1
|
Torres-Martínez JA, Mahlknecht J, Kumar M, Loge FJ, Kaown D. Advancing groundwater quality predictions: Machine learning challenges and solutions. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 949:174973. [PMID: 39053524 DOI: 10.1016/j.scitotenv.2024.174973] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/01/2024] [Revised: 06/22/2024] [Accepted: 07/20/2024] [Indexed: 07/27/2024]
Abstract
Machine learning (ML) is revolutionizing groundwater quality research by enhancing predictive accuracy and management strategies for contamination. This comprehensive review explores the evolution of ML technologies and their integration into environmental science, assessing 230 papers to understand the advancements and challenges in groundwater quality research. It reveals that a substantial portion of the research neglects critical preprocessing steps, crucial for model accuracy, with 83 % of the studies overlooking this phase. Furthermore, while model optimization is more commonly addressed, being implemented in 65 % of the papers, there is a noticeable gap in model interpretability, with only 15 % of the research providing explanations for model outcomes. Comparative evaluation of ML algorithms and careful selection of evaluation metrics are deemed essential for determining model fitness and reliability. The review underscores the need for interdisciplinary collaboration, methodological rigor, and continuous innovation to advance ML in groundwater management. By addressing these challenges and implementing solutions, the full potential of ML can be harnessed to tackle complex environmental issues and ensure sustainable groundwater management. This comprehensive and critical review paper can serve as a guiding framework to establish minimum standards for developing ML in groundwater quality studies.
Collapse
Affiliation(s)
- Juan Antonio Torres-Martínez
- Escuela de Ingeniería y Ciencias, Tecnologico de Monterrey, Campus Monterrey, Eugenio Garza Sada 2501, Monterrey, NL 64849, Mexico
| | - Jürgen Mahlknecht
- Escuela de Ingeniería y Ciencias, Tecnologico de Monterrey, Campus Monterrey, Eugenio Garza Sada 2501, Monterrey, NL 64849, Mexico.
| | - Manish Kumar
- Escuela de Ingeniería y Ciencias, Tecnologico de Monterrey, Campus Monterrey, Eugenio Garza Sada 2501, Monterrey, NL 64849, Mexico; School of Engineering, University of Petroleum & Energy Studies, Dehradun, Uttarakhand 248007, India
| | - Frank J Loge
- Department of Civil and Environmental Engineering, University of California Davis, One Shields Avenue, Davis, CA 95616, USA
| | - Dugin Kaown
- School of Earth and Environmental Sciences, Seoul National University, Seoul 08826, Republic of Korea
| |
Collapse
|
2
|
Molina CA, Quiroz-Moreno C, Jarrín-V P, Díaz M, Yugsi E, Pérez-Galarza J, Baldeón-Rojas L. Bacterial community assessment of drinking water and downstream distribution systems in highland localities of Ecuador. JOURNAL OF WATER AND HEALTH 2024; 22:536-549. [PMID: 38557569 DOI: 10.2166/wh.2024.290] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Accepted: 01/23/2024] [Indexed: 04/04/2024]
Abstract
Bacterial communities in drinking water provide a gauge to measure quality and confer insights into public health. In contrast to urban systems, water treatment in rural areas is not adequately monitored and could become a health risk. We performed 16S rRNA amplicon sequencing to analyze the microbiome present in the water treatment plants at two rural communities, one city, and the downstream water for human consumption in schools and reservoirs in the Andean highlands of Ecuador. We tested the effect of water treatment on the diversity and composition of bacterial communities. A set of physicochemical variables in the sampled water was evaluated and correlated with the structure of the observed bacterial communities. Predominant bacteria in the analyzed communities belonged to Proteobacteria and Actinobacteria. The Sphingobium genus, a chlorine resistance group, was particularly abundant. Of health concern in drinking water reservoirs were Fusobacteriaceae, Lachnospiraceae, and Ruminococcaceae; these families are associated with human and poultry fecal contamination. We propose the latter families as relevant biomarkers for establishing local standards for the monitoring of potable water systems in highlands of Ecuador. Our assessment of bacterial community composition in water systems in the Ecuadorian highlands provides a technical background to inform management decisions.
Collapse
Affiliation(s)
- C Alfonso Molina
- Facultad de Medicina Veterinaria y Zootecnia, Universidad Central del Ecuador, Cdla. Universitaria y Gaspar de Carvajal s/n., 170521 Quito, Ecuador; Instituto de Investigación en Zoonosis (CIZ), Universidad Central del Ecuador, Cdla. Universitaria y Gaspar de Carvajal s/n., 170521, Quito, Ecuador E-mail:
| | - Cristian Quiroz-Moreno
- Department of Horticulture and Crop Science, Ohio State University, 2021 Coffey Road, Columbus OH 43210
| | - Pablo Jarrín-V
- Laboratorio de Secuenciamiento de Ácidos Nucleicos, Dirección de Gestión de la Innovación, Instituto Nacional de Biodiversidad INABIO, Pje. Rumipamba N341 y Av. de los Shyris, Quito, Ecuador
| | - Magdalena Díaz
- Instituto de Investigación en Zoonosis (CIZ), Universidad Central del Ecuador, Cdla. Universitaria y Gaspar de Carvajal s/n., 170521, Quito, Ecuador; Facultad de Ingeniería Química, Universidad Central del Ecuador, Ritter s/n y Bolivia, 170521 Quito, Ecuador; Institute of Integrative Systems Biology (I2SysBio), University of Valencia and Consejo Superior de Investigaciones Científicas (CSIC), Carrer del Catedràtic Agustín Escardino Benlloch, 46980 Paterna, Valencia, Spain
| | - Elizabeth Yugsi
- Centro de Biotecnología 'Dr Daniel Alkalay Lowitt', Universidad Técnica Federico Santa María, General Bari 699, 2390136, Valparaíso, Chile
| | - Jorge Pérez-Galarza
- Facultad de Ciencias Médicas, Universidad Central del Ecuador, Iquique N14-121 y Sodiro, Quito, Ecuador; Instituto de Investigación en Biomedicina, Universidad Central del Ecuador, Capitán Giovanni Calles y Derby, Quito, Ecuador
| | - Lucy Baldeón-Rojas
- Facultad de Ciencias Médicas, Universidad Central del Ecuador, Iquique N14-121 y Sodiro, Quito, Ecuador; Instituto de Investigación en Biomedicina, Universidad Central del Ecuador, Capitán Giovanni Calles y Derby, Quito, Ecuador
| |
Collapse
|
3
|
Mkhwanazi F, Mazibuko T, Mosoma O, Rathebe M, Patel M. Comparison of PetrifilmTM AC and pour plate techniques used for the heterotrophic aerobic bacterial count in water. FEMS Microbiol Lett 2024; 371:fnae029. [PMID: 38684475 PMCID: PMC11095641 DOI: 10.1093/femsle/fnae029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2023] [Revised: 04/10/2024] [Accepted: 04/25/2024] [Indexed: 05/02/2024] Open
Abstract
Heterotrophic bacteria are commonly found in water samples. While these Heterotrophic Bacterial/Plate Counts (HPC) do not necessarily indicate a health hazard, high counts provide a good indication of the efficiency of water disinfection and integrity of distribution systems. The aim of this study was to compare the PetrifimTM AC method to the pour plate technique for the testing of HPC in water samples. Artificially contaminated (192 samples) and natural water samples (25) were processed using two methods. Both methods accurately detected high, medium and low counts of HPC, producing average Z scores between -2 and +2. Paired-wise student t-test and correlation coefficient showed nonsignificant differences between the results of two methods. Acceptable repeatability and reproducibility was obtained using both the methods. Uncertainty of measurement for PetrifilmTM AC and pour plate method was found to be 2.9% and 5.4%, respectively. PetrifilmTM AC proved to be robust at 33°C and 37°C. In conclusion, PetrifimTM AC, which is easy to process, read, and less time consuming, proved to be comparable to the conventional pour plate method in establishing HPC in water. In addition, PetrifimTM AC requires less space for the processing and incubation, generate small volume of waste for disposal, and requires no equipment, except for the incubator.
Collapse
Affiliation(s)
- Faith Mkhwanazi
- Infection Control, Charlotte Maxeke Johannesburg Academic Hospital National Health Laboratory Service, 7 York Road, Parktown, Johannesburg 2193, Gauteng, South Africa
| | - Tshilidzi Mazibuko
- Infection Control, Charlotte Maxeke Johannesburg Academic Hospital National Health Laboratory Service, 7 York Road, Parktown, Johannesburg 2193, Gauteng, South Africa
| | - Olivia Mosoma
- Infection Control, Charlotte Maxeke Johannesburg Academic Hospital National Health Laboratory Service, 7 York Road, Parktown, Johannesburg 2193, Gauteng, South Africa
| | - Malefaso Rathebe
- Infection Control, Charlotte Maxeke Johannesburg Academic Hospital National Health Laboratory Service, 7 York Road, Parktown, Johannesburg 2193, Gauteng, South Africa
| | - Mrudula Patel
- Infection Control, Charlotte Maxeke Johannesburg Academic Hospital National Health Laboratory Service, 7 York Road, Parktown, Johannesburg 2193, Gauteng, South Africa
- Department of Clinical Microbiology and Infectious Diseases, School of Pathology, Faculty of Health Sciences, University of the Witwatersrand, Private Bag 3, Wits, Johannesburg 2050, South Africa
| |
Collapse
|
4
|
Eckenko R, Maiboroda O, Muzyka N, Stegniy B, Mezinov O, Rula O, Muzyka D. Circulation of Antibiotic-Resistant Escherichia coli in Wild and Domestic Waterfowl in Ukraine. Vector Borne Zoonotic Dis 2024; 24:17-26. [PMID: 37883639 DOI: 10.1089/vbz.2023.0001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2023] Open
Abstract
Background: Antibiotic resistance is becoming an increasingly urgent problem for human and animal health due to the widespread use of antibiotics in medicine, veterinary medicine, and agriculture. At the same time, the natural reservoirs of antibiotic-resistant pathogens remain unclear. Wild birds may play a role in this due to their biology. Escherichia coli is a representative indicator pathogen for antibiotic resistance studies. Materials and Methods: In 2020-2021, sampling of feces and cloacal swabs from six species of wild waterfowl (Eurasian wigeon Anas penelope, Eurasian teal Anas crecca, white-fronted goose Anser albifrons, red-breasted goose Rufibrenta ruficollis, graylag goose Anser anser, shelduck Tadorna tadorna) and from two species of domestic waterfowl (ducks and geese) was conducted in the Kherson, Zaporizhzhia, Odesa, Kharkiv, and Cherkasy regions of Ukraine. Biological material was collected, stored, and transported in cryotubes with transport medium (brain heart infusion broth [BHIB] with the addition of 15% glycerol) in liquid nitrogen. Bacteriological studies were carried out according to standard methods for the isolation and identification of microorganisms. Drug resistance of E. coli was carried out by a standard disk diffusion method. Results: Bacteria representing six families (Enterobacteriaceae, Yersiniaceae, Morganellaceae, Bacillaceae, Pseudomonadaceae, Staphylococcaceae) were isolated from clinically healthy wild birds (wigeon, Eurasian teal, white-fronted goose, red-breasted goose, mallard, graylag goose, shelduck) in the southern regions of Ukraine with isolation rates ranging from 26.7% to 100%. A total of 19 E. coli isolates were cultured from 111 samples from wild birds, and 30 isolates of E. coli were cultured from 32 poultry samples. E. coli was isolated from birds of all species. The prevalence of E. coli ranged from 5.0% to 33.3% in wild waterfowl and from 90.9% to 100% in domestic waterfowl. The prevalence of multidrug-resistant (MDR) E. coli ranged from 10.0% to 31.8% in wild and domestic waterfowl: 3 of 15 (20%) specimens from wild mallard were MDR in the Kherson region, as well as 7 of 22 domestic ducks (31.8%) and 1 of 10 geese (10%) in the Kharkiv and Cherkasy regions. Isolates from wild birds were the most resistant to ampicillin (AMP), amoxiclav (AMC), amoxicillin (AMX), doxycycline (DO), and chloramphenicol (C). Isolates from poultry were resistant to ampicillin, amoxiclav, doxycycline, amoxicillin, chloramphenicol, and enrofloxacin (EX). Most of the other E. coli isolates from wild waterfowl were classified as non-multidrug-resistant (non-MDR) forms. Analysis of antibiotic sensitivity phenotypes showed that only four antibiotic-resistant phenotypes were detected among non-MDR bacteria, whereas among the MDR bacteria, two antibiotic-resistant phenotypes were detected in mallards and six in domestic waterfowl. Conclusion: The results of this study showed that wild waterfowl in Ukraine, which live in natural conditions and do not receive any antimicrobial drugs, are carriers of E. coli that are resistant to a number of antibiotics that are actively used in industrial poultry.
Collapse
Affiliation(s)
- Ruslana Eckenko
- National Scientific Center Institute of Experimental and Clinical Veterinary Medicine (NSC IECVM), Kharkiv, Ukraine
| | - Olha Maiboroda
- National Scientific Center Institute of Experimental and Clinical Veterinary Medicine (NSC IECVM), Kharkiv, Ukraine
| | - Nataliia Muzyka
- National Scientific Center Institute of Experimental and Clinical Veterinary Medicine (NSC IECVM), Kharkiv, Ukraine
| | - Borys Stegniy
- National Scientific Center Institute of Experimental and Clinical Veterinary Medicine (NSC IECVM), Kharkiv, Ukraine
| | - Oleksandr Mezinov
- National Scientific Center Institute of Experimental and Clinical Veterinary Medicine (NSC IECVM), Kharkiv, Ukraine
- Department of Zoology, H.S. Skovoroda Kharkiv National Pedagogical University, Kharkiv, Ukraine
- The F.E. Falz-Fein Biosphere Reserve "Askania Nova" Askania-Nova Ukraine
| | - Oleksandr Rula
- National Scientific Center Institute of Experimental and Clinical Veterinary Medicine (NSC IECVM), Kharkiv, Ukraine
| | - Denys Muzyka
- National Scientific Center Institute of Experimental and Clinical Veterinary Medicine (NSC IECVM), Kharkiv, Ukraine
| |
Collapse
|
5
|
Sekgobela JM, Murei A, Khabo-Mmekoa CM, Momba MNB. Identification of fecal contamination sources of groundwater in rural areas of Vhembe District Municipality, Limpopo Province, South Africa. WATER ENVIRONMENT RESEARCH : A RESEARCH PUBLICATION OF THE WATER ENVIRONMENT FEDERATION 2023; 95:e10965. [PMID: 38151283 DOI: 10.1002/wer.10965] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/02/2023] [Revised: 10/30/2023] [Accepted: 11/30/2023] [Indexed: 12/29/2023]
Abstract
Groundwater is a valuable source of drinking water worldwide, recognized as an improved drinking water source. However, on-site sanitation systems may put groundwater at risk of fecal contamination. In the present study, two approaches were used to ascertain the sources of fecal contamination in groundwater used by communities of the Vhembe District Municipality. Overall, 87.5% of boreholes (n = 70) in the wet and 72.5% in the dry season were contaminated with Escherichia coli, and septic tank (n = 18) wastewaters displayed up to 104 cfu/mL E. coli. Host-specific Bacteroidales quantitative polymerase chain reaction (qPCR) assays established the presence of human (BacHum and HF183) and animal (Cytb, BacCan, and Pig-2Bac) genetic markers in groundwater from 15.7% of boreholes (wet) and 10% of boreholes (dry). No strong associations were founded between culturable E. coli counts and the presence/absence of marker genes for all the markers except for Cytb marker, which showed a weak significant correlation (r = 0.217; p = <0.01) between E. coli and the Cytb marker under dry seasonal conditions. Human markers and Cytb were present in the household septic tank wastewater samples. Significant differences in marker genes distribution in wastewater were observed using the Chi-squared test: HF183 (p = <0.001) and BacHum (p = <0.001). Overall, no association was recorded between markers in groundwater and in wastewater for 18 households' septic tanks. A combined culturable E. coli and host-specific Bacteroidales qPCR assays remain an appropriate approach for the identification of fecal contamination of groundwater. PRACTITIONER POINTS: Households primarily used private boreholes for drinking water, as a primary source. Most households used on-site sanitation systems, including ventilated improved pit latrines and flush toilets connected to septic tanks. Escherichia coli was detected in groundwater, and the sources of fecal contamination were humans and animals (pigs, dogs, and chickens). The presence of human and animal markers in groundwater suggests that humans and animals are liable for fecal contamination. Fecal contamination in drinking water sources poses a significant concern due to pathogenic microorganisms posing potential human health risks.
Collapse
Affiliation(s)
- Jeridah Matlhokha Sekgobela
- Department of Environmental, Water and Earth Sciences, Tshwane University of Technology, Pretoria, South Africa
| | - Arinao Murei
- Department of Environmental, Water and Earth Sciences, Tshwane University of Technology, Pretoria, South Africa
| | | | - Maggy Ndombo Benteke Momba
- Department of Environmental, Water and Earth Sciences, Tshwane University of Technology, Pretoria, South Africa
| |
Collapse
|
6
|
Choix FJ, Palacios OA, Nevarez-Moorillón GV. Traditional and new proposals for environmental microbial indicators-a review. ENVIRONMENTAL MONITORING AND ASSESSMENT 2023; 195:1521. [PMID: 37995003 DOI: 10.1007/s10661-023-12150-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2023] [Accepted: 11/18/2023] [Indexed: 11/24/2023]
Abstract
The continuous increment in world population coupled with the greatest natural resource consumption and waste generation has an enormous impact on the environment. To date, using biological indicators (bioindicators) to evaluate the biological quality of natural environments is very common. Nonetheless, selecting those suitable for each ecosystem or contaminant is one of the most important issues for environmental sciences. Bacteria and helminths are mainly related to fecal contamination, while antibiotic-resistant bacteria, fungi, viruses, and microalgae are organisms used to determine deteriorated ecosystems by diverse contaminants. Nowadays, each bioindicator is used as a specific agent of different contaminant types, but detecting and quantifying these bioindicator microorganisms can be performed from simple microscopy and culture methods up to a complex procedure based on omic sciences. Developing new techniques based on the metabolism and physiological responses of traditional bioindicators is shown in a fast environmental sensitivity analysis. Therefore, the present review focuses on analyzing different bioindicators to facilitate developing suitable monitoring environmental systems according to different pollutant agents. The traditional and new methods proposed to detect and quantify different bioindicators are also discussed. Their vital role is considered in implementing efficient ecosystem bioprospection, restoration, and conservation strategies directed to natural resource management.
Collapse
Affiliation(s)
- Francisco J Choix
- CONAHCYT - Facultad de Ciencias Químicas, Universidad Autónoma de Chihuahua, Circuito Universitario S/N, C.P. 31125, Chihuahua, Chihuahua, México.
- Facultad de Ciencias Químicas, Universidad Autónoma de Chihuahua, Circuito Universitario S/N, C.P. 31125, Chihuahua, Chihuahua, México.
| | - Oskar A Palacios
- Facultad de Ciencias Químicas, Universidad Autónoma de Chihuahua, Circuito Universitario S/N, C.P. 31125, Chihuahua, Chihuahua, México
- The Bashan Institute of Science, 1730 Post Oak Court, Auburn, AL, 36830, USA
| | | |
Collapse
|
7
|
Codony F, Dangla C, Ventolà L, Sabaté N. Phase change materials for portable isothermal incubators as a solution to shorten effective analysis times in microbiological quality control of drinking water. ENVIRONMENTAL MONITORING AND ASSESSMENT 2023; 195:1105. [PMID: 37642879 DOI: 10.1007/s10661-023-11742-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Accepted: 08/17/2023] [Indexed: 08/31/2023]
Abstract
The microbiological quality control of water for human consumption of parameters relevant as E.coli and total coliforms does not start on the field despite the existence of test methods that could make it possible. One of the things that makes this difficult is the possibility of initiating an effective and reliable incubation at the sampling site. The appearance of isothermal media with phase change materials solves this limitation. When phase change materials combine a relatively high melting heat with a suitable melting temperature adapted to the application temperature, they become excellent materials for thermal protection and for thermal energy storage. Starting the test at the same sampling point means that the effective times to obtain a result are shorter, improving water quality control. On the other hand, operationally, it also allows longer sampling routes. Both aspects are essential for managers responsible for controlling water quality for human consumption. In this work, the evidence that demonstrates the feasibility of this approach is presented.
Collapse
Affiliation(s)
- F Codony
- Laboratori d'Aigües de Mataró, carrer Hèl·lade, 17-19, 08304, Mataró, Barcelona, Spain.
| | - C Dangla
- Laboratori d'Aigües de Mataró, carrer Hèl·lade, 17-19, 08304, Mataró, Barcelona, Spain
| | - L Ventolà
- LVM Thermal Solutions, Carretera Vic n° 20 Nau 8, 17176 Sant Esteve d'en Bas, Barcelona, Spain
| | - N Sabaté
- Laboratori d'Aigües de Mataró, carrer Hèl·lade, 17-19, 08304, Mataró, Barcelona, Spain
| |
Collapse
|
8
|
Ghozzi K, Nakbi A, Challouf R, Dhiab RB. A review on microbial contamination cases in Tunisian coastal marine areas. WATER SCIENCE AND TECHNOLOGY : A JOURNAL OF THE INTERNATIONAL ASSOCIATION ON WATER POLLUTION RESEARCH 2023; 87:2142-2158. [PMID: 37186620 PMCID: wst_2023_123 DOI: 10.2166/wst.2023.123] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
Microbial pollution in marine environments is one of the critical issues with regard to the sanitary status of recreational activities and seafood harvesting due to a potential contamination by pathogenic microorganisms. This review's objectives were to identify instances of bacterial, viral and protozoan parasite pollution in the Tunisian coastal region and to make recommendations for further research. Fecal indicators such as Escherichia coli and Salmonella spp. were detected in samples of clams and mussels. Vibrionaceae species were also recorded in seawater, sediment, fish and clams in different sites from north to south with the dominance of Vibrio alginolyticus. Bivalve mollusks collected from the Tunisian coast have been revealed to harbor viruses as well as protozoan parasites. Furthermore, the isolation of multidrug-resistant bacterial strains from Tunisian coastlines proves the significant spread and circulation of antibiotic resistance caused by the massive use of antibiotics. In conclusion, we suggest intensive monitoring and cutting-edge wastewater treatment technologies to enhance seawater quality and preserve the biodiversity of aquatic life. Rapid detection techniques for the most important pathogenic microorganisms in seafood and seawater must be also developed to reduce human health risk.
Collapse
Affiliation(s)
- Khemissa Ghozzi
- Laboratoire de Biodiversité Marine, Institut National des Sciences et Technologies de la Mer, Monastir, Tunisie E-mail:
| | - Amel Nakbi
- Laboratoire de Biodiversité Marine, Institut National des Sciences et Technologies de la Mer, Monastir, Tunisie E-mail:
| | - Rafika Challouf
- Laboratoire de Biodiversité Marine, Institut National des Sciences et Technologies de la Mer, Monastir, Tunisie E-mail:
| | - Rym Ben Dhiab
- Laboratoire de Biodiversité Marine, Institut National des Sciences et Technologies de la Mer, Monastir, Tunisie E-mail:
| |
Collapse
|
9
|
Abia ALK, Baloyi T, Traore AN, Potgieter N. The African Wastewater Resistome: Identifying Knowledge Gaps to Inform Future Research Directions. Antibiotics (Basel) 2023; 12:805. [PMID: 37237708 PMCID: PMC10215879 DOI: 10.3390/antibiotics12050805] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2023] [Revised: 04/20/2023] [Accepted: 04/21/2023] [Indexed: 05/28/2023] Open
Abstract
Antimicrobial resistance (AMR) is a growing global public health threat. Furthermore, wastewater is increasingly recognized as a significant environmental reservoir for AMR. Wastewater is a complex mixture of organic and inorganic compounds, including antibiotics and other antimicrobial agents, discharged from hospitals, pharmaceutical industries, and households. Therefore, wastewater treatment plants (WWTPs) are critical components of urban infrastructure that play a vital role in protecting public health and the environment. However, they can also be a source of AMR. WWTPs serve as a point of convergence for antibiotics and resistant bacteria from various sources, creating an environment that favours the selection and spread of AMR. The effluent from WWTPs can also contaminate surface freshwater and groundwater resources, which can subsequently spread resistant bacteria to the wider environment. In Africa, the prevalence of AMR in wastewater is of particular concern due to the inadequate sanitation and wastewater treatment facilities, coupled with the overuse and misuse of antibiotics in healthcare and agriculture. Therefore, the present review evaluated studies that reported on wastewater in Africa between 2012 and 2022 to identify knowledge gaps and propose future perspectives, informing the use of wastewater-based epidemiology as a proxy for determining the resistome circulating within the continent. The study found that although wastewater resistome studies have increased over time in Africa, this is not the case in every country, with most studies conducted in South Africa. Furthermore, the study identified, among others, methodology and reporting gaps, driven by a lack of skills. Finally, the review suggests solutions including standardisation of protocols in wastewater resistome works and an urgent need to build genomic skills within the continent to handle the big data generated from these studies.
Collapse
Affiliation(s)
- Akebe Luther King Abia
- One Health Research Group, Biochemistry & Microbiology Department, University of Venda, Private Bag X5050, Thohoyandou 0950, South Africa; (T.B.); (A.N.T.)
- Environmental Research Foundation, Westville 3630, South Africa
| | - Themba Baloyi
- One Health Research Group, Biochemistry & Microbiology Department, University of Venda, Private Bag X5050, Thohoyandou 0950, South Africa; (T.B.); (A.N.T.)
| | - Afsatou N. Traore
- One Health Research Group, Biochemistry & Microbiology Department, University of Venda, Private Bag X5050, Thohoyandou 0950, South Africa; (T.B.); (A.N.T.)
| | - Natasha Potgieter
- One Health Research Group, Biochemistry & Microbiology Department, University of Venda, Private Bag X5050, Thohoyandou 0950, South Africa; (T.B.); (A.N.T.)
| |
Collapse
|
10
|
Lyons KJ, Ikonen J, Hokajärvi AM, Räsänen T, Pitkänen T, Kauppinen A, Kujala K, Rossi PM, Miettinen IT. Monitoring groundwater quality with real-time data, stable water isotopes, and microbial community analysis: A comparison with conventional methods. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 864:161199. [PMID: 36581300 DOI: 10.1016/j.scitotenv.2022.161199] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/18/2022] [Revised: 12/20/2022] [Accepted: 12/22/2022] [Indexed: 06/17/2023]
Abstract
Groundwater provides much of the world's potable water. Nevertheless, groundwater quality monitoring programmes often rely on a sporadic, slow, and narrowly focused combination of periodic manual sampling and laboratory analyses, such that some water quality deficiencies go undetected, or are detected too late to prevent adverse consequences. In an effort to address this shortcoming, we conducted enhanced monitoring of untreated groundwater quality over 12 months (February 2019-February 2020) in four shallow wells supplying potable water in Finland. We supplemented periodic manual sampling and laboratory analyses with (i) real-time online monitoring of physicochemical and hydrological parameters, (ii) analysis of stable water isotopes from groundwater and nearby surface waters, and (iii) microbial community analysis of groundwater via amplicon sequencing of the 16S rRNA gene and 16S rRNA. We also developed an early warning system (EWS) for detecting water quality anomalies by automating real-time online monitoring data collection, transfer, and analysis - using electrical conductivity (EC) and turbidity as indirect water quality indicators. Real-time online monitoring measurements were largely in fair agreement with periodic manual measurements, demonstrating their usefulness for monitoring water quality; and the findings of conventional monitoring, stable water isotopes, and microbial community analysis revealed indications of surface water intrusion and faecal contamination at some of the studied sites. With further advances in technology and affordability expected into the future, the supplementary methods used here could be more widely implemented to enhance groundwater quality monitoring - by contributing new insights and/or corroborating the findings of conventional analyses.
Collapse
Affiliation(s)
- Kevin J Lyons
- Water, Energy and Environmental Engineering Research Unit, University of Oulu, Oulu, Finland.
| | - Jenni Ikonen
- Expert Microbiology Unit, Finnish Institute for Health and Welfare, Kuopio, Finland
| | - Anna-Maria Hokajärvi
- Expert Microbiology Unit, Finnish Institute for Health and Welfare, Kuopio, Finland
| | - Teemu Räsänen
- Preventos Informatics Oy, Kuopio, Finland; Department of Environmental Technology, Savonia University of Applied Sciences, Kuopio, Finland
| | - Tarja Pitkänen
- Expert Microbiology Unit, Finnish Institute for Health and Welfare, Kuopio, Finland; Department of Food Hygiene and Environmental Health, Faculty of Veterinary Medicine, University of Helsinki, Helsinki, Finland
| | - Ari Kauppinen
- Expert Microbiology Unit, Finnish Institute for Health and Welfare, Kuopio, Finland; Animal Health Diagnostic Unit, Laboratory and Research Division, Finnish Food Authority, Helsinki, Finland
| | - Katharina Kujala
- Water, Energy and Environmental Engineering Research Unit, University of Oulu, Oulu, Finland
| | - Pekka M Rossi
- Water, Energy and Environmental Engineering Research Unit, University of Oulu, Oulu, Finland
| | - Ilkka T Miettinen
- Expert Microbiology Unit, Finnish Institute for Health and Welfare, Kuopio, Finland
| |
Collapse
|
11
|
Nisa FU, Umar R. Evaluation of physicochemical and microbiological parameters, and their correlation in Himalayan Spring Water Systems: A case study of District Kulgam of Kashmir Valley, India, Western Himalaya. ENVIRONMENTAL MONITORING AND ASSESSMENT 2023; 195:441. [PMID: 36869254 DOI: 10.1007/s10661-023-11025-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/17/2022] [Accepted: 02/13/2023] [Indexed: 06/18/2023]
Abstract
Total coliforms, E. coli, and fecal streptococci are the important indicators linked to the human health. This study investigated presence of these indicator bacteria in the Himalayan springs at various locations in the district Kulgam of Kashmir valley. A total of 30 spring water samples were collected from rural, urban, and forest areas during post-melting season 2021 and pre-melting season 2022. The springs in the area originate from the alluvium deposit, Karewa, and hard rock formations. The physicochemical parameters were found within the acceptable limits. However, nitrate and phosphate were found above the permissible limit at few sites, thus indicating the presence of anthropogenic activities in the area. Majority of the samples during both the seasons were found highly loaded with total coliforms with maximum limit of greater than 180 MPN/100 ml. E. coli and fecal streptococci were found in the range of less than 1 to more than 180 MPN/100 ml. The results of Pearson correlation of physicochemical parameters with indicator bacteria showed that chemical oxygen demand, rainfall, spring discharge, nitrate, and phosphate are the main factors affecting the concentration of indicator bacteria in the spring water at each site. Principal component analysis showed the most influencing factors of water quality in most of the spring sites are total coliforms, E. coli, fecal streptococci, rainfall, discharge, and chemical oxygen demand. The results of this study showed that the spring water is unfit for drinking purpose because of high concentration of fecal indicator bacteria.
Collapse
Affiliation(s)
- Fahim Un Nisa
- Department of Geology, Aligarh Muslim University, Uttar Pradesh, Aligarh, India
| | - Rashid Umar
- Department of Geology, Aligarh Muslim University, Uttar Pradesh, Aligarh, India.
| |
Collapse
|
12
|
Su J, Ji W, Sun X, Wang H, Kang Y, Yao B. Effects of different management practices on soil microbial community structure and function in alpine grassland. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2023; 327:116859. [PMID: 36450164 DOI: 10.1016/j.jenvman.2022.116859] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/27/2022] [Revised: 11/12/2022] [Accepted: 11/20/2022] [Indexed: 06/17/2023]
Abstract
Management practices, such as grazing exclusion and reseeding, have been implemented to mitigate the degradation of grassland. Low grazing intensities and reseeding increase grass production. Nevertheless, few studies have investigated the effects of these measures on the soil microbial community structure and function in the Qinghai Tibetan Plateau (QTP). To reveal the effects of management practices on soil microbes and give a reference to assess and improve ecosystems functions, we here evaluated the impact of various types of grazing (exclusion, seasonal, and traditional), reseeding (annual oat (Avena fatua) grassland (RO) and perennial artificial grassland cultivated >10 y), and integrated restoration (weed control and no-tillage reseeding) measures on soil microbial community structure and function in the QTP. The Shannon-Wiener diversity indices were highest for prokaryotes under RO and for fungi under integrated grassland restoration. Relative Actinobacteria abundance was higher under seasonal grazing than that under integrated grassland restoration. The latter had relatively higher abundances of Betaproteobacteria, Alphaproteobacteria, and Deltaproteobacteria and comparatively lower abundance of Thermoleophilia. There were significantly higher abundances of plant pathogens under seasonal grazing than those under other managements. There were significantly high proportions of pathotrophs and saprotrophs (10.0%) under seasonal and traditional grazing, respectively. The proportion of pathotrophs under integrated restoration (10.0%) was about seven-fold greater than that under grazing exclusion (1.5%). The relative differences among treatments in terms of soil water content, plant biomass, and soil C:N partially explained the differences in their prokaryotic community compositions. Increases in soil organic carbon and C:N may explain the observed changes in the soil fungal communities. The management practices affected soil microorganisms mainly by altering the soil nutrient profile. Grazing attracted specific pathotrophs and saprotrophs while repelling certain plant pathogens. Hence, modulations in soil microbial community structure and function must be considered in the process of planning for the implementation of grassland degradation management measures.
Collapse
Affiliation(s)
- Junhu Su
- College of Grassland Science, Key Laboratory of Grassland Ecosystem (Ministry of Education), Gansu Agricultural University, Lanzhou, 730070, China; Gansu Agricultural University-Massey University Research Centre for Grassland Biodiversity, Gansu Agricultural University, Lanzhou, 730070, China; Gansu Qilianshan Grassland Ecosystem Observation and Research Station, Wuwei, 733200, China.
| | - Weihong Ji
- Gansu Agricultural University-Massey University Research Centre for Grassland Biodiversity, Gansu Agricultural University, Lanzhou, 730070, China; Institute of Natural and Mathematical Sciences, Massey University, Private Bag, North Shore Mail Centre 0632, Auckland, 102 904rad, New Zealand
| | - Xiaomei Sun
- Gansu Agricultural University-Massey University Research Centre for Grassland Biodiversity, Gansu Agricultural University, Lanzhou, 730070, China; College of Resource and Environmental Science, Gansu Agricultural University, Lanzhou, 730070, China
| | - Haifang Wang
- Gansu Agricultural University-Massey University Research Centre for Grassland Biodiversity, Gansu Agricultural University, Lanzhou, 730070, China; College of Life Science and Technology, Gansu Agricultural University, Lanzhou, 730070, China
| | - Yukun Kang
- College of Grassland Science, Key Laboratory of Grassland Ecosystem (Ministry of Education), Gansu Agricultural University, Lanzhou, 730070, China; Gansu Agricultural University-Massey University Research Centre for Grassland Biodiversity, Gansu Agricultural University, Lanzhou, 730070, China; Gansu Qilianshan Grassland Ecosystem Observation and Research Station, Wuwei, 733200, China
| | - Baohui Yao
- College of Grassland Science, Key Laboratory of Grassland Ecosystem (Ministry of Education), Gansu Agricultural University, Lanzhou, 730070, China; Gansu Agricultural University-Massey University Research Centre for Grassland Biodiversity, Gansu Agricultural University, Lanzhou, 730070, China; Gansu Qilianshan Grassland Ecosystem Observation and Research Station, Wuwei, 733200, China
| |
Collapse
|
13
|
Li J, Zhai Y, Ge G, Xu Y, Wang C, Hu A, Han Y, Shan N, Liu B, Chen J, Wang W. Bacterial Community Composition and Function of Tropical River Ecosystem along the Nandu River on Hainan Island, China. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 20:382. [PMID: 36612703 PMCID: PMC9819888 DOI: 10.3390/ijerph20010382] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/10/2022] [Revised: 12/20/2022] [Accepted: 12/21/2022] [Indexed: 06/17/2023]
Abstract
Microorganisms play a pivotal role in nutrient cycling in aquatic ecosystems. Understanding bacterial diversity and its functional composition are crucial for aquatic ecology and protection. We investigated the bacterial community structure using 16S rRNA gene amplicons high-throughput sequencing in this study. Results showed that 105 amplicon sequence variants (ASVs) account for 43.8% of the total sequences shared by the Nandu River's lower, middle, and upper reach and the Songtao Reservoir. The dominant bacterial phylum in the Nandu River and its connected Songtao Reservoir were Proteobacteria and Actinobacteriota, respectively. The highest Chao1 and Shannon index values were found in the lower reach of the Nandu River. Beta diversity analysis showed the divergence in bacterial communities in the Nandu River and Songtao Reservoir, but not in different reaches. Among the water properties, based on the Mantel test, dissolved oxygen, total nitrogen, and nitrite significantly affected the bacterial communities. The functional profiles predicted by Tax4Fun2 showed that metabolism was the most abundant function group. The relative abundance of genetic information processing was significantly higher in the Songtao Reservoir than in the Nandu River, while the relative abundance of human diseases was significantly lower in the Songtao Reservoir than in the Nandu River. The appearance of the xenobiotics biodegradation and metabolism function group requires us to pay more attention to possible water pollution, especially at the upper reach of the Nandu River.
Collapse
Affiliation(s)
- Jinbiao Li
- School of Geographic Science, Nantong University, Nantong 226019, China
- Nanjing Institute of Environmental Sciences, Ministry of Environmental Protection, Nanjing 210042, China
- State Environmental Protection Scientific Observation and Research Station for Ecological Environment of Lake Hulun Wetland, Hulunbuir 021000, China
| | - Yangni Zhai
- School of Geographic Science, Nantong University, Nantong 226019, China
- State Environmental Protection Scientific Observation and Research Station for Ecological Environment of Lake Hulun Wetland, Hulunbuir 021000, China
| | - Guojian Ge
- School of Geographic Science, Nantong University, Nantong 226019, China
- State Environmental Protection Scientific Observation and Research Station for Ecological Environment of Lake Hulun Wetland, Hulunbuir 021000, China
| | - Yang Xu
- School of Geographic Science, Nantong University, Nantong 226019, China
- State Environmental Protection Scientific Observation and Research Station for Ecological Environment of Lake Hulun Wetland, Hulunbuir 021000, China
| | - Can Wang
- School of Geographic Science, Nantong University, Nantong 226019, China
- State Environmental Protection Scientific Observation and Research Station for Ecological Environment of Lake Hulun Wetland, Hulunbuir 021000, China
| | - Anyong Hu
- School of Geographic Science, Nantong University, Nantong 226019, China
- State Environmental Protection Scientific Observation and Research Station for Ecological Environment of Lake Hulun Wetland, Hulunbuir 021000, China
| | - Yujie Han
- School of Geographic Science, Nantong University, Nantong 226019, China
- State Environmental Protection Scientific Observation and Research Station for Ecological Environment of Lake Hulun Wetland, Hulunbuir 021000, China
| | - Nan Shan
- Nanjing Institute of Environmental Sciences, Ministry of Environmental Protection, Nanjing 210042, China
- State Environmental Protection Scientific Observation and Research Station for Ecological Environment of Lake Hulun Wetland, Hulunbuir 021000, China
| | - Bo Liu
- School of Geographic Science, Nantong University, Nantong 226019, China
- State Environmental Protection Scientific Observation and Research Station for Ecological Environment of Lake Hulun Wetland, Hulunbuir 021000, China
| | - Jinlin Chen
- Co-Innovation Center for Sustainable Forestry in Southern China, Nanjing Forestry University, Nanjing 210037, China
| | - Wenlin Wang
- Nanjing Institute of Environmental Sciences, Ministry of Environmental Protection, Nanjing 210042, China
- State Environmental Protection Scientific Observation and Research Station for Ecological Environment of Lake Hulun Wetland, Hulunbuir 021000, China
| |
Collapse
|
14
|
Štiglić J, Ujević Bošnjak M, Héry M, Kurajica L, Kinsela AS, Casiot C, Capak K. Bacterial diversity across four drinking water distribution systems in Croatia: impacts of water management practices and disinfection by-products. FEMS Microbiol Ecol 2022; 99:fiac146. [PMID: 36473705 DOI: 10.1093/femsec/fiac146] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/17/2024] Open
Abstract
Several factors may impact bacterial diversity in drinking water distribution systems (DWDSs) including the origin of the raw water, the water treatment technologies, and the disinfection practices applied. 16S rRNA metabarcoding was used for the in-depth characterization of bacterial communities in the four studied Croatian DWDSs (A, B, C, D) two of which had residual disinfectant (A, B) and two were without (C, D), while only B utilized the conventional water treatment technology. Significantly higher diversity and species richness were evidenced in non-disinfected DWDSs (p<0.05) compared to disinfected DWDSs. The phylum Proteobacteria was the most abundant in all the DWDSs, being proportionately higher in non-disinfected systems (p<0.05). The most abundant genera in DWDS-A Mycobacterium and Sphingomonas both positively correlated, whereas Lactobacillus negatively correlated with the concentration of disinfection by-products (DBPs) as a sum of haloacetic acids (HAAs). Conversely, the genus Ralstonia positively correlated with the individual DBP dichloroacetic acid. These results indicate that genera Sphingomonas, Mycobacterium, Lactobacillus and Ralstonia could have an effect on promoting the formation of DBPs, in a similar manner to how negatively correlated taxa may influence their degradation.
Collapse
Affiliation(s)
- J Štiglić
- Croatian Institute of Public Health, Rockefellerova 7, 10000 Zagreb, Croatia
| | - M Ujević Bošnjak
- Croatian Institute of Public Health, Rockefellerova 7, 10000 Zagreb, Croatia
| | - M Héry
- HydroSciences Montpellier, University of Montpellier, CNRS, IRD, Montpellier, France
| | - L Kurajica
- Croatian Institute of Public Health, Rockefellerova 7, 10000 Zagreb, Croatia
| | - A S Kinsela
- Water Research Centre, School of Civil and Environmental Engineering, University of New South Wales, Sydney, NSW 2052, Australia
| | - C Casiot
- HydroSciences Montpellier, University of Montpellier, CNRS, IRD, Montpellier, France
| | - K Capak
- Croatian Institute of Public Health, Rockefellerova 7, 10000 Zagreb, Croatia
| |
Collapse
|
15
|
Lanrewaju AA, Enitan-Folami AM, Sabiu S, Edokpayi JN, Swalaha FM. Global public health implications of human exposure to viral contaminated water. Front Microbiol 2022; 13:981896. [PMID: 36110296 PMCID: PMC9468673 DOI: 10.3389/fmicb.2022.981896] [Citation(s) in RCA: 21] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Accepted: 08/05/2022] [Indexed: 01/08/2023] Open
Abstract
Enteric viruses are common waterborne pathogens found in environmental water bodies contaminated with either raw or partially treated sewage discharge. Examples of these viruses include adenovirus, rotavirus, noroviruses, and other caliciviruses and enteroviruses like coxsackievirus and polioviruses. They have been linked with gastroenteritis, while some enteric viruses have also been implicated in more severe infections such as encephalitis, meningitis, hepatitis (hepatitis A and E viruses), cancer (polyomavirus), and myocarditis (enteroviruses). Therefore, this review presents information on the occurrence of enteric viruses of public health importance, diseases associated with human exposure to enteric viruses, assessment of their presence in contaminated water, and their removal in water and wastewater sources. In order to prevent illnesses associated with human exposure to viral contaminated water, we suggest the regular viral monitoring of treated wastewater before discharging it into the environment. Furthermore, we highlight the need for more research to focus on the development of more holistic disinfection methods that will inactivate waterborne viruses in municipal wastewater discharges, as this is highly needed to curtail the public health effects of human exposure to contaminated water. Moreover, such a method must be devoid of disinfection by-products that have mutagenic and carcinogenic potential.
Collapse
Affiliation(s)
| | | | - Saheed Sabiu
- Department of Biotechnology and Food Science, Durban University of Technology, Durban, South Africa
| | - Joshua Nosa Edokpayi
- Water and Environmental Management Research Group, Engineering and Agriculture, University of Venda, Thohoyandou, South Africa
| | - Feroz Mahomed Swalaha
- Department of Biotechnology and Food Science, Durban University of Technology, Durban, South Africa
| |
Collapse
|
16
|
Wu WX, Li F, Yao BJ, Ding LG, Kan JL, Liu F, Zhao GY, Wang S, Dong YB. Synthesis of covalent organic frameworks via Kabachnik-Fields reaction for water treatment. JOURNAL OF HAZARDOUS MATERIALS 2022; 433:128831. [PMID: 35417807 DOI: 10.1016/j.jhazmat.2022.128831] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Revised: 03/26/2022] [Accepted: 03/30/2022] [Indexed: 06/14/2023]
Abstract
Providing safe and clean domestic water for people is currently one of the greatest worldwide issues. In this context, heavy metal ions and pathogenic microbes are the two major factors in water pollution. The conventional water treatment methods, however, are generally high-energy and high-resource consumptive. Herein, we report, the first of its kind, the room-temperature synthesis of α-aminophosphonate-linked COFs via three-component one-pot in situ Kabachnik-Fields reaction (KF-3CR). Due to the coexistent bioactive α-aminophosphonate and photosensitive porphyrin, the obtained APCOF-1 exhibits highly efficient solar-powered bactericidal and heavy metal ion removal abilities, which allows it to be a promising COF-based multifunctional material for water treatment in an energy- and resource-saving way. Specifically, by incorporating APCOF-1 (up to 50 wt%) with eco-friendly and low-cost chitosan, an APCOF-1 @chitosan aerogel-based helical setup is fabricated via a facile templated freeze-drying approach and it can be a continuous flow-through water purifier model to achieve scaled-up water treatment through adsorptive removal of heavy metal ions and sunlight-driven sterilization. We believe that this research not only can significantly enrich the synthetic methodology of COFs, but also will hopefully bring COFs one step closer to the practical application.
Collapse
Affiliation(s)
- Wen-Xiu Wu
- College of Chemistry, Chemical Engineering and Materials Science, Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong, Key Laboratory of Molecular and Nano Probes, Ministry of Education, Shandong Normal University, Wen hua Road 88, Jinan 250014, PR China
| | - Fei Li
- College of Chemistry, Chemical Engineering and Materials Science, Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong, Key Laboratory of Molecular and Nano Probes, Ministry of Education, Shandong Normal University, Wen hua Road 88, Jinan 250014, PR China
| | - Bing-Jian Yao
- College of Chemistry, Chemical Engineering and Materials Science, Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong, Key Laboratory of Molecular and Nano Probes, Ministry of Education, Shandong Normal University, Wen hua Road 88, Jinan 250014, PR China.
| | - Luo-Gang Ding
- College of Chemistry, Chemical Engineering and Materials Science, Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong, Key Laboratory of Molecular and Nano Probes, Ministry of Education, Shandong Normal University, Wen hua Road 88, Jinan 250014, PR China
| | - Jing-Lan Kan
- College of Chemistry, Chemical Engineering and Materials Science, Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong, Key Laboratory of Molecular and Nano Probes, Ministry of Education, Shandong Normal University, Wen hua Road 88, Jinan 250014, PR China
| | - Fei Liu
- College of Chemistry, Chemical Engineering and Materials Science, Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong, Key Laboratory of Molecular and Nano Probes, Ministry of Education, Shandong Normal University, Wen hua Road 88, Jinan 250014, PR China
| | - Guo-Yan Zhao
- College of Life Sciences, Shandong Normal University, Jinan 250014, PR China
| | - Song Wang
- College of Life Sciences, Shandong Normal University, Jinan 250014, PR China
| | - Yu-Bin Dong
- College of Chemistry, Chemical Engineering and Materials Science, Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong, Key Laboratory of Molecular and Nano Probes, Ministry of Education, Shandong Normal University, Wen hua Road 88, Jinan 250014, PR China.
| |
Collapse
|
17
|
Lane K, Gagnon G. Comparing quantitative probability of occurrence to a risk matrix approach: A study of chlorine residual data. WATER RESEARCH 2022; 218:118480. [PMID: 35512534 DOI: 10.1016/j.watres.2022.118480] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/03/2021] [Revised: 03/03/2022] [Accepted: 04/18/2022] [Indexed: 06/14/2023]
Abstract
Implementation of water safety planning methods globally has focused primarily on developing an evidence base to demonstrate the benefits of the WSP methodology for risk management in water systems. However, little work has been completed to understand the appropriateness of the risk matrix method currently used to capture levels of risk for system-specific hazardous events. This study examines two quantitative risk calculations (probability density functions and event trees) compared to the risk matrix method employed in water safety planning. This analysis was undertaken to understand if the risk matrix provides an accurate estimation of risk in a water system. Two data sets were collected from nine water supply systems, both continuous inline monitoring and grab samples collected in water distribution systems (discrete events) for chlorine residual data. Using quantitative risk calculations, our study found the risk matrix does not accurately estimate risk compared to water quality data from a water system. In thirty-four (77%) of the forty-four possible scenarios investigated, the risk matrix method provided an underestimation or overestimation compared to the probability calculated using water quality data. The probabilities calculated using continuous data and the event tree method provided the closest estimations to the risk matrix, indicating larger data sets with simpler methods may be more likely to match WSP results. The lack of accuracy obtained reveals the need for a re-evaluation of the risk matrix within a water safety plan (WSP), particularly for systems with data available to perform advanced risk analysis. The risk matrix method has been used historically for systems with little data; however, for water systems with advanced water quality monitoring, adding quantitative probability calculations to a water safety plan has the potential to increase accuracy of risk assessment in water safety planning.
Collapse
Affiliation(s)
- Kaycie Lane
- Environmental and Water Resource Engineering, Department of Civil and Environmental Engineering, University of Massachusetts Amherst, MA, USA.
| | - Graham Gagnon
- Centre for Water and Resource Studies, Dalhousie University, Halifax, NS, Canada
| |
Collapse
|
18
|
Levy N, Cravo Oliveira Hashiguchi T, Cecchini M. Food safety policies and their effectiveness to prevent foodborne diseases in catering establishments: A systematic review and meta-analysis. Food Res Int 2022; 156:111076. [DOI: 10.1016/j.foodres.2022.111076] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2021] [Revised: 02/23/2022] [Accepted: 02/25/2022] [Indexed: 11/26/2022]
|
19
|
Matta G, Kumar P, Uniyal DP, Joshi DU. Communicating Water, Sanitation, and Hygiene under Sustainable Development Goals 3, 4, and 6 as the Panacea for Epidemics and Pandemics Referencing the Succession of COVID-19 Surges. ACS ES&T WATER 2022; 2:667-689. [PMID: 35603040 PMCID: PMC9113005 DOI: 10.1021/acsestwater.1c00366] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2021] [Revised: 04/13/2022] [Accepted: 04/14/2022] [Indexed: 05/25/2023]
Abstract
WASH (water, sanitation, and hygiene) has become the most crucial amenity in the past decade for every individual on the planet. In the UN agenda for 2030, which created 17 Sustainable Development Goals (SDGs), SDGs 3, 4, and 6 directly correlate with WASH practices and management for creating a good health hygiene environment for all. The dearth of WASH facilities has created barriers for averting the transmission of COVID-19, motivating the concept of WASH as the primary step of precaution and prevention, which includes WASH practices, communication for literacy, and positive behavioral changes primarily in developing and low-income countries. This Review deals with the complex concept of correlation of WASH and SDGs 3, 4, and 6 while defining elaborate WASH practices, including the prominence of clean water, the need for sanitation facilities, and health hygiene for good health and immunity for preparedness for and during epidemics and pandemics. Certain risk factors explain the sectors in which the gaps exist, creating a gap for implementation of WASH practices in epidemics and pandemics across the globe. Further, COVID-19 surge succession is presented along with data of different variants that have occurred. The need of WASH understanding is required using different tools (audio-visual, social media, print media, and mass media) and strategies (communication, advocacy, and positive behavioral changes) for every individual as an act to counter consequences during and after the COVID-19 pandemic and as a routine practice for future preparedness. This Review gives a detailed concept of WASH understanding for every sector from community to government agencies and research professionals to act immediately for the sustainable future of humanity.
Collapse
Affiliation(s)
- Gagan Matta
- Hydrological
Research Laboratory, Department of Zoology and Environmental Science, Gurukula Kangri (Deemed to be University), Haridwar 249404, India
| | - Pamposh Kumar
- National
Council for Science and Technology Communication, Department of Science
and Technology, Government of India, New Delhi 110016, India
| | - D. P. Uniyal
- Uttarakhand
State Council for Science and Technology, Dehradun 248007, India
| | - Divya U. Joshi
- Human
Resource Development Center, Kumaon University, Nainital 263002, India
| |
Collapse
|
20
|
Guo Y, Sivakumar M, Jiang G. Decay of four enteric pathogens and implications to wastewater-based epidemiology: Effects of temperature and wastewater dilutions. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 819:152000. [PMID: 34843787 DOI: 10.1016/j.scitotenv.2021.152000] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/19/2021] [Revised: 11/22/2021] [Accepted: 11/23/2021] [Indexed: 06/13/2023]
Abstract
Measurement of pathogens in raw wastewater from a population within certain sewer catchments can provide quantitative information on public health status within the sampled urban area. This so-called wastewater-based epidemiology (WBE) approach has the potential of becoming a powerful tool to monitor pathogen circulation and support timely intervention during outbreaks. However, many WBE studies failed to account for the pathogen decay during wastewater transportation in back calculating the disease prevalence. Various sewer process factors, including water temperature and infiltration/inflow, can lead to the variation of pathogen decay rates. This paper firstly reviewed the effects of temperature and types of water, i.e., wastewater, freshwater, and saline water, on the decay of four selected enteric pathogens, i.e., Campylobacter, Salmonella, Norovirus, and Adenovirus. To elucidate the importance of the pathogen decay rates (measured by culture and molecular methods) to WBE, a sensitivity analysis was conducted on the back-calculation equation for infection prevalence with decay rates collected from published literature. It was found that WBE back-calculation is more sensitive to decay rates under the condition of high wastewater temperature (i.e., over 25 °C) or if wastewater is diluted by saline water (i.e., sewer infiltration or use of seawater as an alternative source of freshwater constituting around 1/3 household water demand in some cities). Stormwater dilution of domestic wastewater (i.e., sewer inflow might achieve 10 times volumetric dilution) was shown to play a role in increasing the sensitivity of WBE back-calculation to bacterial pathogens, but not viral pathogens. Hence, WBE back-calculation in real sewers should account for in-sewer decay of specific pathogen species under different wastewater temperatures and dilutions. Overall, this review contributes to a better understanding of pathogen decay in wastewater which can lead to improved accuracy of WBE back-calculation.
Collapse
Affiliation(s)
- Ying Guo
- School of Civil, Mining and Environmental Engineering, University of Wollongong, Wollongong, Australia
| | - Muttucumaru Sivakumar
- School of Civil, Mining and Environmental Engineering, University of Wollongong, Wollongong, Australia
| | - Guangming Jiang
- School of Civil, Mining and Environmental Engineering, University of Wollongong, Wollongong, Australia; Illawarra Health and Medical Research Institute (IHMRI), University of Wollongong, Wollongong, Australia.
| |
Collapse
|
21
|
Thom C, Smith CJ, Moore G, Weir P, Ijaz UZ. Microbiomes in drinking water treatment and distribution: A meta-analysis from source to tap. WATER RESEARCH 2022; 212:118106. [PMID: 35091225 DOI: 10.1016/j.watres.2022.118106] [Citation(s) in RCA: 20] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/20/2021] [Revised: 01/12/2022] [Accepted: 01/16/2022] [Indexed: 06/14/2023]
Abstract
A meta-analysis of existing and available Illumina 16S rRNA datasets from drinking water source, treatment and drinking water distribution systems (DWDS) were collated to compare changes in abundance and diversity throughout. Samples from bulk water and biofilm were used to assess principles governing microbial community assembly and the value of amplicon sequencing to water utilities. Individual phyla relationships were explored to identify competitive or synergistic factors governing DWDS microbiomes. The relative importance of stochasticity in the assembly of the DWDS microbiome was considered to identify the significance of source and treatment in determining communities in DWDS. Treatment of water significantly reduces overall species abundance and richness, with chlorination of water providing the most impact to individual taxa relationships. The assembly of microbial communities in the bulk water of the source, primary treatment process and DWDS is governed by more stochastic processes, as is the DWDS biofilm. DWDS biofilm is significantly different from bulk water in terms of local contribution to beta diversity, type and abundance of taxa present. Water immediately post chlorination has a more deterministic microbial assembly, highlighting the significance of this process in changing the microbiome, although elevated levels of stochasticity in DWDS samples suggest that this may not be the case at customer taps. 16S rRNA sequencing is becoming more routine, and may have several uses for water utilities, including: detection and risk assessment of potential pathogens such as those within the genera of Legionella and Mycobacterium; assessing the risk of nitrification in DWDS; providing improved indicators of process performance and monitoring for significant changes in the microbial community to detect contamination. Combining this with quantitative methods like flow cytometry will allow a greater depth of understanding of the DWDS microbiome.
Collapse
Affiliation(s)
- Claire Thom
- Infrastructure and Environment Research Division, James Watt School of Engineering, University of Glasgow, UK; Scottish Water, 6 Castle Drive Dunfermline, KY11 8GG, UK.
| | - Cindy J Smith
- Infrastructure and Environment Research Division, James Watt School of Engineering, University of Glasgow, UK
| | - Graeme Moore
- Scottish Water, 6 Castle Drive Dunfermline, KY11 8GG, UK
| | - Paul Weir
- Scottish Water, 6 Castle Drive Dunfermline, KY11 8GG, UK
| | - Umer Z Ijaz
- Infrastructure and Environment Research Division, James Watt School of Engineering, University of Glasgow, UK
| |
Collapse
|
22
|
Zhang X, Lin T, Jiang F, Zhang X, Wang S, Zhang S. Impact of pipe material and chlorination on the biofilm structure and microbial communities. CHEMOSPHERE 2022; 289:133218. [PMID: 34890609 DOI: 10.1016/j.chemosphere.2021.133218] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/04/2021] [Revised: 12/04/2021] [Accepted: 12/06/2021] [Indexed: 06/13/2023]
Abstract
Pipe material and residual chlorine are key factors for the drinking water distribution system, and understanding the biofilm ecosystem is vital for water quality safeguard. The aim of our study was to determine the influence of pipe materials (ductile iron, steel, polyethylene) and chlorination on the biofilm structure and microbial community, as shown by the physicochemical properties, extracellular polymeric substances (EPS) structural characteristics, bacterial community composition, and functional traits. EPS spatial properties were studied based on a semi-quantitative confocal laser scanning microscope (CLSM) description. Regarding the impact of chlorination, residule chlorine (1.0 ± 0.3 mg L-1 free chlorine) could inhibit the bacteria colonization, and initiate a potential response to external disinfectants revealed by the EPS spatial distribution changes and communities variation compared to unchlorinated system. Regarding the impact of pipe material, polyethylene (PE) biofilms displayed lower biomass, loose zoogloea structure, lower proteins and polysaccharides content, and poor microbial diversity in contrast to ductile iron and steel biofilms. Pipe material was the more possible driving factor of the biofilm community composition compared to the chlorination based on principal coordinates analysis (PCoA) and permutational multivariate analysis of variance (PERMANOVA). Actinobacteria was dominant in the PE biofilms (45.57%-83.32%), while Alphaproteobacteria (34.30%-73.22%) and Gammaproteobacteria (6.46%-36.82%) were the major classes in the steel and ductile iron biofilms. The genus Rhodococcus was predominant in the PE biofilms. Rhodococcus, Pseudomonas, and Sphingomonas seemed to have a better growth advantage in the chlorinated system and display a stronger disinfectant resistance. Functional sketch prediction indicated the potential impact of pipe material and chlorination on functional pathway abundnce, possible functional pathways associated with infectious disease included. This study provides insights into the impact of pipe material and chlorination on biofilm structure and microbial community and might help to develop monitoring or maintenance strategies to protect the biosafety of the drinking water.
Collapse
Affiliation(s)
- Xinyue Zhang
- Ministry of Education Key Laboratory of Integrated Regulation and Resource Development on Shallow Lakes, Hohai University, Nanjing, 210098, PR China; College of Environment, Hohai University, Nanjing, 210098, PR China
| | - Tao Lin
- Ministry of Education Key Laboratory of Integrated Regulation and Resource Development on Shallow Lakes, Hohai University, Nanjing, 210098, PR China; College of Environment, Hohai University, Nanjing, 210098, PR China.
| | - Fuchun Jiang
- Suzhou Water Supply Company Limited, Suzhou, 215002, PR China
| | - Xue Zhang
- Suzhou Water Supply Company Limited, Suzhou, 215002, PR China
| | - Shiyu Wang
- Ministry of Education Key Laboratory of Integrated Regulation and Resource Development on Shallow Lakes, Hohai University, Nanjing, 210098, PR China; College of Environment, Hohai University, Nanjing, 210098, PR China
| | - Shisheng Zhang
- Ministry of Education Key Laboratory of Integrated Regulation and Resource Development on Shallow Lakes, Hohai University, Nanjing, 210098, PR China; College of Environment, Hohai University, Nanjing, 210098, PR China
| |
Collapse
|
23
|
Shubo T, Maranhão AG, Ferreira FC, de Silva E Mouta Júnior S, de Pedrosa Macena LDG, do Rosário Vaz Morgado C, Warish A, Sidhu JPS, Miagostovich MP. Microbiological characterization of stormwater in a high-income neighborhood in Rio de Janeiro, Brazil. ENVIRONMENTAL MONITORING AND ASSESSMENT 2022; 194:51. [PMID: 34985601 DOI: 10.1007/s10661-021-09677-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/12/2021] [Accepted: 12/06/2021] [Indexed: 06/14/2023]
Abstract
Stormwater harvesting and reuse in the urban environment is emerging as an alternative water source, despite human pathogens in the stormwater may represent a hazard to public health. This study presents the results of 1-year monitoring to evaluate the quality of stormwater obtained in a high-income neighborhood in Rio de Janeiro for a set of microbiological parameters as total coliforms, Escherichia coli (E. coli), human adenovirus (HAdV), human JC polyomavirus (JCPyV), Group A rotavirus (RVA), and norovirus GI and GII. Forty-eight stormwater samples obtained from two multiplex units presented total coliforms and E. coli in 91.7% (n = 44) and 58.3% (n = 28) of samples, while HAdV and JCPyV were detected in 20.8% (n = 10) and 12.5% (n = 6), respectively. Viral quantification ranged from 103 to 104 genomic copies/liter (GC/L) for HAdV and from 101 to 104 GC/L for JCPyV. Neither RVA nor norovirus GI and GII was detected. Fifteen out of sixteen (93.8%) samples containing viruses were compliant as per fecal indicator bacteria (FIB) according to Brazilian standards for rainwater reuse and US EPA Guidelines for Water Reuse, suggesting that viruses monitoring should complement the study of bacterial indicators.
Collapse
Affiliation(s)
- Tatsuo Shubo
- Environmental Engineering Program (PEA), Federal University of Rio de Janeiro, Rio de Janeiro, RJ, Brazil.
- Fundação Oswaldo Cruz, Av. Brazil, 4365, Manguinhos, Rio de Janeiro, RJ, 21040-360, Brazil.
| | - Adriana Gonçalves Maranhão
- Laboratory of Comparative and Environmental Virology, Oswaldo Cruz Institute (IOC), Oswaldo Cruz Foundation (FIOCRUZ), Rio de Janeiro, RJ, Brazil
| | - Fernando César Ferreira
- Laboratory of Comparative and Environmental Virology, Oswaldo Cruz Institute (IOC), Oswaldo Cruz Foundation (FIOCRUZ), Rio de Janeiro, RJ, Brazil
| | - Sérgio de Silva E Mouta Júnior
- Laboratory of Comparative and Environmental Virology, Oswaldo Cruz Institute (IOC), Oswaldo Cruz Foundation (FIOCRUZ), Rio de Janeiro, RJ, Brazil
| | - Lorena da Graça de Pedrosa Macena
- Laboratory of Comparative and Environmental Virology, Oswaldo Cruz Institute (IOC), Oswaldo Cruz Foundation (FIOCRUZ), Rio de Janeiro, RJ, Brazil
| | | | - Ahmed Warish
- Environmental Contaminant Mitigation & Biotechnologies (ECMB), Commonwealth Scientific and Industrial Research Organization (CSIRO), Brisbane, QLD, Australia
| | - Jatinder P S Sidhu
- Ecoscience Precinct, CSIRO Oceans and Atmosphere, 41 Boggo Road, Brisbane, 4102, Australia
| | - Marize Pereira Miagostovich
- Laboratory of Comparative and Environmental Virology, Oswaldo Cruz Institute (IOC), Oswaldo Cruz Foundation (FIOCRUZ), Rio de Janeiro, RJ, Brazil
| |
Collapse
|
24
|
Patidar P, Prakash T. Decoding the roles of extremophilic microbes in the anaerobic environments: Past, Present, and Future. CURRENT RESEARCH IN MICROBIAL SCIENCES 2022; 3:100146. [PMID: 35909618 PMCID: PMC9325894 DOI: 10.1016/j.crmicr.2022.100146] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2021] [Revised: 06/11/2022] [Accepted: 06/13/2022] [Indexed: 12/03/2022] Open
Abstract
The inaccessible extreme environments harbor a large majority of anaerobic microbes which remain unknown. Anaerobic microbes are used in a variety of industrial applications. In the future, metagenomic-assisted techniques can be used to identify novel anaerobic microbes from the unexplored extreme environments. Genetic engineering can be used to enhance the efficiency of anaerobic microbes for various processes.
The genome of an organism is directly or indirectly correlated with its environment. Consequently, different microbes have evolved to survive and sustain themselves in a variety of environments, including unusual anaerobic environments. It is believed that their genetic material could have played an important role in the early evolution of their existence in the past. Presently, out of the uncountable number of microbes found in different ecosystems we have been able to discover only one percent of the total communities. A large majority of the microbial populations exists in the most unusual and extreme environments. For instance, many anaerobic bacteria are found in the gastrointestinal tract of humans, soil, and hydrothermal vents. The recent advancements in Metagenomics and Next Generation Sequencing technologies have improved the understanding of their roles in these environments. Presently, anaerobic bacteria are used in various industries associated with biofuels, fermentation, production of enzymes, vaccines, vitamins, and dairy products. This broad applicability brings focus to the significant contribution of their genomes in these functions. Although the anaerobic microbes have become an irreplaceable component of our lives, a major and important section of such anaerobic microbes still remain unexplored. Therefore, it can be said that unlocking the role of the microbial genomes of the anaerobes can be a noteworthy discovery not just for mankind but for the entire biosystem as well.
Collapse
Affiliation(s)
- Pratyusha Patidar
- School of Basic Sciences, Indian Institute of Technology (IIT) Mandi, HP, India
| | - Tulika Prakash
- School of Basic Sciences, Indian Institute of Technology (IIT) Mandi, HP, India
- Corresponding author.
| |
Collapse
|
25
|
Zohra T, Ikram A, Salman M, Amir A, Saeed A, Ashraf Z, Ahad A. Wastewater based environmental surveillance of toxigenic Vibrio cholerae in Pakistan. PLoS One 2021; 16:e0257414. [PMID: 34591885 PMCID: PMC8483414 DOI: 10.1371/journal.pone.0257414] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2021] [Accepted: 09/01/2021] [Indexed: 01/10/2023] Open
Abstract
BACKGROUND Pakistan has been experiencing intervals of sporadic cases and localized outbreaks in the last two decades. No proper study has been carried out in order to find out the environmental burden of toxigenic V. cholerae as well as how temporal and environmental factors associated in driving cholera across the country. METHODS We tested waste water samples from designated national environment surveillance sites in Pakistan with RT-PCR assay. Multistage sampling technique were utilized for samples collection and for effective sample processing Bag-Mediated Filtration system, were employed. Results were analysed by district and month wise to understand the geographic distribution and identify the seasonal pattern of V. cholera detection in Pakistan. RESULTS Between May 2019, and February 2020, we obtained and screened 160 samples in 12 districts across Pakistan. Out of 16 sentinel environmental surveillance sites, 15 sites showed positive results against cholera toxigenic gene with mostly lower CT value (mean, 34±2) and have significant difference (p < 0.05). The highest number of positive samples were collected from Sindh in month of November, then in June it is circulating in different districts of Pakistan including four Provinces respectively. CONCLUSION V. cholera detection do not follow a clear seasonal pattern. However, the poor sanitation problems or temperature and rainfall may potentially influence the frequency and duration of cholera across the country. Occurrence of toxigenic V. cholerae in the environment samples showed that cholera is endemic, which is an alarming for a potential future cholera outbreaks in the country.
Collapse
Affiliation(s)
- Tanzeel Zohra
- Public Health Laboratories Division, Department of Microbiology, National Institute of Health, Islamabad, Pakistan
| | - Aamer Ikram
- Public Health Laboratories Division, Department of Microbiology, National Institute of Health, Islamabad, Pakistan
| | - Muhammad Salman
- Public Health Laboratories Division, Department of Microbiology, National Institute of Health, Islamabad, Pakistan
| | - Afreenish Amir
- Public Health Laboratories Division, Department of Microbiology, National Institute of Health, Islamabad, Pakistan
| | - Asim Saeed
- Public Health Laboratories Division, Department of Microbiology, National Institute of Health, Islamabad, Pakistan
| | - Zurva Ashraf
- Public Health Laboratories Division, Department of Microbiology, National Institute of Health, Islamabad, Pakistan
| | - Abdul Ahad
- Public Health Laboratories Division, Department of Microbiology, National Institute of Health, Islamabad, Pakistan
| |
Collapse
|
26
|
Simões J, Yang Z, Dong T. An ultrasensitive fluorimetric sensor for pre-screening of water microbial contamination risk. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2021; 258:119805. [PMID: 33957453 DOI: 10.1016/j.saa.2021.119805] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/13/2020] [Revised: 03/21/2021] [Accepted: 04/06/2021] [Indexed: 06/12/2023]
Abstract
In recent years, global efforts have been directed towards the development of water safety routines, consequently demanding cost-effective sensors capable of detecting outbreaks at early stages. This work reports the development and study of an original in-field tryptophan fluorimetric sensor as a potential indicator of real-time microbial contamination in water. The sensor excitation and emission wavelengths were selected with respect to the coliform bacteria tryptophan peak; 280 nm for excitation and 330 nm for emission. The in-lab tests with standard samples show a detection limit of 4.89 nM (≈0.1 μg/l) for L-tryptophan. The sensor exhibited good linearity over three orders of magnitude and considerable detection reproducibility, which was confirmed during calibration tests. Small-scale in situ tests showed that the sensor was better correlated with coliform bacteria than other online sensors such as turbidity. This suggests that the fluorimetric tryptophan sensor can be integrated into early warning systems that quickly assess changes in water microbial quality.
Collapse
Affiliation(s)
- João Simões
- Department of Microsystems-IMS, Faculty of Technology, Natural Sciences and Maritime Sciences, University of South-Eastern Norway-USN, P.O. Box 235, Kongsberg 3603, Norway
| | - Zhaochu Yang
- Chongqing Key Laboratory of Micro-Nano Systems and Intelligent Transduction, Collaborative Innovation Center on Micro-Nano Transduction and Intelligent Eco-Internet of Things, Chongqing Municipal Key Laboratory of Institutions of Higher Education on Micro-Nano Systems Technology and Smart Transducing, National Research Base of Intelligent Manufacturing Service, Chongqing Technology and Business University, Chongqing 400067, China
| | - Tao Dong
- Department of Microsystems-IMS, Faculty of Technology, Natural Sciences and Maritime Sciences, University of South-Eastern Norway-USN, P.O. Box 235, Kongsberg 3603, Norway.
| |
Collapse
|
27
|
Taviani E, Pedro O. Impact of the aquatic pathobiome in low-income and middle-income countries (LMICs) quest for safe water and sanitation practices. Curr Opin Biotechnol 2021; 73:220-224. [PMID: 34492621 DOI: 10.1016/j.copbio.2021.08.015] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2021] [Revised: 08/10/2021] [Accepted: 08/18/2021] [Indexed: 11/03/2022]
Abstract
Microbial contamination of surface waters is of particular relevance in low-income and middle-income countries (LMICs) since they often represent the only available source of water for drinking and domestic use. In the recent years, a growing urbanization, profound demographic shifts and drastic climate events have greatly affected LMICs capacity to reach access to safe drinking water and sanitation practices, and to protect citizens' health from risks associated to the exposure and use of contaminated water. Detailed phylogenetic and microbiological information on the exact composition of pathogenic organisms in urban and peri-urban water is scarce, especially in rapidly changing settings of sub-Saharan Africa. In this review we aim to highlight how large-scale water pathobiome studies can support the LMICs challenge to global access to safe water and sanitation practices.
Collapse
Affiliation(s)
- Elisa Taviani
- Center for Biotechnology, University Eduardo Mondlane, Maputo, Mozambique.
| | - Olivia Pedro
- Center for Biotechnology, University Eduardo Mondlane, Maputo, Mozambique
| |
Collapse
|
28
|
Reynolds LJ, Martin NA, Sala-Comorera L, Callanan K, Doyle P, O'Leary C, Buggy P, Nolan TM, O'Hare GMP, O'Sullivan JJ, Meijer WG. Identifying Sources of Faecal Contamination in a Small Urban Stream Catchment: A Multiparametric Approach. Front Microbiol 2021; 12:661954. [PMID: 34267734 PMCID: PMC8276237 DOI: 10.3389/fmicb.2021.661954] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2021] [Accepted: 05/24/2021] [Indexed: 01/15/2023] Open
Abstract
Small urban streams discharging in the proximity of bathing waters may significantly contribute to the deterioration of water quality, yet their impact may be overlooked. This study focuses on the Elm Park stream in the city of Dublin that is subject to faecal contamination by unidentified sources. The aim of the study was to identify a minimum number of “sentinel” sampling stations in an urban catchment that would provide the maximum amount of information regarding faecal pollution in the catchment. Thus, high-resolution sampling within the catchment was carried out over the course of 1 year at 11 stations. Faecal indicator bacteria were enumerated and microbial source tracking (MST) was employed to evaluate human pollution. In addition, ammonium, total oxidised nitrogen, and phosphorus levels were monitored to determine if these correlated with faecal indicator and the HF183 MST marker. In addition, the effect of severe weather events on water quality was assessed using automated sampling at one of the identified “sentinel” stations during baseflow and high flow conditions over a 24-h period. Our results show that this urban stream is at times highly contaminated by point source faecal pollution and that human faecal pollution is pervasive in the catchment. Correlations between ammonium concentrations and faecal indicator bacteria (FIB) as well as the human MST marker were observed during the study. Cluster analysis identified four “sentinel” stations that provide sufficient information on faecal pollution in the stream, thus reducing the geographical complexity of the catchment. Furthermore, ammonium levels strongly correlated with FIB and the human HF183 MST marker under high flow conditions at key “sentinel” stations. This work demonstrates the effectiveness of pairing MST, faecal indicators, and ammonium monitoring to identify “sentinel” stations that could be more rapidly assessed using real-time ammonium readouts to assess remediation efforts.
Collapse
Affiliation(s)
- Liam J Reynolds
- UCD School of Biomolecular and Biomedical Science, UCD Earth Institute, and UCD Conway Institute, University College Dublin, Dublin, Ireland
| | - Niamh A Martin
- UCD School of Biomolecular and Biomedical Science, UCD Earth Institute, and UCD Conway Institute, University College Dublin, Dublin, Ireland
| | - Laura Sala-Comorera
- UCD School of Biomolecular and Biomedical Science, UCD Earth Institute, and UCD Conway Institute, University College Dublin, Dublin, Ireland
| | - Kevin Callanan
- Central Laboratory, Dublin City Council, Dublin, Ireland
| | - Padraig Doyle
- Drainage Planning, Policy and Development Control, Dublin City Council, Dublin, Ireland
| | - Clare O'Leary
- Central Laboratory, Dublin City Council, Dublin, Ireland
| | - Paul Buggy
- Municipal Services, Dún Laoghaire-Rathdown County Council, Dublin, Ireland
| | - Tristan M Nolan
- UCD School of Biomolecular and Biomedical Science, UCD Earth Institute, and UCD Conway Institute, University College Dublin, Dublin, Ireland
| | - Gregory M P O'Hare
- UCD School of Computer Science, UCD Earth Institute, University College Dublin, Dublin, Ireland
| | - John J O'Sullivan
- UCD School of Civil Engineering, UCD Dooge Centre for Water Resources Research, UCD Earth Institute, University College Dublin, Dublin, Ireland
| | - Wim G Meijer
- UCD School of Biomolecular and Biomedical Science, UCD Earth Institute, and UCD Conway Institute, University College Dublin, Dublin, Ireland
| |
Collapse
|
29
|
Bartolomeu M, Oliveira C, Pereira C, Neves MGPMS, Faustino MAF, Almeida A. Antimicrobial Photodynamic Approach in the Inactivation of Viruses in Wastewater: Influence of Alternative Adjuvants. Antibiotics (Basel) 2021; 10:767. [PMID: 34202496 PMCID: PMC8300698 DOI: 10.3390/antibiotics10070767] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2021] [Revised: 06/19/2021] [Accepted: 06/21/2021] [Indexed: 11/24/2022] Open
Abstract
Pathogenic viruses are frequently present in marine and estuarine waters, due to poor wastewater (WW) treatments, which consequently affect water quality and human health. Chlorination, one of the most common methods used to ensure microbiological safety in tertiarily treated effluents, may lead to the formation of toxic chemical disinfection by-products on reaction with organic matter present in the effluents. Antimicrobial photodynamic therapy (aPDT) can be a promising disinfecting approach for the inactivation of pathogens, without the formation of known toxic by-products. Additionally, some studies have reported the potentiator effect on aPDT of some compounds, such as potassium iodide (KI) and hydrogen peroxide (H2O2). In the present study, the aPDT efficiency of a PS formulation constituted of five cationic porphyrins (Form) in the inactivation of E. coli T4-like bacteriophage, a model of mammalian viruses, in different aqueous matrices with different organic matter content, was evaluated. Photoinactivation studies were performed at different concentrations of Form and in the presence of the adjuvants KI and H2O2. The results showed that the efficiency of bacteriophage photoinactivation is correlated with the Form concentration, the amount of the organic matter in WW, and the adjuvant type. Form can be an effective alternative to controlling viruses in WW, particularly if combined with H2O2, allowing to significantly reduce PS concentration and treatment time. When combined with KI, the Form is less effective in inactivating T4-like bacteriophage in WW.
Collapse
Affiliation(s)
- Maria Bartolomeu
- Department of Biology and CESAM, University of Aveiro, 3810-193 Aveiro, Portugal; (M.B.); (C.O.); (C.P.)
| | - Cristiana Oliveira
- Department of Biology and CESAM, University of Aveiro, 3810-193 Aveiro, Portugal; (M.B.); (C.O.); (C.P.)
| | - Carla Pereira
- Department of Biology and CESAM, University of Aveiro, 3810-193 Aveiro, Portugal; (M.B.); (C.O.); (C.P.)
| | | | - M. Amparo F. Faustino
- Department of Chemistry and LAQV-REQUIMTE, University of Aveiro, 3810-193 Aveiro, Portugal;
| | - Adelaide Almeida
- Department of Biology and CESAM, University of Aveiro, 3810-193 Aveiro, Portugal; (M.B.); (C.O.); (C.P.)
| |
Collapse
|
30
|
Mraz AL, Tumwebaze IK, McLoughlin SR, McCarthy ME, Verbyla ME, Hofstra N, Rose JB, Murphy HM. Why pathogens matter for meeting the united nations' sustainable development goal 6 on safely managed water and sanitation. WATER RESEARCH 2021; 189:116591. [PMID: 33189973 PMCID: PMC7814340 DOI: 10.1016/j.watres.2020.116591] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/10/2020] [Revised: 10/26/2020] [Accepted: 11/01/2020] [Indexed: 05/14/2023]
Abstract
Water and wastewater utilities, water and sanitation hygiene (WASH) practitioners, and regulating bodies, particularly in developing nations, rely heavily on indicator microorganisms, as opposed to pathogens, for much of their regulatory decisions. This commentary illustrates the importance of considering pathogens and not relying only on indicator organisms when making decisions regarding water and sanitation, especially with respect to meeting the current targets of the Sustainable Development Goal (SDG) 6. We use quantitative microbial risk assessment (QMRA) to present three common scenarios that WASH and public health practitioners encounter to illustrate our point. These include 1) chlorination of surface water for drinking, 2) land application of latrine waste as a fertilizer, and 3) recreation/domestic use of surface waters impacted by wastewater discharge. We show that the calculated probabilities of risk of infection are statistically significantly higher when using treatment/survival information for pathogens versus using indicator species data. Thus, demonstrating that relying solely on indicators for sanitation decision making is inadequate if we truly want to achieve the SDG6 targets of safely managed water and sanitation services.
Collapse
Affiliation(s)
- Alexis L Mraz
- Water, Health and Applied Microbiology Lab (WHAM Lab), Philadelphia, PA USA; Department of Public Health, College of Health and Exercise Science, The College of New Jersey, Ewing, NJ USA; Department of Epidemiology and Biostatistics, College of Public Health, Temple University, Philadelphia, PA, USA
| | - Innocent K Tumwebaze
- Water, Health and Applied Microbiology Lab (WHAM Lab), Philadelphia, PA USA; Department of Epidemiology and Biostatistics, College of Public Health, Temple University, Philadelphia, PA, USA
| | - Shane R McLoughlin
- Water, Health and Applied Microbiology Lab (WHAM Lab), Philadelphia, PA USA; Department of Epidemiology and Biostatistics, College of Public Health, Temple University, Philadelphia, PA, USA
| | - Megan E McCarthy
- Water, Health and Applied Microbiology Lab (WHAM Lab), Philadelphia, PA USA; Department of Epidemiology and Biostatistics, College of Public Health, Temple University, Philadelphia, PA, USA
| | - Matthew E Verbyla
- Department of Civil, Construction, and Environmental Engineering, San Diego State University, San Diego, CA, USA
| | - Nynke Hofstra
- Water Systems and Global Change Group, Wageningen University & Research, Wageningen, the Netherlands
| | - Joan B Rose
- Department of Fisheries and Wildlife, Michigan State University, East Lansing, MI, USA
| | - Heather M Murphy
- Water, Health and Applied Microbiology Lab (WHAM Lab), Philadelphia, PA USA; Department of Epidemiology and Biostatistics, College of Public Health, Temple University, Philadelphia, PA, USA; Department of Pathobiology, Ontario Veterinary College, University of Guelph, Guelph, ON, Canada.
| |
Collapse
|
31
|
Water Lice and Other Macroinvertebrates in Drinking Water Pipes: Diversity, Abundance and Health Risk. WATER 2021. [DOI: 10.3390/w13030276] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Activities to ensure and maintain water quality in drinking water networks, including flushing, are presented after standardized hydrant sampling combined with a stainless-steel low pressure–high flow rate (NDHF) filter and a 100 µm mesh size was used to separate pipe inhabitants. A databank of more than 1000 hydrant samples in European lowland areas was developed and used to analyze the diversity and abundance of macroinvertebrates in drinking water networks. Load classes for water louse (Asellus aquaticus) and oligochaetes are given with three evaluation classes: normal colonization, increased colonization, and mass development. The response of Asellus aquaticus in drinking water networks to environmental conditions are presented as are their growth and reproduction, promotion of a third generation by climate change effects, food limitations, and the composition and stability of their feces. Finally, the health risks posed by dead water lice and water lice feces with bacterial regrowth and the promotion of microbe development on house filters are analyzed.
Collapse
|
32
|
Potgieter N, Banda NT, Becker PJ, Traore-Hoffman AN. WASH infrastructure and practices in primary health care clinics in the rural Vhembe District municipality in South Africa. BMC FAMILY PRACTICE 2021; 22:8. [PMID: 33397298 PMCID: PMC7780685 DOI: 10.1186/s12875-020-01346-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/19/2020] [Accepted: 12/07/2020] [Indexed: 11/10/2022]
Abstract
BACKGROUND South Africa has unique and diverse social and economic factors that have an impact on the provision of basic water, sanitation, hygiene and waste management infrastructure and practices at health care facilities in ensuring patient safety and prevent the spread of diseases. METHODS The aim of this study was to evaluate water, sanitation and hygiene access and standards at 50 government owned public health care clinics in the rural region of the Vhembe district of South Africa during 2016/2017, using self-observation, an observation checklist, record reviews and interviews with clinic managers. Water quality from all available water sources on the clinic compound was analysed for Total coliform and E. coli counts using the Colilert Quanti-tray/2000 system. The prevalence of pathogenic diarrhea causing E. coli strains was established using multiplex-Polymerase Chain Reaction. RESULTS The health care clinics in the Vhembe District generally complied with the basic WASH services guidelines according to the World Health Organisation. Although 80% of the clinics used borehole water which is classified as an improved water source, microbiological assessment showed that 38% inside taps and 64% outside taps from the clinic compounds had TC counts higher than guideline limits for safe drinking. Similarly, EC counts above the guideline limit for safe drinking water were detected in 17% inside taps and 32% outside taps from the clinic compounds. Pathogenic EAEC, EPEC, ETEC and EHEC strains were isolated in the collected water samples. Although improved sanitation infrastructures were present in most of the clinics, the sanitary conditions of these toilets were not up to standard. Waste systems were not adequately managed. A total of 90% of the clinics had hand washing basins, while only 61% of the clinics had soap present and only 64% of the clinics had adequate signs and posters reminding the staff, care givers and patients to wash their hands. CONCLUSIONS Various WASH aspects within the primary health care system in South Africa needs to be improved and corrected. A more rigorous system that is inclusive of all role players in the WASH sectors, with regular monitoring and training sessions, should be used.
Collapse
Affiliation(s)
- N Potgieter
- Department of Microbiology, University of Venda, Thohoyandou, South Africa.
| | - N T Banda
- Department of Microbiology, University of Venda, Thohoyandou, South Africa
| | - P J Becker
- Research Office, Faculty of Health Sciences, University of Pretoria, Pretoria, South Africa
| | - A N Traore-Hoffman
- Department of Microbiology, University of Venda, Thohoyandou, South Africa
| |
Collapse
|
33
|
Pascual-Benito M, Emiliano P, Casas-Mangas R, Dacal-Rodríguez C, Gracenea M, Araujo R, Valero F, García-Aljaro C, Lucena F. Assessment of dead-end ultrafiltration for the detection and quantification of microbial indicators and pathogens in the drinking water treatment processes. Int J Hyg Environ Health 2020; 230:113628. [PMID: 33038613 DOI: 10.1016/j.ijheh.2020.113628] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2020] [Revised: 09/05/2020] [Accepted: 09/07/2020] [Indexed: 10/23/2022]
Abstract
A safe water supply requires distinct treatments and monitoring to guarantee the absence of pathogens and substances potentially hazardous for human health. In this study we assessed the efficiency of the dead-end ultrafiltration (DEUF) method to concentrate faecal indicator organisms (FIO) and pathogens in water samples with different physicochemical characteristics. Water samples were collected at the treatment stages of two drinking water treatment plants to analyse the concentration of a variety of 7 FIO and 4 reference microbes which have some species that are pathogenic to humans: Campylobacter spp., enteroviruses, Cryptosporidium spp. and Giardia spp. The samples were analysed before and after concentration by DEUF, detecting FIO concentrations about 1 log10 higher in non-concentrated samples from both catchments. Percent recoveries were highly variable with a mean of 43.8 ± 17.5%, depending on the FIO and inherent sample characteristics. However, DEUF enabled FIO concentration in high volumes of water (100-500 l), allowing a reduction in the detection limit compared to the non-concentrated samples due to the high volume processing capabilities of the method. As a consequence, the detection of FIO removal from water in the drinking water treatment process was 1.0-1.5 logarithms greater in DEUF-treated water compared to unfiltered samples. The DEUF method improved the detection of target indicators and allowed for the detection of pathogens in low concentrations in water after the treatment stages, confirming the suitability of DEUF to concentrate high volumes of different types of water. This method could be useful for microbial analysis in water treatment monitoring and risk assessment, allowing the identification of critical points during the water treatment process and potential hazards in water destined for several uses.
Collapse
Affiliation(s)
- Miriam Pascual-Benito
- Department of Genetics, Microbiology and Statistics, Faculty of Biology, University of Barcelona, Diagonal 643, 08028, Barcelona, Spain; The Water Research Institute, University of Barcelona, Montalegre 6, 08001, Barcelona, Spain.
| | - Pere Emiliano
- Ens d'Abastament d'Aigua Ter Llobregat (ATL), Sant Martí de l'Erm, 30, 08970, Sant Joan Despí, Barcelona
| | - Raquel Casas-Mangas
- Department of Genetics, Microbiology and Statistics, Faculty of Biology, University of Barcelona, Diagonal 643, 08028, Barcelona, Spain; The Water Research Institute, University of Barcelona, Montalegre 6, 08001, Barcelona, Spain
| | - Cristina Dacal-Rodríguez
- The Water Research Institute, University of Barcelona, Montalegre 6, 08001, Barcelona, Spain; Department of Biology, Healthcare and the Environment, Faculty of Pharmacy, University of Barcelona, Joan XXIII 27-31, 08028, Spain
| | - Mercedes Gracenea
- The Water Research Institute, University of Barcelona, Montalegre 6, 08001, Barcelona, Spain; Department of Biology, Healthcare and the Environment, Faculty of Pharmacy, University of Barcelona, Joan XXIII 27-31, 08028, Spain
| | - Rosa Araujo
- Department of Genetics, Microbiology and Statistics, Faculty of Biology, University of Barcelona, Diagonal 643, 08028, Barcelona, Spain; The Water Research Institute, University of Barcelona, Montalegre 6, 08001, Barcelona, Spain
| | - Fernando Valero
- Ens d'Abastament d'Aigua Ter Llobregat (ATL), Sant Martí de l'Erm, 30, 08970, Sant Joan Despí, Barcelona
| | - Cristina García-Aljaro
- Department of Genetics, Microbiology and Statistics, Faculty of Biology, University of Barcelona, Diagonal 643, 08028, Barcelona, Spain; The Water Research Institute, University of Barcelona, Montalegre 6, 08001, Barcelona, Spain
| | - Francisco Lucena
- Department of Genetics, Microbiology and Statistics, Faculty of Biology, University of Barcelona, Diagonal 643, 08028, Barcelona, Spain; The Water Research Institute, University of Barcelona, Montalegre 6, 08001, Barcelona, Spain
| |
Collapse
|
34
|
Paruch L, Paruch AM, Eiken HG, Skogen M, Sørheim R. Seasonal dynamics of lotic bacterial communities assessed by 16S rRNA gene amplicon deep sequencing. Sci Rep 2020; 10:16399. [PMID: 33009479 PMCID: PMC7532223 DOI: 10.1038/s41598-020-73293-9] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2020] [Accepted: 09/15/2020] [Indexed: 12/04/2022] Open
Abstract
Aquatic microbial diversity, composition, and dynamics play vital roles in sustaining water ecosystem functionality. Yet, there is still limited knowledge on bacterial seasonal dynamics in lotic environments. This study explores a temporal pattern of bacterial community structures in lotic freshwater over a 2-year period. The aquatic bacterial communities were assessed using Illumina MiSeq sequencing of 16S rRNA genes. Overall, the communities were dominated by α-, β-, and γ-Proteobacteria, Bacteroidetes, Flavobacteriia, and Sphingobacteriia. The bacterial compositions varied substantially in response to seasonal changes (cold vs. warm), but they were rather stable within the same season. Furthermore, higher diversity was observed in cold seasons compared to warm periods. The combined seasonal-environmental impact of different physico-chemical parameters was assessed statistically, and temperature, suspended solids, and nitrogen were determined to be the primary abiotic factors shaping the temporal bacterial assemblages. This study enriches particular knowledge on the seasonal succession of the lotic freshwater bacteria.
Collapse
Affiliation(s)
- Lisa Paruch
- Division of Environment and Natural Resources, Norwegian Institute of Bioeconomy Research - NIBIO, Oluf Thesens vei 43, 1433, Ås, Norway
| | - Adam M Paruch
- Division of Environment and Natural Resources, Norwegian Institute of Bioeconomy Research - NIBIO, Oluf Thesens vei 43, 1433, Ås, Norway.
| | - Hans Geir Eiken
- Division of Environment and Natural Resources, Norwegian Institute of Bioeconomy Research - NIBIO, Oluf Thesens vei 43, 1433, Ås, Norway
| | - Monica Skogen
- Division of Biotechnology and Plant Health, Norwegian Institute of Bioeconomy Research - NIBIO, Høgskoleveien 7, 1433, Ås, Norway
| | - Roald Sørheim
- Division of Environment and Natural Resources, Norwegian Institute of Bioeconomy Research - NIBIO, Oluf Thesens vei 43, 1433, Ås, Norway
| |
Collapse
|
35
|
Teixeira P, Dias D, Costa S, Brown B, Silva S, Valério E. Bacteroides spp. and traditional fecal indicator bacteria in water quality assessment - An integrated approach for hydric resources management in urban centers. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2020; 271:110989. [PMID: 32579514 DOI: 10.1016/j.jenvman.2020.110989] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/21/2020] [Revised: 05/28/2020] [Accepted: 06/16/2020] [Indexed: 06/11/2023]
Abstract
As part of a sustainable water resources management, the Lisbon municipality identified groundwater and treated wastewater use increase as two opportunities for better and sustainable water use, with natural safeguard for public health as a priority. In this context, the aim of our research was to assess the suitability of the human-associated marker gene Bacteroides HF183 and the cattle feces-associated CowM2, in routine water quality monitoring as indicators for water use and reuse, providing a tool to more accurately assess public health risks. To this intent, Real-Time quantitative PCR was used for detection of human-associated marker gene Bacteroides HF183 and the bovine-associated CowM2, in a total of 67 samples - groundwater and wastewater at three different treatment stages of a Waste Water Treatment Plant, in Lisbon. HF183 marker gene was detected in treated and untreated wastewater samples, with significant concentration reductions from untreated (6,07 E+07 copies/mL) to secondary treated effluent (1,86 E+05 copies/mL) and a further decrease in tertiary treatment (5,74 E+04 copies/mL). In groundwater samples, this marker was also detected in concentrations ranging from 2,63 E+02 copies/mL to 2,24 E+03 copies/mL. CowM2 marker gene on the other hand was only detected in wastewater samples, with concentrations ranging from 2,47 E+02 copies/mL to 1,17 E+04 copies/mL. Our research indicates that the use of Bacteroides spp. in association with traditional fecal indicator bacteria (FIB) is advantageous for water managing entities in urban settings, such as Lisbon, were drainage system failures may occur. An integrated approach thus provides crucial and more adequate information towards mitigation and correction measures when fecal contamination is detected in environmental waters.
Collapse
Affiliation(s)
- Pedro Teixeira
- Câmara Municipal de Lisboa, Direcção Municipal Do Ambiente, Estrutura Verde, Clima e Energia, Laboratório de Bromatologia e Águas, Avenida Cidade Do Porto S/N, 1700-111, Lisboa, Portugal; Faculdade de Ciências da Universidade de Lisboa, Centro de Estudos Do Ambiente e Do Mar (CESAM Lisboa), Campo Grande, 1749-016, Lisboa, Portugal; Departamento de Saúde Ambiental, Instituto Nacional de Saúde Doutor Ricardo Jorge, Avenida Padre Cruz, 1649-016, Lisboa, Portugal.
| | - Deodália Dias
- Faculdade de Ciências da Universidade de Lisboa, Centro de Estudos Do Ambiente e Do Mar (CESAM Lisboa), Campo Grande, 1749-016, Lisboa, Portugal
| | - Sílvia Costa
- Câmara Municipal de Lisboa, Direcção Municipal Do Ambiente, Estrutura Verde, Clima e Energia, Laboratório de Bromatologia e Águas, Avenida Cidade Do Porto S/N, 1700-111, Lisboa, Portugal
| | - Bárbara Brown
- Câmara Municipal de Lisboa, Direcção Municipal Do Ambiente, Estrutura Verde, Clima e Energia, Laboratório de Bromatologia e Águas, Avenida Cidade Do Porto S/N, 1700-111, Lisboa, Portugal
| | - Susana Silva
- Departamento de Epidemiologia, Instituto Nacional de Saúde Doutor Ricardo Jorge, Avenida Padre Cruz, 1649-016, Lisboa, Portugal
| | - Elisabete Valério
- Departamento de Saúde Ambiental, Instituto Nacional de Saúde Doutor Ricardo Jorge, Avenida Padre Cruz, 1649-016, Lisboa, Portugal
| |
Collapse
|
36
|
Pascual-Benito M, Nadal-Sala D, Tobella M, Ballesté E, García-Aljaro C, Sabaté S, Sabater F, Martí E, Gracia CA, Blanch AR, Lucena F. Modelling the seasonal impacts of a wastewater treatment plant on water quality in a Mediterranean stream using microbial indicators. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2020; 261:110220. [PMID: 32148290 DOI: 10.1016/j.jenvman.2020.110220] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/09/2019] [Revised: 12/24/2019] [Accepted: 01/28/2020] [Indexed: 06/10/2023]
Abstract
Faecal pollution modelling is a valuable tool to evaluate and improve water management strategies, especially in a context of water scarcity. The reduction dynamics of five faecal indicator organisms (E. coli, spores of sulphite-reducing clostridia, somatic coliphages, GA17 bacteriophages and a human-specific Bifidobacterium molecular marker) were assessed in an intermittent Mediterranean stream affected by a wastewater treatment plant (WWTP). Using Bayesian inverse modelling, the decay rates of each indicator were correlated with two environmental drivers (temperature and streamflow downstream of the WWTP) and the generated model was used to evaluate the self-depuration distance (SDD) of the stream. A consistent increase of 1-2 log10 in the concentration of all indicators was detected after the discharge of the WWTP effluent. The decay rates showed seasonal variation, reaching a maximum in the dry season, when SDDs were also shorter and the stream had a higher capacity to self-depurate. High seasonality was observed for all faecal indicators except for the spores of sulphite-reducing clostridia. The maximum SDD ranged from 3 km for the spores of sulphite-reducing clostridia during the dry season and 15 km for the human-specific Bifidobacterium molecular marker during the wet season. The SDD provides a single standardized metric that integrates and compares different contamination indicators. It could be extended to other Mediterranean drainage basins and has the potential to integrate changes in land use and catchment water balance, a feature that will be especially useful in the transient climate conditions expected in the coming years.
Collapse
Affiliation(s)
- M Pascual-Benito
- Department of Genetics, Microbiology and Statistics, Faculty of Biology, University of Barcelona, Diagonal 643, 08028, Barcelona, Spain; The Water Research Institute, University of Barcelona, Montalegre 6, 08001, Barcelona, Spain.
| | - D Nadal-Sala
- Department of Evolutionary Biology, Ecology and Environmental Sciences, University of Barcelona, Diagonal 643, 08028, Barcelona, Spain; IMK-IFU (Karlsruhe Institute of Meteorology and Climate Research-Atmospheric Environmental Research), Kreuzeckbahnstraße 19, 82467, Garmisch-Partenkirchen, Germany
| | - M Tobella
- Department of Evolutionary Biology, Ecology and Environmental Sciences, University of Barcelona, Diagonal 643, 08028, Barcelona, Spain
| | - E Ballesté
- Department of Genetics, Microbiology and Statistics, Faculty of Biology, University of Barcelona, Diagonal 643, 08028, Barcelona, Spain; The Water Research Institute, University of Barcelona, Montalegre 6, 08001, Barcelona, Spain
| | - C García-Aljaro
- Department of Genetics, Microbiology and Statistics, Faculty of Biology, University of Barcelona, Diagonal 643, 08028, Barcelona, Spain; The Water Research Institute, University of Barcelona, Montalegre 6, 08001, Barcelona, Spain
| | - S Sabaté
- Department of Evolutionary Biology, Ecology and Environmental Sciences, University of Barcelona, Diagonal 643, 08028, Barcelona, Spain; CREAF (Center for Ecological Research and Forestry Applications), 08193, Cerdanyola del Vallès, Spain
| | - F Sabater
- Department of Evolutionary Biology, Ecology and Environmental Sciences, University of Barcelona, Diagonal 643, 08028, Barcelona, Spain; CREAF (Center for Ecological Research and Forestry Applications), 08193, Cerdanyola del Vallès, Spain
| | - E Martí
- Integrative Freshwater Ecology Group, Centre for Advanced Studies of Blanes (CEAB-CSIC), 17300, Blanes, Spain
| | - C A Gracia
- Department of Evolutionary Biology, Ecology and Environmental Sciences, University of Barcelona, Diagonal 643, 08028, Barcelona, Spain; CREAF (Center for Ecological Research and Forestry Applications), 08193, Cerdanyola del Vallès, Spain
| | - A R Blanch
- Department of Genetics, Microbiology and Statistics, Faculty of Biology, University of Barcelona, Diagonal 643, 08028, Barcelona, Spain; The Water Research Institute, University of Barcelona, Montalegre 6, 08001, Barcelona, Spain
| | - F Lucena
- Department of Genetics, Microbiology and Statistics, Faculty of Biology, University of Barcelona, Diagonal 643, 08028, Barcelona, Spain; The Water Research Institute, University of Barcelona, Montalegre 6, 08001, Barcelona, Spain
| |
Collapse
|
37
|
Douterelo I, Dutilh BE, Arkhipova K, Calero C, Husband S. Microbial diversity, ecological networks and functional traits associated to materials used in drinking water distribution systems. WATER RESEARCH 2020; 173:115586. [PMID: 32065938 DOI: 10.1016/j.watres.2020.115586] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/03/2019] [Revised: 01/22/2020] [Accepted: 02/02/2020] [Indexed: 06/10/2023]
Abstract
Drinking water distribution systems host complex microbial communities as biofilms that interact continuously with delivered water. Understanding the diversity, behavioural and functional characteristics will be a requisite for developing future monitoring strategies and protection against water-borne health risks. To improve understanding, this study investigates mobilisation and accumulation behaviour, microbial community structure and functional variations of biofilms developing on different pipe materials from within an operational network. Samples were collected from four pipes during a repeated flushing operation three months after an initial visit that used hydraulic forces to mobilise regenerating biofilms yet without impacting the upstream network. To minimise confounding factors, test sections were chosen with comparable daily hydraulic regimes, physical dimensions, and all connected straight of a common trunk main and within close proximity, hence similar water chemistry, pressure and age. Taxonomical results showed differences in colonising communities between pipe materials, with several genera, including the bacteria Pseudomonas and the fungi Cladosporium, present in every sample. Diverse bacterial communities dominated compared to more homogeneous fungal, or mycobiome, community distribution. The analysis of bacterial/fungal networks based on relative abundance of operational taxonomic units (OTUs) indicated microbial communities from cast iron pipes were more stable than communities from the non-ferrous pipe materials. Novel analysis of functional traits between all samples were found to be mainly associated to mobile genetic elements that play roles in determining links between cells, including phages, prophages, transposable elements, and plasmids. The use of functional traits can be considered for development in future surveillance methods, capable of delivering network condition information beyond that of limited conventional faecal indicator tests, that will help protect water quality and public health.
Collapse
Affiliation(s)
- I Douterelo
- Pennine Water Group, Department of Civil and Structural Engineering, Sir Frederick Mappin Building, University of Sheffield, Sheffield, S1 3JD, UK.
| | - B E Dutilh
- Theoretical Biology and Bioinformatics, Science for Life, Utrecht University, Hugo R. Kruytgebouw, Padualaan 8, 3584, CH, Utrecht, the Netherlands; Centre for Molecular and Biomolecular Informatics, Radboud University Medical Centre, Geert Grooteplein Zuid 26-28, 6525, GA, Nijmegen, the Netherlands
| | - K Arkhipova
- Theoretical Biology and Bioinformatics, Science for Life, Utrecht University, Hugo R. Kruytgebouw, Padualaan 8, 3584, CH, Utrecht, the Netherlands
| | - C Calero
- Pennine Water Group, Department of Civil and Structural Engineering, Sir Frederick Mappin Building, University of Sheffield, Sheffield, S1 3JD, UK
| | - S Husband
- Pennine Water Group, Department of Civil and Structural Engineering, Sir Frederick Mappin Building, University of Sheffield, Sheffield, S1 3JD, UK
| |
Collapse
|
38
|
Integrated Electrochemical Biosensors for Detection of Waterborne Pathogens in Low-Resource Settings. BIOSENSORS-BASEL 2020; 10:bios10040036. [PMID: 32294961 PMCID: PMC7236604 DOI: 10.3390/bios10040036] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/29/2020] [Revised: 03/21/2020] [Accepted: 04/05/2020] [Indexed: 12/24/2022]
Abstract
More than 783 million people worldwide are currently without access to clean and safe water. Approximately 1 in 5 cases of mortality due to waterborne diseases involve children, and over 1.5 million cases of waterborne disease occur every year. In the developing world, this makes waterborne diseases the second highest cause of mortality. Such cases of waterborne disease are thought to be caused by poor sanitation, water infrastructure, public knowledge, and lack of suitable water monitoring systems. Conventional laboratory-based techniques are inadequate for effective on-site water quality monitoring purposes. This is due to their need for excessive equipment, operational complexity, lack of affordability, and long sample collection to data analysis times. In this review, we discuss the conventional techniques used in modern-day water quality testing. We discuss the future challenges of water quality testing in the developing world and how conventional techniques fall short of these challenges. Finally, we discuss the development of electrochemical biosensors and current research on the integration of these devices with microfluidic components to develop truly integrated, portable, simple to use and cost-effective devices for use by local environmental agencies, NGOs, and local communities in low-resource settings.
Collapse
|
39
|
Shi XJ, Liu G, Zhang M, Zhao J, Li H, Yang Z, Bai H, Liang P, Lu Y. Membrane-sensitive bacterial DNA extractions and absolute quantitation of recovery efficiencies. THE SCIENCE OF THE TOTAL ENVIRONMENT 2020; 708:135125. [PMID: 31812430 DOI: 10.1016/j.scitotenv.2019.135125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/04/2019] [Revised: 10/21/2019] [Accepted: 10/21/2019] [Indexed: 06/10/2023]
Abstract
Absolute quantification of waterborne pathogens is mandatory for microbiological risk assessment (MRA). Determination of the DNA recovery efficiency is an essential step before the quantitative molecular measurements, which has been largely ignored. In this study, we compared the DNA recovery efficiency and quality of five extraction methods, including two modified phenol-chloroform-based extractions with mechanical shearing and three commercial kits for the extraction of DNA from indigenous mixed-bacteria culture of river water. All of the methods gave relatively satisfying results from the pelleted sample through centrifugation. However, the commercial kits provided surprisingly low DNA yields for membrane-filtered samples because of DNA trapping and/or absorption on the membrane. Integrating with enzymatic lysis, bath sonication, phenol extraction, and alcohol precipitation achieved highest DNA yields and an acceptable DNA integrity for quantitative PCR. A plasmid containing the human GADPH gene fragment was demonstrated to be a suitable spiking control for determining the absolute DNA recovery efficiency. The unexpectedly low efficiencies of commercial kit extractions imply the significant underestimation of pathogenic bacteria in previous studies, which should gain enough concern in the area of pathogen monitoring in the future.
Collapse
Affiliation(s)
- Xiao Jie Shi
- State Key Joint Laboratory of Environmental Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing 100084, China
| | - Gang Liu
- State Key Joint Laboratory of Environmental Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing 100084, China
| | - Mengyu Zhang
- State Key Joint Laboratory of Environmental Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing 100084, China
| | - Jinbo Zhao
- State Key Laboratory of Water Environment Simulation, School of Environment, Beijing Normal University, Beijing, China
| | - Huijun Li
- State Key Joint Laboratory of Environmental Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing 100084, China
| | - Zichao Yang
- Beijing North Canal Management Division, China
| | - Huiwen Bai
- Beijing North Canal Management Division, China
| | - Pu Liang
- Beijing North Canal Management Division, China
| | - Yun Lu
- State Key Joint Laboratory of Environmental Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing 100084, China.
| |
Collapse
|
40
|
Quantitative PCR Detection of Enteric Viruses in Wastewater and Environmental Water Sources by the Lisbon Municipality: A Case Study. WATER 2020. [DOI: 10.3390/w12020544] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Current regulations and legislation require critical revision to determine safety for alternative water sources and water reuse as part of the solution to global water crisis. In order to fulfill those demands, Lisbon municipality decided to start water reuse as part of a sustainable hydric resources management, and there was a need to confirm safety and safeguard for public health for its use in this context. For this purpose, a study was designed that included a total of 88 samples collected from drinking, superficial, underground water, and wastewater at three different treatment stages. Quantitative Polimerase Chain Reaction (PCR) detection (qPCR) of enteric viruses Norovirus (NoV) genogroups I (GI) and II (GII) and Hepatitis A (HepA) was performed, and also FIB (E. coli, enterococci and fecal coliforms) concentrations were assessed. HepA virus was only detected in one untreated influent sample, whereas NoV GI/ NoV GI were detected in untreated wastewater (100/100%), secondary treated effluent (47/73%), and tertiary treated effluent (33/20%). Our study proposes that NoV GI and GII should be further studied to provide the support that they may be suitable indicators for water quality monitoring targeting wastewater treatment efficiency, regardless of the level of treatment.
Collapse
|
41
|
Faecal pollution affects abundance and diversity of aquatic microbial community in anthropo-zoogenically influenced lotic ecosystems. Sci Rep 2019; 9:19469. [PMID: 31857659 PMCID: PMC6923421 DOI: 10.1038/s41598-019-56058-x] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2019] [Accepted: 11/15/2019] [Indexed: 12/14/2022] Open
Abstract
The aquatic microbiota is known to be an important factor in the sustainability of the natural water ecosystems. However, the microbial community also might include pathogens, which result in very serious waterborne diseases in humans and animals. Faecal pollution is the major cause of these diseases. Therefore, it is of immense importance to assess the potential impact of faecal pollution, originating from both anthropogenic and zoogenic sources, on the profile of microbial communities in natural water environments. To this end, the microbial taxonomic diversity of lotic ecosystems in different regions of Norway, representing urban and rural areas, exposed to various levels of faecal pollution, was investigated over the course of a 1-year period. The highest microbial diversity was found in rural water that was the least faecally polluted, while the lowest was found in urban water with the highest faecal contamination. The overall diversity of the aquatic microbial community was significantly reduced in severely polluted water. In addition, the community compositions diverged between waters where the dominant pollution sources were of anthropogenic or zoogenic origin. The results provide new insight into the understanding of how faecal water contamination, specifically that of different origins, influences the microbial diversity of natural waters.
Collapse
|
42
|
Bigham T, Dooley JS, Ternan NG, Snelling WJ, Héctor Castelán M, Davis J. Assessing microbial water quality: Electroanalytical approaches to the detection of coliforms. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2019.115670] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
|
43
|
Casimero C, Bigham T, McGlynn RJ, Dooley JS, Ternan NG, Snelling WJ, Critchley ME, Zinkel CL, Smith RB, Sabogal-Paz LP, Davis J. Electroanalytical properties of chlorophenol red at disposable carbon electrodes: Implications for Escherichia coli detection. Bioelectrochemistry 2019; 130:107321. [DOI: 10.1016/j.bioelechem.2019.06.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2019] [Revised: 06/19/2019] [Accepted: 06/19/2019] [Indexed: 10/26/2022]
|
44
|
Sha'arani S, Azizan SNF, Md Akhir FN, Muhammad Yuzir MA, Othman N, Zakaria Z, Mohd Noor MJM, Hara H. Removal efficiency of Gram-positive and Gram-negative bacteria using a natural coagulant during coagulation, flocculation, and sedimentation processes. WATER SCIENCE AND TECHNOLOGY : A JOURNAL OF THE INTERNATIONAL ASSOCIATION ON WATER POLLUTION RESEARCH 2019; 80:1787-1795. [PMID: 32039910 DOI: 10.2166/wst.2019.433] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Staphylococcus sp. as Gram-positive and Escherichia coli as Gram-negative are bacterial pathogens and can cause primary bloodstream infections and food poisoning. Coagulation, flocculation, and sedimentation processes could be a reliable treatment for bacterial removal because suspended, colloidal, and soluble particles can be removed. Chemical coagulants, such as alum, are commonly used. However, these chemical coagulants are not environmentally friendly. This present study evaluated the effectiveness of coagulation, flocculation, and sedimentation processes for removing Staphylococcus sp. and E. coli using diatomite with standard jar test equipment at different pH values. Staphylococcus sp. demonstrated 85.61% and 77.23% significant removal in diatomite and alum, respectively, at pH 5. At pH 7, the removal efficiency decreased to 79.41% and 64.13% for Staphylococcus sp. and E. coli, respectively. At pH 9, there was a decrease in Staphylococcus sp. after adding diatomite or alum compared with that of E. coli. The different removal efficiencies of the Gram-positive and Gram-negative bacteria could be owing to the membrane composition and different structures in the bacteria. This study indicates that diatomite has higher efficiency in removing bacteria at pH 5 and can be considered as a potential coagulant to replace alum for removing bacteria by the coagulation process.
Collapse
Affiliation(s)
- Shazwana Sha'arani
- Department of Environmental Engineering and Green Technology, Malaysia-Japan International Institute of Technology, Universiti Teknologi Malaysia, Jalan Sultan Yahya Petra, 54100 Kuala Lumpur, Malaysia
| | - Siti Noor Fitriah Azizan
- Department of Environmental Engineering and Green Technology, Malaysia-Japan International Institute of Technology, Universiti Teknologi Malaysia, Jalan Sultan Yahya Petra, 54100 Kuala Lumpur, Malaysia
| | - Fazrena Nadia Md Akhir
- Department of Environmental Engineering and Green Technology, Malaysia-Japan International Institute of Technology, Universiti Teknologi Malaysia, Jalan Sultan Yahya Petra, 54100 Kuala Lumpur, Malaysia
| | - Muhamad Ali Muhammad Yuzir
- Department of Environmental Engineering and Green Technology, Malaysia-Japan International Institute of Technology, Universiti Teknologi Malaysia, Jalan Sultan Yahya Petra, 54100 Kuala Lumpur, Malaysia
| | - Nor'azizi Othman
- Department of Mechanical Precision Engineering, Malaysia-Japan International Institute of Technology, Universiti Teknologi Malaysia, Jalan Sultan Yahya Petra, 54100 Kuala Lumpur, Malaysia
| | - Zuriati Zakaria
- Department of Environmental Engineering and Green Technology, Malaysia-Japan International Institute of Technology, Universiti Teknologi Malaysia, Jalan Sultan Yahya Petra, 54100 Kuala Lumpur, Malaysia
| | - Megat Johari Megat Mohd Noor
- Department of Environmental Engineering and Green Technology, Malaysia-Japan International Institute of Technology, Universiti Teknologi Malaysia, Jalan Sultan Yahya Petra, 54100 Kuala Lumpur, Malaysia
| | - Hirofumi Hara
- Department of Chemical Process Engineering, Malaysia-Japan International Institute of Technology, Universiti Teknologi Malaysia, Jalan Sultan Yahya Petra, 54100 Kuala Lumpur, Malaysia E-mail:
| |
Collapse
|
45
|
Singh AK, Das S, Singh S, Pradhan N, Gajamer VR, Kumar S, Lepcha YD, Tiwari HK. Physicochemical Parameters and Alarming Coliform Count of the Potable Water of Eastern Himalayan State Sikkim: An Indication of Severe Fecal Contamination and Immediate Health Risk. Front Public Health 2019; 7:174. [PMID: 31355173 PMCID: PMC6636254 DOI: 10.3389/fpubh.2019.00174] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2019] [Accepted: 06/10/2019] [Indexed: 02/05/2023] Open
Abstract
Continuous decline in potable water sources has raised serious concerns over human health. Developing countries are the most affected in this regard due to a lack of proper hygiene maintenance. Sikkim, an Eastern Himalayan state with mountains as the predominant topological features, harbors several perennial natural springs. Spring water is the primary source of potable water for the population in four districts of the state viz. East, West, North and South. Recent outbreaks of water-borne diseases and the relative lack of scientific studies on its potential correlation with the water quality of the area have educed this study. Physicochemical parameters of springs, community reservoirs, and household water were analyzed by ICP-MS and multi probe meter. Using the membrane filtration method, the microbial quality of the water samples during different seasons was assessed, primarily evaluating the presence of fecal indicators viz. Escherichia coli, total coliform and Enterococcus. The seasonal risk category of the water sources was also determined. Most of the physicochemical parameters of the spring water were within the permissible limits of WHO standards. However, water from four districts was recorded with traces of toxic heavy metals like mercury (0.001-0.007 mg/l), lead (0.001-0.007 mg/l), and selenium (0.526-0.644 mg/l), which are above the permissible limits of WHO. All the spring water samples were categorized as Mg-HCO 3 - type and can be predicted as shallow fresh ground water based on the piper analysis. Microbial confirmatory testing indicated severe fecal contamination of water sources with high counts of total coliform (TC), Escherichia coli (EC) and Enterococcus (EN). The highest level of TC was recorded from West Sikkim (37.26 cfu/100 ml) and the lowest in North Sikkim (22.13 cfu/100 ml). The highest level of contamination of E. coli and Enterococcus was found in East Sikkim (EC = 8.7 cfu/100 ml; EN = 2.08 cfu/100 ml) followed by South Sikkim (EC = 8.4 cfu/100 ml; EN = 2.05 cfu/100 ml). There was a significant positive correlation between the contamination levels of the spring water and the community reservoir tank. As far as the seasonal variation is concerned, the rainy season showed the most contamination with coliform correlating with a high incidence of different water-borne diseases (East = 86%; West = 100%; South = 100%; North = 80%).
Collapse
Affiliation(s)
- Ashish Kumar Singh
- Department of Microbiology, School of Life Sciences, Sikkim University, Gangtok, India
| | - Saurav Das
- Department of Microbiology, School of Life Sciences, Sikkim University, Gangtok, India
| | - Samer Singh
- Department of Microbial Biotechnology, Panjab University, Chandigarh, India
- Centre of Experimental Medicine & Surgery, Institute of Medical Sciences, Banaras Hindu University, Varanasi, India
| | - Nilu Pradhan
- Department of Microbiology, School of Life Sciences, Sikkim University, Gangtok, India
| | - Varsha Rani Gajamer
- Department of Microbiology, School of Life Sciences, Sikkim University, Gangtok, India
| | - Santosh Kumar
- Department of Microbiology, School of Life Sciences, Sikkim University, Gangtok, India
| | - Yangchen D. Lepcha
- State Institute of Rural Development, Government of Sikkim, Gangtok, India
| | - Hare K. Tiwari
- Department of Microbiology, School of Life Sciences, Sikkim University, Gangtok, India
| |
Collapse
|
46
|
Vadde KK, McCarthy AJ, Rong R, Sekar R. Quantification of Microbial Source Tracking and Pathogenic Bacterial Markers in Water and Sediments of Tiaoxi River (Taihu Watershed). Front Microbiol 2019; 10:699. [PMID: 31105648 PMCID: PMC6492492 DOI: 10.3389/fmicb.2019.00699] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2018] [Accepted: 03/20/2019] [Indexed: 12/13/2022] Open
Abstract
Taihu Lake is one of the largest freshwater lakes in China, serving as an important source of drinking water; >60% of source water to this lake is provided by the Tiaoxi River. This river faces serious fecal contamination issues, and therefore, a comprehensive investigation to identify the sources of fecal contamination was carried out and is presented here. The performance of existing universal (BacUni and GenBac), human (HF183-Taqman, HF183-SYBR, BacHum, and Hum2), swine (Pig-2-Bac), ruminant (BacCow), and avian (AV4143 and GFD) associated microbial source tracking (MST) markers was evaluated prior to their application in this region. The specificity and sensitivity results indicated that BacUni, HF183-TaqMan, Pig-2-Bac, and GFD assays are the most suitable in identifying human and animal fecal contamination. Therefore, these markers along with marker genes specific to selected bacterial pathogens were quantified in water and sediment samples of the Tiaoxi River, collected from 15 locations over three seasons during 2014 and 2015. Total/universal Bacteroidales markers were detected in all water and sediment samples (mean concentration 6.22 log10 gene copies/100 ml and 6.11 log10 gene copies/gram, respectively), however, the detection of host-associated MST markers varied. Human and avian markers were the most frequently detected in water samples (97 and 89%, respectively), whereas in sediment samples, only human-associated markers were detected more often (86%) than swine (64%) and avian (8.8%) markers. The results indicate that several locations in the Tiaoxi River are heavily polluted by fecal contamination and this correlated well with land use patterns. Among the five bacterial pathogens tested, Shigella spp. and Campylobacter jejuni were the most frequently detected pathogens in water (60% and 62%, respectively) and sediment samples (91% and 53%, respectively). Shiga toxin-producing Escherichia coli (STEC) and pathogenic Leptospira spp. were less frequently detected in water samples (55% and 33%, respectively) and sediment samples (51% and 13%, respectively), whereas E. coli O157:H7 was only detected in sediment samples (11%). Overall, the higher prevalence and concentrations of Campylobacter jejuni, Shigella spp., and STEC, along with the MST marker detection at a number of locations in the Tiaoxi River, indicates poor water quality and a significant human health risk associated with this watercourse. GRAPHICAL ABSTRACTTracking fecal contamination and pathogens in watersheds using molecular methods.
Collapse
Affiliation(s)
- Kiran Kumar Vadde
- Department of Biological Sciences, Xi’an Jiaotong-Liverpool University, Suzhou, China
| | - Alan J. McCarthy
- Microbiology Research Group, Institute of Integrative Biology, University of Liverpool, Liverpool, United Kingdom
| | - Rong Rong
- Department of Biological Sciences, Xi’an Jiaotong-Liverpool University, Suzhou, China
| | - Raju Sekar
- Department of Biological Sciences, Xi’an Jiaotong-Liverpool University, Suzhou, China
| |
Collapse
|
47
|
Bigham T, Casimero C, Dooley JS, Ternan NG, Snelling WJ, Davis J. Microbial water quality: Voltammetric detection of coliforms based on riboflavin–ferrocyanide redox couples. Electrochem commun 2019. [DOI: 10.1016/j.elecom.2019.02.022] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
|
48
|
Russo N, Marzo A, Randazzo C, Caggia C, Toscano A, Cirelli GL. Constructed wetlands combined with disinfection systems for removal of urban wastewater contaminants. THE SCIENCE OF THE TOTAL ENVIRONMENT 2019; 656:558-566. [PMID: 30529960 DOI: 10.1016/j.scitotenv.2018.11.417] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/11/2018] [Revised: 11/27/2018] [Accepted: 11/27/2018] [Indexed: 06/09/2023]
Abstract
The removal efficiency of an urban wastewater treatment plant (WWTP) to obtain an effluent suitable for agriculture reuse was evaluated in a one-year period, taking into account the Italian wastewater limits and the recent European proposal for the minimum requirements water quality for agricultural irrigation. The secondary effluent of WWTP was treated by three full-scale horizontal sub-surface flow (H-SSF) constructed wetlands (CWs), working in parallel, planted with different macrophytes species, and combined with a UV device and a lagooning system running in series. The H-SSF CW system effectively reduced physico-chemical pollutants and its efficiency was steady over the investigation period, while, Escherichia coli densities always exceed the Italian limits required for wastewater reuse in agriculture. The UV system significantly reduced the microbiological indicators, eliminating E. coli, in compliance with the Italian regulation, and somatic coliphages, although a variable efficacy against total coliforms and enterococci, especially in winter season, was achieved. Although the lagooning unit provides a high removal of the main microbial groups, it did not reduce physico-chemical parameters. Even if the overall performance target, for the whole treatment chain, met the recent log10 reduction (≥5.0), required by the European Commission, the persistence of enterococci, especially in winter season, poses a matter of concern for public health, for the potential risk to serve as a genetic reservoir of transferable antibiotic-resistance.
Collapse
Affiliation(s)
- Nunziatina Russo
- Department of Agricultural, Food and Environment (Di3A), University of Catania, Via Santa Sofia 100, Catania 95123, Italy
| | - Alessia Marzo
- Center for the Conservation and Management of Nature and Agroecosystems (CUTGANA), University of Catania, via Santa Sofia 98, 95123 Catania, Italy.
| | - Cinzia Randazzo
- Department of Agricultural, Food and Environment (Di3A), University of Catania, Via Santa Sofia 100, Catania 95123, Italy
| | - Cinzia Caggia
- Department of Agricultural, Food and Environment (Di3A), University of Catania, Via Santa Sofia 100, Catania 95123, Italy
| | - Attilio Toscano
- Department of Agricultural and Food Sciences (DISTAL), Alma Mater Studiorum-University of Bologna, Viale Giuseppe Fanin 50, 40127 Bologna, Italy
| | - Giuseppe Luigi Cirelli
- Department of Agricultural, Food and Environment (Di3A), University of Catania, Via Santa Sofia 100, Catania 95123, Italy
| |
Collapse
|
49
|
Perrin Y, Bouchon D, Delafont V, Moulin L, Héchard Y. Microbiome of drinking water: A full-scale spatio-temporal study to monitor water quality in the Paris distribution system. WATER RESEARCH 2019; 149:375-385. [PMID: 30471533 DOI: 10.1016/j.watres.2018.11.013] [Citation(s) in RCA: 53] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/18/2018] [Revised: 10/25/2018] [Accepted: 11/05/2018] [Indexed: 05/22/2023]
Abstract
The microbiological water quality of drinking water distribution system (DWDS) is of primary importance for human health. High-throughput sequencing has gained more and more attention in the last decade to describe this microbial diversity in water networks. However, there are few studies describing this approach on large drinking water distribution systems and for extended periods of time. To fill this gap and observe the potential subtle variation in microbiota of a water network through time and space, we aimed to apply high-throughput sequencing of the 16S rRNA gene approach to characterize bacterial communities of the Paris' DWDS over a one-year period. In this study, the Paris network, composed of four different DWDSs, was sampled at 31 sites, each month for one year. The sampling campaign was one of the largest described so far (n = 368) and the importance of key spatio-temporal and physico-chemical parameters was investigated. Overall, 1321 taxa were identified within the Paris network, although only fifteen of them were found in high relative abundance (>1%) in all samples. Two genera, Phreatobacter and Hyphomicrobium were dominant. The whole bacterial diversity was not significantly affected between the four DWDSs (spatial parameter) and by physico-chemical parameters. However, the bacterial diversity was slightly modified over the one-year period (temporal parameter) as we were able to observe DWDS microbiome perturbations, presumably linked to a preceding flood event. Comparison of high-throughput sequencing of the 16S rRNA gene amplicons vs. cultivation-based techniques showed that only 1.8% of bacterial diversity was recovered through cultivation. High throughput sequencing has made it possible to monitor DWDS more accurately than conventional methods by describing the whole diversity and detecting slight fluctuations in bacterial communities. This method would be further used to supervise drinking water networks, to follow any perturbations due to internals events (such as treatments) or external events (such as flooding).
Collapse
Affiliation(s)
- Yoann Perrin
- Laboratoire Ecologie et Biologie des Interactions, Equipes Microbiologie de l'Eau, et., Ecologie, Evolution, Symbiose, Université de Poitiers, UMR CNRS 7267, F-86073, Poitiers, France; Eau de Paris, Direction de la Recherche et du Développement pour la Qualité de l'Eau, R&D Biologie, 33, Avenue Jean Jaurès, F-94200, Ivry sur Seine, France
| | - Didier Bouchon
- Laboratoire Ecologie et Biologie des Interactions, Equipes Microbiologie de l'Eau, et., Ecologie, Evolution, Symbiose, Université de Poitiers, UMR CNRS 7267, F-86073, Poitiers, France
| | - Vincent Delafont
- Laboratoire Ecologie et Biologie des Interactions, Equipes Microbiologie de l'Eau, et., Ecologie, Evolution, Symbiose, Université de Poitiers, UMR CNRS 7267, F-86073, Poitiers, France
| | - Laurent Moulin
- Eau de Paris, Direction de la Recherche et du Développement pour la Qualité de l'Eau, R&D Biologie, 33, Avenue Jean Jaurès, F-94200, Ivry sur Seine, France.
| | - Yann Héchard
- Laboratoire Ecologie et Biologie des Interactions, Equipes Microbiologie de l'Eau, et., Ecologie, Evolution, Symbiose, Université de Poitiers, UMR CNRS 7267, F-86073, Poitiers, France.
| |
Collapse
|
50
|
Knowledge, Attitude, and Practice on Hygiene and Morbidity Status among Tertiary Students: The Case of Kotebe Metropolitan University, Addis Ababa, Ethiopia. JOURNAL OF ENVIRONMENTAL AND PUBLIC HEALTH 2018; 2018:2094621. [PMID: 30228823 PMCID: PMC6136465 DOI: 10.1155/2018/2094621] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/06/2018] [Revised: 07/14/2018] [Accepted: 07/30/2018] [Indexed: 01/17/2023]
Abstract
Considerable fractions of the world's diseases are communicable, of which over 60% are infectious. Knowledge, attitude, and practice of hygiene are very important to decrease these disease burdens especially in places like higher education institutions. This study is aimed at revealing the status and gaps on knowledge, attitude, and practice of hygiene among Kotebe Metropolitan University students. Alongside, morbidity records of the students' clinic are reviewed. Sampled regular students who are boarding and who serve the students' canteen are studied. The investigation applied a cross-sectional study design. A structured questionnaire is administered following a pretest, and the data collected are analyzed using “SPSS v.20.” The review on morbidity record showed that the leading infections so far are respiratory (47%), gastrointestinal (amoebiasis, giardiasis, and typhoid) (34%), and eye and skin infections (16%). Regarding the responses to the knowledge questions, 1451 (60.8%) were correct while 934 (39.2%) were incorrect. Concerning handwashing as knowledge question, significant difference (p ≈ 0.00) existed between genders. Over 50% of the respondents do think parasitic infections typically amoeba is acquired not due to the contaminated vegetables, but rather they assume that such vegetables trigger those parasites already lodging in their gut. Above 60% of the respondents agreed that sharing drinking cups as a sign of affection as unfavorable attitude. In relation to that, the students' attitude highly varies by gender. However, the responses on hygiene practice enquiries appear to be promising. Further, the students do some practice while not having the desired level of knowledge on hygiene. Generally, there is a considerable gap in the knowledge, attitude, and practice of hygiene among students.
Collapse
|