151
|
Powers CM, Gift J, Lehmann GM. Sparking connections: toward better linkages between research and human health policy-an example with multiwalled carbon nanotubes. Toxicol Sci 2014; 141:6-17. [PMID: 24928890 DOI: 10.1093/toxsci/kfu117] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Risk assessment and subsequent risk management of environmental contaminants can benefit from early collaboration among researchers, risk assessors, and risk managers. The benefits of collaboration in research planning are particularly evident in light of (1) increasing calls to expand upon the risk assessment paradigm to include a greater focus on problem formulation and consideration of potential tradeoffs between risk management options, and (2) decreasing research budgets. Strategically connecting research planning to future decision making may be most critical in areas of emerging science for which data are often insufficient to clearly direct targeted research to support future risk assessment and management efforts. This article illustrates an application of the comprehensive environmental assessment approach to inform research planning for future risk assessment and management of one emerging material, multiwalled carbon nanotubes (MWCNTs). High-priority research areas identified for MWCNTs in flame-retardant coatings applied to upholstery textiles included the following: release across the product life cycle; environmental transport, transformation and fate in air, wastewater and sediment; exposure in human occupational and consumer groups; kinetics in the human body; impacts on human health and aquatic populations; and impacts on economic, social, and environmental resources. This article focuses on specific research questions related to human health and how these may connect to future risk assessments and risk management efforts. Such connections will support more effective collaborations across the scientific community and may inform the prioritization of research funding opportunities for emerging materials like MWCNTs.
Collapse
Affiliation(s)
- Christina M Powers
- National Center for Environmental Assessment, Office of Research and Development, U.S. Environmental Protection Agency, Research Triangle Park, North Carolina 27711
| | - Jeff Gift
- National Center for Environmental Assessment, Office of Research and Development, U.S. Environmental Protection Agency, Research Triangle Park, North Carolina 27711
| | - Geniece M Lehmann
- National Center for Environmental Assessment, Office of Research and Development, U.S. Environmental Protection Agency, Research Triangle Park, North Carolina 27711
| |
Collapse
|
152
|
Saito N, Haniu H, Usui Y, Aoki K, Hara K, Takanashi S, Shimizu M, Narita N, Okamoto M, Kobayashi S, Nomura H, Kato H, Nishimura N, Taruta S, Endo M. Safe clinical use of carbon nanotubes as innovative biomaterials. Chem Rev 2014; 114:6040-79. [PMID: 24720563 PMCID: PMC4059771 DOI: 10.1021/cr400341h] [Citation(s) in RCA: 140] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2013] [Indexed: 02/06/2023]
Affiliation(s)
- Naoto Saito
- Institute
for Biomedical Sciences, Shinshu University, Asahi 3-1-1, Matsumoto 390-8621, Japan
| | - Hisao Haniu
- Department
of Orthopaedic Surgery, Shinshu University
School of Medicine, Asahi
3-1-1, Matsumoto 390-8621, Japan
| | - Yuki Usui
- Department
of Orthopaedic Surgery, Shinshu University
School of Medicine, Asahi
3-1-1, Matsumoto 390-8621, Japan
- Research Center for Exotic Nanocarbons, and Faculty of Engineering, Shinshu University, Wakasato 4-17-1, Nagano 380-8553, Japan
| | - Kaoru Aoki
- Department
of Orthopaedic Surgery, Shinshu University
School of Medicine, Asahi
3-1-1, Matsumoto 390-8621, Japan
| | - Kazuo Hara
- Department
of Orthopaedic Surgery, Shinshu University
School of Medicine, Asahi
3-1-1, Matsumoto 390-8621, Japan
| | - Seiji Takanashi
- Department
of Orthopaedic Surgery, Shinshu University
School of Medicine, Asahi
3-1-1, Matsumoto 390-8621, Japan
| | - Masayuki Shimizu
- Department
of Orthopaedic Surgery, Shinshu University
School of Medicine, Asahi
3-1-1, Matsumoto 390-8621, Japan
| | - Nobuyo Narita
- Department
of Orthopaedic Surgery, Shinshu University
School of Medicine, Asahi
3-1-1, Matsumoto 390-8621, Japan
| | - Masanori Okamoto
- Department
of Orthopaedic Surgery, Shinshu University
School of Medicine, Asahi
3-1-1, Matsumoto 390-8621, Japan
| | - Shinsuke Kobayashi
- Department
of Orthopaedic Surgery, Shinshu University
School of Medicine, Asahi
3-1-1, Matsumoto 390-8621, Japan
| | - Hiroki Nomura
- Department
of Orthopaedic Surgery, Shinshu University
School of Medicine, Asahi
3-1-1, Matsumoto 390-8621, Japan
| | - Hiroyuki Kato
- Department
of Orthopaedic Surgery, Shinshu University
School of Medicine, Asahi
3-1-1, Matsumoto 390-8621, Japan
| | - Naoyuki Nishimura
- R&D
Center, Nakashima Medical Co. Ltd., Haga 5322, Kita-ku, Okayama 701-1221, Japan
| | - Seiichi Taruta
- Research Center for Exotic Nanocarbons, and Faculty of Engineering, Shinshu University, Wakasato 4-17-1, Nagano 380-8553, Japan
| | - Morinobu Endo
- Research Center for Exotic Nanocarbons, and Faculty of Engineering, Shinshu University, Wakasato 4-17-1, Nagano 380-8553, Japan
| |
Collapse
|
153
|
Fujita K, Fukuda M, Fukui H, Horie M, Endoh S, Uchida K, Shichiri M, Morimoto Y, Ogami A, Iwahashi H. Intratracheal instillation of single-wall carbon nanotubes in the rat lung induces time-dependent changes in gene expression. Nanotoxicology 2014; 9:290-301. [PMID: 24911292 PMCID: PMC4487535 DOI: 10.3109/17435390.2014.921737] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
The use of carbon nanotubes in the industry has grown; however, little is known about their toxicological mechanism of action. Single-wall carbon nanotube (SWCNT) suspensions were administered by single intratracheal instillation in rats. Persistence of alveolar macrophage-containing granuloma was observed around the sites of SWCNT aggregation at 90 days post-instillation in 0.2-mg- or 0.4-mg-injected doses per rat. Meanwhile, gene expression profiling revealed that a large number of genes involved in the inflammatory response were markedly upregulated until 90 days or 180 days post-instillation. Subsequently, gene expression patterns were dramatically altered at 365 days post-instillation, and the number of upregulated genes involved in the inflammatory response was reduced. These results suggested that alveolar macrophage-containing granuloma reflected a characteristic of the histopathological transition period from the acute-phase to the subchronic-phase of inflammation, as well as pulmonary acute phase response persistence up to 90 or 180 days after intratracheal instillation in this experimental setting. The expression levels of the genes Ctsk, Gcgr, Gpnmb, Lilrb4, Marco, Mreg, Mt3, Padi1, Slc26a4, Spp1, Tnfsf4 and Trem2 were persistently upregulated in a dose-dependent manner until 365 days post-instillation. In addition, the expression levels of Atp6v0d2, Lpo, Mmp7, Mmp12 and Rnase9 were significantly upregulated until 754 days post-instillation. We propose that these persistently upregulated genes in the chronic-phase response following the acute-phase response act as potential biomarkers in lung tissue after SWCNT instillation. This study provides further insight into the time-dependent changes in genomic expression associated with the pulmonary toxicity of SWCNTs.
Collapse
Affiliation(s)
- Katsuhide Fujita
- Research Institute of Science for Safety and Sustainability, National Institute of Advanced Industrial Science and Technology (AIST) , Tsukuba , Japan
| | | | | | | | | | | | | | | | | | | |
Collapse
|
154
|
Rotoli BM, Gatti R, Movia D, Bianchi MG, Di Cristo L, Fenoglio I, Sonvico F, Bergamaschi E, Prina-Mello A, Bussolati O. Identifying contact-mediated, localized toxic effects of MWCNT aggregates on epithelial monolayers: a single-cell monitoring toxicity assay. Nanotoxicology 2014; 9:230-41. [PMID: 24873759 DOI: 10.3109/17435390.2014.918203] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Aggregates of multiwalled carbon nanotubes (MWCNT) impair the barrier properties of human airway cell monolayers. To resolve the mechanism of the barrier alteration, monolayers of Calu-3 human airway epithelial cells were exposed to aggregated MWCNT. At the cell-population level, trans-epithelial electrical resistance (TEER) was used as an indicator of barrier competence, caspase activity was assessed with standard biochemical assays, and cell viability was investigated by biochemical techniques and high-throughput screening (HTS) technique based on automated epifluorescence microscopy. At cell level, the response to MWCNT was investigated with confocal microscopy, by evaluating cell death (calcein/propidium iodide (PI)), proliferation (Ki-67), and apoptosis (caspase activity). At the cell-population level, exposure to aggregated MWCNT caused a decrease in TEER, which was not associated with a decrease in cell viability or onset of apoptosis even after an 8-d exposure. In contrast, confocal imaging demonstrated contact with MWCNT aggregates triggered cell death after 24 h of exposure. In the presence of a natural surfactant, both TEER decrease and contact-mediated toxicity were mitigated. With confocal imaging, increased proliferation and apoptosis were detected in Calu-3 cells next to the aggregates. Contact-mediated cytotoxicity was recorded in two additional cell lines (BEAS-2B and A549) derived from human airways. Similar results were confirmed by adopting two additional MWCNT preparations with different physico-chemical features. This indicates MWCNT caused localized damage to airway epithelial monolayers in vitro and altered the apoptotic and proliferative rate of epithelial cells in close proximity to the aggregates. These findings provide evidence on the pathway by which MWCNT aggregates impair airway barrier function, and support the use of imaging techniques as a possible regulatory-decision supporting tool to identify effects of aggregated nanomaterials not readily detected at cell population level.
Collapse
|
155
|
Haniu H, Saito N, Matsuda Y, Tsukahara T, Usui Y, Maruyama K, Takanashi S, Aoki K, Kobayashi S, Nomura H, Tanaka M, Okamoto M, Kato H. Biological responses according to the shape and size of carbon nanotubes in BEAS-2B and MESO-1 cells. Int J Nanomedicine 2014; 9:1979-90. [PMID: 24790438 PMCID: PMC4000181 DOI: 10.2147/ijn.s58661] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
This study aimed to investigate the influence of the shape and size of multi-walled carbon nanotubes (MWCNTs) and cup-stacked carbon nanotubes (CSCNTs) on biological responses in vitro. Three types of MWCNTs – VGCF®-X, VGCF®-S, and VGCF® (vapor grown carbon fibers; with diameters of 15, 80, and 150 nm, respectively) – and three CSCNTs of different lengths (CS-L, 20–80 μm; CS-S, 0.5–20 μm; and CS-M, of intermediate length) were tested. Human bronchial epithelial (BEAS-2B) and malignant pleural mesothelioma cells were exposed to the CNTs (1–50 μg/mL), and cell viability, permeability, uptake, total reactive oxygen species/superoxide production, and intracellular acidity were measured. CSCNTs were less toxic than MWCNTs in both cell types over a 24-hour exposure period. The cytotoxicity of endocytosed MWCNTs varied according to cell type/size, while that of CSCNTs depended on tube length irrespective of cell type. CNT diameter and length influenced cell aggregation and injury extent. Intracellular acidity increased independently of lysosomal activity along with the number of vacuoles in BEAS-2B cells exposed for 24 hours to either CNT (concentration, 10 μg/mL). However, total reactive oxygen species/superoxide generation did not contribute to cytotoxicity. The results demonstrate that CSCNTs could be suitable for biological applications and that CNT shape and size can have differential effects depending on cell type, which can be exploited in the development of highly specialized, biocompatible CNTs.
Collapse
Affiliation(s)
- Hisao Haniu
- Department of Orthopaedic Surgery, Shinshu University School of Medicine, Nagano, Japan ; Insutitute for Biomedical Sciences, Shinshu University, Nagano, Japan
| | - Naoto Saito
- Insutitute for Biomedical Sciences, Shinshu University, Nagano, Japan ; Department of Applied Physical Therapy, Shinshu University School of Health Sciences, Nagano, Japan
| | - Yoshikazu Matsuda
- Clinical Pharmacology Educational Center, Nihon Pharmaceutical University, Saitama, Japan
| | - Tamotsu Tsukahara
- Department of Hematology and Immunology, Kanazawa Medical University, Ishikawa, Japan
| | - Yuki Usui
- Department of Orthopaedic Surgery, Shinshu University School of Medicine, Nagano, Japan ; Research Center for Exotic Nanocarbons, Shinshu University, Nagano, Japan ; Aizawa Hospital, Sports Medicine Center, Nagano, Japan
| | - Kayo Maruyama
- Insutitute for Biomedical Sciences, Shinshu University, Nagano, Japan ; Department of Applied Physical Therapy, Shinshu University School of Health Sciences, Nagano, Japan
| | - Seiji Takanashi
- Department of Orthopaedic Surgery, Shinshu University School of Medicine, Nagano, Japan
| | - Kaoru Aoki
- Department of Orthopaedic Surgery, Shinshu University School of Medicine, Nagano, Japan
| | - Shinsuke Kobayashi
- Department of Orthopaedic Surgery, Shinshu University School of Medicine, Nagano, Japan
| | - Hiroki Nomura
- Department of Orthopaedic Surgery, Shinshu University School of Medicine, Nagano, Japan
| | - Manabu Tanaka
- Department of Orthopaedic Surgery, Shinshu University School of Medicine, Nagano, Japan
| | - Masanori Okamoto
- Department of Orthopaedic Surgery, Shinshu University School of Medicine, Nagano, Japan
| | - Hiroyuki Kato
- Department of Orthopaedic Surgery, Shinshu University School of Medicine, Nagano, Japan
| |
Collapse
|
156
|
Braakhuis HM, Park MVDZ, Gosens I, De Jong WH, Cassee FR. Physicochemical characteristics of nanomaterials that affect pulmonary inflammation. Part Fibre Toxicol 2014; 11:18. [PMID: 24725891 PMCID: PMC3996135 DOI: 10.1186/1743-8977-11-18] [Citation(s) in RCA: 199] [Impact Index Per Article: 19.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2013] [Accepted: 04/04/2014] [Indexed: 02/02/2023] Open
Abstract
The increasing manufacture and use of products based on nanotechnology raises concerns for both workers and consumers. Various studies report induction of pulmonary inflammation after inhalation exposure to nanoparticles, which can vary in aspects such as size, shape, charge, crystallinity, chemical composition, and dissolution rate. Each of these aspects can affect their toxicity, although it is largely unknown to what extent. The aim of the current review is to analyse published data on inhalation of nanoparticles to identify and evaluate the contribution of their physicochemical characteristics to the onset and development of pulmonary inflammation. Many physicochemical characteristics of nanoparticles affect their lung deposition, clearance, and pulmonary response that, in combination, ultimately determine whether pulmonary inflammation will occur and to what extent. Lung deposition is mainly determined by the physical properties of the aerosol (size, density, shape, hygroscopicity) in relation to airflow and the anatomy of the respiratory system, whereas clearance and translocation of nanoparticles are mainly determined by their geometry and surface characteristics. Besides size and chemical composition, other physicochemical characteristics influence the induction of pulmonary inflammation after inhalation. As some nanoparticles dissolve, they can release toxic ions that can damage the lung tissue, making dissolution rate an important characteristic that affects lung inflammation. Fibre-shaped materials are more toxic to the lungs compared to spherical shaped nanoparticles of the same chemical composition. In general, cationic nanoparticles are more cytotoxic than neutral or anionic nanoparticles. Finally, surface reactivity correlates well with observed pulmonary inflammation. With all these characteristics affecting different stages of the events leading to pulmonary inflammation, no unifying dose metric could be identified to describe pulmonary inflammation for all nanomaterials, although surface reactivity might be a useful measure. To determine the extent to which the various characteristics influence the induction of pulmonary inflammation, the effect of these characteristics on lung deposition, clearance, and pulmonary response should be systematically evaluated. The results can then be used to facilitate risk assessment by categorizing nanoparticles according to their characteristics.
Collapse
Affiliation(s)
- Hedwig M Braakhuis
- National Institute for Public Health and the Environment (RIVM), PO Box 1, Bilthoven 3720BA, The Netherlands
- Department of Toxicogenomics, Maastricht University, PO Box 616, Maastricht 6200MD, The Netherlands
| | - Margriet VDZ Park
- National Institute for Public Health and the Environment (RIVM), PO Box 1, Bilthoven 3720BA, The Netherlands
| | - Ilse Gosens
- National Institute for Public Health and the Environment (RIVM), PO Box 1, Bilthoven 3720BA, The Netherlands
| | - Wim H De Jong
- National Institute for Public Health and the Environment (RIVM), PO Box 1, Bilthoven 3720BA, The Netherlands
| | - Flemming R Cassee
- National Institute for Public Health and the Environment (RIVM), PO Box 1, Bilthoven 3720BA, The Netherlands
- Institute of Risk Assessment Sciences, Utrecht University, PO Box 80.163, Utrecht 3508TD, The Netherlands
| |
Collapse
|
157
|
Landsiedel R, Ma-Hock L, Hofmann T, Wiemann M, Strauss V, Treumann S, Wohlleben W, Gröters S, Wiench K, van Ravenzwaay B. Application of short-term inhalation studies to assess the inhalation toxicity of nanomaterials. Part Fibre Toxicol 2014; 11:16. [PMID: 24708749 PMCID: PMC4113196 DOI: 10.1186/1743-8977-11-16] [Citation(s) in RCA: 105] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2013] [Accepted: 03/11/2014] [Indexed: 11/29/2022] Open
Abstract
Background A standard short-term inhalation study (STIS) was applied for hazard assessment of 13 metal oxide nanomaterials and micron-scale zinc oxide. Methods Rats were exposed to test material aerosols (ranging from 0.5 to 50 mg/m3) for five consecutive days with 14- or 21-day post-exposure observation. Bronchoalveolar lavage fluid (BALF) and histopathological sections of the entire respiratory tract were examined. Pulmonary deposition and clearance and test material translocation into extra-pulmonary organs were assessed. Results Inhaled nanomaterials were found in the lung, in alveolar macrophages, and in the draining lymph nodes. Polyacrylate-coated silica was also found in the spleen, and both zinc oxides elicited olfactory epithelium necrosis. None of the other nanomaterials was recorded in extra-pulmonary organs. Eight nanomaterials did not elicit pulmonary effects, and their no observed adverse effect concentrations (NOAECs) were at least 10 mg/m3. Five materials (coated nano-TiO2, both ZnO, both CeO2) evoked concentration-dependent transient pulmonary inflammation. Most effects were at least partially reversible during the post-exposure period. Based on the NOAECs that were derived from quantitative parameters, with BALF polymorphonuclear (PMN) neutrophil counts and total protein concentration being most sensitive, or from the severity of histopathological findings, the materials were ranked by increasing toxic potency into 3 grades: lower toxic potency: BaSO4; SiO2.acrylate (by local NOAEC); SiO2.PEG; SiO2.phosphate; SiO2.amino; nano-ZrO2; ZrO2.TODA; ZrO2.acrylate; medium toxic potency: SiO2.naked; higher toxic potency: coated nano-TiO2; nano-CeO2; Al-doped nano-CeO2; micron-scale ZnO; coated nano-ZnO (and SiO2.acrylate by systemic no observed effect concentration (NOEC)). Conclusion The STIS revealed the type of effects of 13 nanomaterials, and micron-scale ZnO, information on their toxic potency, and the location and reversibility of effects. Assessment of lung burden and material translocation provided preliminary biokinetic information. Based upon the study results, the STIS protocol was re-assessed and preliminary suggestions regarding the grouping of nanomaterials for safety assessment were spelled out.
Collapse
Affiliation(s)
- Robert Landsiedel
- Experimental Toxicology and Ecology, BASF SE, 67056 Ludwigshafen, Germany.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
158
|
Staal YCM, van Triel JJ, Maarschalkerweerd TVP, Arts JHE, Duistermaat E, Muijser H, van de Sandt JJM, Kuper CF. Inhaled multiwalled carbon nanotubes modulate the immune response of trimellitic anhydride-induced chemical respiratory allergy in brown Norway rats. Toxicol Pathol 2014; 42:1130-42. [PMID: 24705883 DOI: 10.1177/0192623313519874] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
The interaction between exposure to nanomaterials and existing inflammatory conditions has not been fully established. Multiwalled carbon nanotubes (MWCNT; Nanocyl NC 7000 CAS no. 7782-42-5; count median diameter in atmosphere 61 ± 5 nm) were tested by inhalation in high Immunoglobulin E (IgE)-responding Brown Norway (BN) rats with trimellitic anhydride (TMA)-induced respiratory allergy. The rats were exposed 2 days/week over a 3.5-week period to a low (11 mg/m(3)) or a high (22 mg/m(3)) concentration of MWCNT. Nonallergic animals exposed to MWCNT and unexposed allergic and nonallergic rats served as controls. At the end of the exposure period, the allergic animals were rechallenged with TMA. Histopathological examination of the respiratory tract showed agglomerated/aggregated MWCNT in the lungs and in the lung-draining lymph nodes. Frustrated phagocytosis was observed as incomplete uptake of MWCNT by the alveolar macrophages and clustering of cells around MWCNT. Large MWCNT agglomerates/aggregates were found in granulomas in the allergic rats, suggesting decreased macrophage clearance in allergic rats. In allergic rats, MWCNT exposure decreased serum IgE levels and the number of lymphocytes in bronchoalveolar lavage. In conclusion, MWCNT did not aggravate the acute allergic reaction but modulated the allergy-associated immune response.
Collapse
|
159
|
Pauluhn J. The metrics of MWCNT-induced pulmonary inflammation are dependent on the selected testing regimen. Regul Toxicol Pharmacol 2014; 68:343-52. [DOI: 10.1016/j.yrtph.2014.01.010] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2013] [Revised: 01/21/2014] [Accepted: 01/22/2014] [Indexed: 11/29/2022]
|
160
|
|
161
|
Zhang Y, Bai Y, Jia J, Gao N, Li Y, Zhang R, Jiang G, Yan B. Perturbation of physiological systems by nanoparticles. Chem Soc Rev 2014; 43:3762-809. [PMID: 24647382 DOI: 10.1039/c3cs60338e] [Citation(s) in RCA: 91] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Nanotechnology is having a tremendous impact on our society. However, societal concerns about human safety under nanoparticle exposure may derail the broad application of this promising technology. Nanoparticles may enter the human body via various routes, including respiratory pathways, the digestive tract, skin contact, intravenous injection, and implantation. After absorption, nanoparticles are carried to distal organs by the bloodstream and the lymphatic system. During this process, they interact with biological molecules and perturb physiological systems. Although some ingested or absorbed nanoparticles are eliminated, others remain in the body for a long time. The human body is composed of multiple systems that work together to maintain physiological homeostasis. The unexpected invasion of these systems by nanoparticles disturbs normal cell signaling, impairs cell and organ functions, and may even cause pathological disorders. This review examines the comprehensive health risks of exposure to nanoparticles by discussing how nanoparticles perturb various physiological systems as revealed by animal studies. The potential toxicity of nanoparticles to each physiological system and the implications of disrupting the balance among systems are emphasized.
Collapse
Affiliation(s)
- Yi Zhang
- Key Laboratory for Colloid and Interface Chemistry, Ministry of Education, School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100, China.
| | | | | | | | | | | | | | | |
Collapse
|
162
|
Damaging effects of multi-walled carbon nanotubes on pregnant mice with different pregnancy times. Sci Rep 2014; 4:4352. [PMID: 24619025 PMCID: PMC3950636 DOI: 10.1038/srep04352] [Citation(s) in RCA: 60] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2013] [Accepted: 02/21/2014] [Indexed: 12/26/2022] Open
Abstract
The mechanism by which nanoparticles cross the placental barrier was studied by using isotopic tracers. The abortion rates and other related data were counted and analysed in pregnant mice with different pregnancy times. Results showed that oxidised multi-walled carbon nanotubes (oMWCNTs) crossed the placental barrier and entered the foetus body. The abortion rates in the pregnant mice depended on pregnancy times. The abortion rates in the first-time, second-time and fourth-time pregnant mice were 70%, 40% and 50%, respectively. The maternal body weight gain was inhibited until gestational ages of 13, 10 and 11 d. oMWCNTs decreased the serum progesterone level and increased the serum oestradiol level in a dose- and time-dependent manner. However, this effect decreased with gestational age. The histology and vascular endothelial growth factor/reactive oxygen species content in the placenta showed that oMWCNTs narrowed the blood vessel and decreased the number of blood vessels in the placenta.
Collapse
|
163
|
Gernand JM, Casman EA. A meta-analysis of carbon nanotube pulmonary toxicity studies--how physical dimensions and impurities affect the toxicity of carbon nanotubes. RISK ANALYSIS : AN OFFICIAL PUBLICATION OF THE SOCIETY FOR RISK ANALYSIS 2014; 34:583-597. [PMID: 24024907 DOI: 10.1111/risa.12109] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
This article presents a regression-tree-based meta-analysis of rodent pulmonary toxicity studies of uncoated, nonfunctionalized carbon nanotube (CNT) exposure. The resulting analysis provides quantitative estimates of the contribution of CNT attributes (impurities, physical dimensions, and aggregation) to pulmonary toxicity indicators in bronchoalveolar lavage fluid: neutrophil and macrophage count, and lactate dehydrogenase and total protein concentrations. The method employs classification and regression tree (CART) models, techniques that are relatively insensitive to data defects that impair other types of regression analysis: high dimensionality, nonlinearity, correlated variables, and significant quantities of missing values. Three types of analysis are presented: the RT, the random forest (RF), and a random-forest-based dose-response model. The RT shows the best single model supported by all the data and typically contains a small number of variables. The RF shows how much variance reduction is associated with every variable in the data set. The dose-response model is used to isolate the effects of CNT attributes from the CNT dose, showing the shift in the dose-response caused by the attribute across the measured range of CNT doses. It was found that the CNT attributes that contribute the most to pulmonary toxicity were metallic impurities (cobalt significantly increased observed toxicity, while other impurities had mixed effects), CNT length (negatively correlated with most toxicity indicators), CNT diameter (significantly positively associated with toxicity), and aggregate size (negatively correlated with cell damage indicators and positively correlated with immune response indicators). Increasing CNT N2 -BET-specific surface area decreased toxicity indicators.
Collapse
Affiliation(s)
- Jeremy M Gernand
- Engineering and Public Policy, Carnegie Mellon University, Pittsburgh, PA, USA
| | | |
Collapse
|
164
|
The Significance and Insignificance of Carbon Nanotube-Induced Inflammation. FIBERS 2014. [DOI: 10.3390/fib2010045] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
|
165
|
Zhang Y, Petibone D, Xu Y, Mahmood M, Karmakar A, Casciano D, Ali S, Biris AS. Toxicity and efficacy of carbon nanotubes and graphene: the utility of carbon-based nanoparticles in nanomedicine. Drug Metab Rev 2014; 46:232-46. [PMID: 24506522 DOI: 10.3109/03602532.2014.883406] [Citation(s) in RCA: 103] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Carbon-based nanomaterials have attracted great interest in biomedical applications such as advanced imaging, tissue regeneration, and drug or gene delivery. The toxicity of the carbon nanotubes and graphene remains a debated issue although many toxicological studies have been reported in the scientific community. In this review, we summarize the biological effects of carbon nanotubes and graphene in terms of in vitro and in vivo toxicity, genotoxicity and toxicokinetics. The dose, shape, surface chemistry, exposure route and purity play important roles in the metabolism of carbon-based nanomaterials resulting in differential toxicity. Careful examination of the physico-chemical properties of carbon-based nanomaterials is considered a basic approach to correlate the toxicological response with the unique properties of the carbon nanomaterials. The reactive oxygen species-mediated toxic mechanism of carbon nanotubes has been extensively discussed and strategies, such as surface modification, have been proposed to reduce the toxicity of these materials. Carbon-based nanomaterials used in photothermal therapy, drug delivery and tissue regeneration are also discussed in this review. The toxicokinetics, toxicity and efficacy of carbon-based nanotubes and graphene still need to be investigated further to pave a way for biomedical applications and a better understanding of their potential applications to humans.
Collapse
Affiliation(s)
- Yongbin Zhang
- Nanotechnology Core Facility, Office of Scientific Coordination and
| | | | | | | | | | | | | | | |
Collapse
|
166
|
Købler C, Saber AT, Jacobsen NR, Wallin H, Vogel U, Qvortrup K, Mølhave K. FIB-SEM imaging of carbon nanotubes in mouse lung tissue. Anal Bioanal Chem 2014; 406:3863-73. [PMID: 24448971 PMCID: PMC4039996 DOI: 10.1007/s00216-013-7566-x] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2013] [Revised: 12/03/2013] [Accepted: 12/09/2013] [Indexed: 11/29/2022]
Abstract
Ultrastructural characterisation is important for understanding carbon nanotube (CNT) toxicity and how the CNTs interact with cells and tissues. The standard method for this involves using transmission electron microscopy (TEM). However, in particular, the sample preparation, using a microtome to cut thin sample sections for TEM, can be challenging for investigation of regions with agglomerations of large and stiff CNTs because the CNTs cut with difficulty. As a consequence, the sectioning diamond knife may be damaged and the uncut CNTs are left protruding from the embedded block surface excluding them from TEM analysis. To provide an alternative to ultramicrotomy and subsequent TEM imaging, we studied focused ion beam scanning electron microscopy (FIB-SEM) of CNTs in the lungs of mice, and we evaluated the applicability of the method compared to TEM. FIB-SEM can provide serial section volume imaging not easily obtained with TEM, but it is time-consuming to locate CNTs in the tissue. We demonstrate that protruding CNTs after ultramicrotomy can be used to locate the region of interest, and we present FIB-SEM images of CNTs in lung tissue. FIB-SEM imaging was applied to lung tissue from mice which had been intratracheally instilled with two different multiwalled CNTs; one being short and thin, and the other longer and thicker. FIB-SEM was found to be most suitable for detection of the large CNTs (Ø ca. 70 nm), and to be well suited for studying CNT agglomerates in biological samples which is challenging using standard TEM techniques.
Collapse
Affiliation(s)
- Carsten Købler
- DTU Nanotech, Technical University of Denmark, Ørsteds Plads 345E, 2800, Kgs. Lyngby, Denmark
| | | | | | | | | | | | | |
Collapse
|
167
|
Cao Y, Jacobsen NR, Danielsen PH, Lenz AG, Stoeger T, Loft S, Wallin H, Roursgaard M, Mikkelsen L, Møller P. Vascular Effects of Multiwalled Carbon Nanotubes in Dyslipidemic ApoE−/− Mice and Cultured Endothelial Cells. Toxicol Sci 2014; 138:104-16. [DOI: 10.1093/toxsci/kft328] [Citation(s) in RCA: 85] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023] Open
|
168
|
Hedmer M, Isaxon C, Nilsson PT, Ludvigsson L, Messing ME, Genberg J, Skaug V, Bohgard M, Tinnerberg H, Pagels JH. Exposure and emission measurements during production, purification, and functionalization of arc-discharge-produced multi-walled carbon nanotubes. ACTA ACUST UNITED AC 2014; 58:355-79. [PMID: 24389082 DOI: 10.1093/annhyg/met072] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
BACKGROUND The production and use of carbon nanotubes (CNTs) is rapidly growing. With increased production, there is potential that the number of occupational exposed workers will rapidly increase. Toxicological studies on rats have shown effects in the lungs, e.g., inflammation, granuloma formation, and fibrosis after repeated inhalation exposure to some forms of multi-walled CNTs (MWCNTs). Still, when it comes to health effects, it is unknown which dose metric is most relevant. Limited exposure data for CNTs exist today and no legally enforced occupational exposure limits are yet established. The aim of this work was to quantify the occupational exposures and emissions during arc discharge production, purification, and functionalization of MWCNTs. The CNT material handled typically had a mean length <5 μm. Since most of the collected airborne CNTs did not fulfil the World Health Organization fibre dimensions (79% of the counted CNT-containing particles) and since no microscopy-based method for counting of CNTs exists, we decided to count all particle that contained CNTs. To investigate correlations between the used exposure metrics, Pearson correlation coefficient was used. METHODS Exposure measurements were performed at a small-scale producer of MWCNTs and respirable fractions of dust concentrations, elemental carbon (EC) concentrations, and number concentrations of CNT-containing particles were measured in the workers' breathing zones with filter-based methods during work. Additionally, emission measurements near the source were carried out during different work tasks. Respirable dust was gravimetrically determined; EC was analysed with thermal-optical analysis and the number of CNT-containing particles was analysed with scanning electron microscopy. RESULTS For the personal exposure measurements, respirable dust ranged between <73 and 93 μg m(-3), EC ranged between <0.08 and 7.4 μg C m(-3), and number concentration of CNT-containing particles ranged between 0.04 and 2.0 cm(-3). For the emission measurements, respirable dust ranged between <2800 and 6800 μg m(-3), EC ranged between 0.05 and 550 μg C m(-3), and number concentration of CNT-containing particles ranged between <0.20 and 11cm(-3). CONCLUSIONS The highest exposure to CNTs occurred during production of CNTs. The highest emitted number concentration of CNT-containing particles occurred in the sieving, mechanical work-up, pouring, weighing, and packaging of CNT powder during the production stage. To be able to quantify exposures and emissions of CNTs, a selective and sensitive method is needed. Limitations with measuring EC and respirable dust are that these exposure metrics do not measure CNTs specifically. Only filter-based methods with electron microscopy analysis are, to date, selective and sensitive enough. This study showed that counting of CNT-containing particles is the method that fulfils those criteria and is therefore the method recommended for future quantification of CNT exposures. However, CNTs could be highly toxic not only because of their length but also because they could contain, for example transition metals and polycyclic aromatic hydrocarbons, or have surface defects. Lack of standardized counting criteria for CNTs to be applied at the electron microscopy analysis is a limiting factor, which makes it difficult to compare exposure data from different studies.
Collapse
Affiliation(s)
- Maria Hedmer
- 1. Division of Occupational and Environmental Medicine, Department of Laboratory Medicine, Lund University, PO Box 118, SE-22100 Lund, Sweden
| | | | | | | | | | | | | | | | | | | |
Collapse
|
169
|
Thompson EA, Sayers BC, Glista-Baker EE, Shipkowski KA, Taylor AJ, Bonner JC. Innate Immune Responses to Nanoparticle Exposure in the Lung. ACTA ACUST UNITED AC 2014; 1:150-156. [PMID: 26000239 DOI: 10.7178/jeit.23] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
The nanotechnology revolution offers enormous societal and economic benefits for innovation in the fields of engineering, electronics, and medicine. Nevertheless, evidence from rodent studies show that biopersistent engineered nanomaterials (ENMs) stimulate immune, inflammatory, and fibroproliferative responses in the lung, suggesting possible risks for lung diseases or systemic immune disorders as a consequence of occupational, environmental, or consumer exposure. Due to their nanoscale dimensions and increased surface area per unit mass, ENMs have a much greater potential to reach the distal regions of the lung and generate ROS. High aspect ratio ENMs (e.g., nanotubes, nanofibers) activate inflammasomes in macrophages, triggering IL-1β release and neutrophilic infiltration into the lungs. Moreover, some ENMs alter allergen-induced eosinophilic inflammation by immunostimulation, immunosuppression, or modulating the balance between Th1, Th2, and Th17 cells, thereby influencing the nature of the inflammatory response. ENMs also migrate from the lungs across epithelial, endothelial, or mesothelial barriers to stimulate or suppress systemic immune responses.
Collapse
Affiliation(s)
- Elizabeth A Thompson
- Department of Environmental and Molecular Toxicology, North Carolina State University, Raleigh, North Carolina, USA
| | - Brian C Sayers
- Department of Environmental and Molecular Toxicology, North Carolina State University, Raleigh, North Carolina, USA
| | - Ellen E Glista-Baker
- Department of Environmental and Molecular Toxicology, North Carolina State University, Raleigh, North Carolina, USA
| | - Kelly A Shipkowski
- Department of Environmental and Molecular Toxicology, North Carolina State University, Raleigh, North Carolina, USA
| | - Alexia J Taylor
- Department of Environmental and Molecular Toxicology, North Carolina State University, Raleigh, North Carolina, USA
| | - James C Bonner
- Department of Environmental and Molecular Toxicology, North Carolina State University, Raleigh, North Carolina, USA
| |
Collapse
|
170
|
Jiang L, Kondo A, Shigeta M, Endoh S, Uejima M, Ogura I, Naito M. Evaluation of particles released from single-wall carbon nanotube/polymer composites with or without thermal aging by an accelerated abrasion test. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2014; 11:658-664. [PMID: 24628695 DOI: 10.1080/15459624.2014.902953] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
To provide data required for assessing the environmental health and safety risks of nanocomposites, abrasion-induced particle release from single-wall carbon nanotube (SWCNT)/polymer composites with or without thermal aging were evaluated by a shot blast system. First, overall composite weight loss (i.e., overall particle release) as a result of shot blasting was measured. Incorporating 5 wt% SWCNTs in polystyrene (PS) matrix was observed to reduce overall particle release by approximately 30% compared with pure PS. Heat treatment of the 5 wt% SWCNT/PS composites at 100°C for 10 days induced very slight change in overall particle release due to shot blasting. However, heat treatment at 350°C for 1 hr greatly deteriorated the abrasion resistance of the composites, enhancing overall particle release. Second, to verify the existence and form of SWCNTs released from the composites, released particles were observed by electron microscopy. Micron-sized particles with protruding SWCNTs and submicron-sized SWCNT clusters were observed in the particles released from the composites. Heat treatment of the composites at 350°C for 1 hr enhanced SWCNT release, which mainly formed clusters or rope-like bundles.
Collapse
Affiliation(s)
- Lin Jiang
- a Joining and Welding Research Institute , Osaka University , Osaka , Japan
| | | | | | | | | | | | | |
Collapse
|
171
|
Sauer UG, Vogel S, Aumann A, Hess A, Kolle SN, Ma-Hock L, Wohlleben W, Dammann M, Strauss V, Treumann S, Gröters S, Wiench K, van Ravenzwaay B, Landsiedel R. Applicability of rat precision-cut lung slices in evaluating nanomaterial cytotoxicity, apoptosis, oxidative stress, and inflammation. Toxicol Appl Pharmacol 2013; 276:1-20. [PMID: 24382512 DOI: 10.1016/j.taap.2013.12.017] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2013] [Revised: 12/04/2013] [Accepted: 12/19/2013] [Indexed: 01/22/2023]
Abstract
The applicability of rat precision-cut lung slices (PCLuS) in detecting nanomaterial (NM) toxicity to the respiratory tract was investigated evaluating sixteen OECD reference NMs (TiO₂, ZnO, CeO₂, SiO₂, Ag, multi-walled carbon nanotubes (MWCNTs)). Upon 24-hour test substance exposure, the PCLuS system was able to detect early events of NM toxicity: total protein, reduction in mitochondrial activity, caspase-3/-7 activation, glutathione depletion/increase, cytokine induction, and histopathological evaluation. Ion shedding NMS (ZnO and Ag) induced severe tissue destruction detected by the loss of total protein. Two anatase TiO₂ NMs, CeO₂ NMs, and two MWCNT caused significant (determined by trend analysis) cytotoxicity in the WST-1 assay. At non-cytotoxic concentrations, different TiO₂ NMs and one MWCNT increased GSH levels, presumably a defense response to reactive oxygen species, and these substances further induced a variety of cytokines. One of the SiO₂ NMs increased caspase-3/-7 activities at non-cytotoxic levels, and one rutile TiO₂ only induced cytokines. Investigating these effects is, however, not sufficient to predict apical effects found in vivo. Reproducibility of test substance measurements was not fully satisfactory, especially in the GSH and cytokine assays. Effects were frequently observed in negative controls pointing to tissue slice vulnerability even though prepared and handled with utmost care. Comparisons of the effects observed in the PCLuS to in vivo effects reveal some concordances for the metal oxide NMs, but less so for the MWCNT. The highest effective dosages, however, exceeded those reported for rat short-term inhalation studies. To become applicable for NM testing, the PCLuS system requires test protocol optimization.
Collapse
Affiliation(s)
- Ursula G Sauer
- Scientific Consultancy - Animal Welfare, Neubiberg, Germany
| | - Sandra Vogel
- Experimental Toxicology and Ecology, BASF SE, Ludwigshafen, Germany; Product Stewardship Water Solutions, BASF SE, Ludwigshafen, Germany
| | - Alexandra Aumann
- Experimental Toxicology and Ecology, BASF SE, Ludwigshafen, Germany
| | - Annemarie Hess
- Experimental Toxicology and Ecology, BASF SE, Ludwigshafen, Germany
| | - Susanne N Kolle
- Experimental Toxicology and Ecology, BASF SE, Ludwigshafen, Germany
| | - Lan Ma-Hock
- Experimental Toxicology and Ecology, BASF SE, Ludwigshafen, Germany
| | - Wendel Wohlleben
- Experimental Toxicology and Ecology, BASF SE, Ludwigshafen, Germany; Material Physics, BASF SE, Ludwigshafen, Germany
| | - Martina Dammann
- Experimental Toxicology and Ecology, BASF SE, Ludwigshafen, Germany
| | - Volker Strauss
- Experimental Toxicology and Ecology, BASF SE, Ludwigshafen, Germany
| | - Silke Treumann
- Experimental Toxicology and Ecology, BASF SE, Ludwigshafen, Germany
| | - Sibylle Gröters
- Experimental Toxicology and Ecology, BASF SE, Ludwigshafen, Germany
| | | | | | - Robert Landsiedel
- Experimental Toxicology and Ecology, BASF SE, Ludwigshafen, Germany.
| |
Collapse
|
172
|
Ma-Hock L, Farias PMA, Hofmann T, Andrade ACDS, Silva JN, Arnaud TMS, Wohlleben W, Strauss V, Treumann S, Chaves CR, Gröters S, Landsiedel R, van Ravenzwaay B. Short term inhalation toxicity of a liquid aerosol of glutaraldehyde-coated CdS/Cd(OH)2 core shell quantum dots in rats. Toxicol Lett 2013; 225:20-6. [PMID: 24296008 DOI: 10.1016/j.toxlet.2013.11.007] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2013] [Revised: 11/04/2013] [Accepted: 11/08/2013] [Indexed: 12/29/2022]
Abstract
Quantum dots exhibit extraordinary optical and mechanical properties, and the number of their applications is increasing. In order to investigate a possible effect of coating on the inhalation toxicity of previously tested non-coated CdS/Cd(OH)2 quantum dots and translocation of these very small particles from the lungs, rats were exposed to coated quantum dots or CdCl2 aerosol (since Cd(2+) was present as impurity), 6h/d for 5 consecutive days. Cd content was determined in organs and excreta after the end of exposure and three weeks thereafter. Toxicity was determined by examination of broncho-alveolar lavage fluid and microscopic evaluation of the entire respiratory tract. There was no evidence for translocation of particles from the respiratory tract. Evidence of a minimal inflammatory process was observed by examination of broncho-alveolar lavage fluid. Microscopically, minimal to mild epithelial alteration was seen in the larynx. The effects observed with coated quantum dots, non-coated quantum dots and CdCl2 were comparable, indicating that quantum dots elicited no significant effects beyond the toxicity of the Cd(2+) ion itself. Compared to other compounds with larger particle size tested at similarly low concentrations, quantum dots caused much less pronounced toxicological effects. Therefore, the present data show that small particle sizes with corresponding high surfaces are not the only factor triggering the toxic response or translocation.
Collapse
Affiliation(s)
- L Ma-Hock
- BASF SE, Experimental Toxicology and Ecology, 67056 Ludwigshafen, Germany; Departament of Pharmaceutical Sciences; Federal University of Pernambuco (UFPE), 50670-901 Recife, Brazil
| | - P M A Farias
- Research Group on Nanostructures and Biological Interfaces; Federal University of Pernambuco (UFPE), 50670-901 Recife, Brazil; Graduate Program on Material Sciences; Federal University of Pernambuco (UFPE), 50670-901 Recife, Brazil; Departament of Pharmaceutical Sciences; Federal University of Pernambuco (UFPE), 50670-901 Recife, Brazil
| | - T Hofmann
- BASF SE, Experimental Toxicology and Ecology, 67056 Ludwigshafen, Germany; Departament of Pharmaceutical Sciences; Federal University of Pernambuco (UFPE), 50670-901 Recife, Brazil
| | - A C D S Andrade
- Research Group on Nanostructures and Biological Interfaces; Federal University of Pernambuco (UFPE), 50670-901 Recife, Brazil; Graduate Program on Material Sciences; Federal University of Pernambuco (UFPE), 50670-901 Recife, Brazil; Departament of Pharmaceutical Sciences; Federal University of Pernambuco (UFPE), 50670-901 Recife, Brazil
| | - J N Silva
- Research Group on Nanostructures and Biological Interfaces; Federal University of Pernambuco (UFPE), 50670-901 Recife, Brazil; Graduate Program on Material Sciences; Federal University of Pernambuco (UFPE), 50670-901 Recife, Brazil; Departament of Pharmaceutical Sciences; Federal University of Pernambuco (UFPE), 50670-901 Recife, Brazil
| | - T M S Arnaud
- Research Group on Nanostructures and Biological Interfaces; Federal University of Pernambuco (UFPE), 50670-901 Recife, Brazil; Graduate Program on Material Sciences; Federal University of Pernambuco (UFPE), 50670-901 Recife, Brazil; Departament of Pharmaceutical Sciences; Federal University of Pernambuco (UFPE), 50670-901 Recife, Brazil
| | - W Wohlleben
- BASF SE, Experimental Toxicology and Ecology, 67056 Ludwigshafen, Germany; BASF SE, Material Physics, 67056 Ludwigshafen, Germany; Departament of Pharmaceutical Sciences; Federal University of Pernambuco (UFPE), 50670-901 Recife, Brazil
| | - V Strauss
- BASF SE, Experimental Toxicology and Ecology, 67056 Ludwigshafen, Germany; Departament of Pharmaceutical Sciences; Federal University of Pernambuco (UFPE), 50670-901 Recife, Brazil
| | - S Treumann
- BASF SE, Experimental Toxicology and Ecology, 67056 Ludwigshafen, Germany; Departament of Pharmaceutical Sciences; Federal University of Pernambuco (UFPE), 50670-901 Recife, Brazil
| | - C R Chaves
- Research Group on Nanostructures and Biological Interfaces; Federal University of Pernambuco (UFPE), 50670-901 Recife, Brazil; Graduate Program on Material Sciences; Federal University of Pernambuco (UFPE), 50670-901 Recife, Brazil; Departament of Pharmaceutical Sciences; Federal University of Pernambuco (UFPE), 50670-901 Recife, Brazil
| | - S Gröters
- BASF SE, Experimental Toxicology and Ecology, 67056 Ludwigshafen, Germany; Departament of Pharmaceutical Sciences; Federal University of Pernambuco (UFPE), 50670-901 Recife, Brazil
| | - R Landsiedel
- BASF SE, Experimental Toxicology and Ecology, 67056 Ludwigshafen, Germany; Departament of Pharmaceutical Sciences; Federal University of Pernambuco (UFPE), 50670-901 Recife, Brazil
| | - B van Ravenzwaay
- BASF SE, Experimental Toxicology and Ecology, 67056 Ludwigshafen, Germany; Departament of Pharmaceutical Sciences; Federal University of Pernambuco (UFPE), 50670-901 Recife, Brazil.
| |
Collapse
|
173
|
Søs Poulsen S, Jacobsen NR, Labib S, Wu D, Husain M, Williams A, Bøgelund JP, Andersen O, Købler C, Mølhave K, Kyjovska ZO, Saber AT, Wallin H, Yauk CL, Vogel U, Halappanavar S. Transcriptomic analysis reveals novel mechanistic insight into murine biological responses to multi-walled carbon nanotubes in lungs and cultured lung epithelial cells. PLoS One 2013; 8:e80452. [PMID: 24260392 PMCID: PMC3834097 DOI: 10.1371/journal.pone.0080452] [Citation(s) in RCA: 69] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2013] [Accepted: 10/03/2013] [Indexed: 12/22/2022] Open
Abstract
There is great interest in substituting animal work with in vitro experimentation in human health risk assessment; however, there are only few comparisons of in vitro and in vivo biological responses to engineered nanomaterials. We used high-content genomics tools to compare in vivo pulmonary responses of multiwalled carbon nanotubes (MWCNT) to those in vitro in cultured lung epithelial cells (FE1) at the global transcriptomic level. Primary size, surface area and other properties of MWCNT- XNRI -7 (Mitsui7) were characterized using DLS, SEM and TEM. Mice were exposed via a single intratracheal instillation to 18, 54, or 162 μg of Mitsui7/mouse. FE1 cells were incubated with 12.5, 25 and 100 μg/ml of Mitsui7. Tissue and cell samples were collected at 24 hours post-exposure. DNA microarrays were employed to establish mechanistic differences and similarities between the two models. Microarray results were confirmed using gene-specific RT-qPCR. Bronchoalveolar lavage (BAL) fluid was assessed for indications of inflammation in vivo. A strong dose-dependent activation of acute phase and inflammation response was observed in mouse lungs reflective mainly of an inflammatory response as observed in BAL. In vitro, a wide variety of core cellular functions were affected including transcription, cell cycle, and cellular growth and proliferation. Oxidative stress, fibrosis and inflammation processes were altered in both models. Although there were similarities observed between the two models at the pathway-level, the specific genes altered under these pathways were different, suggesting that the underlying mechanisms of responses are different in cells in culture and the lung tissue. Our results suggest that careful consideration should be given in selecting relevant endpoints when substituting animal with in vitro testing.
Collapse
Affiliation(s)
- Sarah Søs Poulsen
- National Research Centre for the Working Environment, Copenhagen, Denmark
- Department of Science, Systems and Models, Roskilde University, Roskilde, Denmark
| | | | - Sarah Labib
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | - Dongmei Wu
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | - Mainul Husain
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | - Andrew Williams
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | | | - Ole Andersen
- Department of Science, Systems and Models, Roskilde University, Roskilde, Denmark
| | - Carsten Købler
- Department of Micro- and Nanotechnology, Technical University of Denmark, Kgs. Lyngby, Denmark
| | - Kristian Mølhave
- Department of Micro- and Nanotechnology, Technical University of Denmark, Kgs. Lyngby, Denmark
| | - Zdenka O. Kyjovska
- National Research Centre for the Working Environment, Copenhagen, Denmark
| | - Anne T. Saber
- National Research Centre for the Working Environment, Copenhagen, Denmark
| | - Håkan Wallin
- National Research Centre for the Working Environment, Copenhagen, Denmark
- Department of Public Health, University of Copenhagen, Copenhagen, Denmark
| | - Carole L. Yauk
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | - Ulla Vogel
- National Research Centre for the Working Environment, Copenhagen, Denmark
- Department of Micro- and Nanotechnology, Technical University of Denmark, Kgs. Lyngby, Denmark
| | - Sabina Halappanavar
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
- * E-mail:
| |
Collapse
|
174
|
Madl AK, Plummer LE, Carosino C, Pinkerton KE. Nanoparticles, lung injury, and the role of oxidant stress. Annu Rev Physiol 2013; 76:447-65. [PMID: 24215442 DOI: 10.1146/annurev-physiol-030212-183735] [Citation(s) in RCA: 93] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
The emergence of engineered nanoscale materials has provided significant advancements in electronic, biomedical, and material science applications. Both engineered nanoparticles and nanoparticles derived from combustion or incidental processes exhibit a range of physical and chemical properties that induce inflammation and oxidative stress in biological systems. Oxidative stress reflects the imbalance between the generation of reactive oxygen species and the biochemical mechanisms to detoxify and repair the damage resulting from reactive intermediates. This review examines current research on incidental and engineered nanoparticles in terms of their health effects on lungs and the mechanisms by which oxidative stress via physicochemical characteristics influences toxicity or biocompatibility. Although oxidative stress has generally been thought of as an adverse biological outcome, this review also briefly discusses some of the potential emerging technologies to use nanoparticle-induced oxidative stress to treat disease in a site-specific fashion.
Collapse
Affiliation(s)
- Amy K Madl
- Center for Health and the Environment, University of California, Davis, California 95616; ,
| | | | | | | |
Collapse
|
175
|
Hougaard KS, Jackson P, Kyjovska ZO, Birkedal RK, De Temmerman PJ, Brunelli A, Verleysen E, Madsen AM, Saber AT, Pojana G, Mast J, Marcomini A, Jensen KA, Wallin H, Szarek J, Mortensen A, Vogel U. Effects of lung exposure to carbon nanotubes on female fertility and pregnancy. A study in mice. Reprod Toxicol 2013; 41:86-97. [DOI: 10.1016/j.reprotox.2013.05.006] [Citation(s) in RCA: 58] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2013] [Revised: 05/15/2013] [Accepted: 05/17/2013] [Indexed: 12/13/2022]
|
176
|
Doudrick K, Corson N, Oberdörster G, Elder A, Herckes P, Halden RU, Westerhoff P. Extraction and quantification of carbon nanotubes in biological matrices with application to rat lung tissue. ACS NANO 2013; 7:8849-56. [PMID: 23992048 PMCID: PMC3908926 DOI: 10.1021/nn403302s] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
Extraction of carbon nanotubes (CNTs) from biological matrices such as rat lung tissue is integral to developing a quantification method for evaluating the environmental and human health exposure and toxicity of CNTs. The ability of various chemical treatment methods, including Solvable (2.5% sodium hydroxide/surfactant mixture), ammonium hydroxide, nitric acid, sulfuric acid, hydrochloric acid, hydrofluoric acid, hydrogen peroxide, and proteinase K, to extract CNTs from rat lung tissue was evaluated. CNTs were quantified using programmed thermal analysis (PTA). Two CNTs were used to represent the lower (500 °C) and upper (800 °C) PTA limit of CNT thermal stability. The recovery efficiency of each of the eight chemical reagents evaluated was found to depend on the ability to (1) minimize oxidation of CNTs, (2) remove interfering background carbon from the rat lung tissue, and (3) separate the solid-phase CNTs from the liquid-phase dissolved tissue via centrifugation. A two-step extraction method using Solvable and proteinase K emerged as the optimal approach, enabling a recovery of 98 ± 15% of a 2.9 ± 0.19 μg CNT loading that was spiked into whole rat lungs. Due to its high yield and applicability to low organ burdens of nanomaterials, this extraction method is particularly well suited for in vivo studies to quantify clearance rates and retained CNTs in lungs and other organs.
Collapse
Affiliation(s)
- Kyle Doudrick
- Arizona State University, School of Sustainable Engineering and the Built Environment, Tempe, AZ 85287-5306
- Corresponding Author –
| | - Nancy Corson
- University of Rochester, School of Medicine and Dentistry, Department of Environmental Medicine, Rochester, NY 14642
| | - Günter Oberdörster
- University of Rochester, School of Medicine and Dentistry, Department of Environmental Medicine, Rochester, NY 14642
| | - Alison Elder
- University of Rochester, School of Medicine and Dentistry, Department of Environmental Medicine, Rochester, NY 14642
| | - Pierre Herckes
- Arizona State University, Department of Chemistry and Biochemistry, Tempe, AZ 85287-1604
| | - Rolf U. Halden
- Arizona State University, School of Sustainable Engineering and the Built Environment, Tempe, AZ 85287-5306
- Arizona State University, Biodesign Institute, Security and Defense Systems Initiative, Center for Environmental Security, Tempe, AZ 85287-5904
| | - Paul Westerhoff
- Arizona State University, School of Sustainable Engineering and the Built Environment, Tempe, AZ 85287-5306
| |
Collapse
|
177
|
Erdely A, Dahm M, Chen BT, Zeidler-Erdely PC, Fernback JE, Birch ME, Evans DE, Kashon ML, Deddens JA, Hulderman T, Bilgesu SA, Battelli L, Schwegler-Berry D, Leonard HD, McKinney W, Frazer DG, Antonini JM, Porter DW, Castranova V, Schubauer-Berigan MK. Carbon nanotube dosimetry: from workplace exposure assessment to inhalation toxicology. Part Fibre Toxicol 2013; 10:53. [PMID: 24144386 PMCID: PMC4015290 DOI: 10.1186/1743-8977-10-53] [Citation(s) in RCA: 108] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2013] [Accepted: 09/20/2013] [Indexed: 12/27/2022] Open
Abstract
Background Dosimetry for toxicology studies involving carbon nanotubes (CNT) is challenging because of a lack of detailed occupational exposure assessments. Therefore, exposure assessment findings, measuring the mass concentration of elemental carbon from personal breathing zone (PBZ) samples, from 8 U.S.-based multi-walled CNT (MWCNT) manufacturers and users were extrapolated to results of an inhalation study in mice. Results Upon analysis, an inhalable elemental carbon mass concentration arithmetic mean of 10.6 μg/m3 (geometric mean 4.21 μg/m3) was found among workers exposed to MWCNT. The concentration equates to a deposited dose of approximately 4.07 μg/d in a human, equivalent to 2 ng/d in the mouse. For MWCNT inhalation, mice were exposed for 19 d with daily depositions of 1970 ng (equivalent to 1000 d of a human exposure; cumulative 76 yr), 197 ng (100 d; 7.6 yr), and 19.7 ng (10 d; 0.76 yr) and harvested at 0, 3, 28, and 84 d post-exposure to assess pulmonary toxicity. The high dose showed cytotoxicity and inflammation that persisted through 84 d after exposure. The middle dose had no polymorphonuclear cell influx with transient cytotoxicity. The low dose was associated with a low grade inflammatory response measured by changes in mRNA expression. Increased inflammatory proteins were present in the lavage fluid at the high and middle dose through 28 d post-exposure. Pathology, including epithelial hyperplasia and peribronchiolar inflammation, was only noted at the high dose. Conclusion These findings showed a limited pulmonary inflammatory potential of MWCNT at levels corresponding to the average inhalable elemental carbon concentrations observed in U.S.-based CNT facilities and estimates suggest considerable years of exposure are necessary for significant pathology to occur at that level.
Collapse
Affiliation(s)
- Aaron Erdely
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Morgantown, WV, USA.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
178
|
Vietti G, Ibouraadaten S, Palmai-Pallag M, Yakoub Y, Bailly C, Fenoglio I, Marbaix E, Lison D, van den Brule S. Towards predicting the lung fibrogenic activity of nanomaterials: experimental validation of an in vitro fibroblast proliferation assay. Part Fibre Toxicol 2013; 10:52. [PMID: 24112397 PMCID: PMC3852297 DOI: 10.1186/1743-8977-10-52] [Citation(s) in RCA: 65] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2013] [Accepted: 09/27/2013] [Indexed: 11/15/2022] Open
Abstract
Background Carbon nanotubes (CNT) can induce lung inflammation and fibrosis in rodents. Several studies have identified the capacity of CNT to stimulate the proliferation of fibroblasts. We developed and validated experimentally here a simple and rapid in vitro assay to evaluate the capacity of a nanomaterial to exert a direct pro-fibrotic effect on fibroblasts. Methods The activity of several multi-wall (MW)CNT samples (NM400, the crushed form of NM400 named NM400c, NM402 and MWCNTg 2400) and asbestos (crocidolite) was investigated in vitro and in vivo. The proliferative response to MWCNT was assessed on mouse primary lung fibroblasts, human fetal lung fibroblasts (HFL-1), mouse embryonic fibroblasts (BALB-3T3) and mouse lung fibroblasts (MLg) by using different assays (cell counting, WST-1 assay and propidium iodide PI staining) and dispersion media (fetal bovine serum, FBS and bovine serum albumin, BSA). C57BL/6 mice were pharyngeally aspirated with the same materials and lung fibrosis was assessed after 2 months by histopathology, quantification of total collagen lung content and pro-fibrotic cytokines in broncho-alveolar lavage fluid (BALF). Results MWCNT (NM400 and NM402) directly stimulated fibroblast proliferation in vitro in a dose-dependent manner and induced lung fibrosis in vivo. NM400 stimulated the proliferation of all tested fibroblast types, independently of FBS- or BSA- dispersion. Results obtained by WST1 cell activity were confirmed with cell counting and cell cycle (PI staining) assays. Crocidolite also stimulated fibroblast proliferation and induced pulmonary fibrosis, although to a lesser extent than NM400 and NM402. In contrast, shorter CNT (NM400c and MWCNTg 2400) did not induce any fibroblast proliferation or collagen accumulation in vivo, supporting the idea that CNT structure is an important parameter for inducing lung fibrosis. Conclusions In this study, an optimized proliferation assay using BSA as a dispersant, MLg cells as targets and an adaptation of WST-1 as readout was developed. The activity of MWCNT in this test strongly reflects their fibrotic activity in vivo, supporting the predictive value of this in vitro assay in terms of lung fibrosis potential.
Collapse
Affiliation(s)
- Giulia Vietti
- Louvain centre for Toxicology and Applied Pharmacology, Université catholique de Louvain, Avenue E, Mounier, 52 - bte B1,52,12, 1200 Brussels, Belgium.
| | | | | | | | | | | | | | | | | |
Collapse
|
179
|
Lee BW, Kadoya C, Horie M, Mizuguchi Y, Hashiba M, Kambara T, Okada T, Myojo T, Oyabu T, Ogami A, Morimoto Y, Tanaka I, Uchida K, Endoh S, Nakanishi J. Analysis of pulmonary surfactant in rat lungs after intratracheal instillation of short and long multi-walled carbon nanotubes. Inhal Toxicol 2013; 25:609-20. [DOI: 10.3109/08958378.2013.821562] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
180
|
Kasel D, Bradford SA, Simůnek J, Pütz T, Vereecken H, Klumpp E. Limited transport of functionalized multi-walled carbon nanotubes in two natural soils. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2013; 180:152-158. [PMID: 23770315 DOI: 10.1016/j.envpol.2013.05.031] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/08/2013] [Revised: 05/08/2013] [Accepted: 05/16/2013] [Indexed: 06/02/2023]
Abstract
Column experiments were conducted in undisturbed and in repacked soil columns at water contents close to saturation (85-96%) to investigate the transport and retention of functionalized (14)C-labeled multi-walled carbon nanotubes (MWCNT) in two natural soils. Additionally, a field lysimeter experiment was performed to provide long-term information at a larger scale. In all experiments, no breakthrough of MWCNTs was detectable and more than 85% of the applied radioactivity was recovered in the soil profiles. The retention profiles exhibited a hyper-exponential shape with greater retention near the column or lysimeter inlet and were successfully simulated using a numerical model that accounted for depth-dependent retention. In conclusion, results indicated that the soils acted as a strong sink for MWCNTs. Little transport of MWCNTs is therefore likely to occur in the vadose zone, and this implies limited potential for groundwater contamination in the investigated soils.
Collapse
Affiliation(s)
- Daniela Kasel
- Agrosphere Institute (IBG-3), Forschungszentrum Jülich GmbH, 52425 Jülich, Germany.
| | | | | | | | | | | |
Collapse
|
181
|
Du J, Wang S, You H, Zhao X. Understanding the toxicity of carbon nanotubes in the environment is crucial to the control of nanomaterials in producing and processing and the assessment of health risk for human: a review. ENVIRONMENTAL TOXICOLOGY AND PHARMACOLOGY 2013; 36:451-462. [PMID: 23770455 DOI: 10.1016/j.etap.2013.05.007] [Citation(s) in RCA: 99] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/14/2013] [Revised: 05/10/2013] [Accepted: 05/17/2013] [Indexed: 05/23/2023]
Abstract
With the development and application of carbon nanotubes (CNTs), the potential hazards of CNTs to biological systems and the environment are getting more and more attention. This review evaluated the effects of physicochemical properties of CNTs on toxicity and summarized the advances on the mechanism of CNTs toxicity. We also proposed the possible hazards associated with CNTs and harmful effects resulting from exposure of aquatic animals, bacteria and higher plants to CNTs in vitro and in vivo. The current knowledge and gaps on CNTs were outlined as a potential problem for the environment and human health. The current research gaps on CNTs toxicity were identified and the further studying focus was proposed, too. This essay concluded with a set of recommendations for the advancement of understanding of the role of CNTs and future challenges in environmental and ecotoxicological research.
Collapse
Affiliation(s)
- Jia Du
- State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin 150090, PR China.
| | - Shutao Wang
- State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin 150090, PR China.
| | - Hong You
- State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin 150090, PR China.
| | - Xuesong Zhao
- State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin 150090, PR China.
| |
Collapse
|
182
|
Nel AE, Nasser E, Godwin H, Avery D, Bahadori T, Bergeson L, Beryt E, Bonner JC, Boverhof D, Carter J, Castranova V, Deshazo JR, Hussain SM, Kane AB, Klaessig F, Kuempel E, Lafranconi M, Landsiedel R, Malloy T, Miller MB, Morris J, Moss K, Oberdorster G, Pinkerton K, Pleus RC, Shatkin JA, Thomas R, Tolaymat T, Wang A, Wong J. A multi-stakeholder perspective on the use of alternative test strategies for nanomaterial safety assessment. ACS NANO 2013; 7:6422-33. [PMID: 23924032 PMCID: PMC4004078 DOI: 10.1021/nn4037927] [Citation(s) in RCA: 56] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
There has been a conceptual shift in toxicological studies from describing what happens to explaining how the adverse outcome occurs, thereby enabling a deeper and improved understanding of how biomolecular and mechanistic profiling can inform hazard identification and improve risk assessment. Compared to traditional toxicology methods, which have a heavy reliance on animals, new approaches to generate toxicological data are becoming available for the safety assessment of chemicals, including high-throughput and high-content screening (HTS, HCS). With the emergence of nanotechnology, the exponential increase in the total number of engineered nanomaterials (ENMs) in research, development, and commercialization requires a robust scientific approach to screen ENM safety in humans and the environment rapidly and efficiently. Spurred by the developments in chemical testing, a promising new toxicological paradigm for ENMs is to use alternative test strategies (ATS), which reduce reliance on animal testing through the use of in vitro and in silico methods such as HTS, HCS, and computational modeling. Furthermore, this allows for the comparative analysis of large numbers of ENMs simultaneously and for hazard assessment at various stages of the product development process and overall life cycle. Using carbon nanotubes as a case study, a workshop bringing together national and international leaders from government, industry, and academia was convened at the University of California, Los Angeles, to discuss the utility of ATS for decision-making analyses of ENMs. After lively discussions, a short list of generally shared viewpoints on this topic was generated, including a general view that ATS approaches for ENMs can significantly benefit chemical safety analysis.
Collapse
Affiliation(s)
- Andre E Nel
- Department of Medicine, Division of NanoMedicine, University of California Center for Environmental Implications of Nanotechnology, University of California, Los Angeles, California 90095, United States.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
183
|
Mercer RR, Scabilloni JF, Hubbs AF, Battelli LA, McKinney W, Friend S, Wolfarth MG, Andrew M, Castranova V, Porter DW. Distribution and fibrotic response following inhalation exposure to multi-walled carbon nanotubes. Part Fibre Toxicol 2013; 10:33. [PMID: 23895460 PMCID: PMC3733770 DOI: 10.1186/1743-8977-10-33] [Citation(s) in RCA: 130] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2013] [Accepted: 07/22/2013] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Prior studies have demonstrated a rapid and progressive acute phase response to bolus aspiration of multi-walled carbon nanotubes (MWCNTs). In this study we sought to test the hypothesis that inhalation exposure to MWCNT produces a fibrotic response and that the response is chronically persistent. To address the hypothesis that inhaled MWCNTs cause persistent morphologic changes, male C57BL/6 J mice were exposed in a whole-body inhalation system to a MWCNT aerosol and the fibrotic response in the alveolar region examined at up to 336 days after termination of exposure. METHODS Inhalation exposure was to a 5 mg/m3 MWCNT aerosol for 5 hours/day for 12 days (4 times/week for 3 weeks). At the end of inhalation exposures, lungs were either lavaged for analysis of bronchoalveolar lavage (BAL) or preserved by vascular perfusion of fixative while inflated with air at 1, 14, 84, 168 and 336 days post inhalation exposure. Separate, clean-air control groups were also studied. Light microscopy, enhanced darkfield microscopy and field emission electron microscopy (FESEM) of tissue sections were used to analyze the distribution of lung burden following inhalation exposure. Morphometric measurements of Sirius Red staining for fibrillar collagen were used to assess the connective tissue response. Serial section analysis of enhanced darkfield microscope images was used to examine the redistribution of MWCNT fibers within the lungs during the post-exposure period. RESULTS At day 1 post-exposure 84 ± 3 and 16 ± 2 percent of the lung burden (Mean ± S.E., N = 5) were in the alveolar and airway regions, respectively. Initial distribution within the alveolar region was 56 ± 5, 7 ± 4 and 20 ± 3 percent of lung burden in alveolar macrophages, alveolar airspaces and alveolar tissue, respectively. Clearance reduced the alveolar macrophage burden of MWCNTs by 35 percent between 1 and 168 days post-exposure, while the content of MWCNTs in the alveolar tissue increased by 63 percent. Large MWCNT structures containing greater than 4 fibers were 53.6 percent of the initial lung burden and accounted for the majority of the decline with clearance, while lung burden of singlet MWCNT was essentially unchanged. The mean linear intercept of alveolar airspace, a measure of the expansion of the lungs, was not significantly different between groups. Pulmonary inflammation and damage, measured as the number of polymorphnuclear leukocytes (PMNs) or lactate dehydrogenase activity (LDH) and albumin in BAL, increased rapidly (1 day post) after inhalation of MWCNTs and declined slowly with time post-exposure. The fibrillar collagen in the alveolar region of MWCNT-exposed mice demonstrated a progressive increase in thickness over time (0.17 ± 0.02, 0.22 ± 0.02, 0.26 ± 0.03, 0.25 ± 0.02 and 0.29 ± 0.01 microns for 1, 14, 84, 168 and 336 days post-exposure) and was significantly different from clean-air controls (0.16 ± 0.02) at 84 and (0.15 ± 0.02) at 336 days post-exposure. CONCLUSIONS Despite the relatively low fraction of the lung burden being delivered to the alveolar tissue, the average thickness of connective tissue in the alveolar region increased by 70% in the 336 days after inhalation exposure. These results demonstrate that inhaled MWCNTs deposit and are retained within the alveolar tissue where they produce a progressive and persistent fibrotic response up to 336 days post-exposure.
Collapse
Affiliation(s)
- Robert R Mercer
- Health Effects Laboratory Division, NIOSH, MS 2015, 1095 Willowdale Drive, Morgantown, WV, USA
- Department of Physiology and Pharmacology, West Virginia University, Morgantown, WV, USA
| | - James F Scabilloni
- Health Effects Laboratory Division, NIOSH, MS 2015, 1095 Willowdale Drive, Morgantown, WV, USA
| | - Ann F Hubbs
- Health Effects Laboratory Division, NIOSH, MS 2015, 1095 Willowdale Drive, Morgantown, WV, USA
| | - Lori A Battelli
- Health Effects Laboratory Division, NIOSH, MS 2015, 1095 Willowdale Drive, Morgantown, WV, USA
| | - Walter McKinney
- Health Effects Laboratory Division, NIOSH, MS 2015, 1095 Willowdale Drive, Morgantown, WV, USA
| | - Sherri Friend
- Health Effects Laboratory Division, NIOSH, MS 2015, 1095 Willowdale Drive, Morgantown, WV, USA
| | - Michael G Wolfarth
- Health Effects Laboratory Division, NIOSH, MS 2015, 1095 Willowdale Drive, Morgantown, WV, USA
| | - Michael Andrew
- Health Effects Laboratory Division, NIOSH, MS 2015, 1095 Willowdale Drive, Morgantown, WV, USA
| | - Vincent Castranova
- Health Effects Laboratory Division, NIOSH, MS 2015, 1095 Willowdale Drive, Morgantown, WV, USA
| | - Dale W Porter
- Health Effects Laboratory Division, NIOSH, MS 2015, 1095 Willowdale Drive, Morgantown, WV, USA
- Department of Physiology and Pharmacology, West Virginia University, Morgantown, WV, USA
| |
Collapse
|
184
|
Umeda Y, Kasai T, Saito M, Kondo H, Toya T, Aiso S, Okuda H, Nishizawa T, Fukushima S. Two-week Toxicity of Multi-walled Carbon Nanotubes by Whole-body Inhalation Exposure in Rats. J Toxicol Pathol 2013; 26:131-40. [PMID: 23914055 PMCID: PMC3695335 DOI: 10.1293/tox.26.131] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2012] [Accepted: 01/04/2013] [Indexed: 11/19/2022] Open
Abstract
To evaluate pulmonary toxicity of multi-walled carbon nanotubes (MWCNTs), F344 rats of
both sexes were exposed by inhalation to 0.2, 1 or 5 mg/m3 MWCNT aerosol for 6
h/day, 5 days/week for 2 weeks using a whole-body exposure system. At the end of the
2-week exposure period, one-half of the rats were necropsied, and at the end of an
additional 4-week postexposure period, the remaining rats were necropsied. MWCNTs were
deposited in the lungs of all MWCNT-exposed groups and mostly remained in the lungs
throughout the 4-week postexposure period. Granulomatous changes in the lung were found in
the rats exposed to 5 mg/m3 MWCNTs, and these changes were slightly aggravated
at the end of the 4-week postexposure period. In the bronchoalveolar lavage fluid (BALF),
the numbers of neutrophils, percentages of bi- and multinucleated alveolar macrophages,
levels of ALP activity and concentrations of total protein and albumin were elevated in
the rats exposed to 1 and 5 mg/m3 MWCNTs. At the end of the 4-week postexposure
period, the values of the BALF parameters tended to remain elevated. In addition, goblet
cell hyperplasias in the nasal cavity and nasopharynx were observed in the rats exposed to
1 and 5 mg/m3 MWCNTs, but these lesions had largely regressed by the end of the
postexposure period. Based on the histopathological and inflammatory changes, the
no-observed-adverse-effect level (NOAEL) for inhalation of MWCNTs for 2 weeks was 0.2
mg/m3.
Collapse
Affiliation(s)
- Yumi Umeda
- Japan Bioassay Research Center, Japan Industrial Safety and Health Association, 2445 Hirasawa, Hadano, Kanagawa 257-0015, Japan
| | | | | | | | | | | | | | | | | |
Collapse
|
185
|
Toward a comprehensive framework for nanomaterials: An interdisciplinary assessment of the current Environmental Health and Safety Regulation regarding the handling of carbon nanotubes. ACS CHEMICAL HEALTH & SAFETY 2013. [DOI: 10.1016/j.jchas.2013.02.014] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
186
|
|
187
|
Chuang SM, Lee YH, Liang RY, Roam GD, Zeng ZM, Tu HF, Wang SK, Chueh PJ. Extensive evaluations of the cytotoxic effects of gold nanoparticles. Biochim Biophys Acta Gen Subj 2013; 1830:4960-73. [PMID: 23811345 DOI: 10.1016/j.bbagen.2013.06.025] [Citation(s) in RCA: 73] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2012] [Revised: 05/06/2013] [Accepted: 06/14/2013] [Indexed: 12/16/2022]
Abstract
BACKGROUND Many in vitro studies have revealed that the interference of dye molecules in traditional nanoparticle cytotoxicity assays results in controversial conclusions. The aim of this study is to establish an extensive and systematic method for evaluating biological effects of gold nanoparticles in mammalian cell lines. METHODS We establish the cell-impedance measurement system, a label-free, real-time cell monitoring platform that measures electrical impedance, displaying results as cell index values, in a variety of mammalian cell lines. Cytotoxic effects of gold nanoparticles are also evaluated with traditional in vitro assays. RESULTS Among the six cell lines, gold nanoparticles induce a dose-dependent suppression of cell growth with different levels of severity and the suppressive effect of gold nanoparticles was indirectly associated with their sizes and cellular uptake. Mechanistic studies revealed that the action of gold nanoparticles is mediated by apoptosis induction or cell cycle delay, depending on cell type and cellular context. Although redox signaling is often linked to the toxicity of nanoparticles, in this study, we found that gold nanoparticle-mediated reactive oxygen species generation was not sustained to notably modulate proteins involved in antioxidative defense system. CONCLUSION The cell-impedance measurement system, a dye-free, real-time screening platform, provides a reliable analysis for monitoring gold nanoparticle cytotoxicity in a variety of mammalian cell lines. Furthermore, gold nanoparticles induce cellular signaling and several sets of gene expression to modulate cellular physical processes. GENERAL SIGNIFICANCE The systematic approach, such as cell-impedance measurement, analyzing the toxicology of nanomaterials offers convincing evidence of the cytotoxicity of gold nanomaterials.
Collapse
Affiliation(s)
- Show-Mei Chuang
- Institute of Biomedical Sciences, National Chung Hsing University, Taichung, Taiwan
| | | | | | | | | | | | | | | |
Collapse
|
188
|
Thorley AJ, Tetley TD. New perspectives in nanomedicine. Pharmacol Ther 2013; 140:176-85. [PMID: 23811125 DOI: 10.1016/j.pharmthera.2013.06.008] [Citation(s) in RCA: 109] [Impact Index Per Article: 9.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2013] [Accepted: 06/06/2013] [Indexed: 12/31/2022]
Abstract
Recent advances in nanotechnology have revolutionised all aspects of life, from engineering to cosmetics. One of the most exciting areas of development is that of nanomedicine. Due to their size (less than 100nm in one aspect), nanoparticles exhibit properties that are unlike that of the same material in bulk size. These unique properties are being exploited to create new diagnostics and therapeutics for application in a broad spectrum of organ systems. Indeed, nanoparticles are already being developed as effective carriers of drugs to target regions of the body that were previously hard to access using traditional drug formulation methods. However, in addition to their role as a vehicle for drug delivery, nanoparticles themselves have the potential to have therapeutic benefit. Through manipulation of their elemental composition, size, shape, charge and surface modification or functionalisation it may be possible to target particles to specific organs where they may elicit their therapeutic effect. In this review we will focus on the recent advances in nanotechnology for therapeutic applications with a particular focus on the respiratory system, cancer and vaccinations. In addition we will also address developments in the field of nanotoxicology and the need for concomitant studies in to the toxicity of emerging nanotechnologies. It is possible that the very properties that make nanoparticles a desirable technology for therapeutic intervention may also lead to adverse health effects. It is thus important to determine, and appreciate, the fine balance between the efficacy and toxicity of nanomedicine.
Collapse
Affiliation(s)
- Andrew J Thorley
- Lung Cell Biology, National Heart & Lung Institute, Imperial College London, United Kingdom.
| | | |
Collapse
|
189
|
Ma-Hock L, Strauss V, Treumann S, Küttler K, Wohlleben W, Hofmann T, Gröters S, Wiench K, van Ravenzwaay B, Landsiedel R. Comparative inhalation toxicity of multi-wall carbon nanotubes, graphene, graphite nanoplatelets and low surface carbon black. Part Fibre Toxicol 2013; 10:23. [PMID: 23773277 PMCID: PMC3720229 DOI: 10.1186/1743-8977-10-23] [Citation(s) in RCA: 106] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2013] [Accepted: 05/10/2013] [Indexed: 12/14/2022] Open
Abstract
BACKGROUND Carbon nanotubes, graphene, graphite nanoplatelets and carbon black are seemingly chemically identical carbon-based nano-materials with broad technological applications. Carbon nanotubes and carbon black possess different inhalation toxicities, whereas little is known about graphene and graphite nanoplatelets. METHODS In order to compare the inhalation toxicity of the mentioned carbon-based nanomaterials, male Wistar rats were exposed head-nose to atmospheres of the respective materials for 6 hours per day on 5 consecutive days. Target concentrations were 0.1, 0.5, or 2.5 mg/m3 for multi-wall carbon nanotubes and 0.5, 2.5, or 10 mg/m3 for graphene, graphite nanoplatelets and low-surface carbon black. Toxicity was determined after end of exposure and after three-week recovery using broncho-alveolar lavage fluid and microscopic examinations of the entire respiratory tract. RESULTS No adverse effects were observed after inhalation exposure to 10 mg/m3 graphite nanoplatelets or relatively low specific surface area carbon black. Increases of lavage markers indicative for inflammatory processes started at exposure concentration of 0.5 mg/m3 for multi-wall carbon nanotubes and 10 mg/m3 for graphene. Consistent with the changes in lavage fluid, microgranulomas were observed at 2.5 mg/m3 multi-wall carbon nanotubes and 10 mg/m3 graphene. In order to evaluate volumetric loading of the lung as the key parameter driving the toxicity, deposited particle volume was calculated, taking into account different methods to determine the agglomerate density. However, the calculated volumetric load did not correlate to the toxicity, nor did the particle surface burden of the lung. CONCLUSIONS The inhalation toxicity of the investigated carbon-based materials is likely to be a complex interaction of several parameters. Until the properties which govern the toxicity are identified, testing by short-term inhalation is the best option to identify hazardous properties in order to avoid unsafe applications or select safer alternatives for a given application.
Collapse
Affiliation(s)
- Lan Ma-Hock
- Experimental Toxicology and Ecology, BASF SE, 67056 Ludwigshafen, Germany
| | - Volker Strauss
- Experimental Toxicology and Ecology, BASF SE, 67056 Ludwigshafen, Germany
| | - Silke Treumann
- Experimental Toxicology and Ecology, BASF SE, 67056 Ludwigshafen, Germany
| | - Karin Küttler
- Experimental Toxicology and Ecology, BASF SE, 67056 Ludwigshafen, Germany
| | | | - Thomas Hofmann
- Experimental Toxicology and Ecology, BASF SE, 67056 Ludwigshafen, Germany
| | - Sibylle Gröters
- Experimental Toxicology and Ecology, BASF SE, 67056 Ludwigshafen, Germany
| | - Karin Wiench
- Product Safety, BASF SE, 67056 Ludwigshafen, Germany
| | | | - Robert Landsiedel
- Experimental Toxicology and Ecology, BASF SE, 67056 Ludwigshafen, Germany
| |
Collapse
|
190
|
Bonner JC, Silva RM, Taylor AJ, Brown JM, Hilderbrand SC, Castranova V, Porter D, Elder A, Oberdörster G, Harkema JR, Bramble LA, Kavanagh TJ, Botta D, Nel A, Pinkerton KE. Interlaboratory evaluation of rodent pulmonary responses to engineered nanomaterials: the NIEHS Nano GO Consortium. ENVIRONMENTAL HEALTH PERSPECTIVES 2013; 121:676-82. [PMID: 23649427 PMCID: PMC3672912 DOI: 10.1289/ehp.1205693] [Citation(s) in RCA: 84] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/29/2012] [Accepted: 04/01/2013] [Indexed: 05/25/2023]
Abstract
BACKGROUND Engineered nanomaterials (ENMs) have potential benefits, but they also present safety concerns for human health. Interlaboratory studies in rodents using standardized protocols are needed to assess ENM toxicity. METHODS Four laboratories evaluated lung responses in C57BL/6 mice to ENMs delivered by oropharyngeal aspiration (OPA), and three labs evaluated Sprague-Dawley (SD) or Fisher 344 (F344) rats following intratracheal instillation (IT). ENMs tested included three forms of titanium dioxide (TiO2) [anatase/rutile spheres (TiO2-P25), anatase spheres (TiO2-A), and anatase nanobelts (TiO2-NBs)] and three forms of multiwalled carbon nanotubes (MWCNTs) [original (O), purified (P), and carboxylic acid "functionalized" (F)]. One day after treatment, bronchoalveolar lavage fluid was collected to determine differential cell counts, lactate dehydrogenase (LDH), and protein. Lungs were fixed for histopathology. Responses were also examined at 7 days (TiO2 forms) and 21 days (MWCNTs) after treatment. RESULTS TiO2-A, TiO2-P25, and TiO2-NB caused significant neutrophilia in mice at 1 day in three of four labs. TiO2-NB caused neutrophilia in rats at 1 day in two of three labs, and TiO2-P25 and TiO2-A had no significant effect in any of the labs. Inflammation induced by TiO2 in mice and rats resolved by day 7. All MWCNT types caused neutrophilia at 1 day in three of four mouse labs and in all rat labs. Three of four labs observed similar histopathology to O-MWCNTs and TiO2-NBs in mice. CONCLUSIONS ENMs produced similar patterns of neutrophilia and pathology in rats and mice. Although interlaboratory variability was found in the degree of neutrophilia caused by the three types of TiO2 nanoparticles, similar findings of relative potency for the three types of MWCNTs were found across all laboratories, thus providing greater confidence in these interlaboratory comparisons.
Collapse
Affiliation(s)
- James C Bonner
- Department of Environmental and Molecular Toxicology, North Carolina State University, Raleigh, North Carolina, USA
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
191
|
Zuo G, Kang SG, Xiu P, Zhao Y, Zhou R. Interactions between proteins and carbon-based nanoparticles: exploring the origin of nanotoxicity at the molecular level. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2013; 9:1546-1556. [PMID: 23038664 DOI: 10.1002/smll.201201381] [Citation(s) in RCA: 97] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/20/2012] [Indexed: 06/01/2023]
Abstract
The widespread application of nanomaterials has spurred an interest in the study of interactions between nanoparticles and proteins due to the biosafety concerns of these nanomaterials. In this review, a summary is presented of some of the recent studies on this important subject, especially on the interactions of proteins with carbon nanotubes (CNTs) and metallofullerenols. Two potential molecular mechanisms have been proposed for CNTs' inhibition of protein functions. The driving forces of CNTs' adsorption onto proteins are found to be mainly hydrophobic interactions and the so-called π-π stacking between CNTs' carbon rings and proteins' aromatic residues. However, there is also recent evidence showing that endohedral metallofullerenol Gd@C82 (OH)22 can be used to inhibit tumor growth, thus acting as a potential nanomedicine. These recent findings have provided a better understanding of nanotoxicity at the molecular level and also suggested therapeutic potential by using nanoparticles' cytotoxicity against cancer cells.
Collapse
Affiliation(s)
- Guanghong Zuo
- Shanghai Institute of Applied Physics, Chinese Academy of Sciences, PO Box 800-204, Shanghai 201800, China
| | | | | | | | | |
Collapse
|
192
|
Ribeiro J, DaBoit K, Flores D, Kronbauer MA, Silva LFO. Extensive FE-SEM/EDS, HR-TEM/EDS and ToF-SIMS studies of micron- to nano-particles in anthracite fly ash. THE SCIENCE OF THE TOTAL ENVIRONMENT 2013; 452-453:98-107. [PMID: 23500403 DOI: 10.1016/j.scitotenv.2013.02.010] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/25/2012] [Revised: 02/04/2013] [Accepted: 02/05/2013] [Indexed: 06/01/2023]
Abstract
The generation of anthropogenic carbonaceous matter and mixed crystalline/amorphous mineral ultrafine/nano-particles in the 1 to 100 nm size range by worldwide coal power plants represents serious environmental problems due to their potential hazards. Coal fly ash (CFA) that resulted from anthracite combustion in a Portuguese thermal power plant was studied in this work. The physico-chemical characterization of ultrafine/nano-particles present in the CFA samples and their interaction with environment are the aim of this study. The methodologies applied for this work were field emission scanning electron microscopy (FE-SEM) with energy dispersive X-ray spectroscopy (EDS), high-resolution transmission electron microscopy with energy dispersive X-ray spectroscopy (HR-TEM/EDS) and time of flight secondary ion mass spectrometry (ToF-SIMS). Some hazardous volatile elements, C, N, S and Hg contents were also determined in the studied samples. Generally, the CFA samples comprise carbonaceous, glassy and metallic solid spheres with some containing mixed amorphous/crystalline phases. The EDS analysis coupled with the FE-SEM and HR-TEM observations of the fly ash particles with 100 to 0.1 nm demonstrates that these materials contain a small but significant proportion of encapsulated HVEs. In addition, the presence of abundant multi-walled carbon nanotubes (MWCNTs) and amorphous carbon particles, both containing hazardous volatile elements (HVEs), was also evidenced by the FE-SEM/EDS and HR-TEM/EDS analysis. A wide range of organic and inorganic compounds was determined by chemical maps obtained in ToF-SIMS analysis.
Collapse
Affiliation(s)
- Joana Ribeiro
- Centro de Geologia, Universidade do Porto, Porto, Portugal
| | | | | | | | | |
Collapse
|
193
|
Yan L, Li G, Zhang S, Sun F, Huang X, Zhang Q, Dai L, Lu F, Liu Y. Cytotoxicity and genotoxicity of multi-walled carbon nanotubes with human ocular cells. ACTA ACUST UNITED AC 2013. [DOI: 10.1007/s11434-013-5800-8] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
194
|
Ono-Ogasawara M, Takaya M, Kubota H, Shinohara Y, Koda S, Akiba E, Tsuruoka S, Myojo T. Approach to the Exposure Assessment of MWCNT by Considering Size Distribution and Oxidation Temperature of Elemental Carbon. ACTA ACUST UNITED AC 2013. [DOI: 10.1088/1742-6596/429/1/012004] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
195
|
Tsuruoka S, Takeuchi K, Koyama K, Noguchi T, Endo M, Tristan F, Terrones M, Matsumoto H, Saito N, Usui Y, Porter DW, Castranova V. ROS evaluation for a series of CNTs and their derivatives using an ESR method with DMPO. ACTA ACUST UNITED AC 2013; 429. [PMID: 26300949 DOI: 10.1088/1742-6596/429/1/012029] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Carbon nanotubes (CNTs) are important materials in advanced industries. It is a concern that pulmonary exposure to CNTs may induce carcinogenic responses. It has been recently reported that CNTs scavenge ROS though non-carbon fibers generate ROS. A comprehensive evaluation of ROS scavenging using various kinds of CNTs has not been demonstrated well. The present work specifically investigates ROS scavenging capabilities with a series of CNTs and their derivatives that were physically treated, and with the number of commercially available CNTs. CNT concentrations were controlled at 0.2 through 0.6 wt%. The ROS scavenging rate was measured by ESR with DMPO. Interestingly, the ROS scavenging rate was not only influenced by physical treatments, but was also dependent on individual manufacturing methods. Ratio of CNTs to DMPO/ hydrogen peroxide is a key parameter to obtain appropriate ROS quenching results for comparison of CNTs. The present results suggest that dangling bonds are not a sole factor for scavenging, and electron transfer on the CNT surface is not clearly determined to be the sole mechanism to explain ROS scavenging.
Collapse
Affiliation(s)
- S Tsuruoka
- Shinshu University, Research Center for Exotic Nanocarbons, 4-17-1 Wakasato, Nagano, Japan
| | - K Takeuchi
- Shinshu University, Faculty of Engineering, Research Center for Exotic Nanocarbons, 4-17-1 Wakasato, Nagano, Japan
| | - K Koyama
- Shinshu University, Faculty of Engineering, Research Center for Exotic Nanocarbons, 4-17-1 Wakasato, Nagano, Japan
| | - T Noguchi
- Shinshu University, Research Center for Exotic Nanocarbons, 4-17-1 Wakasato, Nagano, Japan
| | - M Endo
- Shinshu University, Research Center for Exotic Nanocarbons, 4-17-1 Wakasato, Nagano, Japan
| | - F Tristan
- Shinshu University, Research Center for Exotic Nanocarbons, 4-17-1 Wakasato, Nagano, Japan
| | - M Terrones
- Shinshu University, Research Center for Exotic Nanocarbons, 4-17-1 Wakasato, Nagano, Japan
| | - H Matsumoto
- Department of Organic and Polymeric Materials Tokyo Institute of Technology, 2-12-1 Ookayama, Meguro-ku, Tokyo, JAPAN
| | - N Saito
- Department of Applied Physical Therapy, Shinshu University, School of Health Sciences, 3-1-1 Asahi, Matsumoto, Nagano, Japan
| | - Y Usui
- Shinshu University, Faculty of Engineering, Research Center for Exotic Nanocarbons, 4-17-1 Wakasato, Nagano, Japan
| | - D W Porter
- National Institute for Occupational Safety and Health, Morgantown, WV, USA
| | - V Castranova
- National Institute for Occupational Safety and Health, Morgantown, WV, USA
| |
Collapse
|
196
|
Treumann S, Ma-Hock L, Gröters S, Landsiedel R, van Ravenzwaay B. Additional histopathologic examination of the lungs from a 3-month inhalation toxicity study with multiwall carbon nanotubes in rats. Toxicol Sci 2013; 134:103-10. [PMID: 23570993 DOI: 10.1093/toxsci/kft089] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
For hazard assessment of multiwalled carbon nanotubes (MWCNTs), a 90-day inhalation toxicity study has been performed with Nanocyl NC 7000 in accordance with OECD 413 test guideline. MWCNTs produced no systemic toxicity. However, increased lung weights, multifocal granulomatous inflammation, diffuse histiocytic and neutrophilic infiltrates, and intra-alveolar lipoproteinosis were observed in lung and lung-associated lymph nodes at 0.5 and 2.5mg/m(3). Additional investigations of the lungs were performed, including special stains for examination of connective tissue, and electron microscopy was performed to determine the location of the MWCNTs. The alveolar walls revealed no increase of collagen fibers, whereas within the microgranulomas a slight increase of collagen fibers was observed. The pleura did not reveal any increase in collagen fibers. Only a slight increase in reticulin fibers in the alveolar walls in animals of the 0.5 and 2.5mg/m(3) concentration group was noted. In the 0.1mg/m(3) group, the only animal revealing minimal granulomas exhibited a minimal increase in collagen within the granuloma. No increase in reticulin was observed. Electron microscopy demonstrated entangled MWCNTs within alveolar macrophages. Occasionally electron dense particles/detritus were observed within membrane-bound vesicles (interpreted as phagosomes), which could represent degraded MWCNTs. If so, MWCNTs were degradable by alveolar macrophages and not persistent within the lung. Inhalation of MWCNTs caused granulomatous inflammation within the lung parenchyma but not the pleura in any of the concentration groups. Thus, there are some similarities to effects caused by inhaled asbestos, but the hallmark effects, namely pleural inflammation and/or fibrosis leading to mesotheliomas, are absent.
Collapse
Affiliation(s)
- Silke Treumann
- Experimental Toxicology and Ecology, BASF SE, Ludwigshafen, Germany
| | | | | | | | | |
Collapse
|
197
|
Hirth S, Cena L, Cox G, Tomović Ž, Peters T, Wohlleben W. Scenarios and methods that induce protruding or released CNTs after degradation of nanocomposite materials. JOURNAL OF NANOPARTICLE RESEARCH : AN INTERDISCIPLINARY FORUM FOR NANOSCALE SCIENCE AND TECHNOLOGY 2013; 15:1504. [PMID: 23596358 PMCID: PMC3625415 DOI: 10.1007/s11051-013-1504-x] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/19/2012] [Accepted: 02/10/2013] [Indexed: 05/21/2023]
Abstract
ABSTRACT Nanocomposite materials may be considered as a low-risk application of nanotechnology, if the nanofillers remain embedded throughout the life-cycle of the products in which they are embedded. We hypothesize that release of free CNTs occurs by a combination of mechanical stress and chemical degradation of the polymer matrix. We experimentally address limiting cases: Mechanically released fragments may show tubular protrusions on their surface. Here we identify these protrusions unambiguously as naked CNTs by chemically resolved microscopy and a suitable preparation protocol. By size-selective quantification of fragments we establish as a lower limit that at least 95 % of the CNTs remain embedded. Contrary to classical fiber composite approaches, we link this phenomenon to matrix materials with only a few percent elongation at break, predicting which materials should still cover their CNT nanofillers after machining. Protruding networks of CNTs remain after photochemical degradation of the matrix, and we show that it takes the worst case combinations of weathering plus high-shear wear to release free CNTs in the order of mg/m2/year. Synergy of chemical degradation and mechanical energy input is identified as the priority scenario of CNT release, but its lab simulation by combined methods is still far from real-world validation.
Collapse
Affiliation(s)
| | | | | | - Željko Tomović
- BASF Polyurethanes GmbH, GMU/UE, Elastogranstrasse 60, 49448 Lemfoerde, Germany
| | | | | |
Collapse
|
198
|
Morimoto Y, Horie M, Kobayashi N, Shinohara N, Shimada M. Inhalation toxicity assessment of carbon-based nanoparticles. Acc Chem Res 2013; 46:770-81. [PMID: 22574947 DOI: 10.1021/ar200311b] [Citation(s) in RCA: 78] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Although the demand for nanomaterials has grown, researchers have not conclusively determined the effects of nanomaterials on the human body. To understand the effects of nanomaterials on occupational health, we need to estimate the respiratory toxicity of nanomaterials through inhalation studies, intratracheal instillation studies, and pharyngeal aspiration studies. The discrepancies observed among these studies tend to result from differences in the physiochemical properties of nanomaterials, such as aggregation and dispersion. Therefore, in all toxicity studies, identification of the physicochemical properties of nanomaterials is essential. This Account reviews the inhalation toxicity of manufactured nanomaterials and compares them with inhalation and intratracheal instillation studies of well-characterized fullerene and carbon nanotubes. In many reports, pulmonary inflammation and injury served as pulmonary endpoints for the inhalation toxicity. To assess pulmonary inflammation, we examined neutrophil and macrophage infiltration in the alveolar and/or interstitial space, and the expression of the neutrophil and/or monocyte chemokines. We also reported the release of lactate dehydrogenase (LDH) and alkaline phosphatase (ALP) in the bronchoalveolar lavage fluid (BALF), the expression of oxidative stress-related genes characteristic of lung injury, and the presence of granulomatous lesion and pulmonary fibrosis. In the inhalation and intratracheal instillation studies of well-characterized fullerenes, exposure to fullerene did not induce pulmonary inflammation or transient inflammation. By contrast, in an inhalation study, a high concentration of multiwall carbon nanotubes (MWCNTs) and single-wall carbon nanotubes (SWCNTs) induced neutrophil inflammation or granulomatous formations in the lung, and intratracheal instillation of MWCNTs and SWCNTs induced persistent inflammation in the lung. Among the physicochemical properties of carbon nanotubes, the increased surface area is associated with inflammatory activity as measured by the increase in the rate of neutrophils measured in bronchoalveolar lavage fluid. Metal impurities such as iron and nickel enhanced the pulmonary toxicity of carbon nanotubes, and SWCNTs that included an amorphous carbon induced multifocal granulomas in the lung while purer SWCNTs did not. The aggregation state also affects pulmonary response: Exposure to well-dispersed carbon nanotubes led to the thickening of the alveolar wall and fewer granulomatous lesions in the lung, while agglomerated carbon nanotubes produced granulomatous inflammation. The values of the acceptable exposure concentration in some countries were based on the data of subacute and subchronic inhalation and intratracheal instillation studies of well-characterized fullerene and carbon nanotubes. In Japan, the acceptable exposure concentration of fullerene is 0.39 mg/m³. In Europe, the proposal concentration is 44.4 μg/m³ for acute toxicity and 0.27 μg/m³ for chronic toxicity. The proposal acceptable exposure concentrations of carbon nanotubes are 0.03, 0.05, and 0.007 mg/m³ in Japan, Europe, and the United States, respectively.
Collapse
Affiliation(s)
- Yasuo Morimoto
- Institute of Industrial Ecological Sciences, University of Occupational and Environmental Health (UOEH), Japan
| | - Masanori Horie
- Institute of Industrial Ecological Sciences, University of Occupational and Environmental Health (UOEH), Japan
| | | | - Naohide Shinohara
- Research Institute of Science for Safety and Sustainability, National Institute of Advanced Industrial Science and Technology (AIST), Japan
| | - Manabu Shimada
- Graduate School of Engineering, Hiroshima University, Japan
| |
Collapse
|
199
|
Castranova V, Schulte PA, Zumwalde RD. Occupational nanosafety considerations for carbon nanotubes and carbon nanofibers. Acc Chem Res 2013; 46:642-9. [PMID: 23210709 PMCID: PMC4690205 DOI: 10.1021/ar300004a] [Citation(s) in RCA: 92] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Carbon nanotubes (CNTs) are carbon atoms arranged in a crystalline graphene lattice with a tubular morphology. CNTs exhibit high tensile strength, possess unique electrical properties, are durable, and can be functionalized. These properties allow applications as structural materials, in electronics, as heating elements, in batteries, in the production of stain-resistant fabric, for bone grafting and dental implants, and for targeted drug delivery. Carbon nanofibers (CNFs) are strong, flexible fibers that are currently used to produce composite materials. Agitation can lead to aerosolized CNTs and CNFs, and peak airborne particulate concentrations are associated with workplace activities such as weighing, transferring, mixing, blending, or sonication. Most airborne CNTs or CNFs found in workplaces are loose agglomerates of micrometer diameter. However, due to their low density, they linger in workplace air for a considerable time, and a large fraction of these structures are respirable. In rat and mouse models, pulmonary exposure to single-walled carbon nanotubes (SWCNTs), multi-walled carbon nanotubes (MWCNTs), or CNFs causes the following pulmonary reactions: acute pulmonary inflammation and injury, rapid and persistent formation of granulomatous lesions at deposition sites of large CNT agglomerates, and rapid and progressive alveolar interstitial fibrosis at deposition sites of more dispersed CNT or CNF structures. Pulmonary exposure to SWCNTs can induce oxidant stress in aortic tissue and increases plaque formation in an atherosclerotic mouse model. Pulmonary exposure to MWCNTs depresses the ability of coronary arterioles to respond to dilators. These cardiovascular effects may result from neurogenic signals from sensory irritant receptors in the lung. Pulmonary exposure to MWCNTs also upregulates mRNA for inflammatory mediators in selected brain regions, and pulmonary exposure to SWCNTs upregulates the baroreceptor reflex. In addition, pulmonary exposure to MWCNTs may induce levels of inflammatory mediators in the blood, which may affect the cardiovascular system. Intraperitoneal instillation of MWCNTs in mice has been associated with abdominal mesothelioma. MWCNTs deposited in the distal alveoli can migrate to the intrapleural space, and MWCNTs injected in the intrapleural space can cause lesions at the parietal pleura. However, further studies are required to determine whether pulmonary exposure to MWCNTs can induce pleural lesions or mesothelioma. In light of the anticipated growth in the production and use of CNTs and CNFs, worker exposure is possible. Because pulmonary exposure to CNTs and CNFs causes inflammatory and fibrotic reactions in the rodent lung, adverse health effects in workers represent a concern. NIOSH has conducted a risk assessment using available animal exposure-response data and is developing a recommended exposure limit for CNTs and CNFs. Evidence indicates that engineering controls and personal protective equipment can significantly decrease workplace exposure to CNTs and CNFs. Considering the available data on health risks, it appears prudent to develop prevention strategies to minimize workplace exposure. These strategies would include engineering controls (enclosure, exhaust ventilation), worker training, administrative controls, implementation of good handling practices, and the use of personal protective equipment (such as respirators) when necessary. NIOSH has published a document containing recommendations for the safe handling of nanomaterials.
Collapse
Affiliation(s)
- Vincent Castranova
- National Institute for Occupational Safety and Health, Morgantown, WV 26505, USA.
| | | | | |
Collapse
|
200
|
Chen BT, Schwegler-Berry D, McKinney W, Stone S, Cumpston JL, Friend S, Porter DW, Castranova V, Frazer DG. Multi-walled carbon nanotubes: sampling criteria and aerosol characterization. Inhal Toxicol 2013; 24:798-820. [PMID: 23033994 DOI: 10.3109/08958378.2012.720741] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
This study intends to develop protocols for sampling and characterizing multi-walled carbon nanotube (MWCNT) aerosols in workplaces or during inhalation studies. Manufactured dry powder containing MWCNT's, combined with soot and metal catalysts, form complex morphologies and diverse shapes. The aerosols, examined in this study, were produced using an acoustical generator. Representative samples were collected from an exposure chamber using filters and a cascade impactor for microscopic and gravimetric analyses. Results from filters showed that a density of 0.008-0.10 particles per µm² filter surface provided adequate samples for particle counting and sizing. Microscopic counting indicated that MWCNT's, resuspended at a concentration of 10 mg/m³, contained 2.7 × 10⁴ particles/cm³. Each particle structure contained an average of 18 nanotubes, resulting in a total of 4.9 × 10⁵ nanotubes/cm³. In addition, fibrous particles within the aerosol had a count median length of 3.04 µm and a width of 100.3 nm, while the isometric particles had a count median diameter of 0.90 µm. A combination of impactor and microscopic measurements established that the mass median aerodynamic diameter of the mixture was 1.5 µm. It was also determined that the mean effective density of well-defined isometric particles was between 0.71 and 0.88 g/cm³, and the mean shape factor of individual nanotubes was between 1.94 and 2.71. The information obtained from this study can be used for designing animal inhalation exposure studies and adopted as guidance for sampling and characterizing MWCNT aerosols in workplaces. The measurement scheme should be relevant for any carbon nanotube aerosol.
Collapse
Affiliation(s)
- Bean T Chen
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV 26505-2888, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|