101
|
Zu K, Liu X, Shi L, Tao G, Loftus CT, Lange S, Goodman JE. Concentration-response of short-term ozone exposure and hospital admissions for asthma in Texas. ENVIRONMENT INTERNATIONAL 2017; 104:139-145. [PMID: 28434561 DOI: 10.1016/j.envint.2017.04.006] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/17/2017] [Revised: 03/31/2017] [Accepted: 04/13/2017] [Indexed: 06/07/2023]
Abstract
BACKGROUND Short-term exposure to ozone has been associated with asthma hospital admissions (HA) and emergency department (ED) visits, but the shape of the concentration-response (C-R) curve is unclear. METHODS We conducted a time series analysis of asthma HAs and ambient ozone concentrations in six metropolitan areas in Texas from 2001 to 2013. Using generalized linear regression models, we estimated the effect of daily 8-hour maximum ozone concentrations on asthma HAs for all ages combined, and for those aged 5-14, 15-64, and 65+years. We fit penalized regression splines to evaluate the shape of the C-R curves. RESULTS Using a log-linear model, estimated risk per 10ppb increase in average daily 8-hour maximum ozone concentrations was highest for children (relative risk [RR]=1.047, 95% confidence interval [CI]: 1.025-1.069), lower for younger adults (RR=1.018, 95% CI: 1.005-1.032), and null for older adults (RR=1.002, 95% CI: 0.981-1.023). However, penalized spline models demonstrated significant nonlinear C-R relationships for all ages combined, children, and younger adults, indicating the existence of thresholds. We did not observe an increased risk of asthma HAs until average daily 8-hour maximum ozone concentrations exceeded approximately 40ppb. CONCLUSION Ozone and asthma HAs are significantly associated with each other; susceptibility to ozone is age-dependent, with children at highest risk. C-R relationships between average daily 8-hour maximum ozone concentrations and asthma HAs are significantly curvilinear for all ages combined, children, and younger adults. These nonlinear relationships, as well as the lack of relationship between average daily 8-hour maximum and peak ozone concentrations, have important implications for assessing risks to human health in regulatory settings.
Collapse
Affiliation(s)
- Ke Zu
- Gradient, 20 University Road, Cambridge, MA, United States
| | - Xiaobin Liu
- Gradient, 20 University Road, Cambridge, MA, United States
| | - Liuhua Shi
- Gradient, 20 University Road, Cambridge, MA, United States
| | - Ge Tao
- Gradient, 20 University Road, Cambridge, MA, United States
| | | | - Sabine Lange
- Texas Commission on Environmental Quality, 12100 Park 35 Circle, Austin, TX, United States
| | | |
Collapse
|
102
|
Darling E, Corsi RL. Field-to-laboratory analysis of clay wall coatings as passive removal materials for ozone in buildings. INDOOR AIR 2017; 27:658-669. [PMID: 27859627 DOI: 10.1111/ina.12345] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/11/2016] [Accepted: 10/07/2016] [Indexed: 06/06/2023]
Abstract
Ozone reacts readily with many indoor materials, as well as with compounds in indoor air. These reactions lead to lower indoor than outdoor ozone concentrations when outdoor air is the major contributor to indoor ozone. However, the products of indoor ozone reactions may be irritating or harmful to building occupants. While active technologies exist to reduce indoor ozone concentrations (i.e, in-duct filtration using activated carbon), they can be cost-prohibitive for some and/or infeasible for dwellings that do not have heating, ventilating, and air-conditioning systems. In this study, the potential for passive reduction of indoor ozone by two different clay-based interior surface coatings was explored. These coatings were exposed to occupied residential indoor environments and tested bimonthly in environmental chambers for quantification of ozone reaction probabilities and reaction product emission rates over a 6-month period. Results indicate that clay-based coatings may be effective as passive removal materials, with relatively low by-product emission rates that decay rapidly within 2 months.
Collapse
Affiliation(s)
- E Darling
- Department of Civil, Architectural and Environmental Engineering, Cockrell School of Engineering, The University of Texas at Austin, Austin, TX, USA
| | - R L Corsi
- Department of Civil, Architectural and Environmental Engineering, Cockrell School of Engineering, The University of Texas at Austin, Austin, TX, USA
| |
Collapse
|
103
|
Wang CM, Barratt B, Carslaw N, Doutsi A, Dunmore RE, Ward MW, Lewis AC. Unexpectedly high concentrations of monoterpenes in a study of UK homes. ENVIRONMENTAL SCIENCE. PROCESSES & IMPACTS 2017; 19:528-537. [PMID: 28224154 DOI: 10.1039/c6em00569a] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
The abundance of volatile organic compounds (VOCs) found in homes depends on many factors such as emissions, ventilation and the oxidative environment and these are evolving over time, reflecting changes in chemical use, behaviour and building design/materials. The concentrations of VOCs in 25 UK homes of varying ages, design and occupancy were quantified using continuous indoor air sampling over five days. Air was collected through low flow (1 mL min-1) constant flow restrictors into evacuated 6 L internally silica-treated canisters until the canisters reached atmospheric pressure. This was followed by thermal desorption-gas chromatography and high mass accuracy time-of-flight mass spectrometry (TD-GC-TOF/MS). A fully quantitative analysis was performed on the eight most abundant hydrocarbon-based VOCs found. Despite differences in building characteristics and occupant numbers 94% of the homes had d-limonene or α-pinene as the most abundant VOCs. The variability seen across the 25 homes in concentrations of monoterpenes indoors was considerably greater than that of species such as isoprene, benzene, toluene and xylenes. The variance in VOCs indoors appeared to be strongly influenced by occupant activities such as cleaning with 5-day average concentrations of d-limonene ranging from 18 μg m-3 to over 1400 μg m-3, a peak domestic value that is possibly the highest yet reported in the literature.
Collapse
|
104
|
Kuo SC, Tsai YI. Emission characteristics of allergenic terpenols in PM 2.5 released from incense burning and the effect of light on the emissions. THE SCIENCE OF THE TOTAL ENVIRONMENT 2017; 584-585:495-504. [PMID: 28131447 DOI: 10.1016/j.scitotenv.2017.01.052] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/19/2016] [Revised: 01/01/2017] [Accepted: 01/09/2017] [Indexed: 06/06/2023]
Abstract
This study investigated allergenic terpenol compounds in incense powder and smoke. The powder of two Thai brands contained higher concentrations of terpenols up to 6.15 times higher than those of two Taiwanese brands. Consequently, Thai incense makers face a higher potential risk of contact dermatitis than Taiwanese incense makers do. d-Limonene was the primary terpenol compound in the powder of Thai B (64.0%) and Thai Y (31.5%), sold in Thailand. By contrast, anisyl alcohol was the primary terpenol compound in the powder of LST (40.3%) and SC (37.7%), sold in Taiwan. After the four brands of incense were ignited, their mean PM2.5 emission factor was 18.02±6.20mgg-1 incense. The PM2.5 mass emission factors of the Taiwanese brands were far higher than those of the Thai brands, and so were the PM2.5 terpenol emission factors, showing that the smokes of the Taiwanese incense were potentially more allergenic than those of the Thai incense. Geraniol, the most allergenic terpenol compound, was 2.8%-10.7% of total terpenol compounds in the powder of the four brands, yet was the main contributor to PM2.5, constituting 66.3%-83.5% of terpenol compounds in the smokes of the four brands. Furthermore, geraniol exhibited an IP ratio, defined as the incense/powder (IP) ratio of terpenol-related species, >1 in all four brands, and >5 in the Taiwanese brands, suggesting a greater health risk with the smoke from the Taiwanese incense. The IP ratios of other terpenol species were all <1, indicating decomposition through combustion. Additionally, the light/darkroom ratios of the terpenol species were >1, meaning that the generation of PM2.5 terpenol compounds was potentially enhanced by indoor lighting.
Collapse
Affiliation(s)
- Su-Ching Kuo
- Department of Medicinal Chemistry, Chia Nan University of Pharmacy and Science, 60, Sec. 1, Erren Rd., Rende Dist., Tainan City 71710, Taiwan
| | - Ying I Tsai
- Department of Environmental Engineering and Science, Chia Nan University of Pharmacy and Science, 60, Sec. 1, Erren Rd., Rende Dist., Tainan City 71710, Taiwan; Indoor Air Quality Research and Service Center, Chia Nan University of Pharmacy and Science, 60, Sec. 1, Erren Rd., Rende Dist., Tainan City 71710, Taiwan.
| |
Collapse
|
105
|
Symptoms from masked acrolein exposure suggest altered trigeminal reactivity in chemical intolerance. Neurotoxicology 2017; 60:92-98. [PMID: 28359837 DOI: 10.1016/j.neuro.2017.03.007] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2016] [Revised: 03/22/2017] [Accepted: 03/23/2017] [Indexed: 11/30/2022]
Abstract
BACKGROUND Chemical intolerance (CI) is a widespread occupational and public health problem characterized by symptoms that reportedly result from low-levels of chemical exposure. The mechanisms behind CI are unknown, however modifications of the chemical senses (rather than toxic processes) have been suggested as key components. The aim of this study was to investigate whether individuals with self-reported CI report more sensory irritation during masked acrolein exposure compared to controls without CI. METHODS Individuals with CI (n=18) and controls without CI (n=19) were exposed in an exposure chamber. Each participant took part in two exposure conditions - one with heptane (the masking compound), and one with heptane and acrolein at a dose below previously reported sensory irritation thresholds. The exposures lasted for 60min. Symptoms and confidence ratings were measured continuously throughout the exposure as were measurements of electrodermal activity and self-reported tear-film break-up time. Participants were blind to exposure condition. RESULTS Individuals with CI, compared with controls reported greater sensory irritation in the eyes, nose and throat when exposed to acrolein masked with heptane. There was no difference during exposure to heptane. CONCLUSIONS Masked exposure to acrolein at a concentration below the previously reported detection threshold is perceived as more irritating by individuals with CI compared with controls. The results indicate that there is altered trigeminal reactivity in those with CI compared to controls.
Collapse
|
106
|
Mandin C, Trantallidi M, Cattaneo A, Canha N, Mihucz VG, Szigeti T, Mabilia R, Perreca E, Spinazzè A, Fossati S, De Kluizenaar Y, Cornelissen E, Sakellaris I, Saraga D, Hänninen O, De Oliveira Fernandes E, Ventura G, Wolkoff P, Carrer P, Bartzis J. Assessment of indoor air quality in office buildings across Europe - The OFFICAIR study. THE SCIENCE OF THE TOTAL ENVIRONMENT 2017; 579:169-178. [PMID: 27866741 DOI: 10.1016/j.scitotenv.2016.10.238] [Citation(s) in RCA: 62] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2016] [Revised: 09/27/2016] [Accepted: 10/25/2016] [Indexed: 05/27/2023]
Abstract
The European project OFFICAIR aimed to broaden the existing knowledge regarding indoor air quality (IAQ) in modern office buildings, i.e., recently built or refurbished buildings. Thirty-seven office buildings participated in the summer campaign (2012), and thirty-five participated in the winter campaign (2012-2013). Four rooms were investigated per building. The target pollutants were twelve volatile organic compounds, seven aldehydes, ozone, nitrogen dioxide and particulate matter with aerodynamic diameter <2.5μm (PM2.5). Compared to other studies in office buildings, the benzene, toluene, ethylbenzene, and xylene concentrations were lower in OFFICAIR buildings, while the α-pinene and d-limonene concentrations were higher, and the aldehyde, nitrogen dioxide and PM2.5 concentrations were of the same order of magnitude. When comparing summer and winter, significantly higher concentrations were measured in summer for formaldehyde and ozone, and in winter for benzene, α-pinene, d-limonene, and nitrogen dioxide. The terpene and 2-ethylhexanol concentrations showed heterogeneity within buildings regardless of the season. Considering the average of the summer and winter concentrations, the acetaldehyde and hexanal concentrations tended to increase by 4-5% on average with every floor level increase, and the nitrogen dioxide concentration tended to decrease by 3% on average with every floor level increase. A preliminary evaluation of IAQ in terms of potential irritative and respiratory health effects was performed. The 5-day median and maximum indoor air concentrations of formaldehyde and ozone did not exceed their respective WHO air quality guidelines, and those of acrolein, α-pinene, and d-limonene were lower than their estimated thresholds for irritative and respiratory effects. PM2.5 indoor concentrations were higher than the 24-h and annual WHO ambient air quality guidelines.
Collapse
Affiliation(s)
- Corinne Mandin
- Scientific and Technical Centre for Building (CSTB), Marne-la-Vallée, France.
| | | | | | - Nuno Canha
- Scientific and Technical Centre for Building (CSTB), Marne-la-Vallée, France
| | | | | | - Rosanna Mabilia
- National Research Council, Institute of Atmospheric Pollution Research, Rome, Italy
| | - Erica Perreca
- National Research Council, Institute of Atmospheric Pollution Research, Rome, Italy
| | | | | | - Yvonne De Kluizenaar
- The Netherlands Organization for Applied Scientific Research (TNO), Delft, The Netherlands
| | - Eric Cornelissen
- The Netherlands Organization for Applied Scientific Research (TNO), Delft, The Netherlands
| | | | | | - Otto Hänninen
- National Institute for Health and Welfare (THL), Kuopio, Finland
| | | | - Gabriela Ventura
- Institute of Science and Innovation in Mechanical Engineering and Industrial Management (INEGI), Porto, Portugal
| | - Peder Wolkoff
- National Research Centre for the Working Environment, Copenhagen, Denmark
| | | | | |
Collapse
|
107
|
Niu X, Ho SSH, Ho KF, Huang Y, Cao J, Shen Z, Sun J, Wang X, Wang Y, Lee S, Huang R. Indoor secondary organic aerosols formation from ozonolysis of monoterpene: An example of d-limonene with ammonia and potential impacts on pulmonary inflammations. THE SCIENCE OF THE TOTAL ENVIRONMENT 2017; 579:212-220. [PMID: 27842959 DOI: 10.1016/j.scitotenv.2016.11.018] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/09/2016] [Revised: 11/02/2016] [Accepted: 11/03/2016] [Indexed: 06/06/2023]
Abstract
Monoterpene is one class of biogenic volatile organic compounds (BVOCs) which widely presents in household cleaning products and air fresheners. It plays reactive role in secondary organic aerosols (SOAs) formation with ozone (O3) in indoor environments. Such ozonolysis can be influenced by the presence of gaseous pollutants such as ammonia (NH3). This study focuses on investigations of ozone-initiated formation of indoor SOAs with d-limonene, one of the most abundant indoor monoterpenes, in a large environmental chamber. The maximum total particle number concentration from the ozonolysis in the presence of NH3 was 60% higher than that in the absence of NH3. Both of the nuclei coagulation and condensation involve in the SOAs growth. The potential risks of pulmonary injury for the exposure to the secondary particles formed were presented with the indexes of tumor necrosis factor-α (TNF-α), interleukin-6 (IL-6) and interleukin-10 (IL-10) expression levels in bronchoalveolar lavage fluid (BALF) upon intratracheal instillation in mice lung for 6 and 12h. The results indicated that there was 22-39% stronger pulmonary inflammatory effect on the particles generated with NH3. This is a pilot study which demonstrates the toxicities of the indoor SOAs formed from the ozonolysis of a monoterpene.
Collapse
Affiliation(s)
- Xinyi Niu
- School of Human Settlements and Civil Engineering, , Xi'an Jiaotong University, Xi'an, China; Key Lab of Aerosol Chemistry & Physics, Institute of Earth Environment, Chinese Academy of Sciences, Xi'an, China
| | - Steven Sai Hang Ho
- Key Lab of Aerosol Chemistry & Physics, Institute of Earth Environment, Chinese Academy of Sciences, Xi'an, China; Division of Atmosphere Sciences, Desert Research Institute, Reno, NV89512, United States
| | - Kin Fai Ho
- The Jockey Club School of Public Health and Primary Care, The Chinese University of Hong Kong, Hong Kong, China
| | - Yu Huang
- Key Lab of Aerosol Chemistry & Physics, Institute of Earth Environment, Chinese Academy of Sciences, Xi'an, China; State Key Lab of Loess and Quaternary Geology (SKLLQG), Institute of Earth Environment, Chinese Academy of Sciences, Xi'an 710061, China.
| | - Junji Cao
- Key Lab of Aerosol Chemistry & Physics, Institute of Earth Environment, Chinese Academy of Sciences, Xi'an, China; State Key Lab of Loess and Quaternary Geology (SKLLQG), Institute of Earth Environment, Chinese Academy of Sciences, Xi'an 710061, China; Institute of Global Environmental Change, Xi'an Jiaotong University, Xi'an, China.
| | - Zhenxing Shen
- Department of Environmental Sciences and Engineering, Xi'an Jiaotong University, Xi'an, China
| | - Jian Sun
- Department of Environmental Sciences and Engineering, Xi'an Jiaotong University, Xi'an, China
| | - Xiumei Wang
- School of Pharmacy, Xi'an Jiaotong University, Xi'an, China
| | - Yu Wang
- School of Pharmacy, Xi'an Jiaotong University, Xi'an, China
| | - Shuncheng Lee
- Department of Civil and Structural Engineering, Research Center for Environmental Technology and Management, The Hong Kong Polytechnic University, Hong Kong, China
| | - Rujin Huang
- Key Lab of Aerosol Chemistry & Physics, Institute of Earth Environment, Chinese Academy of Sciences, Xi'an, China; State Key Lab of Loess and Quaternary Geology (SKLLQG), Institute of Earth Environment, Chinese Academy of Sciences, Xi'an 710061, China
| |
Collapse
|
108
|
Jacob P, Benowitz NL, Destaillats H, Gundel L, Hang B, Martins-Green M, Matt GE, Quintana PJE, Samet JM, Schick SF, Talbot P, Aquilina NJ, Hovell MF, Mao JH, Whitehead TP. Thirdhand Smoke: New Evidence, Challenges, and Future Directions. Chem Res Toxicol 2017; 30:270-294. [PMID: 28001376 PMCID: PMC5501723 DOI: 10.1021/acs.chemrestox.6b00343] [Citation(s) in RCA: 153] [Impact Index Per Article: 21.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Thirdhand smoke (THS) is the contamination that persists after secondhand tobacco smoke has been emitted into air. It refers to the tobacco-related gases and particles that become embedded in materials, such as the carpet, walls, furniture, blankets, and toys. THS is not strictly smoke, but chemicals that adhere to surfaces from which they can be released back into the air, undergo chemical transformations and/or accumulate. Currently, the hazards of THS are not as well documented as the hazards of secondhand smoke (SHS). In this Perspective, we describe the distribution and chemical changes that occur as SHS is transformed into THS, studies of environmental contamination by THS, human exposure studies, toxicology studies using animal models and in vitro systems, possible approaches for avoiding exposure, remediation of THS contamination, and priorities for further research.
Collapse
Affiliation(s)
- Peyton Jacob
- Division of Clinical Pharmacology and Experimental herapeutics, Departments of Psychiatry and Medicine, University of California, San Francisco, California 94143, United States
| | - Neal L. Benowitz
- Division of Clinical Pharmacology and Experimental Therapeutics, Medical Service, Departments of Medicine, and Bioengineering & Therapeutic Sciences, University of California, San Francisco, California 94143, United States
- Center for Tobacco Control Research and Education, University of California, San Francisco, California 94143, United States
| | - Hugo Destaillats
- Indoor Environment Group, Lawrence Berkeley National Laboratory, Berkeley, California 94720, United States
| | - Lara Gundel
- Indoor Environment Group, Lawrence Berkeley National Laboratory, Berkeley, California 94720, United States
| | - Bo Hang
- Biological Systems & Engineering, Lawrence Berkeley National Laboratory, Berkeley, California 94720, United States
| | - Manuela Martins-Green
- Department of Cell Biology and Neuroscience, University of California Riverside 92521, United States
| | - Georg E. Matt
- Department of Psychology, San Diego State University, San Diego, California 92182, United States
| | - Penelope J. E. Quintana
- Graduate School of Public Health, San Diego State University, San Diego, California 92182, United States
| | - Jonathan M. Samet
- Department of Preventive Medicine, The Keck School of Medicine, University of Southern California, Los Angeles, California, 90089, United States
| | - Suzaynn F. Schick
- Division of Occupational and Environmental Medicine, School of Medicine, University of California, San Francisco, California 94143, United States
| | - Prue Talbot
- Department of Cell Biology and Neuroscience, University of California Riverside 92521, United States
| | - Noel J. Aquilina
- Department of Geosciences, University of Malta, Msida, MSD 2080, Malta
| | - Melbourne F. Hovell
- Graduate School of Public Health, San Diego State University, San Diego, California 92182, United States
| | - Jian-Hua Mao
- Biological Systems & Engineering, Lawrence Berkeley National Laboratory, Berkeley, California 94720, United States
| | - Todd P. Whitehead
- The Center or Integrative Research on Childhood Leukemia and the Environment, School of Public Health, University of California, Berkeley, 94704, United States
| |
Collapse
|
109
|
Shen J, Chen J, Zhang X, Zou S, Gao Z. Outdoor and Indoor Ozone Concentration Estimation Based on Artificial Neural Network and Single Zone Mass Balance Model. ACTA ACUST UNITED AC 2017. [DOI: 10.1016/j.proeng.2017.10.253] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
110
|
Yang Y, Waring MS. Secondary organic aerosol formation initiated by α-terpineol ozonolysis in indoor air. INDOOR AIR 2016; 26:939-952. [PMID: 26609907 DOI: 10.1111/ina.12271] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/15/2015] [Accepted: 11/18/2015] [Indexed: 06/05/2023]
Abstract
Secondary organic aerosol (SOA) owing to reactive organic gas (ROG) ozonolysis can be an important indoor particle source. However, SOA formation owing to ozonolysis of α-terpineol, which is emitted by consumer product usage and reacts strongly with ozone, has not been systematically quantified. Therefore, we conducted 21 experiments to investigate the SOA formation initiated by α-terpineol ozonolysis for high (0.84 h-1 ), moderate (0.61 h-1 ), and low (0.36 h-1 ) air exchange rates (AER), which is the frequency with which indoor is replaced by outdoor air. α-Terpineol concentrations of 6.39 to 226 ppb were combined with high ozone (~25 ppm) to ensure rapid and complete ozonolysis. No reactants were replenished, so SOA peaked quickly and then decreased due to AER and surface losses, and peak SOA ranged from 2.03 to 281 μg/m3 at unit density. SOA mass formation was parameterized with the aerosol mass fraction (AMF), a.k.a. the SOA yield, and AMFs ranged from 0.056 to 0.24. The AMFs strongly and positively correlated with reacted α-terpineol, whereas they weakly and negatively correlated with higher AERs. One-product, two-product, and volatility basis set (VBS) models were fit to the AMF data. Predictive modeling demonstrated that α-terpineol ozonolysis could meaningfully form SOA in indoor air.
Collapse
Affiliation(s)
- Y Yang
- Department of Civil, Architectural and Environmental Engineering, Drexel University, Philadelphia, PA, USA
| | - M S Waring
- Department of Civil, Architectural and Environmental Engineering, Drexel University, Philadelphia, PA, USA
| |
Collapse
|
111
|
Khurshid SS, Siegel JA, Kinney KA. Particulate reactive oxygen species on total suspended particles - measurements in residences in Austin, Texas. INDOOR AIR 2016; 26:953-963. [PMID: 26588044 DOI: 10.1111/ina.12269] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/04/2015] [Accepted: 11/12/2015] [Indexed: 05/18/2023]
Abstract
The biologically relevant characteristics of particulate matter (PM) in homes are important to assessing human health. The concentration of particulate reactive oxygen species (ROS) was assessed in eight homes and was found to be lower inside (mean ± s.e. = 1.59 ± 0.33 nmol/m3 ) than outside (2.35 ± 0.57 nmol/m3 ). Indoor particulate ROS concentrations were substantial and a major fraction of indoor particulate ROS existed on PM2.5 (58 ± 10%), which is important from a health perspective as PM2.5 can carry ROS deep into the lungs. No obvious relationships were evident between selected building characteristics and indoor particulate ROS concentrations, but this observation would need to be verified by larger, controlled studies. Controlled experiments conducted at a test house suggest that indoor ozone and terpene concentrations substantially influence indoor particulate ROS concentrations when outdoor ozone concentrations are low, but have a weaker influence on indoor particulate ROS concentrations when outdoor ozone concentrations are high. The combination of substantial indoor concentrations and the time spent indoors suggest that further work is warranted to assess the key parameters that drive indoor particulate ROS concentrations.
Collapse
Affiliation(s)
- S S Khurshid
- Department of Civil, Architectural and Environmental Engineering, The University of Texas at Austin, Austin, TX, USA
| | - J A Siegel
- Department of Civil Engineering, The University of Toronto, Toronto, ON, Canada
- Dalla Lana School of Public Health, Division of Occupational & Environmental Health, The University of Toronto, Toronto, ON, Canada
| | - K A Kinney
- Department of Civil, Architectural and Environmental Engineering, The University of Texas at Austin, Austin, TX, USA
| |
Collapse
|
112
|
Hodas N, Loh M, Shin HM, Li D, Bennett D, McKone TE, Jolliet O, Weschler CJ, Jantunen M, Lioy P, Fantke P. Indoor inhalation intake fractions of fine particulate matter: review of influencing factors. INDOOR AIR 2016; 26:836-856. [PMID: 26562829 DOI: 10.1111/ina.12268] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2015] [Accepted: 11/02/2015] [Indexed: 05/21/2023]
Abstract
Exposure to fine particulate matter (PM2.5 ) is a major contributor to the global human disease burden. The indoor environment is of particular importance when considering the health effects associated with PM2.5 exposures because people spend the majority of their time indoors and PM2.5 exposures per unit mass emitted indoors are two to three orders of magnitude larger than exposures to outdoor emissions. Variability in indoor PM2.5 intake fraction (iFin,total ), which is defined as the integrated cumulative intake of PM2.5 per unit of emission, is driven by a combination of building-specific, human-specific, and pollutant-specific factors. Due to a limited availability of data characterizing these factors, however, indoor emissions and intake of PM2.5 are not commonly considered when evaluating the environmental performance of product life cycles. With the aim of addressing this barrier, a literature review was conducted and data characterizing factors influencing iFin,total were compiled. In addition to providing data for the calculation of iFin,total in various indoor environments and for a range of geographic regions, this paper discusses remaining limitations to the incorporation of PM2.5 -derived health impacts into life cycle assessments and makes recommendations regarding future research.
Collapse
Affiliation(s)
- N Hodas
- Division of Chemical Engineering, California Institute of Technology, Pasadena, CA, USA
- Department of Environmental Science and Management, Portland State University, Portland, OR, USA
| | - M Loh
- Institute of Occupational Medicine, Edinburgh, UK
| | - H-M Shin
- Department of Public Health Sciences, University of California, Davis, CA, USA
| | - D Li
- Department of Environmental Health Sciences, University of Michigan, Ann Arbor, MI, USA
| | - D Bennett
- Department of Public Health Sciences, University of California, Davis, CA, USA
| | - T E McKone
- School of Public Health, University of California, Berkeley, CA, USA
- Lawrence Berkeley National Laboratory, Berkeley, CA, USA
| | - O Jolliet
- Department of Environmental Health Sciences, University of Michigan, Ann Arbor, MI, USA
| | - C J Weschler
- Environmental and Occupational Health Sciences Institute, Rutgers University, Piscataway, NJ, USA
- International Centre for Indoor Environment and Energy, Technical University of Denmark, Kgs. Lyngby, Denmark
| | - M Jantunen
- Department of Environmental Health, National Institute for Health and Welfare, Helsinki, Finland
| | - P Lioy
- Environmental and Occupational Health Sciences Institute, Rutgers University, Piscataway, NJ, USA
| | - P Fantke
- Department of Management Engineering, Technical University of Denmark, Kgs. Lyngby, Denmark
| |
Collapse
|
113
|
Sanz J, González-Fernández I, Elvira S, Muntifering R, Alonso R, Bermejo-Bermejo V. Setting ozone critical levels for annual Mediterranean pasture species: Combined analysis of open-top chamber experiments. THE SCIENCE OF THE TOTAL ENVIRONMENT 2016; 571:670-679. [PMID: 27424112 DOI: 10.1016/j.scitotenv.2016.07.035] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/10/2016] [Revised: 07/04/2016] [Accepted: 07/05/2016] [Indexed: 06/06/2023]
Abstract
Annual Dehesa-type pastures comprise semi-natural vegetation communities dominated by annual species characteristic of the Mediterranean basin areas of Southern Europe. This study analyses all the datasets available on the effects of ozone (O3) on annual pasture species in order to review and propose new exposure- and flux-based O3 critical levels (CLes) following the methodology of the Convention on Long-Range Transboundary Air Pollution (CLRTAP). Based on the potential effect on pastures main ecosystem services, the availability of data and the statistical significance of the regressions, three variables have been selected for establishing CLes: total above-ground biomass, consumable food value (CFV), as a nutritional quality index, and reproductive capacity based on flower and seed production. New CLes proposed for a 10% loss (with 95% confidence intervals between brackets) of above-ground biomass and reproductive capacity were, respectively, AOT40=3.1 (2.6, 3.8) and 2.0 (1.5, 2.8) ppmh and POD1=12.2 (8.9, 15.5) and 7.2 (1.1, 13.3) mmolm(-2). The provisional AOT40- and POD1-based CLes for CFV were 2.3 (1.6, 4.0) ppmh and 4.6 (2.7, 6.5) mmolm(-2) respectively. By using only O3-sensitive species for the exposure and dose-response functions, the proposed CLes should be used for risk assessments. Their use for quantifying O3 damage may lead to an overestimation of the effects.
Collapse
Affiliation(s)
- J Sanz
- Ecotoxicology of Atmospheric Pollutants, CIEMAT, Avda. Complutense 40, 28040, Madrid, Spain.
| | - I González-Fernández
- Ecotoxicology of Atmospheric Pollutants, CIEMAT, Avda. Complutense 40, 28040, Madrid, Spain.
| | - S Elvira
- Ecotoxicology of Atmospheric Pollutants, CIEMAT, Avda. Complutense 40, 28040, Madrid, Spain.
| | - R Muntifering
- Department of Animal Sciences, Auburn University, Auburn, AL 36849, USA.
| | - R Alonso
- Ecotoxicology of Atmospheric Pollutants, CIEMAT, Avda. Complutense 40, 28040, Madrid, Spain.
| | - V Bermejo-Bermejo
- Ecotoxicology of Atmospheric Pollutants, CIEMAT, Avda. Complutense 40, 28040, Madrid, Spain.
| |
Collapse
|
114
|
Xiang J, Weschler CJ, Mo J, Day D, Zhang J, Zhang Y. Ozone, Electrostatic Precipitators, and Particle Number Concentrations: Correlations Observed in a Real Office during Working Hours. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2016; 50:10236-10244. [PMID: 27571436 DOI: 10.1021/acs.est.6b03069] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
This study investigates the impacts of outdoor and indoor ozone concentrations, ESP operation and occupancy on particle number concentrations within a modern office in Changsha, China. The office's one-pass air handling system contains a mini-bag filter (MERV 12) followed by an electrostatic precipitator (ESP) and high efficiency particulate air (HEPA) filter. Over a five-week period the system was operated either without the ESP (Stage 1, first-third week) or with the ESP (Stage 2, fourth and fifth week). Ozone and particle number concentrations were measured on working days. During both stages, indoor ozone and particle number concentrations tracked the outdoor ozone concentration. When operating, the ESP produced approximately 29 mg h(-1) of ozone, increasing supply air ozone by 15 ppb and steady-state indoor ozone by about 3 ppb. Occupancy tended to decrease indoor ozone and increase particle levels. During occupancy, indoor particle levels were low (∼2600 particle/cm(3)) when the supply air ozone level was less than 18 ppb. Above this threshold, the supply air ozone concentration and indoor particle number concentration were linearly related, and ESP operation increased the average indoor particle level by about 22 000 particles/cm(3). The implications for worker exposure to both ozone and particles are discussed.
Collapse
Affiliation(s)
- Jianbang Xiang
- Department of Building Science, Tsinghua University , Beijing 100084, China
- Beijing Key Laboratory of Indoor Air Quality Evaluation and Control, Beijing 100084, China
| | - Charles J Weschler
- Department of Building Science, Tsinghua University , Beijing 100084, China
- Beijing Key Laboratory of Indoor Air Quality Evaluation and Control, Beijing 100084, China
- Environmental and Occupational Health Sciences Institute, Rutgers University , Piscataway, New Jersey 08854, United States
| | - Jinhan Mo
- Department of Building Science, Tsinghua University , Beijing 100084, China
- Beijing Key Laboratory of Indoor Air Quality Evaluation and Control, Beijing 100084, China
| | - Drew Day
- Global Health Institute and the Nicholas School of Environment, Duke University , Durham, North Carolina 27708, United States
| | - Junfeng Zhang
- Global Health Institute and the Nicholas School of Environment, Duke University , Durham, North Carolina 27708, United States
- Duke Kunshan University , Kunshan, Jiangsu 215316, China
| | - Yinping Zhang
- Department of Building Science, Tsinghua University , Beijing 100084, China
- Beijing Key Laboratory of Indoor Air Quality Evaluation and Control, Beijing 100084, China
| |
Collapse
|
115
|
Yang S, Nie J, Wei F, Yang X. Removal of Ozone by Carbon Nanotubes/Quartz Fiber Film. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2016; 50:9592-9598. [PMID: 27501513 DOI: 10.1021/acs.est.6b02563] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Ozone is recognized as a harmful gaseous pollutant, which can lead to severe human health problems. In this study, carbon nanotubes (CNTs) were tested as a new approach for ozone removal. The CNTs/quartz fiber film was fabricated through growth of CNTs upon pure quartz fiber using chemical vapor deposition method. Ozone conversion efficiency of the CNTs/quartz fiber film was tested for 10 h and compared with that of quartz film, activated carbon (AC), and a potassium iodide (KI) solution under the same conditions. The pressure resistance of these materials under different airflow rates was also measured. The results showed that the CNTs/quartz fiber film had better ozone conversion efficiency but also higher pressure resistance than AC and the KI solution of the same weight. The ozone removal performance of the CNTs/quartz fiber film was comparable with AC at 20 times more weight. The CNTs played a dominant role in ozone removal by the CNTs/quartz fiber film. Its high ozone conversion efficiency, lightweight and free-standing properties make the CNTs/quartz fiber film applicable to ozone removal. Further investigation should be focused on reducing pressure resistance and studying the CNT mechanism for removing ozone.
Collapse
Affiliation(s)
- Shen Yang
- Department of Building Science, Tsinghua University , Beijing 100084, PR China
| | - Jingqi Nie
- Department of Chemical Engineering, Tsinghua University , Beijing 100084, PR China
| | - Fei Wei
- Department of Chemical Engineering, Tsinghua University , Beijing 100084, PR China
| | - Xudong Yang
- Department of Building Science, Tsinghua University , Beijing 100084, PR China
| |
Collapse
|
116
|
Tempo-Spatial Variations of Ambient Ozone-Mortality Associations in the USA: Results from the NMMAPS Data. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2016; 13:ijerph13090851. [PMID: 27571094 PMCID: PMC5036684 DOI: 10.3390/ijerph13090851] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/12/2016] [Revised: 08/08/2016] [Accepted: 08/11/2016] [Indexed: 12/04/2022]
Abstract
Although the health effects of ambient ozone have been widely assessed, their tempo-spatial variations remain unclear. We selected 20 communities (ten each from southern and northern USA) based on the US National Morbidity, Mortality, and Air Pollution Study (NMMAPS) dataset. A generalized linear model (GLM) was used to estimate the season-specific association between each 10 ppb (lag0-2 day average) increment in daily 8 h maximum ozone concentration and mortality in every community. The results showed that in the southern communities, a 10 ppb increment in ozone was linked to an increment of mortality of −0.07%, −0.17%, 0.40% and 0.27% in spring, summer, autumn and winter, respectively. For the northern communities, the excess risks (ERs) were 0.74%, 1.21%, 0.52% and −0.65% in the spring, summer, autumn and winter seasons, respectively. City-specific ozone-related mortality effects were positively related with latitude, but negatively related with seasonal average temperature in the spring, summer and autumn seasons. However, a reverse relationship was found in the winter. We concluded that there were different seasonal patterns of ozone effects on mortality between southern and northern US communities. Latitude and seasonal average temperature were identified as modifiers of the ambient ozone-related mortality risks.
Collapse
|
117
|
Zhao H, Stephens B. A method to measure the ozone penetration factor in residences under infiltration conditions: application in a multifamily apartment unit. INDOOR AIR 2016; 26:571-581. [PMID: 26114258 DOI: 10.1111/ina.12228] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/04/2015] [Accepted: 06/20/2015] [Indexed: 06/04/2023]
Abstract
Recent experiments have demonstrated that outdoor ozone reacts with materials inside residential building enclosures, potentially reducing indoor exposures to ozone or altering ozone reaction byproducts. However, test methods to measure ozone penetration factors in residences (P) remain limited. We developed a method to measure ozone penetration factors in residences under infiltration conditions and applied it in an unoccupied apartment unit. Twenty-four repeated measurements were made, and results were explored to (i) evaluate the accuracy and repeatability of the new procedure using multiple solution methods, (ii) compare results from 'interference-free' and conventional UV absorbance ozone monitors, and (iii) compare results against those from a previously published test method requiring artificial depressurization. The mean (±s.d.) estimate of P was 0.54 ± 0.10 across a wide range of conditions using the new method with an interference-free monitor; the conventional monitor was unable to yield meaningful results due to relatively high limits of detection. Estimates of P were not clearly influenced by any indoor or outdoor environmental conditions or changes in indoor decay rate constants. This work represents the first known measurements of ozone penetration factors in a residential building operating under natural infiltration conditions and provides a new method for widespread application in buildings.
Collapse
Affiliation(s)
- H Zhao
- Department of Civil, Architectural and Environmental Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - B Stephens
- Department of Civil, Architectural and Environmental Engineering, Illinois Institute of Technology, Chicago, IL, USA
| |
Collapse
|
118
|
Al horr Y, Arif M, Katafygiotou M, Mazroei A, Kaushik A, Elsarrag E. Impact of indoor environmental quality on occupant well-being and comfort: A review of the literature. ACTA ACUST UNITED AC 2016. [DOI: 10.1016/j.ijsbe.2016.03.006] [Citation(s) in RCA: 311] [Impact Index Per Article: 38.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
119
|
Aldred JR, Darling E, Morrison G, Siegel J, Corsi RL. Benefit-cost analysis of commercially available activated carbon filters for indoor ozone removal in single-family homes. INDOOR AIR 2016; 26:501-512. [PMID: 25952610 DOI: 10.1111/ina.12220] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/20/2015] [Accepted: 05/02/2015] [Indexed: 06/04/2023]
Abstract
This study involved the development of a model for evaluating the potential costs and benefits of ozone control by activated carbon filtration in single-family homes. The modeling effort included the prediction of indoor ozone with and without activated carbon filtration in the HVAC system. As one application, the model was used to predict benefit-to-cost ratios for single-family homes in 12 American cities in five different climate zones. Health benefits were evaluated using disability-adjusted life-years and included city-specific age demographics for each simulation. Costs of commercially available activated carbon filters included capital cost differences when compared to conventional HVAC filters of similar particle removal efficiency, energy penalties due to additional pressure drop, and regional utility rates. The average indoor ozone removal effectiveness ranged from 4 to 20% across the 12 target cities and was largely limited by HVAC system operation time. For the parameters selected in this study, the mean predicted benefit-to-cost ratios for 1-inch filters were >1.0 in 10 of the 12 cities. The benefits of residential activated carbon filters were greatest in cities with high seasonal ozone and HVAC usage, suggesting the importance of targeting such conditions for activated carbon filter applications.
Collapse
Affiliation(s)
- J R Aldred
- Department of Civil, Architectural, and Environmental Engineering, University of Texas, Austin, TX, USA
| | - E Darling
- Department of Civil, Architectural, and Environmental Engineering, University of Texas, Austin, TX, USA
| | - G Morrison
- Department of Civil, Architectural, and Environmental Engineering, Missouri University of Science and Technology, Rolla, MO, USA
| | - J Siegel
- Department of Civil Engineering, University of Toronto, Toronto, ON, Canada
- Dalla Lana School of Public Health, University of Toronto, Toronto, ON, Canada
| | - R L Corsi
- Department of Civil, Architectural, and Environmental Engineering, University of Texas, Austin, TX, USA
| |
Collapse
|
120
|
Melikov AK. Advanced air distribution: improving health and comfort while reducing energy use. INDOOR AIR 2016; 26:112-24. [PMID: 25833265 DOI: 10.1111/ina.12206] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/26/2014] [Accepted: 03/27/2015] [Indexed: 05/20/2023]
Abstract
Indoor environment affects the health, comfort, and performance of building occupants. The energy used for heating, cooling, ventilating, and air conditioning of buildings is substantial. Ventilation based on total volume air distribution in spaces is not always an efficient way to provide high-quality indoor environments at the same time as low-energy consumption. Advanced air distribution, designed to supply clean air where, when, and as much as needed, makes it possible to efficiently achieve thermal comfort, control exposure to contaminants, provide high-quality air for breathing and minimizing the risk of airborne cross-infection while reducing energy use. This study justifies the need for improving the present air distribution design in occupied spaces, and in general the need for a paradigm shift from the design of collective environments to the design of individually controlled environments. The focus is on advanced air distribution in spaces, its guiding principles and its advantages and disadvantages. Examples of advanced air distribution solutions in spaces for different use, such as offices, hospital rooms, vehicle compartments, are presented. The potential of advanced air distribution, and individually controlled macro-environment in general, for achieving shared values, that is, improved health, comfort, and performance, energy saving, reduction of healthcare costs and improved well-being is demonstrated. Performance criteria are defined and further research in the field is outlined.
Collapse
Affiliation(s)
- A K Melikov
- Department of Civil Engineering, International Centre for Indoor Environment and Energy, Technical University of Denmark, Lyngby, Denmark
| |
Collapse
|
121
|
|
122
|
ITO K. Toward the development of an in silico human model for indoor environmental design. PROCEEDINGS OF THE JAPAN ACADEMY. SERIES B, PHYSICAL AND BIOLOGICAL SCIENCES 2016; 92:185-203. [PMID: 27477455 PMCID: PMC5114289 DOI: 10.2183/pjab.92.185] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
In modern society where people spend more than 90% of their time in indoor spaces, the indoor air quality (IAQ) created by buildings has the potential of greatly influencing quality of life. Because the time spent by workers/residents in indoor spaces has increased over time, the importance of IAQ issues in terms of public health is also increasing. Additionally, the quality of the indoor thermal environment also has great impact on human comfort and performance; hence, the development of a comprehensive prediction method integrating indoor air quality/thermal environment assessment and human physiological responses, is crucial for creating a healthy, comfortable, and productive indoor environment. Accordingly, the overarching objective of this study was to develop a comprehensive and universal computer simulated person (i.e., in silico human model), integrating computational fluid dynamics (CFD), to be used in indoor environmental design and quality assessment. This paper presents and discusses the development of this computer-simulated person and its application to indoor environmental design.
Collapse
Affiliation(s)
- Kazuhide ITO
- Faculty of Engineering Sciences, Kyushu University, Kasuga, Fukuoka, Japan
- Correspondence should be addressed: K. Ito, Faculty of Engineering Science, Kyushu University, 6-1 Kasuga-koen, Kasuga, Fukuoka 816-8580, Japan (e-mail: )
| |
Collapse
|
123
|
Liu B, Hu X, Chai J, Zhu J, Yang B, Li Y. Application of nanodiamonds in Cu(ii)-based rhodamine B probes for NO detection and cell imaging. J Mater Chem B 2016; 4:3358-3364. [DOI: 10.1039/c6tb00524a] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A nanodiamond-conjugated rhodamine fluorescent sensor for Cu(ii) which could then be developed as an excellent NO selective fluorescent particle.
Collapse
Affiliation(s)
- Bin Liu
- Key Laboratory of Chemical Biology
- Molecular Engineering of Ministry of Education
- Institute of Molecular Science
- Shanxi University
- Taiyuan 030006
| | - Xiangquan Hu
- Key Laboratory of Chemical Biology
- Molecular Engineering of Ministry of Education
- Institute of Molecular Science
- Shanxi University
- Taiyuan 030006
| | - Jie Chai
- Key Laboratory of Chemical Biology
- Molecular Engineering of Ministry of Education
- Institute of Molecular Science
- Shanxi University
- Taiyuan 030006
| | - Junyao Zhu
- Department of Chemistry
- College of Chemistry and Chemical Engineering
- Shanxi University
- Taiyuan
- P. R. China
| | - Binsheng Yang
- Key Laboratory of Chemical Biology
- Molecular Engineering of Ministry of Education
- Institute of Molecular Science
- Shanxi University
- Taiyuan 030006
| | - Yingqi Li
- Key Laboratory of Chemical Biology
- Molecular Engineering of Ministry of Education
- Institute of Molecular Science
- Shanxi University
- Taiyuan 030006
| |
Collapse
|
124
|
Dimitroulopoulou C, Trantallidi M, Carrer P, Efthimiou GC, Bartzis JG. EPHECT II: Exposure assessment to household consumer products. THE SCIENCE OF THE TOTAL ENVIRONMENT 2015; 536:890-902. [PMID: 26173853 DOI: 10.1016/j.scitotenv.2015.05.138] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2015] [Revised: 05/29/2015] [Accepted: 05/29/2015] [Indexed: 05/07/2023]
Abstract
Within the framework of the EPHECT project (Emissions, exposure patterns and health effects of consumer products in the EU), irritative and respiratory health effects were assessed in relation to acute and long-term exposure to key and emerging indoor air pollutants emitted during household use of selected consumer products. In this context, inhalation exposure assessment was carried out for six selected 'target' compounds (acrolein, formaldehyde, benzene, naphthalene, d-limonene and α-pinene). This paper presents the methodology and the outcomes from the micro-environmental modelling of the 'target' pollutants following single or multiple use of selected consumer products and the subsequent exposure assessment. The results indicate that emissions from consumer products of benzene and α-pinene were not considered to contribute significantly to the EU indoor background levels, in contrast to some cases of formaldehyde and d-limonene emissions in Eastern Europe (mainly from cleaning products). The group of housekeepers in East Europe appears to experience the highest exposures to acrolein, formaldehyde and benzene, followed by the group of the retired people in North, who experiences the highest exposures to naphthalene and α-pinene. High exposure may be attributed to the scenarios developed within this project, which follow a 'most-representative worst-case scenario' strategy for exposure and health risk assessment. Despite the above limitations, this is the first comprehensive study that provides exposure estimates for 8 population groups across Europe exposed to 6 priority pollutants, as a result of the use of 15 consumer product classes in households, while accounting for regional differences in uses, use scenarios and ventilation conditions of each region.
Collapse
Affiliation(s)
- C Dimitroulopoulou
- Dept. of Mechanical Engineering, University of West Macedonia, 50100 Kozani, Greece; Centre for Radiation, Chemical and Environmental Hazards, Public Health England, Harwell Science and Innovation Campus, OX11 0RQ, UK.
| | - M Trantallidi
- Dept. of Biomedical and Clinical Sciences - Hospital L. Sacco, University of Milan, 20157 Milan, Italy
| | - P Carrer
- Dept. of Biomedical and Clinical Sciences - Hospital L. Sacco, University of Milan, 20157 Milan, Italy
| | - G C Efthimiou
- Dept. of Mechanical Engineering, University of West Macedonia, 50100 Kozani, Greece
| | - J G Bartzis
- Dept. of Mechanical Engineering, University of West Macedonia, 50100 Kozani, Greece
| |
Collapse
|
125
|
Vardoulakis S, Dimitroulopoulou C, Thornes J, Lai KM, Taylor J, Myers I, Heaviside C, Mavrogianni A, Shrubsole C, Chalabi Z, Davies M, Wilkinson P. Impact of climate change on the domestic indoor environment and associated health risks in the UK. ENVIRONMENT INTERNATIONAL 2015; 85:299-313. [PMID: 26453820 DOI: 10.1016/j.envint.2015.09.010] [Citation(s) in RCA: 85] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/20/2015] [Revised: 07/30/2015] [Accepted: 09/07/2015] [Indexed: 05/25/2023]
Abstract
There is growing evidence that projected climate change has the potential to significantly affect public health. In the UK, much of this impact is likely to arise by amplifying existing risks related to heat exposure, flooding, and chemical and biological contamination in buildings. Identifying the health effects of climate change on the indoor environment, and risks and opportunities related to climate change adaptation and mitigation, can help protect public health. We explored a range of health risks in the domestic indoor environment related to climate change, as well as the potential health benefits and unintended harmful effects of climate change mitigation and adaptation policies in the UK housing sector. We reviewed relevant scientific literature, focusing on housing-related health effects in the UK likely to arise through either direct or indirect mechanisms of climate change or mitigation and adaptation measures in the built environment. We considered the following categories of effect: (i) indoor temperatures, (ii) indoor air quality, (iii) indoor allergens and infections, and (iv) flood damage and water contamination. Climate change may exacerbate health risks and inequalities across these categories and in a variety of ways, if adequate adaptation measures are not taken. Certain changes to the indoor environment can affect indoor air quality or promote the growth and propagation of pathogenic organisms. Measures aimed at reducing greenhouse gas emissions have the potential for ancillary public health benefits including reductions in health burdens related heat and cold, indoor exposure to air pollution derived from outdoor sources, and mould growth. However, increasing airtightness of dwellings in pursuit of energy efficiency could also have negative effects by increasing concentrations of pollutants (such as PM2.5, CO and radon) derived from indoor or ground sources, and biological contamination. These effects can largely be ameliorated by mechanical ventilation with heat recovery (MVHR) and air filtration, where such solution is feasible and when the system is properly installed, operated and maintained. Groups at high risk of these adverse health effects include the elderly (especially those living on their own), individuals with pre-existing illnesses, people living in overcrowded accommodation, and the socioeconomically deprived. A better understanding of how current and emerging building infrastructure design, construction, and materials may affect health in the context of climate change and mitigation and adaptation measures is needed in the UK and other high income countries. Long-term, energy efficient building design interventions, ensuring adequate ventilation, need to be promoted.
Collapse
Affiliation(s)
- Sotiris Vardoulakis
- Environmental Change Department, Centre for Radiation, Chemical and Environmental Hazards, Public Health England, Chilton, Oxon OX11 0RQ, UK; Department of Social and Environmental Health Research, London School of Hygiene and Tropical Medicine, 15-17 Tavistock Place, London WC1H 9SH, UK; Division of Environmental Health and Risk Management, School of Geography, Earth and Environmental Sciences, University of Birmingham, Edgbaston, Birmingham B15 2TT, UK.
| | - Chrysanthi Dimitroulopoulou
- Environmental Change Department, Centre for Radiation, Chemical and Environmental Hazards, Public Health England, Chilton, Oxon OX11 0RQ, UK.
| | - John Thornes
- Environmental Change Department, Centre for Radiation, Chemical and Environmental Hazards, Public Health England, Chilton, Oxon OX11 0RQ, UK; Division of Environmental Health and Risk Management, School of Geography, Earth and Environmental Sciences, University of Birmingham, Edgbaston, Birmingham B15 2TT, UK.
| | - Ka-Man Lai
- Department of Biology, Hong Kong Baptist University, Kowloon Tong, Hong Kong, China.
| | - Jonathon Taylor
- UCL Institute for Environmental Design and Engineering, The Bartlett School of Environment Energy and Resources, University College London, 14 Upper Woburn Place, London WCIH ONN, UK.
| | - Isabella Myers
- Public Health England Toxicology Unit, Department of Medicine, Imperial College London, London W12 0NN, UK.
| | - Clare Heaviside
- Environmental Change Department, Centre for Radiation, Chemical and Environmental Hazards, Public Health England, Chilton, Oxon OX11 0RQ, UK; Department of Social and Environmental Health Research, London School of Hygiene and Tropical Medicine, 15-17 Tavistock Place, London WC1H 9SH, UK; Division of Environmental Health and Risk Management, School of Geography, Earth and Environmental Sciences, University of Birmingham, Edgbaston, Birmingham B15 2TT, UK.
| | - Anna Mavrogianni
- UCL Institute for Environmental Design and Engineering, The Bartlett School of Environment Energy and Resources, University College London, 14 Upper Woburn Place, London WCIH ONN, UK.
| | - Clive Shrubsole
- UCL Institute for Environmental Design and Engineering, The Bartlett School of Environment Energy and Resources, University College London, 14 Upper Woburn Place, London WCIH ONN, UK.
| | - Zaid Chalabi
- Department of Social and Environmental Health Research, London School of Hygiene and Tropical Medicine, 15-17 Tavistock Place, London WC1H 9SH, UK.
| | - Michael Davies
- UCL Institute for Environmental Design and Engineering, The Bartlett School of Environment Energy and Resources, University College London, 14 Upper Woburn Place, London WCIH ONN, UK.
| | - Paul Wilkinson
- Department of Social and Environmental Health Research, London School of Hygiene and Tropical Medicine, 15-17 Tavistock Place, London WC1H 9SH, UK.
| |
Collapse
|
126
|
Fadeyi MO, Tham KW, Wu WY. Impact of asthma, exposure period, and filters on human responses during exposures to ozone and its initiated chemistry products. INDOOR AIR 2015; 25:512-522. [PMID: 25250543 DOI: 10.1111/ina.12161] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2014] [Accepted: 09/18/2014] [Indexed: 06/03/2023]
Abstract
The impact of asthma, exposure period, and filter condition downstream of the mixing box of air-conditioning system on building occupants' perceptual response, work performance, and salivary α-amylase secretion during exposures to ozone and its initiated chemistry products is studied. The experiments were conducted in a field environmental chamber (FEC) (240 m(3)) simulating an office environment. Experiments were conducted during periods when the air-handling system operated with new or used pleated panel filters at constant recirculation (7/h) and ventilation (1/h) rates. Average ozone and secondary organic aerosols (ozone-initiated chemistry products) measured during non-asthmatic and asthmatic subjects' 3-h exposures in the FEC were in the ranges approximately 20-37 ppb and approximately 1.6-3 μg/m(3), respectively. Asthmatic subjects' perceived odor intensity and sensory (eye, nose, and throat) irritation ratings were generally lower than those of non-asthmatic subjects, possibly explaining why asthmatic subjects accept perceived air quality more than non-asthmatic subjects. However, asthmatic subjects' perceived physiological-like symptom ratings (flu, chest tightness, and headache) and concentrations of secreted salivary α-amylase were generally higher than those of non-asthmatic subjects. Asthmatic subjects had significantly lower accuracy than non-asthmatic subjects in a task that required higher concentration although they had higher work speed. Filter condition did not make any significant difference for subjects' responses.
Collapse
Affiliation(s)
- M O Fadeyi
- Berkeley Education Alliance for Research in Singapore, Singapore
- School of Civil and Environmental Engineering, Nanyang Technological University, Singapore
| | - K W Tham
- Department of Building, School of Design and Environment, National University of Singapore, Singapore
| | - W Y Wu
- Department of Building, School of Design and Environment, National University of Singapore, Singapore
| |
Collapse
|
127
|
Kim ER, Park RJ, Lee DG, Kim JJ. A Study on the Characteristics of Flow and Reactive Pollutants' Dispersion in Step-up Street Canyons Using a CFD Model. ATMOSPHERE 2015. [DOI: 10.14191/atmos.2015.25.3.473] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
128
|
Bekö G, Allen JG, Weschler CJ, Vallarino J, Spengler JD. Impact of cabin ozone concentrations on passenger reported symptoms in commercial aircraft. PLoS One 2015; 10:e0128454. [PMID: 26011001 PMCID: PMC4444275 DOI: 10.1371/journal.pone.0128454] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2014] [Accepted: 04/27/2015] [Indexed: 11/20/2022] Open
Abstract
Due to elevated ozone concentrations at high altitudes, the adverse effect of ozone on air quality, human perception and health may be more pronounced in aircraft cabins. The association between ozone and passenger-reported symptoms has not been investigated under real conditions since smoking was banned on aircraft and ozone converters became more common. Indoor environmental parameters were measured at cruising altitude on 83 US domestic and international flights. Passengers completed a questionnaire about symptoms and satisfaction with the indoor air quality. Average ozone concentrations were relatively low (median: 9.5 ppb). On thirteen flights (16%) ozone levels exceeded 60 ppb, while the highest peak level reached 256 ppb for a single flight. The most commonly reported symptoms were dry mouth or lips (26%), dry eyes (22.1%) and nasal stuffiness (18.9%). 46% of passengers reported at least one symptom related to the eyes or mouth. A third of the passengers reported at least one upper respiratory symptom. Using multivariate logistic (individual symptoms) and linear (aggregated continuous symptom variables) regression, ozone was consistently associated with symptoms related to the eyes and certain upper respiratory endpoints. A concentration-response relationship was observed for nasal stuffiness and eye and upper respiratory symptom indicators. Average ozone levels, as opposed to peak concentrations, exhibited slightly weaker associations. Medium and long duration flights were significantly associated with more symptoms compared to short flights. The relationship between ultrafine particles and ozone on flights without meal service was indicative of ozone-initiated chemistry.
Collapse
Affiliation(s)
- Gabriel Bekö
- International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, Lyngby, Denmark
| | - Joseph G. Allen
- Department of Environmental Health, Harvard School of Public Health, Boston, Massachusetts, United States of America
| | - Charles J. Weschler
- International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, Lyngby, Denmark
- Environmental and Occupational Health Sciences Institute, Rutgers University, Piscataway, New Jersey, United States of America
| | - Jose Vallarino
- Department of Environmental Health, Harvard School of Public Health, Boston, Massachusetts, United States of America
| | - John D. Spengler
- Department of Environmental Health, Harvard School of Public Health, Boston, Massachusetts, United States of America
| |
Collapse
|
129
|
Pöschl U, Shiraiwa M. Multiphase chemistry at the atmosphere-biosphere interface influencing climate and public health in the anthropocene. Chem Rev 2015; 115:4440-75. [PMID: 25856774 DOI: 10.1021/cr500487s] [Citation(s) in RCA: 232] [Impact Index Per Article: 25.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
- Ulrich Pöschl
- Multiphase Chemistry Department, Max Planck Institute for Chemistry, 55128 Mainz, Germany
| | - Manabu Shiraiwa
- Multiphase Chemistry Department, Max Planck Institute for Chemistry, 55128 Mainz, Germany
| |
Collapse
|
130
|
Gall ET, Siegel JA, Corsi RL. Modeling ozone removal to indoor materials, including the effects of porosity, pore diameter, and thickness. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2015; 49:4398-406. [PMID: 25748309 DOI: 10.1021/acs.est.5b00023] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
We develop an ozone transport and reaction model to determine reaction probabilities and assess the importance of physical properties such as porosity, pore diameter, and material thickness on reactive uptake of ozone to five materials. The one-dimensional model accounts for molecular diffusion from bulk air to the air-material interface, reaction at the interface, and diffusive transport and reaction through material pore volumes. Material-ozone reaction probabilities that account for internal transport and internal pore area, γ(ipa), are determined by a minimization of residuals between predicted and experimentally derived ozone concentrations. Values of γ(ipa) are generally less than effective reaction probabilities (γ(eff)) determined previously, likely because of the inclusion of diffusion into substrates and reaction with internal surface area (rather than the use of the horizontally projected external material areas). Estimates of γ(ipa) average 1 × 10(-7), 2 × 10(-7), 4 × 10(-5), 2 × 10(-5), and 4 × 10(-7) for two types of cellulose paper, pervious pavement, Portland cement concrete, and an activated carbon cloth, respectively. The transport and reaction model developed here accounts for observed differences in ozone removal to varying thicknesses of the cellulose paper, and estimates a near constant γ(ipa) as material thickness increases from 0.02 to 0.16 cm.
Collapse
Affiliation(s)
- Elliott T Gall
- †Nanyang Technological University and Berkeley Education Alliance for Research in Singapore, 1 Create Way #11-01 Create Tower, Singapore, 138602
| | - Jeffrey A Siegel
- ‡Department of Civil Engineering and Dalla Lana School of Public Health, University of Toronto, 35 St. George St., Toronto, Ontario M5S 1A4, Canada
| | - Richard L Corsi
- §Department of Civil, Architectural and Environmental Engineering, Cockrell School of Engineering, The University of Texas at Austin, 1 University Station C1786, Austin, Texas 78712, United States
| |
Collapse
|
131
|
Montesinos VN, Sleiman M, Cohn S, Litter MI, Destaillats H. Detection and quantification of reactive oxygen species (ROS) in indoor air. Talanta 2015; 138:20-27. [PMID: 25863366 DOI: 10.1016/j.talanta.2015.02.015] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2015] [Revised: 02/06/2015] [Accepted: 02/09/2015] [Indexed: 11/19/2022]
Abstract
Reactive oxygen species (ROS), such as free radicals and peroxides, are environmental trace pollutants potentially associated with asthma and airways inflammation. These compounds are often not detected in indoor air due to sampling and analytical limitations. This study developed and validated an experimental method to sample, identify and quantify ROS in indoor air using fluorescent probes. Tests were carried out simultaneously using three different probes: 2',7'-dichlorofluorescin (DCFH) to detect a broad range of ROS, Amplex ultra Red® (AuR) to detect peroxides, and terephthalic acid (TPA) to detect hydroxyl radicals (HO(•)). For each test, air samples were collected using two impingers in series kept in an ice bath, containing each 10 mL of 50 mM phosphate buffer at pH 7.2. In tests with TPA, that probe was also added to the buffer prior to sampling; in the other two tests, probes and additional reactants were added immediately after sampling. The concentration of fluorescent byproducts was determined fluorometrically. Calibration curves were developed by reacting DCFH and AuR with known amounts of H2O2, and using known amounts of 2-hydroxyterephthalic acid (HTPA) for TPA. Low detection limits (9-13 nM) and quantification limits (18-22 nM) were determined for all three probes, which presented a linear response in the range 10-500 nM for AuR and TPA, and 100-2000 nM for DCFH. High collection efficiency (CE) and recovery efficiency (RE) were observed for DCFH (CE=RE=100%) and AuR (CE=100%; RE=73%) by sampling from a laboratory-developed gas phase H2O2 generator. Interference of co-occurring ozone was evaluated and quantified for the three probes by sampling from the outlet of an ozone generator. The method was demonstrated by sampling air emitted by two portable air cleaners: a strong ozone generator (AC1) and a plasma generator (AC2). High ozone levels emitted by AC1 did not allow for simultaneous determination of ROS levels due to high background levels associated with ozone decomposition in the buffer. However, emitted ROS were quantified at the outlet of AC2 using two of the three probes. With AuR, the concentration of peroxides in air emitted by the air cleaner was 300 ppt of H2O2 equivalents. With TPA, the HO(•) concentration was 47 ppt. This method is best suited to quantify ROS in the presence of low ozone levels.
Collapse
Affiliation(s)
- V Nahuel Montesinos
- Comisión Nacional de Energía Atómica, Avenida Gral. Paz 1499, 1650 San Martín, Provincia de Buenos Aires, Argentina; Consejo Nacional de Investigaciones Científicas y Técnicas, Avenida Rivadavia 1917, 1033 Ciudad Autónoma de Buenos Aires, Argentina; Universidad de Buenos Aires, FCEN, INQUIMAE, DQIAQF, Ciudad Universitaria Pabellón II, 1428 Ciudad Autónoma de Buenos Aires, Argentina
| | - Mohamad Sleiman
- Lawrence Berkeley National Laboratory, Indoor Environment Group, 1 Cyclotron Road MS 70-108B, Berkeley, CA, USA; Clermont Université, ENSCCF, Institut de Chimie de Clermont-Ferrand, BP 10448, F-63000 Clermont-Ferrand, France; CNRS, UMR 6296, ICCF, BP 80026, F-63177 Aubière, France
| | - Sebastian Cohn
- Lawrence Berkeley National Laboratory, Indoor Environment Group, 1 Cyclotron Road MS 70-108B, Berkeley, CA, USA
| | - Marta I Litter
- Comisión Nacional de Energía Atómica, Avenida Gral. Paz 1499, 1650 San Martín, Provincia de Buenos Aires, Argentina; Consejo Nacional de Investigaciones Científicas y Técnicas, Avenida Rivadavia 1917, 1033 Ciudad Autónoma de Buenos Aires, Argentina; Universidad de General San Martín, Instituto de Investigación e Ingeniería Ambiental, Peatonal Belgrano 3563, 1650 San Martín, Pcia. Buenos Aires, Argentina
| | - Hugo Destaillats
- Lawrence Berkeley National Laboratory, Indoor Environment Group, 1 Cyclotron Road MS 70-108B, Berkeley, CA, USA.
| |
Collapse
|
132
|
Laumbach R, Meng Q, Kipen H. What can individuals do to reduce personal health risks from air pollution? J Thorac Dis 2015; 7:96-107. [PMID: 25694820 PMCID: PMC4311076 DOI: 10.3978/j.issn.2072-1439.2014.12.21] [Citation(s) in RCA: 52] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2014] [Accepted: 11/20/2014] [Indexed: 01/08/2023]
Abstract
In many areas of the world, concentrations of ambient air pollutants exceed levels associated with increased risk of acute and chronic health problems. While effective policies to reduce emissions at their sources are clearly preferable, some evidence supports the effectiveness of individual actions to reduce exposure and health risks. Personal exposure to ambient air pollution can be reduced on high air pollution days by staying indoors, reducing outdoor air infiltration to indoors, cleaning indoor air with air filters, and limiting physical exertion, especially outdoors and near air pollution sources. Limited evidence suggests that the use of respirators may be effective in some circumstances. Awareness of air pollution levels is facilitated by a growing number of public air quality alert systems. Avoiding exposure to air pollutants is especially important for susceptible individuals with chronic cardiovascular or pulmonary disease, children, and the elderly. Research on mechanisms underlying the adverse health effects of air pollution have suggested potential pharmaceutical or chemopreventive interventions, such as antioxidant or antithrombotic agents, but in the absence of data on health outcomes, no sound recommendations can be made for primary prevention. Health care providers and their patients should carefully consider individual circumstances related to outdoor and indoor air pollutant exposure levels and susceptibility to those air pollutants when deciding on a course of action to reduce personal exposure and health risks from ambient air pollutants. Careful consideration is especially warranted when interventions may have unintended negative consequences, such as when efforts to avoid exposure to air pollutants lead to reduced physical activity or when there is evidence that dietary supplements, such as antioxidants, have potential adverse health effects. These potential complications of partially effective personal interventions to reduce exposure or risk highlight the primary importance of reducing emissions of air pollutants at their sources.
Collapse
Affiliation(s)
- Robert Laumbach
- Environmental and Occupational Health Sciences Institute, Rutgers University, 170 Frelinghuysen Rd., Piscataway, NJ 08854, USA
| | - Qingyu Meng
- Environmental and Occupational Health Sciences Institute, Rutgers University, 170 Frelinghuysen Rd., Piscataway, NJ 08854, USA
| | - Howard Kipen
- Environmental and Occupational Health Sciences Institute, Rutgers University, 170 Frelinghuysen Rd., Piscataway, NJ 08854, USA
| |
Collapse
|
133
|
Lian Z, Ma J, He H. Decomposition of high-level ozone under high humidity over Mn–Fe catalyst: The influence of iron precursors. CATAL COMMUN 2015. [DOI: 10.1016/j.catcom.2014.10.005] [Citation(s) in RCA: 84] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022] Open
|
134
|
Glas B, Stenberg B, Stenlund H, Sunesson AL. Exposure to formaldehyde, nitrogen dioxide, ozone, and terpenes among office workers and associations with reported symptoms. Int Arch Occup Environ Health 2014; 88:613-22. [DOI: 10.1007/s00420-014-0985-y] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2014] [Accepted: 09/16/2014] [Indexed: 11/24/2022]
|
135
|
Waring MS. Secondary organic aerosol in residences: predicting its fraction of fine particle mass and determinants of formation strength. INDOOR AIR 2014; 24:376-89. [PMID: 24387324 DOI: 10.1111/ina.12092] [Citation(s) in RCA: 54] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/09/2013] [Accepted: 12/24/2013] [Indexed: 05/04/2023]
Abstract
UNLABELLED Indoor secondary organic aerosol (SOA) formation may contribute to particle concentrations within residences, but little systematic work has investigated its magnitude or the determinants of its formation. This work uses a time-averaged modeling approach to predict the indoor SOA mass formed in residences due to the oxidation of 66 reactive organic compounds by ozone or the hydroxyl radical, parameterizing SOA formation with the aerosol mass fraction. Other organic and inorganic aerosols owing to outdoor and indoor sources were also predicted. Model inputs were represented as distributions within a Monte Carlo analysis, so that result distributions and sensitivity of results to inputs could be quantified, using a dataset developed from the study of Relationships between Indoor, Outdoor and Personal Air and other sources. SOA comprised a large amount of indoor organic and total fine particles for a subset of the results (e.g., >47% of indoor organic and >30% of fine aerosol for 10% of the modeled cases), but was often a small fraction. The sensitivity analysis revealed that SOA formation is driven by high terpene emission rates (particularly by d-limonene) and outdoor ozone, along with low air exchange and ozone and particle deposition rates. PRACTICAL IMPLICATIONS This study predicts that indoor SOA formation can be a substantial fraction of indoor aerosols in residences, for certain combinations of building and reactant parameters. The model herein can predict SOA for risk analyses or be used to design experiments to study indoor SOA formation. The terpene, d-limonene, contributes by far the most to formation, and eliminating this particular compound indoors would be impactful on indoor aerosol concentrations.
Collapse
Affiliation(s)
- M S Waring
- Department of Civil, Architectural and Environmental Engineering, Drexel University, Philadelphia, PA, USA
| |
Collapse
|
136
|
Khurshid SS, Siegel JA, Kinney KA. Indoor particulate reactive oxygen species concentrations. ENVIRONMENTAL RESEARCH 2014; 132:46-53. [PMID: 24742727 DOI: 10.1016/j.envres.2014.03.026] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/20/2013] [Revised: 02/21/2014] [Accepted: 03/12/2014] [Indexed: 05/18/2023]
Abstract
Despite the fact that precursors to reactive oxygen species (ROS) are prevalent indoors, the concentration of ROS inside buildings is unknown. ROS on PM2.5 was measured inside and outside twelve residential buildings and eleven institutional and retail buildings. The mean (± s.d.) concentration of ROS on PM2.5 inside homes (1.37 ± 1.2 nmoles/m(3)) was not significantly different from the outdoor concentration (1.41 ± 1.0 nmoles/m(3)). Similarly, the indoor and outdoor concentrations of ROS on PM2.5 at institutional buildings (1.16 ± 0.38 nmoles/m(3) indoors and 1.68 ± 1.3 nmoles/m(3) outdoors) and retail stores (1.09 ± 0.93 nmoles/m(3) indoors and 1.12 ± 1.1 nmoles/m(3) outdoors) were not significantly different and were comparable to those in residential buildings. The indoor concentration of particulate ROS cannot be predicted based on the measurement of other common indoor pollutants, indicating that it is important to separately assess the concentration of particulate ROS in air quality studies. Daytime indoor occupational and residential exposure to particulate ROS dominates daytime outdoor exposure to particulate ROS. These findings highlight the need for further study of ROS in indoor microenvironments.
Collapse
Affiliation(s)
- Shahana S Khurshid
- Department of Civil, Architectural and Environmental Engineering, The University of Texas at Austin, Austin, TX, USA.
| | - Jeffrey A Siegel
- Department of Civil Engineering, The University of Toronto, Toronto, ON, Canada
| | - Kerry A Kinney
- Department of Civil, Architectural and Environmental Engineering, The University of Texas at Austin, Austin, TX, USA
| |
Collapse
|
137
|
Gall ET, Corsi RL, Siegel JA. Impact of physical properties on ozone removal by several porous materials. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2014; 48:3682-3690. [PMID: 24568620 DOI: 10.1021/es4051956] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Models of reactive uptake of ozone in indoor environments generally describe materials through aerial (horizontal) projections of surface area, a potentially limiting assumption for porous materials. We investigated the effect of changing porosity/pore size, material thickness, and chamber fluid mechanic conditions on the reactive uptake of ozone to five materials: two cellulose filter papers, two cementitious materials, and an activated carbon cloth. Results include (1) material porosity and pore size distributions, (2) effective diffusion coefficients for ozone in materials, and (3) material-ozone deposition velocities and reaction probabilities. At small length scales (0.02-0.16 cm) increasing thickness caused increases in estimated reaction probabilities from 1 × 10(-6) to 5 × 10(-6) for one type of filter paper and from 1 × 10(-6) to 1 × 10(-5) for a second type of filter paper, an effect not observed for materials tested at larger thicknesses. For high porosity materials, increasing chamber transport-limited deposition velocities resulted in increases in reaction probabilities by factors of 1.4-2.0. The impact of physical properties and transport effects on values of the Thiele modulus, ranging across all materials from 0.03 to 13, is discussed in terms of the challenges in estimating reaction probabilities to porous materials in scenarios relevant to indoor environments.
Collapse
Affiliation(s)
- Elliott T Gall
- Nanyang Technological University and Berkeley Education Alliance for Research in Singapore , Singapore 639798
| | | | | |
Collapse
|
138
|
Demirel G, Ozden O, Döğeroğlu T, Gaga EO. Personal exposure of primary school children to BTEX, NO₂ and ozone in Eskişehir, Turkey: relationship with indoor/outdoor concentrations and risk assessment. THE SCIENCE OF THE TOTAL ENVIRONMENT 2014; 473-474:537-548. [PMID: 24388904 DOI: 10.1016/j.scitotenv.2013.12.034] [Citation(s) in RCA: 93] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/11/2013] [Accepted: 12/08/2013] [Indexed: 05/28/2023]
Abstract
Personal exposures of 65 primary school children to benzene, toluene, ethyl benzene, xylenes (BTEX), nitrogen dioxide (NO2) and ozone (O3) were measured during 24h by using organic vapor monitors and tailor-made passive samplers. Two schools were selected to represent students living in more polluted (urban) and less polluted (sub-urban) areas in the city of Eskişehir, Turkey. The pollutant concentrations were also measured in indoor and outdoor environments during the personal sampling to investigate the contribution of each micro-environment on measured personal concentrations. Socio-demographic and personal time-activity data were collected by means of questionnaires and half-hour-time resolution activity diaries. Personal exposure concentrations were found to be correlated with indoor home concentrations. Personal, indoor and outdoor concentrations of all studied pollutants except for ozone were found to be higher for the students living at the urban traffic site. Ozone, on the other hand, had higher concentrations at the sub-urban site for all three types of measurements (personal, indoor and outdoor). Analysis of the questionnaire data pointed out to environmental tobacco smoke, use of solvent based products, and petrol station nearby as factors that affect personal exposure concentrations. Cancer and non-cancer risks were estimated using the personal exposure concentrations. The mean cancer risk for the urban school children (1.7×10(-5)) was found to be higher than the sub-urban school children (0.88×10(-5)). Children living with smoking parents had higher risk levels (1.7×10(-5)) than children living with non-smoking parents (1.08×10(-5)). Overall, the risk levels were <1×10(-4). All hazard quotient values for BTEX for the non-cancer health effects were <1 based on the calculations EPA's Risk Assessment Guidance for Superfund (RAGS) part F.
Collapse
Affiliation(s)
- Gülçin Demirel
- Anadolu University, Faculty of Engineering, Department of Environmental Engineering, 26555 Eskişehir, Turkey.
| | - Ozlem Ozden
- Anadolu University, Faculty of Engineering, Department of Environmental Engineering, 26555 Eskişehir, Turkey.
| | - Tuncay Döğeroğlu
- Anadolu University, Faculty of Engineering, Department of Environmental Engineering, 26555 Eskişehir, Turkey.
| | - Eftade O Gaga
- Anadolu University, Faculty of Engineering, Department of Environmental Engineering, 26555 Eskişehir, Turkey.
| |
Collapse
|
139
|
Schick SF, Farraro KF, Perrino C, Sleiman M, van de Vossenberg G, Trinh MP, Hammond SK, Jenkins BM, Balmes J. Thirdhand cigarette smoke in an experimental chamber: evidence of surface deposition of nicotine, nitrosamines and polycyclic aromatic hydrocarbons and de novo formation of NNK. Tob Control 2014; 23:152-9. [PMID: 23716171 DOI: 10.1136/tobaccocontrol-2012-050915] [Citation(s) in RCA: 65] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
BACKGROUND A growing body of evidence shows that secondhand cigarette smoke undergoes numerous chemical changes after it is released into the air: it can adsorb to indoor surfaces, desorb back into the air and undergo chemical changes as it ages. OBJECTIVES To test the effects of aging on the concentration of polycyclic aromatic hydrocarbons (PAHs), nicotine and tobacco-specific nitrosamines in cigarette smoke. METHODS We generated sidestream and mainstream cigarette smoke with a smoking machine, diluted it with conditioned filtered air, and passed it through a 6 m(3) flow reactor with air exchange rates that matched normal residential air exchange rates. We tested the effects of 60 min aging on the concentration of 16 PAHs, nicotine, cotinine and tobacco-specific nitrosamines. We also measured sorption and deposition of nicotine, cotinine and tobacco-specific nitrosamines on materials placed within the flow reactor. RESULTS We observed mass losses of 62% for PAHs, 72%, for nicotine, 79% for N-nitrosonornicotine and 80% for 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK). Extraction of cotton cloth exposed to smoke yielded nicotine and NNK. The ratio of NNK:nicotine on the exposed cloth was 10-fold higher than that in aerosol samples. CONCLUSIONS Our data suggest that the majority of the PAHs, nicotine, cotinine and tobacco-specific nitrosamines that are released during smoking in homes and public places deposit on room surfaces. These data give an estimate of the potential for accumulation of carcinogens in thirdhand cigarette smoke. Exposure to PAHs and tobacco-specific nitrosamines, through dermal absorption and inhalation of contaminated dust, may contribute to smoking-attributable morbidity and mortality.
Collapse
Affiliation(s)
- Suzaynn F Schick
- Department of Medicine, University of California, , San Francisco, California, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
140
|
The effects of Mn loading on the structure and ozone decomposition activity of MnOx supported on activated carbon. CHINESE JOURNAL OF CATALYSIS 2014. [DOI: 10.1016/s1872-2067(12)60756-6] [Citation(s) in RCA: 65] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
141
|
Rai AC, Guo B, Lin CH, Zhang J, Pei J, Chen Q. Ozone reaction with clothing and its initiated VOC emissions in an environmental chamber. INDOOR AIR 2014; 24:49-58. [PMID: 23841649 DOI: 10.1111/ina.12058] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/21/2013] [Accepted: 06/28/2013] [Indexed: 05/03/2023]
Abstract
Human health is adversely affected by ozone and the volatile organic compounds (VOCs) produced from its reactions in the indoor environment. Hence, it is important to characterize the ozone-initiated reactive chemistry under indoor conditions and study the influence of different factors on these reactions. This investigation studied the ozone reactions with clothing through a series of experiments conducted in an environmental chamber under various conditions. The study found that the ozone reactions with a soiled (human-worn) T-shirt consumed ozone and generated VOCs. The ozone removal rate and deposition velocity for the T-shirt increased with the increasing soiling level and air change rate, decreased at high ozone concentrations, and were relatively unaffected by the humidity. The deposition velocity for the soiled T-shirt ranged from 0.15 to 0.29 cm/s. The ozone-initiated VOC emissions included C6-C10 straight-chain saturated aldehydes, acetone, and 4-OPA (4-oxopentanal). The VOC emissions were generally higher at higher ozone, humidity, soiling of T-shirt, and air change rate. The total molar yield was approximately 0.5 in most cases, which means that for every two moles of ozone removed by the T-shirt surface, one mole of VOCs was produced.
Collapse
Affiliation(s)
- A C Rai
- School of Mechanical Engineering, Purdue University, West Lafayette, IN, USA
| | | | | | | | | | | |
Collapse
|
142
|
Yu KP, Lee GWM, Hung AJ. Removal of indoor α-pinene with a fiber optic illuminated honeycomb monolith photocatalytic reactor. JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH. PART A, TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING 2014; 49:1110-1115. [PMID: 24844891 DOI: 10.1080/10934529.2014.897146] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
This study was undertaken to investigate the influencing factors including gas flow rate, inlet α-pinene concentration and relative humidity on the removal of α-pinene in a Degussa P25 supported honeycomb monolith reactor. We used the fiber optic illumination to enhance the intensity of UV-light irradiating on the Degussa P25 photocatalyst. The α-pinene conversion increased with the increase of gas flow rate indicating that the reaction rate was associated with the gaseous phase mass transfer. The α-pinene conversion varied between 91% and 96% in the range of inlet α-pinene concentration (400-2400 ppb) and relative humidity (30-70%) examined. The kinetics fits the Langmuir-Hinshelwood model. The rate coefficient (k) of α-pinene under RH30%, 50% and 70% was 0.82, 0.24, and 0.18 μmol m(-2)s(-1), respectively. The competitive Langmuir adsorption constants for α-pinene under RH30%, 50% and 70% were 0.17, 0.56 and 1.74 ppm(-1), respectively. The effect of relative humidity on α-pinene conversion depends on the inlet α-pinene concentration and raising relative humidity in sum has a positive effect on the reduction of partially oxidized intermediates within the range investigated.
Collapse
Affiliation(s)
- Kuo-Pin Yu
- a Institute of Environmental and Occupational Health Science, National Yang-Ming University , Taipei , Taiwan
| | | | | |
Collapse
|
143
|
Ayoko GA, Wang H. Volatile Organic Compounds in Indoor Environments. THE HANDBOOK OF ENVIRONMENTAL CHEMISTRY 2014. [DOI: 10.1007/698_2014_259] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
|
144
|
Sarnat JA, Sarnat SE, Flanders WD, Chang HH, Mulholland J, Baxter L, Isakov V, Özkaynak H. Spatiotemporally resolved air exchange rate as a modifier of acute air pollution-related morbidity in Atlanta. JOURNAL OF EXPOSURE SCIENCE & ENVIRONMENTAL EPIDEMIOLOGY 2013; 23:606-15. [PMID: 23778234 DOI: 10.1038/jes.2013.32] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/10/2012] [Accepted: 02/26/2013] [Indexed: 05/04/2023]
Abstract
Epidemiological studies frequently use central site concentrations as surrogates of exposure to air pollutants. Variability in air pollutant infiltration due to differential air exchange rates (AERs) is potentially a major factor affecting the relationship between central site concentrations and actual exposure, and may thus influence observed health risk estimates. In this analysis, we examined AER as an effect modifier of associations between several urban air pollutants and corresponding emergency department (ED) visits for asthma and wheeze during a 4-year study period (January 1999-December 2002) for a 186 ZIP code area in metro Atlanta. We found positive associations for the interaction between AER and pollution on asthma ED visits for both carbon monoxide (CO) and nitrogen oxides (NO(x)), indicating significant or near-significant effect modification by AER on the pollutant risk-ratio estimates. In contrast, the interaction term between particulate matter (PM)(2.5) and AER on asthma ED visits was negative and significant. However, alternative distributional tertile analyses showed PM(2.5) and AER epidemiological model results to be similar to those found for NOx and CO (namely, increasing risk ratios (RRs) with increasing AERs when ambient PM(2.5) concentrations were below the highest tertile of their distribution). Despite the fact that ozone (O(3)) was a strong independent predictor of asthma ED visits in our main analysis, we found no O(3)-AER effect modification. To our knowledge, our findings for CO, NOx, and PM(2.5) are the first to provide an indication of short-term (i.e., daily) effect modification of multiple air pollution-related risk associations with daily changes in AER. Although limited to one outcome category in a single large urban locale, the findings suggest that the use of relatively simple and easy-to-derive AER surrogates may reflect intraurban differences in short-term exposures to pollutants of ambient origin.
Collapse
Affiliation(s)
- Jeremy A Sarnat
- Department of Environmental Health, Rollins School of Public Health, Emory University, Atlanta, Georgia, USA
| | | | | | | | | | | | | | | |
Collapse
|
145
|
Rohr AC. The health significance of gas- and particle-phase terpene oxidation products: a review. ENVIRONMENT INTERNATIONAL 2013; 60:145-162. [PMID: 24036325 DOI: 10.1016/j.envint.2013.08.002] [Citation(s) in RCA: 63] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/03/2013] [Revised: 08/01/2013] [Accepted: 08/02/2013] [Indexed: 06/02/2023]
Abstract
The reactions between terpenes and ozone (or other oxidants) produce a wide variety of both gas- and particle-phase products. Terpenes are biogenic volatile organic compounds (VOCs) that are also contained in many consumer products. Ozone is present indoors since it infiltrates into the indoor environment and is emitted by some office and consumer equipment. Some of the gaseous products formed are irritating to biological tissues, while the condensed-phase products have received attention due to their contribution to ambient fine particulate matter (PM2.5) and its respective health significance. Despite common scientific questions, the indoor and ambient air research communities have tended to operate in isolation regarding this topic. This review critically evaluates the literature related to terpene oxidation products and attempts to synthesize results of indoor and ambient air studies to better understand the health significance of these materials and identify knowledge gaps. The review documents the results of a literature search covering terpene oxidation chemistry, epidemiological, toxicological, and controlled human exposure studies, as well as health studies focused more generically on secondary organic aerosol (SOA). The literature shows a clear role for gas-phase terpene oxidation products in adverse airway effects at high concentrations; however, whether these effects occur at more environmentally relevant levels is unclear. The evidence for toxicity of particle-phase products is less conclusive. Knowledge gaps and future research needs are outlined, and include the need for more consistency in study designs, incorporation of reaction product measurements into epidemiological studies conducted in both indoor and ambient settings, and more focused research on the toxicity of SOA, especially SOA of biogenic origin.
Collapse
Affiliation(s)
- Annette C Rohr
- Electric Power Research Institute, Palo Alto, CA, United States.
| |
Collapse
|
146
|
|
147
|
Zhang Y, Mo J, Weschler CJ. Reducing health risks from indoor exposures in rapidly developing urban China. ENVIRONMENTAL HEALTH PERSPECTIVES 2013; 121:751-5. [PMID: 23665813 PMCID: PMC3701998 DOI: 10.1289/ehp.1205983] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/06/2012] [Accepted: 04/23/2013] [Indexed: 05/21/2023]
Abstract
BACKGROUND Over the past two decades there has been a large migration of China's population from rural to urban regions. At the same time, residences in cities have changed in character from single-story or low-rise buildings to high-rise structures constructed and furnished with many synthetic materials. As a consequence, indoor exposures (to pollutants with outdoor and indoor sources) have changed significantly. OBJECTIVES We briefly discuss the inferred impact that urbanization and modernization have had on indoor exposures and public health in China. We argue that growing adverse health costs associated with these changes are not inevitable, and we present steps that could be taken to reduce indoor exposures to harmful pollutants. DISCUSSION As documented by China's Ministry of Health, there have been significant increases in morbidity and mortality among urban residents over the past 20 years. Evidence suggests that the population's exposure to air pollutants has contributed to increases in lung cancer, cardiovascular disease, pulmonary disease, and birth defects. Whether a pollutant has an outdoor or an indoor source, most exposure to the pollutant occurs indoors. Going forward, indoor exposures can be reduced by limiting the ingress of outdoor pollutants (while providing adequate ventilation with clean air), minimizing indoor sources of pollutants, updating government policies related to indoor pollution, and addressing indoor air quality during a building's initial design. CONCLUSIONS Taking the suggested steps could lead to significant reductions in morbidity and mortality, greatly reducing the societal costs associated with pollutant derived ill health.
Collapse
Affiliation(s)
- Yinping Zhang
- Department of Building Science, School of Architecture, Tsinghua University, Beijing, China
| | | | | |
Collapse
|
148
|
Fadeyi MO, Weschler CJ, Tham KW, Wu WY, Sultan ZM. Impact of human presence on secondary organic aerosols derived from ozone-initiated chemistry in a simulated office environment. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2013; 47:3933-3941. [PMID: 23488675 DOI: 10.1021/es3050828] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Several studies have documented reductions in indoor ozone levels that occur as a consequence of its reactions with the exposed skin, hair and clothing of human occupants. One would anticipate that consumption of ozone via such reactions would impact co-occurring products derived from ozone's reactions with various indoor pollutants. The present study examines this possibility for secondary organic aerosols (SOA) derived from ozone-initiated chemistry with limonene, a commonly occurring indoor terpene. The experiments were conducted at realistic ozone and limonene concentrations in a 240 m(3) chamber configured to simulate a typical open office environment. During an experiment the chamber was either unoccupied or occupied with 18-20 workers. Ozone and particle levels were continuously monitored using a UV photometric ozone analyzer and a fast mobility particle sizer (FMPS), respectively. Under otherwise identical conditions, when workers were present in the simulated office the ozone concentrations were approximately two-thirds and the SOA mass concentrations were approximately one-half of those measured when the office was unoccupied. This was observed whether new or used filters were present in the air handling system. These results illustrate the importance of accounting for occupancy when estimating human exposure to pollutants in various indoor settings.
Collapse
Affiliation(s)
- Moshood O Fadeyi
- Faculty of Engineering and IT, British University in Dubai, P.O. Box 345015, Dubai, United Arab Emirates.
| | | | | | | | | |
Collapse
|
149
|
Dambruoso PR, de Gennaro G, Loiotile AD, Di Gilio A, Giungato P, Marzocca A, Mazzone A, Palmisani J, Porcelli F, Tutino M. School Air Quality: Pollutants, Monitoring and Toxicity. ENVIRONMENTAL CHEMISTRY FOR A SUSTAINABLE WORLD 2013. [DOI: 10.1007/978-3-319-02387-8_1] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
|
150
|
How much evidence is enough? Assessing home asthma research. JOURNAL OF PUBLIC HEALTH MANAGEMENT AND PRACTICE 2012; 16:S21-3. [PMID: 20689370 DOI: 10.1097/phh.0b013e3181ee0af3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|