1
|
Elhassan MM, Mahmoud AM, Hegazy MA, Mowaka S, Bell JG. New trends in potentiometric sensors: From design to clinical and biomedical applications. Talanta 2025; 287:127623. [PMID: 39893726 DOI: 10.1016/j.talanta.2025.127623] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2024] [Revised: 01/10/2025] [Accepted: 01/22/2025] [Indexed: 02/04/2025]
Abstract
Potentiometry, a well-established electrochemical technique, provides a powerful and versatile method for the sensitive and selective measurement of a variety of analytes by measuring the potential difference between two electrodes, allowing for a direct and rapid readout of ion concentrations. This makes it a valuable tool in a variety of applications including industry, agriculture, forensics, medical, environmental assessment, and pharmaceutical drug analysis, therefore it has received significant attention from the scientific community. Their broad implementation in sensing applications arises through their many benefits, including ease of design, fabrication, and modification; rapid response time; high selectivity; suitability for use with colored and/or turbid solutions; and potential for integration into embedded systems interfaces. Owing to these advantages and diverse applicability, sustained research and development in the field has resulted in the emergence of several notable trends in the field. 3D printing is the most recent technique used in potentiometry which offers many benefits such as improved flexibility and precision in the manufacturing of ion-selective electrodes and rapid prototyping decreases the time needed during optimization of important electrochemical parameters. Additionally, paper-based sensors are cost-effective and versatile platforms for in-field (point-of-care, POC) analysis, permitting rapid determination of a variety of analytes. One of the most interesting applications of potentiometry are wearable sensors which allow for the continuous monitoring of biomarkers, electrolytes and even pharmaceuticals, especially those with a narrow therapeutic index. Herein this review, we discuss several recent trends in potentiometric sensors since 2010, including 3D printing, paper-based devices, and other emerging techniques and the translation of potentiometric systems to wearable devices for the determination of ionic species or pharmaceuticals in biological fluids paving the way to various clinical and biomedical uses.
Collapse
Affiliation(s)
- Manar M Elhassan
- Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, The British University in Egypt, El-Sherouk City, 11837, Egypt
| | - Amr M Mahmoud
- Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Kasr El Aini, Cairo, 11562, Egypt.
| | - Maha A Hegazy
- Pharmaceutical Chemistry Department, Faculty of Pharmacy, Future University in Egypt, Cairo, 11835, Egypt
| | - Shereen Mowaka
- Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, The British University in Egypt, El-Sherouk City, 11837, Egypt; Analytical Chemistry Department, Faculty of Pharmacy, Helwan University, Ein Helwan, Cairo, Egypt
| | - Jeffrey G Bell
- Department of Chemistry, Washington State University, Pullman, WA, 99163, USA.
| |
Collapse
|
2
|
Vu C, Yan J, de Jong AM, Prins MWJ. How Highly Heterogeneous Sensors with Single-Molecule Resolution can Result in Robust Continuous Monitoring Over Long Time Spans. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2025; 12:e2412181. [PMID: 39716982 PMCID: PMC11831471 DOI: 10.1002/advs.202412181] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/30/2024] [Revised: 11/25/2024] [Indexed: 12/25/2024]
Abstract
Biomolecular sensors with single-molecule resolution are composed of multitudes of transducers that measure state changes related to single-molecular binding and unbinding events. Conventionally, signals are aggregated from many individual transducers in order to achieve sufficient statistics. However, by aggregating signals, transducer-to-transducer differences are lost and heterogeneities cannot be studied. Here, transducers with single-molecule resolution over long time spans are studied, enabling the collection of sufficient statistics from independent transducers. This allows comparisons between transducers that reveal fundamental heterogeneities in their molecular assemblies related to stochastic variations. The study is performed with biosensing by particle motion, a sensing methodology with thousands of particles that dynamically interact with a sensing surface. The signals of individual particles are studied for series of modulations of analyte concentration over 25 h. The results show large differences in individual concentration-dependent responses. Monte Carlo simulations clarify that heterogeneities can be attributed to stochastic fluctuations in the numbers of binder molecules, and that gradual changes of the response characteristics can be related to losses of molecules in the single-particle transducers. The results give insights into molecular and temporal heterogeneities of continuous transducers with single-molecule resolution and explain how sensors can be engineered to achieve robust, precise, and stable biomolecular monitoring.
Collapse
Affiliation(s)
- Chris Vu
- Department of Biomedical EngineeringEindhoven University of TechnologyEindhoven5612 AZThe Netherlands
- Institute for Complex Molecular Systems (ICMS)Eindhoven University of TechnologyEindhoven5612 AZThe Netherlands
| | - Junhong Yan
- Helia Biomonitoring BVEindhoven5612 ARThe Netherlands
| | - Arthur M. de Jong
- Institute for Complex Molecular Systems (ICMS)Eindhoven University of TechnologyEindhoven5612 AZThe Netherlands
- Department of Applied Physics and Science EducationEindhoven University of TechnologyEindhoven5612 AZThe Netherlands
| | - Menno W. J. Prins
- Department of Biomedical EngineeringEindhoven University of TechnologyEindhoven5612 AZThe Netherlands
- Institute for Complex Molecular Systems (ICMS)Eindhoven University of TechnologyEindhoven5612 AZThe Netherlands
- Helia Biomonitoring BVEindhoven5612 ARThe Netherlands
- Department of Applied Physics and Science EducationEindhoven University of TechnologyEindhoven5612 AZThe Netherlands
| |
Collapse
|
3
|
Zhang H, Cao Y, Jiang H, Zhou Q, Yang Q, Cheng L. The present and future of digital health, digital medicine, and digital therapeutics for allergic diseases. Clin Transl Allergy 2025; 15:e70020. [PMID: 39754327 DOI: 10.1002/clt2.70020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2024] [Revised: 10/24/2024] [Accepted: 12/09/2024] [Indexed: 01/06/2025] Open
Abstract
BACKGROUND Digital health, digital medicine, and digital therapeutics integrate advanced computer technologies into healthcare, aiming to improve efficiency and patient outcomes. These technologies offer innovative solutions for the management of allergic diseases, which affect a significant proportion of the global population and are increasing in prevalence. BODY: This review examines the current progress and future potential of digital health in allergic disease management. It highlights key advancements, including telehealth, mobile health (mHealth), artificial intelligence, clinical decision support systems (CDSS), and digital biomarkers, with a focus on their relevance to allergic disease management. The role of digital tools in improving treatment adherence, enabling remote care, and integrating environmental and patient data into personalized care models is discussed. Challenges such as data privacy, interoperability, and equitable access are addressed, alongside potential strategies to overcome these barriers. CONCLUSION Digital therapy will play an important role in allergic diseases, and the further development of digital therapies will effectively promote the development of clinical research, digital biomarkers, hypoallergenic environments and digital twins. More research is needed to support the progress of digital therapy for allergic diseases.
Collapse
Affiliation(s)
- He Zhang
- Department of Otolaryngology-Head and Neck Surgery, The Third Affiliated Hospital of Sun Yat-sen University, Guangzhou, China
- Department of Allergy, The Third Affiliated Hospital of Sun Yat-sen University, Guangzhou, China
- Key Laboratory of Airway Inflammatory Disease Research and Innovative Technology Translation, Guangzhou, China
| | - Yang Cao
- Department of Otorhinolaryngology & Clinical Allergy Center, The First Affiliated Hospital, Nanjing Medical University, Nanjing, China
| | - Haibo Jiang
- China Allergy-friendly Alliance (CAFA), Nanjing, China
| | - Qilin Zhou
- Department of Allergy, The Third Affiliated Hospital of Sun Yat-sen University, Guangzhou, China
| | - Qintai Yang
- Department of Otolaryngology-Head and Neck Surgery, The Third Affiliated Hospital of Sun Yat-sen University, Guangzhou, China
- Department of Allergy, The Third Affiliated Hospital of Sun Yat-sen University, Guangzhou, China
- Key Laboratory of Airway Inflammatory Disease Research and Innovative Technology Translation, Guangzhou, China
| | - Lei Cheng
- Department of Otorhinolaryngology & Clinical Allergy Center, The First Affiliated Hospital, Nanjing Medical University, Nanjing, China
- China Allergy-friendly Alliance (CAFA), Nanjing, China
- International Centre for Allergy Research, Nanjing Medical University, Nanjing, China
| |
Collapse
|
4
|
Boudry F, Durand F, Meric H, Mouakher A. The role of machine learning methods in physiological explorations of endurance trained athletes: a mini-review. Front Sports Act Living 2024; 6:1440652. [PMID: 39640504 PMCID: PMC11617143 DOI: 10.3389/fspor.2024.1440652] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2024] [Accepted: 11/04/2024] [Indexed: 12/07/2024] Open
Abstract
Endurance-trained athletes require physiological explorations that have evolved throughout the history of exercise physiology with technological advances. From the use of the Douglas bag to measure gas exchange to the development of wearable connected devices, advances in physiological explorations have enabled us to move from the classic but still widely used cardiopulmonary exercise test (CPET) to the collection of data under real conditions on outdoor endurance or ultra-endurance events. However, such explorations are often costly, time-consuming, and complex, creating a need for efficient analysis methods. Machine Learning (ML) has emerged as a powerful tool in exercise physiology, offering solutions to these challenges. Given that exercise physiologists may be unfamiliar with ML, this mini-review provides a concise overview of its relevance to the field. It introduces key ML methods, highlights their ability to predict important physiological parameters (e.g., heart rate variability and exercise-induced hypoxemia), and discusses their strengths and limitations. Finally, it outlines future directions based on the challenges identified, serving as an initial reference for physiologists exploring the application of ML in endurance exercise.
Collapse
Affiliation(s)
- Félix Boudry
- Espace Dev, Université de Perpignan Via Domitia, Perpignan, France
- UMR Espace Dev (228), Université Montpellier, IRD, Montpellier, France
| | - Fabienne Durand
- Espace Dev, Université de Perpignan Via Domitia, Perpignan, France
- UMR Espace Dev (228), Université Montpellier, IRD, Montpellier, France
| | - Henri Meric
- Espace Dev, Université de Perpignan Via Domitia, Perpignan, France
- UMR Espace Dev (228), Université Montpellier, IRD, Montpellier, France
| | - Amira Mouakher
- Espace Dev, Université de Perpignan Via Domitia, Perpignan, France
- UMR Espace Dev (228), Université Montpellier, IRD, Montpellier, France
| |
Collapse
|
5
|
Cinca-Morros S, Garcia-Rey S, Álvarez-Herms J, Basabe-Desmonts L, Benito-Lopez F. A physiological perspective of the relevance of sweat biomarkers and their detection by wearable microfluidic technology: A review. Anal Chim Acta 2024; 1327:342988. [PMID: 39266058 DOI: 10.1016/j.aca.2024.342988] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2024] [Revised: 07/15/2024] [Accepted: 07/17/2024] [Indexed: 09/14/2024]
Abstract
The great majority of published microfluidic wearable platforms for sweat sensing focus on the development of the technology to fabricate the device, the integration of sensing materials and actuators and the fluidics of sweat within the device. However, very few papers have discussed the physiological relevance of the metabolites measured using these novel approaches. In fact, some of the analytes present in sweat, which serve as biomarkers in blood, do not show a correlation with blood levels. This discrepancy can be attributed to factors such as contamination during measurements, the metabolism of sweat glands, or challenges in obtaining significant samples. The objective of this review is to present a critical and meaningful insight into the real applicability and potential use of wearable technology for improving health and sport performance. It also discusses the current limitations and future challenges of microfluidics, aiming to provide accurate information about the actual needs in this field. This work is expected to contribute to the future development of more suitable wearable microfluidic technology for health and sports science monitoring, using sweat as the biofluid for analysis.
Collapse
Affiliation(s)
- Sergi Cinca-Morros
- Microfluidics Cluster UPV/EHU, Analytical Microsystems & Materials for Lab-on-a-Chip (AMMa-LOAC) Group, Analytical Chemistry Department, University of the Basque Country UPV/EHU, Spain; Microfluidics Cluster UPV/EHU, BIOMICs Microfluidics Group, Lascaray Research Center, University of the Basque Country UPV/EHU, Vitoria-Gasteiz, Spain.
| | - Sandra Garcia-Rey
- Microfluidics Cluster UPV/EHU, Analytical Microsystems & Materials for Lab-on-a-Chip (AMMa-LOAC) Group, Analytical Chemistry Department, University of the Basque Country UPV/EHU, Spain; Microfluidics Cluster UPV/EHU, BIOMICs Microfluidics Group, Lascaray Research Center, University of the Basque Country UPV/EHU, Vitoria-Gasteiz, Spain
| | - Jesús Álvarez-Herms
- Research Group in Sports Genomics, Department of Genetics, Physical Anthropology and Animal Physiology, Faculty of Science and Technology, University of the Basque Country UPV/EHU, Leioa, Spain; PHYMOlab Research & Exercise Performance, Segovia, Spain
| | - Lourdes Basabe-Desmonts
- Microfluidics Cluster UPV/EHU, BIOMICs Microfluidics Group, Lascaray Research Center, University of the Basque Country UPV/EHU, Vitoria-Gasteiz, Spain; Basque Foundation of Science, IKERBASQUE, María Díaz Haroko Kalea, 3, 48013 Bilbao, Spain.
| | - Fernando Benito-Lopez
- Microfluidics Cluster UPV/EHU, Analytical Microsystems & Materials for Lab-on-a-Chip (AMMa-LOAC) Group, Analytical Chemistry Department, University of the Basque Country UPV/EHU, Spain.
| |
Collapse
|
6
|
Liu Y, Yang L, Cui Y. A wearable, rapidly manufacturable, stability-enhancing microneedle patch for closed-loop diabetes management. MICROSYSTEMS & NANOENGINEERING 2024; 10:112. [PMID: 39166137 PMCID: PMC11333613 DOI: 10.1038/s41378-024-00663-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/16/2023] [Revised: 10/21/2023] [Accepted: 12/02/2023] [Indexed: 08/22/2024]
Abstract
The development of a wearable, easy-to-fabricate, and stable intelligent minisystem is highly desired for the closed-loop management of diabetes. Conventional systems always suffer from large size, high cost, low stability, or complex fabrication. Here, we show for the first time a wearable, rapidly manufacturable, stability-enhancing microneedle patch for diabetes management. The patch consists of a graphene composite ink-printed sensor on hollow microneedles, a polyethylene glycol (PEG)-functionalized electroosmotic micropump integrated with the microneedles, and a printed circuit board for precise and intelligent control of the sensor and pump to detect interstitial glucose and deliver insulin through the hollow channels. Via synthesizing and printing the graphene composite ink, the sensor fabrication process is fast and the sensing electrodes are stable. The PEG functionalization enables the micropump a significantly higher stability in delivering insulin, extending its lifetime from days to weeks. The patch successfully demonstrated excellent blood glucose control in diabetic rats. This work may introduce a new paradigm for building new closed-loop systems and shows great promise for widespread use in patients with diabetes.
Collapse
Affiliation(s)
- Yiqun Liu
- School of Materials Science and Engineering, Peking University, Beijing, 100871 China
| | - Li Yang
- Renal Division, Peking University First Hospital, Peking University Institute of Nephrology, Key Laboratory of Renal Disease, Ministry of Health of China, Key Laboratory of Chronic Kidney Disease Prevention and Treatment (Peking University), Ministry of Education, Beijing, 100034 China
| | - Yue Cui
- School of Materials Science and Engineering, Peking University, Beijing, 100871 China
| |
Collapse
|
7
|
Katsumata Y, Muramoto Y, Ishida N, Takemura R, Nagashima K, Ikoma T, Kawamatsu N, Araki M, Goda A, Okawara H, Sawada T, Ichihara YK, Hattori O, Yamaoka K, Seki Y, Ryuzaki T, Ikura H, Nakashima D, Nagura T, Nakamura M, Sato K, Shiraishi Y. Sweat lactate sensor for detecting anaerobic threshold in heart failure: a prospective clinical trial (LacS-001). Sci Rep 2024; 14:18985. [PMID: 39152287 PMCID: PMC11329511 DOI: 10.1038/s41598-024-70001-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2023] [Accepted: 08/12/2024] [Indexed: 08/19/2024] Open
Abstract
A simple method for determining the anaerobic threshold in patients with heart failure (HF) is needed. This prospective clinical trial (LacS-001) aimed to investigate the safety of a sweat lactate-monitoring sensor and the correlation between lactate threshold in sweat (sLT) and ventilatory threshold (VT). To this end, we recruited 50 patients with HF and New York Heart Association functional classification I-II (mean age: 63.5 years, interquartile range: 58.0-72.0). Incremental exercise tests were conducted while monitoring sweat lactate levels using our sensor. sLT was defined as the first steep increase in lactate levels from baseline. Primary outcome measures were a correlation coefficient of ≥ 0.6 between sLT and VT, similarities as assessed by the Bland-Altman analysis, and standard deviation of the difference within 15 W. A correlation coefficient of 0.651 (95% confidence interval, 0.391-0.815) was achieved in 32/50 cases. The difference between sLT and VT was -4.9 ± 15.0 W. No comparative error was noted in the Bland-Altman plot. No device-related adverse events were reported among the registered patients. Our sweat lactate sensor is safe and accurate for detecting VT in patients with HF in clinical settings, thereby offering valuable additional information for treatment.
Collapse
Affiliation(s)
- Yoshinori Katsumata
- Institute for Integrated Sports Medicine, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan.
- Department of Cardiology, Keio University School of Medicine, Tokyo, Japan.
| | - Yuki Muramoto
- Institute for Integrated Sports Medicine, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan
| | - Noriyuki Ishida
- Biostatistics Unit, Clinical and Translational Research Center, Keio University Hospital, Tokyo, Japan
| | - Ryo Takemura
- Biostatistics Unit, Clinical and Translational Research Center, Keio University Hospital, Tokyo, Japan
| | - Kengo Nagashima
- Biostatistics Unit, Clinical and Translational Research Center, Keio University Hospital, Tokyo, Japan
| | - Takenori Ikoma
- Division of Cardiology, Internal Medicine III, Hamamatsu University School of Medicine, Hamamatsu, Japan
| | - Naoto Kawamatsu
- Department of Cardiology, Faculty of Medicine, University of Tsukuba, Tsukuba, Japan
| | - Masaru Araki
- Second Department of Internal Medicine, University of Occupational and Environmental Health, Kitakyushu, Japan
| | - Ayumi Goda
- Department of Cardiovascular Medicine, Faculty of Medicine, Kyorin University, Tokyo, Japan
| | - Hiroki Okawara
- Department of Orthopaedic Surgery, Keio University School of Medicine, Tokyo, Japan
| | - Tomonori Sawada
- Department of Orthopaedic Surgery, Keio University School of Medicine, Tokyo, Japan
| | - Yumiko Kawakubo Ichihara
- Institute for Integrated Sports Medicine, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan
- Department of Cardiology, Keio University School of Medicine, Tokyo, Japan
| | - Osamu Hattori
- Institute for Integrated Sports Medicine, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan
- Department of Cardiology, Keio University School of Medicine, Tokyo, Japan
| | - Koki Yamaoka
- Institute for Integrated Sports Medicine, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan
- Department of Cardiology, Keio University School of Medicine, Tokyo, Japan
| | - Yuta Seki
- Institute for Integrated Sports Medicine, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan
- Department of Cardiology, Keio University School of Medicine, Tokyo, Japan
| | - Toshinobu Ryuzaki
- Institute for Integrated Sports Medicine, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan
- Department of Cardiology, Keio University School of Medicine, Tokyo, Japan
| | - Hidehiko Ikura
- Institute for Integrated Sports Medicine, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan
- Department of Cardiology, Keio University School of Medicine, Tokyo, Japan
| | - Daisuke Nakashima
- Department of Orthopaedic Surgery, Keio University School of Medicine, Tokyo, Japan
| | - Takeo Nagura
- Department of Orthopaedic Surgery, Keio University School of Medicine, Tokyo, Japan
- Department of Clinical Biomechanics, Keio University School of Medicine, Tokyo, Japan
| | - Masaya Nakamura
- Department of Orthopaedic Surgery, Keio University School of Medicine, Tokyo, Japan
| | - Kazuki Sato
- Institute for Integrated Sports Medicine, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan
| | - Yasuyuki Shiraishi
- Department of Cardiology, Keio University School of Medicine, Tokyo, Japan
| |
Collapse
|
8
|
Rosa RP, Rosace G, Trovato V. Recent Advancements in Acrylic Fabric Applications: A Comprehensive Review and Future Trends. Polymers (Basel) 2024; 16:2111. [PMID: 39125138 PMCID: PMC11314402 DOI: 10.3390/polym16152111] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2024] [Revised: 07/19/2024] [Accepted: 07/23/2024] [Indexed: 08/12/2024] Open
Abstract
Acrylic fibres, as synthetic polymers, have been used extensively in the textile industry to create a wide variety of products, ranging from apparel and home furnishings to car rooftops and carbon fibres. Their widespread application is attributed to a combination of desirable properties, including a soft, wool-like texture, chemical stability, and robust mechanical characteristics. Furthermore, the chemical structure of acrylic fibres can be modified to imbue them with additional features, such as antimicrobial properties, fire resistance, conductivity, water repellency, and ultraviolet protection. This review explores the technological methods employed to functionalise acrylic fibres and discusses future trends in their development.
Collapse
Affiliation(s)
- Raphael Palucci Rosa
- Department of Engineering and Applied Sciences, University of Bergamo, Viale Marconi 5, 24044 Dalmine, BG, Italy;
| | - Giuseppe Rosace
- Department of Engineering and Applied Sciences, University of Bergamo, and Local INSTM Unit, Viale Marconi 5, 24044 Dalmine, BG, Italy;
| | - Valentina Trovato
- Department of Engineering and Applied Sciences, University of Bergamo, Viale Marconi 5, 24044 Dalmine, BG, Italy;
| |
Collapse
|
9
|
Yang G, Hong J, Park SB. Wearable device for continuous sweat lactate monitoring in sports: a narrative review. Front Physiol 2024; 15:1376801. [PMID: 38638276 PMCID: PMC11025537 DOI: 10.3389/fphys.2024.1376801] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2024] [Accepted: 03/22/2024] [Indexed: 04/20/2024] Open
Abstract
In sports science, the use of wearable technology has facilitated the development of new approaches for tracking and assessing athletes' performance. This narrative review rigorously explores the evolution and contemporary state of wearable devices specifically engineered for continuously monitoring lactate levels in sweat, an essential biomarker for appraising endurance performance. Lactate threshold tests have traditionally been integral in tailoring training intensity for athletes, but these tests have relied on invasive blood tests that are impractical outside a laboratory setting. The transition to noninvasive, real-time monitoring through wearable technology introduces an innovative approach, facilitating continuous assessment without the constraints inherent in traditional methodologies. We selected 34 products from a pool of 246 articles found through a meticulous search of articles published up to January 2024 in renowned databases: PubMed, Web of Science, and ScienceDirect. We used keywords such as "sweat lactate monitoring," "continuous lactate monitoring," and "wearable devices." The findings underscore the capabilities of noninvasive sweat lactate monitoring technologies to conduct long-term assessments over a broad range of 0-100 mM, providing a safer alternative with minimal infection risks. By enabling real-time evaluations of the lactate threshold (LT) and maximal lactate steady state (MLSS), these technologies offer athletes various device options tailored to their specific sports and preferences. This review explores the mechanisms of currently available lactate monitoring technologies, focusing on electrochemical sensors that have undergone extensive research and show promise for commercialization. These sensors employ amperometric reactions to quantify lactate levels and detect changes resulting from enzymatic activities. In contrast, colorimetric sensors offer a more straightforward and user-friendly approach by displaying lactate concentrations through color alterations. Despite significant advancements, the relationship between sweat lactate and blood lactate levels remains intricate owing to various factors such as environmental conditions and the lag between exercise initiation and sweating. Furthermore, there is a marked gap in research on sweat lactate compared to blood lactate across various sports disciplines. This review highlights the need for further research to address these shortcomings and substantiate the performance of lactate sweat monitoring technologies in a broader spectrum of sports environments. The tremendous potential of these technologies to supplant invasive blood lactate tests and pioneer new avenues for athlete management and performance optimization in real-world settings heralds a promising future for integrating sports science and wearable technology.
Collapse
Affiliation(s)
| | - Junggi Hong
- *Correspondence: Seung-Bo Park, ; Junggi Hong,
| | | |
Collapse
|
10
|
Catto A, O’Connor R, Braunscheidel KM, Kenny PJ, Shen L. FABEL: Forecasting Animal Behavioral Events with Deep Learning-Based Computer Vision. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2024:2024.03.15.584610. [PMID: 38559273 PMCID: PMC10980057 DOI: 10.1101/2024.03.15.584610] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/04/2024]
Abstract
Behavioral neuroscience aims to provide a connection between neural phenomena and emergent organism-level behaviors. This requires perturbing the nervous system and observing behavioral outcomes, and comparing observed post-perturbation behavior with predicted counterfactual behavior and therefore accurate behavioral forecasts. In this study we present FABEL, a deep learning method for forecasting future animal behaviors and locomotion trajectories from historical locomotion alone. We train an offline pose estimation network to predict animal body-part locations in behavioral video; then sequences of pose vectors are input to deep learning time-series forecasting models. Specifically, we train an LSTM network that predicts a future food interaction event in a specified time window, and a Temporal Fusion Transformer that predicts future trajectories of animal body-parts, which are then converted into probabilistic label forecasts. Importantly, accurate prediction of food interaction provides a basis for neurobehavioral intervention in the context of compulsive eating. We show promising results on forecasting tasks between 100 milliseconds and 5 seconds timescales. Because the model takes only behavioral video as input, it can be adapted to any behavioral task and does not require specific physiological readouts. Simultaneously, these deep learning models may serve as extensible modules that can accommodate diverse signals, such as in-vivo fluorescence imaging and electrophysiology, which may improve behavior forecasts and elucidate invervention targets for desired behavioral change.
Collapse
Affiliation(s)
- Adam Catto
- Nash Family Department of Neuroscience and Friedman Brain Institute, Icahn School of Medicine at Mount Sinai, New York, NY 10029, United States
| | - Richard O’Connor
- Nash Family Department of Neuroscience and Friedman Brain Institute, Icahn School of Medicine at Mount Sinai, New York, NY 10029, United States
| | - Kevin M. Braunscheidel
- Nash Family Department of Neuroscience and Friedman Brain Institute, Icahn School of Medicine at Mount Sinai, New York, NY 10029, United States
| | - Paul J. Kenny
- Nash Family Department of Neuroscience and Friedman Brain Institute, Icahn School of Medicine at Mount Sinai, New York, NY 10029, United States
| | - Li Shen
- Nash Family Department of Neuroscience and Friedman Brain Institute, Icahn School of Medicine at Mount Sinai, New York, NY 10029, United States
- Windreich Department of Artificial Intelligence and Human Health, Icahn School of Medicine at Mount Sinai, New York, NY 10029, United States
| |
Collapse
|
11
|
Antonova IV, Ivanov AI, Shavelkina MB, Poteryayev DA, Buzmakova AA, Soots RA. Engineering of graphene-based composites with hexagonal boron nitride and PEDOT:PSS for sensing applications. Phys Chem Chem Phys 2024; 26:7844-7854. [PMID: 38376373 DOI: 10.1039/d3cp05953g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/21/2024]
Abstract
A unique nanomaterial has been developed for sweat analysis, including glucose level monitoring. Simple resusable low-cost sensors from composite materials based on graphene, hexagonal boron nitride, and conductive PEDOT:PSS (poly(3,4-ethylenedioxythiophene)polystyrene sulfonate) polymer have been developed and fabricated via 2D printing on flexible substrates. The sensors were tested as biosensors using different water-based solutions. A strong increase in the current response (several orders of magnitude) was observed for aqua vapors or glucose solution vapors. This property is associated with the sorption capacity of graphene synthesized in a volume of plasma jets and thus having many active centers on the surface. The structure and properties of graphene synthesized in a plasma are different from those of graphene created by other methods. As a result, the current response for a wearable sensor is 3-5 orders of magnitude higher for the reference blood glucose concentration range of 4-14 mM. It has been found that the most promising sensor with the highest response was fabricated based on the graphene:PEDOT:PSS composite. The graphene:h-BN:PEDOT:PSS (h-BN is hexagonal boron nitride) sensors demonstrated a longer response and the highest response after the functionalization of the sensors with a glucose oxidase enzyme. The reusable wearable graphene:PEDOT:PSS glucose sensors on a paper substrate demonstrated a current response of 10-10 to 10-5 A for an operating voltage of 0.5 V and glucose range of 4-10 mM.
Collapse
Affiliation(s)
- Irina V Antonova
- Rzhanov Institute of Semiconductor Physics SB RAS, 13 Lavrentiev Av., Novosibirsk 630090, Russia.
- Department of Semiconductor Devices and Microelectronics, Novosibirsk State Technical University, 20 K. Marx Str., Novosibirsk 630073, Russia
| | - Artem I Ivanov
- Rzhanov Institute of Semiconductor Physics SB RAS, 13 Lavrentiev Av., Novosibirsk 630090, Russia.
| | - Marina B Shavelkina
- Joint Institute for High Temperatures RAS, Izhorskaya Str. 13 Bd.2, Moscow 125412, Russia
| | - Dmitriy A Poteryayev
- Rzhanov Institute of Semiconductor Physics SB RAS, 13 Lavrentiev Av., Novosibirsk 630090, Russia.
- Department of Semiconductor Devices and Microelectronics, Novosibirsk State Technical University, 20 K. Marx Str., Novosibirsk 630073, Russia
| | - Anna A Buzmakova
- Department of Semiconductor Devices and Microelectronics, Novosibirsk State Technical University, 20 K. Marx Str., Novosibirsk 630073, Russia
| | - Regina A Soots
- Rzhanov Institute of Semiconductor Physics SB RAS, 13 Lavrentiev Av., Novosibirsk 630090, Russia.
| |
Collapse
|
12
|
Li X, Lv J, Zhao J, Ling G, Zhang P. Swellable colorimetric microneedles for glucose detection based on glucose oxidase-like gold nanoparticles. Anal Chim Acta 2024; 1288:342152. [PMID: 38220286 DOI: 10.1016/j.aca.2023.342152] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2023] [Revised: 12/12/2023] [Accepted: 12/15/2023] [Indexed: 01/16/2024]
Abstract
BACKGROUND Regular blood glucose monitoring is very important for diabetic patients. The composition of skin interstitial fluid (ISF) is similar to that of blood, which can be used for daily blood sugar detection and disease care. However, most methods of ISF extraction have complicated steps, may cause skin damage, and can only extract a limited amount of ISF, resulting in low detection efficiency. Therefore, it is very necessary to develop a detection method that can not only extract a large amount of ISF safely, efficiently, and conveniently, but also realize rapid detection of glucose level in ISF. RESULTS Here, we developed a gold nanoparticle (AuNP)-based swellable colorimetric MN patch with minimally invasive sampling function and real-time ISF glucose analysis ability. The MN patch could quickly absorb a large amount of skin ISF, and 60.2 mg of ISF was extracted within 10 min in vitro. It was divided into two layers: the tip layer was embedded with AuNPs with glucose oxidase (GOx)-like activity, which catalyzed the oxidation of glucose extracted from ISF and produced hydrogen peroxide (H2O2); horseradish peroxidase (HRP) encapsulated in the backing layer catalyzed the oxidation of 3, 3', 5, 5'-tetramethylbenzidine (TMB) by H2O2 to produce oxTMB, which led to a visible color shift in the backing layer. The ISF glucose level was judged by naked eyes and further quantified by color analysis with Image J software. As a result, the colorimetric MN patch successfully identified the normal blood sugar and hyperglycemia state in vivo. SIGNIFICANCE The colorimetric MN patch combined in-situ colorimetric sensing based on AuNP nanozyme with MN patch, which detected glucose level without blood drawing, increasing patients' compliance and reducing detection steps and time. Compared with the detection methods based on natural nanozymes, our method had better stability and sensitivity to complex environments (extreme pH and high temperature, etc.) in actual detection.
Collapse
Affiliation(s)
- Xiaodan Li
- Wuya College of Innovation, Shenyang Pharmaceutical University, No. 103, Wenhua Road, Shenyang, 110016, China
| | - Jiatong Lv
- Wuya College of Innovation, Shenyang Pharmaceutical University, No. 103, Wenhua Road, Shenyang, 110016, China
| | - Jiuhong Zhao
- Wuya College of Innovation, Shenyang Pharmaceutical University, No. 103, Wenhua Road, Shenyang, 110016, China
| | - Guixia Ling
- Wuya College of Innovation, Shenyang Pharmaceutical University, No. 103, Wenhua Road, Shenyang, 110016, China.
| | - Peng Zhang
- Wuya College of Innovation, Shenyang Pharmaceutical University, No. 103, Wenhua Road, Shenyang, 110016, China.
| |
Collapse
|
13
|
Corbett J, Young JS, Tipton MJ, Costello JT, Williams TB, Walker EF, Lee BJ, Stevens CE. Molecular biomarkers for assessing the heat-adapted phenotype: a narrative scoping review. J Physiol Sci 2023; 73:26. [PMID: 37848829 PMCID: PMC10717221 DOI: 10.1186/s12576-023-00882-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Accepted: 10/03/2023] [Indexed: 10/19/2023]
Abstract
Heat acclimation/acclimatisation (HA) mitigates heat-related decrements in physical capacity and heat-illness risk and is a widely advocated countermeasure for individuals operating in hot environments. The efficacy of HA is typically quantified by assessing the thermo-physiological responses to a standard heat acclimation state test (i.e. physiological biomarkers), but this can be logistically challenging, time consuming, and expensive. A valid molecular biomarker of HA would enable evaluation of the heat-adapted state through the sampling and assessment of a biological medium. This narrative review examines candidate molecular biomarkers of HA, highlighting the poor sensitivity and specificity of these candidates and identifying the current lack of a single 'standout' biomarker. It concludes by considering the potential of multivariable approaches that provide information about a range of physiological systems, identifying a number of challenges that must be overcome to develop a valid molecular biomarker of the heat-adapted state, and highlighting future research opportunities.
Collapse
Affiliation(s)
- J Corbett
- Extreme Environments Laboratory, School of Sport Health and Exercise Sciences, University of Portsmouth, Portsmouth, UK.
| | - J S Young
- National Horizons Centre, Teesside University, Darlington, UK
| | - M J Tipton
- Extreme Environments Laboratory, School of Sport Health and Exercise Sciences, University of Portsmouth, Portsmouth, UK
| | - J T Costello
- Extreme Environments Laboratory, School of Sport Health and Exercise Sciences, University of Portsmouth, Portsmouth, UK
| | - T B Williams
- Extreme Environments Laboratory, School of Sport Health and Exercise Sciences, University of Portsmouth, Portsmouth, UK
| | - E F Walker
- Defence Science and Technology Laboratory, Porton Down, Salisbury, UK
| | - B J Lee
- Occupational and Environmental Physiology Group, Centre for Sport, Exercise and Life Sciences, Faculty of Health and Life Sciences, Coventry University, Coventry, UK
| | - C E Stevens
- Extreme Environments Laboratory, School of Sport Health and Exercise Sciences, University of Portsmouth, Portsmouth, UK
| |
Collapse
|
14
|
Coates AM, Cohen JN, Burr JF. Investigating sensor location on the effectiveness of continuous glucose monitoring during exercise in a non-diabetic population. Eur J Sport Sci 2023; 23:2109-2117. [PMID: 36715137 DOI: 10.1080/17461391.2023.2174452] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
The purpose of this investigation was to evaluate whether continuous glucose monitoring (CGM) sensors worn on the active muscle may provide enhanced insight into glucose control in non-diabetic participants during cycling exercise compared to traditional sensor placement on the arm. Data from 9 healthy participants (F:3) was recorded using CGM sensors on the arm (triceps brachii) and leg (vastus medialis) following 100 g glucose ingestion during 30 min experimental visits of: resting control, graded cycling, electrically stimulated quadriceps contractions, and passive whole-body heating. Finger capillary glucose was used to assess sensor accuracy. Under control conditions, the traditional arm sensor better reflected capillary glucose, with a mean absolute relative difference (MARD) of 12.4 ± 9.3% versus 18.3 ± 11.4% in the leg (P = 0.02). For the intended use during exercise, the sensor-site difference was attenuated, with similar MARDs during cycling (arm:15.5 ± 12% versus leg:16.7 ± 10.8%, P = 0.96) and quadriceps stimulation (arm:15.5 ± 14.8% versus leg:13.9 ± 9.5%, P = 0.9). At rest, glucose at the leg was consistently lower than the arm (P = 0.01); whereas, during graded cycling, the leg-glucose was lower only after maximal intensity exercise (P = 0.02). There was no difference between sensors during quadriceps stimulation (P = 0.8). Passive heating caused leg-skin temperature to increase by 3.1 ± 1.8°C versus 1.1 ± 0.72°C at the arm (P = 0.002), elevating MARD in the leg (23.5 ± 16.2%) and lowering glucose in the leg (P < 0.001). At rest, traditional placement of CGM sensors on the arm may best reflect blood glucose; however, during cycling, placement on the leg may offer greater insight to working muscle glucose concentrations, and this is likely due to greater blood-flow rather than muscle contractions.HighlightsWearing a continuous glucose monitoring (CGM) sensor on the arm may better reflect capillary glucose concentrations compared to wearing a sensor on the inner thigh at rest.With passive or active leg-muscle contractions, site-specific differences compared to capillary samples are attenuated; therefore, wearing a CGM sensor on the active-muscle during exercise may provide greater information to non-diabetic athletes regarding glucose flux at the active muscle.Discrepancies in CGM sensors worn at different sites likely primarily reflects differences in blood flow, as passive skin heating caused the largest magnitude difference between arm and leg sensor readings compared to the other experimental conditions (control, electric muscle stimulation, and cycling exercise).
Collapse
Affiliation(s)
- Alexandra M Coates
- The Human Performance and Health Research Laboratory, Department of Human Health and Nutritional Sciences, University of Guelph, Guelph, Canada
| | - Jeremy N Cohen
- The Human Performance and Health Research Laboratory, Department of Human Health and Nutritional Sciences, University of Guelph, Guelph, Canada
| | - Jamie F Burr
- The Human Performance and Health Research Laboratory, Department of Human Health and Nutritional Sciences, University of Guelph, Guelph, Canada
- Animal Science and Nutrition, University of Guelph, Guelph, Canada
| |
Collapse
|
15
|
Kerr D, Klonoff DC, Bergenstal RM, Choudhary P, Ji L. A Roadmap to an Equitable Digital Diabetes Ecosystem. Endocr Pract 2023; 29:179-184. [PMID: 36584818 DOI: 10.1016/j.eprac.2022.12.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Revised: 12/21/2022] [Accepted: 12/22/2022] [Indexed: 12/29/2022]
Abstract
OBJECTIVES Diabetes management presents a substantial burden to individuals living with the condition and their families, health care professionals, and health care systems. Although an increasing number of digital tools are available to assist with tasks such as blood glucose monitoring and insulin dose calculation, multiple persistent barriers continue to prevent their optimal use. METHODS As a guide to creating an equitable connected digital diabetes ecosystem, we propose a roadmap with key milestones that need to be achieved along the way. RESULTS During the Coronavirus 2019 pandemic, there was an increased use of digital tools to support diabetes care, but at the same time, the pandemic also highlighted problems of inequities in access to and use of these same technologies. Based on these observations, a connected diabetes ecosystem should incorporate and optimize the use of existing treatments and technologies, integrate tasks such as glucose monitoring, data analysis, and insulin dose calculations, and lead to improved and equitable health outcomes. CONCLUSIONS Development of this ecosystem will require overcoming multiple obstacles, including interoperability and data security concerns. However, an integrated system would optimize existing devices, technologies, and treatments to improve outcomes.
Collapse
Affiliation(s)
- David Kerr
- Diabetes Technology Society, Burlingame, California.
| | - David C Klonoff
- Diabetes Research Institute, Mills-Peninsula Medical Center, San Mateo, California
| | | | - Pratik Choudhary
- Leicester Diabetes Centre, University of Leicester, Leicester General Hospital, Leicester, UK
| | - Linong Ji
- Department of Endocrinology and Metabolism, Peking University People's Hospital, Beijing, China
| |
Collapse
|
16
|
Liu Y, Yu Q, Ye L, Yang L, Cui Y. A wearable, minimally-invasive, fully electrochemically-controlled feedback minisystem for diabetes management. LAB ON A CHIP 2023; 23:421-436. [PMID: 36597970 DOI: 10.1039/d2lc00797e] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Diabetes is a chronic disease affecting 10% of the population globally, and can lead to serious damage in the heart, kidneys, eyes, blood vessels or nerves. Commercial artificial closed-loop feedback systems can significantly improve diabetes management and save lives. However, they are large and expensive for users. Here, we demonstrate for the first time a wearable, minimally-invasive, fully electrochemically-controlled feedback minisystem for diabetes management. Both the working principles of the sensor and pump in the feedback system are based on electrochemical reactions. The smart minisystem was constructed based on integrating the thermoplastic polyurethane hollow microneedles with an electrochemical biosensing device on its outer layer and an electrochemical micropump facing the inner layer of the microneedles. The sensing device was constructed based on sputtering thin metal films through a shadow mask and electroplating Prussian blue on the surface of the microneedles, followed by the immobilization of glucose oxidase on the working electrode. The electrochemical micropump was constructed by sputtering the interdigital electrodes, followed by sealing with a thin elastic film, which was further integrated with the inner channels of the microneedles. Both the sensor and the pump were electrically powered. Via being controlled by a printed circuit board, the biosensing device monitored the levels of interstitial glucose continuously to drive the electrochemical pump to deliver insulin intelligently, in order to control blood glucose within the normal range. The closed-loop feedback system was studied for its capability in maintaining the blood glucose levels of diabetic rats under various physiological conditions. The utility of the intelligent feedback system was successfully demonstrated on diabetic rats for controlling the blood glucose levels within the normal range. The minisystem is wearable, small, cost-effective, precise, stable and painless. It is anticipated that this approach opens a new paradigm for the development of closed-loop diabetes minisystems and may lead to a compelling future for diabetes management.
Collapse
Affiliation(s)
- Yiqun Liu
- School of Materials Science and Engineering, Peking University, First Hospital Interdisciplinary Research Center, Peking University, Beijing 100871, P.R. China.
| | - Qi Yu
- Renal Division, Peking University First Hospital, Peking University Institute of Nephrology, Key Laboratory of Renal Disease, Ministry of Health of China, Key Laboratory of Chronic Kidney Disease Prevention and Treatment (Peking University), Ministry of Education, Beijing 100034, P.R. China.
| | - Le Ye
- Institute of Microelectronics, Peking University, Beijing 100871, P.R. China
| | - Li Yang
- Renal Division, Peking University First Hospital, Peking University Institute of Nephrology, Key Laboratory of Renal Disease, Ministry of Health of China, Key Laboratory of Chronic Kidney Disease Prevention and Treatment (Peking University), Ministry of Education, Beijing 100034, P.R. China.
| | - Yue Cui
- School of Materials Science and Engineering, Peking University, First Hospital Interdisciplinary Research Center, Peking University, Beijing 100871, P.R. China.
| |
Collapse
|
17
|
YAMAGATA T, SHIGEMORI Y. Relationship between sweat lactate secretion rate and blood lactate concentration during exercise near the lactate threshold. GAZZETTA MEDICA ITALIANA ARCHIVIO PER LE SCIENZE MEDICHE 2023. [DOI: 10.23736/s0393-3660.22.04780-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
|
18
|
Guagneli L, Mousavi Z, Sokalski T, Leito I, Bobacka J. Novel design of a planar flow-through potentiometric sensor. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.116785] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
19
|
Sahragard A, Varanusupakul P, Miró M. Interfacing liquid-phase microextraction with electrochemical detection: A critical review. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116749] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
20
|
Koutny T, Mayo M. Predicting glucose level with an adapted branch predictor. Comput Biol Med 2022; 145:105388. [DOI: 10.1016/j.compbiomed.2022.105388] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Revised: 02/22/2022] [Accepted: 03/04/2022] [Indexed: 11/15/2022]
|
21
|
Steijlen ASM, Jansen KMB, Bastemeijer J, French PJ, Bossche A. Low-Cost Wearable Fluidic Sweat Collection Patch for Continuous Analyte Monitoring and Offline Analysis. Anal Chem 2022; 94:6893-6901. [PMID: 35486709 PMCID: PMC9096792 DOI: 10.1021/acs.analchem.2c01052] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Sweat sensors allow for new unobtrusive ways to continuously monitor an athlete's performance and health status. Significant advances have been made in the optimization of sensitivity, selectivity, and durability of electrochemical sweat sensors. However, comparing the in situ performance of these sensors in detail remains challenging because standardized sweat measurement methods to validate sweat sensors in a physiological setting do not yet exist. Current collection methods, such as the absorbent patch technique, are prone to contamination and are labor-intensive, which limits the number of samples that can be collected over time for offline reference measurements. We present an easy-to-fabricate sweat collection system that allows for continuous electrochemical monitoring, as well as chronological sampling of sweat for offline analysis. The patch consists of an analysis chamber hosting a conductivity sensor and a sequence of 5 to 10 reservoirs that contain level indicators that monitor the filling speed. After testing the performance of the patch in the laboratory, elaborate physiological validation experiments (3 patch locations, 6 participants) were executed. The continuous sweat conductivity measurements were compared with laboratory [Na+] and [Cl-] measurements of the samples, and a strong linear relationship (R2 = 0.97) was found. Furthermore, sweat rate derived from ventilated capsule measurement at the three locations was compared with patch filling speed and continuous conductivity readings. As expected from the literature, sweat conductivity was linearly related to sweat rate as well. In short, a successfully validated sweat collection patch is presented that enables sensor developers to systematically validate novel sweat sensors in a physiological setting.
Collapse
Affiliation(s)
- Annemarijn S M Steijlen
- Faculty of Electrical Engineering, Mathematics & Computer Science, Delft University of Technology, Mekelweg 4, Delft 2628 CD, The Netherlands
| | - Kaspar M B Jansen
- Faculty of Industrial Design Engineering, Delft University of Technology, Landbergstraat 15, Delft 2628 CE, The Netherlands
| | - Jeroen Bastemeijer
- Faculty of Electrical Engineering, Mathematics & Computer Science, Delft University of Technology, Mekelweg 4, Delft 2628 CD, The Netherlands
| | - Paddy J French
- Faculty of Electrical Engineering, Mathematics & Computer Science, Delft University of Technology, Mekelweg 4, Delft 2628 CD, The Netherlands
| | - Andre Bossche
- Faculty of Electrical Engineering, Mathematics & Computer Science, Delft University of Technology, Mekelweg 4, Delft 2628 CD, The Netherlands
| |
Collapse
|
22
|
Ozer T, Henry CS. All-solid-state potassium-selective sensor based on carbon black modified thermoplastic electrode. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2021.139762] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
|
23
|
A touch-actuated glucose sensor fully integrated with microneedle array and reverse iontophoresis for diabetes monitoring. Biosens Bioelectron 2022; 203:114026. [PMID: 35114468 DOI: 10.1016/j.bios.2022.114026] [Citation(s) in RCA: 67] [Impact Index Per Article: 22.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2021] [Revised: 01/17/2022] [Accepted: 01/19/2022] [Indexed: 12/15/2022]
Abstract
The development of non-invasive biosensor for monitoring glucose in interstitial fluid (ISF) is still challenging, because ISF extraction through classical reverse iontophoresis (RI) is limited by low extraction flux and consistency. Here, we developed a touch-actuated biosensor for monitoring glucose in ISF. The biosensor is composed of three main components: 1) the solid microneedle array (MA) for painless skin penetration; 2) the RI unit for ISF extraction through the MA-created microchannels; and 3) the sensing unit for glucose monitoring. The sensing strategy of this biosensor is "skin penetration-RI extraction-electrochemical detection". Compared with RI extraction only, the reported skin penetration-RI extraction sampling strategy obviously increased the glucose extraction flux by ∼1.6 times not only in vitro but also in vivo. Moreover, we developed a wearable glucose monitoring system by incorporating this touch-actuated biosensor, a wireless electrochemical detector, and a smartphone application. In vivo experiments using healthy and diabetic rats revealed a high correlation between the results measured by the reported wearable system and commercially blood glucometer. This sampling strategy which combined skin penetration and RI extraction paves the way to develop wearable platforms for not only glucose monitoring but also various ISF biomarkers without the need of painful finger-stick blood sampling.
Collapse
|
24
|
Yoon S, Yoon H, Zahed MA, Park C, Kim D, Park JY. Multifunctional hybrid skin patch for wearable smart healthcare applications. Biosens Bioelectron 2022; 196:113685. [PMID: 34655969 DOI: 10.1016/j.bios.2021.113685] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Revised: 09/19/2021] [Accepted: 09/29/2021] [Indexed: 01/01/2023]
Abstract
Recent advances in wearable patches have included various sensors to monitor either physiological signs, such as the heart rate and respiration rate, or metabolites. Nevertheless, most of these have focused only on a single physiological measurement at a time, which significantly inhibits the calibration of various biological signals and diagnostic facilities. In this study, a novel multifunctional hybrid skin patch was developed for the electrochemical analysis of sweat glucose levels and simultaneous monitoring of electrocardiograms (ECGs). Furthermore, pH and temperature sensors were co-integrated onto the same patch for the calibration of the glucose biosensor to prevent inevitable inhibition and weakening of enzyme activity due to changes in the sweat pH and temperature levels. The fabricated electrochemical glucose biosensor exhibited excellent linearity (R2 = 0.9986) and sensitivity (29.10 μA mM-1 cm-2), covering the normal range of human sweat. The potentiometric pH sensor displayed a good response with an excellent sensitivity of -77.81 mV/pH and high linearity (R2 = 0.991), indicating that it can distinguish variations in the typical pH range for human sweat. Furthermore, the P, QRS complex, and T peaks in the measured ECG waveforms could be clearly distinguished, indicating the reliability of the fabricated flexible dry electrodes for continuous monitoring. The fabricated skin patch overcomes the inconvenience of the mandatory attachment of multiple patches on the human body by fully integrating all the electrochemical and electrophysiological sensors on a single patch, thus facilitating advanced glycemic control and continuous ECG monitoring for smart management of chronic diseases and healthcare applications.
Collapse
Affiliation(s)
- Sanghyuk Yoon
- Advanced Sensor and Energy Research (ASER) Laboratory, Electronic Engineering, Kwangwoon University, Seoul, Republic of Korea
| | - Hyosang Yoon
- Advanced Sensor and Energy Research (ASER) Laboratory, Electronic Engineering, Kwangwoon University, Seoul, Republic of Korea
| | - Md Abu Zahed
- Advanced Sensor and Energy Research (ASER) Laboratory, Electronic Engineering, Kwangwoon University, Seoul, Republic of Korea
| | - Chani Park
- Advanced Sensor and Energy Research (ASER) Laboratory, Electronic Engineering, Kwangwoon University, Seoul, Republic of Korea
| | - Dongkyun Kim
- Advanced Sensor and Energy Research (ASER) Laboratory, Electronic Engineering, Kwangwoon University, Seoul, Republic of Korea
| | - Jae Yeong Park
- Advanced Sensor and Energy Research (ASER) Laboratory, Electronic Engineering, Kwangwoon University, Seoul, Republic of Korea.
| |
Collapse
|
25
|
Kent JA, Hayes KL. Exercise Physiology From 1980 to 2020: Application of the Natural Sciences. KINESIOLOGY REVIEW (CHAMPAIGN, ILL.) 2021; 10:238-247. [PMID: 35464337 PMCID: PMC9022627 DOI: 10.1123/kr.2021-0024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
The field of exercise physiology has enjoyed tremendous growth in the past 40 years. With its foundations in the natural sciences, it is an interdisciplinary field that is highly relevant to human performance and health. The focus of this review is on highlighting new approaches, knowledge, and opportunities that have emerged in exercise physiology over the last four decades. Key among these is the adoption of advanced technologies by exercise physiologists to address fundamental research questions, and the expansion of research topics to range from molecular to organismal, and population scales in order to clarify the underlying mechanisms and impact of physiological responses to exercise in health and disease. Collectively, these advances have ensured the position of the field as a partner in generating new knowledge across many scientific and health disciplines.
Collapse
Affiliation(s)
- Jane A Kent
- Muscle Physiology Laboratory, Department of Kinesiology, University of Massachusetts Amherst, Amherst, Massachusetts, USA
| | - Kate L Hayes
- Muscle Physiology Laboratory, Department of Kinesiology, University of Massachusetts Amherst, Amherst, Massachusetts, USA
| |
Collapse
|
26
|
Abstract
Since ancient times, the health benefits of regular physical activity/exercise have been recognized and the classic studies of Morris and Paffenbarger provided the epidemiological evidence in support of such an association. Cardiorespiratory fitness, often measured by maximal oxygen uptake, and habitual physical activity levels are inversely related to mortality. Thus, studies exploring the biological bases of the health benefits of exercise have largely focused on the cardiovascular system and skeletal muscle (mass and metabolism), although there is increasing evidence that multiple tissues and organ systems are influenced by regular exercise. Communication between contracting skeletal muscle and multiple organs has been implicated in exercise benefits, as indeed has other interorgan "cross-talk." The application of molecular biology techniques and "omics" approaches to questions in exercise biology has opened new lines of investigation to better understand the beneficial effects of exercise and, in so doing, inform the optimization of exercise regimens and the identification of novel therapeutic strategies to enhance health and well-being.
Collapse
Affiliation(s)
- Mark Hargreaves
- Department of Anatomy & Physiology, The University of Melbourne, Melbourne, Victoria, Australia
| |
Collapse
|
27
|
Abstract
Commercially available consumer electronics in (smartwatches and wearable biosensors) are increasingly enabling acquisition of peripheral physiological and physical activity data inside and outside of laboratory settings. However, there is scant literature available for selecting and assessing the suitability of these novel devices for scientific use. To overcome this limitation, the current paper offers a framework to aid researchers in choosing and evaluating wearable technologies for use in empirical research. Our seven-step framework includes: (1) identifying signals of interest; (2) characterizing intended use cases; (3) identifying study-specific pragmatic needs; (4) selecting devices for evaluation; (5) establishing an assessment procedure; (6) performing qualitative and quantitative analyses on resulting data; and, if desired, (7) conducting power analyses to determine sample size needed to more rigorously compare performance across devices. We illustrate the application of the framework by comparing electrodermal, cardiovascular, and accelerometry data from a variety of commercial wireless sensors (Affectiva Q, Empatica E3, Empatica E4, Actiwave Cardio, Shimmer) relative to a well-validated, wired MindWare laboratory system. Our evaluations are performed in two studies (N = 10, N = 11) involving psychometrically sound, standardized tasks that include physical activity and affect induction. After applying our framework to this data, we conclude that only some commercially available consumer devices for physiological measurement are capable of wirelessly measuring peripheral physiological and physical activity data of sufficient quality for scientific use cases. Thus, the framework appears to be beneficial at suggesting steps for conducting more systematic, transparent, and rigorous evaluations of mobile physiological devices prior to deployment in studies.
Collapse
|
28
|
Karki HP, Jang Y, Jung J, Oh J. Advances in the development paradigm of biosample-based biosensors for early ultrasensitive detection of alzheimer's disease. J Nanobiotechnology 2021; 19:72. [PMID: 33750392 PMCID: PMC7945670 DOI: 10.1186/s12951-021-00814-7] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2021] [Accepted: 02/25/2021] [Indexed: 02/07/2023] Open
Abstract
This review highlights current developments, challenges, and future directions for the use of invasive and noninvasive biosample-based small biosensors for early diagnosis of Alzheimer's disease (AD) with biomarkers to incite a conceptual idea from a broad number of readers in this field. We provide the most promising concept about biosensors on the basis of detection scale (from femto to micro) using invasive and noninvasive biosamples such as cerebrospinal fluid (CSF), blood, urine, sweat, and tear. It also summarizes sensor types and detailed analyzing techniques for ultrasensitive detection of multiple target biomarkers (i.e., amyloid beta (Aβ) peptide, tau protein, Acetylcholine (Ach), microRNA137, etc.) of AD in terms of detection ranges and limit of detections (LODs). As the most significant disadvantage of CSF and blood-based detection of AD is associated with the invasiveness of sample collection which limits future strategy with home-based early screening of AD, we extensively reviewed the future trend of new noninvasive detection techniques (such as optical screening and bio-imaging process). To overcome the limitation of non-invasive biosamples with low concentrations of AD biomarkers, current efforts to enhance the sensitivity of biosensors and discover new types of biomarkers using non-invasive body fluids are presented. We also introduced future trends facing an infection point in early diagnosis of AD with simultaneous emergence of addressable innovative technologies.
Collapse
Affiliation(s)
- Hem Prakash Karki
- Department of Mechanical Design Engineering, College of Engineering, Jeonbuk National University, Jeonju, 54896, South Korea
| | - Yeongseok Jang
- Department of Mechanical Design Engineering, College of Engineering, Jeonbuk National University, Jeonju, 54896, South Korea
| | - Jinmu Jung
- Department of Mechanical Design Engineering, College of Engineering, Jeonbuk National University, Jeonju, 54896, South Korea.
- Department of Nano-bio Mechanical System Engineering, College of Engineering, Jeonbuk National University, Jeonju, 54896, South Korea.
| | - Jonghyun Oh
- Department of Mechanical Design Engineering, College of Engineering, Jeonbuk National University, Jeonju, 54896, South Korea.
- Department of Nano-bio Mechanical System Engineering, College of Engineering, Jeonbuk National University, Jeonju, 54896, South Korea.
| |
Collapse
|
29
|
García-Guzmán JJ, Pérez-Ràfols C, Cuartero M, Crespo GA. Microneedle based electrochemical (Bio)Sensing: Towards decentralized and continuous health status monitoring. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2020.116148] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
30
|
The (in)dependency of blood and sweat sodium, chloride, potassium, ammonia, lactate and glucose concentrations during submaximal exercise. Eur J Appl Physiol 2020; 121:803-816. [PMID: 33355715 PMCID: PMC7892530 DOI: 10.1007/s00421-020-04562-8] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2020] [Accepted: 11/11/2020] [Indexed: 01/06/2023]
Abstract
Purpose To reduce the need for invasive and expensive measures of human biomarkers, sweat is becoming increasingly popular in use as an alternative to blood. Therefore, the (in)dependency of blood and sweat composition has to be explored. Methods In an environmental chamber (33 °C, 65% relative humidity; RH), 12 participants completed three subsequent 20-min cycling stages to elicit three different local sweat rates (LSR) while aiming to limit changes in blood composition: at 60% of their maximum heart rate (HRmax), 70% HRmax and 80% HRmax, with 5 min of seated-rest in between. Sweat was collected from the arm and back during each stage and post-exercise. Blood was drawn from a superficial antecubital vein in the middle of each stage. Concentrations of sodium, chloride, potassium, ammonia, lactate and glucose were determined in blood plasma and sweat. Results With increasing exercise intensity, LSR, sweat sodium, chloride and glucose concentrations increased (P ≤ 0.026), while simultaneously limited changes in blood composition were elicited for these components (P ≥ 0.093). Sweat potassium, lactate and ammonia concentrations decreased (P ≤ 0.006), while blood potassium decreased (P = 0.003), and blood ammonia and lactate concentrations increased with higher exercise intensities (P = 0.005; P = 0.007, respectively). The vast majority of correlations between blood and sweat parameters were non-significant (P > 0.05), with few exceptions. Conclusion The data suggest that sweat composition is at least partly independent of blood composition. This has important consequences when targeting sweat as non-invasive alternative for blood measurements. Electronic supplementary material The online version of this article (10.1007/s00421-020-04562-8) contains supplementary material, which is available to authorized users.
Collapse
|
31
|
Lu L, Zhang J, Xie Y, Gao F, Xu S, Wu X, Ye Z. Wearable Health Devices in Health Care: Narrative Systematic Review. JMIR Mhealth Uhealth 2020; 8:e18907. [PMID: 33164904 PMCID: PMC7683248 DOI: 10.2196/18907] [Citation(s) in RCA: 185] [Impact Index Per Article: 37.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2020] [Revised: 09/22/2020] [Accepted: 09/24/2020] [Indexed: 12/14/2022] Open
Abstract
BACKGROUND With the rise of mobile medicine, the development of new technologies such as smart sensing, and the popularization of personalized health concepts, the field of smart wearable devices has developed rapidly in recent years. Among them, medical wearable devices have become one of the most promising fields. These intelligent devices not only assist people in pursuing a healthier lifestyle but also provide a constant stream of health care data for disease diagnosis and treatment by actively recording physiological parameters and tracking metabolic status. Therefore, wearable medical devices have the potential to become a mainstay of the future mobile medical market. OBJECTIVE Although previous reviews have discussed consumer trends in wearable electronics and the application of wearable technology in recreational and sporting activities, data on broad clinical usefulness are lacking. We aimed to review the current application of wearable devices in health care while highlighting shortcomings for further research. In addition to daily health and safety monitoring, the focus of our work was mainly on the use of wearable devices in clinical practice. METHODS We conducted a narrative review of the use of wearable devices in health care settings by searching papers in PubMed, EMBASE, Scopus, and the Cochrane Library published since October 2015. Potentially relevant papers were then compared to determine their relevance and reviewed independently for inclusion. RESULTS A total of 82 relevant papers drawn from 960 papers on the subject of wearable devices in health care settings were qualitatively analyzed, and the information was synthesized. Our review shows that the wearable medical devices developed so far have been designed for use on all parts of the human body, including the head, limbs, and torso. These devices can be classified into 4 application areas: (1) health and safety monitoring, (2) chronic disease management, (3) disease diagnosis and treatment, and (4) rehabilitation. However, the wearable medical device industry currently faces several important limitations that prevent further use of wearable technology in medical practice, such as difficulties in achieving user-friendly solutions, security and privacy concerns, the lack of industry standards, and various technical bottlenecks. CONCLUSIONS We predict that with the development of science and technology and the popularization of personalized health concepts, wearable devices will play a greater role in the field of health care and become better integrated into people's daily lives. However, more research is needed to explore further applications of wearable devices in the medical field. We hope that this review can provide a useful reference for the development of wearable medical devices.
Collapse
Affiliation(s)
- Lin Lu
- Department of Orthopaedic Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Jiayao Zhang
- Department of Orthopaedic Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Yi Xie
- Department of Orthopaedic Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Fei Gao
- Department of Orthopaedic Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Song Xu
- Department of Orthopaedic Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Xinghuo Wu
- Department of Orthopaedic Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Zhewei Ye
- Department of Orthopaedic Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| |
Collapse
|
32
|
Cao Q, Liang B, Mao X, Wei J, Tu T, Fang L, Ye X. A Smartwatch Integrated with a Paper‐based Microfluidic Patch for Sweat Electrolytes Monitoring. ELECTROANAL 2020. [DOI: 10.1002/elan.202060025] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Affiliation(s)
- Qingpeng Cao
- Biosensor National Special Laboratory Key Laboratory of Biomedical Engineering of Ministry of Education College of Biomedical Engineering and Instrument Science Zhejiang University Hangzhou 310027 P. R. China
| | - Bo Liang
- Biosensor National Special Laboratory Key Laboratory of Biomedical Engineering of Ministry of Education College of Biomedical Engineering and Instrument Science Zhejiang University Hangzhou 310027 P. R. China
| | - Xiyu Mao
- Biosensor National Special Laboratory Key Laboratory of Biomedical Engineering of Ministry of Education College of Biomedical Engineering and Instrument Science Zhejiang University Hangzhou 310027 P. R. China
| | - Jinwei Wei
- Biosensor National Special Laboratory Key Laboratory of Biomedical Engineering of Ministry of Education College of Biomedical Engineering and Instrument Science Zhejiang University Hangzhou 310027 P. R. China
| | - Tingting Tu
- Biosensor National Special Laboratory Key Laboratory of Biomedical Engineering of Ministry of Education College of Biomedical Engineering and Instrument Science Zhejiang University Hangzhou 310027 P. R. China
| | - Lu Fang
- College of Life Information Science and Instrument Engineering Hangzhou Dianzi University Hangzhou 310018 P. R. China
| | - Xuesong Ye
- Biosensor National Special Laboratory Key Laboratory of Biomedical Engineering of Ministry of Education College of Biomedical Engineering and Instrument Science Zhejiang University Hangzhou 310027 P. R. China
| |
Collapse
|
33
|
Malandrucco I, Russo B, Picconi F, Menduni M, Frontoni S. Glycemic Status Assessment by the Latest Glucose Monitoring Technologies. Int J Mol Sci 2020; 21:E8243. [PMID: 33153229 PMCID: PMC7663245 DOI: 10.3390/ijms21218243] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2020] [Revised: 10/29/2020] [Accepted: 11/02/2020] [Indexed: 12/12/2022] Open
Abstract
The advanced and performing technologies of glucose monitoring systems provide a large amount of glucose data that needs to be properly read and interpreted by the diabetology team in order to make therapeutic decisions as close as possible to the patient's metabolic needs. For this purpose, new parameters have been developed, to allow a more integrated reading and interpretation of data by clinical professionals. The new challenge for the diabetes community consists of promoting an integrated and homogeneous reading, as well as interpretation of glucose monitoring data also by the patient himself. The purpose of this review is to offer an overview of the glycemic status assessment, opened by the current data management provided by latest glucose monitoring technologies. Furthermore, the applicability and personalization of the different glycemic monitoring devices used in specific insulin-treated diabetes mellitus patient populations will be evaluated.
Collapse
Affiliation(s)
- Ilaria Malandrucco
- Unit of Endocrinology, Diabetes and Metabolism, S. Giovanni Calibita, Fatebenefratelli Hospital, 00186 Rome, Italy; (I.M.); (B.R.); (F.P.)
| | - Benedetta Russo
- Unit of Endocrinology, Diabetes and Metabolism, S. Giovanni Calibita, Fatebenefratelli Hospital, 00186 Rome, Italy; (I.M.); (B.R.); (F.P.)
- Department of Systems Medicine, University of Rome Tor Vergata, 00133 Rome, Italy;
| | - Fabiana Picconi
- Unit of Endocrinology, Diabetes and Metabolism, S. Giovanni Calibita, Fatebenefratelli Hospital, 00186 Rome, Italy; (I.M.); (B.R.); (F.P.)
| | - Marika Menduni
- Department of Systems Medicine, University of Rome Tor Vergata, 00133 Rome, Italy;
| | - Simona Frontoni
- Unit of Endocrinology, Diabetes and Metabolism, S. Giovanni Calibita, Fatebenefratelli Hospital, 00186 Rome, Italy; (I.M.); (B.R.); (F.P.)
- Department of Systems Medicine, University of Rome Tor Vergata, 00133 Rome, Italy;
| |
Collapse
|
34
|
Abstract
Carbon nanomaterials offer unique opportunities for the assembling of electrochemical aptasensors due to their high electroconductivity, redox activity, compatibility with biochemical receptors and broad possibilities of functionalization and combination with other auxiliary reagents. In this review, the progress in the development of electrochemical aptasensors based on carbon nanomaterials in 2016–2020 is considered with particular emphasis on the role of carbon materials in aptamer immobilization and signal generation. The synthesis and properties of carbon nanotubes, graphene materials, carbon nitride, carbon black particles and fullerene are described and their implementation in the electrochemical biosensors are summarized. Examples of electrochemical aptasensors are classified in accordance with the content of the surface layer and signal measurement mode. In conclusion, the drawbacks and future prospects of carbon nanomaterials’ application in electrochemical aptasensors are briefly discussed.
Collapse
|
35
|
Hattersley J, Wilson AJ, Gifford R, Facer-Childs J, Stoten O, Cobb R, Thake CD, Reynolds RM, Woods D, Imray C. A comparison of the metabolic effects of sustained strenuous activity in polar environments on men and women. Sci Rep 2020; 10:13912. [PMID: 32807833 PMCID: PMC7431584 DOI: 10.1038/s41598-020-70296-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2020] [Accepted: 06/24/2020] [Indexed: 01/05/2023] Open
Abstract
This study investigates differences in pre- to post-expedition energy expenditure, substrate utilisation and body composition, between the all-male Spear17 (SP-17) and all-female Ice Maiden (IM) transantarctic expeditions (IM: N = 6, 61 days, 1700 km; SP-17: N = 5, 67 days, 1750 km). Energy expenditure and substrate utilisation were measured by a standardised 36 h calorimetry protocol; body composition was determined using air displacement plethysmography. Energy balance calculation were used to assess the physical challenge. There was difference in the daily energy expenditure (IM: 4,939 kcal day−1; SP-17: 6,461 kcal day−1, p = 0.004); differences related to physical activity were small, but statistically significant (IM = 2,282 kcal day−1; SP-17 = 3,174 kcal day−1; p = 0.004). Bodyweight loss was modest (IM = 7.8%, SP-17 = 6.5%; p > 0.05) as was fat loss (IM = 30.4%, SP-17 = 40.4%; p > 0.05). Lean tissue weight change was statistically significant (IM = − 2.5%, SP-17 = + 1.0%; p = 0.05). No difference was found in resting or sleeping energy expenditure, normalised to lean tissue weight (p > 0.05); nor in energy expenditure when exercising at 80, 100 and 120 steps min−1, normalised to body weight (p > 0.05). Similarly, no difference was found in the change in normalised substrate utilisation for any of the activities (p > 0.05). Analysis suggested that higher daily energy expenditures for the men in Spear-17 was the result of higher physical demands resulting in a reduced demand for energy to thermoregulate compared to the women in Ice Maiden. The lack of differences between men and women in the change in energy expenditure and substrate utilisation, suggests no sex difference in response to exposure to extreme environments.
Collapse
Affiliation(s)
- John Hattersley
- Coventry NIHR CRF Human Metabolic Research Unit, University Hospitals Coventry and Warwickshire NHS Trust, Coventry, CV2 2DX, UK. .,School of Engineering, University of Warwick, Coventry, CV4 7AL, USA. .,Faculty of Health and Life Sciences, Coventry University, Coventry, UK.
| | - Adrian J Wilson
- Coventry NIHR CRF Human Metabolic Research Unit, University Hospitals Coventry and Warwickshire NHS Trust, Coventry, CV2 2DX, UK.,Department of Physics, University of Warwick, Coventry, CV4 7AL, UK
| | - Rob Gifford
- University/British Heart Foundation Centre for Cardiovascular Science, Queen's Medical Research Institute, University of Edinburgh, Edinburgh, UK.,Research and Clinical Innovation, Royal Centre for Defence Medicine, Birmingham, UK
| | - Jamie Facer-Childs
- Institute of Child Health, University College London, London, WC1N 1EH, UK
| | - Oliver Stoten
- Emergency Department, Royal Bournemouth Hospital, Bournemouth, BH7 7DW, UK
| | - Rinn Cobb
- Performance, Nutrition and Dietetic Consulting, pnd consulting.co.uk, Middlesbrough, UK
| | - C Doug Thake
- Faculty of Health and Life Sciences, Coventry University, Coventry, UK
| | - Rebecca M Reynolds
- University/British Heart Foundation Centre for Cardiovascular Science, Queen's Medical Research Institute, University of Edinburgh, Edinburgh, UK
| | - David Woods
- Research and Clinical Innovation, Royal Centre for Defence Medicine, Birmingham, UK.,Research Institute for Sport, Physical Activity and Leisure, Leeds Beckett University, Leeds, UK.,Northumbria and Newcastle NHS Trusts, Wansbeck General and Royal Victoria Infirmary, Newcastle, UK
| | - Chris Imray
- Coventry NIHR CRF Human Metabolic Research Unit, University Hospitals Coventry and Warwickshire NHS Trust, Coventry, CV2 2DX, UK.,Faculty of Health and Life Sciences, Coventry University, Coventry, UK.,Department of Vascular and Renal Transplant Surgery, University Hospitals Coventry and Warwickshire NHS Trust, Coventry, CV2 2DX, UK
| |
Collapse
|
36
|
Wiorek A, Parrilla M, Cuartero M, Crespo GA. Epidermal Patch with Glucose Biosensor: pH and Temperature Correction toward More Accurate Sweat Analysis during Sport Practice. Anal Chem 2020; 92:10153-10161. [PMID: 32588617 PMCID: PMC7467422 DOI: 10.1021/acs.analchem.0c02211] [Citation(s) in RCA: 86] [Impact Index Per Article: 17.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
![]()
We present an epidermal
patch for glucose analysis in sweat incorporating
for the first time pH and temperature correction according to local
dynamic fluctuations in sweat during on-body tests. This sort of correction
is indeed the main novelty of the paper, being crucial toward reliable
measurements in every sensor based on an enzymatic element whose activity
strongly depends on pH and temperature. The results herein reported
for corrected glucose detection during on-body measurements are supported
by a two-step validation protocol: with the biosensor operating off-
and on-bodily, correlating the results with UV–vis spectrometry
and/or ion chromatography. Importantly, the wearable device is a flexible
skin patch that comprises a microfluidic cell designed with a sweat
collection zone coupled to a fluidic channel in where the needed electrodes
are placed: glucose biosensor, pH potentiometric electrode and a temperature
sensor. The glucose biosensor presents a linear range of response
within the expected physiological levels of glucose in sweat (10–200
μM), and the calibration parameters are dynamically adjusted
to any change in pH and temperature during the sport practice by means
of a new “correction approach”. In addition, the sensor
displays a fast response time, appropriate selectivity, and excellent
reversibility. A total of 9 validated on-body tests are presented:
the outcomes revealed a great potential of the wearable glucose sensor
toward the provision of reliable physiological data linked to individuals
during sport activity. In particular, the developed “correction
approach” is expected to impact into the next generation of
wearable devices that digitalize physiological activities through
chemical information in a trustable manner for both sport and healthcare
applications.
Collapse
Affiliation(s)
- Alexander Wiorek
- Department of Chemistry, School of Engineering Sciences in Chemistry, Biotechnology and Health, KTH Royal Institute of Technology, Teknikringen 30, SE-100 44 Stockholm, Sweden
| | - Marc Parrilla
- Department of Chemistry, School of Engineering Sciences in Chemistry, Biotechnology and Health, KTH Royal Institute of Technology, Teknikringen 30, SE-100 44 Stockholm, Sweden
| | - María Cuartero
- Department of Chemistry, School of Engineering Sciences in Chemistry, Biotechnology and Health, KTH Royal Institute of Technology, Teknikringen 30, SE-100 44 Stockholm, Sweden
| | - Gastón A Crespo
- Department of Chemistry, School of Engineering Sciences in Chemistry, Biotechnology and Health, KTH Royal Institute of Technology, Teknikringen 30, SE-100 44 Stockholm, Sweden
| |
Collapse
|
37
|
Ho D, Quake SR, McCabe ERB, Chng WJ, Chow EK, Ding X, Gelb BD, Ginsburg GS, Hassenstab J, Ho CM, Mobley WC, Nolan GP, Rosen ST, Tan P, Yen Y, Zarrinpar A. Enabling Technologies for Personalized and Precision Medicine. Trends Biotechnol 2020; 38:497-518. [PMID: 31980301 PMCID: PMC7924935 DOI: 10.1016/j.tibtech.2019.12.021] [Citation(s) in RCA: 136] [Impact Index Per Article: 27.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2019] [Revised: 12/16/2019] [Accepted: 12/17/2019] [Indexed: 02/06/2023]
Abstract
Individualizing patient treatment is a core objective of the medical field. Reaching this objective has been elusive owing to the complex set of factors contributing to both disease and health; many factors, from genes to proteins, remain unknown in their role in human physiology. Accurately diagnosing, monitoring, and treating disorders requires advances in biomarker discovery, the subsequent development of accurate signatures that correspond with dynamic disease states, as well as therapeutic interventions that can be continuously optimized and modulated for dose and drug selection. This work highlights key breakthroughs in the development of enabling technologies that further the goal of personalized and precision medicine, and remaining challenges that, when addressed, may forge unprecedented capabilities in realizing truly individualized patient care.
Collapse
Affiliation(s)
- Dean Ho
- The N.1 Institute for Health (N.1), National University of Singapore, Singapore; The Institute for Digital Medicine (WisDM), National University of Singapore, Singapore; Department of Biomedical Engineering, NUS Engineering, National University of Singapore, Singapore; Department of Pharmacology, Yong Loo Lin School of Medicine, National University of Singapore, Singapore.
| | - Stephen R Quake
- Department of Bioengineering, Stanford University, CA, USA; Department of Applied Physics, Stanford University, CA, USA; Chan Zuckerberg Biohub, San Francisco, CA, USA
| | | | - Wee Joo Chng
- Department of Haematology and Oncology, National University Cancer Institute, National University Health System, Singapore; Cancer Science Institute of Singapore, National University of Singapore, Singapore
| | - Edward K Chow
- Department of Pharmacology, Yong Loo Lin School of Medicine, National University of Singapore, Singapore; Cancer Science Institute of Singapore, National University of Singapore, Singapore
| | - Xianting Ding
- Institute for Personalized Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Bruce D Gelb
- Mindich Child Health and Development Institute, Departments of Pediatrics and Genetics and Genomic Sciences, Icahn School of Medicine at Mount Sinai, NY, USA
| | - Geoffrey S Ginsburg
- Center for Applied Genomics and Precision Medicine, Duke University, NC, USA
| | - Jason Hassenstab
- Department of Neurology, Washington University in St. Louis, MO, USA; Psychological & Brain Sciences, Washington University in St. Louis, MO, USA
| | - Chih-Ming Ho
- Department of Mechanical Engineering, University of California, Los Angeles, CA, USA
| | - William C Mobley
- Department of Neurosciences, University of California, San Diego, CA, USA
| | - Garry P Nolan
- Department of Microbiology & Immunology, Stanford University, CA, USA
| | - Steven T Rosen
- Comprehensive Cancer Center and Beckman Research Institute, City of Hope, CA, USA
| | - Patrick Tan
- Duke-NUS Medical School, National University of Singapore, Singapore
| | - Yun Yen
- College of Medical Technology, Center of Cancer Translational Research, Taipei Cancer Center of Taipei Medical University, Taipei, Taiwan
| | - Ali Zarrinpar
- Department of Surgery, Division of Transplantation & Hepatobiliary Surgery, University of Florida, FL, USA
| |
Collapse
|
38
|
Validity of a wearable sweat rate monitor and routine sweat analysis techniques using heat acclimation. J Therm Biol 2020; 90:102577. [DOI: 10.1016/j.jtherbio.2020.102577] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2019] [Revised: 03/22/2020] [Accepted: 03/22/2020] [Indexed: 01/24/2023]
|
39
|
Physiological mechanisms determining eccrine sweat composition. Eur J Appl Physiol 2020; 120:719-752. [PMID: 32124007 PMCID: PMC7125257 DOI: 10.1007/s00421-020-04323-7] [Citation(s) in RCA: 126] [Impact Index Per Article: 25.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2019] [Accepted: 02/11/2020] [Indexed: 02/08/2023]
Abstract
Purpose The purpose of this paper is to review the physiological mechanisms determining eccrine sweat composition to assess the utility of sweat as a proxy for blood or as a potential biomarker of human health or nutritional/physiological status. Methods This narrative review includes the major sweat electrolytes (sodium, chloride, and potassium), other micronutrients (e.g., calcium, magnesium, iron, copper, zinc, vitamins), metabolites (e.g., glucose, lactate, ammonia, urea, bicarbonate, amino acids, ethanol), and other compounds (e.g., cytokines and cortisol). Results Ion membrane transport mechanisms for sodium and chloride are well established, but the mechanisms of secretion and/or reabsorption for most other sweat solutes are still equivocal. Correlations between sweat and blood have not been established for most constituents, with perhaps the exception of ethanol. With respect to sweat diagnostics, it is well accepted that elevated sweat sodium and chloride is a useful screening tool for cystic fibrosis. However, sweat electrolyte concentrations are not predictive of hydration status or sweating rate. Sweat metabolite concentrations are not a reliable biomarker for exercise intensity or other physiological stressors. To date, glucose, cytokine, and cortisol research is too limited to suggest that sweat is a useful surrogate for blood. Conclusion Final sweat composition is not only influenced by extracellular solute concentrations, but also mechanisms of secretion and/or reabsorption, sweat flow rate, byproducts of sweat gland metabolism, skin surface contamination, and sebum secretions, among other factors related to methodology. Future research that accounts for these confounding factors is needed to address the existing gaps in the literature. Electronic supplementary material The online version of this article (10.1007/s00421-020-04323-7) contains supplementary material, which is available to authorized users.
Collapse
|
40
|
García-Carmona L, Martín A, Sempionatto JR, Moreto JR, González MC, Wang J, Escarpa A. Pacifier Biosensor: Toward Noninvasive Saliva Biomarker Monitoring. Anal Chem 2019; 91:13883-13891. [DOI: 10.1021/acs.analchem.9b03379] [Citation(s) in RCA: 73] [Impact Index Per Article: 12.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Affiliation(s)
- Laura García-Carmona
- Department of NanoEngineering, University of California, San Diego, La Jolla, California 92093, United States
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, Faculty of Sciences, University of Alcalá, Alcalá de Henares, 28871 Madrid, Spain
| | - Aida Martín
- Department of NanoEngineering, University of California, San Diego, La Jolla, California 92093, United States
| | - Juliane R. Sempionatto
- Department of NanoEngineering, University of California, San Diego, La Jolla, California 92093, United States
| | - Jose R. Moreto
- Department of Aerospace Engineering, San Diego State University, San Diego, San Diego, California 92182, United States
- Department of Mechanical and Aerospace Engineering, University of California, San Diego, La Jolla, California 92093, United States
| | - María Cristina González
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, Faculty of Sciences, University of Alcalá, Alcalá de Henares, 28871 Madrid, Spain
- Chemical Research Institute “Andrés M. del Río”, University of Alcalá, Alcalá de Henares, E-28871 Madrid, Spain
| | - Joseph Wang
- Department of NanoEngineering, University of California, San Diego, La Jolla, California 92093, United States
| | - Alberto Escarpa
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, Faculty of Sciences, University of Alcalá, Alcalá de Henares, 28871 Madrid, Spain
- Chemical Research Institute “Andrés M. del Río”, University of Alcalá, Alcalá de Henares, E-28871 Madrid, Spain
| |
Collapse
|
41
|
Baker LB. Physiology of sweat gland function: The roles of sweating and sweat composition in human health. Temperature (Austin) 2019; 6:211-259. [PMID: 31608304 PMCID: PMC6773238 DOI: 10.1080/23328940.2019.1632145] [Citation(s) in RCA: 291] [Impact Index Per Article: 48.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2019] [Revised: 06/06/2019] [Accepted: 06/08/2019] [Indexed: 12/21/2022] Open
Abstract
The purpose of this comprehensive review is to: 1) review the physiology of sweat gland function and mechanisms determining the amount and composition of sweat excreted onto the skin surface; 2) provide an overview of the well-established thermoregulatory functions and adaptive responses of the sweat gland; and 3) discuss the state of evidence for potential non-thermoregulatory roles of sweat in the maintenance and/or perturbation of human health. The role of sweating to eliminate waste products and toxicants seems to be minor compared with other avenues of excretion via the kidneys and gastrointestinal tract; as eccrine glands do not adapt to increase excretion rates either via concentrating sweat or increasing overall sweating rate. Studies suggesting a larger role of sweat glands in clearing waste products or toxicants from the body may be an artifact of methodological issues rather than evidence for selective transport. Furthermore, unlike the renal system, it seems that sweat glands do not conserve water loss or concentrate sweat fluid through vasopressin-mediated water reabsorption. Individuals with high NaCl concentrations in sweat (e.g. cystic fibrosis) have an increased risk of NaCl imbalances during prolonged periods of heavy sweating; however, sweat-induced deficiencies appear to be of minimal risk for trace minerals and vitamins. Additional research is needed to elucidate the potential role of eccrine sweating in skin hydration and microbial defense. Finally, the utility of sweat composition as a biomarker for human physiology is currently limited; as more research is needed to determine potential relations between sweat and blood solute concentrations.
Collapse
Affiliation(s)
- Lindsay B. Baker
- Gatorade Sports Science Institute, PepsiCo R&D Physiology and Life Sciences, Barrington, IL, USA
| |
Collapse
|
42
|
Abstract
This paper discusses the physiological and technological concepts that might form the future of critical care medicine. Initially, we discuss the need for a personalized approach and introduce the concept of personalized physiological medicine (PPM), including (1) assessment of frailty and physiological reserve, (2) continuous assessment of organ function, (3) assessment of the microcirculation and parenchymal cells, and (4) integration of organ and cell function for continuous therapeutic feedback control. To understand the cellular basis of organ failure, we discuss the processes that lead to cell death, including necrosis, necroptosis, autophagy, mitophagy, and cellular senescence. In vivo technology is used to monitor these processes. To this end, we discuss new materials for developing in vivo biosensors and drug delivery systems. Such in vivo biosensors will define the diagnostic platform of the future ICU in vivo interacting with theragnostic drugs. In addition to pharmacological therapeutic options, placement and control of artificial organs to support or replace failing organs will be central in the ICU in vivo of the future. Remote monitoring and control of these biosensors and artificial organs will be made using adaptive physiological mathematical modeling of the critically ill patient. The current state of these developments is discussed.
Collapse
Affiliation(s)
- Can Ince
- Department of Intensive Care, Erasmus MC, University Medical Center, Rotterdam, 's-Gravendijkwal 230, 3015 CE, Rotterdam, the Netherlands.
| |
Collapse
|
43
|
Parrilla M, Ortiz-Gómez I, Cánovas R, Salinas-Castillo A, Cuartero M, Crespo GA. Wearable Potentiometric Ion Patch for On-Body Electrolyte Monitoring in Sweat: Toward a Validation Strategy to Ensure Physiological Relevance. Anal Chem 2019; 91:8644-8651. [DOI: 10.1021/acs.analchem.9b02126] [Citation(s) in RCA: 64] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Affiliation(s)
- Marc Parrilla
- Department of Chemistry, School of Engineering Science in Chemistry, Biotechnology and Health, KTH Royal Institute of Technology, Teknikringen 30, SE-100 44 Stockholm, Sweden
| | - Inmaculada Ortiz-Gómez
- Department of Chemistry, School of Engineering Science in Chemistry, Biotechnology and Health, KTH Royal Institute of Technology, Teknikringen 30, SE-100 44 Stockholm, Sweden
- Department of Analytical Chemistry, Campus Fuentenueva, Faculty of Sciences, University of Granada, 18071 Granada, Spain
| | - Rocío Cánovas
- Department of Chemistry, School of Engineering Science in Chemistry, Biotechnology and Health, KTH Royal Institute of Technology, Teknikringen 30, SE-100 44 Stockholm, Sweden
| | - Alfonso Salinas-Castillo
- Department of Analytical Chemistry, Campus Fuentenueva, Faculty of Sciences, University of Granada, 18071 Granada, Spain
| | - María Cuartero
- Department of Chemistry, School of Engineering Science in Chemistry, Biotechnology and Health, KTH Royal Institute of Technology, Teknikringen 30, SE-100 44 Stockholm, Sweden
| | - Gastón A. Crespo
- Department of Chemistry, School of Engineering Science in Chemistry, Biotechnology and Health, KTH Royal Institute of Technology, Teknikringen 30, SE-100 44 Stockholm, Sweden
| |
Collapse
|
44
|
The influence of local skin temperature on the sweat glands maximum ion reabsorption rate. Eur J Appl Physiol 2019; 119:685-695. [DOI: 10.1007/s00421-018-04059-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2018] [Accepted: 12/18/2018] [Indexed: 10/27/2022]
|
45
|
Cuartero M, Parrilla M, Crespo GA. Wearable Potentiometric Sensors for Medical Applications. SENSORS (BASEL, SWITZERLAND) 2019; 19:E363. [PMID: 30658434 PMCID: PMC6359219 DOI: 10.3390/s19020363] [Citation(s) in RCA: 64] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/03/2018] [Revised: 01/09/2019] [Accepted: 01/15/2019] [Indexed: 01/26/2023]
Abstract
Wearable potentiometric sensors have received considerable attention owing to their great potential in a wide range of physiological and clinical applications, particularly involving ion detection in sweat. Despite the significant progress in the manner that potentiometric sensors are integrated in wearable devices, in terms of materials and fabrication approaches, there is yet plenty of room for improvement in the strategy adopted for the sample collection. Essentially, this involves a fluidic sampling cell for continuous sweat analysis during sport performance or sweat accumulation via iontophoresis induction for one-spot measurements in medical settings. Even though the majority of the reported papers from the last five years describe on-body tests of wearable potentiometric sensors while the individual is practicing a physical activity, the medical utilization of these devices has been demonstrated on very few occasions and only in the context of cystic fibrosis diagnosis. In this sense, it may be important to explore the implementation of wearable potentiometric sensors into the analysis of other biofluids, such as saliva, tears and urine, as herein discussed. While the fabrication and uses of wearable potentiometric sensors vary widely, there are many common issues related to the analytical characterization of such devices that must be consciously addressed, especially in terms of sensor calibration and the validation of on-body measurements. After the assessment of key wearable potentiometric sensors reported over the last five years, with particular attention paid to those for medical applications, the present review offers tentative guidance regarding the characterization of analytical performance as well as analytical and clinical validations, thereby aiming at generating debate in the scientific community to allow for the establishment of well-conceived protocols.
Collapse
Affiliation(s)
- María Cuartero
- Department of Chemistry, KTH Royal Institute of Technology, Teknikringen 30, SE-10044 Stockholm, Sweden.
| | - Marc Parrilla
- Department of Chemistry, KTH Royal Institute of Technology, Teknikringen 30, SE-10044 Stockholm, Sweden.
| | - Gaston A Crespo
- Department of Chemistry, KTH Royal Institute of Technology, Teknikringen 30, SE-10044 Stockholm, Sweden.
| |
Collapse
|
46
|
Parrilla M, Cuartero M, Padrell Sánchez S, Rajabi M, Roxhed N, Niklaus F, Crespo GA. Wearable All-Solid-State Potentiometric Microneedle Patch for Intradermal Potassium Detection. Anal Chem 2019; 91:1578-1586. [PMID: 30543102 DOI: 10.1021/acs.analchem.8b04877] [Citation(s) in RCA: 108] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
A new analytical all-solid-state platform for intradermal potentiometric detection of potassium in interstitial fluid is presented here. Solid microneedles are modified with different coatings and polymeric membranes to prepare both the potassium-selective electrode and reference electrode needed for the potentiometric readout. These microneedle-based electrodes are fixed in an epidermal patch suitable for insertion into the skin. The analytical performances observed for the potentiometric cell (Nernstian slope, limit of detection of 10-4.9 potassium activity, linear range of 10-4.2 to 10-1.1, drift of 0.35 ± 0.28 mV h-1), together with a fast response time, adequate selectivity, and excellent reproducibility and repeatability, are appropriate for potassium analysis in interstitial fluid within both clinical and harmful levels. The potentiometric response is maintained after several insertions into animal skin, confirming the resiliency of the microneedle-based sensor. Ex vivo tests based on the intradermal detection of potassium in chicken and porcine skin demonstrate that the microneedle patch is suitable for monitoring potassium changes inside the skin. In addition, the dimensions of the microneedles modified with the corresponding layers necessary to enhance robustness and provide sensing capabilities (1000 μm length, 45° tip angle, 15 μm thickness in the tip, and 435 μm in the base) agree with the required ranges for a painless insertion into the skin. In vitro cytotoxicity experiments showed that the patch can be used for at least 24 h without any side effect for the skin cells. Overall, the developed concept constitutes important progress in the intradermal analysis of ions related to an electrolyte imbalance in humans, which is relevant for the control of certain types of diseases.
Collapse
Affiliation(s)
- Marc Parrilla
- Department of Chemistry, School of Engineering Science in Chemistry, Biochemistry and Health , KTH Royal Institute of Technology , Teknikringen 30 , SE-100 44 Stockholm , Sweden
| | - María Cuartero
- Department of Chemistry, School of Engineering Science in Chemistry, Biochemistry and Health , KTH Royal Institute of Technology , Teknikringen 30 , SE-100 44 Stockholm , Sweden
| | - Sara Padrell Sánchez
- Department of Clinical Science, Intervention and Technology , Karolinska Institutet , K 57 , SE-141 86 Stockholm , Sweden.,Division of Obstetrics and Gynecology , Karolinska Universitetssjukhuset , 14186 Stockholm , Sweden
| | - Mina Rajabi
- Department of Micro and Nanosystems, School of Electrical Engineering and Computer Science , KTH Royal Institute of Technology , Malvinas väg 10 , SE-100 44 Stockholm , Sweden
| | - Niclas Roxhed
- Department of Micro and Nanosystems, School of Electrical Engineering and Computer Science , KTH Royal Institute of Technology , Malvinas väg 10 , SE-100 44 Stockholm , Sweden
| | - Frank Niklaus
- Department of Micro and Nanosystems, School of Electrical Engineering and Computer Science , KTH Royal Institute of Technology , Malvinas väg 10 , SE-100 44 Stockholm , Sweden
| | - Gastón A Crespo
- Department of Chemistry, School of Engineering Science in Chemistry, Biochemistry and Health , KTH Royal Institute of Technology , Teknikringen 30 , SE-100 44 Stockholm , Sweden
| |
Collapse
|
47
|
|
48
|
Taj-Eldin M, Ryan C, O'Flynn B, Galvin P. A Review of Wearable Solutions for Physiological and Emotional Monitoring for Use by People with Autism Spectrum Disorder and Their Caregivers. SENSORS (BASEL, SWITZERLAND) 2018; 18:E4271. [PMID: 30518133 PMCID: PMC6308558 DOI: 10.3390/s18124271] [Citation(s) in RCA: 43] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/31/2018] [Revised: 11/30/2018] [Accepted: 12/01/2018] [Indexed: 12/28/2022]
Abstract
The goal of real-time feedback on physiological changes, stress monitoring and even emotion detection is becoming a technological reality. People in their daily life experience varying emotional states, some of which are negative and which can lead to decreased attention, decreased productivity and ultimately, reduced quality of life. Therefore, having a solution that continuously monitors the physiological signals of the person and assesses his or her emotional well-being could be a very valuable tool. This paper aims to review existing physiological and motional monitoring devices, highlight their features and compare their sensing capabilities. Such technology would be particularly useful for certain populations who experience rapidly changing emotional states such as people with autism spectrum disorder and people with intellectual disabilities. Wearable sensing devices present a potential solution that can support and complement existing behavioral interventions. This paper presents a review of existing and emerging products in the market. It reviews the literature on state-of-the-art prototypes and analyzes their usefulness, clinical validity, and discusses clinical perspectives. A small number of products offer reliable physiological internal state monitoring and may be suitable for people with Autism Spectrum Disorder (ASD). It is likely that more promising solutions will be available in the near future. Therefore, caregivers should be careful in their selection of devices that meet the care-receiver's personal needs and have strong research support for reliability and validity.
Collapse
Affiliation(s)
- Mohammed Taj-Eldin
- Tyndall National Institute, University College Cork, T12 R5CP Cork, Ireland.
| | - Christian Ryan
- School of Applied Psychology, University College Cork, T12 R5CP Cork, Ireland.
| | - Brendan O'Flynn
- Tyndall National Institute, University College Cork, T12 R5CP Cork, Ireland.
| | - Paul Galvin
- Tyndall National Institute, University College Cork, T12 R5CP Cork, Ireland.
| |
Collapse
|
49
|
Brown MS, Ashley B, Koh A. Wearable Technology for Chronic Wound Monitoring: Current Dressings, Advancements, and Future Prospects. Front Bioeng Biotechnol 2018; 6:47. [PMID: 29755977 PMCID: PMC5932176 DOI: 10.3389/fbioe.2018.00047] [Citation(s) in RCA: 92] [Impact Index Per Article: 13.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2018] [Accepted: 04/03/2018] [Indexed: 12/14/2022] Open
Abstract
Chronic non-healing wounds challenge tissue regeneration and impair infection regulation for patients afflicted with this condition. Next generation wound care technology capable of in situ physiological surveillance which can diagnose wound parameters, treat various chronic wound symptoms, and reduce infection at the wound noninvasively with the use of a closed loop therapeutic system would provide patients with an improved standard of care and an accelerated wound repair mechanism. The indicating biomarkers specific to chronic wounds include blood pressure, temperature, oxygen, pH, lactate, glucose, interleukin-6 (IL-6), and infection status. A wound monitoring device would help decrease prolonged hospitalization, multiple doctors' visits, and the expensive lab testing associated with the diagnosis and treatment of chronic wounds. A device capable of monitoring the wound status and stimulating the healing process is highly desirable. In this review, we discuss the impaired physiological states of chronic wounds and explain the current treatment methods. Specifically, we focus on improvements in materials, platforms, fabrication methods for wearable devices, and quantitative analysis of various biomarkers vital to wound healing progress.
Collapse
Affiliation(s)
- Matthew S Brown
- Department of Biomedical Engineering, State University of New York at Binghamton University, Binghamton, NY, United States
| | - Brandon Ashley
- Department of Biomedical Engineering, State University of New York at Binghamton University, Binghamton, NY, United States
| | - Ahyeon Koh
- Department of Biomedical Engineering, State University of New York at Binghamton University, Binghamton, NY, United States
| |
Collapse
|
50
|
Stacey MJ, Hill N, Woods D. Physiological monitoring for healthy military personnel. J ROY ARMY MED CORPS 2017; 164:290-292. [DOI: 10.1136/jramc-2017-000851] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2017] [Revised: 10/31/2017] [Accepted: 11/01/2017] [Indexed: 12/22/2022]
Abstract
Military employment commonly exposes personnel to strenuous physical exertion. The resulting interaction between occupational stress and individual susceptibility to illness demands careful management. This could extend to prospective identification of high physiological strain in healthy personnel, in addition to recognition and protection of vulnerable individuals. The emergence and ubiquitous uptake of ‘wearable’ physiological and medical monitoring devices might help to address this challenge, but requires that the right questions are asked in sourcing, developing, validating and applying such technologies. Issues that must be addressed include system requirements, such as the likelihood of end users deploying and using technology as intended; interpretation of data in relation to pretest probability, including the potential for false-positive results; differentiation of pathological states from normal physiology; responsibility for and consequences of acting on abnormal or unexpected results and cost-effectiveness. Ultimately, the performance of a single monitoring system, in isolation or alongside other measures, should be judged by whether any improvement is offered versus existing capabilities and at what cost to mission effectiveness.
Collapse
|