1
|
Jeon EB, Roy A, Park SY. Application of sodium hypochlorite for human norovirus and hepatitis A virus inactivation in groundwater. Appl Environ Microbiol 2024:e0140524. [PMID: 39480096 DOI: 10.1128/aem.01405-24] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2024] [Accepted: 09/26/2024] [Indexed: 11/02/2024] Open
Abstract
In this study, the effect of sodium hypochlorite (10-200 ppm of Cl2) on the inactivation of human norovirus (HuNV) GII.4 and hepatitis A virus (HAV) in groundwater was investigated using propidium monoazide (PMA)/reverse transcription quantitative real-time PCR (RT-qPCR). Initially, 4.00 log10 genome copies/μL of HuNV GII.4 or 5.50 log10 genome copies/μL of HAV were artificially inoculated in groundwater. The titers of HuNV GII.4 and HAV decreased significantly (P < 0.05) with increasing Cl2 concentrations. Groundwater was treated with 10, 30, 50, 100, 150, and 200 ppm of Cl2, and the viable HuNV GII.4 was significantly (P < 0.05) reduced to 3.28 (0.21-log reduction), 3.18 (0.31-log reduction), 3.01 (0.48 log reduction), 2.75 (0.74 log reduction), 2.54 (0.95 log reduction), and 2.34 (1.15 log reduction) log10 genome copies/μL, respectively. The viable HAV was also significantly (P < 0.05) reduced to 4.99 (0.23 log reduction), 4.76 (0.46 log reduction), 4.55 (0.67 log reduction), 4.21 (1.01-log reduction), 3.89 (1.33 log reduction), and 3.64 (1.58 log reduction) log10 genome copies/μL, respectively. The decimal reduction times (D values) (1-log10 genome reduction) of HuNV GII.4 and HAV infectivity in groundwater were predicted as 116.7 and 98.9 ppm of Cl2, respectively, using the first-order kinetics model (HuNV GII.4: y = -0.0054x + 3.3585, correlation coefficient (R2) = 0.97; HAV: y = -0.0091x + 5.0470, R2 = 0.97). The result specifically suggests that 150- to 200-ppm Cl2 can potentially be used for the inactivation of >1-log10 genome copy/μL HuNV GII.4 and HAV in groundwater.IMPORTANCEGroundwater represents a vital component of the global water supply, serving as a crucial source of potable water for humans. It serves as a source of potable water for up to 50% of the global population and accounts for 43% of all water used for irrigation. It thus follows that the sustainable management of groundwater represents a pivotal solution. However, the regrowth of pathogens in water that is not treated with chlorine or where proper residual chlorine is not maintained represents a risk to public health.
Collapse
Affiliation(s)
- Eun Bi Jeon
- Department of Seafood Science and Technology, Institute of Marine Industry, Gyeongsang National University, Tongyeong, South Korea
| | - Anamika Roy
- Department of Seafood Science and Technology, Institute of Marine Industry, Gyeongsang National University, Tongyeong, South Korea
| | - Shin Young Park
- Department of Seafood Science and Technology, Institute of Marine Industry, Gyeongsang National University, Tongyeong, South Korea
| |
Collapse
|
2
|
Chaplin M, Leung K, Szczuka A, Hansen B, Rockey NC, Henderson JB, Wigginton KR. Linear Mixed Model of Virus Disinfection by Free Chlorine to Harmonize Data Collected across Broad Environmental Conditions. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2024; 58:12260-12271. [PMID: 38923944 PMCID: PMC11238732 DOI: 10.1021/acs.est.4c02885] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/21/2024] [Revised: 05/30/2024] [Accepted: 05/31/2024] [Indexed: 06/28/2024]
Abstract
Despite the critical importance of virus disinfection by chlorine, our fundamental understanding of the relative susceptibility of different viruses to chlorine and robust quantitative relationships between virus disinfection rate constants and environmental parameters remains limited. We conducted a systematic review of virus inactivation by free chlorine and used the resulting data set to develop a linear mixed model that estimates chlorine inactivation rate constants for viruses based on experimental conditions. 570 data points were collected in our systematic review, representing 82 viruses over a broad range of environmental conditions. The harmonized inactivation rate constants under reference conditions (pH = 7.53, T = 20 °C, [Cl-] < 50 mM) spanned 5 orders of magnitude, ranging from 0.0196 to 1150 L mg-1 min-1, and uncovered important trends between viruses. Whereas common surrogate bacteriophage MS2 does not serve as a conservative chlorine disinfection surrogate for many human viruses, CVB5 was one of the most resistant viruses in the data set. The model quantifies the role of pH, temperature, and chloride levels across viruses, and an online tool allows users to estimate rate constants for viruses and conditions of interest. Results from the model identified potential shortcomings in current U.S. EPA drinking water disinfection requirements.
Collapse
Affiliation(s)
- Mira Chaplin
- Civil
and Environmental Engineering, University
of Michigan, 1351 Beal Ave., Ann Arbor, Michigan 48109-2138, United States
| | - Kaming Leung
- Civil
and Environmental Engineering, University
of Michigan, 1351 Beal Ave., Ann Arbor, Michigan 48109-2138, United States
| | - Aleksandra Szczuka
- Civil
and Environmental Engineering, University
of Michigan, 1351 Beal Ave., Ann Arbor, Michigan 48109-2138, United States
| | - Brianna Hansen
- Civil
and Environmental Engineering, University
of Michigan, 1351 Beal Ave., Ann Arbor, Michigan 48109-2138, United States
| | - Nicole C. Rockey
- Civil
and Environmental Engineering, Duke University, Durham, North Carolina, 27708, United States
| | - James B. Henderson
- Department
of Internal Medicine, University of Michigan
Medical School, NCRC Bldg. 16 #471C, 2800 Plymouth Rd., Ann
Arbor, Michigan 48109-2138, United States
| | - Krista R. Wigginton
- Civil
and Environmental Engineering, University
of Michigan, 1351 Beal Ave., Ann Arbor, Michigan 48109-2138, United States
| |
Collapse
|
3
|
Miura T, Kadoya SS, Miura Y, Takino H, Akiba M, Sano D, Masuda T. Pepper mild mottle virus intended for use as a process indicator for drinking water treatment: Present forms and quantitative relations to norovirus and rotavirus in surface water. WATER RESEARCH 2024; 257:121713. [PMID: 38733963 DOI: 10.1016/j.watres.2024.121713] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/06/2023] [Revised: 03/19/2024] [Accepted: 05/01/2024] [Indexed: 05/13/2024]
Abstract
Pepper mild mottle virus (PMMoV) has been proposed as a potential indicator of human enteric viruses in environmental water and for viral removal during drinking water treatment. To investigate the occurrence and present forms of PMMoV and quantitative relations to norovirus GII and rotavirus A (RVA) in surface waters, 147 source water samples were collected from 21 drinking water treatment plants (DWTPs) in Japan between January 2018 and January 2021, and the concentrations of viruses in suspended and dissolved fractions were measured using real-time RT-PCR. PMMoV was detected in 81-100 % of samples in each sample month and observed concentrations ranged from 3.0 to 7.0 log10 copies/L. The concentrations of PMMoV were higher in dissolved fraction compared to suspended fractions, while different partitioning was observed for NoV GII depending on seasons. The concentrations of PMMoV were basically higher than those of norovirus GII (1.9-5.3 log10 copies/L) and RVA (1.9-6.6 log10 copies/L), while in 18 samples, RVA presented higher concentrations than PMMoV. Partial regions of VP7, VP4, and VP6 of the RVA in the 18 samples were amplified using nested PCR, and the genotypes were determined using an amplicon-based next-generation sequencing approach. We found that these source water samples included not only human RVA but also various animal RVA and high genetic diversity due to the existence of animal RVA was associated with a higher RVA concentration than PMMoV. Our findings suggest that PMMoV can be used as an indicator of norovirus GII and human RVA in drinking water sources and that the indicator performance should be evaluated by comparing to zoonotic viruses as well as human viruses.
Collapse
Affiliation(s)
- Takayuki Miura
- Department of Environmental Health, National Institute of Public Health, Wako, Japan.
| | - Syun-Suke Kadoya
- Department of Civil and Environmental Engineering, Tohoku University, Japan; Department of Urban Engineering, The University of Tokyo, Japan
| | - Yohei Miura
- Department of Civil and Environmental Engineering, Tohoku University, Japan
| | - Hiroyuki Takino
- Department of Environmental Health, National Institute of Public Health, Wako, Japan
| | - Michihiro Akiba
- Department of Environmental Health, National Institute of Public Health, Wako, Japan
| | - Daisuke Sano
- Department of Civil and Environmental Engineering, Tohoku University, Japan
| | | |
Collapse
|
4
|
Sun H, Zhou ZJ, Wen HQ, Chen FF, Pan Y, Tang Q, Yu HQ. Deciphering the Roles of Extracellular Polymeric Substances (EPS) in Shaping Disinfection Kinetics through Permanent Removal via Genetic Disruption. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2024; 58:6552-6563. [PMID: 38571383 DOI: 10.1021/acs.est.4c01612] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/05/2024]
Abstract
Extracellular polymeric substances (EPS) ubiquitously encapsulate microbes and play crucial roles in various environmental processes. However, understanding their complex interactions with dynamic bacterial behaviors, especially during the disinfection process, remains very limited. In this work, we investigated the impact of EPS on bacterial disinfection kinetics by developing a permanent EPS removal strategy. We genetically disrupted the synthesis of exopolysaccharides, the structural components of EPS, in Pseudomonas aeruginosa, a well-known EPS-producing opportunistic pathogen found in diverse environments, creating an EPS-deficient strain. This method ensured a lasting absence of EPS while maintaining bacterial integrity and viability, allowing for real-time in situ investigations of the roles of EPS in disinfection. Our findings indicate that removing EPS from bacteria substantially lowered their susceptibility threshold to disinfectants such as ozone, chloramine B, and free chlorine. This removal also substantially accelerated disinfection kinetics, shortened the resistance time, and increased disinfection efficiency, thereby enhancing the overall bactericidal effect. The absence of EPS was found to enhance bacterial motility and increase bacterial cell vulnerability to disinfectants, resulting in greater membrane damage and intensified reactive oxygen species (ROS) production upon exposure to disinfectants. These insights highlight the central role of EPS in bacterial defenses and offer promising implications for developing more effective disinfection strategies.
Collapse
|
5
|
Torii S, Gouttenoire J, Kumar K, Antanasijevic A, Kohn T. Influence of Amino Acid Substitutions in Capsid Proteins of Coxsackievirus B5 on Free Chlorine and Thermal Inactivation. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2024; 58:5279-5289. [PMID: 38488515 DOI: 10.1021/acs.est.3c10409] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/27/2024]
Abstract
The sensitivity of enteroviruses to disinfectants varies among genetically similar variants and coincides with amino acid changes in capsid proteins, although the effect of individual substitutions remains unknown. Here, we employed reverse genetics to investigate how amino acid substitutions in coxsackievirus B5 (CVB5) capsid proteins affect the virus' sensitivity to free chlorine and heat treatment. Of ten amino acid changes observed in CVB5 variants with free chlorine resistance, none significantly reduced the chlorine sensitivity, indicating a minor role of the capsid composition in chlorine sensitivity of CVB5. Conversely, a subset of these amino acid changes located at the C-terminal region of viral protein 1 led to reduced heat sensitivity. Cryo-electron microscopy revealed that these changes affect the assembly of intermediate viral states (altered and empty particles), suggesting that the mechanism for reduced heat sensitivity could be related to improved molecular packing of CVB5, resulting in greater stability or altered dynamics of virus uncoating during infection.
Collapse
Affiliation(s)
- Shotaro Torii
- Laboratory of Environmental Chemistry, School of Architecture, Civil and Environmental Engineering (ENAC), École Polytechnique Fédérale de Lausanne (EPFL), CH-1015 Lausanne, Switzerland
| | - Jérôme Gouttenoire
- Division of Gastroenterology and Hepatology, Lausanne University Hospital and University of Lausanne, CH-1011 Lausanne, Switzerland
| | - Kiruthika Kumar
- Virology and Structural Immunology Laboratory, School of Life Sciences, École Polytechnique Fédérale de Lausanne (EPFL), CH-1015 Lausanne, Switzerland
| | - Aleksandar Antanasijevic
- Virology and Structural Immunology Laboratory, School of Life Sciences, École Polytechnique Fédérale de Lausanne (EPFL), CH-1015 Lausanne, Switzerland
| | - Tamar Kohn
- Laboratory of Environmental Chemistry, School of Architecture, Civil and Environmental Engineering (ENAC), École Polytechnique Fédérale de Lausanne (EPFL), CH-1015 Lausanne, Switzerland
| |
Collapse
|
6
|
Heffron J, Samsami M, Juedemann S, Lavin J, Tavakoli Nick S, Kieke BA, Mayer BK. Mitigation of viruses of concern and bacteriophage surrogates via common unit processes for water reuse: A meta-analysis. WATER RESEARCH 2024; 252:121242. [PMID: 38342066 DOI: 10.1016/j.watres.2024.121242] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/01/2023] [Revised: 01/26/2024] [Accepted: 01/30/2024] [Indexed: 02/13/2024]
Abstract
Water reuse is a growing global reality. In regulating water reuse, viruses have come to the fore as key pathogens due to high shedding rates, low infectious doses, and resilience to traditional wastewater treatments. To demonstrate the high log reductions required by emerging water reuse regulations, cost and practicality necessitate surrogates for viruses for use as challenge organisms in unit process evaluation and monitoring. Bacteriophage surrogates that are mitigated to the same or lesser extent than viruses of concern are routinely used for individual unit process testing. However, the behavior of these surrogates over a multi-barrier treatment train typical of water reuse has not been well-established. Toward this aim, we performed a meta-analysis of log reductions of common bacteriophage surrogates for five treatment processes typical of water reuse treatment trains: advanced oxidation processes, chlorination, membrane filtration, ozonation, and ultraviolet (UV) disinfection. Robust linear regression was applied to identify a range of doses consistent with a given log reduction of bacteriophages and viruses of concern for each treatment process. The results were used to determine relative conservatism of surrogates. We found that no one bacteriophage was a representative or conservative surrogate for viruses of concern across all multi-barrier treatments (encompassing multiple mechanisms of virus mitigation). Rather, a suite of bacteriophage surrogates provides both a representative range of inactivation and information about the effectiveness of individual processes within a treatment train. Based on the abundance of available data and diversity of virus treatability using these five key water reuse treatment processes, bacteriophages MS2, phiX174, and Qbeta were recommended as a core suite of surrogates for virus challenge testing.
Collapse
Affiliation(s)
- Joe Heffron
- U.S. Department of Agriculture-Agricultural Research Service, Environmentally Integrated Dairy Management Research Unit, 2615 Yellowstone Dr., Marshfield, WI 54449, USA.
| | - Maryam Samsami
- Department of Civil, Construction and Environmental Engineering, Marquette University, 1637 West Wisconsin Avenue, Milwaukee, WI 53233, USA
| | - Samantha Juedemann
- Department of Civil, Construction and Environmental Engineering, Marquette University, 1637 West Wisconsin Avenue, Milwaukee, WI 53233, USA
| | - Jennifer Lavin
- Department of Civil, Construction and Environmental Engineering, Marquette University, 1637 West Wisconsin Avenue, Milwaukee, WI 53233, USA
| | - Shadi Tavakoli Nick
- Department of Civil, Construction and Environmental Engineering, Marquette University, 1637 West Wisconsin Avenue, Milwaukee, WI 53233, USA
| | - Burney A Kieke
- Marshfield Clinic Research Institute, Center for Clinical Epidemiology and Population Health, 1000 N Oak Ave., Marshfield, WI 54449, USA
| | - Brooke K Mayer
- Department of Civil, Construction and Environmental Engineering, Marquette University, 1637 West Wisconsin Avenue, Milwaukee, WI 53233, USA
| |
Collapse
|
7
|
Cong W, Pike A, Gonçalves K, Shisler JL, Mariñas BJ. Inactivation Kinetics and Replication Cycle Inhibition of Coxsackievirus B5 by Free Chlorine. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2023; 57:18690-18699. [PMID: 36946773 DOI: 10.1021/acs.est.2c09269] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
The kinetics of coxsackievirus serotype B5 (CVB5) inactivation with free chlorine is characterized over a range of pH and temperature relevant to drinking water treatment with the primary goal of selecting experimental conditions used for assessing inactivation mechanisms. The inactivation kinetics identified in our study is similar to or slower than experimental data reported in the literature and thus provides a conservative representation of the kinetics of CVB5 inactivation for free chlorine that could be useful in developing future regulations for waterborne viral pathogens including adequate disinfection treatment for CVB5. Untreated and free chlorine-treated viruses, and host cells synchronized-infected with these viruses, are analyzed by a reverse transcription-quantitative polymerase chain reaction (RT-qPCR) method with the goal of quantitatively investigating the effect of free chlorine exposure on viral genome integrity, attachment to host cell, and viral genome replication. The inactivation kinetics observed results from a combination of hindering virus attachment to the host cell, inhibition of one or more subsequent steps of the replication cycle, and possibly genome damage.
Collapse
|
8
|
Torii S, David SC, Larivé O, Cariti F, Kohn T. Observed Kinetics of Enterovirus Inactivation by Free Chlorine Are Host Cell-Dependent. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2023; 57:18483-18490. [PMID: 36649532 DOI: 10.1021/acs.est.2c07048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Virucidal efficacies of disinfectants are typically assessed by infectivity assay utilizing a single type of host cell. Enteroviruses infect multiple host cells via various entry routes, and each entry route may be impaired differently by a given disinfectant. Yet, it is unknown how the choice of host cells affects the observed inactivation kinetics. Here, we evaluated the inactivation kinetics of echovirus 11 (E11) by free chlorine, ultraviolet (UV) irradiation, and heat, using three different host cells (BGMK, RD, and A549). Inactivation rates were independent of the host cell for treatment of E11 by UV or heat. Conversely, E11 inactivation by free chlorine occurred 2-fold faster when enumerated on BGMK cells compared with RD and A549 cells. Host cell-dependent inactivation kinetics by free chlorine were also observed for echovirus 7, 9, and 13, and coxsackievirus A9. E11 inactivation by free chlorine was partly caused by a loss in host cell attachment, which was most pronounced for BGMK cells. BGMK cells lack the attachment receptor CD55 and a key subunit of the uncoating receptor β2M, which may contribute to the differential inactivation kinetics for this cell type. Consequently, inactivation kinetics of enteroviruses should be assessed using host cells with different receptor profiles.
Collapse
Affiliation(s)
- Shotaro Torii
- Laboratory of Environmental Chemistry, School of Architecture, Civil and Environmental Engineering (ENAC), École Polytechnique Fédérale de Lausanne (EPFL), CH-1015Lausanne, Switzerland
| | - Shannon Christa David
- Laboratory of Environmental Chemistry, School of Architecture, Civil and Environmental Engineering (ENAC), École Polytechnique Fédérale de Lausanne (EPFL), CH-1015Lausanne, Switzerland
| | - Odile Larivé
- Laboratory of Environmental Chemistry, School of Architecture, Civil and Environmental Engineering (ENAC), École Polytechnique Fédérale de Lausanne (EPFL), CH-1015Lausanne, Switzerland
| | - Federica Cariti
- Laboratory of Environmental Chemistry, School of Architecture, Civil and Environmental Engineering (ENAC), École Polytechnique Fédérale de Lausanne (EPFL), CH-1015Lausanne, Switzerland
| | - Tamar Kohn
- Laboratory of Environmental Chemistry, School of Architecture, Civil and Environmental Engineering (ENAC), École Polytechnique Fédérale de Lausanne (EPFL), CH-1015Lausanne, Switzerland
| |
Collapse
|
9
|
Al-Hazmi HE, Mohammadi A, Hejna A, Majtacz J, Esmaeili A, Habibzadeh S, Saeb MR, Badawi M, Lima EC, Mąkinia J. Wastewater reuse in agriculture: Prospects and challenges. ENVIRONMENTAL RESEARCH 2023; 236:116711. [PMID: 37487927 DOI: 10.1016/j.envres.2023.116711] [Citation(s) in RCA: 19] [Impact Index Per Article: 19.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/28/2023] [Revised: 07/11/2023] [Accepted: 07/19/2023] [Indexed: 07/26/2023]
Abstract
Sustainable water recycling and wastewater reuse are urgent nowadays considering water scarcity and increased water consumption through human activities. In 2015, United Nations Sustainable Development Goal 6 (UN SDG6) highlighted the necessity of recycling wastewater to guarantee water availability for individuals. Currently, wastewater irrigation (WWI) of crops and agricultural land appears essential. The present work overviews the quality of treated wastewater in terms of soil microbial activities, and discusses challenges and benefits of WWI in line with wastewater reuse in agriculture and aquaculture irrigation. Combined conventional-advanced wastewater treatment processes are specifically deliberated, considering the harmful impacts on human health arising from WWI originating from reuse of contaminated water (salts, organic pollutants, toxic metals, and microbial pathogens i.e., viruses and bacteria). The comprehensive literature survey revealed that, in addition to the increased levels of pathogen and microbial threats to human wellbeing, poorly-treated wastewater results in plant and soil contamination with toxic organic/inorganic chemicals, and microbial pathogens. The impact of long-term emerging pollutants like plastic nanoparticles should also be established in further studies, with the development of standardized analytical techniques for such hazardous chemicals. Likewise, the reliable, long-term and extensive judgment on heavy metals threat to human beings's health should be explored in future investigations.
Collapse
Affiliation(s)
- Hussein E Al-Hazmi
- Department of Sanitary Engineering, Faculty of Civil and Environmental Engineering, Gdańsk University of Technology, ul. Narutowicza 11/12, 80-233, Gdańsk, Poland
| | - Ali Mohammadi
- Department of Engineering and Chemical Sciences, Karlstad University, 65188, Karlstad, Sweden.
| | - Aleksander Hejna
- Institute of Materials Technology, Poznan University of Technology, Poznań, Poland
| | - Joanna Majtacz
- Department of Sanitary Engineering, Faculty of Civil and Environmental Engineering, Gdańsk University of Technology, ul. Narutowicza 11/12, 80-233, Gdańsk, Poland
| | - Amin Esmaeili
- Department of Chemical Engineering, School of Engineering Technology and Industrial Trades, University of Doha for Science and Technology (UDST), 24449, Arab League St, Doha, Qatar
| | - Sajjad Habibzadeh
- Surface Reaction and Advanced Energy Materials Laboratory, Chemical Engineering Department, Amirkabir University of Technology (Tehran Polytechnic), Tehran, Iran
| | - Mohammad Reza Saeb
- Department of Polymer Technology, Faculty of Chemistry, Gdańsk University of Technology, G. Narutowicza 11/12, 80-233, Gdańsk, Poland.
| | - Michael Badawi
- Laboratoire de Physique et Chimie Théoriques UMR CNRS 7019, Université de Lorraine, Nancy, France
| | - Eder C Lima
- Institute of Chemistry, Federal University of Rio Grande Do Sul (UFRGS), Porto Alegre, RS, Brazil
| | - Jacek Mąkinia
- Department of Sanitary Engineering, Faculty of Civil and Environmental Engineering, Gdańsk University of Technology, ul. Narutowicza 11/12, 80-233, Gdańsk, Poland
| |
Collapse
|
10
|
Canh VD, Torii S, Singhopon T, Katayama H. Inactivation of coxsackievirus B5 by free chlorine under conditions relevant to drinking water treatment. JOURNAL OF WATER AND HEALTH 2023; 21:1318-1324. [PMID: 37756198 PMCID: wh_2023_178 DOI: 10.2166/wh.2023.178] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/29/2023]
Abstract
Chlorine disinfection is commonly applied to inactivate pathogenic viruses in drinking water treatment plants. However, the role of water quality in chlorine disinfection of viruses has not been investigated thoughtfully. In this study, we investigated the inactivation efficiency of coxsackievirus B5 (CVB5) by free chlorine using actual water samples collected from four full-scale drinking water treatment plants in Japan under strict turbidity management (less than 0.14 NTU) over a 12-month period. It was found that chlorine disinfection of CVB5 might not be affected by water quality. Japanese turbidity management might play an indirect role in controlling the efficiency of chlorine disinfection.
Collapse
Affiliation(s)
- Vu Duc Canh
- Department of Urban Engineering, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan E-mail:
| | - Shotaro Torii
- Department of Urban Engineering, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan; Laboratory of Environmental Chemistry, School of Architecture, Civil and Environmental Engineering (ENAC), École Polytechnique F ́ed ́erale de Lausanne (EPFL), Lausanne, Switzerland
| | - Tippawan Singhopon
- Department of Urban Engineering, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
| | - Hiroyuki Katayama
- Department of Urban Engineering, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan; Research Center for Water Environment Technology, Graduate School of Engineering, The University of Tokyo, Tokyo, Japan
| |
Collapse
|
11
|
Shirakawa D, Shirasaki N, Hu Q, Matsushita T, Matsui Y, Takagi H, Oka T. Investigation of removal and inactivation efficiencies of human sapovirus in drinking water treatment processes by applying an in vitro cell-culture system. WATER RESEARCH 2023; 236:119951. [PMID: 37060876 DOI: 10.1016/j.watres.2023.119951] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Revised: 04/04/2023] [Accepted: 04/06/2023] [Indexed: 06/19/2023]
Abstract
Here, we examined the efficiencies of drinking water treatment processes for the removal and inactivation of human sapovirus (HuSaV). We applied a recently developed in vitro cell-culture system to produce purified solutions of HuSaV containing virus concentrations high enough to conduct virus-spiking experiments, to develop an integrated cell culture-polymerase chain reaction (ICC-PCR) assay to quantify the infectivity of HuSaV, and to conduct virus-spiking experiments. In virus-spiking coagulation-sedimentation-rapid sand filtration (CS-RSF) and coagulation-microfiltration (C-MF) experiments, HuSaV removals of 1.6-3.7-log10 and 1.2->4.3-log10, respectively, were observed. The removal ratios observed with CS-RSF were comparable and correlated with those of murine norovirus (MNV, a widely used surrogate for human noroviruses) and pepper mild mottle virus (PMMoV, a potential surrogate for human enteric viruses in physical and physicochemical drinking water treatment processes), and those observed with C-MF were higher than but still correlated with those of MNV and PMMoV, indicating that MNV and PMMoV are both potential surrogates for HuSaV in CS-RSF and C-MF. For astrovirus (AstV, a representative human enteric virus), removal ratios of 1.8-3.3-log10 and 1.1->4.0-log10 were observed with CS-RSF and C-MF, respectively. The removal ratios of AstV observed with CS-RSF were comparable and correlated with those of PMMoV, and those observed with C-MF were higher than but still correlated with those of PMMoV, indicating that PMMoV is a potential surrogate for AstV in CS-RSF and C-MF. When the efficacy of chlorine treatment was examined by using the developed ICC-PCR assay, 3.8-4.0-log10 inactivation of HuSaV was observed at a CT value (free-chlorine concentration [C] multiplied by contact time [T]) of 0.02 mg-Cl2·min/L. The infectivity reduction ratios of HuSaV were comparable with those of MNV. For AstV, 1.3-1.7-log10 and >3.4-log10 inactivation, as evaluated by ICC-PCR, was observed at CT values of 0.02 and 0.09 mg-Cl2·min/L, respectively. These results indicate that HuSaV and AstV are both highly sensitive to chlorine treatment and more sensitive than a chlorine-resistant virus, coxsackievirus B5 (1.3-log10 inactivation at a CT value of 0.4 mg-Cl2·min/L, as evaluated by the ICC-PCR assay).
Collapse
Affiliation(s)
- D Shirakawa
- Division of Environmental Engineering, Faculty of Engineering, Hokkaido University, N13W8, Sapporo, 060-8628, Japan
| | - N Shirasaki
- Division of Environmental Engineering, Faculty of Engineering, Hokkaido University, N13W8, Sapporo, 060-8628, Japan.
| | - Q Hu
- Division of Environmental Engineering, Faculty of Engineering, Hokkaido University, N13W8, Sapporo, 060-8628, Japan
| | - T Matsushita
- Division of Environmental Engineering, Faculty of Engineering, Hokkaido University, N13W8, Sapporo, 060-8628, Japan
| | - Y Matsui
- Division of Environmental Engineering, Faculty of Engineering, Hokkaido University, N13W8, Sapporo, 060-8628, Japan
| | - H Takagi
- Management Department of Biosafety, Laboratory Animal and Pathogen Bank, National Institute of Infectious Diseases, Tokyo, 208-0011, Japan
| | - T Oka
- Department of Virology II, National Institute of Infectious Diseases, Tokyo, 208-0011, Japan
| |
Collapse
|
12
|
Larivé O, Torii S, Derlon N, Kohn T. Selective elimination of enterovirus genotypes by activated sludge and chlorination. ENVIRONMENTAL SCIENCE : WATER RESEARCH & TECHNOLOGY 2023; 9:1620-1633. [PMID: 37274621 PMCID: PMC10233425 DOI: 10.1039/d3ew00050h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/27/2023] [Accepted: 04/25/2023] [Indexed: 06/06/2023]
Abstract
Enteroviruses, which are commonly circulating viruses shed in the stool, are released into the sewage system and only partially removed or inactivated, resulting in the discharge of infectious enteroviruses into the environment. Activated sludge and chlorination remove or inactivate enterovirus genotypes to different extents, and thus have the potential to shape the population that will be discharged. The goal of this study was to evaluate how activated sludge and chlorination treatment shape an enterovirus population at the genotype level, using a population of eight genotypes commonly found in sewage: CVA9, CVB1, CVB2, CVB3, CVB4, CVB5, E25, E30. Our results show that the extent of inactivation varied among genotypes, but also across sludge samples. We find that the effluent of activated sludge systems will be depleted in CVA9, CVB1 and CVB2 while E25 together with CVB3, CVB4 and CVB5 will be prevalent. Furthermore, we found that microbial inactivation was the main mechanism of infectivity loss in the activated sludge, while adsorption to the sludge flocs was not significant. During effluent chlorination, we also observed that CVB5, CVB3 and to a lesser extent E25 were less susceptible to chlorination while E30 was readily inactivated, and activated sludge-derived EPS provided further protection against chlorination. This study contributes to a better understanding of the variability of sewage treatment efficacy against different enteroviruses.
Collapse
Affiliation(s)
- Odile Larivé
- Laboratory of Environmental Chemistry, School of Architecture, Civil and Environmental Engineering, École Polytechnique Fédérale de Lausanne (EPFL) CH-1015 Lausanne Switzerland +41 21 69 30891
| | - Shotaro Torii
- Laboratory of Environmental Chemistry, School of Architecture, Civil and Environmental Engineering, École Polytechnique Fédérale de Lausanne (EPFL) CH-1015 Lausanne Switzerland +41 21 69 30891
| | - Nicolas Derlon
- Eawag, Swiss Federal Institute of Aquatic Science and Technology Überlandstrasse 133 CH-8600 Dübendorf Switzerland
| | - Tamar Kohn
- Laboratory of Environmental Chemistry, School of Architecture, Civil and Environmental Engineering, École Polytechnique Fédérale de Lausanne (EPFL) CH-1015 Lausanne Switzerland +41 21 69 30891
| |
Collapse
|
13
|
Costa LRDC, Féris LA. Use of ozonation technology to combat viruses and bacteria in aquatic environments: problems and application perspectives for SARS-CoV-2. ENVIRONMENTAL TECHNOLOGY 2023; 44:2490-2502. [PMID: 35078388 DOI: 10.1080/09593330.2022.2034981] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Accepted: 01/17/2022] [Indexed: 06/08/2023]
Abstract
COVID-19 is a global health threat with a large number of confirmed cases and deaths worldwide. Person-to-person transmission through respiratory droplets and contact with aerosol-infected surfaces are the main ways in which the virus spreads. However, according to the updated literature, the new coronavirus (SARS-CoV-2) has also been detected in aqueous matrices, with the main route of transmission being feces and masks from patients diagnosed with the disease. Given the emergence of public health and environmental protection from the presence of lethal viruses and bacteria, this review article aims to report the major challenges associated with the application of ozonation in water contaminated with viruses and bacteria, in order to clarify whether these communities can survive or infect after the disinfection process and if it is efficient. Available data suggest that ozonation is able to increase the inactivation effect of microorganisms by about 50% in the logarithmic range, reducing infectivity. In addition, the evidence-based knowledge reported in this article is useful to support water and sanitation safety planning and to protect human health from exposure to cited contaminants through water.
Collapse
Affiliation(s)
| | - Liliana Amaral Féris
- Department of Chemical Engineering, Federal University of Rio Grande do Sul, Porto Alegre, RS, Brazil
| |
Collapse
|
14
|
Yasui M, Ikner L, Yonetani T, Liu M, Katayama H. Effects of surface hydrophobicity on the removal of F-specific RNA phages from reclaimed water by coagulation and ceramic membrane microfiltration. WATER SCIENCE AND TECHNOLOGY : A JOURNAL OF THE INTERNATIONAL ASSOCIATION ON WATER POLLUTION RESEARCH 2023; 87:2304-2314. [PMID: 37186632 PMCID: wst_2023_133 DOI: 10.2166/wst.2023.133] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
Microfiltration (MF) has been widely adopted as an advanced treatment process to reduce suspended solids and turbidity in treated wastewater effluents designated for potable reuse. Although microfilter pores are much larger than viruses, the addition of a coagulant upstream of a microfilter system can achieve stable virus removal. Ceramic membranes have a narrow pore size distribution to achieve the high removal of contaminants. This study aims to evaluate virus log reduction using bench-scale coagulation and ceramic membrane MF. To investigate the effects of differences in net surface hydrophobicity, 18 sewage-derived F-specific RNA phages (FRNAPHs) were used for batch hydrophobicity and coagulation-MF tests. The capability of bench-scale coagulation and ceramic membrane MF under continuous automated long-term operation was tested to remove the lab reference strain MS2 and three selected FRNAPH isolates which varied by surface property. Median virus log reduction values (LRVs) exceeding 6.2 were obtained for all three isolates and MS2. Although coagulation and hydrophobicity were positively correlated, the virus isolate demonstrating the lowest level of hydrophobicity and coagulation (genogroup I) still exhibited a high LRV. Thus, coagulation and ceramic membrane MF systems may serve as viable options for virus removal during water reclamation and advanced treatment.
Collapse
Affiliation(s)
- Midori Yasui
- Department of Urban Engineering, The University of Tokyo, Tokyo, Japan E-mail:
| | - Luisa Ikner
- Department of Environmental Science, The University of Arizona, Tucson, AZ, USA
| | | | - Miaomiao Liu
- Department of Urban Engineering, The University of Tokyo, Tokyo, Japan E-mail:
| | - Hiroyuki Katayama
- Department of Urban Engineering, The University of Tokyo, Tokyo, Japan E-mail:
| |
Collapse
|
15
|
Sahun M, Privat-Maldonado A, Lin A, De Roeck N, Van der Heyden L, Hillen M, Michiels J, Steenackers G, Smits E, Ariën KK, Jorens PG, Delputte P, Bogaerts A. Inactivation of SARS-CoV-2 and Other Enveloped and Non-Enveloped Viruses with Non-Thermal Plasma for Hospital Disinfection. ACS SUSTAINABLE CHEMISTRY & ENGINEERING 2023; 11:5206-5215. [PMID: 37034498 PMCID: PMC10068876 DOI: 10.1021/acssuschemeng.2c07622] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/24/2022] [Revised: 03/10/2023] [Indexed: 06/19/2023]
Abstract
As recently highlighted by the SARS-CoV-2 pandemic, viruses have become an increasing burden for health, global economy, and environment. The control of transmission by contact with contaminated materials represents a major challenge, particularly in hospital environments. However, the current disinfection methods in hospital settings suffer from numerous drawbacks. As a result, several medical supplies that cannot be properly disinfected are not reused, leading to severe shortages and increasing amounts of waste, thus prompting the search for alternative solutions. In this work, we report that non-thermal plasma (NTP) can effectively inactivate SARS-CoV-2 from non-porous and porous materials commonly found in healthcare facilities. We demonstrated that 5 min treatment with a dielectric barrier discharge NTP can inactivate 100% of SARS-CoV-2 (Wuhan and Omicron strains) from plastic material. Using porcine respiratory coronavirus (surrogate for SARS-CoV-2) and coxsackievirus B3 (highly resistant non-enveloped virus), we tested the NTP virucidal activity on hospital materials and obtained complete inactivation after 5 and 10 min, respectively. We hypothesize that the produced reactive species and local acidification contribute to the overall virucidal effect of NTP. Our results demonstrate the potential of dielectric barrier discharge NTPs for the rapid, efficient, and low-cost disinfection of healthcare materials.
Collapse
Affiliation(s)
- Maxime Sahun
- Plasma
Lab for Applications in Sustainability and Medicine—Antwerp
(PLASMANT), Department of Chemistry, University
of Antwerp, Universiteitsplein 1, 2610 Antwerp, Belgium
| | - Angela Privat-Maldonado
- Plasma
Lab for Applications in Sustainability and Medicine—Antwerp
(PLASMANT), Department of Chemistry, University
of Antwerp, Universiteitsplein 1, 2610 Antwerp, Belgium
- Center
for Oncological Research (CORE), Integrated Personalized & Precision
Oncology Network (IPPON), University of
Antwerp, Universiteitsplein
1, 2610 Antwerp, Belgium
| | - Abraham Lin
- Plasma
Lab for Applications in Sustainability and Medicine—Antwerp
(PLASMANT), Department of Chemistry, University
of Antwerp, Universiteitsplein 1, 2610 Antwerp, Belgium
- Center
for Oncological Research (CORE), Integrated Personalized & Precision
Oncology Network (IPPON), University of
Antwerp, Universiteitsplein
1, 2610 Antwerp, Belgium
| | - Naomi De Roeck
- Laboratory
for Microbiology, Parasitology and Hygiene (LMPH), Faculty of Pharmaceutical,
Biomedical and Veterinary Sciences, University
of Antwerp, Universiteitsplein
1, 2610 Antwerp, Belgium
| | - Lisa Van der Heyden
- Plasma
Lab for Applications in Sustainability and Medicine—Antwerp
(PLASMANT), Department of Chemistry, University
of Antwerp, Universiteitsplein 1, 2610 Antwerp, Belgium
- Center
for Oncological Research (CORE), Integrated Personalized & Precision
Oncology Network (IPPON), University of
Antwerp, Universiteitsplein
1, 2610 Antwerp, Belgium
| | - Michaël Hillen
- Industrial
Vision Lab (InViLab), Department of Electromechanical Engineering, University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium
| | - Johan Michiels
- Virology
Unit, Department of Biomedical Sciences, Institute of Tropical Medicine Antwerp, Nationalestraat 155, 2000 Antwerp, Belgium
| | - Gunther Steenackers
- Industrial
Vision Lab (InViLab), Department of Electromechanical Engineering, University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium
| | - Evelien Smits
- Center
for Oncological Research (CORE), Integrated Personalized & Precision
Oncology Network (IPPON), University of
Antwerp, Universiteitsplein
1, 2610 Antwerp, Belgium
| | - Kevin K. Ariën
- Laboratory
for Microbiology, Parasitology and Hygiene (LMPH), Faculty of Pharmaceutical,
Biomedical and Veterinary Sciences, University
of Antwerp, Universiteitsplein
1, 2610 Antwerp, Belgium
- Virology
Unit, Department of Biomedical Sciences, Institute of Tropical Medicine Antwerp, Nationalestraat 155, 2000 Antwerp, Belgium
| | - Philippe G. Jorens
- Department
of Intensive Care Medicine, Antwerp University
Hospital, Wilrijkstraat
10, 2650 Antwerp, Belgium
- Laboratory
of Experimental Medicine and Pediatrics (LEMP), University of Antwerp, Universiteitsplein 1, 2610 Antwerp, Belgium
| | - Peter Delputte
- Laboratory
for Microbiology, Parasitology and Hygiene (LMPH), Faculty of Pharmaceutical,
Biomedical and Veterinary Sciences, University
of Antwerp, Universiteitsplein
1, 2610 Antwerp, Belgium
| | - Annemie Bogaerts
- Plasma
Lab for Applications in Sustainability and Medicine—Antwerp
(PLASMANT), Department of Chemistry, University
of Antwerp, Universiteitsplein 1, 2610 Antwerp, Belgium
| |
Collapse
|
16
|
Forés E, Mejías-Molina C, Ramos A, Itarte M, Hundesa A, Rusiñol M, Martínez-Puchol S, Esteve-Bricullé P, Espejo-Valverde A, Sirés I, Calvo M, Araujo RM, Girones R. Evaluation of pathogen disinfection efficiency of electrochemical advanced oxidation to become a sustainable technology for water reuse. CHEMOSPHERE 2023; 313:137393. [PMID: 36442679 DOI: 10.1016/j.chemosphere.2022.137393] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/22/2022] [Revised: 11/04/2022] [Accepted: 11/24/2022] [Indexed: 06/16/2023]
Abstract
Water treatment and reuse is gaining acceptance as a strategy to fight against water contamination and scarcity, but it usually requires complex treatments to ensure safety. Consequently, the electrochemical advanced processes have emerged as an effective alternative for water remediation. The main objective here is to perform a systematic study that quantifies the efficiency of a laboratory-scale electrochemical system to inactivate bacteria, bacterial spores, protozoa, bacteriophages and viruses in synthetic water, as well as in urban wastewater once treated in a wetland for reuse in irrigation. A Ti|RuO2-based plate and Si|BDD thin-film were comparatively employed as the anode, which was combined with a stainless-steel cathode in an undivided cell operating at 12 V. Despite the low resulting current density (<15 mA/cm2), both anodes demonstrated the production of oxidants in wetland effluent water. The disinfection efficiency was high for the bacteriophage MS2 (T99 in less than 7.1 min) and bacteria (T99 in about 30 min as maximum), but limited for CBV5 and TuV, spores and amoebas (T99 in more than 300 min). MS2 presented a rapid exponential inactivation regardless of the anode and bacteria showed similar sigmoidal curves, whereas human viruses, spores and amoebas resulted in linear profiles. Due the different sensitivity of microorganisms, different models must be considered to predict their inactivation kinetics. On this basis, it can be concluded that evaluating the viral inactivation from inactivation profiles determined for bacteria or some bacteriophages may be misleading. Therefore, neither bacteria nor bacteriophages are suitable models for the disinfection of water containing enteric viruses. The electrochemical treatment added as a final disinfection step enhances the inactivation of microorganisms, which could contribute to safe water reuse for irrigation. Considering the calculated low energy consumption, decentralized water treatment units powered by photovoltaic modules might be a near reality.
Collapse
Affiliation(s)
- Eva Forés
- Laboratory of Viruses Contaminants of Water and Food, Departament de Genètica, Microbiologia i Estadística, Facultat de Biologia, Universitat de Barcelona (UB), Barcelona, Spain; Institut de Recerca de l'Aigua (IdRA), Universitat de Barcelona (UB), Barcelona, Spain
| | - Cristina Mejías-Molina
- Laboratory of Viruses Contaminants of Water and Food, Departament de Genètica, Microbiologia i Estadística, Facultat de Biologia, Universitat de Barcelona (UB), Barcelona, Spain; Institut de Recerca de l'Aigua (IdRA), Universitat de Barcelona (UB), Barcelona, Spain
| | - Arantxa Ramos
- Secció de Microbiologia, Virologia i Biotecnologia, Departament de Genètica, Microbiologia i Estadística, Universitat de Barcelona (UB), Barcelona, Spain
| | - Marta Itarte
- Laboratory of Viruses Contaminants of Water and Food, Departament de Genètica, Microbiologia i Estadística, Facultat de Biologia, Universitat de Barcelona (UB), Barcelona, Spain; Institut de Recerca de l'Aigua (IdRA), Universitat de Barcelona (UB), Barcelona, Spain
| | - Ayalkibet Hundesa
- Laboratory of Viruses Contaminants of Water and Food, Departament de Genètica, Microbiologia i Estadística, Facultat de Biologia, Universitat de Barcelona (UB), Barcelona, Spain; Institut de Recerca de l'Aigua (IdRA), Universitat de Barcelona (UB), Barcelona, Spain
| | - Marta Rusiñol
- Laboratory of Viruses Contaminants of Water and Food, Departament de Genètica, Microbiologia i Estadística, Facultat de Biologia, Universitat de Barcelona (UB), Barcelona, Spain; Institut de Recerca de l'Aigua (IdRA), Universitat de Barcelona (UB), Barcelona, Spain
| | - Sandra Martínez-Puchol
- Laboratory of Viruses Contaminants of Water and Food, Departament de Genètica, Microbiologia i Estadística, Facultat de Biologia, Universitat de Barcelona (UB), Barcelona, Spain; Institut de Recerca de l'Aigua (IdRA), Universitat de Barcelona (UB), Barcelona, Spain
| | - Pau Esteve-Bricullé
- Secció de Microbiologia, Virologia i Biotecnologia, Departament de Genètica, Microbiologia i Estadística, Universitat de Barcelona (UB), Barcelona, Spain
| | - Alejandro Espejo-Valverde
- Secció de Microbiologia, Virologia i Biotecnologia, Departament de Genètica, Microbiologia i Estadística, Universitat de Barcelona (UB), Barcelona, Spain
| | - Ignasi Sirés
- Laboratori d'Electroquímica dels Materials i del Medi Ambient, Departament de Ciència de Materials i Química Física, Secció de Química Física, Facultat de Química, Universitat de Barcelona, Martí i Franquès 1-11, 08028, Barcelona, Spain
| | - Miquel Calvo
- Secció d'Estadística, Departament de Genètica, Microbiologia i Estadística, Facultat de Biologia, Universitat de Barcelona (UB), Barcelona, Spain
| | - Rosa M Araujo
- Secció de Microbiologia, Virologia i Biotecnologia, Departament de Genètica, Microbiologia i Estadística, Universitat de Barcelona (UB), Barcelona, Spain
| | - Rosina Girones
- Laboratory of Viruses Contaminants of Water and Food, Departament de Genètica, Microbiologia i Estadística, Facultat de Biologia, Universitat de Barcelona (UB), Barcelona, Spain; Institut de Recerca de l'Aigua (IdRA), Universitat de Barcelona (UB), Barcelona, Spain.
| |
Collapse
|
17
|
Alhazmi A, Nekoua MP, Mercier A, Vergez I, Sane F, Alidjinou EK, Hober D. Combating coxsackievirus B infections. Rev Med Virol 2023; 33:e2406. [PMID: 36371612 DOI: 10.1002/rmv.2406] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2022] [Revised: 10/11/2022] [Accepted: 10/27/2022] [Indexed: 11/15/2022]
Abstract
Coxsackieviruses B (CVB) are small, non-enveloped, single-stranded RNA viruses belonging to the Enterovirus genus of the Picornaviridae family. They are common worldwide and cause a wide variety of human diseases ranging from those having relatively mild symptoms to severe acute and chronic pathologies such as cardiomyopathy and type 1 diabetes. The development of safe and effective strategies to combat these viruses remains a challenge. The present review outlines current approaches to control CVB infections and associated diseases. Various drugs targeting viral or host proteins involved in viral replication as well as vaccines have been developed and shown potential to prevent or combat CVB infections in vitro and in vivo in animal models. Repurposed drugs and alternative strategies targeting miRNAs or based on plant extracts and probiotics and their derivatives have also shown antiviral effects against CVB. In addition, clinical trials with vaccines and drugs are underway and offer hope for the prevention or treatment of CVB-induced diseases.
Collapse
Affiliation(s)
- Abdulaziz Alhazmi
- Laboratoire de Virologie ULR3610, Université de Lille et CHU de Lille, Lille, France.,Microbiology and Parasitology Department, Faculty of Medicine, Jazan University, Jazan, Saudi Arabia
| | | | - Ambroise Mercier
- Laboratoire de Virologie ULR3610, Université de Lille et CHU de Lille, Lille, France
| | - Ines Vergez
- Laboratoire de Virologie ULR3610, Université de Lille et CHU de Lille, Lille, France
| | - Famara Sane
- Laboratoire de Virologie ULR3610, Université de Lille et CHU de Lille, Lille, France
| | | | - Didier Hober
- Laboratoire de Virologie ULR3610, Université de Lille et CHU de Lille, Lille, France
| |
Collapse
|
18
|
Torii S, Corre MH, Miura F, Itamochi M, Haga K, Katayama K, Katayama H, Kohn T. Genotype-dependent kinetics of enterovirus inactivation by free chlorine and ultraviolet (UV) irradiation. WATER RESEARCH 2022; 220:118712. [PMID: 35691190 DOI: 10.1016/j.watres.2022.118712] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/03/2022] [Revised: 05/31/2022] [Accepted: 06/02/2022] [Indexed: 06/15/2023]
Abstract
Inactivation kinetics of enterovirus by disinfection is often studied using a single laboratory strain of a given genotype. Environmental variants of enterovirus are genetically distinct from the corresponding laboratory strain, yet it is poorly understood how these genetic differences affect inactivation. Here we evaluated the inactivation kinetics of nine coxsackievirus B3 (CVB3), ten coxsackievirus B4 (CVB4), and two echovirus 11 (E11) variants by free chlorine and ultraviolet irradiation (UV). The inactivation kinetics by free chlorine were genotype- (i.e., susceptibility: CVB5 < CVB3 ≈ CVB4 < E11) and genogroup-dependent and exhibited up to 15-fold difference among the tested viruses. In contrast, only minor (up to 1.3-fold) differences were observed in the UV inactivation kinetics. The differences in variability between the two disinfectants could be rationalized by their respective inactivation mechanisms: inactivation by UV mainly depends on the genomic size and composition, which was similar for all viruses tested, whereas free chlorine targets the viral capsid protein, which exhibited critical differences between genogroups and genotypes. Finally, we integrated the observed variability in inactivation rate constants into an expanded Chick-Watson model to estimate the overall inactivation of an enterovirus consortium. The results highlight that the distribution of inactivation rate constants and the abundance of each genotype are essential parameters to accurately predict the overall inactivation of an enterovirus population by free chlorine. We conclude that predictions based on inactivation data of a single variant or reference pathogen alone likely overestimate the true disinfection efficiency of free chlorine.
Collapse
Affiliation(s)
- Shotaro Torii
- Laboratory of Environmental Chemistry, School of Architecture, Civil and Environmental Engineering (ENAC), École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland; Department of Urban Engineering, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, Japan.
| | - Marie-Hélène Corre
- Laboratory of Environmental Chemistry, School of Architecture, Civil and Environmental Engineering (ENAC), École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
| | - Fuminari Miura
- Center for Marine Environmental Studies (CMES), Ehime University, Bunkyo-cho 3, Matsuyama-shi, Ehime, Japan; Centre for Infectious Disease Control, National Institute for Public Health and the Environment (RIVM), Bilthoven, the Netherlands
| | - Masae Itamochi
- Department of Virology, Toyama Institute of Health, 17-1 Nakataikoyama, Imizu-shi, Toyama, Japan
| | - Kei Haga
- Laboratory of Viral Infection, Department of Infection Control and Immunology, Ōmura Satoshi Memorial Institute & Graduate School of Infection Control Sciences, Kitasato University, Tokyo 108-8641, Japan
| | - Kazuhiko Katayama
- Laboratory of Viral Infection, Department of Infection Control and Immunology, Ōmura Satoshi Memorial Institute & Graduate School of Infection Control Sciences, Kitasato University, Tokyo 108-8641, Japan
| | - Hiroyuki Katayama
- Department of Urban Engineering, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, Japan
| | - Tamar Kohn
- Laboratory of Environmental Chemistry, School of Architecture, Civil and Environmental Engineering (ENAC), École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
| |
Collapse
|
19
|
Oishi W, Sato M, Kubota K, Ishiyama R, Takai-Todaka R, Haga K, Katayama K, Sano D. Experimental Adaptation of Murine Norovirus to Calcium Hydroxide. Front Microbiol 2022; 13:848439. [PMID: 35432235 PMCID: PMC9009222 DOI: 10.3389/fmicb.2022.848439] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2022] [Accepted: 02/21/2022] [Indexed: 11/18/2022] Open
Abstract
Slaked lime (calcium hydroxide) is a commonly used disinfectant for fecal sludge. Although viruses are inactivated by lime treatment, whether RNA viruses adapt to lime treatment has not yet been determined. Here, we show that murine norovirus developed higher tolerance during serial passages with lime treatment. We compared synonymous and non-synonymous nucleotide diversities of the three open reading frames of viral genome and revealed that virus populations were subjected to enhanced purifying selection over the course of serial passages with lime treatment. Virus adaptation to lime treatment was coincident with amino acid substitution of lysine to arginine at position 345 (K345R) on the major capsid protein VP1, which accounted for more than 90% of the population. The infectious clones with the K345R produced using a plasmid-based reverse genetics system exhibited greater tolerance in a lime solution, which indicated that the specific amino acid substitution was solely involved in the viral tolerance in lime treatment.
Collapse
Affiliation(s)
- Wakana Oishi
- Department of Civil and Environmental Engineering, Graduate School of Engineering, Tohoku University, Sendai, Japan
| | - Mikiko Sato
- Department of Frontier Sciences for Advanced Environment, Graduate School of Environmental Studies, Tohoku University, Sendai, Japan
| | - Kengo Kubota
- Department of Civil and Environmental Engineering, Graduate School of Engineering, Tohoku University, Sendai, Japan
- Department of Frontier Sciences for Advanced Environment, Graduate School of Environmental Studies, Tohoku University, Sendai, Japan
| | - Ryoka Ishiyama
- Laboratory of Viral Infection I, Department of Infection Control and Immunology, Ōmura Satoshi Memorial Institute & Graduate School of Infection Control Sciences, Kitasato University, Tokyo, Japan
| | - Reiko Takai-Todaka
- Laboratory of Viral Infection I, Department of Infection Control and Immunology, Ōmura Satoshi Memorial Institute & Graduate School of Infection Control Sciences, Kitasato University, Tokyo, Japan
| | - Kei Haga
- Laboratory of Viral Infection I, Department of Infection Control and Immunology, Ōmura Satoshi Memorial Institute & Graduate School of Infection Control Sciences, Kitasato University, Tokyo, Japan
| | - Kazuhiko Katayama
- Laboratory of Viral Infection I, Department of Infection Control and Immunology, Ōmura Satoshi Memorial Institute & Graduate School of Infection Control Sciences, Kitasato University, Tokyo, Japan
| | - Daisuke Sano
- Department of Civil and Environmental Engineering, Graduate School of Engineering, Tohoku University, Sendai, Japan
- Department of Frontier Sciences for Advanced Environment, Graduate School of Environmental Studies, Tohoku University, Sendai, Japan
- Research Institute for Humanity and Nature, Kyoto, Japan
- *Correspondence: Daisuke Sano,
| |
Collapse
|
20
|
Zhang M, Guo W, Xu D, Feng C, Bao G, Sun H, Yang Z, Ma S. Molecular characterization of echovirus 9 strains isolated from hand-foot-and-mouth disease in Kunming, Yunnan Province, China. Sci Rep 2022; 12:2293. [PMID: 35145190 PMCID: PMC8831506 DOI: 10.1038/s41598-022-06309-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2021] [Accepted: 01/24/2022] [Indexed: 11/09/2022] Open
Abstract
Echovirus 9 (E9) belongs to the species Enterovirus B. So far, 12 whole genome sequences of E9 are available in GenBank. In this study, we determined the whole genomic sequences of five E9 strains isolated from the stools of patients with hand-foot-and-mouth disease in Kunming, Yunnan Province, China, in 2019. Their nucleotide and amino acid sequences shared 80.8–80.9% and 96.4–96.8% identity with the prototype Hill strain, respectively, and shared 99.3–99.9% and 99.1–99.8% mutual identity, respectively. Recombination analyses revealed that intertype recombination had occurred in the 2C and 3D regions of the five Yunnan E9 strains with coxsackieviruses B5 and B4, respectively. This study augmented the whole genome sequences of E9 in the GenBank database and extended the molecular characterization of this virus in China.
Collapse
Affiliation(s)
- Ming Zhang
- Institute of Medical Biology, Peking Union Medical College, Chinese Academy of Medical Sciences, Kunming, 650118, People's Republic of China.,Yunnan Key Laboratory of Vaccine Research Development on Severe Infectious Disease, Kunming, 650118, People's Republic of China
| | - Wei Guo
- Institute of Medical Biology, Peking Union Medical College, Chinese Academy of Medical Sciences, Kunming, 650118, People's Republic of China.,Yunnan Key Laboratory of Vaccine Research Development on Severe Infectious Disease, Kunming, 650118, People's Republic of China
| | - Danhan Xu
- Institute of Medical Biology, Peking Union Medical College, Chinese Academy of Medical Sciences, Kunming, 650118, People's Republic of China.,Yunnan Key Laboratory of Vaccine Research Development on Severe Infectious Disease, Kunming, 650118, People's Republic of China
| | - Changzeng Feng
- Institute of Medical Biology, Peking Union Medical College, Chinese Academy of Medical Sciences, Kunming, 650118, People's Republic of China.,Yunnan Key Laboratory of Vaccine Research Development on Severe Infectious Disease, Kunming, 650118, People's Republic of China
| | - Guohong Bao
- First People's Hospital of Yunnan Province, Kunming, People's Republic of China
| | - Hao Sun
- Institute of Medical Biology, Peking Union Medical College, Chinese Academy of Medical Sciences, Kunming, 650118, People's Republic of China.,Yunnan Key Laboratory of Vaccine Research Development on Severe Infectious Disease, Kunming, 650118, People's Republic of China
| | - Zhaoqing Yang
- Institute of Medical Biology, Peking Union Medical College, Chinese Academy of Medical Sciences, Kunming, 650118, People's Republic of China.,Yunnan Key Laboratory of Vaccine Research Development on Severe Infectious Disease, Kunming, 650118, People's Republic of China
| | - Shaohui Ma
- Institute of Medical Biology, Peking Union Medical College, Chinese Academy of Medical Sciences, Kunming, 650118, People's Republic of China. .,Yunnan Key Laboratory of Vaccine Research Development on Severe Infectious Disease, Kunming, 650118, People's Republic of China.
| |
Collapse
|
21
|
Qiao Z, Ye Y, Szczuka A, Harrison KR, Dodd MC, Wigginton KR. Reactivity of Viral Nucleic Acids with Chlorine and the Impact of Virus Encapsidation. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2022; 56:218-227. [PMID: 34905340 DOI: 10.1021/acs.est.1c04239] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Free chlorine disinfection is widely applied to inactivate viruses by reacting with their biomolecules, which include nucleic acids, proteins, and lipids. Knowing the reactivities of viral genomes with free chlorine and the protection that encapsidation provides would ultimately help predict virus susceptibility to the disinfectant. The relative reactivities of different viral genome types and the impact of viral higher order structure with free chlorine are poorly characterized. Here, we studied the reactivity of viral genomes representing four genome types from virus particles with diverse structures, namely, (+)ssRNA (MS2), dsRNA (φ6), ssDNA (φX174), and dsDNA (T3) with free chlorine. We compared the reactivities of these viral nucleic acids when they were suspended in phosphate buffer solutions (naked forms) and when they were in the native virus particles (encapsidated forms). The reactivities of nucleic acids were tracked by polymerase chain reaction (PCR)-based assays. The naked dsDNA of T3 was the least reactive with free chlorine, with an average second order rate constant normalized by the number of bases in the measured regions (in M-1 s-1 b-1) that was 34×, 65×, and 189× lower than those of the dsRNA of φ6, ssRNA of MS2, and ssDNA of φX174, respectively. Moreover, different regions in the ssRNA genome of MS2 and the dsRNA genome of φ6 exhibited statistically different reaction kinetics. The genomes within virus particles reacted slower than the naked genomes overall, but the extent of these differences varied among the four viruses. The results on viral nucleic acid reactivity help explain different susceptibilities of viruses to inactivation by free chlorine and also provide a valuable comparison of the susceptibilities of different nucleic acids to oxidants.
Collapse
Affiliation(s)
- Zhong Qiao
- Department of Civil and Environmental Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Yinyin Ye
- Department of Civil and Environmental Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
- Department of Civil, Structural, and Environmental Engineering, University at Buffalo, Buffalo, New York 14260, United States
| | - Aleksandra Szczuka
- Department of Civil and Environmental Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Katherine R Harrison
- Department of Civil and Environmental Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Michael C Dodd
- Department of Civil and Environmental Engineering, University of Washington, Seattle, Washington 98195, United States
| | - Krista R Wigginton
- Department of Civil and Environmental Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
| |
Collapse
|
22
|
Chen C, Guo L, Yang Y, Oguma K, Hou LA. Comparative effectiveness of membrane technologies and disinfection methods for virus elimination in water: A review. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 801:149678. [PMID: 34416607 PMCID: PMC8364419 DOI: 10.1016/j.scitotenv.2021.149678] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/12/2021] [Revised: 07/20/2021] [Accepted: 08/11/2021] [Indexed: 05/22/2023]
Abstract
The pandemic of the 2019 novel coronavirus disease (COVID-19) has brought viruses into the public horizon. Since viruses can pose a threat to human health in a low concentration range, seeking efficient virus removal methods has been the research hotspots in the past few years. Herein, a total of 1060 research papers were collected from the Web of Science database to identify technological trends as well as the research status. Based on the analysis results, this review elaborates on the state-of-the-art of membrane filtration and disinfection technologies for the treatment of virus-containing wastewater and drinking water. The results evince that membrane and disinfection methods achieve a broad range of virus removal efficiency (0.5-7 log reduction values (LRVs) and 0.09-8 LRVs, respectively) that is attributable to the various interactions between membranes or disinfectants and viruses having different susceptibility in viral capsid protein and nucleic acid. Moreover, this review discusses the related challenges and potential of membrane and disinfection technologies for customized virus removal in order to prevent the dissemination of the waterborne diseases.
Collapse
Affiliation(s)
- Chao Chen
- State Key Laboratory of Water Environment Simulation, School of Environment, Beijing Normal University, No.19, Xinjiekouwai Street, Haidian District, Beijing 100875, China.
| | - Lihui Guo
- State Key Laboratory of Water Environment Simulation, School of Environment, Beijing Normal University, No.19, Xinjiekouwai Street, Haidian District, Beijing 100875, China.
| | - Yu Yang
- State Key Laboratory of Water Environment Simulation, School of Environment, Beijing Normal University, No.19, Xinjiekouwai Street, Haidian District, Beijing 100875, China.
| | - Kumiko Oguma
- Department of Urban Engineering, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan.
| | - Li-An Hou
- State Key Laboratory of Water Environment Simulation, School of Environment, Beijing Normal University, No.19, Xinjiekouwai Street, Haidian District, Beijing 100875, China; Xi'an High-Tech Institute, Xi'an 710025, China.
| |
Collapse
|
23
|
Canh VD, Torii S, Yasui M, Kyuwa S, Katayama H. Capsid integrity RT-qPCR for the selective detection of intact SARS-CoV-2 in wastewater. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 791:148342. [PMID: 34139497 PMCID: PMC8184355 DOI: 10.1016/j.scitotenv.2021.148342] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/07/2021] [Revised: 06/04/2021] [Accepted: 06/05/2021] [Indexed: 05/05/2023]
Abstract
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) genomes have been detected in wastewater worldwide. However, the assessment of SARS-CoV-2 infectivity in wastewater has been limited due to the stringent requirements of biosafety level 3. The main objective of this study is to investigate the applicability of capsid integrity RT-qPCR for the selective detection of intact SARS-CoV-2 in wastewater. Three capsid integrity reagents, namely ethidium monoazide (EMA, 0.1-100 μM), propidium monoazide (PMA, 0.1-100 μM), and cis-dichlorodiammineplatinum (CDDP, 0.1-1000 μM), were tested for their effects on different forms (including free genomes, intact and heat-inactivated) of murine hepatitis virus (MHV), which was used as a surrogate for SARS-CoV-2. CDDP at a concentration of 100 μM was identified as the most efficient reagent for the selective detection of infectious MHV by RT-qPCR (CDDP-RT-qPCR). Next, two common virus concentration methods including ultrafiltration (UF) and polyethylene glycol (PEG) precipitation were investigated for their compatibility with capsid integrity RT-qPCR. The UF method was more suitable than the PEG method since it recovered intact MHV (mean ± SD, 38% ± 29%) in wastewater much better than the PEG method did (0.013% ± 0.015%). Finally, CDDP-RT-qPCR was compared with RT-qPCR alone for the detection of SARS-CoV-2 in 16 raw wastewater samples collected in the Greater Tokyo Area. Five samples were positive for SARS-CoV-2 when evaluated by RT-qPCR alone. However, intact SARS-CoV-2 was detected in only three positive samples when determined by CDDP-RT-qPCR. Although CDDP-RT-qPCR was unable to determine the infectivity of SARS-CoV-2 in wastewater, this method could improve the interpretation of positive results of SARS-CoV-2 obtained by RT-qPCR.
Collapse
Affiliation(s)
- Vu Duc Canh
- Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan.
| | - Shotaro Torii
- Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
| | - Midori Yasui
- Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
| | - Shigeru Kyuwa
- Graduate School of Agricultural and Life Sciences, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8657, Japan
| | - Hiroyuki Katayama
- Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan.
| |
Collapse
|
24
|
Bayarri B, Cruz-Alcalde A, López-Vinent N, Micó MM, Sans C. Can ozone inactivate SARS-CoV-2? A review of mechanisms and performance on viruses. JOURNAL OF HAZARDOUS MATERIALS 2021; 415:125658. [PMID: 33752085 PMCID: PMC7955572 DOI: 10.1016/j.jhazmat.2021.125658] [Citation(s) in RCA: 54] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Revised: 03/09/2021] [Accepted: 03/11/2021] [Indexed: 05/11/2023]
Abstract
Severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) pandemic has challenged societies around the globe. Technologies based on ozone, a powerful oxidant, have been evaluated to inactivate this virus in aerosols and fomites. However, the high data diversity hinders the possibility of establishing a common ground for determining best practices for the use of these technologies. Furthermore, there is a lack of consensus regarding which are the main mechanisms of ozone virus inactivation. This critical review examined the most relevant information available regarding ozone application in gas-phase for different viruses inactivation (including recent publications dealing with SARS-CoV-2), and pointed towards envelope alteration as the main reaction pathway for enveloped viruses, such as is the case of SARS-CoV-2. It could also be concluded that gaseous ozone can be indeed an effective disinfectant, successfully inactivating viruses such us influenza A H1N1, MERS-CoV, SARS-CoV-1 or even SARS-CoV-2 in aerosols or fomites. In reviewed works, low ozone exposures, just around 0.1-0.4 mg L-1 min, achieve about 4 log10 of inactivation in aerosols, while exposures between 1 and 4 mg L-1 min may be needed to guarantee an inactivation of 3-4 log10 in different fomites. Although further studies are required, ozone is an effective candidate to be used against SARS-CoV-2 or other viruses in surfaces and indoor locations.
Collapse
Affiliation(s)
- Bernardí Bayarri
- Department of Chemical Engineering and Analytical Chemistry, Faculty of Chemistry, Universitat de Barcelona, C/Martí i Franqués 1, 08028 Barcelona, Spain.
| | - Alberto Cruz-Alcalde
- Department of Chemical Engineering and Analytical Chemistry, Faculty of Chemistry, Universitat de Barcelona, C/Martí i Franqués 1, 08028 Barcelona, Spain
| | - Núria López-Vinent
- Department of Chemical Engineering and Analytical Chemistry, Faculty of Chemistry, Universitat de Barcelona, C/Martí i Franqués 1, 08028 Barcelona, Spain
| | - María M Micó
- Department of Chemical Engineering and Analytical Chemistry, Faculty of Chemistry, Universitat de Barcelona, C/Martí i Franqués 1, 08028 Barcelona, Spain
| | - Carme Sans
- Department of Chemical Engineering and Analytical Chemistry, Faculty of Chemistry, Universitat de Barcelona, C/Martí i Franqués 1, 08028 Barcelona, Spain
| |
Collapse
|
25
|
Larivé O, Brandani J, Dubey M, Kohn T. An integrated cell culture reverse transcriptase quantitative PCR (ICC-RTqPCR) method to simultaneously quantify the infectious concentrations of eight environmentally relevant enterovirus serotypes. J Virol Methods 2021; 296:114225. [PMID: 34216645 DOI: 10.1016/j.jviromet.2021.114225] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2021] [Revised: 06/28/2021] [Accepted: 06/28/2021] [Indexed: 11/27/2022]
Abstract
Enterovirus (EV) infectivity is typically measured as a bulk parameter, yet EV serotypes vary in their susceptibility to natural and engineered stressors. Here we developed an integrated cell culture reverse transcriptase quantitative PCR (ICC-RTqPCR) method to simultaneously and specifically quantify the infectious concentrations of eight EV serotypes commonly encountered in sewage (coxsackieviruses A9, B1, B2, B3, B4 and B5, and echoviruses 25 and 30). The method uses two cell lines for virus replication and serotype-specific qPCR primers for quantification. Primers were designed to target multiple environmental strains of a given serotype and displayed high specificity. The ICC-RTqPCR method exhibited a linear calibration range between 50 and 1000 (echoviruses) or 5000 (coxsackieviruses) infectious units per mL. Over this range, measurements were not influenced by the presence of non-target serotypes, and calibration slopes were reproducible for different virus batches and cell ages. The ICC-RTqPCR method was able to accurately quantify the infectious concentration of a virus after inactivation by heat, and the concentration of a virus within a wastewater matrix. This method will be valuable to assess the differing fates of EV serotypes in natural or engineered systems, and to portray the associated changes in EV population composition.
Collapse
Affiliation(s)
- Odile Larivé
- Laboratory of Environmental Chemistry, School of Architecture, Civil and Environmental Engineering, École Polytechnique Fédérale de Lausanne (EPFL), CH-1015, Lausanne, Switzerland
| | - Jade Brandani
- Laboratory of Environmental Chemistry, School of Architecture, Civil and Environmental Engineering, École Polytechnique Fédérale de Lausanne (EPFL), CH-1015, Lausanne, Switzerland
| | - Manupriyam Dubey
- Laboratory of Environmental Chemistry, School of Architecture, Civil and Environmental Engineering, École Polytechnique Fédérale de Lausanne (EPFL), CH-1015, Lausanne, Switzerland
| | - Tamar Kohn
- Laboratory of Environmental Chemistry, School of Architecture, Civil and Environmental Engineering, École Polytechnique Fédérale de Lausanne (EPFL), CH-1015, Lausanne, Switzerland.
| |
Collapse
|
26
|
Kumar M, Mazumder P, Mohapatra S, Kumar Thakur A, Dhangar K, Taki K, Mukherjee S, Kumar Patel A, Bhattacharya P, Mohapatra P, Rinklebe J, Kitajima M, Hai FI, Khursheed A, Furumai H, Sonne C, Kuroda K. A chronicle of SARS-CoV-2: Seasonality, environmental fate, transport, inactivation, and antiviral drug resistance. JOURNAL OF HAZARDOUS MATERIALS 2021; 405:124043. [PMID: 33268203 PMCID: PMC7536132 DOI: 10.1016/j.jhazmat.2020.124043] [Citation(s) in RCA: 56] [Impact Index Per Article: 18.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/22/2020] [Revised: 09/11/2020] [Accepted: 09/17/2020] [Indexed: 05/08/2023]
Abstract
In this review, we present the environmental perspectives of the viruses and antiviral drugs related to SARS-CoV-2. The present review paper discusses occurrence, fate, transport, susceptibility, and inactivation mechanisms of viruses in the environment as well as environmental occurrence and fate of antiviral drugs, and prospects (prevalence and occurrence) of antiviral drug resistance (both antiviral drug resistant viruses and antiviral resistance in the human). During winter, the number of viral disease cases and environmental occurrence of antiviral drug surge due to various biotic and abiotic factors such as transmission pathways, human behaviour, susceptibility, and immunity as well as cold climatic conditions. Adsorption and persistence critically determine the fate and transport of viruses in the environment. Inactivation and disinfection of virus include UV, alcohol, and other chemical-base methods but the susceptibility of virus against these methods varies. Wastewater treatment plants (WWTPs) are major reserviors of antiviral drugs and their metabolites and transformation products. Ecotoxicity of antiviral drug residues against aquatic organisms have been reported, however more threatening is the development of antiviral resistance, both in humans and in wild animal reservoirs. In particular, emergence of antiviral drug-resistant viruses via exposure of wild animals to high loads of antiviral residues during the current pandemic needs further evaluation.
Collapse
Affiliation(s)
- Manish Kumar
- Discipline of Earth Science, Indian Institute of Technology Gandhinagar, Gujarat 382 355, India.
| | - Payal Mazumder
- Centre for the Environment, Indian Institute of Technology Guwahati, Guwahati 781039, Assam, India
| | - Sanjeeb Mohapatra
- Environmnetal Science and Engineering Department, Indian Institute of Technology Bombay, Mumbai 400076, India
| | - Alok Kumar Thakur
- Discipline of Earth Science, Indian Institute of Technology Gandhinagar, Gujarat 382 355, India
| | - Kiran Dhangar
- Discipline of Earth Science, Indian Institute of Technology Gandhinagar, Gujarat 382 355, India
| | - Kaling Taki
- Discipline of Civil Engineering, Indian Institute of Technology Gandhinagar, Gujarat 382 355, India
| | - Santanu Mukherjee
- Discipline of Earth Science, Indian Institute of Technology Gandhinagar, Gujarat 382 355, India
| | - Arbind Kumar Patel
- Discipline of Earth Science, Indian Institute of Technology Gandhinagar, Gujarat 382 355, India
| | - Prosun Bhattacharya
- Department of Sustainable Development, Environmental Science and Engineering, KTH Royal Institute of Technology, Teknikringen 10B, SE-10044 Stockholm, Sweden
| | - Pranab Mohapatra
- Discipline of Civil Engineering, Indian Institute of Technology Gandhinagar, Gujarat 382 355, India
| | - Jörg Rinklebe
- Laboratory of Soil- and Groundwater-Management, School of Architecture and Civil Engineering, University of Wuppertal, Wuppertal 42285, Germany; Department of Environment, Energy and Geoinformatics, University of Sejong, Seoul, South Korea
| | - Masaaki Kitajima
- Division of Environmental Engineering, Hokkaido University, Hokkaido 060-8628, Japan
| | - Faisal I Hai
- Wollongong, Strategic Water Infrastructure Laboratory, School of Civil, Mining and Environmental Engineering, University of Wollongong, NSW 2522, Australia
| | - Anwar Khursheed
- Department of Civil Engineering, King Saud University, Riyadh, Saudi Arabia
| | - Hiroaki Furumai
- Research Centre for Water Environment Technology, Graduate School of Engineering, The University of Tokyo, Tokyo 113-8656, Japan
| | - Christian Sonne
- Department of Bioscience, Aarhus University, Frederiksborgvej 399, PO Box 358, DK-4000 Roskilde, Denmark
| | - Keisuke Kuroda
- Department of Environmental and Civil Engineering, Toyama Prefectural University, Toyama 9390398, Japan
| |
Collapse
|
27
|
Torii S, Miura F, Itamochi M, Haga K, Katayama K, Katayama H. Impact of the Heterogeneity in Free Chlorine, UV 254, and Ozone Susceptibilities Among Coxsackievirus B5 on the Prediction of the Overall Inactivation Efficiency. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2021; 55:3156-3164. [PMID: 33583178 DOI: 10.1021/acs.est.0c07796] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
The disinfection susceptibilities of viruses vary even among variants, yet the inactivation efficiency of a certain virus genotype, species, or genus was determined based on the susceptibility of its laboratory strain. The objectives were to evaluate the variability in susceptibilities to free chlorine, UV254, and ozone among 13 variants of coxsackievirus B5 (CVB5) and develop the model allowing for predicting the overall inactivation of heterogeneous CVB5. Our results showed that the susceptibilities differed by up to 3.4-fold, 1.3-fold, and 1.8-fold in free chlorine, UV254, and ozone, respectively. CVB5 in genogroup B exhibited significantly lower susceptibility to free chlorine and ozone than genogroup A, where the laboratory strain, Faulkner, belongs. The capsid protein in genogroup B contained a lower number of sulfur-containing amino acids, readily reactive to oxidants. We reformulated the Chick-Watson model by incorporating the probability distributions of inactivation rate constants to capture the heterogeneity. This expanded Chick-Watson model indicated that up to 4.2-fold larger free chlorine CT is required to achieve 6-log inactivation of CVB5 than the prediction by the Faulkner strain. Therefore, it is recommended to incorporate the variation in disinfection susceptibilities for predicting the overall inactivation of a certain type of viruses.
Collapse
Affiliation(s)
- Shotaro Torii
- Department of Urban Engineering, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8654, Japan
| | - Fuminari Miura
- Center for Marine Environmental Studies (CMES), Ehime University, Bunkyo-cho 3, Matsuyama-shi, Ehime 790-8577, Japan
| | - Masae Itamochi
- Department of Virology, Toyama Institute of Health, 17-1 Nakataikoyama, Imizu-shi, Toyama 939-0363, Japan
| | - Kei Haga
- Laboratory of Viral Infection I, Department of Infection Control and Immunology, O̅mura Satoshi Memorial Institute & Graduate School of Infection Control Sciences, Kitasato University, Tokyo 108-8641, Japan
| | - Kazuhiko Katayama
- Laboratory of Viral Infection I, Department of Infection Control and Immunology, O̅mura Satoshi Memorial Institute & Graduate School of Infection Control Sciences, Kitasato University, Tokyo 108-8641, Japan
| | - Hiroyuki Katayama
- Department of Urban Engineering, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8654, Japan
| |
Collapse
|
28
|
Torii S, Itamochi M, Katayama H. Inactivation kinetics of waterborne virus by ozone determined by a continuous quench flow system. WATER RESEARCH 2020; 186:116291. [PMID: 32836147 DOI: 10.1016/j.watres.2020.116291] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/11/2020] [Revised: 08/07/2020] [Accepted: 08/09/2020] [Indexed: 05/22/2023]
Abstract
Ozone has a strong oxidation power that allows effective inactivation of waterborne viruses. Few studies have accurately measured the kinetic relationship between virus inactivation and ozone exposure, because the high reactivity of ozone makes it difficult to measure them simultaneously. A continuous quench flow system (CQFS) is a possible solution for analyzing such a fast reaction; however, previous studies reported that CQFS provided different results of inactivation rate constants from the batch system. The objectives of this study were (1) to develop a CQFS to evaluate the kinetics of microbial inactivation accurately, (2) to evaluate the inactivation rate constants of waterborne virus by ozone, and (3) to compare the results with previous studies. The results indicated that the simple plug flow assumption in the reaction tube of CQFS led to underestimation of the rate constants. The accurate measurement of rate constants was achieved by the pseudo-first-order reaction model that takes the residence time distribution (RTD; i.e., the laminar flow assumption) into account. The results of inactivation experiments suggested that the resistance of viruses were getting higher in the following order: Qβ < MS2, fr, GA < CVB5 Faulkner, φX-174, PV1 Sabin, CVB3 Nancy. The environmental isolates of CVB3 and CVB5 had a 2-fold higher resistance compared with their lab strains. Predicted CT values for 4-log inactivation ranged from 0.018 mg sec L-1 (Qβ) to 0.31 mg sec L-1 (CVB3 Environmental strain). The required CT values for 4-log PV1 inactivation was 0.15 mg sec L-1, which was 166-fold smaller than those reported in the United States Environmental Protection Agency guidance manuals. The overestimation in previous studies was due to the sparse assumption of RTD in the reactor. Consequently, the required ozone CT values for virus inactivation should be reconsidered to minimize the health risks and environmental costs in water treatment.
Collapse
Affiliation(s)
- Shotaro Torii
- Department of Urban Engineering, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, Japan.
| | - Masae Itamochi
- Department of Virology, Toyama Institute of Health, 17-1 Nakataikoyama, Imizu-shi, Toyama, Japan
| | - Hiroyuki Katayama
- Department of Urban Engineering, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, Japan
| |
Collapse
|
29
|
Shirasaki N, Matsushita T, Matsui Y, Koriki S. Suitability of pepper mild mottle virus as a human enteric virus surrogate for assessing the efficacy of thermal or free-chlorine disinfection processes by using infectivity assays and enhanced viability PCR. WATER RESEARCH 2020; 186:116409. [PMID: 32942179 DOI: 10.1016/j.watres.2020.116409] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/22/2020] [Revised: 09/02/2020] [Accepted: 09/06/2020] [Indexed: 05/05/2023]
Abstract
Evaluating the efficacy of disinfection processes to inactivate human enteric viruses is important for the prevention and control of waterborne diseases caused by exposure to those viruses via drinking water. Here, we evaluated the inactivation of two representative human enteric viruses (adenovirus type 40 [AdV] and coxsackievirus B5 [CV]) by thermal or free-chlorine disinfection. In addition, we compared the infectivity reduction ratio of a plant virus (pepper mild mottle virus [PMMoV], a recently proposed novel surrogate for human enteric viruses for the assessment of virus removal by coagulation‒rapid sand filtration and membrane filtration) with that of the two human enteric viruses to assess the suitability of PMMoV as a human enteric virus surrogate for use in thermal and free-chlorine disinfection processes. Finally, we examined whether conventional or enhanced viability polymerase chain reaction (PCR) analysis using propidium monoazide (PMA) or improved PMA (PMAxx) with or without an enhancer could be used as alternatives to infectivity assays (i.e., plaque-forming unit method for AdV and CV; local lesion count assay for PMMoV) for evaluating virus inactivation by disinfection processes. We found that PMMoV was more resistant to heat treatment than AdV and CV, suggesting that PMMoV is a potential surrogate for these two enteric viruses with regard to thermal disinfection processes. However, PMMoV was much more resistant to chlorine treatment compared with AdV and CV (which is chlorine-resistant) (CT value for 4-log10 inactivation: PMMoV, 84.5 mg-Cl2·min/L; CV, 1.15-1.19 mg-Cl2·min/L), suggesting that PMMoV is not useful as a surrogate for these enteric viruses with regard to free-chlorine disinfection processes. For thermal disinfection, the magnitude of the signal reduction observed with PMAxx-Enhancer-PCR was comparable with the magnitude of reduction in infectivity, indicating that PMAxx-Enhancer-PCR is a potential alternative to infectivity assay. However, for free-chlorine disinfection, the magnitude of the signal reduction observed with PMAxx-Enhancer-PCR was smaller than the magnitude of the reduction in infectivity, indicating that PMAxx-Enhancer-PCR underestimated the efficacy of virus inactivation (i.e., overestimated the infectious virus concentration) by chlorine treatment. Nevertheless, among the PCR approaches examined in the present study (PCR alone, PMA-PCR or PMAxx-PCR either with or without enhancer), PMAxx-Enhancer-PCR provided the most accurate assessment of the efficacy of virus inactivation by thermal or free chlorine disinfection processes.
Collapse
Affiliation(s)
- N Shirasaki
- Division of Environmental Engineering, Faculty of Engineering, Hokkaido University, N13W8, Sapporo, 060-8628, Japan.
| | - T Matsushita
- Division of Environmental Engineering, Faculty of Engineering, Hokkaido University, N13W8, Sapporo, 060-8628, Japan
| | - Y Matsui
- Division of Environmental Engineering, Faculty of Engineering, Hokkaido University, N13W8, Sapporo, 060-8628, Japan
| | - S Koriki
- Division of Environmental Engineering, Faculty of Engineering, Hokkaido University, N13W8, Sapporo, 060-8628, Japan
| |
Collapse
|
30
|
Carratalà A, Bachmann V, Julian TR, Kohn T. Adaptation of Human Enterovirus to Warm Environments Leads to Resistance against Chlorine Disinfection. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2020; 54:11292-11300. [PMID: 32875801 DOI: 10.1021/acs.est.0c03199] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Sunlight, temperature, and microbial grazing are among the environmental factors promoting the inactivation of viral pathogens in surface waters. Globally, these factors vary across time and space. The persistence of viral pathogens, and ultimately their ecology and dispersion, hinges on their ability to withstand the environmental conditions encountered. To understand how virus populations evolve under changing environmental conditions, we experimentally adapted echovirus 11 (E11) to four climate regimes. Specifically, we incubated E11 in lake water at 10 and 30 °C and in the presence and absence of sunlight. Temperature was the main driver of adaptation, resulting in an increased thermotolerance of the 30 °C adapted populations, whereas the 10 °C adapted strains were rapidly inactivated at higher temperatures. This finding is consistent with a source-sink model in which strains emerging in warm climates can persist in temperate regions, but not vice versa. A microbial risk assessment revealed that the enhanced thermotolerance increases the length of time in which there is an elevated probability of illness associated with swimming in contaminated water. Notably, 30 °C-adapted viruses also exhibited an increased tolerance toward disinfection by free chlorine. Viruses adapting to warm environments may thus become harder to eliminate by common disinfection strategies.
Collapse
Affiliation(s)
- Anna Carratalà
- Laboratory of Environmental Chemistry, School of Architecture, Civil and Environmental Engineering (ENAC), École Polytechnique Fédérale de Lausanne (EPFL), CH-1015 Lausanne, Switzerland
| | - Virginie Bachmann
- Laboratory of Environmental Chemistry, School of Architecture, Civil and Environmental Engineering (ENAC), École Polytechnique Fédérale de Lausanne (EPFL), CH-1015 Lausanne, Switzerland
| | - Timothy R Julian
- Eawag, Swiss Federal Institute of Aquatic Science and Technology, Dübendorf8600, Switzerland
- Swiss Tropical and Public Health Institute, Basel 4051, Switzerland
- University of Basel, Basel 4051, Switzerland
| | - Tamar Kohn
- Laboratory of Environmental Chemistry, School of Architecture, Civil and Environmental Engineering (ENAC), École Polytechnique Fédérale de Lausanne (EPFL), CH-1015 Lausanne, Switzerland
| |
Collapse
|
31
|
Espinosa MF, Sancho AN, Mendoza LM, Mota CR, Verbyla ME. Systematic review and meta-analysis of time-temperature pathogen inactivation. Int J Hyg Environ Health 2020; 230:113595. [DOI: 10.1016/j.ijheh.2020.113595] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2020] [Revised: 06/04/2020] [Accepted: 07/06/2020] [Indexed: 11/16/2022]
|
32
|
Xu L, Graham NJD, Wei C, Zhang L, Yu W. Abatement of the membrane biofouling: Performance of an in-situ integrated bioelectrochemical-ultrafiltration system. WATER RESEARCH 2020; 179:115892. [PMID: 32388047 DOI: 10.1016/j.watres.2020.115892] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/08/2020] [Revised: 04/22/2020] [Accepted: 04/25/2020] [Indexed: 06/11/2023]
Abstract
The practical applications of membrane-based water treatment techniques are constrained by the problem of membrane fouling. Various studies have revealed that interactions between extracellular polymeric substances (EPS) and the membrane surface determine the extent of irreversible fouling. Herein, we describe a novel bioelectrochemical system (BES) integrated with an ultrafiltration (UF) membrane in order to provide an enhanced antifouling property. It was found that the integrated BES membrane system had a superior performance compared to a conventional (control) UF system, as manifested by a much lower development of transmembrane pressure. The BES significantly reduced microbial viability in the membrane tank and the imposed electrode potential contributed to the degradation of biopolymers, which favored the alleviation of membrane fouling. Notably, the electron transfer between the acclimated microorganisms and the conductive membrane in the BES integrated system exhibited an increasing trend with the operation time, indicating a gradual increase in microbial electrical activity. Correspondingly, the accumulation of extracellular polymeric substances (EPS) on the membrane surface of the BES integrated system showed a substantial decrease compared to the control system, which could be attributed to a series of synergistic effects induced by the BES integration. The differences in the microbial diversity between the control and the BES integrated system revealed the microbial selectivity of the poised potential. Specifically, microbial strains with relatively high EPS production, like the genus of Zoogloea and Methyloversatilis, were reduced significantly in the BES integrated system, while the expression of the electroactive bacteria was promoted, which facilitated extracellular electron transfer (EET) and therefore the bioelectrochemical reactions. Overall, this study has presented a feasible and promising new approach for membrane fouling mitigation during the process of water treatment.
Collapse
Affiliation(s)
- Lei Xu
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China
| | - Nigel J D Graham
- Department of Civil and Environmental Engineering, Imperial College London, South Kensington Campus, London, SW7 2AZ, United Kingdom
| | - Chaocheng Wei
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China
| | - Li Zhang
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China
| | - Wenzheng Yu
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China.
| |
Collapse
|
33
|
Waldman P, Lucas FS, Varrault G, Moulin L, Wurtzer S. Hydrophobic Organic Matter Promotes Coxsackievirus B5 Stabilization and Protection from Heat. FOOD AND ENVIRONMENTAL VIROLOGY 2020; 12:118-129. [PMID: 31912415 DOI: 10.1007/s12560-019-09418-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/27/2019] [Accepted: 12/30/2019] [Indexed: 05/28/2023]
Abstract
In urban rivers, many of which are used for drinking water production, viruses encounter a range of particulate, colloidal, and dissolved organic and inorganic compounds. To date, the impact of environmental organic matter on virus persistence in the environment has received little attention. In the present study, fresh water was fractioned to separate particulate natural organic matter from dissolved forms. Each fraction was tested for its ability to promote coxsackievirus B5 resistance to heat inactivation. Our results demonstrate that, at natural concentrations, environmental waters contain particulate or dissolved compounds that are able to protect viruses from heat. We also show that hydrophobic compounds promote an efficient protection against heat inactivation. This study suggests that local conditions encountered by viruses in the environment could greatly impact their persistence.
Collapse
Affiliation(s)
- P Waldman
- Laboratoire Eau Environnement Et Systèmes Urbains (LEESU, UMR MA 102), Faculté des Sciences Et Technologie, Université Paris-Est, 61 Avenue du Général de Gaulle, 94000, Créteil, France
| | - F S Lucas
- Laboratoire Eau Environnement Et Systèmes Urbains (LEESU, UMR MA 102), Faculté des Sciences Et Technologie, Université Paris-Est, 61 Avenue du Général de Gaulle, 94000, Créteil, France
| | - G Varrault
- Laboratoire Eau Environnement Et Systèmes Urbains (LEESU, UMR MA 102), Faculté des Sciences Et Technologie, Université Paris-Est, 61 Avenue du Général de Gaulle, 94000, Créteil, France
| | - L Moulin
- Eau de Paris, DRDQE, 33 Avenue Jean Jaurès, 94200, Ivry sur Seine, France.
| | - S Wurtzer
- Eau de Paris, DRDQE, 33 Avenue Jean Jaurès, 94200, Ivry sur Seine, France
| |
Collapse
|
34
|
Salt Enhances the Thermostability of Enteroviruses by Stabilizing Capsid Protein Interfaces. J Virol 2020; 94:JVI.02176-19. [PMID: 32213614 DOI: 10.1128/jvi.02176-19] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2019] [Accepted: 03/11/2020] [Indexed: 12/11/2022] Open
Abstract
Enteroviruses are common agents of infectious disease that are spread by the fecal-oral route. They are readily inactivated by mild heat, which causes the viral capsid to disintegrate or undergo conformational change. While beneficial for the thermal treatment of food or water, this heat sensitivity poses challenges for the stability of enterovirus vaccines. The thermostability of an enterovirus can be modulated by the composition of the suspending matrix, though the effects of the matrix on virus stability are not understood. Here, we determined the thermostability of four enterovirus strains in solutions with various concentrations of NaCl and different pH values. The experimental findings were combined with molecular modeling of the protein interaction forces at the pentamer and the protomer interfaces of the viral capsids. While pH only had a modest effect on thermostability, increasing NaCl concentrations raised the breakpoint temperatures of all viruses tested by up to 20°C. This breakpoint shift could be explained by an enhancement of the van der Waals attraction forces at the two protein interfaces. In comparison, the (net repulsive) electrostatic interactions were less affected by NaCl. Depending on the interface considered, the breakpoint temperature shifted by 7.5 or 5.6°C per 100-kcal/(mol·Å) increase in protein interaction force.IMPORTANCE The genus Enterovirus encompasses important contaminants of water and food (e.g., coxsackieviruses), as well as viruses of acute public health concern (e.g., poliovirus). Depending on the properties of the surrounding matrix, enteroviruses exhibit different sensitivities to heat, which in turn influences their persistence in the environment, during food treatment, and during vaccine storage. Here, we determined the effect of NaCl and pH on the heat stability of different enteroviruses and related the observed effects to changes in protein interaction forces in the viral capsid. We demonstrate that NaCl renders enteroviruses thermotolerant and that this effect stems from an increase in van der Waals forces at different protein subunits in the viral capsid. This work sheds light on the mechanism by which salt enhances virus stability.
Collapse
|
35
|
Rockey N, Young S, Kohn T, Pecson B, Wobus CE, Raskin L, Wigginton KR. UV Disinfection of Human Norovirus: Evaluating Infectivity Using a Genome-Wide PCR-Based Approach. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2020; 54:2851-2858. [PMID: 31976661 DOI: 10.1021/acs.est.9b05747] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
The removal and inactivation of infectious human norovirus (HuNoV) is a major focus in water purification, but the effectiveness of disinfection processes on norovirus is largely unknown owing to the lack of a readily available infectivity assay. In particular, norovirus behavior through unit processes may be over- or underestimated using current approaches for assessing HuNoV infectivity (e.g., surrogates, molecular methods). Here, we fill a critical knowledge gap by estimating inactivation data for HuNoV after exposure to UV254, a commonly used disinfection process in the water industry. Specifically, we used a PCR-based approach that accurately tracks positive-sense single-stranded RNA virus inactivation without relying on culturing methods. We first confirmed that the approach is valid with a culturable positive-sense single-stranded RNA human virus, coxsackievirus B5, by applying both qPCR- and culture-based methods to measure inactivation kinetics with UV254 treatment. We then applied the qPCR-based method to establish a UV254 inactivation curve for HuNoV (inactivation rate constant = 0.27 cm2 mJ-1). Based on a comparison with previously published data, HuNoV exhibited similar UV254 susceptibility compared with other enteric single-stranded RNA viruses (e.g., Echovirus 12, feline calicivirus) but degraded much faster than MS2 (inactivation rate constant = 0.14 cm2 mJ-1). In addition to establishing a HuNoV inactivation rate constant, we developed an approach using a single qPCR assay that can be applied to estimate HuNoV inactivation in UV254 disinfection systems.
Collapse
Affiliation(s)
- Nicole Rockey
- Department of Civil & Environmental Engineering, University of Michigan, Ann Arbor 48109, Michigan, United States
| | - Suzanne Young
- Laboratory of Environmental Chemistry, School of Architecture, Civil & Environmental Engineering (ENAC), École Polytechnique Fédérale de Lausanne, Lausanne 1015, Switzerland
| | - Tamar Kohn
- Laboratory of Environmental Chemistry, School of Architecture, Civil & Environmental Engineering (ENAC), École Polytechnique Fédérale de Lausanne, Lausanne 1015, Switzerland
| | - Brian Pecson
- Trussell Technologies, Inc., Oakland 94612, California, United States
| | - Christiane E Wobus
- Department of Microbiology & Immunology, University of Michigan, Ann Arbor 48109, Michigan, United States
| | - Lutgarde Raskin
- Department of Civil & Environmental Engineering, University of Michigan, Ann Arbor 48109, Michigan, United States
| | - Krista R Wigginton
- Department of Civil & Environmental Engineering, University of Michigan, Ann Arbor 48109, Michigan, United States
| |
Collapse
|
36
|
Young S, Torrey J, Bachmann V, Kohn T. Relationship Between Inactivation and Genome Damage of Human Enteroviruses Upon Treatment by UV 254, Free Chlorine, and Ozone. FOOD AND ENVIRONMENTAL VIROLOGY 2020; 12:20-27. [PMID: 31664651 DOI: 10.1007/s12560-019-09411-2] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/29/2019] [Accepted: 10/12/2019] [Indexed: 05/07/2023]
Abstract
Quantitative PCR (qPCR) is a convenient tool for monitoring virus concentrations in water and wastewater treatment trains, though it only informs about virus presence, but not infectivity. This limitation can be overcome if the relationship between infectivity loss and genome decay induced by a given disinfectant is known. Here, we performed inactivation experiments using two human enteroviruses, Coxsackievirus B5 and Echovirus 11, with three disinfection methods: low-pressure ultraviolet light (UV254), free chlorine (FC), and ozone. We compared the inactivation rates as measured by culturing to the decay rates of the whole genome, to evaluate the extent of qPCR-measurable genome damage as a function of inactivation. To determine genome damage, we used an approach that estimates damage across the full viral genome from the measured decay of multiple amplicons distributed across the viral genome. Correlations between inactivation and genome decay were observed for all viruses and all disinfection treatments, but results showed that even among closely related viruses, disinfection methods can damage the viral genome to different extents and that genome damage does not necessarily translate to inactivation. For both viruses, UV254 treatment had the closest relationship between inactivation and genome decay and with ozone, the rate of genome decay exceeded the inactivation rate. Finally, for FC, the ratios between methods were vastly different between viruses. This work provides the basis to relate qPCR measurements to infectivity loss and enables the establishment of molecular monitoring tools for assessing enterovirus inactivation during disinfection treatments of water and wastewater.
Collapse
Affiliation(s)
- Suzanne Young
- Laboratory of Environmental Chemistry, School of Architecture, Civil and Environmental Engineering (ENAC), École Polytechnique Fédérale de Lausanne (EPFL), 1015, Lausanne, Switzerland
| | - Jason Torrey
- Laboratory of Environmental Chemistry, School of Architecture, Civil and Environmental Engineering (ENAC), École Polytechnique Fédérale de Lausanne (EPFL), 1015, Lausanne, Switzerland
| | - Virginie Bachmann
- Laboratory of Environmental Chemistry, School of Architecture, Civil and Environmental Engineering (ENAC), École Polytechnique Fédérale de Lausanne (EPFL), 1015, Lausanne, Switzerland
| | - Tamar Kohn
- Laboratory of Environmental Chemistry, School of Architecture, Civil and Environmental Engineering (ENAC), École Polytechnique Fédérale de Lausanne (EPFL), 1015, Lausanne, Switzerland.
| |
Collapse
|
37
|
Rachmadi AT, Kitajima M, Kato T, Kato H, Okabe S, Sano D. Required Chlorination Doses to Fulfill the Credit Value for Disinfection of Enteric Viruses in Water: A Critical Review. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2020; 54:2068-2077. [PMID: 31927958 DOI: 10.1021/acs.est.9b01685] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
A credit value of virus inactivation has been assigned to the disinfection step in international and domestic guidelines for wastewater reclamation and reuse. To fulfill the credit value for water disinfection, water engineers need to apply an appropriate disinfection strength, expressed as a CT value (mg × min/L), which is a product of disinfectant concentration and contact time, against enteric viruses in wastewater. In the present study, we extracted published experimental data on enteric virus inactivation using free chlorine and monochloramine and applied the Tobit analysis and simple linear regression analysis to calculate the range of CT values (mg × min/L) needed for 4-log10 inactivation. Data were selected from peer-reviewed papers containing kinetics data of virus infectivity and chlorine residual in water. Coxsackie B virus and echovirus require higher CT values (lower susceptibility) for 4-log10 inactivation than adenovirus and a human norovirus surrogate (murine norovirus) with free chlorine. On the other hand, adenovirus has lower susceptibility to monochloramine compared to murine norovirus, coxsackievirus, and echovirus. The factors that influence the required CT value are virus type, pH, water temperature, and water matrix. This systematic review demonstrates that enteroviruses and adenovirus are appropriate representative enteric viruses to evaluate water disinfection using free chlorine and monochloramine, respectively.
Collapse
Affiliation(s)
- Andri Taruna Rachmadi
- Department of Frontier Science for Advanced Environment, Graduate School of Environmental Studies , Tohoku University , Aoba 6-6-06, Aramaki, Aoba-ku , Sendai , Miyagi 980-8579 , Japan
- Division of Environmental Engineering , Hokkaido University , North 13, West 8, Kita-ku , Sapporo , Hokkaido 060-8628 , Japan
- Water Desalination and Reuse Center (WDRC) , King Abdullah University of Science and Technology (KAUST) , Thuwal 23955-6900 , Saudi Arabia
| | - Masaaki Kitajima
- Division of Environmental Engineering , Hokkaido University , North 13, West 8, Kita-ku , Sapporo , Hokkaido 060-8628 , Japan
| | - Tsuyoshi Kato
- Division of Electronics and Informatics, Faculty of Science and Technology , Gunma University , Tenjin-cho 1-5-1 , Kiryu , Gunma 376-8515 , Japan
- Center for Research on Adoption of NextGen Transportation Systems (CRANTS) , Gunma University , Aramaki-machi 4-2 , Maebashi , Gunma 371-8510 , Japan
- Integrated Institute for Regulatory Science , Waseda University , Tsurumaki-cho 513, Shinjuku-ku , Tokyo 162-0041 , Japan
| | - Hiroyuki Kato
- Japan Institute of Wastewater Engineering and Technology , 3-1 Suido-Cho, Shinjuku-ku , Tokyo 162-0811 , Japan
- New Industry Creation Hatchery Center , Tohoku University , Aoba 6-6-10, Aramaki, Aoba-ku , Sendai , Miyagi 980-8579 , Japan
| | - Satoshi Okabe
- Division of Environmental Engineering , Hokkaido University , North 13, West 8, Kita-ku , Sapporo , Hokkaido 060-8628 , Japan
| | - Daisuke Sano
- Department of Frontier Science for Advanced Environment, Graduate School of Environmental Studies , Tohoku University , Aoba 6-6-06, Aramaki, Aoba-ku , Sendai , Miyagi 980-8579 , Japan
- Department of Civil and Environmental Engineering , Tohoku University , Aoba 6-6-06, Aramaki, Aoba-ku , Sendai , Miyagi 980-8579 , Japan
| |
Collapse
|
38
|
Control of Waterborne Human Viruses by Indigenous Bacteria and Protists Is Influenced by Temperature, Virus Type, and Microbial Species. Appl Environ Microbiol 2020; 86:AEM.01992-19. [PMID: 31732569 DOI: 10.1128/aem.01992-19] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2019] [Accepted: 11/04/2019] [Indexed: 11/20/2022] Open
Abstract
Human viruses are ubiquitous contaminants in surface waters, where they can persist over extended periods of time. Among the factors governing their environmental persistence, the control (removal or inactivation) by microorganisms remains poorly understood. Here, we determined the contribution of indigenous bacteria and protists to the decay of human viruses in surface waters. Incubation of echovirus 11 (E11) in freshwater from Lake Geneva and seawater from the Mediterranean Sea led to a 2.5-log10 reduction in the infectious virus concentration within 48 h at 22°C, whereas E11 was stable in sterile controls. The observed virus reduction was attributed to the action of both bacteria and protists in the biologically active matrices. The effect of microorganisms on viruses was temperature dependent, with a complete inhibition of microbial virus control in lake water at temperatures of ≤16°C. Among three protist isolates tested (Paraphysomonas sp., Uronema marinum, and Caecitellus paraparvulus), Caecitellus paraparvulus was particularly efficient at controlling E11 (2.1-log10 reduction over 4 days with an initial protist concentration of 103 cells ml-1). In addition, other viruses (human adenovirus type 2 and bacteriophage H6) exhibited different grazing kinetics than E11, indicating that the efficacy of antiviral action also depended on the type of virus. In conclusion, indigenous bacteria and protists in lake water and seawater can modulate the persistence of E11. These results pave the way for further research to understand how microorganisms control human viral pathogens in aquatic ecosystems and to exploit this process as a treatment solution to enhance microbial water safety.IMPORTANCE Waterborne human viruses can persist in the environment, causing a risk to human health over long periods of time. In this work, we demonstrate that in both freshwater and seawater environments, indigenous bacteria and protists can graze on waterborne viruses and thereby reduce their persistence. We furthermore demonstrate that the efficiency of the grazing process depends on temperature, virus type, and protist species. These findings may facilitate the design of biological methods for the disinfection of water and wastewater.
Collapse
|
39
|
Silverman AI, Boehm AB. Systematic Review and Meta-Analysis of the Persistence and Disinfection of Human Coronaviruses and Their Viral Surrogates in Water and Wastewater. ENVIRONMENTAL SCIENCE & TECHNOLOGY LETTERS 2020; 7:544-553. [PMID: 37566367 PMCID: PMC7294895 DOI: 10.1021/acs.estlett.0c00313] [Citation(s) in RCA: 95] [Impact Index Per Article: 23.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Revised: 05/28/2020] [Accepted: 05/28/2020] [Indexed: 05/18/2023]
Abstract
A systematic review and meta-analysis was conducted to identify decay rate constants (k) of human coronaviruses and their viral surrogates (i.e., animal coronaviruses and the enveloped bacteriophage Phi6) in water and wastewater and disinfection rates with exposure to free chlorine and germicidal ultraviolet light (UV254). Here, 73 k were identified, with only 12 for human coronaviruses, as opposed to animal coronaviruses or Phi6. In the absence of disinfectants, k increased with temperature. Between 22 and 25 °C, mean k for coronaviruses ranged from 0.19 ± 0.06 d-1 in laboratory buffer (n = 4) to 2.9 ± 0.03 d-1 in sterilized wastewater (n = 3), which are within the ranges observed for Phi6 and nonenveloped viruses. No free chlorine or UV254 disinfection studies for coronaviruses were identified that met the systematic review inclusion criteria, although evidence from the literature suggests that coronaviruses would be inactivated if disinfectant doses recommended for nonenveloped viruses were applied. Three disinfection experiments were identified for Phi6. However, given different genome compositions and virion structures between coronaviruses and Phi6, it is not clear whether Phi6 should be used as a surrogate for evaluating free chlorine or UV254k. Therefore, there is a critical need for additional studies that specifically evaluate disinfection kinetics of coronaviruses in the aqueous environment.
Collapse
Affiliation(s)
- Andrea I. Silverman
- Department of Civil and Urban Engineering,
New York University Tandon School of Engineering, 6 Metrotech
Center, Brooklyn, New York 11201, United States
- Department of Global Health, New York
University School of Global Public Health, New York, New York 10012,
United States
| | - Alexandria B. Boehm
- Department of Civil and Environmental Engineering,
Stanford University, Stanford, California 94305,
United States
| |
Collapse
|
40
|
Wolf C, Pavese A, von Gunten U, Kohn T. Proxies to monitor the inactivation of viruses by ozone in surface water and wastewater effluent. WATER RESEARCH 2019; 166:115088. [PMID: 31541791 DOI: 10.1016/j.watres.2019.115088] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/25/2019] [Revised: 09/11/2019] [Accepted: 09/12/2019] [Indexed: 05/24/2023]
Abstract
Ozone treatment is an effective barrier against viral pathogens, wherefore it is an integral part of many water and wastewater treatment trains. However, the efficacy of ozone treatment remains difficult to monitor, due to the lack of methods to track virus inactivation in real-time. The goal of this work was to identify easy-to-measure proxies to monitor virus inactivation during water and wastewater treatment by ozone. Proxies considered were the abatement in UV absorbance at 254 nm (UV254) and carbamazepine (CBZ), a ubiquitous organic micropollutant with a similar abatement rate constant as human viruses. The proxies, as well as the inactivation of two viruses (MS2 coliphage and coxsackievirus B5) were measured in surface water and in a secondary wastewater effluent as a function of the specific ozone dose (mgO3/mg dissolved organic carbon). Virus inactivation was rapid in both matrices, but was more efficient in surface water. This trend was also evident when inactivation was assessed as a function of the ozone exposure to account for the different ozone demand of the two water types. Both proxies, as well as the specific ozone dose, were correlated with virus inactivation. The correlations depended only weakly on the virus species, but - with the exception of CBZ abatement - differed between the two water types. Finally, predictive relationships were established using Bayesian power models, to estimate virus inactivation based on the measurement of a proxy. The models were then applied to estimate the MS2 inactivation in a pilot-scale ozone reactor that treats surface water of Lake Zurich. All proxies yielded good estimates of the actual MS2 inactivation in the pilot plant, indicating that the proxy-inactivation relationships established in the laboratory can also be applied to flow-through reactors. This study confirms that ozone is a highly effective disinfectant for viruses in both surface water and wastewater, and that the abatement of UV254 and CBZ can be used to track virus inactivation during water and wastewater treatment.
Collapse
Affiliation(s)
- Camille Wolf
- Laboratory of Environmental Chemistry, School of Architecture, Civil and Environmental Engineering (ENAC), École Polytechnique Fédérale de Lausanne (EPFL), CH-1015, Lausanne, Switzerland
| | - Annalisa Pavese
- Laboratory of Environmental Chemistry, School of Architecture, Civil and Environmental Engineering (ENAC), École Polytechnique Fédérale de Lausanne (EPFL), CH-1015, Lausanne, Switzerland
| | - Urs von Gunten
- Laboratory for Water Quality and Treatment, School of Architecture, Civil and Environmental Engineering (ENAC), École Polytechnique Fédérale de Lausanne (EPFL), CH-1015, Lausanne, Switzerland; Eawag, Swiss Federal Institute of Aquatic Science and Technology, Dübendorf, Switzerland
| | - Tamar Kohn
- Laboratory of Environmental Chemistry, School of Architecture, Civil and Environmental Engineering (ENAC), École Polytechnique Fédérale de Lausanne (EPFL), CH-1015, Lausanne, Switzerland.
| |
Collapse
|
41
|
Boehm AB, Silverman AI, Schriewer A, Goodwin K. Systematic review and meta-analysis of decay rates of waterborne mammalian viruses and coliphages in surface waters. WATER RESEARCH 2019; 164:114898. [PMID: 31404902 DOI: 10.1016/j.watres.2019.114898] [Citation(s) in RCA: 68] [Impact Index Per Article: 13.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/15/2019] [Revised: 07/04/2019] [Accepted: 07/21/2019] [Indexed: 05/04/2023]
Abstract
Surface waters are essential natural resources. They are also receiving waters for a variety of anthropogenic waste streams that carry a myriad of pollutants including pathogens. Watershed and fate and transport models can help inform the spatial and temporal extent of microbial pollution from point and non-point sources and thus provide useful information for managing surface waters. Viruses are particularly important water-related pathogens because they often have a low infectious dose, which means that ingestion of even a small volume of water containing a low concentration of virions has the potential to cause disease. We conducted a systematic review of the literature, following best practices, to gather decay rate constants (k) of mammalian waterborne viruses (enteroviruses, adenoviruses, noroviruses, astroviruses, rotaviruses, and hepatitis A viruses) and coliphages in raw surface waters to aid in the parameterization of virus fate and transport models. We identified 562 k values from the literature, with the largest number identified for enteroviruses and coliphages and the smallest for astrovirus, hepatitis A virus, and norovirus. Average k values for each virus varied from 0.07 to 0.9 per day, in order from smallest to largest: Norwalk virus (i.e., noroviruses) < Human astrovirus < Mastadenovirus (i.e., adenoviruses) < Hepatovirus A (i.e., hepatitis A viruses) < Rotavirus A < coliphages < Enterovirus. A meta-analysis investigated how k varied among viruses for experiments conducted with different virus serotypes or species at different temperatures, salinities, and sunlight exposures, and for experiments that enumerated viruses using different methodologies. Virus species or serotype did not affect k among decay experiments. k values were generally larger for experiments conducted at higher temperatures, in sunlight, and in estuarine waters, and enumerated using culture methods. k values were statistically different between virus types with Norwalk virus, Hepatovirus A, and Mastadenovirus having smaller k values than other viruses, controlling for experimental condition and enumeration method. While F+ coliphage k values were similar to those of Enterovirus, Human astrovirus, and Rotavirus A, they were different from those of the other mammalian viruses. This compilation of coliphage and mammalian virus k values provides essential information for researchers and risk assessors who model virus fate and transport in surface waters and identifies avenues for future research to fill knowledge gaps.
Collapse
Affiliation(s)
- Alexandria B Boehm
- Department of Civil and Environmental Engineering, Stanford University, Stanford, CA, 94305, USA.
| | - Andrea I Silverman
- Department of Civil and Urban Engineering, Tandon School of Engineering, New York University, Brooklyn, NY, 11201, USA; College of Global Public Health, New York University, New York, NY, 10012, USA
| | - Alexander Schriewer
- Weston Solutions, Inc., 5817 Dryden Place Suite 101, Carlsbad, CA, 92008, USA
| | - Kelly Goodwin
- Atlantic Oceanographic and Meteorological Laboratory, National Oceanic and Atmospheric Administration (stationed at NOAA/NMFS/SWFSC, La Jolla, CA), Miami, FL, USA
| |
Collapse
|
42
|
Differences in Viral Disinfection Mechanisms as Revealed by Quantitative Transfection of Echovirus 11 Genomes. Appl Environ Microbiol 2019; 85:AEM.00961-19. [PMID: 31076437 DOI: 10.1128/aem.00961-19] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2019] [Accepted: 05/06/2019] [Indexed: 01/30/2023] Open
Abstract
Virus inactivation mechanisms can be elucidated by methods that measure the loss of specific virus functionality (e.g., host attachment, genome internalization, and genome replication). Genome functionality is frequently assessed by PCR-based methods, which are indirect and potentially inaccurate; genome damage that affects detection by high-fidelity PCR enzymes may not adversely affect the ability of actual cellular enzymes to produce functional virus. Therefore, we developed here a transfection-based assay to quantitatively determine viral genome functionality by inserting viral RNA into host cells directly to measure their ability to produce new functional viruses from damaged viral genomes. Echovirus 11 was treated with ozone, free chlorine (FC), UV light at 254 nm (UV254), or heat, and then the reductions in genome functionality and infectivity were compared. Ozone reduced genome functionality proportionally to infectivity, indicating that genome damage is the main mechanism of virus inactivation. In contrast, FC caused little or no loss of genome functionality compared to infectivity, indicating a larger role for protein damage. For UV254, genome functionality loss accounted for approximately 60% of virus inactivation, with the remainder presumably due to protein damage. Heat treatment resulted in no reduction in genome functionality, in agreement with the understanding that heat inactivation results from capsid damage. Our results indicate that there is a fundamental difference between genome integrity reductions measured by PCR enzymes in previous studies and actual genome functionality (whether the genome can produce virus) after disinfection. Compared to PCR, quantitative transfection assays provide a more realistic picture of actual viral genome functionality and overall inactivation mechanisms during disinfection.IMPORTANCE This study provides a new tool for assessing virus inactivation mechanisms by directly measuring a viral genome's ability to produce new viruses after disinfection. In addition, we identify a potential pitfall of PCR for determining virus genome damage, which does not reflect whether a genome is truly functional. The results presented here using quantitative transfection corroborate previously suggested virus inactivation mechanisms for some virus inactivation methods (heat) while bringing additional insights for others (ozone, FC, and UV254). The developed transfection method provides a more mechanistic approach for the assessment of actual virus inactivation by common water disinfectants.
Collapse
|
43
|
Silverman AI, Tay N, Machairas N. Comparison of biological weighting functions used to model endogenous sunlight inactivation rates of MS2 coliphage. WATER RESEARCH 2019; 151:439-446. [PMID: 30639729 DOI: 10.1016/j.watres.2018.12.015] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/29/2018] [Revised: 12/05/2018] [Accepted: 12/06/2018] [Indexed: 05/20/2023]
Abstract
Sunlight inactivation is important for disinfection of viruses in sunlit waters. As such, attempts have been made to predict the endogenous photoinactivation rate of bacteriophage MS2 using biological weighting functions, which describe microorganism sensitivity to sunlight inactivation as a function of wavelength. In this study, four biological weighting function models were compared to assess their ability to predict endogenous inactivation rates (kendo) of MS2. Previously-published and newly-collected datasets consisting of an incident irradiance spectrum (used as an input to the model) and a measured inactivation rate (kobs) were used for model validation and comparison. kendo values predicted by each model were compared with measured kobs to evaluate the ability of each biological weighting function to predict endogenous sunlight inactivation rates. A model previously developed by Mattle et al. (Env. Sci. Technol. 49, 334-342) over-predicted inactivation rates, whereas the other three models - a model from Fisher et al. (Env. Sci. Technol. 45, 9249-9255), a new model developed in this study, and a modification of the model by Mattle et al. (developed as part of this study) - were better able to estimate inactivation rates. The biological relevance of the spectral shape of each biological weighting function is discussed.
Collapse
Affiliation(s)
- Andrea I Silverman
- New York University, Tandon School of Engineering, Department of Civil & Urban Engineering, Brooklyn, NY, 11201, USA; New York University, College of Global Public Health, New York, NY, 10003, USA.
| | - Nerissa Tay
- New York University, Tandon School of Engineering, Department of Civil & Urban Engineering, Brooklyn, NY, 11201, USA
| | - Nikolaos Machairas
- New York University, Tandon School of Engineering, Department of Civil & Urban Engineering, Brooklyn, NY, 11201, USA
| |
Collapse
|
44
|
McClary JS, Ramos NA, Boehm AB. Photoinactivation of uncultured, indigenous enterococci. ENVIRONMENTAL SCIENCE. PROCESSES & IMPACTS 2019; 21:104-112. [PMID: 30525134 DOI: 10.1039/c8em00443a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Enterococci are used to monitor recreational water quality worldwide, so understanding their fate and transport in the environment is essential to the protection of human health. As such, researchers have documented enterococci inactivation under various exposure conditions and in diverse water matrices. However, the majority of studies have been performed using lab-cultured bacteria, which are distinct from indigenous, uncultured bacteria found in the environment. Here we investigate the photoinactivation of indigenous, uncultured enterococci from a range of sources, including wastewater treatment plants (WWTPs), marine beaches, urban streams, and a wastewater-influenced pond. We concentrated indigenous enterococci from their sources using filtration and centrifugation, placed them in a clear buffer solution, and then exposed them to simulated sunlight to measure their photoinactivation rates. First order decay rate constants (k) of indigenous, uncultured enterococci spanned an order of magnitude, from 0.3 to 2.3 m2 kJUVB-1. k values of indigenous enterococci from WWTPs tended to be larger than those from surface waters. The k value of lab-cultured Enterococcus faecalis was larger than those of indigenous, uncultured enterococci from most sources. Negative associations between the fraction of pigmented enterococci and sunlight susceptibility were observed. This work suggests that caution should be taken when extending results on bacterial photoinactivation obtained using lab-cultured bacteria to environmental bacteria, and that enterococci pigmentation may be a useful metric for estimating photoinactivation rate constants.
Collapse
Affiliation(s)
- Jill S McClary
- Civil & Environmental Engineering, Stanford University, Stanford, CA, USA.
| | | | | |
Collapse
|