neodymium:Yttrium-Aluminum-Garnet (Nd:YAG) laser treatment is an efficient method for treating axillary osmidrosis (AO); however, it has a relatively low treatment persistence. To address this issue, we performed integrated liposuction surgery with a laser to treat AO and compared the results with those of a group treated only with a laser. Materials and Methods: This study compared the outcomes of AO treatment between the two groups up to six months postoperatively. The first group of 18 patients underwent laser treatment alone, and the second group of 12 patients underwent integrated liposuction surgery in addition to laser treatment. Outcomes were assessed using the following variables: degree of malodor (DOM), sweating area, patient satisfaction, pain levels, and complications, such as burns, swelling, and contractures. Results: Compared to the laser-only group, the integrated liposuction group demonstrated significantly superior outcomes in terms of DOM (p = 0.002) and patient satisfaction (p = 0.006), as well as a reduction in the sweating area (p = 0.012). The pain rating was higher in the liposuction group, but the difference was not statistically significant (p = 0.054). Compared with the patients in the integrated liposuction treatment group, those in the laser treatment group exhibited a significantly higher number of burns under the axillae (p = 0.025). However, no significant differences were observed in the swelling or contracture between the groups. Conclusions: Integrated liposuction with laser therapy significantly improved treatment outcomes, including malodor, patient satisfaction, sweat test results, and decreased complication rates.
Collapse
Affiliation(s)
- Jae Hoon Jeong
- Department of Plastic and Reconstructive Surgery, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam-si 13620, Republic of Korea;
| | - Chongsoo Park
- Department of Plastic and Reconstructive Surgery, Inje University College of Medicine, Inje University Busan Paik Hospital, Busan 47392, Republic of Korea
| |
Collapse
|
30
|
Retzinger AC, Retzinger GS. The Acari Hypothesis, IV: revisiting the role of hygiene in allergy. FRONTIERS IN ALLERGY 2024; 5:1415124. [PMID: 39055609 PMCID: PMC11270752 DOI: 10.3389/falgy.2024.1415124] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2024] [Accepted: 06/21/2024] [Indexed: 07/27/2024] Open
Abstract
Allergy and its manifestations were first appreciated in the 1870 s. Today, the mechanism by which specific substances elicit allergic reactions remains poorly understood. This is problematic from a healthcare perspective because the prevalence of allergic disease and its societal costs are substantial. Regarding mechanistic understanding of allergy, a new proposal, The Acari Hypothesis, has been forwarded. The Hypothesis, borne from consideration of alpha-gal syndrome, postulates that acarians, i.e., mites and ticks, are operative agents of allergy. By way of their pathogenic payloads and salivary pattern recognition receptor(s), acarians potentiate in human hosts the generation of IgE against acarian dietary elements. Those elements account for most, if not all, known human allergens. Inasmuch as acarian-human interactions occur on human epithelial surfaces, it is to be expected factors that influence the presence and/or operation of acarians on those surfaces influence the expression of allergic diseases. In this report, it is proposed that two adaptations of catarrhine primates, i.e., Old World monkeys, apes and humans, evolved to deter acarian species: firstly, the expansion of eccrine glands across the entirety of body surface area, and, secondly, the secretion of sweat by those glands. Contemporary hygienic practices that reduce and/or disrupt the operation of eccrine glands are likely responsible for the increase in allergic disease seen today.
Collapse
Affiliation(s)
- Andrew C. Retzinger
- Department of Emergency Medicine, Camden Clark Medical Center, West Virginia University, Parkersburg, WV, United States
| | - Gregory S. Retzinger
- Department of Pathology, Feinberg School of Medicine, Northwestern University, Chicago, IL, United States
| |
Collapse
|
31
|
Fiska V, Papanikolaou E, Patila M, Prodromidis MI, Trachioti MG, Tzianni EI, Spyrou K, Angelidis P, Tsipouras MG. DEMIGOD: A Low-Cost Microcontroller-Based Closed-Loop System Integrating Nanoengineered Sweat-Based Glucose Monitoring and Controlled Transdermal Nanoemulsion Release of Hypoglycemic Treatment with a Software Application for Noninvasive Personalized Diabetes Care. MICROMACHINES 2024; 15:887. [PMID: 39064398 PMCID: PMC11278575 DOI: 10.3390/mi15070887] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/13/2024] [Revised: 06/12/2024] [Accepted: 06/22/2024] [Indexed: 07/28/2024]
Abstract
This study endeavored to design and develop an innovative closed-loop diagnostic and therapeutic system with the following objectives: (a) the noninvasive detection of glucose concentration in sweat utilizing nanonengineered screen-printed biosensors; (b) the management of measured data through a specialized computer system comprising both hardware and software components, thereby enabling the precise control of therapeutic responses via a patch-based nanomedicine delivery system. This initiative addresses the significant challenges inherent in the management of diabetes mellitus, including the imperative need for glucose-level monitoring to optimize glycemic control. Leveraging chronoamperometric results as a foundational dataset and the in vivo hypoglycemic activity of nanoemulsion formulations, this research underscores the efficacy and accuracy of glucose concentration estimation, decision-making mechanism responses, and transdermal hypoglycemic treatment effects, within the proposed system.
Collapse
Affiliation(s)
- Vasiliki Fiska
- Department of Electrical and Computer Engineering, University of Western Macedonia, 50100 Kozani, Greece; (V.F.); (P.A.)
| | - Eirini Papanikolaou
- Laboratory of Physiology, Faculty of Medicine, University of Ioannina, 45110 Ioannina, Greece;
| | - Michaela Patila
- Biotechnology Laboratory, Department of Biological Applications and Technologies, University of Ioannina, 45110 Ioannina, Greece;
| | - Mamas I. Prodromidis
- Laboratory of Analytical Chemistry, University of Ioannina, 45110 Ioannina, Greece; (M.I.P.); (M.G.T.); (E.I.T.)
| | - Maria G. Trachioti
- Laboratory of Analytical Chemistry, University of Ioannina, 45110 Ioannina, Greece; (M.I.P.); (M.G.T.); (E.I.T.)
| | - Eleni I. Tzianni
- Laboratory of Analytical Chemistry, University of Ioannina, 45110 Ioannina, Greece; (M.I.P.); (M.G.T.); (E.I.T.)
| | - Konstantinos Spyrou
- Department of Materials Science and Engineering, University of Ioannina, 45110 Ioannina, Greece;
| | - Pantelis Angelidis
- Department of Electrical and Computer Engineering, University of Western Macedonia, 50100 Kozani, Greece; (V.F.); (P.A.)
| | - Markos G. Tsipouras
- Department of Electrical and Computer Engineering, University of Western Macedonia, 50100 Kozani, Greece; (V.F.); (P.A.)
| |
Collapse
|
32
|
Isom M, Desaire H. Skin Surface Sebum Analysis by ESI-MS. Biomolecules 2024; 14:790. [PMID: 39062504 PMCID: PMC11274890 DOI: 10.3390/biom14070790] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2024] [Revised: 06/26/2024] [Accepted: 06/28/2024] [Indexed: 07/28/2024] Open
Abstract
The skin surface is an important sample source that the metabolomics community has only just begun to explore. Alterations in sebum, the lipid-rich mixture coating the skin surface, correlate with age, sex, ethnicity, diet, exercise, and disease state, making the skin surface an ideal sample source for future noninvasive biomarker exploration, disease diagnosis, and forensic investigation. The potential of sebum sampling has been realized primarily via electrospray ionization mass spectrometry (ESI-MS), an ideal approach to assess the skin surface lipidome. However, a better understanding of sebum collection and subsequent ESI-MS analysis is required before skin surface sampling can be implemented in routine analyses. Challenges include ambiguity in definitive lipid identification, inherent biological variability in sebum production, and methodological, technical variability in analyses. To overcome these obstacles, avoid common pitfalls, and achieve reproducible, robust outcomes, every portion of the workflow-from sample collection to data analysis-should be carefully considered with the specific application in mind. This review details current practices in sebum sampling, sample preparation, ESI-MS data acquisition, and data analysis, and it provides important considerations in acquiring meaningful lipidomic datasets from the skin surface. Forensic researchers investigating sebum as a means for suspect elimination in lieu of adequate fingerprint ridge detail or database matches, as well as clinical researchers interested in noninvasive biomarker exploration, disease diagnosis, and treatment monitoring, can use this review as a guide for developing methods of best-practice.
Collapse
Affiliation(s)
| | - Heather Desaire
- Department of Chemistry, University of Kansas, Lawrence, KS 66045, USA;
| |
Collapse
|
33
|
Shaban M, Amer FGM, Shaban MM. The impact of nursing sustainable prevention program on heat strain among agricultural elderly workers in the context of climate change. Geriatr Nurs 2024; 58:215-224. [PMID: 38838403 DOI: 10.1016/j.gerinurse.2024.05.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2024] [Revised: 05/13/2024] [Accepted: 05/22/2024] [Indexed: 06/07/2024]
Abstract
BACKGROUND This study assesses a geriatric nursing-led sustainable heat prevention program for elderly agricultural workers. It targets those aged 60 and above, addressing the heightened risk of heat strain in the era of climate change. METHODS A community-based quasi-experimental design involved 120 elderly agricultural workers, divided into intervention and control groups. The program, spanning three months, included education on hydration, rest, protective clothing, and recognition of heat-related illnesses. RESULTS The intervention led by geriatric nursing professionals showed significant improvements in heat strain metrics. The Heat Strain Score Index (HSSI) and the Observational-Perceptual Heat Strain Risk Assessment (OPHSRA) Index indicated increased safety levels and reduced risk categories among participants. CONCLUSIONS The study demonstrates the effectiveness of a geriatric nursing-led, tailored prevention program in reducing heat strain among elderly agricultural workers. It highlights the crucial role of nursing in adapting healthcare practices to the challenges posed by climate change. TRIAL REGISTRATION ClinicalTrials.gov, ID NCT06192069 retrospectively registered.
Collapse
|
34
|
Borsky KL, Rodrigues JN, Rodrigues R. The Effect of Climate on the Dose Requirements of Botulinum Toxin A in Cosmetic Interventions. Plast Reconstr Surg 2024; 154:57e-62e. [PMID: 37410613 DOI: 10.1097/prs.0000000000010913] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/08/2023]
Abstract
BACKGROUND Botulinum toxin A to the glabella is a popular cosmetic intervention. Functional musculature differences may arise from chronic behavioral adjustment to high sun exposure levels, requiring greater doses. This could affect clinical practice globally. This study investigated the effect of climate on real-world doses. METHODS The authors conducted a comparative cohort study using data from a registry from a single provider practicing across two centers: the United Kingdom and Malta. They classified one center as low sun exposure (United Kingdom winter month treatment) and the other as high sun exposure (Malta summer months). Patients were followed up once every 3 weeks and received top-up doses until full clinical paralysis was achieved. To standardize the comparison, the study included only women aged 35 to 60 years undergoing glabellar botulinum toxin treatment by experienced clinicians following standard procedures from 2012 to 2019. Smokers, those not seeking maximal paralysis, those documented as not compliant with posttreatment advice, those with colds or fevers, and those with broken cold supply chains were excluded. Univariable and multivariable analyses were undertaken. RESULTS A total of 523 patients were included: 292 "high-sun" patients and 231 "low-sun" patients. Mean total doses were significantly higher in the high-sun group (29.2 units versus 27.3 units; P = 0.0031). When correcting for age in multivariable analysis, the low-sun group still had lower total dose requirements ( P = 0.00574). CONCLUSION Patients injected with glabellar botulinum toxin in high-sun climates may have significantly increased dose requirements to achieve maximal paralysis. CLINICAL QUESTION/LEVEL OF EVIDENCE Therapeutic, III.
Collapse
Affiliation(s)
- Kim L Borsky
- From the Department of Plastic and Reconstructive Surgery, Stoke Mandeville Hospital
| | - Jeremy N Rodrigues
- From the Department of Plastic and Reconstructive Surgery, Stoke Mandeville Hospital
- Warwick Clinical Trials Unit, University of Warwick
| | - Raina Rodrigues
- Department of Plastic Surgery, Lister Hospital
- Aesthetic Virtue Limited (Malta); and Academy of Aesthetic Excellence
| |
Collapse
|
35
|
d'Astous ÉV, Dauphin-Ducharme P. Whole blood multiplex measurements using electrochemical aptamer-based biosensors. Chem Commun (Camb) 2024; 60:6419-6422. [PMID: 38828657 DOI: 10.1039/d4cc01452a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/05/2024]
Abstract
Simultaneous measurements of various molecules ("multiplex") using electrochemical biosensors typically require multiple electrode implementations, which for neonates, hemophiliacs, etc. is problematic. Here, we introduce the oxazine ATTO 700 into electrochemical aptamer-based biosensors to achieve "true" multiplex, continuous and real-time measurements of two different molecules in undiluted whole blood using a single electrode.
Collapse
Affiliation(s)
- Élodie V d'Astous
- Université de Sherbrooke, Département de Chimie, 2500 boul. de l'Université, Sherbrooke, J1K 2R1, Canada.
| | - Philippe Dauphin-Ducharme
- Université de Sherbrooke, Département de Chimie, 2500 boul. de l'Université, Sherbrooke, J1K 2R1, Canada.
| |
Collapse
|
36
|
Wei L, Zhou J, Li Z, Zhu H, Wu H, Zhu Y, Liu A. Quantitative analysis of sweat evaporation loss in epidermal microfluidic patches. RSC Adv 2024; 14:18406-18416. [PMID: 38860253 PMCID: PMC11163416 DOI: 10.1039/d4ra03483j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2024] [Accepted: 06/03/2024] [Indexed: 06/12/2024] Open
Abstract
Sweat analysis is identified as a promising biochemical technique for the non-invasive assessment of human health status. Epidermal microfluidic patches are the predominant sweat sampling and sensing devices. However, the sweat stored inside the patches may suffer from evaporation loss of moisture, which can increase the concentration of biomarkers and cause the biochemical analysis results of sweat to deviate from the actual results. This study focuses on quantitatively analysing the sweat evaporation loss within epidermal microfluidic patches. Analytical models based on the dissolution diffusion mechanism and corresponding partial differential equations for the diffusion process were initially developed. The analytical solution of the equation was derived using the method of separation of variables, and the steady-state concentration distribution of water in the materials of microfluidic patches was calculated when considering the application of epidermal microfluidics. Evaporation losses of sweat through different paths were quantitatively calculated and analysed, including permeation through covers, diffusion along microchannels, and absorption by sidewalls. Then, experiments on the evaporation loss of sweat within microfluidic patches were conducted to validate the theoretical calculations and analytical results. At last, the design of the anti-evaporation structure for microfluidic patches was discussed. This study can provide theoretical and experimental references for the design of water-retention structures in epidermal microfluidic patches, which significantly enhances the overall reliability of sweat biochemical analysis results.
Collapse
Affiliation(s)
- Lei Wei
- Key Laboratory of Functional Materials and Devices for Informatics of Anhui Higher Education Institute, Fuyang Normal University Fuyang 236037 P.R. China
- Key Laboratory of Optical Field Manipulation of Zhejiang Province, College of Science, Zhejiang Sci-Tech University Hangzhou 310018 P.R. China
| | - Jingjing Zhou
- Key Laboratory of Functional Materials and Devices for Informatics of Anhui Higher Education Institute, Fuyang Normal University Fuyang 236037 P.R. China
| | - Zhen Li
- Key Laboratory of Functional Materials and Devices for Informatics of Anhui Higher Education Institute, Fuyang Normal University Fuyang 236037 P.R. China
| | - Hui Zhu
- Key Laboratory of Functional Materials and Devices for Informatics of Anhui Higher Education Institute, Fuyang Normal University Fuyang 236037 P.R. China
| | - Huaping Wu
- Key Laboratory of Special Purpose Equipment and Advanced Processing Technology, Ministry of Education and Zhejiang Province, College of Mechanical Engineering, Zhejiang University of Technology Hangzhou 310023 P.R. China
| | - Yong Zhu
- Key Laboratory of Functional Materials and Devices for Informatics of Anhui Higher Education Institute, Fuyang Normal University Fuyang 236037 P.R. China
| | - Aiping Liu
- Key Laboratory of Optical Field Manipulation of Zhejiang Province, College of Science, Zhejiang Sci-Tech University Hangzhou 310018 P.R. China
| |
Collapse
|
37
|
Davis N, Heikenfeld J, Milla C, Javey A. The challenges and promise of sweat sensing. Nat Biotechnol 2024; 42:860-871. [PMID: 38212492 DOI: 10.1038/s41587-023-02059-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2023] [Accepted: 11/07/2023] [Indexed: 01/13/2024]
Abstract
The potential of monitoring biomarkers in sweat for health-related applications has spurred rapid growth in the field of wearable sweat sensors over the past decade. Some of the key challenges have been addressed, including measuring sweat-secretion rate and collecting sufficient sample volumes for real-time, continuous molecular analysis without intense exercise. However, except for assessment of cystic fibrosis and regional nerve function, the ability to accurately measure analytes of interest and their physiological relevance to health metrics remain to be determined. Although sweat is not a crystal ball into every aspect of human health, we expect sweat measurements to continue making inroads into niche applications involving active sweating, such as hydration monitoring for athletes and physical laborers and later for medical and casual health monitoring of relevant drugs and hormones.
Collapse
Affiliation(s)
- Noelle Davis
- Electrical Engineering and Computer Sciences, University of California at Berkeley, Berkeley, CA, USA
- Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA, USA
| | - Jason Heikenfeld
- Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, USA.
- Department of Electrical and Computer Engineering, University of Cincinnati, Cincinnati, OH, USA.
| | - Carlos Milla
- The Stanford Cystic Fibrosis Center, Center for Excellence in Pulmonary Biology, Stanford School of Medicine, Palo Alto, CA, USA.
| | - Ali Javey
- Electrical Engineering and Computer Sciences, University of California at Berkeley, Berkeley, CA, USA.
- Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA, USA.
| |
Collapse
|
38
|
Ma S, Wan Z, Wang C, Song Z, Ding Y, Zhang D, Chan CLJ, Shu L, Huang L, Yang Z, Wang F, Bai J, Fan Z, Lin Y. Ultra-Sensitive and Stable Multiplexed Biosensors Array in Fully Printed and Integrated Platforms for Reliable Perspiration Analysis. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2311106. [PMID: 38388858 DOI: 10.1002/adma.202311106] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/23/2023] [Revised: 02/08/2024] [Indexed: 02/24/2024]
Abstract
Electrochemical biosensors have emerged as one of the promising tools for tracking human body physiological dynamics via non-invasive perspiration analysis. However, it remains a key challenge to integrate multiplexed sensors in a highly controllable and reproducible manner to achieve long-term reliable biosensing, especially on flexible platforms. Herein, a fully inkjet printed and integrated multiplexed biosensing patch with remarkably high stability and sensitivity is reported for the first time. These desirable characteristics are enabled by the unique interpenetrating interface design and precise control over active materials mass loading, owing to the optimized ink formulations and droplet-assisted printing processes. The sensors deliver sensitivities of 313.28 µA mm-1 cm-2 for glucose and 0.87 µA mm-1 cm-2 for alcohol sensing with minimal drift over 30 h, which are among the best in the literature. The integrated patch can be used for reliable and wireless diet monitoring or medical intervention via epidermal analysis and would inspire the advances of wearable devices for intelligent healthcare applications.
Collapse
Affiliation(s)
- Suman Ma
- Department of Electronic and Computer Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, 000000, China
- Department of Materials Science and Engineering, Shenzhen Key Laboratory of Full Spectral Solar Electricity Generation (FSSEG), Southern University of Science and Technology, Shenzhen, 518055, China
| | - Zhu'an Wan
- Department of Electronic and Computer Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, 000000, China
| | - Chen Wang
- Department of Electronic and Computer Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, 000000, China
| | - Zhilong Song
- Department of Electronic and Computer Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, 000000, China
- Key Laboratory of Zhenjiang, Institute for Energy Research, Jiangsu University, Zhenjiang, Jiangsu, 212013, China
| | - Yucheng Ding
- Department of Electronic and Computer Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, 000000, China
| | - Daquan Zhang
- Department of Electronic and Computer Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, 000000, China
| | - Chak Lam Jonathan Chan
- Department of Electronic and Computer Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, 000000, China
| | - Lei Shu
- Department of Electronic and Computer Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, 000000, China
| | - Liting Huang
- School of Microelectronics, Southern University of Science and Technology, Shenzhen, 518055, China
| | - Zhensen Yang
- School of Microelectronics, Southern University of Science and Technology, Shenzhen, 518055, China
| | - Fei Wang
- School of Microelectronics, Southern University of Science and Technology, Shenzhen, 518055, China
| | - Jiaming Bai
- Department of Mechanical and Energy Engineering, Southern University of Science and Technology, Shenzhen, 518055, China
| | - Zhiyong Fan
- Department of Electronic and Computer Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, 000000, China
| | - Yuanjing Lin
- School of Microelectronics, Southern University of Science and Technology, Shenzhen, 518055, China
| |
Collapse
|
39
|
Mortazavi SMJ, Zare O, Ghasemi L, Taghizadeh P, Faghani P, Arshadi M, Mortazavi SAR, Sihver L. A Reexamination of Peto's Paradox: Insights Gained from Human Adaptation to Varied Levels of Ionizing and Non-ionizing Radiation. J Biomed Phys Eng 2024; 14:309-314. [PMID: 39027707 PMCID: PMC11252545 DOI: 10.31661/jbpe.v0i0.2402-1729] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2024] [Accepted: 03/27/2024] [Indexed: 07/20/2024]
Abstract
Humans have generally evolved some adaptations to protect against UV and different levels of background ionizing radiation. Similarly, elephants and whales have evolved adaptations to protect against cancer, such as multiple copies of the tumor suppressor gene p53, due to their large size and long lifespan. The difference in cancer protection strategies between humans and elephants/whales depends on genetics, lifestyle, environmental exposures, and evolutionary pressures. In this paper, we discuss how the differences in evolutionary adaptations between humans and elephants could explain why elephants have evolved a protective mechanism against cancer, whereas humans have not. Humans living in regions with high levels of background radiation, e.g. in Ramsar, Iran where exposure rates exceed those on the surface of Mars, seem to have developed some kind of protection against the ionizing radiation. However, humans in general have not developed cancer-fighting adaptations, so they instead rely on medical technologies and interventions. The difference in cancer protection strategies between humans and elephants/whales depends on genetics, lifestyle, environmental exposures, and evolutionary pressures. In this paper, we discuss how the differences in evolutionary adaptations between humans and elephants could explain why elephants have evolved a protective mechanism against cancer, whereas humans have not. Studying elephant adaptations may provide insights into new cancer prevention and treatment strategies for humans, but further research is required to fully understand the evolutionary disparities.
Collapse
Affiliation(s)
- Seyed Mohammad Javad Mortazavi
- Ionizing and Non-Ionizing Radiation Protection Research Center (INIRPRC), Shiraz University of Medical Sciences, Shiraz, Iran
| | - Omid Zare
- Department of Medical Physics and Engineering, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Leyla Ghasemi
- Department of Medical Physics and Engineering, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Parmis Taghizadeh
- School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Parsa Faghani
- Department of Medical Physics and Engineering, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Maryam Arshadi
- Department of Medical Physics and Engineering, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran
| | | | - Lembit Sihver
- Department of Physics, East Carolina University, Greenville, USA
- Royal Military College of Canada, Kingston, ON, Canada
- Department of Radiation Physics, Technische Universität Wien, Atominstitut, Vienna, Austria
| |
Collapse
|
40
|
Merritt JR, Ozga M, De Chavez PJD, Boolani A, Baker LB. No effect of tattoos on local sweat concentrations of select cytokines, cortisol, glucose, blood urea nitrogen, or lactate during exercise. Sci Rep 2024; 14:12570. [PMID: 38821996 PMCID: PMC11143332 DOI: 10.1038/s41598-024-63057-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2024] [Accepted: 05/24/2024] [Indexed: 06/02/2024] Open
Abstract
Due to growing interest in the investigation of exercise induced sweat biomarkers to assess an individual's health and the increasing prevalence of tattoos in the world's population, investigators sought to determine whether local sweat concentrations and excretion rates of epidermal growth factor (EGF), interleukin (IL) -1α, IL-6, IL-8, cortisol, glucose, blood urea nitrogen (BUN), and lactate differ between tattooed and contralateral non-tattooed skin during exercise. Sixteen recreational exercisers [female (50%)] (age = 25-48 years) with ≥ 1 unilateral permanent tattoo [median tattoo age = 6 years, IQR = 5] on the arm/torso completed an outdoor group fitness session. There were no significant differences between tattooed and non-tattooed skin for sweat EGF, IL-1α, IL-8, cortisol, glucose, BUN, or lactate concentrations. There were no significant differences between tattooed and non-tattooed skin for sweat EGF, IL-1α, IL-8, cortisol, glucose, BUN, or lactate excretion rate. Findings suggest that permanent tattoos older than 1 year may not impact local sweat EGF, IL-1α, IL-8, cortisol, glucose, BUN, and lactate concentrations or excretion rates during exercise.Clinical trial identifier NCT04920266 was registered on June 9, 2021.
Collapse
Affiliation(s)
- James R Merritt
- Gatorade Sports Science Institute, PepsiCo R&D, Valhalla, NY, USA.
| | - Michal Ozga
- Gatorade Sports Science Institute, PepsiCo R&D, Valhalla, NY, USA
| | | | - Ali Boolani
- Gatorade Sports Science Institute, PepsiCo R&D, Valhalla, NY, USA
| | - Lindsay B Baker
- Gatorade Sports Science Institute, PepsiCo R&D, Valhalla, NY, USA
| |
Collapse
|
41
|
Quadros LCS, Silva-Lovato CH, Dotto MER, Ribeiro JS, Soto AF, Duque TM, Cuevas-Suárez CE, Coelho SM, Badaró MM. In situ study of the effect of endogenous and exogenous agents on color stability, hardness, and surface roughness of an elastomer for facial prostheses. J Prosthodont 2024. [PMID: 38812246 DOI: 10.1111/jopr.13876] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2023] [Accepted: 05/13/2024] [Indexed: 05/31/2024] Open
Abstract
PURPOSE To evaluate in situ the influence of sweat, oil, sunscreen, and disinfectant solution on the color stability, hardness, and roughness of elastomer for facial prostheses. MATERIALS AND METHODS Standardized and intrinsically pigmented specimens remained in contact with human skin from the same person for 30 days, considering exposures (n = 36 per group), absent of exposition (Control, C); sweat and oiliness contact (SO); sweat and oiliness associated with sunscreen (SOS); 0.12% chlorhexidine digluconate immersion (CD0.12%); and all agents exposed (SOSCD). The main variables were color change (CIELab and National Standard Bureau system, NBS), Shore A hardness, and surface roughness, measured at baseline and 30 days. Qualitative analyses were performed by atomic force microscopy (AFM) and scanning electron microscopy (SEM). The data were analyzed by Kruskal-Wallis tests (color) and two-way ANOVA (hardness and roughness) with Sidak post-test (α = 0.05). RESULTS CD0.12% (1.54 ± 0.49) and SOSCD (2.10 ± 1.03) had similar effects and caused the smallest color changes, considered mild and noticeable (NBS), respectively. SOS promoted the greatest color change (6.99 ± 1.43, NBS: large) and hardness (17.97 ± 0.56); SOS promoted intermediate roughness (3.48 ± 1.05) between SOSCD (2.25 ± 0.53), and two similar groups: C (4.46 ± 0.95), and CD0.12% (4.39 ± 1.26). The qualitative analysis showed an irregular, dense, dry, and whitish layer on the surface of the specimens exposed to sunscreen, which was reduced when in contact with 0.12% chlorhexidine digluconate. CONCLUSIONS Endogenous and exogenous factors are capable of altering elastomer properties. The 0.12% chlorhexidine digluconate minimized the changes caused by sweat, oil, and sunscreen.
Collapse
Affiliation(s)
| | - Cláudia Helena Silva-Lovato
- Department of Dental Materials, Prosthodontics, School of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto, SP, Brazil
| | - Marta Elisa Rosso Dotto
- Department of Physics, Federal University of Santa Catarina (UFSC), Florianópolis, SC, Brazil
| | - Juliana Silva Ribeiro
- Department of Dentistry, Federal University of Santa Catarina (UFSC), Florianópolis, SC, Brazil
| | - Artur Ferronato Soto
- Department of Dentistry, Federal University of Santa Catarina (UFSC), Florianópolis, SC, Brazil
| | - Thais Mageste Duque
- Department of Dentistry, Federal University of Santa Catarina (UFSC), Florianópolis, SC, Brazil
| | - Carlos Enrique Cuevas-Suárez
- Dental Materials Laboratory, Academic Area of Dentistry, Autonomous University of Hidalgo State, Pachuca, Mexico
| | - Sérgio Murilo Coelho
- Department of Dentistry, Federal University of Santa Catarina (UFSC), Florianópolis, SC, Brazil
| | | |
Collapse
|
42
|
Adelaars S, Konings CJAM, Cox L, Boonen E, Mischi M, Bouwman RA, van de Kerkhof D. The correlation of urea and creatinine concentrations in sweat and saliva with plasma during hemodialysis: an observational cohort study. Clin Chem Lab Med 2024; 62:1118-1125. [PMID: 38253354 DOI: 10.1515/cclm-2023-1285] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2023] [Accepted: 01/03/2024] [Indexed: 01/24/2024]
Abstract
OBJECTIVES Urea and creatinine concentrations in plasma are used to guide hemodialysis (HD) in patients with end-stage renal disease (ESRD). To support individualized HD treatment in a home situation, there is a clinical need for a non-invasive and continuous alternative to plasma for biomarker monitoring during and between cycles of HD. In this observational study, we therefore established the correlation of urea and creatinine concentrations between sweat, saliva and plasma in a cohort of ESRD patients on HD. METHODS Forty HD patients were recruited at the Dialysis Department of the Catharina Hospital Eindhoven. Sweat and salivary urea and creatinine concentrations were analyzed at the start and at the end of one HD cycle and compared to the corresponding plasma concentrations. RESULTS A decrease of urea concentrations during HD was observed in sweat, from 27.86 mmol/L to 12.60 mmol/L, and saliva, from 24.70 mmol/L to 5.64 mmol/L. Urea concentrations in sweat and saliva strongly correlated with the concentrations in plasma (ρ 0.92 [p<0.001] and 0.94 [p<0.001], respectively). Creatinine concentrations also decreased in sweat from 43.39 μmol/L to 19.69 μmol/L, and saliva, from 59.00 μmol/L to 13.70 μmol/L. However, for creatinine, correlation coefficients were lower than for urea for both sweat and saliva compared to plasma (ρ: 0.58 [p<0.001] and 0.77 [p<0.001], respectively). CONCLUSIONS The results illustrate a proof of principle of urea measurements in sweat and saliva to monitor HD adequacy in a non-invasive and continuous manner. Biosensors enabling urea monitoring in sweat or saliva could fill in a clinical need to enable at-home HD for more patients and thereby decrease patient burden.
Collapse
Affiliation(s)
- Sophie Adelaars
- Department of Electrical Engineering, Signal Processing Systems, Eindhoven University of Technology, Eindhoven, The Netherlands
- Department of Anesthesiology, Catharina Hospital Eindhoven, Eindhoven, The Netherlands
- Clinical Laboratory, Catharina Hospital Eindhoven, Eindhoven, The Netherlands
| | - Constantijn J A M Konings
- Department Internal Medicine and Kidney Diseases, Catharina Hospital Eindhoven, Eindhoven, The Netherlands
| | - Lieke Cox
- Royal Philips, Eindhoven, The Netherlands
| | - Eva Boonen
- Department of Anesthesiology and Intensive Care Medicine, General Hospital Turnhout, Turnhout, Belgium
| | - Massimo Mischi
- Department of Electrical Engineering, Signal Processing Systems, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - R Arthur Bouwman
- Department of Electrical Engineering, Signal Processing Systems, Eindhoven University of Technology, Eindhoven, The Netherlands
- Department of Anesthesiology, Catharina Hospital Eindhoven, Eindhoven, The Netherlands
| | - Daan van de Kerkhof
- Clinical Laboratory, Catharina Hospital Eindhoven, Eindhoven, The Netherlands
- Department of Biomedical Engineering, Chemical Biology, Eindhoven University of Technology, Eindhoven, The Netherlands
| |
Collapse
|
43
|
Costa FG, Mills KB, Crosby HA, Horswill AR. The Staphylococcus aureus regulatory program in a human skin-like environment. mBio 2024; 15:e0045324. [PMID: 38546267 PMCID: PMC11077960 DOI: 10.1128/mbio.00453-24] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2024] [Accepted: 03/04/2024] [Indexed: 04/09/2024] Open
Abstract
Staphylococcus aureus is a Gram-positive pathogen responsible for the majority of skin and soft tissue infections (SSTIs). S. aureus colonizes the anterior nares of approximately 20%-30% of the population and transiently colonizes the skin, thereby increasing the risk of developing SSTIs and more serious infections. Current laboratory models that mimic the skin surface environment are expensive, require substantial infrastructure, and limit the scope of bacterial physiology studies under human skin conditions. To overcome these limitations, we developed a cost-effective, open-source, chemically defined media recipe termed skin-like medium (SLM) that incorporates key aspects of the human skin surface environment and supports growth of several staphylococcal species. We utilized SLM to investigate the transcriptional response of methicillin-resistant Staphylococcus aureus (MRSA) following growth in SLM compared to a commonly used laboratory media. Through RNA-seq analysis, we observed the upregulation of several virulence factors, including genes encoding functions involved in adhesion, proteolysis, and cytotoxicity. To further explore these findings, we conducted quantitative reverse transcription-PCR (qRT-PCR) experiments to determine the influence of media composition, pH, and temperature on the transcriptional response of key factors involved in adhesion and virulence. We also demonstrated that MRSA primed in SLM adhered better to human corneocytes and demonstrated adhesin-specific phenotypes that previously required genetic manipulation. This improved adherence to corneocytes was dependent on both acidic pH and growth in SLM. These results support the potential utility of SLM as an in vitro model for assessing staphylococcal physiology and metabolism on human skin. IMPORTANCE Staphylococcus aureus is the major cause of skin diseases, and its increased prevalence in skin colonization and infections present a need to understand its physiology in this environment. The work presented here outlines S. aureus upregulation of colonization and virulence factors using a newly developed medium that strives to replicate the human skin surface environment and demonstrates roles for adhesins clumping factor A (ClfA), serine-rich repeat glycoprotein adhesin (SraP), and the fibronectin binding proteins (Fnbps) in human corneocyte adherence.
Collapse
Affiliation(s)
- Flavia G. Costa
- Department of Immunology and Microbiology, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA
| | - Krista B. Mills
- Department of Immunology and Microbiology, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA
| | - Heidi A. Crosby
- Department of Immunology and Microbiology, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA
| | - Alexander R. Horswill
- Department of Immunology and Microbiology, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA
- Department of Veterans Affairs, Eastern Colorado Healthcare System, Aurora, Colorado, USA
| |
Collapse
|
44
|
Dmitrieva NI, Boehm M, Yancey PH, Enhörning S. Long-term health outcomes associated with hydration status. Nat Rev Nephrol 2024; 20:275-294. [PMID: 38409366 DOI: 10.1038/s41581-024-00817-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/31/2024] [Indexed: 02/28/2024]
Abstract
Body water balance is determined by fundamental homeostatic mechanisms that maintain stable volume, osmolality and the composition of extracellular and intracellular fluids. Water balance is maintained by multiple mechanisms that continuously match water losses through urine, the skin, the gastrointestinal tract and respiration with water gains achieved through drinking, eating and metabolic water production. Hydration status is determined by the state of the water balance. Underhydration occurs when a decrease in body water availability, due to high losses or low gains, stimulates adaptive responses within the water balance network that are aimed at decreasing losses and increasing gains. This stimulation is also accompanied by cardiovascular adjustments. Epidemiological and experimental studies have linked markers of low fluid intake and underhydration - such as increased plasma concentration of vasopressin and sodium, as well as elevated urine osmolality - with an increased risk of new-onset chronic diseases, accelerated aging and premature mortality, suggesting that persistent activation of adaptive responses may be detrimental to long-term health outcomes. The causative nature of these associations is currently being tested in interventional trials. Understanding of the physiological responses to underhydration may help to identify possible mechanisms that underlie potential adverse, long-term effects of underhydration and inform future research to develop preventative and treatment approaches to the optimization of hydration status.
Collapse
Affiliation(s)
- Natalia I Dmitrieva
- Laboratory of Cardiovascular Regenerative Medicine, National Heart Lung and Blood Institute, NIH, Bethesda, Maryland, USA.
| | - Manfred Boehm
- Laboratory of Cardiovascular Regenerative Medicine, National Heart Lung and Blood Institute, NIH, Bethesda, Maryland, USA
| | - Paul H Yancey
- Biology Department, Whitman College, Walla Walla, Washington, USA
| | - Sofia Enhörning
- Perinatal and Cardiovascular Epidemiology, Lund University Diabetes Centre, Department of Clinical Sciences in Malmö, Lund University, Malmö, Sweden
- Department of Internal Medicine, Skåne University Hospital, Malmö, Sweden
| |
Collapse
|
45
|
Shi Z, Deng P, Zhou LA, Jin M, Fang F, Chen T, Liu G, Wen H, An Z, Liang H, Lu Y, Liu J, Liu Q. Wireless and battery-free wearable biosensing of riboflavin in sweat for precision nutrition. Biosens Bioelectron 2024; 251:116136. [PMID: 38377637 DOI: 10.1016/j.bios.2024.116136] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2023] [Revised: 02/03/2024] [Accepted: 02/16/2024] [Indexed: 02/22/2024]
Abstract
Nutrition assessment is crucial for dietary guidance and prevention of malnutrition. Recent endeavors in wearable biochemical sensors have enabled real-time, in situ analysis of nutrients in sweat. However, the monitoring of riboflavin, an indispensable vitamin B involved in energy metabolism, remains challenging due to its trace level and variations in the sweat matrix. Herein, we report a wireless, battery-free, and flexible wearable biosensing system for the in situ monitoring of sweat riboflavin. Highly sensitive and selective electrochemical voltammetric detection is realized based on the synergistic effect of electrodeposited reduced graphene oxide (rGO) and platinum nanoparticles (PtNPs) with a low detection limit of 1.2 nM. The fully integrated system is capable of sweat sampling with the microfluidic patch, real-time riboflavin analysis and pH calibration with the flexible electrode array, as well as wirelessly simultaneous near field communication (NFC) energy harvesting and data transmission with the flexible circuit and a smartphone. On-body human sweat analysis demonstrates high accuracy cross-validated with gold-standard measurements, and reveals a strong correlation between sweat and urine riboflavin levels. The proposed wearable platform opens up attractive possibilities for noninvasive nutrient tracking, providing strong potential for personalized dietary guidance towards precision nutrition.
Collapse
Affiliation(s)
- Zhenghan Shi
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, PR China; Taizhou Key Laboratory of Medical Devices and Advanced Materials, Research Institute of Zhejiang University, Taizhou, 318000, PR China
| | - Peixue Deng
- Life Sciences Institute, Guangxi Key Laboratory of AIDS Prevention and Treatment, Guangxi Medical University, Nanning, Guangxi, 530021, PR China
| | - Li-Ang Zhou
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, PR China
| | - Meng Jin
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, PR China
| | - Feiyue Fang
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, PR China
| | - Tao Chen
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, PR China
| | - Guang Liu
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, PR China
| | - Hao Wen
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, PR China
| | - Zijian An
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, PR China
| | - Hao Liang
- Life Sciences Institute, Guangxi Key Laboratory of AIDS Prevention and Treatment, Guangxi Medical University, Nanning, Guangxi, 530021, PR China
| | - Yanli Lu
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, PR China
| | - Jun Liu
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, PR China; Taizhou Key Laboratory of Medical Devices and Advanced Materials, Research Institute of Zhejiang University, Taizhou, 318000, PR China
| | - Qingjun Liu
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, PR China; Taizhou Key Laboratory of Medical Devices and Advanced Materials, Research Institute of Zhejiang University, Taizhou, 318000, PR China.
| |
Collapse
|
46
|
Bocu R. Extended Review Concerning the Integration of Electrochemical Biosensors into Modern IoT and Wearable Devices. BIOSENSORS 2024; 14:214. [PMID: 38785688 PMCID: PMC11117989 DOI: 10.3390/bios14050214] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/28/2024] [Revised: 04/17/2024] [Accepted: 04/23/2024] [Indexed: 05/25/2024]
Abstract
Electrochemical biosensors include a recognition component and an electronic transducer, which detect the body fluids with a high degree of accuracy. More importantly, they generate timely readings of the related physiological parameters, and they are suitable for integration into portable, wearable and implantable devices that are significant relative to point-of-care diagnostics scenarios. As an example, the personal glucose meter fundamentally improves the management of diabetes in the comfort of the patients' homes. This review paper analyzes the principles of electrochemical biosensing and the structural features of electrochemical biosensors relative to the implementation of health monitoring and disease diagnostics strategies. The analysis particularly considers the integration of the biosensors into wearable, portable, and implantable systems. The fundamental aim of this paper is to present and critically evaluate the identified significant developments in the scope of electrochemical biosensing for preventive and customized point-of-care diagnostic devices. The paper also approaches the most important engineering challenges that should be addressed in order to improve the sensing accuracy, and enable multiplexing and one-step processes, which mediate the integration of electrochemical biosensing devices into digital healthcare scenarios.
Collapse
Affiliation(s)
- Razvan Bocu
- Department of Mathematics and Computer Science, Transilvania University of Brasov, 500036 Brasov, Romania
| |
Collapse
|
47
|
Zonnefeld AG, Cui CY, Tsitsipatis D, Piao Y, Fan J, Mazan-Mamczarz K, Xue Y, Indig FE, De S, Gorospe M. Characterization of age-associated gene expression changes in mouse sweat glands. Aging (Albany NY) 2024; 16:6717-6730. [PMID: 38637019 PMCID: PMC11087089 DOI: 10.18632/aging.205776] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Accepted: 03/18/2024] [Indexed: 04/20/2024]
Abstract
Evaporation of sweat on the skin surface is the major mechanism for dissipating heat in humans. The secretory capacity of sweat glands (SWGs) declines during aging, leading to heat intolerance in the elderly, but the mechanisms responsible for this decline are poorly understood. We investigated the molecular changes accompanying SWG aging in mice, where sweat tests confirmed a significant reduction of active SWGs in old mice relative to young mice. We first identified SWG-enriched mRNAs by comparing the skin transcriptome of Eda mutant Tabby male mice, which lack SWGs, with that of wild-type control mice by RNA-sequencing analysis. This comparison revealed 171 mRNAs enriched in SWGs, including 47 mRNAs encoding 'core secretory' proteins such as transcription factors, ion channels, ion transporters, and trans-synaptic signaling proteins. Among these, 28 SWG-enriched mRNAs showed significantly altered abundance in the aged male footpad skin, and 11 of them, including Foxa1, Best2, Chrm3, and Foxc1 mRNAs, were found in the 'core secretory' category. Consistent with the changes in mRNA expression levels, immunohistology revealed that higher numbers of secretory cells from old SWGs express the transcription factor FOXC1, the protein product of Foxc1 mRNA. In sum, our study identified mRNAs enriched in SWGs, including those that encode core secretory proteins, and altered abundance of these mRNAs and proteins with aging in mouse SWGs.
Collapse
Affiliation(s)
- Alexandra G. Zonnefeld
- Laboratory of Genetics and Genomics, National Institute on Aging Intramural Research Program, National Institutes of Health, Baltimore, MD 21224, USA
| | - Chang-Yi Cui
- Laboratory of Genetics and Genomics, National Institute on Aging Intramural Research Program, National Institutes of Health, Baltimore, MD 21224, USA
| | - Dimitrios Tsitsipatis
- Laboratory of Genetics and Genomics, National Institute on Aging Intramural Research Program, National Institutes of Health, Baltimore, MD 21224, USA
| | - Yulan Piao
- Laboratory of Genetics and Genomics, National Institute on Aging Intramural Research Program, National Institutes of Health, Baltimore, MD 21224, USA
| | - Jinshui Fan
- Laboratory of Genetics and Genomics, National Institute on Aging Intramural Research Program, National Institutes of Health, Baltimore, MD 21224, USA
| | - Krystyna Mazan-Mamczarz
- Laboratory of Genetics and Genomics, National Institute on Aging Intramural Research Program, National Institutes of Health, Baltimore, MD 21224, USA
| | - Yutong Xue
- Laboratory of Genetics and Genomics, National Institute on Aging Intramural Research Program, National Institutes of Health, Baltimore, MD 21224, USA
| | - Fred E. Indig
- Confocal Imaging Core Facility, National Institute on Aging Intramural Research Program, National Institutes of Health, Baltimore, MD 21224, USA
| | - Supriyo De
- Laboratory of Genetics and Genomics, National Institute on Aging Intramural Research Program, National Institutes of Health, Baltimore, MD 21224, USA
| | - Myriam Gorospe
- Laboratory of Genetics and Genomics, National Institute on Aging Intramural Research Program, National Institutes of Health, Baltimore, MD 21224, USA
| |
Collapse
|
48
|
Joutsen A, Cömert A, Kaappa E, Vanhatalo K, Riistama J, Vehkaoja A, Eskola H. ECG signal quality in intermittent long-term dry electrode recordings with controlled motion artifacts. Sci Rep 2024; 14:8882. [PMID: 38632263 PMCID: PMC11024137 DOI: 10.1038/s41598-024-56595-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Accepted: 03/08/2024] [Indexed: 04/19/2024] Open
Abstract
Wearable long-term monitoring applications are becoming more and more popular in both the consumer and the medical market. In wearable ECG monitoring, the data quality depends on the properties of the electrodes and on how they interface with the skin. Dry electrodes do not require any action from the user. They usually do not irritate the skin, and they provide sufficiently high-quality data for ECG monitoring purposes during low-intensity user activity. We investigated prospective motion artifact-resistant dry electrode materials for wearable ECG monitoring. The tested materials were (1) porous: conductive polymer, conductive silver fabric; and (2) solid: stainless steel, silver, and platinum. ECG was acquired from test subjects in a 10-min continuous settling test and in a 48-h intermittent long-term test. In the settling test, the electrodes were stationary, whereas both stationary and controlled motion artifact tests were included in the long-term test. The signal-to-noise ratio (SNR) was used as the figure of merit to quantify the results. Skin-electrode interface impedance was measured to quantify its effect on the ECG, as well as to leverage the dry electrode ECG amplifier design. The SNR of all electrode types increased during the settling test. In the long-term test, the SNR was generally elevated further. The introduction of electrode movement reduced the SNR markedly. Solid electrodes had a higher SNR and lower skin-electrode impedance than porous electrodes. In the stationary testing, stainless steel showed the highest SNR, followed by platinum, silver, conductive polymer, and conductive fabric. In the movement testing, the order was platinum, stainless steel, silver, conductive polymer, and conductive fabric.
Collapse
Affiliation(s)
- Atte Joutsen
- Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland.
- Finnish Cardiovascular Research Center, Tampere, Finland.
- Department of Medical Physics, Tampere University Hospital, Tampere, Finland.
| | - Alper Cömert
- Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
| | - Emma Kaappa
- Faculty of Engineering and Natural Sciences, Tampere University, Tampere, Finland
| | - Kirsi Vanhatalo
- Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
| | | | - Antti Vehkaoja
- Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
- Finnish Cardiovascular Research Center, Tampere, Finland
| | - Hannu Eskola
- Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
| |
Collapse
|
49
|
Joutsen J, Pessa JC, Jokelainen O, Sironen R, Hartikainen JM, Sistonen L. Comprehensive analysis of human tissues reveals unique expression and localization patterns of HSF1 and HSF2. Cell Stress Chaperones 2024; 29:235-271. [PMID: 38458311 PMCID: PMC10963207 DOI: 10.1016/j.cstres.2024.03.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2024] [Revised: 02/29/2024] [Accepted: 03/01/2024] [Indexed: 03/10/2024] Open
Abstract
Heat shock factors (HSFs) are the main transcriptional regulators of the evolutionarily conserved heat shock response. Beyond cell stress, several studies have demonstrated that HSFs also contribute to a vast variety of human pathologies, ranging from metabolic diseases to cancer and neurodegeneration. Despite their evident role in mitigating cellular perturbations, the functions of HSF1 and HSF2 in physiological proteostasis have remained inconclusive. Here, we analyzed a comprehensive selection of paraffin-embedded human tissue samples with immunohistochemistry. We demonstrate that both HSF1 and HSF2 display distinct expression and subcellular localization patterns in benign tissues. HSF1 localizes to the nucleus in all epithelial cell types, whereas nuclear expression of HSF2 was limited to only a few cell types, especially the spermatogonia and the urothelial umbrella cells. We observed a consistent and robust cytoplasmic expression of HSF2 across all studied smooth muscle and endothelial cells, including the smooth muscle cells surrounding the vasculature and the high endothelial venules in lymph nodes. Outstandingly, HSF2 localized specifically at cell-cell adhesion sites in a broad selection of tissue types, such as the cardiac muscle, liver, and epididymis. To the best of our knowledge, this is the first study to systematically describe the expression and localization patterns of HSF1 and HSF2 in benign human tissues. Thus, our work expands the biological landscape of these factors and creates the foundation for the identification of specific roles of HSF1 and HSF2 in normal physiological processes.
Collapse
Affiliation(s)
- Jenny Joutsen
- Department of Pathology, Lapland Central Hospital, Lapland Wellbeing Services County, Rovaniemi, Finland.
| | - Jenny C Pessa
- Faculty of Science and Engineering, Cell Biology, Åbo Akademi University, Turku, Finland; Turku Bioscience Centre, University of Turku and Åbo Akademi University, Turku, Finland
| | - Otto Jokelainen
- Institute of Clinical Medicine, Clinical Pathology and Forensic Medicine, and Cancer RC, University of Eastern Finland, Kuopio, Finland; Department of Clinical Pathology, Kuopio University Hospital, Kuopio, Finland
| | - Reijo Sironen
- Institute of Clinical Medicine, Clinical Pathology and Forensic Medicine, and Cancer RC, University of Eastern Finland, Kuopio, Finland; Department of Clinical Pathology, Kuopio University Hospital, Kuopio, Finland
| | - Jaana M Hartikainen
- Institute of Clinical Medicine, Clinical Pathology and Forensic Medicine, and Cancer RC, University of Eastern Finland, Kuopio, Finland
| | - Lea Sistonen
- Faculty of Science and Engineering, Cell Biology, Åbo Akademi University, Turku, Finland; Turku Bioscience Centre, University of Turku and Åbo Akademi University, Turku, Finland.
| |
Collapse
|
50
|
Loukelis K, Koutsomarkos N, Mikos AG, Chatzinikolaidou M. Advances in 3D bioprinting for regenerative medicine applications. Regen Biomater 2024; 11:rbae033. [PMID: 38845855 PMCID: PMC11153344 DOI: 10.1093/rb/rbae033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2023] [Revised: 03/13/2024] [Accepted: 03/17/2024] [Indexed: 06/09/2024] Open
Abstract
Biofabrication techniques allow for the construction of biocompatible and biofunctional structures composed from biomaterials, cells and biomolecules. Bioprinting is an emerging 3D printing method which utilizes biomaterial-based mixtures with cells and other biological constituents into printable suspensions known as bioinks. Coupled with automated design protocols and based on different modes for droplet deposition, 3D bioprinters are able to fabricate hydrogel-based objects with specific architecture and geometrical properties, providing the necessary environment that promotes cell growth and directs cell differentiation towards application-related lineages. For the preparation of such bioinks, various water-soluble biomaterials have been employed, including natural and synthetic biopolymers, and inorganic materials. Bioprinted constructs are considered to be one of the most promising avenues in regenerative medicine due to their native organ biomimicry. For a successful application, the bioprinted constructs should meet particular criteria such as optimal biological response, mechanical properties similar to the target tissue, high levels of reproducibility and printing fidelity, but also increased upscaling capability. In this review, we highlight the most recent advances in bioprinting, focusing on the regeneration of various tissues including bone, cartilage, cardiovascular, neural, skin and other organs such as liver, kidney, pancreas and lungs. We discuss the rapidly developing co-culture bioprinting systems used to resemble the complexity of tissues and organs and the crosstalk between various cell populations towards regeneration. Moreover, we report on the basic physical principles governing 3D bioprinting, and the ideal bioink properties based on the biomaterials' regenerative potential. We examine and critically discuss the present status of 3D bioprinting regarding its applicability and current limitations that need to be overcome to establish it at the forefront of artificial organ production and transplantation.
Collapse
Affiliation(s)
- Konstantinos Loukelis
- Department of Materials Science and Technology, University of Crete, Heraklion 70013, Greece
| | - Nikos Koutsomarkos
- Department of Materials Science and Technology, University of Crete, Heraklion 70013, Greece
| | - Antonios G Mikos
- Department of Bioengineering, Rice University, Houston, TX 77030, USA
| | - Maria Chatzinikolaidou
- Department of Materials Science and Technology, University of Crete, Heraklion 70013, Greece
- Institute of Electronic Structure and Laser (IESL), Foundation for Research and Technology Hellas (FORTH), Heraklion 70013, Greece
| |
Collapse
|